DOE Office of Scientific and Technical Information (OSTI.GOV)
Rebollo, L.
1992-04-01
Several beyond-design bases cold leg small-break LOCA postulated scenarios based on the lessons learned'' in the OECD-LOFT LP-SB-3 experiment have been analyzed for the Westinghouse single loop Jose Cabrera Nuclear Power Plant belonging to the Spanish utility UNION ELECTRICA FENOSA, S.A. The analysis has been done by the utility in the Thermal-Hydraulic Accident Analysis Section of the Engineering Department of the Nuclear Division. The RELAP5/MOD2/36.04 code has been used on a CYBER 180/830 computer and the simulation includes the 6 in. RHRS charging line, the 2 in. pressurizer spray, and the 1.5 in. CVCS make-up line piping breaks. The assumptionmore » of a total black-out condition'' coincident with the occurrence of the event has been made in order to consider a plant degraded condition with total active failure of the ECCS. As a result of the analysis, estimates of the time to core overheating startup'' as well as an evaluation of alternate operator measures to mitigate the consequences of the event have been obtained. Finally a proposal for improving the LOCA emergency operating procedure (E-1) has been suggested.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rebollo, L.
1992-04-01
Several beyond-design bases cold leg small-break LOCA postulated scenarios based on the ``lessons learned`` in the OECD-LOFT LP-SB-3 experiment have been analyzed for the Westinghouse single loop Jose Cabrera Nuclear Power Plant belonging to the Spanish utility UNION ELECTRICA FENOSA, S.A. The analysis has been done by the utility in the Thermal-Hydraulic & Accident Analysis Section of the Engineering Department of the Nuclear Division. The RELAP5/MOD2/36.04 code has been used on a CYBER 180/830 computer and the simulation includes the 6 in. RHRS charging line, the 2 in. pressurizer spray, and the 1.5 in. CVCS make-up line piping breaks. Themore » assumption of a ``total black-out condition`` coincident with the occurrence of the event has been made in order to consider a plant degraded condition with total active failure of the ECCS. As a result of the analysis, estimates of the ``time to core overheating startup`` as well as an evaluation of alternate operator measures to mitigate the consequences of the event have been obtained. Finally a proposal for improving the LOCA emergency operating procedure (E-1) has been suggested.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbiener, W.A.; Cudnik, R.A.; Dykhuizen, R.C.
Experimental studies were conducted in a /sup 2///sub 15/-scale model of a four-loop pressurized water reactor at pressures to 75 psia to extend the understanding of steam-water interaction phenomena and processes associated with a loss-of-coolant accident. Plenum filling studies were conducted with hydraulic communication between the cold leg and core steam supplies and hot walls, with both fixed and ramped steam flows. Comparisons of correlational fits have been made for penetration data obtained with hydraulic communication, fixed cold leg steam, and no cold leg steam. Statistical tests applied to these correlational fits have indicated that the hydraulic communication and fixedmore » cold leg steam data can be considered to be a common data set. Comparing either of these data sets to the no cold leg steam data using the statistical test indicated that it was unlikely that these sets could be considered to be a common data set. The introduction of cold leg steam results in a slight decrease in penetration relative to that obtained without cold leg steam at the same value of subcooling of water entering the downcomer. A dimensionless parameter which is a weighted mean of a modified Froude number and the Weber number has been proposed as a scaling parameter for penetration data. This parameter contains an additional degree of freedom which allows data from different scales to collapse more closely to a single curve than current scaling parameters permit.« less
NASA Astrophysics Data System (ADS)
Takeda, Takeshi; Maruyama, Yu; Watanabe, Tadashi; Nakamura, Hideo
Experiments simulating PWR intermediate-break loss-of-coolant accidents (IBLOCAs) with 17% break at hot leg or cold leg were conducted in OECD/NEA ROSA-2 Project using the Large Scale Test Facility (LSTF). In the hot leg IBLOCA test, core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing (LSC) induced by steam condensation on accumulator coolant injected into cold leg. Water remained on upper core plate in upper plenum due to counter-current flow limiting (CCFL) because of significant upward steam flow from the core. In the cold leg IBLOCA test, core dryout took place due to rapid liquid level drop in the core before LSC. Liquid was accumulated in upper plenum, steam generator (SG) U-tube upflow-side and SG inlet plenum before the LSC due to CCFL by high velocity vapor flow, causing enhanced decrease in the core liquid level. The RELAP5/MOD3.2.1.2 post-test analyses of the two LSTF experiments were performed employing critical flow model in the code with a discharge coefficient of 1.0. In the hot leg IBLOCA case, cladding surface temperature of simulated fuel rods was underpredicted due to overprediction of core liquid level after the core uncovery. In the cold leg IBLOCA case, the cladding surface temperature was underpredicted too due to later core uncovery than in the experiment. These may suggest that the code has remaining problems in proper prediction of primary coolant distribution.
LMFBR with booster pump in pumping loop
Rubinstein, H.J.
1975-10-14
A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.
Locating hot and cold-legs in a nuclear powered steam generation system
Ekeroth, D.E.; Corletti, M.M.
1993-11-16
A nuclear reactor steam generator includes a reactor vessel for heating water and a steam generator with a pump casing at the lowest point on the steam generator. A cold-leg pipe extends horizontally between the steam generator and the reactor vessel to return water from the steam generator to the reactor vessel. The bottom of the cold-leg pipe is at a first height above the bottom of the reactor vessel. A hot-leg pipe with one end connected to the steam generator and a second end connected to the reactor vessel has a first pipe region extending downwardly from the steam generator to a location between the steam generator and the reactor vessel at which a bottom of the hot-leg pipe is at a second height above the bottom of the reactor vessel. A second region extends from that location in a horizontal direction at the second height to the point at which the hot-leg pipe connects to the reactor vessel. A pump is attached to the casing at a location below the first and second heights and returns water from the steam generator to the reactor vessel over the cold-leg. The first height is greater than the second height and the bottom of the steam generator is at a height above the bottom of the reactor vessel that is greater than the first and second heights. A residual heat recovery pump is below the hot-leg and has an inlet line from the hot-leg that slopes down continuously to the pump inlet. 2 figures.
Locating hot and cold-legs in a nuclear powered steam generation system
Ekeroth, Douglas E.; Corletti, Michael M.
1993-01-01
A nuclear reactor steam generator includes a reactor vessel for heating water and a steam generator with a pump casing at the lowest point on the steam generator. A cold-leg pipe extends horizontally between the steam generator and the reactor vessel to return water from the steam generator to the reactor vessel. The bottom of the cold-leg pipe is at a first height above the bottom of the reactor vessel. A hot-leg pipe with one end connected to the steam generator and a second end connected to the reactor vessel has a first pipe region extending downwardly from the steam generator to a location between the steam generator and the reactor vessel at which a bottom of the hot-leg pipe is at a second height above the bottom of the reactor vessel. A second region extends from that location in a horizontal direction at the second height to the point at which the hot-leg pipe connects to the reactor vessel. A pump is attached to the casing at a location below the first and second heights and returns water from the steam generator to the reactor vessel over the cold-leg. The first height is greater than the second height and the bottom of the steam generator is at a height above the bottom of the reactor vessel that is greater than the first and second heights. A residual heat recovery pump is below the hot-leg and has an inlet line from the hot-leg that slopes down continuously to the pump inlet.
NASA Technical Reports Server (NTRS)
Jacob, G.; Costa, F.; Shannon, J.; Robertson, D.; Biaggioni, I.
2000-01-01
Sympathetic activation produced by various stimuli, eg, mental stress or handgrip, evokes regional vascular responses that are often nonhomogeneous. This phenomenon is believed to be the consequence of the recruitment of differential central neural pathways or of a sympathetically mediated vasodilation. The purpose of this study was to determine whether a similar heterogeneous response occurs with cold pressor stimulation and to test the hypothesis that local differences in adrenergic receptor function could be in part responsible for this diversity. In 8 healthy subjects, local norepinephrine spillover and blood flow were measured in arms and legs at baseline and during sympathetic stimulation induced by baroreflex mechanisms (nitroprusside infusion) or cold pressor stimulation. At baseline, legs had higher vascular resistance (27+/-5 versus 17+/-2 U, P=0.05) despite lower norepinephrine spillover (0.28+/-0.04 versus 0.4+/-0.05 mg. min(-1). dL(-1), P=0.03). Norepinephrine spillover increased similarly in both arms and legs during nitroprusside infusion and cold pressor stimulation. On the other hand, during cold stimulation, vascular resistance increased in arms but not in legs (20+/-9% versus -7+/-4%, P=0.03). Increasing doses of isoproterenol and phenylephrine were infused intra-arterially in arms and legs to estimate beta-mediated vasodilation and alpha-induced vasoconstriction, respectively. beta-Mediated vasodilation was significantly lower in legs compared with arms. Thus, we report a dissociation between norepinephrine spillover and vascular responses to cold stress in lower limbs characterized by a paradoxical decrease in local resistance despite increases in sympathetic activity. The differences observed in adrenergic receptor responses cannot explain this phenomenon.
Test prediction for the German PKL Test K5A using RELAP4/MOD6
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Y.S.; Haigh, W.S.; Sullivan, L.H.
RELAP4/MOD6 is the most recent modification in the series of RELAP4 computer programs developed to describe the thermal-hydraulic conditions attendant to postulated transients in light water reactor systems. The major new features in RELAP4/MOD6 include best-estimate pressurized water reactor (PWR) reflood transient analytical models for core heat transfer, local entrainment, and core vapor superheat, and a new set of heat transfer correlations for PWR blowdown and reflood. These new features were used for a test prediction of the Kraftwerk Union three-loop PRIMAR KREISLAUF (PKL) Reflood Test K5A. The results of the prediction were in good agreement with the experimental thermalmore » and hydraulic system data. Comparisons include heater rod surface temperature, system pressure, mass flow rates, and core mixture level. It is concluded that RELAP4/MOD6 is capable of accurately predicting transient reflood phenomena in the 200% cold-leg break test configuration of the PKL reflood facility.« less
Measurement and simulation of thermoelectric efficiency for single leg
NASA Astrophysics Data System (ADS)
Hu, Xiaokai; Yamamoto, Atsushi; Ohta, Michihiro; Nishiate, Hirotaka
2015-04-01
Thermoelectric efficiency measurements were carried out on n-type bismuth telluride legs with the hot-side temperature at 100 and 150 °C. The electric power and heat flow were measured individually. Water coolant was utilized to maintain the cold-side temperature and to measure heat flow out of the cold side. Leg length and vacuum pressure were studied in terms of temperature difference across the leg, open-circuit voltage, internal resistance, and heat flow. Finite-element simulation on thermoelectric generation was performed in COMSOL Multiphysics, by inputting two-side temperatures and thermoelectric material properties. The open-circuit voltage and resistance were in good agreement between the measurement and simulation. Much larger heat flows were found in measurements, since they were comprised of conductive, convective, and radiative contributions. Parasitic heat flow was measured in the absence of bismuth telluride leg, and the conductive heat flow was then available. Finally, the maximum thermoelectric efficiency was derived in accordance with the electric power and the conductive heat flow.
Hayter, Kane J.; Schumann, Moritz; Deakin, Glen B.
2016-01-01
This study examined the effects of cold-water immersion (CWI) and cold air therapy (CAT) on maximal cycling performance (i.e. anaerobic power) and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10) and female (n = 10) participants were randomised into either: CWI (15 min in 14 °C water to iliac crest) or CAT (15 min in 14 °C air) immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively). Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24), 48 (T48) and 72 (T72) h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05). However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90), T48 (8% ± 2%, ES = 0.64) and T72 (8% ± 7%, ES = 0.76). The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone. PMID:27069791
Thermoelectric materials evaluation program. Technical summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinderman, J.D.
1979-04-01
Research progress on the thermoelectric materials evaluation program is reported covering the period January 1, 1976 to September 30, 1978. Topical reports are presented on (1) hot and cold end ..delta..T's, (2) hardware mobility, (3) p-leg sublimation suppression, (4) thermodynamic stability of p-legs, (5) n-leg material process improvements to reduce extraneous resistance, (6) n-leg cracking, (7) dynamic evaluation of converter, and (8) data base and degradation modes. Twenty attachments are included which present supporting drawings, specifications, procedures, and data. (WHK)
Human thermal responses during leg-only exercise in cold water.
Golden, F S; Tipton, M J
1987-10-01
1. Exercise during immersion in cold water has been reported by several authors to accelerate the rate of fall of core temperature when compared with rates seen during static immersion. The nature of the exercise performed, however, has always been whole-body in nature. 2. In the present investigation fifteen subjects performed leg exercise throughout a 40 min head-out immersion in water at 15 degrees C. The responses obtained were compared with those seen when the subjects performed an identical static immersion. 3. Aural and rectal temperatures were found to fall by greater amounts during static immersion. 4. It is concluded that 'the type of exercise performed' should be included in the list of factors which affect core temperature during cold water immersion.
Corrosion of Type 316L stainless steel in Pb-17Li
NASA Astrophysics Data System (ADS)
Barker, M. G.; Lees, J. A.; Sample, T.; Hubberstey, P.
1991-03-01
Corrosion tests carried out in Pb-17Li in both capsules and a convection loop (hot leg temperature 768 K, cold leg temperature 748 K, flow rate 10 mm/s) have shown that Type 316 stainless steel undergoes almost complete loss of Ni and Mn, and extensive loss of Cr to form a porous ferritic zone. Ferritic zone depths measured on the loop samples exposed between 1000 and 4000 h were in good agreement with previous data. Some evidence was found for the interaction of chromium with oxygen dissolved in Pb-17Li. Examination of the cold leg samples revealed deposition products of iron and chromium but no deposits containing nickels were observed. These observations were rationalised in terms of recent measurements of the solubilities of metals in Pb-17Li.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eyler, L.L.; Trent, D.S.
The TEMPEST computer program was used to simulate fluid and thermal mixing in the cold leg and downcomer of a pressurized water reactor under emergency core cooling high-pressure injection (HPI), which is of concern to the pressurized thermal shock (PTS) problem. Application of the code was made in performing an analysis simulation of a full-scale Westinghouse three-loop plant design cold leg and downcomer. Verification/assessment of the code was performed and analysis procedures developed using data from Creare 1/5-scale experimental tests. Results of three simulations are presented. The first is a no-loop-flow case with high-velocity, low-negative-buoyancy HPI in a 1/5-scale modelmore » of a cold leg and downcomer. The second is a no-loop-flow case with low-velocity, high-negative density (modeled with salt water) injection in a 1/5-scale model. Comparison of TEMPEST code predictions with experimental data for these two cases show good agreement. The third simulation is a three-dimensional model of one loop of a full size Westinghouse three-loop plant design. Included in this latter simulation are loop components extending from the steam generator to the reactor vessel and a one-third sector of the vessel downcomer and lower plenum. No data were available for this case. For the Westinghouse plant simulation, thermally coupled conduction heat transfer in structural materials is included. The cold leg pipe and fluid mixing volumes of the primary pump, the stillwell, and the riser to the steam generator are included in the model. In the reactor vessel, the thermal shield, pressure vessel cladding, and pressure vessel wall are thermally coupled to the fluid and thermal mixing in the downcomer. The inlet plenum mixing volume is included in the model. A 10-min (real time) transient beginning at the initiation of HPI is computed to determine temperatures at the beltline of the pressure vessel wall.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ezsoel, G.; Guba, A.; Perneczky, L.
Results of a small-break loss-of-coolant accident experiment, conducted on the PMK-2 integral-type test facility are presented. The experiment simulated a 1% break in the cold leg of a VVER-440-type reactor. The main phenomena of the experiment are discussed, and in the case of selected events, a more detailed interpretation with the help of measured void fraction, obtained by a special measurement device, is given. Two thermohydraulic computer codes, RELAP5 and ATHLET, are used for posttest calculations. The aim of these calculations is to investigate the code capability for modeling natural circulation phenomena in VVER-440-type reactors. Therefore, the results of themore » experiment and both calculations are compared. Both codes predict most of the transient events well, with the exception that RELAP5 fails to predict the dryout period in the core. In the experiment, the hot- and cold-leg loop-seal clearing is accompanied by natural circulation instabilities, which can be explained by means of the ATHLET calculation.« less
Zotter, Heinz; Kerbl, Reinhold; Gallistl, Siegfried; Nitsche, Hilde; Borkenstein, Martin
2003-12-01
The aim of this study was to determine whether infrared thermography before and after challenge of the lower leg in cold water may be a useful tool to detect abnormalities in skin blood flow in adolescent asymptomatic patients with type 1 diabetes mellitus (DM1) and to assess the optimal setting of skin temperature measurements. Twenty-five adolescents (10 female, 15 male, mean age 21.2 +/- 6.2 years, body mass index [BMI] 23.0 +/- 2.1 kg/m2) with a duration of DMI of 13.8 +/- 5.4 years and mean HbA1c levels 8.5 +/- 1.3% were compared to age- and sex-matched controls (BMI 22.9 +/- 2.2 kg/m2). Seven defined sites of the lower leg were assessed by infrared thermography before and for 10 min after exposure of the leg to 14 degrees C cold water. As skin temperature before exposure to cold water differs from individual to individual and basal temperature was significantly warmer in patients at the tip of the first (p < 0.05) and fifth (p < 0.05) toe, the rewarming index was calculated in order to compare data. Rewarming indexes of skin temperature during the whole measurement procedure (0-10 min) were significantly lower at the tip of the first (p < 0.05) and fifth (p < 0.01) toes and from minute 2-10 also at the inner ankle (p < 0.05) in patients compared to healthy controls. Rewarming indexes of the other four sites were not significantly different between patients and controls. Infrared thermography of the lower leg after cold water exposure is an easily applicable method and a useful tool to detect abnormalities of skin blood flow in adolescents with DM1 especially at the tips of the first and fifth toes and the inner ankle.
Estimation of regional cutaneous cold sensitivity by analysis of the gasping response.
Burke, W E; Mekjavić, I B
1991-11-01
Regional cutaneous sensitivity to cooling was assessed in males by separately immersing four discrete skin regions in cold water (15 degrees C) during head-out immersion. The response measured was gasping at the onset of immersion; the gasping response appears to be the result of a nonthermoregulatory neurogenic drive from cutaneous cold receptors. Subjects of similar body proportions wore a neoprene "dry" suit modified to allow exposure to the water of either the arms, upper torso, lower torso, or legs, while keeping the unexposed skin regions thermoneutral. Each subject was immersed to the sternal notch in all four conditions of partial exposure plus one condition of whole body exposure. The five cold water conditions were matched by control immersions in lukewarm (34 degrees C) water, and trials were randomized. The magnitude of the gasping response was determined by mouth occlusion pressure (P0.1). For each subject, P0.1 values for the 1st min of immersion were integrated, and control trial values, although minimal, were subtracted from their cold water counterpart to account for any gasping due to the experimental design. Results were averaged and showed that the highest P0.1 values were elicited from whole body exposure, followed in descending order by exposures of the upper torso, legs, lower torso, and arms. Correction of the P0.1 response for differences in exposed surface area (A) and cooling stimulus (delta T) between regions gave a cold sensitivity index [CSI, P0.1/(A.delta T)] for each region and showed that the index for the upper torso was significantly higher than that for the arms or legs; no significant difference was observed between the indexes for the upper and lower torso.(ABSTRACT TRUNCATED AT 250 WORDS)
Reflux cooling experiments on the NCSU scaled PWR facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doster, J.M.; Giavedoni, E.
1993-01-01
Under loss of forced circulation, coupled with the loss or reduction in primary side coolant inventory, horizontal stratified flows can develop in the hot and cold legs of pressurized water reactors (PWRs). Vapor produced in the reactor vessel is transported through the hot leg to the steam generator tubes where it condenses and flows back to the reactor vessel. Within the steam generator tubes, the flow regimes may range from countercurrent annular flow to single-phase convection. As a result, a number of heat transfer mechanisms are possible, depending on the loop configuration, total heat transfer rate, and the steam flowmore » rate within the tubes. These include (but are not limited to) two-phase natural circulation, where the condensate flows concurrent to the vapor stream and is transported to the cold leg so that the entire reactor coolant loop is active, and reflux cooling, where the condensate flows back down the interior of the coolant tubes countercurrent to the vapor stream and is returned to the reactor vessel through the hot leg. While operating in the reflux cooling mode, the cold leg can effectively be inactive. Heat transfer can be further influenced by noncondensables in the vapor stream, which accumulate within the upper regions of the steam generator tube bundle. In addition to reducing the steam generator's effective heat transfer area, under these conditions operation under natural circulation may not be possible, and reflux cooling may be the only viable heat transfer mechanism. The scaled PWR (SPWR) facility in the nuclear engineering department at North Carolina State Univ. (NCSU) is being used to study the effectiveness of two-phase natural circulation and reflux cooling under conditions associated with loss of forced circulation, midloop coolant levels, and noncondensables in the primary coolant system.« less
Thermal, cardiac and adrenergic responses to repeated local cooling.
Janský, L; Matousková, E; Vávra, V; Vybíral, S; Janský, P; Jandová, D; Knízková, I; Kunc, P
2006-01-01
The aim of this study was to ascertain whether repeated local cooling induces the same or different adaptational responses as repeated whole body cooling. Repeated cooling of the legs (immersion into 12 degrees C water up to the knees for 30 min, 20 times during 4 weeks = local cold adaptation - LCA) attenuated the initial increase in heart rate and blood pressure currently observed in control subjects immersed in cold water up to the knees. After LCA the initial skin temperature decrease tended to be lower, indicating reduced vasoconstriction. Heart rate and systolic blood pressure appeared to be generally lower during rest and during the time course of cooling in LCA humans, when compared to controls. All these changes seem to indicate attenuation of the sympathetic tone. In contrast, the sustained skin temperature in different areas of the body (finger, palm, forearm, thigh, chest) appeared to be generally lower in LCA subjects than in controls (except for temperatures on the forehead). Plasma levels of catecholamines (measured 20 and 40 min after the onset of cooling) were also not influenced by local cold adaptation. Locally cold adapted subjects, when exposed to whole body cold water immersion test, showed no change in the threshold temperature for induction of cold thermogenesis. This indicates that the hypothermic type of cold adaptation, typically occurring after systemic cold adaptation, does not appear after local cold adaptation of the intensity used. It is concluded that in humans the cold adaptation due to repeated local cooling of legs induces different physiological changes than systemic cold adaptation.
Clara Wheeler; James Bettaso; Donald Ashton; Hartwell Welsh
2013-01-01
The cold temperatures maintained in the Trinity River are beneficial to fish but may be problematic for foothill yellow-legged frogs. We examined the timing of breeding, reproductive output, and growth and development of tadpoles for populations of foothill yellow-legged frogs on the mainstem and six tributaries of the Trinity River. On the colder mainstem, onset of...
Barwood, Martin J; Burrows, Holly; Cessford, Jess; Goodall, Stuart
2016-02-01
Accidental cold-water immersion (CWI) evokes the life threatening cold shock response (CSR) which increases the risk of drowning. Consequently, the safety behaviour selected is critical in determining survival; the present advice is to 'float first' and remain stationary (i.e. rest). We examined whether leg only exercise (i.e., treading water; 'CWI-Kick') immediately on CWI could reduce the symptoms of the CSR, offset the reduction in cerebral blood flow that is known to occur and reduce the CSR's symptoms of breathlessness. We also examined whether perceptual responses instinctive to accidental CWI were exacerbated by this alternative behaviour. We contrasted CWI-Kick to a 'CWI-Rest' condition and a thermoneutral control (35°C); 'TN-Rest'. Seventeen participants were tested (9 males, 8 females). All immersions were standardised; water temperature in cold conditions (i.e., 12°C) was matched ±/0.5°C within participant. Middle cerebral artery blood flow velocity (MCAv) and cardiorespiratory responses were measured along with thermal perception (sensation and comfort) and dyspnoea. Data were analysed using repeated measures ANOVA (alpha level of 0.05). MCAv was significantly reduced in CWI-Rest (-6 (9)%; 1st minute of immersion) but was offset by leg only exercise immediately on cold water entry; CWI-Kick MCAv was never different to TN-Rest (-3 (16)% cf. 5 (4)%). All CWI cardiorespiratory and perceptual responses were different to TN-Rest but were not exacerbated by leg only exercise. Treading water may aid survival by offsetting the reduction in brain blood flow velocity without changing the instinctive behavioural response (i.e. perceptions). "Float first - and kick for your life" would be a suitable amendment to the water safety advice. Copyright © 2015 Elsevier Inc. All rights reserved.
Analysis of unmitigated large break loss of coolant accidents using MELCOR code
NASA Astrophysics Data System (ADS)
Pescarini, M.; Mascari, F.; Mostacci, D.; De Rosa, F.; Lombardo, C.; Giannetti, F.
2017-11-01
In the framework of severe accident research activity developed by ENEA, a MELCOR nodalization of a generic Pressurized Water Reactor of 900 MWe has been developed. The aim of this paper is to present the analysis of MELCOR code calculations concerning two independent unmitigated large break loss of coolant accident transients, occurring in the cited type of reactor. In particular, the analysis and comparison between the transients initiated by an unmitigated double-ended cold leg rupture and an unmitigated double-ended hot leg rupture in the loop 1 of the primary cooling system is presented herein. This activity has been performed focusing specifically on the in-vessel phenomenology that characterizes this kind of accidents. The analysis of the thermal-hydraulic transient phenomena and the core degradation phenomena is therefore here presented. The analysis of the calculated data shows the capability of the code to reproduce the phenomena typical of these transients and permits their phenomenological study. A first sequence of main events is here presented and shows that the cold leg break transient results faster than the hot leg break transient because of the position of the break. Further analyses are in progress to quantitatively assess the results of the code nodalization for accident management strategy definition and fission product source term evaluation.
Recovery From Exercise-Induced Muscle Damage: Cold-Water Immersion Versus Whole-Body Cryotherapy.
Abaïdia, Abd-Elbasset; Lamblin, Julien; Delecroix, Barthélémy; Leduc, Cédric; McCall, Alan; Nédélec, Mathieu; Dawson, Brian; Baquet, Georges; Dupont, Grégory
2017-03-01
To compare the effects of cold-water immersion (CWI) and whole-body cryotherapy (WBC) on recovery kinetics after exercise-induced muscle damage. Ten physically active men performed single-leg hamstring eccentric exercise comprising 5 sets of 15 repetitions. Immediately postexercise, subjects were exposed in a randomized crossover design to CWI (10 min at 10°C) or WBC (3 min at -110°C) recovery. Creatine kinase concentrations, knee-flexor eccentric (60°/s) and posterior lower-limb isometric (60°) strength, single-leg and 2-leg countermovement jumps, muscle soreness, and perception of recovery were measured. The tests were performed before and immediately, 24, 48, and 72 h after exercise. Results showed a very likely moderate effect in favor of CWI for single-leg (effect size [ES] = 0.63; 90% confidence interval [CI] = -0.13 to 1.38) and 2-leg countermovement jump (ES = 0.68; 90% CI = -0.08 to 1.43) 72 h after exercise. Soreness was moderately lower 48 h after exercise after CWI (ES = -0.68; 90% CI = -1.44 to 0.07). Perception of recovery was moderately enhanced 24 h after exercise for CWI (ES = -0.62; 90% CI = -1.38 to 0.13). Trivial and small effects of condition were found for the other outcomes. CWI was more effective than WBC in accelerating recovery kinetics for countermovement-jump performance at 72 h postexercise. CWI also demonstrated lower soreness and higher perceived recovery levels across 24-48 h postexercise.
