Sample records for postoperative refractive error

  1. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  2. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  3. Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation.

    PubMed

    Indaram, Maanasa; VanderVeen, Deborah K

    2018-01-01

    Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.

  4. Postoperative refraction in the second eye having cataract surgery.

    PubMed

    Leffler, Christopher T; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A

    2011-01-01

    Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry.

  5. Clinical Outcomes of an Optimized Prolate Ablation Procedure for Correcting Residual Refractive Errors Following Laser Surgery.

    PubMed

    Chung, Byunghoon; Lee, Hun; Choi, Bong Joon; Seo, Kyung Ryul; Kim, Eung Kwon; Kim, Dae Yune; Kim, Tae-Im

    2017-02-01

    The purpose of this study was to investigate the clinical efficacy of an optimized prolate ablation procedure for correcting residual refractive errors following laser surgery. We analyzed 24 eyes of 15 patients who underwent an optimized prolate ablation procedure for the correction of residual refractive errors following laser in situ keratomileusis, laser-assisted subepithelial keratectomy, or photorefractive keratectomy surgeries. Preoperative ophthalmic examinations were performed, and uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction values (sphere, cylinder, and spherical equivalent), point spread function, modulation transfer function, corneal asphericity (Q value), ocular aberrations, and corneal haze measurements were obtained postoperatively at 1, 3, and 6 months. Uncorrected distance visual acuity improved and refractive errors decreased significantly at 1, 3, and 6 months postoperatively. Total coma aberration increased at 3 and 6 months postoperatively, while changes in all other aberrations were not statistically significant. Similarly, no significant changes in point spread function were detected, but modulation transfer function increased significantly at the postoperative time points measured. The optimized prolate ablation procedure was effective in terms of improving visual acuity and objective visual performance for the correction of persistent refractive errors following laser surgery.

  6. Postoperative Refraction in the Second Eye Having Cataract Surgery

    PubMed Central

    Leffler, Christopher T.; Wilkes, Martin; Reeves, Juliana; Mahmood, Muneera A.

    2011-01-01

    Introduction. Previous cataract surgery studies assumed that first-eye predicted and observed postoperative refractions are equally important for predicting second-eye postoperative refraction. Methods. In a retrospective analysis of 173 patients having bilateral sequential phacoemulsification, multivariable linear regression was used to predict the second-eye postoperative refraction based on refractions predicted by the SRK-T formula for both eyes, the first-eye postoperative refraction, and the difference in IOL selected between eyes. Results. The first-eye observed postoperative refraction was an independent predictor of the second eye postoperative refraction (P < 0.001) and was weighted more heavily than the first-eye predicted refraction. Compared with the SRK-T formula, this model reduced the root-mean-squared (RMS) error of the predicted refraction by 11.3%. Conclusions. The first-eye postoperative refraction is an independent predictor of the second-eye postoperative refraction. The first-eye predicted refraction is less important. These findings may be due to interocular symmetry. PMID:24533181

  7. The use of a supplemental sulcus fixated IOL (HumanOptics Add-On IOL) to correct pseudophakic refractive errors.

    PubMed

    Basarir, Berna; Kaya, Vedat; Altan, Cigdem; Karakus, Sezen; Pinarci, Eylem Y; Demirok, Ahmet

    2012-01-01

    To evaluate the safety and efficacy of piggybacking with the HumanOptics Add-On intraocular lens (IOL) to correct pseudophakic refractive errors. Ten eyes of 10 patients with pseudophakic refractive errors were included in this study. All patients were targeted for a range of refraction -0.50 to +0.50 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), endothelial cell count (ECC), anterior chamber depth (ACD), the distance between intraocular lenses, and contrast sensitivity measurements under mesopic, scotopic, and scotopic with glare conditions were evaluated preoperatively and postoperatively. The mean age of the patients was 54±27 years (range 4-78). Mean follow-up time was 10.5±1.36 months (range 6-15 months). Mean diopters of implanted Add-On IOLs were -1.4±6.9 (range -12 to +9 D). Mean preoperative and postoperative UDVA was 0.133±0.12 and 0.73±0.27, respectively (p=0.0001); mean preoperative and postoperative CDVA were 0.77±0.26 and 0.79±0.27, respectively (p=0.066). Mean preoperative and postoperative ACD were 3.87±0.91 mm vs 3.58±1.05 mm, respectively (p=0.343); mean inter-IOL distance was 0.53±0.08 mm. Mean preoperative and postoperative ECC were 2455±302 and 2426±294, respectively (p=0.55). All patients were within the targeted refractive range of -0.50 D to +0.50 D. No complications were observed during the operations or postoperative follow-up period. Piggybacking with the Add-On IOL is a safe, efficient, and reliable technique to correct pseudophakic refractive errors.

  8. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery

    PubMed Central

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2015-01-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies. PMID:25663845

  9. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

    PubMed

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2014-12-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies.

  10. Patient age, refractive index of the corneal stroma, and outcomes of uneventful laser in situ keratomileusis.

    PubMed

    Patel, Sudi; Alió, Jorge L; Walewska, Anna; Amparo, Francisco; Artola, Alberto

    2013-03-01

    To determine the influence of age and the corneal stromal refractive index on the difference between the predicted and actual postoperative refractive error after laser in situ keratomileusis (LASIK) and whether the precision of outcomes could be improved by considering age and the refractive index. Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. Case series. Flaps were created using a mechanical microkeratome. The stromal refractive index was measured using a VCH-1 refractometer after flap lifting. Refractive data were obtained 1, 3, and 6 months postoperatively. Uneventful LASIK was performed in 133 eyes. The mean age, refractive index, and applied corrections were 33.4 years ± 9.49 (SD), 1.368 ± 0.006, and -2.43 ± 3.36 diopters (D), respectively. The difference between the predicted and actual postoperative refractive error = 2.315-0.021 age-1.106 refractive index (F = 3.647, r = 0.254, P=.029; n = 109) at 1 month and = 11.820-0.023 age-7.976 refractive index (F = 3.392, r = 0.261, P=.022, n = 106) at 3 months. A correlation between the actual and calculated postoperative refraction improved from r = -0.178 (P=.064; n = 75) to r = -0.418 (P<.001) after considering the true refractive index 6 months postoperatively. The predicted outcomes of LASIK can be improved by inputting the refractive index of the individual corneal stroma. Unexpected outcomes (>0.50 D) of LASIK could be avoided by considering patient age and the refractive index and by adjusting the applied correction accordingly. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Mechanisms of Corneal Pain and Implications for Postoperative Pain After Laser Correction of Refractive Errors.

    PubMed

    Garcia, Renato; de Andrade, Daniel C; Teixeira, Manoel J; Nozaki, Siro S; Bechara, Samir J

    2016-05-01

    The cornea is the target of most surgeries for refractive disorders, as myopia. It is estimated that almost 1 million patients undergo corneal refractive surgery each year in the United States. Refractive surgery includes photorefractive keratectomy (PRK) that produces intense postoperative pain. This review presents the main pain mechanisms behind PRK-related pain and the available therapeutic options for its management. Data sources included literature of cornea anatomy, treatment of PRK postoperative pain, mechanisms of corneal pain, in 3 electronic databases: Pubmed, Scopus, and Web of Science. Only double-blinded controlled trials on pain control after PRK were selected to show the endpoints, treatment, and control strategies. A total of 18 double-blind, controlled trials were identified. These studies have shown the use of topical nonsteroidal anti-inflammatory drugs, topical steroidal anti-inflammatory drugs, systemic analgesics, cold balanced saline solution, topical anesthetic, gabapentin, and morphine to treat postoperative pain in PRK. The percentage of responders has seldom been reported, and few studies allow for the formal calculation of the number necessary to treat. Postoperative intense pain after PRK laser surgery remains the main challenge to its widespread use for the correction of refractive errors.

  12. [Can the scattering of differences from the target refraction be avoided?].

    PubMed

    Janknecht, P

    2008-10-01

    We wanted to check how the stochastic error is affected by two lens formulae. The power of the intraocular lens was calculated using the SRK-II formula and the Haigis formula after eye length measurement with ultrasound and the IOL Master. Both lens formulae were partially derived and Gauss error analysis was used for examination of the propagated error. 61 patients with a mean age of 73.8 years were analysed. The postoperative refraction differed from the calculated refraction after ultrasound biometry using the SRK-II formula by 0.05 D (-1.56 to + 1.31, S. D.: 0.59 D; 92 % within +/- 1.0 D), after IOL Master biometry using the SRK-II formula by -0.15 D (-1.18 to + 1.25, S. D.: 0.52 D; 97 % within +/- 1.0 D), and after IOL Master biometry using the Haigis formula by -0.11 D (-1.14 to + 1.14, S. D.: 0.48 D; 95 % within +/- 1.0 D). The results did not differ from one another. The propagated error of the Haigis formula can be calculated according to DeltaP = square root (deltaL x (-4.206))(2) + (deltaVK x 0.9496)(2) + (DeltaDC x (-1.4950))(2). (DeltaL: error measuring axial length, DeltaVK error measuring anterior chamber depth, DeltaDC error measuring corneal power), the propagated error of the SRK-II formula according to DeltaP = square root (DeltaL x (-2.5))(2) + (DeltaDC x (-0.9))(2). The propagated error of the Haigis formula is always larger than the propagated error of the SRK-II formula. Scattering of the postoperative difference from the expected refraction cannot be avoided completely. It is possible to limit the systematic error by developing complicated formulae like the Haigis formula. However, increasing the number of parameters which need to be measured increases the dispersion of the calculated postoperative refraction. A compromise has to be found, and therefore the SRK-II formula is not outdated.

  13. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    PubMed

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  14. Relationship between postoperative refractive outcomes and cataract density: multiple regression analysis.

    PubMed

    Ueda, Tetsuo; Ikeda, Hitoe; Ota, Takeo; Matsuura, Toyoaki; Hara, Yoshiaki

    2010-05-01

    To evaluate the relationship between cataract density and the deviation from the predicted refraction. Department of Ophthalmology, Nara Medical University, Kashihara, Japan. Axial length (AL) was measured in eyes with mainly nuclear cataract using partial coherence interferometry (IOLMaster). The postoperative AL was measured in pseudophakic mode. The AL difference was calculated by subtracting the postoperative AL from the preoperative AL. Cataract density was measured with the pupil dilated using anterior segment Scheimpflug imaging (EAS-1000). The predicted postoperative refraction was calculated using the SRK/T formula. The subjective refraction 3 months postoperatively was also measured. The mean absolute prediction error (MAE) (mean of absolute difference between predicted postoperative refraction and spherical equivalent of postoperative subjective refraction) was calculated. The relationship between the MAE and cataract density, age, preoperative visual acuity, anterior chamber depth, corneal radius of curvature, and AL difference was evaluated using multiple regression analysis. In the 96 eyes evaluated, the MAE was correlated with cataract density (r = 0.37, P = .001) and the AL difference (r = 0.34, P = .003) but not with the other parameters. The AL difference was correlated with cataract density (r = 0.53, P<.0001). The postoperative refractive outcome was affected by cataract density. This should be taken into consideration in eyes with a higher density cataract. (c) 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Outcomes of LASIK and PRK in previous penetrating corneal transplant recipients.

    PubMed

    Kovoor, Timmy A; Mohamed, Engy; Cavanagh, H Dwight; Bowman, R Wayne

    2009-09-01

    To evaluate the safety and efficacy of excimer laser refractive surgery in correcting refractive error in eyes that have undergone previous penetrating keratoplasty (PK). Twenty-three keratorefractive procedures on 16 eyes from 16 consecutive subjects were evaluated between 2002 and 2008. Each patient presented a previous history of a PK with subsequent postoperative myopia and astigmatism. Keratometric value, manifest refraction, best-corrected visual acuity, uncorrected visual acuity, and complications were determined. There were a total of 14 photorefractive keratectomy (PRK) procedures performed on 11 eyes and 9 laser in situ keratomileusis (LASIK) procedures performed on 5 eyes. In the PRK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -6.22 +/- 6.23 diopter and 5.23 +/- 2.26 D, respectively. The PRK postoperative manifest refractive spherical equivalent and cylindrical error were -3.61 +/- 4.23 D (P=0.25) and 3.21 +/- 1.78 D (P=0.02), respectively. In the LASIK group, the preoperative post-PK manifest refractive spherical equivalent and cylindrical error were -3.05 +/- 3.29 D and 4.11 +/- 2.38 D, respectively. The LASIK postoperative manifest refractive spherical equivalent and cylindrical error were -1.51 +/- 2.02 D (P=0.24) and 2.08 +/- 1.26 D (P=0.03), respectively. There was a 2-line or greater improvement of uncorrected visual acuity in 8 of the 14 PRK treatments and 5 of the 9 LASIK treatments. There were two episodes of acute graft rejection. One of the episodes resolved with topical and oral corticosteroids, and the other episode required a repeat corneal transplantation. PRK and LASIK are effective tools in reducing surgically induced astigmatism after penetrating corneal transplantation in most patients in this case series. The reduction of astigmatism may allow improved contact lens or spectacle fitting to achieve best-corrected binocular visual acuity.

  16. Impact of nuclear cataract density on postoperative refractive outcome: IOL Master versus ultrasound.

    PubMed

    Ueda, Tetsuo; Taketani, Futoshi; Ota, Takeo; Hara, Yoshiaki

    2007-01-01

    To evaluate the effect of cataract density on the postoperative refractive outcome. For 59 nuclear cataract eyes, the axial length was preoperatively measured by the IOL Master (Zeiss, Germany) and ultrasound (US; UD-6000, Tomey, Japan) and the cataract density by EAS-1000 (Nidek, Japan). The prediction error was used as evaluation of the accuracy of ocular biometry. There were significant differences between IOL Master and US in the mean error (0.24 +/- 0.63 vs. 0.69 +/- 0.64 dpt, p < 0.001) and the mean absolute error (0.57 +/- 0.36 vs. 0.79 +/- 0.53 dpt, p < 0.001). The cataract density was significantly correlated with the prediction error with IOL Master (r = 0.24, p = 0.03) and US (r = 0.29, p = 0.01). Measurements with the IOL Master are slightly affected by the cataract density due to the refractive index change, but its accuracy is less affected than US. (c) 2007 S. Karger AG, Basel.

  17. Keratometry obtained by corneal mapping versus the IOLMaster in the prediction of postoperative refraction in routine cataract surgery.

    PubMed

    Dulku, Simon; Smith, Henry B; Antcliff, Richard J

    2013-01-01

    To establish whether simulated keratometry values obtained by corneal mapping (videokeratography) would provide a superior refractive outcome to those obtained by Zeiss IOLMaster (partial coherence interferometry) in routine cataract surgery. Prospective, non-randomized, single-surgeon study set at the The Royal United Hospital, Bath, UK, District General Hospital. Thirty-three patients undergoing routine cataract surgery in the absence of significant ocular comorbidity. Conventional biometry was recorded using the Zeiss IOLMaster. Postoperative refraction was calculated using the SRK/T formula and the most appropriate power of lens implanted. Preoperative keratometry values were also obtained using Humphrey Instruments Atlas Version A6 corneal mapping. Achieved refraction was compared with predicted refraction for the two methods of keratometry after the A-constants were optimized to obtain a mean arithmetic error of zero dioptres for each device. The mean absolute prediction error was 0.39 dioptres (standard deviation 0.29) for IOLMaster and 0.48 dioptres (standard deviation 0.31) for corneal mapping (P = 0.0015). Keratometry readings between the devices were highly correlated by Spearman correlation (0.97). The Bland-Altman plot demonstrated close agreement between keratometers, with a bias of 0.0079 dioptres and 95% limits of agreement of -0.48-0.49 dioptres. The IOLMaster was superior to Humphrey Atlas A6 corneal mapping in the prediction of postoperative refraction. This difference could not have been predicted from the keratometry readings alone. When comparing biometry devices, close agreement between readings should not be considered a substitute for actual postoperative refraction data. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  18. Refractive Lenticule Transplantation for Correction of Iatrogenic Hyperopia and High Astigmatism After LASIK.

    PubMed

    Lazaridis, Apostolos; Reinstein, Dan Z; Archer, Timothy J; Schulze, Stephan; Sekundo, Walter

    2016-11-01

    To design a technique for intrastromal transplantation of stromal lenticules with specific refractive power for correction of post-LASIK induced hyperopia and astigmatism. A 28-year-old patient was referred for consultation after complicated LASIK for moderate myopia and astigmatism. The refractive error of the right eye was severely overcorrected due to data entry error. Post-LASIK refraction showed high astigmatism (right eye: +6.50 -9.00 @ 84°) and corrected distance visual acuity (CDVA) of 20/32. The corneal thickness was 282 µm. A refractive lenticule transplantation was performed due to contact lens intolerance, poor visual acuity, and severe anisometropia. A toric and myopic lenticule, obtained from a donor using the femtosecond lenticule extraction technique, was implanted under the flap to reduce the refractive error, bring the refraction of the eye to the level correctable by phakic intraocular lens, and restore corneal volume. Six weeks postoperatively, the donor lenticule was spread smoothly in the interface with a minor temporal decentration in relation to pupil center. The refraction showed a reduction of astigmatism but a stronger myopization compared to preoperative calculations (right eye: -6.50 -4.00 @ 70°). At 3 months, the CDVA returned to the preoperative value of 20/32. One year postoperatively, corneal tomography showed no signs of ectasia and biomicroscopy revealed no signs of rejection. After implanting a toric myopic implantable collamer lens, the patient regained uncorrected distance visual acuity of 20/40 and full stereopsis. The refractive lenticule transplantation technique offers a solution for rare cases of post-LASIK hyperopia and high astigmatism while restoring the volume of thin corneas. Moreover, it is a reversible procedure with low probability of rejection. [J Refract Surg. 2016;32(11):780-786.]. Copyright 2016, SLACK Incorporated.

  19. Comparison of postoperative refractive outcomes: IOLMaster® versus immersion ultrasound.

    PubMed

    Whang, Woong-Joo; Jung, Byung-Ju; Oh, Tae-Hoon; Byun, Yong-Soo; Joo, Choun-Ki

    2012-01-01

    To compare the postoperative refractive outcomes between IOLMaster biometry (Carl Zeiss Meditec, Inc., Dublin, CA) and immersion ultrasound biometry for axial length measurements. Refractive outcomes in 354 eyes were compared using the IOLMaster and the immersion ultrasound biometry. Predicted refraction was determined using manual keratometry and the SRK-T formula with personalized A-constant. The axial lengths measured using the IOLMaster and immersion ultrasound were 24.49 ± 2.11 and 24.46 ± 2.11 mm, respectively, and the difference was significant (P < .05). The mean errors were 0.000 ± 0.578 D with the IOLMaster, and 0.000 ± 0.599 D with the immersion ultrasound, but the difference was not significant. The mean absolute error was smaller with the IOLMaster than with immersion ultrasound (0.463 ± 0.341 vs 0.479 ± 0.359 D), but the difference was not significant. IOLMaster biometry yields highly accurate results in cataract surgery. However, if the IOLMaster is unavailable, immersion ultrasound biometry with personalized intraocular lens constants is an acceptable alternative. Copyright 2012, SLACK Incorporated.

  20. New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism.

    PubMed

    Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia

    2018-02-01

    To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation.

    PubMed

    McNeely, Richard N; Moutari, Salissou; Pazo, Eric; Moore, Jonathan E

    2018-01-01

    To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

  2. Intelligent Planning for Laser Refractive Surgeries

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yue, Yong; Elsheikh, Ahmed; Bao, Fangjun

    2018-02-01

    Refractive error is one of leading ophthalmic diseases for both genders all over the world. Laser refractive correction surgery, e.g., laser in-situ keratomileusis (LASIK), has been commonly used worldwide. The prediction of surgical parameters, e.g., corneal ablation depth, depends on the doctor’s experience, theoretical formula and surgery reference manual in the preoperative diagnosis. The error of prediction may present a potential surgical risk and complication. Being aware of the surgery parameters is important because these can be used to estimate a patient’s post-operative visual quality and help the surgeon plan a suitable treatment. Therefore, in this paper we discuss data mining techniques that can be utilized for the prediction of laser refractive correction surgery parameters. It can provide the surgeon with a reference for possible surgical parameters and outcomes of the patient before the laser refractive correction surgery.

  3. Prevalence of cataract surgery and visual outcomes in Indian immigrants in Singapore: the Singapore Indian eye study.

    PubMed

    Gupta, Preeti; Zheng, Yingfeng; Ting, Tay Wan; Lamoureux, Ecosse L; Cheng, Ching-Yu; Wong, Tien-Yin

    2013-01-01

    To determine the prevalence of cataract surgery and factors associated with post-surgical visual outcomes in migrant Indians living in Singapore. We conducted a population-based study in 3,400 Indian immigrants residing in Singapore-the Singapore Indian Eye Study (SINDI). All participants underwent comprehensive medical eye examination and a standardized interview. Post-operative visual impairment (VI) was defined as best-corrected or presenting visual acuity (BCVA or PVA) of 20/60 or worse. The age- and gender-standardized prevalence of cataract surgery was 9.7% (95% confidence interval [CI]: 8.9%, 10.7%) in Singapore resident Indians. Post-operative VI defined by BCVA occurred in 10.9% eyes (87/795). The main causes of post-operative VI were diabetic retinopathy (20.7%), posterior capsular opacification (18.4%), and age-related macular degeneration (12.6%). Undercorrected refractive error doubled the prevalence of post-operative VI when PVA was used. The rate of cataract surgery is about 10% in Indian residents in Singapore. Socioeconomic variables and migration had no significant impact on the prevalence of cataract surgery. Diabetic retinopathy was a major cause of post-operative VI in migrant Indians living in Singapore. Uncorrected postoperative refractive error remains an efficient way to improve vision.

  4. Clear lens phacoemulsification in Alport syndrome: refractive results and electron microscopic analysis of the anterior lens capsule.

    PubMed

    Bayar, Sezin Akca; Pinarci, Eylem Yaman; Karabay, Gulten; Akman, Ahmet; Oto, Sibel; Yilmaz, Gursel

    2014-01-01

    To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group. Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy. All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome. Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.

  5. The effect of procedure room temperature and humidity on LASIK outcomes.

    PubMed

    Seider, Michael I; McLeod, Stephen D; Porco, Travis C; Schallhorn, Steven C

    2013-11-01

    To determine whether procedure room temperature or humidity during LASIK affect refractive outcomes in a large patient sample. Retrospective cohort study. A total of 202 394 eyes of 105 712 patients aged 18 to 75 years who underwent LASIK at an Optical Express, Inc., location in their United Kingdom and Ireland centers from January 1, 2008, to June 30, 2011, who met inclusion criteria. Patient age, gender, flap creation technique, pre- and 1-month post-LASIK manifest refraction, and ambient temperature and humidity during LASIK were recorded. Effect size determination and univariate and multivariate analyses were performed to characterize the relationships between LASIK procedure room temperature and humidity and postoperative refractive outcome. One month post-LASIK manifest refraction. No clinically significant effect of procedure room temperature or humidity was found on LASIK refractive outcomes. When considering all eyes in our population, an increase of 1°C during LASIK was associated with a 0.003 diopter (D) more hyperopic refraction 1 month postoperatively, and an increase in 1% humidity was associated with a 0.0004 more myopic refraction. These effect sizes were the same or similar when considering only myopic eyes, only hyperopic eyes, and subgroups of eyes stratified by age and preoperative refractive error. Neither procedure room temperature nor humidity during LASIK were found to have a clinically significant relationship with postoperative manifest refraction in our population. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. The effect of procedure room temperature and humidity on LASIK outcomes

    PubMed Central

    Seider, Michael I.; McLeod, Stephen D.; Porco, Travis C.; Schallhorn, Steven C.

    2013-01-01

    Objective To determine if procedure room temperature and humidity during LASIK affects refractive outcomes in a very large patient sample. Design Retrospective cohort study. Participants 202,394 eyes of 105,712 patients aged 18 to 75 years old who underwent LASIK at an Optical Express, Inc. location in their United Kingdom and Ireland centers from January 1, 2008 to June 30, 2011 who met inclusion criteria. Methods Patient age, gender, pre- and one month post-LASIK manifest refraction and flap creation technique were recorded as well as the ambient temperature and humidity during LASIK. Effect size determination, in addition to univariate and multivariate analysis was performed to characterize the relationships between LASIK procedure room temperature and humidity and post-operative refractive outcome. Main Outcome Measures One month post-LASIK manifest refraction. Results No clinically significant effect of procedure room temperature or humidity was found on LASIK refractive outcomes. When considering all eyes in our population, an increase of one degree Celsius during LASIK was associated with a 0.003 diopter more hyperopic refraction one month post-operatively and an increase in one percent humidity was associated with a 0.0004 more myopic refraction. These effect sizes were the same or similar when considering only myopic eyes, only hyperopic eyes and subgroups of eyes stratified by age and pre-operative refractive error. Conclusions Procedure room temperature or humidity during LASIK was found to have no clinically significant relationship with post-operative manifest refraction in our population. PMID:23769199

  7. Post implantation adjustable intraocular lenses.

    PubMed

    Schwartz, D M; Jethmalani, J M; Sandstedt, C A; Kornfield, J A; Grubbs, R H

    2001-06-01

    To eliminate persistent refractive errors after cataract and phakic IOL surgery, photosensitive silicone IOLs have been developed. These IOL formulations enable precise laser adjustment of IOL power to correct spherical and toric errors post-operatively, after wound and IOL stabilization. Initial experience with these laser adjustable IOLs indicate excellent biocompatability and adjustability of more than five diopters.

  8. Scleral fixation of foldable acrylic intraocular lenses in aphakic post-vitrectomy eyes

    PubMed Central

    Mutoh, Tetsuya; Matsumoto, Yukihiro; Chikuda, Makoto

    2011-01-01

    Purpose To evaluate the outcome for scleral fixation of a foldable acrylic intraocular lens (IOL) in aphakic post-pars plana vitrectomy eyes for vitreoretinal disease. Methods The medical records of 15 patients were reviewed. We evaluated such factors as the underlying vitreoretinal disease, preoperative expected refraction and postoperative actual refraction, best corrected visual acuity (BCVA), corneal endothelial cell density, and intraoperative and postoperative complications. Results The most common cause of underlying vitreoretinal disease was retinal detachment, which was found in 8 cases. The mean refractive error was −0.10 diopters (D). The mean minimum angle of resolution (logMAR) values of BCVA were 0.27 preoperatively and 0.14 postoperatively. The mean corneal endothelial cell density was 2400 cells/mm2 preoperatively and 2187 cells/mm2 postoperatively. No significant differences were observed in either the logMAR values of BCVA or the corneal endothelial cell density before and after surgery. No intraoperative complications occurred in any of the patients. Postoperative complications occurred in a total of 7 eyes, and the most severe complications comprised 4 cases of transient ocular hypertension. Conclusion The results for the scleral fixation of foldable acrylic IOLs were good in aphakic post-vitrectomy eyes. PMID:21311652

  9. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    PubMed

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P <0.01). The residual percentages in both groups were measured with refractive astigmatism of more than -0.5 diopters. Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  10. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    PubMed Central

    Kanellopoulos, Anastasios John

    2016-01-01

    Purpose To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Setting Private clinical ophthalmology practice. Patients and methods A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Results Mean refractive error was −5.5 D of myopia and −1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over −0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B (P<0.01). The residual percentages in both groups were measured with refractive astigmatism of more than −0.5 diopters. Conclusion Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction. PMID:27843292

  11. Influence of the difference between corneal and refractive astigmatism on LASIK outcomes using solid-state technology.

    PubMed

    Piñero, David P; Ribera, David; Pérez-Cambrodí, Rafael J; Ruiz-Fortes, Pedro; Blanes-Mompó, Francisco J; Alzamora-Rodríguez, Antonio; Artola, Alberto

    2014-12-01

    To evaluate the influence of the difference between preoperative corneal and refractive astigmatism [ocular residual astigmatism (ORA)] on outcomes obtained after laser in situ keratomileusis (LASIK) surgery for correction of myopic astigmatism using the solid-state laser technology. One hundred one consecutive eyes with myopia or myopic astigmatism of 55 patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd, currently CV Laser) were included. Visual and refractive changes at 6 months postoperatively and changes in ORA and anterior corneal astigmatism and posterior corneal astigmatism (PCA) were analyzed. Postoperatively, uncorrected distance visual acuity improved significantly (P < 0.01). Likewise, refractive cylinder magnitude and spherical equivalent were reduced significantly (P < 0.01). In contrast, no significant changes were observed in ORA magnitude (P = 0.81) and anterior corneal astigmatism (P = 0.12). The mean overall efficacy and safety indices were 0.96 and 1.01, respectively. These indices were not correlated with preoperative ORA (r = -0.15, P = 0.15). Furthermore, a significant correlation was found between ORA (r = 0.81, P < 0.01) and PCA postoperatively, but not preoperatively (r = 0.12, P = 0.25). Likewise, a significant correlation of ORA with manifest refraction was only found postoperatively (r = -0.38, P < 0.01). The magnitude of ORA does not seem to be a predictive factor of efficacy and safety of myopic LASIK using a solid-state laser platform. The higher relevance of PCA after surgery in some cases may explain the presence of unexpected astigmatic residual refractive errors.

  12. Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

    PubMed

    Özcura, Fatih; Aktaş, Serdar; Sağdık, Hacı Murat; Tetikoğlu, Mehmet

    2016-10-01

    The purpose of the study was to compare the accuracy of various biometric formulas for predicting postoperative refraction determined using applanation A-scan ultrasound. This retrospective comparative study included 485 eyes that underwent uneventful phacoemulsification with intraocular lens (IOL) implantation. Applanation A-scan ultrasound biometry and postoperative manifest refraction were obtained in all eyes. Biometric data were entered into each of the five IOL power calculation formulas: SRK-II, SRK/T, Holladay I, Hoffer Q, and Binkhorst II. All eyes were divided into three groups according to axial length: short (≤22.0 mm), average (22.0-25.0 mm), and long (≥25.0 mm) eyes. The postoperative spherical equivalent was calculated and compared with the predicted refractive error using each biometric formula. The results showed that all formulas had significantly lower mean absolute error (MAE) in comparison with Binkhorst II formula (P < 0.01). The lowest MAE was obtained with the SRK-II for average (0.49 ± 0.40 D) and short (0.67 ± 0.54 D) eyes and the SRK/T for long (0.61 ± 0.50 D) eyes. The highest postoperative hyperopic shift was seen with the SRK-II for average (46.8 %), short (28.1 %), and long (48.4 %) eyes. The highest postoperative myopic shift was seen with the Holladay I for average (66.4 %) and long (71.0 %) eyes and the SRK/T for short eyes (80.6 %). In conclusion, the SRK-II formula produced the lowest MAE in average and short eyes and the SRK/T formula produced the lowest MAE in long eyes. The SRK-II has the highest postoperative hyperopic shift in all eyes. The highest postoperative myopic shift is with the Holladay I for average and long eyes and SRK/T for short eyes.

  13. Agreement Between Autorefraction and Subjective Refraction in Keraring-Implanted Keratoconic Eyes.

    PubMed

    Al-Tuwairqi, Waleed S; Ogbuehi, Kelechi C; Razzouk, Haya; Alanazi, Mana A; Osuagwu, Uchechukwu L

    2017-03-01

    To assess the agreement between subjective refraction and autorefraction and to explore the relationship between the magnitude of higher order aberration, and visual acuity and refraction, before and after keraring implantation. This prospective, randomized, interventional study enrolled 27 subjects (mean age 28.1±6.5 years) with keratoconus. Noncycloplegic refraction was performed subjectively by one clinician and with an autorefractor by another clinician, before and 6 months after surgery. The limit of agreement (LoA) between methods was assessed, and the relationships between the corrected distance visual acuity, logMAR on the one hand and refraction measurements and higher-order aberrations on the other, were examined. The agreement in mean spherical equivalent refraction (MSER) between methods was good postoperatively but poor preoperatively. The autorefractor gave a more myopic refraction than subjective refraction preoperatively (-3.28±3.06 D; LoA -9.27 to +2.71 D, P<0.0001) and postoperatively (-0.63±1.64 D; LoA -3.85 to +2.58 D, P=0.055), and returned higher negative cylinders preoperatively (-1.10±1.17 D; LoA -3.40 to +1.19 D, P<0.0001) and postoperatively (-1.08±1.27 D; LoA -3.60 to +1.41 D, P<0.0001) in keratoconic eyes. The difference in MSER between methods was significantly related to the refractive error at both visits (P<0.05) and to the magnitude of higher-order aberrations in keratoconic eyes preoperatively (P<0.05). The logMAR visual acuity achieved subjectively worsened as the magnitude of higher-order aberrations increased preoperatively (P<0.001). The autorefractor returns values that are significantly more myopic in MSER and higher negative cylinders than subjective refraction, preoperatively, but the MSER was similar between devices postoperatively. The autorefactor seems a valid starting point for subjective refraction in keratoconic eyes treated with keraring, but the cylinder should be corrected by about +1 D. The instruments agree more in less myopic than high myopic eyes.

  14. Laser in-situ keratomileusis for refractive error following radial keratotomy

    PubMed Central

    Sinha, Rajesh; Sharma, Namrata; Ahuja, Rakesh; Kumar, Chandrashekhar; Vajpayee, Rasik B

    2011-01-01

    Aim: To evaluate the safety and efficacy of laser in-situ keratomileusis (LASIK) in eyes with residual/induced refractive error following radial keratotomy (RK). Design: Retrospective study. Materials and Methods: A retrospective analysis of data of 18 eyes of 10 patients, who had undergone LASIK for refractive error following RK, was performed. All the patients had undergone RK in both eyes at least one year before LASIK. Parameters like uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), contrast sensitivity, glare acuity and corneal parameters were evaluated both preoperatively and postoperatively. Statistical Software: STATA-9.0. Results: The mean UCVA before LASIK was 0.16±0.16 which improved to 0.64 ± 0.22 (P < 0.001) after one year following LASIK. Fourteen eyes (out of 18) had UCVA of ≥ 20/30 on Snellen's acuity chart at one year following LASIK. The mean BCVA before LASIK was 0.75 ± 0.18. This improved to 0.87 ± 0.16 at one year following LASIK. The mean spherical refractive error at the time of LASIK and at one year after the procedure was –5.37 ± 4.83 diopters (D) and –0.22 ± 1.45D, respectively. Only three eyes had a residual spherical refractive error of ≥ 1.0D at one year follow-up. In two eyes, we noted opening up of the RK incisions. No eye developed epithelial in-growth till 1 year after LASIK. Conclusion: LASIK is effective in treating refractive error following RK. However, it carries the risk of flap-related complications like opening up of the previously placed RK incisions and splitting of the corneal flap. PMID:21666312

  15. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    PubMed

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  16. Outcome of cataract surgery at one year in Kenya, the Philippines and Bangladesh.

    PubMed

    Lindfield, R; Kuper, H; Polack, S; Eusebio, C; Mathenge, W; Wadud, Z; Rashid, A M; Foster, A

    2009-07-01

    To assess the change in vision following cataract surgery in Kenya, Bangladesh and the Philippines and to identify causes and predictors of poor outcome. Cases were identified through surveys, outreach and clinics. They underwent preoperative visual acuity measurement and ophthalmic examination. Cases were re-examined 8-15 months after cataract surgery. Information on age, gender, poverty and literacy was collected at baseline. 452 eyes of 346 people underwent surgery. 124 (27%) eyes had an adverse outcome. In Kenya and the Philippines, the main cause of adverse outcome was refractive error (37% and 49% respectively of all adverse outcomes) then comorbid ocular disease (26% and 27%). In Bangladesh, this was comorbid disease (58%) then surgical complications (21%). There was no significant association between adverse outcome and gender, age, literacy, poverty or preoperative visual acuity. Adverse outcomes following cataract surgery were frequent in the three countries. Main causes were refractive error and preoperative comorbidities. Many patients are not attaining the outcomes available with modern surgery. Focus should be on correcting refractive error, through operative techniques or postoperative refraction, and on a system for assessing comorbidities and communicating risk to patients. These are only achievable with a commitment to ongoing surgical audit.

  17. High resolution OCT quantitative analysis of the space between the IOL and the posterior capsule during the early cataract postoperative period.

    PubMed

    Tao, Aizhu; Lu, Ping; Li, Jin; Shao, Yilei; Wang, Jianhua; Shen, Meixiao; Zhao, Yinying; Lu, Fan

    2013-10-25

    We quantitatively characterized the space between the IOL and the posterior capsule (IOL-PC space) during the early postphacoemulsification period, using high resolution optical coherence tomography (OCT). We recruited 30 eyes of 30 patients who underwent phacoemulsification and randomly divided them into two groups. Acrysof Natural IQ IOLs were implanted in one group (n = 15), and Adapt-AO IOLs were implanted into the other (n = 15). A custom-built OCT instrument was used to image the IOL-PC space at 1 day, 1 week, and 1 month after surgery. Slit-lamp examination and auto refraction were performed at each visit. The IOL-PC spaces in the IQ group were 0.72 ± 0.35, 0.40 ± 0.24, and 0.23 ± 0.16 mm(2) at 1 day, 1 week, and 1 month after surgery, respectively. At each of these times, the values for the AO group were significantly smaller (P < 0.001). Compared to 1 day after surgery, significant changes in the ACDs and refractive errors occurred up to 1 month postoperatively in the IQ group; however, changes in the ACD and refractive error were significant only at 1 week in the AO group. The decreases in IOL-PC space and in ACD during the early postoperative period were associated with a myopic shift. It appeared that the different IOL designs had a role in closure of the IOL-PC space. High resolution OCT was suitable for quantitative analysis of IOL-PC space. (ClinicalTrials.gov number, NCT01605812.).

  18. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  19. Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

    PubMed

    Nemeth, Gabor; Nagy, Attila; Berta, Andras; Modis, Laszlo

    2012-09-01

    Comparison of postoperative refraction results using ultrasound biometry with closed immersion shell and optical biometry. Three hundred and sixty-four eyes of 306 patients (age: 70.6 ± 12.8 years) underwent cataract surgery where intraocular lenses calculated by SRK/T formula were implanted. In 159 cases immersion ultrasonic biometry, in 205 eyes optical biometry was used. Differences between predicted and actual postoperative refractions were calculated both prior to and after optimization with the SRK/T formula, after which we analysed the similar data in the case of Holladay, Haigis, and Hoffer-Q formulas. Mean absolute error (MAE) and the percentage rate of patients within ±0.5 and ±1.0 D difference in the predicted error were calculated with these four formulas. MAE was 0.5-0.7 D in cases of both methods with SRK/T, Holladay, and Hoffer-Q formula, but higher with Haigis formula. With no optimization, 60-65 % of the patients were under 0.5 D error in the immersion group (except for Haigis formula). Using the optical method, this value was slightly higher (62-67 %), however, in this case, Haigis formula also did not perform so well (45 %). Refraction results significantly improved with Holladay, Hoffer-Q, and Haigis formulas in both groups. The rate of patients under 0.5 D error increased to 65 % by the immersion technique, and up to 80 % by the optical one. According to our results, optical biometry offers only slightly better outcomes compared to those of immersion shell with no optimized formulas. However, in case of new generation formulas with both methods, the optimization of IOL-constants give significantly better results.

  20. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses.

    PubMed

    Savini, Giacomo; Næser, Kristian

    2015-01-13

    To investigate the influence of posterior corneal astigmatism, surgically-induced corneal astigmatism (SICA), intraocular lens (IOL) orientation, and effective lens position on the refractive outcome of toric IOLs. Five models were prospectively investigated. Keratometric astigmatism and an intended SICA of 0.2 diopters (D) were entered into model 1. Total corneal astigmatism, measured by a rotating Scheimpflug camera, was used instead of keratometric astigmatism in model 2. The mean postoperative SICA, the actual postoperative IOL orientation, and the influence of the effective lens position were added, respectively, into models 3, 4, and 5. Astigmatic data were vectorially described by meridional and torsional powers. A set of equations was developed to describe the error in refractive astigmatism (ERA) as the difference between the postoperative refractive astigmatism and the target refractive astigmatism. We enrolled 40 consecutive eyes. In model 1, ERA calculations revealed significant cylinder overcorrection in with-the-rule (WTR) eyes (meridional power = -0.59 ± 0.34 D, P < 0.0001) and undercorrection in against-the-rule (ATR) eyes (0.32 ± 0.42 D, P = 0.01). When total corneal astigmatism was used instead of keratometric astigmatism (model 2), the ERA meridional power decreased in WTR (-0.13 ± 0.42 D) and ATR (0.07 ± 0.59 D) eyes, both values being not statistically significant. Models 3 to 5 did not lead to significant improvement. Posterior corneal astigmatism exerts the highest influence on the ERA after toric IOL implantation. Basing calculations on total corneal astigmatism rather than keratometric astigmatism improves the prediction of the residual refractive astigmatism. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  1. Astigmatism Correction With Toric Intraocular Lenses in Descemet Membrane Endothelial Keratoplasty Triple Procedures.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2017-03-01

    To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.

  2. A web-based information system for management and analysis of patient data after refractive eye surgery.

    PubMed

    Zuberbuhler, Bruno; Galloway, Peter; Reddy, Aravind; Saldana, Manuel; Gale, Richard

    2007-12-01

    The aim was to develop a software tool for refractive surgeons using a standard user-friendly web-based interface, providing the user with a secure environment to protect large volumes of patient data. The software application was named "Internet-based refractive analysis" (IBRA), and was programmed with the computer languages PHP, HTML and JavaScript, attached to the opensource MySQL database. IBRA facilitated internationally accepted presentation methods including the stability chart, the predictability chart and the safety chart; it was able to perform vector analysis for the course of a single patient or for group data. With the integrated nomogram calculation, treatment could be customised to reduce the postoperative refractive error. Multicenter functions permitted quality-control comparisons between different surgeons and laser units.

  3. A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length.

    PubMed

    Doshi, Dharmil; Limdi, Purvi; Parekh, Nilesh; Gohil, Neepa

    2017-01-01

    Accurate Intraocular Lens (IOL) power calculation in cataract surgery is very important for providing postoperative precise vision. Selection of most appropriate formula is difficult in high myopic and hypermetropic patients. To investigate the predictability of different IOL (Intra Ocular Lens) power calculation formulae in eyes with short and long Axial Length (AL) and to find out most accurate IOL power calculation formula in both groups. A prospective study was conducted on 80 consecutive patients who underwent phacoemulsification with monofocal IOL implantation after obtaining an informed and written consent. Preoperative keratometry was done by IOL Master. Axial length and anterior chamber depth was measured using A-scan machine ECHORULE 2 (BIOMEDIX). Patients were divided into two groups based on AL. (40 in each group). Group A with AL<22 mm and Group B with AL>24.5 mm. The IOL power calculation in each group was done by Haigis, Hoffer Q, Holladay-I, SRK/T formulae using the software of ECHORULE 2. The actual postoperative Spherical Equivalent (SE), Estimation error (E) and Absolute Error (AE) were calculated at one and half months and were used in data analysis. The predictive accuracy of each formula in each group was analyzed by comparing the Absolute Error (AE). The Kruskal Wallis test was used to compare differences in the (AE) of the formulae. A statistically significant difference was defined as p-value<0.05. In Group A, Hoffer Q, Holladay 1 and SRK/T formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm and accuracy of these three formulae was significantly higher than Haigis formula. Whereas in Group B, Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL more than 24.5 mm. Hoffer Q, Holladay 1 and SRK/T formulae were showing significantly higher accuracy than Haigis formula in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm. In eyes with AL more than 24.5 mm Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate.

  4. A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length

    PubMed Central

    Limdi, Purvi; Parekh, Nilesh; Gohil, Neepa

    2017-01-01

    Introduction Accurate Intraocular Lens (IOL) power calculation in cataract surgery is very important for providing postoperative precise vision. Selection of most appropriate formula is difficult in high myopic and hypermetropic patients. Aim To investigate the predictability of different IOL (Intra Ocular Lens) power calculation formulae in eyes with short and long Axial Length (AL) and to find out most accurate IOL power calculation formula in both groups. Materials and Methods A prospective study was conducted on 80 consecutive patients who underwent phacoemulsification with monofocal IOL implantation after obtaining an informed and written consent. Preoperative keratometry was done by IOL Master. Axial length and anterior chamber depth was measured using A-scan machine ECHORULE 2 (BIOMEDIX). Patients were divided into two groups based on AL. (40 in each group). Group A with AL<22 mm and Group B with AL>24.5 mm. The IOL power calculation in each group was done by Haigis, Hoffer Q, Holladay-I, SRK/T formulae using the software of ECHORULE 2. The actual postoperative Spherical Equivalent (SE), Estimation error (E) and Absolute Error (AE) were calculated at one and half months and were used in data analysis. The predictive accuracy of each formula in each group was analyzed by comparing the Absolute Error (AE). The Kruskal Wallis test was used to compare differences in the (AE) of the formulae. A statistically significant difference was defined as p-value<0.05. Results In Group A, Hoffer Q, Holladay 1 and SRK/T formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm and accuracy of these three formulae was significantly higher than Haigis formula. Whereas in Group B, Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL more than 24.5 mm. Conclusion Hoffer Q, Holladay 1 and SRK/T formulae were showing significantly higher accuracy than Haigis formula in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm. In eyes with AL more than 24.5 mm Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate. PMID:28273986

  5. Implantation of a customized toric intraocular lens for correction of post-keratoplasty astigmatism

    PubMed Central

    Srinivasan, S; Ting, D S J; Lyall, D A M

    2013-01-01

    Purpose To report visual and refractive outcomes, and endothelial cell loss following primary and secondary ‘piggyback' toric intraocular lens (IOL) implantation in patients with high post-penetrating keratoplasty (PK) astigmatism. Methods Prospective case series. Nine eyes of nine patients with post-PK astigmatism were consecutively recruited for implantation of a customized toric IOL. Six underwent simultaneous phacoemulsification (PE) and three pseudophakic eyes had a secondary ‘piggyback' toric IOL implanted in the ciliary sulcus. Mean follow-up time was 17.2±7.7 months. Pre- and post-operative uncorrected (UDVA) and best-corrected (BDVA) distance visual acuities and refractive errors were collected for comparison. Cartesian astigmatic vectors were calculated to identify a change in the magnitude of astigmatism pre- compared to postoperatively. Pre- and post-operative endothelial cell counts were also collected for analysis. Results UDVA (logMAR) improved from 1.13±0.51 preoperatively to 0.48±0.24 postoperatively (P-value=0.003). There was no significant change in BDVA (P-value=0.905) from 0.31±0.27 to 0.26±0.19. Corneal astigmatism preoperatively was 6.57±4.40 diopters (D). Post-operative refractive cylinder was 0.83±1.09 D compared to 3.89±4.01 D preoperatively (P=0.039). Analysis of astigmatic Cartesian x and y coordinates found a significant reduction postoperatively compared to preoperatively (P=0.005 and P=0.002), respectively. Mean endothelial cell loss was 9.9%. Conclusion: Implantation of a customized primary or secondary ‘piggyback' toric IOL serves as an effective modality in treating patients with high post-PK astigmatism. PMID:23348728

  6. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  7. Optical Coherence Tomography–Based Corneal Power Measurement and Intraocular Lens Power Calculation Following Laser Vision Correction (An American Ophthalmological Society Thesis)

    PubMed Central

    Huang, David; Tang, Maolong; Wang, Li; Zhang, Xinbo; Armour, Rebecca L.; Gattey, Devin M.; Lombardi, Lorinna H.; Koch, Douglas D.

    2013-01-01

    Purpose: To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. Methods: Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anterior chamber depth, and automated keratometry were measured by a partial coherence interferometer. An OCT-based IOL formula was developed. The mean absolute error of the OCT-based formula in predicting postoperative refraction was compared to two regression-based IOL formulae for eyes with previous laser vision correction. Results: Forty-six eyes of 46 patients all had uncomplicated cataract surgery with monofocal IOL implantation. The mean arithmetic prediction error of postoperative refraction was 0.05 ± 0.65 diopter (D) for the OCT formula, 0.14 ± 0.83 D for the Haigis-L formula, and 0.24 ± 0.82 D for the no-history Shammas-PL formula. The mean absolute error was 0.50 D for OCT compared to a mean absolute error of 0.67 D for Haigis-L and 0.67 D for Shammas-PL. The adjusted mean absolute error (average prediction error removed) was 0.49 D for OCT, 0.65 D for Haigis-L (P=.031), and 0.62 D for Shammas-PL (P=.044). For OCT, 61% of the eyes were within 0.5 D of prediction error, whereas 46% were within 0.5 D for both Haigis-L and Shammas-PL (P=.034). Conclusions: The predictive accuracy of OCT-based IOL power calculation was better than Haigis-L and Shammas-PL formulas in eyes after laser vision correction. PMID:24167323

  8. Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results.

    PubMed

    Woodcock, Michael G; Lehmann, Robert; Cionni, Robert J; Breen, Michael; Scott, Maria C

    2016-06-01

    To compare astigmatic outcomes in patients with bilateral cataracts having toric intraocular lens (IOL) implantation with intraoperative aberrometry measurements in 1 eye and standard power calculation and a toric IOL calculator with inked axis marking in the contralateral eye. Twelve sites in the United States. Prospective cohort study. The eye with the more visually significant cataract was randomized to intraoperative aberrometry measurements (Ocular Response Analyzer with Verifeye) or standard preoperative biometry and use of a toric calculator with the contralateral eye automatically assigned to the other group. The primary effectiveness outcome was the proportion of eyes with a postoperative refractive astigmatism of 0.50 diopter (D) or less at 1 month. Of the 130 patients (260 eyes) enrolled, 124 (248 eyes) were randomized; 121 (242 eyes) completed the trial. The percentage of eyes with astigmatism of 0.50 D or less at 1 month was higher in the intraoperative aberrometry group than in the standard group (89.2% versus 76.6%) (P = .006). The mean postoperative refractive astigmatism was lower in the intraoperative aberrometry group (0.29 D ± 0.28 [SD] versus 0.36 ± 0.35 D) (P = .041). Secondary effectiveness endpoints, including manifest refraction spherical equivalent prediction error, uncorrected distance visual acuity, and corrected distance visual acuity, were similar. Compared with standard methods, the use of the intraoperative aberrometry system increased the proportion of eyes with postoperative refractive astigmatism of 0.50 D or less and reduced the mean postoperative refractive astigmatism at 1 month. Other efficacy outcomes were similar. Drs. Woodcock, Lehmann, and Cionni are consultants to Alcon Laboratories, Inc. Dr. Breen is an employee of Alcon Laboratories, Inc. Dr. Scott has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    NASA Astrophysics Data System (ADS)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  10. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK).

    PubMed

    Koenig, Steven B; Covert, Douglas J; Dupps, William J; Meisler, David M

    2007-07-01

    To evaluate visual acuity, refractive outcomes, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). We performed an institutional review board-approved prospective study of a surgical case series of 34 patients at 2 institutions undergoing DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, or aphakic bullous keratopathy with or without simultaneous phacoemulsification and intraocular lens implantation. Clinical outcomes, including best spectacle-corrected visual acuity (BSCVA), spherical equivalent refraction, and refractive astigmatism and topographic or keratometric astigmatism, were assessed at the 6-month postoperative examination and compared with preoperative values with paired Student t tests. The change in endothelial cell density from the eye bank examination to 6 months after transplantation was similarly evaluated. BSCVA averaged 20/99 preoperatively and 20/42 postoperatively (P < 0.0001). After DSAEK, 30 (88.2%) of 34 patients showed improved BSCVA, and 21 (61.8%) of the 34 patients achieved a BSCVA of 20/40 or better. For patients not undergoing simultaneous phacoemulsification and intraocular lens implantation, a hyperopic shift in refraction of 1.19 +/- 1.32 D was noted. Refractive astigmatism, topographic astigmatism, and keratometry showed no statistically significant change. Endothelial cell density of donor corneas averaged 2826 +/- 370 cells/mm, whereas the mean postoperative density was 1396 +/- 440 cells/mm. This finding corresponded to an average loss of 1426 cells/mm (50% loss; P = 0.0001). The first half of cases experienced an average cell loss of 1674 cells/mm (59% loss) compared with 1181 (41% loss) in the second half of cases (P = 0.005). Three (9%) of 34 grafts experienced iatrogenic graft failure and required reoperation with new donor tissue. Also, 9 (27%) of 34 grafts experienced dislocation in the early postoperative period and required repositioning. In this prospective study of DSAEK for bullous keratopathy and Fuchs endothelial corneal dystrophy, improvement of visual acuity was achieved with only a mild tendency toward hyperopic shift and without significant induced astigmatism. Endothelial cell loss was significant, however, and may be related to surgical experience.

  11. Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

    PubMed

    Kolega, Marija Škara; Kovačević, Suzana; Čanović, Samir; Pavičić, Ana Didović; Bašić, Jadranka Katušić

    2015-03-01

    Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

  12. Effect of trabeculectomy on the accuracy of intraocular lens calculations in patients with open-angle glaucoma.

    PubMed

    Bae, Hyoung Won; Lee, Yun Ha; Kim, Do Wook; Lee, Taekjune; Hong, Samin; Seong, Gong Je; Kim, Chan Yun

    2016-08-01

    The objective of the study is to examine the effect of trabeculectomy on intraocular lens power calculations in patients with open-angle glaucoma (OAG) undergoing cataract surgery. The design is retrospective data analysis. There are a total of 55 eyes of 55 patients with OAG who had a cataract surgery alone or in combination with trabeculectomy. We classified OAG subjects into the following groups based on surgical history: only cataract surgery (OC group), cataract surgery after prior trabeculectomy (CAT group), and cataract surgery performed in combination with trabeculectomy (CCT group). Differences between actual and predicted postoperative refractive error. Mean error (ME, difference between postoperative and predicted SE) in the CCT group was significantly lower (towards myopia) than that of the OC group (P = 0.008). Additionally, mean absolute error (MAE, absolute value of ME) in the CAT group was significantly greater than in the OC group (P = 0.006). Using linear mixed models, the ME calculated with the SRK II formula was more accurate than the ME predicted by the SRK T formula in the CAT (P = 0.032) and CCT (P = 0.035) groups. The intraocular lens power prediction accuracy was lower in the CAT and CCT groups than in the OC group. The prediction error was greater in the CAT group than in the OC group, and the direction of the prediction error tended to be towards myopia in the CCT group. The SRK II formula may be more accurate in predicting residual refractive error in the CAT and CCT groups. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  13. Changes in Astigmatism, Densitometry, and Aberrations After SMILE for Low to High Myopic Astigmatism: A 12-Month Prospective Study.

    PubMed

    Pedersen, Iben Bach; Ivarsen, Anders; Hjortdal, Jesper

    2017-01-01

    To evaluate 12-month changes in refraction, visual outcome, corneal densitometry, and postoperative aberrations after small incision lenticule extraction (SMILE) for myopic astigmatism. This 12-month prospective clinical trial comprised 101 eyes (101 patients) treated with SMILE for myopic astigmatism with cylinder of 0.75 to 4.00 diopters (D). The preoperative, 1-week, and 1-, 3-, 6-, 9-, and 12-month examinations included measurement of manifest refraction, uncorrected distance visual acuity (UDVA), and corrected (CDVA) distance visual acuity. Astigmatic error vector analysis was performed using Al-pin's method. Densitometry and aberrations were evaluated with Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany). Preoperative spherical equivalent averaged -6.78 ± 1.90 D with 1.81 ± 1.00 D in cylinder correction. After 12 months, 74% and 93% of the eyes were within ±0.50 and ±1.00 D of the attempted refraction, respectively. The logMAR UDVA and CDVA averaged 0.03 ± 0.16 and -0.08 ± 0.09, respectively. Vector analysis showed a with-the-rule undercorrection at 12 months with a mean difference vector of 0.31 D @ 91°. There was a minor counterclockwise rotation of the axis, with an arithmetic angle of error of 0.34° ± 14°. An undercorrection of approximately 11% per diopter of attempted correction was seen at 12 months. Spherical aberrations, coma, and higher order aberrations remained stable during the postoperative period (P < .09). After 12 months, no increase in densitometry could be identified. Treatment of astigmatism with SMILE seems to be predictable and effective, but with an astigmatic undercorrection of approximately 11% and a small counterclockwise rotation of the axis. [J Refract Surg. 2017;33(1):11-17.]. Copyright 2017, SLACK Incorporated.

  14. Comparison of two techniques of marking the horizontal axis during excimer laser keratorefractive surgery for myopic astigmatism.

    PubMed

    Burka, Jenna M; Bower, Kraig S; Cute, David L; Stutzman, Richard D; Subramanian, Prem S; Rabin, Jeff C

    2005-04-01

    To compare two methods of limbal marking used during laser refractive surgery for myopic astigmatism. Retrospective chart review. Forty-two eyes of 42 patients who underwent photorefractive keratectomy (PRK) or laser-assisted in-situ keratomileusis (LASIK) for myopic astigmatism were marked preoperatively to identify the horizontal axis. In 18 eyes, marks were placed at the slit lamp (SL) with the slit beam set at 180 degrees as a reference. In 24 eyes, marks were placed in the laser room (LR) immediately before reclining under the laser. All treatments were performed with the Alcon LADARVision excimer laser system. Vector analysis of postoperative cylinder and reduction in cylinder and uncorrected and best-corrected visual acuity were evaluated for both groups. The mean postoperative magnitude of error was -0.19 +/- 0.44 diopters for the LR group and -0.09 +/- 0.42 diopters for the SL group (P = .439, NS). Both groups had a mean angle of error indicating an overall counterclockwise rotation of axis with an angle of error of 6.3 +/- 8.7 degrees for the LR group and 8.0 +/- 10.2 degrees for the SL group (P = .562, NS). We found no significant difference in outcomes with an overall trend toward undercorrection of cylinder in both groups, leaving room for improvement after refractive surgery for myopic astigmatism.

  15. Aspheric versus wavefront-guided aspheric photorefractive keratectomy in eyes with significant astigmatism.

    PubMed

    Faramarzi, Amir; Moshirfar, Majid; Karimian, Farid; Delfazayebaher, Siamak; Kheiri, Bahareh

    2017-12-01

    To compare the refractive and higher-order aberrations (HOAs) outcomes after photorefractive keratectomy (PRK) in patients with significant astigmatism using aspheric versus wavefront-guided aspheric profiles. Ophthalmic Research Center and Department of Ophthalmology, Shahid Beheshti University of Medical Sciences, Negah Eye Hospital, Tehran, Iran. Prospective randomized case series. One eye of each patient with a refractive astigmatism more than 2.00 diopters (D) randomly received aspheric PRK. In the other eye, wavefront-guided and aspheric treatment was performed using a personalized treatment advanced algorithm. Visual acuity, refractive errors, and HOAs were compared between the 2 groups preoperatively and 12 months postoperatively. The study comprised 32 patients (64 eyes). The mean preoperative refractive astigmatism was -4.07 D ± 1.64 (SD) and -4.02 ± 1.55 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .2). The mean postoperative astigmatism was -0.46 ± 0.37 D and -0.82 ± 0.53 D in the aspheric group and wavefront-guided aspheric group, respectively (P = .02). Postoperatively, the root mean square of total HOAs was significantly increased in both groups. However, compared with wavefront-guided aspheric PRK, aspheric PRK induced fewer HOAs (P = .003). In eyes with high astigmatism, post-PRK residual astigmatism was lower in the aspheric group than in the wavefront-guided aspheric group. The increase in HOAs was significantly higher in the wavefront-guided aspheric group than in the aspheric group. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Application of the holmium:YAG laser for refractive surgery: an update of clinical progress

    NASA Astrophysics Data System (ADS)

    Thompson, Vance M.; Durrie, Daniel S.; Hunkeler, John D.; Hurt, Art C., III; Mann, P. M.; Seiler, Theo; King, Michael C.; Sacharoff, Alex C.; Muller, David F.

    1993-06-01

    We describe the results of a 30 patient Phase I clinical trial using the Laser Thermokeratoplasty (LTK) treatment for correction of hyperopic astigmatism. We report the results for 29 patients who have reached 2 months post-operative. The average pre-op cylinder was reduced from -3.06 Diopters (D) to -1.21 D. Average spherical equivalent (SE) refractive error was reduced from +2.28 to +1.34 D. Six patients have reached 4 months post-op; the average cylinder of these patients has been reduced from -1.92 to -0.79 D while the average SE has been reduced from +1.29 to +0.31 D. Although patients had varying degrees of astigmatism pre-op, all treatments were performed with identical parameters (intended to correct a small amount of astigmatism) to enable us to determine the effect of the procedure without the influence of other factors such as varying zone diameter or laser fluence. The predictability and stability of the LTK procedure are supported by a recent study of 20 patients treated in Germany by Seiler for low to moderate degrees (2 - 4 D) of hyperopia. After 6 months post-op, 16 of 20 patients are within +/- 1 D of the attempted correction. Longer-term follow-up will be necessary to determine the ultimate refractive stability of the LTK procedure.

  17. Reliability study of biometrics "do not contact" in myopia.

    PubMed

    Migliorini, R; Fratipietro, M; Comberiati, A M; Pattavina, L; Arrico, L

    The aim of the study is a comparison between the actually achieved after surgery condition versus the expected refractive condition of the eye as calculated via a biometer. The study was conducted in a random group of 38 eyes of patients undergoing surgery by phacoemulsification. The mean absolute error was calculated between the predicted values from the measurements with the optical biometer and those obtained in the post-operative error which was at around 0.47% Our study shows results not far from those reported in the literature, and in relation, to the mean absolute error is among the lowest values at 0.47 ± 0.11 SEM.

  18. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    PubMed

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  19. Planning for Coupling Effects in Bitoric Mixed Astigmatism Ablative Treatments.

    PubMed

    Alpins, Noel; Ong, James K Y; Stamatelatos, George

    2017-08-01

    To demonstrate how to determine the historical coupling adjustments of bitoric mixed astigmatism ablative treatments and how to use these historical coupling adjustments to adjust future bitoric treatments. The individual coupling adjustments of the myopic and hyperopic cylindrical components of a bitoric treatment were derived empirically from a retrospective study where the theoretical combined treatment effect on spherical equivalent was compared to the actual change in refractive spherical equivalent. The coupling adjustments that provided the best fit in both mean and standard deviation were determined to be the historical coupling adjustments. Theoretical treatments that incorporated the historical coupling adjustments were then calculated. The actual distribution of postoperative spherical equivalent errors was compared to the theoretically adjusted distribution. The study group comprised 242 eyes and included 118 virgin right eyes and 124 virgin left eyes of 155 individuals. For the laser used, the myopic coupling adjustment was -0.02 and the hyperopic coupling adjustment was 0.30, as derived by global nonlinear optimization. This implies that almost no adjustment of the myopic component of the bitoric treatment is necessary, but that the hyperopic component of the bitoric treatment generates a large amount of unintended spherical shift. The theoretically adjusted treatments targeted zero mean spherical equivalent error, as intended, and the distribution of the theoretical spherical equivalent errors had the same spread as the distribution of actual postoperative spherical equivalent errors. Bitoric mixed astigmatism ablative treatments may display non-trivial coupling effects. Historical coupling adjustments should be taken into consideration when planning mixed astigmatism treatments to improve surgical outcomes. [J Refract Surg. 2017;33(8):545-551.]. Copyright 2017, SLACK Incorporated.

  20. Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for mixed astigmatism refractive surgery.

    PubMed

    Stanca, Horia Tudor; Munteanu, Mihnea; Jianu, Dragoş Cătălin; Motoc, Andrei Gheorghe Marius; Jecan, Cristian Radu; Tăbăcaru, Bogdana; Stanca, Simona; Preda, Maria Alexandra

    2018-01-01

    To evaluate the predictability, efficacy and safety of Femtosecond-laser-assisted in situ keratomileusis (LASIK) procedure for mixed astigmatism. We prospectively evaluated for 12 months 74 eyes (52 patients) with mixed astigmatism that underwent Femtosecond-LASIK treatment. The preoperative mean refractive sphere value was +1.879±1.313 diopters (D) and the mean refractive cylinder value was -4.169±1.091 D. The anterior corneal flap was cut using the VisuMax® femtosecond laser and then the stromal ablation was done using the MEL® 80 excimer laser. Mean age was 30.22±6.421 years with 61.53% female patients. Postoperative spherical equivalent at 12 months was within ±0.5D of emmetropia in 75.8% of eyes and within ±1D in 97.3% of eyes. Postoperative uncorrected distance visual acuity was equivalent to or better than the preoperative corrected distance visual acuity in 91.9% of eyes. Compared to the preoperative corrected distance visual acuity (CDVA), 8.1% of eyes gained one line, 2.7% gained two lines and 2.7% gained three lines of visual acuity. Femtosecond-LASIK using the VisuMax®-MEL® 80 platform appears to have safe, effective and predictable results in mixed astigmatic eyes. The results are impressive for high refractive error treatment and for improvement of both uncorrected and corrected distance visual acuity.

  1. Vector analysis of astigmatic correction after small-incision lenticule extraction and femtosecond-assisted LASIK for low to moderate myopic astigmatism.

    PubMed

    Chan, Tommy C Y; Ng, Alex L K; Cheng, George P M; Wang, Zheng; Ye, Cong; Woo, Victor C P; Tham, Clement C Y; Jhanji, Vishal

    2016-04-01

    To compare astigmatic correction between femtosecond-assisted laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). A total of 111 patients were included in this prospective study. Fifty-seven eyes were treated with LASIK and 54 eyes were treated with SMILE for myopia with low to moderate (-0.25 to -4.0 D) astigmatism. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity and manifest refraction were measured preoperatively and at 1 and 3 months postoperatively. Visual and refractive outcomes were reported. Changes in refractive astigmatism were evaluated using vector analysis. Preoperative characteristics were similar between both groups. The UDVA at 1 and 3 months was better in the LASIK group compared with the SMILE group (p<0.009). Postoperative cylinder was higher in the SMILE group (p<0.001). Fewer eyes attained the attempted cylindrical correction in the SMILE group (p<0.029). Vector analysis showed no significant difference in target-induced astigmatism (p=0.091) and angle of error (p>0.596) between the two groups. Surgically induced astigmatism was significantly lower in the SMILE group (p<0.023), while the difference vector (p<0.001) and absolute angle of error (p<0.016) were significantly higher in the SMILE group. No significant difference was found in these parameters between 1 and 3 months in both groups (p>0.122). Our results showed that SMILE offered a less favourable astigmatic correction comparable to femtosecond-assisted LASIK in eyes with low to moderate myopic astigmatism. The alignment of treatment was more variable in SMILE, leading to a lower efficacy compared with LASIK by 3 months postoperatively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Iris-fixated phakic intraocular lens implantation after retinal detachment surgery: long-term clinical results.

    PubMed

    Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin

    2013-10-01

    To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Management of pseudophakic myopic anisometropic amblyopia with piggyback Visian® implantable collamer lens.

    PubMed

    Eissa, Sherif A

    2017-03-01

    To assess the outcomes of sulcus implantation of the Visian ® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection. Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months. Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm. Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Non-topography-guided PRK combined with CXL for the correction of refractive errors in patients with early stage keratoconus.

    PubMed

    Fadlallah, Ali; Dirani, Ali; Chelala, Elias; Antonios, Rafic; Cherfan, George; Jarade, Elias

    2014-10-01

    To evaluate the safety and clinical outcome of combined non-topography-guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) for the treatment of mild refractive errors in patients with early stage keratoconus. A retrospective, nonrandomized study of patients with early stage keratoconus (stage 1 or 2) who underwent simultaneous non-topography-guided PRK and CXL. All patients had at least 2 years of follow-up. Data were collected preoperatively and postoperatively at the 6-month, 1-year, and 2-year follow-up visit after combined non-topography-guided PRK and CXL. Seventy-nine patients (140 eyes) were included in the study. Combined non-topography-guided PRK and CXL induced a significant improvement in both visual acuity and refraction. Uncorrected distance visual acuity significantly improved from 0.39 ± 0.22 logMAR before combined non-topography-guided PRK and CXL to 0.12 ± 0.14 logMAR at the last follow-up visit (P <.001) and corrected distance visual acuity remained stable (0.035 ± 0.062 logMAR preoperatively vs 0.036 ± 0.058 logMAR postoperatively, P =.79). The mean spherical equivalent decreased from -1.78 ± 1.43 to -0.42 ± 0.60 diopters (D) (P <.001), and the mean cylinder decreased from 1.47 ± 1.10 to 0.83 ± 0.55 D (P <.001). At the last follow-up visit mean keratometry flat was 43.30 ± 1.75 vs 45.62 ± 1.72 D preoperatively (P = .03) and mean keratometry steep was 44.39 ± 3.14 vs 46.53 ± 2.13 D preoperatively (P = .02). Mean central corneal thickness decreased from 501.74 ± 13.11 to 475.93 ± 12.25 µm following combined non-topography-guided PRK and CXL (P < .001). No intraoperative complications occurred. Four eyes developed mild haze that responded well to a short course of topical steroids. No eye developed infectious keratitis. Combined non-topography-guided PRK and CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with early stable keratoconus. Copyright 2014, SLACK Incorporated.

  5. How predictable are the results of excimer laser photorefractive keratectomy? A review.

    PubMed

    Grosvenor, T

    1995-10-01

    At the close of 1994, the AOA News reported that at least 14 companies were preparing to market equipment for excimer laser photorefractive keratectomy (PRK). More than a dozen PRK centers had been formed for the purpose of recruiting optometrists to co-manage PRK patients. Because the surgery is a "no-touch" computer-driven procedure whose duration is measured in seconds, the preoperative and postoperative care of PRK patients will assume major importance. Optometrists who will be asked to take part in the management of PRK patients must be able to counsel patients on matters such as the predictability of the procedure in terms of postoperative refractive error and visual acuity, as well as the possibility of unintended consequences such as difficulty in night driving. Information currently available, mainly as a result of studies conducted in other countries, shows that the results of PRK are highly predictable for preoperative myopia up to about -3.00 D and somewhat less predictable for myopia between -3.00 and -6.00 D, whereas for myopia greater than -6.00 D the probability of achieving a full correction decreases rapidly with increasing amounts of myopia. As compared to radial keratotomy (RK) in which the postoperative refractive error drifts relentlessly in the hyperopic direction, PRK brings about an initial hyperopic shift followed by regression leading to increasing myopia. Researchers disagree on the cause of the postoperative hyperopic shift and regression, and on the value of various methods of controlling regression including the use of wider and deeper ablation profiles and the postoperative use of corticosteroids and nonsteroid anti-inflammatory drugs. It is too early to determine whether the myopic creep in PRK will be as persistent as the hyperopic creep in RK, but it is likely that whereas presbyopic post-RK patients may have adequate distance vision but require corrective lenses for reading, presbyopic post-PRK patients may be sufficiently myopic to require lenses for distance vision but not for reading.

  6. [Epidemiology of refractive errors].

    PubMed

    Wolfram, C

    2017-07-01

    Refractive errors are very common and can lead to severe pathological changes in the eye. This article analyzes the epidemiology of refractive errors in the general population in Germany and worldwide and describes common definitions for refractive errors and clinical characteristics for pathologicaal changes. Refractive errors differ between age groups due to refractive changes during the life time and also due to generation-specific factors. Current research about the etiology of refractive errors has strengthened the influence of environmental factors, which led to new strategies for the prevention of refractive pathologies.

  7. An evaluation of the accuracy of the ORange (Gen II) by comparing it to the IOLMaster in the prediction of postoperative refraction.

    PubMed

    Chen, Ming

    2012-01-01

    The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). The Surgical Suites, Honolulu, HI. The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalent refraction from IOLMaster(®) (Carl Zeiss AG, Oberkochen, Germany) and ORange Gen II were statistically compared and verified with 1-month postoperative manifest refraction. The data were put into IBM SPSS 19 (SPSS Inc, Chicago, IL) for analysis of variance. Pearson's correlation coefficient was also calculated to evaluate the correlation between the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction. There were no statistically significant differences in the mean spherical equivalent refraction from the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction (IOLMaster -0.40 diopters, P = 0.07; ORange Gen II -0.43 diopters, P = 0.16; 1-month refraction -0.41 diopters, P = 0.07). Pearson's correlation study demonstrated that all three were positively correlated (P < 0.05), with the strongest correlation between the ORange Gen II and 1-month postoperative manifest refraction (r = +0.6, P < 0.01). The ORange Gen II can be considered as an alternative method for intraocular lens selection for cataract patients.

  8. Visual and refractive outcomes of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-q excimer lasers: a prospective, contralateral study.

    PubMed

    Mearza, Ali A; Muhtaseb, Mohammed; Aslanides, Ioannis M

    2008-11-01

    To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.

  9. Simultaneous and sequential implantation of intacs and verisyse phakic intraocular lens for refractive improvement in keratectasia.

    PubMed

    Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D

    2011-02-01

    To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.

  10. Refractive improvements and safety with topography-guided corneal crosslinking for keratoconus: 1-year results.

    PubMed

    Nordström, Maria; Schiller, Maria; Fredriksson, Anneli; Behndig, Anders

    2017-07-01

    To assess the refractive improvements and the corneal endothelial safety of an individualised topography-guided regimen for corneal crosslinking in progressive keratoconus. An open-label prospective randomised clinical trial was performed at the Department of Clinical Sciences, Ophthalmology, Umeå University Hospital, Umeå, Sweden. Thirty-seven patients (50 eyes) with progressive keratoconus planned for corneal crosslinking were included. The patients were randomised to topography-guided crosslinking (photorefractive intrastromal crosslinking (PiXL); n=25) or uniform 9 mm crosslinking (corneal collagen crosslinking (CXL); n=25). Visual acuity, refraction, keratometry (K1, K2 and K max ) and corneal endothelial morphometry were assessed preoperatively and at 1, 3, 6 and 12 months postoperatively. The PiXL treatment involved an asymmetrical treatment zone centred on the area of maximum corneal steepness with treatment energies ranging from 7.2 to 15.0 J/cm 2 ; the CXL treatment was a uniform 9 mm 5.4 J/cm 2 pulsed crosslinking. The main outcome measures were changes in refractive errors and corneal endothelial cell density. The spherical refractive errors decreased (p<0.05) and the visual acuity improved (p<0.01) at 3, 6 and 12 months after PiXL, but not after CXL. The between-groups differences, however, were not significant. K2 and K max decreased at 3, 6 and 12 months after PiXL (p<0.01), but not after CXL (p<0.01 when comparing the two treatments). No corneal endothelial cell loss was seen after either treatment. Individualised topography-based crosslinking treatment centred on the ectatic cone has the potential to improve the corneal shape in keratoconus with decreased spherical refractive errors and improved visual acuity, without damage to the corneal endothelium. NCT02514200, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Acute acquired comitant esotropia related to excessive Smartphone use.

    PubMed

    Lee, Hyo Seok; Park, Sang Woo; Heo, Hwan

    2016-04-09

    To describe the clinical characteristics and outcomes of acute acquired comitant esotropia (AACE) related to excessive smartphone use in adolescents. The medical records of 12 patients with AACE and a history of excessive smartphone use were retrospectively reviewed, and the duration of smartphone use, angle of deviation, refractive error, stereopsis, and treatment options were analyzed. All patients showed convergent and comitant esotropia ranging from 15 to 45 prism diopters (PD; average: 27.75 ± 11.47 PD) at far fixation. The angle of deviation was nearly equivalent for far and near fixation. Every patient used a smartphone for more than 4 h a day over a period of several months (minimum 4 months). Myopic refractive errors were detected in eight patients (average:-3.84 ± 1.68 diopters (D]), and the remaining four patients showed mild hyperopic refractive error (average: +0.84 ± 0.53 D). Reductions in esodeviation were noted in all patients after refraining from smartphone use, and bilateral medial rectus recession was performed in three patients with considerable remnant esodeviation. Postoperative exams showed orthophoria with good stereoacuity in these patients. Excessive smartphone use might influence AACE development in adolescents. Refraining from smartphone use can decrease the degree of esodeviation in these patients, and remnant deviation can be successfully managed with surgical correction.

  12. Headaches associated with refractive errors: myth or reality?

    PubMed

    Gil-Gouveia, R; Martins, I P

    2002-04-01

    Headache and refractive errors are very common conditions in the general population, and those with headache often attribute their pain to a visual problem. The International Headache Society (IHS) criteria for the classification of headache includes an entity of headache associated with refractive errors (HARE), but indicates that its importance is widely overestimated. To compare overall headache frequency and HARE frequency in healthy subjects with uncorrected or miscorrected refractive errors and a control group. We interviewed 105 individuals with uncorrected refractive errors and a control group of 71 subjects (with properly corrected or without refractive errors) regarding their headache history. We compared the occurrence of headache and its diagnosis in both groups and assessed its relation to their habits of visual effort and type of refractive errors. Headache frequency was similar in both subjects and controls. Headache associated with refractive errors was the only headache type significantly more common in subjects with refractive errors than in controls (6.7% versus 0%). It was associated with hyperopia and was unrelated to visual effort or to the severity of visual error. With adequate correction, 72.5% of the subjects with headache and refractive error reported improvement in their headaches, and 38% had complete remission of headache. Regardless of the type of headache present, headache frequency was significantly reduced in these subjects (t = 2.34, P =.02). Headache associated with refractive errors was rarely identified in individuals with refractive errors. In those with chronic headache, proper correction of refractive errors significantly improved headache complaints and did so primarily by decreasing the frequency of headache episodes.

  13. Comparison of Astigmatic Correction after Femtosecond Lenticule Extraction and Small-Incision Lenticule Extraction for Myopic Astigmatism

    PubMed Central

    Kobashi, Hidenaga; Kamiya, Kazutaka; Ali, Mohamed A.; Igarashi, Akihito; Elewa, Mohamed Ehab M.; Shimizu, Kimiya

    2015-01-01

    Purpose To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism. Methods We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical refraction, the predictability of the astigmatic correction, and the astigmatic vector components using Alpin’s method, were compared between the two groups 3 months postoperatively. Results We found no statistically significant difference in manifest cylindrical refraction (p=0.74) or in the percentage of eyes within ± 0.50 D of their refraction (p=0.47) after the two surgical procedures. Moreover, no statistically significant difference was detected between the groups in astigmatic vector components, namely, surgically induced astigmatism (0.80), target induced astigmatism (p=0.87), astigmatic correction index (p=0.77), angle of error (p=0.24), difference vector (p=0.76), index of success (p=0.91), flattening effect (p=0.79), and flattening index (p=0.84). Conclusions Both FLEx and SMILE procedures are essentially equivalent in correcting myopic astigmatism using vector analysis, suggesting that the lifting or non-lifting of the flap does not significantly affect astigmatic outcomes after these surgical procedures. PMID:25849381

  14. Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration.

    PubMed

    Amselem, Luis; Diaz-Llopis, Manuel; Felipe, Adelina; Artigas, Jose M; Navea, Amparo; García-Delpech, Salvador

    2008-09-01

    To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Ophthalmology Department, Hospital General Universitario, Valencia, Spain. This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postoperative complications. Residual refraction and eye magnification were calculated using a theory developed in a previous study, and the values were compared with the clinical results. The mean BCVA was 1.37 logMAR preoperatively and 0.68 logMAR 1 year postoperatively. The mean best corrected clinical gain was 44%. There was no statistically significant difference between the clinically evaluated and theoretically calculated residual refractions (P = .17). No intraoperative or postoperative complications occurred. Implantation of the double IOL system improved BCVA in patients with low vision due to advanced maculopathy. The results were best in myopic patients (long eyes); patients with hyperopia (short eyes) had high residual refraction. The postoperative clinical gain and residual refraction were predictable, showing the feasibility of implanting a customized double IOL.

  15. Initial resident refractive surgical experience: outcomes of PRK and LASIK for myopia.

    PubMed

    Wagoner, Michael D; Wickard, Joseph C; Wandling, George R; Milder, Lisa C; Rauen, Matthew P; Kitzmann, Anna S; Sutphin, John E; Goins, Kenneth M

    2011-03-01

    To evaluate and compare the outcome of initial resident surgical experience with photorefractive keratectomy (PRK) and LASIK. Retrospective review of all cases performed with the VISX Star S4 platform (Abbott Medical Optics) between July 1, 2003 and June 30, 2007. Inclusion criteria were spherical equivalent of -0.50 to -10.00 diopters (D), refractive astigmatic error of ≤3.00 D, intention to provide full distance correction, and minimum 3-month postoperative follow-up after initial ablation or retreatment (if performed). A total of 153 cases performed by 20 different residents met the inclusion criteria; 38 eyes underwent PRK and 115 eyes had LASIK. After initial treatment, mean Snellen uncorrected distance visual acuity (UDVA) after PRK was 20/17.3 and after LASIK was 20/19.5. Photorefractive keratectomy was associated with a significantly better approximation between preoperative corrected distance visual acuity (CDVA) and postoperative UDVA (ΔlogMAR 0.009 vs 0.091; P=.004) and a greater percentage of eyes that achieved UDVA of 20/20 or better (94.7% vs 78.3%; P=.02) or 20/30 or better (100% vs 87.8%; P=.02). There was a higher prevalence of retreatment in eyes that underwent LASIK (7.0% vs 0%; P=.20). One (0.9%) eye lost 2 lines of CDVA after LASIK. Supervised refractive surgery residents can achieve excellent visual outcomes in patients operated during their initial refractive experience. Photorefractive keratectomy was associated with better visual outcome than LASIK. Copyright 2011, SLACK Incorporated.