How adaptive optics may have won the Cold War
NASA Astrophysics Data System (ADS)
Tyson, Robert K.
2013-05-01
While there are many theories and studies concerning the end of the Cold War, circa 1990, I postulate that one of the contributors to the result was the development of adaptive optics. The emergence of directed energy weapons, specifically space-based and ground-based high energy lasers made practicable with adaptive optics, showed that a successful defense against inter-continental ballistic missiles was not only possible, but achievable in a reasonable period of time.
... Long-term Abdominal Pain (Stomach Pain), Short-term Ankle Problems Breast Problems in Men Breast Problems in Women Chest Pain in Infants and Children Chest Pain, Acute Chest Pain, Chronic Cold and Flu Cough Diarrhea ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sy, W.M.; Westring, D.W.; Weinberger, G.
1975-11-01
Photon-deficient foci or cold lesions were demonstrated on /sup 99m/Tc- polyphosphate bone imaging in eight individuals with various malignancies and one in sickle cell crisis. The bone radiographs of five of these persons failed to show corresponding bony changes at the time of the imaging. Most of the cold lesions observed on bone imaging were located in the denser and tubular bones. A postulate has been advanced regarding the factors that might influence the different gamma-imaging manifestations of radiographically demonstrable lytic lesions. The cases presented herein further emphasize the importance of recognizing the existence of cold areas in the imagesmore » of bones and the need to place these in proper perspective when interpreting scans. (auth)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Subhasish; Soppet, William K.; Majumdar, Saurindranath
This paper discusses a system-level finite element model of a two-loop pressurized water reactor (PWR). Based on this model, system-level heat transfer analysis and subsequent sequentially coupled thermal-mechanical stress analysis were performed for typical thermal-mechanical fatigue cycles. The in-air fatigue lives of example components, such as the hot and cold legs, were estimated on the basis of stress analysis results, ASME in-air fatigue life estimation criteria, and fatigue design curves. Furthermore, environmental correction factors and associated PWR environment fatigue lives for the hot and cold legs were estimated by using estimated stress and strain histories and the approach described inmore » US-NRC report: NUREG-6909.« less
Thermal margin protection system for a nuclear reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musick, C.R.
1974-02-12
A thermal margin protection system for a nuclear reactor is described where the coolant flow flow trip point and the calculated thermal margin trip point are switched simultaneously and the thermal limit locus is made more restrictive as the allowable flow rate is decreased. The invention is characterized by calculation of the thermal limit Locus in response to applied signals which accurately represent reactor cold leg temperature and core power; cold leg temperature being corrected for stratification before being utilized and reactor power signals commensurate with power as a function of measured neutron flux and thermal energy added to themore » coolant being auctioneered to select the more conservative measure of power. The invention further comprises the compensation of the selected core power signal for the effects of core radial peaking factor under maximum coolant flow conditions. (Official Oazette)« less
Bed inventory overturn in a circulating fluid bed riser with pant-leg structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jinjing Li; Wei Wang; Hairui Yang
2009-05-15
The special phenomenon, nominated as bed inventory overturn, in circulating fluid bed (CFB) riser with pant-leg structure was studied with model calculation and experimental work. A compounded pressure drop mathematic model was developed and validated with the experimental data in a cold experimental test rig. The model calculation results agree well with the measured data. In addition, the intensity of bed inventory overturn is directly proportional to the fluidizing velocity and is inversely proportional to the branch point height. The results in the present study provide significant information for the design and operation of a CFB boiler with pant-leg structure.more » 15 refs., 10 figs., 1 tab.« less
Roll type conducting polymer legs for rigid-flexible thermoelectric generator
NASA Astrophysics Data System (ADS)
Park, Teahoon; Lim, Hanwhuy; Hwang, Jong Un; Na, Jongbeom; Lee, Hyunki; Kim, Eunkyoung
2017-07-01
A roll-type conducting polymer film was explored as a flexible organic p-type thermoelectric leg using poly(3,4-ethylenedioxythiophene) (PEDOT) doped with tosylate. The PEDOT films were prepared through solution casting polymerization and rolled up for a roll-type leg. Due to the high flexibility, the roll-type PEDOT leg enabled easy contact to both top and bottom electrodes. Simulation on the dynamic heat transfer and convective cooling for a vertically roosted rod- and roll-type PEDOT leg showed that the temperature difference (ΔT) between the hot and cold sides of the leg was much higher in the roll than that of the rod. The PEDOT legs were integrated with n-type Bi2Te3 blocks, to give a 36-couple rigid-flexible thermoelectric generator (RF-TEG). The maximum output voltage from the 36-couple RF-TEG under a ΔT of 7.9 K was determined as 36.7 mV along with a high output power of 115 nW. A wearable RF-TEG was prepared upon the combination of the 36-couple RF-TEG with an arm warmer, to afford an output voltage of 10.6 mV, which was generated constantly and steadily from human wrist heat.
Effect of cold indoor environment on physical performance of older women living in the community.
Lindemann, Ulrich; Oksa, Juha; Skelton, Dawn A; Beyer, Nina; Klenk, Jochen; Zscheile, Julia; Becker, Clemens
2014-07-01
the effects of cold on older persons' body and mind are not well documented, but with an increased number of older people with decreasing physical performance, these possible effects need to be understood. to investigate the effect of cold indoor environment on physical performance of older women. cross-sectional experimental study with two test conditions. movement laboratory in a climate chamber. eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). participants were exposed to moderately cold (15°C) and warm/normal (25°C) temperature in a climate chamber in random order with an interval of 1 week. The assessment protocol included leg extensor power (Nottingham Power Rig), sit-to-stand performance velocity (linear encoder), gait speed, walk-ratio (i.e. step length/cadence on an instrumented walk way), maximal quadriceps and hand grip strength. physical performance was lower in 15°C room temperature compared with 25°C room temperature for leg extensor power (P < 0.0001), sit-to-stand performance velocity (P < 0.0001), gait speed (P < 0.0001), walk-ratio (P = 0.016) and maximal quadriceps strength (P = 0.015), but not for hand grip strength. in healthy older women a moderately cold indoor environment decreased important physical performance measures necessary for independent living. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Influence of respiratory muscle work on VO(2) and leg blood flow during submaximal exercise.
Wetter, T J; Harms, C A; Nelson, W B; Pegelow, D F; Dempsey, J A
1999-08-01
The work of breathing (W(b)) normally incurred during maximal exercise not only requires substantial cardiac output and O(2) consumption (VO(2)) but also causes vasoconstriction in locomotor muscles and compromises leg blood flow (Q(leg)). We wondered whether the W(b) normally incurred during submaximal exercise would also reduce Q(leg). Therefore, we investigated the effects of changing the W(b) on Q(leg) via thermodilution in 10 healthy trained male cyclists [maximal VO(2) (VO(2 max)) = 59 +/- 9 ml. kg(-1). min(-1)] during repeated bouts of cycle exercise at work rates corresponding to 50 and 75% of VO(2 max). Inspiratory muscle work was 1) reduced 40 +/- 6% via a proportional-assist ventilator, 2) not manipulated (control), or 3) increased 61 +/- 8% by addition of inspiratory resistive loads. Increasing the W(b) during submaximal exercise caused VO(2) to increase; decreasing the W(b) was associated with lower VO(2) (DeltaVO(2) = 0.12 and 0.21 l/min at 50 and 75% of VO(2 max), respectively, for approximately 100% change in W(b)). There were no significant changes in leg vascular resistance (LVR), norepinephrine spillover, arterial pressure, or Q(leg) when W(b) was reduced or increased. Why are LVR, norepinephrine spillover, and Q(leg) influenced by the W(b) at maximal but not submaximal exercise? We postulate that at submaximal work rates and ventilation rates the normal W(b) required makes insufficient demands for VO(2) and cardiac output to require any cardiovascular adjustment and is too small to activate sympathetic vasoconstrictor efferent output. Furthermore, even a 50-70% increase in W(b) during submaximal exercise, as might be encountered in conditions where ventilation rates and/or inspiratory flow resistive forces are higher than normal, also does not elicit changes in LVR or Q(leg).
... or heaviness in legs lack of energy cold, gray skin irregular or slow heartbeat If you experience any of the following symptoms, stop taking canagliflozin and call your doctor immediately or get emergency medical treatment: rash hives itching difficulty swallowing swelling of the ...
Pretest analysis document for Test S-NH-1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owca, W.A.
This report documents the pretest analysis calculation completed with the RELAP5/MOD2/CY3601 code for Semiscale MOD-2C Test S-NH-1. The test will simulate the shear of a small diameter penetration of a cold leg, equivalent to 0.5% of the cold leg flow area. The high pressure injection system is assumed to be inoperative throughout the transient. The recovery procedure consists of latching open both steam generator ADV's while feeding with auxiliary feedwater, and accumulator operation. Recovery will be initiated upon a peak cladding temperature of 811 K (1000/sup 0/F). The test will be terminated when primary pressure has been reduced to themore » low pressure injection system setpoint of 1.38 MPa (200 psia). The calculated results indicate that the test objectives can be achieved and the proposed test scenario poses no threat to personnel or to plant integrity. 12 figs.« less
Dharmaretnam, Meena; Vijitha, V; Priyadharshini, K; Jashini, T; Vathany, K
2002-10-01
Lateralisation of a variety of visual functions: food discrimination, fear response, copulation, and performance of topographical and other tasks, such as olfactory and auditory functions, have been described in the domestic chick, Gallus gallus domesticus. A bias to left hemisphere control on day 8 and to the right on day 11 has also been demonstrated in the domestic chick. In this study we show that motor control as to foot preference in initiating a scratching bout and a tape-removing task is lateralised in both adults and chicks. There was a preference for the right leg to initiate a bout of ground scratching in both male and female adult birds. Second, foot preference is also affected by the changes in shifts of bias on day 8 and day 11. The right leg preference in initiating a ground scratching bout observed on day 5 is reversed to a left leg preference on day 8. This then reverts to the right leg preference after day 11. Hence it is postulated that the hemisphere that is not activated due to the bias of age controls the first leg to be used in initiating routine movements such as ground scratching. For the tape-removing task the right leg was used to remove a tape adhered to the beak of the chick for the trained group on day 8; but there was no preference in the naive group. Similarly, on day 11 a left foot bias was observed for the trained group and right foot bias for the naive group. To remove a tape the activated hemisphere on days of bias is used; whereas in a novel situation the foot use is reversed. Thus, footedness is affected by age, type of task, and changing hemispheric dominance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, P.; Umminger, K.J.; Schoen, B.
1995-09-01
The thermal hydraulic behavior of a PWR during beyond-design-basis accident scenarios is of vital interest for the verification and optimization of accident management procedures. Within the scope of the German reactor safety research program experiments were performed in the volumetrically scaled PKL 111 test facility by Siemens/KWU. This highly instrumented test rig simulates a KWU-design PWR (1300 MWe). In particular, the latest tests performed related to a SBLOCA with additional system failures, e.g. nitrogen entering the primary system. In the case of a SBLOCA, it is the goal of the operator to put the plant in a condition where themore » decay heat can be removed first using the low pressure emergency core cooling system and then the residual heat removal system. The experimental investigation presented assumed the following beyond-design-basis accident conditions: 0.5% break in a cold leg, 2 of 4 steam generators (SGs) isolated on the secondary side (feedwater- and steam line-valves closed), filled with steam on the primary side, cooldown of the primary system using the remaining two steam generators, high pressure injection system only in the two loops with intact steam generators, if possible no operator actions to reach the conditions for residual heat removal system activation. Furthermore, it was postulated that 2 of the 4 hot leg accumulators had a reduced initial water inventory (increased nitrogen inventory), allowing nitrogen to enter the primary system at a pressure of 15 bar and nearly preventing the heat transfer in the SGs ({open_quotes}passivating{close_quotes} U-tubes). Due to this the heat transfer regime in the intact steam generators changed remarkably. The primary system showed self-regulating system effects and heat transfer improved again (reflux-condenser mode in the U-tube inlet region).« less
Chemically synthesized boron carbon oxynitride as a new cold cathode material
NASA Astrophysics Data System (ADS)
Banerjee, Diptonil; Maity, Supratim; Chattopadhyay, K. K.
2015-11-01
Synthesis of boron carbon oxynitride (BCNO) nanosheets at different temperature from amorphous to crystalline regime has been reported. The synthesis was done by a simple molten salt process using sodium borohydride and urea as precursors. Transmission electron microscopic study confirms the formation of sheet-like structure of the as-synthesized material. The performances of the as-synthesized BCNO nanosheets as cold cathode materials have been studied for the first time in the high vacuum electron field emission set up. It has been seen that the material gives considerable field emission current with turn on field as low as 2.95 V/μm with good stability and thus a new cold cathode material can be postulated.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-25
..., with applicable safety factors applied. Application of the limited hot and cold leg tubesheet...-stamps the document and sends the submitter an email notice confirming receipt of the document. The E...
Life on Mars? II. Physical restrictions
NASA Technical Reports Server (NTRS)
Mancinelli, R. L.; Banin, A.
1995-01-01
The primary physical factors important to life's evolution on a planet include its temperature, pressure and radiation regimes. Temperature and pressure regulate the presence and duration of liquid water on the surface of Mars. The prolonged presence of liquid water is essential for the evolution and sustained presence of life on a planet. It has been postulated that Mars has always been a cold dry planet; it has also been postulated that early mars possessed a dense atmosphere of CO2 (> or = 1 bar) and sufficient water to cut large channels across its surface. The degree to which either of these postulates is true correlates with the suitability of Mars for life's evolution. Although radiation can destroy living systems, the high fluxes of UV radiation on the martian surface do not necessarily stop the origin and early evolution of life. The probability for life to have arisen and evolved to a significant degree on Mars, based on the postulated ranges of early martian physical factors, is almost solely related to the probability of liquid water existing on the planet for at least hundreds of millions to billions of years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Subhasish; Soppet, William K.; Majumdar, Saurin
In this paper, we present thermal-mechanical stress analysis of a pressurized water reactor pressure vessel and its hot-leg and cold-leg nozzles. Results are presented from thermal and thermal-mechanical stress analysis under reactor heat-up, cool-down, and grid load-following conditions. Analysis results are given with and without the presence of preexisting crack in the reactor nozzle (axial crack in hot leg nozzle). From the model results it is found that the stress-strain states are significantly higher in case of presence of crack than without crack. In conclusion, the stress-strain state under grid load following condition are more realistic compared to the stress-strainmore » state estimated assuming simplified transients.« less
Mohanty, Subhasish; Soppet, William K.; Majumdar, Saurin; ...
2016-10-26
In this paper, we present thermal-mechanical stress analysis of a pressurized water reactor pressure vessel and its hot-leg and cold-leg nozzles. Results are presented from thermal and thermal-mechanical stress analysis under reactor heat-up, cool-down, and grid load-following conditions. Analysis results are given with and without the presence of preexisting crack in the reactor nozzle (axial crack in hot leg nozzle). From the model results it is found that the stress-strain states are significantly higher in case of presence of crack than without crack. In conclusion, the stress-strain state under grid load following condition are more realistic compared to the stress-strainmore » state estimated assuming simplified transients.« less
Clapham, David E.; Miller, Christopher
2011-01-01
The exceptionally high temperature sensitivity of certain transient receptor potential (TRP) family ion channels is the molecular basis of hot and cold sensation in sensory neurons. The laws of thermodynamics dictate that opening of these specialized TRP channels must involve an unusually large conformational standard-state enthalpy, ΔHo: positive ΔHo for heat-activated and negative ΔHo for cold-activated TRPs. However, the molecular source of such high-enthalpy changes has eluded neurobiologists and biophysicists. Here we offer a general, unifying mechanism for both hot and cold activation that recalls long-appreciated principles of protein folding. We suggest that TRP channel gating is accompanied by large changes in molar heat capacity, ΔCP. This postulate, along with the laws of thermodynamics and independent of mechanistic detail, leads to the conclusion that hot- and cold-sensing TRPs operate by identical conformational changes. PMID:22109551
Clapham, David E; Miller, Christopher
2011-12-06
The exceptionally high temperature sensitivity of certain transient receptor potential (TRP) family ion channels is the molecular basis of hot and cold sensation in sensory neurons. The laws of thermodynamics dictate that opening of these specialized TRP channels must involve an unusually large conformational standard-state enthalpy, ΔH(o): positive ΔH(o) for heat-activated and negative ΔH(o) for cold-activated TRPs. However, the molecular source of such high-enthalpy changes has eluded neurobiologists and biophysicists. Here we offer a general, unifying mechanism for both hot and cold activation that recalls long-appreciated principles of protein folding. We suggest that TRP channel gating is accompanied by large changes in molar heat capacity, ΔC(P). This postulate, along with the laws of thermodynamics and independent of mechanistic detail, leads to the conclusion that hot- and cold-sensing TRPs operate by identical conformational changes.
WEATHER RELATED VARIABILITY OF CALORIMETERY PERFORMANCE IN A POORLY CONTROLLED ENVIRONMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
CAMERON, M.A.
2007-04-16
Four Antech airbath calorimeters at the Hanford site were studied for three summers and two winters in a location not well-shielded from outside temperature changes. All calorimeters showed significant increases in variability of standard measurements during hot weather. The increased variability is postulated to be due to a low setting of the Peltier cold face temperature, which doesn't allow the instrument to drain heat fast enough in a hot environment. A higher setting of the Peltier cold face might lead to better performance in environments subjected to a broad range of temperatures.
WEATHER RELATED VARIABILITY OF CALORIMETERY PERFORMANCE IN A POORLY CONTROLLED ENVIRONMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
CAMERON, M.A.
2007-04-16
Four Antech airbath calorimeters at the Hanford site were studied for three summers and two winters in a location not well-shielded from outside temperature changes. Calorimeters showed significant increases in variability of standard measurements during hot weather. The increased variability is postulated to be due to a low setting of the Peltier cold face temperature, which doesn't allow the instrument to drain heat fast enough in a hot environment. A higher setting of the Peltier cold face might lead to better performance in environments subjected to a broad range of temperatures.
Carcass characteristics of lambs fed spineless cactus as a replacement for sugarcane.
de Oliveira, Juliana Paula Felipe; de Andrade Ferreira, Marcelo; Alves, Adryanne Marjorie Souza Vitor; de Melo, Ana Caroline Cerqueira; de Andrade, Ida Barbosa; Urbano, Stela Antas; Suassuna, Juraci Marcos Alves; de Barros, Leonardo José Assis; de Barros Melo, Tobias Tobit
2018-04-01
Fresh sugarcane has been a new roughage source for ruminant's in semiarid regions, a function of the decline of sugar and alcohol industry in recent years. However, there is little data published regarding lambs fed sugarcane associated with spineless cactus. This study evaluated the effect of sugarcane replacement with spineless cactus (0%, 33%, 66%, and 100%) in the diet of Santa Inês lambs on carcass characteristics. Thirty-six non-castrated Santa Ines lambs at four months of age and an initial body weight of 22±2.3 kg were assigned in a randomized block design and slaughtered after 70 days of confinement. The effects of spineless cactus as a replacement for sugarcane in the diet of the lambs on the carcass characteristics, commercial cut weight and yield, leg tissue composition, and carcass measurements were studied. The study revealed quadratic behavior in slaughter body weight, and hot and cold carcass weight, with maximum values of 38.60, 18.60, and 18.11 kg and replacement levels of 40.18%, 44.42%, and 43.14%, respectively. The cold carcass yield presented an increasing linear behavior. The compactness index of carcass and leg presented a quadratic effect, with estimated maximal values of 0.28 and 0.57 kg/cm and replacement levels of 43.37% and 45.5%, respectively. The weights of commercial cuts of leg, loin, shoulder, and breast showed quadratic behavior, with maximum values of 2.79, 0.852, 1.46, and 1.30 kg and replacement levels of 49.5, 45.32, 39.0, and 40.7, respectively. For tissue composition, quadratic behavior was verified for leg weight, subcutaneous fat, and total fat. The replacement of sugarcane by spineless cactus at level 44% is recommended for finishing lambs considering that this level improved most of the carcass characteristics, weights, and yields of commercial cuts and leg tissue composition.
Tolerance of an Antarctic Bacterium to Multiple Environmental Stressors.
Sengupta, Dipanwita; Sangu, Kavya; Shivaji, Sisinthy; Chattopadhyay, Madhab K
2015-10-01
A population of cold-tolerant Antarctic bacteria was screened for their ability to tolerate other environmental stress factors. Besides low temperature, they were predominantly found to be tolerant to alkali. Attempt was also made to postulate a genetic basis of their multistress-tolerance. Transposon mutagenesis of an isolate Pseudomonas syringae Lz4W was performed, and mutants with delayed growth at low temperature were further screened for sensitivity to some other stress factors. A number of multistress-sensitive mutants were isolated. The mutated gene in one of the mutants sensitive to low temperature, acid and alkali was found to encode citrate synthase. Possible role of citrate synthase in conferring multistress-tolerance was postulated.
Investigation of Hypersonic Nozzle Flow Uniformity Using NO Fluorescence
NASA Technical Reports Server (NTRS)
O'Byrne, S.; Danehy, P. J.; Houwing, A. F. P.
2005-01-01
Planar laser-induced fluorescence visualisation is used to investigate nonuniformities in the flow of a hypersonic conical nozzle. Possible causes for the nonuniformity are outlined and investigated, and the problem is shown to be due to a small step at the nozzle throat. Entrainment of cold boundary layer gas is postulated as the cause of the signal nonuniformity.
Pharmacists counselling of pregnant women: Web-based, comparative study between Serbia and Norway.
Odalović, Marina; Milanković, Silje; Holst, Lone; Nordeng, Hedvig; Heitmann, Kristine; Tasić, Ljiljana
2016-09-01
To describe, compare and evaluate whether pharmacists in two European countries, Serbia and Norway, give appropriate counselling for common ailments in pregnancy. A cross sectional, web-based study. A study was conducted among Serbian and Norwegian pharmacists during two four-month study periods in 2012 respectively 2014. Participants were recruited through postal and electronic invitation facilitated by several pharmacy chains. Participation in the study was anonymous and voluntary. Pharmacists were presented with the questionnaire that included five scenarios (back pain, heavy legs, nausea, cold and constipation in pregnancy) and were asked to give their advice about use of medicines, supplements (e.g. herbal products, vitamins, minerals), non-pharmacological treatment and referral to physician in each condition. In total, 276 pharmacists, 119 in Serbia and 157 in Norway, accepted to participate in the study. Recommendation about medicines use ranged from 32% (heavy legs) to 71% (back pain) in Serbia and from 3% (heavy legs) to 92% (constipation) in Norway. Several pharmacists' recommendations on medicines and supplements use were inappropriate. Recommendation about non-pharmacological treatments ranged from 11% (nausea) to 50% (heavy legs) in Serbia and from 12% (constipation) to 63% (cold) in Norway. Approximately 12% of the Norwegian and Serbian pharmacists offered referral to a physician as only advice for nausea in pregnancy, indicating a lack of confidence in or knowledge about this common ailment in pregnancy. Large differences in counselling of pregnant women by pharmacists in Serbia and Norway were observed. Enhancement of pharmacists' knowledge about treatment of common ailments in pregnancy is needed and will enhance pharmacists' role in improving maternal health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Computer modeling of thermoelectric generator performance
NASA Technical Reports Server (NTRS)
Chmielewski, A. B.; Shields, V.
1982-01-01
Features of the DEGRA 2 computer code for simulating the operations of a spacecraft thermoelectric generator are described. The code models the physical processes occurring during operation. Input variables include the thermoelectric couple geometry and composition, the thermoelectric materials' properties, interfaces and insulation in the thermopile, the heat source characteristics, mission trajectory, and generator electrical requirements. Time steps can be specified and sublimation of the leg and hot shoe is accounted for, as are shorts between legs. Calculations are performed for conduction, Peltier, Thomson, and Joule heating, the cold junction can be adjusted for solar radition, and the legs of the thermoelectric couple are segmented to enhance the approximation accuracy. A trial run covering 18 couple modules yielded data with 0.3% accuracy with regard to test data. The model has been successful with selenide materials, SiGe, and SiN4, with output of all critical operational variables.
Topological phases in frustrated synthetic ladders with an odd number of legs
NASA Astrophysics Data System (ADS)
Barbarino, Simone; Dalmonte, Marcello; Fazio, Rosario; Santoro, Giuseppe E.
2018-01-01
The realization of the Hofstadter model in a strongly anisotropic ladder geometry has now become possible in one-dimensional optical lattices with a synthetic dimension. In this work, we show how the Hofstadter Hamiltonian in such ladder configurations hosts a topological phase of matter which is radically different from its two-dimensional counterpart. This topological phase stems directly from the hybrid nature of the ladder geometry and is protected by a properly defined inversion symmetry. We start our analysis by considering the paradigmatic case of a three-leg ladder which supports a topological phase exhibiting the typical features of topological states in one dimension: robust fermionic edge modes, a degenerate entanglement spectrum, and a nonzero Zak phase; then, we generalize our findings—addressable in the state-of-the-art cold-atom experiments—to ladders with a higher number of legs.
Traynor, Robyn; MacDermid, Joy C
2008-09-01
Intolerance to the cold is common following peripheral nerve injury and surgery of the upper extremity. Despite its prevalence, the exact pathophysiology and natural history of this condition are not well understood. Subjective, self-report questionnaires have been created and validated as reliable measures of post-traumatic cold intolerance. The difficulty currently lies in assigning an objective measure to this predominantly subjective phenomenon. The present study evaluated the test-retest reliability of a proposed objective measure of cold intolerance, the Immersion in Cold-water Evaluation (ICE), and its correlation with subjective measures in healthy control subjects. Two age groups were also compared to investigate the effect of age on cold intolerance and temperature recovery. On two separate testing days, subjects completed three health-related questionnaires and submersed their dominant hands in cold water. The temperature of their second and fifth digits was monitored during recovery. Both the objective cold-provocation testing and the subjective self-report questionnaires were highly reliable albeit not significantly correlated. No significant temperature recovery trend was noted between the age groups. Post-traumatic cold intolerance is postulated to have both a vascular and neural etiology among other contributing causes. The protocol studied here was centered predominantly on the former etiology, examining peripheral blood flow and associated temperature recovery. This study established ICE as a reliable means to objectively measure cold response, supplementing information provided by previously validated self-report methods.