  16. The distribution of refractive errors among children attending Lumbini Eye Institute, Nepal.

    PubMed

    Rai, S; Thapa, H B; Sharma, M K; Dhakhwa, K; Karki, R

    2012-01-01

    Uncorrected refractive error is an important cause of childhood blindness and visual impairment. To describe the patterns of refractive errors among children attending the outpatient clinic at the Department of Pediatric Ophthalmology, Lumbini Eye Institute, Bhairahawa, Nepal. Records of 133 children with refractive errors aged 5 - 15 years from both the urban and rural areas of Nepal and the adjacent territory of India attending the hospital between September and November 2010 were examined for patterns of refractive errors. The SPSS statistical software was used to perform data analysis. The commonest type of refractive error among the children was astigmatism (47 %) followed by myopia (34 %) and hyperopia (15 %). The refractive error was more prevalent among children of both the genders of age group 11-15 years as compared to their younger counterparts (RR = 1.22, 95 % CI = 0.66 - 2.25). The refractive error was more common (70 %) in the rural than the urban children (26 %). The rural females had a higher (38 %) prevalence of myopia than urban females (18 %). Among the children with refractive errors, only 57 % were using spectacles at the initial presentation. Astigmatism is the commonest type of refractive error among the children of age 5 - 15 years followed by hypermetropia and myopia. Refractive error remains uncorrected in a significant number of children. © NEPjOPH.

  17. [Character of refractive errors in population study performed by the Area Military Medical Commission in Lodz].

    PubMed

    Nowak, Michał S; Goś, Roman; Smigielski, Janusz

    2008-01-01

    To determine the prevalence of refractive errors in population. A retrospective review of medical examinations for entry to the military service from The Area Military Medical Commission in Lodz. Ophthalmic examinations were performed. We used statistic analysis to review the results. Statistic analysis revealed that refractive errors occurred in 21.68% of the population. The most commen refractive error was myopia. 1) The most commen ocular diseases are refractive errors, especially myopia (21.68% in total). 2) Refractive surgery and contact lenses should be allowed as the possible correction of refractive errors for military service.

  18. Ophthalmic applications of the digital micromirror device (DMD)

    NASA Astrophysics Data System (ADS)

    Reiley, Daniel J.; Sandstedt, Chris

    2009-02-01

    Cataract surgery with IOL implantation is performed on millions of patients every year. Despite 25 years of technological innovation, post-surgical refractive errors have remained a problem. Now these errors can be corrected using Calhoun Vision, Inc's light adjustable lens (LAL). The correction is accomplished by implanting a light-sensitive lens, then illuminating it with a spatially varying irradiance profile during a postoperative treatment. This irradiance profile is provided by a Light Delivery Device (LDD), which projects an image of a Texas Instruments DMD onto the implanted lens. Commercial sales of this system began in the summer of 2008 in Europe; US clinical trials began in January 2009.

  19. The effect of previous soft contact lens wear on corneal refractive surgery outcomes.

    PubMed

    Lloyd-McKernan, Aoife; Simo Mannion, Luisa; O'Dwyer, Veronica

    2017-10-01

    To examine the influence of previous soft contact lens (SCL) wear on corneal refractive surgery (CRS) outcomes when SCL wear is ceased for two weeks versus twenty-four hours, and also when compared to no wear, prior to CRS. A retrospective examination of CRS patient records was carried out for two groups of patients- who ceased SCL wear for two weeks (n=45) and for twenty-four hours (n=49) prior to CRS and compared to a non-contact lens (NCL) control group (n=45 and n=49, respectively). CRS outcomes (efficacy, predictability, visual acuity and refractive error) were compared pre-operatively and one and six months post-operatively. One month post-operative results found unaided distance visual acuity (UDVA) was significantly better for LASEK/PRK patients who had ceased SCL wear for two weeks prior to CRS (-0.05±0.09), compared with the NCL group (0.02±0.09; p=0.04). Furthermore, six month post-operative results found UDVA was significantly better for both LASIK and LASEK/PRK patients who had ceased SCL wear for two weeks prior to CRS, and for LASEK/PRK patients who had ceased SCL wear for twenty-four hours prior to CRS compared with the NCL group. Given the current setup and methods followed, it was concluded that previous SCL wear had no negative impact on visual outcomes following CRS compared with a NCL control group, regardless of previous SCL cessation time prior to CRS. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

    PubMed

    2009-01-01

    The objective of this analysis is to review the effectiveness, safety, and cost-effectiveness of phakic intraocular lenses (pIOLs) for the treatment of myopia, hyperopia, and astigmatism. CONDITION AND TARGET POPULATION REFRACTIVE ERRORS: Refractive errors occur when the eye cannot focus light properly. In myopia (near- or short-sightedness), distant objects appear blurry because the axis of the eye is too long or the cornea is too steep, so light becomes focused in front of the retina. Hyperopia (far sightedness) occurs when light is focused behind the retina causing nearby objects to appear blurry. In astigmatism, blurred or distorted vision occurs when light is focused at two points rather than one due to an irregularly shaped cornea or lens. Refractive errors are common worldwide, but high refractive errors are less common. In the United States, the prevalence of high myopia (≤ -5 D) in people aged 20 to 39, 40 to 59, and 60 years and older is 7.4% (95% confidence interval [CI], 6.5% - 8.3%), 7.8% (95% CI, 6.4% - 8.6%), and 3.1% (95% CI, 2.2% - 3.9%), respectively. The prevalence of high hyperopia (≥ 3 D) is 1.0% (95% CI, .6% - 1.4%), 2.4% (95% CI, 1.7% - 3.0%), and 10.0% (95% CI, 9.1% - 10.9%) for the same age groupings. Finally, the prevalence of astigmatism (≥ 1 D cylinder) is 23.1% (95% CI, 21.6% - 24.5%), 27.6% (95% CI, 25.8% - 29.3%) and 50.1% (48.2% - 52.0%). LOW VISION: According to the Ontario Schedule of Benefits, low visual acuity is defined by a best spectacle corrected visual acuity (BSCVA) of 20/50 (6/15) or less in the better eye and not amenable to further medical and/or surgical treatment. Similarly, the Ontario Assistive Devices Program defines low vision as BSCVA in the better eye in the range of 20/70 or less that cannot be corrected medically, surgically, or with ordinary eyeglasses or contact lenses. Estimates of the prevalence of low vision vary. Using the criteria of BSCVA ranging from 20/70 to 20/160, one study estimated that 35.6 per 10,000 people in Canada have low vision. The 2001 Participation and Activity Limitation Survey (PALS) found that 594,350 (2.5%) Canadians had "difficulty seeing ordinary newsprint or clearly seeing the face of someone from 4 m," and the Canadian National Institute for the Blind (CNIB) registry classified 105,000 (.35%) Canadians as visually disabled. PHAKIC INTRAOCULAR LENSES (PIOL): A phakic intraocular lens (pIOL) is a supplementary lens that is inserted into the anterior or posterior chamber of the eye to correct refractive errors (myopia, hyperopia, and astigmatism). Unlike in cataract surgery, the eye's natural crystalline lens is not removed when the pIOL is inserted, so the eye retains its accommodative ability. In Canada and the United States, iris-fixated (anterior chamber lenses that are anchored to the iris with a claw) and posterior chamber lenses are the only types of pIOLs that are licensed by Health Canada and the Food and Drug Administration, respectively. EVIDENCE-BASED ANALYSIS METHOD: RESEARCH QUESTIONS #ENTITYSTARTX00026; What are the effectiveness, cost-effectiveness, and safety of pIOLs for the treatment of myopia, hyperopia, and astigmatism?Do certain subgroups (e.g. high myopia and low vision) benefit more from pIOLs?How do pIOLs compare with alternative surgical treatment options (LASIK, PRK, and CLE)?Using appropriate keywords, a literature search was conducted up to January 2009. Systematic reviews, meta-analyses, randomized controlled trials, and observational studies with more than 20 eyes receiving pIOLs were eligible for inclusion. The primary outcomes of interest were uncorrected visual acuity (UCVA), predictability of manifest refraction spherical equivalent (MRSE), and adverse events. The GRADE approach was used to systematically and explicitly evaluate the quality of evidence. The search identified 1,131 citations published between January 1, 2003, and January 16, 2009. Including a health technology assessment (HTA) identified in the bibliography review, 30 studies met the inclusion criteria: two HTAs; one systematic review; 20 pre-post observational studies; and seven comparative studies (five pIOL vs. LASIK, one pIOL vs. PRK, and one pIOL vs. CLE). Both HTAs concluded that there was good evidence of the short-term efficacy and safety of pIOLs, however, their conclusions regarding long-term safety differed. The 2006 HTA found convincing evidence of long-term safety, while the 2009 HTA found no long-term evidence about the risks of complications including cataract development, corneal damage, and retinal detachment. The systematic review of adverse events found that cataract development (incidence rate of 9.6% of eyes) is a substantial risk following posterior chamber pIOL implantation, while chronic endothelial cell loss is a safety concern after iris-fixated pIOL implantation. Adverse event rates varied by lens type, but they were more common in eyes that received posterior chamber pIOLs. The evidence of pIOL effectiveness is based on pre-post case series. These studies reported a variety of outcomes and different follow-up time points. It was difficult to combine the data into meaningful summary measures as many time points are based on a single study with a very small sample size. Overall, the efficacy evidence is low to very low quality based on the GRADE Working Group Criteria. For all refractive errors (low to high), most eyes experienced a substantial increase in uncorrected visual acuity (UCVA) with more than 75% of eyes achieving UCVA of 20/40 or better at all postoperative time points. The proportion of eyes that achieved postoperative UCVA 20/20 or better varied substantially according type of lens used and the type of refractive error being corrected, ranging from about 30% of eyes that received iris-fixated lenses for myopia to more than 78% of eyes that received posterior chamber toric lenses for myopic astigmatism. Predictability of manifest refraction spherical equivalent (MRSE) within ± 2.0 D was very high (≥ 90%) for all types of lenses and refractive error. At most time points, more than 50% of eyes achieved a MRSE within ± 0.5 D of emmetropia and at least 85% within ± 1.0 D. Predictability was lower for eyes with more severe preoperative refractive errors. The mean postoperative MRSE was less than 1.0 D in all but two studies. Safety, defined as a loss of two or more Snellen lines of best spectacle corrected visual acuity (BSCVA), was high for all refractive errors and lens types. Losses of two or more lines of BSCVA were uncommon, occurring in fewer than 2% of eyes that had received posterior chamber pIOLs for myopia, and less than 1% of eyes that received iris-fixated lens implantation for myopia. Most eyes did not experience a clinically significant change in BSCVA (i.e. loss of one line, no change, or gain of one line), but 10% to 20% of eyes gained two or more lines of BSCVA. The pIOL outcomes for UCVA, predictability, BSCVA, and adverse events were compared with FDA targets and safety values for refractive surgery and found to meet or exceed these targets at most follow-up time points. The results were then stratified to examine the efficacy of pIOLs for high refractive errors. There was limited data for many outcomes and time points, but overall the results were similar to those for all levels of refractive error severity. The studies that compared pIOLs with LASIK, PRK, and CLE for patients with moderate to high myopia and myopic astigmatism showed that pIOLs performed better than these alternative surgical options for the outcomes of: UCVA,predictability and stability of MRSE,postoperative MRSE,safety (measured as clinically significant loss of BSCVA), andgains in BSCVA.Correction of refractive cylinder (astigmatism) was the only outcome that favoured refractive surgery over pIOLs. This was observed for both toric and non-toric pIOLs (toric pIOLs correct for astigmatism, non-toric pIOLs do not). Common adverse events in the LASIK groups were diffuse lamellar keratitis and striae in the corneal flap. In the pIOL groups, lens repositioning and lens opacities (both asymptomatic and visually significant cataracts) were the most commonly observed adverse events. These studies were determined to be of low to very low evidence quality based on the GRADE Working Group Criteria. Eye, myopia, hyperopia, astigmatism, phakic intraocular lens, LASIK, PRK, uncorrected visual acuity, best corrected visual acuity, refractive errors, clear lens extraction.

  1. Femtosecond laser-assisted cataract surgeries reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery: Baseline characteristics, surgical procedure, and outcomes.

    PubMed

    Lundström, Mats; Dickman, Mor; Henry, Ype; Manning, Sonia; Rosen, Paul; Tassignon, Marie-José; Young, David; Stenevi, Ulf

    2017-12-01

    To describe a large cohort of femtosecond laser-assisted cataract surgeries in terms of baseline characteristics and the related outcomes. Eighteen cataract surgery clinics in 9 European countries and Australia. Prospective multicenter case series. Data on consecutive eyes having femtosecond laser-assisted cataract surgery in the participating clinics were entered in the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). A trained registry manager in each clinic was responsible for valid reporting to the EUREQUO. Demographics, preoperative corrected distance visual acuity (CDVA), risk factors, type of surgery, type of intraocular lens, visual outcomes, refractive outcomes, and complications were reported. Complete data were available for 3379 cases. The mean age was 64.4 years ± 10.9 (SD) and 57.8% (95% confidence interval [CI], 56.1-59.5) of the patients were women. A surgical complication was reported in 2.9% of all cases (95% CI, 2.4-3.5). The mean postoperative CDVA was 0.04 ± 0.15. logarithm of the minimum angle of resolution. A biometry prediction error (spherical equivalent) was within ±0.5 diopter in 71.8% (95% CI, 70.3-73.3) of all surgeries. Postoperative complications were reported in 3.3% (95% CI, 2.7-4.0). Patients with good preoperative CDVA had the best visual and refractive outcomes; patients with poor preoperative visual acuity had poorer outcomes. The visual and refractive outcomes of femtosecond laser-assisted cataract surgery were favorable compared with manual phacoemulsification. The outcomes were highly influenced by the preoperative visual acuity, but all preoperative CDVA groups had acceptable outcomes. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Refractive errors in Aminu Kano Teaching Hospital, Kano Nigeria.

    PubMed

    Lawan, Abdu; Eme, Okpo

    2011-12-01

    The aim of the study is to retrospectively determine the pattern of refractive errors seen in the eye clinic of Aminu Kano Teaching Hospital, Kano-Nigeria from January to December, 2008. The clinic refraction register was used to retrieve the case folders of all patients refracted during the review period. Information extracted includes patient's age, sex, and types of refractive error. All patients had basic eye examination (to rule out other causes of subnormal vision) including intra ocular pressure measurement and streak retinoscopy at two third meter working distance. The final subjective refraction correction given to the patients was used to categorise the type of refractive error. Refractive errors was observed in 1584 patients and accounted for 26.9% of clinic attendance. There were more females than males (M: F=1.0: 1.2). The common types of refractive errors are presbyopia in 644 patients (40%), various types of astigmatism in 527 patients (33%), myopia in 216 patients (14%), hypermetropia in 171 patients (11%) and aphakia in 26 patients (2%). Refractive errors are common causes of presentation in the eye clinic. Identification and correction of refractive errors should be an integral part of eye care delivery.

  3. Outcomes and projected impact on vision restoration of the China Million Cataract Surgeries Program.

    PubMed

    Yan, Xixi; Guan, Chunhong; Mueller, Andreas; Iezzi, Beatrice; He, Mingguang; Liang, Hui; Meltzer, Mirjam; Congdon, Nathan G

    2013-10-01

    The recently completed Chinese "Million Cataract Surgeries Program" (MCSP) is among the largest such campaigns ever, providing 1.05 million operations. We report MCSP outcomes for the first time, in Jiangxi, the province with the greatest program output. Ten county hospitals participating in MCSP were selected in Jiangxi (range of gross domestic product per capita US$743-2998). Each hospital sought to enroll 75 consecutive MCSP patients aged ≥ 50 years. Data recorded included type of cataract procedure, bilateral uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), and refractive error pre- and ≥ 50 days postoperatively. Among 715 patients (mean age 72.3 ± 9.1 years, 55.5% female), preoperative UCVA was <3/60 (legally blind) bilaterally in 13.3% and unilaterally in the operated eye in 50.9%. No subjects had UCVA >6/18 preoperatively. Small incision cataract surgery was performed in 92.3% patients. Among 662 patients (92.6%) completing follow-up was ≥ 40 days after surgery, BCVA was ≥ 6/18 in 80.1%, UCVA was ≥ 6/18 in 57.1% and UCVA was <3/60 in 2.1%. Older age (p < 0.001), female sex (p = 0.04), worse refractive error (p = 0.02) and presence of intra- (p = 0.002) and postoperative surgical complications (p < 0.001), were independently associated with worse postoperative UCVA. Based on these results, the MCSP cured an estimated 124,950 cases (13.3% × [100-2.1%] × 1.05 million) of bilateral and 502,500 (50.9% × [100-2.1%] × 1.05 million) of unilateral blindness. Due to relatively good outcomes and the large number of surgeries performed on blind persons, the sight-restoring impact of the MCSP was probably substantial.

  4. Refractive errors in presbyopic patients in Kano, Nigeria.

    PubMed

    Lawan, Abdu; Okpo, Eme; Philips, Ebisike

    2014-01-01

    The study is a retrospective review of the pattern of refractive errors in presbyopic patients seen in the eye clinic from January to December, 2009. The clinic refraction register was used to retrieve the case folders of all patients refracted during the review period. Information extracted includes patient's age, sex, and types of refractive error. Unaided and pin hole visual acuity was done with Snellen's or "E" Charts and near vision with Jaeger's chart in English or Hausa. All patients had basic eye examination and streak retinoscopy at two third meter working distance. The final subjective refractive correction given to the patients was used to categorize the type of refractive error. There were 5893 patients, 1584 had refractive error and 644 were presbyopic. There were 289 males and 355 females (M:F= 1:1.2). Presbyopia accounted for 10.9% of clinic attendance and 40% of patients with refractive error. Presbyopia was seen in 17%, the remaining 83% required distance correction; astigmatism was seen in 41%, hypermetropia 29%, myopia 9% and aphakia 4%. Refractive error was commoner in females than males and the relationship was statistically significant (P-value = 0.017; P < 0.05 considered significant). Presbyopia is common and most of the patients had other refractive errors. Full refraction is advised for all patients.

  5. Achieving target refraction after cataract surgery.

    PubMed

    Simon, Shira S; Chee, Yewlin E; Haddadin, Ramez I; Veldman, Peter B; Borboli-Gerogiannis, Sheila; Brauner, Stacey C; Chang, Kenneth K; Chen, Sherleen H; Gardiner, Matthew F; Greenstein, Scott H; Kloek, Carolyn E; Chen, Teresa C

    2014-02-01

    To evaluate the difference between target and actual refraction after phacoemulsification and intraocular lens implantation at an academic teaching institution's Comprehensive Ophthalmology Service. Retrospective study. We examined 1275 eye surgeries for this study. All consecutive cataract surgeries were included if they were performed by an attending or resident surgeon from January through December 2010. Postoperative refractions were compared with preoperative target refractions. Patients were excluded if they did not have a preoperative target refraction documented or if they did not have a recorded postoperative manifest refraction within 90 days. The main outcome measure was percentage of cases achieving a postoperative spherical equivalent ± 1.0 diopter (D) of target spherical equivalent. We performed 1368 cataract surgeries from January through December of 2010. Of these, 1275 (93%) had sufficient information for analysis. Of the included cases, 94% (1196 of 1275) achieved ± 1.0 D of target refraction by 90 days after cataract surgery. This paper establishes a new benchmark for a teaching hospital, where 94% of patients achieved within 1.0 D of target refraction after cataract surgery. The refractive outcomes after cataract surgery at this academic teaching institution were higher than average international benchmarks. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Optical Coherence Tomography Accurately Measures Corneal Power Change From Laser Refractive Surgery

    PubMed Central

    McNabb, Ryan P.; Farsiu, Sina; Stinnett, Sandra S.; Izatt, Joseph A.; Kuo, Anthony N.

    2014-01-01

    Purpose To determine the ability of motion corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to laser in situ keratomileusis (LASIK). Design Evaluation of a diagnostic test or technology in a cohort. Subjects 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the post-operative month 3 visit. Change in pre- to post-operative corneal refractive power as measured by each of the imaging modalities was compared to the pre- to post-operative change in manifest refraction using t-test with generalized estimating equations. Main Outcome Measures Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug Photography, and OCT compared to the manifest refraction change vertexed to the corneal plane. The change in manifest refraction should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results In 22 returning post-LASIK individuals (39 eyes), we found no significant difference between the clinically measured pre to post LASIK change in manifest refraction and both Scheimpflug photography (p = 0.714) and OCT (p = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (p < 0.001). Additionally, of the three imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusion Motion corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. PMID:25487424

  7. PREVALENCE OF REFRACTIVE ERRORS IN MADRASSA STUDENTS OF HARIPUR DISTRICT.

    PubMed

    Atta, Zoia; Arif, Abdus Salam; Ahmed, Iftikhar; Farooq, Umer

    2015-01-01

    Visual impairment due to refractive errors is one of the most common problems among school-age children and is the second leading cause of treatable blindness. The Right to Sight, a global initiative launched by a coalition of non-government organizations and the World Health Organization (WHO), aims to eliminate avoidable visual impairment and blindness at a global level. In order to achieve this goal it is important to know the prevalence of different refractive errors in a community. Children and teenagers are the most susceptible groups to be affected by refractive errors. So, this population needs to be screened for different types of refractive errors. The study was done with the objective to find the frequency of different types of refractive errors in students of madrassas between the ages of 5-20 years in Haripur. This cross sectional study was done with 300 students between ages of 5-20 years in Madrassas of Haripur. The students were screened for refractive errors and the types of the errors were noted. After screening for refractive errors-the glasses were prescribed to the students. Myopia being 52.6% was the most frequent refractive error in students, followed by hyperopia 28.4% and astigmatism 19%. This study showed that myopia is an important problem in madrassa population. Females and males are almost equally affected. Spectacle correction of refractive errors is the cheapest and easy solution of this problem.

  8. Prevalence and risk factors of undercorrected refractive errors among Singaporean Malay adults: the Singapore Malay Eye Study.

    PubMed

    Rosman, Mohamad; Wong, Tien Y; Tay, Wan-Ting; Tong, Louis; Saw, Seang-Mei

    2009-08-01

    To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting and best corrected visual acuities. Distance presenting visual acuity was monocularly measured by using a logarithm of the minimum angle of resolution (logMAR) number chart at a distance of 4 m, with the participants wearing their "walk-in" optical corrections (spectacles or contact lenses), if any. Refraction was determined by subjective refraction by trained, certified study optometrists. Best corrected visual acuity was monocularly assessed and recorded in logMAR scores using the same test protocol as was used for presenting visual acuity. Undercorrected refractive error was defined as an improvement of at least 0.2 logMAR (2 lines equivalent) in the best corrected visual acuity compared with the presenting visual acuity in the better eye. The mean age of the subjects included in our study was 58 +/- 11 years, and 52% of the subjects were women. The prevalence rate of undercorrected refractive error among Singaporean Malay adults in our study (n = 3115) was 20.4% (age-standardized prevalence rate, 18.3%). More of the women had undercorrected refractive error than the men (21.8% vs. 18.8%, P = 0.04). Undercorrected refractive error was also more common in subjects older than 50 years than in subjects aged 40 to 49 years (22.6% vs. 14.3%, P < 0.001). Non-spectacle wearers were more likely to have undercorrected refractive errors than were spectacle wearers (24.4% vs. 14.4%, P < 0.001). Persons with primary school education or less were 1.89 times (P = 0.03) more likely to have undercorrected refractive errors than those with post-secondary school education or higher. In contrast, persons with a history of eye disease were 0.74 times (P = 0.003) less likely to have undercorrected refractive errors. The proportion of undercorrected refractive error among the Singaporean Malay adults with refractive errors was higher than that of the Singaporean Chinese adults with refractive errors. Undercorrected refractive error is a significant cause of correctable visual impairment among Singaporean Malay adults, affecting one in five persons.

  9. Contralateral comparison of wavefront-guided LASIK surgery with iris recognition versus without iris recognition using the MEL80 Excimer laser system.

    PubMed

    Wu, Fang; Yang, Yabo; Dougherty, Paul J

    2009-05-01

    To compare outcomes in wavefront-guided LASIK performed with iris recognition software versus without iris recognition software in different eyes of the same patient. A randomised, prospective study of 104 myopic eyes of 52 patients undergoing LASIK surgery with the MEL80 excimer laser system was performed. Iris recognition software was used in one eye of each patient (study group) and not used in the other eye (control group). Higher order aberrations (HOAs), contrast sensitivity, uncorrected vision (UCV), visual acuity (VA) and corneal topography were measured and recorded pre-operatively and at one month and three months post-operatively for each eye. The mean post-operative sphere and cylinder between groups was similar, however the post-operative angles of error (AE) by refraction were significantly smaller in the study group compared to the control group both in arithmetic and absolute means (p = 0.03, p = 0.01). The mean logMAR UCV was significantly better in the study group than in the control group at one month (p = 0.01). The mean logMAR VA was significantly better in the study group than in control group at both one and three months (p = 0.01, p = 0.03). In addition, mean trefoil, total third-order aberration, total fourth-order aberration and the total scotopic root-mean-square (RMS) HOAs were significantly less in the study group than those in the control group at the third (p = 0.01, p = 0.05, p = 0.04, p = 0.02). By three months, the contrast sensitivity had recovered in both groups but the study group performed better at 2.6, 4.2 and 6.6 cpd (cycles per degree) than the control group (p = 0.01, p < 0.01, p = 0.01). LASIK performed with iris recognition results in better VA, lower mean higher-order aberrations, lower refractive post-operative angles of error and better contrast sensitivity at three months post-operatively than LASIK performed without iris recognition.

  10. Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

    PubMed

    Visser, Nienke; Beckers, Henny J M; Bauer, Noel J C; Gast, Sacha T J M; Zijlmans, Bart L M; Berenschot, Tos T J M; Webers, Carroll A; Nuijts, Rudy M M A

    2014-12-01

    Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. A multicenter, hospital-based, randomized clinical trial was conducted. The participants included 86 individuals with bilateral cataract and bilateral corneal astigmatism of at least 1.25 diopters (D) who were randomized to receive either bilateral toric (n = 41) or bilateral control (n = 45) IOL implantation. Bilateral implantation of an aspherical toric IOL or an aspherical control IOL. Spectacle independency for distance vision, uncorrected distance visual acuity, refractive astigmatism, contrast sensitivity, wavefront aberrations, and refractive error-related quality-of-life questionnaire. Preoperatively, mean (SD) corneal astigmatism was 2.02 (0.95) D and 2.00 (0.84) D in the toric and control groups, respectively. Four patients (5%) were lost to follow-up. At 6 months postoperatively, 26 (70%) of the patients in the toric group achieved an uncorrected distance visual acuity of 20/25 or better compared with 14 (31%) in the control group (P < .001; odds ratio, 5.23; 95% CI, 2.03-13.48). Spectacle independency for distance vision was achieved in 31 patients (84%) in the toric group compared with 14 patients (31%) in the control group (P < .001; odds ratio, 11.44; 95% CI, 3.89- 33.63). Mean refractive astigmatism was -0.77 (0.52) D and -1.89 D (1.00) D, respectively. Vector analysis of toric IOLs showed a mean magnitude of error of +0.38 D, indicative of overcorrection. No significant differences were found in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life. In patients with cataract and corneal astigmatism, bilateral toric IOL implantation results in a higher spectacle independency for distance vision compared with bilateral control IOL implantation. No significant differences were identified in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life following both treatments. clinicaltrials.gov Identifier: NCT01075542.

  11. Comparison of Accuracy in Intraocular Lens Power Calculation by Measuring Axial Length with Immersion Ultrasound Biometry and Partial Coherence Interferometry.

    PubMed

    Ruangsetakit, Varee

    2015-11-01

    To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.

  12. Profile of refractive errors in cerebral palsy: impact of severity of motor impairment (GMFCS) and CP subtype on refractive outcome.

    PubMed

    Saunders, Kathryn J; Little, Julie-Anne; McClelland, Julie F; Jackson, A Jonathan

    2010-06-01

    To describe refractive status in children and young adults with cerebral palsy (CP) and relate refractive error to standardized measures of type and severity of CP impairment and to ocular dimensions. A population-based sample of 118 participants aged 4 to 23 years with CP (mean 11.64 +/- 4.06) and an age-appropriate control group (n = 128; age, 4-16 years; mean, 9.33 +/- 3.52) were recruited. Motor impairment was described with the Gross Motor Function Classification Scale (GMFCS), and subtype was allocated with the Surveillance of Cerebral Palsy in Europe (SCPE). Measures of refractive error were obtained from all participants and ocular biometry from a subgroup with CP. A significantly higher prevalence and magnitude of refractive error was found in the CP group compared to the control group. Axial length and spherical refractive error were strongly related. This relation did not improve with inclusion of corneal data. There was no relation between the presence or magnitude of spherical refractive errors in CP and the level of motor impairment, intellectual impairment, or the presence of communication difficulties. Higher spherical refractive errors were significantly associated with the nonspastic CP subtype. The presence and magnitude of astigmatism were greater when intellectual impairment was more severe, and astigmatic errors were explained by corneal dimensions. Conclusions. High refractive errors are common in CP, pointing to impairment of the emmetropization process. Biometric data support this In contrast to other functional vision measures, spherical refractive error is unrelated to CP severity, but those with nonspastic CP tend to demonstrate the most extreme errors in refraction.

  13. Survey of Radar Refraction Error Corrections

    DTIC Science & Technology

    2016-11-01

    ELECTRONIC TRAJECTORY MEASUREMENTS GROUP RCC 266-16 SURVEY OF RADAR REFRACTION ERROR CORRECTIONS DISTRIBUTION A: Approved for...DOCUMENT 266-16 SURVEY OF RADAR REFRACTION ERROR CORRECTIONS November 2016 Prepared by Electronic...This page intentionally left blank. Survey of Radar Refraction Error Corrections, RCC 266-16 iii Table of Contents Preface

  14. Comparison of clinical outcomes of iris fixation and scleral fixation as treatment for intraocular lens dislocation.

    PubMed

    Kim, Kyeong Hwan; Kim, Wan Soo

    2015-09-01

    To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation.

    PubMed

    Zhang, Lijun; Sy, Mary Ellen; Mai, Harry; Yu, Fei; Hamilton, D Rex

    2015-01-01

    To compare the prediction error after toric intraocular lens (IOL) (Acrysof IQ) implantation using corneal astigmatism measurements obtained with an IOLMaster automated keratometer and a Galilei dual rotating camera Scheimpflug-Placido tomographer. Jules Stein Eye Institute, University of California Los Angeles, Los Angeles, California, USA. Retrospective case series. The predicted residual astigmatism after toric IOL implantation was calculated using preoperative astigmatism values from an automated keratometer and the total corneal power (TCP) determined by ray tracing through the measured anterior and posterior corneal surfaces using dual Scheimpflug-Placido tomography. The prediction error was calculated as the difference between the predicted astigmatism and the manifest astigmatism at least 1 month postoperatively. The calculations included vector analysis. The study evaluated 35 eyes (35 patients). The preoperative corneal posterior astigmatism mean magnitude was 0.33 diopter (D) ± 0.16 (SD) (vector mean 0.23 × 176). Twenty-six eyes (74.3%) had with-the-rule (WTR) posterior astigmatism. The postoperative manifest refractive astigmatism mean magnitude was 0.38 ± 0.18 D (vector mean 0.26 × 171). There was no statistically significant difference in the mean magnitude prediction error between the automated keratometer and TCP techniques. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect against-the-rule (ATR) astigmatism. The TCP technique lacked these biases. The automated keratometer and TCP methods for estimating the magnitude of corneal astigmatism gave similar results. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect ATR astigmatism. Dr. Hamilton has received honoraria for educational lectures from Ziemer Ophthalmic Systems. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Nature of the refractive errors in rhesus monkeys (Macaca mulatta) with experimentally induced ametropias.

    PubMed

    Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-Su; Ramamirtham, Ramkumar; Smith, Earl L

    2010-08-23

    We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. Nature of the Refractive Errors in Rhesus Monkeys (Macaca mulatta) with Experimentally Induced Ametropias

    PubMed Central

    Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-su; Ramamirtham, Ramkumar; Smith, Earl L.

    2010-01-01

    We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. PMID:20600237

  18. Single-Step Transepithelial PRK vs Alcohol-Assisted PRK in Myopia and Compound Myopic Astigmatism Correction.

    PubMed

    Kaluzny, Bartlomiej J; Cieslinska, Iwona; Mosquera, Samuel A; Verma, Shwetabh

    2016-02-01

    Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK).This prospective, nonrandomized, case-control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive results, predictability, safety, and efficacy were evaluated during the 3-month follow-up. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and mean refractive spherical equivalent (MRSE).Mean preoperative MRSE was -4.30 ± 1.72 D and -4.33 ± 1.96 D, respectively (P = 0.87). The 3-month follow-up rate was 82.1% in the tPRK group (n = 145) and 86.4% in aaPRK group (n = 90), P = 0.81. Postoperative UDVA was 20/20 or better in 97% and 94% of eyes, respectively (P = 0.45). In the tPRK and aaPRK groups, respectively, 13% and 21% of eyes lost 1 line of CDVA, and 30% and 31% gained 1 or 2 lines (P = 0.48). Mean postoperative MRSE was -0.14 ± 0.26 D in the tPRK group and -0.12 ± 0.20 D in the aaPRK group (P = 0.9). The correlation between attempted versus achieved MRSE was equally high in both groups.Single-step transepithelial PRK and conventional PRK provide very similar results 3 months postoperatively. These procedures are predictable, effective, and safe for correction of myopia and compound myopic astigmatism.

  19. Atmospheric refraction effects on baseline error in satellite laser ranging systems

    NASA Technical Reports Server (NTRS)

    Im, K. E.; Gardner, C. S.

    1982-01-01

    Because of the mathematical complexities involved in exact analyses of baseline errors, it is not easy to isolate atmospheric refraction effects; however, by making certain simplifying assumptions about the ranging system geometry, relatively simple expressions can be derived which relate the baseline errors directly to the refraction errors. The results indicate that even in the absence of other errors, the baseline error for intercontinental baselines can be more than an order of magnitude larger than the refraction error.

  20. Pattern of refractive errors among the Nepalese population: a retrospective study.

    PubMed

    Shrestha, S P; Bhat, K S; Binu, V S; Barthakur, R; Natarajan, M; Subba, S H

    2010-01-01

    Refractive errors are a major cause of visual impairment in the population. To find the pattern of refractive errors among patients evaluated in a tertiary care hospital in the western region of Nepal. The present hospital-based retrospective study was conducted in the Department of Ophthalmology of the Manipal Teaching Hospital, situated in Pokhara, Nepal. Patients who had refractive error of at least 0.5 D (dioptre) were included for the study. During the study period, 15,410 patients attended the outpatient department and 10.8% of the patients were identified as having refractive error. The age of the patients in the present study ranged between 5 - 90 years. Myopia was the commonest refractive error followed by hypermetropia. There was no difference in the frequency of the type of refractive errors when they were defined using right the eye, the left eye or both the eyes. Males predominated among myopics and females predominated among hypermetropics. The majority of spherical errors was less than or equal to 2 D. Astigmatic power above 1D was rarely seen with hypermetropic astigmatism and was seen in around 13 % with myopic astigmatism. "Astigmatism against the rule" was more common than "astigmatism with the rule", irrespective of age. Refractive errors progressively shift along myopia up to the third decade and change to hypermetropia till the seventh decade. Hyperopic shift in the refractive error in young adults should be well noted while planning any refractive surgery in younger patients with myopia. © Nepal Ophthalmic Society.

  1. Corneal modeling for analysis of photorefractive keratectomy

    NASA Astrophysics Data System (ADS)

    Della Vecchia, Michael A.; Lamkin-Kennard, Kathleen

    1997-05-01

    Procedurally, excimer photorefractive keratectomy is based on the refractive correction of composite spherical and cylindrical ophthalmic errors of the entire eye. These refractive errors are inputted for correction at the corneal plane and for the properly controlled duration and location of laser energy. Topography is usually taken to correspondingly monitor spherical and cylindrical corneorefractive errors. While a corneal topographer provides surface morphologic information, the keratorefractive photoablation is based on the patient's spherical and cylindrical spectacle correction. Topography is at present not directly part of the procedural deterministic parameters. Examination of how corneal curvature at each of the keratometric reference loci affect the shape of the resultant corneal photoablated surface may enhance the accuracy of the desired correction. The objective of this study was to develop a methodology to utilize corneal topography for construction of models depicting pre- and post-operative keratomorphology for analysis of photorefractive keratectomy. Multiple types of models were developed then recreated in optical design software for examination of focal lengths and other optical characteristics. The corneal models were developed using data extracted from the TMS I corneal modeling system (Computed Anatomy, New York, NY). The TMS I does not allow for manipulation of data or differentiation of pre- and post-operative surfaces within its platform, thus models needed to be created for analysis. The data were imported into Matlab where 3D models, surface meshes, and contour plots were created. The data used to generate the models were pre- and post-operative curvatures, heights from the corneal apes, and x-y positions at 6400 locations on the corneal surface. Outlying non-contributory points were eliminated through statistical operations. Pre- and post- operative models were analyzed to obtain the resultant changes in the corneal surfaces during PRK. A sensitivity analysis of the corneal topography system was also performed. Ray tracings were performed using the height data and the optical design software Zemax (Focus Software, Inc., Tucson, AZ). Examining pre- and post-operative values of corneal surfaces may further the understanding of how areas of the cornea contribute toward desired visual correction. Gross resultant power across the corneal surface is used in PRK, however, understanding the contribution of each point to the average power may have important implications and prove to be significant for achieving projected surgical results.

  2. [Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber].

    PubMed

    Yang, Fei; Hou, Xianru; Wu, Huijuan; Bao, Yongzhen

    2014-02-01

    To evaluate the characteristics of postoperative refractive status in age-related cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperative refractive status. Prospective case-control study. Sixty-eight cases (90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases (34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentacam system. Axial length and keratometer were measured by IOL Master and intraocular lens power was calculated using SRK/T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSS13.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. The postoperative refractive deviation at 1 month were (-0.39 ± 0.62) D in control group and (+0.73 ± 0.26) D in shallow anterior chamber group respectively which present statistical significance between the two groups (P = 0.00, t = 3.67); the postoperative refractive deviation in 3 month was (-0.37 ± 0.62) D in control group and (+0.79 ± 0.28) D in shallow anterior chamber group operatively which present statistical significance between the two groups (P = 0.00, t = 3.33). In shallow anterior chamber group, with the shallower of ACD, the greater of refractive deviation (P = 0.00, r1 month = -0.57, r3 months = -0.61). Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.

  3. Uncorrected and corrected refractive error experiences of Nepalese adults: a qualitative study.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Shrestha, Mohan Krishna; Sharma, Sadhana; Neupane Kandel, Sandhya; Dhungana, Purushottam; Pradhan, Kishore; Nepal, Bhagavat P; Thapa, Suman; Pesudovs, Konrad

    2018-04-01

    The aim of this study was to explore the impact of corrected and uncorrected refractive error (URE) on Nepalese people's quality of life (QoL), and to compare the QoL status between refractive error subgroups. Participants were recruited from Tilganga Institute of Ophthalmology and Dhulikhel Hospital, Nepal. Semi-structured in-depth interviews were conducted with 101 people with refractive error. Thematic analysis was used with matrices produced to compare the occurrence of themes and categories across participants. Themes were identified using an inductive approach. Seven major themes emerged that determined refractive error-specific QoL: activity limitation, inconvenience, health concerns, psycho-social impact, economic impact, general and ocular comfort symptoms, and visual symptoms. Activity limitation, economic impact, and symptoms were the most important themes for the participants with URE, whereas inconvenience associated with wearing glasses was the most important issue in glasses wearers. Similarly, possibilities of having side effects or complications were the major concerns for participants wearing contact lens. In general, refractive surgery addressed socio-emotional impact of wearing glasses or contact lens. However, the surgery participants had concerns such as possibility of having to wear glasses again due to relapse of refractive error. Impact of refractive error on people's QoL is multifaceted. Significance of the identified themes varies by refractive error subgroups. Refractive correction may not always address QoL impact of URE but often add unique QoL issues. This study findings also provide content for developing an item-bank for quantitatively measuring refractive error-specific QoL in developing country setting.

  4. Refractive errors among children, adolescents and adults attending eye clinics in Mexico.

    PubMed

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P <0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population.

  5. Refractive errors among children, adolescents and adults attending eye clinics in Mexico

    PubMed Central

    Gomez-Salazar, Francisco; Campos-Romero, Abraham; Gomez-Campaña, Humberto; Cruz-Zamudio, Cinthia; Chaidez-Felix, Mariano; Leon-Sicairos, Nidia; Velazquez-Roman, Jorge; Flores-Villaseñor, Hector; Muro-Amador, Secundino; Guadron-Llanos, Alma Marlene; Martinez-Garcia, Javier J.; Murillo-Llanes, Joel; Sanchez-Cuen, Jaime; Llausas-Vargas, Alejando; Alapizco-Castro, Gerardo; Irineo-Cabrales, Ana; Graue-Hernandez, Enrique; Ramirez-Luquin, Tito; Canizalez-Roman, Adrian

    2017-01-01

    AIM To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. METHODS Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE), as follows: sphere+½ cylinder. Myopia (SE>-0.50 D), hyperopia (SE>+0.50 D), emmetropia (-0.50≤SE≤+0.50), and astigmatism alone (cylinder≥-0.25 D). A negative cylinder was selected as a notation. RESULTS The proportion (95% confidence interval) among all of the subjects was hyperopia 21.0% (20.9-21.0), emmetropia 40.7% (40.5-40.8), myopia 24.8% (24.7-24.9) and astigmatism alone 13.5% (13.4-13.5). Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old), however, hyperopia increased among the aging population (40 to 79 years old), and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%). There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older). The proportion of any clinically important refractive error was higher in males (61.2%) than in females (58.3%; P<0.0001). From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. CONCLUSION Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population. PMID:28546940

  6. Refractive Errors Affect the Vividness of Visual Mental Images

    PubMed Central

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  7. Refractive errors affect the vividness of visual mental images.

    PubMed

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception.

  8. Uncorrected refractive errors.

    PubMed

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship.

  9. Refractive errors and schizophrenia.

    PubMed

    Caspi, Asaf; Vishne, Tali; Reichenberg, Abraham; Weiser, Mark; Dishon, Ayelet; Lubin, Gadi; Shmushkevitz, Motti; Mandel, Yossi; Noy, Shlomo; Davidson, Michael

    2009-02-01

    Refractive errors (myopia, hyperopia and amblyopia), like schizophrenia, have a strong genetic cause, and dopamine has been proposed as a potential mediator in their pathophysiology. The present study explored the association between refractive errors in adolescence and schizophrenia, and the potential familiality of this association. The Israeli Draft Board carries a mandatory standardized visual accuracy assessment. 678,674 males consecutively assessed by the Draft Board and found to be psychiatrically healthy at age 17 were followed for psychiatric hospitalization with schizophrenia using the Israeli National Psychiatric Hospitalization Case Registry. Sib-ships were also identified within the cohort. There was a negative association between refractive errors and later hospitalization for schizophrenia. Future male schizophrenia patients were two times less likely to have refractive errors compared with never-hospitalized individuals, controlling for intelligence, years of education and socioeconomic status [adjusted Hazard Ratio=.55; 95% confidence interval .35-.85]. The non-schizophrenic male siblings of schizophrenia patients also had lower prevalence of refractive errors compared to never-hospitalized individuals. Presence of refractive errors in adolescence is related to lower risk for schizophrenia. The familiality of this association suggests that refractive errors may be associated with the genetic liability to schizophrenia.

  10. Effect of refractive error on temperament and character properties.

    PubMed

    Kalkan Akcay, Emine; Canan, Fatih; Simavli, Huseyin; Dal, Derya; Yalniz, Hacer; Ugurlu, Nagihan; Gecici, Omer; Cagil, Nurullah

    2015-01-01

    To determine the effect of refractive error on temperament and character properties using Cloninger's psychobiological model of personality. Using the Temperament and Character Inventory (TCI), the temperament and character profiles of 41 participants with refractive errors (17 with myopia, 12 with hyperopia, and 12 with myopic astigmatism) were compared to those of 30 healthy control participants. Here, temperament comprised the traits of novelty seeking, harm-avoidance, and reward dependence, while character comprised traits of self-directedness, cooperativeness, and self-transcendence. Participants with refractive error showed significantly lower scores on purposefulness, cooperativeness, empathy, helpfulness, and compassion (P<0.05, P<0.01, P<0.05, P<0.05, and P<0.01, respectively). Refractive error might have a negative influence on some character traits, and different types of refractive error might have different temperament and character properties. These personality traits may be implicated in the onset and/or perpetuation of refractive errors and may be a productive focus for psychotherapy.

  11. [Refractive errors in patients with cerebral palsy].

    PubMed

    Mrugacz, Małgorzata; Bandzul, Krzysztof; Kułak, Wojciech; Poppe, Ewa; Jurowski, Piotr

    2013-04-01

    Ocular changes are common in patients with cerebral palsy (CP) and they exist in about 50% of cases. The most common are refractive errors and strabismus disease. The aim of the paper was to estimate the relativeness between refractive errors and neurological pathologies in patients with selected types of CP. MATERIAL AND METHODS. The subject of the analysis was showing refractive errors in patients within two groups of CP: diplegia spastica and tetraparesis, with nervous system pathologies taken into account. Results. This study was proven some correlations between refractive errors and type of CP and severity of the CP classified in GMFCS scale. Refractive errors were more common in patients with tetraparesis than with diplegia spastica. In the group with diplegia spastica more common were myopia and astigmatism, however in tetraparesis - hyperopia.

  12. A survey of the prevalence of refractive errors among children in lower primary schools in Kampala district.

    PubMed

    Kawuma, Medi; Mayeku, Robert

    2002-08-01

    Refractive errors are a known cause of visual impairment and may cause blindness worldwide. In children, refractive errors may prevent those afflicted from progressing with their studies. In Uganda, like in many developing countries, there is no established vision-screening programme for children on commencement of school, such that those with early onset of such errors will have many years of poor vision. Over all, there is limited information on refractive errors among children in Africa. To determine the prevalence of refractive errors among school children attending lower primary in Kampala district; the frequency of the various types of refractive errors, and their relationship to sexuality and ethnicity. A cross-sectional descriptive study. Kampala district, Uganda A total of 623 children aged between 6 and 9 years had a visual acuity testing done at school using the same protocol; of these 301 (48.3%) were boys and 322 (51.7%) girls. Seventy-three children had a significant refractive error of +/-0.50 or worse in one or both eyes, giving a prevalence of 11.6% and the commonest single refractive error was astigmatism, which accounted for 52% of all errors. This was followed by hypermetropia, and myopia was the least common. Significant refractive errors occur among primary school children aged 6 to 9 years at a prevalence of approximately 12%. Therefore, there is a need to have regular and simple vision testing in primary school children at least at the commencement of school so as to defect those who may suffer from these disabilities.

  13. Headache and refractive errors in children.

    PubMed

    Roth, Zachary; Pandolfo, Katie R; Simon, John; Zobal-Ratner, Jitka

    2014-01-01

    To investigate the association between uncorrected or miscorrected refractive errors in children and headache, and to determine whether correction of refractive errors contributes to headache resolution. Results of ophthalmic examination, including refractive error, were recorded at initial visit for headache. If resolution of headache on subsequent visits was not documented, a telephone call was placed to their caregivers to inquire whether headache had resolved. Of the 158 patients, 75.3% had normal or unchanged eye examinations, including refractions.Follow-up data were available for 110 patients. Among those, 32 received new or changed spectacle correction and 78 did not require a change in refraction.Headaches improved in 76.4% of all patients, whether with (71.9%) or without (78.2%) a change in refractive correction. The difference between these two groups was not statistically significant (P = .38). Headaches in children usually do not appear to be caused by ophthalmic disease, including refractive error. The prognosis for improvement is favorable, regardless of whether refractive correction is required. Copyright 2014, SLACK Incorporated.

  14. Corneal haze following PRK with mitomycin C as a retreatment versus prophylactic use in the contralateral eye.

    PubMed

    Netto, Marcelo V; Chalita, Maria Regina; Krueger, Ronald R

    2007-01-01

    To report photorefractive keratectomy (PRK) treated with mitomycin C (MMC) for previous corneal haze in one eye and PRK with MMC to prevent corneal haze formation in the fellow eye. A 40-year-old woman underwent PRK with MMC to treat previous corneal haze (secondary to previous PRK without MMC) for residual refractive error of +0.50 +0.25 x 165 in the left eye and PRK with MMC to prevent corneal haze in the right eye. Postoperative slit-lamp examination revealed no haze in the right eye, but continued mild haze in the left eye. Treatment with PRK and MMC for previous corneal haze is not as effective as primary PRK with MMC in preventing postoperative corneal haze formation.

  15. Complications after procedures of photorefractive keratectomy

    NASA Astrophysics Data System (ADS)

    Gierek-Ciaciura, Stanislawa

    1998-10-01

    Purpose: The aim of this study was to investigate the saveness of the PRK procedures. Material and method: 151 eyes after PRK for correction of myopia and 112 after PRK for correction of myopic astigmatism were examined. All PRK procedures have been performed with an excimer laser manufactured by Aesculap Meditec. Results: Haze, regression, decentration infection and overcorrection were found. Conclusions: The most often complication is regression. Corneal inflammation in the early postoperative period may cause the regression or haze. The greater corrected refractive error the greater haze degree. Haze decreases with time.

  16. Refractive Errors

    MedlinePlus

    ... and lens of your eye helps you focus. Refractive errors are vision problems that happen when the shape ... cornea, or aging of the lens. Four common refractive errors are Myopia, or nearsightedness - clear vision close up ...

  17. Comparison of DLK incidence after laser in situ keratomileusis associated with two femtosecond lasers: Femto LDV and IntraLase FS60

    PubMed Central

    Tomita, Minoru; Sotoyama, Yuko; Yukawa, Satoshi; Nakamura, Tadayuki

    2013-01-01

    Purpose To compare the incidence of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) with flap creation using the Femto LDV and IntraLase™ FS60 femtosecond lasers.0 Methods A total of 818 consecutive myopic eyes had LASIK performed using either Femto LDV or IntraLase FS60 for flap creation. The same excimer laser, the Allegretto Wave® Eye-Q Laser, was used for correcting refractive errors for all patients. In the preoperative examination, uncorrected distance visual acuity, corrected distance visual acuity, and manifest refraction spherical equivalent were measured. At the postop examination, the same examinations were performed along with a slit-lamp biomicroscopic examination, and patients with DLK were classified into stages. For the statistical analysis of the DLK occurrence rate and the visual and refractive outcomes, the Mann-Whitney’s U-test was used. Results In the Femto LDV group with 514 eyes, 42 (8.17%) had DLK. In the IntraLase FS60 group with 304 eyes, 114 (37.5%) had DLK. There was a statistically significant difference in the DLK incidence rate between these groups (P < 0.0001). Both groups had excellent visual and refractive outcomes. Although low levels of DLK were observed for both groups, they did not affect visual acuity. Conclusion While there were significantly fewer incidences of low level DLK when using Femto LDV, neither femtosecond laser induced high levels of DLK, and any postoperative DLK cleared up within 1 week. Therefore, both lasers provide excellent results, with no clinical differences, and both excel at flap creation for LASIK. PMID:23874077

  18. Comparison of single-step reverse transepithelial all-surface laser ablation (ASLA) to alcohol-assisted photorefractive keratectomy.

    PubMed

    Aslanides, Ioannis M; Padroni, Sara; Arba Mosquera, Samuel; Ioannides, Antonis; Mukherjee, Achyut

    2012-01-01

    To evaluate postoperative pain, corneal epithelial healing, development of corneal haze, refractive outcomes, and corneal aberrations in a novel one-step, modified transepithelial photorefractive keratectomy (PRK), termed All-surface laser ablation (ASLA), compared to conventional, alcohol-assisted PRK. Sixty eyes of 30 myopic patients were prospectively recruited to a randomized fellow eye study. Patients underwent conventional alcohol-assisted PRK in one eye (control group) and ASLA-modified transepithelial PRK in the other (30 eyes in each treatment arm). Primary endpoints were postoperative pain and haze scores at 1 day, 3 days, 1 week, and 1, 3, 6, and 12 months. Secondary endpoints included visual acuity at 1, 3, 6, and 12 months, corneal aberrations at 3, 6, and 12 months, and early and late onset haze. Refractive predictability, safety, and efficacy of the two methods were considered. The average age of the cohort was 29 years (standard deviation [SD]: 9; range: 18-46), and the average spherical equivalent refractive error was -4.18 diopters (SD: 1.9). At 3 days after surgery, the average pain score was 64% lower in the ASLA group (P < 0.0005). At this point, 96% of ASLA eyes had no epithelial defect, whereas 43% in the alcohol-assisted group did not achieve complete epithelial healing, and required replacement of bandage contact lens. The haze level was consistently lower in the ASLA group at all time points from 1 to 6 months. This study shows that the ASLA technique may have a future role in refractive surgery, due to the fact that it offers faster epithelial healing, lower pain scores, and significantly less haze formation.

  19. Comparison of single-step reverse transepithelial all-surface laser ablation (ASLA) to alcohol-assisted photorefractive keratectomy

    PubMed Central

    Aslanides, Ioannis M; Padroni, Sara; Mosquera, Samuel Arba; Ioannides, Antonis; Mukherjee, Achyut

    2012-01-01

    Purpose To evaluate postoperative pain, corneal epithelial healing, development of corneal haze, refractive outcomes, and corneal aberrations in a novel one-step, modified transepithelial photorefractive keratectomy (PRK), termed All-surface laser ablation (ASLA), compared to conventional, alcohol-assisted PRK. Materials and methods Sixty eyes of 30 myopic patients were prospectively recruited to a randomized fellow eye study. Patients underwent conventional alcohol-assisted PRK in one eye (control group) and ASLA-modified transepithelial PRK in the other (30 eyes in each treatment arm). Primary endpoints were postoperative pain and haze scores at 1 day, 3 days, 1 week, and 1, 3, 6, and 12 months. Secondary endpoints included visual acuity at 1, 3, 6, and 12 months, corneal aberrations at 3, 6, and 12 months, and early and late onset haze. Refractive predictability, safety, and efficacy of the two methods were considered. Results The average age of the cohort was 29 years (standard deviation [SD]: 9; range: 18–46), and the average spherical equivalent refractive error was −4.18 diopters (SD: 1.9). At 3 days after surgery, the average pain score was 64% lower in the ASLA group (P < 0.0005). At this point, 96% of ASLA eyes had no epithelial defect, whereas 43% in the alcohol-assisted group did not achieve complete epithelial healing, and required replacement of bandage contact lens. The haze level was consistently lower in the ASLA group at all time points from 1 to 6 months. Conclusion This study shows that the ASLA technique may have a future role in refractive surgery, due to the fact that it offers faster epithelial healing, lower pain scores, and significantly less haze formation. PMID:22815640

  20. Risk factors for refractive errors in primary school children (6-12 years old) in Nakhon Pathom Province.

    PubMed

    Yingyong, Penpimol

    2010-11-01

    Refractive error is one of the leading causes of visual impairment in children. An analysis of risk factors for refractive error is required to reduce and prevent this common eye disease. To identify the risk factors associated with refractive errors in primary school children (6-12 year old) in Nakhon Pathom province. A population-based cross-sectional analytic study was conducted between October 2008 and September 2009 in Nakhon Pathom. Refractive error, parental refractive status, and hours per week of near activities (studying, reading books, watching television, playing with video games, or working on the computer) were assessed in 377 children who participated in this study. The most common type of refractive error in primary school children was myopia. Myopic children were more likely to have parents with myopia. Children with myopia spend more time at near activities. The multivariate odds ratio (95% confidence interval)for two myopic parents was 6.37 (2.26-17.78) and for each diopter-hour per week of near work was 1.019 (1.005-1.033). Multivariate logistic regression models show no confounding effects between parental myopia and near work suggesting that each factor has an independent association with myopia. Statistical analysis by logistic regression revealed that family history of refractive error and hours of near-work were significantly associated with refractive error in primary school children.

  1. Population-based assessment of sensitivity and specificity of a pinhole for detection of significant refractive errors in the community.

    PubMed

    Marmamula, Srinivas; Keeffe, Jill E; Narsaiah, Saggam; Khanna, Rohit C; Rao, Gullapalli N

    2014-11-01

    Measurements of refractive errors through subjective or automated refraction are not always possible in rapid assessment studies and community vision screening programs; however, measurements of vision with habitual correction and with a pinhole can easily be made. Although improvements in vision with a pinhole are assumed to mean that a refractive error is present, no studies have investigated the magnitude of improvement in vision with pinhole that is predictive of refractive error. The aim was to measure the sensitivity and specificity of 'vision improvement with pinhole' in predicting the presence of refractive error in a community setting. Vision and vision with pinhole were measured using a logMAR chart for 488 of 582 individuals aged 15 to 50 years. Refractive errors were measured using non-cycloplegic autorefraction and subjective refraction. The presence of refractive error was defined using spherical equivalent refraction (SER) at two levels: SER greater than ± 0.50 D sphere (DS) and SER greater than ±1.00 DS. Three definitions for significant improvement in vision with a pinhole were used: 1. Presenting vision less than 6/12 and improving to 6/12 or better, 2. Improvement in vision of more than one logMAR line and 3. Improvement in vision of more than two logMAR lines. For refractive error defined as spherical equivalent refraction greater than ± 0.50 DS, the sensitivities and specificities for the pinhole test predicting the presence of refractive error were 83.9 per cent (95% CI: 74.5 to 90.9) and 98.8 per cent (95% CI: 97.1 to 99.6), respectively for definition 1. Definition 2 had a sensitivity 89.7 per cent (95% CI: 81.3 to 95.2) and specificity 88.0 per cent (95% CI: 4.4 to 91.0). Definition 3 had a sensitivity of 75.9 per cent (95% CI: 65.5 to 84.4) and specificity of 97.8 per cent (95% CI: 95.8 to 99.0). Similar results were found with spherical equivalent refraction greater than ±1.00 DS, when tested against the three pinhole-based definitions. Refractive error definitions based on improvement in vision with the pinhole shows good sensitivity and specificity at predicting the presence of significant refractive errors. These definitions can be used in rapid assessment surveys and community-based vision screenings. © 2014 The Authors. Clinical and Experimental Optometry © 2014 Optometrists Association Australia.

  2. A clinic-based study of refractive errors, strabismus, and amblyopia in pediatric age-group.

    PubMed

    Al-Tamimi, Elham R; Shakeel, Ayisha; Yassin, Sanaa A; Ali, Syed I; Khan, Umar A

    2015-01-01

    The purpose of this cross-sectional observational study was to determine the distribution and patterns of refractive errors, strabismus, and amblyopia in children seen at a pediatric eye care. The study was conducted in a Private Hospital in Dammam, Kingdom of Saudi Arabia, from March to July 2013. During this period, a total of 1350 children, aged 1-15 years were seen at this Center's Pediatric Ophthalmology Unit. All the children underwent complete ophthalmic examination with cycloplegic refraction. Refractive errors accounted for 44.4% of the cases, the predominant refractive error being hypermetropia which represented 83%. Strabismus and amblyopia were present in 38% and 9.1% of children, respectively. In this clinic-based study, the focus was on the frequency of refractive errors, strabismus, and amblyopia which were considerably high. Hypermetropia was the predominant refractive error in contrast to other studies in which myopia was more common. This could be attributed to the criteria for sample selection since it was clinic-based rather than a population-based study. However, it is important to promote public education on the significance of early detection of refractive errors, and have periodic screening in schools.

  3. Uncorrected refractive errors

    PubMed Central

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship. PMID:22944755

  4. Generalized ray tracing method for the calculation of the peripheral refraction induced by an ophthalmic lens

    NASA Astrophysics Data System (ADS)

    Rojo, Pilar; Royo, Santiago; Caum, Jesus; Ramírez, Jorge; Madariaga, Ines

    2015-02-01

    Peripheral refraction, the refractive error present outside the main direction of gaze, has lately attracted interest due to its alleged relationship with the progression of myopia. The ray tracing procedures involved in its calculation need to follow an approach different from those used in conventional ophthalmic lens design, where refractive errors are compensated only in the main direction of gaze. We present a methodology for the evaluation of the peripheral refractive error in ophthalmic lenses, adapting the conventional generalized ray tracing approach to the requirements of the evaluation of peripheral refraction. The nodal point of the eye and a retinal conjugate surface will be used to evaluate the three-dimensional distribution of refractive error around the fovea. The proposed approach enables us to calculate the three-dimensional peripheral refraction induced by any ophthalmic lens at any direction of gaze and to personalize the lens design to the requirements of the user. The complete evaluation process for a given user prescribed with a -5.76D ophthalmic lens for foveal vision is detailed, and comparative results obtained when the geometry of the lens is modified and when the central refractive error is over- or undercorrected. The methodology is also applied for an emmetropic eye to show its application for refractive errors other than myopia.

  5. Comparisons of refractive errors between twins and singletons in Chinese school-age samples.

    PubMed

    Hur, Yoon-Mi; Zheng, Yingfeng; Huang, Wenyong; Ding, Xiaohu; He, Mingguang

    2009-02-01

    Studies have reported that refractive errors are associated with premature births. As twins have higher prevalence of prematurity than singletons, it is important to assess similarity of the prevalence of refractive errors in twins and singletons for proper interpretations and generalizations of the findings from twin studies. We compared refractive errors and diopter hours between 561 pairs of twins and 3757 singletons who are representative of school-age children (7-15 years) residing in an urban area of southern China. We found that the means and variances of the continuous measurement of spherical equivalent refractive error and diopter hours were not significantly different between twins and singletons. Although the prevalence of myopia was comparable between twins and singletons, that of hyperopia and astigmatism was slightly but significantly higher in twins than in singletons. These results are inconsistent with those of adult studies that showed no differences in refractive errors between twins and singletons. Given that the sample size of twins is relatively small and that this study is the first to demonstrate minor differences in refractive errors between twins and singletons, future replications are necessary to determine whether the slightly higher prevalence of refractive errors in twins than in singletons found in this study was due to a sampling error or to the developmental delay often observed in twins in childhood.

  6. The GEnes in Myopia (GEM) study in understanding the aetiology of refractive errors.

    PubMed

    Baird, Paul N; Schäche, Maria; Dirani, Mohamed

    2010-11-01

    Refractive errors represent the leading cause of correctable vision impairment and blindness in the world with an estimated 2 billion people affected. Refractive error refers to a group of refractive conditions including hypermetropia, myopia, astigmatism and presbyopia but relatively little is known about their aetiology. In order to explore the potential role of genetic determinants in refractive error the "GEnes in Myopia (GEM) study" was established in 2004. The findings that have resulted from this study have not only provided greater insight into the role of genes and other factors involved in myopia but have also gone some way to uncovering the aetiology of other refractive errors. This review will describe some of the major findings of the GEM study and their relative contribution to the literature, illuminate where the deficiencies are in our understanding of the development of refractive errors and how we will advance this field in the future. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Refractive errors among students occupying rooms lighted with incandescent or fluorescent lamps.

    PubMed

    Czepita, Damian; Gosławski, Wojciech; Mojsa, Artur

    2004-01-01

    The purpose of the study was to determine whether the development of refractive errors could be associated with exposure to light emitted by incandescent or fluorescent lamps. 3636 students were examined (1638 boys and 1998 girls, aged 6-18 years, mean age 12.1, SD 3.4). The examination included retinoscopy with cycloplegia. Myopia was defined as refractive error < or = -0.5 D, hyperopia as refractive error > or = +1.5 D, astigmatism as refractive error > 0.5 DC. Anisometropia was diagnosed when the difference in the refraction of both eyes was > 1.0 D. The children and their parents completed a questionnaire on exposure to light at home. Data were analyzed statistically with the chi2 test. P values of less than 0.05 were considered statistically significant. It was found that the use of fluorescent lamps was associated with an increase in the occurrence of hyperopia (P < 0.01). There was no association between sleeping with the light turned on and prevalence of refractive errors.

  8. PREVALENCE OF UNCORRECTED REFRACTIVE ERRORS IN ADULTS AGED 30 YEARS AND ABOVE IN A RURAL POPULATION IN PAKISTAN.

    PubMed

    Abdullah, Ayesha S; Jadoon, Milhammad Zahid; Akram, Mohammad; Awan, Zahid Hussain; Azam, Mohammad; Safdar, Mohammad; Nigar, Mohammad

    2015-01-01

    Uncorrected refractive errors are a leading cause of visual disability globally. This population-based study was done to estimate the prevalence of uncorrected refractive errors in adults aged 30 years and above of village Pawakah, Khyber Pakhtunkhwa (KPK), Pakistan. It was a cross-sectional survey in which 1000 individuals were included randomly. All the individuals were screened for uncorrected refractive errors and those whose visual acuity (VA) was found to be less than 6/6 were refracted. In whom refraction was found to be unsatisfactory (i.e., a best corrected visual acuity of <6/6) further examination was done to establish the cause for the subnormal vision. A total of 917 subjects participated in the survey (response rate 92%). The prevalence of uncorrected refractive errors was found to be 23.97% among males and 20% among females. The prevalence of visually disabling refractive errors was 6.89% in males and 5.71% in females. The prevalence was seen to increase with age, with maximum prevalence in 51-60 years age group. Hypermetropia (10.14%) was found to be the commonest refractive error followed by Myopia (6.00%) and Astigmatism (5.6%). The prevalence of Presbyopia was 57.5% (60.45% in males and 55.23% in females). Poor affordability was the commonest barrier to the use of spectacles, followed by unawareness. Cataract was the commonest reason for impaired vision after refractive correction. The prevalence of blindness was 1.96% (1.53% in males and 2.28% in females) in this community with cataract as the commonest cause. Despite being the most easily avoidable cause of subnormal vision uncorrected refractive errors still account for a major proportion of the burden of decreased vision in this area. Effective measures for the screening and affordable correction of uncorrected refractive errors need to be incorpora'ted into the health care delivery system.

  9. Prevalence and pattern of refractive errors among primary school children in Al Hassa , Saudi Arabia.

    PubMed

    Al Wadaani, Fahd Abdullah; Amin, Tarek Tawfik; Ali, Ayub; Khan, Atuar Rahman

    2012-11-11

    Some 12.8 million in the age group 5-15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia.  A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware.

  10. Prevalence and Pattern of Refractive Errors among Primary School Children in Al Hassa, Saudi Arabia

    PubMed Central

    Wadaani, Fahd Abdullah Al; Amin, Tarek Tawfik; Ali, Ayub; Khan, Ataur Rahman

    2013-01-01

    Some 12.8 million in the age group 5–15 years are visually impaired from uncorrected or inadequately corrected refractive errors. In Saudi Arabia, the size of this public health problem is not well defined especially among primary schoolchildren. The purpose of this cross-sectional study was to assess the prevalence and pattern of refractive errors among primary school children in Al Hassa, Saudi Arabia. A total of 2246 Saudi primary school children aged 6 to 14 years of both genders were selected using multistage sampling method form 30 primary schools located in the three different areas of Al Hassa. School children were interviewed to collect demographics and vision data using a special data collection form followed by screening for refractive errors by trained optometrists within the school premises using a standardized protocol. Assessment of visual acuity and ocular motility evaluation were carried out and cover-uncover test was performed. Children detected with defective vision were referred for further examination employing subjective refraction with auto refractometer and objective refraction using streak retinoscopy after 1% cyclopentolate. Of the screened school children (N=2002), the overall prevalence of refractive errors was 13.7% (n=274), higher among females (Odds ratio, OR=1.39, P=0.012) and significantly more among students of rural residence (OR=2.40, P=0.001). The prevalence of refractive errors was disproportionately more among those aged 12-14 years (OR=9.02, P=0.001). Only 9.4% of students with poor vision were wore spectacles for correction. Myopia was the most commonly encountered refractive error among both genders (65.7% of the total errors encountered). Uncorrected refractive errors affected a sizable portion of primary school children in Al Hassa, Saudi Arabia. Primary schoolchildren especially females, rural and older children represents high risk group for refractive errors for which the included children were unaware. PMID:23283044

  11. Refractive error and presbyopia among adults in Fiji.

    PubMed

    Brian, Garry; Pearce, Matthew G; Ramke, Jacqueline

    2011-04-01

    To characterize refractive error, presbyopia and their correction among adults aged ≥ 40 years in Fiji, and contribute to a regional overview of these conditions. A population-based cross-sectional survey using multistage cluster random sampling. Presenting distance and near vision were measured and dilated slitlamp examination performed. The survey achieved 73.0% participation (n=1381). Presenting binocular distance vision ≥ 6/18 was achieved by 1223 participants. Another 79 had vision impaired by refractive error. Three of these were blind. At threshold 6/18, 204 participants had refractive error. Among these, 125 had spectacle-corrected presenting vision ≥ 6/18 ("met refractive error need"); 79 presented wearing no (n=74) or under-correcting (n=5) distance spectacles ("unmet refractive error need"). Presenting binocular near vision ≥ N8 was achieved by 833 participants. At threshold N8, 811 participants had presbyopia. Among these, 336 attained N8 with presenting near spectacles ("met presbyopia need"); 475 presented with no (n=402) or under-correcting (n=73) near spectacles ("unmet presbyopia need"). Rural residence was predictive of unmet refractive error (p=0.040) and presbyopia (p=0.016) need. Gender and household income source were not. Ethnicity-gender-age-domicile-adjusted to the Fiji population aged ≥ 40 years, "met refractive error need" was 10.3% (95% confidence interval [CI] 8.7-11.9%), "unmet refractive error need" was 4.8% (95%CI 3.6-5.9%), "refractive error correction coverage" was 68.3% (95%CI 54.4-82.2%),"met presbyopia need" was 24.6% (95%CI 22.4-26.9%), "unmet presbyopia need" was 33.8% (95%CI 31.3-36.3%), and "presbyopia correction coverage" was 42.2% (95%CI 37.6-46.8%). Fiji refraction and dispensing services should encourage uptake by rural dwellers and promote presbyopia correction. Lack of comparable data from neighbouring countries prevents a regional overview.

  12. Relative peripheral hyperopic defocus alters central refractive development in infant monkeys

    PubMed Central

    Smith, Earl L.; Hung, Li-Fang; Huang, Juan

    2009-01-01

    Understanding the role of peripheral defocus on central refractive development is critical because refractive errors can vary significantly with eccentricity and peripheral refractions have been implicated in the genesis of central refractive errors in humans. Two rearing strategies were used to determine whether peripheral hyperopia alters central refractive development in rhesus monkeys. In intact eyes, lens-induced relative peripheral hyperopia produced central axial myopia. Moreover, eliminating the fovea by laser photoablation did not prevent compensating myopic changes in response to optically imposed hyperopia. These results show that peripheral refractive errors can have a substantial impact on central refractive development in primates. PMID:19632261

  13. Crystalline lens power and refractive error.

    PubMed

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P < 0.001) and nuclear lens opacity grade (β = -0.42; P < 0.001), followed by axial length (β = -0.35; P < 0.001). They were lowest for corneal refractive power (β = -0.08; P = 0.001) and anterior chamber depth (β = -0.05; P = 0.04). In multivariate analysis, refractive error was significantly (P < 0.001) associated with shorter axial length (β = -1.26), lower refractive lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  14. Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery.

    PubMed

    Sano, Maki; Hiraoka, Takahiro; Ueno, Yuta; Itagaki, Hideo; Ogami, Tomohiro; Oshika, Tetsuro

    2016-12-01

    To examine the influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery. The study enrolled 64 pseudophakic eyes of 50 patients (71.8 ± 9.9 years old, mean ± standard deviation) who had undergone phacoemulsification with non-toric IOL implantation. Refractive astigmatism was measured using an auto ref-keratometer with a 0.01- diopter (D) scale. Two types of corneal astigmatism were calculated using anterior segment optical coherence tomography; keratometric and total corneal astigmatism. Keratometric astigmatism was obtained based on anterior corneal curvature alone and total corneal astigmatism was calculated using both anterior and posterior corneal curvatures. The difference between refractive and corneal astigmatism was computed as the vector difference using 1) refractive and keratometric astigmatism and 2) refractive and total corneal astigmatism. The mean refractive, keratometric, and total corneal astigmatism was 0.92 ± 0.48 D, 0.87 ± 0.44 D, and 0.94 ± 0.46 D, respectively. The difference between refractive and keratometric astigmatism (0.70 ± 0.40 D, mean vector of 0.30 D axis 164°) was significantly larger than the difference between refractive and total corneal astigmatism (0.63 ± 0.38 D, mean vector of 0.12 D axis 137°) (P = .019). The difference between refractive and total corneal astigmatism, calculated using both anterior and posterior corneal curvatures, was significantly smaller than the difference between refractive and keratometric astigmatism using anterior corneal astigmatism alone, implying that the latter overestimates the true postoperative refractive astigmatism and can cause cylindrical inaccuracy after cataract surgery.

  15. Five-Year Progression of Refractive Errors and Incidence of Myopia in School-Aged Children in Western China

    PubMed Central

    Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang

    2016-01-01

    Background To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. Methods A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Results Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was −2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of −0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of −0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%–63.5%), with an annual incidence of 10.6% (95% CI, 8.7%–13.1%). Myopia was found more likely to happen in female and older children. Conclusions In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China. PMID:26875599

  16. Five-Year Progression of Refractive Errors and Incidence of Myopia in School-Aged Children in Western China.

    PubMed

    Zhou, Wen-Jun; Zhang, Yong-Ye; Li, Hua; Wu, Yu-Fei; Xu, Ji; Lv, Sha; Li, Ge; Liu, Shi-Chun; Song, Sheng-Fang

    2016-07-05

    To determine the change in refractive error and the incidence of myopia among school-aged children in the Yongchuan District of Chongqing City, Western China. A population-based cross-sectional survey was initially conducted in 2006 among 3070 children aged 6 to 15 years. A longitudinal follow-up study was then conducted 5 years later between November 2011 and March 2012. Refractive error was measured under cycloplegia with autorefraction. Age, sex, and baseline refractive error were evaluated as risk factors for progression of refractive error and incidence of myopia. Longitudinal data were available for 1858 children (60.5%). The cumulative mean change in refractive error was -2.21 (standard deviation [SD], 1.87) diopters (D) for the entire study population, with an annual progression of refraction in a myopic direction of -0.43 D. Myopic progression of refractive error was associated with younger age, female sex, and higher myopic or hyperopic refractive error at baseline. The cumulative incidence of myopia, defined as a spherical equivalent refractive error of -0.50 D or more, among initial emmetropes and hyperopes was 54.9% (95% confidence interval [CI], 45.2%-63.5%), with an annual incidence of 10.6% (95% CI, 8.7%-13.1%). Myopia was found more likely to happen in female and older children. In Western China, both myopic progression and incidence of myopia were higher than those of children from most other locations in China and from the European Caucasian population. Compared with a previous study in China, there was a relative increase in annual myopia progression and annual myopia incidence, a finding which is consistent with the increasing trend on prevalence of myopia in China.

  17. Relative Proportion Of Different Types Of Refractive Errors In Subjects Seeking Laser Vision Correction.

    PubMed

    Althomali, Talal A

    2018-01-01

    Refractive errors are a form of optical defect affecting more than 2.3 billion people worldwide. As refractive errors are a major contributor of mild to moderate vision impairment, assessment of their relative proportion would be helpful in the strategic planning of health programs. To determine the pattern of the relative proportion of types of refractive errors among the adult candidates seeking laser assisted refractive correction in a private clinic setting in Saudi Arabia. The clinical charts of 687 patients (1374 eyes) with mean age 27.6 ± 7.5 years who desired laser vision correction and underwent a pre-LASIK work-up were reviewed retrospectively. Refractive errors were classified as myopia, hyperopia and astigmatism. Manifest refraction spherical equivalent (MRSE) was applied to define refractive errors. Distribution percentage of different types of refractive errors; myopia, hyperopia and astigmatism. The mean spherical equivalent for 1374 eyes was -3.11 ± 2.88 D. Of the total 1374 eyes, 91.8% (n = 1262) eyes had myopia, 4.7% (n = 65) eyes had hyperopia and 3.4% (n = 47) had emmetropia with astigmatism. Distribution percentage of astigmatism (cylinder error of ≥ 0.50 D) was 78.5% (1078/1374 eyes); of which % 69.1% (994/1374) had low to moderate astigmatism and 9.4% (129/1374) had high astigmatism. Of the adult candidates seeking laser refractive correction in a private setting in Saudi Arabia, myopia represented greatest burden with more than 90% myopic eyes, compared to hyperopia in nearly 5% eyes. Astigmatism was present in more than 78% eyes.

  18. Biomechanical and optical behavior of human corneas before and after photorefractive keratectomy.

    PubMed

    Sánchez, Paolo; Moutsouris, Kyros; Pandolfi, Anna

    2014-06-01

    To evaluate numerically the biomechanical and optical behavior of human corneas and quantitatively estimate the changes in refractive power and stress caused by photorefractive keratectomy (PRK). Athineum Refractive Center, Athens, Greece, and Politecnico di Milano, Milan, Italy. Retrospective comparative interventional cohort study. Corneal topographies of 10 human eyes were taken with a scanning-slit corneal topographer (Orbscan II) before and after PRK. Ten patient-specific finite element models were created to estimate the strain and stress fields in the cornea in preoperative and postoperative configurations. The biomechanical response in postoperative eyes was computed by directly modeling the postoperative geometry from the topographer and by reproducing the corneal ablation planned for the PRK with a numerical reprofiling procedure. Postoperative corneas were more compliant than preoperative corneas. In the optical zone, corneal thinning decreased the mechanical stiffness, causing local resteepening and making the central refractive power more sensitive to variations in intraocular pressure (IOP). At physiologic IOP, the postoperative corneas had a mean 7% forward increase in apical displacement and a mean 20% increase in the stress components at the center of the anterior surface over the preoperative condition. Patient-specific numerical models of the cornea can provide quantitative information on the changes in refractive power and in the stress field caused by refractive surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Prevalence of uncorrected refractive errors among school-age children in the School District of Philadelphia.

    PubMed

    Mayro, Eileen L; Hark, Lisa A; Shiuey, Eric; Pond, Michael; Siam, Linda; Hill-Bennett, Tamara; Tran, Judie; Khanna, Nitasha; Silverstein, Marlee; Donaghy, James; Zhan, Tingting; Murchison, Ann P; Levin, Alex V

    2018-06-01

    To determine the prevalence and severity of uncorrected refractive errors in school-age children attending Philadelphia public schools. The Wills Eye Vision Screening Program for Children is a community-based pediatric vision screening program designed to detect and correct refractive errors and refer those with nonrefractive eye diseases for examination by a pediatric ophthalmologist. Between January 2014 and June 2016 the program screened 18,974 children in grades K-5 in Philadelphia public schools. Children who failed the vision screening were further examined by an on-site ophthalmologist or optometrist; children whose decreased visual acuity was not amenable to spectacle correction were referred to a pediatric ophthalmologist. Of the 18,974 children screened, 2,492 (13.1%) exhibited uncorrected refractive errors: 1,776 (9.4%) children had myopia, 459 (2.4%) had hyperopia, 1,484 (7.8%) had astigmatism, and 846 (4.5%) had anisometropia. Of the 2,492 with uncorrected refractive error, 368 children (14.8%) had more than one refractive error diagnosis. In stratifying refractive error diagnoses by severity, mild myopia (spherical equivalent of -0.50 D to < -3.00 D) was the most common diagnosis, present in 1,573 (8.3%) children. In this urban population 13.1% of school-age children exhibited uncorrected refractive errors. Blurred vision may create challenges for students in the classroom; school-based vision screening programs can provide an avenue to identify and correct refractive errors. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  20. Early outcomes after small incision lenticule extraction and photorefractive keratectomy for correction of high myopia

    PubMed Central

    Chan, Tommy C. Y.; Yu, Marco C. Y.; Ng, Alex; Wang, Zheng; Cheng, George P. M.; Jhanji, Vishal

    2016-01-01

    We prospectively compared visual and refractive outcomes in patients with high myopia and myopic astigmatism after small-incision lenticule extraction (SMILE) and photorefractive keratetctomy (PRK) with mitomycin C. Sixty-six eyes of 33 patients (mean age, 29.7 ± 5.6 years) were included (SMILE: 34 eyes, PRK 32 eyes). Preoperatively, no significant difference was noted in manifest spherical equivalent (p = 0.326), manifest sphere (p = 0.277), and manifest cylinder (p = 0.625) between both groups. At 1 month, there were significant differences in logMAR uncorrected distance visual acuity, efficacy index and manifest refraction spherical equivalent between SMILE and PRK (p ≤ 0.029). At 6 months, the logMAR corrected distance visual acuity (p = 0.594), logMAR uncorrected visual acuity (p = 0.452), efficacy index (p = 0.215) and safety index was (p = 0.537) was comparable between SMILE and PRK. Significant differences were observed in postoperative manifest spherical equivalent (p = 0.044) and manifest cylinder (p = 0.014) between both groups. At the end of 6 months, 100% of the eyes in SMILE group and 69% of the eyes in PRK group were within ±0.50 D of the attempted cylindrical correction. The postoperative difference vector, magnitude of error and absolute angle of error were significantly smaller after SMILE compared to PRK (p ≤ 0.040) implying a trend towards overcorrection of cylindrical correction following PRK. PMID:27601090

  1. Outcomes of photorefractive keratectomy enhancement after LASIK.

    PubMed

    Lee, Bryan S; Gupta, Preeya K; Davis, Elizabeth A; Hardten, David R

    2014-08-01

    To report the outcomes of photorefractive keratectomy (PRK) enhancement after LASIK for patients diagnosed as having hyperopic and myopic refractive errors. In this retrospective case series at a single private practice in the United States, all patients undergoing PRK enhancement after LASIK were identified. Patients with visually significant cataract, non-plano targets, and follow-up of fewer than 226 days were excluded. The primary outcome measure was uncorrected distance visual acuity (UDVA) with secondary measures of corrected distance visual acuity (CDVA) and postoperative refractive error. Linear regression analysis was performed for actual versus targeted change in spherical equivalent. Mean UDVA improved from 20/39 to 20/24 for hyperopes (n = 14; P < .002) and from 20/45 to 20/22 for myopes (n = 29; P < .0000001) after enhancement. All patients had a UDVA of 20/40 or better at their most recent follow-up visit. Fifty percent of hyperopes and 65.5% of myopes were 20/20 or better. The mean refractive error for hyperopes changed from +1.10 ± 0.71 (range: +0.13 to +2.25 diopters [D]) to +0.38 ± 0.66 D (range: -0.75 to +1.38 D) and from -1.21 ± 0.61 (range: -3.25 to -0.38 D) to +0.34 ± 0.45 D (range: -0.25 to +1.75 D) for myopes. The manifest refraction cylinder decreased from 0.84 to 0.46 D in hyperopes (P = .02) and from 0.64 to 0.26 D in myopes (P < .002). CDVA was maintained in both groups, with only one patient in each worse than 20/20. There was a nonsignificant trend toward less haze in the patients receiving mitomycin C (5.1% vs 25%, P = .14). Linear regression showed a tendency toward overtreatment in the myopic group. PRK is safe and highly effective for patients who previously underwent LASIK and in whom the surgeon would prefer not to perform a flap-lift enhancement. Copyright 2014, SLACK Incorporated.

  2. Ocular residual astigmatism's effect on high myopic astigmatism LASIK surgery

    PubMed Central

    Teus, M A; Arruabarrena, C; Hernández-Verdejo, J L; Cañones, R; Mikropoulos, D G

    2014-01-01

    Purpose To analyze the effect of ocular residual astigmatism (ORA) on the effectiveness of LASIK for treating high myopic astigmatism. Methods This is an observational, cross-sectional study. We studied 116 consecutive myopic eyes with −3 diopters (D) or more of astigmatism that underwent LASIK surgery. The magnitude of uncorrected residual refractive astigmatism 3 months postoperatively was measured. Results The mean preoperative cylinder was −4.0±0.83 D (range, −7.5 to −3 D) and the mean preoperative ORA was 0.82±0.5 D. The mean residual refractive cylinder 3 months postoperatively was −0.78±0.83 D (range, −3 to 0 D). No correlation was found between ORA and the refractive cylinder 3 months postoperatively (P=0.6). Conclusion In eyes with high myopic astigmatism undergoing LASIK, ORA was not correlated with the residual postoperative cylinder. PMID:24971989

  3. Aspheric photorefractive keratectomy for myopia and myopic astigmatism with the SCHWIND AMARIS laser: 2 years postoperative outcomes

    PubMed Central

    Aslanides, Ioannis M.; Padroni, Sara; Arba-Mosquera, Samuel

    2012-01-01

    Purpose To evaluate mid-term refractive outcomes and higher order aberrations of aspheric PRK for low, moderate and high myopia and myopic astigmatism with the AMARIS excimer laser system (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). Methods This prospective longitudinal study evaluated 80 eyes of 40 subjects who underwent aspheric PRK. Manifest refractive spherical equivalent (MRSE) of up to −10.00 diopters (D) at the spectacle plane with cylinder up to 3.25 was treated. Refractive outcomes and corneal wavefront data (6 mm pupil to the 7th Zernike order) were evaluated out to 2 years postoperatively. Statistical significance was indicated by P < 0.05. Results The mean manifest spherical equivalent refraction (MRSE) was −4.77 ± 2.45 (range, −10.00 D to −0.75 D) preoperatively and −0.12 ± 0.35 D (range, −1.87 D to +0.75 D) postoperatively (P < 0.0001). Postoperatively, 91% (73/80) of eyes had an MRSE within ±0.50 D of the attempted. No eyes lost one or more lines of corrected distance visual acuity (CDVA) and CDVA increased by one or more lines in 26% (21/80) of eyes. Corneal trefoil and corneal higher order aberration root mean square did not statistically change postoperatively compared to preoperatively (P > 0.05, both cases). There was a statistical increase in postoperative coma (+0.12 μm) and spherical aberration (+0.14 μm) compared to preoperatively (P < 0.001, both cases). Conclusion Aspheric PRK provides excellent visual and refractive outcomes with induction in individual corneal aberrations but not overall corneal aberrations.

  4. Patient-reported Outcomes for Assessment of Quality of Life in Refractive Error: A Systematic Review.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Goggin, Michael; Pesudovs, Konrad

    2017-12-01

    This review has identified the best existing patient-reported outcome (PRO) instruments in refractive error. The article highlights the limitations of the existing instruments and discusses the way forward. A systematic review was conducted to identify the types of PROs used in refractive error, to determine the quality of the existing PRO instruments in terms of their psychometric properties, and to determine the limitations in the content of the existing PRO instruments. Articles describing a PRO instrument measuring 1 or more domains of quality of life in people with refractive error were identified by electronic searches on the MEDLINE, PubMed, Scopus, Web of Science, and Cochrane databases. The information on content development, psychometric properties, validity, reliability, and responsiveness of those PRO instruments was extracted from the selected articles. The analysis was done based on a comprehensive set of assessment criteria. One hundred forty-eight articles describing 47 PRO instruments in refractive error were included in the review. Most of the articles (99 [66.9%]) used refractive error-specific PRO instruments. The PRO instruments comprised 19 refractive, 12 vision but nonrefractive, and 16 generic PRO instruments. Only 17 PRO instruments were validated in refractive error populations; six of them were developed using Rasch analysis. None of the PRO instruments has items across all domains of quality of life. The Quality of Life Impact of Refractive Correction, the Quality of Vision, and the Contact Lens Impact on Quality of Life have comparatively better quality with some limitations, compared with the other PRO instruments. This review describes the PRO instruments and informs the choice of an appropriate measure in refractive error. We identified need of a comprehensive and scientifically robust refractive error-specific PRO instrument. Item banking and computer-adaptive testing system can be the way to provide such an instrument.

  5. Study on the refractive errors of school going children of Pokhara city in Nepal.

    PubMed

    Niroula, D R; Saha, C G

    Refractive errors are the one of the most common visual disorders found worldwide in school going children and also it is one of the causes of blindness. It can easily be prevented, if timely proper measures are taken. In Kathmandu valley and Mechi Zone of Nepal, the distribution of refractive errors was found to be very high. No records are available from the Western part of Nepal. Considering the importance of the refractive errors the present study had been undertaken in Pokhara city. 964 subjects (474 boys, 490 girls) were selected between age groups 10 to 19 years from 6 schools representing different region of Pokhara. After Preliminary examination: on acuity of vision with Snellen's and Jaeger's charts, the subjects were referred to the Manipal Teaching Hospital, Pokhara for confirmation of the refractive errors. Sixty two schools children (6.43%), out of 964 had refractive errors. The myopia was found to be most common (4.05%). The refractive errors were found more in Private school children (9.29%) than Government school children (4.23%), which is statistically significant (P < 0.05). More boys (7.59%) were found to have suffered from refractive errors than girls (5.31%). Further, children with vegetarian diet (10.52%) had greater number of refractive errors than non-vegetarian diet children (6.17%). In the present study, percentage distribution of myopia was found to be higher (4.05%) than the hyperopia (1.24%) and astigmatism (1.14%). Interestingly, in the present study the refractive errors were found significantly higher in Private schools children than Government schools because the children who read in Private schools have higher socioeconomic status; spend more time in home work, watching Television and Computer as compared to government schools children. These near activities of the eyes causes stress on eyes of the children and might be one of the causes of developing myopia.

  6. Frequency of under-corrected refractive errors in elderly Chinese in Beijing.

    PubMed

    Xu, Liang; Li, Jianjun; Cui, Tongtong; Tong, Zhongbiao; Fan, Guizhi; Yang, Hua; Sun, Baochen; Zheng, Yuanyuan; Jonas, Jost B

    2006-07-01

    The aim of the study was to evaluate the prevalence of under-corrected refractive error among elderly Chinese in the Beijing area. The population-based, cross-sectional, cohort study comprised 4,439 subjects out of 5,324 subjects asked to participate (response rate 83.4%) with an age of 40+ years. It was divided into a rural part [1,973 (44.4%) subjects] and an urban part [2,466 (55.6%) subjects]. Habitual and best-corrected visual acuity was measured. Under-corrected refractive error was defined as an improvement in visual acuity of the better eye of at least two lines with best possible refractive correction. The rate of under-corrected refractive error was 19.4% (95% confidence interval, 18.2, 20.6). In a multiple regression analysis, prevalence and size of under-corrected refractive error in the better eye was significantly associated with lower level of education (P<0.001), female gender (P<0.001), and age (P=0.001). Under-correction of refractive error is relatively common among elderly Chinese in the Beijing area when compared with data from other populations.

  7. Relative Proportion Of Different Types Of Refractive Errors In Subjects Seeking Laser Vision Correction

    PubMed Central

    Althomali, Talal A.

    2018-01-01

    Background: Refractive errors are a form of optical defect affecting more than 2.3 billion people worldwide. As refractive errors are a major contributor of mild to moderate vision impairment, assessment of their relative proportion would be helpful in the strategic planning of health programs. Purpose: To determine the pattern of the relative proportion of types of refractive errors among the adult candidates seeking laser assisted refractive correction in a private clinic setting in Saudi Arabia. Methods: The clinical charts of 687 patients (1374 eyes) with mean age 27.6 ± 7.5 years who desired laser vision correction and underwent a pre-LASIK work-up were reviewed retrospectively. Refractive errors were classified as myopia, hyperopia and astigmatism. Manifest refraction spherical equivalent (MRSE) was applied to define refractive errors. Outcome Measures: Distribution percentage of different types of refractive errors; myopia, hyperopia and astigmatism. Results: The mean spherical equivalent for 1374 eyes was -3.11 ± 2.88 D. Of the total 1374 eyes, 91.8% (n = 1262) eyes had myopia, 4.7% (n = 65) eyes had hyperopia and 3.4% (n = 47) had emmetropia with astigmatism. Distribution percentage of astigmatism (cylinder error of ≥ 0.50 D) was 78.5% (1078/1374 eyes); of which % 69.1% (994/1374) had low to moderate astigmatism and 9.4% (129/1374) had high astigmatism. Conclusion and Relevance: Of the adult candidates seeking laser refractive correction in a private setting in Saudi Arabia, myopia represented greatest burden with more than 90% myopic eyes, compared to hyperopia in nearly 5% eyes. Astigmatism was present in more than 78% eyes. PMID:29872484

  8. Peripheral refraction in normal infant rhesus monkeys

    PubMed Central

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  9. [Nature or nurture: effects of parental ametropia on children's refractive errors].

    PubMed

    Landmann, A; Bechrakis, E

    2013-12-01

    The aim of this study was to quantify the degree of association between juvenile refraction errors and parental refraction status. Using a simple questionnaire we conducted a cross-sectional study to determine the prevalence and magnitudes of refractive errors and of parental refraction status in a sample (n=728) of 10- to 18-year-old Austrian grammar school students. Students with myopia or hyperopia were more likely to have ametropic parents and refraction was more myopic in juveniles with one or two parents being ametropic. The prevalence of myopia in children with 2 ametropic parents was 54%, decreasing to 35% in pupils with 1 and to 13% in children with no ametropic parents. The odds ratio for 1 and 2 compared with no ametropic parents was 8.3 and 3.7 for myopia and 1.3 and 1.6 for hyperopia, respectively. Furthermore, the data indicate a stronger influence of the maternal ametropia on children's refractive errors than paternal ametropia. Genetic factors play a significant role in refractive error and may be of dominant influence for school myopia under conditions of low environmental variation.

  10. Uncorrected refractive error and presbyopia among junior high school teachers in Jakarta, Indonesia.

    PubMed

    Ehrlich, Joshua R; Laoh, Alex; Kourgialis, Nick; Prasetyanti, Widya; Zakiyah, Rima; Faillace, Silvana; Friedman, David S

    2013-12-01

    To report on the frequency of observed refractive and accommodative errors among junior high school teachers in Jakarta, Indonesia, who participated in a Helen Keller International screening, refraction and spectacle distribution program. A total of 965 teachers from 19 schools were eligible for screening; those with uncorrected distance visual acuity (VA) ≤ 6/12-3 and teachers ≥ 35 years old with uncorrected end-point print size >Jaeger (J) 6 were referred. Autorefraction and subjective refraction were performed for teachers with confirmed decreased VA. Refractive error was considered present if sphere ≤-0.75 diopters (D), sphere ≥+0.25D or cylinder ≤-0.50 D resulted in ≥ 2 lines of improvement in VA. Presbyopia was considered present if an end-point print size >J6 improved by ≥ 1 optotype with the use of a lens ≥+1.00 D. Overall, 866 teachers were screened (89.7% of those eligible) with complete screening data available for 858 (99.0%), among whom 762 failed screening. Distance refraction data were available for 666 of 762 (87.4%) and near refraction data for 520 of 686 (75.8%) teachers who failed screening. Of those screened, 76.2 ± 9.0% of teachers had refractive and/or accommodative error and 57.1 ± 7.6% had uncorrected refractive and/or accommodative error. Overall and uncorrected distance refractive error affected 44.2 ± 3.7% and 36.0 ± 3.6%, respectively; overall and uncorrected presbyopia affected 66.4 ± 8.1% and 41.0 ± 6.6%, respectively. As defined in this program, refractive and accommodative errors were common among teachers in Jakarta.

  11. Assessing the accuracy and feasibility of a refractive error screening program conducted by school teachers in pre-primary and primary schools in Thailand.

    PubMed

    Teerawattananon, Kanlaya; Myint, Chaw-Yin; Wongkittirux, Kwanjai; Teerawattananon, Yot; Chinkulkitnivat, Bunyong; Orprayoon, Surapong; Kusakul, Suwat; Tengtrisorn, Supaporn; Jenchitr, Watanee

    2014-01-01

    As part of the development of a system for the screening of refractive error in Thai children, this study describes the accuracy and feasibility of establishing a program conducted by teachers. To assess the accuracy and feasibility of screening by teachers. A cross-sectional descriptive and analytical study was conducted in 17 schools in four provinces representing four geographic regions in Thailand. A two-staged cluster sampling was employed to compare the detection rate of refractive error among eligible students between trained teachers and health professionals. Serial focus group discussions were held for teachers and parents in order to understand their attitude towards refractive error screening at schools and the potential success factors and barriers. The detection rate of refractive error screening by teachers among pre-primary school children is relatively low (21%) for mild visual impairment but higher for moderate visual impairment (44%). The detection rate for primary school children is high for both levels of visual impairment (52% for mild and 74% for moderate). The focus group discussions reveal that both teachers and parents would benefit from further education regarding refractive errors and that the vast majority of teachers are willing to conduct a school-based screening program. Refractive error screening by health professionals in pre-primary and primary school children is not currently implemented in Thailand due to resource limitations. However, evidence suggests that a refractive error screening program conducted in schools by teachers in the country is reasonable and feasible because the detection and treatment of refractive error in very young generations is important and the screening program can be implemented and conducted with relatively low costs.

  12. INVOLVEMENT OF MULTIPLE MOLECULAR PATHWAYS IN THE GENETICS OF OCULAR REFRACTION AND MYOPIA.

    PubMed

    Wojciechowski, Robert; Cheng, Ching-Yu

    2018-01-01

    The prevalence of myopia has increased dramatically worldwide within the last three decades. Recent studies have shown that refractive development is influenced by environmental, behavioral, and inherited factors. This review aims to analyze recent progress in the genetics of refractive error and myopia. A comprehensive literature search of PubMed and OMIM was conducted to identify relevant articles in the genetics of refractive error. Genome-wide association and sequencing studies have increased our understanding of the genetics involved in refractive error. These studies have identified interesting candidate genes. All genetic loci discovered to date indicate that refractive development is a heterogeneous process mediated by a number of overlapping biological processes. The exact mechanisms by which these biological networks regulate eye growth are poorly understood. Although several individual genes and/or molecular pathways have been investigated in animal models, a systematic network-based approach in modeling human refractive development is necessary to understand the complex interplay between genes and environment in refractive error. New biomedical technologies and better-designed studies will continue to refine our understanding of the genetics and molecular pathways of refractive error, and may lead to preventative and therapeutic measures to combat the myopia epidemic.

  13. One-kilohertz eye tracker and active intraoperative torsion detection in the NIDEK CXIII and Quest excimer lasers.

    PubMed

    Waring, George O

    2009-10-01

    To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.

  14. Retrospective Analysis of the Post-Operative Changes in Higher-Order Aberrations: A Comparison of the WaveLight EX500 to the VISX S4 Laser in Refractive Surgery.

    PubMed

    Reed, Donovan S; Apsey, Douglas; Steigleman, Walter; Townley, James; Caldwell, Matthew

    2017-11-01

    In an attempt to maximize treatment outcomes, refractive surgery techniques are being directed toward customized ablations to correct not only lower-order aberrations but also higher-order aberrations specific to the individual eye. Measurement of the entirety of ocular aberrations is the most definitive means to establish the true effect of refractive surgery on image quality and visual performance. Whether or not there is a statistically significant difference in induced higher-order corneal aberrations between the VISX Star S4 (Abbott Medical Optics, Santa Ana, California) and the WaveLight EX500 (Alcon, Fort Worth, Texas) lasers was examined. A retrospective analysis was performed to investigate the difference in root-mean-square (RMS) value of the higher-order corneal aberrations postoperatively between two currently available laser platforms, the VISX Star S4 and the WaveLight EX500 lasers. The RMS is a compilation of higher-order corneal aberrations. Data from 240 total eyes of active duty military or Department of Defense beneficiaries who completed photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK) refractive surgery at the Wilford Hall Ambulatory Surgical Center Joint Warfighter Refractive Surgery Center were examined. Using SPSS statistics software (IBM Corp., Armonk, New York), the mean changes in RMS values between the two lasers and refractive surgery procedures were determined. A Student t test was performed to compare the RMS of the higher-order aberrations of the subjects' corneas from the lasers being studied. A regression analysis was performed to adjust for preoperative spherical equivalent. The study and a waiver of informed consent have been approved by the Clinical Research Division of the 59th Medical Wing Institutional Review Board (Protocol Number: 20150093H). The mean change in RMS value for PRK using the VISX laser was 0.00122, with a standard deviation of 0.02583. The mean change in RMS value for PRK using the WaveLight EX500 laser was 0.004323, with a standard deviation of 0.02916. The mean change in RMS value for LASIK using the VISX laser was 0.00841, with a standard deviation of 0.03011. The mean change in RMS value for LASIK using the WaveLight EX500 laser was 0.0174, with a standard deviation of 0.02417. When comparing the two lasers for PRK and LASIK procedures, the p values were 0.431 and 0.295, respectively. The results of this study suggest no statistically significant difference concerning induced higher-order aberrations between the two laser platforms for either LASIK or PRK. Overall, the VISX laser did have consistently lower induced higher-order aberrations postoperatively, but this did not reach statistical significance. It is likely the statistical significance of this study was hindered by the power, given the relatively small sample size. Additional limitations of the study include its design, being a retrospective analysis, and the generalizability of the study, as the Department of Defense population may be significantly different from the typical refractive surgery population in terms of overall health and preoperative refractive error. Further investigation of visual outcomes between the two laser platforms should be investigated before determining superiority in terms of visual image and quality postoperatively. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  15. Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation.

    PubMed

    Savini, Giacomo; Næser, Kristian; Schiano-Lomoriello, Domenico; Ducoli, Pietro

    2017-09-01

    To compare keratometric astigmatism (KA) and different modalities of measuring total corneal astigmatism (TCA) for toric intraocular lens (IOL) calculation and optimize corneal measurements to eliminate the residual refractive astigmatism. G.B. Bietti Foundation IRCCS, Rome, Italy. Prospective case series. Patients who had a toric IOL were enrolled. Preoperatively, a Scheimpflug camera (Pentacam HR) was used to measure TCA through ray tracing. Different combinations of measurements at a 3.0 mm diameter, centered on the pupil or the corneal vertex and performed along a ring or within it, were compared. Keratometric astigmatism was measured using the same Scheimpflug camera and a corneal topographer (Keratron). Astigmatism was analyzed with Næser's polar value method. The optimized preoperative corneal astigmatism was back-calculated from the postoperative refractive astigmatism. The study comprised 62 patients (64 eyes). With both devices, KA produced an overcorrection of with-the-rule (WTR) astigmatism by 0.6 diopter (D) and an undercorrection of against-the-rule (ATR) astigmatism by 0.3 D. The lowest meridional error in refractive astigmatism was achieved by the TCA pupil/zone measurement in WTR eyes (0.27 D overcorrection) and the TCA apex/zone measurement in ATR eyes (0.07 D undercorrection). In the whole sample, no measurement allowed more than 43.75% of eyes to yield an absolute error in astigmatism magnitude lower than 0.5 D. Optimized astigmatism values increased the percentage of eyes with this error up to 57.81%, with no difference compared with the Barrett calculator and the Abulafia-Koch calculator. Compared with KA, TCA improved calculations for toric IOLs; however, optimization of corneal astigmatism measurements led to more accurate results. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    PubMed

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  17. Refractive errors in Mercyland Specialist Hospital, Osogbo, Western Nigeria.

    PubMed

    Adeoti, C O; Egbewale, B E

    2008-06-01

    The study was conducted to determine the magnitude and pattern of refractive errors in order to provide facilities for its management. A prospective study of 3601 eyes of 1824 consective patients was conducted. Information obtained included age, sex, occupation, visual acuity, type and degree of refractive error. The data was analysed using Statistical Package for Social Sciences 11.0 version) Computer Software. Refractive error was found in 1824(53.71%) patients. There were 832(45.61%) males and 992(54.39%) females with a mean age of 35.55. Myopia was the commonest (1412(39.21% eyes). Others include hypermetropia (840(23.33% eyes), astigmatism (785(21.80%) and 820 patients (1640 eyes) had presbyopia. Anisometropia was present in 791(44.51%) of 1777 patients that had bilateral refractive errors. Two thousand two hundred and fifty two eyes has spherical errors. Out of 2252 eyes with spherical errors, 1308 eyes (58.08%) had errors -0.50 to +0.50 dioptres, 567 eyes (25.18%) had errors less than -0.50 dioptres of whom 63 eyes (2.80%) had errors less than -5.00 dioptres while 377 eyes (16.74%) had errors greater than +0.50 dioptres of whom 81 eyes (3.60%) had errors greater than +2.00 dioptres. The highest error was 20.00 dioptres for myopia and 18.00 dioptres for hypermetropia. Refractive error is common in this environment. Adequate provision should be made for its correction bearing in mind the common types and degrees.

  18. [A study of refractive errors in a primary school in Cotonou, Benin].

    PubMed

    Sounouvou, I; Tchabi, S; Doutetien, C; Sonon, F; Yehouessi, L; Bassabi, S K

    2008-10-01

    Determine the epidemiologic aspects and the degree of severity of different refractive errors in primary schoolchildren. A prospective and descriptive study was conducted from 1 December 2005 to 31 March 2006 on schoolchildren ranging from 4 to 16 years of age in a public primary school in Cotonou, Benin. The refraction was evaluated for any visual acuity lower than or equal to 0.7. The study included 1057 schoolchildren. The average age of the study population was 8.5+/-2.6 years with a slight predominance of females (51.8%). The prevalence of refractive error was 10.6% and astigmatism accounted for the most frequent refractive anomaly (91.9%). Myopia and the hyperopia were associated with astigmatism in 29.4% and 16.1% of the cases, respectively. The age bracket from 6 to 11 years accounted for the majority of refractive errors (75.9%), without age and sex being risk factors (p=0.811 and p=0.321, respectively). The average vision of the ametropic eye was 0.61, with a clear predominance of slight refractive errors (89.3%) and particularly of low-level simple astigmatism (45.5%). The relatively low prevalence of refractive error observed does not obviate the need for implementing actions to improve the ocular health of schoolchildren.

  19. Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up.

    PubMed

    Zhang, Jiamei; Wang, Yan; Wu, Wenjing; Xu, Lulu; Li, Xiaojing; Dou, Rui

    2015-01-24

    To evaluate the refractive outcomes for the correction of low to moderate astigmatism up to 1 year following small incision lenticule extraction (SMILE) surgery. This retrospective study enrolled 98 eyes from 98 patients who underwent SMILE surgery for the correction of myopia and astigmatism. Only right eyes were included in this study to avoid the bias of orientation errors. The vector method was used to analyze the outcomes of astigmatism at 1 month, 6 months and 12 months after the procedure, including the double-angle plots, correction index (CI), index of success (IOS), angle of error (AofE) and magnitude of error (MofE). The effectiveness, safety, stability and predictability were also investigated during the 12-month follow-up. The preoperative cylinder ranged from -2.75 D to -0.25 D (average of -0.90±0.68 D), and the mean postoperative cylinder values were -0.24±0.29 D, -0.24±0.29 D, and -0.20±0.27 D at 1 month, 6 months, and 12 months, respectively. The mean astigmatism in vector form was -0.14 D×27.19° at 1 month, -0.13 D×27.29° at 6 months, and -0.10 D×28.63° at 12 months after surgery. The CI was 1.00±0.32 and IOS was 0.29±0.44 at the 12-month follow-up. Significant negative correlations were found between the CI and absolute target induced astigmatism (TIA) value, and positive correlations were found between the IOS and absolute AofE value (P<0.05). The MofE was limited within ±1.00 D at the 12-month follow-up. Fifty-six eyes (57.1%) gained one line in corrected distance visual acuity (CDVA) and five eyes (5.1%) gained two lines. There were no significant differences observed in the refractive outcomes among time points. SMILE surgery was effective and safe in correcting low to moderate astigmatism, and stable refractive outcomes were observed at the long-term follow-up. The undercorrection of astigmatism could possibly be influenced by attempted astigmatism correction preoperatively, the axis rotation during the surgery or wound healing postoperatively. This study suggested that nomograms should be adjusted in correcting astigmatism with SMILE surgery.

  20. Excimer Laser Versus Phakic Intraocular Lenses for Myopia and Astigmatism: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Chen, Haiting; Liu, Yu; Niu, Guangzeng; Ma, Jingxue

    2018-05-01

    Meta-analysis of randomized controlled trials (RCTs) which compared excimer laser refractive surgery and phakic intraocular lenses (PIOLs) for the treatment of myopia and astigmatism. An electronic literature search was performed using the PubMed, EBSCO, CNKI, and Cochrane Library database to identify prospective RCTs which compared excimer laser refractive surgery and PIOL with a follow-up time of at least 12 months. Efficacy, accuracy, safety outcomes, and complications were analyzed by standardized mean difference, risk ratio, and the pooled estimates according to a fixed effect model or random effect model. This review included 5 RCTs with a sum of 405 eyes. The range of myopia was 6.0 to 20.0 D with up to 4.0 D of astigmatism. The PIOL group was more likely to achieve a spherical equivalence within±1.0 D of target refraction at 12 months postoperatively (P=0.009), and was less likely to lose one or more lines of best spectacle corrected visual acuity than the LASER group (P=0.002). On the whole, there is no significant difference in efficacy and complications between the two kinds of surgeries. This meta-analysis indicated that PIOLs were safer and more accurate within 12 months of follow-up compared with excimer laser surgical for refractive errors.

  1. Comparison of self-refraction using a simple device, USee, with manifest refraction in adults.

    PubMed

    Annadanam, Anvesh; Varadaraj, Varshini; Mudie, Lucy I; Liu, Alice; Plum, William G; White, J Kevin; Collins, Megan E; Friedman, David S

    2018-01-01

    The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between -6.00 and +6.00 diopters completed manifest refraction and self-refraction. Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were -0.90 D (±2.53) and -1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00-1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88-28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as "very good" or "excellent" with self-refraction. Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction.

  2. Visual outcomes after Epi-LASIK and PRK for low and moderate myopia.

    PubMed

    Sia, Rose K; Coe, Charles D; Edwards, Jayson D; Ryan, Denise S; Bower, Kraig S

    2012-01-01

    To evaluate visual outcomes following epi-LASIK compared to photorefractive keratectomy (PRK). Of a total 294 patients aged ≥21 years, 145 (290 eyes) underwent epi-LASIK and 149 (298 eyes) underwent PRK for low to moderate myopia or myopic astigmatism. Epi-LASIK was performed with the Amadeus II epikeratome (Abbott Medical Optics) and PRK with the Amoils rotary epithelial brush (Innovative Excimer Solutions). All ablations were performed using the same excimer laser system. Outcome measures included intraoperative complications, corneal reepithelialization, postoperative pain, uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), corneal haze, and quality of vision. Mean preoperative MRSE was -2.97±1.19 diopters (D) for epi-LASIK versus -2.95±1.06 D for PRK. Complete reepithelialization was achieved by postoperative day 4 in 46.9% of epi-LASIK eyes versus 92.4% of PRK eyes, with superior UDVA at postoperative day 1 in the PRK group (P=.002). Using Fisher exact test, a significantly higher percentage of epi-LASIK eyes compared to PRK eyes achieved 20/15 or better at 1 month (25.8% vs 17.8%, P=.031), 3 months (62.3% vs 49.3%, P=.004), 6 months (77.1% vs 57.9%, P<.001), and 12 months (75.9% vs 61.9%, P=.002). A change in MRSE >0.50 D occurred in 8.4% of epi-LASIK eyes within the 3- and 12-month interval versus 17.7% of PRK eyes (P=.04). No differences were noted between the two procedures in CDVA or clinically significant haze. Epi-LASIK showed superior refractive efficacy and stability but required more time for wound healing, resulting in inferior early visual outcomes and a tendency to overcorrect higher refractive errors compared to PRK. Both treatments were safe and comparable in terms of pain and haze formation. Copyright 2012, SLACK Incorporated.

  3. Prevalence of refractive errors in the Slovak population calculated using the Gullstrand schematic eye model.

    PubMed

    Popov, I; Valašková, J; Štefaničková, J; Krásnik, V

    2017-01-01

    A substantial part of the population suffers from some kind of refractive errors. It is envisaged that their prevalence may change with the development of society. The aim of this study is to determine the prevalence of refractive errors using calculations based on the Gullstrand schematic eye model. We used the Gullstrand schematic eye model to calculate refraction retrospectively. Refraction was presented as the need for glasses correction at a vertex distance of 12 mm. The necessary data was obtained using the optical biometer Lenstar LS900. Data which could not be obtained due to the limitations of the device was substituted by theoretical data from the Gullstrand schematic eye model. Only analyses from the right eyes were presented. The data was interpreted using descriptive statistics, Pearson correlation and t-test. The statistical tests were conducted at a level of significance of 5%. Our sample included 1663 patients (665 male, 998 female) within the age range of 19 to 96 years. Average age was 70.8 ± 9.53 years. Average refraction of the eye was 2.73 ± 2.13D (males 2.49 ± 2.34, females 2.90 ± 2.76). The mean absolute error from emmetropia was 3.01 ± 1.58 (males 2.83 ± 2.95, females 3.25 ± 3.35). 89.06% of the sample was hyperopic, 6.61% was myopic and 4.33% emmetropic. We did not find any correlation between refraction and age. Females were more hyperopic than males. We did not find any statistically significant hypermetopic shift of refraction with age. According to our estimation, the calculations of refractive errors using the Gullstrand schematic eye model showed a significant hypermetropic shift of more than +2D. Our results could be used in future for comparing the prevalence of refractive errors using same methods we used.Key words: refractive errors, refraction, Gullstrand schematic eye model, population, emmetropia.

  4. [Refractive errors as causes of visual impairment in children from public schools of the Botucatu region - SP].

    PubMed

    Oliveira, Claudia Akemi Shiratori de; Hisatomi, Kenia Scrocaro; Leite, Cristiano Pinheiro; Schellini, Silvana Artioli; Padovani, Carlos Roberto; Padovani, Carlos Roberto Pereira

    2009-01-01

    To evaluate the refractive errors as cause of visual impairment in school children from the Botucatu region. A sectional study was conducted evaluating preschool and elementary school students, according to gender, refractive error, visual acuity and treatment. Four thousand six hundred and twenty-three (4,623) children were submitted to visual acuity evaluation and 8.1% of them were submitted to complete ocular examination. There were 63.2% hyperopic astigmatism, 15.7% myopic astigmatism, 12.5% astigmatism, 4.9% hyperopia and 3.7% myopia. Corrective lenses were prescribed for 48.7% of the evaluated children. The most frequent refractive error was hyperopic astigmatism and 50% of the children received treatment. The frequency of refractive errors was 3.9% of the studied population.

  5. The patterns of refractive errors among the school children of rural and urban settings in Nepal.

    PubMed

    Pokharel, A; Pokharel, P K; Das, H; Adhikari, S

    2010-01-01

    The uncorrected refractive error is an important cause of childhood blindness and visual impairment. To study the patterns of refractive errors among the urban and rural school going children of Nepal. A total of 440 school children of urban and rural schools within the age range of 7-15 years were selected for this study using multi-stage randomization technique. The overall prevalance of refractive error in school children was 19.8 %. The commonest refractive error among the students was myopia (59.8 %), followed by hypermetropia (31.0 %). The children of age group 12-15 years had the higher prevalence of myopia as compared to the younger counterparts (42.5 % vs 17.2 %). The prevalence of myopia was 15.5 % among the urban students as compared to 8.2 % among the rural ones (RR = 1.89, 95 % CI = 1.1-3.24). The hypermetropia was more common in urban students than in rural ones (6.4 %) vs 5.9 %, RR = 1.08 (95 % CI: 0.52-2.24). The prevalence of refractive error in the school children of Nepal is 19.8 %. The students from urban settings are more likely to have refractive error than their rural counterparts. © Nepal Ophthalmic Society.

  6. Assumption-free estimation of the genetic contribution to refractive error across childhood.

    PubMed

    Guggenheim, Jeremy A; St Pourcain, Beate; McMahon, George; Timpson, Nicholas J; Evans, David M; Williams, Cathy

    2015-01-01

    Studies in relatives have generally yielded high heritability estimates for refractive error: twins 75-90%, families 15-70%. However, because related individuals often share a common environment, these estimates are inflated (via misallocation of unique/common environment variance). We calculated a lower-bound heritability estimate for refractive error free from such bias. Between the ages 7 and 15 years, participants in the Avon Longitudinal Study of Parents and Children (ALSPAC) underwent non-cycloplegic autorefraction at regular research clinics. At each age, an estimate of the variance in refractive error explained by single nucleotide polymorphism (SNP) genetic variants was calculated using genome-wide complex trait analysis (GCTA) using high-density genome-wide SNP genotype information (minimum N at each age=3,404). The variance in refractive error explained by the SNPs ("SNP heritability") was stable over childhood: Across age 7-15 years, SNP heritability averaged 0.28 (SE=0.08, p<0.001). The genetic correlation for refractive error between visits varied from 0.77 to 1.00 (all p<0.001) demonstrating that a common set of SNPs was responsible for the genetic contribution to refractive error across this period of childhood. Simulations suggested lack of cycloplegia during autorefraction led to a small underestimation of SNP heritability (adjusted SNP heritability=0.35; SE=0.09). To put these results in context, the variance in refractive error explained (or predicted) by the time participants spent outdoors was <0.005 and by the time spent reading was <0.01, based on a parental questionnaire completed when the child was aged 8-9 years old. Genetic variation captured by common SNPs explained approximately 35% of the variation in refractive error between unrelated subjects. This value sets an upper limit for predicting refractive error using existing SNP genotyping arrays, although higher-density genotyping in larger samples and inclusion of interaction effects is expected to raise this figure toward twin- and family-based heritability estimates. The same SNPs influenced refractive error across much of childhood. Notwithstanding the strong evidence of association between time outdoors and myopia, and time reading and myopia, less than 1% of the variance in myopia at age 15 was explained by crude measures of these two risk factors, indicating that their effects may be limited, at least when averaged over the whole population.

  7. Refractive errors in 3-6 year-old Chinese children: a very low prevalence of myopia?

    PubMed

    Lan, Weizhong; Zhao, Feng; Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G

    2013-01-01

    To examine the prevalence of refractive errors in children aged 3-6 years in China. Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least -0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5-6 years in most conditions.

  8. Population-based survey of refractive error among school-aged children in rural northern China: the Heilongjiang eye study.

    PubMed

    Li, Zhijian; Xu, Keke; Wu, Shubin; Lv, Jia; Jin, Di; Song, Zhen; Wang, Zhongliang; Liu, Ping

    2014-01-01

    The prevalence of refractive error in the north of China is unknown. The study aimed to estimate the prevalence and associated factors of refractive error in school-aged children in a rural area of northern China. Cross-sectional study. The cluster random sampling method was used to select the sample. A total of 1700 subjects of 5 to 18 years of age were examined. All participants underwent ophthalmic evaluation. Refraction was performed under cycloplegia. Association of refractive errors with age, sex, and education was analysed. The main outcome measure was prevalence rates of refractive error among school-aged children. Of the 1700 responders, 1675 were eligible. The prevalence of uncorrected, presenting, and best-corrected visual acuity of 20/40 or worse in the better eye was 6.3%, 3.0% and 1.2%, respectively. The prevalence of myopia was 5.0% (84/1675, 95% CI, 4.8%-5.4%) and of hyperopia was 1.6% (27/1675, 95% CI, 1.0%-2.2%). Astigmatism was evident in 2.0% of the subjects. Myopia increased with increasing age, whereas hyperopia and astigmatism were associated with younger age. Myopia, hyperopia and astigmatism were more common in females. We also found that prevalence of refractive error were associated with education. Myopia and astigmatism were more common in those with higher degrees of education. This report has provided details of the refractive status in a rural school-aged population. Although the prevalence of refractive errors is lower in the population, the unmet need for spectacle correction remains a significant challenge for refractive eye-care services. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  9. Astigmatism

    MedlinePlus

    ... retina, at the back of your eye. A refractive error If either your cornea or lens is egg ... too close to the television or squinting. Other refractive errors Astigmatism may occur in combination with other refractive ...

  10. Refractive Errors in Patients with Migraine Headache.

    PubMed

    Gunes, Alime; Demirci, Seden; Tok, Levent; Tok, Ozlem; Koyuncuoglu, Hasan; Yurekli, Vedat Ali

    2016-01-01

    To evaluate refractive errors in patients with migraine headache and to compare with healthy subjects. This prospective case-control study includes patients with migraine and age- and sex-matched healthy subjects. Clinical and demographic characteristics of the patients were noted. Detailed ophthalmological examinations were performed containing spherical refractive error, astigmatic refractive error, spherical equivalent (SE), anisometropia, best-corrected visual acuity, intraocular pressure, slit lamp biomicroscopy, fundus examination, axial length, anterior chamber depth, and central corneal thickness. Spectacle use in migraine and control groups was compared. Also, the relationship between refractive components and migraine headache variables was investigated. Seventy-seven migraine patients with mean age of 33.27 ± 8.84 years and 71 healthy subjects with mean age of 31.15 ± 10.45 years were enrolled (p = 0.18). The migraine patients had higher degrees of astigmatic refractive error, SE, and anisometropia when compared with the control subjects (p = 0.01, p = 0.03, p = 0.02, respectively). Migraine patients may have higher degrees of astigmatism, SE, and anisometropia. Therefore, they should have ophthalmological examinations regularly to ensure that their refractive errors are appropriately corrected.

  11. LASIK vs LASEK vs PRK: advantages and indications.

    PubMed

    Ambrósio, Renato; Wilson, Steven

    2003-03-01

    The advent of the excimer laser as an instrument for use in reshaping the corneal stroma was a great step forward in refractive surgery. Laser energy can be delivered on the stromal surface in the photorefractive keratectomy (PRK) procedure or deeper on the corneal stroma by the means of a lamellar surgery in which a flap is created with the microkeratome in the laser in situ keratomileusis (LASIK) procedure. LASIK is currently the dominant procedure in refractive surgery. The main advantage of LASIK over PRK is related to maintaining the central corneal epithelium. This increases comfort during the early post-operative period, allows for rapid visual recovery, and reduces the wound healing response. Reduced wound healing correlates with less regression for high corrections and a lower rate of complications such as significant stromal opacity (haze). PRK, however, remains as an excellent option for mild to moderate corrections, particularly for cases associated with thin corneas, recurrent erosions, or a predisposition for trauma (Martial arts, military, etc.). Recently, a modification of PRK, laser subepithelial keratomileusis (LASEK), was introduced. In the LASEK procedure, an epithelial flap is created and replaced after the ablation. The benefits, if any, of the creation of an epithelial flap compared to traditional PRK are not fully appreciated. Advocates of LASEK suggest that there is less discomfort in the early postoperative period, faster visual recovery, and less haze compared to standard PRK for correction of similar levels of refractive error. Additional long-term clinical studies, along with laboratory research, will be crucial to validate these potential advantages of LASEK procedure.

  12. Refraction test

    MedlinePlus

    ... purpose is to determine whether you have a refractive error (a need for glasses or contact lenses). For ... glasses or contact lenses) is normal, then the refractive error is zero (plano) and your vision should be ...

  13. Outcome of corneal and laser astigmatic axis alignment in photoastigmatic refractive keratectomy.

    PubMed

    Farah, S G; Olafsson, E; Gwynn, D G; Azar, D T; Brightbill, F S

    2000-12-01

    To compare the refractive results of laser astigmatic treatment in eyes in which the astigmatic axes of the eye and laser are aligned by limbal marking at the 6 o'clock position and in eyes that are not marked. University Hospital and Clinics, Madison, Wisconsin, USA. This retrospective study comprised 143 eyes that had photoastigmatic refractive keratectomy with the VISX Star excimer laser. The eyes were divided into marked (G1) and unmarked (G2) groups. Based on the preoperative astigmatism, each group was subdivided into low astigmatism (/=1.25 D). Early postoperative manifest refractions (1.0 to 2.5 months) were analyzed. The Alpins vector analysis method was used to calculate the target induced astigmatism, surgically induced astigmatism, difference vector (DV), magnitude of error (ME), angle of error (AE), and index of success (IS). There was no significant difference between the groups in DV, ME, and IS. When the subgroups were analyzed, the DV and ME were comparable; the IS in the G1 high astigmatism subgroup was significantly better than that in the G2 high astigmatism subgroup (0.22 +/- 0.08 and 0.29 +/- 0.04, respectively; P <.0001). There was comparable scatter of AE values; 30% and 36% in G1 and G2, respectively, had an AE of 0. Similar scatter was observed in the subgroups. Of the eyes that had an AE of 0, 90% and 43% in the high astigmatism subgroups of G1 and G2, respectively (P <.05), had full correction of astigmatism. Limbal marking and subsequent eye and laser astigmatic axis alignment improved the refractive outcome of laser astigmatic treatment of >/=1.25 D. A preliminary report of an ongoing prospective randomized study of eyes that had laser in situ keratomileusis is included.

  14. Screening for refractive error among primary school children in Bayelsa state, Nigeria

    PubMed Central

    Opubiri, Ibeinmo; Pedro-Egbe, Chinyere

    2013-01-01

    Introduction Vision screening study in primary school children has not been done in Bayelsa State. This study aims to screen for refractive error among primary school children in Bayelsa State and use the data to plan for school Eye Health Program. Methods A cross sectional study on screening for refractive error in school children was carried out in Yenagoa Local Government Area of Bayelsa State in June 2009. A multistage sampling technique was used to select the study population (pupils aged between 5-15 years). Visual acuity (VA) for each eye, was assessed outside the classroom at a distance of 6 meters. Those with VA ≤6/9 were presented with a pinhole and the test repeated. Funduscopy was done inside a poorly lit classroom. An improvement of the VA with pinhole was considered refractive error. Data was analyzed with EPI INFO version 6. Results A total of 1,242 school children consisting of 658 females and 584 males were examined.About 97.7% of pupils had normal VA (VA of 6/6) while 56 eyes had VAs ≤ 6/9. Of these 56 eyes, the visual acuity in 49 eyes (87.5%) improved with pinhole. Twenty seven pupils had refractive error, giving a prevalence of 2.2%. Refractive error involved both eyes in 22 pupils (81.5%) and the 8-10 years age range had the highest proportion (40.7%) of cases of refractive error followed by the 9-13 year-old age range (37%). Conclusion The prevalence of refractive error was 2.2% and most eyes (97.7%) had normal vision. PMID:23646210

  15. Refractive eye surgery in treating functional amblyopia in children.

    PubMed

    Levenger, Samuel; Nemet, Pinhas; Hirsh, Ami; Kremer, Israel; Nemet, Arie

    2006-01-01

    While excimer laser refractive surgery is recommended and highly successful for correcting refractive errors in adults, its use in children has not been extensively exercised or studied. We report our experience treating children with amblyopia due to high anisometropia, high astigmatism, high myopia and with associated developmental delay. Review of patient records of our refractive clinic. A retrospective review was made of all 11 children with stable refractive errors who were unsuccessfully treated non-surgically and then underwent corneal refractive surgery and in one case, lenticular surgery. Seven had high myopic anisometropia, 2 had high astigmatism, and two had high myopia--one with Down's Syndrome and one with agenesis of the corpus callosum. The surgical refractive treatment eliminated or reduced the anisometropia, reduced the astigmatic error, improved vision and improved the daily function of the children with developmental delay. There were no complications or untoward results. Refractive surgery is safe and effective in treating children with high myopic anisometropia, high astigmatism, high myopia and developmental delay due to the resulting poor vision. Surgery can improve visual acuity in amblyopia not responding to routine treatment by correcting the refractive error and refractive aberrations.

  16. Prevalence of amblyopia and patterns of refractive error in the amblyopic children of a tertiary eye care center of Nepal.

    PubMed

    Sapkota, K; Pirouzian, A; Matta, N S

    2013-01-01

    Refractive error is a common cause of amblyopia. To determine prevalence of amblyopia and the pattern and the types of refractive error in children with amblyopia in a tertiary eye hospital of Nepal. A retrospective chart review of children diagnosed with amblyopia in the Nepal Eye Hospital (NEH) from July 2006 to June 2011 was conducted. Children of age 13+ or who had any ocular pathology were excluded. Cycloplegic refraction and an ophthalmological examination was performed for all children. The pattern of refractive error and the association between types of refractive error and types of amblyopia were determined. Amblyopia was found in 0.7 % (440) of 62,633 children examined in NEH during this period. All the amblyopic eyes of the subjects had refractive error. Fifty-six percent (248) of the patients were male and the mean age was 7.74 ± 2.97 years. Anisometropia was the most common cause of amblyopia (p less than 0.001). One third (29 %) of the subjects had bilateral amblyopia due to high ametropia. Forty percent of eyes had severe amblyopia with visual acuity of 20/120 or worse. About twothirds (59.2 %) of the eyes had astigmatism. The prevalence of amblyopia in the Nepal Eye Hospital is 0.7%. Anisometropia is the most common cause of amblyopia. Astigmatism is the most common types of refractive error in amblyopic eyes. © NEPjOPH.

  17. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  18. Emmetropisation and the aetiology of refractive errors

    PubMed Central

    Flitcroft, D I

    2014-01-01

    The distribution of human refractive errors displays features that are not commonly seen in other biological variables. Compared with the more typical Gaussian distribution, adult refraction within a population typically has a negative skew and increased kurtosis (ie is leptokurtotic). This distribution arises from two apparently conflicting tendencies, first, the existence of a mechanism to control eye growth during infancy so as to bring refraction towards emmetropia/low hyperopia (ie emmetropisation) and second, the tendency of many human populations to develop myopia during later childhood and into adulthood. The distribution of refraction therefore changes significantly with age. Analysis of the processes involved in shaping refractive development allows for the creation of a life course model of refractive development. Monte Carlo simulations based on such a model can recreate the variation of refractive distributions seen from birth to adulthood and the impact of increasing myopia prevalence on refractive error distributions in Asia. PMID:24406411

  19. Comparison of self-refraction using a simple device, USee, with manifest refraction in adults

    PubMed Central

    Annadanam, Anvesh; Mudie, Lucy I.; Liu, Alice; Plum, William G.; White, J. Kevin; Collins, Megan E.; Friedman, David S.

    2018-01-01

    Background The USee device is a new self-refraction tool that allows users to determine their own refractive error. We evaluated the ease of use of USee in adults, and compared the refractive error correction achieved with USee to clinical manifest refraction. Methods Sixty adults with uncorrected visual acuity <20/30 and spherical equivalent between –6.00 and +6.00 diopters completed manifest refraction and self-refraction. Results Subjects had a mean (±SD) age of 53.1 (±18.6) years, and 27 (45.0%) were male. Mean (±SD) spherical equivalent measured by manifest refraction and self-refraction were –0.90 D (±2.53) and –1.22 diopters (±2.42), respectively (p = 0.001). The proportion of subjects correctable to ≥20/30 in the better eye was higher for manifest refraction (96.7%) than self-refraction (83.3%, p = 0.005). Failure to achieve visual acuity ≥20/30 with self-refraction in right eyes was associated with increasing age (per year, OR: 1.05; 95% CI: 1.00–1.10) and higher cylindrical power (per diopter, OR: 7.26; 95% CI: 1.88–28.1). Subjectively, 95% of participants thought USee was easy to use, 85% thought self-refraction correction was better than being uncorrected, 57% thought vision with self-refraction correction was similar to their current corrective lenses, and 53% rated their vision as “very good” or “excellent” with self-refraction. Conclusion Self-refraction provides acceptable refractive error correction in the majority of adults. Programs targeting resource-poor settings could potentially use USee to provide easy on-site refractive error correction. PMID:29390026

  20. Refraction error correction for deformation measurement by digital image correlation at elevated temperature

    NASA Astrophysics Data System (ADS)

    Su, Yunquan; Yao, Xuefeng; Wang, Shen; Ma, Yinji

    2017-03-01

    An effective correction model is proposed to eliminate the refraction error effect caused by an optical window of a furnace in digital image correlation (DIC) deformation measurement under high-temperature environment. First, a theoretical correction model with the corresponding error correction factor is established to eliminate the refraction error induced by double-deck optical glass in DIC deformation measurement. Second, a high-temperature DIC experiment using a chromium-nickel austenite stainless steel specimen is performed to verify the effectiveness of the correction model by the correlation calculation results under two different conditions (with and without the optical glass). Finally, both the full-field and the divisional displacement results with refraction influence are corrected by the theoretical model and then compared to the displacement results extracted from the images without refraction influence. The experimental results demonstrate that the proposed theoretical correction model can effectively improve the measurement accuracy of DIC method by decreasing the refraction errors from measured full-field displacements under high-temperature environment.

  1. Intertester agreement in refractive error measurements.

    PubMed

    Huang, Jiayan; Maguire, Maureen G; Ciner, Elise; Kulp, Marjean T; Quinn, Graham E; Orel-Bixler, Deborah; Cyert, Lynn A; Moore, Bruce; Ying, Gui-Shuang

    2013-10-01

    To determine the intertester agreement of refractive error measurements between lay and nurse screeners using the Retinomax Autorefractor and the SureSight Vision Screener. Trained lay and nurse screeners measured refractive error in 1452 preschoolers (3 to 5 years old) using the Retinomax and the SureSight in a random order for screeners and instruments. Intertester agreement between lay and nurse screeners was assessed for sphere, cylinder, and spherical equivalent (SE) using the mean difference and the 95% limits of agreement. The mean intertester difference (lay minus nurse) was compared between groups defined based on the child's age, cycloplegic refractive error, and the reading's confidence number using analysis of variance. The limits of agreement were compared between groups using the Brown-Forsythe test. Intereye correlation was accounted for in all analyses. The mean intertester differences (95% limits of agreement) were -0.04 (-1.63, 1.54) diopter (D) sphere, 0.00 (-0.52, 0.51) D cylinder, and -0.04 (1.65, 1.56) D SE for the Retinomax and 0.05 (-1.48, 1.58) D sphere, 0.01 (-0.58, 0.60) D cylinder, and 0.06 (-1.45, 1.57) D SE for the SureSight. For either instrument, the mean intertester differences in sphere and SE did not differ by the child's age, cycloplegic refractive error, or the reading's confidence number. However, for both instruments, the limits of agreement were wider when eyes had significant refractive error or the reading's confidence number was below the manufacturer's recommended value. Among Head Start preschool children, trained lay and nurse screeners agree well in measuring refractive error using the Retinomax or the SureSight. Both instruments had similar intertester agreement in refractive error measurements independent of the child's age. Significant refractive error and a reading with low confidence number were associated with worse intertester agreement.

  2. Refractive errors in children and adolescents in Bucaramanga (Colombia).

    PubMed

    Galvis, Virgilio; Tello, Alejandro; Otero, Johanna; Serrano, Andrés A; Gómez, Luz María; Castellanos, Yuly

    2017-01-01

    The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia). This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D). Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.

  3. Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial.

    PubMed

    Ang, Marcus; Tan, Donald; Mehta, Jodhbir S

    2012-05-31

    Small incision lenticule extraction or SMILE is a novel form of 'flapless' corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. This novel trial will provide information on whether SMILE has comparable, if not superior, refractive outcomes compared to the established LASIK for myopia, thus providing evidence for translation into clinical practice. Clinicaltrials.gov NCT01216475.

  4. Effect of single vision soft contact lenses on peripheral refraction.

    PubMed

    Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen

    2012-07-01

    To investigate changes in peripheral refraction with under-, full, and over-correction of central refraction with commercially available single vision soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere SCLs to under-correct (+0.75 DS), fully correct, and over-correct (-0.75 DS) their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with different levels of SCL central refractive error correction. The uncorrected refractive error was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared to center at 30 and 35° in the temporal visual field (VF) in low myopes and at 30 and 35° in the temporal VF and 10, 30, and 35° in the nasal VF in moderate myopes. All levels of SCL correction caused a hyperopic shift in refraction at all locations in the horizontal VF. The smallest hyperopic shift was demonstrated with under-correction followed by full correction and then by over-correction of central refractive error. An increase in relative peripheral hyperopia was measured with full correction SCLs compared with no correction in both low and moderate myopes. However, no difference in relative peripheral refraction profiles were found between under-, full, and over-correction. Under-, full, and over-correction of central refractive error with single vision SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. All levels of SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction, to experience absolute hyperopic defocus. This peripheral hyperopia may be a possible cause of myopia progression reported with different types and levels of myopia correction.

  5. The prevalence of uncorrected refractive errors in underserved rural areas.

    PubMed

    Hashemi, Hassan; Abbastabar, Hedayat; Yekta, Abbasali; Heydarian, Samira; Khabazkhoob, Mehdi

    2017-12-01

    To determine the prevalence of uncorrected refractive errors, need for spectacles, and the determinants of unmet need in underserved rural areas of Iran. In a cross-sectional study, multistage cluster sampling was done in 2 underserved rural areas of Iran. Then, all subjects underwent vision testing and ophthalmic examinations including the measurement of uncorrected visual acuity (UCVA), best corrected visual acuity, visual acuity with current spectacles, auto-refraction, retinoscopy, and subjective refraction. Need for spectacles was defined as UCVA worse than 20/40 in the better eye that could be corrected to better than 20/40 with suitable spectacles. Of the 3851 selected individuals, 3314 participated in the study. Among participants, 18.94% [95% confidence intervals (CI): 13.48-24.39] needed spectacles and 11.23% (95% CI: 7.57-14.89) had an unmet need. The prevalence of need for spectacles was 46.8% and 23.8% in myopic and hyperopic participants, respectively. The prevalence of unmet need was 27% in myopic, 15.8% in hyperopic, and 25.46% in astigmatic participants. Multiple logistic regression showed that education and type of refractive errors were associated with uncorrected refractive errors; the odds of uncorrected refractive errors were highest in illiterate participants, and the odds of unmet need were 12.13, 5.1, and 4.92 times higher in myopic, hyperopic and astigmatic participants as compared with emmetropic individuals. The prevalence of uncorrected refractive errors was rather high in our study. Since rural areas have less access to health care facilities, special attention to the correction of refractive errors in these areas, especially with inexpensive methods like spectacles, can prevent a major proportion of visual impairment.

  6. Refraction-compensated motion tracking of unrestrained small animals in positron emission tomography.

    PubMed

    Kyme, Andre; Meikle, Steven; Baldock, Clive; Fulton, Roger

    2012-08-01

    Motion-compensated radiotracer imaging of fully conscious rodents represents an important paradigm shift for preclinical investigations. In such studies, if motion tracking is performed through a transparent enclosure containing the awake animal, light refraction at the interface will introduce errors in stereo pose estimation. We have performed a thorough investigation of how this impacts the accuracy of pose estimates and the resulting motion correction, and developed an efficient method to predict and correct for refraction-based error. The refraction model underlying this study was validated using a state-of-the-art motion tracking system. Refraction-based error was shown to be dependent on tracking marker size, working distance, and interface thickness and tilt. Correcting for refraction error improved the spatial resolution and quantitative accuracy of motion-corrected positron emission tomography images. Since the methods are general, they may also be useful in other contexts where data are corrupted by refraction effects. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  7. Refractive errors.

    PubMed

    Schiefer, Ulrich; Kraus, Christina; Baumbach, Peter; Ungewiß, Judith; Michels, Ralf

    2016-10-14

    All over the world, refractive errors are among the most frequently occuring treatable distur - bances of visual function. Ametropias have a prevalence of nearly 70% among adults in Germany and are thus of great epidemiologic and socio-economic relevance. In the light of their own clinical experience, the authors review pertinent articles retrieved by a selective literature search employing the terms "ametropia, "anisometropia," "refraction," "visual acuity," and epidemiology." In 2011, only 31% of persons over age 16 in Germany did not use any kind of visual aid; 63.4% wore eyeglasses and 5.3% wore contact lenses. Refractive errors were the most common reason for consulting an ophthalmologist, accounting for 21.1% of all outpatient visits. A pinhole aperture (stenopeic slit) is a suitable instrument for the basic diagnostic evaluation of impaired visual function due to optical factors. Spherical refractive errors (myopia and hyperopia), cylindrical refractive errors (astigmatism), unequal refractive errors in the two eyes (anisometropia), and the typical optical disturbance of old age (presbyopia) cause specific functional limitations and can be detected by a physician who does not need to be an ophthalmologist. Simple functional tests can be used in everyday clinical practice to determine quickly, easily, and safely whether the patient is suffering from a benign and easily correctable type of visual impairment, or whether there are other, more serious underlying causes.

  8. Mechanisms of Optical Regression Following Corneal Laser Refractive Surgery: Epithelial and Stromal Responses

    PubMed Central

    MOSHIRFAR, Majid; DESAUTELS, Jordan D.; WALKER, Brian D.; MURRI, Michael S.; BIRDSONG, Orry C.; HOOPES, Phillip C. Sr

    2018-01-01

    Laser vision correction is a safe and effective method of reducing spectacle dependence. Photorefractive Keratectomy (PRK), Laser In Situ Keratomileusis (LASIK), and Small-Incision Lenticule Extraction (SMILE) can accurately correct myopia, hyperopia, and astigmatism. Although these procedures are nearing optimization in terms of their ability to produce a desired refractive target, the long term cellular responses of the cornea to these procedures can cause patients to regress from the their ideal postoperative refraction. In many cases, refractive regression requires follow up enhancement surgeries, presenting additional risks to patients. Although some risk factors underlying refractive regression have been identified, the exact mechanisms have not been elucidated. It is clear that cellular proliferation events are important mediators of optical regression. This review focused specifically on cellular changes to the corneal epithelium and stroma, which may influence postoperative visual regression following LASIK, PRK, and SMILE procedures. PMID:29644238

  9. Multiple regression analysis in nomogram development for myopic wavefront laser in situ keratomileusis: Improving astigmatic outcomes.

    PubMed

    Allan, Bruce D; Hassan, Hala; Ieong, Alvin

    2015-05-01

    To describe and evaluate a new multiple regression-derived nomogram for myopic wavefront laser in situ keratomileusis (LASIK). Moorfields Eye Hospital, London, United Kingdom. Prospective comparative case series. Multiple regression modeling was used to derive a simplified formula for adjusting attempted spherical correction in myopic LASIK. An adaptation of Thibos' power vector method was then applied to derive adjustments to attempted cylindrical correction in eyes with 1.0 diopter (D) or more of preoperative cylinder. These elements were combined in a new nomogram (nomogram II). The 3-month refractive results for myopic wavefront LASIK (spherical equivalent ≤11.0 D; cylinder ≤4.5 D) were compared between 299 consecutive eyes treated using the earlier nomogram (nomogram I) in 2009 and 2010 and 414 eyes treated using nomogram II in 2011 and 2012. There was no significant difference in treatment accuracy (variance in the postoperative manifest refraction spherical equivalent error) between nomogram I and nomogram II (P = .73, Bartlett test). Fewer patients treated with nomogram II had more than 0.5 D of residual postoperative astigmatism (P = .0001, Fisher exact test). There was no significant coupling between adjustments to the attempted cylinder and the achieved sphere (P = .18, t test). Discarding marginal influences from a multiple regression-derived nomogram for myopic wavefront LASIK had no clinically significant effect on treatment accuracy. Thibos' power vector method can be used to guide adjustments to the treatment cylinder alongside nomograms designed to optimize postoperative spherical equivalent results in myopic LASIK. mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Refractive Outcomes After Femtosecond Laser-Assisted Cataract Surgery in Eyes With Anterior Chamber Phakic Intraocular Lenses.

    PubMed

    Steinwender, Gernot; Shajari, Mehdi; Kohnen, Thomas

    2018-05-01

    To report the efficacy, predictability, and safety of femtosecond laser-assisted cataract surgery (FLACS) in eyes with anterior chamber phakic intraocular lenses (IOLs). This retrospective case series included eyes with previous implantation of an angle-supported and an iris-fixated phakic IOL for the correction of myopia that underwent a combined procedure of phakic IOL ex-plantation and FLACS with in-the-bag implantation of a posterior chamber IOL. Postoperative corrected distance visual acuity (CDVA), predictability of refractive outcome, and occurrence of intraoperative and postoperative complications were analyzed. Ten eyes of 7 patients with significant cataract were included: 5 eyes with an angle-supported foldable hydrophobic phakic IOL, 4 eyes with an angle-supported polymethylmethacrylate (PMMA) phakic IOL, and 1 eye with an iris-fixated PMMA phakic IOL. Mean follow-up after FLACS was 8.4 ± 5.8 months. Mean interval between phakic IOL implantation and FLACS was 11.9 ± 4.0 years. After the combined procedure of phakic IOL explantation and FLACS, mean manifest refractive spherical equivalent (MRSE) was -0.11 ± 0.49 diopters (D) and MRSE was within ± 0.75 D of target refraction in all eyes. Four eyes received a toric posterior chamber IOL after phacoemulsification. Mean preoperative CDVA of 0.40 ± 0.23 logMAR improved significantly to 0.22 ± 0.11 logMAR postoperatively (P = .027). No intraoperative or postoperative complications occurred. The results in this series showed that FLACS in eyes with previous implantation of both rigid and foldable anterior chamber phakic IOLs offers good refractive outcomes with a high level of predictability and safety. [J Refract Surg. 2018;34(5):338-342.]. Copyright 2018, SLACK Incorporated.

  11. Prevalence of amblyopia and refractive errors in an unscreened population of children.

    PubMed

    Polling, Jan-Roelof; Loudon, Sjoukje E; Klaver, Caroline C W

    2012-11-01

    To describe the frequency of refractive errors and amblyopia in unscreened children aged 2 months to 12 years from a rural town in Poland. Five hundred ninety-one children were identified by medical records and examined in a standardized manner.Visual acuity was measured using LogMAR charts; refractive error was determined using retinoscopy or autorefraction after cycloplegia. Myopia was defined as spherical equivalent (SE) ≤ -0.50 D, emmetropia as SE between -0.5 D and+0.5 D, mild hyperopia as SE between +0.5 D and +2.0 D, and high hyperopia as SE Q+2.0 D. Amblyopia was classified as best-corrected visual acuity ≥0.3 (≤ 20/40) LogMAR, in combination with a 2 LogMAR line difference between the two eyes and the presence of an amblyogenic factor. Refractive errors ranged from 84.2% in children aged up to 2 years to 75.5% in those aged 10 to 12 years.Refractive error showed a myopic shift with age; myopia prevalence increased from 2.2% in those aged 6 to 7 years to 6.3% in those aged 10 to 12 years. Of the examined children, 77 (16.3%) had refractive errors, with visual loss; of these,60 (78%) did not use corrections. The prevalence of amblyopia was 3.1%, and refractive error attributed to the amblyopiain 9 of 13 (69%) children. Refractive errors are common in Caucasian children and often remain undiagnosed. The prevalence of amblyopia was three times higher in this unscreened population compared with screened populations. Greater awarenessof these common treatable visual conditions in children is warranted.

  12. Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality

    PubMed Central

    Zaldivar, R.; Aiello, F.; Madrid-Costa, D.

    2017-01-01

    Keratoconus provides a decrease of quality of life to the patients who suffer from it. The treatment used as well as the method to correct the refractive error of these patients may influence on the impact of the disease on their quality of life. The purpose of this review is to describe the evidence about the conservative surgical treatment for keratoconus aiming to therapeutic and refractive effect. The visual rehabilitation for keratoconic corneas requires addressing three concerns: halting the ectatic process, improving corneal shape, and minimizing the residual refractive error. Cross-linking can halt the disease progression, intrastromal corneal ring segments can improve the corneal shape and hence the visual quality and reduce the refractive error, PRK can correct mild-moderate refractive error, and intraocular lenses can correct from low to high refractive error associated with keratoconus. Any of these surgical options can be performed alone or combined with the other techniques depending on what the case requires. Although it could be considered that the surgical option for the refracto-therapeutic treatment of the keratoconus is a reality, controlled, randomized studies with larger cohorts and longer follow-up periods are needed to determine which refractive procedure and/or sequence are most suitable for each case. PMID:29403662

  13. Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).

    PubMed

    Wolfram, Christian; Höhn, René; Kottler, Ulrike; Wild, Philipp; Blettner, Maria; Bühren, Jens; Pfeiffer, Norbert; Mirshahi, Alireza

    2014-07-01

    To study the distribution of refractive errors among adults of European descent. Population-based eye study in Germany with 15010 participants aged 35-74 years. The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia <-0.5 dioptres (D), hyperopia >+0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. 13959 subjects were eligible. Refractive errors ranged from -21.5 to +13.88 D. Myopia was present in 35.1% of this study sample, hyperopia in 31.8%, astigmatism in 32.3% and anisometropia in 13.5%. The prevalence of myopia decreased, while the prevalence of hyperopia, astigmatism and anisometropia increased with age. 3.5% of the study sample had no refractive correction for their ametropia. Refractive errors affect the majority of the population. The Gutenberg Health Study sample contains more myopes than other study cohorts in adult populations. Our findings do not support the hypothesis of a generally lower prevalence of myopia among adults in Europe as compared with East Asia.

  14. Prevalence of refraction errors and color blindness in heavy vehicle drivers.

    PubMed

    Erdoğan, Haydar; Ozdemir, Levent; Arslan, Seher; Cetin, Ilhan; Ozeç, Ayşe Vural; Cetinkaya, Selma; Sümer, Haldun

    2011-01-01

    To investigate the frequency of eye disorders in heavy vehicle drivers. A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security.

  15. Prevalence of refraction errors and color blindness in heavy vehicle drivers

    PubMed Central

    Erdoğan, Haydar; Özdemir, Levent; Arslan, Seher; Çetin, Ilhan; Özeç, Ayşe Vural; Çetinkaya, Selma; Sümer, Haldun

    2011-01-01

    AIM To investigate the frequency of eye disorders in heavy vehicle drivers. METHODS A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. RESULTS According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. CONCLUSION A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security. PMID:22553671

  16. [New possibilities screening of refractive errors among children].

    PubMed

    Ondrejková, M; Kyselová, P

    2013-06-01

    To establish early detection of refractive errors among children in Slovakia. Different screening methods have been evaluated and compared in this work. we have been working on a prospective study. Pre-school children in kindergardens in Central Slovakia were checked up between years 2009-2011. Effectiveness of various screening methods was compared within 2 groups, using test-type and Plusoptix Vision Screener. Parentęs of children positive to refractive errors were recommended to consult a paediatrician ophthalmologist. 3982 children were examined. As a result, 13-14.1% of children who have not been examinated by the specialist, were positive. 53.3% of them went to see the doctor afterwards. establishment of early refractive errors screening is an important method how to prevent strabismus and amblyopia. It is very important to improve parentęs knowledge about the risk of refractive errors and also to improve screening methods with collaboration with kindergarten teachers.

  17. Atmospheric microwave refractivity and refraction

    NASA Technical Reports Server (NTRS)

    Yu, E.; Hodge, D. B.

    1980-01-01

    The atmospheric refractivity can be expressed as a function of temperature, pressure, water vapor content, and operating frequency. Based on twenty-year meteorological data, statistics of the atmospheric refractivity were obtained. These statistics were used to estimate the variation of dispersion, attenuation, and refraction effects on microwave and millimeter wave signals propagating along atmospheric paths. Bending angle, elevation angle error, and range error were also developed for an exponentially tapered, spherical atmosphere.

  18. Prevalence of refractive error in Europe: the European Eye Epidemiology (E(3)) Consortium.

    PubMed

    Williams, Katie M; Verhoeven, Virginie J M; Cumberland, Phillippa; Bertelsen, Geir; Wolfram, Christian; Buitendijk, Gabriëlle H S; Hofman, Albert; van Duijn, Cornelia M; Vingerling, Johannes R; Kuijpers, Robert W A M; Höhn, René; Mirshahi, Alireza; Khawaja, Anthony P; Luben, Robert N; Erke, Maja Gran; von Hanno, Therese; Mahroo, Omar; Hogg, Ruth; Gieger, Christian; Cougnard-Grégoire, Audrey; Anastasopoulos, Eleftherios; Bron, Alain; Dartigues, Jean-François; Korobelnik, Jean-François; Creuzot-Garcher, Catherine; Topouzis, Fotis; Delcourt, Cécile; Rahi, Jugnoo; Meitinger, Thomas; Fletcher, Astrid; Foster, Paul J; Pfeiffer, Norbert; Klaver, Caroline C W; Hammond, Christopher J

    2015-04-01

    To estimate the prevalence of refractive error in adults across Europe. Refractive data (mean spherical equivalent) collected between 1990 and 2013 from fifteen population-based cohort and cross-sectional studies of the European Eye Epidemiology (E(3)) Consortium were combined in a random effects meta-analysis stratified by 5-year age intervals and gender. Participants were excluded if they were identified as having had cataract surgery, retinal detachment, refractive surgery or other factors that might influence refraction. Estimates of refractive error prevalence were obtained including the following classifications: myopia ≤-0.75 diopters (D), high myopia ≤-6D, hyperopia ≥1D and astigmatism ≥1D. Meta-analysis of refractive error was performed for 61,946 individuals from fifteen studies with median age ranging from 44 to 81 and minimal ethnic variation (98 % European ancestry). The age-standardised prevalences (using the 2010 European Standard Population, limited to those ≥25 and <90 years old) were: myopia 30.6 % [95 % confidence interval (CI) 30.4-30.9], high myopia 2.7 % (95 % CI 2.69-2.73), hyperopia 25.2 % (95 % CI 25.0-25.4) and astigmatism 23.9 % (95 % CI 23.7-24.1). Age-specific estimates revealed a high prevalence of myopia in younger participants [47.2 % (CI 41.8-52.5) in 25-29 years-olds]. Refractive error affects just over a half of European adults. The greatest burden of refractive error is due to myopia, with high prevalence rates in young adults. Using the 2010 European population estimates, we estimate there are 227.2 million people with myopia across Europe.

  19. Posterior corneal astigmatism in refractive lens exchange surgery.

    PubMed

    Rydström, Elin; Westin, Oscar; Koskela, Timo; Behndig, Anders

    2016-05-01

    To assess the anterior, posterior and total corneal spherical and astigmatic powers in patients undergoing refractive lens exchange (RLE) surgery. In 402 consecutive patients planned for RLE at Koskelas Eye Clinic, Luleå, Sweden, right eye data from pre- and postoperative subjective refraction, preoperative IOLMaster(®) biometry and Pentacam HR(®) measurements were collected. Postoperative Pentacam HR(®) data were collected for 54 of the patients. The spherical and astigmatic powers of the anterior and posterior corneal surfaces and for the total cornea were assessed and compared, and surgically, induced astigmatism was calculated using vector analysis. The spherical power of the anterior corneal surface was 48.18 ± 1.69D with an astigmatic power of 0.83 ± 0.54D. The corresponding values for the posterior surface were -6.05 ± 2,52D and 0.26 ± 0.15D, respectively. The total corneal spherical power calculated with ray tracing was 42.47 ± 2.89D with a 0.72 ± 0.48D astigmatic power, and the corresponding figures obtained by estimating the posterior corneal surface were 43.25 ± 1.51D (p < 0.001) with a 0.75 ± 0.49D astigmatic power (p = 0.003). In eyes with anterior astigmatism with-the-rule, the total corneal astigmatism is overestimated if the posterior corneal surface is estimated; in eyes, with against-the-rule astigmatism it is underestimated. Had the posterior corneal surface been measured in this material, 14.7% of the patients would have received a spheric instead of a toric IOL, or vice versa. Estimating the posterior corneal surface in RLE patients leads to systematic measurement errors that can be reduced by measuring the posterior surface. Such an approach can potentially increase the refractive outcome accuracy in RLE surgery. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Refractive errors among patients attending the ophthalmology department of a medical college in North-East India

    PubMed Central

    Natung, Tanie; Taye, Trishna; Lyngdoh, Laura Amanda; Dkhar, Begonia; Hajong, Ranendra

    2017-01-01

    Purpose: To determine the magnitude and pattern of refractive errors among patients attending the ophthalmology department of a new medical college in North-East India. Materials and Methods: A prospective study of the new patients (age ≥5 years), who were phakic and whose unaided visual acuities were worse than 20/20 but improved with pinhole, was done. Complete ophthalmic examination and refraction with appropriate cycloplegia for age were done for the 4582 eligible patients. Spherical equivalents (SE) of refractive errors of the right eyes were used for analysis. Results: Of the 4582 eligible patients, 2546 patients had refractive errors (55.56%). The proportion of emmetropia (SE − 0.50–+0.50 diopter sphere [DS]), myopia (SE <−0.50 DS), high myopia (SE >−5.0 DS), and hypermetropia (>+0.50 DS for adults and >+2.0 DS for children) were 53.1%, 27.4%, 2.6%, and 16.9%, respectively. The proportion of hyperopia increased till 59 years and then decreased with age (P = 0.000). The proportion of myopia and high myopia decreased significantly with age after 39 years (P = 0.000 and P = 0.004, respectively). Of the 1510 patients with astigmatism, 17% had with-the-rule (WTR), 23.4% had against-the-rule (ATR), and 19% had oblique astigmatisms. The proportion of WTR and ATR astigmatisms significantly decreased (P = 0.000) and increased (P = 0.000) with age, respectively. Conclusions: This study has provided the magnitude and pattern of refractive errors in the study population. It will serve as the initial step for conducting community-based studies on the prevalence of refractive errors in this part of the country since such data are lacking from this region. Moreover, this study will help the primary care physicians to have an overview of the magnitude and pattern of refractive errors presenting to a health-care center as refractive error is an established and significant public health problem worldwide. PMID:29417005

  1. Refractive errors among patients attending the ophthalmology department of a medical college in North-East India.

    PubMed

    Natung, Tanie; Taye, Trishna; Lyngdoh, Laura Amanda; Dkhar, Begonia; Hajong, Ranendra

    2017-01-01

    To determine the magnitude and pattern of refractive errors among patients attending the ophthalmology department of a new medical college in North-East India. A prospective study of the new patients (age ≥5 years), who were phakic and whose unaided visual acuities were worse than 20/20 but improved with pinhole, was done. Complete ophthalmic examination and refraction with appropriate cycloplegia for age were done for the 4582 eligible patients. Spherical equivalents (SE) of refractive errors of the right eyes were used for analysis. Of the 4582 eligible patients, 2546 patients had refractive errors (55.56%). The proportion of emmetropia (SE - 0.50-+0.50 diopter sphere [DS]), myopia (SE <-0.50 DS), high myopia (SE >-5.0 DS), and hypermetropia (>+0.50 DS for adults and >+2.0 DS for children) were 53.1%, 27.4%, 2.6%, and 16.9%, respectively. The proportion of hyperopia increased till 59 years and then decreased with age ( P = 0.000). The proportion of myopia and high myopia decreased significantly with age after 39 years ( P = 0.000 and P = 0.004, respectively). Of the 1510 patients with astigmatism, 17% had with-the-rule (WTR), 23.4% had against-the-rule (ATR), and 19% had oblique astigmatisms. The proportion of WTR and ATR astigmatisms significantly decreased ( P = 0.000) and increased ( P = 0.000) with age, respectively. This study has provided the magnitude and pattern of refractive errors in the study population. It will serve as the initial step for conducting community-based studies on the prevalence of refractive errors in this part of the country since such data are lacking from this region. Moreover, this study will help the primary care physicians to have an overview of the magnitude and pattern of refractive errors presenting to a health-care center as refractive error is an established and significant public health problem worldwide.

  2. Refractive Errors in 3–6 Year-Old Chinese Children: A Very Low Prevalence of Myopia?

    PubMed Central

    Lin, Lixia; Li, Zhen; Zeng, Junwen; Yang, Zhikuan; Morgan, Ian G.

    2013-01-01

    Purpose To examine the prevalence of refractive errors in children aged 3–6 years in China. Methods Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex) was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least −0.50 D in the worse eye), hyperopia (at least +2.00 D in the worse eye) and astigmatism (at least 1.50 D in the worse eye). Different definitions, as specified in the text, were also used to facilitate comparison with other studies. Results The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. Conclusions Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5–6 yearsin most conditions. PMID:24205064

  3. Profile of refractive errors in European Caucasian children with Autistic Spectrum Disorder; increased prevalence and magnitude of astigmatism.

    PubMed

    Anketell, Pamela M; Saunders, Kathryn J; Gallagher, Stephen; Bailey, Clare; Little, Julie-Anne

    2016-07-01

    Autistic Spectrum Disorder (ASD) is a common neurodevelopmental disorder characterised by impairment of communication, social interaction and repetitive behaviours. Only a small number of studies have investigated fundamental clinical measures of vision including refractive error. The aim of this study was to describe the refractive profile of a population of children with ASD compared to typically developing (TD) children. Refractive error was assessed using the Shin-Nippon NVision-K 5001 open-field autorefractor following the instillation of cyclopentolate hydrochloride 1% eye drops. A total of 128 participants with ASD (mean age 10.9 ± 3.3 years) and 206 typically developing participants (11.5 ± 3.1 years) were recruited. There was no significant difference in median refractive error, either by spherical equivalent or most ametropic meridian between the ASD and TD groups (Spherical equivalent, Mann-Whitney U307 = 1.15, p = 0.25; Most Ametropic Meridian, U305 = 0.52, p = 0.60). Median refractive astigmatism was -0.50DC (range 0.00 to -3.50DC) for the ASD group and -0.50DC (Range 0.00 to -2.25DC) for the TD group. Magnitude and prevalence of refractive astigmatism (defined as astigmatism ≥1.00DC) was significantly greater in the ASD group compared to the typically developing group (ASD 26%, TD 8%, magnitude U305 = 3.86, p = 0.0001; prevalence (χ12=17.71 , p < 0.0001). This is the first study to describe the refractive profile of a population of European Caucasian children with ASD compared to a TD population of children. Unlike other neurodevelopmental conditions, there was no increased prevalence of spherical refractive errors in ASD but astigmatic errors were significantly greater in magnitude and prevalence. This highlights the need to examine refractive errors in this population. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  4. Retrospective analysis of refractive errors in children with vision impairment.

    PubMed

    Du, Jojo W; Schmid, Katrina L; Bevan, Jennifer D; Frater, Karen M; Ollett, Rhondelle; Hein, Bronwyn

    2005-09-01

    Emmetropization is the reduction in neonatal refractive errors that occurs after birth. Ocular disease may affect this process. We aimed to determine the relative frequency of ocular conditions causing vision impairment in the pediatric population and characterize the refractive anomalies present. We also compared the causes of vision impairment in children today to those between 1974 and 1981. Causes of vision impairment and refractive data of 872 children attending a pediatric low-vision clinic from 1985 to 2002 were retrospectively collated. As a result of associated impairments, refractive data were not available for 59 children. An analysis was made of the causes of vision impairment, the distribution of refractive errors in children with vision impairment, and the average type of refractive error for the most commonly seen conditions. We found that cortical or cerebral vision impairment (CVI) was the most common condition causing vision impairment, accounting for 27.6% of cases. This was followed by albinism (10.6%), retinopathy of prematurity (ROP; 7.0%), optic atrophy (6.2%), and optic nerve hypoplasia (5.3%). Vision impairment was associated with ametropia; fewer than 25% of the children had refractive errors < or = +/-1 D. The refractive error frequency plots (for 0 to 2-, 6 to 8-, and 12 to 14-year age bands) had a Gaussian distribution indicating that the emmetropization process was abnormal. The mean spherical equivalent refractive error of the children (n = 813) was +0.78 +/- 6.00 D with 0.94 +/- 1.24 D of astigmatism and 0.92 +/- 2.15 D of anisometropia. Most conditions causing vision impairment such as albinism were associated with low amounts of hyperopia. Moderate myopia was observed in children with ROP. The relative frequency of ocular conditions causing vision impairment in children has changed since the 1970s. Children with vision impairment often have an associated ametropia suggesting that the emmetropization system is also impaired.