Electrical, Thermal, and Mechanical Characterization of Novel Segmented-Leg Thermoelectric Modules
NASA Astrophysics Data System (ADS)
D'Angelo, Jonathan; Case, Eldon D.; Matchanov, Nuraddin; Wu, Chun-I.; Hogan, Timothy P.; Barnard, James; Cauchy, Charles; Hendricks, Terry; Kanatzidis, Mercouri G.
2011-10-01
In this paper we report on the electrical, thermal, and mechanical characterization of segmented-leg PbTe-based thermoelectric modules. This work featured a thermoelectric module measurement system that was constructed and used to measure 47-couple segmented thermoelectric power generation modules fabricated by Tellurex Corporation using n-type Bi2Te3- x Se x to Ag0.86Pb19+ x SbTe20 legs and p-type Bi x Sb2- x Te3 to Ag0.9Pb9Sn9Sb0.6Te20 legs. The modules were measured under vacuum with hot-side and cold-side temperatures of approximately 670 K and 312 K, respectively. In addition, the measurements on the PbTe-based materials are compared with measurements performed on Bi2Te3 reference modules. Efficiency values as high as 6.56% were measured on these modules. In addition to the measurement system description and the measurement results on these modules, infrared images of the modules that were used to help identify nonuniformities are also presented.
Key to Prevention of Bradycardia: Be Relax Postoperatively: A Case Report.
Chowdhury, Tumul; Schaller, Bernhard
2016-05-01
Hypotension and bradycardia are commonly observed after the spinal anesthesia and various mechanisms have been postulated for these hemodynamic changes.A middle-aged otherwise healthy male Caucasian patient developed several episodes of bradycardia postoperatively after the umbilical hernia repair under subarachnoid block (SAB) while trying to lean forward and move his legs. Episodes were aborted when patient was advised to relax in supine position.The common mechanism of bradycardia and hypotension under SAB is postulated as sympathetic blockade, decrease venous return, and parasympathetic over-dominance leading to a decrease in right arterial pressure and pressure in the great veins as they enter the right atrium. But over time, the parasympathetic inhibition is usually withdrawn first, leading to the risk of severe bradycardia that is probably favored by the reverse Trendelenburg position as described in our case.Postoperative severe hemodynamic changes can occur even under stable spinal anesthesia; however, can be prevented by vigilant monitoring and simple maneuver which includes maintenance of relax posture on the bed.
Diabetic Foot and Risk: How to Prevent Losing Your Leg
... in blood flow to the foot. Darkening or loss of hair may indicate that the blood or nerve supply has decreased. Less blood to the foot can ... differences between hot/warm and cold water. Shower water can be first tested ... identify any loss of temperature sensation. Testing for any change in ...
Pretest analysis document for Test S-NH-2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Streit, J.E.; Owca, W.A.
This report documents the pretest analysis calculation completed with the RELAP5/MOD2/CY3601 code for Semiscale MOD-2C Test S-NH-2. The test will simulate the transient that results from the shear in a small diameter penetration of a cold leg, equivalent to 2.1% of the cold leg flow area. The high pressure injection system is assumed to be inoperative throughout the transient. The recovery procedure consists of latching open both steam generator atmospheric dump valves, supplying both steam generators with auxiliary feedwater system is assumed to be partially inoperative so the auxiliary feedwater flow is degraded. Recovery will be initiated upon a peakmore » cladding temperature of 811/sup 0/K (1000/sup 0/F). The test will be terminated when primary pressure has been reduced to the low pressure injection system setpoint of 1.38 MPa (200 psia). The calculated results indicate that the test objectives can be achieved and the proposed test scenario poses no threat to personnel or to plant integrity. 7 refs., 16 figs., 2 tabs.« less
NASA Astrophysics Data System (ADS)
Matuo, Youichirou; Miyahara, Shinya; Izumi, Yoshinobu
Radioactive Corrosion Product (CP) is a main cause of personal radiation exposure during maintenance with no breached fuel in fast breeder reactor (FBR) plants. The most important CP is 54Mn and 60Co. In order to establish techniques of radiation dose estimation for radiation workers in radiation-controlled areas of the FBR, the PSYCHE (Program SYstem for Corrosion Hazard Evaluation) code was developed. We add the Particle Model to the conventional PSYCHE analytical model. In this paper, we performed calculation of CP transfer in JOYO using an improved calculation code in which the Particle Model was added to the PSYCHE. The C/E (calculated / experimentally observed) value for CP deposition was improved through use of this improved PSYCHE incorporating the Particle Model. Moreover, among the percentage of total radioactive deposition accounted for by CP in particle form, 54Mn was estimated to constitute approximately 20 % and 60Co approximately 40 % in the cold-leg region. These calculation results are consistent with the measured results for the actual cold-leg piping in the JOYO.
Warm-up with a weighted vest improves running performance via leg stiffness and running economy.
Barnes, K R; Hopkins, W G; McGuigan, M R; Kilding, A E
2015-01-01
To determine the effects of "strides" with a weighted-vest during a warm-up on endurance performance and its potential neuromuscular and metabolic mediators. A bout of resistance exercise can enhance subsequent high-intensity performance, but little is known about such priming exercise for endurance performance. A crossover with 5-7 days between an experimental and control trial was performed by 11 well-trained distance runners. Each trial was preceded by a warm-up consisting of a 10-min self-paced jog, a 5-min submaximal run to determine running economy, and six 10-s strides with or without a weighted-vest (20% of body mass). After a 10-min recovery period, runners performed a series of jumps to determine leg stiffness and other neuromuscular characteristics, another 5-min submaximal run, and an incremental treadmill test to determine peak running speed. Clinical and non-clinical forms of magnitude-based inference were used to assess outcomes. Correlations and linear regression were used to assess relationships between performance and underlying measures. The weighted-vest condition resulted in a very-large enhancement of peak running speed (2.9%; 90% confidence limits ±0.8%), a moderate increase in leg stiffness (20.4%; ±4.2%) and a large improvement in running economy (6.0%; ±1.6%); there were also small-moderate clear reductions in cardiorespiratory measures. Relationships between change scores showed that changes in leg stiffness could explain all the improvements in performance and economy. Strides with a weighted-vest have a priming effect on leg stiffness and running economy. It is postulated the associated major effect on peak treadmill running speed will translate into enhancement of competitive endurance performance. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Evaluation of the KIN and DUI Passive Thermal Survival Systems: Deep Dive 92
1993-04-01
orofacial mask, pain on bridge of my nose. BI-Cold and uncomfortable, with a headache. My shoulders, upper arms, feet, lower legs, and back were very cold...and DUI 20 9 Oronasal Gas Temps--KIN vs. DUI 21 10 Average Oxygen in Orofacial Masks--KIN vs. DUI - All Trials 22 11 DUI: Average Oxygen--Three Trials...Oxygen in Orofacial Masks-KIN vs. DUI ALL TRIALS 50 - 45 40 W 35 o30 25 DUI-Bold Lines 20 KIN-Light Lines 15 I 0 2 4 6 8 10 12 HOURS in cooling profile
MID-VASTUS VS MEDIAL PARA-PATELLAR APPROACH IN TOTAL KNEE REPLACEMENT—TIME TO DISCHARGE
Mukherjee, P.; Press, J.; Hockings, M.
2009-01-01
Background It has been shown before that when compared with the medial para-patellar approach, the mid-vastus approach for TKR results in less post-operative pain for patients and more rapid recovery of straight leg raise. As far as we are aware the post-operative length of stay of the two groups of patients has not been compared. We postulated that the reduced pain and more rapid recovery of straight leg raise would translate into an earlier, safe, discharge home for the mid-vastus patients compared with those who underwent a traditional medial para-patellar approach. Methods Twenty patients operated on by each of five established knee arthroplasty surgeons were evaluated prospectively with regard to their pre and post-operative range of movement, time to achieve straight leg raise post-operatively and length of post-operative hospital stay. Only one of the surgeons performed the mid-vastus approach, and the measurements were recorded by physiotherapists who were blinded as to the approach used on each patient. Results The results were analysed using a standard statistical software package, and although the mean length of stay was lower for the mid-vastus patients, the difference did not reach a level of significance (p = 0.13). The time taken to achieve straight leg raise post-operatively was significantly less in the mid-vastus group (p<0.001). Conclusion Although this study confirms previous findings that the mid-vastus approach reduces the time taken for patients to achieve straight leg raise, when compared with the medial para-patellar approach, on its own it does not translate into a significantly shorter length of hospital stay. In order to reduce the length of post-operative hospital stay with an accelerated rehabilitation program for TKR, a multi-disciplinary approach is required. Patient expectations, GP support, physiotherapists and nursing staff all have a role to play and the mid-vastus approach, in permitting earlier straight leg raising, significantly contributes to this. PMID:19742080
Ankle Joint Angle and Lower Leg Musculotendinous Unit Responses to Cryotherapy.
Akehi, Kazuma; Long, Blaine C; Warren, Aric J; Goad, Carla L
2016-09-01
Akehi, K, Long, BC, Warren, AJ, and Goad, CL. Ankle joint angle and lower leg musculotendinous unit responses to cryotherapy. J Strength Cond Res 30(9): 2482-2492, 2016-The use of cold application has been debated for its influence on joint range of motion (ROM) and stiffness. The purpose of this study was to determine whether a 30-minute ice bag application to the plantarflexor muscles or ankle influences passive ankle dorsiflexion ROM and lower leg musculotendinous stiffness (MTS). Thirty-five recreationally active college-aged individuals with no history of lower leg injury 6 months before data collection volunteered. On each testing day, we measured maximum passive ankle dorsiflexion ROM (°) and plantarflexor torque (N·m) on an isokinetic dynamometer to calculate the passive plantarflexor MTS (N·m per degree) at 4 joint angles before, during, and after a treatment. Surface electromyography amplitudes (μV), and skin surface and ambient air temperature (°C) were also measured. Subjects received an ice bag to the posterior lower leg, ankle joint, or nothing for 30 minutes in different days. Ice bag application to the lower leg and ankle did not influence passive ROM (F(12,396) = 0.67, p = 0.78). Passive torque increased after ice bag application to the lower leg (F(12,396) = 2.21, p = 0.011). Passive MTS at the initial joint angle increased after ice bag application to the lower leg (F(12,396) = 2.14, p = 0.014) but not at the other joint angles (p > 0.05). Surface electromyography amplitudes for gastrocnemius and soleus muscles increased after ice application to the lower leg (F(2,66) = 5.61, p = 0.006; F(12,396) = 3.60, p < 0.001). Ice bag application to the lower leg and ankle joint does not alter passive dorsiflexion ROM but increases passive ankle plantarflexor torque in addition to passive ankle plantarflexor MTS at the initial joint angle.
Preliminary Design of Critical Function Monitoring System of PGSFR
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-07-01
A PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) is under development at Korea Atomic Energy Research Institute. A critical function monitoring system of the PGSFR is preliminarily studied. The functions of CFMS are to display critical plant variables related to the safety of the plant during normal and accident conditions and guide the operators corrective actions to keep the plant in a safe condition and mitigate the consequences of accidents. The minimal critical functions of the PGSFR are composed of reactivity control, reactor core cooling, reactor coolant system integrity, primary heat transfer system(PHTS) heat removal, sodium water reaction mitigation, radiation controlmore » and containment conditions. The variables and alarm legs of each critical function of the PGSFR are as follows; - Reactivity control: The variables of reactivity control function are power range neutron flux instrumentation, intermediate range neutron flux instrumentation, source range neutron flux instrumentation, and control rod bottom contacts. The alarm leg to display the reactivity controls consists of status of control drop malfunction, high post trip power and thermal reactivity addition. - Reactor core cooling: The variables are PHTS sodium level, hot pool temperature of PHTS, subassembly exit temperature, cold pool temperature of the PHTS, PHTS pump current, and PHTS pump breaker status. The alarm leg consists of high core delta temperature, low sodium level of the PHTS, high subassembly exit temperature, and low PHTS pump load. - Reactor coolant system integrity: The variables are PHTS sodium level, cover gas pressure, and safeguard vessel sodium level. The alarm leg is composed of low sodium level of PHTS, high cover gas pressure and high sodium level of the safety guard vessel. - PHTS heat removal: The variables are PHTS sodium level, hot pool temperature of PHTS, core exit temperature, cold pool temperature of the PHTS, flow rate of passive residual heat removal system, flow rate of active residual heat removal system, and temperatures of air heat exchanger temperature of residual heat removal systems. The alarm legs are composed of two legs of a 'passive residual heat removal system not cooling' and 'active residual heat removal system not cooling'. - Sodium water reaction mitigation: The variables are intermediate heat transfer system(IHTS) pressure, pressure and temperature and level of sodium dump tank, the status of rupture disk, hydrogen concentration in IHTS and direct variable of sodium-water-reaction measure. The alarm leg consists of high IHTS pressure, the status of sodium water reaction mitigation system and the indication of direct measure. - Radiation control: The variables are radiation of PHTS, radiation of IHTS, and radiation of containment purge. The alarm leg is composed of high radiation of PHTS and IHTS, and containment purge system. - Containment condition: The variables are containment pressure, containment isolation status, and sodium fire. The alarm leg consists of high containment pressure, status of containment isolation and status of sodium fire. (authors)« less
Kahanov, Leamor; Eberman, Lindsey E; Wasik, Mitchell; Alvey, Thurman
2012-01-01
To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive coldwater immersion. A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated postpractice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45-260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal < 6.7 ng/mL), and CK-myoglobin relative index of 30% (normal range, 25%-30%). Myoglobin was measured at 499 ng/mL (normal = 80 ng/mL). The attending physician treated the athlete with intravenous fluids. Exercise-associated muscle cramps, dehydration, exertional rhabdomyolysis. The patient was treated with rest and rehydration. One week after the incident, he began biking and swimming. Eighteen days later, the patient continued to demonstrate elevated CK levels (527 IU/L) but described no other symptoms and was allowed to return to football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence.
Nonlinear mode interaction in equal-leg angle struts susceptible to cellular buckling.
Bai, L; Wang, F; Wadee, M A; Yang, J
2017-11-01
A variational model that describes the interactive buckling of a thin-walled equal-leg angle strut under pure axial compression is presented. A formulation combining the Rayleigh-Ritz method and continuous displacement functions is used to derive a system of differential and integral equilibrium equations for the structural component. Solving the equations using numerical continuation reveals progressive cellular buckling (or snaking) arising from the nonlinear interaction between the weak-axis flexural buckling mode and the strong-axis flexural-torsional buckling mode for the first time-the resulting behaviour being highly unstable. Physical experiments conducted on 10 cold-formed steel specimens are presented and the results show good agreement with the variational model.
Kahanov, Leamor; Eberman, Lindsey E.; Wasik, Mitchell; Alvey, Thurman
2012-01-01
Objective: To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive cold-water immersion. Background: A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated post-practice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45–260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal < 6.7 ng/mL), and CK-myoglobin relative index of 30% (normal range, 25%– 30%). Myoglobin was measured at 499 ng/mL (normal = 80 ng/mL). The attending physician treated the athlete with intravenous fluids. Differential Diagnosis: Exercise-associated muscle cramps, dehydration, exertional rhabdomyolysis. Treatment: The patient was treated with rest and rehydration. One week after the incident, he began biking and swimming. Eighteen days later, the patient continued to demonstrate elevated CK levels (527 IU/L) but described no other symptoms and was allowed to return to football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). Uniqueness: The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. Conclusions: In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence. PMID:22488291
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katz, O.M.
1968-02-01
Empirical kinetic equations were derived to describe the recovery region between 550 and 1020/sup 0/F for times to 4000 hours for 15 to 78% cold-worked Zircaloy-4 plate and tubing. The properties studied were electrical resistivity and X-ray line sharpening. Recrystallization kinetics were described with sigmoidal curves derived from X-ray intensity and microhardness data. Light, replica, and transmission electron microscopy and selected-area electron diffraction were used to postulate recovery and recrystallization mechanisms. From a structural aspect, the annealing process in cold-worked Zircaloy-4 is visualized as a dislocation climb and annihilation process to the limit allowed by the size of the deformationmore » subcells, a reorientation of the subgrain material into a recrystallization texture, a growth of reoriented cells located in the most highly worked bands, and a consumption of less favorably strained and/or oriented cells by the high-angle boundaries of the reoriented cells. Comparison of 15 and 73% cold-worked tubing showed the activation energy to be less (21 versus 60 kcal/mol) and the subcell size greater (8000A versus 1000A) for the 15% cold-worked material. (NSA 22: 21698)« less
The neuropathic postural tachycardia syndrome
NASA Technical Reports Server (NTRS)
Jacob, G.; Costa, F.; Shannon, J. R.; Robertson, R. M.; Wathen, M.; Stein, M.; Biaggioni, I.; Ertl, A.; Black, B.; Robertson, D.
2000-01-01
BACKGROUND: The postural tachycardia syndrome is a common disorder that is characterized by chronic orthostatic symptoms and a dramatic increase in heart rate on standing, but that does not involve orthostatic hypotension. Several lines of evidence indicate that this disorder may result from sympathetic denervation of the legs. METHODS: We measured norepinephrine spillover (the rate of entry of norepinephrine into the venous circulation) in the arms and legs both before and in response to exposure to three stimuli (the cold pressor test, sodium nitroprusside infusion, and tyramine infusion) in 10 patients with the postural tachycardia syndrome and in 8 age- and sex-matched normal subjects. RESULTS: At base line, the mean (+/-SD) plasma norepinephrine concentration in the femoral vein was lower in the patients with the postural tachycardia syndrome than in the normal subjects (135+/-30 vs. 215+/-55 pg per milliliter [0.80+/-0.18 vs. 1.27+/-0.32 nmol per liter], P=0.001). Norepinephrine spillover in the arms increased to a similar extent in the two groups in response to each of the three stimuli, but the increases in the legs were smaller in the patients with the postural tachycardia syndrome than in the normal subjects (0.001+/-0.09 vs. 0.12+/-0.12 ng per minute per deciliter of tissue [0.006+/-0.53 vs. 0.71+/-0.71 nmol per minute per deciliter] with the cold pressor test, P=0.02; 0.02+/-0.07 vs. 0.23+/-0.17 ng per minute per deciliter [0.12+/-0.41 vs. 1.36+/-1.00 nmol per minute per deciliter] with nitroprusside infusion, P=0.01; and 0.008+/-0.09 vs. 0.19+/-0.25 ng per minute per deciliter [0.05+/-0.53 vs. 1.12+/-1.47 nmol per minute per deciliter] with tyramine infusion, P=0.04). CONCLUSIONS: The neuropathic postural tachycardia syndrome results from partial sympathetic denervation, especially in the legs.
Samour, Mohamad Samir; Nagi, Saad Saulat; Shortland, Peter John; Mahns, David Anthony
2017-08-01
Minocycline, a glial suppressor, prevents behavioral hypersensitivities in animal models of peripheral nerve injury. However, clinical trials of minocycline in human studies have produced mixed results. This study addressed 2 questions: can repeated injections of hypertonic saline (HS) in humans induce persistent hypersensitivity? Can pretreatment with minocycline, a tetracycline antibiotic with microglial inhibitory effects, prevent the onset of hypersensitivity? Twenty-seven healthy participants took part in this double-blind, placebo-controlled study, consisting of 6 test sessions across 2 weeks. At the beginning of every session, pressure-pain thresholds of the anterior muscle compartment of both legs were measured to determine the region distribution and intensity of muscle soreness. To measure changes in thermal sensitivity in the skin overlying the anterior muscle compartment of both legs, quantitative sensory testing was used to measure the cutaneous thermal thresholds (cold sensation, cold pain, warm sensation, and heat pain) and a mild cooling stimulus was applied to assess the presence of cold allodynia. To induce ongoing hypersensitivity, repeated injections of HS were administered into the right tibialis anterior muscle at 48-hour intervals. In the final 2 sessions (days 9 and 14), only sensory assessments were done to plot the recovery after cessation of HS administrations and drug washout. By day 9, nontreated participants experienced a significant bilateral increase in muscle soreness (P < .0001), accompanied by the emergence of bilateral cold allodynia in 44% of participants, thus confirming the effectiveness of the model. Placebo-treated participants experienced a bilateral 35% alleviation in muscle soreness (P < .0001), with no changes to the prevalence of cold allodynia. In contrast, minocycline-treated participants experienced a bilateral 70% alleviation in muscle soreness (P < .0001), additionally, only 10% of minocycline-treated participants showed cold allodynia. This study showed that repeated injections of HS can induce a hypersensitivity that outlasts the acute response, and the development of this hypersensitivity can be reliably attenuated with minocycline pretreatment. Four repeated injections of HS at 48-hour intervals induce a state of persistent hypersensitivity in healthy human participants. This hypersensitivity was characterized by bilateral muscular hyperalgesia and cutaneous cold allodynia, symptoms commonly reported in many chronic pain conditions. Minocycline pretreatment abolished the development of this state. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Riise, Ellen Kristin; Lorentzen, Marit Sjo; Helland, Ronny; Smalås, Arne O; Leiros, Hanna-Kirsti S; Willassen, Nils Peder
2007-02-01
The cold-adapted catalase from the fish-pathogenic bacterium Vibrio salmonicida (VSC) has recently been characterized and shown to be two times more catalytically efficient compared with catalase from the mesophilic human pathogen Proteus mirabilis [PMC; Lorentzen et al. (2006), Extremophiles, 10, 427-440]. VSC is also less temperature-stable, with a half-life of 5 min at 333 K compared with 50 min for PMC. This was the background for solving the crystal structure of the cold-adapted VSC to 1.96 A and performing an extensive structural comparison of VSC and PMC. The comparison revealed that the entrance (the major channel) leading to the catalytically essential haem group, is locally more flexible and slightly wider in VSC. This might explain the enhanced catalytic efficiency of the nearly diffusion-controlled degradation of hydrogen peroxide into water and molecular oxygen in VSC. The reduced thermal stability of the cold-adapted VSC may be explained by a reduced number of ion-pair networks. The four C-terminal alpha-helices are displaced in the structures, probably owing to missing ionic interactions in VSC compared with PMC, and this is postulated as an initiation site for unfolding the cold-adapted enzyme. VSC is the first crystal structure reported of a cold-adapted monofunctional haem-containing catalase.
Suter, Clemens; Tomeš, Petr; Weidenkaff, Anke; Steinfeld, Aldo
2010-01-01
A heat transfer model that couples radiation/conduction/convection heat transfer with electrical potential distribution is developed for a thermoelectric converter (TEC) subjected to concentrated solar radiation. The 4-leg TEC module consists of two pairs of p-type La1.98Sr0.02CuO4 and n-type CaMn0.98Nb0.02O3 legs that are sandwiched between two ceramic Al2O3 hot/cold plates and connected electrically in series and thermally in parallel. The governing equations for heat transfer and electrical potential are formulated, discretized and solved numerically by applying the finite volume (FV) method. The model is validated in terms of experimentally measured temperatures and voltages/power using a set of TEC demonstrator modules, subjected to a peak radiative flux intensity of 300 suns. The heat transfer model is then applied to examine the effect of the geometrical parameters (e.g. length/width of legs) on the solar-to-electricity energy conversion efficiency.
ANALYSIS OF BORON DILUTION TRANSIENTS IN PWRS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DIAMOND,D.J.BROMLEY,B.P.ARONSON,A.L.
2004-02-04
A study has been carried out with PARCS/RELAP5 to understand the consequences of hypothetical boron dilution events in pressurized water reactors. The scenarios of concern start with a small-break loss-of-coolant accident. If the event leads to boiling in the core and then the loss of natural circulation, a boron-free condensate can accumulate in the cold leg. The dilution event happens when natural circulation is re-established or a reactor coolant pump (RCP) is restarted in violation of operating procedures. This event is of particular concern in B&W reactors with a lowered-loop design and is a Generic Safety Issue for the U.S.more » Nuclear Regulatory Commission. The results of calculations with the reestablishment of natural circulation show that there is no unacceptable fuel damage. This is determined by calculating the maximum fuel pellet enthalpy, based on the three-dimensional model, and comparing it with the criterion for damage. The calculation is based on a model of a B&W reactor at beginning of the fuel cycle. If an RCP is restarted, unacceptable fuel damage may be possible in plants with sufficiently large volumes of boron-free condensate in the cold leg.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spore, J.W.; Cappiello, M.W.; Dotson, P.J.
The analytical support in 1985 for Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF), and Upper Plenum Test Facility (UPTF) tests involves the posttest analysis of 16 tests that have already been run in the CCTF and the SCTF and the pretest analysis of 3 tests to be performed in the UPTF. Posttest analysis is used to provide insight into the detailed thermal-hydraulic phenomena occurring during the refill and reflood tests performed in CCTF and SCTF. Pretest analysis is used to ensure that the test facility is operated in a manner consistent with the expected behavior of anmore » operating full-scale plant during an accident. To obtain expected behavior of a plant during an accident, two plant loss-of-coolant-accident (LOCA) calculations were performed: a 200% cold-leg-break LOCA calculation for a 2772 MW(t) Babcock and Wilcox plant and a 200% cold-leg-break LOCA calculation for a 3315 MW(t) Westinghouse plant. Detailed results are presented for several CCTF UPI tests and the Westinghouse plant analysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, Per F.
A high-temperature containment-isolation system for transferring heat from a nuclear reactor containment to a high-pressure heat exchanger is presented. The system uses a high-temperature, low-volatility liquid coolant such as a molten salt or a liquid metal, where the coolant flow path provides liquid free surfaces a short distance from the containment penetrations for the reactor hot-leg and the cold-leg, where these liquid free surfaces have a cover gas maintained at a nearly constant pressure and thus prevent high-pressures from being transmitted into the reactor containment, and where the reactor vessel is suspended within a reactor cavity with a plurality ofmore » refractory insulator blocks disposed between an actively cooled inner cavity liner and the reactor vessel.« less
Pretorius, Thea; Lix, Lisa; Giesbrecht, Gordon
2011-03-01
Previous studies showed that core cooling rates are similar when only the head or only the body is cooled. Structural equation modeling was used on data from two cold water studies involving body-only, or whole body (including head) cooling. Exposure of both the body and head increased core cooling, while only body cooling elicited shivering. Body fat attenuates shivering and core cooling. It is postulated that this protection occurs mainly during body cooling where fat acts as insulation against cold. This explains why head cooling increases surface heat loss with only 11% while increasing core cooling by 39%. Copyright © 2011 Elsevier Ltd. All rights reserved.
Rotational effect of buoyancy in frontcrawl: Does it really cause the legs to sink?
Yanai, T
2001-02-01
The purposes of this study were to quantify the rotational effect of buoyant force (buoyant torque) during the performance of front crawl and to reexamine the mechanics of horizontal alignment of the swimmers. Three-dimensional videography was used to measure the position and orientation of the body segments of 11 competitive swimmers performing front crawl stroke at a sub-maximum sprinting speed. The dimensions of each body segment were defined mathematically to match the body segment parameters (mass, density, and centroid position) reported in the literature. The buoyant force and torque were computed for every video-field (60fields/s), assuming that the water surface followed a sine curve along the length of the swimmer. The average buoyant torque over the stroke cycle (mean=22Nm) was directed to raise the legs and lower the head, primarily because the recovery arm and a part of the head were lifted out of the water and the center of buoyancy shifted toward the feet. This finding contradicts the prevailing speculation that buoyancy only causes the legs to sink throughout the stroke cycle. On the basis of a theoretical analysis of the results, it is postulated that the buoyant torque, and perhaps the forces generated by kicks, function to counteract the torque generated by the hydrodynamic forces acting on the hands, so as to maintain the horizontal alignment of the body in front crawl.
Temperature uniformity in hyperthermal tumor therapy
NASA Technical Reports Server (NTRS)
Harrison, G. H.; Robinson, J. E.; Samaras, G. M.
1978-01-01
Mouse mammary tumors heated by water bath or by microwave-induced hyperthermia exhibit a response that varies sharply with treatment temperature; therefore, uniform heating of the tumor is essential to quantitate the biological response as a function of temperature. C3H tumors implanted on the mouse flank were easily heated to uniformities within 0.1 C by using water baths. Cold spots up to 1 C below the desired treatment temperature were observed in the same tumors implanted on the hind leg. These cold spots were attributed to cooling by major blood vessels near the tumor. In this case temperature uniformity was achieved by the deposition of 2450 MHz microwave energy into the tumor volume by using parallel-opposed applicators.
Best-estimate coupled RELAP/CONTAIN analysis of inadvertent BWR ADS valve opening transient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feltus, M.A.; Muftuoglu, A.K.
1993-01-01
Noncondensible gases may become dissolved in boiling water reactor (BWR) water-level instrumentation during normal operations. Any dissolved noncondensible gases inside these water columns may come out of solution during rapid depressurization events and displace water from the reference leg piping, resulting in a false high level. Significant errors in water-level indication are not expected to occur until the reactor pressure vessel (RPV) pressure has dropped below [approximately]450 psig. These water level errors may cause a delay or failure in emergency core cooling system (ECCS) actuation. The RPV water level is monitored using the pressure of a water column having amore » varying height (reactor water level) that is compared to the pressure of a water column maintained at a constant height (reference level). The reference legs have small-diameter pipes with varying lengths that provide a constant head of water and are located outside the drywell. The amount of noncondensible gases dissolved in each reference leg is very dependent on the amount of leakage from the reference leg and its geometry and interaction of the reactor coolant system with the containment, i.e., torus or suppression pool, and reactor building. If a rapid depressurization causes an erroneously high water level, preventing automatic ECCS actuation, it becomes important to determine if there would be other adequate indications for operator response. In the postulated inadvertent opening of all seven automatic depressurization system (ADS) valves, the ECCS signal on high drywell pressure would be circumvented because the ADS valves discharge directly into the suppression pool. A best-estimate analysis of such an inadvertent opening of all ADS valves would have to consider the thermal-hydraulic coupling between the pool, drywell, reactor building, and RPV.« less
The Impact of Different Environmental Conditions on Cognitive Function: A Focused Review
Taylor, Lee; Watkins, Samuel L.; Marshall, Hannah; Dascombe, Ben J.; Foster, Josh
2016-01-01
Cognitive function defines performance in objective tasks that require conscious mental effort. Extreme environments, namely heat, hypoxia, and cold can all alter human cognitive function due to a variety of psychological and/or biological processes. The aims of this Focused Review were to discuss; (1) the current state of knowledge on the effects of heat, hypoxic and cold stress on cognitive function, (2) the potential mechanisms underpinning these alterations, and (3) plausible interventions that may maintain cognitive function upon exposure to each of these environmental stressors. The available evidence suggests that the effects of heat, hypoxia, and cold stress on cognitive function are both task and severity dependent. Complex tasks are particularly vulnerable to extreme heat stress, whereas both simple and complex task performance appear to be vulnerable at even at moderate altitudes. Cold stress also appears to negatively impact both simple and complex task performance, however, the research in this area is sparse in comparison to heat and hypoxia. In summary, this focused review provides updated knowledge regarding the effects of extreme environmental stressors on cognitive function and their biological underpinnings. Tyrosine supplementation may help individuals maintain cognitive function in very hot, hypoxic, and/or cold conditions. However, more research is needed to clarify these and other postulated interventions. PMID:26779029
The Next Generation of Cold Immersion Dry Suit Design Evolution for Hypothermia Prevention
NASA Technical Reports Server (NTRS)
Galofaro, Joel
2013-01-01
This new utility patent is an active design that relies on the lung's role as an organic heat exchanger for providing deep body core heating of air. It is based on the fact that the greatest heat loss mechanism for an insulated human body immersed in a cold water environment is due to heat loss through respiration. This innovation successfully merges two existing technologies (cold immersion suit and existing valve technologies) to produce a new product that helps prevent against the onset of hypothermia at sea. During normal operations, a human maintains an approximate body temperature of [98.6 F (37 C)]. A mechanism was developed to recover the warm temperature from the body and reticulate it in a survival suit. The primary intention is to develop an encompassing systems design that can both easily and cost effectively be integrated in all existing currently manufactured cold water survival suits, and as such, it should be noted that the cold water immersion suit is only used as a framework or tool for laying out the required design elements. At the heart of the suit is the Warm Air Recovery (WAR) system, which relies on a single, large Main Purge Valve (MPV) and secondary Purge Valves (PV) to operate. The main purge valve has a thin membrane, which is normally closed, and acts as a one-way check valve. When warm air is expelled from the lungs, it causes the main purge valve to open. Air forced from the MPV is dumped directly into the suit, thereby providing warmth to the torso, legs, and arms. A slight positive over-pressure in the suit causes warm waste air (or water if the suit is punctured) to be safely vented into the sea through large PVs located at the bottom of each arm and leg. The secondary purge valves act to prevent the buildup of large concentrations of CO2 gas and help guard against asphyxia. It is noted that the MPV causes the inhalation and exhalation cycles to be completely isolated from one another in the current suit design.
Natural circulation in a liquid metal one-dimensional loop
NASA Astrophysics Data System (ADS)
Tarantino, M.; De Grandis, S.; Benamati, G.; Oriolo, F.
2008-06-01
A wide use of pure lead, as well as its alloys (such as lead-bismuth, lead-lithium), is foreseen in several nuclear-related fields: it is studied as coolant in critical and sub-critical nuclear reactors, as spallation target for neutron generation in several applications and for tritium generation in fusion systems. In this framework, a new facility named NAtural CIrculation Experiment (NACIE), has been designed at ENEA-Brasimone Research Centre. NACIE is a rectangular loop, made by stainless steel pipes. It consists mainly of a cold and hot leg and an expansion tank installed on the top of the loop. A fuel bundle simulator, made by three electrical heaters placed in a triangular lattice, is located in the lower part of the cold leg, while a tube in tube heat exchanger is installed in the upper part of the hot leg. The adopted secondary fluid is THT oil, while the foreseen primary fluid for the tests is lead-bismuth in eutectic composition (LBE). The aim of the facility is to carry out experimental tests of natural circulation and collect data on the heat transfer coefficient (HTC) for heavy liquid metal flowing through rod bundles. The paper is focused on the preliminary estimation of the LBE flow rate along the loop. An analytical methodology has been applied, solving the continuity, momentum and energy transport equations under appropriate hypothesis. Moreover numerical simulations have been performed. The FLUENT 6.2 CFD code has been utilized for the numerical simulations. The main results carried out from the pre-tests simulations are illustrated in the paper, and a comparison with the theoretical estimations is done.
NASA Astrophysics Data System (ADS)
Macdonald, Kenneth C.
Forty-foot, storm-swept seas, Spitzbergen polar bears roaming vast expanses of Arctic ice, furtive exchanges of forbidden manuscripts in Cold War Moscow, the New York city fashion scene, diving in mini-subs to the sea floor hot srings, life with the astronauts, romance and heartbreak, and invading the last bastions of male exclusivity: all are present in this fast-moving, non-fiction account of one woman' fascinating adventures in the world of marine geology and oceanography.
Three-Dimensional Finite-Element Simulation for a Thermoelectric Generator Module
NASA Astrophysics Data System (ADS)
Hu, Xiaokai; Takazawa, Hiroyuki; Nagase, Kazuo; Ohta, Michihiro; Yamamoto, Atsushi
2015-10-01
A three-dimensional closed-circuit numerical model of a thermoelectric generator (TEG) module has been constructed with COMSOL® Multiphysics to verify a module test system. The Seebeck, Peltier, and Thomson effects and Joule heating are included in the thermoelectric conversion model. The TEG model is employed to simulate the operation of a 16-leg TEG module based on bismuth telluride with temperature-dependent material properties. The module is mounted on a test platform, and simulated by combining the heat conduction process and thermoelectric conversion process. Simulation results are obtained for the terminal voltage, output power, heat flow, and efficiency as functions of the electric current; the results are compared with measurement data. The Joule and Thomson heats in all the thermoelectric legs, as functions of the electric current, are calculated by finite-element volume integration over the entire legs. The Peltier heat being pumped at the hot side and released at the cold side of the module are also presented in relation to the electric current. The energy balance relations between heat and electricity are verified to support the simulation.
SIIOS in Alaska - Testing an `In-Vault' Option for a Europa Lander Seismometer.
NASA Astrophysics Data System (ADS)
Bray, V. J.; Weber, R. C.; DellaGiustina, D. N.; Bailey, H.; Schmerr, N. C.; Pettit, E. C.; Dahl, P.; Albert, D.; Avenson, B.; Byrne, S.; Siegler, M.; Bland, M. T.; Patterson, G. W.; Selznick, S.
2017-12-01
The surface environment of Europa within the radiation-heavy jovian system, poses extreme technical challenges for potential landed missions. The need for radiation shielding and protection from the cold requires instruments to be housed within a thermally insulated and radiation protected `vault'. Unfortunately, this is non-ideal for seismometers as instrument-to-surface coupling is an important factor in the quality of returned data. Delivering a seismic package to an icy world would therefore benefit from the development of a cold-tolerant, radiation-hardened sensor that can survive outside of a protective vault. If such an instrument package were not technologically mature enough, or if lander safety considerations prevent deployment on lander legs, an in-vault location is still a viable option. For such a case, a better understanding of the transmission of seismic signals received through the lander legs is necessary for interpretation of the received signals. The performance, mass, and volume of the `Seismometer to investigate ice and ocean structure' (SIIOS) already meet or exceed flight requirements identified in lander studies for the icy moon Europa. We are testing this flight-candidate in several configurations around and within a lander mock-up, assuming a 1x1 meter vault with extended legs. We compare the received signals from a SIIOS device on the ice with those received by an identical sensor directly above it in the `vault'. We also compare the data from these single-point receivers to that received by two short base-line arrays - A 4-point "in-vault" array and another 4-point array arranged at the ice surface at the base of the lander legs. Our field-testing is performed at Gulkana Glacier, Alaska. The summer melt season provides kilometer-scale regions of coexisting ice, water, and silicate material, thereby providing seismic contrasts analogous to the ice-water layers and possible sub-surface lakes expected at Europa. We demonstrate the sensitivity of SIIOS to detect a variety of passive and active sources from both on-ice and lander-mounted locations, and compare the accuracy of ice-water boundary identification and event location from each configuration.
Contrast Therapy and Intramuscular Temperature in the Human Leg
Myrer, J. William; Draper, David O.; Durrant, Earlene
1994-01-01
Contrast therapy, although having a long history of use in sports medicine and physical therapy, remains insufficiently researched. We investigated the thermal effects of contrast therapy on intramuscular temperature. We randomly assigned 28 college students to either a control or a contrast group, eight women and six men per group. We shaved and cleansed a 4- × 4-cm area of skin over the right medial calf and inserted a microprobe to a depth of 1 cm below the skin and subcutaneous fat in the center of the gastrocnemius. Each control subject immersed the treatment leg in a hot whirlpool (40.6°C) for 20 minutes. Each contrast subject first immersed the treatment leg in a hot whirlpool (40.6°C) for 4 minutes then into a cold whirlpool (15.6°C) for 1 minute. Contrast subjects repeated this sequence three additional times. We recorded intramuscular temperatures every 30 seconds over the entire treatment time for both groups. The control group had a temperature increase of 2.83 ± 1.14°C over the 20-minute treatment. The contrast group temperature increased 0.39 ± 0.46°C from baseline to the end of the treatment. The largest temperature change from the end of one contrast immersion to the end of the next was only 0.15 ± 0.10°C. None of the differences between the end of one immersion to the end of the next were significant. Conversely, all differences between the same time periods in the control group had significant temperature increases. Apparently contrast therapy, as studied, is incapable of producing any significant physiological effect on the intramuscular tissue temperature 1 cm below the skin and subcutaneous tissue. We recommend that further research be done to examine the effects of longer periods in both the hot and cold environments on the intramuscular temperature of the human leg. Further investigation of intra-articular or peri-articular temperature change produced by contrast therapy should also be undertaken. ImagesFig 1. PMID:16558294
2014-09-30
for Analysis of Convective Mass Flux Parameterizations Using DYNAMO Direct Observations R. Michael Hardesty CIRES/University of Colorado/NOAA 325...the RV-Revell during legs 2 & 3 of the DYNAMO experiement to help characterize vertical transport through the boundary layer and to build statistics...obtained during DYNAMO , and to investigate whether cold pools that emanate from convection organize the interplay between humidity and convection and
Performance Test Results of a Skutterudite-Based Unicouple with a Metallic Coating
NASA Astrophysics Data System (ADS)
Saber, Hamed H.; El-Genk, Mohamed S.; Caillat, Thierry
2005-02-01
A performance test of a Skutterudite-based unicouple (MAY-04) with a metallic coating to suppress the sublimation of antimony from the legs near the hot junction is performed in vacuum (˜ 9 ×10-7 torr) for ˜ 2,000 hours at hot and cold junction temperatures of 892.1 ± 11.9 K and 316.1 ± 5.5 K, respectively. The p-leg is made of CeFe3.5Co0.5Sb12 and the n-leg is made of CoSb3. Presented are the measured voltage-current characteristics, electrical power, open-circuit voltage, and the Seebeck coefficients of the legs as functions of cumulative test time. Also presented is the estimate of the conversion efficiency, ˜ 96 hrs after the start of test. To demonstrate the effectiveness of the metallic coating, the measurements for MAY-04 are compared with those of two uncoated unicouples of the same leg materials (MAR-03 and JUN-03), which had been tested earlier. The cross-sectional areas of the legs in MAY-04 are larger than those in MAR-03 and JUN-03, tested in argon cover gas at ˜ 0.051-0.068 MPa for 450 and 1200 hours, respectively. The open circuit voltage, Voc (204 mV) of MAY-04 at Beginning-Of-Test (BOT) is almost the same as that of MAR-03, but higher than that of JUN-03 (˜180 mV). Although the argon gas effectively decreased antimony loss from legs of MAR-03 and JUN-03, marked degradations in performance occurred with time in these tests. Conversely, the metallic coating in MAY-04 effectively reduced the performance degradation with cumulative test time. The estimated peak efficiency of MAY-04, shortly after BOT (10.65%) is only ˜ 0.37 percentage point lower than the theoretical value, assuming zero side heat losses and zero contact resistance per leg. The peak power of MAY-04 decreased by only ˜12%, from its BOT value of ˜1.6 We to ˜1.4 We after ˜2,000 of cumulative testing.
Pathophysiology of Non-Freezing Cold Injury
1989-07-01
the leg. Salicylic acid was injected through the femoral vein at the end of some experiments to assay hydroxy radical (OH*). Our results demonstrated...pH 4.5); 50 J1 of 70% perchloric acid was then added to the mixtur,". The resultant mixture was degassed and filtered through a Rainin Nylon-66...consisting of a Model 510 pump and a Model 460 electrochemical detector. The hydroxylated products of salicylic acid were eluted with buffer (degassed and
Advanced Soldier Thermoelectric Power System for Power Generation from Battlefield Heat Sources
2010-09-01
Figure 6.10 TE Module with Microtherm Added Around & Between Legs ............................................................... 57 Figure 6.11 Short... Microtherm ® insulation, 2.6 (W) of heater power was required to maintain a temperature of 400 ºC. This is an indication of the losses in the system...side of the module to the cold plate. Pour in Microtherm to insulate the module. Make sure to clean all insulation from the hot side electrodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Subhasish; Soppet, William; Majumdar, Saurin
This report provides an update on an assessment of environmentally assisted fatigue for light water reactor components under extended service conditions. This report is a deliverable in April 2015 under the work package for environmentally assisted fatigue under DOE's Light Water Reactor Sustainability program. In this report, updates are discussed related to a system level preliminary finite element model of a two-loop pressurized water reactor (PWR). Based on this model, system-level heat transfer analysis and subsequent thermal-mechanical stress analysis were performed for typical design-basis thermal-mechanical fatigue cycles. The in-air fatigue lives of components, such as the hot and cold legs,more » were estimated on the basis of stress analysis results, ASME in-air fatigue life estimation criteria, and fatigue design curves. Furthermore, environmental correction factors and associated PWR environment fatigue lives for the hot and cold legs were estimated by using estimated stress and strain histories and the approach described in NUREG-6909. The discussed models and results are very preliminary. Further advancement of the discussed model is required for more accurate life prediction of reactor components. This report only presents the work related to finite element modelling activities. However, in between multiple tensile and fatigue tests were conducted. The related experimental results will be presented in the year-end report.« less
Critical Protection Item classification for a waste processing facility at Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ades, M.J.; Garrett, R.J.
1993-10-01
This paper describes the methodology for Critical Protection Item (CPI) classification and its application to the Structures, Systems and Components (SSC) of a waste processing facility at the Savannah River Site (SRS). The WSRC methodology for CPI classification includes the evaluation of the radiological and non-radiological consequences resulting from postulated accidents at the waste processing facility and comparison of these consequences with allowable limits. The types of accidents considered include explosions and fire in the facility and postulated accidents due to natural phenomena, including earthquakes, tornadoes, and high velocity straight winds. The radiological analysis results indicate that CPIs are notmore » required at the waste processing facility to mitigate the consequences of radiological release. The non-radiological analysis, however, shows that the Waste Storage Tank (WST) and the dike spill containment structures around the formic acid tanks in the cold chemical feed area and waste treatment area of the facility should be identified as CPIs. Accident mitigation options are provided and discussed.« less
Physiological changes in women during exercise in cold environments
NASA Astrophysics Data System (ADS)
Murray, S. J.; Shephard, R. J.; Radomski, M. W. M.
1986-12-01
Both the stress of exercise and the stress of a cold environment have been shown to increase the mobilization and utilization of body fat, thereby reducing body fat stores. Much of the research has been done on either rats or male human subjects. The purpose of this research was to show the physiological changes which occur to young, relatively obese, women who exercised during five consecutive days, for 200 min per day, in each of three environmental, chamber conditions: (1) warm-warm (WW), +15‡C; (2) cold-cold (CC), -20‡C; and (3) cold-warm (CW), -20‡C ambient temperature, with +18‡C air pumped to face masks for warmed air breathing. Oxygen cost of exercise, respiratory quotients, energy intake and utilization, and body composition changes were measured before, during, and after each environmental condition. While the respiratory quotients and the skinfold measurements decreased in the colder conditions, the underwater weighing determined percentage body fat did not show the same decrement as the skinfold measures, indicating a possible translocation of body fat from the subcutaneous depots to the deep body fat depots. Body mass loss was significant (P<0.05) only in the WW condition. Thermogenesis would have been centred in the skeletal muscle and liver during the CW condition; however, with facial and upper airway cooling in the CC condition; brown adipose tissue (BAT) hypertrophy may be postulated at this more intense level of cold stress. Due to a greater stability of depot fat in the female, a longer cold exposure would be required to observe the fully developed BAT thermogenesis which would follow after the consequences of fat translocation which we have documented.
Controlled parity switch of persistent currents in quantum ladders
NASA Astrophysics Data System (ADS)
Filippone, Michele; Bardyn, Charles-Edouard; Giamarchi, Thierry
2018-05-01
We investigate the behavior of persistent currents for a fixed number of noninteracting fermions in a periodic quantum ladder threaded by Aharonov-Bohm and transverse magnetic fluxes Φ and χ . We show that the coupling between ladder legs provides a way to effectively change the ground-state fermion-number parity, by varying χ . Specifically, we demonstrate that varying χ by 2 π (one flux quantum) leads to an apparent fermion-number parity switch. We find that persistent currents exhibit a robust 4 π periodicity as a function of χ , despite the fact that χ →χ +2 π leads to modifications of order 1 /N of the energy spectrum, where N is the number of sites in each ladder leg. We show that these parity-switch and 4 π periodicity effects are robust with respect to temperature and disorder, and outline potential physical realizations using cold atomic gases and photonic lattices, for bosonic analogs of the effects.
Recollections of their fathers by homosexual and heterosexual men.
Phelan, J E
1996-12-01
A nonrandom, nonclinical t-test comparison study of 30 homosexual and 30 heterosexual men was conducted to describe their memories of their fathers' behaviors toward them. Previous studies had identified the "classical pattern," that is, the fathers of homosexual men were considered cold, hostile, and distant. Those studies were sparked by Freudian theory which postulated the same. Therefore, a brief revisitation has been conducted. Again, the findings supported the earlier, that is, the homosexual men recalled their fathers as more rejecting and less loving than the heterosexual men.
A stratocumulus thermodynamic analysis: July 5 case study
NASA Technical Reports Server (NTRS)
Austin, Philip
1990-01-01
On July 5 (NCAR Electra flight 4, Mission 186-G) the Electra flew a single aircraft mission which consisted of cross and along-wind legs at 6 different altitudes between 10:43 to 16:00 PDT (17:43 to 23:00 GMT). The leg length was kept short (8 to 10 minutes) to permit maximum vertical resolution, and there were 8 soundings. Observer notes report a thin, solid stratocumulus cloud deck which gradually became more broken in the afternoon. Winds were from the north at 10 to 13/ms throughout the night. Sea surface temperature measurements and conservative variable analyses for several of the July 5 legs are presented. These results are preliminary to a study of the thermodynamic budget on July 5; they indicate that: the sea surface temperature dropped more than 1 K (from 17.3 to 15.9 C) over the course of the flight (18:01 and at 21:51 GMT); mixing lines for each of the horizontal subcloud legs show the effect of a strong north-south gradient in SST; and there is a clear demarcation over a transition of 5 to 10 km between air to the south and cooler, moister air to the north. The FSSP measurements indicate there are small clouds/scud 250 m below cloud base on the cold northern side of this transition. The transition is seen in the saturation point diagrams at 984, 959, and 946 mb. There is no corresponding change in the horizontal wind across the transition regions.
In Situ Bioremediation of Chlorinated Solvent Source Areas with Enhanced Mass Transfer
2008-09-01
immerse in cold water. Do not apply ointment , grease or Vaseline. Cover burns with thick, dry sterile dressings. Keep burned feet or legs elevated...about six to eight barrels per month of waste TCE and POL may have been disposed. These materials were also used to aid in burning other wastes...These consist of man-made fill in the trench areas and include debris and burned material. These materials typically extend to less than 12 ft bgs
Garrido-Allepuz, Carlos; Haro, Endika; González-Lamuño, Domingo; Martínez-Frías, María Luisa; Bertocchini, Federica; Ros, Maria A
2011-05-01
Sirenomelia, also known as sirenomelia sequence, is a severe malformation of the lower body characterized by fusion of the legs and a variable combination of visceral abnormalities. The causes of this malformation remain unknown, although the discovery that it can have a genetic basis in mice represents an important step towards the understanding of its pathogenesis. Sirenomelia occurs in mice lacking Cyp26a1, an enzyme that degrades retinoic acid (RA), and in mice that develop with reduced bone morphogenetic protein (Bmp) signaling in the caudal embryonic region. The phenotypes of these mutant mice suggest that sirenomelia in humans is associated with an excess of RA signaling and a deficit in Bmp signaling in the caudal body. Clinical studies of sirenomelia have given rise to two main pathogenic hypotheses. The first hypothesis, based on the aberrant abdominal and umbilical vascular pattern of affected individuals, postulates a primary vascular defect that leaves the caudal part of the embryo hypoperfused. The second hypothesis, based on the overall malformation of the caudal body, postulates a primary defect in the generation of the mesoderm. This review gathers experimental and clinical information on sirenomelia together with the necessary background to understand how deviations from normal development of the caudal part of the embryo might lead to this multisystemic malformation.
Micro-Thermoelectric Generation Modules Fabricated with Low-Cost Mechanical Machining Processes
NASA Astrophysics Data System (ADS)
Liu, Dawei; Jin, A. J.; Peng, Wenbo; Li, Qiming; Gao, Hu; Zhu, Lianjun; Li, Fu; Zhu, Zhixiang
2017-05-01
Micro/small-scale thermoelectric generation modules are able to produce continuous, noise-free and reliable electricity power using low temperature differences that widely exist in nature or industry. These advantages bring them great application prospects in the fields of remote monitoring, microelectronics/micro-electromechanical systems (MEMS), medical apparatus and smart management system, which often require a power source free of maintenance and vibration. In this work, a prototypical thermoelectric module (12 mm × 12 mm × 0.8 mm) with 15 pairs of micro-scale thermoelectric legs (0.2 mm in width and 0.6 mm in height for each leg) is fabricated using a low-cost mechanical machining process. In this process, cutting and polishing are the main methods for the preparation of thermoelectric pairs from commercial polycrystalline materials and for the fabrication of electrode patterns. The as-fabricated module is tested for its power generation properties with the hot side heated by an electrical heater and the cold side by cold air. With the heater temperature of 375 K, the thermoelectric potential is about 9.1 mV, the short circuit current is about 14.5 mA, and the maximum output power is about 32.8 μW. The finite element method is applied to analyze the heat transfer of the module during our test. The temperature difference and heat flux are simulated, according to which the output powers at different temperatures are calculated, and the result is relatively consistent compared to the test results.
The effect of fluid overload on sleep apnoea severity in haemodialysis patients.
Lyons, Owen D; Inami, Toru; Perger, Elisa; Yadollahi, Azadeh; Chan, Christopher T; Bradley, T Douglas
2017-04-01
As in heart failure, obstructive and central sleep apnoea (OSA and CSA, respectively) are common in end-stage renal disease. Fluid overload characterises end-stage renal disease and heart failure, and in heart failure plays a role in the pathogenesis of OSA and CSA. We postulated that in end-stage renal disease patients, those with sleep apnoea would have greater fluid volume overload than those without.End-stage renal disease patients on thrice-weekly haemodialysis underwent overnight polysomnography on a nondialysis day to determine their apnoea-hypopnoea index (AHI). Extracellular fluid volume of the total body, neck, thorax and right leg were measured using bioelectrical impedance.28 patients had an AHI ≥15 (sleep apnoea group; OSA:CSA 21:7) and 12 had an AHI <15 (no sleep apnoea group). Total body extracellular fluid volume was 2.6 L greater in the sleep apnoea group than in the no sleep apnoea group (p=0.006). Neck, thorax, and leg fluid volumes were also greater in the sleep apnoea than the no sleep apnoea group (p<0.05), despite no difference in body mass index (p=0.165).These findings support a role for fluid overload in the pathogenesis of both OSA and CSA in end-stage renal disease. Copyright ©ERS 2017.