  5. Influence of stromal refractive index and hydration on corneal laser refractive surgery.

    PubMed

    de Ortueta, Diego; von Rüden, Dennis; Magnago, Thomas; Arba Mosquera, Samuel

    2014-06-01

    To evaluate the influence of the stromal refractive index and hydration on postoperative outcomes in eyes that had corneal laser refractive surgery using the Amaris laser system. Augenzentrum Recklinghausen, Recklinghausen, Germany. Comparative case series. At the 6-month follow-up, right eyes were retrospectively analyzed. The effect of the stromal refractive index and hydration on refractive outcomes was assessed using univariate linear and multilinear correlations. Sixty eyes were analyzed. Univariate linear analyses showed that the stromal refractive index and hydration were correlated with the thickness of the preoperative exposed stroma and was statistically different for laser in situ keratomileusis and laser-assisted subepithelial keratectomy treatments. Univariate multilinear analyses showed that the spherical equivalent (SE) was correlated with the attempted SE and stromal refractive index (or hydration). Analyses suggest overcorrections for higher stromal refractive index values and for lower hydration values. The stromal refractive index and hydration affected postoperative outcomes in a subtle, yet significant manner. An adjustment toward greater attempted correction in highly hydrated corneas and less intended correction in low hydrated corneas might help optimize refractive outcomes. Mr. Magnago and Dr. Arba-Mosquera are employees of and Dr. Diego de Ortueta is a consultant to Schwind eye-tech-solutions GmbH & Co. KG. Mr. Rüden has no financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Seven-year incidence of uncorrected refractive error among an elderly Chinese population in Shihpai, Taiwan: The Shihpai Eye Study

    PubMed Central

    Kuang, T-M; Tsai, S-Y; Liu, C J-L; Ko, Y-C; Lee, S-M; Chou, P

    2016-01-01

    Purpose To report the 7-year incidence of uncorrected refractive error in a metropolitan Chinese elderly population. Methods The Shihpai Eye Study 2006 included 460/824 (55.8%) subjects (age range 72–94 years old) of 1361 participants in the 1999 baseline survey for a follow-up eye examination. Visual acuity was assessed using a Snellen chart, uncorrected refractive error was defined as presenting visual acuity (naked eye if without spectacles and with distance spectacles if worn) in the better eye of <6/12 that improved to no impairment (≥6/12) after refractive correction. Results The 7-year incidence of uncorrected refractive error was 10.5% (95% confidence interval (CI): 7.6–13.4%). 92.7% of participants with uncorrection and 77.8% with undercorrection were able to improve at least two lines of visual acuity by refractive correction. In multivariate analysis controlling for covariates, uncorrected refractive error was significantly related to myopia (relative risk (RR): 3.15; 95% CI: 1.31–7.58) and living alone (RR: 2.94; 95% CI 1.14–7.53), whereas distance spectacles worn during examination was protective (RR: 0.35; 95% CI: 0.14–0.88). Conclusion Our study indicated that the incidence of uncorrected refractive error was high (10.5%) in this elderly Chinese population. Living alone and myopia are predisposing factors, whereas wearing distance spectacles at examination is protective. PMID:26795416

  7. Global magnitude of visual impairment caused by uncorrected refractive errors in 2004

    PubMed Central

    Pascolini, Donatella; Mariotti, Silvio P; Pokharel, Gopal P

    2008-01-01

    Abstract Estimates of the prevalence of visual impairment caused by uncorrected refractive errors in 2004 have been determined at regional and global levels for people aged 5 years and over from recent published and unpublished surveys. The estimates were based on the prevalence of visual acuity of less than 6/18 in the better eye with the currently available refractive correction that could be improved to equal to or better than 6/18 by refraction or pinhole. A total of 153 million people (range of uncertainty: 123 million to 184 million) are estimated to be visually impaired from uncorrected refractive errors, of whom eight million are blind. This cause of visual impairment has been overlooked in previous estimates that were based on best-corrected vision. Combined with the 161 million people visually impaired estimated in 2002 according to best-corrected vision, 314 million people are visually impaired from all causes: uncorrected refractive errors become the main cause of low vision and the second cause of blindness. Uncorrected refractive errors can hamper performance at school, reduce employability and productivity, and generally impair quality of life. Yet the correction of refractive errors with appropriate spectacles is among the most cost-effective interventions in eye health care. The results presented in this paper help to unearth a formerly hidden problem of public health dimensions and promote policy development and implementation, programmatic decision-making and corrective interventions, as well as stimulate research. PMID:18235892

  8. Prevalence of refractive error and visual impairment among rural school-age children of Goro District, Gurage Zone, Ethiopia.

    PubMed

    Kedir, Jafer; Girma, Abonesh

    2014-10-01

    Refractive error is one of the major causes of blindness and visual impairment in children; but community based studies are scarce especially in rural parts of Ethiopia. So, this study aims to assess the prevalence of refractive error and its magnitude as a cause of visual impairment among school-age children of rural community. This community-based cross-sectional descriptive study was conducted from March 1 to April 30, 2009 in rural villages of Goro district of Gurage Zone, found south west of Addis Ababa, the capital of Ethiopia. A multistage cluster sampling method was used with simple random selection of representative villages in the district. Chi-Square and t-tests were used in the data analysis. A total of 570 school-age children (age 7-15) were evaluated, 54% boys and 46% girls. The prevalence of refractive error was 3.5% (myopia 2.6% and hyperopia 0.9%). Refractive error was the major cause of visual impairment accounting for 54% of all causes in the study group. No child was found wearing corrective spectacles during the study period. Refractive error was the commonest cause of visual impairment in children of the district, but no measures were taken to reduce the burden in the community. So, large scale community level screening for refractive error should be conducted and integrated with regular school eye screening programs. Effective strategies need to be devised to provide low cost corrective spectacles in the rural community.

  9. [Epidemiologic study of refractive errors in schoolchildren in socioeconomically deprived regions in Tunisia].

    PubMed

    Ayed, T; Sokkah, M; Charfi, O; El Matri, L

    2002-09-01

    This study's purpose was to estimate the prevalence of common refractive errors in schoolchildren in low socioeconomic regions in Tunisia and to assess their effect on school performance. This was a cross-sectional study done from November 1999 to January 2000 within the context of health care screening campaigns carried out by volunteer ophthalmologists and opticians in low-end socioeconomic regions in Tunisia. The concerned population was schoolchildren living in the cities of Tunis and Tabarka (North), Kerkena (Center), and Tozeur (South). We examined a total of 708 children with a mean age of 11.9 +/-3.21 years (from 6 to 20 years) and a sex ratio of 0.84. A cycloplegic refraction examination was performed on all the children. Statistical analyses with the chi squared test and the Fisher exact test allowed us to calculate the prevalence of the refractive errors totally and separately as well as the distribution according to age, sex, and region. We also searched for a possible relation between refractive errors and academic failure. Among the 708 children, 57.2% [CI(95)=53.4-60] had refractive errors, of which 31.6% [CI(95)=28.2-35.2] were hyperopic, whereas 9.1% [CI(95)=7.1-11.5] were myopic. Astigmatism was found in 16.4% [CI(95)=13.7-19.3]. The prevalence of myopia was significantly higher after the age of fourteen. It increased significantly with age (P=0.0003). The prevalence of hyperopia was significantly higher between the ages of 8 and 11 (P=0.0004). Hyperopic astigmatism was significantly more frequent between 6 and 9 years of age (P=0.001). There was no significant difference regarding sex. However, the distribution of the refractive errors by region showed a significantly high level of myopia in Tunis, Kerkena, and Tozeur. This difference disappeared with increasing age. The study of the effect of these refractive errors on school performance of these children from poor areas showed a significant association between all types of refractive errors and academic failure, with an odds ratio of 2.13 for all types of refractive errors, 2.69 for hyperopia, 2.87 for myopia, and 2.73 for astigmatism. This study showed the prevalence of refractive errors in a poor population of schoolchildren and emphasized the importance of such examinations. The ability of a child to participate in the educational experience is at least partially dependent on good vision.

  10. TOPOGRAPHICALLY GUIDED LASIK FOR MYOPIA USING THE NIDEK CXII CUSTOMIZED ASPHERIC TREATMENT ZONE (CATZ)

    PubMed Central

    Waring, George; Dougherty, Paul J.; Chayet, Arturo; Fischer, Jeffery; Fant, Barbara; Stevens, Gary; Bains, Harkaran S.

    2007-01-01

    Purpose To assess the efficacy, predictability, and safety of topography-guided laser in situ keratomileusis (LASIK) for the surgical correction of low to moderate myopia with astigmatism using the Nidek CXIII excimer laser equipped with the customized aspheric treatment zone (CATz) algorithm. Methods In a multicenter US Food and Drug Administration study of topography-guided LASIK, 4 centers enrolled 135 eyes with manifest refraction sphere that ranged from −0.50 to −7.00 D (mean, −3.57 ± 1.45) with up to −4.00 D of astigmatism (mean, −1.02 ± 0.64 D). The intended outcome was plano in all eyes. Refractive outcomes and higher-order aberrations were analyzed preoperatively and postoperatively. Patient satisfaction was assessed using both the validated Refractive Status and Vision Profile (RSVP) questionnaire and a questionnaire designed for this study. Six-month postoperative outcomes are reported here. Results By 6 months postoperatively, the manifest refraction spherical equivalent (MRSE) for all eyes was −0.09 ± 0.31 D. Six months postoperatively, 116 of 131 eyes (88.55%) had an uncorrected visual acuity of 20/20 or better, and 122 of 131 eyes (93.13%) had a MRSE within ±0.50 D. Distance best spectacle-corrected visual acuity (BSCVA) increased by 2 or more lines in 21 of 131 eyes (19.01%), and no eyes lost 2 lines or more of BSCVA. The total ocular higher-order aberrations root-mean-square increased by 0.04 μm postoperatively. Patients reported significantly fewer night driving and glare and halo symptoms postoperatively than preoperatively. Conclusions Nidek CXIII CATz treatment of myopia with astigmatism is safe, efficacious, and predictable, and it reduces patient symptoms associated with night driving and glare and halo symptoms. PMID:18427614

  11. Effect of mitomycin-C on the variance in refractive outcomes after photorefractive keratectomy.

    PubMed

    Sy, Mary Ellen; Zhang, Lijun; Yeroushalmi, Allen; Huang, Derek; Hamilton, D Rex

    2014-12-01

    To compare the variance in manifest refraction spherical equivalent (MRSE) after photorefractive keratectomy (PRK) with mitomycin-C (MMC), PRK without MMC, and laser in situ keratomileusis (LASIK) for the treatment of myopic astigmatism. Jules Stein Eye Institute, University of California, Los Angeles, Los Angeles, California, USA. Retrospective case series. Patients were classified into 3 groups of preoperative refraction-matched eyes as follows: PRK with MMC 0.02%, PRK without MMC, and LASIK. The preoperative and postoperative MRSE, preoperative corrected distance visual acuity, and postoperative uncorrected distance visual acuity (UDVA) were analyzed. Each group comprised 30 eyes. Follow-up was at least 6 months in the LASIK group and 12 months in the 2 PRK groups. There were no statistically significant differences in the mean preoperative MRSE (P=.95) or postoperative MRSE (P=.06) between the 3 groups. The mean postoperative MRSE was -0.07 diopter (D) ± 0.47 (SD), -0.14 ± 0.26 D, and 0.02 ± 0.25 D in the PRK with MMC 0.02% group, PRK without MMC group, and LASIK group, respectively. The variance in the postoperative MRSE in the PRK with MMC 0.02% group was significantly higher than that in the PRK without MMC group (P=.002) and in the LASIK group (P=.001). There was no statistically significant difference in the mean postoperative UDVA between the 3 groups (P=.47). Refractive outcomes after PRK for myopia were more variable when MMC 0.02% was used. This should be weighed against the advantage of intraoperative MMC use in reducing haze after PRK. Copyright © 2014 ASCRS and ESCRS. All rights reserved.

  12. Prevalence of refractive errors among school children in gondar town, northwest ethiopia.

    PubMed

    Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete

    2012-10-01

    Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment.

  13. Nature and Nurture: the complex genetics of myopia and refractive error

    PubMed Central

    Wojciechowski, Robert

    2010-01-01

    The refractive errors, myopia and hyperopia, are optical defects of the visual system that can cause blurred vision. Uncorrected refractive errors are the most common causes of visual impairment worldwide. It is estimated that 2.5 billion people will be affected by myopia alone with in the next decade. Experimental, epidemiological and clinical research has shown that refractive development is influenced by both environmental and genetic factors. Animal models have demonstrated that eye growth and refractive maturation during infancy are tightly regulated by visually-guided mechanisms. Observational data in human populations provide compelling evidence that environmental influences and individual behavioral factors play crucial roles in myopia susceptibility. Nevertheless, the majority of the variance of refractive error within populations is thought to be due to hereditary factors. Genetic linkage studies have mapped two dozen loci, while association studies have implicated more than 25 different genes in refractive variation. Many of these genes are involved in common biological pathways known to mediate extracellular matrix composition and regulate connective tissue remodeling. Other associated genomic regions suggest novel mechanisms in the etiology of human myopia, such as mitochondrial-mediated cell death or photoreceptor-mediated visual signal transmission. Taken together, observational and experimental studies have revealed the complex nature of human refractive variation, which likely involves variants in several genes and functional pathways. Multiway interactions between genes and/or environmental factors may also be important in determining individual risks of myopia, and may help explain the complex pattern of refractive error in human populations. PMID:21155761

  14. Comparison of astigmatism correction using either peripheral corneal relaxing incisions or toric intraocular lenses.

    PubMed

    Muftuoglu, Ilkay Kilic; Aydin Akova, Yonca; Aksoy, Sibel; Unsal, Erkan

    2016-01-01

    To compare the efficacy and short-term stability of toric intraocular lenses (tIOL) and peripheral cornea relaxing incisions (PCRI) during phacoemulsification. Patients with preexisting corneal astigmatism had cataract surgery either with tIOL (AcrySof Toric) (39 eyes of 35 patients) or standard intraocular lens (AcrySof) + PCRIs (38 eyes of 33 patients). Patients were retrospectively evaluated for manifest refraction, corneal topography, and uncorrected and corrected visual acuities preoperatively and at postoperative 1 and 6 months. The Alpins vectorial method was used to analyze the target induced astigmatism (TIA) and surgically induced astigmatism (SIA), magnitude of error (the difference between the magnitude of SIA and TIA) (ME), and correction index. Mean preoperative corneal astigmatism was 2.21 ± 1.32 D in the tIOL group and 2.24 ± 0.96 D in the PCRI group; the difference was not significant. The decrease in astigmatism was significant in both groups at last follow-up (64% tIOL group, 32% PCRI group, p<0.01, Wilcoxon signed rank test). The mean remaining refractive astigmatism was significantly higher in the PCRI group than in the tIOL group at 1-month (1.42 ± 1.22, 0.89 ± 0.68, respectively) and 6-month follow-ups (1.75 ± 1.37 D, 0.92 ± 0.72, respectively) (p<0.01). The mean ME was significantly lower (-0.35 versus -0.88) with a higher correction index (0.96 versus 0.56) in the tIOL group at 6 months postoperatively. Both tIOL implantation and using PCRI were effective methods to reduce preoperative astigmatism at the time of the cataract surgery. However, tIOLs provided better remaining astigmatism with a more stable refraction than PCRI.

  15. A Two-Piece Microkeratome-Assisted Mushroom Keratoplasty Improves the Outcomes and Survival of Grafts Performed in Eyes with Diseased Stroma and Healthy Endothelium (An American Ophthalmological Society Thesis)

    PubMed Central

    Busin, Massimo; Madi, Silvana; Scorcia, Vincenzo; Santorum, Paolo; Nahum, Yoav

    2015-01-01

    Purpose: To test the hypothesis that a new microkeratome-assisted penetrating keratoplasty (PK) technique employing transplantation of a two-piece mushroom-shaped graft may result in better visual outcomes and graft survival rates than those of conventional PK. Methods: Retrospective chart review of 96 eyes at low risk and 76 eyes at high risk for immunologic rejection (all with full-thickness central corneal opacity and otherwise healthy endothelium) undergoing mushroom PK between 2004 and 2012 at our Institution. Outcome measures were best-corrected visual acuity (BCVA), refraction, corneal topography, endothelial cell density, graft rejection, and survival probability. Results: Five years postoperatively, BCVA of 20/40 and 20/20 was recorded in 100% and over 50% of eyes, respectively. Mean spherical equivalent of refractive error did not vary significantly over a 5-year period; astigmatism averaged always below 4 diopters, with no statistically significant change over time, and was of the regular type in over 90% of eyes. Endothelial cell density decreased to about 40% of the eye bank count 2 years after mushroom PK and did not change significantly thereafter. Five years postoperatively, probabilities of graft immunologic rejection and graft survival were below 5% and above 95%, respectively. There was no statistically significant difference in endothelial cell loss, graft rejection, and survival probability between low-risk and high-risk subgroups. Conclusions: Refractive and visual outcomes of mushroom PK compare favorably with those of conventional full-thickness keratoplasty. In eyes at high risk for immunologic rejection, mushroom PK provides a considerably higher probability of graft survival than conventional PK. PMID:26538771

  16. Prevalence of the refractive errors by age and gender: the Mashhad eye study of Iran.

    PubMed

    Ostadimoghaddam, Hadi; Fotouhi, Akbar; Hashemi, Hassan; Yekta, Abbasali; Heravian, Javad; Rezvan, Farhad; Ghadimi, Hamidreza; Rezvan, Bijan; Khabazkhoob, Mehdi

    2011-11-01

    Refractive errors are a common eye problem. Considering the low number of population-based studies in Iran in this regard, we decided to determine the prevalence rates of myopia and hyperopia in a population in Mashhad, Iran. Cross-sectional population-based study. Random cluster sampling. Of 4453 selected individuals from the urban population of Mashhad, 70.4% participated. Refractive error was determined using manifest (age > 15 years) and cycloplegic refraction (age ≤ 15 years). Myopia was defined as a spherical equivalent of -0.5 diopter or worse. An spherical equivalent of +0.5 diopter or worse for non-cycloplegic refraction and an spherical equivalent of +2 diopter or worse for cycloplegic refraction was used to define hyperopia. Prevalence of refractive errors. The prevalence of myopia and hyperopia in individuals ≤ 15 years old was 3.64% (95% CI: 2.19-5.09) and 27.4% (95% CI: 23.72-31.09), respectively. The same measurements for subjects > 15 years of age was 22.36% (95% CI: 20.06-24.66) and 34.21% (95% CI: 31.57-36.85), respectively. Myopia was found to increase with age in individuals ≤ 15 years and decrease with age in individuals > 15 years of age. The rate of hyperopia showed a significant increase with age in individuals > 15 years. The prevalence of astigmatism was 25.64% (95% CI: 23.76-27.51). In children and the elderly, hyperopia is the most prevalent refractive error. After hyperopia, astigmatism is also of importance in older ages. Age is the most important demographic factor associated with different types of refractive errors. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  17. A Novel Multi-Camera Calibration Method based on Flat Refractive Geometry

    NASA Astrophysics Data System (ADS)

    Huang, S.; Feng, M. C.; Zheng, T. X.; Li, F.; Wang, J. Q.; Xiao, L. F.

    2018-03-01

    Multi-camera calibration plays an important role in many field. In the paper, we present a novel multi-camera calibration method based on flat refractive geometry. All cameras can acquire calibration images of transparent glass calibration board (TGCB) at the same time. The application of TGCB leads to refractive phenomenon which can generate calibration error. The theory of flat refractive geometry is employed to eliminate the error. The new method can solve the refractive phenomenon of TGCB. Moreover, the bundle adjustment method is used to minimize the reprojection error and obtain optimized calibration results. Finally, the four-cameras calibration results of real data show that the mean value and standard deviation of the reprojection error of our method are 4.3411e-05 and 0.4553 pixel, respectively. The experimental results show that the proposed method is accurate and reliable.

  18. Comparison of astigmatic correction after femtosecond lenticule extraction and wavefront-guided LASIK for myopic astigmatism.

    PubMed

    Ali, Mohamed A; Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Miyake, Toshiyuki; Elewa, Mohamed Ehab M; Komatsu, Mari; Shimizu, Kimiya

    2014-12-01

    To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and wavefront-guided LASIK in eyes with myopic astigmatism. Fifty-eight eyes of 41 patients undergoing FLEx and 49 eyes of 29 patients undergoing wavefront-guided LASIK to correct myopic astigmatism were examined. Visual acuity, cylindrical refraction, predictability of the astigmatic correction, and astigmatic vector components were compared between groups 6 months after surgery. There was no statistically significant difference in manifest cylindrical refraction (P = .08) or percentage of eyes within ± 0.50 diopter (D) of its refraction (P = .11) between the surgical procedures. The index of success in FLEx was statistically significantly better than that of wavefront-guided LASIK (P = .02), although there was no significant difference between the groups in other indices (eg, surgically induced astigmatism, target-induced astigmatism, astigmatic correction index, angle of error, difference vector, and flattening index). Subgroup analysis showed that FLEx had a better index of success (P = .02) and difference vector (P = .04) than wavefront-guided LASIK in the low cylinder subgroup; the angle of error in FLEx was significantly smaller than that of wavefront-guided LASIK in the moderate cylinder subgroup (P = .03). Both FLEx and wavefront-guided LASIK worked well for the correction of myopic astigmatism by the 6-month follow-up visit. Although FLEx had a better index of success than wavefront-guided LASIK when using vector analysis, it appears equivalent to wavefront-guided LASIK in terms of visual acuity and the correction of astigmatism. Copyright 2014, SLACK Incorporated.

  19. Anterior chamber depth studies.

    PubMed

    Hoffer, Kenneth J; Savini, Giacomo

    2015-09-01

    To compare the anterior chamber depth (ACD; corneal epithelium to lens) using 3 modalities and compare the change 1 day and 3 months postoperatively. Private practice, Santa Monica, California, USA. Nonrandomized prospective series. The mean optical pachymetry and immersion ultrasound (US) of the ACD and partial coherence interferometry (PCI) were measured. Optical pachymetry ACD was measured in 675 eyes postoperatively at 1 day and 3 months. The optical pachymetry ACD in 492 eyes was 3.17 mm ± 0.42 (SD); by immersion US, it was 2.99 ± 0.51 mm (0.18 mm deeper; P < .0001). In 178 eyes, the optical pachymetry ACD was 3.23 ± 0.45 mm; the PCI was 3.19 ± 0.48 mm (0.04 mm deeper), which was not statistically different (P > .05). In 675 eyes, optical pachymetry ACD preoperatively was 3.19 ± 0.40 mm. The postoperative 1-day optical pachymetry ACD was 4.35 ± 0.35 mm with a mean refractive error of -0.30 diopter (D); the final 3-month optical pachymetry ACD was 4.47 ± 0.31 mm, with a mean refractive error of -0.07 D (P < .0001). This is a mean intraocular lens (IOL) position shift of +0.12 mm posteriorly; the +0.23 D change represents a ratio of 1.92 D/mm of IOL axial movement. The PCI ACD was comparable with optical pachymetry, but careful immersion US led to a 0.18 mm shorter ACD reading that cannot be corrected by sound velocity. The posterior capsule contracted and moved the IOL posteriorly 0.12 mm, resulting in 0.23 D hyperopic shift. Dr. Hoffer owns the registered trademark name "Hoffer(®)" and receives royalties for its commercial use from Alcon Laboratories, Inc., Appasamy Associates, Carl Zeiss Meditec AG, DGH Technology, Inc., Ellex iScience, Inc., Haag-Streit AG, Nidek Co., Ltd., Tomey Corp., Topcon Medical Systems, Inc., and Ziemer USA, Inc., as well as royalties from Slack, Inc. for the textbook IOL Power. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Comparison of the Early Clinical Outcomes between Combined Small-Incision Lenticule Extraction and Collagen Cross-Linking versus SMILE for Myopia.

    PubMed

    Ng, Alex L K; Chan, Tommy C Y; Cheng, George P M; Jhanji, Vishal; Ye, Cong; Woo, Victor C P; Lai, Jimmy S M

    2016-01-01

    Background. To compare the early outcome of combined SMILE and collagen crosslinking (SMILE Xtra) with SMILE. Method. Prospective, comparative interventional study of 21 eyes receiving SMILE Xtra using a low energy protocol and 32 control eyes receiving SMILE only. The outcomes were compared at 1, 3, and 6 months postoperatively. Results. Both groups had myopia with spherical equivalent refraction (SEQ) > 4.00 D. The SMILE Xtra group had thinner preoperative central corneal thickness and residual stromal bed thickness (p < 0.021). At 6 months, no eyes lost more than 1 line in corrected distance visual acuity. The safety index was 0.96 ± 0.06 and 1.00 ± 0.00 in SMILE Xtra and control, respectively (p < 0.001). 89% and 94% of eyes were within ±0.50 D of target refraction, respectively, with the mean error in SEQ correction being -0.17 ± 0.26 D for SMILE Xtra and +0.03 ± 0.25 D for control (p = 0.021). The efficacy index was 0.88 ± 0.13 and 0.97 ± 0.06, respectively (p = 0.005). Conclusion. SMILE Xtra had good overall safety profile and predictability at 6 months. However, when compared with control, the safety index and efficacy index were statistically significantly lower in the early postoperative period.

  1. Retinal measurements using time domain optical coherence tomography imaging before and after myopic Lasik

    PubMed Central

    Lei, Feng; Burns, Stephen A.; shao, Liqin; Yang, Yabo

    2014-01-01

    Purpose To compare retinal measurements obtained by time domain optical coherence tomography (OCT) devices before and after myopic laser in situ keratomileusis (Lasik) and to assess the interaction of Lasik and retinal structures as measured by time domain OCT. Methods 53 patients randomly selected participated in the study. Only the right eye of each subject was included in the study. Comprehensive ophthalmic examinations including refraction examination, slitlamp examination, dilated fundus examination, corneal topography, corneal thickness, intraocular pressure, and retinal Stratus OCT scans were acquired for each patient before myopic Lasik and 3 months after surgery. Results Total macular volume (TMV) changed significantly between preoperative and postoperative measurements (p=0.003). No statistical differences were found between preoperative and postoperative disc area, rim area, cup/disk vert. ratio, or average foveal thickness (p>0.05). The variation in TMV correlated significantly with the change in spherical refraction equivalent, maximal corneal curvature, minimal corneal curvature, and corneal ablation depth. Conclusion Most retinal OCT measurements undergo no obvious changes after myopic Lasik. The increased TMV measurements we measured after Lasik seem to be correlated with the alteration in corneal shape. The exact mechanism for this change is not clear, while we examined several possibilities including subclinical macular edema, magnification changes, errors in OCT analysis and IOP, none of these seem to be a likely cause. PMID:22512373

  2. [Impact of an Aspherical Aberration Correcting Monofocal Intraocular Lens on Patient Satisfaction for Daily Life Activities: The Heidelberg Daily Task Evaluation (DATE) Questionnaire].

    PubMed

    Kretz, F T A; Son, H; Liebing, S; Tandogan, T; Auffarth, G U

    2015-08-01

    A clinical evaluation of the functional results and its impact on daily activities of an aspherical, aberration correcting intraocular lens (IOL) was undertaken. Twenty-one patients aged from 50 to 83 years underwent cataract surgery with implantation of the aspheric IOL (Tecnis ZCB00, Abbott Medical Optics). They were evaluated 2 to 4 months after surgery for their subjective satisfaction of vision quality and its impact on performance of daily activities as well as functional results and refractive outcome. Patients were asked to fill out a questionnaire - the Heidelberg DATE (DAily Tasks Evaluation) questionnaire. Significant changes from pre- to postoperative results were found in refraction (p ≤ 0.03), with a mean prediction error of + 0.21 ± 0.43 D. UDVA and CDVA improved significantly (p < 0.01), with a postoperative CDVA of 0.0 logMAR or better in 97.1 % of eyes. All patients would recommend the procedure to a relative or a friend and 93.8 % of patients reported to be satisfied with the outcome. The implantation of the aspheric IOL Tecnis ZCB00 after cataract surgery allows the restoration of visual function, providing an optimised optical quality and a high level of patient satisfaction. Georg Thieme Verlag KG Stuttgart · New York.

  3. Reduced vision and refractive errors, results from a school vision screening program in Kanchanpur District of far western Nepal.

    PubMed

    Awasthi, S; Pant, B P; Dhakal, H P

    2010-01-01

    At present there is no data available on reduced vision and refractive errors in school children of far western Nepal. So, school screening records were used to obtain data useful for planning of refractive services. Data are provided from school screening conducted by Geta Eye Hospital during February/March 2008. The cases with complete data sets on visual acuity, refractive error and age were included and analyzed using computer software. Of 1165 children (mean age 11.6 ± 2.5 years) examined, 98.8% (n = 1151) had uncorrected visual acuity of 6/9 and better in at least one eye whereas 1.2% (n = 14) had acuity 6/12 and worse in both eyes. Among them, either eye of 9 children improved to 6/9 and better with correction. However, visual acuity was 6/12 and worse in both eyes of 5 children even after correction. There were 24 children with refractive errors (myopia, 1.54%; n = 18 and hypermetropia, 0.51%; n = 6) in at least one eye. The spherical equivalent refraction was not significantly different with age and gender. The incidence of reduced vision and refractive errors among school children of this semi rural district were low.

  4. High Prevalence of Refractive Errors in 7 Year Old Children in Iran.

    PubMed

    Hashemi, Hassan; Yekta, Abbasali; Jafarzadehpur, Ebrahim; Ostadimoghaddam, Hadi; Etemad, Koorosh; Asharlous, Amir; Nabovati, Payam; Khabazkhoob, Mehdi

    2016-02-01

    The latest WHO report indicates that refractive errors are the leading cause of visual impairment throughout the world. The aim of this study was to determine the prevalence of myopia, hyperopia, and astigmatism in 7 yr old children in Iran. In a cross-sectional study in 2013 with multistage cluster sampling, first graders were randomly selected from 8 cities in Iran. All children were tested by an optometrist for uncorrected and corrected vision, and non-cycloplegic and cycloplegic refraction. Refractive errors in this study were determined based on spherical equivalent (SE) cyloplegic refraction. From 4614 selected children, 89.0% participated in the study, and 4072 were eligible. The prevalence rates of myopia, hyperopia and astigmatism were 3.04% (95% CI: 2.30-3.78), 6.20% (95% CI: 5.27-7.14), and 17.43% (95% CI: 15.39-19.46), respectively. Prevalence of myopia (P=0.925) and astigmatism (P=0.056) were not statistically significantly different between the two genders, but the odds of hyperopia were 1.11 (95% CI: 1.01-2.05) times higher in girls (P=0.011). The prevalence of with-the-rule astigmatism was 12.59%, against-the-rule was 2.07%, and oblique 2.65%. Overall, 22.8% (95% CI: 19.7-24.9) of the schoolchildren in this study had at least one type of refractive error. One out of every 5 schoolchildren had some refractive error. Conducting multicenter studies throughout the Middle East can be very helpful in understanding the current distribution patterns and etiology of refractive errors compared to the previous decade.

  5. Clinical vision characteristics of the congenital achromatopsias. I. Visual acuity, refractive error, and binocular status.

    PubMed

    Haegerstrom-Portnoy, G; Schneck, M E; Verdon, W A; Hewlett, S E

    1996-07-01

    Visual acuity, refractive error, and binocular status were determined in 43 autosomal recessive (AR) and 15 X-linked (XL) congenital achromats. The achromats were classified by color matching and spectral sensitivity data. Large interindividual variation in refractive error and visual acuity was present within each achromat group (complete AR, incomplete AR, and XL). However, the number of individuals with significant interocular acuity differences is very small. Most XLs are myopic; ARs show a wide range of refractive error from high myopia to high hyperopia. Acuity of the AR and XL groups was very similar. With-the-rule astigmatism of large amount is very common in achromats, particularly ARs. There is a close association between strabismus and interocular acuity differences in the ARs, with the fixating eye having better than average acuity. The large overlap of acuity and refractive error of XL and AR achromats suggests that these measures are less useful for differential diagnosis than generally indicated by the clinical literature.

  6. Comparison between refractometer and retinoscopy in determining refractive errors in children--false doubt.

    PubMed

    Pokupec, Rajko; Mrazovac, Danijela; Popović-Suić, Smiljka; Mrazovac, Visnja; Kordić, Rajko; Petricek, Igor

    2013-04-01

    Early detection of a refractive error and its correction are extremely important for the prevention of amblyopia (poor vision). The golden standard in the detection of refractive errors is retinoscopy--a method where the pupils are dilated in order to exclude accomodation. This results in a more accurate measurement of a refractive error. Automatic computer refractometer is also in use. The study included 30 patients, 15 boys, 15 girls aged 4-16. The first examination was conducted with refractometer on narrow pupils. Retinoscopy, followed by another examination with refractometer was performed on pupils dilated with mydriatic drops administered 3 times. The results obtained with three methods were compared. They indicate that in narrow pupils the autorefractometer revealed an increased diopter value in nearsightedness (myopia), the minus overcorrection, whereas findings obtained with retinoscopy and autorefractometer in mydriasis cycloplegia, were much more accurate. The results were statistically processed, which confirmed the differences between obtained measurements. These findings are consistent with the results of studies conducted by other authors. Automatic refractometry on narrow pupils has proven to be a method for detection of refractive errors in children. However, the exact value of the refractive error is obtained only in mydriasis--with retinoscopy or an automatic refractometer on dilated pupils.

  7. Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial

    PubMed Central

    2012-01-01

    Background Small incision lenticule extraction or SMILE is a novel form of ‘flapless’ corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Methods/Design Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> −3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> −3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. Discussion This novel trial will provide information on whether SMILE has comparable, if not superior, refractive outcomes compared to the established LASIK for myopia, thus providing evidence for translation into clinical practice. Trial registration Clinicaltrials.gov NCT01216475. PMID:22647480

  8. Foldable iris-fixated intraocular lens implantation in children.

    PubMed

    Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael

    2012-09-01

      To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children.   Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25.   Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications.   Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  9. Refractive states of eyes and associations between ametropia and age, breed, and axial globe length in domestic cats.

    PubMed

    Konrade, Kricket A; Hoffman, Allison R; Ramey, Kelli L; Goldenberg, Ruby B; Lehenbauer, Terry W

    2012-02-01

    To determine the refractive states of eyes in domestic cats and to evaluate correlations between refractive error and age, breed, and axial globe measurements. 98 healthy ophthalmologically normal domestic cats. The refractive state of 196 eyes (2 eyes/cat) was determined by use of streak retinoscopy. Cats were considered ametropic when the mean refractive state was ≥ ± 0.5 diopter (D). Amplitude-mode ultrasonography was used to determine axial globe length, anterior chamber length, and vitreous chamber depth. Mean ± SD refractive state of all eyes was -0.78 ± 1.37 D. Mean refractive error of cats changed significantly as a function of age. Mean refractive state of kittens (≤ 4 months old) was -2.45 ± 1.57 D, and mean refractive state of adult cats (> 1 year old) was -0.39 ± 0.85 D. Mean axial globe length, anterior chamber length, and vitreous chamber depth were 19.75 ± 1.59 mm, 4.66 ± 0.86 mm, and 7.92 ± 0.86 mm, respectively. Correlations were detected between age and breed and between age and refractive states of feline eyes. Mean refractive error changed significantly as a function of age, and kittens had greater negative refractive error than did adult cats. Domestic shorthair cats were significantly more likely to be myopic than were domestic mediumhair or domestic longhair cats. Domestic cats should be included in the animals in which myopia can be detected at a young age, with a likelihood of progression to emmetropia as cats mature.

  10. Relative Peripheral Refractive Error and the Risk of Onset and Progression of Myopia in Children

    PubMed Central

    Sinnott, Loraine T.; Mitchell, G. Lynn; Jones-Jordan, Lisa A.; Moeschberger, Melvin L.; Cotter, Susan A.; Kleinstein, Robert N.; Manny, Ruth E.; Twelker, J. Daniel; Zadnik, Karla

    2011-01-01

    Purpose. To investigate whether relative peripheral hyperopia is a risk factor for either the onset of myopia in children or the rate of myopic progression. Methods. The risk of myopia onset was assessed in 2043 nonmyopic third-grade children (mean age ± SD = 8.8 ± 0.52 years) participating in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study between 1995 and 2007, 324 of whom became myopic by the eighth grade. Progression analyses used data from 774 myopic children in grades 1 to 8. Foveal and relative peripheral refractive error 30° in the nasal visual field was measured annually by using cycloplegic autorefraction. Axial length was measured by A-scan ultrasonography. Results. The association between more hyperopic relative peripheral refractive error in the third grade and the risk of the onset of myopia by the eighth grade varied by ethnic group (Asian children odds ratio [OR] = 1.56, 95% confidence interval [CI] = 1.06–2.30; African-American children OR = 0.75, 95% CI = 0.58–0.96; Hispanics, Native Americans, and whites showed no significant association). Myopia progression was greater per diopter of more hyperopic relative peripheral refractive error, but only by a small amount (−0.024 D per year; P = 0.02). Axial elongation was unrelated to the average relative peripheral refractive error (P = 0.77), regardless of ethnicity. Conclusions. Relative peripheral hyperopia appears to exert little consistent influence on the risk of the onset of myopic refractive error, on the rate of myopia progression, or on axial elongation. PMID:20739476

  11. Prevalence of refractive errors in children in Equatorial Guinea.

    PubMed

    Soler, Margarita; Anera, Rosario G; Castro, José J; Jiménez, Raimundo; Jiménez, José R

    2015-01-01

    The aim of this work is to evaluate the epidemiological aspects of the refractive errors in school-aged children in Malabo (Island of Bioko), Equatorial Guinea (western-central Africa). A total of 425 schoolchildren (209 male subjects and 216 female subjects, aged between 6 and 16 years) were examined to evaluate their refraction errors in Malabo, Equatorial Guinea (western-central Africa). The examination included autorefraction with cycloplegia, measurement of visual acuity (VA) for far vision, and the curvature radii of the main meridians of the anterior surface of the cornea. A low prevalence of myopia was found (≤-0.50 diopters [D] spherical equivalent), with unilateral and bilateral myopia being 10.4 and 5.2%, respectively. The prevalence of unilateral and bilateral hypermetropia (≥2.0 D spherical equivalent) was 3.1 and 1.6%, respectively. Astigmatism (≤-0.75 D) was found in unilateral form in 32.5% of these children, whereas bilateral astigmatism was found in 11.8%. After excluding children having any ocular pathology, the low prevalence of high refractive errors signified good VA in these children. Significant differences were found in the distribution of the refractive errors by age and type of schooling (public or private) but not by sex. In general, the radii of the anterior of the cornea did not vary significantly with age. The mean refractive errors found were low and therefore VA was high in these children. There was a low prevalence of myopia, with significantly higher values in those who attended private schools (educationally and socioeconomically more demanding). Astigmatism was the most frequent refractive error.

  12. Reducing visual deficits caused by refractive errors in school and preschool children: results of a pilot school program in the Andean region of Apurimac, Peru.

    PubMed

    Latorre-Arteaga, Sergio; Gil-González, Diana; Enciso, Olga; Phelan, Aoife; García-Muñoz, Angel; Kohler, Johannes

    2014-01-01

    Refractive error is defined as the inability of the eye to bring parallel rays of light into focus on the retina, resulting in nearsightedness (myopia), farsightedness (Hyperopia) or astigmatism. Uncorrected refractive error in children is associated with increased morbidity and reduced educational opportunities. Vision screening (VS) is a method for identifying children with visual impairment or eye conditions likely to lead to visual impairment. To analyze the utility of vision screening conducted by teachers and to contribute to a better estimation of the prevalence of childhood refractive errors in Apurimac, Peru. Design : A pilot vision screening program in preschool (Group I) and elementary school children (Group II) was conducted with the participation of 26 trained teachers. Children whose visual acuity was<6/9 [20/30] (Group I) and ≤ 6/9 (Group II) in one or both eyes, measured with the Snellen Tumbling E chart at 6 m, were referred for a comprehensive eye exam. Specificity and positive predictive value to detect refractive error were calculated against clinical examination. Program assessment with participants was conducted to evaluate outcomes and procedures. A total sample of 364 children aged 3-11 were screened; 45 children were examined at Centro Oftalmológico Monseñor Enrique Pelach (COMEP) Eye Hospital. Prevalence of refractive error was 6.2% (Group I) and 6.9% (Group II); specificity of teacher vision screening was 95.8% and 93.0%, while positive predictive value was 59.1% and 47.8% for each group, respectively. Aspects highlighted to improve the program included extending training, increasing parental involvement, and helping referred children to attend the hospital. Prevalence of refractive error in children is significant in the region. Vision screening performed by trained teachers is a valid intervention for early detection of refractive error, including screening of preschool children. Program sustainability and improvements in education and quality of life resulting from childhood vision screening require further research.

  13. The Contributions of Near Work and Outdoor Activity to the Correlation Between Siblings in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study

    PubMed Central

    Jones-Jordan, Lisa A.; Sinnott, Loraine T.; Graham, Nicholas D.; Cotter, Susan A.; Kleinstein, Robert N.; Manny, Ruth E.; Mutti, Donald O.; Twelker, J. Daniel; Zadnik, Karla

    2014-01-01

    Purpose. We determined the correlation between sibling refractive errors adjusted for shared and unique environmental factors using data from the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study. Methods. Refractive error from subjects' last study visits was used to estimate the intraclass correlation coefficient (ICC) between siblings. The correlation models used environmental factors (diopter-hours and outdoor/sports activity) assessed annually from parents by survey to adjust for shared and unique environmental exposures when estimating the heritability of refractive error (2*ICC). Results. Data from 700 families contributed to the between-sibling correlation for spherical equivalent refractive error. The mean age of the children at the last visit was 13.3 ± 0.90 years. Siblings engaged in similar amounts of near and outdoor activities (correlations ranged from 0.40–0.76). The ICC for spherical equivalent, controlling for age, sex, ethnicity, and site was 0.367 (95% confidence interval [CI] = 0.304, 0.420), with an estimated heritability of no more than 0.733. After controlling for these variables, and near and outdoor/sports activities, the resulting ICC was 0.364 (95% CI = 0.304, 0.420; estimated heritability no more than 0.728, 95% CI = 0.608, 0.850). The ICCs did not differ significantly between male–female and single sex pairs. Conclusions. Adjusting for shared family and unique, child-specific environmental factors only reduced the estimate of refractive error correlation between siblings by 0.5%. Consistent with a lack of association between myopia progression and either near work or outdoor/sports activity, substantial common environmental exposures had little effect on this correlation. Genetic effects appear to have the major role in determining the similarity of refractive error between siblings. PMID:25205866

  14. Ray tracing evaluation of a technique for correcting the refraction errors in satellite tracking data

    NASA Technical Reports Server (NTRS)

    Gardner, C. S.; Rowlett, J. R.; Hendrickson, B. E.

    1978-01-01

    Errors may be introduced in satellite laser ranging data by atmospheric refractivity. Ray tracing data have indicated that horizontal refractivity gradients may introduce nearly 3-cm rms error when satellites are near 10-degree elevation. A correction formula to compensate for the horizontal gradients has been developed. Its accuracy is evaluated by comparing it to refractivity profiles. It is found that if both spherical and gradient correction formulas are employed in conjunction with meteorological measurements, a range resolution of one cm or less is feasible for satellite elevation angles above 10 degrees.

  15. Linkage analysis of quantitative refraction and refractive errors in the Beaver Dam Eye Study.

    PubMed

    Klein, Alison P; Duggal, Priya; Lee, Kristine E; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E; Klein, Barbara E K

    2011-07-13

    Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10(-4)), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10(-3) and 1.48 × 10(-3), respectively) and to 7p15 of refraction (empiric P = 9.43 × 10(-4)). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10(-3)), a region previously linked to high myopia. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11.

  16. Heritability of lenticular myopia in English Springer spaniels.

    PubMed

    Kubai, Melissa A; Labelle, Amber L; Hamor, Ralph E; Mutti, Donald O; Famula, Thomas R; Murphy, Christopher J

    2013-11-08

    We determined whether naturally-occurring lenticular myopia in English Springer spaniels (ESS) has a genetic component. Streak retinoscopy was performed on 226 related ESS 30 minutes after the onset of pharmacologic mydriasis and cycloplegia. A pedigree was constructed to determine relationships between affected offspring and parents. Estimation of heritability was done in a Bayesian analysis (facilitated by the MCMCglmm package of R) of refractive error in a model, including terms for sex and coat color. Myopia was defined as ≤-0.5 diopters (D) spherical equivalent. The median refractive error for ESS was 0.25 D (range, -3.5 to +4.5 D). Median age was 0.2 years (range, 0.1-15 years). The prevalence of myopia in related ESS was 19% (42/226). The ESS had a strong correlation (r = 0.95) for refractive error between the two eyes. Moderate heritability was present for refractive error with a mean value of 0.29 (95% highest probability density, 0.07-0.50). The distribution of refractive error, and subsequently lenticular myopia, has a moderate genetic component in ESS. Further investigation of genes responsible for regulation of the development of refractive ocular components in canines is warranted.

  17. Myopia in secondary school students in Mwanza City, Tanzania: the need for a national screening programme

    PubMed Central

    Wedner, S H; Ross, D A; Todd, J; Anemona, A; Balira, R; Foster, A

    2002-01-01

    Background/aims: The prevalence of significant refractive errors and other eye diseases was measured in 2511 secondary school students aged 11–27 years in Mwanza City, Tanzania. Risk factors for myopia were explored. Methods: A questionnaire assessed the students’ socioeconomic background and exposure to near work followed by visual acuity assessment and a full eye examination. Non-cycloplegic objective and subjective refraction was done on all participants with visual acuity of worse than 6/12 in either eye without an obvious cause. Results: 154 (6.1%) students had significant refractive errors. Myopia was the leading refractive error (5.6%). Amblyopia (0.4%), strabismus (0.2%), and other treatable eye disorders were uncommon. Only 30.3% of students with significant refractive errors wore spectacles before the survey. Age, sex, ethnicity, father’s educational status, and a family history of siblings with spectacles were significant independent risk factors for myopia. Conclusion: The prevalence of uncorrected significant refractive errors is high enough to justify a regular school eye screening programme in secondary schools in Tanzania. Risk factors for myopia are similar to those reported in European, North-American, and Asian populations. PMID:12386067

  18. Prevalence and predictors of refractive error and spectacle coverage in Nakuru, Kenya: a cross-sectional, population-based study.

    PubMed

    Bastawrous, Andrew; Mathenge, Wanjiku; Foster, Allen; Kuper, Hannah

    2013-10-01

    A cross-sectional study was undertaken in Nakuru, Kenya to assess the prevalence of refractive error and the spectacle coverage in a population aged ≥50 years. Of the 5,010 subjects who were eligible, 4,414 underwent examination (response rate 88.1 %). LogMAR visual acuity was assessed in all participants and refractive error was measured in both eyes using a Topcon auto refractor RM8800. Detailed interviews were undertaken and ownership of spectacles was assessed. Refractive error was responsible for 51.7 % of overall visual impairment (VI), 85.3 % (n = 191) of subjects with mild VI, 42.7 % (n = 152) of subjects with moderate VI, 16.7 % (n = 3) of subjects with severe VI and no cases of blindness. Myopia was more common than hyperopia affecting 59.5 % of those with refractive error compared to 27.4 % for hyperopia. High myopia (<-5.0 DS) was also more common than extreme hyperopia (>+5.0 DS). Of those who needed distance spectacles (spectacle coverage), 25.5 % owned spectacles. In conclusion, the oldest, most poor and least educated are most likely to have no spectacles and they should be specifically targeted when refractive services are put in place.

  19. Prevalence of Refractive Errors Among School Children in Gondar Town, Northwest Ethiopia

    PubMed Central

    Yared, Assefa Wolde; Belaynew, Wasie Taye; Destaye, Shiferaw; Ayanaw, Tsegaw; Zelalem, Eshete

    2012-01-01

    Purpose: Many children with poor vision due to refractive error remain undiagnosed and perform poorly in school. The situation is worse in the Sub-Saharan Africa, including Ethiopia, and current information is lacking. The objective of this study is to determine the prevalence of refractive error among children enrolled in elementary schools in Gondar town, Ethiopia. Materials and Methods: This was a cross-sectional study of 1852 students in 8 elementary schools. Subjects were selected by multistage random sampling. The study parameters were visual acuity (VA) evaluation and ocular examination. VA was measured by staff optometrists with the Snellen E-chart while students with subnormal vision were examined using pinhole, retinoscopy evaluation and subjective refraction by ophthalmologists. Results: The study cohort was comprised of 45.8% males and 54.2% females from 8 randomly selected elementary schools with a response rate of 93%. Refractive errors in either eye were present in 174 (9.4%) children. Of these, myopia was diagnosed in 55 (31.6%) children in the right and left eyes followed by hyperopia in 46 (26.4%) and 39 (22.4%) in the right and left eyes respectively. Low myopia was the most common refractive error in 61 (49.2%) and 68 (50%) children for the right and left eyes respectively. Conclusions: Refractive error among children is a common problem in Gondar town and needs to be assessed at every health evaluation of school children for timely treatment. PMID:23248538

  20. Prevalence of refractive error among preschool children in an urban population: the Baltimore Pediatric Eye Disease Study.

    PubMed

    Giordano, Lydia; Friedman, David S; Repka, Michael X; Katz, Joanne; Ibironke, Josephine; Hawes, Patricia; Tielsch, James M

    2009-04-01

    To determine the age-specific prevalence of refractive errors in white and African-American preschool children. The Baltimore Pediatric Eye Disease Study is a population-based evaluation of the prevalence of ocular disorders in children aged 6 to 71 months in Baltimore, Maryland. Among 4132 children identified, 3990 eligible children (97%) were enrolled and 2546 children (62%) were examined. Cycloplegic autorefraction was attempted in all children with the use of a Nikon Retinomax K-Plus 2 (Nikon Corporation, Tokyo, Japan). If a reliable autorefraction could not be obtained after 3 attempts, cycloplegic streak retinoscopy was performed. Mean spherical equivalent (SE) refractive error, astigmatism, and prevalence of higher refractive errors among African-American and white children. The mean SE of right eyes was +1.49 diopters (D) (standard deviation [SD] = 1.23) in white children and +0.71 D (SD = 1.35) in African-American children (mean difference of 0.78 D; 95% confidence interval [CI], 0.67-0.89). Mean SE refractive error did not decline with age in either group. The prevalence of myopia of 1.00 D or more in the eye with the lesser refractive error was 0.7% in white children and 5.5% in African-American children (relative risk [RR], 8.01; 95% CI, 3.70-17.35). The prevalence of hyperopia of +3 D or more in the eye with the lesser refractive error was 8.9% in white children and 4.4% in African-American children (RR, 0.49; 95% CI, 0.35-0.68). The prevalence of emmetropia (<-1.00 D to <+1.00 D) was 35.6% in white children and 58.0% in African-American children (RR, 1.64; 95% CI, 1.49-1.80). On the basis of published prescribing guidelines, 5.1% of the children would have benefited from spectacle correction. However, only 1.3% had been prescribed correction. Significant refractive errors are uncommon in this population of urban preschool children. There was no evidence for a myopic shift over this age range in this cross-sectional study. A small proportion of preschool children would likely benefit from refractive correction, but few have had this prescribed.

  1. Nature versus nurture: A systematic approach to elucidate gene-environment interactions in the development of myopic refractive errors.

    PubMed

    Miraldi Utz, Virginia

    2017-01-01

    Myopia is the most common eye disorder and major cause of visual impairment worldwide. As the incidence of myopia continues to rise, the need to further understand the complex roles of molecular and environmental factors controlling variation in refractive error is of increasing importance. Tkatchenko and colleagues applied a systematic approach using a combination of gene set enrichment analysis, genome-wide association studies, and functional analysis of a murine model to identify a myopia susceptibility gene, APLP2. Differential expression of refractive error was associated with time spent reading for those with low frequency variants in this gene. This provides support for the longstanding hypothesis of gene-environment interactions in refractive error development.

  2. Incidence of rainbow glare after laser in situ keratomileusis flap creation with a 60 kHz femtosecond laser.

    PubMed

    Bamba, Sonya; Rocha, Karolinne M; Ramos-Esteban, Jerome C; Krueger, Ronald R

    2009-06-01

    To report the incidence of and factors associated with rainbow glare after laser in situ keratomileusis (LASIK) flap creation with a 60 kHz femtosecond laser. Department of Refractive Surgery, Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. Consecutive patients having LASIK by the same surgeon were questioned during postoperative examinations or by telephone about postoperative rainbow glare (radiating colors around a white light at night). Femtosecond laser (IntraLase) settings included pulse frequency 60 kHz, flap thickness 90 to 110 mum, and spot/line separation 8 mum. Raster energy was 0.8 microJ (75% of eyes) and 1.0 to 1.1 microJ (25%). Excimer laser ablation was performed with the LADAR 4000 or 6000 platform using custom or conventional treatments. Of 260 consecutive patients, 256 (98.5%) were successfully contacted. Fifteen patients (28 eyes) reported postoperative rainbow glare (5.8%), described as 4 to 12 bands of color around a white light, with 6 bands most common. The symptom did not correlate with refractive error, age, or sex but was more frequent at 1.0 microJ or 1.1 microJ raster energy (11.6%) than at 0.8 microJ (4.1%). The incidence followed a bimodal distribution, with the first grouping due to inadequate alignment and higher energy just after laser installation and the second just before a later maintenance service call. Rainbow glare is a mild optical side effect of femtosecond LASIK. In this study, higher raster energy levels and length of time between service calls were associated with the occurrence of rainbow glare.

  3. Recovery of Peripheral Refractive Errors and Ocular Shape in Rhesus Monkeys (Macaca mulatta) with Experimentally Induced Myopia

    PubMed Central

    Huang, Juan; Hung, Li-Fang; Smith, Earl L.

    2012-01-01

    This study aimed to investigate the changes in ocular shape and relative peripheral refraction during the recovery from myopia produced by form deprivation (FD) and hyperopic defocus. FD was imposed in 6 monkeys by securing a diffuser lens over one eye; hyperopic defocus was produced in another 6 monkeys by fitting one eye with -3D spectacle. When unrestricted vision was re-established, the treated eyes recovered from the vision-induced central and peripheral refractive errors. The recovery of peripheral refractive errors was associated with corresponding changes in the shape of the posterior globe. The results suggest that vision can actively regulate ocular shape and the development of central and peripheral refractions in infant primates. PMID:23026012

  4. Irregular Astigmatism After Corneal Transplantation--Efficacy and Safety of Topography-Guided Treatment.

    PubMed

    Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N

    2016-01-01

    To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.

  5. Three-year changes in epithelial and stromal thickness after PRK or LASIK for high myopia.

    PubMed

    Ivarsen, Anders; Fledelius, Walther; Hjortdal, Jesper Ø

    2009-05-01

    To compare 3-year changes in corneal sublayer thickness after photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). Forty-six patients with spheroequivalent refraction of -6.0 to -8.0 diopters (D) were randomly assigned to PRK or LASIK. One eye from each patient was included in the study. Examinations included manifest refraction and confocal microscopy through focusing (CMTF) and were performed preoperatively and postoperatively at 1 week and at 1, 3, 6, 12, and 36 months. From CMTF scans, the thicknesses of the central cornea (CT), epithelium (ET), stroma (ST), LASIK flap (FT), and residual stromal bed (BT) were calculated. After LASIK, spheroequivalent refraction averaged -0.76 D by 1 week and -1.19 D by 1 month, with no subsequent significant change. ET increased 9.0 +/- 7.0 microm within 1 week and remained constant thereafter. ST increased 12.9 +/- 9.4 microm within 1 year because of increased BT. One week after PRK, refraction averaged -0.23 D and stabilized at -1.42 D by 6 months. By 1 week, ET was reduced by 7.5 +/- 5.7 microm, reached preoperative thickness by 6 months, and increased further 7.3 +/- 6.0 microm by 3 years. ST increased 25.3 +/- 17.2 microm during 1 year, correlating with the postoperative refractive regression. After both procedures, changes in CT also correlated with refractive changes. No other correlations were identified. PRK and LASIK induce a persistent increase in ET that stabilizes 1 week after LASIK and 1 year after PRK. Stromal regrowth is most pronounced after PRK. After LASIK, regrowth is restricted to the residual stromal bed. Postoperative refractive changes correlate with changes in ST (PRK) and CT (PRK and LASIK) but not with changes in ET.

  6. Refractive error at birth and its relation to gestational age.

    PubMed

    Varughese, Sara; Varghese, Raji Mathew; Gupta, Nidhi; Ojha, Rishikant; Sreenivas, V; Puliyel, Jacob M

    2005-06-01

    The refractive status of premature infants is not well studied. This study was done to find the norms of refractive error in newborns at different gestational ages. One thousand two hundred three (1203) eyes were examined for refractive error by streak retinoscopy within the first week of life between June 2001 and September 2002. Tropicamide eye drops (0.8%) with phenylephrine 0.5% were used to achieve cycloplegia and mydriasis. The refractive error was measured in the vertical and horizontal meridia in both eyes and was recorded to the nearest dioptre (D). The neonates were grouped in five gestational age groups ranging from 24 weeks to 43 weeks. Extremely preterm babies were found to be myopic with a mean MSE (mean spherical equivalent) of -4.86 D. The MSE was found to progressively decrease (become less myopic) with increasing gestation and was +2.4 D at term. Astigmatism of more than 1 D spherical equivalent was seen in 67.8% of the eyes examined. Among newborns with > 1 D of astigmatism, the astigmatism was with-the-rule (vertical meridian having greater refractive power than horizontal) in 85% and against-the-rule in 15%. Anisometropia of more than 1 D spherical equivalent was seen in 31% babies. Term babies are known to be hypermetropic, and preterm babies with retinopathy of prematurity (ROP) are known to have myopia. This study provides data on the mean spherical equivalent, the degree of astigmatism, and incidence of anisometropia at different gestational ages. This is the largest study in world literature looking at refractive errors at birth against gestational age. It should help understand the norms of refractive errors in preterm babies.

  7. High Prevalence of Refractive Errors in 7 Year Old Children in Iran

    PubMed Central

    HASHEMI, Hassan; YEKTA, Abbasali; JAFARZADEHPUR, Ebrahim; OSTADIMOGHADDAM, Hadi; ETEMAD, Koorosh; ASHARLOUS, Amir; NABOVATI, Payam; KHABAZKHOOB, Mehdi

    2016-01-01

    Background: The latest WHO report indicates that refractive errors are the leading cause of visual impairment throughout the world. The aim of this study was to determine the prevalence of myopia, hyperopia, and astigmatism in 7 yr old children in Iran. Methods: In a cross-sectional study in 2013 with multistage cluster sampling, first graders were randomly selected from 8 cities in Iran. All children were tested by an optometrist for uncorrected and corrected vision, and non-cycloplegic and cycloplegic refraction. Refractive errors in this study were determined based on spherical equivalent (SE) cyloplegic refraction. Results: From 4614 selected children, 89.0% participated in the study, and 4072 were eligible. The prevalence rates of myopia, hyperopia and astigmatism were 3.04% (95% CI: 2.30–3.78), 6.20% (95% CI: 5.27–7.14), and 17.43% (95% CI: 15.39–19.46), respectively. Prevalence of myopia (P=0.925) and astigmatism (P=0.056) were not statistically significantly different between the two genders, but the odds of hyperopia were 1.11 (95% CI: 1.01–2.05) times higher in girls (P=0.011). The prevalence of with-the-rule astigmatism was 12.59%, against-the-rule was 2.07%, and oblique 2.65%. Overall, 22.8% (95% CI: 19.7–24.9) of the schoolchildren in this study had at least one type of refractive error. Conclusion: One out of every 5 schoolchildren had some refractive error. Conducting multicenter studies throughout the Middle East can be very helpful in understanding the current distribution patterns and etiology of refractive errors compared to the previous decade. PMID:27114984

  8. Novel Myopia Genes and Pathways Identified From Syndromic Forms of Myopia

    PubMed Central

    Loughman, James; Wildsoet, Christine F.; Williams, Cathy; Guggenheim, Jeremy A.

    2018-01-01

    Purpose To test the hypothesis that genes known to cause clinical syndromes featuring myopia also harbor polymorphisms contributing to nonsyndromic refractive errors. Methods Clinical phenotypes and syndromes that have refractive errors as a recognized feature were identified using the Online Mendelian Inheritance in Man (OMIM) database. One hundred fifty-four unique causative genes were identified, of which 119 were specifically linked with myopia and 114 represented syndromic myopia (i.e., myopia and at least one other clinical feature). Myopia was the only refractive error listed for 98 genes and hyperopia and the only refractive error noted for 28 genes, with the remaining 28 genes linked to phenotypes with multiple forms of refractive error. Pathway analysis was carried out to find biological processes overrepresented within these sets of genes. Genetic variants located within 50 kb of the 119 myopia-related genes were evaluated for involvement in refractive error by analysis of summary statistics from genome-wide association studies (GWAS) conducted by the CREAM Consortium and 23andMe, using both single-marker and gene-based tests. Results Pathway analysis identified several biological processes already implicated in refractive error development through prior GWAS analyses and animal studies, including extracellular matrix remodeling, focal adhesion, and axon guidance, supporting the research hypothesis. Novel pathways also implicated in myopia development included mannosylation, glycosylation, lens development, gliogenesis, and Schwann cell differentiation. Hyperopia was found to be linked to a different pattern of biological processes, mostly related to organogenesis. Comparison with GWAS findings further confirmed that syndromic myopia genes were enriched for genetic variants that influence refractive errors in the general population. Gene-based analyses implicated 21 novel candidate myopia genes (ADAMTS18, ADAMTS2, ADAMTSL4, AGK, ALDH18A1, ASXL1, COL4A1, COL9A2, ERBB3, FBN1, GJA1, GNPTG, IFIH1, KIF11, LTBP2, OCA2, POLR3B, POMT1, PTPN11, TFAP2A, ZNF469). Conclusions Common genetic variants within or nearby genes that cause syndromic myopia are enriched for variants that cause nonsyndromic, common myopia. Analysis of syndromic forms of refractive errors can provide new insights into the etiology of myopia and additional potential targets for therapeutic interventions. PMID:29346494

  9. Prevalence of refractive errors in children in India: a systematic review.

    PubMed

    Sheeladevi, Sethu; Seelam, Bharani; Nukella, Phanindra B; Modi, Aditi; Ali, Rahul; Keay, Lisa

    2018-04-22

    Uncorrected refractive error is an avoidable cause of visual impairment which affects children in India. The objective of this review is to estimate the prevalence of refractive errors in children ≤ 15 years of age. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed in this review. A detailed literature search was performed to include all population and school-based studies published from India between January 1990 and January 2017, using the Cochrane Library, Medline and Embase. The quality of the included studies was assessed based on a critical appraisal tool developed for systematic reviews of prevalence studies. Four population-based studies and eight school-based studies were included. The overall prevalence of refractive error per 100 children was 8.0 (CI: 7.4-8.1) and in schools it was 10.8 (CI: 10.5-11.2). The population-based prevalence of myopia, hyperopia (≥ +2.00 D) and astigmatism was 5.3 per cent, 4.0 per cent and 5.4 per cent, respectively. Combined refractive error and myopia alone were higher in urban areas compared to rural areas (odds ratio [OR]: 2.27 [CI: 2.09-2.45]) and (OR: 2.12 [CI: 1.79-2.50]), respectively. The prevalence of combined refractive errors and myopia alone in schools was higher among girls than boys (OR: 1.2 [CI: 1.1-1.3] and OR: 1.1 [CI: 1.1-1.2]), respectively. However, hyperopia was more prevalent among boys than girls in schools (OR: 2.1 [CI: 1.8-2.4]). Refractive error in children in India is a major public health problem and requires concerted efforts from various stakeholders including the health care workforce, education professionals and parents, to manage this issue. © 2018 Optometry Australia.

  10. Effects of horizontal refractivity gradients on the accuracy of laser ranging to satellites

    NASA Technical Reports Server (NTRS)

    Gardner, C. S.

    1976-01-01

    Numerous formulas have been developed to partially correct laser ranging data for the effects of atmospheric refraction. All the formulas assume the atmospheric refractivity profile is spherically symmetric. The effects of horizontal refractivity gradients are investigated by ray tracing through spherically symmetric and three-dimensional refractivity profiles. The profiles are constructed from radiosonde data. The results indicate that the horizontal gradients introduce an rms error of approximately 3 cm when the satellite is near 10 deg elevation. The error decreases to a few millimeters near zenith.

  11. The child self-refraction study results from urban Chinese children in Guangzhou.

    PubMed

    He, Mingguang; Congdon, Nathan; MacKenzie, Graeme; Zeng, Yangfa; Silver, Joshua D; Ellwein, Leon

    2011-06-01

    To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. Cross-sectional study. Chinese school-children aged 12 to 17 years. Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Prevalence of refractive errors in a Brazilian population: the Botucatu eye study.

    PubMed

    Schellini, Silvana Artioli; Durkin, Shane R; Hoyama, Erika; Hirai, Flavio; Cordeiro, Ricardo; Casson, Robert J; Selva, Dinesh; Padovani, Carlos Roberto

    2009-01-01

    To determine the prevalence and demographic associations of refractive error in Botucatu, Brazil. A population-based, cross-sectional prevalence study was conducted, which involved random, household cluster sampling of an urban Brazilian population in Botucatu. There were 3000 individuals aged 1 to 91 years (mean 38.3) who were eligible to participate in the study. Refractive error measurements were obtained by objective refraction. Objective refractive error examinations were performed on 2454 residents within this sample (81.8% of eligible participants). The mean age was 38 years (standard deviation (SD) 20.8 years, Range 1 to 91) and females comprised 57.5% of the study population. Myopia (spherical equivalent (SE) < -0.5 dropters (D)) was most prevalent among those aged 30-39 years (29.7%; 95% confidence interval (CI) 24.8-35.1) and least prevalent among children under 10 years (3.8%; 95% confidence interval (CI) 1.6-7.3). Conversely hypermetropia (SE > 0.5D) was most prevalent among participants under 10 years (86.9%; 95% CI 81.6-91.1) and least prevalent in the fourth decade (32.5%; 95% CI 28.2-37.0). Participants aged 70 years or older bore the largest burden of astigmatism (cylinder at least -0.5D) and anisometropia (difference in SE of > 0.5D) with a prevalence of 71.7% (95% CI 64.8-78.0) 55.0% (95% CI 47.6-62.2) respectively. Myopia and hypermetropia were significantly associated with age in a bimodal manner (P < 0.001), whereas anisometropia and astigmatism increased in line with age (P < 0.001). Multivariate modeling confirmed age-related risk factors for refractive error and revealed several gender, occupation and ethnic-related risk factors. These results represent previously unreported data on refractive error within this Brazilian population. They signal a need to continue to screen for refractive error within this population and to ensure that people have adequate access to optical correction.

  13. Topical cyclosporine a treatment in corneal refractive surgery and patients with dry eye.

    PubMed

    Torricelli, Andre A M; Santhiago, Marcony R; Wilson, Steven E

    2014-08-01

    To evaluate preoperative and postoperative dry eye and the effect of cyclosporine A treatment in patients screened for corneal refractive surgery and treated with photorefractive keratectomy (PRK) or LASIK. A consecutive case series of 1,056 patients screened for corneal refractive surgery from 2007 to 2012 was retrospectively analyzed. The level of preoperative and postoperative dry eye and the responsiveness to topical cyclosporine A treatment were assessed. One eye of each patient was randomly selected. A total of 642 eyes progressed to surgery: 524 (81.6%) and 118 (18.4%) underwent LASIK and PRK, respectively. Of 81 (7.7%) diagnosed as having dry eye, 55 were deemed potential candidates and optimized for refractive surgery. Thirty-seven patients with moderate dry eye were treated with topical cyclosporine A prior to surgery (mean duration: 3.2 ± 2.1 months; range: 1 to 12 months). After cyclosporine A treatment, 28 (75.7%) eyes underwent LASIK, 4 (10.8%) eyes underwent PRK, and 5 (13.5%) eyes were not operated on due to failed treatment of dry eye. Postoperative refractive surgery-induced neurotrophic epitheliopathy (LINE in LASIK) was noted in 132 (27.3%) and 12 (11.1%) eyes that underwent LASIK and PRK, respectively. Topical cyclosporine A was prescribed in 79 LASIK-induced and 3 PRK-induced dry eyes. After 12 months or more of cyclosporine A treatment, 5 (6.1%) eyes continued to have dry eye symptoms or signs. Topical cyclosporine A treatment is effective therapy for optimizing patients for refractive surgery and treatment of new onset or worsened dry eye after surgery. Copyright 2014, SLACK Incorporated.

  14. How close are we? An audit of biometry of a tertiary care hospital in Karachi.

    PubMed

    Siddiqui, Abdul Hameed; Khan, Maria; Hussain, Marium

    2018-01-01

    To evaluate the accuracy of biometry in the post-op phase of cataract surgery. This study was conducted at Liaquat National Hospital, Karachi, from June 2015 to July 2016, and comprised the audit of patients who underwent cataract surgery during the period. Keratometry was done on Haag-Strait manual keratometer and A-scan was done by applanation contact method on SonoMed machine. Theoretic-T formula was used to calculate desired intraocular lens power for all kinds of axial lengths. A single surgeon operated upon the same Alcon Constellation phacoemulsification machine. Postoperative follow-up was done by monitoring auto refraction and visual acuity on days 1, 7, 30 and 90. SPSS 21 was used for data analysis.. Of 244 patients, 121(49.60%) were males and 123(50.40%) were females. There were 123(50.40%) right eyes and 121(49.60%) left eyes. Overall, 132(54.10%) achieved postoperative refraction within ±0.5 D of target and 193(79.10%) within ±1 D of target. Age, gender and laterality had no significant effect on outcomes (p>0.05 each). Postoperative refraction corresponded quite closely with global recommendations.

  15. The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews.

    PubMed

    Mayo-Wilson, Evan; Ng, Sueko Matsumura; Chuck, Roy S; Li, Tianjing

    2017-09-05

    Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. Most systematic reviews of interventions for refractive error are low methodological quality. Following widely accepted guidance, such as Cochrane or Institute of Medicine standards for conducting systematic reviews, would contribute to improved patient care and inform future research.

  16. Refractive error among the elderly in rural Southern Harbin, China.

    PubMed

    Li, Zhijian; Sun, Dianjun; Cuj, Hao; Zhang, Liqiong; Lju, Ping; Yang, Hongbin; Baj, Jie

    2009-01-01

    To estimate the prevalence and associated factors of refractive errors among the elderly in a rural area of Southern Harbin, China. Five thousand and fifty seven subjects (age > or = 50 years) were enumerated for a population-based study. All participants underwent complete ophthalmic evaluation. Refraction was performed by ophthalmic personnel trained in the study procedures. Myopia was defined as spherical equivalent worse than -0.50 diopters (D) and hyperopia as spherical equivalent worse than +0.50 D. Astigmatism was defined as a cylindrical error worse than 0.75D. Association of refractive errors with age, sex, and education were analyzed. Of the 5,057 responders (91.0%), 4,979 were eligible. The mean age was 60.5 (range 50-96) years old. The prevalence of myopia was 9.5% (95% confidence interval [CI], 8.5-10.1) and of hyperopia was 8.9% (95% CI, 7.9-9.5). Astigmatism was evident in 7.6% of the subjects. Myopia, hyperopia and astigmatism increased with increasing age (p<0.001, respectively). Myopia and astigmatism were more common in males, whereas hyperopia was more common in females. We also found that prevalence of refractive error weas associated with education. Myopia was more common in those with higher degrees of education, whereas hyperopia and astigmatism were more common in those with no formal education. This report has provided details of the refractive status in a rural population of Harbin. The prevalence of refractive errors in this population is lower than those reported in other regions of the world.

  17. Uncorrected refractive errors, presbyopia and spectacle coverage: results from a rapid assessment of refractive error survey.

    PubMed

    Marmamula, Srinivas; Keeffe, Jill E; Rao, Gullapalli N

    2009-01-01

    To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 15-50 years using rapid assessment methodology in the Mahabubnagar district of Andhra Pradesh, India. A population-based cross sectional study was conducted using cluster random sampling to enumerate 3,300 subjects from 55 clusters. Unaided, aided and pinhole visual acuity was assessed using a LogMAR chart at a distance of 4 meters. Near vision was assessed using N notation chart. Uncorrected refractive error was defined as presenting visual acuity worse than 6/12 but improving to at least 6/12 or better on using a pinhole. Presbyopia is defined as binocular near vision worse than N8 in subjects aged more than 35 years with binocular distance visual acuity of 6/12 or better. Of the 3,300 subjects enumerated from 55 clusters, 3,203 (97%) subjects were available for examination. Of these, 1,496 (46.7%) were females and 930 (29%) were > or = 40 years. Age and gender adjusted prevalence of uncorrected refractive errors causing visual impairment in the better eye was 2.7% (95% CI, 2.1-3.2%). Presbyopia was present in 690 (63.7%, 95% CI, 60.8-66.6%) subjects aged over 35 years. Spectacle coverage for refractive error was 29% and for presbyopia it was 19%. There is a large unmet need for refractive correction in this area in India. Rapid assessment methods are an effective means of assessing the need for services and the impact of models of care.

  18. [Prevalence of refractive errors in 7 and 8 year-old children in the province of Western Pomerania].

    PubMed

    Muszyńska-Lachota, Izabela; Czepita, Damian; uczyńska, Violetta; Wysiecki, Przemysław

    2005-01-01

    To determine the prevalence of refractive errors in 7 and 8 year-old schoolchildren in the province of Western Pomerania. 140 pupils of elementary schools were examined. Measurements of visual acuity and retinoscopy after cycloplegia were carried out. Prevalence of hyperopia, myopia, and astigmatism was 76.1%, 3.3% and 5.1%, respectively. No statistically significant differences between 7 and 8 year-old children were found. 1. There is a relatively high prevalence of refractive errors, with hyperopia prevailing, among 7 and 8 year-old schoolchildren. 2. Myopia in young children is a cause for concern an further studies. 3. High prevalence of refractive errors in children calls for systematic examination and focused interviewing by medical professionals of the school health care system.

  19. Refractive Outcomes, Contrast Sensitivity, HOAs, and Patient Satisfaction in Moderate Myopia: Wavefront-Optimized Versus Tissue-Saving PRK.

    PubMed

    Nassiri, Nader; Sheibani, Kourosh; Azimi, Abbas; Khosravi, Farinaz Mahmoodi; Heravian, Javad; Yekta, Abasali; Moghaddam, Hadi Ostadi; Nassiri, Saman; Yasseri, Mehdi; Nassiri, Nariman

    2015-10-01

    To compare refractive outcomes, contrast sensitivity, higher-order aberrations (HOAs), and patient satisfaction after photorefractive keratectomy for correction of moderate myopia with two methods: tissue saving versus wavefront optimized. In this prospective, comparative study, 152 eyes (80 patients) with moderate myopia with and without astigmatism were randomly divided into two groups: the tissue-saving group (Technolas 217z Zyoptix laser; Bausch & Lomb, Rochester, NY) (76 eyes of 39 patients) or the wavefront-optimized group (WaveLight Allegretto Wave Eye-Q laser; Alcon Laboratories, Inc., Fort Worth, TX) (76 eyes of 41 patients). Preoperative and 3-month postoperative refractive outcomes, contrast sensitivity, HOAs, and patient satisfaction were compared between the two groups. The mean spherical equivalent was -4.50 ± 1.02 diopters. No statistically significant differences were detected between the groups in terms of uncorrected and corrected distance visual acuity and spherical equivalent preoperatively and 3 months postoperatively. No statistically significant differences were seen in the amount of preoperative to postoperative contrast sensitivity changes between the two groups in photopic and mesopic conditions. HOAs and Q factor increased in both groups postoperatively (P = .001), with the tissue-saving method causing more increases in HOAs (P = .007) and Q factor (P = .039). Patient satisfaction was comparable between both groups. Both platforms were effective in correcting moderate myopia with or without astigmatism. No difference in refractive outcome, contrast sensitivity changes, and patient satisfaction between the groups was observed. Postoperatively, the tissue-saving method caused a higher increase in HOAs and Q factor compared to the wavefront-optimized method, which could be due to larger optical zone sizes in the tissue-saving group. Copyright 2015, SLACK Incorporated.

  20. Longitudinal comparison of outcomes after sub-Bowman keratomileusis and laser in situ keratomileusis: randomized, double-masked study.

    PubMed

    Wong, Rachel Chung Yin; Yu, Marco; Chan, Tommy C Y; Chong, Kelvin K L; Jhanji, Vishal

    2015-05-01

    To compare the outcomes of sub-Bowman keratomileusis (100-μm flap) and laser in situ keratomileusis (LASIK) (120-μm flap) using 150-kHz femtosecond laser. Randomized, double-masked, contralateral clinical trial. One hundred patients (200 eyes) with myopia or myopic astigmatism were included. Postoperative examinations were performed at week 1 and months 1, 3, 6, and 12. Main outcome measures included postoperative uncorrected (UCVA) and best-corrected distance visual acuity (BCVA); manifest refraction spherical equivalent; efficacy and safety indices; corneal thickness; and complications. The mean age of patients was 33.9 ± 7.9 years. Overall, the preoperative UCVA, BCVA, and manifest refraction spherical equivalent were 1.349 ± 0.332, -0.022 ± 0.033, and -5.81 ± 1.61 diopters, respectively. No significant difference was observed in preoperative (P ≥ .226) or intraoperative parameters (P ≥ .452) between both groups, except residual stromal thickness (P < .001). The UCVA, manifest refraction spherical equivalent, and central corneal thickness stabilized by 1 week, while the thinnest corneal thickness stabilized by 3 months postoperatively. There was no significant difference between both groups for any parameter during all follow-up visits (P ≥ .132) except the 3-month safety index, which was better in the sub-Bowman keratomileusis group (P = .007). Soft opaque bubble layer was noted intraoperatively in 12 cases (7, 100-μm group; 5, 120-μm group; P = .577). No postoperative complications were observed. Our study did not find any differences in the visual and refractive outcomes between femtosecond-assisted sub-Bowman keratomileusis and LASIK. Both surgeries resulted in quick visual recovery as early as 1 week postoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Occurrence of refractive errors among students who before the age of two grew up under the influence of light emitted by incandescent or fluorescent lamps.

    PubMed

    Czepita, Damian; Gosławski, Wojciech; Mojsa, Artur

    2005-01-01

    The aim of the study was to determine whether the development of refractive errors could be associated with exposure to light emitted by incandescent or fluorescent lamps. 3636 students were examined (1638 boys and 1998 girls, aged 6-18 years, mean age 12.1, SD 3.4). The examination included skiascopy with cycloplegia. Myopia was defined as refractive error < or = -0.5 D, hyperopia as refractive error > or = +1.5 D, astigmatism as refractive error > 0.5 DC. Anisometropia was diagnosed when the difference in the refraction of both eyes was > 1.0 D. The parents of all the students examined completed a questionnaire on the child's light exposure before the age oftwo. Data were analyzed statistically with the chi2 test. P values of less than 0.05 were considered statistically significant. It was observed that sleeping until the age of two in a room with a light turned on is associated with an increase in the occurrence of anisometropia (p < 0.02) as well as with a reduction in the prevalence of emmetropia (p < 0.05). It was also found that light emitted by fluorescent lamps leads to more frequent occurrence of astigmatism (p < 0.01).

  2. Refractive errors in a Brazilian population: age and sex distribution.

    PubMed

    Ferraz, Fabio H; Corrente, José E; Opromolla, Paula; Padovani, Carlos Roberto; Schellini, Silvana A

    2015-01-01

    To determine the prevalence of refractive errors and their distribution according to age and sex in a Brazilian population. This population-based cross-sectional study involved 7654 Brazilian inhabitants of nine municipalities of Sao Paulo State, Brazil, between March 2004 and July 2005. Participants aged >1 year were selected using a random, stratified, household cluster sampling technique, excluding individuals with previous refractive or cataract surgery. Myopia was defined as spherical equivalent (SE) ≤-0.5D, high myopia as SE ≤-3.0D, hyperopia as SE ≥+0.5D, high hyperopia as SE ≥+3D, astigmatism as ≤-0.5DC and anisometropia as ≥1.0D difference between eyes. Age, sex, complaints and a comprehensive eye examination including cycloplegic refraction test were collected and analysed using descriptive analysis, univariate and multivariate methods. The prevalence of astigmatism was 59.7%, hyperopia 33.8% and myopia was 25.3%. Astigmatism had a progressive increase with age. With-the-rule (WTR) axes of astigmatism were more frequently observed in the young participants and the against-the-rule (ATR) axes were more frequent in the older subjects. The onset of myopia occurred more frequently between the 2nd and 3rd decades of life. Anisometropia showed a prevalence of 13.2% (95% CI 12.4-13.9; p < 0.001). There was an association between age and all types of refractive error and hyperopia was also associated with sex. Hyperopia was associated with WTR axes (odds ratio 0.73; 95% CI: 0.6-0.8; p < 0.001) and myopia with ATR axes (odds ratio 0.66; 95% CI: 0.6-0.8; p < 0.001). Astigmatism was the most prevalent refractive error in a Brazilian population. There was a strong relationship between age and all refractive errors and between hyperopia and sex. WTR astigmatism was more frequently associated with hyperopia and ATR astigmatism with myopia. The vast majority of participants had low-grade refractive error, which favours planning aimed at correction of refractive error in the population. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  3. Prevalence of refractive error in malay primary school children in suburban area of Kota Bharu, Kelantan, Malaysia.

    PubMed

    Hashim, Syaratul-Emma; Tan, Hui-Ken; Wan-Hazabbah, W H; Ibrahim, Mohtar

    2008-11-01

    Refractive error remains one of the primary causes of visual impairment in children worldwide, and the prevalence of refractive error varies widely. The objective of this study was to determine the prevalence of refractive error and study the possible associated factors inducing refractive error among primary school children of Malay ethnicity in the suburban area of Kota Bharu, Kelantan, Malaysia. A school-based cross-sectional study was performed from January to July 2006 by random selection on Standard 1 to Standard 6 students of 10 primary schools in the Kota Bharu district. Visual acuity assessment was measured using logMAR ETDRS chart. Positive predictive value of uncorrected visual acuity equal or worse than 20/40, was used as a cut-off point for further evaluation by automated refraction and retinoscopic refraction. A total of 840 students were enumerated but only 705 were examined. The prevalence of uncorrected visual impairment was seen in 54 (7.7%) children. The main cause of the uncorrected visual impairment was refractive error which contributed to 90.7% of the total, and with 7.0% prevalence for the studied population. Myopia is the most common type of refractive error among children aged 6 to 12 years with prevalence of 5.4%, followed by hyperopia at 1.0% and astigmatism at 0.6%. A significant positive correlation was noted between myopia development with increasing age (P <0.005), more hours spent on reading books (P <0.005) and background history of siblings with glasses (P <0.005) and whose parents are of higher educational level (P <0.005). Malays in suburban Kelantan (5.4%) have the lowest prevalence of myopia compared with Malays in the metropolitan cities of Kuala Lumpur (9.2%) and Singapore (22.1%). The ethnicity-specific prevalence rate of myopia was the lowest among Malays in Kota Bharu, followed by Kuala Lumpur, and is the highest among Singaporean Malays. Better socio-economic factors could have contributed to higher myopia rates in the cities, since the genetic background of these ethnic Malays are similar.

  4. The U.S. Air Force Photorefractive Keratectomy (PRK) Study: Evaluation of Residual Refractive Error and High- and Low-Contrast Visual Acuity

    DTIC Science & Technology

    2006-07-01

    values for statistical analyses in terms of Snellen equivalent VA (Ref 44) and lines gained vs . lost after PRK . The Snellen VA values shown in the...AFRL-SA-BR-TR-2010-0011 THE U.S. AIR FORCE PHOTOREFRACTIVE KERATECTOMY ( PRK ) STUDY: Evaluation of Residual Refractive Error and High...July 2006 4. TITLE AND SUBTITLE THE U.S. AIR FORCE PHOTOREFRACTIVE KERATECTOMY ( PRK ) STUDY: Evaluation of Residual Refractive Error and High- and

  5. The Refractive Error of Professional Baseball Players.

    PubMed

    Laby, Daniel M; Kirschen, David G

    2017-05-01

    High levels of visual acuity are required to hit a baseball effectively. Research has shown that any decrease in vision is likely caused by low-order optical aberrations. This study is designed to validate the SVOne autorefractor, and describe the amount and type, of low-order optical aberrations present in a large cohort of professional baseball players. A retrospective chart review on the 608 Major League Baseball players evaluated during the 2016 Spring Training Season was performed. Results for a subset of players who had both manifest refraction as well as autorefraction were calculated. Subsequently, after determining the accuracy of the autorefraction system in this population, refractive results for the entire population were determined. There was a borderline statistically significant difference in mean spherical refractive error (M) between the manifest refraction and the SVOne auto refraction (-0.273D in the manifest refraction method vs. -0.503D in the SVOne method, P = .06) in the subset of athletes who underwent both tests. Additionally, there was no difference in the J0 or J45 cylindrical component vectors for each method. For the entire eligible population, the SVOne autorefraction system found a mean spherical refractive error (M) of -0.228D, a J0 value of -0.013D, and a J45 value of -0.040D. These data suggest that the SVOne autorefraction system is generally able to measure the refractive error in the baseball population. The system was slightly biased, often reporting more myopia in myopic subjects. Thus, careful evaluation of the refractive status of these athletes coupled with careful subjective refractive correction for those with less than average vision for baseball is strongly suggested.

  6. Visual impairment in urban school children of low-income families in Kolkata, India.

    PubMed

    Ghosh, Sambuddha; Mukhopadhyay, Udayaditya; Maji, Dipankar; Bhaduri, Gautam

    2012-01-01

    To evaluate pattern of visual impairment in school children from low-income families in Kolkata, India, an institutional cross-sectional study was conducted among 2570 children of 10 primary schools. Ocular examination including refraction was done and pattern of visual impairment and refractive error was studied. The age range was 6-14 years. Refractive error was seen in 14.7%. Only 4 children were already wearing correction. Myopia and hypermetropia was present in 307 (11.9%) and 65 (2.5%) children, respectively. Visual acuity of less than 6/12 in better eye was present in 109 (4.2%) and 5 (0.2%) children pre- and post-correction, respectively. Eighteen children had amblyopia. Although prevalence of refractive error in this group is less compared to school children of all income categories reported from other cities of India, it is more compared to school children of all income categories from the same city. Refractive error mostly remains uncorrected in this group.

  7. Prevalence of refractive errors among schoolchildren in rural central Ethiopia.

    PubMed

    Mehari, Zelalem Addisu; Yimer, Abdirahman Wollie

    2013-01-01

    The aim of the present study was to assess the prevalence of refractive errors and visual impairment among schoolchildren in rural central Ethiopia. A cross-sectional study was conducted from November 2010 to January 2011 among 5,470 schoolchildren from 14 schools, of whom 4,238 (aged 7-18 years) were screened for refractive errors. In all participants, uncorrected vision and best corrected visual acuity were determined and those with a visual acuity of 6/12 or worse, underwent a complete ophthalmic examination to determine the cause of visual impairment. Myopia was defined as a spherical equivalent of -0.50 dioptre (D) or greater in one or both eyes and hyperopia as a spherical equivalent of +2.00 D or greater. A cylindrical power of -0.50 DC (D cylinder) or greater was considered as astigmatism. Chi-square was used to test differences in proportions. Differences were considered to be statistically significant at the five per cent level. Of the 4,238 children, 405 (9.5 per cent) were visually impaired and of these 267 children were diagnosed as having refractive errors, with an overall prevalence of 6.3 per cent, comprised of 6.1 per cent in boys and 6.6 per cent in girls. Myopia is the most prevalent refractive error; accounting for 6.0 per cent, followed by compound myopic astigmatism 1.2 per cent, then simple myopic astigmatism 0.5 per cent, mixed astigmatism 0.26 per cent and finally hyperopia 0.33 per cent. Reasons for visual acuity of 6/12 or worse in the better eye were found to be refractive error (65.9 per cent), corneal problems (12.8 per cent) and amblyopia (9.6 per cent). The prevalence of manifest strabismus in the study group was 1.1 per cent (n = 45). The study concluded that uncorrected refractive error is a common cause of visual impairment among schoolchildren in rural central Ethiopia. This indicates the need for regular school-screening programs that provide glasses at low cost or free of charge for those who have refractive errors. © 2012 The Authors; Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  8. Reducing visual deficits caused by refractive errors in school and preschool children: results of a pilot school program in the Andean region of Apurimac, Peru

    PubMed Central

    Latorre-Arteaga, Sergio; Gil-González, Diana; Enciso, Olga; Phelan, Aoife; García-Muñoz, Ángel; Kohler, Johannes

    2014-01-01

    Background Refractive error is defined as the inability of the eye to bring parallel rays of light into focus on the retina, resulting in nearsightedness (myopia), farsightedness (Hyperopia) or astigmatism. Uncorrected refractive error in children is associated with increased morbidity and reduced educational opportunities. Vision screening (VS) is a method for identifying children with visual impairment or eye conditions likely to lead to visual impairment. Objective To analyze the utility of vision screening conducted by teachers and to contribute to a better estimation of the prevalence of childhood refractive errors in Apurimac, Peru. Design A pilot vision screening program in preschool (Group I) and elementary school children (Group II) was conducted with the participation of 26 trained teachers. Children whose visual acuity was<6/9 [20/30] (Group I) and≤6/9 (Group II) in one or both eyes, measured with the Snellen Tumbling E chart at 6 m, were referred for a comprehensive eye exam. Specificity and positive predictive value to detect refractive error were calculated against clinical examination. Program assessment with participants was conducted to evaluate outcomes and procedures. Results A total sample of 364 children aged 3–11 were screened; 45 children were examined at Centro Oftalmológico Monseñor Enrique Pelach (COMEP) Eye Hospital. Prevalence of refractive error was 6.2% (Group I) and 6.9% (Group II); specificity of teacher vision screening was 95.8% and 93.0%, while positive predictive value was 59.1% and 47.8% for each group, respectively. Aspects highlighted to improve the program included extending training, increasing parental involvement, and helping referred children to attend the hospital. Conclusion Prevalence of refractive error in children is significant in the region. Vision screening performed by trained teachers is a valid intervention for early detection of refractive error, including screening of preschool children. Program sustainability and improvements in education and quality of life resulting from childhood vision screening require further research. PMID:24560253

  9. A variational regularization of Abel transform for GPS radio occultation

    NASA Astrophysics Data System (ADS)

    Wee, Tae-Kwon

    2018-04-01

    In the Global Positioning System (GPS) radio occultation (RO) technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI) is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical lower troposphere. An alternative to AI is the numerical inversion of the forward Abel transform, which does not incur the integration of error-possessing measurement and thus precludes the error propagation. The variational regularization (VR) proposed in this study approximates the inversion of the forward Abel transform by an optimization problem in which the regularized solution describes the measurement as closely as possible within the measurement's considered accuracy. The optimization problem is then solved iteratively by means of the adjoint technique. VR is formulated with error covariance matrices, which permit a rigorous incorporation of prior information on measurement error characteristics and the solution's desired behavior into the regularization. VR holds the control variable in the measurement space to take advantage of the posterior height determination and to negate the measurement error due to the mismodeling of the refractional radius. The advantages of having the solution and the measurement in the same space are elaborated using a purposely corrupted synthetic sounding with a known true solution. The competency of VR relative to AI is validated with a large number of actual RO soundings. The comparison to nearby radiosonde observations shows that VR attains considerably smaller random and systematic errors compared to AI. A noteworthy finding is that in the heights and areas that the measurement bias is supposedly small, VR follows AI very closely in the mean refractivity deserting the first guess. In the lowest few kilometers that AI produces large negative refractivity bias, VR reduces the refractivity bias substantially with the aid of the background, which in this study is the operational forecasts of the European Centre for Medium-Range Weather Forecasts (ECMWF). It is concluded based on the results presented in this study that VR offers a definite advantage over AI in the quality of refractivity.

  10. Femtosecond Laser-assisted Arcuate Keratotomy Versus Toric IOL Implantation for Correcting Astigmatism.

    PubMed

    Yoo, Aeri; Yun, Samyoung; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon

    2015-09-01

    To evaluate the clinical efficacy and safety of femtosecond laser-assisted arcuate keratotomy (FS-AK) versus toric intraocular lens (IOL) implantation for correcting astigmatism in patients with cataract. A retrospective chart review was performed. All patients had senile cataracts with corneal astigmatism (range: +1.00 to +3.00 diopters [D]) before cataract surgery. Twenty-five patients agreed to undergo toric IOL implantation (the toric IOL group). Twenty-three patients did not agree to undergo toric IOL implantation despite astigmatism; however, these patients were not satisfied with their remaining astigmatism following cataract surgery and requested astigmatism correction using FS-AK (the FS-AK group). Visual acuity and intraocular pressure were evaluated, and automated refraction, keratometry, and slit-lamp examinations were performed at 1 day, 1 week, 1 month, and 5 months after surgery. Refractive astigmatism decreased in both groups. The mean preoperative and postoperative refractive cylinders were 1.71 ± 1.15 and 0.78 ± 1.06 D, respectively, in the FS-AK group (P < .001) and 1.67 ± 0.13 and 0.83 ± 0.097 D, respectively, in the toric IOL group (P < .001). There were no statistically significant differences between groups at any time during the follow-up period. FS-AK is a fast, customizable, adjustable, precise, and safe procedure for reducing refractive errors in patients with residual astigmatism after cataract surgery. The results of this procedure are comparable to the toric IOL. Copyright 2015, SLACK Incorporated.

  11. Etiology and outcomes of secondary surgical intervention for dissatisfied patients after pseudophakic monovision.

    PubMed

    Kato, Sayaka; Ito, Misae; Shimizu, Kimiya; Kamiya, Kazutaka

    2017-05-18

    To evaluate the etiology and the clinical outcomes of secondary surgical interventions for dissatisfied patients after pseudophakic monovision. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. Retrospective case series. This study comprised 12 eyes in 12 patients (age 66.2 ± 5.6 years) who underwent photorefractive keratectomy (PRK) enhancement to improve their dissatisfaction after pseudophakic monovision. We quantitatively assessed the visual and refractive outcomes and the subjective satisfaction measured using a visual analog scale, that ranged from 0 (very dissatisfied) to 10 (very satisfied), before and 3 months after PRK enhancement. Six (50%) of the 12 patients were dissatisfied with their various distance visions because of a large amount of anisometropia (≥2.50 D). Two (16.7%) were dissatisfied with their distance vision after conventional monovision because of residual cylindrical errors (≥0.75 D) in the dominant eye. Three (25%) was an unknown origin. The remaining one of the 12 patients was dissatisfied due to the unadaptability to crossed monovision. Eleven (91.7%) eyes were within ±0.5 D of the targeted correction after PRK enhancement. The overall satisfaction score was significantly improved, from 3.7 ± 2.4 (range 0-7) preoperatively to 6.0 ± 2.4 (range 2-9) postoperatively (p = 0.02). No vision-threatening complications were seen throughout the observation period. PRK enhancement was effective with predictable refractive results and thus improved patient satisfaction for dissatisfied patients after pseudophakic monovision. These findings also suggest that the accurate correction of refractive errors plays a key role in successful pseudophakic monovision.

  12. Prevalence of Refractive Error among Preschool Children in an Urban Population: The Baltimore Pediatric Eye Disease Study

    PubMed Central

    Giordano, Lydia; Friedman, David S.; Repka, Michael X.; Katz, Joanne; Ibironke, Josephine; Hawes, Patricia; Tielsch, James M.

    2009-01-01

    Purpose To determine the age-specific prevalence of refractive errors in White and African-American preschool children. Design The Baltimore Pediatric Eye Disease Study is a population-based evaluation of the prevalence of ocular disorders in children aged six through 71 months in Baltimore, Maryland, United States. Participants Among 4,132 children identified, 3,990 eligible children (97%) were enrolled and 2,546 children (62%) were examined. Methods Cycloplegic autorefraction was attempted on all children using a Nikon Retinomax K-Plus 2. If a reliable autorefraction could not be obtained after three attempts, cycloplegic streak retinoscopy was performed. Main Outcome Measures Mean spherical equivalent (SE) refractive error, astigmatism, and prevalence of higher refractive errors among African American and White children. Results The mean spherical equivalent (SE) of right eyes was +1.49 diopter (D) (standard deviation (SD) =1.23) in White and +0.71D (SD=1.35) in African-American children (mean difference of 0.78D, 95% CI: 0.67, 0.89). Mean SE refractive error did not decline with age in either group. The prevalence of myopia of 1.00 D or more in the eye with the lesser refractive error was 0.7% in White and 5.5% in African-American children (RR: 8.01 95% confidence interval (CI): 3.70, 17.35). The prevalence of hyperopia of +3D or more in the eye with the lesser refractive error was 8.9% in White and 4.4% in African-American children (relative risk (RR): 0.49, 95% CI: 0.35, 0.68). The prevalence of emmetropia (less than −1.00 D to less than +1.00 D) was 35.6% in Whites and 58.0 % in African-Americans (RR: 1.64, 95% CI: 1.49, 1.80). Based on published prescribing guidelines 5.1% of the children would have benefited from spectacle correction. However, only 1.3% had been previously prescribed correction. Conclusions Significant refractive errors are uncommon in this population of urban preschool children. There was no evidence for a myopic shift over this age range in this cross-sectional study. A small proportion of preschool children would likely benefit from refractive correction, but few have had this prescribed. PMID:19243832

  13. Relationship between lenticular power and refractive error in children with hyperopia.

    PubMed

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia.

  14. Gender differences in a refractive surgery population of civilian aviators : final report.

    DOT National Transportation Integrated Search

    2000-07-01

    INTRODUCTION. Refractive surgical procedures performed in the United States have increased in recent years and : continued growth is projected. Postoperative side effects can affect the quality of vision and may be unacceptable in a : cockpit environ...

  15. Gender differences in a refractive surgery population of civilian aviators : final report.

    DOT National Transportation Integrated Search

    2000-07-01

    INTRODUCTION. Refractive surgical procedures performed in the United States have increased in recent years and continued growth is projected. Postoperative side effects can affect the quality of vision and may be unacceptable in a cockpit environment...

  16. Paediatric Refractive Errors in an Eye Clinic in Osogbo, Nigeria.

    PubMed

    Michaeline, Isawumi; Sheriff, Agboola; Bimbo, Ayegoro

    2016-03-01

    Paediatric ophthalmology is an emerging subspecialty in Nigeria and as such there is paucity of data on refractive errors in the country. This study set out to determine the pattern of refractive errors in children attending an eye clinic in South West Nigeria. A descriptive study of 180 consecutive subjects seen over a 2-year period. Presenting complaints, presenting visual acuity (PVA), age and sex were recorded. Clinical examination of the anterior and posterior segments of the eyes, extraocular muscle assessment and refraction were done. The types of refractive errors and their grades were determined. Corrected VA was obtained. Data was analysed using descriptive statistics in proportions, chi square with p value <0.05. The age range of subjects was between 3 and 16 years with mean age = 11.7 and SD = 0.51; with males making up 33.9%.The commonest presenting complaint was blurring of distant vision (40%), presenting visual acuity 6/9 (33.9%), normal vision constituted >75.0%, visual impairment20% and low vision 23.3%. Low grade spherical and cylindrical errors occurred most frequently (35.6% and 59.9% respectively). Regular astigmatism was significantly more common, P <0.001. The commonest diagnosis was simple myopic astigmatism (41.1%). Four cases of strabismus were seen. Simple spherical and cylindrical errors were the commonest types of refractive errors seen. Visual impairment and low vision occurred and could be a cause of absenteeism from school. Low-cost spectacle production or dispensing unit and health education are advocated for the prevention of visual impairment in a hospital set-up.

  17. Design and Validation of an Infrared Badal Optometer for Laser Speckle (IBOLS)

    PubMed Central

    Teel, Danielle F. W.; Copland, R. James; Jacobs, Robert J.; Wells, Thad; Neal, Daniel R.; Thibos, Larry N.

    2009-01-01

    Purpose To validate the design of an infrared wavefront aberrometer with a Badal optometer employing the principle of laser speckle generated by a spinning disk and infrared light. The instrument was designed for subjective meridional refraction in infrared light by human patients. Methods Validation employed a model eye with known refractive error determined with an objective infrared wavefront aberrometer. The model eye was used to produce a speckle pattern on an artificial retina with controlled amounts of ametropia introduced with auxiliary ophthalmic lenses. A human observer performed the psychophysical task of observing the speckle pattern (with the aid of a video camera sensitive to infrared radiation) formed on the artificial retina. Refraction was performed by adjusting the vergence of incident light with the Badal optometer to nullify the motion of laser speckle. Validation of the method was performed for different levels of spherical ametropia and for various configurations of an astigmatic model eye. Results Subjective measurements of meridional refractive error over the range −4D to + 4D agreed with astigmatic refractive errors predicted by the power of the model eye in the meridian of motion of the spinning disk. Conclusions Use of a Badal optometer to control laser speckle is a valid method for determining subjective refractive error at infrared wavelengths. Such an instrument will be useful for comparing objective measures of refractive error obtained for the human eye with autorefractors and wavefront aberrometers that employ infrared radiation. PMID:18772719

  18. Pre- and Postcycloplegic Refractions in Children and Adolescents

    PubMed Central

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    Purpose To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. Methods A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Results Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6–78.8) and 54.1% (95%CI 51.6–56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9–3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7–17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Conclusions Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error. PMID:27907165

  19. Pre- and Postcycloplegic Refractions in Children and Adolescents.

    PubMed

    Zhu, Dan; Wang, Yan; Yang, Xianrong; Yang, Dayong; Guo, Kai; Guo, Yuanyuan; Jing, Xinxia; Pan, Chen-Wei

    2016-01-01

    To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refractive error were measured using an auto-refractor. For cycloplegic refraction, one drop of topical 1.0% cyclopentolate was administered to each eye twice with a 5-minute interval and a third drop was administered 15 minutes after the second drop if the pupil size was less than 6 mm or if the pupillary light reflex was still present. Two drops of cyclopentolate were found to be sufficient in 59% of the study participants while the other 41% need an additional drop. The prevalence of myopia was 89.5% in participants aged over 12 years and 68.6% in those aged 12 years or younger (P<0.001). When myopia was defined as spherical equivalent (SE) of less than -0.5 diopter (D), the prevalence estimates were 76.7% (95% confidence interval [CI] 74.6-78.8) and 54.1% (95%CI 51.6-56.6) before and after cycloplegic refraction, respectively. When hyperopia was defined as SE of more than 0.5D, the prevalence was only 2.8% (95%CI 1.9-3.6) before cycloplegic refraction while it was 15.5% (95%CI 13.7-17.3) after cycloplegic refraction. Increased difference between cycloplegic and non-cycloplegic refractive error was associated with decreased intraocular pressures (P = 0.01). Lack of cycloplegia in refractive error measurement was associated with significant misclassifications in both myopia and hyperopia among Chinese children and adolescents. Decreased intraocular pressure was related to a greater difference between cycloplegic and non-cycloplegic refractive error.

  20. [Intraoperative Measurement of Refraction with a Hand-Held Autorefractometer].

    PubMed

    Gesser, C; Küper, T; Richard, G; Hassenstein, A

    2015-07-01

    The aim of this study was to evaluate an intraoperative measurement of objective refraction with a hand-held retinomax instrument. At the end of cataract surgery objective refraction in a lying position was measured with a retinomax instrument. On the first postoperative day the same measurement was performed with a retinomax and a standard autorefractometer. To evaluate the differences between measurements, the spherical equivalent (SE) and Jackson's cross cylinder at 0° (J0) and 45° (J45) was used. 103 eyes were included. 95 of them had normal cataract surgery. Differences between retinomax at the operative day and the standard autorefractometer were 0.68 ± 2.58 D in SE, 0.05 ± 1.4D in J0 and 0.05 ± 1.4D in J45. There were no statistically significant differences between the groups. Intraoperative measurement of the refraction with a retinomax can predict the postoperative refraction. Nevertheless, in a few patients great differences may occur. Georg Thieme Verlag KG Stuttgart · New York.

  1. Linkage Analysis of Quantitative Refraction and Refractive Errors in the Beaver Dam Eye Study

    PubMed Central

    Duggal, Priya; Lee, Kristine E.; Cheng, Ching-Yu; Klein, Ronald; Bailey-Wilson, Joan E.; Klein, Barbara E. K.

    2011-01-01

    Purpose. Refraction, as measured by spherical equivalent, is the need for an external lens to focus images on the retina. While genetic factors play an important role in the development of refractive errors, few susceptibility genes have been identified. However, several regions of linkage have been reported for myopia (2q, 4q, 7q, 12q, 17q, 18p, 22q, and Xq) and for quantitative refraction (1p, 3q, 4q, 7p, 8p, and 11p). To replicate previously identified linkage peaks and to identify novel loci that influence quantitative refraction and refractive errors, linkage analysis of spherical equivalent, myopia, and hyperopia in the Beaver Dam Eye Study was performed. Methods. Nonparametric, sibling-pair, genome-wide linkage analyses of refraction (spherical equivalent adjusted for age, education, and nuclear sclerosis), myopia and hyperopia in 834 sibling pairs within 486 extended pedigrees were performed. Results. Suggestive evidence of linkage was found for hyperopia on chromosome 3, region q26 (empiric P = 5.34 × 10−4), a region that had shown significant genome-wide evidence of linkage to refraction and some evidence of linkage to hyperopia. In addition, the analysis replicated previously reported genome-wide significant linkages to 22q11 of adjusted refraction and myopia (empiric P = 4.43 × 10−3 and 1.48 × 10−3, respectively) and to 7p15 of refraction (empiric P = 9.43 × 10−4). Evidence was also found of linkage to refraction on 7q36 (empiric P = 2.32 × 10−3), a region previously linked to high myopia. Conclusions. The findings provide further evidence that genes controlling refractive errors are located on 3q26, 7p15, 7p36, and 22q11. PMID:21571680

  2. Manual limbal markings versus iris-registration software for correction of myopic astigmatism by laser in situ keratomileusis.

    PubMed

    Shen, Elizabeth P; Chen, Wei-Li; Hu, Fung-Rong

    2010-03-01

    To compare the efficacy and safety of manual limbal markings and wavefront-guided treatment with iris-registration software in laser in situ keratomileusis (LASIK) for myopic astigmatism. National Taiwan University Hospital, Taipei, Taiwan. Eyes with myopic astigmatism had LASIK with a Technolas 217z laser. Eyes in the limbal-marking group had conventional LASIK (PlanoScan or Zyoptix tissue-saving algorithm) with manual cyclotorsional-error adjustments according to 2 limbal marks. Eyes in the iris-registration group had wavefront-guided ablation (Zyoptix) in which cyclotorsional errors were automatically detected and adjusted. Refraction, corneal topography, and visual acuity data were compared between groups. Vector analysis was by the Alpins method. The mean preoperative spherical equivalent (SE) was -6.64 diopters (D) +/- 1.99 (SD) in the limbal-marking group and -6.72 +/- 1.86 D in the iris-registration group (P = .92). At 6 months, the mean SE was -0.42 +/- 0.63 D and -0.47 +/- 0.62 D, respectively (P = .08). There was no statistically significant difference between groups in the astigmatism correction, success, or flattening index values using 6-month postoperative refractive data. The angle of error was within +/-10 degrees in 73% of eyes in the limbal-marking group and 75% of eyes in the iris-registration group. Manual limbal markings and iris-registration software were equally effective and safe in LASIK for myopic astigmatism, showing that checking cyclotorsion by manual limbal markings is a safe alternative when automated systems are not available. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Minimizing the IOL power error induced by keratometric power.

    PubMed

    Camps, Vicente J; Piñero, David P; de Fez, Dolores; Mateo, Verónica

    2013-07-01

    To evaluate theoretically in normal eyes the influence on IOL power (PIOL) calculation of the use of a keratometric index (nk) and to analyze and validate preliminarily the use of an adjusted keratometric index (nkadj) in the IOL power calculation (PIOLadj). A model of variable keratometric index (nkadj) for corneal power calculation (Pc) was used for IOL power calculation (named PIOLadj). Theoretical differences (ΔPIOL) between the new proposed formula (PIOLadj) and which is obtained through Gaussian optics ((Equation is included in full-text article.)) were determined using Gullstrand and Le Grand eye models. The proposed new formula for IOL power calculation (PIOLadj) was prevalidated clinically in 81 eyes of 81 candidates for corneal refractive surgery and compared with Haigis, HofferQ, Holladay, and SRK/T formulas. A theoretical PIOL underestimation greater than 0.5 diopters was present in most of the cases when nk = 1.3375 was used. If nkadj was used for Pc calculation, a maximal calculated error in ΔPIOL of ±0.5 diopters at corneal vertex in most cases was observed independently from the eye model, r1c, and the desired postoperative refraction. The use of nkadj in IOL power calculation (PIOLadj) could be valid with effective lens position optimization nondependent of the corneal power. The use of a single value of nk for Pc calculation can lead to significant errors in PIOL calculation that may explain some IOL power overestimations with conventional formulas. These inaccuracies can be minimized by using the new PIOLadj based on the algorithm of nkadj.

  4. Refractive errors in low-income preschoolers.

    PubMed

    Brody, Barbara L; Roch-Levecq, Anne-Catherine; Klonoff-Cohen, Hillary S; Brown, Stuart I

    2007-01-01

    To estimate the overall prevalence of refractive errors in a study population of low-income preschoolers in San Diego County. The study sample included 507 preschool children selected from a study population of all 3-5 year-old children in Head Start and San Diego Unified School District preschools (74% Latino). The sample was examined by optometrists in the mobile clinic of the University of California, San Diego, Department of Ophthalmology with retinoscopy under cycloplegia to assess the presence of refractive errors defined as myopia >or=2D in 3-4 year-olds and >or=1D in > 4 year-olds; hyperopia >or=4D in 3-4 year-olds and >or=3D in > 4 year-olds; and astigmatism >or=1.75D in 3-4 year-olds and >or=1.5D in > 4 year-olds. Anisometropia was defined as >or=1.25D difference between the eyes. Emmetropia was defined as refractive errors below these levels. A total of 16% (n = 81 children) (95% confidence interval: 15.4-16.5) met study definitions of refractive errors in at least one eye. Myopia was found in 3%, (OD Mean Sphere = 2.4D); hyperopia in 7.5% (OD Mean Sphere = 3.8D); astigmatism in 5.5% (OD Mean Cylinder = 2.3D); and 84% were emmetropic (OD Mean Sphere = 1.3D). Hyperopia and astigmatism were the most frequent refractive errors in this sample of low-income preschoolers, most of whom were Latino.

  5. Epithelial ingrowth following laser in situ keratomileusis (LASIK): prevalence, risk factors, management and visual outcomes

    PubMed Central

    Srinivasan, Sathish; Danjoux, Jean-Pierre

    2018-01-01

    The number of laser in situ keratomileusis (LASIK) procedures is continuing to rise. Since its first application for correcting simple refractive errors over 25 years ago, the role of LASIK has extended to treat other conditions, including postkeratoplasty astigmatism/ametropia, postcataract surgery refractive error and presbyopia, among others. The long-term effectiveness, predictability and safety have been well established by many large studies. However, due to the creation of a potential interface between the flap and the underlying stroma, interface complications such as infectious keratitis, diffuse lamellar keratitis and epithelial ingrowth may occur. Post-LASIK epithelial ingrowth (PLEI) is an uncommon complication that usually arises during the early postoperative period. The reported incidence of PLEI ranged from 0%–3.9% in primary treatment to 10%–20% in retreatment cases. It can cause a wide spectrum of clinical presentations, ranging from asymptomatic interface changes to severe visual impairment and flap melt requiring keratoplasty. PLEI can usually be treated with mechanical debridement of the affected interface; however, additional interventions, such as alcohol, mitomycin C, fibrin glue, ocular hydrogel sealant, neodymium:yttriumaluminum garnet laser and amniotic membrane graft, may be required for recurrent or refractory cases. The aims of this review are to determine the prevalence and risk factors of PLEI; to describe its pathogenesis and clinical features and to summarise the therapeutic armamentarium and the visual outcome of PLEI. PMID:29657982

  6. Epithelial ingrowth following laser in situ keratomileusis (LASIK): prevalence, risk factors, management and visual outcomes.

    PubMed

    Ting, Darren Shu Jeng; Srinivasan, Sathish; Danjoux, Jean-Pierre

    2018-01-01

    The number of laser in situ keratomileusis (LASIK) procedures is continuing to rise. Since its first application for correcting simple refractive errors over 25 years ago, the role of LASIK has extended to treat other conditions, including postkeratoplasty astigmatism/ametropia, postcataract surgery refractive error and presbyopia, among others. The long-term effectiveness, predictability and safety have been well established by many large studies. However, due to the creation of a potential interface between the flap and the underlying stroma, interface complications such as infectious keratitis, diffuse lamellar keratitis and epithelial ingrowth may occur. Post-LASIK epithelial ingrowth (PLEI) is an uncommon complication that usually arises during the early postoperative period. The reported incidence of PLEI ranged from 0%-3.9% in primary treatment to 10%-20% in retreatment cases. It can cause a wide spectrum of clinical presentations, ranging from asymptomatic interface changes to severe visual impairment and flap melt requiring keratoplasty. PLEI can usually be treated with mechanical debridement of the affected interface; however, additional interventions, such as alcohol, mitomycin C, fibrin glue, ocular hydrogel sealant, neodymium:yttriumaluminum garnet laser and amniotic membrane graft, may be required for recurrent or refractory cases. The aims of this review are to determine the prevalence and risk factors of PLEI; to describe its pathogenesis and clinical features and to summarise the therapeutic armamentarium and the visual outcome of PLEI.

  7. Ketamine-xylazine anesthesia causes hyperopic refractive shift in mice

    PubMed Central

    Tkatchenko, Tatiana V.; Tkatchenko, Andrei V.

    2010-01-01

    Mice have increasingly been used as a model for studies of myopia. The key to successful use of mice for myopia research is the ability to obtain accurate measurements of refractive status of their eyes. In order to obtain accurate measurements of refractive errors in mice, the refraction needs to be performed along the optical axis of the eye. This represents a particular challenge, because mice are very difficult to immobilize. Recently, ketamine-xylazine anesthesia has been used to immobilize mice before measuring refractive errors, in combination with tropicamide ophthalmic solution to induce mydriasis. Although these drugs have increasingly been used while refracting mice, their effects on the refractive state of the mouse eye have not yet been investigated. Therefore, we have analyzed the effects of tropicamide eye drops and ketamine-xylazine anesthesia on refraction in P40 C57BL/6J mice. We have also explored two alternative methods to immobilize mice, i.e. the use of a restraining platform and pentobarbital anesthesia. We found that tropicamide caused a very small, but statistically significant, hyperopic shift in refraction. Pentobarbital did not have any substantial effect on refractive status, whereas ketamine-xylazine caused a large and highly significant hyperopic shift in refraction. We also found that the use of a restraining platform represents good alternative for immobilization of mice prior to refraction. Thus, our data suggest that ketamine-xylazine anesthesia should be avoided in studies of refractive development in mice and underscore the importance of providing appropriate experimental conditions when measuring refractive errors in mice. PMID:20813132

  8. Decision support system for determining the contact lens for refractive errors patients with classification ID3

    NASA Astrophysics Data System (ADS)

    Situmorang, B. H.; Setiawan, M. P.; Tosida, E. T.

    2017-01-01

    Refractive errors are abnormalities of the refraction of light so that the shadows do not focus precisely on the retina resulting in blurred vision [1]. Refractive errors causing the patient should wear glasses or contact lenses in order eyesight returned to normal. The use of glasses or contact lenses in a person will be different from others, it is influenced by patient age, the amount of tear production, vision prescription, and astigmatic. Because the eye is one organ of the human body is very important to see, then the accuracy in determining glasses or contact lenses which will be used is required. This research aims to develop a decision support system that can produce output on the right contact lenses for refractive errors patients with a value of 100% accuracy. Iterative Dichotomize Three (ID3) classification methods will generate gain and entropy values of attributes that include code sample data, age of the patient, astigmatic, the ratio of tear production, vision prescription, and classes that will affect the outcome of the decision tree. The eye specialist test result for the training data obtained the accuracy rate of 96.7% and an error rate of 3.3%, the result test using confusion matrix obtained the accuracy rate of 96.1% and an error rate of 3.1%; for the data testing obtained accuracy rate of 100% and an error rate of 0.

  9. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    PubMed

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  10. Changes in astigmatism and corneal higher-order aberrations after phacoemulsification with toric intraocular lens implantation for mild keratoconus with cataract.

    PubMed

    Kamiya, Kazutaka; Shimizu, Kimiya; Miyake, Toshiyuki

    2016-07-01

    To assess the changes in astigmatism and higher-order aberrations (HOAs) after toric intraocular lens (IOL) implantation for mild non-progressive keratoconus with cataract. We prospectively examined 19 eyes of 19 consecutive keratoconic patients (mean age ± standard deviation, 63.1 ± 9.1 years) who underwent phacoemulsification with toric IOL implantation. We determined uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, corneal astigmatism, corneal HOAs and astigmatic axis rotation both preoperatively and 3 months postoperatively. Logarithm of the minimal angle of resolution (logMAR) UDVA was significantly improved from 1.14 ± 0.50 preoperatively to 0.46 ± 0.33 postoperatively (Wilcoxon signed-rank test, p < 0.001). LogMAR CDVA was also significantly improved from 0.27 ± 0.45 preoperatively to -0.01 ± 0.09 postoperatively (p < 0.001). In 5 of 6 eyes in which the target refraction was emmetropia, postoperative UDVA was better than 20/32. The achieved spherical equivalent correction was within ±0.5 diopters (D) of the targeted correction in 13 (68 %) eyes and 1.0 in 18 (95 %) eyes. The refractive astigmatism was significantly decreased from -1.92 ± 1.73 D preoperatively to -0.70 ± 0.60 D postoperatively (p = 0.006). The corneal astigmatism changed from 2.89 ± 1.30 D preoperatively to 2.98 ± 1.09 D postoperatively (p = 0.492), which was not statistically significant. The corneal HOAs for a 4-mm pupil was changed from 0.47 ± 0.23 µm preoperatively to 0.52 ± 0.26 µm postoperatively (p = 0.211), which was not statistically significant. According to our experience, toric IOL implantation for mild keratoconic patients having rigid gas-permeable lens intolerance appears to be effective for reducing refractive astigmatism without a significant induction of corneal HOAs.

  11. Outcomes of presbyopia-correcting intraocular lenses after laser in situ keratomileusis.

    PubMed

    Chow, Sharon S W; Chan, Tommy C Y; Ng, Alex L K; Kwok, Alvin K H

    2018-03-28

    Laser in situ keratomileusis (LASIK) is the most common refractive surgery in young patients, which aims at providing a clear distance vision without the use of spectacles. With time, these patients develop symptomatic cataract, which affects activities of daily living, and to improve visual acuity, intraocular lens (IOL) implantation can be considered. In post-myopic LASIK patients, to allow continuation of spectacle independence, the implantation of presbyopia-correcting IOLs is a suitable option. The purpose of this retrospective case series is to report the visual outcome and quality in post-myopic LASIK eyes after the implantation of AT LISA tri839MP IOL. Twenty eyes of 13 patients with history of myopic LASIK within 20 years underwent phacoemulsification by one single surgeon. All eyes were implanted with AT LISA tri839PMP IOL, and their outcomes were evaluated at 6 months postoperation. The mean postoperative uncorrected distance visual acuity (VA) is 0.28 ± 0.29, while the corrected distance VA is 0.06 ± 0.14. The mean postoperative uncorrected near VA is 0.02 ± 0.05, while the corrected near VA is 0.01 ± 0.02. The mean postoperative manifest refraction spherical equivalent (SE) is - 0.92 ± 0.76D. There is a statistically significant difference between the preoperative and postoperative refraction (p = 0.02), which shows a postoperative myopic shift. There is also a statistically significant difference between the mean targeted SE and postoperative manifest refraction SE (p = 0.00). Only one out of 20 eyes (5%) reported halo and glare symptoms. Ten out of 20 eyes (50%) are able to achieve spectacles independence. In conclusion, in post-myopic LASIK eyes, AT LISA tri839MP provides a good visual outcome at both near and distance, but is more predictable at near than at distance. There is a myopic shift in the postoperative SE. Visual quality is satisfactory and has not been exacerbated. Most patients can remain to be spectacles free at all distances.

  12. Refractive error in school children in an urban and rural setting in Cambodia.

    PubMed

    Gao, Zoe; Meng, Ngy; Muecke, James; Chan, Weng Onn; Piseth, Horm; Kong, Aimee; Jnguyenphamhh, Theresa; Dehghan, Yalda; Selva, Dinesh; Casson, Robert; Ang, Kim

    2012-02-01

    To assess the prevalence of refractive error in schoolchildren aged 12-14 years in urban and rural settings in Cambodia's Phnom Penh and Kandal provinces. Ten schools from Phnom Penh Province and 26 schools from Kandal Province were randomly selected and surveyed in October 2010. Children were examined by teams of Australian and Cambodian optometrists, ophthalmic nurses and ophthalmologists who performed visual acuity (VA) testing and cycloplegic refraction. A total of 5527 children were included in the study. The prevalence of uncorrected, presenting and best-corrected VA ≤ 6/12 in the better eye were 2.48% (95% confidence interval [CI] 2.02-2.83%), 1.90% (95% CI 1.52-2.24%) and 0.36% (95% CI 0.20-0.52%), respectively; 43 children presented with glasses whilst a total of 315 glasses were dispensed. The total prevalence of refractive error was 6.57% (95% CI 5.91-7.22%), but there was a significant difference between urban (13.7%, 95% CI 12.2-15.2%) and rural (2.5%, 95% CI 2.03-3.07%) schools (P < 0.0001). Refractive error accounted for 91.2% of visually impaired eyes, cataract for 1.7%, and other causes for 7.1%. Myopia (spherical equivalent ≤ -0.50 diopters [D] in either eye) was associated with increased age, female gender and urban schooling. The prevalence of refractive error was significantly higher in urban Phnom Penh schools than rural schools in Kandal Province. The prevalence of refractive error, particularly myopia was relatively low compared to previous reports in Asia. The majority of children did not have appropriate correction with spectacles, highlighting the need for more effective screening and optical intervention.

  13. Frequency and Distribution of Refractive Error in Adult Life: Methodology and Findings of the UK Biobank Study

    PubMed Central

    Cumberland, Phillippa M.; Bao, Yanchun; Hysi, Pirro G.; Foster, Paul J.; Hammond, Christopher J.; Rahi, Jugnoo S.

    2015-01-01

    Purpose To report the methodology and findings of a large scale investigation of burden and distribution of refractive error, from a contemporary and ethnically diverse study of health and disease in adults, in the UK. Methods U K Biobank, a unique contemporary resource for the study of health and disease, recruited more than half a million people aged 40–69 years. A subsample of 107,452 subjects undertook an enhanced ophthalmic examination which provided autorefraction data (a measure of refractive error). Refractive error status was categorised using the mean spherical equivalent refraction measure. Information on socio-demographic factors (age, gender, ethnicity, educational qualifications and accommodation tenure) was reported at the time of recruitment by questionnaire and face-to-face interview. Results Fifty four percent of participants aged 40–69 years had refractive error. Specifically 27% had myopia (4% high myopia), which was more common amongst younger people, those of higher socio-economic status, higher educational attainment, or of White or Chinese ethnicity. The frequency of hypermetropia increased with age (7% at 40–44 years increasing to 46% at 65–69 years), was higher in women and its severity was associated with ethnicity (moderate or high hypermetropia at least 30% less likely in non-White ethnic groups compared to White). Conclusions Refractive error is a significant public health issue for the UK and this study provides contemporary data on adults for planning services, health economic modelling and monitoring of secular trends. Further investigation of risk factors is necessary to inform strategies for prevention. There is scope to do this through the planned longitudinal extension of the UK Biobank study. PMID:26430771

  14. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology

    PubMed Central

    Ouchi, M; Kinoshita, S

    2015-01-01

    Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442

  15. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    PubMed

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  16. Visual and Refractive Outcomes in Manual versus Femtosecond Laser-Assisted Cataract Surgery: A Single-Center Retrospective Cohort Analysis of 1838 Eyes.

    PubMed

    Berk, Thomas A; Schlenker, Matthew B; Campos-Möller, Xavier; Pereira, Austin M; Ahmed, Iqbal Ike K

    2018-03-06

    Femtosecond laser-assisted cataract surgery (FLACS) has emerged as an alternative to manual cataract surgery (MCS) for corneal incision and capsulorhexis creation, as well as nuclear fragmentation. This study compares postoperative refractive and visual outcomes in eyes receiving MCS or FLACS. Single-center, comparative, retrospective cohort analysis. Consecutive eyes receiving FLACS and MCS from July 1, 2012, to July 31, 2015, at a single tertiary care center. Demographic data, ocular history, preoperative measurements and biometry, and postoperative surgical results were retrospectively obtained and statistically analyzed using a generalized linear mixed model adjusting for differences in baseline characteristics and within-patient correlation. A 2-tailed P value <0.05 was considered statistically significant throughout the study. Percentage of eyes achieving absolute error (AE) ≤0.5 diopters (D). Secondary outcomes included percentage of eyes with AE ≤0.25 D and ≤1.0 D, and percentage of distance-targeted eyes achieving uncorrected distance visual acuity (UDVA) of 20/20 or better, 20/25 or better, and 20/30 or better. A total of 883 eyes received MCS and 955 received FLACS among 1089 patients. Some 82.6% of FLACS eyes and 78.8% of MCS eyes had ≤0.5 D of AE at 3 weeks, representing an adjusted odds ratio (OR) of 1.28 (95% confidence interval [CI], 0.98-1.66) of FLACS relative to MCS being within target. Some 97.1% of FLACS and 97.2% of MCS eyes had ≤1.0 D of AE (OR, 0.96; 95% CI, 0.57-1.60) and 49.3% of FLACS and 46.3% of MCS eyes, ≤0.25 D of AE (OR, 1.13; 95% CI, 0.91-1.39). Factors predictive of a favorable refractive outcome included axial length between 22 and 24.8 mm, receiving a toric intraocular lens, less preoperative cylinder, and greater preoperative average keratometry. There was no significant difference in the percentage of patients targeted for distance who achieved UDVA of 20/20 or better (P = 0.30), 20/25 or better (P = 0.06), or 20/30 or better (P = 0.66) vision. Postoperatively, there was no statistically significant difference found between eyes undergoing FLACS and eyes undergoing MCS with respect to refractive and visual outcomes. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Stability of therapeutic retreatment of corneal wavefront customized ablation with the SCHWIND CAM: 4-year data.

    PubMed

    Aslanides, Ioannis M; Kolli, Sai; Padroni, Sara; Padron, Sara; Arba Mosquera, Samuel

    2012-05-01

    To evaluate the long-term outcomes of aspheric corneal wavefront ablation profiles for excimer laser retreatment. Eighteen eyes that had previously undergone LASIK or photorefractive keratectomy (PRK) were retreated with LASIK using the corneal wavefront ablation profile. Custom Ablation Manager (SCHWIND eye-tech-solutions, Kleinostheim, Germany) software and the ESIRIS flying spot excimer laser system (SCHWIND) were used to perform the ablations. Refractive outcomes and wavefront data are reported up to 4 years after retreatment. Pre- and postoperative data were compared with Student t tests and (multivariate) correlation tests. P<.05 was considered statistically significant. A bilinear correlation of various postoperative wavefront aberrations versus planned correction and preoperative aberration was performed. Mean manifest refraction spherical equivalent (MRSE) before retreatment was -0.38±1.85 diopters (D) and -0.09±0.22 D at 6 months and -0.10±0.38 D at 4 years postoperatively. The reduction in MRSE was statistically significant at both postoperative time points (P<.005). Postoperative aberrations were statistically lower (spherical aberration P<.05; coma P<.005; root-mean-square higher order aberration P<.0001) at 4 years postoperatively. Distribution of the postoperative uncorrected distance visual acuity (P<.0001) and corrected distance visual acuity (P<.01) were statistically better than preoperative values. Aspheric corneal wavefront customization with the ESIRIS yields visual, optical, and refractive results comparable to those of other wavefront-guided customized techniques for the correction of myopia and myopic astigmatism. The corneal wavefront customized approach shows its strength in cases where abnormal optical systems are expected. Systematic wavefront customized corneal ablation appears safe and efficacious for retreatment cases. Copyright 2012, SLACK Incorporated.

  18. Refractive errors in patients with newly diagnosed diabetes mellitus.

    PubMed

    Yarbağ, Abdülhekim; Yazar, Hayrullah; Akdoğan, Mehmet; Pekgör, Ahmet; Kaleli, Suleyman

    2015-01-01

    Diabetes mellitus is a complex metabolic disorder that involves the small blood vessels, often causing widespread damage to tissues, including the eyes' optic refractive error. In patients with newly diagnosed diabetes mellitus who have unstable blood glucose levels, refraction may be incorrect. We aimed to investigate refraction in patients who were recently diagnosed with diabetes and treated at our centre. This prospective study was performed from February 2013 to January 2014. Patients were diagnosed with diabetes mellitus using laboratory biochemical tests and clinical examination. Venous fasting plasma glucose (fpg) levels were measured along with refractive errors. Two measurements were taken: initially and after four weeks. The last difference between the initial and end refractive measurements were evaluated. Our patients were 100 males and 30 females who had been newly diagnosed with type II DM. The refractive and fpg levels were measured twice in all patients. The average values of the initial measurements were as follows: fpg level, 415 mg/dl; average refractive value, +2.5 D (Dioptres). The average end of period measurements were fpg, 203 mg/dl; average refractive value, +0.75 D. There is a statistically significant difference between after four weeks measurements with initially measurements of fasting plasma glucose (fpg) levels (p<0.05) and there is a statistically significant relationship between changes in fpg changes with glasses ID (p<0.05) and the disappearance of blurred vision (to be greater than 50% success rate) were statistically significant (p<0.05). Also, were detected upon all these results the absence of any age and sex effects (p>0.05). Refractive error is affected in patients with newly diagnosed diabetes mellitus; therefore, plasma glucose levels should be considered in the selection of glasses.

  19. Effects of light refraction on the accuracy of camera calibration and reconstruction in underwater motion analysis.

    PubMed

    Kwon, Young-Hoo; Casebolt, Jeffrey B

    2006-01-01

    One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water-air interface plane (glass) owing to the density difference. Camera calibration-reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction-induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a through review of: the nature of the refraction-induced image deformation and its behaviour in underwater object-space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration-reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration-reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double-plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction.

  20. Effects of light refraction on the accuracy of camera calibration and reconstruction in underwater motion analysis.

    PubMed

    Kwon, Young-Hoo; Casebolt, Jeffrey B

    2006-07-01

    One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water-air interface plane (glass) owing to the density difference. Camera calibration-reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction-induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a thorough review of: the nature of the refraction-induced image deformation and its behaviour in underwater object-space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration-reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration-reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double-plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction.

  1. Refractive Outcomes of 20 Eyes Undergoing ICL Implantation for Correction of Hyperopic Astigmatism.

    PubMed

    Coskunseven, Efekan; Kavadarli, Isilay; Sahin, Onurcan; Kayhan, Belma; Pallikaris, Ioannis

    2017-09-01

    To analyze 1-week, 1-month, and 12-month postoperative refractive outcomes of eyes that under-went ICL implantation to correct hyperopic astigmatism. The study enrolled 20 eyes of patients with an average age of 32 years (range: 21 to 40 years). The outcomes of spherical and cylindrical refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), vault, and angle parameters were evaluated 1 week, 1 month, and 12 months postoperatively. The preoperative mean UDVA was 0.15 ± 0.11 (decimal) (20/133 Snellen) and increased to 0.74 ± 0.25 (20/27 Snellen) postoperatively, with a change of 0.59 (decimal) (20/33.9 Snellen) (P < .0001), which was statistically significant. The preoperative mean CDVA was 0.74 ± 0.25 (decimal) (20/27 Snellen) and increased to 0.78 ± 0.21 (20/25 Snellen), with a change of 0.03 (decimal) (20/666 Snellen) (P < .052), which was not statistically significant. The mean preoperative sphere was 6.86 ± 1.77 diopters (D) and the mean preoperative cylinder was -1.44 ± 0.88 D. The mean 12-month postoperative sphere decreased to 0.46 ± 0.89 D (P < .001) and cylinder decreased to -0.61 ± 0.46 D (P < .001), with a change of 6.40 D, both of which were statistically significant. The mean 1-month postoperative vault was 0.65 ± 0.13 mm and decreased to 0.613 ± 0.10 mm at 1 year postoperatively, with a change of 0.44 mm (P < .003). The preoperative/12-month and 1-month/12-month trabecular-iris angle (TIA), trabecular-iris space area 500 mm from the scleral spur (TISA500), and angle opening distance 500 mm from the scleral spur (AOD500) values were analyzed nasally, temporally, and inferiorly. All differences were statistically significant between preoperative/12-month analysis. The only differences between 1- and 12-month analysis were on TISA500 inferior (P < .002) and AOD500 nasal (0.031) values. ICL hyperopic toric implantation is a safe method and provides stable refractive outcomes in patients with high hyperopia (up to 10.00 D) and astigmatism (up to 6.00 D). [J Refract Surg. 2017;33(9):604-609.]. Copyright 2017, SLACK Incorporated.

  2. Statistics of the residual refraction errors in laser ranging data

    NASA Technical Reports Server (NTRS)

    Gardner, C. S.

    1977-01-01

    A theoretical model for the range error covariance was derived by assuming that the residual refraction errors are due entirely to errors in the meteorological data which are used to calculate the atmospheric correction. The properties of the covariance function are illustrated by evaluating the theoretical model for the special case of a dense network of weather stations uniformly distributed within a circle.

  3. Refractive Error and Visual Functions in Children with Special Needs Compared with the First Grade School Students in Oman

    PubMed Central

    Vora, Urmi; Khandekar, Rajiv; Natrajan, Sarvanan; Al-Hadrami, Khalfan

    2010-01-01

    Background: We evaluated the refractive status and visual function of children with special needs (other handicap) in 2010 and compared them with healthy 1st grade school students in Oman. Materials and Methods: This was a cohort study. Optometrists recorded vision using a logarithm of minimum angle of resolution (LogMAR) chart. Preferential looking method was used for testing 31 children. Cycloplegic refraction was performed on all children. Contrast sensitivity was tested using 2.5%, 10%, and 100% contrast charts. Ocular movement, alignment, and anterior segment were also assessed. A pediatrician reviewed the health records of all the children at the time of their enrollment in this study to determine if the child had been diagnosed with a systemic condition or syndromes. The visual functions were assessed by study investigators. We estimated the rates and the risk of different visual function defects in children with special needs. Result: The prevalence of refractive error in 70 children (4.7 ± 0.8 years) with special needs (group 1) and 175 normal healthy first grade students (group 2) were 58.5% and 2.9%, respectively. The risk of refractive error was significantly higher in children with special needs [relative risk, 48.1 (95% confidence interval, 17.54–131.8)]. Hyperopia (>1.00 D), myopia (≥ 1.00D) and astigmatism (≥ ±1.00 D) were found in 18.6%, 24.3%, and 27.1%, respectively, in group 1. Six children in this group had defective near vision. Sixteen (80%) children with Down syndrome had refractive error. Seven (50%) children with developmental disorder showed decreased contrast sensitivity. Conclusion: Prevalence of uncorrected refractive error was much higher in children with special needs. Prevalence of strabismus, nystagmus, and reduced contrast sensitivity was also higher in children with special needs. Early vision screening, visual function assessment, correction of refractive error, and frequent follow-up are recommended. PMID:21180428

  4. Predictive Formula for Refraction of Autologous Lenticule Implantation for Hyperopia Correction.

    PubMed

    Li, Meng; Li, Meiyan; Sun, Ling; Ni, Katherine; Zhou, Xingtao

    2017-12-01

    To create a formula to predict refractive correction of autologous lenticule implantation for correction of hyperopia (with myopia in one eye and hyperopia in the contralateral eye). In this prospective study, 10 consecutive patients (20 eyes) who had myopia in one eye and hyperopia in the contralateral eye were included. The preoperative spherical equivalent was -3.31 ± 1.73 diopters (D) for the myopic eyes and +4.46 ± 1.97 D for the hyperopic eyes. For each patient, the myopic eye was treated with small incision lenticule extraction and the lenticule was subsequently implanted into the contralateral hyperopic eye. The average length of follow-up was 17 months. All of the operations were successful without complications. At the last visit, the efficacy index (postoperative uncorrected distance visual acuity/preoperative corrected distance visual acuity [CDVA]) of the hyperopic eyes was 0.94 ± 0.35 and the safety index (postoperative CDVA/preoperative CDVA) was 1.36 ± 0.38. No eyes lost any lines of visual acuity. Six of 10 (60%) of the implanted eyes were within ±1.00 D of the intended refractive target. A predictive formula was derived: Lenticule implantation achieved correction (D) (LAC) = 1.224 Lenticule refractive power (D) (LRP) - 0.063 (R 2 =0.92, P < .001). On corneal topography, there was a significant increase in the corneal anterior surface keratometry value postoperatively, whereas the posterior surface keratometry value remained stable (P > .05). Autologous lenticule implantation could provide a reliable method of correcting hyperopia. The refractive correction formula may require further verification and adjustment. [J Refract Surg. 2017;33(12):827-833.]. Copyright 2017, SLACK Incorporated.

  5. Peripheral refraction and image blur in four meridians in emmetropes and myopes.

    PubMed

    Shen, Jie; Spors, Frank; Egan, Donald; Liu, Chunming

    2018-01-01

    The peripheral refractive error of the human eye has been hypothesized to be a major stimulus for the development of its central refractive error. The purpose of this study was to investigate the changes in the peripheral refractive error across horizontal, vertical and two diagonal meridians in emmetropic and low, moderate and high myopic adults. Thirty-four adult subjects were recruited and aberration was measured using a modified commercial aberrometer. We then computed the refractive error in power vector notation from second-order Zernike terms. Statistical analysis was performed to evaluate the statistical differences in refractive error profiles between the subject groups and across all measured visual field meridians. Small amounts of relative myopic shift were observed in emmetropic and low myopic subjects. However, moderate and high myopic subjects exhibited a relative hyperopic shift in all four meridians. Astigmatism J 0 and J 45 had quadratic or linear changes dependent on the visual field meridians. Peripheral Sphero-Cylindrical Retinal Image Blur increased in emmetropic eyes in most of the measured visual fields. The findings indicate an overall emmetropic or slightly relative myopic periphery (spherical or oblate retinal shape) formed in emmetropes and low myopes, while moderate and high myopes form relative hyperopic periphery (prolate, or less oblate, retinal shape). In general, human emmetropic eyes demonstrate higher amount of peripheral retinal image blur.

  6. Small Incision Lenticule Extraction (SMILE) versus Femtosecond Laser-Assisted In Situ Keratomileusis (FS-LASIK) for Myopia: A Systematic Review and Meta-Analysis

    PubMed Central

    Shen, Zeren; Shi, Keda; Yu, Yinhui; Yu, Xiaoning; Lin, Yuchen; Yao, Ke

    2016-01-01

    Purpose The goal of this study was to compare small incision lenticule extraction (SMILE) with femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for treating myopia. Methods The CENTRAL, EMBASE, PubMed databases and a Chinese database (SinoMed) were searched in May of 2016. Twelve studies with 1,076 eyes, which included three randomized controlled trials (RCTs) and nine cohorts, met our inclusion criteria. The overall quality of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) working group framework. Data were extracted and analysed at three to six months postoperatively. Primary outcome measures included a loss of one or more lines of best spectacle corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA) of 20/20 or better, mean logMAR UCVA, postoperative mean spherical equivalent (SE) and postoperative refraction within ±1.0 D of the target refraction. Secondary outcome measures included ocular surface disease index (OSDI), tear breakup time (TBUT) and Schirmer’s 1 test (S1T) as dry eye parameters, along with corneal sensitivity. Results The overall quality of evidence was considered to be low to very low. Pooled results revealed no significant differences between the two groups with regard to a loss of one or more lines in the BSCVA (OR 1.71; 95% CI: 0.81, 3.63; P = 0.16), UCVA of 20/20 or better (OR 0.71; 95% CI: 0.44, 1.15; P = 0.16), logMAR UCVA (MD 0.00; 95% CI: -0.03, 0.04; P = 0.87), postoperative refractive SE (MD -0.00; 95% CI: -0.05, 0.05; P = 0.97) or postoperative refraction within ±1.0 D of the target refraction (OR 0.78; 95% CI: 0.22, 2.77; P = 0.70) within six months postoperatively. The pooled analysis also indicated that the FS-LASIK group suffered more severely from dry eye symptoms (OSDI; MD -6.68; 95% CI: -11.76, -2.00; P = 0.006) and lower corneal sensitivity (MD 12.40; 95% CI: 10.23, 14.56; P < 0.00001) at six months postoperatively. Conclusions In conclusion, both FS-LASIK and SMILE are safe, effective and predictable surgical options for treating myopia. However, dry eye symptoms and loss of corneal sensitivity may occur less frequently after SMILE than after FS-LASIK. PMID:27367803

  7. Laser in situ keratomileusis for astigmatism ≤ 0.75 Diopter combined with low myopia: a retrospective data analysis

    PubMed Central

    2014-01-01

    Background This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D). Methods 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere between -0.25 D and -2.75 D, and who had completed 4-month follow-up. Three subgroups defined by the magnitude of preoperative manifest refractive cylinder (0.25, 0.50, and 0.75 D) were formed. Manifest refraction, uncorrected and corrected visual acuity were assessed pre- and postoperatively. The astigmatic changes achieved were determined using the Alpins vector analysis. Results After 4 months (120.0 ± 27.6 days) of follow-up, a mean uncorrected distant visual acuity of 0.07 ± 0.11 logMAR and a mean manifest refraction spherical equivalent of -0.06 ± 0.56 D were found. There was no statistically significant difference in efficacy and safety between the preoperative cylinder groups. Astigmatic overcorrection for preoperative cylinder of ≤ 0.50 D was suggested by the correction index, the magnitude of error, the index of success, and the flattening index. Conclusions Low myopic eyes with a preoperative cylinder of ≤ 0.50 D were significantly overcorrected with regard to cylinder correction when combined with low myopic LASIK. Accordingly, we are cautious in recommending full astigmatic correction for eyes with low myopia and manifest cylinder of ≤ 0.50 D. PMID:24393469

  8. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation.

    PubMed

    Hirnschall, Nino; Norrby, Sverker; Weber, Maria; Maedel, Sophie; Amir-Asgari, Sahand; Findl, Oliver

    2015-01-01

    To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6-29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r(2)=-0.42 (p<0.0001), r(2)=-0.5 (p<0.0001), r(2)=-0.34 (p=0.010), r(2)=-0.28 (p=0.049) and r(2)<0.001 (p=0.866), respectively, ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Peripheral refraction profiles in subjects with low foveal refractive errors.

    PubMed

    Tabernero, Juan; Ohlendorf, Arne; Fischer, M Dominik; Bruckmann, Anna R; Schiefer, Ulrich; Schaeffel, Frank

    2011-03-01

    To study the variability of peripheral refraction in a population of 43 subjects with low foveal refractive errors. A scan of the refractive error in the vertical pupil meridian of the right eye of 43 subjects (age range, 18 to 80 years, foveal spherical equivalent, < ± 2.5 diopter) over the central ± 45° of the visual field was performed using a recently developed angular scanning photorefractor. Refraction profiles across the visual field were fitted with four different models: (1) "flat model" (refractions about constant across the visual field), (2) "parabolic model" (refractions follow about a parabolic function), (3) "bi-linear model" (linear change of refractions with eccentricity from the fovea to the periphery), and (4) "box model" ("flat" central area with a linear change in refraction from a certain peripheral angle). Based on the minimal residuals of each fit, the subjects were classified into one of the four models. The "box model" accurately described the peripheral refractions in about 50% of the subjects. Peripheral refractions in six subjects were better characterized by a "linear model," in eight subjects by a "flat model," and in eight by the "parabolic model." Even after assignment to one of the models, the variability remained strikingly large, ranging from -0.75 to 6 diopter in the temporal retina at 45° eccentricity. The most common peripheral refraction profile (observed in nearly 50% of our population) was best described by the "box model." The high variability among subjects may limit attempts to reduce myopia progression with a uniform lens design and may rather call for a customized approach.

  10. Do Peripheral Refraction and Aberration Profiles Vary with the Type of Myopia? - An Illustration Using a Ray-Tracing Approach

    PubMed Central

    Bakaraju, Ravi C.; Ehrmann, Klaus; Papas, Eric B.; Ho, Arthur

    2010-01-01

    Purpose Myopia is considered to be the most common refractive error occurring in children and young adults, around the world. Motivated to elucidate how the process of emmetropization is disrupted, potentially causing myopia and its progression, researchers have shown great interest in peripheral refraction. This study assessed the effect of the myopia type, either refractive or axial, on peripheral refraction and aberration profiles. Methods Using customized schematic eye models for myopia in a ray tracing algorithm, peripheral aberrations, including the refractive error, were calculated as a function of myopia type. Results In all the selected models, hyperopic shifts in the mean spherical equivalent (MSE) component were found whose magnitude seemed to be largely dependent on the field angle. The MSE profiles showed larger hyperopic shifts for the axial type of myopic models than the refractive ones and were evident in -4 and -6 D prescriptions. Additionally, greater levels of astigmatic component (J180) were also seen in axial-length-dependent models, while refractive models showed higher levels of spherical aberration and coma. Conclusion This study has indicated that myopic eyes with primarily an axial component may have a greater risk of progression than their refractive counterparts albeit with the same degree of refractive error. This prediction emerges from the presented theoretical ray tracing model and, therefore, requires clinical confirmation.

  11. Adjuvant corneal crosslinking to prevent hyperopic LASIK regression.

    PubMed

    Aslanides, Ioannis M; Mukherjee, Achyut N

    2013-01-01

    To report the long term outcomes, safety, stability, and efficacy in a pilot series of simultaneous hyperopic laser assisted in situ keratomileusis (LASIK) and corneal crosslinking (CXL). A small cohort series of five eyes, with clinically suboptimal topography and/or thickness, underwent LASIK surgery with immediate riboflavin application under the flap, followed by UV light irradiation. Postoperative assessment was performed at 1, 3, 6, and 12 months, with late follow up at 4 years, and results were compared with a matched cohort that received LASIK only. The average age of the LASIK-CXL group was 39 years (26-46), and the average spherical equivalent hyperopic refractive error was +3.45 diopters (standard deviation 0.76; range 2.5 to 4.5). All eyes maintained refractive stability over the 4 years. There were no complications related to CXL, and topographic and clinical outcomes were as expected for standard LASIK. This limited series suggests that simultaneous LASIK and CXL for hyperopia is safe. Outcomes of the small cohort suggest that this technique may be promising for ameliorating hyperopic regression, presumed to be biomechanical in origin, and may also address ectasia risk.

  12. The ipRGC-Driven Pupil Response with Light Exposure, Refractive Error, and Sleep.

    PubMed

    Abbott, Kaleb S; Queener, Hope M; Ostrin, Lisa A

    2018-04-01

    We investigated links between the intrinsically photosensitive retinal ganglion cells, light exposure, refractive error, and sleep. Results showed that morning melatonin was associated with light exposure, with modest differences in sleep quality between myopes and emmetropes. Findings suggest a complex relationship between light exposure and these physiological processes. Intrinsically photosensitive retinal ganglion cells (ipRGCs) signal environmental light, with pathways to the midbrain to control pupil size and circadian rhythm. Evidence suggests that light exposure plays a role in refractive error development. Our goal was to investigate links between light exposure, ipRGCs, refractive error, and sleep. Fifty subjects, aged 17-40, participated (19 emmetropes and 31 myopes). A subset of subjects (n = 24) wore an Actiwatch Spectrum for 1 week. The Pittsburgh Sleep Quality Index (PSQI) was administered, and saliva samples were collected for melatonin analysis. The post-illumination pupil response (PIPR) to 1 s and 5 s long- and short-wavelength stimuli was measured. Pupil metrics included the 6 s and 30 s PIPR and early and late area under the curve. Subjects spent 104.8 ± 46.6 min outdoors per day over the previous week. Morning melatonin concentration (6.9 ± 3.5 pg/ml) was significantly associated with time outdoors and objectively measured light exposure (P = .01 and .002, respectively). Pupil metrics were not significantly associated with light exposure or refractive error. PSQI scores indicated good sleep quality for emmetropes (score 4.2 ± 2.3) and poor sleep quality for myopes (5.6 ± 2.2, P = .04). We found that light exposure and time outdoors influenced morning melatonin concentration. No differences in melatonin or the ipRGC-driven pupil response were observed between refractive error groups, although myopes exhibited poor sleep quality compared to emmetropes. Findings suggest that a complex relationship between light exposure, ipRGCs, refractive error, and sleep exists.

  13. Investigating the relationship between foveal morphology and refractive error in a population with infantile nystagmus syndrome.

    PubMed

    Healey, Natasha; McLoone, Eibhlin; Mahon, Gerald; Jackson, A Jonathan; Saunders, Kathryn J; McClelland, Julie F

    2013-04-26

    We explored associations between refractive error and foveal hypoplasia in infantile nystagmus syndrome (INS). We recruited 50 participants with INS (albinism n = 33, nonalbinism infantile nystagmus [NAIN] n = 17) aged 4 to 48 years. Cycloplegic refractive error and logMAR acuity were obtained. Spherical equivalent (SER), most ametropic meridian (MAM) refractive error, and better eye acuity (VA) were used for analyses. High resolution spectral-domain optical coherence tomography (SD-OCT) was used to obtain foveal scans, which were graded using the Foveal Hypoplasia Grading Scale. Associations between grades of severity of foveal hypoplasia, and refractive error and VA were explored. Participants with more severe foveal hypoplasia had significantly higher MAMs and SERs (Kruskal-Wallis H test P = 0.005 and P = 0.008, respectively). There were no statistically significant associations between foveal hypoplasia and cylindrical refractive error (Kruskal-Wallis H test P = 0.144). Analyses demonstrated significant differences between participants with albinism or NAIN in terms of SER and MAM (Mann-Whitney U test P = 0.001). There were no statistically significant differences between astigmatic errors between participants with albinism and NAIN. Controlling for the effects of albinism, results demonstrated no significant associations between SER, and MAM and foveal hypoplasia (partial correlation P > 0.05). Poorer visual acuity was associated statistically significantly with more severe foveal hypoplasia (Kruskal-Wallis H test P = 0.001) and with a diagnosis of albinism (Mann-Whitney U test P = 0.001). Increasing severity of foveal hypoplasia is associated with poorer VA, reflecting reduced cone density in INS. Individuals with INS also demonstrate a significant association between more severe foveal hypoplasia and increasing hyperopia. However, in the absence of albinism, there is no significant relation between refractive outcome and degree of foveal hypoplasia, suggesting that foveal maldevelopment in isolation does not impair significantly the emmetropization process. It likely is that impaired emmetropization evidenced in the albinism group may be attributed to the whole eye effect of albinism.

  14. Pre- and postoperative optical resolution of the cornea: a preliminary report

    NASA Astrophysics Data System (ADS)

    Parel, Jean-Marie A.; Simon, Gabriel; Rol, Pascal O.; Ren, Qiushi; Lee, William E.

    1993-06-01

    The effect of novel refractive surgical techniques on visual acuity and contrast sensitivity is normally determined by the outcome of human clinical trials. For example, ArF laser photorefractive keratoplasty follows an algorithm based on the patient's preoperative data for keratometry, refraction, pachometry, and ocular length all measured with ultrasound. A normalized ablation rate (which is function of the laser fluence), and the desired refractive correction are then used to calculate the ablation depth. On the day of surgery, the epithelium is mechanically removed and the bare cornea photoablated. Finally, the cornea may be medicated with a topical application of antibiotics and the eye is patched. On postoperative day 7, the epithelium is healed and visual acuity and keratometry are measured. With PRK, the theoretical outcome refraction should be within +/- 0.25 D. Thus far however, reproducibility is only of +/- 2 D. We believe the large discrepancy between theory and practice is due to several parameters that vary patient-to-patient.

  15. Refractive errors in medical students in Singapore.

    PubMed

    Woo, W W; Lim, K A; Yang, H; Lim, X Y; Liew, F; Lee, Y S; Saw, S M

    2004-10-01

    Refractive errors are becoming more of a problem in many societies, with prevalence rates of myopia in many Asian urban countries reaching epidemic proportions. This study aims to determine the prevalence rates of various refractive errors in Singapore medical students. 157 second year medical students (aged 19-23 years) in Singapore were examined. Refractive error measurements were determined using a stand-alone autorefractor. Additional demographical data was obtained via questionnaires filled in by the students. The prevalence rate of myopia in Singapore medical students was 89.8 percent (Spherical equivalence (SE) at least -0.50 D). Hyperopia was present in 1.3 percent (SE more than +0.50 D) of the participants and the overall astigmatism prevalence rate was 82.2 percent (Cylinder at least 0.50 D). Prevalence rates of myopia and astigmatism in second year Singapore medical students are one of the highest in the world.

  16. Peripheral refractive correction and automated perimetric profiles.

    PubMed

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  17. Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation.

    PubMed

    Iijima, Ayaka; Shimizu, Kimiya; Yamagishi, Mayumi; Kobashi, Hidenaga; Igarashi, Akihito; Kamiya, Kazutaka

    2016-12-01

    To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant ™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. From unseen to seen: tackling the global burden of uncorrected refractive errors.

    PubMed

    Durr, Nicholas J; Dave, Shivang R; Lage, Eduardo; Marcos, Susana; Thorn, Frank; Lim, Daryl

    2014-07-11

    Worldwide, more than one billion people suffer from poor vision because they do not have the eyeglasses they need. Their uncorrected refractive errors are a major cause of global disability and drastically reduce productivity, educational opportunities, and overall quality of life. The problem persists most prevalently in low-resource settings, even though prescription eyeglasses serve as a simple, effective, and largely affordable solution. In this review, we discuss barriers to obtaining, and approaches for providing, refractive eye care. We also highlight emerging technologies that are being developed to increase the accessibility of eye care. Finally, we describe opportunities that exist for engineers to develop new solutions to positively impact the diagnosis and treatment of correctable refractive errors in low-resource settings.

  19. Relationship between lenticular power and refractive error in children with hyperopia

    PubMed Central

    Tomomatsu, Takeshi; Kono, Shinjiro; Arimura, Shogo; Tomomatsu, Yoko; Matsumura, Takehiro; Takihara, Yuji; Inatani, Masaru; Takamura, Yoshihiro

    2013-01-01

    Objectives To evaluate the contribution of axial length, and lenticular and corneal power to the spherical equivalent refractive error in children with hyperopia between 3 and 13 years of age, using noncontact optical biometry. Methods There were 62 children between 3 and 13 years of age with hyperopia (+2 diopters [D] or more) who underwent automated refraction measurement with cycloplegia, to measure spherical equivalent refractive error and corneal power. Axial length was measured using an optic biometer that does not require contact with the cornea. The refractive power of the lens was calculated using the Sanders-Retzlaff-Kraff formula. Single regression analysis was used to evaluate the correlation among the optical parameters. Results There was a significant positive correlation between age and axial length (P = 0.0014); however, the degree of hyperopia did not decrease with aging (P = 0.59). There was a significant negative correlation between age and the refractive power of the lens (P = 0.0001) but not that of the cornea (P = 0.43). A significant negative correlation was observed between the degree of hyperopia and lenticular power (P < 0.0001). Conclusion Although this study is small scale and cross sectional, the analysis, using noncontact biometry, showed that lenticular power was negatively correlated with refractive error and age, indicating that lower lens power may contribute to the degree of hyperopia. PMID:23576859

  20. Prevalence of refractive errors in Tibetan adolescents.

    PubMed

    Qian, Xuehan; Liu, Beihong; Wang, Jing; Wei, Nan; Qi, Xiaoli; Li, Xue; Li, Jing; Zhang, Ying; Hua, Ning; Ning, Yuxian; Ding, Gang; Ma, Xu; Wang, Binbin

    2018-05-11

    The prevalence of adolescent eye disease in remote areas of the Qinghai-Tibet Plateau has rarely been reported. To understand the prevalence of common eye diseases in Tibet, we performed ocular-disease screening on students from primary and secondary schools in Tibet, and compared the prevalence to that in the Central China Plain (referred to here as the "plains area"). The refractive status of students was evaluated with a Spot™ vision screener. The test was conducted three or fewer times for both eyes of each student and results with best correction were recorded. A total of 3246 students from primary and secondary schools in the Tibet Naidong district were screened, yielding a refractive error rate of 28.51%, which was significantly lower than that of the plains group (28.51% vs. 56.92%, p < 0.001). In both groups, the prevalence of refractive errors among females was higher than that among males. We found that Tibetan adolescents had a lower prevalence of refractive errors than did adolescents in the plains area, which may be related to less intensive schooling and greater exposure to sunlight.

  1. Comparison of surgically induced astigmatism in patients with horizontal rectus muscle recession

    PubMed Central

    Çakmak, Harun; Kocatürk, Tolga; Dündar, Sema Oruç

    2014-01-01

    AIM To compare surgically induced astigmatism (SIA) following horizontal rectus muscle recession surgery between suspension recession with both the “hang-back” technique and conventional recession technique. METHODS Totally, 48 eyes of 24 patients who had undergone horizontal rectus muscle recession surgery were reviewed retrospectively. The patients were divided into two groups. Twelve patients were operated on by the hang-back technique (Group 1), and 12 by the conventional recession technique (Group 2). SIA was calculated on the 1st wk, 1st and in the 3rd mo after surgery using the SIA calculator. RESULTS SIA was statistically higher in the Group 1 all postoperative follow-up. SIA was the highest in the 1st wk, and decreased gradually in both groups. CONCLUSION The suspension recession technique induced much more SIA than the conventional recession technique. This difference also continued in the following visits. Therefore, the refractive power should be checked postoperatively in order to avoid refractive amblyopia. Conventional recession surgery should be the preferred method so as to minimize the postoperative refractive changes in patients with amblyopia. PMID:25161948

  2. Ocular manifestations of sickle cell disease and genetic susceptibility for refractive errors

    PubMed Central

    Shukla, Palak; Verma, Henu; Patel, Santosh; Patra, P. K.; Bhaskar, L. V. K. S.

    2017-01-01

    PURPOSE: Sickle cell disease (SCD) is the most common and serious form of an inherited blood disorder that lead to higher risk of early mortality. SCD patients are at high risk for developing multiorgan acute and chronic complications linked with significant morbidity and mortality. Some of the ophthalmological complications of SCD include retinal changes, refractive errors, vitreous hemorrhage, and abnormalities of the cornea. MATERIALS AND METHODS: The present study includes 96 SCD patients. A dilated comprehensive eye examination was performed to know the status of retinopathy. Refractive errors were measured in all patients. In patients with >10 years of age, cycloplegia was not performed before autorefractometry. A subset of fifty patients’ genotyping was done for NOS3 27-base pair (bp) variable number of tandem repeat (VNTR) and IL4 intron-3 VNTR polymorphisms using polymerase chain reaction-electrophoresis. Chi-square test was performed to test the association between the polymorphisms and refractive errors. RESULTS: The results of the present study revealed that 63.5% of patients have myopia followed by 19.8% hyperopia. NOS3 27-bp VNTR genotypes significantly deviated from Hardy–Weinberg equilibrium (P < 0.0001). Although IL4 70-bp VNTR increased the risk of developing refractive errors, it is not statistically significant. However, NOS3 27-bp VNTR significantly reduced the risk of development of myopia. CONCLUSION: In summary, our study documents the prevalence of refractive errors along with some retinal changes in Indian SCD patients. Further, this study demonstrates that the NOS3 VNTR contributes to the susceptibility to development of myopia in SCD cases. PMID:29018763

  3. Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study.

    PubMed

    Nakano, Tadashi; Hayashi, Takeshi; Nakagawa, Toru; Honda, Toru; Owada, Satoshi; Endo, Hitoshi; Tatemichi, Masayuki

    2018-04-05

    This retrospective cohort study primarily aimed to investigate the possible association of computer use with visual field abnormalities (VFA) among Japanese workers. The study included 2,377 workers (mean age 45.7 [standard deviation, 8.3] years; 2,229 men and 148 women) who initially exhibited no VFA during frequency doubling technology perimetry (FDT) testing. Subjects then underwent annual follow-up FDT testing for 7 years, and VFA were determined using a FDT-test protocol (FDT-VFA). Subjects with FDT-VFA were examined by ophthalmologists. Baseline data about the mean duration of computer use during a 5-year period and refractive errors were obtained via self-administered questionnaire and evaluations for refractive errors (use of eyeglasses or contact lenses), respectively. A Cox proportional hazard analysis demonstrated that heavy computer users (>8 hr/day) had a significantly increased risk of FDT-VFA (hazard ratio [HR] 2.85; 95% confidence interval [CI], 1.26-6.48) relative to light users (<4 hr/day), and this association was strengthened among subjects with refractive errors (HR 4.48; 95% CI, 1.87-10.74). The computer usage history also significantly correlated with FDT-VFA among subject with refractive errors (P < 0.05), and 73.1% of subjects with FDT-VFA and refractive errors were diagnosed with glaucoma or ocular hypertension. The incidence of FDT-VFA appears to be increased among Japanese workers who are heavy computer users, particularly if they have refractive errors. Further investigations of epidemiology and causality are warranted.

  4. Ocular manifestations of sickle cell disease and genetic susceptibility for refractive errors.

    PubMed

    Shukla, Palak; Verma, Henu; Patel, Santosh; Patra, P K; Bhaskar, L V K S

    2017-01-01

    Sickle cell disease (SCD) is the most common and serious form of an inherited blood disorder that lead to higher risk of early mortality. SCD patients are at high risk for developing multiorgan acute and chronic complications linked with significant morbidity and mortality. Some of the ophthalmological complications of SCD include retinal changes, refractive errors, vitreous hemorrhage, and abnormalities of the cornea. The present study includes 96 SCD patients. A dilated comprehensive eye examination was performed to know the status of retinopathy. Refractive errors were measured in all patients. In patients with >10 years of age, cycloplegia was not performed before autorefractometry. A subset of fifty patients' genotyping was done for NOS3 27-base pair (bp) variable number of tandem repeat (VNTR) and IL4 intron-3 VNTR polymorphisms using polymerase chain reaction-electrophoresis. Chi-square test was performed to test the association between the polymorphisms and refractive errors. The results of the present study revealed that 63.5% of patients have myopia followed by 19.8% hyperopia. NOS3 27-bp VNTR genotypes significantly deviated from Hardy-Weinberg equilibrium ( P < 0.0001). Although IL4 70-bp VNTR increased the risk of developing refractive errors, it is not statistically significant. However, NOS3 27-bp VNTR significantly reduced the risk of development of myopia. In summary, our study documents the prevalence of refractive errors along with some retinal changes in Indian SCD patients. Further, this study demonstrates that the NOS3 VNTR contributes to the susceptibility to development of myopia in SCD cases.