Pereira de Godoy, José Maria; de Fátima Guerreiro Godoy, Maria
2018-01-01
The case of a 54-year-old cardiac patient is reported, who was admitted to hospital with a complaint of sudden pain in the legs associated with edema, paresthesia, and coldness. Arterial embolism of the lower limbs was diagnosed and the patient was submitted to bilateral embolectomy. The patient evolved with a burning sensation, hypersensitivity in the right leg, swelling, and difficulty bending and stretching the sole of the foot and the knee. A physical examination detected edema and increased tension in the anterior, lateral, and posterior compartments. Treatment using intermittent massage of the leg during the evaluation of the patient was chosen in an attempt to stimulate lymphatic and venous drainage. After a few minutes of stimulation, there was significant improvement in the pain and edema. In 40 minutes, there was total reduction of the pain in the posterior and lateral compartments and improvement of over 50% in the anterior compartment. After this, the patient started to bend the knee without pain and bend the sole of the foot with slight pain. On the following day, the patient was walking around the hospital ward without difficulty. It seems that intermittent massage is a therapeutic option in selected cases of compartment syndrome.
NASA Technical Reports Server (NTRS)
Choi, Gene; Jones, David L.; Morris, James; Parham, Martin; Stephens, Jim; Yancey, Gregg
1987-01-01
A mechanical design team was formed to design a foot for the lunar utility vehicle SKITTER. The primary design was constrained to be a ski pole design compatible with the existing femur-tibia design legs. The lunar environment had several important effects on the foot design. Three materials were investigated for the SKITTER foot: aluminum alloys, cold worked stainless steel alloys, and titanium alloys. Thin film coatings were investigated as a method of wear reduction for the foot. The performance of the foot is dependent on the action of the legs. The range of motion for the legs was determined to be vertical to 15 degrees above horizontal. An impact analysis was performed for the foot movement, but the results were determined to be inconclusive due to unknown soil parameters. The initial foot design configuration consisted of an annulus attached to the pointed pole. The annulus was designed to prevent excess sinkage. Later designs call for a conical shaped foot with a disk at the point of the tibia attachment. The conical design was analyzed for strength and deflection by two different approaches. A deformable body analysis was performed for the foot under crane load in crane position, and also under actuator load in the vertical position. In both cases, the deflection of the foot was insignificant and the stresses well below the strength of the titanium alloy.
Magnetization of lower oceanic crust and upper mantle
NASA Astrophysics Data System (ADS)
Kikawa, E.
2004-05-01
The location of the magnetized rocks of the oceanic crust that are responsible for sea-floor spreading magnetic anomalies has been a long-standing problem in geophysics. The recognition of these anomalies was a key stone in the development of the theory of plate tectonics. Our present concept of oceanic crustal magnetization is much more complex than the original, uniformly magnetized model of Vine-Matthews-Morley Hypothesis. Magnetic inversion studies indicated that the upper oceanic extrusive layer (Layer 2A of 0.5km thick) was the only magnetic layer and that it was not necessary to postulate any contribution from deeper parts of oceanic crust. Direct measurements of the magnetic properties of the rocks recovered from the sea floor, however, have shown that the magnetization of Layer 2A, together with the observations that this layer could record geomagnetic field reversals within a vertical section, is insufficient to give the required size of observed magnetic anomalies and that some contribution from lower intrusive rocks is necessary. Magnetization of oceanic intrusive rocks were observed to be reasonably high enough to contribute to sea-floor spreading magnetic anomalies, but were considered somewhat equivocal until late 1980Os, in part because studies had been conducted on unoriented dredged and ophiolite samples and on intermittent DSDP/ODP cores. Since ODP Leg 118 that cored and recovered continuous 500m of oceanic intrusive layer at Site 735B, Southwest Indian Ridge with an extremely high recovery of 87 percent, there have been several ODP Legs (legs 147, 153, 176, 179 and 209) that were devoted to drilling gabbroic rocks and peridotites. In terms of the magnetization intensities, all of the results obtained from these ODP Legs were supportive of the model that a significant contribution must come from gabbros and peridotites and the source of the lineated magnetic anomalies must reside in most of the oceanic crust as well as crust-mantle boundary. However, it would be wise to note that similar to upper extrusive layer, geomagnetic field reversals were observed for Leg 153 gabbros and that process of magnetization acquisition of mantle peridotites still remains unclear, though we believe mantle peridotites acquire CRM with the formation of magnetite during the process of serpentinization near the ridge axis.
[Alarm symptoms of meningitis in children with fever].
Geurts, Dorien H F; Moll, Henriette A
2011-01-01
A 15-year-old girl presented with fever and pain in her legs. A viral infection was suspected, but within 24 hours she became confused and developed meningeal signs, based on which she was diagnosed as having meningitis. Within a few hours a 6-month-old boy developed fever, a grey colour, bulging fontanel, cold hands and feet, and was groaning. He too appeared to have meningitis. It is important to recognize this serious infection in children with fever, since delay of diagnosis and treatment may result in serious complications. Recognition is difficult because of non-specific symptoms on presentation and a lack of alarm symptoms early in the course of the disease. Alarm symptoms of serious infection in children are cyanosis, rapid breathing, decreased capillary refill, petechial rash, meningeal signs, leg pain and decreased consciousness. If serious infection is uncertain in a child with fever, parents should be advised on the potential course of the disease, the alarm symptoms and the need to seek medical help in time.
Lunar volatiles: balancing science and resource development
NASA Astrophysics Data System (ADS)
Crider, Dana
In the context of human exploration of the moon, the volatiles postulated to exist at the lunar poles have value as resources as well as scientific significance. Once sustained human operations commence on the moon, society will move from a paradigm in which examination of planetary materials has been unconstrained to one where use of those materials will support habitability and further exploration. A framework for the scientific investigation of lunar volatiles that allows for eventual economic exploitation can guide both activities and resolve the conflicts that will inevitably develop if the postulated lunar volatiles prove to be both extant and accessible. Scientific constraints on the framework include characterization at both poles of the isotopes, elements, and molecules in the volatiles, their relative and absolute abundances, and their horizontal and vertical distribution. A subset of this data is necessary in order to assess, develop, and initiate resource exploitation. In addition, the scientific record of volatiles in the cold traps can be contaminated by the cold-trapping of migrating volatiles released from operations elsewhere on the moon even if the indigenous, cold-trapped volatiles are not utilized. Possible decision points defining the transition from science-dominated to exploitation-dominated use include technology limits in the 70K environment, evolving science priorities (funding), and the resolution of major science issues. Inputs to policy development include any North vs. South Pole differences in volatile characteristics and the suitability of the volatiles to enable further scientific exploration of the moon. In the absence of national sovereignty on the moon, enforcement of any framework is an open question, particularly if science and commercial interests are in competition. The framework, processes, and precedent set by how we as a society choose to handle the scientific bounty and resource promise of lunar volatiles may eventually apply to Mars and near-earth asteroids. We believe there are useful lessons to be learned from the terrestrial experience with protected areas such as national parks, wilderness areas, and archeological sites. International agreements such as the Antarctic Treaty (in force since 1961), the Outer Space Treaty (1967), and the Moon Treaty (1979) carry relevant lessons as well.
Preliminary posttest analysis of LOFT loss-of-coolant experiment L2-2
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, J.R.; Grush, W.H.; Keeler, C.D.
A preliminary posttest analysis of Loss-of-Coolant Experiment (LOCE) L2-2, which was conducted in the Loss-of-Fluid Test (LOFT) facility, was performed to gain an understanding of the cause of the disparity between predicted and measured fuel rod cladding temperature responses in the LOFT core. LOCE L2-2 is the first experiment in the LOFT Power Ascension Series L2 (first series of LOFT nuclear experiments), which was designed to investigate the response of the LOFT nuclear core to the blowdown, refill, and reflood transients during LOCEs conducted at gradually increasing power levels. LOCE L2-2 was conducted at 50% power (25 MW, 26.38 kW/m).more » Results show that a core-wide rewet occurred early in the transient (during blowdown starting at about 7 s after rupture) which was not calculated in the pretest prediction analysis. This early core-wide rewet resulted in the peak fuel rod cladding temperatures being lower (by a mean value of 166/sup 0/K for 24 thermocouples) than had been calculated. This preliminary posttest analysis was concerned solely with determining why the early core-wide rewet was not predicted by the RELAP4/MOD6 pretest analysis and be no means is it a complete posttest analysis of LOCE L2-2 results. However, during this analysis, several errors made in the prettest analysis were found, and their impact on the predicted results is assessed. Three factors were postulated to have caused the disparity between predicted and measured fuel rod cladding temperatures for LOCE L2-2: (a) the initial fuel rod stored energy, (b) the heat transfer surface, and (c) the hydraulics calculation. These factors were examined and are discussed in this report. It was determined that core hydraulics, as influenced by the calculation of broken loop cold leg break flow, was the major factor causing the disparity.« less
Phenylethylamine N-methylation by human brain preparations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosnaim, A.D.; Callaghan, O.H.; Wolf, M.E.
Alterations in the brain metabolism of biogenic amines has been postulated to play a role in the pathophysiology of several psychiatric disorders. There is some evidence suggesting schizogenic properties for some abnormal neuroamine methylated derivatives. The authors now report that postmortem human brain preparations, obtained from the putamen and thalamus, convert phenylethylamine (PEA) to its behaviorally active derivative N-methyl PEA, a reaction which is carried out by the 100,000 xg supernatant (in presence of 1 x 10 /sup -5/M pargyline) and enhanced by the addition of NADPH. PEA N-methylation occurred in schizophrenics as well as in sex and age matchedmore » controls. The formation of increased amounts of (/sup 3/H-) or (/sup 14/C-) N-methyl PEA when incubating either cold amine and /sup 3/H-SAM or 1-/sup 14/C PEA and cold SAM, respectively, indicates that SAM is a methyl group donor in this reaction. They will discuss the physiological and pharmacological implications of these results.« less
NASA Astrophysics Data System (ADS)
Xiao, Heng; Gou, Xiaolong; Yang, Suwen
2011-05-01
Thermoelectric (TE) power generation technology, due to its several advantages, is becoming a noteworthy research direction. Many researchers conduct their performance analysis and optimization of TE devices and related applications based on the generalized thermoelectric energy balance equations. These generalized TE equations involve the internal irreversibility of Joule heating inside the thermoelectric device and heat leakage through the thermoelectric couple leg. However, it is assumed that the thermoelectric generator (TEG) is thermally isolated from the surroundings except for the heat flows at the cold and hot junctions. Since the thermoelectric generator is a multi-element device in practice, being composed of many fundamental TE couple legs, the effect of heat transfer between the TE couple leg and the ambient environment is not negligible. In this paper, based on basic theories of thermoelectric power generation and thermal science, detailed modeling of a thermoelectric generator taking account of the phenomenon of energy loss from the TE couple leg is reported. The revised generalized thermoelectric energy balance equations considering the effect of heat transfer between the TE couple leg and the ambient environment have been derived. Furthermore, characteristics of a multi-element thermoelectric generator with irreversibility have been investigated on the basis of the new derived TE equations. In the present investigation, second-law-based thermodynamic analysis (exergy analysis) has been applied to the irreversible heat transfer process in particular. It is found that the existence of the irreversible heat convection process causes a large loss of heat exergy in the TEG system, and using thermoelectric generators for low-grade waste heat recovery has promising potential. The results of irreversibility analysis, especially irreversible effects on generator system performance, based on the system model established in detail have guiding significance for the development and application of thermoelectric generators, particularly for the design and optimization of TE modules.
NASA Astrophysics Data System (ADS)
Baker, Chad; Vuppuluri, Prem; Shi, Li; Hall, Matthew
2012-06-01
The performance and operating characteristics of a hypothetical thermoelectric generator system designed to extract waste heat from the exhaust of a medium-duty turbocharged diesel engine were modeled. The finite-difference model consisted of two integrated submodels: a heat exchanger model and a thermoelectric device model. The heat exchanger model specified a rectangular cross-sectional geometry with liquid coolant on the cold side, and accounted for the difference between the heat transfer rate from the exhaust and that to the coolant. With the spatial variation of the thermoelectric properties accounted for, the thermoelectric device model calculated the hot-side and cold-side heat flux for the temperature boundary conditions given for the thermoelectric elements, iterating until temperature and heat flux boundary conditions satisfied the convection conditions for both exhaust and coolant, and heat transfer in the thermoelectric device. A downhill simplex method was used to optimize the parameters that affected the electrical power output, including the thermoelectric leg height, thermoelectric n-type to p-type leg area ratio, thermoelectric leg area to void area ratio, load electrical resistance, exhaust duct height, coolant duct height, fin spacing in the exhaust duct, location in the engine exhaust system, and number of flow paths within the constrained package volume. The calculation results showed that the configuration with 32 straight fins was optimal across the 30-cm-wide duct for the case of a single duct with total height of 5.5 cm. In addition, three counterflow parallel ducts or flow paths were found to be an optimum number for the given size constraint of 5.5 cm total height, and parallel ducts with counterflow were a better configuration than serpentine flow. Based on the reported thermoelectric properties of MnSi1.75 and Mg2Si0.5Sn0.5, the maximum net electrical power achieved for the three parallel flow paths in a counterflow arrangement was 1.06 kW for package volume of 16.5 L and exhaust flow enthalpy flux of 122 kW.
An international trial of quantitative PCR for monitoring Legionella in artificial water systems.
Lee, J V; Lai, S; Exner, M; Lenz, J; Gaia, V; Casati, S; Hartemann, P; Lück, C; Pangon, B; Ricci, M L; Scaturro, M; Fontana, S; Sabria, M; Sánchez, I; Assaf, S; Surman-Lee, S
2011-04-01
To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae. Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were monitored over ≥10 weeks. For cooling towers (232 samples), there was a significant difference between the log mean difference between qPCR (GU l(-1) ) and culture (CFU l(-1) ) for Legionella pneumophila (0·71) and for Legionella spp. (2·03). In hot and cold water (506 samples), the differences were less, 0·62 for Leg. pneumophila and 1·05 for Legionella spp. Results for individual systems depended on the nature of the system and its treatment. In cooling towers, Legionella spp. GU l(-1) always exceeded CFU l(-1) , and usually Legionella spp. were detected by qPCR when absent by culture. The pattern of results by qPCR for Leg. pneumophila followed the culture trend. In hot and cold water, culture and qPCR gave similar results, particularly for Leg. pneumophila. There were some marked exceptions with temperatures ≥50°C, or in the presence of supplementary biocides. Action and alert levels for qPCR were derived that gave results comparable to the application of the European Guidelines based on culture. Algorithms are proposed for the use of qPCR for routine monitoring. Action and alert levels for qPCR can be adjusted to ensure public health is protected with the benefit that remedial actions can be validated earlier with only a small increase in the frequency of action being required. This study confirms it is possible to derive guidelines on the use of qPCR for monitoring the control of legionellae with consequent improvement to response and public health protection. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.
Brown-headed cowbirds (Molothrus ater) harbor Sarcocystis neurona and act as intermediate hosts.
Mansfield, L S; Mehler, S; Nelson, K; Elsheikha, H M; Murphy, A J; Knust, B; Tanhauser, S M; Gearhart, P M; Rossano, M G; Bowman, D D; Schott, H C; Patterson, J S
2008-05-06
We tested the hypothesis that brown-headed cowbirds (Molothrus ater) harbor Sarcocystis neurona, the agent of equine protozoal myeloencephalitis (EPM), and act as intermediate hosts for this parasite. In summer 1999, wild caught brown-headed cowbirds were collected and necropsied to determine infection rate with Sarcocystis spp. by macroscopic inspection. Seven of 381 (1.8%) birds had grossly visible sarcocysts in leg muscles with none in breast muscles. Histopathology revealed two classes of sarcocysts in leg muscles, thin-walled and thick-walled suggesting two species. Electron microscopy showed that thick-walled cysts had characteristics of S. falcatula and thin-walled cysts had characteristics of S. neurona. Thereafter, several experiments were conducted to confirm that cowbirds had viable S. neurona that could be transmitted to an intermediate host and cause disease. Specific-pathogen-free opossums fed cowbird leg muscle that was enriched for muscle either with or without visible sarcocysts all shed high numbers of sporocysts by 4 weeks after infection, while the control opossum fed cowbird breast muscle was negative. These sporocysts were apparently of two size classes, 11.4+/-0.7 microm by 7.6+/-0.4 microm (n=25) and 12.6+/-0.6 microm by 8.0+/-0 microm (n=25). When these sporocysts were excysted and introduced into equine dermal cell tissue culture, schizogony occurred, most merozoites survived and replicated long term and merozoites sampled from the cultures with long-term growth were indistinguishable from known S. neurona isolates. A cowbird Sarcocystis isolate, Michigan Cowbird 1 (MICB1), derived from thin-walled sarcocysts from cowbirds that was passaged in SPF opossums and tissue culture went on to produce neurological disease in IFNgamma knockout mice indistinguishable from that of the positive control inoculated with S. neurona. This, together with the knowledge that S. falcatula does not cause lesions in IFNgamma knockout mice, showed that cowbird leg muscles had a Sarcocystis that fulfills the first aim of Koch's postulates to produce disease similar to S. neurona. Two molecular assays provided further support that both S. neurona and S. falcatula were present in cowbird leg muscles. In a blinded study, PCR-RFLP of RAPD-derived DNA designed to discriminate between S. neurona and S. falcatula showed that fresh sporocysts from the opossum feeding trial had both Sarcocystis species. Visible, thick-walled sarcocysts from cowbird leg muscle were positive for S. falcatula but not S. neurona; thin-walled sarcocysts typed as S. neurona. In 1999, DNA was extracted from leg muscles of 100 wild caught cowbirds and subjected to a PCR targeting an S. neurona specific sequence of the small subunit ribosomal RNA (SSU rRNA) gene. In control spiking experiments, this assay detected DNA from 10 S. neurona merozoites in 0.5g of muscle. In the 1999 experiment, 23 of 79 (29.1%) individual cowbird leg muscle samples were positive by this S. neurona-specific PCR. Finally, in June of 2000, 265 cowbird leg muscle samples were tested by histopathology for the presence of thick- and thin-walled sarcocysts. Seven percent (18/265) had only thick-walled sarcocysts, 0.8% (2/265) had only thin-walled sarcocysts and 1.9% (5/265) had both. The other half of these leg muscles when tested by PCR-RFLP of RAPD-derived DNA and SSU rRNA PCR showed a good correlation with histopathological results and the two molecular typing methods concurred; 9.8% (26/265) of cowbirds had sarcocysts in muscle, 7.9% (21/265) had S. falcatula sarcocysts, 1.1% (3/265) had S. neurona sarcocysts, and 0.8% (2/265) had both. These results show that some cowbirds have S. neurona as well as S. falcatula in their leg muscles and can act as intermediate hosts for both parasites.
Weather and childbirth: a further search for relationships.
Driscoll, D M
1995-03-01
Previous attempts to find relationships between weather and parturition (childbirth) and its onset (the beginning of labor pains) have revealed, firstly, limited but statistically significant relationships between weather conditions much colder than the day before, with high winds and low pressure, and increased onsets; and secondly, increased numbers of childbirths during periods of atmospheric pressure rise (highly statistically significant). To test these findings, this study examined weather data coincident childbirth data from a hospital at Bryan-College Station, Texas (for a period of 30 cool months from 1987 to 1992). Tests for (1) days of cold fronts, (2) a day before and a day after the cold front, (3) days with large temperature increases, and (4) decreases from the day before revealed no relationship with mean daily rate of onset. Cold days with high winds and low pressure had significantly fewer onsets, a result that is the opposite of previous findings. The postulated relationship between periods of pressure rise and increased birth frequency was negative, i.e., significantly fewer births occurred at those times--again, the opposite of the apparent occurrence in an earlier study. The coincidence of diurnal variations in both atmospheric pressure and frequency of childbirths, was shown to account for fairly strong negative associations between the two variables.(ABSTRACT TRUNCATED AT 250 WORDS)
Bonetta, Sa; Bonetta, Si; Ferretti, E; Balocco, F; Carraro, E
2010-05-01
This study was designed to define the extent of water contamination by Legionella pneumophila of certain Italian hotels and to compare quantitative real-time PCR with the conventional culture method. Nineteen Italian hotels of different sizes were investigated. In each hotel three hot water samples (boiler, room showers, recycling) and one cold water sample (inlet) were collected. Physico-chemical parameters were also analysed. Legionella pneumophila was detected in 42% and 74% of the hotels investigated by the culture method and by real-time PCR, respectively. In 21% of samples analysed by the culture method, a concentration of >10(4) CFU l(-1) was found, and Leg. pneumophila serogroup 1 was isolated from 10.5% of the hotels. The presence of Leg. pneumophila was significantly influenced by water sample temperature, while no association with water hardness or residual-free chlorine was found. This study showed a high percentage of buildings colonized by Leg. pneumophila. Moreover, real-time PCR proved to be sensitive enough to detect lower levels of contamination than the culture method. This study indicates that the Italian hotels represent a possible source of risk for Legionnaires' disease and confirms the sensitivity of the molecular method. To our knowledge, this is the first report to demonstrate Legionella contamination in Italian hotels using real-time PCR and culture methods.
Cooper, Kari M; Till, Christy B; Kent, Adam J R; Costa, Fidel; Rubin, Allison E; Gravley, Darren; Deering, Chad; Cole, Jim; Bose, Maitrayee
2017-12-22
In a recent paper, we used Li concentration profiles and U-Th ages to constrain the thermal conditions of magma storage. Wilson and co-authors argue that the data instead reflect control of Li behavior by charge balance during partitioning and not by experimentally determined diffusion rates. Their arguments are based on (i) a coupled diffusion mechanism for Li, which has been postulated but has not been documented to occur, and (ii) poorly constrained zircon growth rates combined with the assumption of continuous zircon crystallization. Copyright © 2017, American Association for the Advancement of Science.
Microbial ecology of extreme environments: Antarctic yeasts and growth in substrate-limited habitats
NASA Technical Reports Server (NTRS)
Vishniac, H. S.
1985-01-01
The high, dry valleys of the Ross Desert of Antarctic, characterized by extremely low temperatures, aridity and a depauperate biota, are used as an analog of the postulated extreme climates of other planetary bodies of the Solar System to test the hypothesis that if life could be supported by Ross, it might be possible where similar conditions prevail. The previously considered sterility of the Ross Desert soil ecosystem has yielded up an indigenous yeast, Cryptoccus vishniacci, which is able to resist the extremes of cold, wet and dry freezing, and long arid periods, while making minimal nutritional demands on the soil.
NASA Technical Reports Server (NTRS)
Curtis, S. A.; Wu, C. S.
1979-01-01
The paper derives the growth rates and growth lengths of the electrostatic emission for spatially homogeneous and inhomogeneous energetic electrons, and numerically evaluates the growth rate and growth length spectra for several parameter sets representative of magnetospheric plasmas. In addition, the growth rates are derived for the case of electromagnetic emission modeled by the ordinary mode. The numerical results of the electromagnetic and electrostatic cases are compared with observations made by satellites in the earth's magnetosphere. It is concluded that the electrostatic gyroharmonic excitation is possible without the cold composition of plasma which is often postulated in the existing literature.
Advances in modelling of condensation phenomena
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W.S.; Zaltsgendler, E.; Hanna, B.
1997-07-01
The physical parameters in the modelling of condensation phenomena in the CANDU reactor system codes are discussed. The experimental programs used for thermal-hydraulic code validation in the Canadian nuclear industry are briefly described. The modelling of vapour generation and in particular condensation plays a key role in modelling of postulated reactor transients. The condensation models adopted in the current state-of-the-art two-fluid CANDU reactor thermal-hydraulic system codes (CATHENA and TUF) are described. As examples of the modelling challenges faced, the simulation of a cold water injection experiment by CATHENA and the simulation of a condensation induced water hammer experiment by TUFmore » are described.« less
Effect of cold-water immersion on skeletal muscle contractile properties in soccer players.
García-Manso, Juan Manuel; Rodríguez-Matoso, Darío; Rodríguez-Ruiz, David; Sarmiento, Samuel; de Saa, Yves; Calderón, Javier
2011-05-01
This study was designed to analyze changes in muscle response after cold-water immersion. The vastus lateralis of the dominant leg was analyzed in 12 professional soccer players from the Spanish 2nd Division B using tensiomyography, before and after four cold-water immersions at 4°C lasting 4 mins each. Core temperature, skin temperature, and heart rate were monitored. A significant interaction (P ≤ 0.05) was found in muscle deformation between control conditions (5.12 ± 2.27 mm) and (1) immersion 3 (3.64 ± 2.27 mm) and (2) immersion 4 (3.38 ± 1.34 mm). A steady decrease was also observed in response velocity (immersion 1, -7.3%; immersion 2, -25.9%; immersion 3, -30.0%; immersion 4, -36.6%) and contraction velocity (immersion 1, -11.5%; immersion 2, -22.1%; immersion 3, -35.0%; immersion 4, -41.9%), with statistically significant differences (P ≤ 0.05) in relation to the reference values commencing with the third immersion. No significant differences were found between control conditions in subsequent exposures to cold water for the values of response time and contraction time. Sustained time and reaction time showed an increase during repeated exposures and with longer exposure time, although the increase was not statistically significant. This study shows that repeated cold-water immersions (4 × 4 mins at 4°C) cause considerable alterations to muscle behavior. These alterations significantly affect the state of muscles and their response capacity, particularly in relation to muscle stiffness and muscle contraction velocity.
Apollo’s Warriors: United States Air Force Special Operations during the Cold War
1997-01-01
er, and that was the unique manner in which they were packed for long-term storage. "Seal and peel " was a technique developed specifically to...for the aerial refueling leg. Refueling silently, ing the president’s approval would pick the the helos watched their tankers peel away, to be exact...130E C-130E HC-130P HC-130P HH-3 HH-53 HH-53 HH-53 HH-53 HH-53 A-1E Call Sign Cherry 1 Cherry 2 Lime 01 Lime 02 Banana 1 Apple 1
Focal myositis of lower extremity responsive to botulinum A toxin.
Mitrovic, Josko; Prka, Zeljko; Zic, Rado; Marusic, Srecko; Morovic-Vergles, Jadranka
2014-01-01
Focal myositis is a rare, mostly benign disease (pseudotumor) of skeletal muscle, histopathologically characterized by interstitial myositis and tumorous enlargement of a single muscle. The etiology of focal myositis remains unknown; however, localized myopathy has been postulated to be caused by denervation lesions. This case report describes a patient that presented with clinical, laboratory, electromyoneurography, and magnetic resonance imaging features of focal myositis complicated with intervertebral disk protrusion in the lumbosacral spine affected with radicular distress. In most cases, focal myositic lesions show spontaneous regression, relapses are rare, and long-term prognosis is good. There is a wide spectrum of therapeutic options, from no therapy at all through nonsteroidal antirheumatics and glucocorticoids to radiotherapy, surgical excision, and immunosuppressants. In the patient presented, treatment with glucocorticoids, methotrexate, and surgical excision failed to produce satisfactory results. Clinical improvement, pain relief, and reduction in lower leg volume were only achieved by local infiltration of botulinum A toxin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, Subhasish; Soppet, William; Majumdar, Saurin
This report provides an update on an assessment of environmentally assisted fatigue for light water reactor components under extended service conditions. This report is a deliverable under the work package for environmentally assisted fatigue as part of DOE’s Light Water Reactor Sustainability Program. In a previous report (September 2015), we presented tensile and fatigue test data and related hardening material properties for 508 low-alloys steel base metal and other reactor metals. In this report, we present thermal-mechanical stress analysis of the reactor pressure vessel and its hot-leg and cold-leg nozzles based on estimated material properties. We also present results frommore » thermal and thermal-mechanical stress analysis under reactor heat-up, cool-down, and grid load-following conditions. Analysis results are given with and without the presence of preexisting cracks in the reactor nozzles (axial or circumferential crack). In addition, results from validation stress analysis based on tensile and fatigue experiments are reported.« less
Purification and Characterization of a Cold-Adapted Lipase from Oceanobacillus Strain PT-11
Jiewei, Tian; Zuchao, Lei; Peng, Qiu; Lei, Wang; Yongqiang, Tian
2014-01-01
We isolated a moderately halophilic lipase-producing bacterium from the saline soil. Based on the morphological, physiological, chemotaxonomic and phylogenetic analysis, the isolate PT-11 was postulated to be a novel species identified as Oceanobacillus rekensis PT-11. The lipase was purified 2.50-fold by Q-Sepharose FF and SP-Sepharose FF chromatography and its molecular mass was estimated to be 23.5 kDa by SDS-PAGE. It was highly active over the broad temperature ranging from 10 to 35°C and showed up to 80% of the maximum activity at 10°C indicating the lipase to be a typical cold-adapted enzyme. The enzyme activity was slightly enhanced by Na+, Li+ and K+. Incubation with detergents, such as Tween-20 and Tween-80, slightly inhibited the enzyme activity; while Triton X-100decreased the enzyme activity. The enzyme was fairly stable in the presence of long-chain alcohols but was highly denatured in hydrophilic solvents such as acetone or short-chain alcohols (C1–C3). PMID:24984141
Effect of demedullation on freezing injury in hind limbs of rats
NASA Astrophysics Data System (ADS)
Dhingra, Shashi; Bhatia, B.; Chhina, G. S.; Singh, Baldev
1987-09-01
Freezing incidence and tissue loss on exposure of hind limbs of female Wistar rats to freezing mixture was reduced by demedullation 6 days prior to cold exposure (p<0.01 and p<0.001 respectively); demedullation 1 h after freezing injury had no effect on tissue loss. Noradrenaline (1 mg/kg i.p.) 5 min before exposure increased the freezing incidence in intact (p<0.05) as well as in demedullated rats (p<0.01), with no effect on tissue loss. Adrenaline (500 mg/kg i.p.) had no effect on either. A sustained fall in plasma adrenaline after demedullation leading to reduced reactivity of the blood vessels to some vasoactive agents is postulated.
Wilder-Smith, Oliver Hamilton; Schreyer, Tobias; Scheffer, Gert Jan; Arendt-Nielsen, Lars
2010-06-01
Chronic pain is common and undesirable after surgery. Progression from acute to chronic pain involves altered pain processing. The authors studied relationships between presence of chronic pain versus preoperative descending pain control (diffuse noxious inhibitory controls; DNICs) and postoperative persistence and spread of skin and deep tissue hyperalgesia (change in electric/pressure pain tolerance thresholds; ePTT/pPTT) up to 6 months postoperatively. In 20 patients undergoing elective major abdominal surgery under standardized anesthesia, we determined ePTT/pPTT (close to [abdomen] and distant from [leg] incision), eDNIC/pDNIC (change in ePTT/pPTT with cold pressor pain task; only preoperatively), and a 100 mm long pain visual analogue scale (VAS) (0 mm = no pain, 100 mm = worst pain imaginable), both at rest and on movement preoperatively, and 1 day and 1, 3, and 6 months postoperatively. Patients reporting chronic pain 6 months postoperatively had more abdominal and leg skin hyperalgesia over the postoperative period. More inhibitory preoperative eDNIC was associated with less late postoperative pain, without affecting skin hyperalgesia. More inhibitory pDNIC was linked to less postoperative leg deep tissue hyperalgesia, without affecting pain VAS. This pilot study for the first time links chronic pain after surgery, poorer preoperative inhibitory pain modulation (DNIC), and greater postoperative degree, persistence, and spread of hyperalgesia. If confirmed, these results support the potential clinical utility of perioperative pain processing testing.
Rius-Vilarrasa, E; Bünger, L; Maltin, C; Matthews, K R; Roehe, R
2009-05-01
The Meat and Livestock Commission's (MLC) EUROP classification based scheme and Video Image Analysis (VIA) system were compared in their ability to predict weights of primal carcass joints. A total of 443 commercial lamb carcasses under 12 months of age and mixed gender were selected by their cold carcass weight (CCW), conformation and fat scores. Lamb carcasses were classified for conformation and fatness, scanned by the VIA system and dissected into primal joints of leg, chump, loin, breast and shoulder. After adjustment for CCW, the estimation of primal joints using MLC EUROP scores showed high coefficients of determination (R(2)) in the range of 0.82-0.99. The use of VIA always resulted in equal or higher R(2). The precision measured as root mean square error (RMSE) was 27% (leg), 13% (chump), 1% (loin), 11% (breast), 5% (shoulders) and 13% (total primals) higher using VIA than MLC carcass information. Adjustment for slaughter day and gender effects indicated that estimations of primal joints using MLC EUROP scores were more sensitive to these factors than using VIA. This was consistent with an increase in stability of the prediction model of 28%, 11%, 2%, 12%, 6% and 14% for leg, chump, loin, breast and shoulder and total primals, respectively, using VIA compared to MLC EUROP scores. Consequently, VIA was capable of improving the prediction of primal meat yields compared to the current MLC EUROP carcass classification scheme used in the UK abattoirs.
NASA Astrophysics Data System (ADS)
Kaila, M. M.
2002-11-01
Dynamical theory of responsivity and response time for an high temperature superconductor (HTSC) photo-thermoelectrical bolometer is analysed in this paper. There is a thermoelectric feedback (TEF) due to the heat transfer from the sensitive area (HTSC-BiSb thermojunction) towards the cold junction of the thermocouple. This is in addition to the normal electrothermal feedback (ETF) between the detector and the substrate, in a photoelectrical bolometer. The two legs of the thermocouple are connected in a parallel geometry configuration. It is seen that TEF can be used in combination with the ETF to enhance responsivity and response time of the detector.
Brynsvold, Glen V.; Lopez, John T.; Olich, Eugene E.; West, Calvin W.
1989-01-01
An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates.
Brynsvold, G.V.; Lopez, J.T.; Olich, E.E.; West, C.W.
1989-11-21
An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates. 14 figs.
Fleet Assignment Using Collective Intelligence
NASA Technical Reports Server (NTRS)
Antoine, Nicolas E.; Bieniawski, Stefan R.; Kroo, Ilan M.; Wolpert, David H.
2004-01-01
Airline fleet assignment involves the allocation of aircraft to a set of flights legs in order to meet passenger demand, while satisfying a variety of constraints. Over the course of the day, the routing of each aircraft is determined in order to minimize the number of required flights for a given fleet. The associated flow continuity and aircraft count constraints have led researchers to focus on obtaining quasi-optimal solutions, especially at larger scales. In this paper, the authors propose the application of an agent-based integer optimization algorithm to a "cold start" fleet assignment problem. Results show that the optimizer can successfully solve such highly- constrained problems (129 variables, 184 constraints).
Hard X-Ray-emitting Black Hole Fed by Accretion of Low Angular Momentum Matter
NASA Astrophysics Data System (ADS)
Igumenshchev, Igor V.; Illarionov, Andrei F.; Abramowicz, Marek A.
1999-05-01
Observed spectra of active galactic nuclei and luminous X-ray binaries in our Galaxy suggest that both hot (~109 K) and cold (~106 K) plasma components exist close to the central accreting black hole. The hard X-ray component of the spectra is usually explained by Compton upscattering of optical/UV photons from optically thick cold plasma by hot electrons. Observations also indicate that some of these objects are quite efficient in converting gravitational energy of accretion matter into radiation. Existing theoretical models have difficulties in explaining the two plasma components and high intensity of hard X-rays. Most of the models assume that the hot component emerges from the cold one because of some kind of instability, but no one offers a satisfactory physical explanation for this. Here we propose a solution to these difficulties that reverses what was imagined previously: in our model, the hot component forms first and afterward it cools down to form the cold component. In our model, the accretion flow initially has a small angular momentum, and thus it has a quasi-spherical geometry at large radii. Close to the black hole, the accreting matter is heated up in shocks that form because of the action of the centrifugal force. The hot postshock matter is very efficiently cooled down by Comptonization of low-energy photons and condensates into a thin and cool accretion disk. The thin disk emits the low-energy photons which cool the hot component. All the properties of our model, in particular the existence of hot and cold components, follow from an exact numerical solution of standard hydrodynamical equations--we postulate no unknown processes operating in the flow. In contrast to the recently discussed advection-dominated accretion flow, the particular type of accretion flow considered in this Letter is both very hot and quite radiatively efficient.
NASA Astrophysics Data System (ADS)
Guo, Qinghai; Wang, Yanxin; Liu, Wei
2007-10-01
The Yangbajing geothermal field with the highest reservoir temperature in China is located about 90 km northwest to Lhasa City, capital of Tibet, where high temperature geothermal fluids occur both in shallow and deep reservoirs. The geophysical survey by the INDEPTH (International Deep Profiling of Tibet and the Himalayas) project group proved the existence of magmatic heat source at Yangbajing. In the study area, the hydrochemistry of cold surface waters and groundwaters and that of thermal groundwaters from both reservoirs are distinctively different. However, analysis of the relationship between enthalpy values and Cl concentrations of cold groundwaters and geothermal fluids indicates that the geothermal fluids from the shallow reservoir were formed as a result of mixing of cold groundwaters with geothermal fluids from the deep reservoir. In other words, the geothermal fluids from the deep reservoir flowed upwards into the shallow reservoir where it was diluted by the shallow cold groundwaters to form the shallow geothermal fluids with much lower temperature. A binary mixing model with two endmembers (the cold groundwaters and the deep geothermal fluids) was proposed and the mixing ratios for the geothermal fluid from each shallow well were estimated. Using the mixing ratios, the concentrations of some constituents in shallow geothermal fluids, such as As, B, SiO 2, SO 42- and F, were calculated and their differences with the actual concentrations were estimated. The results show that the differences between estimated and actual concentrations of As and B are small (the average absolute values being only 1.9% and 7.9%, respectively), whereas those of SiO 2, SO 42- and F are much bigger, indicating that other hydrogeochemical processes are responsible for the concentrations of these constituents. It is postulated that SiO 2 precipitation due to water temperature decrease, H 2S oxidation and ion exchange between OH - in geothermal waters and exchangeable F - in fluoride bearing silicate minerals during the geothermal fluid upflow might be the causes for the observed concentration differences.
Graham, L A; Walker, V K; Davies, P L
2000-11-01
The yellow mealworm beetle, Tenebrio molitor, contains a family of small Cys-rich and Thr-rich thermal hysteresis proteins that depress the hemolymph freezing point below the melting point by as much as 5. 5 degrees C (DeltaT = thermal hysteresis). Thermal hysteresis protein expression was evaluated throughout development and after exposure to altered environmental conditions. Under favorable growth conditions, small larvae (11-13 mg) had only low levels of thermal hysteresis proteins or thermal hysteresis protein message, but these levels increased 10-fold and 18-fold, respectively, by the final larval instar (> 190 mg), resulting in thermal hysteresis > 3 degrees C. Exposure of small larvae (11-13 mg) to 4 weeks of cold (4 degrees C) caused an approximately 20-fold increase in thermal hysteresis protein concentration, well in excess of the less than threefold developmental increase seen after 4 weeks at 22 degrees C. Exposure of large larvae (100-120 mg) to cold caused 12-fold and sixfold increases in thermal hysteresis protein message and protein levels, respectively, approximately double the maximum levels they would have attained in the final larval instar at 22 degrees C. Thus, thermal hysteresis increased to similar levels (> 4 degrees C) in the cold, irrespective of the size of the larvae (the overwintering stage). At pupation, thermal hysteresis protein message levels decreased > 20-fold and remained low thereafter, but thermal hysteresis activity decreased much more slowly. Exposure to cold did not reverse this decline. Desiccation or starvation of larvae had comparable effects to cold exposure, but surprisingly, short daylength photoperiod or total darkness had no effect on either thermal hysteresis or message levels. As all environmental conditions that caused increased thermal hysteresis also inhibited growth, we postulate that developmental arrest is a primary factor in the regulation of T. molitor thermal hysteresis proteins.
Slanger, W D; Marchello, M J; Busboom, J R; Meyer, H H; Mitchell, L A; Hendrix, W F; Mills, R R; Warnock, W D
1994-06-01
Data of sixty finished, crossbred lambs were used to develop prediction equations of total weight of retail-ready cuts (SUM). These cuts were the leg, sirloin, loin, rack, shoulder, neck, riblets, shank, and lean trim (85/15). Measurements were taken on live lambs and on both hot and cold carcasses. A four-terminal bioelectrical impedance analyzer (BIA) was used to measure resistance (Rs, ohms) and reactance (Xc, ohms). Distances between detector terminals (L, centimeters) were recorded. Carcass temperatures (T, degrees C) at time of BIA readings were also recorded. The equation predicting SUM from cold carcass measurements (n = 53, R2 = .97) was .093 + .621 x weight-.0219 x Rs + .0248 x Xc + .182 x L-.338 x T. Resistance accounted for variability in SUM over and above weight and L (P = .0016). The above equation was used to rank cold carcasses in descending order of predicted SUM. An analogous ranking was obtained from a prediction equation that used weight only (R2 = .88). These rankings were divided into five categories: top 25%, middle 50%, bottom 25%, top 50%, and bottom 50%. Within-category differences in average fat cover, yield grade, and SUM as a percentage of cold carcass weight of carcasses not placed in the same category by both prediction equations were quantified with independent t-tests. These differences were statistically significant for all categories except middle 50%. This shows that BIA located those lambs that could more efficiently contribute to SUM because a higher portion of their weight was lean.
2013-01-01
Background The role of abscisic acid (ABA) as a possible activator of cold acclimation process was postulated since endogenous levels of ABA increase temporarily or constitutively during cold-hardening. Exogenous application of ABA has been known to induce freezing tolerance at ambient temperatures in in vitro systems derived from cold hardy plants. Yet, some cell cultures acquired much greater freezing tolerance by ABA than by cold whilst maintaining active growth. This raises questions about the relationships among ABA, cold acclimation and growth cessation. To address this question, we attempted to 1) determine whether exogenous ABA can confer freezing tolerance in chilling-sensitive rice suspension cells and seedlings, which obviously lack the mechanisms to acquire freezing tolerance in response to cold; 2) characterize this phenomenon by optimizing the conditions and compare with the case of cold hardy bromegrass cells. Results Non-embryogenic suspension cells of rice suffered serious chilling injury when exposed to 4°C. When incubated with ABA at the optimal conditions (0.5-1 g cell inoculum, 75 μM ABA, 25-30°C, 7–10 days), they survived slow freezing (2°C/h) to −9.0 ~ −9.3°C (LT50: 50% killing temperature) while control cells were mostly injured at −3°C (LT50: -0.5 ~ −1.5°C). Ice-inoculation of the cell suspension at −3°C and survival determination by regrowth confirmed that ABA-treated rice cells survived extracellular freezing at −9°C. ABA-induced freezing tolerance did not require any exposure to cold and was best achieved at 25-30°C where the rice cells maintained high growth even in the presence of ABA. ABA treatment also increased tolerance to heat (43°C) as determined by regrowth. ABA-treated cells tended to have more augmented cytoplasm and/or reduced vacuole sizes compared to control cultures with a concomitant increase in osmolarity and a decrease in water content. ABA-treated (2–7 days) in vitro grown seedlings and their leaves survived slow freezing to −3°C with only marginal injury (LT50: -4°C) whereas untreated seedlings were killed at −3°C (LT50: -2°C). Conclusions The results indicate that exogenous ABA can induce some levels of freezing tolerance in chilling-sensitive rice cells and seedlings, probably by eliciting mechanisms different from low temperature-induced cold acclimation. PMID:24004611
The Pleistocene biogeography of eastern North America: A nonmigration scenario for deciduous forest
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loehle, C.; Iltis, H.
The current reconstruction of the vegetation of eastern North America at the last glacial maximum postulates a very wide zone of tundra and boreal forest south of the ice. This reconstruction requires that the deciduous forest retreated far to the south. The authors believe that this reconstruction is seriously in error. Geologic evidence for glacial activity or tundra is absent from the southern Appalachians. Positive evidence for boreal forest is based on pollen identifications for Picea, Betula, and Pinus, when in reality southern members of these genera have pollen that cannot be distinguished from that of northern members. Further, pollenmore » of typical southern species such as oaks and hickories occurs throughout profiles that past authors had labeled boreal. Pollen evidence for a far southern deciduous forest refuge is lacking. Data on endemics are particularly challenging for the scenario in which deciduous forest migrated to the south and back. The southern Appalachian region is rife with endemics that are often extreme-habitat specialists unable to migrate. The previously glaciated zone is almost completely lacking in endemics. Outlier populations, range boundaries, and absence of certain hybrids all argue against a large boreal zone. The new reconstruction postulates a cold zone no more than 75--100 miles wide south of the ice in the East.« less
Racinais, Sébastien; Blonc, Stephen; Oksa, Juha; Hue, Olivier
2009-01-01
Seven male subjects volunteered to participate in an investigation of whether the diurnal increase in core temperature influences the effects of pre-cooling or passive warm-up on muscular power. Morning (07:00-09:00h) and afternoon (17:00-19:00h) evaluation of maximal power output during a cycling sprint was performed on different days in a control condition (room at 21.8 degrees C, 69% rh), after 30min of pre-cooling in a cold bath (16 degrees C), or after 30min of passive warm-up in a hot bath (38 degrees C). Despite an equivalent increase from morning to afternoon in core temperature in all conditions (+0.4 degrees C, P<0.05), power output displayed a diurnal increase in control condition only. A local cooling or heating of the leg in a neutral environment blunted the diurnal variation in muscular power. Because pre-cooling decreases muscle power, force and velocity irrespective of time-of-day, athletes should strictly avoid any cooling before a sprint exercise. In summary, diurnal variation in muscle power output seems to be more influenced by muscle rather than core temperature.
VICTORIA-92 pretest analyses of PHEBUS-FPT0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bixler, N.E.; Erickson, C.M.
FPT0 is the first of six tests that are scheduled to be conducted in an experimental reactor in Cadarache, France. The test apparatus consists of an in-pile fuel bundle, an upper plenum, a hot leg, a steam generator, a cold leg, and a small containment. Thus, the test is integral in the sense that it attempts to simulate all of the processes that would be operative in a severe nuclear accident. In FPT0, the fuel will be trace irradiated; in subsequent tests high burn-up fuel will be used. This report discusses separate pretest analyses of the FPT0 fuel bundle andmore » primary circuit have been conducted using the USNRC`s source term code, VICTORIA-92. Predictions for release of fission product, control rod, and structural elements from the test section are compared with those given by CORSOR-M. In general, the releases predicted by VICTORIA-92 occur earlier than those predicted by CORSOR-M. The other notable difference is that U release is predicted to be on a par with that of the control rod elements; CORSOR-M predicts U release to be about 2 orders of magnitude greater.« less
Precooling leg muscle improves intermittent sprint exercise performance in hot, humid conditions.
Castle, Paul C; Macdonald, Adam L; Philp, Andrew; Webborn, Anthony; Watt, Peter W; Maxwell, Neil S
2006-04-01
We used three techniques of precooling to test the hypothesis that heat strain would be alleviated, muscle temperature (Tmu) would be reduced, and as a result there would be delayed decrements in peak power output (PPO) during exercise in hot, humid conditions. Twelve male team-sport players completed four cycling intermittent sprint protocols (CISP). Each CISP consisted of twenty 2-min periods, each including 10 s of passive rest, 5 s of maximal sprint against a resistance of 7.5% body mass, and 105 s of active recovery. The CISP, preceded by 20 min of no cooling (Control), precooling via an ice vest (Vest), cold water immersion (Water), and ice packs covering the upper legs (Packs), was performed in hot, humid conditions (mean +/- SE; 33.7 +/- 0.3 degrees C, 51.6 +/- 2.2% relative humidity) in a randomized order. The rate of heat strain increase during the CISP was faster in Control than Water and Packs (P < 0.01), but it was similar to Vest. Packs and Water blunted the rise of Tmu until minute 16 and for the duration of the CISP (40 min), respectively (P < 0.01). Reductions in PPO occurred from minute 32 onward in Control, and an increase in PPO by approximately 4% due to Packs was observed (main effect; P < 0.05). The method of precooling determined the extent to which heat strain was reduced during intermittent sprint cycling, with leg precooling offering the greater ergogenic effect on PPO than either upper body or whole body cooling.
NASA Technical Reports Server (NTRS)
Hackney, K. J.; Everett, M.; Ploutz-Snyder, L. L.
2011-01-01
High-load resistance exercise (HRE) and low-load blood flow restricted (BFR) exercise have demonstrated efficacy for attenuating unloading related muscle atrophy and dysfunction. In recreational exercisers, protein consumption immediately before and/or after exercise has been shown to increase the skeletal muscle anabolic response to resistance training. PURPOSE: To compare the skeletal muscle adaptations when chocolate milk intake was coupled with HRE or low-load BFR exercise [3 d/wk] during simulated lower limb weightlessness. METHODS: Eleven subjects were counterbalanced [based on age and gender] to HRE (31 +/- 14 yr, 170 +/- 13 cm, 71 +/- 18 kg, 2M/3W) or low-load BFR exercise (31 +/- 12 yr, 169 +/- 13 cm, 66 +/- 14 kg, 2M/4W) during 30 days of unilateral lower limb suspension (ULLS). Both HRE and BFR completed 3 sets of single leg press and calf raise exercise during ULLS. BFR exercise intensity was 20% of repetition maximum (1RM) with a cuff inflation pressure of 1.3 systolic blood pressure (143 4 mmHg). Cuff pressure was maintained during all 3 sets including rest intervals (90s). HRE intensity was 75% 1RM and was performed without cuff inflation. Immediately (<10 min) before and after exercise 8 fl oz of chocolate milk (150 kcal, 2.5g total fat, 22g total carbohydrate, 8g protein) was consumed to optimize acute exercise responses in favor of muscle anabolism. ULLS analog compliance was assessed from leg skin temperature recordings and plantar accelerometry. Muscle cross-sectional area (CSA) for knee extensor and plantar flexor muscle groups were determined from analysis of magnetic resonance images using ImageJ software. 1RM strength for leg press and calf raise was assessed on the Agaton exercise system. Muscular endurance during leg press and calf raise was evaluated from the maximal number of repetitions performed to volitional fatigue using 40% of pre-ULLS 1RM. RESULTS: Steps detected by plantar acceleometry declined by 98.9% during ULLS relative to an ambulatory control period. Average skin temperature of the unloaded calf declined from 27.4 C to 26.8 C (-2.1%), while there was a slight increase (+1.1%) in skin temperature in the loaded calf (27.6 C to 27.9 C). Collectively, these measures indicate strong subject compliance with the ULLS analog. Unloaded limb work performed during leg press (1514 +/- 334 vs. 576 +/- 103) and calf raise (2886 +/- 508 vs. 1233 +/- 153) exercises sessions was greater in HRE vs. BFR, respectively. Leg press training loads were 44 +/- 7 kg in HRE compared to 11 +/- 1 kg in BFR. Similarly, calf raise training loads were 81 +/- 11 kg in HRE and 16 +/- 1 kg in BFR. Pre to post-ULLS training adaptations in the unloaded leg are shown in the table. CONCLUSION: The preliminary results of this investigation suggest when HRE is optimized for muscle anabolism during unloading muscle size and strength are preserved (or enhanced) at the expense of muscle endurance. In contrast, when BFR exercise is optimized for muscle anabolism during unloading muscle endurance is preserved (or enhanced) at the expense of muscle size and strength
Solar Magnetized Tornadoes: Rotational Motion in a Tornado-like Prominence
NASA Astrophysics Data System (ADS)
Su, Yang; Gömöry, Peter; Veronig, Astrid; Temmer, Manuela; Wang, Tongjiang; Vanninathan, Kamalam; Gan, Weiqun; Li, YouPing
2014-04-01
Su et al. proposed a new explanation for filament formation and eruption, where filament barbs are rotating magnetic structures driven by underlying vortices on the surface. Such structures have been noticed as tornado-like prominences when they appear above the limb. They may play a key role as the source of plasma and twist in filaments. However, no observations have successfully distinguished rotational motion of the magnetic structures in tornado-like prominences from other motions such as oscillation and counter-streaming plasma flows. Here we report evidence of rotational motions in a tornado-like prominence. The spectroscopic observations in two coronal lines were obtained from a specifically designed Hinode/EIS observing program. The data revealed the existence of both cold and million-degree-hot plasma in the prominence leg, supporting the so-called prominence-corona transition region. The opposite velocities at the two sides of the prominence and their persistent time evolution, together with the periodic motions evident in SDO/AIA dark structures, indicate a rotational motion of both cold and hot plasma with a speed of ~5 km s-1.
Ross, Edward V; Chuang, Gary S; Ortiz, Arisa E; Davenport, Scott A
2018-04-01
High concentrations of sub-micron nanoparticles have been shown to be released during laser hair removal (LHR) procedures. These emissions pose a potential biohazard to healthcare workers that have prolonged exposure to LHR plume. We sought to demonstrate that cold sapphire skin cooling done in contact mode might suppress plume dispersion during LHR. A total of 11 patients were recruited for laser hair removal. They were treated on the legs and axilla with a 755 or 1064 nm millisecond-domain laser equipped with either (i) cryogen spray (CSC); (ii) refrigerated air (RA); or (iii) contact cooling with sapphire (CC). Concentration of ultrafine nanoparticles <1 μm were measured just before and during LHR with the three respective cooling methods. For contact cooling (CC), counts remained at baseline levels, below 3,500 parts per cubic centimeter (ppc) for all treatments. In contrast, the CSC system produced large levels of plume, peaking at times to over 400,000 ppc. The CA cooled system produced intermediate levels of plume, about 35,000 ppc (or about 10× baseline). Cold Sapphire Skin cooling with gel suppresses plume during laser hair removal, potentially eliminating the need for smoke evacuators, custom ventilation systems, and respirators during LHR. Lasers Surg. Med. 50:280-283, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Weather and childbirth: A further search for relationships
NASA Astrophysics Data System (ADS)
Driscoll, Dennis M.