  5. [Determining factors for deciding whether or not to treat refractive errors and cataract in people with a learning disability].

    PubMed

    van Isterdael, C E D; Stilma, J S; Bezemer, P D; Tijmes, N T

    2008-05-03

    A study into the treatment of refractive errors and cataract in a selected population with learning disabilities. Design. Retrospective. In the years 1993-2003, 5205 people (mean age: 39 years) were referred to the visual advisory centre of Bartiméus (one of three institutes for the visually impaired in the Netherlands) by learning disability physicians and were assessed ophthalmologically. This assessment consisted of a measurement of visual acuity and refractive error, slitlamp examination and retinoscopy, and was performed at the client's accommodation. Advised treatment for spectacle prescriptions and referral for cataract surgery were registered. Refractive errors were found in 35% (1845/5205) of the patients with learning disabilities; 49% (905/1845) already wore spectacles; another 14% (265/1845) were prescribed spectacles for the first time. Of those with presbyopia, 12% (232/1865) had reading glasses and 10% (181/1865) were given a first prescription for spectacles. The most important determinant for not prescribing spectacles was: presence of severe learning disability (odds ratio (OR): 3.7). Cataract was present in 10% (497/5205) of the population; 399 patients were advised to be referred for surgery, 55% (219/399) were referred ofwhom 26% (57/219) had surgery. Moderately severe bilateral cataract was the only determinant of cataract surgery (OR: 7.8). Refractive errors and cataract were not always treated in this group. One of the reasons for non-treatment of refractive errors was a severe learning disability. The reason for treatment or non-treatment in patients with cataract was less clear.

  6. Two-dimensional simulation of eccentric photorefraction images for ametropes: factors influencing the measurement.

    PubMed

    Wu, Yifei; Thibos, Larry N; Candy, T Rowan

    2018-05-07

    Eccentric photorefraction and Purkinje image tracking are used to estimate refractive state and eye position simultaneously. Beyond vision screening, they provide insight into typical and atypical visual development. Systematic analysis of the effect of refractive error and spectacles on photorefraction data is needed to gauge the accuracy and precision of the technique. Simulation of two-dimensional, double-pass eccentric photorefraction was performed (Zemax). The inward pass included appropriate light sources, lenses and a single surface pupil plane eye model to create an extended retinal image that served as the source for the outward pass. Refractive state, as computed from the luminance gradient in the image of the pupil captured by the model's camera, was evaluated for a range of refractive errors (-15D to +15D), pupil sizes (3 mm to 7 mm) and two sets of higher-order monochromatic aberrations. Instrument calibration was simulated using -8D to +8D trial lenses at the spectacle plane for: (1) vertex distances from 3 mm to 23 mm, (2) uncorrected and corrected hyperopic refractive errors of +4D and +7D, and (3) uncorrected and corrected astigmatism of 4D at four different axes. Empirical calibration of a commercial photorefractor was also compared with a wavefront aberrometer for human eyes. The pupil luminance gradient varied linearly with refractive state for defocus less than approximately 4D (5 mm pupil). For larger errors, the gradient magnitude saturated and then reduced, leading to under-estimation of refractive state. Additional inaccuracy (up to 1D for 8D of defocus) resulted from spectacle magnification in the pupil image, which would reduce precision in situations where vertex distance is variable. The empirical calibration revealed a constant offset between the two clinical instruments. Computational modelling demonstrates the principles and limitations of photorefraction to help users avoid potential measurement errors. Factors that could cause clinically significant errors in photorefraction estimates include high refractive error, vertex distance and magnification effects of a spectacle lens, increased higher-order monochromatic aberrations, and changes in primary spherical aberration with accommodation. The impact of these errors increases with increasing defocus. © 2018 The Authors Ophthalmic & Physiological Optics © 2018 The College of Optometrists.

  7. Introduction of a Toric Intraocular Lens to a Non-Refractive Cataract Practice: Challenges and Outcomes

    PubMed Central

    Kirwan, Clare; Nolan, John M; Stack, Jim; Dooley, Ian; Moore, Johnny; Moore, Tara CB; Beatty, Stephen

    2016-01-01

    Aim To identify challenges inherent in introducing a toric intraocular lens (IOL) to a non-refractive cataract practice, and evaluate residual astigmatism achieved and its impact on patient satisfaction. Methods Following introduction of a toric IOL to a cataract practice with all procedures undertaken by a single, non-refractive, surgeon (SB), pre-operative, intra-operative and post-operative data was analysed. Attenuation of anticipated post-operative astigmatism was examined, and subjectively perceived visual functioning was assessed using validated questionnaires. Results Median difference vector (DV, the induced astigmatic change [by magnitude and axis] that would enable the initial surgery to achieve intended target) was 0.93D; median anticipated DV with a non-toric IOL was 2.38D. One eye exhibited 0.75D residual astigmatism, compared to 3.8D anticipated residual astigmatism with a non-toric IOL. 100% of respondents reported satisfaction of ≥ 6/10, with 37.84% of respondents entirely satisfied (10/10). 17 patients (38.63%) reported no symptoms of dysphotopsia (dysphoptosia score 0/10), only 3 respondents (6.8%) reported a clinically meaningful level of dysphotopsia (≥ 4/10). Mean post-operative NEI VF-11 score was 0.54 (+/-0.83; scale 0 – 4). Conclusion Use of a toric IOL to manage astigmatism during cataract surgery results in less post-operative astigmatism than a non-toric IOL, resulting in avoidance of unacceptable post-operative astigmatism. PMID:27830188

  8. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed Central

    Hastings, Gareth D.; Marsack, Jason D.; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A.

    2017-01-01

    Purpose To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Methods Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. Results For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ±SD was −0.06 ±0.04 with both refractions; dilated was −0.05 ±0.04 with the objective, and −0.05 ±0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. Conclusions A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. PMID:28370389

  9. Trends in refractive surgery at an academic center: 2007-2009.

    PubMed

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume.

  10. Trends in refractive surgery at an academic center: 2007-2009

    PubMed Central

    2011-01-01

    Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Conclusions Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume. PMID:21569564

  11. Refractive errors in children with autism in a developing country.

    PubMed

    Ezegwui, I R; Lawrence, L; Aghaji, A E; Okoye, O I; Okoye, O; Onwasigwe, E N; Ebigbo, P O

    2014-01-01

    In a resource-limited country visual problems of mentally challenged individuals are often neglected. The present study aims to study refractive errors in children diagnosed with autism in a developing country. Ophthalmic examination was carried out on children diagnosed with autism attending a school for the mentally challenged in Enugu, Nigeria between December 2009 and May 2010. Visual acuity was assessed using Lea symbols. Anterior and posterior segments were examined. Cycloplegic refraction was performed. Data was entered on the protocol prepared for the study and analyzed using Statistical Package for the Social Sciences version 17 (Chicago IL, USA). A total of 21 children with autism were enrolled in the school; 18 of whom were examined giving coverage of 85.7%. The age range was 5-15 years, with a mean of 10.28 years (standard deviation ± 3.20). There were 13 boys and 5 girls. One child had bilateral temporal pallor of the disc and one had bilateral maculopathy with diffuse chorioretinal atrophy. Refraction revealed 4 children (22.2%) had astigmatism and 2 children (11.1%) had hypermetropia. Significant refractive error mainly astigmatism was noted in the children with autism. Identifying refractive errors in these children early and providing appropriate corrective lenses may help optimize their visual functioning and impact their activities of daily life in a positive way.

  12. Refractive error characteristics of early and advanced presbyopic individuals.

    DOT National Transportation Integrated Search

    1977-07-01

    The frequency and distribution of ocular refractive errors among middle-aged and older people were obtained from a nonclinical population holding a variety of blue-collar, clerical, and technical jobs. The 422 individuals ranged in age from 35 to 69 ...

  13. Do outside temperature and sunlight duration influence the outcome of laser refractive surgery? Results from the Hamburg Weather Study

    PubMed Central

    Neuhaus-Richard, Ines; Frings, Andreas; Görsch, Isabel Caroline; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan Johannes; Richard, Gisbert

    2014-01-01

    Purpose To examine the impact of temperature and sunlight duration on refractive and visual outcome of laser-assisted in situ keratomileusis (LASIK) in myopic eyes. Setting University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. Design Retrospective, cross-sectional data analysis. Methods This study comprised 1,052 eyes of 1,052 consecutive myopic patients (419 males, 633 females; mean age at surgery 35.0±9.0 years) with a mean preoperative refractive spherical equivalent (SE) of −3.88±1.85 diopters (D). Two subgroups were defined, comprising patients undergoing surgery during either meteorological winter or summer. Manifest refraction, uncorrected, and corrected distant visual acuity (UDVA and CDVA) were assessed pre- and postoperatively. We applied robust regression analysis with efficiency index (EI), safety index (SI), and postoperative SE (in D) as dependent variables. Results At the 1-month (33.0±5.0 days) follow-up, the mean postoperative SE was −0.18±0.44 D. Bivariate comparisons showed that statistically significant better EI was related to days with lower temperature. We obtained a significant difference for SI which suggested that low temperature had a positive influence on SI. No change by more than one line on LogMAR scale was obtained. Conclusion Although being statistically significant, there was no clinically relevant difference in the outcome of LASIK, which demonstrates its highly standardized quality. Prospective, longitudinal studies are warranted to address meteorotropic reactions through evaluating defined meteorological parameters. PMID:24966665

  14. Refraction corrected calibration for aquatic locomotion research: application of Snell's law improves spatial accuracy.

    PubMed

    Henrion, Sebastian; Spoor, Cees W; Pieters, Remco P M; Müller, Ulrike K; van Leeuwen, Johan L

    2015-07-07

    Images of underwater objects are distorted by refraction at the water-glass-air interfaces and these distortions can lead to substantial errors when reconstructing the objects' position and shape. So far, aquatic locomotion studies have minimized refraction in their experimental setups and used the direct linear transform algorithm (DLT) to reconstruct position information, which does not model refraction explicitly. Here we present a refraction corrected ray-tracing algorithm (RCRT) that reconstructs position information using Snell's law. We validated this reconstruction by calculating 3D reconstruction error-the difference between actual and reconstructed position of a marker. We found that reconstruction error is small (typically less than 1%). Compared with the DLT algorithm, the RCRT has overall lower reconstruction errors, especially outside the calibration volume, and errors are essentially insensitive to camera position and orientation and the number and position of the calibration points. To demonstrate the effectiveness of the RCRT, we tracked an anatomical marker on a seahorse recorded with four cameras to reconstruct the swimming trajectory for six different camera configurations. The RCRT algorithm is accurate and robust and it allows cameras to be oriented at large angles of incidence and facilitates the development of accurate tracking algorithms to quantify aquatic manoeuvers.

  15. Automatic diagnostic system for measuring ocular refractive errors

    NASA Astrophysics Data System (ADS)

    Ventura, Liliane; Chiaradia, Caio; de Sousa, Sidney J. F.; de Castro, Jarbas C.

    1996-05-01

    Ocular refractive errors (myopia, hyperopia and astigmatism) are automatic and objectively determined by projecting a light target onto the retina using an infra-red (850 nm) diode laser. The light vergence which emerges from the eye (light scattered from the retina) is evaluated in order to determine the corresponding ametropia. The system basically consists of projecting a target (ring) onto the retina and analyzing the scattered light with a CCD camera. The light scattered by the eye is divided into six portions (3 meridians) by using a mask and a set of six prisms. The distance between the two images provided by each of the meridians, leads to the refractive error of the referred meridian. Hence, it is possible to determine the refractive error at three different meridians, which gives the exact solution for the eye's refractive error (spherical and cylindrical components and the axis of the astigmatism). The computational basis used for the image analysis is a heuristic search, which provides satisfactory calculation times for our purposes. The peculiar shape of the target, a ring, provides a wider range of measurement and also saves parts of the retina from unnecessary laser irradiation. Measurements were done in artificial and in vivo eyes (using cicloplegics) and the results were in good agreement with the retinoscopic measurements.

  16. The prevalence of refractive errors in 6- to 15-year-old schoolchildren in Dezful, Iran.

    PubMed

    Norouzirad, Reza; Hashemi, Hassan; Yekta, Abbasali; Nirouzad, Fereidon; Ostadimoghaddam, Hadi; Yazdani, Negareh; Dadbin, Nooshin; Javaherforoushzadeh, Ali; Khabazkhoob, Mehdi

    2015-01-01

    To determine the prevalence of refractive errors, among 6- to 15-year-old schoolchildren in the city of Dezful in western Iran. In this cross-sectional study, 1375 Dezful schoolchildren were selected through multistage cluster sampling. After obtaining written consent, participants had uncorrected and corrected visual acuity tests and cycloplegic refraction at the school site. Refractive errors were defined as myopia [spherical equivalent (SE) -0.5 diopter (D)], hyperopia (SE ≥ 2.0D), and astigmatism (cylinder error > 0.5D). 1151 (83.7%) schoolchildren participated in the study. Of these, 1130 completed their examinations. 21 individuals were excluded because of poor cooperation and contraindication for cycloplegic refraction. Prevalence of myopia, hyperopia, and astigmatism were 14.9% (95% confidence interval (CI): 10.1-19.6), 12.9% (95% CI: 7.2-18.6), and 45.3% (95% CI: 40.3-50.3), respectively. Multiple logistic regression analysis showed an age-related increase in myopia prevalence (p < 0.001) and a decrease in hyperopia prevalence (p < 0.001). There was a higher prevalence of myopia in boys (p<0.001) and hyperopia in girls (p = 0.007). This study showed a considerably high prevalence of refractive errors among the Iranian population of schoolchildren in Dezful in the west of Iran. The prevalence of myopia is considerably high compared to previous studies in Iran and increases with age.

  17. Preventable visual impairment in children 
with nonprofound intellectual disability.

    PubMed

    Aslan, Lokman; Aslankurt, Murat; Aksoy, Adnan; Altun, Hatice

    2013-01-01

    To assess the preventable visual impairment in children with nonprofound intellectual disability (ID). 
 A total of 215 children with IDs (90 Down syndrome [DS], 125 nonprofound ID) and 116 age- and sex-matched healthy subjects were enrolled in this study. All participants underwent ophthalmologic examinations including cycloplegic refraction measurements, ocular movement evaluation, screening for strabismus (Hirschberg, Krimsky, or prism cover test), slit-lamp biomicroscopy, funduscopy, and intraocular pressure measurements. All data were recorded for statistical analysis.
 Ocular findings in decreasing prevalence were as follows: refractive errors 55 (61.1%), strabismus 30 (33.2%), cataract 7 (7.8%), and nystagmus 7 (7.8%) in children with DS; refractive errors 57 (45.6%), strabismus 19 (15.2%), cataract 7 (6.4%), nystagmus 5 (4%), and glaucoma 1 (0.8%) in children with other ID; and refractive errors 13 (11.2%) and strabismus 4 (3.5%) in controls. Cataracts, glaucoma, and nystagmus were not observed in the control group. The most common ophthalmic findings in children with DS compared with other ID and controls were with hyperopia (p<0.03 and 
p<0.001, respectively) and esotropia (p<0.01 and p<0.01, respectively).
 The pediatric population with ID has a high prevalence of preventable visual impairments, refractive errors, strabismus, and cataracts. The prevalence of strabismus and refractive errors was more frequent in children with DS. The importance of further health screenings including ophthalmic examinations should be utilized to implement appropriate care management and improve quality of life.

  18. Cycloplegic refraction is the gold standard for epidemiological studies.

    PubMed

    Morgan, Ian G; Iribarren, Rafael; Fotouhi, Akbar; Grzybowski, Andrzej

    2015-09-01

    Many studies on children have shown that lack of cycloplegia is associated with slight overestimation of myopia and marked errors in estimates of the prevalence of emmetropia and hyperopia. Non-cycloplegic refraction is particularly problematic for studies of associations with risk factors. The consensus around the importance of cycloplegia in children left undefined at what age, if any, cycloplegia became unnecessary. It was often implicitly assumed that cycloplegia is not necessary beyond childhood or early adulthood, and thus, the protocol for the classical studies of refraction in older adults did not include cycloplegia. Now that population studies of refractive error are beginning to fill the gap between schoolchildren and older adults, whether cycloplegia is required for measuring refractive error in this age range, needs to be defined. Data from the Tehran Eye Study show that, without cycloplegia, there are errors in the estimation of myopia, emmetropia and hyperopia in the age range 20-50, just as in children. Similar results have been reported in an analysis of data from the Beaver Dam Offspring Eye Study. If the only important outcome measure of a particular study is the prevalence of myopia, then cycloplegia may not be crucial in some cases. But, without cycloplegia, measurements of other refractive categories as well as spherical equivalent are unreliable. In summary, the current evidence suggests that cycloplegic refraction should be considered as the gold standard for epidemiological studies of refraction, not only in children, but in adults up to the age of 50. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Refractive regression after laser in situ keratomileusis.

    PubMed

    Yan, Mabel K; Chang, John Sm; Chan, Tommy Cy

    2018-04-26

    Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed. © 2018 Royal Australian and New Zealand College of Ophthalmologists.

  20. Refractive ocular conditions and reasons for spectacles renewal in a resource-limited economy

    PubMed Central

    2010-01-01

    Background Although a leading cause of visual impairment and a treatable cause of blindness globally, the pattern of refractive errors in many populations is unknown. This study determined the pattern of refractive ocular conditions, reasons for spectacles renewal and the effect of correction on refractive errors in a resource-limited community. Methods A retrospective review of case records of 1,413 consecutive patients seen in a private optometry practice, Nigeria between January 2006 and July 2007. Results A total number of 1,216 (86.1%) patients comprising of (486, 40%) males and (730, 60%) females with a mean age of 41.02 years SD 14.19 were analyzed. The age distribution peaked at peri-adolescent and the middle age years. The main ocular complaints were spectacles loss and discomfort (412, 33.9%), blurred near vision (399, 32.8%) and asthenopia (255, 20.9%). The mean duration of ocular symptoms before consultation was 2.05 years SD 1.92. The most common refractive errors include presbyopia (431, 35.3%), hyperopic astigmatism (240, 19.7%) and presbyopia with hyperopia (276, 22.7%). Only (59, 4.9%) had myopia. Following correction, there were reductions in magnitudes of the blind (VA<3/60) and visually impaired (VA<6/18-3/60) patients by (18, 58.1%) and (89, 81.7%) respectively. The main reasons for renewal of spectacles were broken lenses/frame/scratched lenses/lenses' falling off (47, 63.4%). Conclusions Adequate correction of refractive errors reduces visual impairment and avoidable blindness and to achieve optimal control of refractive errors in the community, services should be targeted at individuals in the peri-adolescent and the middle age years. PMID:20459676

  1. Refractive ocular conditions and reasons for spectacles renewal in a resource-limited economy.

    PubMed

    Ayanniyi, Abdulkabir A; Folorunso, Francisca N; Adepoju, Feyisayo G

    2010-05-07

    Although a leading cause of visual impairment and a treatable cause of blindness globally, the pattern of refractive errors in many populations is unknown. This study determined the pattern of refractive ocular conditions, reasons for spectacles renewal and the effect of correction on refractive errors in a resource-limited community. A retrospective review of case records of 1,413 consecutive patients seen in a private optometry practice, Nigeria between January 2006 and July 2007. A total number of 1,216 (86.1%) patients comprising of (486, 40%) males and (730, 60%) females with a mean age of 41.02 years SD 14.19 were analyzed. The age distribution peaked at peri-adolescent and the middle age years. The main ocular complaints were spectacles loss and discomfort (412, 33.9%), blurred near vision (399, 32.8%) and asthenopia (255, 20.9%). The mean duration of ocular symptoms before consultation was 2.05 years SD 1.92. The most common refractive errors include presbyopia (431, 35.3%), hyperopic astigmatism (240, 19.7%) and presbyopia with hyperopia (276, 22.7%). Only (59, 4.9%) had myopia. Following correction, there were reductions in magnitudes of the blind (VA<3/60) and visually impaired (VA<6/18-3/60) patients by (18, 58.1%) and (89, 81.7%) respectively. The main reasons for renewal of spectacles were broken lenses/frame/scratched lenses/lenses' falling off (47, 63.4%). Adequate correction of refractive errors reduces visual impairment and avoidable blindness and to achieve optimal control of refractive errors in the community, services should be targeted at individuals in the peri-adolescent and the middle age years.

  2. Self correction of refractive error among young people in rural China: results of cross sectional investigation

    PubMed Central

    Zhang, Mingzhi; Zhang, Riping; He, Mingguang; Liang, Wanling; Li, Xiaofeng; She, Lingbing; Yang, Yunli; MacKenzie, Graeme; Silver, Joshua D; Ellwein, Leon; Moore, Bruce

    2011-01-01

    Objective To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. Design Cross sectional study. Setting Rural southern China. Participants 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤6/12 in either eye. Interventions All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. Main outcome measures Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. Results Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P=0.033 for self refraction v automated refraction, P=0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P=0.001), and not having previously worn spectacles (P=0.002), but not age or sex. Significant inaccuracies in power (≥1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). Conclusions Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children’s vision programmes in rural China. PMID:21828207

  3. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    PubMed

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  4. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study.

    PubMed

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.

  5. Nondestructive measurement of the refractive index distribution of a glass molded lens by two-wavelength wavefronts.

    PubMed

    Sugimoto, Tomohiro

    2016-10-01

    This paper presents a nondestructive and non-exact-index-matching method for measuring the refractive index distribution of a glass molded lens with high refractivity. The method measures two-wavelength wavefronts of a test lens immersed in a liquid with a refractive index dispersion different from that of the test lens and calculates the refractive index distribution by eliminating the refractive index distribution error caused by the shape error of the test lens. The estimated uncertainties of the refractive index distributions of test lenses with nd≈1.77 and nd≈1.85 were 1.9×10-5  RMS and 2.4×10-5  RMS, respectively. I validated the proposed method by evaluating the agreement between the estimated uncertainties and experimental values.

  6. Visual symptoms associated with refractive errors among Thangka artists of Kathmandu valley.

    PubMed

    Dhungel, Deepa; Shrestha, Gauri Shankar

    2017-12-21

    Prolong near work, especially among people with uncorrected refractive error is considered a potential source of visual symptoms. The present study aims to determine the visual symptoms and the association of those with refractive errors among Thangka artists. In a descriptive cross-sectional study, 242 (46.1%) participants of 525 thangka artists examined, with age ranged between 16 years to 39 years which comprised of 112 participants with significant refractive errors and 130 absolutely emmetropic participants, were enrolled from six Thangka painting schools. The visual symptoms were assessed using a structured questionnaire consisting of nine items and scoring from 0 to 6 consecutive scales. The eye examination included detailed anterior and posterior segment examination, objective and subjective refraction, and assessment of heterophoria, vergence and accommodation. Symptoms were presented in percentage and median. Variation in distribution of participants and symptoms was analysed using the Kruskal Wallis test for mean, and the correlation with the Pearson correlation coefficient. A significance level of 0.05 was applied for 95% confidence interval. The majority of participants (65.1%) among refractive error group (REG) were above the age of 30 years, with a male predominance (61.6%), compared to the participants in the normal cohort group (NCG), where majority of them (72.3%) were below 30 years of age (72.3%) and female (51.5%). Overall, the visual symptoms are high among Thangka artists. However, blurred vision (p = 0.003) and dry eye (p = 0.004) are higher among the REG than the NCG. Females have slightly higher symptoms than males. Most of the symptoms, such as sore/aching eye (p = 0.003), feeling dry (p = 0.005) and blurred vision (p = 0.02) are significantly associated with astigmatism. Thangka artists present with significant proportion of refractive error and visual symptoms, especially among females. The most commonly reported symptoms are blurred vision, dry eye and watering of the eye. The visual symptoms are more correlated with astigmatism.

  7. Ametropias in school-age children in Fada N'Gourma (Burkina Faso, Africa).

    PubMed

    Jiménez, Raimundo; Soler, Margarita; Anera, Rosario G; Castro, José J; Pérez, M Angustias; Salas, Carlos

    2012-01-01

    To assess epidemiological aspects of refractive errors in school-age children in Burkina Faso (west-central Africa). A total of 315 school children (ranging from 6 to 16 years of age and belonging to different ethnic groups) taken at random from two urban schools in eastern Burkina Faso were examined to assess their refractive error, which was determined by non-cycloplegic retinoscopy with optical fogging. The standard Refractive Error Study in Children (RESC) definitions of refractive errors were used: myopia ≤-0.5 D spherical equivalent (SE) in at least one eye, hyperopia ≥2 D SE in at least one eye, astigmatism ≤-0.75 D cylinder in at least one eye, and anisometropia ≥1 D SE difference between the two eyes. Unilateral myopia and bilateral myopia were found in 2.5 and 1%, respectively; unilateral hyperopia in 17.1%, bilateral hyperopia in 8.6%; astigmatism in at least one eye in 11.7%. The highest prevalence value (18.4%) of astigmatism (≤-0.75 D) in at least one eye was found in the Gourmantché ethnic group. The low prevalence of large refractive errors makes visual acuity in these children very good (visual acuity logarithm of the minimum angle of resolution -0.073 ± 0.123 SD). There was a low prevalence of myopia in these African school children. Clinically significant high hyperopia (≥+2 D SE) was also uncommon. There were no significant differences between the distributions of refractive errors according to gender or ethnicity. With respect to age groups, the prevalences of hyperopia and astigmatism were significantly higher in the younger age groups.

  8. Wave aberrations in rhesus monkeys with vision-induced ametropias

    PubMed Central

    Ramamirtham, Ramkumar; Kee, Chea-su; Hung, Li-Fang; Qiao-Grider, Ying; Huang, Juan; Roorda, Austin; Smith, Earl L.

    2007-01-01

    The purpose of this study was to investigate the relationship between refractive errors and high-order aberrations in infant rhesus monkeys. Specifically, we compared the monochromatic wave aberrations measured with a Shack-Hartman wavefront sensor between normal monkeys and monkeys with vision-induced refractive errors. Shortly after birth, both normal monkeys and treated monkeys reared with optically induced defocus or form deprivation showed a decrease in the magnitude of high-order aberrations with age. However, the decrease in aberrations was typically smaller in the treated animals. Thus, at the end of the lens-rearing period, higher than normal amounts of aberrations were observed in treated eyes, both hyperopic and myopic eyes and treated eyes that developed astigmatism, but not spherical ametropias. The total RMS wavefront error increased with the degree of spherical refractive error, but was not correlated with the degree of astigmatism. Both myopic and hyperopic treated eyes showed elevated amounts of coma and trefoil and the degree of trefoil increased with the degree of spherical ametropia. Myopic eyes also exhibited a much higher prevalence of positive spherical aberration than normal or treated hyperopic eyes. Following the onset of unrestricted vision, the amount of high-order aberrations decreased in the treated monkeys that also recovered from the experimentally induced refractive errors. Our results demonstrate that high-order aberrations are influenced by visual experience in young primates and that the increase in high-order aberrations in our treated monkeys appears to be an optical byproduct of the vision-induced alterations in ocular growth that underlie changes in refractive error. The results from our study suggest that the higher amounts of wave aberrations observed in ametropic humans are likely to be a consequence, rather than a cause, of abnormal refractive development. PMID:17825347

  9. Prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in marine fishing communities in South India: Rapid Assessment of Visual Impairment (RAVI) project.

    PubMed

    Marmamula, Srinivas; Madala, Sreenivas R; Rao, Gullapalli N

    2012-03-01

    To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 40 years or more using a novel Rapid Assessment of Visual Impairment (RAVI) methodology. A population-based cross-sectional study was conducted using cluster random sampling to enumerate 1700 subjects from 34 clusters predominantly inhabited by marine fishing communities in the Prakasam district of Andhra Pradesh, India. Unaided, aided and pinhole visual acuity (VA) was assessed using a Snellen chart at a distance of 6 m. Near vision was assessed using an N notation chart. Uncorrected refractive error was defined as presenting VA < 6/18 and improving to ≥6/18 with pinhole. Uncorrected presbyopia was defined as binocular near vision worse than N8 in subjects with binocular distance VA ≥ 6/18. 1560 subjects (response rate - 92%) were available for examination. Of these, 54.6% were female and 10.1% were ≥70 years of age. Refractive error was present in 250 individuals. It was uncorrected in 179 (unmet need) and corrected in 71 (met need) individuals. Among 1094 individuals with no distance visual impairment, presbyopia was present in 494 individuals. It was uncorrected in 439 (unmet need) and corrected in 55 individuals (met need). Spectacle coverage was 28.4% for refractive errors and 11.1% for presbyopia. There is a high unmet need for uncorrected refractive errors and presbyopia among marine fishing communities in the Prakasam district of South India. The data from this study can now be used as a baseline prior to the commencement of eye care services in this region. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  10. Effects of Head-Mounted Display on the Oculomotor System and Refractive Error in Normal Adolescents.

    PubMed

    Ha, Suk-Gyu; Na, Kun-Hoo; Kweon, Il-Joo; Suh, Young-Woo; Kim, Seung-Hyun

    2016-07-01

    To investigate the clinical effects of head-mounted display on the refractive error and oculomotor system in normal adolescents. Sixty volunteers (age: 13 to 18 years) watched a three-dimensional movie and virtual reality application of head-mounted display for 30 minutes. The refractive error (diopters [D]), angle of deviation (prism diopters [PD]) at distance (6 m) and near (33 cm), near point of accommodation, and stereoacuity were measured before, immediately after, and 10 minutes after watching the head-mounted display. The refractive error was presented as spherical equivalent (SE). Refractive error was measured repeatedly after every 10 minutes when a myopic shift greater than 0.15 D was observed after watching the head-mounted display. The mean age of the participants was 14.7 ± 1.3 years and the mean SE before watching head-mounted display was -3.1 ± 2.6 D. One participant in the virtual reality application group was excluded due to motion sickness and nausea. After 30 minutes of watching the head-mounted display, the SE, near point of accommodation, and stereoacuity in both eyes did not change significantly (all P > .05). Immediately after watching the head-mounted display, esophoric shift was observed (0.6 ± 1.5 to 0.2 ± 1.5 PD), although it was not significant (P = .06). Transient myopic shifts of 17.2% to 30% were observed immediately after watching the head-mounted display in both groups, but recovered fully within 40 minutes after watching the head-mounted display. There were no significant clinical effects of watching head-mounted display for 30 minutes on the normal adolescent eye. Transient changes in refractive error and binocular alignment were noted, but were not significant. [J Pediatr Ophthalmol Strabismus. 2016;53(4):238-245.]. Copyright 2016, SLACK Incorporated.

  11. Prevalence of refractive errors and associated risk factors in subjects with type 2 diabetes mellitus SN-DREAMS, report 18.

    PubMed

    Rani, Padmaja Kumari; Raman, Rajiv; Rachapalli, Sudhir R; Kulothungan, Vaitheeswaran; Kumaramanickavel, Govindasamy; Sharma, Tarun

    2010-06-01

    To report the prevalence of refractive errors and the associated risk factors in subjects with type 2 diabetes mellitus from an urban Indian population. Population-based, cross-sectional study. One thousand eighty participants selected from a pool of 1414 subjects with diabetes. A population-based sample of 1414 persons (age >40 years) with diabetes (identified as per the World Health Organization criteria) underwent a comprehensive eye examination, including objective and subjective refractions. One thousand eighty subjects who were phakic in the right eye with best corrected visual acuity of > or =20/40 were included in the analysis for prevalence of refractive errors. Univariate and multivariate analyses were done to find out the independent risk factors associated with the refractive errors. The mean refraction was +0.20+/-1.72, and the Median, +0.25 diopters. The prevalence of emmetropia (spherical equivalent [SE], -0.50 to +0.50 diopter sphere [DS]) was 39.26%. The prevalence of myopia (SE <-0.50 DS), high myopia (SE <-5.00 DS), hyperopia (SE >+0.50 DS), and astigmatism (SE <-0.50 cyl) was 19.4%, 1.6%, 39.7%, and 47.4%, respectively. The advancing age was an important risk factor for the three refractive errors: for myopia, odds ratio (OR; 95% confidence interval [CI] 4.06 [1.74-9.50]; for hyperopia, OR [95% CI] 5.85 [2.56-13.39]; and for astigmatism, OR [95% CI] 2.51 [1.34-4.71]). Poor glycemic control was associated with myopia (OR [95% CI] 4.15 [1.44-11.92]) and astigmatism (OR [95% CI] 2.01 [1.04-3.88]). Female gender was associated with hyperopia alone) OR [95% CI] 2.00 [1.42-2.82]. The present population-based study from urban India noted a high prevalence of refractive errors (60%) among diabetic subjects >40 years old; the prevalence of astigmatism (47%) was higher than hyperopia (40%) or myopia (20%). Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Prognostic Factors Predicting the Surgical Outcomes of Bilateral Lateral Rectus Recession for Patients with Concomitant Exotropia in Chiang Mai University Hospital.

    PubMed

    Trakanwitthayarak, Supaporn; Patikulsila, Prapatsorn

    2017-01-01

    To determine the preoperative variables affecting early and late favorable outcomes of bilateral lateral rectus recession surgery for concomitant exotropia. A retrospective study of 65 patients with concomitant exotropia (constant and intermittent) who had bilateral lateral rectus recession was conducted. The follow-up period was more than 1 year in all patients. Preoperative parameters were obtained and evaluated using univariate analysis. Sixty-five patients with concomitant exotropia who underwent bilateral lateral rectus recession were included. In the early and late postoperative outcome, 78% and 82% of the patients were in the success group, respectively. Meanwhile, 22% and 18% were in the failure group, respectively. There was no association between postoperative outcome and preoperative variables i.e. age at onset (p = 0.841, 0.591), age at surgery (p = 0.564, 0.634), interval between onset and surgery (p = 0.506, 0.753), preoperative deviation (p = 0.278, 0.211), refractive error (p = 0.217, 0.136), anisometropia (p = 0.946, 0.946), phase of exotropia (p = 0.741, 0.013), A-V pattern (p = 1.000, 1.000), stereopsis (p = 0.841, 0.268) and amblyopia (p = 0.569, 0.567). Preoperative variables could not be used to predict the early and late postoperative outcome.

  13. Child Development and Refractive Errors in Preschool Children

    PubMed Central

    Ibironke, Josephine O.; Friedman, David S.; Repka, Michael X.; Katz, Joanne; Giordano, Lydia; Hawse, Patricia; Tielsch, James M.

    2011-01-01

    Purpose Many parents are concerned about their child's development. The purpose of this study is to determine if parental concerns about overall development are associated with significant refractive errors among urban preschool children. Methods A cross-sectional population-based study was conducted to evaluate the prevalence of ocular disorders in white and African American children 6 through 71 months of age in Baltimore, Maryland, United States. A comprehensive eye examination with cycloplegic refraction was performed. Parental concerns about development were measured with the Parents' Evaluation of Developmental Status screening tool. 2381 of 2546 eligible children (93.5%) completed the refraction and the parental interview. Results Parental concerns about development were present in 510 of the 2381 children evaluated (21.4%; 95% CI: 9.8% – 23.1%). The adjusted odds ratios [OR] of parental concerns with hyperopia (≥ 3.00D) was 1.26 (95% CI: 0.90 – 1.74), with myopia (≥ 1.00D) was 1.29 (95% CI: 0.83 – 2.03), with astigmatism (≥ 1.50D) was 1.44 (95% CI: 1.08 – 1.93) irrespective of the type of astigmatism, and with anisometropia ≥ 2.00D was 2.61 (95% CI: 1.07 – 6.34). The odds of parental concerns about development significantly increased in children older than 36 months with hyperopia ≥ 3.00D, astigmatism ≥ 1.50D, or anisometropia ≥ 2.00D. Conclusions Parental concerns about general developmental problems were associated with some types of refractive error, astigmatism ≥ 1.50D and anisometropia ≥ 2.00D in children ages 6 to 71 months. Parental concerns were also more likely in children older than 36 months of age with hypermetropia, astigmatism or anisometropia. Parental concerns were not associated with myopia. Due to the potential consequences of uncorrected refractive errors, children whose parents have expressed concerns regarding development should be referred for an eye examination with cycloplegic refraction to rule out significant refractive errors. PMID:21150680

  14. Studies of intrastromal corneal ring segments for the correction of low to moderate myopic refractive errors.

    PubMed Central

    Schanzlin, D J

    1999-01-01

    PURPOSE: Intrastromal corneal ring segments (ICRS) were investigated for safety and reliability in the correction of low to moderate myopic refractive errors. METHODS: Initially, 74 patients with spherical equivalent refractive errors between -1.00 and -4.25 diopters (D) received the ICRS in 1 eye. After 6 months, 51 of these patients received the ICRS in the contralateral eye. The total number of eyes investigated was 125. The outcome measures were uncorrected and best-corrected visual acuity, predictability and stability of the refraction, refractive astigmatism, contrast sensitivity, and endothelial cell morphology. RESULTS: The 89 eyes with 12-month follow-up showed significant improvement with uncorrected visual acuities of 20/16 or better in 37%, 20/20 or better in 62%, and 20/40 or better in 97%. Cycloplegic refraction spherical equivalents showed that 68% of the eyes were within +/- 0.50 D and 90% within +/- 1.00 D of the intended correction. Refractive stability was present by 3 months after the surgery. Only 1 patients had a loss greater than 2 lines or 10 letters of best spectacle-corrected visual acuity, but the patient's acuity was 20/20. Refractive cylinder, contrast sensitivity, and endothelial cell morphology were not adversely affected. The ICRS was removed from the eyes of 6 patients. Three removals were prompted by glare and double images occurring at night; 3 were for nonmedical reasons. All patients returned to within +/- 1.00 D of their preoperative refractive spherical equivalent, and no patients lost more than 1 line of best corrected visual acuity by 3 months after ICRS removal. CONCLUSION: The ICRS safely and reliably corrects myopic refractive errors between -1.00 and -4.50 D. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 PMID:10703146

  15. Genome-wide association meta-analysis highlights light-induced signaling as a driver for refractive error.

    PubMed

    Tedja, Milly S; Wojciechowski, Robert; Hysi, Pirro G; Eriksson, Nicholas; Furlotte, Nicholas A; Verhoeven, Virginie J M; Iglesias, Adriana I; Meester-Smoor, Magda A; Tompson, Stuart W; Fan, Qiao; Khawaja, Anthony P; Cheng, Ching-Yu; Höhn, René; Yamashiro, Kenji; Wenocur, Adam; Grazal, Clare; Haller, Toomas; Metspalu, Andres; Wedenoja, Juho; Jonas, Jost B; Wang, Ya Xing; Xie, Jing; Mitchell, Paul; Foster, Paul J; Klein, Barbara E K; Klein, Ronald; Paterson, Andrew D; Hosseini, S Mohsen; Shah, Rupal L; Williams, Cathy; Teo, Yik Ying; Tham, Yih Chung; Gupta, Preeti; Zhao, Wanting; Shi, Yuan; Saw, Woei-Yuh; Tai, E-Shyong; Sim, Xue Ling; Huffman, Jennifer E; Polašek, Ozren; Hayward, Caroline; Bencic, Goran; Rudan, Igor; Wilson, James F; Joshi, Peter K; Tsujikawa, Akitaka; Matsuda, Fumihiko; Whisenhunt, Kristina N; Zeller, Tanja; van der Spek, Peter J; Haak, Roxanna; Meijers-Heijboer, Hanne; van Leeuwen, Elisabeth M; Iyengar, Sudha K; Lass, Jonathan H; Hofman, Albert; Rivadeneira, Fernando; Uitterlinden, André G; Vingerling, Johannes R; Lehtimäki, Terho; Raitakari, Olli T; Biino, Ginevra; Concas, Maria Pina; Schwantes-An, Tae-Hwi; Igo, Robert P; Cuellar-Partida, Gabriel; Martin, Nicholas G; Craig, Jamie E; Gharahkhani, Puya; Williams, Katie M; Nag, Abhishek; Rahi, Jugnoo S; Cumberland, Phillippa M; Delcourt, Cécile; Bellenguez, Céline; Ried, Janina S; Bergen, Arthur A; Meitinger, Thomas; Gieger, Christian; Wong, Tien Yin; Hewitt, Alex W; Mackey, David A; Simpson, Claire L; Pfeiffer, Norbert; Pärssinen, Olavi; Baird, Paul N; Vitart, Veronique; Amin, Najaf; van Duijn, Cornelia M; Bailey-Wilson, Joan E; Young, Terri L; Saw, Seang-Mei; Stambolian, Dwight; MacGregor, Stuart; Guggenheim, Jeremy A; Tung, Joyce Y; Hammond, Christopher J; Klaver, Caroline C W

    2018-06-01

    Refractive errors, including myopia, are the most frequent eye disorders worldwide and an increasingly common cause of blindness. This genome-wide association meta-analysis in 160,420 participants and replication in 95,505 participants increased the number of established independent signals from 37 to 161 and showed high genetic correlation between Europeans and Asians (>0.78). Expression experiments and comprehensive in silico analyses identified retinal cell physiology and light processing as prominent mechanisms, and also identified functional contributions to refractive-error development in all cell types of the neurosensory retina, retinal pigment epithelium, vascular endothelium and extracellular matrix. Newly identified genes implicate novel mechanisms such as rod-and-cone bipolar synaptic neurotransmission, anterior-segment morphology and angiogenesis. Thirty-one loci resided in or near regions transcribing small RNAs, thus suggesting a role for post-transcriptional regulation. Our results support the notion that refractive errors are caused by a light-dependent retina-to-sclera signaling cascade and delineate potential pathobiological molecular drivers.

  16. Correct consideration of the index of refraction using blackbody radiation.

    PubMed

    Hartmann, Jurgen

    2006-09-04

    The correct consideration of the index of refraction when using blackbody radiators as standard sources for optical radiation is derived and discussed. It is shown that simply using the index of refraction of air at laboratory conditions is not sufficient. A combination of the index of refraction of the media used inside the blackbody radiator and for the optical path between blackbody and detector has to be used instead. A worst case approximation for the introduced error when neglecting these effects is presented, showing that the error is below 0.1 % for wavelengths above 200 nm. Nevertheless, for the determination of the spectral radiance for the purpose of radiation temperature measurements the correct consideration of the refractive index is mandatory. The worst case estimation reveals that the introduced error in temperature at a blackbody temperature of 3000 degrees C can be as high as 400 mk at a wavelength of 650 nm and even higher at longer wavelengths.

  17. Femtosecond laser-assisted LASIK versus PRK for high myopia: comparison of 18-month visual acuity and quality.

    PubMed

    Hashemi, Hassan; Ghaffari, Reza; Miraftab, Mohammad; Asgari, Soheila

    2017-08-01

    To compare 18-month outcomes between femtosecond laser-assisted LASIK (femto-LASIK) and photorefractive keratectomy with mitomycin-C (PRK-MMC) for myopia of more than 7.0 D in terms of visual acuity and quality. In this comparative nonrandomized clinical trial, 60 eyes from 30 patients (30 eyes in each group) were enrolled. The two procedures were compared in terms of 18-month changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal higher order aberrations (HOAs), and contrast sensitivity (CS). Mean myopia was -8.65 ± 1.51 and -8.04 ± 1.70 D (P = 0.149) and mean ablation depth was 109.37 ± 9.07 and 105.09 ± 12.59 µm (P = 0.138), in the femto-LASIK and PRK-MMC groups, respectively. Baseline parameters were not significantly different between the two groups (all P > 0.05). At 18 months postoperatively, 75 % in the femto-LASIK, versus 57.1 % in the PRK-MMC group, had 20/20 UDVA (P = 0.017). CDVA remained similarly unchanged in both groups (P = 0.616). No case had residual refractive error more than 1.0 D in the femto-LASIK group, while 33.5 % in the other group had more than 1.0 D residual error (P = 0.390). Changes in corneal HOA were not significantly different between the two groups (P = 0.260). Cases in the femto-LASIK group showed more increase in ocular HOA (P = 0.032) and coma (P = 0.083, power = 72 %). CS remained similarly unchanged in all spatial frequencies in both groups (all P > 0.05). Although femto-LASIK induces more HOA compared to PRK-MMC, considering outcomes in terms of 20/20 UDVA, residual refractive error, and CS stability, femto-LASIK provides more favorable results than PRK-MMC in high myopia.

  18. Effect of Orthokeratology on myopia progression: twelve-year results of a retrospective cohort study.

    PubMed

    Lee, Yueh-Chang; Wang, Jen-Hung; Chiu, Cheng-Jen

    2017-12-08

    Several studies reported the efficacy of orthokeratology for myopia control. Somehow, there is limited publication with follow-up longer than 3 years. This study aims to research whether overnight orthokeratology influences the progression rate of the manifest refractive error of myopic children in a longer follow-up period (up to 12 years). And if changes in progression rate are found, to investigate the relationship between refractive changes and different baseline factors, including refraction error, wearing age and lens replacement frequency. In addition, this study collects long-term safety profile of overnight orthokeratology. This is a retrospective study of sixty-six school-age children who received overnight orthokeratology correction between January 1998 and December 2013. Thirty-six subjects whose baseline age and refractive error matched with those in the orthokeratology group were selected to form control group. These subjects were followed up at least for 12 months. Manifest refractions, cycloplegic refractions, uncorrected and best-corrected visual acuities, power vector of astigmatism, corneal curvature, and lens replacement frequency were obtained for analysis. Data of 203 eyes were derived from 66 orthokeratology subjects (31 males and 35 females) and 36 control subjects (22 males and 14 females) enrolled in this study. Their wearing ages ranged from 7 years to 16 years (mean ± SE, 11.72 ± 0.18 years). The follow-up time ranged from 1 year to 13 years (mean ± SE, 6.32 ± 0.15 years). At baseline, their myopia ranged from -0.5 D to -8.0 D (mean ± SE, -3.70 ± 0.12 D), and astigmatism ranged from 0 D to -3.0 D (mean ± SE, -0.55 ± 0.05 D). Comparing with control group, orthokeratology group had a significantly (p < 0.001) lower trend of refractive error change during the follow-up periods. According to the analysis results of GEE model, greater power of astigmatism was found to be associated with increased change of refractive error during follow-up years. Overnight orthokeratology was effective in slowing myopia progression over a twelve-year follow-up period and demonstrated a clinically acceptable safety profile. Initial higher astigmatism power was found to be associated with increased change of refractive error during follow-up years.

  19. [Improvement of vision through perceptual learning in the case of refractive errors and presbyopia : A critical valuation].

    PubMed

    Heinrich, S P

    2017-02-01

    The idea of compensating or even rectifying refractive errors and presbyopia with the help of vision training is not new. For most approaches, however, scientific evidence is insufficient. A currently promoted method is "perceptual learning", which is assumed to improve stimulus processing in the brain. The basic phenomena of perceptual learning have been demonstrated by a multitude of studies. Some of these specifically address the case of refractive errors and presbyopia. However, many open questions remain, in particular with respect to the transfer of practice effects to every-day vision. At present, the method should therefore be judged with caution.

  20. Determining Nanoparticle Inhalation Exposure in the Prosthetics Laboratory at Walter Reed National Military Medical Center

    DTIC Science & Technology

    2013-04-29

    monotonic for particles sized between 500 and 1500 nm. There is also a response error for different refractive indexes of particles (59). In addition, all...accuracy when a range of refractive indexes is present. Detector response error ranges from 50-100%, depending on the refractive index present (17...Respiratory Diseases. Journal of American Medical Association 295 1127-33 13. Eftim E, Samet J, anes H, McDermott A, Dominici F. 2008. Fine

  1. Visual Survey of Infantry Troops. Part 1. Visual Acuity, Refractive Status, Interpupillary Distance and Visual Skills

    DTIC Science & Technology

    1989-06-01

    letters on one line and several letters on the next line, there is no accurate way to credit these extra letters for statistical analysis. The decimal and...contains the descriptive statistics of the objective refractive error components of infantrymen. Figures 8-11 show the frequency distributions for sphere...equivalents. Nonspectacle wearers Table 12 contains the idescriptive statistics for non- spectacle wearers. Based or these refractive error data, about 30

  2. The inverse problem of refraction travel times, part II: Quantifying refraction nonuniqueness using a three-layer model

    USGS Publications Warehouse

    Ivanov, J.; Miller, R.D.; Xia, J.; Steeples, D.

    2005-01-01

    This paper is the second of a set of two papers in which we study the inverse refraction problem. The first paper, "Types of Geophysical Nonuniqueness through Minimization," studies and classifies the types of nonuniqueness that exist when solving inverse problems depending on the participation of a priori information required to obtain reliable solutions of inverse geophysical problems. In view of the classification developed, in this paper we study the type of nonuniqueness associated with the inverse refraction problem. An approach for obtaining a realistic solution to the inverse refraction problem is offered in a third paper that is in preparation. The nonuniqueness of the inverse refraction problem is examined by using a simple three-layer model. Like many other inverse geophysical problems, the inverse refraction problem does not have a unique solution. Conventionally, nonuniqueness is considered to be a result of insufficient data and/or error in the data, for any fixed number of model parameters. This study illustrates that even for overdetermined and error free data, nonlinear inverse refraction problems exhibit exact-data nonuniqueness, which further complicates the problem of nonuniqueness. By evaluating the nonuniqueness of the inverse refraction problem, this paper targets the improvement of refraction inversion algorithms, and as a result, the achievement of more realistic solutions. The nonuniqueness of the inverse refraction problem is examined initially by using a simple three-layer model. The observations and conclusions of the three-layer model nonuniqueness study are used to evaluate the nonuniqueness of more complicated n-layer models and multi-parameter cell models such as in refraction tomography. For any fixed number of model parameters, the inverse refraction problem exhibits continuous ranges of exact-data nonuniqueness. Such an unfavorable type of nonuniqueness can be uniquely solved only by providing abundant a priori information. Insufficient a priori information during the inversion is the reason why refraction methods often may not produce desired results or even fail. This work also demonstrates that the application of the smoothing constraints, typical when solving ill-posed inverse problems, has a dual and contradictory role when applied to the ill-posed inverse problem of refraction travel times. This observation indicates that smoothing constraints may play such a two-fold role when applied to other inverse problems. Other factors that contribute to inverse-refraction-problem nonuniqueness are also considered, including indeterminacy, statistical data-error distribution, numerical error and instability, finite data, and model parameters. ?? Birkha??user Verlag, Basel, 2005.

  3. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    PubMed

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  4. Long-term follow-up of acute isolated accommodation insufficiency.

    PubMed

    Lee, Jung Jin; Baek, Seung-Hee; Kim, Ungsoo Samuel

    2013-04-01

    To define the long-term results of accommodation insufficiency and to investigate the correlation between accommodation insufficiency and other factors including near point of convergence (NPC), age, and refractive errors. From January 2008 to December 2009, 11 patients with acute near vision disturbance and remote near point of accommodation (NPA) were evaluated. Full ophthalmologic examinations, including best corrected visual acuity, manifest refraction and prism cover tests were performed. Accommodation ability was measured by NPA using the push-up method. We compared accommodation insufficiency and factors including age, refractive errors and NPC. We also investigated the recovery from loss of accommodation in patients. Mean age of patients was 20 years (range, 9 to 34 years). Five of the 11 patients were female. Mean refractive error was -0.6 diopters (range, -3.5 to +0.25 diopters) and 8 of 11 patients (73%) had emmetropia (+0.50 to -0.50 diopters). No abnormalities were found in brain imaging tests. Refractive errors were not correlated with NPA or NPC (rho = 0.148, p = 0.511; rho = 0.319, p = 0.339; respectively). The correlation between age and NPA was not significant (rho = -395, p = 0.069). However, the correlation between age and NPC was negative (rho = -0.508, p = 0.016). Three of 11 patients were lost to follow-up, and 6 of 8 patients had permanent insufficiency of accommodation. Accommodation insufficiency is most common in emmetropia, however, refractive errors and age are not correlated with accommodation insufficiency. Dysfunction of accommodation can be permanent in the isolated accommodation insufficiency.

  5. Long-term Follow-up of Acute Isolated Accommodation Insufficiency

    PubMed Central

    Lee, Jung Jin; Baek, Seung-Hee

    2013-01-01

    Purpose To define the long-term results of accommodation insufficiency and to investigate the correlation between accommodation insufficiency and other factors including near point of convergence (NPC), age, and refractive errors. Methods From January 2008 to December 2009, 11 patients with acute near vision disturbance and remote near point of accommodation (NPA) were evaluated. Full ophthalmologic examinations, including best corrected visual acuity, manifest refraction and prism cover tests were performed. Accommodation ability was measured by NPA using the push-up method. We compared accommodation insufficiency and factors including age, refractive errors and NPC. We also investigated the recovery from loss of accommodation in patients. Results Mean age of patients was 20 years (range, 9 to 34 years). Five of the 11 patients were female. Mean refractive error was -0.6 diopters (range, -3.5 to +0.25 diopters) and 8 of 11 patients (73%) had emmetropia (+0.50 to -0.50 diopters). No abnormalities were found in brain imaging tests. Refractive errors were not correlated with NPA or NPC (rho = 0.148, p = 0.511; rho = 0.319, p = 0.339; respectively). The correlation between age and NPA was not significant (rho = -395, p = 0.069). However, the correlation between age and NPC was negative (rho = -0.508, p = 0.016). Three of 11 patients were lost to follow-up, and 6 of 8 patients had permanent insufficiency of accommodation. Conclusions Accommodation insufficiency is most common in emmetropia, however, refractive errors and age are not correlated with accommodation insufficiency. Dysfunction of accommodation can be permanent in the isolated accommodation insufficiency. PMID:23543051

  6. Prevalence of Refractive Errors in Students with and without Color Vision Deficiency

    PubMed Central

    Ostadimoghaddam, Hadi; Yekta, Abbas Ali; Heravian, Javad; Azimi, Abbas; Hosseini, Seyed Mahdi Ahmadi; Vatandoust, Sakineh; Sharifi, Fatemeh; Abolbashari, Fereshteh

    2014-01-01

    Purpose: To evaluate refractive errors in school age children with color vision deficiency (CVD) and those with normal color vision (NCV) in order to make a better understanding of the emmetropization process. Methods: A total of 4,400 primary school students aged 7–12 years were screened for color vision using Ishihara pseudoisochromatic color vision plate sets. Of these, 160 (3.6%) students had CVD. A total of 400 age- and sex-matched students with NCV were selected as controls. Refractive status was evaluated using objective cyclorefraction. Results: The CVD group included 136 male (85%) and 24 female (15%) subjects with mean age of 10.1 ± 1.8 years. The NCV group comprised of 336 male (84%) and 64 female (16%) subjects with mean age of 10.5 ± 1.2 years. The prevalence of myopia (7.7% vs. 13.9%, P < 0.001) and hyperopia (41% vs. 57.4%, P = 0.03) was significantly lower in the CVD group. Furthermore, subjects with CVD subjects demonstrated a lower magnitude of refractive errors as compared to the CVD group (mean refractive error: +0.54 ± 0.19 D versus + 0.74 ± 1.12 D, P < 0.001). Conclusion: Although the lower prevalence of myopia in subjects with CVD group supports the role of longitudinal chromatic aberration in the development of refractive errors; the lower prevalence of hyperopia in this group is an opposing finding. Myopia is a multifactorial disorder and longitudinal chromatic aberration is not the only factor influencing the emmetropization process. PMID:25709775

  7. Small refractive errors--their correction and practical importance.

    PubMed

    Skrbek, Matej; Petrová, Sylvie

    2013-04-01

    Small refractive errors present a group of specifc far-sighted refractive dispositions that are compensated by enhanced accommodative exertion and aren't exhibited by loss of the visual acuity. This paper should answer a few questions about their correction, flowing from theoretical presumptions and expectations of this dilemma. The main goal of this research was to (dis)confirm the hypothesis about convenience, efficiency and frequency of the correction that do not raise the visual acuity (or if the improvement isn't noticeable). The next goal was to examine the connection between this correction and other factors (age, size of the refractive error, etc.). The last aim was to describe the subjective personal rating of the correction of these small refractive errors, and to determine the minimal improvement of the visual acuity, that is attractive enough for the client to purchase the correction (glasses, contact lenses). It was confirmed, that there's an indispensable group of subjects with good visual acuity, where the correction is applicable, although it doesn't improve the visual acuity much. The main importance is to eliminate the asthenopia. The prime reason for acceptance of the correction is typically changing during the life, so as the accommodation is declining. Young people prefer the correction on the ground of the asthenopia, caused by small refractive error or latent strabismus; elderly people acquire the correction because of improvement of the visual acuity. Generally the correction was found useful in more than 30%, if the gain of the visual acuity was at least 0,3 of the decimal row.

  8. Calculation of Ophthalmic Viscoelastic Device–Induced Focus Shift During Femtosecond Laser–Assisted Cataract Surgery

    PubMed Central

    de Freitas, Carolina P.; Cabot, Florence; Manns, Fabrice; Culbertson, William; Yoo, Sonia H.; Parel, Jean-Marie

    2015-01-01

    Purpose. To assess if a change in refractive index of the anterior chamber during femtosecond laser-assisted cataract surgery can affect the laser beam focus position. Methods. The index of refraction and chromatic dispersion of six ophthalmic viscoelastic devices (OVDs) was measured with an Abbe refractometer. Using the Gullstrand eye model, the index values were used to predict the error in the depth of a femtosecond laser cut when the anterior chamber is filled with OVD. Two sources of error produced by the change in refractive index were evaluated: the error in anterior capsule position measured with optical coherence tomography biometry and the shift in femtosecond laser beam focus depth. Results. The refractive indices of the OVDs measured ranged from 1.335 to 1.341 in the visible light (at 587 nm). The error in depth measurement of the refilled anterior chamber ranged from −5 to +7 μm. The OVD produced a shift of the femtosecond laser focus ranging from −1 to +6 μm. Replacement of the aqueous humor with OVDs with the densest compound produced a predicted error in cut depth of 13 μm anterior to the expected cut. Conclusions. Our calculations show that the change in refractive index due to anterior chamber refilling does not sufficiently shift the laser beam focus position to cause the incomplete capsulotomies reported during femtosecond laser–assisted cataract surgery. PMID:25626971

  9. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    PubMed

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  10. [LenSx® femto-LASIK, FEMTO LDV Z4® femto-LASIK, and PRK : Comparison of refractive results and an analysis of complications].

    PubMed

    Pahlitzsch, T; Pahlitzsch, M-L; Sumarni, U; Pahlitzsch, M

    2017-10-30

    The aim of this study is to evaluate three refractive procedures: LenSx® (Alcon, Fort Worth, TX, USA) femto-laser in situ keratomileusis (LASIK), FEMTO LDV Z4® (Ziemer, Port, Switzerland) femto-LASIK, and photorefractive keratectomy (PRK) in terms of refractive outcome, perioperative complications, pain, and patient satisfaction. Data of 168 eyes (myopic n = 84) were included in this retrospective study. Of these, 54 eyes (n = 27, 33.85 ± 7.64 years) were treated with LenSx® femto-LASIK, 60 eyes (n = 30, 35.03 ± 7.46 years) with FEMTO LDV Z4® femto-LASIK, and 54 eyes (n = 27, 33.24 ± 8.52 years) with PRK. Photoablation was induced by a MEL80 Excimerlaser (Zeiss, Oberkochen, Germany). The corrected (V sc ) and uncorrected (V cc ) distance subjective visual acuity, corneal topography (Pentacam® HR; Wetzlar, Germany), and objective astigmatism (ARK-760A Refractometer ; Nidek, Fremont, CA, USA) were measured preoperatively, and 1 day, 1 week, 1 month, and 3 months postoperatively. Subjective pain (verbal rating scale) and patient satisfaction were also recorded. Subjective V sc showed significantly better results in both femto-LASIK cohorts compared to PRK (p < 0.05) 1 day and 1 week postoperatively. There was no significant difference between the groups in terms of spherical equivalent and astigmatism 3 months postoperatively. The LenSx® femto-LASIK caused flap complications. The highest patient satisfaction results were shown in the LDV Z4® group, followed by the LenSx® and PRK cohorts (p = 0.072). LDV Z4® femto-LASIK showed the lowest pain score 1 day postoperatively (p < 0.001). There was no significant correlation between target refraction and preoperative corneal thickness and astigmatism. Femtosecond laser-assisted LASIK is an effective procedure enabling rapid rehabilitation of visual acuity with low postoperative pain compared to PRK. There is no difference between the three techniques regarding refractive outcome after 3 months follow-up. LDV Z4® femto-LASIK can be recommended, if available, due to its low intraoperative complication rate and higher patient satisfaction compared to LenSx® femto-LASIK.

  11. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed

    Hastings, Gareth D; Marsack, Jason D; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A

    2017-05-01

    To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ± S.D. was -0.06 ± 0.04 with both refractions; dilated was -0.05 ± 0.04 with the objective, and -0.05 ± 0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  12. Refractive lenticule extraction small incision lenticule extraction: A new refractive surgery paradigm

    PubMed Central

    Ganesh, Sri; Brar, Sheetal; Arra, Raghavender Reddy

    2018-01-01

    Small incision lenticule extraction (SMILE), a variant of refractive lenticule extraction technology is becoming increasingly popular, as a flapless and minimally invasive form of laser vision correction (LVC) for the treatment of myopia and myopic astigmatism. This review aims at summarizing the principles, surgical technique, and clinical outcomes in terms of visual and refractive results, safety, efficacy, postoperative dry eye, aberrations, and biomechanics of SMILE and its comparison with other conventional techniques of LVC, such as laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK). Recent advancements in the laser frequency and energy delivery patterns, instrumentation, and surgical techniques have shown significant improvement in the visual recovery and outcomes after SMILE, compared to the initial results published by Sekundo and Shah et al. Most of the recently published literature on long-term outcomes of SMILE shows excellent stability of the procedure, especially for higher myopia. In terms of the postoperative dry eye, SMILE shows a clear advantage over LASIK as numerous studies have shown significant differences about the Schirmer's, Tear film break up time, corneal sensitivity, and corneal nerve regeneration to be better following SMILE compared to LASIK. There is some evidence that since the Bowman's membrane (BM) and the anterior lamellae remain intact after SMILE, this may be a potential advantage for corneal biomechanics over LASIK and PRK where the BM is either severed or ablated, respectively, however, the data on biomechanics are inconclusive at present. Overall, this procedure has proved to be promising, delivering equivalent, or better visual and refractive results to LASIK and providing clear advantage in terms of being a flapless, minimally invasive procedure with minimal pain and postoperative discomfort thus offering high patient satisfaction. PMID:29283117

  13. The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 3: the results of 50 treated eyes.

    PubMed

    Motwani, Manoj

    2017-01-01

    To demonstrate how using the Wavelight Contoura measured astigmatism and axis eliminates corneal astigmatism and creates uniformly shaped corneas. A retrospective analysis was conducted of the first 50 eyes to have bilateral full WaveLight ® Contoura LASIK correction of measured astigmatism and axis (vs conventional manifest refraction), using the Layer Yolked Reduction of Astigmatism Protocol in all cases. All patients had astigmatism corrected, and had at least 1 week of follow-up. Accuracy to desired refractive goal was assessed by postoperative refraction, aberration reduction via calculation of polynomials, and postoperative visions were analyzed as a secondary goal. The average difference of astigmatic power from manifest to measured was 0.5462D (with a range of 0-1.69D), and the average difference of axis was 14.94° (with a range of 0°-89°). Forty-seven of 50 eyes had a goal of plano, 3 had a monovision goal. Astigmatism was fully eliminated from all but 2 eyes, and 1 eye had regression with astigmatism. Of the eyes with plano as the goal, 80.85% were 20/15 or better, and 100% were 20/20 or better. Polynomial analysis postoperatively showed that at 6.5 mm, the average C3 was reduced by 86.5% and the average C5 by 85.14%. Using WaveLight ® Contoura measured astigmatism and axis removes higher order aberrations and allows for the creation of a more uniform cornea with accurate removal of astigmatism, and reduction of aberration polynomials. WaveLight ® Contoura successfully links the refractive correction layer and aberration repair layer using the Layer Yolked Reduction of Astigmatism Protocol to demonstrate how aberration removal can affect refractive correction.

  14. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    NASA Astrophysics Data System (ADS)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.

  15. Retrieving the Vertical Structure of the Effective Aerosol Complex Index of Refraction from a Combination of Aerosol in Situ and Remote Sensing Measurements During TARFOX

    NASA Technical Reports Server (NTRS)

    Redemann, J.; Turco, R. P.; Liou, K. N.; Russell, P. B.; Bergstrom, R. W.; Schmid, B.; Livingston, J. M.; Hobbs, P. V.; Hartley, W. S.; Ismail, S.

    2000-01-01

    The largest uncertainty in estimates of the effects of atmospheric aerosols on climate stems from uncertainties in the determination of their microphysical properties, including the aerosol complex index of refraction, which in turn determines their optical properties. A novel technique is used to estimate the aerosol complex index of refraction in distinct vertical layers from a combination of aerosol in situ size distribution and remote sensing measurements during the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX). In particular, aerosol backscatter measurements using the NASA Langley LASE (Lidar Atmospheric Sensing Experiment) instrument and in situ aerosol size distribution data are utilized to derive vertical profiles of the 'effective' aerosol complex index of refraction at 815 nm (i.e., the refractive index that would provide the same backscatter signal in a forward calculation on the basis of the measured in situ particle size distributions for homogeneous, spherical aerosols). A sensitivity study shows that this method yields small errors in the retrieved aerosol refractive indices, provided the errors in the lidar derived aerosol backscatter are less than 30% and random in nature. Absolute errors in the estimated aerosol refractive indices are generally less than 0.04 for the real part and can be as much as 0.042 for the imaginary part in the case of a 30% error in the lidar-derived aerosol backscatter. The measurements of aerosol optical depth from the NASA Ames Airborne Tracking Sunphotometer (AATS-6) are successfully incorporated into the new technique and help constrain the retrieved aerosol refractive indices. An application of the technique to two TARFOX case studies yields the occurrence of vertical layers of distinct aerosol refractive indices. Values of the estimated complex aerosol refractive index range from 1.33 to 1.45 for the real part and 0.001 to 0.008 for the imaginary part. The methodology devised in this study provides, for the first time a complete set of vertically resolved aerosol size distribution and refractive index data, yielding the vertical distribution of aerosol optical properties required for the determination of aersol-induced radiative flux changes

  16. Retrieving the Vertical Structure of the Effective Aerosol Complex Index of Refraction from a Combination of Aerosol in Situ and Remote Sensing Measurements During TARFOX

    NASA Technical Reports Server (NTRS)

    Redemann, J.; Turco, R. P.; Liou, K. N.; Russell, P. B.; Bergstrom, R. W.; Schmid, B.; Livingston, J. M.; Hobbs, P. V.; Hartley, W. S.; Ismail, S.; hide

    2000-01-01

    The largest uncertainty in estimates of the effects of atmospheric aerosols on climate stems from uncertainties in the determination of their microphysical properties, including the aerosol complex index of refraction, which in turn determines their optical properties. A novel technique is used to estimate the aerosol complex index of refraction in distinct vertical layers from a combination of aerosol in situ size distribution and remote sensing measurements during the Tropospheric Aerosol Radiative Forcing Observational Experiment (TARFOX). In particular, aerosol backscatter measurements using the NASA Langley LASE (Lidar Atmospheric Sensing Experiment) instrument and in situ aerosol size distribution data are utilized to derive vertical profiles of the "effective" aerosol complex index of refraction at 815 nm (i.e., the refractive index that would provide the same backscatter signal in a forward calculation on the basis of the measured in situ particle size distributions for homogeneous, spherical aerosols). A sensitivity study shows that this method yields small errors in the retrieved aerosol refractive indices, provided the errors in the lidar-derived aerosol backscatter are less than 30% and random in nature. Absolute errors in the estimated aerosol refractive indices are generally less than 0.04 for the real part and can be as much as 0.042 for the imaginary part in the case of a 30% error in the lidar-derived aerosol backscatter. The measurements of aerosol optical depth from the NASA Ames Airborne Tracking Sunphotometer (AATS-6) are successfully incorporated into the new technique and help constrain the retrieved aerosol refractive indices. An application of the technique to two TARFOX case studies yields the occurrence of vertical layers of distinct aerosol refractive indices. Values of the estimated complex aerosol refractive index range from 1.33 to 1.45 for the real part and 0.001 to 0.008 for the imaginary part. The methodology devised in this study provides, for the first time, a complete set of vertically resolved aerosol size distribution and refractive index data. yielding the vertical distribution of aerosol optical properties required for the determination of aerosol-induced radiative flux changes.

  17. [Incidence of refractive errors with corrective aids subsequent selection].

    PubMed

    Benes, P; Synek, S; Petrová, S; Sokolová, Sidlová J; Forýtková, L; Holoubková, Z

    2012-02-01

    This study follows the occurrence of refractive errors in population and the possible selection of the appropriate type of corrective aids. Objective measurement and subsequent determination of the subjective refraction of the eye is on essential act in opotmetric practice. The file represented by 615 patients (1230 eyes) is divided according to the refractive error of myopia, hyperopia and as a control group are listed emetropic clients. The results of objective and subjective values of refraction are compared and statistically processed. The study included 615 respondents. To determine the objective refraction the autorefraktokeratometer with Placido disc was used and the values of spherical and astigmatic correction components, including the axis were recorded. These measurements were subsequently verified and tested subjectively using the trial lenses and the projection optotype to the normal investigative distance of 5 meters. After this the appropriate corrective aids were then recommended. Group I consists of 123 men and 195 women with myopia (n = 635) of clients with an average age 39 +/- 18,9 years. Objective refraction - sphere: -2,57 +/- 2,46 D, cylinder: -1,1 +/- 1,01 D, axis of: 100 degrees +/- 53,16 degrees. Subjective results are as follows--the value of sphere: -2,28 +/- 2,33 D, cylinder -0,63 +/- 0,80 D, axis of: 99,8 degrees +/- 56,64 degrees. Group II is represented hyperopic clients and consists of 67 men and 107 women (n = 348). The average age is 58,84 +/- 16,73 years. Objective refraction has values - sphere: +2,81 +/- 2,21 D, cylinder: -1,0 +/- 0,94 D; axis 95 degree +/- 45,4 degrees. Subsequent determination of subjective refraction has the following results - sphere: +2,28 +/- 2,06 D; cylinder: -0,49 +/- 0,85 D, axis of: 95,9 degrees +/- 46,4 degrees. Group III consists from emetropes whose final minimum viasual acuity was Vmin = 1,0 (5/5) or better. Overall, this control group is represented 52 males and 71 females (n = 247). The average age was 43 +/- 18,73 years. Objective refraction - sphere: +0,32 +/- 0,45 D; cylinder: -0,51 +/- 0,28 D, axis of: 94,7 degrees +/- 57,5 degrees. Values of objective refraction take higher values than the subsequent execution of the subjective examination of the refractive error and recommendation of the appropriate type of corrective aids. This all is in examined groups and in the individual components of refractive errors. It also confirmed the hypothesis that the population outweighs with-the-rule astigmatism, the deployment of resources according to the literature ranges from 90 degrees +/- 10 degrees. The values observed correction of refractive errors are then derived also offer the most common prescription ranges and products for the correction of given ametropia. In the selection and design corrective aids, we are often limited. Our task is then to manufacture high quality, functional and aesthetic corrective aids, you need to connect knowledge from the fields of optics, optometry and ophthalmology. Faster visual rehabilitation simplifies clients' rapid return to everyday life.

  18. The Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study

    PubMed Central

    He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun

    2017-01-01

    Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313

  19. [Clinical observation on corneal transparency after small incision lenticule extraction surgery].

    PubMed

    Zhang, L; Wang, Y; Cui, T; Zhao, W; Cheng, W B

    2018-01-11

    Objective: To evaluate the changes of corneal transparency over the 1-year period after small incision lenticule extraction (SMILE) according to corneal Scheimpflug densitometry. Methods: Prospective cohort study. Fifty-five patients (100 eyes) with myopia (19 male and 36 female, aged 18 to 39 years with average of 24) who underwent SMILE and regular follow-up for at least 1 year at Tianjin Eye Hospital were enrolled. Examinations took place before SMILE and postoperatively at 1 day, 1 week, and 1, 3, 6, and 12 months. The preoperative spherical equivalent of surgical refractive correction was (-5.75±1.64) D. Corneal densitometry (CD) data were calculated automatically by the Pentacam Scheimpflug system and expressed in gray scale units (GSU), from 0 (completely transparent) to 100 (completely opaque). During the analysis of corneal densitometry, the average corneal optical density of three concentric radial zones centered on the apex of the cornea ≤2 mm, >2 mm and ≤6 mm, >6 mm and ≤10 mm diameter) were applied, and three layers were defined according to different corneal depths (the anterior 120 μm as 1st layer, and the posterior 60 μm as 3rd layer, and the center part between them of the cornea as 2nd layer). The automatic release mode was applied in order to avoid operator-induced errors. The preoperative and postoperative values in different corneal layers and different concentric radial zones were compared using Kruskal-Wallis. Results: Ninty-three eyes(93%) of all eyes achieved uncorrected distance visual acuity (UCVA) of 0.8 or better on the first day postoperatively, and 96% (96 of 100 eyes) achieved UCVA of 0.8 or better in the first week postoperatevely, and all eyes 100% (100 of 100 eyes) achieved UCVA 0.8 or better until the end of our follow-up (in 1 year postoperatively). In general, the difference preoperative and postoperative corneal average optical density is of no statistical significance (χ(2)=8.446, P =0.207), specifically, the overall postoperative CD increased in the first week after surgery (1 day to 15.90, 1 week to 15.65), and then decreased to the equivalent of baseline levels and maintained such level until 6 months after surgery (1 month to 15.60; 3 month to 15.50, 6 month to 15.55), though at the 12-month follow-up, densitometry values had spiked significantly again (12 month, 15.90). The difference between the preoperative and postoperative CD values in the central two zones (≤2 mm, >2 mm and ≤6 mm), but not the outer (>6 mm and ≤10 mm), were of statistical significance (χ(2)=61.961, 52.397, P< 0.000). When subdivided by corneal layer, significant changes in CD were detected in the anterior 120 μm layer (χ(2)=27.774, P< 0.000). The CD increased significantly (i.e., corneal transparency decreased) as compared to the preoperative baseline on the first postoperative day, and lasted through the first week. There were no significant changes in the CD of the central layer (χ(2)=0.918, P =0.986). Significant increases in the posterior 60 μm of the cornea after surgery were found only at the 6-month and 1-year follow-up examinations (χ(2)=17.469, P= 0.008). No correlation was found in the preoperative refractive error, ablation depth, postoperative UCVA and the CD. The CD at 6 months was found negatively correlated with SE at 6 months ( r= -0.219, P =0.028). Conclusions: SMILE reduced corneal transparency temporarily and primarily within the surgically altered area, however such change has no significant correlation with the ablation depth, SE, and the postoperative UCVA. Transparency recovered within a month, but patients should be monitored for at least 1 year. (Chin J Ophthalmol, 2018, 54: 27-32) .

  20. Studies of atmospheric refraction effects on laser data

    NASA Technical Reports Server (NTRS)

    Dunn, P. J.; Pearce, W. A.; Johnson, T. S.

    1982-01-01

    The refraction effect from three perspectives was considered. An analysis of the axioms on which the accepted correction algorithms were based was the first priority. The integrity of the meteorological measurements on which the correction model is based was also considered and a large quantity of laser observations was processed in an effort to detect any serious anomalies in them. The effect of refraction errors on geodetic parameters estimated from laser data using the most recent analysis procedures was the focus of the third element of study. The results concentrate on refraction errors which were found to be critical in the eventual use of the data for measurements of crustal dynamics.

  1. Effects of tropospheric and ionospheric refraction errors in the utilization of GEOS-C altimeter data

    NASA Technical Reports Server (NTRS)

    Goad, C. C.

    1977-01-01

    The effects of tropospheric and ionospheric refraction errors are analyzed for the GEOS-C altimeter project in terms of their resultant effects on C-band orbits and the altimeter measurement itself. Operational procedures using surface meteorological measurements at ground stations and monthly means for ocean surface conditions are assumed, with no corrections made for ionospheric effects. Effects on the orbit height due to tropospheric errors are approximately 15 cm for single pass short arcs (such as for calibration) and 10 cm for global orbits of one revolution. Orbit height errors due to neglect of the ionosphere have an amplitude of approximately 40 cm when the orbits are determined from C-band range data with predominantly daylight tracking. Altimeter measurement errors are approximately 10 cm due to residual tropospheric refraction correction errors. Ionospheric effects on the altimeter range measurement are also on the order of 10 cm during the GEOS-C launch and early operation period.

  2. Refractive aim and visual outcome after phacoemulsification: A 2-year review from a Tertiary Private Eye Hospital in Sub-Saharan Africa.

    PubMed

    Oderinlo, O; Hassan, A O; Oluyadi, F O; Ogunro, A O; Okonkwo, O N; Ulaikere, M O; Ashano, O

    2017-02-01

    To review the short-term visual outcome of phacoemulsification in adults with uncomplicated cataracts in Eye Foundation Hospital, Lagos, Nigeria. A retrospective review of records of patients that had phacoemulsification between January 2012 and December 2013 in Eye Foundation Hospital, Lagos, Nigeria, was done. Preoperative visual acuity, refractive aim, intraoperative complications, postoperative unaided, and best-corrected visual acuity at 1 and 3 months were analyzed. Only eyes of adults that had phacoemulsification for uncomplicated cataracts were included in the study, all pediatric cataracts and eyes with ocular comorbidities were excluded. Common ocular comorbidities excluded were corneal opacity/corneal scar, glaucoma, uveitis, pseudo exfoliation syndrome, moderate and severe nonproliferative diabetic retinopathy, macula edema, proliferative diabetic retinopathy, eye trauma, age-related macular degeneration, previous corneal surgery, glaucoma surgery, and previous or simultaneous vitreoretinal surgery. A total of 157 eyes of 119 patients who met the inclusion criteria were analyzed. There were 60 (50.4%) females and 59 (49.6%) males, with age range from 31 to 91 years and a mean of 65.3 ± 11.10 years. Only eyes with available data were analyzed at 1 and 3 months postoperatively. In 112 eyes (85.7%), the refractive aim was met, 21 eyes (14.3%) did not meet their refractive aim, 20 eyes (12.7%) were excluded, the refractive aim could not be determined from the records as surgeons did not specify, and in 4 eyes, the required information was missing from the case files. An unaided visual acuity of 6/18 and better was achieved in 134 eyes (85.4%) at 1 month and 126 eyes (85.9%) at 3 months whereas best-corrected vision of 6/18 and better was achieved by 145 eyes (92.4%) at 1 month and 146 eyes (98.0%) at 3 months. Surgical outcomes after phacoemulsification are comparable with international benchmarks for good outcomes, with 85.4% of eyes achieving within 1 D of spherical equivalent of the refractive aim, 92.4% and 98.0% of eyes also achieving best-corrected visual acuities of 6/18 and better at 1 and 3 postoperative months, respectively. Unaided vision of 6/18 and better was also achieved in 85.4% and 85.9% at 1 and 3 postoperative months, respectively.

  3. Refractive Status at Birth: Its Relation to Newborn Physical Parameters at Birth and Gestational Age

    PubMed Central

    Varghese, Raji Mathew; Sreenivas, Vishnubhatla; Puliyel, Jacob Mammen; Varughese, Sara

    2009-01-01

    Background Refractive status at birth is related to gestational age. Preterm babies have myopia which decreases as gestational age increases and term babies are known to be hypermetropic. This study looked at the correlation of refractive status with birth weight in term and preterm babies, and with physical indicators of intra-uterine growth such as the head circumference and length of the baby at birth. Methods All babies delivered at St. Stephens Hospital and admitted in the nursery were eligible for the study. Refraction was performed within the first week of life. 0.8% tropicamide with 0.5% phenylephrine was used to achieve cycloplegia and paralysis of accommodation. 599 newborn babies participated in the study. Data pertaining to the right eye is utilized for all the analyses except that for anisometropia where the two eyes were compared. Growth parameters were measured soon after birth. Simple linear regression analysis was performed to see the association of refractive status, (mean spherical equivalent (MSE), astigmatism and anisometropia) with each of the study variables, namely gestation, length, weight and head circumference. Subsequently, multiple linear regression was carried out to identify the independent predictors for each of the outcome parameters. Results Simple linear regression showed a significant relation between all 4 study variables and refractive error but in multiple regression only gestational age and weight were related to refractive error. The partial correlation of weight with MSE adjusted for gestation was 0.28 and that of gestation with MSE adjusted for weight was 0.10. Birth weight had a higher correlation to MSE than gestational age. Conclusion This is the first study to look at refractive error against all these growth parameters, in preterm and term babies at birth. It would appear from this study that birth weight rather than gestation should be used as criteria for screening for refractive error, especially in developing countries where the incidence of intrauterine malnutrition is higher. PMID:19214228

  4. Genome-wide association study for refractive astigmatism reveals genetic co-determination with spherical equivalent refractive error: the CREAM consortium.