1995-09-01
Previous attempts to find relationships between weather and parturition (childbirth) and its onset (the beginning of labor pains) have revealed, firstly, limited but statistically significant relationships between weather conditions much colder than the day before, with high winds and low pressure, and increased onsets; and secondly, increased numbers of childbirths during periods of atmospheric pressure rise (highly statistically significant). To test these findings, this study examined weather data coincident childbirth data from a hospital at Bryan-College Station, Texas (for a period of 30 cool months from 1987 to 1992). Tests for (1) days of cold fronts, (2) a day before and a day after the cold front, (3) days with large temperature increases, and (4) decreases from the day before revealed no relationship with mean daily rate of onset. Cold days with high winds and low pressure had significantly fewer onsets, a result that is the opposite of previous findings. The postulated relationship between periods of pressure rise and increased birth frequency was negative, i.e., significantly fewer births occurred at those times — again, the opposite of the apparent occurrence in an earlier study. The coincidence of diurnal variations in both atmospheric pressure and frequency of childbirths, was shown to account for fairly strong negative associations between the two variables. This same reasoning might explain the positive association found in an earlier study. A comparison has been made between childbirth and onset as the response variable, and the advantage is emphasized of using data from women whose labor is not induced.
Ha, M; Tokura, H; Tanaka, Y; Holmér, I
1996-01-01
Thermophysiological responses and clothing microclimate under the influences of different underwear materials were compared during walking and recovery in the cold. Two kinds of underwear were used: two layers of cotton underwear with two-piece long-sleeved shirt and long-legged trousers (C), two layers of polypropylene underwear with two-piece long-sleeved shirt and long-legged trousers (P). In addition, the subject put on a two-piece ski suit of 100% polyester including 100% polyester padding. Seven adult females served as subjects in this study. The test was done in a climatic chamber at an ambient air temperature of 2 degrees C, a relative humidity of 65% and an air velocity of 0.14 m.s-1. The subject walked on a motor-driven treadmill with a 6 km/h speed for 30 min followed by 60 min recovery. Rectal temperature, skin temperatures, clothing microclimate (temperature, humidity), metabolic heat production and heart rate were measured. Furthermore, subjective ratings on thermal sensation, sweating/shivering sensation, clothing wettedness sensation and skin wettedness sensation for whole body were asked. The major findings are summarized as follows: 1) Mean skin temperature was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 2) The absolute humidity of innermost layer and outermost layer were not significantly different during walking, but it was significantly higher in P than in C during the recovery. 3) Clothing microclimate temperature of innermost was not significantly different during the first half of walking, but it was significantly higher in C than in P during the second half of walking and significantly lower in C than in P during the recovery. Clothing microclimate temperature of outermost was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 4) Metabolic heat production for the last 10 min during recovery tended to be higher in P. 5) The degree of skin wettedness sensation and clothing wettedness sensation for whole body was significantly higher in P during walking and recovery. Thus, it was concluded that two kinds of underwear with different properties to moisture could influence, not only clothing microclimate, but also physiological parameters like skin temperatures and metabolic heat production in the cold differently.
Break modeling for RELAP5 analyses of ISP-27 Bethsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petelin, S.; Gortnar, O.; Mavko, B.
This paper presents pre- and posttest analyses of International Standard Problem (ISP) 27 on the Bethsy facility and separate RELAP5 break model tests considering the measured boundary condition at break inlet. This contribution also demonstrates modifications which have assured the significant improvement of model response in posttest simulations. Calculations were performed using the RELAP5/MOD2/36.05 and RELAP5/MOD3.5M5 codes on the MicroVAX, SUN, and CONVEX computers. Bethsy is an integral test facility that simulates a typical 900-MW (electric) Framatome pressurized water reactor. The ISP-27 scenario involves a 2-in. cold-leg break without HPSI and with delayed operator procedures for secondary system depressurization.
Pretest mediction of Semiscale Test S-07-10 B. [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobbe, C A
A best estimate prediction of Semiscale Test S-07-10B was performed at INEL by EG and G Idaho as part of the RELAP4/MOD6 code assessment effort and as the Nuclear Regulatory Commission pretest calculation for the Small Break Experiment. The RELAP4/MOD6 Update 4 and the RELAP4/MOD7 computer codes were used to analyze Semiscale Test S-07-10B, a 10% communicative cold leg break experiment. The Semiscale Mod-3 system utilized an electrially heated simulated core operating at a power level of 1.94 MW. The initial system pressure and temperature in the upper plenum was 2276 psia and 604/sup 0/F, respectively.
Infrared bolometers with silicon nitride micromesh absorbers
NASA Technical Reports Server (NTRS)
Bock, J. J.; Turner, A. D.; DelCastillo, H. M.; Beeman, J. W.; Lange, A. E.; Mauskopf, P. D.
1996-01-01
Sensitive far infrared and millimeter wave bolometers fabricated from a freestanding membrane of low stress silicon nitride are reported. The absorber, consisting of a metallized silicon nitride micromesh thermally isolated by radial legs of silicon nitride, is placed in an integrating cavity to efficiently couple to single mode or multiple mode infrared radiation. This structure provides low heat capacity, low thermal conduction and minimal cross section to energetic particles. A neutron transmutation doped Ge thermister is bump bonded to the center of the device and read out with evaporated Cr-Au leads. The limiting performance of the micromesh absorber is discussed and the recent results obtained from a 300 mK cold stage are summarized.
Macrospicule Jets in On-Disk Coronal Holes
NASA Technical Reports Server (NTRS)
Adams, M. L.; Sterling, A. C.; Moore, R. L.
2014-01-01
We examine the magnetic structure and dynamics of multiple jets found in coronal holes close to or on disk center. All data are from the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI) of the Solar Dynamics Observatory (SDO). We report on observations of six jets in an equatorial coronal hole spanning 2011 February 27 and 28. We show the evolution of these jets in AIA 193 A, examine the magnetic field configuration, and postulate the probable trigger mechanism of these events. We recently reported on another jet in the same coronal hole on 2011 February 27, approximately 13:04 Universal Time (Adams et al 2014, Astrophysical Journal, 783: 11); this jet is a previously-unrecognized variety of blowout jet. In this variety, the reconnection bright point is not made by interchange reconnection of initially-closed erupting field in the base of the jet with ambient open field. Instead, there is a miniature filament-eruption flare arcade made by internal reconnection of the legs of the erupting field.
Fabrication of Lanthanum Telluride 14-1-11 Zintl High-Temperature Thermoelectric Couple
NASA Technical Reports Server (NTRS)
Ravi, Vilupanur A.; Li, Billy Chun-Yip; Fleurial, Pierre; Star, Kurt
2010-01-01
The development of more efficient thermoelectric couple technology capable of operating with high-grade heat sources up to 1,275 K is key to improving the performance of radioisotope thermoelectric generators. Lanthanum telluride La3-xTe4 and 14-1-11 Zintls (Yb14MnSb11) have been identified as very promising materials. The fabrication of advanced high-temperature thermoelectric couples requires the joining of several dissimilar materials, typically including a number of diffusion bonding and brazing steps, to achieve a device capable of operating at elevated temperatures across a large temperature differential (up to 900 K). A thermoelectric couple typically comprises a heat collector/ exchanger, metallic interconnects on both hot and cold sides, n-type and ptype conductivity thermoelectric elements, and cold-side hardware to connect to the cold-side heat rejection and provide electrical connections. Differences in the physical, mechanical, and chemical properties of the materials that make up the thermoelectric couple, especially differences in the coefficients of thermal expansion (CTE), result in undesirable interfacial stresses that can lead to mechanical failure of the device. The problem is further complicated by the fact that the thermoelectric materials under consideration have large CTE values, are brittle, and cracks can propagate through them with minimal resistance. The inherent challenge of bonding brittle, high-thermal-expansion thermoelectric materials to a hot shoe material that is thick enough to carry the requisite electrical current was overcome. A critical advantage over prior art is that this device was constructed using all diffusion bonds and a minimum number of assembly steps. The fabrication process and the materials used are described in the following steps: (1) Applying a thin refractory metal foil to both sides of lanthanum telluride. To fabricate the n-type leg of the advanced thermoelectric couple, the pre-synthesized lanthanum telluride coupon was diffusion bonded to the metal foil using a thin adhesion layer. (2) Repeating a similar process for the 14-1-11 Zintl p-type leg of the advanced thermoelectric couple. (3) Bonding thick CTE-matched metal plates on the metallized lanthanum telluride and Yb14MnSb11 to form the hot and cold sides of the thermoelectric couple. The calculated conversion efficiency of such an advanced couple would be about 10.5 percent, about 35 percent better than heritage radioisotope thermoelectric technology that relies on Si-Ge alloys. In addition, unlike Si-Ge alloys, these materials can be combined with many other thermoelectric materials optimized for operation at lower temperatures to achieve conversion efficiency in excess of 15 percent (a factor of 2 increase over heritage technology).
Lloyd, John; Lydon, Patrick; Ouhichi, Ramzi; Zaffran, Michel
2015-02-11
Accidental freezing of vaccines is a growing threat and a real risk for national immunization programs when the potency of many vaccines can be compromised if these are exposed to sub-zero temperatures in the cold chain. In Tunisia, this issue is compounded by using sub-standard domestic cold chain equipment instead of equipping the program with medical refrigerators designed specifically for storing vaccines and temperature sensitive pharmaceuticals. Against this backdrop, this paper presents the findings of a demonstration project conducted in Tunisia in 2012 that tested the impact of introducing several freeze prevention solutions to mitigate the risk of accidental freezing of vaccines. The main finding is that, despite the continued use of underperforming domestic refrigerators, continuous temperature monitoring using new technologies combined with other technological interventions significantly reduced the prevalence of accidental exposure to freezing temperatures. These improvements were noticed for cold chain storage at regional, district and health center levels, and during the transport legs that were part of the demonstration conducted in the regions of Kasserine in the South-Eastern part of Tunisia. Subsequent to introducing these freeze prevention solutions, the incidence of freeze alarms was reduced and the percent of time the temperatures dropped below the 2 °C recommended threshold. The incidence of freeze alarms at health center level was reduced by 40%. Lastly, the solutions implemented reduced risk of freezing during transport from 13.8% to 1.7%. Although the solution implemented is not optimal in the longer term because domestic refrigerators are used extensively in district stores and health centers, the risk of accidental freezing is significantly reduced by introducing the practice of continuous temperature monitoring as a standard. The management of the cold chain equipment was strengthened as a result which helps protect the potency of vaccines to the areas of most difficult access. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Imamura, Tetsuya; Ishizuka, Osamu; Sudha, Gautam Silwal; Lei, Zhang; Hosoda, Tomoka; Noguchi, Wataru; Yamagishi, Takahiro; Yokoyama, Hitoshi; Kurizaki, Yoshiki; Nishizawa, Osamu
2013-06-01
We determined if THC-002, a galenical produced from Ba-Wei-Die-Huang-Wan, could increase skin temperature and inhibit detrusor overactivity induced by sudden whole body cooling. Further, we determined if THC-002 could decrease expression of transient receptor potential melastatin 8 (TRPM8) channels associated with the cold responses. Hind leg skin temperature of female 10-week-old Sprague-Dawley rats was measured by thermal imaging. Experimental rats (n = 12) were given oral 100 mg/kg THC-002 daily for one week, and controls (n = 12) were similarly treated with THC-002-free solution. Afterwards, thermal imaging and cystometric investigations of the freely moving conscious rats were performed at room temperature (RT, 27 ± 2°C) for 20 min. The rats were then transferred to a low temperature (LT, 4 ± 2°C) environment during which thermal imaging and cystometric measurements were taken at 5, 10, 20, 30, and 40 min. Afterward, the skin tissues were harvested to estimate expression levels of TRPM8 channels by immunohistochemistry and real-time reverse-transcription polymerase chain reaction. The RT skin temperature of THC-002-treated rats was significantly higher than controls. During the first 20 min under LT, the control rats exhibited cold stress-induced detrusor overactivity such as decreased voiding interval and bladder capacity. THC-002 partially inhibited the detrusor overactivity patterns. During the second 20 min, skin temperature was relatively stable, and the detrusor overactivity of both groups slowly disappeared. THC-002 significantly reduced expression of TRPM8 channel protein and mRNA. THC-002 inhibited cold stress-induced detrusor overactivity resulting from decreasing skin temperature. Therefore, THC-002 might provide resistance to cold stress-exacerbated lower urinary tract symptoms. Copyright © 2012 Wiley Periodicals, Inc.
Gómez-Soriano, J; Goiriena, E; Florensa-Vila, J; Gómez-Arguelles, J M; Mauderli, A; Vierck, C J; Albu, S; Simón-Martinez, C; Taylor, J
2012-09-01
Case report of a 42-year-old woman with non-evoked pain diagnosed with a cavernous C7-Th6 spinal haemangioma. To assess the effect of intramedullary haemorrhage (IH) on nociception and neuropathic pain (NP) at and below an incomplete spinal cord injury (SCI). Sensorimotor Function Group, Hospital Nacional de Parapléjicos de Toledo (HNPT). T2*-susceptibility weighted image (SWI) magnetic resonance imaging (MRI) of spinal haemosiderin and a complete pain history were performed 8 months following initial dysaesthesia complaint. Thermal pain thresholds were assessed with short 1 s stimuli, while evidence for central sensitization was obtained with psychophysical electronic Visual Analogue Scale rating of tonic 10 s 3 °C and 48 °C stimuli, applied at and below the IH. Control data were obtained from 10 healthy volunteers recruited from the HNPT. Non-evoked pain was present within the Th6 dermatome and lower legs. T2*-SWI MRI imaging detected extensive haemosiderin-rich IH (C7-Th5/6 spinal level). Cold allodynia was detected below the IH (left L5 dermatome) with short thermal stimuli. Tonic thermal stimuli applied to the Th6, Th10 and C7 dermatomes revealed widespread heat and cold allodynia. NP was diagnosed following IH, corroborated by an increase in below-level cold pain threshold with at- and below-level cold and heat allodynia. Psychophysical evidence for at- and below-level SCI central sensitization was obtained with tonic thermal stimuli. Early detection of IH could lead to better management of specific NP symptoms, an appreciation of the role of haemorrhage as an aggravating SCI physical factor, and the identification of specific spinal pathophysiological pain mechanisms.
A Search for Cosmic String Loops Using GADGET-2 Cosmological N-Body Simulator
NASA Astrophysics Data System (ADS)
Braverman, William; Cousins, Bryce; Jia, Hewei
2018-01-01
Cosmic string loops are an extremely elusive hypothetical entity that have eluded the grasp of physicists and astronomers since their existence was postulated in the 1970’s. Finding evidence of their existence could be the first empirical evidence of string theory.Simulating their basic motion in a cold dark matter background using GADGET-2 allows us to predict where they may cluster during large scale structure formation (if they cluster at all). Here, we present our progress in placing cosmic strings into GADGET-2 with their basic equations of motion to lay a ground work for more complex simulations to find where these strings cluster. Ultimately, these simulations could lay a groundwork as to where future microlensing and gravitational wave observatories should look for cosmic strings.
Barber-Westin, Sue D; Noyes, Frank R
2017-12-01
Approximately two-thirds of anterior cruciate ligament (ACL) tears are sustained during noncontact situations when an athlete is cutting, pivoting, decelerating, or landing from a jump. Some investigators have postulated that fatigue may result in deleterious alterations in lower limb biomechanics during these activities that could increase the risk of noncontact ACL injuries. However, prior studies have noted a wide variation in fatigue protocols, athletic tasks studied, and effects of fatigue on lower limb kinetics and kinematics. First, to determine if fatigue uniformly alters lower limb biomechanics during athletic tasks that are associated with noncontact ACL injuries. Second, to determine if changes should be made in ACL injury prevention training programs to alter the deleterious effects of fatigue on lower limb kinetics and kinematics. Systematic review; Level of evidence, 4. A systematic review of the literature using MEDLINE was performed. Key terms were fatigue, neuromuscular, exercise, hop test, and single-legged function tests. Inclusion criteria were original research studies involving healthy participants, use of a fatigue protocol, study of at least 1 lower limb task that involved landing from a hop or jump or cutting, and analysis of at least 1 biomechanical variable. Thirty-seven studies involving 806 athletes (485 female, 321 male; mean age, 22.7 years) met the inclusion criteria. General fatigue protocols were used in 20 investigations, peripheral protocols were used in 17 studies, and 21 different athletic tasks were studied (13 single-legged, 8 double-legged). There was no consistency among investigations regarding the effects of fatigue on hip, knee, or ankle joint angles and moments or surface electromyography muscle activation patterns. The fatigue protocols typically did not produce statistically significant changes in ground-reaction forces. Published fatigue protocols did not uniformly produce alterations in lower limb neuromuscular factors that heighten the risk of noncontact ACL injuries. Therefore, justification does not currently exist for major changes in ACL injury prevention training programs to account for potential fatigue effects. However, the effect of fatigue related to ACL injuries is worthy of further investigation, including the refinement of protocols and methods of analysis.
Roberts, Llion A.; Figueiredo, Vandre C.; Egner, Ingrid; Krog, Simone; Aas, Sigve N.; Suzuki, Katsuhiko; Markworth, James F.; Coombes, Jeff S.; Cameron‐Smith, David; Raastad, Truls
2016-01-01
Key points Cold water immersion and active recovery are common post‐exercise recovery treatments. A key assumption about the benefits of cold water immersion is that it reduces inflammation in skeletal muscle. However, no data are available from humans to support this notion.We compared the effects of cold water immersion and active recovery on inflammatory and cellular stress responses in skeletal muscle from exercise‐trained men 2, 24 and 48 h during recovery after acute resistance exercise.Exercise led to the infiltration of inflammatory cells, with increased mRNA expression of pro‐inflammatory cytokines and neurotrophins, and the subcellular translocation of heat shock proteins in muscle. These responses did not differ significantly between cold water immersion and active recovery.Our results suggest that cold water immersion is no more effective than active recovery for minimizing the inflammatory and stress responses in muscle after resistance exercise. Abstract Cold water immersion and active recovery are common post‐exercise recovery treatments. However, little is known about whether these treatments influence inflammation and cellular stress in human skeletal muscle after exercise. We compared the effects of cold water immersion versus active recovery on inflammatory cells, pro‐inflammatory cytokines, neurotrophins and heat shock proteins (HSPs) in skeletal muscle after intense resistance exercise. Nine active men performed unilateral lower‐body resistance exercise on separate days, at least 1 week apart. On one day, they immersed their lower body in cold water (10°C) for 10 min after exercise. On the other day, they cycled at a low intensity for 10 min after exercise. Muscle biopsies were collected from the exercised leg before, 2, 24 and 48 h after exercise in both trials. Exercise increased intramuscular neutrophil and macrophage counts, MAC1 and CD163 mRNA expression (P < 0.05). Exercise also increased IL1β, TNF, IL6, CCL2, CCL4, CXCL2, IL8 and LIF mRNA expression (P < 0.05). As evidence of hyperalgesia, the expression of NGF and GDNF mRNA increased after exercise (P < 0.05). The cytosolic protein content of αB‐crystallin and HSP70 decreased after exercise (P < 0.05). This response was accompanied by increases in the cytoskeletal protein content of αB‐crystallin and the percentage of type II fibres stained for αB‐crystallin. Changes in inflammatory cells, cytokines, neurotrophins and HSPs did not differ significantly between the recovery treatments. These findings indicate that cold water immersion is no more effective than active recovery for reducing inflammation or cellular stress in muscle after a bout of resistance exercise. PMID:27704555
Peake, Jonathan M; Roberts, Llion A; Figueiredo, Vandre C; Egner, Ingrid; Krog, Simone; Aas, Sigve N; Suzuki, Katsuhiko; Markworth, James F; Coombes, Jeff S; Cameron-Smith, David; Raastad, Truls
2017-02-01
Cold water immersion and active recovery are common post-exercise recovery treatments. A key assumption about the benefits of cold water immersion is that it reduces inflammation in skeletal muscle. However, no data are available from humans to support this notion. We compared the effects of cold water immersion and active recovery on inflammatory and cellular stress responses in skeletal muscle from exercise-trained men 2, 24 and 48 h during recovery after acute resistance exercise. Exercise led to the infiltration of inflammatory cells, with increased mRNA expression of pro-inflammatory cytokines and neurotrophins, and the subcellular translocation of heat shock proteins in muscle. These responses did not differ significantly between cold water immersion and active recovery. Our results suggest that cold water immersion is no more effective than active recovery for minimizing the inflammatory and stress responses in muscle after resistance exercise. Cold water immersion and active recovery are common post-exercise recovery treatments. However, little is known about whether these treatments influence inflammation and cellular stress in human skeletal muscle after exercise. We compared the effects of cold water immersion versus active recovery on inflammatory cells, pro-inflammatory cytokines, neurotrophins and heat shock proteins (HSPs) in skeletal muscle after intense resistance exercise. Nine active men performed unilateral lower-body resistance exercise on separate days, at least 1 week apart. On one day, they immersed their lower body in cold water (10°C) for 10 min after exercise. On the other day, they cycled at a low intensity for 10 min after exercise. Muscle biopsies were collected from the exercised leg before, 2, 24 and 48 h after exercise in both trials. Exercise increased intramuscular neutrophil and macrophage counts, MAC1 and CD163 mRNA expression (P < 0.05). Exercise also increased IL1β, TNF, IL6, CCL2, CCL4, CXCL2, IL8 and LIF mRNA expression (P < 0.05). As evidence of hyperalgesia, the expression of NGF and GDNF mRNA increased after exercise (P < 0.05). The cytosolic protein content of αB-crystallin and HSP70 decreased after exercise (P < 0.05). This response was accompanied by increases in the cytoskeletal protein content of αB-crystallin and the percentage of type II fibres stained for αB-crystallin. Changes in inflammatory cells, cytokines, neurotrophins and HSPs did not differ significantly between the recovery treatments. These findings indicate that cold water immersion is no more effective than active recovery for reducing inflammation or cellular stress in muscle after a bout of resistance exercise. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Fabrication of Bi–Sb–Te Thermoelectric by Cold-Pressed Sintering for Motorcycle Exhaust.
Kao, Mu-Jung; Chen, Ming-Jing
2017-04-01
This study was conducted on the Bi–Sb–Te thermoelectric material which is cold-pressed Sintering under 750 Mpa to make square thermoelectric pairs with size 8.2 mm × 8.2 mm and thicknesses 0.8 mm and 1.5 mm. The zone melting method was used to acquire P-type thermoelectric material Bi0.4Sb1.6Te3 and N-type thermoelectric material Bi2Te2.5Se0.5. At temperature 383 K, the measured Seebeck coefficient of Bi0.4Sb1.6Te3 is 222 μV/K, and its thermoelectric figure of merit ZT is 1.35. At temperature 400 K, the measured Seebeck coefficient of Bi2Te2.5Se0.5 is 210 μV/K, and its thermoelectric figure of merit ZT is 1.13. Using Solder paste Sn42Bi58 and copper electrode plate are in series connection with 16 pieces of P/N thermoelectric material to form thermoelectric modules. The thermoelectric module is actually pasted on the motorcycle waste heat source to be evaluated the performance, making the cold-end temperature dissipation heat can enhance the temperature difference between it so as to increase the output power. Increasing the leg thickness of thermoelectric module and making the about 35 °C temperature-difference of those can obviously enhance the performance of in terms of its voltage, its thermoelectric figure of merit ZT and output power of the thermoelectric modules.
Pretest and posttest calculations of Semiscale Test S-07-10D with the TRAC computer program. [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duerre, K.H.; Cort, G.E.; Knight, T.D.
The Transient Reactor Analysis Code (TRAC) developed at the Los Alamos National Laboratory was used to predict the behavior of the small-break experiment designated Semiscale S-07-10D. This test simulates a 10 per cent communicative cold-leg break with delayed Emergency Core Coolant injection and blowdown of the broken-loop steam generator secondary. Both pretest calculations that incorporated measured initial conditions and posttest calculations that incorporated measured initial conditions and measured transient boundary conditions were completed. The posttest calculated parameters were generally between those obtained from pretest calculations and those from the test data. The results are strongly dependent on depressurization rate and,more » hence, on break flow.« less
Delaforge, Aurélie; Suárez-Morales, Eduardo; Walkusz, Wojciech; Karley Campbell; Mundy, C J
2017-01-01
A new species of monstrilloid copepod, Monstrillopsis planifrons sp. n. , is described from an adult female that was collected beneath snow-covered sea ice during the 2014 Ice Covered Ecosystem - CAMbridge bay Process Study (ICE-CAMPS) in Dease Strait of the Canadian Arctic Archipelago. Currently, up to six species of this order are known to occur in polar latitudes. The new species described herein shares similarities with Monstrillopsis dubia (Scott, 1904) but differs in its body proportions and cephalothorax ornamentation; the cephalothorax is covered by minute scattered papillae on dorsal and ventral surfaces; this species has a reduced fifth leg endopod, fifth leg exopod armed with three setae, antennule with fused segments 3-4, and the genital double-somite bears unique posterolateral processes. This is the second species of this genus recorded in the Arctic, after Monstrillopsis ferrarii (Suárez-Morales & Ivanenko, 2004), described from the White Sea, and is the first record of Monstrillopsis in Canadian waters. With the addition of this new species and the recognition of Monstrillopsis bernardensis comb. nov. as a member of this genus, the number of nominal species is now 15. Overall, this genus has a tendency to be distributed in temperate and cold waters, while only three species have been found in tropical and subtropical latitudes.
Rapid morphological change in living humans: implications for modern human origins.