    PubMed

    Li, Qing; Wojciechowski, Robert; Simpson, Claire L; Hysi, Pirro G; Verhoeven, Virginie J M; Ikram, Mohammad Kamran; Höhn, René; Vitart, Veronique; Hewitt, Alex W; Oexle, Konrad; Mäkelä, Kari-Matti; MacGregor, Stuart; Pirastu, Mario; Fan, Qiao; Cheng, Ching-Yu; St Pourcain, Beaté; McMahon, George; Kemp, John P; Northstone, Kate; Rahi, Jugnoo S; Cumberland, Phillippa M; Martin, Nicholas G; Sanfilippo, Paul G; Lu, Yi; Wang, Ya Xing; Hayward, Caroline; Polašek, Ozren; Campbell, Harry; Bencic, Goran; Wright, Alan F; Wedenoja, Juho; Zeller, Tanja; Schillert, Arne; Mirshahi, Alireza; Lackner, Karl; Yip, Shea Ping; Yap, Maurice K H; Ried, Janina S; Gieger, Christian; Murgia, Federico; Wilson, James F; Fleck, Brian; Yazar, Seyhan; Vingerling, Johannes R; Hofman, Albert; Uitterlinden, André; Rivadeneira, Fernando; Amin, Najaf; Karssen, Lennart; Oostra, Ben A; Zhou, Xin; Teo, Yik-Ying; Tai, E Shyong; Vithana, Eranga; Barathi, Veluchamy; Zheng, Yingfeng; Siantar, Rosalynn Grace; Neelam, Kumari; Shin, Youchan; Lam, Janice; Yonova-Doing, Ekaterina; Venturini, Cristina; Hosseini, S Mohsen; Wong, Hoi-Suen; Lehtimäki, Terho; Kähönen, Mika; Raitakari, Olli; Timpson, Nicholas J; Evans, David M; Khor, Chiea-Chuen; Aung, Tin; Young, Terri L; Mitchell, Paul; Klein, Barbara; van Duijn, Cornelia M; Meitinger, Thomas; Jonas, Jost B; Baird, Paul N; Mackey, David A; Wong, Tien Yin; Saw, Seang-Mei; Pärssinen, Olavi; Stambolian, Dwight; Hammond, Christopher J; Klaver, Caroline C W; Williams, Cathy; Paterson, Andrew D; Bailey-Wilson, Joan E; Guggenheim, Jeremy A

    2015-02-01

    To identify genetic variants associated with refractive astigmatism in the general population, meta-analyses of genome-wide association studies were performed for: White Europeans aged at least 25 years (20 cohorts, N = 31,968); Asian subjects aged at least 25 years (7 cohorts, N = 9,295); White Europeans aged <25 years (4 cohorts, N = 5,640); and all independent individuals from the above three samples combined with a sample of Chinese subjects aged <25 years (N = 45,931). Participants were classified as cases with refractive astigmatism if the average cylinder power in their two eyes was at least 1.00 diopter and as controls otherwise. Genome-wide association analysis was carried out for each cohort separately using logistic regression. Meta-analysis was conducted using a fixed effects model. In the older European group the most strongly associated marker was downstream of the neurexin-1 (NRXN1) gene (rs1401327, P = 3.92E-8). No other region reached genome-wide significance, and association signals were lower for the younger European group and Asian group. In the meta-analysis of all cohorts, no marker reached genome-wide significance: The most strongly associated regions were, NRXN1 (rs1401327, P = 2.93E-07), TOX (rs7823467, P = 3.47E-07) and LINC00340 (rs12212674, P = 1.49E-06). For 34 markers identified in prior GWAS for spherical equivalent refractive error, the beta coefficients for genotype versus spherical equivalent, and genotype versus refractive astigmatism, were highly correlated (r = -0.59, P = 2.10E-04). This work revealed no consistent or strong genetic signals for refractive astigmatism; however, the TOX gene region previously identified in GWAS for spherical equivalent refractive error was the second most strongly associated region. Analysis of additional markers provided evidence supporting widespread genetic co-susceptibility for spherical and astigmatic refractive errors.

  5. Effects of myopic spectacle correction and radial refractive gradient spectacles on peripheral refraction.

    PubMed

    Tabernero, Juan; Vazquez, Daniel; Seidemann, Anne; Uttenweiler, Dietmar; Schaeffel, Frank

    2009-08-01

    The recent observation that central refractive development might be controlled by the refractive errors in the periphery, also in primates, revived the interest in the peripheral optics of the eye. We optimized an eccentric photorefractor to measure the peripheral refractive error in the vertical pupil meridian over the horizontal visual field (from -45 degrees to 45 degrees ), with and without myopic spectacle correction. Furthermore, a newly designed radial refractive gradient lens (RRG lens) that induces increasing myopia in all radial directions from the center was tested. We found that for the geometry of our measurement setup conventional spectacles induced significant relative hyperopia in the periphery, although its magnitude varied greatly among different spectacle designs and subjects. In contrast, the newly designed RRG lens induced relative peripheral myopia. These results are of interest to analyze the effect that different optical corrections might have on the emmetropization process.

  6. Determination of effective complex refractive index of a turbid liquid with surface plasmon resonance phase detection.

    PubMed

    Yingying, Zhang; Jiancheng, Lai; Cheng, Yin; Zhenhua, Li

    2009-03-01

    The dependence of the surface plasmon resonance (SPR) phase difference curve on the complex refractive index of a sample in Kretschmann configuration is discussed comprehensively, based on which a new method is proposed to measure the complex refractive index of turbid liquid. A corresponding experiment setup was constructed to measure the SPR phase difference curve, and the complex refractive index of turbid liquid was determined. By using the setup, the complex refractive indices of Intralipid solutions with concentrations of 5%, 10%, 15%, and 20% are obtained to be 1.3377+0.0005 i, 1.3427+0.0028 i, 1.3476+0.0034 i, and 1.3496+0.0038 i, respectively. Furthermore, the error analysis indicates that the root-mean-square errors of both the real and the imaginary parts of the measured complex refractive index are less than 5x10(-5).

  7. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    PubMed

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  8. Corrective lens use and refractive error among United States Air Force aircrew.

    PubMed

    Wright, Steve T; Ivan, Douglas J; Clark, Patrick J; Gooch, John M; Thompson, William

    2010-03-01

    Corrective lens use by military aviators is an important consideration in the design of head-mounted equipment. The United States Air Force (USAF) has periodically monitored lens use by aviators; however, it has been over a decade since the last study. We provide an update on the prevalence of corrective lenses and refractive error among USAF aircrew based on eyeglass orders processed through the Spectacle Request Transmission System (SRTS). Currently, 41% of active duty USAF pilots and 54% of other aircrew require corrective lenses to perform flight duties. Refractive errors are characterized by low to moderate levels of myopia with a mean spherical equivalent power of -1.01 diopters (D) for pilots and -1.68 D for others. Contact lenses, and more recently refractive surgery, reduce the number of aircrew that must rely on spectacles when flying; however, spectacle compatibility remains an important consideration in the cockpit.

  9. Refractive errors and strabismus in Down's syndrome in Korea.

    PubMed

    Han, Dae Heon; Kim, Kyun Hyung; Paik, Hae Jung

    2012-12-01

    The aims of this study were to examine the distribution of refractive errors and clinical characteristics of strabismus in Korean patients with Down's syndrome. A total of 41 Korean patients with Down's syndrome were screened for strabismus and refractive errors in 2009. A total of 41 patients with an average age of 11.9 years (range, 2 to 36 years) were screened. Eighteen patients (43.9%) had strabismus. Ten (23.4%) of 18 patients exhibited esotropia and the others had intermittent exotropia. The most frequently detected type of esotropia was acquired non-accommodative esotropia, and that of exotropia was the basic type. Fifteen patients (36.6%) had hypermetropia and 20 (48.8%) had myopia. The patients with esotropia had refractive errors of +4.89 diopters (D, ±3.73) and the patients with exotropia had refractive errors of -0.31 D (±1.78). Six of ten patients with esotropia had an accommodation weakness. Twenty one patients (63.4%) had astigmatism. Eleven (28.6%) of 21 patients had anisometropia and six (14.6%) of those had clinically significant anisometropia. In Korean patients with Down's syndrome, esotropia was more common than exotropia and hypermetropia more common than myopia. Especially, Down's syndrome patients with esotropia generally exhibit clinically significant hyperopic errors (>+3.00 D) and evidence of under-accommodation. Thus, hypermetropia and accommodation weakness could be possible factors in esotropia when it occurs in Down's syndrome patients. Based on the results of this study, eye examinations of Down's syndrome patients should routinely include a measure of accommodation at near distances, and bifocals should be considered for those with evidence of under-accommodation.

  10. Pattern of refractive errors among patients at a tertiary hospital in Kathmandu.

    PubMed

    Rizyal, A; Ghising, R; Shrestha, R K; Kansakar, I

    2011-09-01

    A hospital based cross sectional study was carried out to determine the pattern of refractive errors among patients attending the out patient department, Department of Ophthalmology, Nepal Medical College Teaching Hospital. A total of 1100 patients were evaluated, (male 43.67%; female 56.33%). Simple myopic astigmatism was the most prevalent type of refractive error accounting for 27.18% followed by simple myopia (21.66%) and compound myopic astigmatism (19.48%). Simple hypermetropia (15.03%) and mixed astigmatism (4.3%) were also noted. Simple myopia was prevalent among the younger age group in the first to third decades, whereas hypermetropia was seen in the older patients in the third to fifth decades.

  11. Adjuvant corneal crosslinking to prevent hyperopic LASIK regression

    PubMed Central

    Aslanides, Ioannis M; Mukherjee, Achyut N

    2013-01-01

    Purpose To report the long term outcomes, safety, stability, and efficacy in a pilot series of simultaneous hyperopic laser assisted in situ keratomileusis (LASIK) and corneal crosslinking (CXL). Method A small cohort series of five eyes, with clinically suboptimal topography and/or thickness, underwent LASIK surgery with immediate riboflavin application under the flap, followed by UV light irradiation. Postoperative assessment was performed at 1, 3, 6, and 12 months, with late follow up at 4 years, and results were compared with a matched cohort that received LASIK only. Results The average age of the LASIK-CXL group was 39 years (26–46), and the average spherical equivalent hyperopic refractive error was +3.45 diopters (standard deviation 0.76; range 2.5 to 4.5). All eyes maintained refractive stability over the 4 years. There were no complications related to CXL, and topographic and clinical outcomes were as expected for standard LASIK. Conclusion This limited series suggests that simultaneous LASIK and CXL for hyperopia is safe. Outcomes of the small cohort suggest that this technique may be promising for ameliorating hyperopic regression, presumed to be biomechanical in origin, and may also address ectasia risk. PMID:23576861

  12. [Value the correction of corneal astigmatism in cataract surgery].

    PubMed

    Wang, J; Cao, Y X

    2018-05-11

    The aim of modern micro-incision phacoemulsification combined with foldable intraocular lens implantation and femtosecond laser-assisted cataract surgery is evolving from a simple pursuit of recuperation to a refractive procedure, which involves the correction of ametropia according to preoperative and postoperative refractive conditions, especially corneal astigmatism, in order to achieve the goal of optimized postoperative uncorrected full range of vision. Nowadays, due attention to the effect of preoperative corneal astigmatism, surgery-induced astigmatism and residual astigmatism after operation is lacked, which affect postoperative visual acuity significantly. There are many effective ways to reduce corneal astigmatism after cataract surgery including selecting appropriate size and location of clear corneal incision, employing astigmatism keratotomy and the implantation of Toric intraocular lenses, which need to be appropriately applied and popularized. At the same time, surgical indications, predictability and safety should also be taken into account. (Chin J Ophthalmol, 2018, 54: 321-323) .

  13. Baseline peripheral refractive error and changes in axial refraction during one year in a young adult population.

    PubMed

    Hartwig, Andreas; Charman, William Neil; Radhakrishnan, Hema

    2016-01-01

    To determine whether the initial characteristics of individual patterns of peripheral refraction relate to subsequent changes in refraction over a one-year period. 54 myopic and emmetropic subjects (mean age: 24.9±5.1 years; median 24 years) with normal vision were recruited and underwent conventional non-cycloplegic subjective refraction. Peripheral refraction was also measured at 5° intervals over the central 60° of horizontal visual field, together with axial length. After one year, measurements of subjective refraction and axial length were repeated on the 43 subjects who were still available for examination. In agreement with earlier studies, higher myopes tended to show greater relative peripheral hyperopia. There was, however, considerable inter-subject variation in the pattern of relative peripheral refractive error (RPRE) at any level of axial refraction. Across the group, mean one-year changes in axial refraction and axial length did not differ significantly from zero. There was no correlation between changes in these parameters for individual subjects and any characteristic of their RPRE. No evidence was found to support the hypothesis that the pattern of RPRE is predictive of subsequent refractive change in this age group. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  14. Refractive errors, visual impairment, and the use of low-vision devices in albinism in Malawi.

    PubMed

    Schulze Schwering, M; Kumar, N; Bohrmann, D; Msukwa, G; Kalua, K; Kayange, P; Spitzer, M S

    2015-04-01

    This study focuses on the refractive implications of albinism in Malawi, which is mostly associated with the burden of visual impairment. The main goal was to describe the refractive errors and to analyze whether patients with albinism in Malawi, Sub-Saharan Africa, benefit from refraction. Age, sex, refractive data, uncorrected and best-corrected visual acuity (UCVA, BCVA), colour vision, contrast sensitivity, and the prescription of sunglasses and low vision devices were collected for a group of 120 albino individuals with oculocutaneous albinism (OCA). Refractive errors were evaluated objectively and subjectively by retinoscopy, and followed by cycloplegic refraction to reconfirm the results. Best-corrected visual acuity (BCVA) was also assessed binocularly. One hundred and twenty albino subjects were examined, ranging in age from 4 to 25 years (median 12 years), 71 (59 %) boys and 49 (41 %) girls. All exhibited horizontal pendular nystagmus. Mean visual acuity improved from 0.98 (0.33) logMAR to 0.77 (0.15) logMAR after refraction (p < 0.001). The best improvement of VA was achieved in patients with mild to moderate myopia. Patients with albinism who were hyperopic more than +1.5 D hardly improved from refraction. With the rule (WTR) astigmatism was more present (37.5 %) than against the rule (ATR) astigmatism (3.8 %). Patients with astigmatism less than 1.5 D improved in 15/32 of cases (47 %) by 2 lines or more. Patients with astigmatism equal to or more than 1.5 D in any axis improved in 26/54 of cases (48 %) by 2 lines or more. Refraction improves visual acuity of children with oculocutaneous albinism in a Sub-Saharan African population in Malawi. The mean improvement was 2 logMAR units.

  15. The prevalence rates of refractive errors among children, adolescents, and adults in Germany.

    PubMed

    Jobke, Sandra; Kasten, Erich; Vorwerk, Christian

    2008-09-01

    The prevalence rates of myopia vary between 5% in Australian Aborigines to 84% in Hong Kong and Taiwan, 30% in Norwegian adults, and 49.5% in Swedish schoolchildren. The aim of this study was to determine the prevalence of refractive errors in German children, adolescents, and adults. The parents (aged 24-65 years) and their children (516 subjects aged 2-35 years) were asked to fill out a questionnaire about their refractive error and spectacle use. Emmetropia was defined as refractive status between +0.25D and -0.25D. Myopia was characterized as /=+0.5D. All information concerning refractive error were controlled by asking their opticians. The prevalence rates of myopia differed significantly between all investigated age groups: it was 0% in children aged 2-6 years, 5.5% in children aged 7-11 years, 21.0% in adolescents (aged 12-17 years) and 41.3% in adults aged 18-35 years (Pearson's Chi-square, p = 0.000). Furthermore, 9.8% of children aged 2-6 years were hyperopic, 6.4% of children aged 7-11 years, 3.7% of adolescents, and 2.9% of adults (p = 0.380). The prevalence of myopia in females (23.6%) was significantly higher than in males (14.6%, p = 0.018). The difference between the self-reported and the refractive error reported by their opticians was very small and was not significant (p = 0.850). In Germany, the prevalence of myopia seems to be somewhat lower than in Asia and Europe. There are few comparable studies concerning the prevalence rates of hyperopia.

  16. The Effect of Age, Accommodation and Refractive Error on the Adult Human Eye

    PubMed Central

    Richdale, Kathryn; Bullimore, Mark A.; Sinnott, Loraine T.; Zadnik, Karla

    2015-01-01

    Purpose To quantify changes in ocular dimensions associated with age, refractive error, and accommodative response, in vivo, in 30- to 50-year-old human subjects. Methods The right eyes of 91 adults were examined using ultrasonography, phakometry, keratometry, pachymetry, interferometry, anterior segment optical coherence tomography, and high resolution magnetic resonance imaging. Accommodation was measured subjectively with a push-up test and objectively using open-field autorefraction. Regression analyses were used to assess differences in ocular parameters with age, refractive error and accommodation. Results With age, crystalline lens thickness increased (0.03 mm/yr), anterior lens curvature steepened (0.11 mm/yr), anterior chamber depth decreased (0.02 mm/y) and lens equivalent refractive index decreased (0.001 /y) (all p < 0.01). With increasing myopia, there were significant increases in axial length (0.37 mm/D), vitreous chamber depth (0.34 mm/D), vitreous chamber height (0.09 mm/D) and ciliary muscle ring diameter (0.10 mm/D) (all p < 0.05). Increasing myopia was also associated with steepening of both the cornea (0.16 mm/D) and anterior lens surface (0.011 mm/D) (both p < 0.04). With accommodation, the ciliary muscle ring diameter decreased (0.08 mm/D), and the muscle thinned posteriorly (0.008 mm/D), allowing the lens to shorten equatorially (0.07 mm/D) and thicken axially (0.06 mm/D) (all p < 0.03). Conclusions Refractive error is significantly correlated with not only the axial dimensions, but the anterior equatorial dimension of the adult eye. Further testing and development of accommodating intraocular lenses should account for differences in patients’ preoperative refractive error. PMID:26703933

  17. Prevalence and associated risk factors of undercorrected refractive errors among people with diabetes in Shanghai.

    PubMed

    Zhu, Mengjun; Tong, Xiaowei; Zhao, Rong; He, Xiangui; Zhao, Huijuan; Zhu, Jianfeng

    2017-11-28

    To investigate the prevalence and risk factors of undercorrected refractive error (URE) among people with diabetes in the Baoshan District of Shanghai, where data for undercorrected refractive error are limited. The study was a population-based survey of 649 persons (aged 60 years or older) with diabetes in Baoshan, Shanghai in 2009. One copy of the questionnaire was completed for each subject. Examinations included a standardized refraction and measurement of presenting and best-corrected visual acuity (BCVA), tonometry, slit lamp biomicroscopy, and fundus photography. The calculated age-standardized prevalence rate of URE was 16.63% (95% confidence interval [CI] 13.76-19.49). For visual impairment subjects (presenting vision worse than 20/40 in the better eye), the prevalence of URE was up to 61.11%, and 75.93% of subjects could achieve visual acuity improvement by at least one line using appropriate spectacles. Under multiple logistic regression analysis, older age, female gender, non-farmer, increasing degree of myopia, lens opacities status, diabetic retinopathy (DR), body mass index (BMI) index lower than normal, and poor glycaemic control were associated with higher URE levels. Wearing distance eyeglasses was a protective factor for URE. The undercorrected refractive error in diabetic adults was high in Shanghai. Health education and regular refractive assessment are needed for diabetic adults. Persons with diabetes should be more aware that poor vision is often correctable, especially for those with risk factors.

  18. Genome-wide meta-analyses of multiancestry cohorts identify multiple new susceptibility loci for refractive error and myopia.

    PubMed

    Verhoeven, Virginie J M; Hysi, Pirro G; Wojciechowski, Robert; Fan, Qiao; Guggenheim, Jeremy A; Höhn, René; MacGregor, Stuart; Hewitt, Alex W; Nag, Abhishek; Cheng, Ching-Yu; Yonova-Doing, Ekaterina; Zhou, Xin; Ikram, M Kamran; Buitendijk, Gabriëlle H S; McMahon, George; Kemp, John P; Pourcain, Beate St; Simpson, Claire L; Mäkelä, Kari-Matti; Lehtimäki, Terho; Kähönen, Mika; Paterson, Andrew D; Hosseini, S Mohsen; Wong, Hoi Suen; Xu, Liang; Jonas, Jost B; Pärssinen, Olavi; Wedenoja, Juho; Yip, Shea Ping; Ho, Daniel W H; Pang, Chi Pui; Chen, Li Jia; Burdon, Kathryn P; Craig, Jamie E; Klein, Barbara E K; Klein, Ronald; Haller, Toomas; Metspalu, Andres; Khor, Chiea-Chuen; Tai, E-Shyong; Aung, Tin; Vithana, Eranga; Tay, Wan-Ting; Barathi, Veluchamy A; Chen, Peng; Li, Ruoying; Liao, Jiemin; Zheng, Yingfeng; Ong, Rick T; Döring, Angela; Evans, David M; Timpson, Nicholas J; Verkerk, Annemieke J M H; Meitinger, Thomas; Raitakari, Olli; Hawthorne, Felicia; Spector, Tim D; Karssen, Lennart C; Pirastu, Mario; Murgia, Federico; Ang, Wei; Mishra, Aniket; Montgomery, Grant W; Pennell, Craig E; Cumberland, Phillippa M; Cotlarciuc, Ioana; Mitchell, Paul; Wang, Jie Jin; Schache, Maria; Janmahasatian, Sarayut; Janmahasathian, Sarayut; Igo, Robert P; Lass, Jonathan H; Chew, Emily; Iyengar, Sudha K; Gorgels, Theo G M F; Rudan, Igor; Hayward, Caroline; Wright, Alan F; Polasek, Ozren; Vatavuk, Zoran; Wilson, James F; Fleck, Brian; Zeller, Tanja; Mirshahi, Alireza; Müller, Christian; Uitterlinden, André G; Rivadeneira, Fernando; Vingerling, Johannes R; Hofman, Albert; Oostra, Ben A; Amin, Najaf; Bergen, Arthur A B; Teo, Yik-Ying; Rahi, Jugnoo S; Vitart, Veronique; Williams, Cathy; Baird, Paul N; Wong, Tien-Yin; Oexle, Konrad; Pfeiffer, Norbert; Mackey, David A; Young, Terri L; van Duijn, Cornelia M; Saw, Seang-Mei; Bailey-Wilson, Joan E; Stambolian, Dwight; Klaver, Caroline C; Hammond, Christopher J

    2013-03-01

    Refractive error is the most common eye disorder worldwide and is a prominent cause of blindness. Myopia affects over 30% of Western populations and up to 80% of Asians. The CREAM consortium conducted genome-wide meta-analyses, including 37,382 individuals from 27 studies of European ancestry and 8,376 from 5 Asian cohorts. We identified 16 new loci for refractive error in individuals of European ancestry, of which 8 were shared with Asians. Combined analysis identified 8 additional associated loci. The new loci include candidate genes with functions in neurotransmission (GRIA4), ion transport (KCNQ5), retinoic acid metabolism (RDH5), extracellular matrix remodeling (LAMA2 and BMP2) and eye development (SIX6 and PRSS56). We also confirmed previously reported associations with GJD2 and RASGRF1. Risk score analysis using associated SNPs showed a tenfold increased risk of myopia for individuals carrying the highest genetic load. Our results, based on a large meta-analysis across independent multiancestry studies, considerably advance understanding of the mechanisms involved in refractive error and myopia.

  19. Influence of uncorrected refractive error and unmet refractive error on visual impairment in a Brazilian population.

    PubMed

    Ferraz, Fabio H; Corrente, José E; Opromolla, Paula; Schellini, Silvana A

    2014-06-25

    The World Health Organization (WHO) definitions of blindness and visual impairment are widely based on best-corrected visual acuity excluding uncorrected refractive errors (URE) as a visual impairment cause. Recently, URE was included as a cause of visual impairment, thus emphasizing the burden of visual impairment due to refractive error (RE) worldwide is substantially higher. The purpose of the present study is to determine the reversal of visual impairment and blindness in the population correcting RE and possible associations between RE and individual characteristics. A cross-sectional study was conducted in nine counties of the western region of state of São Paulo, using systematic and random sampling of households between March 2004 and July 2005. Individuals aged more than 1 year old were included and were evaluated for demographic data, eye complaints, history, and eye exam, including no corrected visual acuity (NCVA), best corrected vision acuity (BCVA), automatic and manual refractive examination. The definition adopted for URE was applied to individuals with NCVA > 0.15 logMAR and BCVA ≤ 0.15 logMAR after refractive correction and unmet refractive error (UREN), individuals who had visual impairment or blindness (NCVA > 0.5 logMAR) and BCVA ≤ 0.5 logMAR after optical correction. A total of 70.2% of subjects had normal NCVA. URE was detected in 13.8%. Prevalence of 4.6% of optically reversible low vision and 1.8% of blindness reversible by optical correction were found. UREN was detected in 6.5% of individuals, more frequently observed in women over the age of 50 and in higher RE carriers. Visual impairment related to eye diseases is not reversible with spectacles. Using multivariate analysis, associations between URE and UREN with regard to sex, age and RE was observed. RE is an important cause of reversible blindness and low vision in the Brazilian population.

  20. Influence of uncorrected refractive error and unmet refractive error on visual impairment in a Brazilian population

    PubMed Central

    2014-01-01

    Background The World Health Organization (WHO) definitions of blindness and visual impairment are widely based on best-corrected visual acuity excluding uncorrected refractive errors (URE) as a visual impairment cause. Recently, URE was included as a cause of visual impairment, thus emphasizing the burden of visual impairment due to refractive error (RE) worldwide is substantially higher. The purpose of the present study is to determine the reversal of visual impairment and blindness in the population correcting RE and possible associations between RE and individual characteristics. Methods A cross-sectional study was conducted in nine counties of the western region of state of São Paulo, using systematic and random sampling of households between March 2004 and July 2005. Individuals aged more than 1 year old were included and were evaluated for demographic data, eye complaints, history, and eye exam, including no corrected visual acuity (NCVA), best corrected vision acuity (BCVA), automatic and manual refractive examination. The definition adopted for URE was applied to individuals with NCVA > 0.15 logMAR and BCVA ≤ 0.15 logMAR after refractive correction and unmet refractive error (UREN), individuals who had visual impairment or blindness (NCVA > 0.5 logMAR) and BCVA ≤ 0.5 logMAR after optical correction. Results A total of 70.2% of subjects had normal NCVA. URE was detected in 13.8%. Prevalence of 4.6% of optically reversible low vision and 1.8% of blindness reversible by optical correction were found. UREN was detected in 6.5% of individuals, more frequently observed in women over the age of 50 and in higher RE carriers. Visual impairment related to eye diseases is not reversible with spectacles. Using multivariate analysis, associations between URE and UREN with regard to sex, age and RE was observed. Conclusion RE is an important cause of reversible blindness and low vision in the Brazilian population. PMID:24965318

  1. Correlation between dry eye and refractive error in Saudi young adults using noninvasive Keratograph 4

    PubMed Central

    Fahmy, Rania M; Aldarwesh, Amal

    2018-01-01

    Purpose: The purpose is to study the correlation between dry eye and refractive errors in young adults using noninvasive Keratograph. Methods: In this cross sectional study, a total of 126 participants in the age range of 19–25 years and who were free of ocular surface disease, were recruited from King Saud University Campus. Refraction was defined by the spherical equivalent (SE) as the following: 49 emmetropic eyes (±0.50 SE), 48 myopic eyes (≤−0.75 SE and above), and 31 hyperopic eyes (>+0.75 SE). All participants underwent full ophthalmic examinations assessing their refractive status and dryness level including noninvasive breakup time (NIBUT) and tear meniscus height using Keratograph 4. Results: The prevalence of dry eye was 24.6%, 36.5%, and 17.4% in emmetropes, myopes, and hypermetropes, respectively. NIBUT has a negative correlation with hyperopia and a positive correlation with myopia with a significant reduction in the average NIBUT in myopes and hypermetropes in comparison to emmetropes. Conclusion: The current results succeeded to demonstrate a correlation between refractive errors and dryness level. PMID:29676308

  2. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at initial cataract extraction, compliance with amblyopia therapy, and refractive error. PMID:26230501

  3. Screening athletes with Down syndrome for ocular disease.

    PubMed

    Gutstein, Walter; Sinclair, Stephen H; North, Rachel V; Bekiroglu, N

    2010-02-01

    Persons with Down syndrome are well known to have a high prevalence of vision and eye health problems, many of which are undetected or untreated primarily because of infrequent ocular examinations. Public screening programs, directed toward the pediatric population, have become more popular and commonly use letter or symbol charts. This study compares 2 vision screening methods, the Lea Symbol chart and a newly developed interactive computer program, the Vimetrics Central Vision Analyzer (CVA), in their ability to identify ocular disease in the Down syndrome population. Athletes with Down syndrome participating in the European Special Olympics underwent an ocular screening including history, auto-refraction, colour vision assessment, stereopsis assessment, motility assessment, pupil reactivity, and tonometry testing, as well as anterior segment and fundus examinations to evaluate for ocular disease. Visual acuity was tested with the Lea chart and CVA to evaluate these as screening tests for detecting ocular disease as well as significant, uncorrected refractive errors. Among the 91 athletes that presented to the screening, 79 (158 eyes) were sufficiently cooperative for the examination to be completed. Mean age was 26 years +/-10.8 SD. Significant, uncorrected refractive errors (>/=1.00 spherical equivalent) were detected in 28 (18%) eyes and ocular pathology in 51 (32%) eyes. The Lea chart sensitivity and specificity were 43% and 74%, respectively, for detecting ocular pathology and 58% and 100% for detecting uncorrected refractive errors. The CVA sensitivity and specificity were 70% and 86% for detecting pathology and 71% and 100% for detecting uncorrected refractive errors. This study confirmed the findings of prior studies in identifying a significant presence of uncorrected refractive errors and ocular pathology in the Down syndrome population. Screening with the Lea symbol chart found borderline sufficient sensitivity and specificity for the test to be used for screening in this population. The better sensitivity and specificity of the CVA, if adjusted normative values are utilized, appear to make this test sufficient for testing Down syndrome children for identifying both refractive errors and ocular pathology. Copyright 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  4. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers.

    PubMed

    Gazieva, Lola; Beer, Mette Hjuler; Nielsen, Kim; Hjortdal, Jesper

    2011-12-01

    To compare the visual refractive outcome and complication of laser in situ keratomileusis (LASIK) carried out with a Carl Zeiss-Meditec MEL-70 Excimer laser and a MEL-80 laser for treatment of high myopia. Journal records of 680 consecutive eyes that underwent LASIK with a Schwind Supratome microkeratome and a MEL-70 Excimer laser (Group A), or a Moria M2 microkeratome and a MEL-80 Excimer laser (Group B) were reviewed. Manifest refraction, uncorrected and best spectacle-corrected visual acuity (BSCVA), corneal topography and central corneal thickness (CCT) were recorded before and 3 months after treatment. Pre- and postoperative complications, visual and refractive outcome and frequency of retreatments were registered. Mean preoperative spherical equivalent refraction was -8.52 dioptres (-5.50- -18 dioptres), and the mean attempted laser correction was -8.02 dioptres (-5.50- -11 dioptres). Three months after LASIK, the average treatment error (difference between achieved and attempted correction) was 1.20 (SD=1.19) dioptres of under correction in Group A and 0.52 (SD=1.00) dioptres in Group B. Four eyes lost more than two lines of BSCVA (0.6%). In 110 eyes (16%), a re-LASIK procedure was performed to reduce remaining myopia after the primary procedure. Laser in situ keratomileusis treatment for high myopia can effectively reduce high degrees of myopia. Under correction was observed in both treatment groups but Group B has a slightly better predictability. Significant loss of BSCVA occurs infrequently after LASIK for even considerable grades of myopia (0.6% in each group). © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  5. An alternative clinical routine for subjective refraction based on power vectors with trial frames.

    PubMed

    María Revert, Antonia; Conversa, Maria Amparo; Albarrán Diego, César; Micó, Vicente

    2017-01-01

    Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented at 0°/90° (J 0 component) and 45°/135° (J 45 component) for determination of astigmatism. This vector subjective refraction result (VR) is compared separately for right and left eyes of 25 subjects (mean age, 35 ± 4 years) against conventional sphero-cylindrical subjective refraction (RX) using a phoropter. The VR procedure was applied with both conventional tumbling E optotypes (VR1) and modified optotypes with oblique orientation (VR2). Bland-Altman plots and intra-class correlation coefficient showed good agreement between VR, and RX (with coefficient values above 0.82) and anova showed no significant differences in any of the power vector components between RX and VR. VR1 and VR2 procedure results were similar (p ≥ 0.77). The proposed routine determines the three components of refractive error in power vector notation [M, J 0 , J 45 ], with a refraction time similar to the one used in conventional subjective procedures. The proposed routine could be helpful for inexperienced clinicians and for experienced clinicians in those cases where it is difficult to get a valid starting point for conventional RX (irregular corneas, media opacities, etc.) and for refractive situations/places with inadequate refractive facilities/equipment. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  6. The prevalence of refractive errors among adults in the United States, Western Europe, and Australia.

    PubMed

    Kempen, John H; Mitchell, Paul; Lee, Kristine E; Tielsch, James M; Broman, Aimee T; Taylor, Hugh R; Ikram, M Kamran; Congdon, Nathan G; O'Colmain, Benita J

    2004-04-01

    To estimate the prevalence of refractive errors in persons 40 years and older. Counts of persons with phakic eyes with and without spherical equivalent refractive error in the worse eye of +3 diopters (D) or greater, -1 D or less, and -5 D or less were obtained from population-based eye surveys in strata of gender, race/ethnicity, and 5-year age intervals. Pooled age-, gender-, and race/ethnicity-specific rates for each refractive error were applied to the corresponding stratum-specific US, Western European, and Australian populations (years 2000 and projected 2020). Six studies provided data from 29 281 persons. In the US, Western European, and Australian year 2000 populations 40 years or older, the estimated crude prevalence for hyperopia of +3 D or greater was 9.9%, 11.6%, and 5.8%, respectively (11.8 million, 21.6 million, and 0.47 million persons). For myopia of -1 D or less, the estimated crude prevalence was 25.4%, 26.6%, and 16.4% (30.4 million, 49.6 million, and 1.3 million persons), respectively, of whom 4.5%, 4.6%, and 2.8% (5.3 million, 8.5 million, and 0.23 million persons), respectively, had myopia of -5 D or less. Projected prevalence rates in 2020 were similar. Refractive errors affect approximately one third of persons 40 years or older in the United States and Western Europe, and one fifth of Australians in this age group.

  7. Vision-Enhancing Interventions in Nursing Home Residents and Their Short-Term Impact on Physical and Cognitive Function

    PubMed Central

    Elliott, Amanda F.; McGwin, Gerald; Owsley, Cynthia

    2009-01-01

    OBJECTIVE To evaluate the effect of vision-enhancing interventions (i.e., cataract surgery or refractive error correction) on physical function and cognitive status in nursing home residents. DESIGN Longitudinal cohort study. SETTING Seventeen nursing homes in Birmingham, AL. PARTICIPANTS A total of 187 English-speaking older adults (>55 years of age). INTERVENTION Participants took part in one of two vision-enhancing interventions: cataract surgery or refractive error correction. Each group was compared against a control group (persons eligible for but who declined cataract surgery, or who received delayed correction of refractive error). MEASUREMENTS Physical function (i.e., ability to perform activities of daily living and mobility) was assessed with a series of self-report and certified nursing assistant ratings at baseline and at 2 months for the refractive error correction group, and at 4 months for the cataract surgery group. The Mini Mental State Exam was also administered. RESULTS No significant differences existed within or between groups from baseline to follow-up on any of the measures of physical function. Mental status scores significantly declined from baseline to follow-up for both the immediate (p= 0.05) and delayed (p< 0.02) refractive error correction groups and for the cataract surgery control group (p= 0.05). CONCLUSION Vision-enhancing interventions did not lead to short-term improvements in physical functioning or cognitive status in this sample of elderly nursing home residents. PMID:19170783

  8. Ciliary Body Thickness and Refractive Error in Children

    PubMed Central

    Bailey, Melissa D.; Sinnott, Loraine T.; Mutti, Donald O.

    2010-01-01

    Purpose To determine whether ciliary body thickness (CBT) is related to refractive error in school-age children. Methods Fifty-three children, 8 to 15 years of age, were recruited. CBT was measured from anterior segment OCT images (Visante; Carl Zeiss Meditec, Inc., Dublin, CA) at 1 (CBT1), 2 (CBT2) and 3 (CBT3) mm posterior to the scleral spur. Cycloplegic refractive error was measured with an autorefractor, and axial length was measured with an optical biometer. Multilevel regression models determined the relationship between CBT measurements and refractive error or axial length. A Bland-Altman analysis was used to assess the between-visit repeatability of the ciliary body measurements. Results The between-visits coefficients of repeatability for CBT1, -2, and -3 were 148.04, 165.68, and 110.90, respectively. Thicker measurements at CBT2 (r = −0.29, P = 0.03) and CBT3 (r = −0.38, P = 0.005) were associated with increasingly myopic refractive errors (multilevel model: P < 0.001). Thicker measurements at CBT2 (r = 0.40, P = 0.003) and CBT3 (r = 0.51, P < 0.001) were associated with longer axial lengths (multilevel model: P < 0.001). Conclusions Thicker ciliary body measurements were associated with myopia and a longer axial length. Future studies should determine whether this relationship is also present in animal models of myopia and determine the temporal relationship between thickening of the ciliary muscle and the onset of myopia. PMID:18566470

  9. MONOCULAR DIPLOPIA DUE TO SPHEROCYLINDRICAL REFRACTIVE ERRORS (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    Archer, Steven M.

    2007-01-01

    Purpose Ordinary spherocylindrical refractive errors have been recognized as a cause of monocular diplopia for over a century, yet explanation of this phenomenon using geometrical optics has remained problematic. This study tests the hypothesis that the diffraction theory treatment of refractive errors will provide a more satisfactory explanation of monocular diplopia. Methods Diffraction theory calculations were carried out for modulation transfer functions, point spread functions, and line spread functions under conditions of defocus, astigmatism, and mixed spherocylindrical refractive errors. Defocused photographs of inked and projected black lines were made to demonstrate the predicted consequences of the theoretical calculations. Results For certain amounts of defocus, line spread functions resulting from spherical defocus are predicted to have a bimodal intensity distribution that could provide the basis for diplopia with line targets. Multimodal intensity distributions are predicted in point spread functions and provide a basis for diplopia or polyopia of point targets under conditions of astigmatism. The predicted doubling effect is evident in defocused photographs of black lines, but the effect is not as robust as the subjective experience of monocular diplopia. Conclusions Monocular diplopia due to ordinary refractive errors can be predicted from diffraction theory. Higher-order aberrations—such as spherical aberration—are not necessary but may, under some circumstances, enhance the features of monocular diplopia. The physical basis for monocular diplopia is relatively subtle, and enhancement by neural processing is probably needed to account for the robustness of the percept. PMID:18427616

  10. Accuracy of noncycloplegic refraction performed at school screening camps.

    PubMed

    Khurana, Rolli; Tibrewal, Shailja; Ganesh, Suma; Tarkar, Rajoo; Nguyen, Phuong Thi Thanh; Siddiqui, Zeeshan; Dasgupta, Shantanu

    2018-06-01

    The aim of this study was to compare noncycloplegic refraction performed in school camp with that performed in eye clinic in children aged 6-16 years. A prospective study of children with unaided vision <0.2 LogMAR who underwent noncycloplegic retinoscopy (NCR) and subjective refraction (SR) in camp and subsequently in eye clinic between February and March 2017 was performed. A masked optometrist performed refractions in both settings. The agreement between refraction values obtained at both settings was compared using the Bland-Altman analysis. A total of 217 eyes were included in this study. Between the school camp and eye clinic, the mean absolute error ± standard deviation in spherical equivalent (SE) of NCR was 0.33 ± 0.4D and that of SR was 0.26 ± 0.5D. The limits of agreement for NCR were +0.91D to - 1.09D and for SR was +1.15D to -1.06D. The mean absolute error in SE was ≤0.5D in 92.62% eyes (95% confidence interval 88%-95%). A certain degree of variability exists between noncycloplegic refraction done in school camps and eye clinic. It was found to be accurate within 0.5D of SE in 92.62% eyes for refractive errors up to 4.5D of myopia, 3D of cylinder, and 1.5D of hyperopia.

  11. Refractive and Biometric Outcomes in Patients with Retinopathy of Prematurity Treated with Intravitreal Injection of Ranibizumab as Compared with Bevacizumab: A Clinical Study of Correction at Three Years of Age.

    PubMed

    Chen, Yen-Chih; Chen, San-Ni; Yang, Benjamin Chi-Lan; Lee, Kun-Hsien; Chuang, Chih-Chun; Cheng, Chieh-Yin

    2018-01-01

    To compare refractive and biometric outcomes in patients with type 1 retinopathy of prematurity (ROP) treated with intravitreal injection of ranibizumab (IVR) versus bevacizumab (IVB), at a corrected age of 3 years. A retrospective case series compared cycloplegic refractive statuses and biometric statuses in patients who received either IVR or IVB for type 1 ROP, from April 2011 to April 2014. A total of 62 eyes (33 patients) with type 1 ROP were evaluated (26 eyes in 13 IVR patients and 36 eyes in 20 IVB patients). There were no differences in birth statuses including gestational age and birth body weight between the two groups. The prevalence of refractive error greater than 1 D was higher in the IVB group ( p = 0.03), and there was a higher prevalence of high myopia (<-5.0 D, p = 0.03) in the IVB group. Comparisons in biometric finding showed that IVB patients had shallower anterior chamber depth ( p = 0.01). Both IVR and IVB showed low refractive errors, even followed at the corrected age of 3 years. No difference was noted between the two groups in refractive statuses. However, IVB was associated with shallower anterior chamber and higher prevalence of refractive error at the corrected age of 3 years. This trial is registered with NCT03334513.

  12. Refractive errors in students from Middle Eastern backgrounds living and undertaking schooling in Australia.

    PubMed

    Azizoglu, Serap; Junghans, Barbara M; Barutchu, Ayla; Crewther, Sheila G

    2011-01-01

      Environmental factors associated with schooling systems in various countries have been implicated in the rising prevalence of myopia, making the comparison of prevalence of refractive errors in migrant populations of interest. This study aims to determine the prevalence of refractive errors in children of Middle Eastern descent, raised and living in urban Australia but actively maintaining strong ties to their ethnic culture, and to compare them with those in the Middle East where myopia prevalence is generally low.   A total of 354 out of a possible 384 late primary/early secondary schoolchildren attending a private school attracting children of Middle Eastern background in Melbourne were assessed for refractive error and visual acuity. A Shin Nippon open-field NVision-K5001 autorefractor was used to carry out non-cycloplegic autorefraction while viewing a distant target. For statistical analyses students were divided into three age groups: 10-11 years (n = 93); 12-13 years (n = 158); and 14-15 years (n = 102).   All children were bilingual and classified as of Middle Eastern (96.3 per cent) or Egyptian (3.7 per cent) origin. Ages ranged from 10 to 15 years, with a mean of 13.17 ± 0.8 (SEM) years. Mean spherical equivalent refraction (SER) for the right eye was +0.09 ± 0.07 D (SEM) with a range from -7.77 D to +5.85 D. The prevalence of myopia, defined as a spherical equivalent refraction 0.50 D or more of myopia, was 14.7 per cent. The prevalence of hyperopia, defined as a spherical equivalent refraction of +0.75 D or greater, was 16.4 per cent, while hyperopia of +1.50 D or greater was 5.4 per cent. A significant difference in SER was seen as a function of age; however, no significant gender difference was seen.   This is the first study to report the prevalence of refractive errors for second-generation Australian schoolchildren coming from a predominantly Lebanese Middle Eastern Arabic background, who endeavour to maintain their ethnic ties. The relatively low prevalence of myopia is similar to that found for other metropolitan Australian school children but higher than that reported in the Middle East. These results suggest that lifestyle and educational practices may be a significant influence in the progression of myopic refractive errors. © 2010 The Authors. Clinical and Experimental Optometry © 2010 Optometrists Association Australia.

  13. Toric Intraocular Lens Outcomes in Patients With Glaucoma.

    PubMed

    Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G

    2015-06-01

    To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.

  14. Refractive Error in a Sample of Black High School Children in South Africa.

    PubMed

    Wajuihian, Samuel Otabor; Hansraj, Rekha

    2017-12-01

    This study focused on a cohort that has not been studied and who currently have limited access to eye care services. The findings, while improving the understanding of the distribution of refractive errors, also enabled identification of children requiring intervention and provided a guide for future resource allocation. The aim of conducting the study was to determine the prevalence and distribution of refractive error and its association with gender, age, and school grade level. Using a multistage random cluster sampling, 1586 children, 632 males (40%) and 954 females (60%), were selected. Their ages ranged between 13 and 18 years with a mean of 15.81 ± 1.56 years. The visual functions evaluated included visual acuity using the logarithm of minimum angle of resolution chart and refractive error measured using the autorefractor and then refined subjectively. Axis astigmatism was presented in the vector method where positive values of J0 indicated with-the-rule astigmatism, negative values indicated against-the-rule astigmatism, whereas J45 represented oblique astigmatism. Overall, patients were myopic with a mean spherical power for right eye of -0.02 ± 0.47; mean astigmatic cylinder power was -0.09 ± 0.27 with mainly with-the-rule astigmatism (J0 = 0.01 ± 0.11). The prevalence estimates were as follows: myopia (at least -0.50) 7% (95% confidence interval [CI], 6 to 9%), hyperopia (at least 0.5) 5% (95% CI, 4 to 6%), astigmatism (at least -0.75 cylinder) 3% (95% CI, 2 to 4%), and anisometropia 3% (95% CI, 2 to 4%). There was no significant association between refractive error and any of the categories (gender, age, and grade levels). The prevalence of refractive error in the sample of high school children was relatively low. Myopia was the most prevalent, and findings on its association with age suggest that the prevalence of myopia may be stabilizing at late teenage years.

  15. Knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city, Northwest Ethiopia.

    PubMed

    Alemayehu, Abiy Maru; Belete, Gizchewu Tilahun; Adimassu, Nebiyat Feleke

    2018-01-01

    Refractive error is an important cause of correctable visual impairment in the worldwide with a global distribution of 1.75% to 20.7% among schoolchildren. Teacher's knowledge about refractive error play an important role in encouraging students to seek treatment that helps in reducing the burden of visual impairment. To determine knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city. Institution based cross-sectional study was conducted on 565 primary school teachers in Gondar city using pretested and structured self-administered questionnaire. For processing and analysis, SPSS version 20 was used and variables which had a P value of <0.05 in the multivariable analysis were considered as statistically significant. A total of 565 study subjects were participated in this study with a mean age of 42.05 ± 12.01 years. Of these study participants 55.9% (95% CI: 51.9, 59.8) had good knowledge and 57.2% (95% CI: 52.9, 61.4) had favorable attitude towards refractive error. History of spectacle use [AOR = 2.13 (95% CI: 1.32, 3.43)], history of eye examination [AOR = 1.67 (95% CI: 1.19, 2.34)], training on eye health [AOR = 1.94 (95% CI; 1.09, 3.43)] and 11-20 years of experience [AOR = 2.53 (95% CI: 1.18, 5.43)] were positively associated with knowledge. Whereas being male [AOR = 2.03 (95% CI: 1.37, 3.01)], older age [AOR = 3.05 (95% CI: 1.07, 8.72)], 31-40 years of experience [AOR = 0.23 (95% CI: 0.07, 0.72)], private school type [AOR = 1.76 (95% CI: 1.06, 2.93)] and 5th -8th teaching category [AOR = 1.54 (95% CI: 1.05, 2.24)] were associated with attitude. Knowledge and attitude of study subjects were low which needs training of teachers about the refractive error.

  16. Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser system.

    PubMed

    Tsiklis, Nikolaos S; Kymionis, George D; Pallikaris, Aristofanis I; Diakonis, Vasilios F; Ginis, Harilaos S; Kounis, George A; Panagopoulou, Sophia I; Pallikaris, Ioannis G

    2007-11-01

    To evaluate whether photorefractive keratectomy (PRK) for moderate myopia using a solid-state laser with a wavelength of 213 nm alters the corneal endothelial cell density. University refractive surgery center. The corneal endothelium was analyzed preoperatively and 1, 6, and 12 months postoperatively using corneal confocal microscopy (modified HRT II with a Rostock Cornea Module, Heidelberg Engineering) in 60 eyes (30 patients). Patients were randomized to have myopic PRK using a 213 nm wavelength solid-state laser (study group) or a conventional 193 nm wavelength excimer laser (control group). Three endothelial images were acquired in each of 30 preoperative normal eyes to evaluate the repeatability of endothelial cell density measurements. Repeated-measures analysis of variance was used to compare the variations in endothelial cell density between the 2 lasers and the changes in endothelial cell density over time. There were no statistically significant differences in sex, age, corneal pachymetry, attempted correction, preoperative endothelial cell density, or postoperative refractive outcomes (uncorrected visual acuity, best spectacle-corrected visual acuity, and spherical equivalent refraction) between the 2 groups (P>.05). The coefficient of repeatability of endothelial cell density was 131 cells/mm(2). The measured endothelial cell count per 1.0 mm(2) did not significantly change up to 1 year postoperatively in either group (both P>.05). No statistically significant difference was found between the 2 groups in any postoperative interval (P>.05). Photorefractive keratectomy for moderate myopia using a 213 nm wavelength solid-state laser or a conventional 193 nm wavelength excimer laser did not significantly affect corneal endothelial density during the 1-year postoperative period.

  17. Spectacle wearing in children randomised to ready-made or custom spectacles, and potential cost savings to programmes: study protocol for a randomised controlled trial.

    PubMed

    Morjaria, Priya; Murali, Kaushik; Evans, Jennifer; Gilbert, Clare

    2016-01-19

    Uncorrected refractive errors are the commonest cause of visual impairment in children, with myopia being the most frequent type. Myopia usually starts around 9 years of age and progresses throughout adolescence. Hyperopia usually affects younger children, and astigmatism affects all age groups. Many children have a combination of myopia and astigmatism. To correct refractive errors, the type and degree of refractive error are measured and appropriate corrective lenses prescribed and dispensed in the spectacle frame of choice. Custom spectacles (that is, with the correction specifically required for that individual) are required if astigmatism is present, and/or the refractive error differs between eyes. Spectacles without astigmatic correction and where the refractive error is the same in both eyes are straightforward to dispense. These are known as 'ready-made' spectacles. High-quality spectacles of this type can be produced in high volume at an extremely low cost. Although spectacle correction improves visual function, a high proportion of children do not wear their spectacles for a variety of reasons. The aim of this study is to compare spectacle wear at 3-4 months amongst school children aged 11 to 15 years who have significant, simple uncorrected refractive error randomised to ready-made or custom spectacles of equivalent quality, and to evaluate cost savings to programmes. The study will take place in urban and semi-urban government schools in Bangalore, India. The hypothesis is that similar proportions of children randomised to ready-made or custom spectacles will be wearing their spectacles at 3-4 months. The trial is a randomised, non-inferiority, double masked clinical trial of children with simple uncorrected refractive errors. After screening, children will be randomised to ready-made or custom spectacles. Children will choose their preferred frame design. After 3-4 months the children will be followed up to assess spectacle wear. Ready-made spectacles have benefits for providers as well as parents and children, as a wide range of prescriptions and frame types can be taken to schools and dispensed immediately. In contrast, custom spectacles have to be individually made up in optical laboratories, and taken back to the school and given to the correct child. ISRCTN14715120 (Controlled-Trials.com) Date registered: 04 February 2015.

  18. Visual impairment and spectacle use in schoolchildren in rural and urban regions in Beijing.

    PubMed

    Guo, Yin; Liu, Li Juan; Xu, Liang; Lv, Yan Yun; Tang, Ping; Feng, Yi; Meng, Lei; Jonas, Jost B

    2014-01-01

    To determine prevalence and associations of visual impairment and frequency of spectacle use among grade 1 and grade 4 students in Beijing. This school-based, cross-sectional study included 382 grade 1 children (age 6.3 ± 0.5 years) and 299 grade 4 children (age 9.4 ± 0.7 years) who underwent a comprehensive eye examination including visual acuity, noncycloplegic refractometry, and ocular biometry. Presenting visual acuity (mean 0.04 ± 0.17 logMAR) was associated with younger age (p = 0.002), hyperopic refractive error (p<0.001), and male sex (p = 0.03). Presenting visual impairment (presenting visual acuity ≤20/40 in the better eye) was found in 44 children (prevalence 6.64 ± 1.0% [95% confidence interval (CI) 4.74, 8.54]). Mean best-corrected visual acuity (right eyes -0.02 ± 0.04 logMAR) was associated with more hyperopic refractive error (p = 0.03) and rural region of habitation (p<0.001). The prevalence of best-corrected visual impairment (best-corrected visual acuity ≤20/40 in the better eye) was 2/652 (0.30 ± 0.21% [95% CI 0.00, 0.72]). Undercorrection of refractive error was present in 53 children (7.99 ± 1.05%) and was associated with older age (p = 0.003; B 0.53; OR 1.71 [95% CI 1.20, 2.42]), myopic refractive error (p = 0.001; B -0.72; OR 0.49 [95% CI 0.35, 0.68]), and longer axial length (p = 0.002; B 0.74; OR 2.10 [95% CI 1.32, 3.32]). Spectacle use was reported for 54 children (8.14 ± 1.06%). Mean refractive error of the worse eyes of these children was -2.09 ± 2.88 D (range -7.38 to +7.25 D). Factors associated with presenting visual impairment were older age, myopic refractive error, and higher maternal education level. Despite a prevalence of myopia of 33% in young schoolchildren in Greater Beijing, prevalence of best-corrected visual impairment (0.30% ± 0.21%), presenting visual impairment (6.64% ± 1.0%), and undercorrection of refractive error (7.99% ± 1.05%) were relatively low.

  19. Screening for visual impairment: Outcome among schoolchildren in a rural area of Delhi

    PubMed Central

    Rustagi, Neeti; Uppal, Yogesh; Taneja, Devender K

    2012-01-01

    Background: Uncorrected refractive errors are the main cause of vision impairment in school-aged children. The current study focuses on the effectiveness of school eye screening in correcting refractive errors. Objectives: 1. To study the magnitude of visual impairment among school children. 2. To assess the compliance of students for refraction testing, procurement and use of spectacles. Materials and Methods: An intervention study was conducted in schools of the north- west district of Delhi, in the rural field practice area of a medical college. Students studying in five government schools in the field practice area were chosen as the study subjects. Results: Out of 1123 students enrolled, 1075 (95.7%) students were screened for refractive errors. Low vision (visual acuity < 20/60) in the better eye was observed in 31 (2.9%) children and blindness (visual acuity <20/200) in 10 (0.9%) children. Compliance with referral for refraction was very low as only 51 (41.5%) out of 123 students could be tested for refraction. Out of 48 students, 34 (70.8%) procured spectacles from family resources but its regular use was found among only 10 (29.4%) students. The poor compliance among students stems out of various myths and perceptions regarding use of spectacles prevalent in the community. Conclusion: Refractive error is an important cause of avoidable blindness among rural school children. Behavior change communication among rural masses by spreading awareness about eye health and conducting operational research at school and community level to involve parent's teachers associations and senior students to motivate students for use of spectacles may improve utilization of existing eye health services in rural areas. PMID:22569381

  20. Peripheral Vision Can Influence Eye Growth and Refractive Development in Infant Monkeys

    PubMed Central

    Smith, Earl L.; Kee, Chea-su; Ramamirtham, Ramkumar; Qiao-Grider, Ying; Hung, Li-Fang

    2006-01-01

    PURPOSE Given the prominence of central vision in humans, it has been assumed that visual signals from the fovea dominate emmetropization. The purpose of this study was to examine the impact of peripheral vision on emmetropization. METHODS Bilateral, peripheral form deprivation was produced in 12 infant monkeys by rearing them with diffusers that had either 4- or 8-mm apertures centered on the pupils of each eye, to allow 24° or 37° of unrestricted central vision, respectively. At the end of the lens-rearing period, an argon laser was used to ablate the fovea in one eye of each of seven monkeys. Subsequently, all the animals were allowed unrestricted vision. Refractive error and axial dimensions were measured along the pupillary axis by retinoscopy and A-scan ultrasonography, respectively. Control data were obtained from 21 normal monkeys and 3 infants reared with binocular plano lenses. RESULTS Nine of the 12 treated monkeys had refractive errors that fell outside the 10th- and 90th-percentile limits for the age-matched control subjects, and the average refractive error for the treated animals was more variable and significantly less hyperopic/more myopic (+0.03 ± 2.39 D vs. +2.39 ± 0.92 D). The refractive changes were symmetric in the two eyes of a given animal and axial in nature. After lens removal, all the treated monkeys recovered from the induced refractive errors. No interocular differences in the recovery process were observed in the animals with monocular foveal lesions. CONCLUSIONS On the one hand, the peripheral retina can contribute to emmetropizing responses and to ametropias produced by an abnormal visual experience. On the other hand, unrestricted central vision is not sufficient to ensure normal refractive development, and the fovea is not essential for emmetropizing responses. PMID:16249469

  1. Effects of Foveal Ablation on Emmetropization and Form-Deprivation Myopia

    PubMed Central

    Smith, Earl L.; Ramamirtham, Ramkumar; Qiao-Grider, Ying; Hung, Li-Fang; Huang, Juan; Kee, Chea-su; Coats, David; Paysse, Evelyn

    2009-01-01

    Purpose Because of the prominence of central vision in primates, it has generally been assumed that signals from the fovea dominate refractive development. To test this assumption, the authors determined whether an intact fovea was essential for either normal emmetropization or the vision-induced myopic errors produced by form deprivation. Methods In 13 rhesus monkeys at 3 weeks of age, the fovea and most of the perifovea in one eye were ablated by laser photocoagulation. Five of these animals were subsequently allowed unrestricted vision. For the other eight monkeys with foveal ablations, a diffuser lens was secured in front of the treated eyes to produce form deprivation. Refractive development was assessed along the pupillary axis by retinoscopy, keratometry, and A-scan ultrasonography. Control data were obtained from 21 normal monkeys and three infants reared with plano lenses in front of both eyes. Results Foveal ablations had no apparent effect on emmetropization. Refractive errors for both eyes of the treated infants allowed unrestricted vision were within the control range throughout the observation period, and there were no systematic interocular differences in refractive error or axial length. In addition, foveal ablation did not prevent form deprivation myopia; six of the eight infants that experienced monocular form deprivation developed myopic axial anisometropias outside the control range. Conclusions Visual signals from the fovea are not essential for normal refractive development or the vision-induced alterations in ocular growth produced by form deprivation. Conversely, the peripheral retina, in isolation, can regulate emmetropizing responses and produce anomalous refractive errors in response to abnormal visual experience. These results indicate that peripheral vision should be considered when assessing the effects of visual experience on refractive development. PMID:17724167

  2. Analysis of ionospheric refraction error corrections for GRARR systems

    NASA Technical Reports Server (NTRS)

    Mallinckrodt, A. J.; Parker, H. C.; Berbert, J. H.

    1971-01-01

    A determination is presented of the ionospheric refraction correction requirements for the Goddard range and range rate (GRARR) S-band, modified S-band, very high frequency (VHF), and modified VHF systems. The relation ships within these four systems are analyzed to show that the refraction corrections are the same for all four systems and to clarify the group and phase nature of these corrections. The analysis is simplified by recognizing that the range rate is equivalent to a carrier phase range change measurement. The equation for the range errors are given.

  3. Physiological pseudomyopia.

    PubMed

    Jones, R

    1990-08-01

    Objective refraction through plus fogging lenses and base-in prisms revealed that normally accommodation is not completely relaxed when the stimulus to accommodation is zero. The myopic shift in the refractive error due to this focus error of accommodation was defined as physiological pseudomyopia. Two previously established features of accommodation are responsible for this behavior: (1) accommodation acts as a proportional control system for steady-state responses; and (2) the rest focus of accommodation is nonzero. It is proposed that the hyperopic shift in refraction observed in cycloplegia is the result of elimination of physiological pseudomyopia.

  4. Preliminary results of VISX excimer laser myopic photorefractive keratectomy at Cedars-Sinai Medical Center

    NASA Astrophysics Data System (ADS)

    Maguen, Ezra I.; Berlin, Michael S.; Hofbauer, John; Macy, Jonathan I.; Nesburn, Anthony B.; Papaioannou, Thanassis; Salz, James J.

    1992-08-01

    Sixty-two eyes underwent excimer laser photorefractive keratectomy (PRK) for the correction of myopia at Cedars-Sinai-Medical-Center. The first group of 12 patients are presented with follow up data of ten months postoperatively. The second group of 50 patients are presented with follow up data of three months postoperatively. An in-depth comparison of pre and postoperative refractive data is presented. Comparisons between pre and postoperative corrected and uncorrected Snellen visual acuities are provided in order to asses the functional visual result of the procedure.

  5. Decreasing Uncorrected Refractive Error in the Classroom through a Multifactorial Pilot Intervention

    ERIC Educational Resources Information Center

    Kodjebacheva, Gergana; Maliski, Sally; Yu, Fei; Oelrich, Faye; Coleman, Anne L.

    2014-01-01

    The study assessed the effectiveness of a pilot intervention to promote the use of eyeglasses in one school in California. The intervention used a one-group pretest, posttest design. Between January and June 2011, during the intervention, all first- and second-grade children received eye evaluations and the children with refractive error received…

  6. Eye Accommodation, Personality, and Autonomic Balance.

    DTIC Science & Technology

    1979-11-01

    Wenger and Ellington, 1943, and by a technique introduced by Porges, 1976), refractive error (measured by dark focus, near and far points using a...focus, near and far points using a polarized vernier optometer), and introversion - extraversion (Eysenck Personality Inventory introversion...Porges, 1976), refractive error (measured by dark focus, near and far points using a polarized vernier optometer), and introversion - extraversion

  7. The effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia.

    PubMed

    Sefi-Yurdakul, Nazife; Kaykısız, Hüseyin; Koç, Feray

    2018-03-17

    To investigate the effects of partial and full correction of refractive errors on sensorial and motor outcomes in children with refractive accommodative esotropia (RAE). The records of pediatric cases with full RAE were reviewed; their first and last sensorial and motor findings were evaluated in two groups, classified as partial (Group 1) and full correction (Group 2) of refractive errors. The mean age at first admission was 5.84 ± 3.62 years in Group 1 (n = 35) and 6.35 ± 3.26 years in Group 2 (n = 46) (p = 0.335). Mean change in best corrected visual acuity (BCVA) was 0.24 ± 0.17 logarithm of the minimum angle of resolution (logMAR) in Group 1 and 0.13 ± 0.16 logMAR in Group 2 (p = 0.001). Duration of deviation, baseline refraction and amount of reduced refraction showed significant effects on change in BCVA (p < 0.05). Significant correlation was determined between binocular vision (BOV), duration of deviation and uncorrected baseline amount of deviation (p < 0.05). The baseline BOV rates were significantly high in fully corrected Group 2, and also were found to have increased in Group 1 (p < 0.05). Change in refraction was - 0.09 ± 1.08 and + 0.35 ± 0.76 diopters in Groups 1 and 2, respectively (p = 0.005). Duration of deviation, baseline refraction and the amount of reduced refraction had significant effects on change in refraction (p < 0.05). Change in deviation without refractive correction was - 0.74 ± 7.22 prism diopters in Group 1 and - 3.24 ± 10.41 prism diopters in Group 2 (p = 0.472). Duration of follow-up and uncorrected baseline deviation showed significant effects on change in deviation (p < 0.05). Although the BOV rates and BCVA were initially high in fully corrected patients, they finally improved significantly in both the fully and partially corrected patients. Full hypermetropic correction may also cause an increase in the refractive error with a possible negative effect on emmetropization. The negative effect of the duration of deviation on BOV and BCVA demonstrates the significance of early treatment in RAE cases.

  8. Comparison of postoperative intraocular pressure in patients with Densiron-68 vs conventional silicone oil: a case-control study.

    PubMed

    Wong, D; Kumar, I; Quah, S A; Ali, H; Valldeperas, X; Valdeperas, X; Romano, M R

    2009-01-01

    A solution of perfluorohexyloctane and silicone oil with a specific gravity of 1.06 g/cm(3) (Densiron-68) has similar properties as conventional silicone oil (SO) in terms of the shape of the bubble and its ability to act as an internal tamponade agent. We conducted a case-control study to compare the postoperative intraocular pressure (IOP) in patients treated with Densiron-68 with those treated with SO. Seventy-one eyes of 71 patients and 57 eyes of 57 patients who had received Densiron-68 and SO, respectively, were included in our study. Both groups were found to have matched for their preoperative comorbidities (diabetes, glaucoma, phakic status, and refractive errors). IOP at first day, between seventh and fourteenth day, and at 4 week postoperatively was recorded. The mean IOP was higher in patients treated with Densiron-68 at day 1 and between seventh and fourteenth day postoperatively (P=0.05 and 0.01, respectively). By the 4th week, the IOP difference between the two groups was insignificant (P=0.17). The difference in the two groups could still be clinically significant and the raised IOP in Densiron-68 group was more difficult to treat in some cases.On day 1, nine eyes (12.7%) in the Densiron-68 group and two eyes (3.5%) in the SO group had IOP greater than 30 mmHg. At 4 weeks, IOP of more than 30 mmHg was seen in nine eyes (12.7%) in the Densiron-68-treated group and in one eye (1.8%) in the SO group. The use of Densiron-68 was associated with a higher IOP in the early postoperative period when compared with SO.

  9. Improved algorithm of ray tracing in ICF cryogenic targets

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Yang, Yongying; Ling, Tong; Jiang, Jiabin

    2016-10-01

    The high precision ray tracing inside inertial confinement fusion (ICF) cryogenic targets plays an important role in the reconstruction of the three-dimensional density distribution by algebraic reconstruction technique (ART) algorithm. The traditional Runge-Kutta methods, which is restricted by the precision of the grid division and the step size of ray tracing, cannot make an accurate calculation in the case of refractive index saltation. In this paper, we propose an improved algorithm of ray tracing based on the Runge-Kutta methods and Snell's law of refraction to achieve high tracing precision. On the boundary of refractive index, we apply Snell's law of refraction and contact point search algorithm to ensure accuracy of the simulation. Inside the cryogenic target, the combination of the Runge-Kutta methods and self-adaptive step algorithm are employed for computation. The original refractive index data, which is used to mesh the target, can be obtained by experimental measurement or priori refractive index distribution function. A finite differential method is performed to calculate the refractive index gradient of mesh nodes, and the distance weighted average interpolation methods is utilized to obtain refractive index and gradient of each point in space. In the simulation, we take ideal ICF target, Luneberg lens and Graded index rod as simulation model to calculate the spot diagram and wavefront map. Compared the simulation results to Zemax, it manifests that the improved algorithm of ray tracing based on the fourth-order Runge-Kutta methods and Snell's law of refraction exhibits high accuracy. The relative error of the spot diagram is 0.2%, and the peak-to-valley (PV) error and the root-mean-square (RMS) error of the wavefront map is less than λ/35 and λ/100, correspondingly.

  10. Prevalence of laser vision correction in ophthalmologists who perform refractive surgery.

    PubMed

    Kezirian, Guy M; Parkhurst, Gregory D; Brinton, Jason P; Norden, Richard A

    2015-09-01

    To determine the prevalence of laser corneal refractive surgery (laser vision correction [LVC]) among ophthalmologists who perform these procedures and to assess the willingness of these ophthalmologists to recommend LVC to immediate family members. Online survey with results analyzed at Surgivision Consultants, Inc., Scottsdale, Arizona, USA. Prospective randomized questionnaire study. The 22-question Global Survey on Refractive Surgery in Refractive Surgeons was sent by e-mail to 250 ophthalmologists randomly selected from a database of 2441 ophthalmologists known to have performed LVC at some point in the past decade. Responses were solicited by e-mail, with subsequent telephone reminders to nonresponders. Responses were received from 248 (99.2%) of 250 queried individuals, of which 232 (92.8%) met the protocol criteria of currently working as refractive surgeons. Of the 232 subjects, 161 (69.4%) reported that they had refractive errors potentially amenable to treatment with LVC, not including presbyopia. Of the 161 ophthalmologists with treatable refractive errors, 54 (33.5%) reported they were not candidates for LVC for a variety of reasons and 107 (66.5%) reported they were candidates for LVC. Of the LVC candidates, 62.6% reported that they had an LVC procedure in their own eyes. Of the overall 232 subjects, more than 90% recommend LVC for adult members of their immediate family. Ophthalmologists who perform LVC were significantly more likely than the general population to have LVC in their own eyes. The prevalence of refractive errors was significantly higher among ophthalmologists performing refractive surgery than in the general population. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Cycloplegic autorefraction versus subjective refraction: the Tehran Eye Study.

    PubMed

    Hashemi, Hassan; Khabazkhoob, Mehdi; Asharlous, Amir; Soroush, Sara; Yekta, AbbasAli; Dadbin, Nooshin; Fotouhi, Akbar

    2016-08-01

    To compare cycloplegic autorefraction with non-cycloplegic subjective refraction across all age and refractive error groups. In a cross-sectional study with random stratified cluster sampling, 160 clusters were chosen from various districts proportionate to the population of each district in Tehran. Following retinoscopy and autorefraction with the 0.25 D bracketing (Topcon KR-8000, Topcon, Tokyo, Japan), all participants had a subjective refraction. Then all participants underwent cycloplegic autorefraction. The final analysis was performed on 3482 participants with a mean age of 31.7 years (range 5-92 years). Based on cycloplegic and subjective refraction, mean spherical equivalent (SE) was +0.31±1.80 and -0.32±1.61 D, respectively (p<0.001). The 95% limits of agreement (LoA) between these two types of refraction were from -0.40 to 1.70 D. The largest difference between these two types of refraction was seen in the age group of 5-10 years (1.11±0.60 D), and the smallest difference was in the age group of >70 years (0.34±0.45 D). The 95% LoA was -0.52 to 0.89 D in patients with myopia and -0.12 to 2.04 D in patients with hyperopia. We found that female gender (coefficients=0.048), older age (coefficients=-0.247), higher education (coefficients=-0.043) and cycloplegic SE (coefficients=-0.472) significantly correlated with lower intermethod differences. The cycloplegic refraction is more sensitive than the subjective one to measure refractive error at all age groups especially in children and young adults. The cyclorefraction technique is highly recommended to exactly measure the refractive error in momentous conditions such as refractive surgery, epidemiological researches and amblyopia therapy, especially in hypermetropic eyes and paediatric cases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System.

    PubMed

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-05-25

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction ( p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant ( p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.

  13. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System

    PubMed Central

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-01-01

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking—especially in the treatment of astigmatisms in corneal refractive Excimer laser correction—concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction (p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from −14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant (p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments. PMID:28587100

  14. Combined laser in situ keratomileusis and prophylactic high-fluence corneal collagen crosslinking for high myopia: two-year safety and efficacy.

    PubMed

    Kanellopoulos, Anastasios John; Asimellis, George

    2015-07-01

    To evaluate the safety, efficacy, and refractive and keratometric stability of myopic femtosecond laser in situ keratomileusis (LASIK) with concurrent prophylactic high-fluence corneal collagen crosslinking (CXL) compared with the outcomes of standard femtosecond LASIK. Private clinical practice, Athens, Greece. Consecutive randomized prospective comparative study. Eyes that had myopic LASIK or myopic LASIK with concurrent high-fluence CXL were evaluated preoperatively and up to 2 years postoperatively for manifest refraction spherical equivalent (MRSE), refractive astigmatism, visual acuity, corneal keratometry (K), and endothelial cell count. One hundred forty consecutive eyes had myopic LASIK; 65 of the eyes were treated additionally with CXL. In the LASIK-CXL eyes, the mean postoperative MRSE was -0.18 diopter (D) ± 17.0 (SD) from -6.67 ± 2.14 D preoperatively. The postoperative flat K was 37.67 D from 43.92 D, and the steep K was 38.38 D from 45.15 D. The correlation coefficient of SE correction predictability was 0.975. In the LASIK-only eyes, the mean postoperative MRSE was -0.32 ± 0.24 D from -5.49 ± 1.99 D preoperatively. The flat K was 38.04 D from 43.15 D, and the steep K was 38.69 D from 44.03 D. The correlation coefficient of SE correction predictability was 0.968. The differences between the 2 groups at the 20/20 and 20/25 levels were statistically significant (P = .045 and P = .039, respectively). Two-year results indicate that the application of prophylactic CXL concurrently with high-myopic LASIK appears to improve refractive and keratometric stability, presumably by affecting corneal biomechanical properties. Dr. Kanellopoulos is a consultant to Alcon Surgical, Inc., Wavelight Laser Technologie AG, Allergan, Inc., Avedro, Inc., and i-Optics Corp. Dr. Asimellis has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Laser in situ keratomileusis for high hyperopia with corneal vertex centration and asymmetric offset.

    PubMed

    de Ortueta, Diego; Arba-Mosquera, Sam

    2017-03-10

    To investigate refractive outcomes and induction of corneal higher order aberrations (HOA) in eyes that underwent laser-assisted in situ keratomileusis (LASIK) for high hyperopia correction using an aberration neutral profile with corneal vertex centration and asymmetric offset. A total of 24 consecutive patients (38 eyes) who underwent LASIK by one surgeon using AMARIS 750S excimer laser and a Carriazo-Pendular microkeratome for flap creation were retrospectively analyzed. Eyes targeted for plano and with correction in the maximum hyperopic meridian strictly higher than +4D were included in the retrospective analysis. Patients were reviewed at 1, 3, and 6 months postoperatively. Postoperative monocular corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA), manifest refraction, and corneal wavefront aberrations were compared with respective preoperative metrics. Mean preoperative spherical equivalent and refractive astigmatism was +4.07 ± 0.90 D and 1.37 ± 1.26 D, respectively, reducing to +0.28 ± 0.58D (p<0.0001) and 0.49 ± 0.47 D (p = 0.0001) at the last postoperative visit. Six months postoperatively, 78% of eyes achieved a UDVA of 20/25 or better. No eye lost more than 2 Snellen lines of CDVA at any follow-up. There was a statistically significant induction of vertical trefoil (+0.104 ± 0.299 µm, p<0.05), vertical coma (-0.181 ± 0.463 µm, p<0.01), horizontal coma (+0.198 ± 0.663 µm, p<0.05), spherical aberration (-0.324 ± 0.281 µm, p<0.0001), secondary vertical trefoil (+0.018 ± 0.044 µm, p<0.01), and secondary horizontal coma (+0.026 ± 0.083 µm, p<0.05). Laser-assisted in situ keratomileusis for high hyperopia using corneal vertex centration with asymmetric offset results in significant improvement in refraction and visual acuity although affected by significant induction of some higher order aberrations.

  16. Safety and efficacy of wavefront-guided myopic laser in situ keratomileusis using a new wavefront sensor technology: first 100 cases.

    PubMed

    Smadja, David; Santhiago, Marcony R; Tellouck, Joy; De Castro, Tania; Lecomte, Fanny; Mello, Glauco R; Touboul, David

    2015-08-01

    To evaluate the safety and efficacy of wavefront-guided laser in situ keratomileusis (LASIK) for the correction of low to high myopia and myopic astigmatism using data derived from a new-generation Hartmann-Shack aberrometer. Refractive Surgery Unit, Bordeaux Hospital University, France. Retrospective case series. This retrospective study analyzed the initial group of eyes treated with wavefront-guided LASIK for myopia and myopic astigmatism using the Visx S4IR excimer laser and wavefront data derived from a new Hartmann-Shack aberrometer (iDesign Advanced Wavescan aberrometer). Refractive (refraction and refractive accuracy) and visual outcomes (uncorrected [UDVA] and corrected [CDVA] distance visual acuities) were recorded 3 months postoperatively. The study included 100 eyes of 50 consecutively treated patients. The mean decimal UDVA improved from 0.1 ± 0.1 (SD) preoperatively to 1.1 ± 0.15 postoperatively (P < .01). A monocular UDVA of 20/16, 20/20, and 20/25 were achieved in 76.6%, 94.4%, and 96.6% of eyes, respectively. The postoperative manifest spherical equivalent was within ±0.5 diopter in all eyes. No eye lost 2 or more lines of CDVA, and 29.2% of the eyes gained 1 or more lines of CDVA. Wavefront-guided LASIK performed using data derived from the new Hartmann-Shack aberrometer was safe, effective, and predictable for treating myopia and myopic astigmatism. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.

    PubMed

    Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan

    2017-09-05

    To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.

  18. Correlation between practice location as a surrogate for UV exposure and practice patterns to prevent corneal haze after photorefractive keratectomy (PRK).

    PubMed

    Al-Sharif, Eman M; Stone, Donald U

    2016-01-01

    PRK is a refractive surgery that reshapes the corneal surface by excimer laser photoablation to correct refractive errors. The effect of increased ultraviolet (UV) exposure on promoting post-PRK corneal haze has been reported in the literature; however, information is lacking regarding the effect of ambient UV exposure on physician practice patterns. The aim of this study was to evaluate the effect of ophthalmologists' practice location on their reported practice patterns to prevent post-PRK corneal haze. A cross-sectional observational study was conducted through an online survey sent to ophthalmologists performing PRK. The survey recorded the primary city of practice from which the two independent variables, latitude and average annual sunshine days, were determined. It also measured the frequency of use of postoperative preventive interventions (dependent variables) which are as follows: intraoperative Mitomycin-C, oral vitamin C, sunglasses, topical corticosteroids, topical cyclosporine, oral tetracyclines and amniotic membrane graft. Fifty-one ophthalmologists completed the survey. Practice locations' mean latitude was 36.4 degrees north, and average sunshine days annually accounted for 60% of year days. There was no significant relation between latitude/average annual sunshine days and usual post-PRK prophylactic treatments ( P  > 0.05). The commonest protective maneuvers were sunglasses (78%), prolonged topical corticosteroids (57%), Mitomycin-C (39%) and oral vitamin C (37%). We found no significant difference in ophthalmologists' practice patterns to prevent post-PRK corneal haze in relation to practice location latitude and average sunshine days. Moreover, the results demonstrated that the most widely used postoperative measures to prevent post-PRK haze are sunglasses, Mitomycin-C, topical corticosteroids, and oral Vitamin C.

  19. Correction of Refractive Errors in Rhesus Macaques (Macaca mulatta) Involved in Visual Research

    PubMed Central

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-01-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals. PMID:25427343

  20. Simplified mathematics for customized refractive surgery.

    PubMed

    Preussner, Paul Rolf; Wahl, Jochen

    2003-03-01

    To describe a simple mathematical approach to customized corneal refractive surgery or customized intraocular lens (IOL) design that allows "hypervision" and to investigate the accuracy limits. University eye hospital, Mainz, Germany. Corneal shape and at least 1 IOL surface are approximated by the well-known Cartesian conic section curves (ellipsoid, paraboloid, or hyperboloid). They are characterized by only 2 parameters, the vertex radius and the numerical eccentricity. Residual refraction errors for this approximation are calculated by numerical ray tracing. These errors can be displayed as a 2-dimensional refraction map across the pupil or by blurring the image of a Landolt ring superimposed on the retinal receptor grid, giving an overall impression of the visual outcome. If the eye is made emmetropic for paraxial rays and if the numerical eccentricities of the cornea and lens are appropriately fitted to each other, the residual refractive errors are small enough to allow hypervision. Visual acuity of at least 2.0 (20/10) appears to be possible, particularly for mesopic pupil diameters. However, customized optics may have limited application due to their sensitivity to misalignment errors such as decentrations or rotations. The mathematical approach described by Descartes 350 years ago is adequate to calculate hypervision optics for the human eye. The availability of suitable mathematical tools should, however, not be viewed with too much optimism as long as the accuracy of the implementation in surgical procedures is limited.

  1. Correction of refractive errors in rhesus macaques (Macaca mulatta) involved in visual research.

    PubMed

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-08-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.

  2. Clinical Outcomes of Small Incision Lenticule Extraction with Accelerated Cross-Linking (ReLEx SMILE Xtra) in Patients with Thin Corneas and Borderline Topography

    PubMed Central

    Ganesh, Sri; Brar, Sheetal

    2015-01-01

    Purpose. To study the safety and clinical outcomes of ReLEx SMILE with accelerated cross-linking in individuals with thinner corneas, borderline topography, and higher refractive errors. Methods. Eligible patients first underwent SMILE procedure for correction of myopic refractive error. Following the removal of lenticule, 0.25% riboflavin in saline was injected into the interface and allowed to diffuse for 60 seconds. Finally, eye was exposed to UV-A radiation of 45 mW/cm2 for 75 seconds through the cap. Total energy delivered was 3.4 J/cm2. Results. 40 eyes of 20 patients with mean age of 26.75 ± 5.99 years were treated. Mean follow-up was 12 months ± 28.12 days. Mean spherical equivalent (SE) was −5.02 ± 2.06 D preoperatively and −0.24 ± 0.18 D postoperatively. The mean central corneal thickness (CCT) and keratometry changed from 501 ± 25.90 µm to 415 ± 42.26 µm and 45.40 ± 1.40 D to 41.2 ± 2.75 D, respectively. Mean uncorrected visual acuity (UCVA) was 20/25 or better in all eyes. No eyes lost lines of corrected distant visual acuity (CDVA). There were no complications like haze, keratitis, ectasia, or regression. Conclusion. Based on the initial clinical outcome it appears that SMILE Xtra may be a safe and feasible modality to prevent corneal ectasia in susceptible individuals. PMID:26221538

  3. Clinical Outcomes of Small Incision Lenticule Extraction with Accelerated Cross-Linking (ReLEx SMILE Xtra) in Patients with Thin Corneas and Borderline Topography.

    PubMed

    Ganesh, Sri; Brar, Sheetal

    2015-01-01

    Purpose. To study the safety and clinical outcomes of ReLEx SMILE with accelerated cross-linking in individuals with thinner corneas, borderline topography, and higher refractive errors. Methods. Eligible patients first underwent SMILE procedure for correction of myopic refractive error. Following the removal of lenticule, 0.25% riboflavin in saline was injected into the interface and allowed to diffuse for 60 seconds. Finally, eye was exposed to UV-A radiation of 45 mW/cm(2) for 75 seconds through the cap. Total energy delivered was 3.4 J/cm(2). Results. 40 eyes of 20 patients with mean age of 26.75 ± 5.99 years were treated. Mean follow-up was 12 months ± 28.12 days. Mean spherical equivalent (SE) was -5.02 ± 2.06 D preoperatively and -0.24 ± 0.18 D postoperatively. The mean central corneal thickness (CCT) and keratometry changed from 501 ± 25.90 µm to 415 ± 42.26 µm and 45.40 ± 1.40 D to 41.2 ± 2.75 D, respectively. Mean uncorrected visual acuity (UCVA) was 20/25 or better in all eyes. No eyes lost lines of corrected distant visual acuity (CDVA). There were no complications like haze, keratitis, ectasia, or regression. Conclusion. Based on the initial clinical outcome it appears that SMILE Xtra may be a safe and feasible modality to prevent corneal ectasia in susceptible individuals.

  4. Refractive outcomes after multifocal intraocular lens exchange.

    PubMed

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P < .05). The median absolute refractive prediction error significantly decreased from 0.43 D before the exchange to 0.23 D after the exchange (P < .05). Multifocal IOL exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Laser in situ keratomileusis for residual hyperopic astigmatism after conductive keratoplasty.

    PubMed

    Kymionis, George D; Aslanides, Ioannis M; Khoury, Aghlab N; Markomanolakis, Marinos M; Naoumidi, Tatiana; Pallikaris, loannis G

    2004-01-01

    To report a case of laser in situ keratomileusis (LASIK) in a patient with previous conductive keratoplasty. A 48-year-old man underwent conductive keratoplasty for low hyperopic astigmatism (manifest refraction OD: +2.25 -0.50 x 77 degrees; OS: +2.50 -0.50 x 105 degrees). Three months postoperatively, UCVA was 20/25 and BSCVA was 20/20 in both eyes; manifest refraction OD: -0.25 -0.75 x 110 degrees; OS: +0.75 -0.75 x 50 degrees. Sixteen months after the operation, regression of refractive outcome was (manifest) OD: +1.75 -1.25 x 90 degrees; OS: +2.50 -0.50 x 85 degrees; UCVA was 20/40 in the right eye and 20/63 in the left eye and BSCVA was 20/20 in both eyes. LASIK was performed for hyperopic regression in the left eye using an automated microkeratome (Alcon SKBM, 130-microm plate; Aesculap-Meditec MEL 70 excimer laser). LASIK was uneventful and no intraoperative or postoperative complications related to the previous conductive keratoplasty procedure or LASIK were observed. Three months after LASIK and 19 months after the initial conductive keratoplasty, the patient's left eye was emmetropic; UCVA was 20/20(-2), BSCVA was 20/20 and manifest refraction was +0.25 -0.25 x 35 degrees. There was a uniform increase in topographical steepening. Visual acuity, refraction and topographic findings remained unchanged at 6 months. Even though our experience is limited, treatment of hyperopia with LASIK in an eye with refractive regression following previous conductive keratoplasty resulted in a predicted refractive outcome, with no complications, and improvement in visual acuity at 6 months follow-up.

  6. Comparative Study of Refractive Errors, Strabismus, Microsaccades, and Visual Perception Between Preterm and Full-Term Children With Infantile Cerebral Palsy.

    PubMed

    Kozeis, Nikolaos; Panos, Georgios D; Zafeiriou, Dimitrios I; de Gottrau, Philippe; Gatzioufas, Zisis

    2015-07-01

    The purpose of this study was to examine the refractive status, orthoptic status and visual perception in a group of preterm and another of full-term children with cerebral palsy, in order to investigate whether prematurity has an effect on the development of refractive errors and binocular disorders. A hundred school-aged children, 70 preterm and 30 full-term, with congenital cerebral palsy were examined. Differences for hypermetropia, myopia, and emmetropia were not statistically significant between the 2 groups. Astigmatism was significantly increased in the preterm group. The orthoptic status was similar for both groups. Visual perception was markedly reduced in both groups, but the differences were not significant. In conclusion, children with cerebral palsy have impaired visual skills, leading to reading difficulties. The presence of prematurity does not appear to represent an additional risk factor for the development of refractive errors and binocular disorders. © The Author(s) 2014.

  7. Region-Specific Relationships Between Refractive Error and Ciliary Muscle Thickness in Children

    PubMed Central

    Pucker, Andrew D.; Sinnott, Loraine T.; Kao, Chiu-Yen; Bailey, Melissa D.

    2013-01-01

    Purpose. To determine if there is a relationship between refractive error and ciliary muscle thickness in different muscle regions. Methods. An anterior segment optical coherence tomographer was used to measure cycloplegic ciliary muscle thicknesses at 1 mm (CMT1), 2 mm (CMT2), and 3 mm (CMT3) posterior to the scleral spur; maximum (CMTMAX) thickness was also assessed. An autorefractor was used to determine cycloplegic spherical equivalent refractive error (SPHEQ). Apical ciliary muscle fibers were obtained by subtracting corresponding CMT2 values from CMT1 and CMTMAX. Multilevel regression models were used to determine the relationship between ciliary muscle thickness in various regions of the muscle and refractive error. Results. Subjects included 269 children with a mean age of 8.71 ± 1.51 years and a mean refractive error of +0.41 ± 1.29 diopters. In linear models with ciliary muscle thicknesses and SPHEQ, SPHEQ was significantly associated only with CMT2 (β = −11.34, P = 0.0008) and CMT 3 (β = −6.97, P = 0.007). When corresponding values of CMT2 were subtracted from CMT1 and CMTMAX, apical fibers at CMT1 (β = 14.75, P < 0.0001) and CMTMAX (β = 18.16, P < 0.0001) had a significant relationship with SPHEQ. Conclusions. These data indicated that in children the posterior ciliary muscle fibers are thicker in myopia (CMT2 and CMT3), but paradoxically, the apical ciliary muscle fibers are thicker in hyperopia (CMTMAX and CMT1). This may be the first evidence that hyperopia is associated with a thicker apical ciliary muscle region. PMID:23761093

  8. Visual disability, visual function, and myopia among rural chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES)--report 1.

    PubMed

    Congdon, Nathan; Wang, Yunfei; Song, Yue; Choi, Kai; Zhang, Mingzhi; Zhou, Zhongxia; Xie, Zhenling; Li, Liping; Liu, Xueyu; Sharma, Abhishek; Wu, Bin; Lam, Dennis S C

    2008-07-01

    To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (< or = 6/12 in the better eye) was 41.2%, 19.3%, and 0.5%, respectively. Myopia < -0.5, < -2.0, and < -6.0 D in both eyes was present in 62.3%, 31.1%, and 1.9% of the subjects, respectively. Among the children with visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P < 0.001) more presenting visual disability and myopia < -2.0 D than did the boys. More myopic refractive error was associated with worse self-reported visual function (ANOVA trend test, P < 0.001). Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.

  9. Ionospheric refraction effects on orbit determination using the orbit determination error analysis system

    NASA Technical Reports Server (NTRS)

    Yee, C. P.; Kelbel, D. A.; Lee, T.; Dunham, J. B.; Mistretta, G. D.

    1990-01-01

    The influence of ionospheric refraction on orbit determination was studied through the use of the Orbit Determination Error Analysis System (ODEAS). The results of a study of the orbital state estimate errors due to the ionospheric refraction corrections, particularly for measurements involving spacecraft-to-spacecraft tracking links, are presented. In current operational practice at the Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF), the ionospheric refraction effects on the tracking measurements are modeled in the Goddard Trajectory Determination System (GTDS) using the Bent ionospheric model. While GTDS has the capability of incorporating the ionospheric refraction effects for measurements involving ground-to-spacecraft tracking links, such as those generated by the Ground Spaceflight Tracking and Data Network (GSTDN), it does not have the capability to incorporate the refraction effects for spacecraft-to-spacecraft tracking links for measurements generated by the Tracking and Data Relay Satellite System (TDRSS). The lack of this particular capability in GTDS raised some concern about the achievable accuracy of the estimated orbit for certain classes of spacecraft missions that require high-precision orbits. Using an enhanced research version of GTDS, some efforts have already been made to assess the importance of the spacecraft-to-spacecraft ionospheric refraction corrections in an orbit determination process. While these studies were performed using simulated data or real tracking data in definitive orbit determination modes, the study results presented here were obtained by means of covariance analysis simulating the weighted least-squares method used in orbit determination.

  10. A novel navigation method used in a ballistic missile

    NASA Astrophysics Data System (ADS)

    Qian, Hua-ming; Sun, Long; Cai, Jia-nan; Peng, Yu

    2013-10-01

    The traditional strapdown inertial/celestial integrated navigation method used in a ballistic missile cannot accurately estimate the accelerometer bias. It might cause a divergence of navigation errors. To solve this problem, a new navigation method named strapdown inertial/starlight refractive celestial integrated navigation is proposed. To verify the feasibility of the proposed method, a simulated program of a ballistic missile is presented. The simulation results indicated that, when multiple refraction stars are used, the proposed method can accurately estimate the accelerometer bias, and suppress the divergence of navigation errors completely. Specifically, in order to apply this method to a ballistic missile, a novel measurement equation based on stellar refraction was developed. Furthermore a method to calculate the number of refraction stars observed by the stellar sensor was given. Finally, the relationship between the number of refraction stars used and the navigation accuracy is analysed.

  11. The refractive index in electron microscopy and the errors of its approximations.

    PubMed

    Lentzen, M

    2017-05-01

    In numerical calculations for electron diffraction often a simplified form of the electron-optical refractive index, linear in the electric potential, is used. In recent years improved calculation schemes have been proposed, aiming at higher accuracy by including higher-order terms of the electric potential. These schemes start from the relativistically corrected Schrödinger equation, and use a second simplified form, now for the refractive index squared, being linear in the electric potential. The second and higher-order corrections thus determined have, however, a large error, compared to those derived from the relativistically correct refractive index. The impact of the two simplifications on electron diffraction calculations is assessed through numerical comparison of the refractive index at high-angle Coulomb scattering and of cross-sections for a wide range of scattering angles, kinetic energies, and atomic numbers. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. [Correction of refractive errors in patients with strabismus. Part I. Clinical problems associated with refraction, accommodation and convergence].

    PubMed

    Tokarz-Sawińska, Ewa

    2012-01-01

    In Part I the problems associated with refraction, accommodation and convergence and their role in proper eye position/visual alignment of the eyes as well as convergent, divergent and vertical alignment of the eyes have been described.

  13. Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and ≤3 dioptres of astigmatism.

    PubMed

    Lam, Douglas K T; Chow, Vanissa W S; Ye, Cong; Ng, Paul Ka-Fai; Wang, Zheng; Jhanji, Vishal

    2016-02-01

    To compare the visual outcomes of aspheric toric intraocular lens (IOL) implantation and limbal relaxing incisions (LRI) for management of coexisting age-related cataracts and astigmatism. In this prospective study, sixty eyes of 60 patients with visually significant cataract and coexisting corneal astigmatism ≤3 dioptres (D) were randomised to undergo phacoemulsification with either aspheric toric IOL or aspheric monofocal IOL with LRI. The main outcome measures were postoperative 3-month uncorrected visual acuity (UCVA), contrast sensitivity, rotational stability of the toric IOL and spectacle independence. The postoperative UCVA, contrast sensitivity and refractive astigmatism were significantly better than the baseline measurements for both groups (p≤0.001). There was no significant difference detected for these parameters between LRI and toric IOL groups postoperatively (p≥0.119). At both postoperative month 1 and 3, the percentages of eyes in need of spectacles were lower in toric group than LRI group (p≤0.030). IOL misalignment was noted in three eyes in the toric IOL group (mean misalignment 7.67±4.04°). On vector analysis, magnitude of error (ME) was negative in the LRI group indicating undercorrection, whereas the ME was close to zero for toric group. Both toric IOL implantation and LRI were effective in correcting corneal astigmatism ≤3 D during phacoemulsification, while LRI tended to undercorrect astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Microwave Resonator Measurements of Atmospheric Absorption Coefficients: A Preliminary Design Study

    NASA Technical Reports Server (NTRS)

    Walter, Steven J.; Spilker, Thomas R.

    1995-01-01

    A preliminary design study examined the feasibility of using microwave resonator measurements to improve the accuracy of atmospheric absorption coefficients and refractivity between 18 and 35 GHz. Increased accuracies would improve the capability of water vapor radiometers to correct for radio signal delays caused by Earth's atmosphere. Calibration of delays incurred by radio signals traversing the atmosphere has applications to both deep space tracking and planetary radio science experiments. Currently, the Cassini gravity wave search requires 0.8-1.0% absorption coefficient accuracy. This study examined current atmospheric absorption models and estimated that current model accuracy ranges from 5% to 7%. The refractivity of water vapor is known to 1% accuracy, while the refractivity of many dry gases (oxygen, nitrogen, etc.) are known to better than 0.1%. Improvements to the current generation of models will require that both the functional form and absolute absorption of the water vapor spectrum be calibrated and validated. Several laboratory techniques for measuring atmospheric absorption and refractivity were investigated, including absorption cells, single and multimode rectangular cavity resonators, and Fabry-Perot resonators. Semi-confocal Fabry-Perot resonators were shown to provide the most cost-effective and accurate method of measuring atmospheric gas refractivity. The need for accurate environmental measurement and control was also addressed. A preliminary design for the environmental control and measurement system was developed to aid in identifying significant design issues. The analysis indicated that overall measurement accuracy will be limited by measurement errors and imprecise control of the gas sample's thermodynamic state, thermal expansion and vibration- induced deformation of the resonator structure, and electronic measurement error. The central problem is to identify systematic errors because random errors can be reduced by averaging. Calibrating the resonator measurements by checking the refractivity of dry gases which are known to better than 0.1% provides a method of controlling the systematic errors to 0.1%. The primary source of error in absorptivity and refractivity measurements is thus the ability to measure the concentration of water vapor in the resonator path. Over the whole thermodynamic range of interest the accuracy of water vapor measurement is 1.5%. However, over the range responsible for most of the radio delay (i.e. conditions in the bottom two kilometers of the atmosphere) the accuracy of water vapor measurements ranges from 0.5% to 1.0%. Therefore the precision of the resonator measurements could be held to 0.3% and the overall absolute accuracy of resonator-based absorption and refractivity measurements will range from 0.6% to 1.

  15. Polar Value Analysis of Low to Moderate Astigmatism with Wavefront-Guided Sub-Bowman Keratomileusis

    PubMed Central

    Zhang, Yu

    2017-01-01

    Purpose To evaluate the astigmatic outcomes of wavefront-guided sub-Bowman keratomileusis (WFG-SBK) for low to moderate myopic astigmatism. Methods This study enrolled 100 right eyes from 100 patients who underwent WFG-SBK for the correction of myopia and astigmatism. The polar value method was performed with anterior and posterior corneal astigmatism measured with Scheimpflug camera combined with Placido corneal topography (Sirius, CSO) and refractive astigmatism preoperatively and 1 month, 3 months, and 6 months postoperatively. Results Similar results for surgically induced astigmatism (SIA) and error of the procedure in both anterior corneal astigmatism (ACA) and total ocular astigmatism (TOA). There was a minor undercorrection of the cylinder in both ACA and TOA. Posterior corneal astigmatism (PCA) showed no significant change. Conclusions Wavefront-guided SBK could provide good astigmatic outcomes for the correction of low to moderate myopic astigmatism. The surgical effects were largely attributed to the astigmatic correction of the anterior corneal surface. Posterior corneal astigmatism remained unchanged even after WFG-SBK for myopic astigmatism. Polar value analysis can be used to guide adjustments to the treatment cylinder alongside a nomogram designed to optimize postoperative astigmatic outcomes in myopic WFG-SBK. PMID:28831306

  16. Image processing and analysis using neural networks for optometry area

    NASA Astrophysics Data System (ADS)

    Netto, Antonio V.; Ferreira de Oliveira, Maria C.

    2002-11-01

    In this work we describe the framework of a functional system for processing and analyzing images of the human eye acquired by the Hartmann-Shack technique (HS), in order to extract information to formulate a diagnosis of eye refractive errors (astigmatism, hypermetropia and myopia). The analysis is to be carried out using an Artificial Intelligence system based on Neural Nets, Fuzzy Logic and Classifier Combination. The major goal is to establish the basis of a new technology to effectively measure ocular refractive errors that is based on methods alternative those adopted in current patented systems. Moreover, analysis of images acquired with the Hartmann-Shack technique may enable the extraction of additional information on the health of an eye under exam from the same image used to detect refraction errors.

  17. [Extreme (complicated, ultra-high) refractive errors: terminological misconceptions!?

    PubMed

    Avetisov, S E

    2018-01-01

    The article reviews development mechanisms of different refractive errors accompanied by marked defocus of light rays reaching the retina. Terminology used for such ametropias includes terms extreme, ultra-high and complicated. Justification of their usage for primary ametropias, whose symptom complex is based on changes in axial eye length, is an ongoing discussion. To comply with thesaurus definitions of 'diagnosis' and 'pathogenesis', to characterize refractive and anatomical-functional disorders in patients with primary ametropias it is proposed to use the terms 'hyperaxial and hypoaxial syndromes' with elaboration of specific symptoms instead of such expressions as extreme (ultra-high) myopia and hypermetropia.

  18. Racial Variations in the Prevalence of Refractive Errors in the United States: The Multi-Ethnic Study of Atherosclerosis

    PubMed Central

    PAN, CHEN-WEI; KLEIN, BARBARA E.K.; COTCH, MARY FRANCES; SHRAGER, SANDI; KLEIN, RONALD; FOLSOM, AARON; KRONMAL, RICHARD; SHEA, STEVEN J.; BURKE, GREGORY L.; SAW, SEANG-MEI; WONG, TIEN Y.

    2013-01-01

    PURPOSE To describe racial variations in the prevalence of refractive errors among adult white, Chinese, Hispanic, and black subjects in the United States. DESIGN Cross-sectional data from a prospective cohort study—the Multi-Ethnic Study of Atherosclerosis (MESA). METHODS A total of 6000 adults aged 45 to 84 years living in the United States participated in the study. Refractive error was assessed, without cycloplegia, in both eyes of all participants using an autorefractor. After excluding eyes with cataract, cataract surgery, or previous refractive surgery, the eye with the larger absolute spherical equivalent (SE) value for each participant was used to classify refractive error. Any myopia was defined as SE of −1.0 diopters (D) or less; high myopia was defined as SE of −5.0 D or less; any hyperopia was defined as SE of +1.0 D or more; clinically significant hyperopia was defined as SE of +3.0 D or more. Astigmatism was defined as a cylinder value of +1.0 D or more. RESULTS After excluding 508 participants with cataracts in both eyes, 838 participants with cataract surgery, 90 participants with laser refractive surgery, and 134 participants who refused to remove their contact lenses for the refraction measurement, 4430 adults with refractive error assessment in at least 1 eye contributed to the analysis. The prevalence of myopia among MESA participants was 25.1%, with lowest rates in Hispanic participants (14.2%), followed by black (21.5%) and white participants (31.0%), and highest rates in Chinese participants (37.2%). The overall rates of high myopia and astigmatism were 4.6% and 45.0%, respectively, with Chinese subjects also having the highest rates of high myopia (11.8%) and astigmatism (53.4%). The overall prevalence of any hyperopia was 38.2% and clinically significant hyperopia was 6.1%, with Hispanic participants having the highest rates of hyperopia (50.2%) and clinically significant hyperopia (8.8%). In multivariate analyses adjusting for age, sex, race, and study site, higher education level, being employed, and being taller were associated with a higher prevalence of myopia. In contrast, lower educational level and being shorter were associated with a higher prevalence of hyperopia. CONCLUSIONS Myopia and astigmatism were most prevalent in the Chinese population, with Chinese subjects having 3 times the prevalence of myopia as Hispanic subjects. Hyperopia was most common in Hispanic subjects. These findings provide further insights into variations in refractive errors among different racial groups and have important implications for the eye care services in the United States. PMID:23453694

  19. Racial variations in the prevalence of refractive errors in the United States: the multi-ethnic study of atherosclerosis.

    PubMed

    Pan, Chen-Wei; Klein, Barbara E K; Cotch, Mary Frances; Shrager, Sandi; Klein, Ronald; Folsom, Aaron; Kronmal, Richard; Shea, Steven J; Burke, Gregory L; Saw, Seang-Mei; Wong, Tien Y

    2013-06-01

    To describe racial variations in the prevalence of refractive errors among adult white, Chinese, Hispanic, and black subjects in the United States. Cross-sectional data from a prospective cohort study-the Multi-Ethnic Study of Atherosclerosis (MESA). A total of 6000 adults aged 45 to 84 years living in the United States participated in the study. Refractive error was assessed, without cycloplegia, in both eyes of all participants using an autorefractor. After excluding eyes with cataract, cataract surgery, or previous refractive surgery, the eye with the larger absolute spherical equivalent (SE) value for each participant was used to classify refractive error. Any myopia was defined as SE of -1.0 diopters (D) or less; high myopia was defined as SE of -5.0 D or less; any hyperopia was defined as SE of +1.0 D or more; clinically significant hyperopia was defined as SE of +3.0 D or more. Astigmatism was defined as a cylinder value of +1.0 D or more. After excluding 508 participants with cataracts in both eyes, 838 participants with cataract surgery, 90 participants with laser refractive surgery, and 134 participants who refused to remove their contact lenses for the refraction measurement, 4430 adults with refractive error assessment in at least 1 eye contributed to the analysis. The prevalence of myopia among MESA participants was 25.1%, with lowest rates in Hispanic participants (14.2%), followed by black (21.5%) and white participants (31.0%), and highest rates in Chinese participants (37.2%). The overall rates of high myopia and astigmatism were 4.6% and 45.0%, respectively, with Chinese subjects also having the highest rates of high myopia (11.8%) and astigmatism (53.4%). The overall prevalence of any hyperopia was 38.2% and clinically significant hyperopia was 6.1%, with Hispanic participants having the highest rates of hyperopia (50.2%) and clinically significant hyperopia (8.8%). In multivariate analyses adjusting for age, sex, race, and study site, higher education level, being employed, and being taller were associated with a higher prevalence of myopia. In contrast, lower educational level and being shorter were associated with a higher prevalence of hyperopia. Myopia and astigmatism were most prevalent in the Chinese population, with Chinese subjects having 3 times the prevalence of myopia as Hispanic subjects. Hyperopia was most common in Hispanic subjects. These findings provide further insights into variations in refractive errors among different racial groups and have important implications for the eye care services in the United States. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 3: the results of 50 treated eyes

    PubMed Central

    Motwani, Manoj

    2017-01-01

    Purpose To demonstrate how using the Wavelight Contoura measured astigmatism and axis eliminates corneal astigmatism and creates uniformly shaped corneas. Patients and methods A retrospective analysis was conducted of the first 50 eyes to have bilateral full WaveLight® Contoura LASIK correction of measured astigmatism and axis (vs conventional manifest refraction), using the Layer Yolked Reduction of Astigmatism Protocol in all cases. All patients had astigmatism corrected, and had at least 1 week of follow-up. Accuracy to desired refractive goal was assessed by postoperative refraction, aberration reduction via calculation of polynomials, and postoperative visions were analyzed as a secondary goal. Results The average difference of astigmatic power from manifest to measured was 0.5462D (with a range of 0–1.69D), and the average difference of axis was 14.94° (with a range of 0°–89°). Forty-seven of 50 eyes had a goal of plano, 3 had a monovision goal. Astigmatism was fully eliminated from all but 2 eyes, and 1 eye had regression with astigmatism. Of the eyes with plano as the goal, 80.85% were 20/15 or better, and 100% were 20/20 or better. Polynomial analysis postoperatively showed that at 6.5 mm, the average C3 was reduced by 86.5% and the average C5 by 85.14%. Conclusions Using WaveLight® Contoura measured astigmatism and axis removes higher order aberrations and allows for the creation of a more uniform cornea with accurate removal of astigmatism, and reduction of aberration polynomials. WaveLight® Contoura successfully links the refractive correction layer and aberration repair layer using the Layer Yolked Reduction of Astigmatism Protocol to demonstrate how aberration removal can affect refractive correction. PMID:28553071

  1. Characteristics of Refractive Errors in a Population of Adults in the Central Region of Poland.

    PubMed

    Nowak, Michal S; Jurowski, Piotr; Grzybowski, Andrzej; Smigielski, Janusz

    2018-01-08

    Background : To investigate the distribution of refractive errors and their characteristics in older adults from a Polish population. Methods : The study design was a cross-sectional study. A total of 1107 men and women were interviewed and underwent detailed ophthalmic examinations, 998 subjects underwent refraction. Myopia was defined as spherical equivalent (SER) refraction ≤-0.5 dioptres (D) and hyperopia was defined as SER ≥+0.5 dioptres (D). Results : Among those who were refracted the distribution of myopia and hyperopia was 24.1% (95% CI 21.4-26.7) and 37.5% (95% CI 34.5-40.5), respectively. Myopia decreased from 28.7% in subjects aged 35-59 years to 19.3% in those aged 60 years or older and hyperopia increased from 21.8% at 35-59 years of age to 53.3% in subjects aged ≥60 years. Multiple regression analysis showed decreasing age (OR 0.98, 95% CI 0.96-1.00), female gender (OR 1.87, 95% CI 1.18-2.95) and presence of cataract (OR 2.40, 95% CI 1.24-4.63) were independent risk factors associated with myopia. Conclusions : The distribution of refractive errors found in our study is similar to those reported in other Caucasian populations and differs from Asian populations. Myopia was positively associated with younger age, female gender and presence of cataract.

  2. Childhood exposure to constricted living space: a possible environmental threat for myopia development.

    PubMed

    Choi, Kai Yip; Yu, Wing Yan; Lam, Christie Hang I; Li, Zhe Chuang; Chin, Man Pan; Lakshmanan, Yamunadevi; Wong, Francisca Siu Yin; Do, Chi Wai; Lee, Paul Hong; Chan, Henry Ho Lung

    2017-09-01

    People in Hong Kong generally live in a densely populated area and their homes are smaller compared with most other cities worldwide. Interestingly, East Asian cities with high population densities seem to have higher myopia prevalence, but the association between them has not been established. This study investigated whether the crowded habitat in Hong Kong is associated with refractive error among children. In total, 1075 subjects [Mean age (S.D.): 9.95 years (0.97), 586 boys] were recruited. Information such as demographics, living environment, parental education and ocular status were collected using parental questionnaires. The ocular axial length and refractive status of all subjects were measured by qualified personnel. Ocular axial length was found to be significantly longer among those living in districts with a higher population density (F 2,1072  = 6.15, p = 0.002) and those living in a smaller home (F 2,1072  = 3.16, p = 0.04). Axial lengths were the same among different types of housing (F 3,1071  = 1.24, p = 0.29). Non-cycloplegic autorefraction suggested a more negative refractive error in those living in districts with a higher population density (F 2,1072  = 7.88, p < 0.001) and those living in a smaller home (F 2,1072  = 4.25, p = 0.02). After adjustment for other confounding covariates, the population density and home size also significantly predicted axial length and non-cycloplegic refractive error in the multiple linear regression model, while axial length and refractive error had no relationship with types of housing. Axial length in children and childhood refractive error were associated with high population density and small home size. A constricted living space may be an environmental threat for myopia development in children. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  3. Improved silica-PLC Mach-Zehnder interferometer type optical switches with error dependence compensation of directional coupler

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Yi, Jia; Guo, Lijun; Liu, Peng; Hall, Trevor J.; Sun, DeGui

    2017-03-01

    For the most popular structure of planer lightwave circuit (PLC) 2×2 thermo-optic switches, Mach-Zehnder interferometer (MZI), a full range of splitting ratio errors of directional coupler (DC) are investigated. All the parameters determining the splitting ratio are the dimensions and the refractive indices of the waveguide core and cladding layers. In this work, the coherent relationships between the waveguide size and the refractive indices are analyzed and then the error compensation between the width and the refractive index of waveguide core, and the controllable effect of over clad layer refractive index error upon the MZI-type optical switch are all discovered with numerical calculation and BPM simulations. Then, an MZI-type 2×2 thermo-optic switch having a higher error tolerance is established with the efficient optimizations of all the 3 dB-DC parameters. As a result, for the symmetric MZI switch, an insertion loss of 1.5 dB and optical extinction ratio of over 20 dB are realized for the average tolerance of±5.0%. An asymmetric arm optical phase and unequal arm lengths is also employed to improve the uniformities of insertion loss. The agreements between the designs and the experiments are recognized, leading to a wide adoption of practical silica-PLC optical switch products.

  4. Reversible Femtosecond Laser-Assisted Myopia Correction: A Non-Human Primate Study of Lenticule Re-Implantation after Refractive Lenticule Extraction

    PubMed Central

    Chaurasia, Shyam S.; Lee, Wing S.; Tan, Donald T.; Mehta, Jodhbir S.

    2013-01-01

    LASIK (laser-assisted in situ keratomileusis) is a common laser refractive procedure for myopia and astigmatism, involving permanent removal of anterior corneal stromal tissue by excimer ablation beneath a hinged flap. Correction of refractive error is achieved by the resulting change in the curvature of the cornea and is limited by central corneal thickness, as a thin residual stromal bed may result in biomechanical instability of the cornea. A recently developed alternative to LASIK called Refractive Lenticule Extraction (ReLEx) utilizes solely a femtosecond laser (FSL) to incise an intrastromal refractive lenticule (RL), which results in reshaping the corneal curvature and correcting the myopia and/or astigmatism. As the RL is extracted intact in the ReLEx, we hypothesized that it could be cryopreserved and re-implanted at a later date to restore corneal stromal volume, in the event of keratectasia, making ReLEx a potentially reversible procedure, unlike LASIK. In this study, we re-implanted cryopreserved RLs in a non-human primate model of ReLEx. Mild intrastromal haze, noted during the first 2 weeks after re-implantation, subsided after 8 weeks. Refractive parameters including corneal thickness, anterior curvature and refractive error indices were restored to near pre-operative values after the re-implantation. Immunohistochemistry revealed no myofibroblast formation or abnormal collagen type I expression after 8 weeks, and a significant attenuation of fibronectin and tenascin expression from week 8 to 16 after re-implantation. In addition, keratocyte re-population could be found along the implanted RL interfaces. Our findings suggest that RL cryopreservation and re-implantation after ReLEx appears feasible, suggesting the possibility of potential reversibility of the procedure, and possible future uses of RLs in treating other corneal disorders and refractive errors. PMID:23826194

  5. Near work, outdoor activity, and their association with refractive error.

    PubMed

    Lin, Zhong; Vasudevan, Balamurali; Jhanji, Vishal; Mao, Guang Yun; Gao, Tie Ying; Wang, Feng Hua; Rong, Shi Song; Ciuffreda, Kenneth J; Liang, Yuan Bo

    2014-04-01

    To assess the relationship between near work, outdoor activity, and refractive error in schoolchildren in Beijing. The Beijing Myopia Progression Study is a hospital-based myopia study, in which 386 students from primary (aged 6 to 12 years) and secondary (aged 13 to 17 years) schools in the inner city of Beijing were enrolled. Cycloplegic refraction and a detailed questionnaire probing near, intermediate, and distance visual activities were completed. Three hundred seventy (95.9%) of 386 students with complete cycloplegic autorefraction and myopia questionnaire data were enrolled in this study. Children with more near work time did not exhibit a significantly more myopic refraction in both the primary and secondary school levels after adjusting for the children's gender, outdoor activity time, and average parental refractive error. A significant association between outdoor activity time (in hours per day) and the children's spherical equivalent (in diopters) was found in the primary school students (β = 0.27, p = 0.03) but not in the secondary school students (β = 0.04, p = 0.70) after adjusting for similar confounders. The time spent on outdoor sports and outdoor leisure in the primary school students was also significantly associated with the children's spherical equivalent (β = 0.46, p = 0.04 and β = 0.31, p = 0.02, respectively). Primary school students with more time outdoors exhibited relatively less myopic refraction than their peers (ptrend = 0.0003), but this relation was not demonstrated in the secondary school children (ptrend = 0.53) after adjusting for similar confounders. Higher levels of outdoor activity were associated with less myopic refraction in primary school students in the inner city of Beijing. Near work activity was not found to be associated with refraction at either school level.

  6. Knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city, Northwest Ethiopia

    PubMed Central

    2018-01-01

    Introduction Refractive error is an important cause of correctable visual impairment in the worldwide with a global distribution of 1.75% to 20.7% among schoolchildren. Teacher’s knowledge about refractive error play an important role in encouraging students to seek treatment that helps in reducing the burden of visual impairment. Objective To determine knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city. Methods Institution based cross-sectional study was conducted on 565 primary school teachers in Gondar city using pretested and structured self-administered questionnaire. For processing and analysis, SPSS version 20 was used and variables which had a P value of <0.05 in the multivariable analysis were considered as statistically significant. Result A total of 565 study subjects were participated in this study with a mean age of 42.05 ± 12.01 years. Of these study participants 55.9% (95% CI: 51.9, 59.8) had good knowledge and 57.2% (95% CI: 52.9, 61.4) had favorable attitude towards refractive error. History of spectacle use [AOR = 2.13 (95% CI: 1.32, 3.43)], history of eye examination [AOR = 1.67 (95% CI: 1.19, 2.34)], training on eye health [AOR = 1.94 (95% CI; 1.09, 3.43)] and 11–20 years of experience [AOR = 2.53 (95% CI: 1.18, 5.43)] were positively associated with knowledge. Whereas being male [AOR = 2.03 (95% CI: 1.37, 3.01)], older age [AOR = 3.05 (95% CI: 1.07, 8.72)], 31–40 years of experience [AOR = 0.23 (95% CI: 0.07, 0.72)], private school type [AOR = 1.76 (95% CI: 1.06, 2.93)] and 5th -8th teaching category [AOR = 1.54 (95% CI: 1.05, 2.24)] were associated with attitude. Conclusion Knowledge and attitude of study subjects were low which needs training of teachers about the refractive error. PMID:29447172

  7. Uncorrected refractive error and associated factors among primary school children in Debre Markos District, Northwest Ethiopia

    PubMed Central

    2014-01-01

    Background Uncorrected Refractive Error is one of the leading cause amblyopia that exposes children to poor school performance. It refrain them from productive working lives resulting in severe economic and social loses in their latter adulthood lives. The objective of the study was to assess the prevalence of uncorrected refractive error and its associated factors among school children in Debre Markos District. Method A cross section study design was employed. Four hundred thirty two students were randomly selected using a multistage stratified sampling technique. The data were collected by trained ophthalmic nurses through interview, structured questionnaires and physical examinations. Snellens visual acuity measurement chart was used to identify the visual acuity of students. Students with visual acuity less than 6/12 had undergone further examination using auto refractor and cross-checked using spherical and cylindrical lenses. The data were entered into epi data statistical software version 3.1 and analyzed by SPSS version 20. The statistical significance was set at α ≤ 0.05. Descriptive, bivariate and multivariate analyses were done using odds ratios with 95% confidence interval. Result Out of 432 students selected for the study, 420 (97.2%) were in the age group 7–15 years. The mean age was 12 ± 2.1SD. Overall prevalence of refractive error was 43 (10.2%). Myopia was found among the most dominant 5.47% followed by astigmatism 1.9% and hyperopia 1.4% in both sexes. Female sex (AOR: 3.96, 95% CI: 1.55-10.09), higher grade level (AOR: 4.82, 95% CI: 1.98-11.47) and using computers regularly (AOR: 4.53, 95% CI: 1.58-12.96) were significantly associated with refractive error. Conclusion The burden of uncorrected refractive errors is high among primary schools children. Myopia was common in both sexes. The potential risk factors were sex, regular use of computers and higher grade level of students. Hence, school health programs should work on health information dissemination and eye health care services provision. PMID:25070579

  8. Refractive Errors in Koreans: The Korea National Health and Nutrition Examination Survey 2008-2012.

    PubMed

    Rim, Tyler Hyungtaek; Kim, Seung-Hyun; Lim, Key Hwan; Choi, Moonjung; Kim, Hye Young; Baek, Seung-Hee

    2016-06-01

    Our study provides epidemiologic data on the prevalence of refractive errors in all age group ≥5 years in Korea. In 2008 to 2012, a total of 33,355 participants aged ≥5 years underwent ophthalmologic examinations. Using the right eye, myopia was defined as a spherical equivalent (SE) less than -0.5 or -1.0 diopters (D) in subjects aged 19 years and older or as an SE less than -0.75 or -1.25 D in subjects aged 5 to 18 years according to non-cycloplegic refraction. Other refractive errors were defined as follows: high myopia as an SE less than -6.0 D; hyperopia as an SE larger than +0.5 D; and astigmatism as a cylindrical error less than -1.0 D. The prevalence and risk factors of myopia were evaluated. Prevalence rates with a 95% confidence interval were determined for myopia (SE <-0.5 D, 51.9% [51.2 to 52.7]; SE <-1.0 D, 39.6% [38.8 to 40.3]), high myopia (5.0% [4.7 to 5.3]), hyperopia (13.4% [12.9 to 13.9]), and astigmatism (31.2% [30.5 to 32.0]). The prevalence of myopia demonstrated a nonlinear distribution with the highest peak between the ages of 19 and 29 years. The prevalence of hyperopia decreased with age in subjects aged 39 years or younger and then increased with age in subjects aged 40 years or older. The prevalence of astigmatism gradually increased with age. Education was associated with all refractive errors; myopia was more prevalent and hyperopia and astigmatism were less prevalent in the highly educated groups. In young generations, the prevalence of myopia in Korea was much higher compared to the white or black populations in Western countries and is consistent with the high prevalence found in most other Asian countries. The overall prevalence of hyperopia was much lower compared to that of the white Western population. Age and education level were significant predictive factors associated with all kinds of refractive errors.

  9. Refractive Errors in Koreans: The Korea National Health and Nutrition Examination Survey 2008-2012

    PubMed Central

    Rim, Tyler Hyungtaek; Kim, Seung-Hyun; Lim, Key Hwan; Choi, Moonjung

    2016-01-01

    Purpose Our study provides epidemiologic data on the prevalence of refractive errors in all age group ≥5 years in Korea. Methods In 2008 to 2012, a total of 33,355 participants aged ≥5 years underwent ophthalmologic examinations. Using the right eye, myopia was defined as a spherical equivalent (SE) less than -0.5 or -1.0 diopters (D) in subjects aged 19 years and older or as an SE less than -0.75 or -1.25 D in subjects aged 5 to 18 years according to non-cycloplegic refraction. Other refractive errors were defined as follows: high myopia as an SE less than -6.0 D; hyperopia as an SE larger than +0.5 D; and astigmatism as a cylindrical error less than -1.0 D. The prevalence and risk factors of myopia were evaluated. Results Prevalence rates with a 95% confidence interval were determined for myopia (SE <-0.5 D, 51.9% [51.2 to 52.7]; SE <-1.0 D, 39.6% [38.8 to 40.3]), high myopia (5.0% [4.7 to 5.3]), hyperopia (13.4% [12.9 to 13.9]), and astigmatism (31.2% [30.5 to 32.0]). The prevalence of myopia demonstrated a nonlinear distribution with the highest peak between the ages of 19 and 29 years. The prevalence of hyperopia decreased with age in subjects aged 39 years or younger and then increased with age in subjects aged 40 years or older. The prevalence of astigmatism gradually increased with age. Education was associated with all refractive errors; myopia was more prevalent and hyperopia and astigmatism were less prevalent in the highly educated groups. Conclusions In young generations, the prevalence of myopia in Korea was much higher compared to the white or black populations in Western countries and is consistent with the high prevalence found in most other Asian countries. The overall prevalence of hyperopia was much lower compared to that of the white Western population. Age and education level were significant predictive factors associated with all kinds of refractive errors. PMID:27247521

  10. Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculations.

    PubMed

    Karunaratne, Nicholas

    2013-12-01

    To compare the accuracy of the Pentacam Holladay equivalent keratometry readings with the IOL Master 500 keratometry in calculating intraocular lens power. Non-randomized, prospective clinical study conducted in private practice. Forty-five consecutive normal patients undergoing cataract surgery. Forty-five consecutive patients had Pentacam equivalent keratometry readings at the 2-, 3 and 4.5-mm corneal zone and IOL Master keratometry measurements prior to cataract surgery. For each Pentacam equivalent keratometry reading zone and IOL Master measurement the difference between the observed and expected refractive error was calculated using the Holladay 2 and Sanders, Retzlaff and Kraff theoretic (SRKT) formulas. Mean keratometric value and mean absolute refractive error. There was a statistically significantly difference between the mean keratometric values of the IOL Master, Pentacam equivalent keratometry reading 2-, 3- and 4.5-mm measurements (P < 0.0001, analysis of variance). There was no statistically significant difference between the mean absolute refraction error for the IOL Master and equivalent keratometry readings 2 mm, 3 mm and 4.5 mm zones for either the Holladay 2 formula (P = 0.14) or SRKT formula (P = 0.47). The lowest mean absolute refraction error for Holladay 2 equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.17 D). The lowest mean absolute refraction error for SRKT equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.19 D). Comparing the absolute refraction error of IOL Master and Pentacam equivalent keratometry reading, best agreement was with Holladay 2 and equivalent keratometry reading 4.5 mm, with mean of the difference of 0.02 D and 95% limits of agreement of -0.35 and 0.39 D. The IOL Master keratometry and Pentacam equivalent keratometry reading were not equivalent when used only for corneal power measurements. However, the keratometry measurements of the IOL Master and Pentacam equivalent keratometry reading 4.5 mm may be similarly effective when used in intraocular lens power calculation formulas, following constant optimization. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  11. An optomechanical model eye for ophthalmological refractive studies.

    PubMed

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  12. Longitudinal Development of Refractive Error in Children With Accommodative Esotropia: Onset, Amblyopia, and Anisometropia

    PubMed Central

    Wang, Jingyun; Morale, Sarah E.; Ren, Xiaowei; Birch, Eileen E.

    2016-01-01

    Purpose We investigated longitudinal changes of refractive error in children with accommodative esotropia (ET) throughout the first 12 years of life, its dependence on age at onset of ET, and whether amblyopia or anisometropia are associated with defective emmetropization. Methods Longitudinal refractive errors in children with accommodative ET were analyzed retrospectively. Eligibility criteria included: initial hyperopia ≥+4.00 diopters (D), initial cycloplegic refraction before 4 years, at least 3 visits, and at least one visit between 7 and 12 years. Children were classified as having infantile (N = 30; onset ≤12 months) or late-onset (N = 78; onset at 18–48 months) accommodative ET. Cycloplegic refractions culled from medical records were converted into spherical equivalent (SEQ). Results Although the initial visit right eye SEQ was similar for the infantile and late-onset groups (+5.86 ± 1.28 and +5.67 ± 1.26 D, respectively), there were different developmental changes in refractive error. Neither group had a significant decrease in hyperopia before age 7 years, but after 7 years, the infantile group experienced a myopic shift of −0.43 D/y. The late-onset group did not experience a myopic shift at 7 to 12 years. Among amblyopic children, a slower myopic shift was observed for the amblyopic eye. Among anisometropic children, the more hyperopic eye experienced more myopic shift than the less hyperopic eye. Conclusions Children with infantile accommodative ET experienced prolonged hyperopia followed by a myopic shift after 7 years of age, consistent with dissociation between infantile emmetropization and school age myopic shift. In contrast, children with late-onset accommodative ET had little myopic shift before or after 7 years. PMID:27116548

  13. Refractive error and visual impairment in school children in Northern Ireland.

    PubMed

    O'Donoghue, L; McClelland, J F; Logan, N S; Rudnicka, A R; Owen, C G; Saunders, K J

    2010-09-01

    To describe the prevalence of refractive error (myopia and hyperopia) and visual impairment in a representative sample of white school children. The Northern Ireland Childhood Errors of Refraction study, a population-based cross-sectional study, examined 661 white 12-13-year-old and 392 white 6-7-year-old children between 2006 and 2008. Procedures included assessment of monocular logarithm of the minimum angle of resolution (logMAR), visual acuity (unaided and presenting) and binocular open-field cycloplegic (1% cyclopentolate) autorefraction. Myopia was defined as -0.50DS or more myopic spherical equivalent refraction (SER) in either eye, hyperopia as > or =+2.00DS SER in either eye if not previously classified as myopic. Visual impairment was defined as >0.30 logMAR units (equivalent to 6/12). Levels of myopia were 2.8% (95% CI 1.3% to 4.3%) in younger and 17.7% (95% CI 13.2% to 22.2%) in older children: corresponding levels of hyperopia were 26% (95% CI 20% to 33%) and 14.7% (95% CI 9.9% to 19.4%). The prevalence of presenting visual impairment in the better eye was 3.6% in 12-13-year-old children compared with 1.5% in 6-7-year-old children. Almost one in four children fails to bring their spectacles to school. This study is the first to provide robust population-based data on the prevalence of refractive error and visual impairment in Northern Irish school children. Strategies to improve compliance with spectacle wear are required.

  14. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  15. Effects of refractive errors on visual evoked magnetic fields.

    PubMed

    Suzuki, Masaya; Nagae, Mizuki; Nagata, Yuko; Kumagai, Naoya; Inui, Koji; Kakigi, Ryusuke

    2015-11-09

    The latency and amplitude of visual evoked cortical responses are known to be affected by refractive states, suggesting that they may be used as an objective index of refractive errors. In order to establish an easy and reliable method for this purpose, we herein examined the effects of refractive errors on visual evoked magnetic fields (VEFs). Binocular VEFs following the presentation of a simple grating of 0.16 cd/m(2) in the lower visual field were recorded in 12 healthy volunteers and compared among four refractive states: 0D, +1D, +2D, and +4D, by using plus lenses. The low-luminance visual stimulus evoked a main MEG response at approximately 120 ms (M100) that reversed its polarity between the upper and lower visual field stimulations and originated from the occipital midline area. When refractive errors were induced by plus lenses, the latency of M100 increased, while its amplitude decreased with an increase in power of the lens. Differences from the control condition (+0D) were significant for all three lenses examined. The results of dipole analyses showed that evoked fields for the control (+0D) condition were explainable by one dipole in the primary visual cortex (V1), while other sources, presumably in V3 or V6, slightly contributed to shape M100 for the +2D or +4D condition. The present results showed that the latency and amplitude of M100 are both useful indicators for assessing refractive states. The contribution of neural sources other than V1 to M100 was modest under the 0D and +1D conditions. By considering the nature of the activity of M100 including its high sensitivity to a spatial frequency and lower visual field dominance, a simple low-luminance grating stimulus at an optimal spatial frequency in the lower visual field appears appropriate for obtaining data on high S/N ratios and reducing the load on subjects.

  16. Questionnaires for Measuring Refractive Surgery Outcomes.

    PubMed

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  17. Prevalence of vision impairment and refractive error in school children in Ba Ria – Vung Tau province, Vietnam

    PubMed Central

    Paudel, Prakash; Ramson, Prasidh; Naduvilath, Thomas; Wilson, David; Phuong, Ha Thanh; Ho, Suit M; Giap, Nguyen V

    2014-01-01

    Background To assess the prevalence of vision impairment and refractive error in school children 12–15 years of age in Ba Ria – Vung Tau province, Vietnam. Design Prospective, cross-sectional study. Participants 2238 secondary school children. Methods Subjects were selected based on stratified multistage cluster sampling of 13 secondary schools from urban, rural and semi-urban areas. The examination included visual acuity measurements, ocular motility evaluation, cycloplegic autorefraction, and examination of the external eye, anterior segment, media and fundus. Main Outcome Measures Visual acuity and principal cause of vision impairment. Results The prevalence of uncorrected and presenting visual acuity ≤6/12 in the better eye were 19.4% (95% confidence interval, 12.5–26.3) and 12.2% (95% confidence interval, 8.8–15.6), respectively. Refractive error was the cause of vision impairment in 92.7%, amblyopia in 2.2%, cataract in 0.7%, retinal disorders in 0.4%, other causes in 1.5% and unexplained causes in the remaining 2.6%. The prevalence of vision impairment due to myopia in either eye (–0.50 diopter or greater) was 20.4% (95% confidence interval, 12.8–28.0), hyperopia (≥2.00 D) was 0.4% (95% confidence interval, 0.0–0.7) and emmetropia with astigmatism (≥0.75 D) was 0.7% (95% confidence interval, 0.2–1.2). Vision impairment due to myopia was associated with higher school grade and increased time spent reading and working on a computer. Conclusions Uncorrected refractive error, particularly myopia, among secondary school children in Vietnam is a major public health problem. School-based eye health initiative such as refractive error screening is warranted to reduce vision impairment. PMID:24299145

  18. Prevalence of Amblyopia and Refractive Errors Among Primary School Children

    PubMed Central

    Rajavi, Zhale; Sabbaghi, Hamideh; Baghini, Ahmad Shojaei; Yaseri, Mehdi; Moein, Hamidreza; Akbarian, Shadi; Behradfar, Narges; Hosseini, Simin; Rabei, Hossein Mohammad; Sheibani, Kourosh

    2015-01-01

    Purpose: To determine the prevalence of amblyopia and refractive errors among 7 to 12-year-old primary school children in Tehran, Iran. Methods: This population-based cross-sectional study included 2,410 randomly selected students. Visual acuity was tested using an E-chart on Yang vision tester. Refractive errors were measured by photorefractometry and cycloautorefraction. Strabismus was checked using cover test. Direct ophthalmoscopy was used to assess the anterior segment, lens opacities, red reflex and fundus. Functional amblyopia was defined as best corrected visual acuity ≤20/40 in one or both eyes with no anatomical problems. Results: Amblyopia was present in 2.3% (95% CI: 1.8% to 2.9%) of participants with no difference between the genders. Amblyopic subjects were significantly younger than non-amblyopic children (P=0.004). Overall, 15.9% of hyperopic and 5.9% of myopic cases had amblyopia. The prevalence of hyperopia ≥+2.00D, myopia ≤-0.50D, astigmatism ≥0.75D, and anisometropia (≥1.00D) was 3.5%, 4.9%, 22.6%, and 3.9%, respectively. With increasing age, the prevalence of myopia increased (P<0.001), that of hyperopia decreased (P=0.007), but astigmatism showed no change. Strabismus was found in 2.3% of cases. Strabismus (OR=17.9) and refractive errors, especially anisometropia (OR=12.87) and hyperopia (OR=11.87), were important amblyogenic risk factors. Conclusion: The high prevalence of amblyopia in our subjects in comparison to developed countries reveals the necessity of timely and sensitive screening methods. Due to the high prevalence of amblyopia among children with refractive errors, particularly high hyperopia and anisometropia, provision of glasses should be specifically attended by parents and supported by the Ministry of Health and insurance organizations. PMID:27051485

  19. Changes in refractive errors related to spectacle correction of hyperopia.

    PubMed

    Yang, Hee Kyung; Choi, Jung Yeon; Kim, Dae Hyun; Hwang, Jeong-Min

    2014-01-01

    Hyperopic undercorrection is a common clinical practice. However, less is known of its effect on the change in refractive errors and emmetropization throughout the later years of childhood. To evaluate the effect of spectacle correction on the change in refractive errors in hyperopic children less than 12 years of age with or without strabismus. A retrospective cohort study was performed by a computer based search of the hospital database of patients with hyperopia, accommodative esotropia or exotropia. A total of 150 hyperopic children under 12 years of age were included. Patients were classified into four groups: 1) accommodative esotropia with full correction of hyperopia, 2) exotropia with undercorrection of hyperopia, 3) orthotropia with full correction of hyperopia, 4) orthotropia with undercorrection of hyperopia. The 4 groups were matched by initial age on examination and spherical equivalent refractive errors (SER). The main outcome measure was the change in SER (Diopter/year) in both eyes after two years of follow-up. An overall negative shift in SER was noted during the follow-up period in all groups, except for the group with esotropia and full correction. The mean negative shift of hyperopia was more rapid in groups receiving undercorrection of hyperopia with or without strabismus. The amount of undercorrection of hyperopia was positively correlated to the magnitude of decrease in hyperopia in all patients (r = 0.289, P<0.001) and in the subgroup of patients with orthotropia (r = 0.304, P = 0.011). The amount of undercorrection of hyperopia was the only factor associated with a more negative shift in SER (OR, 2.414; 95% CI, 1.202-4.849; P = 0.013). The amount of undercorrection is significantly correlated to the change in hyperopic refractive errors. Full correction of hyperopia may inhibit emmetropization during early and late childhood.

  20. Prevalence of vision impairment and refractive error in school children in Ba Ria - Vung Tau province, Vietnam.

    PubMed

    Paudel, Prakash; Ramson, Prasidh; Naduvilath, Thomas; Wilson, David; Phuong, Ha Thanh; Ho, Suit M; Giap, Nguyen V

    2014-04-01

    To assess the prevalence of vision impairment and refractive error in school children 12-15 years of age in Ba Ria - Vung Tau province, Vietnam. Prospective, cross-sectional study. 2238 secondary school children. Subjects were selected based on stratified multistage cluster sampling of 13 secondary schools from urban, rural and semi-urban areas. The examination included visual acuity measurements, ocular motility evaluation, cycloplegic autorefraction, and examination of the external eye, anterior segment, media and fundus. Visual acuity and principal cause of vision impairment. The prevalence of uncorrected and presenting visual acuity ≤6/12 in the better eye were 19.4% (95% confidence interval, 12.5-26.3) and 12.2% (95% confidence interval, 8.8-15.6), respectively. Refractive error was the cause of vision impairment in 92.7%, amblyopia in 2.2%, cataract in 0.7%, retinal disorders in 0.4%, other causes in 1.5% and unexplained causes in the remaining 2.6%. The prevalence of vision impairment due to myopia in either eye (-0.50 diopter or greater) was 20.4% (95% confidence interval, 12.8-28.0), hyperopia (≥2.00 D) was 0.4% (95% confidence interval, 0.0-0.7) and emmetropia with astigmatism (≥0.75 D) was 0.7% (95% confidence interval, 0.2-1.2). Vision impairment due to myopia was associated with higher school grade and increased time spent reading and working on a computer. Uncorrected refractive error, particularly myopia, among secondary school children in Vietnam is a major public health problem. School-based eye health initiative such as refractive error screening is warranted to reduce vision impairment. © 2013 The Authors. Clinical & Experimental Ophthalmology published by Wiley Publishing Asia Pty Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  1. Education influences the association between genetic variants and refractive error: a meta-analysis of five Singapore studies

    PubMed Central

    Fan, Qiao; Wojciechowski, Robert; Kamran Ikram, M.; Cheng, Ching-Yu; Chen, Peng; Zhou, Xin; Pan, Chen-Wei; Khor, Chiea-Chuen; Tai, E-Shyong; Aung, Tin; Wong, Tien-Yin; Teo, Yik-Ying; Saw, Seang-Mei

    2014-01-01

    Refractive error is a complex ocular trait governed by both genetic and environmental factors and possibly their interplay. Thus far, data on the interaction between genetic variants and environmental risk factors for refractive errors are largely lacking. By using findings from recent genome-wide association studies, we investigated whether the main environmental factor, education, modifies the effect of 40 single nucleotide polymorphisms on refractive error among 8461 adults from five studies including ethnic Chinese, Malay and Indian residents of Singapore. Three genetic loci SHISA6-DNAH9, GJD2 and ZMAT4-SFRP1 exhibited a strong association with myopic refractive error in individuals with higher secondary or university education (SHISA6-DNAH9: rs2969180 A allele, β = −0.33 D, P = 3.6 × 10–6; GJD2: rs524952 A allele, β = −0.31 D, P = 1.68 × 10−5; ZMAT4-SFRP1: rs2137277 A allele, β = −0.47 D, P = 1.68 × 10−4), whereas the association at these loci was non-significant or of borderline significance in those with lower secondary education or below (P for interaction: 3.82 × 10−3–4.78 × 10−4). The evidence for interaction was strengthened when combining the genetic effects of these three loci (P for interaction = 4.40 × 10−8), and significant interactions with education were also observed for axial length and myopia. Our study shows that low level of education may attenuate the effect of risk alleles on myopia. These findings further underline the role of gene–environment interactions in the pathophysiology of myopia. PMID:24014484

  2. Ionospheric Impacts on UHF Space Surveillance

    NASA Astrophysics Data System (ADS)

    Jones, J. C.

    2017-12-01

    Earth's atmosphere contains regions of ionized plasma caused by the interaction of highly energetic solar radiation. This region of ionization is called the ionosphere and varies significantly with altitude, latitude, local solar time, season, and solar cycle. Significant ionization begins at about 100 km (E layer) with a peak in the ionization at about 300 km (F2 layer). Above the F2 layer, the atmosphere is mostly ionized but the ion and electron densities are low due to the unavailability of neutral molecules for ionization so the density decreases exponentially with height to well over 1000 km. The gradients of these variations in the ionosphere play a significant role in radio wave propagation. These gradients induce variations in the index of refraction and cause some radio waves to refract. The amount of refraction depends on the magnitude and direction of the electron density gradient and the frequency of the radio wave. The refraction is significant at HF frequencies (3-30 MHz) with decreasing effects toward the UHF (300-3000 MHz) range. UHF is commonly used for tracking of space objects in low Earth orbit (LEO). While ionospheric refraction is small for UHF frequencies, it can cause errors in range, azimuth angle, and elevation angle estimation by ground-based radars tracking space objects. These errors can cause significant errors in precise orbit determinations. For radio waves transiting the ionosphere, it is important to understand and account for these effects. Using a sophisticated radio wave propagation tool suite and an empirical ionospheric model, we calculate the errors induced by the ionosphere in a simulation of a notional space surveillance radar tracking objects in LEO. These errors are analyzed to determine daily, monthly, annual, and solar cycle trends. Corrections to surveillance radar measurements can be adapted from our simulation capability.

  3. Pharmacology of Myopia and Potential Role for Intrinsic Retinal Circadian Rhythms

    PubMed Central

    Stone, Richard A.; Pardue, Machelle T.; Iuvone, P. Michael; Khurana, Tejvir S.

    2013-01-01

    Despite the high prevalence and public health impact of refractive errors, the mechanisms responsible for ametropias are poorly understood. Much evidence now supports the concept that the retina is central to the mechanism(s) regulating emmetropization and underlying refractive errors. Using a variety of pharmacologic methods and well-defined experimental eye growth models in laboratory animals, many retinal neurotransmitters and neuromodulators have been implicated in this process. Nonetheless, an accepted framework for understanding the molecular and/or cellular pathways that govern postnatal eye development is lacking. Here, we review two extensively studied signaling pathways whose general roles in refractive development are supported by both experimental and clinical data: acetylcholine signaling through muscarinic and/or nicotinic acetylcholine receptors and retinal dopamine pharmacology. The muscarinic acetylcholine receptor antagonist atropine was first studied as an anti-myopia drug some two centuries ago, and much subsequent work has continued to connect muscarinic receptors to eye growth regulation. Recent research implicates a potential role of nicotinic acetycholine receptors; and the refractive effects in population surveys of passive exposure to cigarette smoke, of which nicotine is a constituent, support clinical relevance. Reviewed here, many puzzling results inhibit formulating a mechanistic framework that explains acetylcholine’s role in refractive development. How cholinergic receptor mechanisms might be used to develop acceptable approaches to normalize refractive development remains a challenge. Retinal dopamine signaling not only has a putative role in refractive development, its upregulation by light comprises an important component of the retinal clock network and contributes to the regulation of retinal circadian physiology. During postnatal development, the ocular dimensions undergo circadian and/or diurnal fluctuations in magnitude; these rhythms shift in eyes developing experimental ametropia. Long-standing clinical ideas about myopia in particular have postulated a role for ambient lighting, although molecular or cellular mechanisms for these speculations have remained obscure. Experimental myopia induced by the wearing of a concave spectacle lens alters the retinal expression of a significant proportion of intrinsic circadian clock genes, as well as genes encoding a melatonin receptor and the photopigment melanopsin. Together this evidence suggests a hypothesis that the retinal clock and intrinsic retinal circadian rhythms may be fundamental to the mechanism(s) regulating refractive development, and that disruptions in circadian signals may produce refractive errors. Here we review the potential role of biological rhythms in refractive development. While much future research is needed, this hypothesis could unify many of the disparate clinical and laboratory observations addressing the pathogenesis of refractive errors. PMID:23313151

  4. Refractive lens exchange in younger and older presbyopes: comparison of complication rates, 3 months clinical and patient-reported outcomes

    PubMed Central

    Schallhorn, Steven C; Schallhorn, Julie M; Pelouskova, Martina; Venter, Jan A; Hettinger, Keith A; Hannan, Stephen J; Teenan, David

    2017-01-01

    Purpose To compare refractive and visual outcomes, patient satisfaction, and complication rates among different age categories of patients who underwent refractive lens exchange (RLE). Methods A stratified, simple random sample of patients matched on preoperative sphere and cylinder was selected for four age categories: 45–49 years (group A), 50–54 years (group B), 55–59 years (group C), and 60–65 years (group D). Each group contained 320 patients. All patients underwent RLE with a multifocal intraocular lens at least in one eye. Three months postoperative refractive/visual and patient-reported outcomes are presented. Results The percentage of patients that achieved binocular uncorrected distance visual acuity 20/20 or better was 91.6% (group A), 93.8% (group B), 91.6% (group C), 88.8% (group D), P=0.16. Binocularly, 80.0% of patients in group A, 84.7% in group B, 78.9% in group C, and 77.8% in group D achieved 20/30 or better uncorrected near visual acuity (P=0.13). The proportion of eyes within 0.50 D of emmetropia was 84.4% in group A, 86.8% in group B, 85.7% in group C, and 85.8% in group D (P=0.67). There was no statistically significant difference in postoperative satisfaction, visual phenomena, dry eye symptoms, distance or near vision activities. Apart from higher rate of iritis in the age group 50–55 years, there was no statistically significant difference in postoperative complication rates. Conclusion RLE can be safely performed in younger as well as older presbyopes. No significant difference was found in clinical or patient-reported outcomes. PMID:28894356

  5. Diamond knife-assisted deep anterior lamellar keratoplasty to manage keratoconus.

    PubMed

    Vajpayee, Rasik B; Maharana, Prafulla K; Sharma, Namrata; Agarwal, Tushar; Jhanji, Vishal

    2014-02-01

    To evaluate the outcomes of a new surgical technique, diamond knife-assisted deep anterior lamellar keratoplasty (DALK), and compare its visual and refractive results with big-bubble DALK in cases of keratoconus. Tertiary eyecare hospital. Comparative case series. The visual and surgical outcomes of diamond knife-assisted DALK were compared with those of successful big-bubble DALK. Diamond knife-assisted DALK was performed in 19 eyes and big-bubble DALK, in 11 eyes. All surgeries were completed successfully. No intraoperative or postoperative complications occurred with diamond knife-assisted DALK. Six months after diamond knife-assisted DALK, the mean corrected distance visual acuity (CDVA) improved significantly from 1.87 logMAR ± 0.22 (SD) to 0.23 ± 0.06 logMAR, the mean keratometry improved from 65.99 ± 8.86 diopters (D) to 45.13 ± 1.16 D, and the mean keratometric cylinder improved from 7.99 ± 3.81 D to 2.87 ± 0.59 D (all P=.005). Postoperatively, the mean refractive astigmatism was 2.55 ± 0.49 D and the mean spherical equivalent was -1.97 ± 0.56 D. The mean logMAR CDVA (P = .06), postoperative keratometry (P=.64), refractive cylinder (P=.63), and endothelial cell loss (P=.11) were comparable between diamond knife-assisted DALK and big-bubble DALK. Diamond knife-assisted DALK was effective and predictable as a surgical technique for management of keratoconus cases. This technique has the potential to offer visual and refractive outcomes comparable to those of big-bubble DALK. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Uncorrected amteropia among children hospitalized for headache evaluation: a clinical descriptive study.

    PubMed

    Dotan, Gad; Stolovitch, Chaim; Moisseiev, Elad; Cohen, Shlomi; Kesler, Anat

    2014-09-29

    Headache is a common complaint in children occasionally requiring hospital admission. The purposes of the present study were to analyze the prevalence of uncorrected ametropia in children with headache admitted to the hospital, and evaluate the importance of refraction assessment as part of their evaluation. A retrospective review of children admitted to the Tel Aviv Medical Center for headache evaluation from December 2008 to March 2013, in whom the only abnormality found was an uncorrected refractive error. During the study period 917 children with headache were hospitalized for evaluation and 16 (1.7%) of them (9 boys, mean age 12 years, range 8-18 years) were found to have an uncorrected ametropia. Average headache duration was 4 months (range, 1 week to 1 year) and mean follow-up was 15 months (range, 1 month to 3 years). Twelve (75%) children had brain imaging and 4 children (25%) had a lumbar puncture before their refractive abnormality was identified. Anisometropia and myopia were the most common refractive errors encountered (n = 10 each), followed by hyperopia (n = 6) and astigmatism (n = 3). Despite having uncorrected refractive errors most children (n = 10) did not complain of any visual difficulty. All children were given proper refractive correction and 14 of them reported complete headache resolution on re-examination one month later. Uncorrected ametropia is a possible cause of headache among hospitalized children. Therefore, complete ophthalmic evaluation, which includes proper refraction assessment, is important as it can identify a treatable headache etiology. Children without visual difficulty should be equally evaluated, as many children with headache and uncorrected amteropia do not have vision complaints.

  7. Delayed visual attention caused by high myopic refractive error.

    PubMed

    Winges, Kimberly M; Zarpellon, Ursula; Hou, Chuan; Good, William V

    2005-06-01

    Delayed visual maturation (DVM) is usually a retrospective diagnosis given to infants who are born with no or poor visually-directed behavior, despite normal acuity on objective testing, but who recover months later. This condition can be organized into several types based on associated neurodevelopmental or ocular findings, but the etiology of DVM is probably complex and involves multiple possible origins. Here we report two infants who presented with delayed visual maturation (attention). They were visually unresponsive at birth but were later found to have high myopic errors. Patient 1 had -4 D right eye, -5 D left eye. Patient 2 had -9 D o.u. Upon spectacle correction at 5 and 4 months, respectively, both infants immediately displayed visually-directed behavior, suggesting that a high refractive error was the cause of inattention in these patients. These findings could add to knowledge surrounding DVM and the diagnosis of apparently blind infants. Findings presented here also indicate the importance of prompt refractive error measurement in such cases.

  8. Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free?

    PubMed

    Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil

    2016-04-01

    To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation

    PubMed Central

    Tchah, Hungwon; Nam, Kiyeun; Yoo, Aeri

    2017-01-01

    AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. CONCLUSION A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. PMID:28251083

  10. The Association between Maternal Reproductive Age and Progression of Refractive Error in Urban Students in Beijing

    PubMed Central

    Vasudevan, Balamurali; Jin, Zi Bing; Ciuffreda, Kenneth J.; Jhanji, Vishal; Zhou, Hong Jia; Wang, Ning Li; Liang, Yuan Bo

    2015-01-01

    Purpose To investigate the association between maternal reproductive age and their children’ refractive error progression in Chinese urban students. Methods The Beijing Myopia Progression Study was a three-year cohort investigation. Cycloplegic refraction of these students at both baseline and follow-up vision examinations, as well as non-cycloplegic refraction of their parents at baseline, were performed. Student’s refractive change was defined as the cycloplegic spherical equivalent (SE) of the right eye at the final follow-up minus the cycloplegic SE of the right eye at baseline. Results At the final follow-up, 241 students (62.4%) were reexamined. 226 students (58.5%) with completed refractive data, as well as completed parental reproductive age data, were enrolled. The average paternal and maternal age increased from 29.4 years and 27.5 years in 1993–1994 to 32.6 years and 29.2 years in 2003–2004, respectively. In the multivariate analysis, students who were younger (β = 0.08 diopter/year/year, P<0.001), with more myopic refraction at baseline (β = 0.02 diopter/year/diopter, P = 0.01), and with older maternal reproductive age (β = -0.18 diopter/year/decade, P = 0.01), had more myopic refractive change. After stratifying the parental reproductive age into quartile groups, children with older maternal reproductive age (trend test: P = 0.04) had more myopic refractive change, after adjusting for the children's age, baseline refraction, maternal refraction, and near work time. However, no significant association between myopic refractive change and paternal reproductive age was found. Conclusions In this cohort, children with older maternal reproductive age had more myopic refractive change. This new risk factor for myopia progression may partially explain the faster myopic progression found in the Chinese population in recent decades. PMID:26421841

  11. Gene Profiling in Experimental Models of Eye Growth: Clues to Myopia Pathogenesis

    PubMed Central

    Stone, Richard A.; Khurana, Tejvir S.

    2010-01-01

    To understand the complex regulatory pathways that underlie the development of refractive errors, expression profiling has evaluated gene expression in ocular tissues of well-characterized experimental models that alter postnatal eye growth and induce refractive errors. Derived from a variety of platforms (e.g. differential display, spotted microarrays or Affymetrix GeneChips), gene expression patterns are now being identified in species that include chicken, mouse and primate. Reconciling available results is hindered by varied experimental designs and analytical/statistical features. Continued application of these methods offers promise to provide the much-needed mechanistic framework to develop therapies to normalize refractive development in children. PMID:20363242

  12. Opto-mechanical design of a dispersive artificial eye.

    PubMed

    Coughlan, Mark F; Mihashi, Toshifumi; Goncharov, Alexander V

    2017-05-20

    We present an opto-mechanical artificial eye that can be used for examining multi-wavelength ophthalmic instruments. Standard off-the-shelf lenses and a refractive-index-matching fluid were used in the creation of the artificial eye. In addition to dispersive properties, the artificial eye can be used to simulate refractive error. To analyze the artificial eye, a multi-wavelength Hartmann-Shack aberrometer was used to measure the longitudinal chromatic aberration and the possibility of inducing refractive error. Off-axis chromatic aberrations were also analyzed by imaging through the artificial eye at two discrete wavelengths. Possible extensions to the dispersive artificial eye are also discussed.

  13. Development of a refractive error quality of life scale for Thai adults (the REQ-Thai).

    PubMed

    Sukhawarn, Roongthip; Wiratchai, Nonglak; Tatsanavivat, Pyatat; Pitiyanuwat, Somwung; Kanato, Manop; Srivannaboon, Sabong; Guyatt, Gordon H

    2011-08-01

    To develop a scale for measuring refractive error quality of life (QOL) for Thai adults. The full survey comprised 424 respondents from 5 medical centers in Bangkok and from 3 medical centers in Chiangmai, Songkla and KhonKaen provinces. Participants were emmetropes and persons with refractive correction with visual acuity of 20/30 or better An item reduction process was employed by combining 3 methods-expert opinion, impact method and item-total correlation methods. The classical reliability testing and the validity testing including convergent, discriminative and construct validity was performed. The developed questionnaire comprised 87 items in 6 dimensions: 1) quality of vision, 2) visual function, 3) social function, 4) psychological function, 5) symptoms and 6) refractive correction problems. It is the 5-level Likert scale type. The Cronbach's Alpha coefficients of its dimensions ranged from 0.756 to 0. 979. All validity testing were shown to be valid. The construct validity was validated by the confirmatory factor analysis. A short version questionnaire comprised 48 items with good reliability and validity was also developed. This is the first validated instrument for measuring refractive error quality of life for Thai adults that was developed with strong research methodology and large sample size.

  14. Amblyopia and refractive errors among school-aged children with low socioeconomic status in southeastern Turkey.

    PubMed

    Caca, Ihsan; Cingu, Abdullah Kursat; Sahin, Alparslan; Ari, Seyhmus; Dursun, Mehmet Emin; Dag, Umut; Balsak, Selahattin; Alakus, Fuat; Yavuz, Abdullah; Palanci, Yilmaz

    2013-01-01

    To investigate the prevalence of refractive errors and other eye diseases, incidence and types of amblyopia in school-aged children, and their relation to gender, age, parental education, and socioeconomic factors. A total of 21,062 children 6 to 14 years old were screened. The examination included visual acuity measurements and ocular motility evaluation. Autorefraction under cycloplegia and examination of the external eye, anterior segment, media, and fundus were performed. There were 11,118 females and 9,944 males. The average age was 10.56 ± 3.59 years. When all of the children were evaluated, 3.2% had myopia and 5.9% had hyperopia. Astigmatism 0.50 D or greater was present in 14.3% of children. Myopia was associated with older age, female gender, and higher parental education. Hyperopia was inversely proportional with older age. Spectacles were needed in 4,476 (22.7%) children with refractive errors, and 10.6% of children were unaware of their spectacle needs. Amblyopia was detected in 2.6% of all children. The most common causes of amblyopia were anisometropia (1.2%) and strabismus (0.9%). Visual impairment is a common disorder in school-aged children. Eye health screening programs are beneficial in early detection and proper treatment of refractive errors. Copyright 2013, SLACK Incorporated.

  15. Prevalence of refractive errors in Möbius sequence.

    PubMed

    Cronemberger, Monica Fialho; Polati, Mariza; Debert, Iara; Mendonça, Tomás Scalamandré; Souza-Dias, Carlos; Miller, Marilyn; Ventura, Liana Oliveira; Nakanami, Célia Regina; Goldchmit, Mauro

    2013-01-01

    To assess the prevalence of refractive errors in Möbius sequence. This study was carried out during the Annual Meeting of the Brazilian Möbius Society in November 2008. Forty-four patients diagnosed with the Möbius sequence were submitted to a comprehensive assessment, on the following specialties: ophthalmology, neurology, genetics, psychiatry, psychology and dentistry. Forty-three patients were cooperative and able to undertake the ophthalmological examination. Twenty-two (51.2 %) were male and 21 (48.8%) were female. The average age was 8.3 years (from 2 to 17 years). The visual acuity was evaluated using a retro-illuminated logMAR chart in cooperative patients. All children were submitted to exams on ocular motility, cyclopegic refraction, and fundus examination. From the total of 85 eyes, using the spherical equivalent, the major of the eyes (57.6%) were emmetropics (>-0.50 D and <+2.00 D). The prevalence of astigmatism greater than or equal to 0.75 D was 40%. The prevalence of refractive errors, by the spherical equivalent, was 42.4% in this studied group.

  16. High susceptibility to experimental myopia in a mouse model with a retinal on pathway defect.

    PubMed

    Pardue, Machelle T; Faulkner, Amanda E; Fernandes, Alcides; Yin, Hang; Schaeffel, Frank; Williams, Robert W; Pozdeyev, Nikita; Iuvone, P Michael

    2008-02-01

    Nob mice share the same mutation in the Nyx gene that is found in humans with complete congenital stationary night blindness (CSNB1). Nob mutant mice were studied to determine whether this defect resulted in myopia, as it does in humans. Refractive development was measured in unmanipulated wild-type C57BL/6J (WT) and nob mice from 4 to 12 weeks of age by using an infrared photorefractor. The right eye was form deprived by means of a skull-mounted goggling apparatus at 4 weeks of age. Refractive errors were recorded every 2 weeks after goggling. The content of dopamine and the dopamine metabolite 3,4-dihydroxyphenylacetic acid (DOPAC) were measured by HPLC with electrochemical detection (HPLC-ECD) in retinas of nob and WT mice under light- and dark-adapted conditions. The nob mice had greater hyperopic refractive errors than did the WT mice under normal visual conditions, until 12 weeks of age when both strains had similar refractions. At 6 weeks of age, refractions became less hyperopic in the nob mice but continued to become more hyperopic in the WT mice. After 2 weeks of form deprivation (6 weeks of age), the nob mice displayed a significant myopic shift (~4 D) in refractive error relative to the opposite and control eyes, whereas WT mice required 6 weeks of goggling to elicit a similar response. As expected with loss of ON pathway transmission, light exposure did not alter DOPAC levels in the nob mice. However, dopamine and DOPAC levels were significantly lower in the nob mice compared with WT. Under normal laboratory visual conditions, only minor differences in refractive development were observed between the nob and WT mice. The largest myopic shift in the nob mice resulted after form deprivation, suggesting that visual pathways dependent on nyctalopin and/or abnormally low dopaminergic activity play a role in regulating refractive development. These findings demonstrate an interaction of genetics and environment in refractive development.

  17. High susceptibility to experimental myopia in a mouse model with a retinal ON pathway defect

    PubMed Central

    Pardue, Machelle T.; Faulkner, Amanda E.; Fernandes, Alcides; Yin, Hang; Schaeffel, Frank; Williams, Robert W.; Pozdeyev, Nikita; Iuvone, P. Michael

    2009-01-01

    Purpose Nob mice share the same mutation in the Nyx gene that is found in humans with complete congenital stationary night blindness (CSNB1). We studied nob mutant mice to determine whether this defect resulted in myopia as it does in humans. Methods Refractive development was measured in unmanipulated wildtype C57BL/6J (WT) and nob mice from 4 to 12 weeks of age using an infrared photorefractor. The right eye was form-deprived by means of a skull-mounted goggling apparatus at 4 weeks of age. Refractive errors were recorded every 2 weeks after goggling. The content of dopamine and the dopamine metabolite, DOPAC, were measured using HPLC-ECD in retinas of nob and WT mice under light- and dark-adapted conditions. Results Nob mice had greater hyperopic refractive errors than WT mice under normal visual conditions until 12 weeks of age, when both strains had similar refractions. At 6 weeks of age, refractions became less hyperopic in nob mice but continued to become more hyperopic in WT mice. Following two weeks of form deprivation (6 weeks of age), nob mice displayed a significant myopic shift (~4 D) in refractive error relative to the opposite and control eyes, while WT mice required 6 weeks of goggling to elicit a similar response. As expected with loss of ON pathway transmission, light exposure did not alter DOPAC levels in nob mice. However, dopamine and DOPAC levels were significantly lower in nob mice compared to WT. Conclusions Under normal laboratory visual conditions, only minor differences in refractive development were observed between nob and WT mice. The largest myopic shift in nob mice resulted after form deprivation, suggesting that visual pathways dependent on nyctalopin and/or abnormally low dopaminergic activity play a role in regulating refractive development. These findings demonstrate an interaction of genetics and environment in refractive development. PMID:18235018

  18. Sources of medical error in refractive surgery.

    PubMed

    Moshirfar, Majid; Simpson, Rachel G; Dave, Sonal B; Christiansen, Steven M; Edmonds, Jason N; Culbertson, William W; Pascucci, Stephen E; Sher, Neal A; Cano, David B; Trattler, William B

    2013-05-01

    To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters. Copyright 2013, SLACK Incorporated.

  19. Role of the treating surgeon in the consent process for elective refractive surgery.

    PubMed

    Schallhorn, Steven C; Hannan, Stephen J; Teenan, David; Schallhorn, Julie M

    2016-01-01

    To compare patient's perception of consent quality, clinical and quality-of-life outcomes after laser vision correction (LVC) and refractive lens exchange (RLE) between patients who met their treating surgeon prior to the day of surgery (PDOS) or on the day of surgery (DOS). Retrospective, comparative case series. Optical Express, Glasgow, UK. Patients treated between October 2015 and June 2016 (3972 LVC and 979 RLE patients) who attended 1-day and 1-month postoperative aftercare and answered a questionnaire were included in this study. All patients had a thorough preoperative discussion with an optometrist, watched a video consent, and were provided with written information. Patients then had a verbal discussion with their treating surgeon either PDOS or on the DOS, according to patient preference. Preoperative and 1-month postoperative visual acuity, refraction, preoperative, 1-day and 1-month postoperative questionnaire were compared between DOS and PDOS patients. Multivariate regression model was developed to find factors associated with patient's perception of consent quality. Preoperatively, 8.0% of LVC and 17.1% of RLE patients elected to meet their surgeon ahead of the surgery day. In the LVC group, 97.5% of DOS and 97.2% of PDOS patients indicated they were properly consented for surgery ( P =0.77). In the RLE group, 97.0% of DOS and 97.0% of PDOS patients stated their consent process for surgery was adequate ( P =0.98). There was no statistically significant difference between DOS and PDOS patients in most of the postoperative clinical or questionnaire outcomes. Factors predictive of patient's satisfaction with consent quality were postoperative satisfaction with vision (46.7% of explained variance), difficulties with night driving, close-up vision or outdoor/sports activities (25.4%), visual phenomena (12.2%), dry eyes (7.5%), and patient's satisfaction with surgeon's care (8.2%). Perception of quality of consent was comparable between patients that elected to meet the surgeon PDOS, and those who did not.

  20. Comparison of femtosecond laser-assisted descemetic and predescemetic lamellar keratoplasty for keratoconus.

    PubMed

    Lu, Yan; Grisolia, Ana Beatriz Diniz; Ge, Yi-Rui; Xue, Chun-Yan; Cao, Qian; Yang, Li-Ping; Huang, Zhen-Ping

    2017-01-01

    The purpose of this study is to compare the outcomes following femtosecond laser-assisted deep anterior lamellar keratoplasty (DALK) with 75% of stromal dissection (predescemetic group) and femtosecond laser-assisted DALK using big-bubble technique with total stromal resection (descemetic group) for the treatment of keratoconus. Twenty eyes of 17 patients with keratoconus were studied. There were 10 eyes of 9 patients in predescemetic group and 10 eyes of 8 patients in descemetic group. The postoperative best-corrected visual acuity (BCVA), manifest refraction, keratometry, endothelial cell density (ECD), and central corneal thickness (CCT) were analyzed. All surgeries were performed uneventfully. At 1 year after surgery, the BCVA, corneal astigmatism, keratometry, CCT, and ECD between two groups were not statistically significant (all P > 0.05). However, the mean manifest refraction was -9.43 ± 7.44 diopter (D) and -1.03 ± 1.13D in predescemetic and descemetic groups, respectively, which was statistically significant between two groups (P < 0.05). The results of BCVA and corneal astigmatism, keratometry, ECD, and CCT were comparable between two groups. However, the mean postoperative manifest refraction was lower in descemetic group.

Top