Bogin, Barry; Rios, Luis
2003-09-01
Human body size and body proportions are interpreted as markers of ethnicity, 'race,' adaptation to temperature, nutritional history and socioeconomic status. Some studies emphasize only one of these indicators and other studies consider combinations of indicators. To better understand the biocultural nature of human size and proportions a new study of the growth of Maya-American youngsters was undertaken in 1999 and 2000. One purpose of this research is to assess changes in body proportion between Maya growing up in the US and Maya growing up in Guatemala. Height and sitting height of 6-12-year-old boys and girls (n=360) were measured and the sitting height ratio [sitting height/height]x100, a measure of proportion, was calculated. These data are compared with a sample of Maya of the same ages living in Guatemala and measured in 1998 (n=1297). Maya-American children are currently 10.24 cm taller, on average, and have a significantly lower sitting height ratio, (i.e. relatively longer legs, averaging 7.02 cm longer) than the Guatemala Maya. Maya-American children have body proportions more like those of white children in the US than like Maya children in Guatemala. Improvements in the environment for growth, in terms of nutrition and health, seem to explain both the trends in greater stature and relatively longer legs for the Maya-Americans. These findings are applied to the problem of modern human origins as assessed from fossil skeletons. It has been proposed that heat adapted, relatively long-legged Homo sapiens from Africa replaced the cold adapted, relatively short-legged Homo neandertalensis of the Levant and Europe [J Hum Evol 32 (1997a) 423]. Skeletal samples of Maya adults from rural Guatemala have body proportions similar to adult Neandertals and to skeletal samples from Europe with evidence of nutritional and disease stress. Just as nutrition and health status explains the differences in the body proportions of living Maya children, these factors, along with adaptation to climate, may also explain much of the differences between the Neandertal and African hominid samples.
SOLAR MAGNETIZED TORNADOES: ROTATIONAL MOTION IN A TORNADO-LIKE PROMINENCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Yang; Veronig, Astrid; Temmer, Manuela
Su et al. proposed a new explanation for filament formation and eruption, where filament barbs are rotating magnetic structures driven by underlying vortices on the surface. Such structures have been noticed as tornado-like prominences when they appear above the limb. They may play a key role as the source of plasma and twist in filaments. However, no observations have successfully distinguished rotational motion of the magnetic structures in tornado-like prominences from other motions such as oscillation and counter-streaming plasma flows. Here we report evidence of rotational motions in a tornado-like prominence. The spectroscopic observations in two coronal lines were obtainedmore » from a specifically designed Hinode/EIS observing program. The data revealed the existence of both cold and million-degree-hot plasma in the prominence leg, supporting the so-called prominence-corona transition region. The opposite velocities at the two sides of the prominence and their persistent time evolution, together with the periodic motions evident in SDO/AIA dark structures, indicate a rotational motion of both cold and hot plasma with a speed of ∼5 km s{sup –1}.« less
Effects of immersion in cool water on lung-exhaled nitric oxide at rest and during exercise
NASA Technical Reports Server (NTRS)
Pendergast, D. R.; Krasney, J. A.; DeRoberts, D.; Farhi, L. E. (Principal Investigator)
1999-01-01
Lung nitric oxide (NO) has been postulated to relax airway and vascular smooth muscle at rest and during exercise. As a cold environment is a common cause of respiratory distress, lung exhaled NO was measured during skin and core body cooling at rest and during a progressive cycle exercise. Ten healthy male subjects were immersed in water at a water temperature (Tw) which was thermal neutral (35 degrees C) at 30 degrees C Tw, at which only skin temperature is decreased; and at 20 degrees C Tw, at which the core temperature is decreased (0.05 degrees C). At rest, V(O), and V(E) increased while exhaled NO concentration [NO] and the rate of expiration of NO (V(NO)) decreased with decreased Tw. V(O2) and ventilation (V(E)) increased with workload (W) and the values at all Tw were not different, whereas, [NO] decreased with W and the values during exercise were progressively less at all Ws as Tw declined. These results indicate that lung NO output is reduced in a graded fashion during body cooling at rest and during exercise. This suggests that lower lung NO may contribute to airway obstruction in cold environments and NO may contribute to regulation of lung heat and water exchange.
EEG during pedaling: Evidence for cortical control of locomotor tasks
Jain, Sanket; Gourab, Krishnaj; Schindler-Ivens, Sheila; Schmit, Brian D.
2014-01-01
Objective This study characterized the brain electrical activity during pedaling, a locomotor-like task, in humans. We postulated that phasic brain activity would be associated with active pedaling, consistent with a cortical role in locomotor tasks. Methods Sixty four channels of electroencephalogram (EEG) and 10 channels of electromyogram (EMG) data were recorded from 10 neurologically-intact volunteers while they performed active and passive (no effort) pedaling on a custom-designed stationary bicycle. Ensemble averaged waveforms, 2 dimensional topographic maps and amplitude of the β (13–35 Hz) frequency band were analyzed and compared between active and passive trials. Results The peak-to-peak amplitude (peak positive–peak negative) of the EEG waveform recorded at the Cz electrode was higher in the passive than the active trials (p < 0.01). β-band oscillations in electrodes overlying the leg representation area of the cortex were significantly desynchronized during active compared to the passive pedaling (p < 0.01). A significant negative correlation was observed between the average EEG waveform for active trials and the composite EMG (summated EMG from both limbs for each muscle) of the rectus femoris (r = −0.77, p < 0.01) the medial hamstrings (r = −0.85, p < 0.01) and the tibialis anterior (r = −0.70, p < 0.01) muscles. Conclusions These results demonstrated that substantial sensorimotor processing occurs in the brain during pedaling in humans. Further, cortical activity seemed to be greatest during recruitment of the muscles critical for transitioning the legs from flexion to extension and vice versa. Significance This is the first study demonstrating the feasibility of EEG recording during pedaling, and owing to similarities between pedaling and bipedal walking, may provide valuable insight into brain activity during locomotion in humans. PMID:23036179
Intratester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.
Brindle, Richard A; Ebaugh, David; Milner, Clare E
2018-06-06
Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a "break" test, the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intrarater reliability and construct validity of a hip abductor eccentric strength test. Intrarater reliability and construct validity study. Twenty healthy adults (26 [6] y; 1.66 [0.06] m; 62.2 [8.0] kg) made 2 visits to the laboratory at least 1 week apart. During the hip abductor eccentric strength test, a handheld dynamometer recorded peak force and time to peak force, and limb position was recorded via a motion capture system. Intrarater reliability was determined using intraclass correlation, SEM, and minimal detectable difference. Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a 1-sample t test. The hip abductor eccentric strength test had substantial intrarater reliability (intraclass correlation (3,3) = .88; 95% confidence interval, .65-.95), SEM of 0.9 %BWh, and a minimal detectable difference of 2.5 %BWh. Construct validity was established as peak force occurred 2.1 (0.6) seconds (range: 0.7-3.7 s) after the start of the lowering phase of the test (P ≤ .001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.
Exercise does not produce hypoalgesia when performed immediately after a painful stimulus.
Gajsar, Hannah; Nahrwold, Katharina; Titze, Christina; Hasenbring, Monika I; Vaegter, Henrik B
2018-04-25
Exercise-induced hypoalgesia (EIH) and conditioned pain modulation (CPM) are assumed to reflect descending pain inhibition. Potential interactions between EIH and CPM may be important in the therapy of chronic pain, as reduced CPM and increased pain after exercise are frequently observed. This study compared the EIH response after CPM was activated using a cold pressor task with the EIH response after a control condition. Thirty-one participants (age: 27.7±9.8; 15 female) completed two sessions: a cold pressor task (CPT) session, i.e. testing EIH with preceding CPM activation induced using a 2 min CPT at approximately 2°C, and a control session, i.e. testing EIH after a control condition (2 min of quiet rest). EIH was induced using a 15 min bicycling exercise at a target heart rate corresponding to 75% VO2 max. Repeated measures ANOVAs on pressure pain thresholds (PPTs) at the hand, back and leg were used to determine the effects of exercise after the cold pressor test and control condition. Furthermore, correlations between CPM and EIH, in the CPT session as well as control session, were calculated at each assessment site. A significant time x condition interaction (F(1, 30)=43.61, p<0.001, partial η2=0.59), with Bonferroni-corrected post-hoc t-tests showed that PPTs increased after exercise in the control session (p<0.001), but not in the CPT session (p=0.125). Furthermore, there was a small positive correlation of EIH in the control session and CPM at the hand (r=0.37, p=0.043). There was a moderate negative correlation of EIH in the CPT session and CPM at the hand (r=-0.50, p=0.004), and smaller negative correlations at the back (r=-0.37, p=0.036) and at the leg (r=-0.35, p=0.054). Attenuated EIH after the CPM activation in comparison to a control condition suggests that EIH and CPM may share underlying pain inhibitory mechanisms on a systemic level. This assumption is further supported by the finding of small to moderate significant correlations between EIH and CPM at the hand. The attenuated EIH response furthermore suggests that these mechanisms are exhaustible, i.e. that its effects decline after a certain amount of inhibition. In patients with chronic pain, assessing the current capacity of the descending pain inhibitory system - as indicated by the CPM response - may aid to make better predictions about how patients will respond to exercise with respect to acute pain reduction.
Disruptive technologies and force transformation: a Canadian perspective (Keynote Address)
NASA Astrophysics Data System (ADS)
Moen, Ingar O.; Walker, Robert S.
2005-05-01
Transformation of Canada"s military forces is being pursued to ensure their relevancy and impact in light of the new defence and security environment. This environment is characterized by an increasingly complex spectrum of military operations spanning pre- and post-conflict, the emergence of an asymmetric threat that differs substantially from the peer-on-peer threat of the Cold War, and the globalization of science and technology. Disruptive technologies - those that have a profound impact on established practice - are increasingly shaping both the civil and military sectors, with advances in one sector now regularly seeding disruptions in the other. This paper postulates the likely sources of disruptive technologies over the next 10-20 years. It then looks at how science and technology investments can contribute to force transformation either to take advantage of or mitigate the effects of these disruptions.
Hexagonal comb cells of honeybees are not produced via a liquid equilibrium process
NASA Astrophysics Data System (ADS)
Bauer, Daniel; Bienefeld, Kaspar
2013-01-01
The nests of European honeybees ( Apis mellifera) are organised into wax combs that contain many cells with a hexagonal structure. Many previous studies on comb-building behaviour have been made in order to understand how bees produce this geometrical structure; however, it still remains a mystery. Direct construction of hexagons by bees was suggested previously, while a recent hypothesis postulated the self-organised construction of hexagonal comb cell arrays; however, infrared and thermographic video observations of comb building in the present study failed to support the self-organisation hypothesis because bees were shown to be engaged in direct construction. Bees used their antennae, mandibles and legs in a regular sequence to manipulate the wax, while some bees supported their work by actively warming the wax. During the construction of hexagonal cells, the wax temperature was between 33.6 and 37.6 °C. This is well below 40 °C, i.e. the temperature at which wax is assumed to exist in the liquid equilibrium that is essential for self-organised building.
Buscemi, Charles P; Romeo, CarolAnn
2014-01-01
The effects of multiple medications may impair or enhance wound healing. A review of the literature for drug side effects identified cell culture and case studies of angiotensin-converting enzyme inhibitors (ACEIs) impairing collagen deposition in cutaneous wounds; these medications have also been used to prevent or minimize keloid formation. A 71-year-old male patient presented with a venous leg ulcer (VLU), having incurred a crushing injury and fracture requiring surgical repair 16 years earlier. The patient's history was significant for obesity, smoking 1 cigar daily, hypertension, and lower extremity venous insufficiency; medications included amlodipine and lisinopril. The wound initially responded well to advanced wound products and compression, but wound healing subsequently stalled. A collagen-containing alginate dressing was added to the treatment regimen and the wound closed within 2 weeks. We postulate that lisinopril may have contributed to the observed delayed healing and targeted this potential impediment to wound healing with a readily available topical collagen-containing product resulting in a rapid wound closure after a significant delay in progress toward wound healing.
Elshoff, Jan-Peer; Timmermann, Lars; Schmid, Miriam; Arth, Christoph; Komenda, Michael; Brunnert, Marcus; Bauer, Lars
2013-12-01
Rotigotine transdermal patch is approved for the treatment of early and advanced idiopathic Parkinson's disease (PD) and moderate-to-severe idiopathic restless legs syndrome (RLS). A cold chain manufacturing and distribution process was temporarily implemented in 2008, as this reduced the crystal formation reported within patches stored at room temperature. In order to overcome the crystallization issue and meet EMA and FDA requirements, a new room temperature stable formulation was developed. The three studies reported here were conducted to determine whether the new room temperature stable patch demonstrated similar bioavailability and adhesiveness to the original and intermediate patches. Data are reported from three cross-over studies that compared the original, cold chain and room temperature stable patch. Two open-label bioequivalence studies investigated the 2 mg/24 h dosage in healthy individuals (SP951, n = 52 [Clinicaltrials.gov: NCT00881894]; SP0987, n = 50 [NCT01059903]) and a double-blind patch adhesiveness study investigated the 8 mg/24 h dosage in patients with PD (SP1066, n = 56 [NCT01338896]). Plasma concentration-time curves and geometric means for pharmacokinetic parameters were similar for the cold chain vs. original patch in SP951 (AUC(0-tz): 2.68 vs. 2.71 ng/mL*h; point estimate: 0.99 [90% confidence interval (CI): 0.91, 1.07]) (Cmax: 0.131 vs. 0.136 ng/mL; 0.96 [0.89, 1.04]) and for the room temperature stable vs. cold chain patch in SP0987 (AUC(0-tz): 4.51 vs. 4.87 ng/mL*h; 0.90 [0.84, 0.97]) (Cmax: 0.23 vs. 0.23 ng/mL; 0.95 [0.88, 1.02]). In both studies, 90% CIs for ratios of AUC(0-tz) and Cmax were within the bioequivalence acceptance range (0.8-1.25). In SP1066, overall median adhesiveness scores were similar for cold chain (0.5 [range: 0-4]) and room temperature stable (0 [0-4]) formulations. These results demonstrated bioequivalence and indicated similar adhesiveness of the approved room temperature stable rotigotine patch with the original and cold chain patches. Potential limitations include the enrolment of healthy volunteers in the bioequivalence studies, as these individuals were likely to be younger than the general PD or RLS population.
Isolated core vs. superficial cooling effects on virtual maze navigation.
Payne, Jennifer; Cheung, Stephen S
2007-07-01
Cold impairs cognitive performance and is a common occurrence in many survival situations. Altered behavior patterns due to impaired navigation abilities in cold environments are potential problems in lost-person situations. We investigated the separate effects of low core temperature and superficial cooling on a spatially demanding virtual navigation task. There were 12 healthy men who were passively cooled via 15 degrees C water immersion to a core temperature of 36.0 degrees C, then transferred to a warm (40 degrees C) water bath to eliminate superficial shivering while completing a series of 20 virtual computer mazes. In a control condition, subjects rested in a thermoneutral (approximately 35 degrees C) bath for a time-matched period before being transferred to a warm bath for testing. Superficial cooling and distraction were achieved by whole-body immersion in 35 degree water for a time-matched period, followed by lower leg immersion in 10 degree C water for the duration of the navigational tests. Mean completion time and mean error scores for the mazes were not significantly different (p > 0.05) across the core cooling (16.59 +/- 11.54 s, 0.91 +/- 1.86 errors), control (15.40 +/- 8.85 s, 0.82 +/- 1.76 errors), and superficial cooling (15.19 +/- 7.80 s, 0.77 +/- 1.40 errors) conditions. Separately reducing core temperature or increasing cold sensation in the lower extremities did not influence performance on virtual computer mazes, suggesting that navigation is more resistive to cooling than other, simpler cognitive tasks. Further research is warranted to explore navigational ability at progressively lower core and skin temperatures, and in different populations.
Delaforge, Aurélie; Suárez-Morales, Eduardo; Walkusz, Wojciech; Karley Campbell; Mundy, C. J.
2017-01-01
Abstract A new species of monstrilloid copepod, Monstrillopsis planifrons sp. n., is described from an adult female that was collected beneath snow-covered sea ice during the 2014 Ice Covered Ecosystem – CAMbridge bay Process Study (ICE-CAMPS) in Dease Strait of the Canadian Arctic Archipelago. Currently, up to six species of this order are known to occur in polar latitudes. The new species described herein shares similarities with Monstrillopsis dubia (Scott, 1904) but differs in its body proportions and cephalothorax ornamentation; the cephalothorax is covered by minute scattered papillae on dorsal and ventral surfaces; this species has a reduced fifth leg endopod, fifth leg exopod armed with three setae, antennule with fused segments 3–4, and the genital double-somite bears unique posterolateral processes. This is the second species of this genus recorded in the Arctic, after Monstrillopsis ferrarii (Suárez-Morales & Ivanenko, 2004), described from the White Sea, and is the first record of Monstrillopsis in Canadian waters. With the addition of this new species and the recognition of Monstrillopsis bernardensis comb. nov. as a member of this genus, the number of nominal species is now 15. Overall, this genus has a tendency to be distributed in temperate and cold waters, while only three species have been found in tropical and subtropical latitudes. PMID:29118635
The Humboldt Penguin (Spheniscus humboldti) Rete Tibiotarsale - A supreme biological heat exchanger.
Kazas, Shaked; Benelly, Moran; Golan, Saar
2017-07-01
Humans are unable to survive low temperature environments without custom designed clothing and support systems. In contrast, certain penguin species inhabit extremely cold climates without losing substantial energy to self-heating (emperor penguins ambient temperature plummets to as low as -45°C). Penguins accomplish this task by relying on distinct anatomical, physiological and behavioral adaptations. One such adaptation is a blood vessel heat exchanger called the 'Rete Tibiotarsale' - an intermingled network of arteries and veins found in penguins' legs. The Rete existence results in blood occupying the foot expressing a lower average temperature and thus the penguin loosing less heat to the ground. This study examines the Rete significance for the species thermal endurance. The penguin anatomy (leg and main blood vessels) is reconstructed using data chiefly based on the Humboldt species. The resulting model is thermally analyzed using finite element (COMSOL) with the species environment used as boundary conditions. A human-like blood vessel configuration, scaled to the penguin's dimensions, is used as a control for the study. Results indicate that the Rete existence facilitates upkeep of 25-65% of the species total metabolic energy production as compared with the human-like configuration; thus making the Rete probably crucial for penguin thermal endurance. Here, we quantitatively link for the first time the function and structure of this remarkable physiological phenotype. Copyright © 2017 Elsevier Ltd. All rights reserved.
Clinical use of cold atmospheric pressure argon plasma in chronic leg ulcers: A pilot study.
Ulrich, C; Kluschke, F; Patzelt, A; Vandersee, S; Czaika, V A; Richter, H; Bob, A; Hutten, J von; Painsi, C; Hüge, R; Kramer, A; Assadian, O; Lademann, J; Lange-Asschenfeldt, B
2015-05-01
In the age of multiresistant microbes and the increasing lack of efficient antibiotics, conventional antiseptics play a critical role in the prevention and therapy of wound infections. Recent studies have demonstrated the antiseptic effects of cold atmospheric pressure plasma (APP). In this pilot, study we investigate the overall suitability of one of the first APP sources for wound treatment focusing on its potential antimicrobial effects. The wound closure rate and the bacterial colonisation of the wounds were investigated. Patients suffering from chronic leg ulcers were treated in a clinical controlled monocentric trial with either APP or octenidine (OCT). In patients who presented with more than one ulceration in different locations, one was treated with APP and the other one with OCT. Each group was treated three times a week over a period of two weeks. The antimicrobial efficacy was evaluated immediately after and following two weeks of treatment. Wounds treated with OCT showed a significantly higher microbial reduction (64%) compared to wounds treated with APP (47%) immediately after the treatment. Over two weeks of antiseptic treatment the bacterial density was reduced within the OCT group (-35%) compared to a slight increase in bacterial density in the APP-treated group (+12%). Clinically, there were no signs of delayed wound healing observed in either group and both treatments were well tolerated. The immediate antimicrobial effects of the APP prototype source were almost comparable to OCT without any signs of cytotoxicity. This pilot study is limited by current configurations of the plasma source, where the narrow plasma beam made it difficult to cover larger wound surface areas and in order to avoid untreated areas of the wound bed, smaller wounds were assigned to the APP-treatment group. This limits the significance of AAP-related effects on the wound healing dynamics, as smaller wounds tend to heal faster than larger wounds. However, clinical wound healing studies on a larger scale now seem justifiable. A more advanced plasma source prototype allowing the treatment of larger wounds will address APP's influence on healing dynamics, synergetic treatment with current antiseptics and effects on multiresistant bacteria.
Rapid short-term cooling following the Chicxulub impact at the Cretaceous–Paleogene boundary
Vellekoop, Johan; Sluijs, Appy; Smit, Jan; Schouten, Stefan; Weijers, Johan W. H.; Sinninghe Damsté, Jaap S.; Brinkhuis, Henk
2014-01-01
The mass extinction at the Cretaceous–Paleogene boundary, ∼66 Ma, is thought to be caused by the impact of an asteroid at Chicxulub, present-day Mexico. Although the precise mechanisms that led to this mass extinction remain enigmatic, most postulated scenarios involve a short-lived global cooling, a so-called “impact winter” phase. Here we document a major decline in sea surface temperature during the first months to decades following the impact event, using TEX86 paleothermometry of sediments from the Brazos River section, Texas. We interpret this cold spell to reflect, to our knowledge, the first direct evidence for the effects of the formation of dust and aerosols by the impact and their injection in the stratosphere, blocking incoming solar radiation. This impact winter was likely a major driver of mass extinction because of the resulting global decimation of marine and continental photosynthesis. PMID:24821785
Molecular Regulation of Parturition: The Role of the Decidual Clock.
Norwitz, Errol R; Bonney, Elizabeth A; Snegovskikh, Victoria V; Williams, Michelle A; Phillippe, Mark; Park, Joong Shin; Abrahams, Vikki M
2015-04-27
The timing of birth is a critical determinant of perinatal outcome. Despite intensive research, the molecular mechanisms responsible for the onset of labor both at term and preterm remain unclear. It is likely that a "parturition cascade" exists that triggers labor at term, that preterm labor results from mechanisms that either prematurely stimulate or short-circuit this cascade, and that these mechanisms involve the activation of proinflammatory pathways within the uterus. It has long been postulated that the fetoplacental unit is in control of the timing of birth through a "placental clock." We suggest that it is not a placental clock that regulates the timing of birth, but rather a "decidual clock." Here, we review the evidence in support of the endometrium/decidua as the organ primarily responsible for the timing of birth and discuss the molecular mechanisms that prime this decidual clock. Copyright © 2015 Cold Spring Harbor Laboratory Press; all rights reserved.
Using the Moon As A Low-Noise Seismic Detector For Strange Quark Nuggets
NASA Technical Reports Server (NTRS)
Banerdt, W. Bruce; Chui, Talso; Griggs, Cornelius E.; Herrin, Eugene T.; Nakamura, Yosio; Paik, Ho Jung; Penanen, Konstantin; Rosenbaum, Doris; Teplitz, Vigdor L.; Young, Joseph
2006-01-01
Strange quark matter made of up, down and strange quarks has been postulated by Witten [1]. Strange quark matter would be nearly charge neutral and would have density of nuclear matter (10(exp 14) gm/cu cm). Witten also suggested that nuggets of strange quark matter, or strange quark nuggets (SQNs), could have formed shortly after the Big Bang, and that they would be viable candidates for cold dark matter. As suggested by de Rujula and Glashow [2], an SQN may pass through a celestial body releasing detectable seismic energy along a straight line. The Moon, being much quieter seismically than the Earth, would be a favorable place to search for such events. We review previous searches for SQNs to illustrate the parameter space explored by using the Moon as a low-noise detector of SQNs. We also discuss possible detection schemes using a single seismometer, and using an International Lunar Seismic Network.
Robotic Lunar Lander Development Status
NASA Technical Reports Server (NTRS)
Ballard, Benjamin; Cohen, Barbara A.; McGee, Timothy; Reed, Cheryl
2012-01-01
NASA Marshall Space Flight Center and John Hopkins University Applied Physics Laboratory have developed several mission concepts to place scientific and exploration payloads ranging from 10 kg to more than 200 kg on the surface of the moon. The mission concepts all use a small versatile lander that is capable of precision landing. The results to date of the lunar lander development risk reduction activities including high pressure propulsion system testing, structure and mechanism development and testing, and long cycle time battery testing will be addressed. The most visible elements of the risk reduction program are two fully autonomous lander flight test vehicles. The first utilized a high pressure cold gas system (Cold Gas Test Article) with limited flight durations while the subsequent test vehicle, known as the Warm Gas Test Article, utilizes hydrogen peroxide propellant resulting in significantly longer flight times and the ability to more fully exercise flight sensors and algorithms. The development of the Warm Gas Test Article is a system demonstration and was designed with similarity to an actual lunar lander including energy absorbing landing legs, pulsing thrusters, and flight-like software implementation. A set of outdoor flight tests to demonstrate the initial objectives of the WGTA program was completed in Nov. 2011, and will be discussed.
NASA's Robotic Lunar Lander Development Program
NASA Technical Reports Server (NTRS)
Ballard, Benjamin W.; Reed, Cheryl L. B.; Artis, David; Cole, Tim; Eng, Doug S.; Kubota, Sanae; Lafferty, Paul; McGee, Timothy; Morese, Brian J.; Chavers, Gregory;
2012-01-01
NASA Marshall Space Flight Center and the Johns Hopkins University Applied Physics Laboratory have developed several mission concepts to place scientific and exploration payloads ranging from 10 kg to more than 200 kg on the surface of the moon. The mission concepts all use a small versatile lander that is capable of precision landing. The results to date of the lunar lander development risk reduction activities including high pressure propulsion system testing, structure and mechanism development and testing, and long cycle time battery testing will be addressed. The most visible elements of the risk reduction program are two fully autonomous lander flight test vehicles. The first utilized a high pressure cold gas system (Cold Gas Test Article) with limited flight durations while the subsequent test vehicle, known as the Warm Gas Test Article, utilizes hydrogen peroxide propellant resulting in significantly longer flight times and the ability to more fully exercise flight sensors and algorithms. The development of the Warm Gas Test Article is a system demonstration and was designed with similarity to an actual lunar lander including energy absorbing landing legs, pulsing thrusters, and flight-like software implementation. A set of outdoor flight tests to demonstrate the initial objectives of the WGTA program was completed in Nov. 2011, and will be discussed.
Guevara-López, Uriah; Gutiérrez-Sougarret, Bernardo; López-Pavón, Lucy; Aldrete, J Antonio; Tamayo-Valenzuela, Antonio
2004-01-01
Neuropathic pain results from injury or impairment of the nervous system manifested by pain syndrome. Experimental models have been used to study its effects and how to suppress these. Tricyclic antidepressants (TCA) and anticonvulsant (AC) have been used for treatment. To evaluate the antihyperanalgesic efficiency of intraperitoneal (IP) chlorimipramine (CIP) vs IP phenytoine (DFH) for induced neuropathic pain in an experimental animal model. After making a surgical ligature of the sciatic nerve in the right leg of 18 male rats, the time of withdrawal of both claws immersed in hot (45 degrees C) and cold water (10 degrees C) was measured during a four week period before and after IP CIP, DFH, or placebo administered in a double blind study. Significant statistical differences were observed in the time of withdrawal with CIP as compared with DFH and when both groups were compared with placebo (as tested by the paw immersion in hot water). When the thermal stimulus was cold water, an increase of the time of withdrawal was seen with DFH. These findings suggest that CIP and FS are both effective in the treatment of neuropathic pain in an animal model, as well as for the treatment of secondary hiperalgesia.
Effects of three postexercice recovery treatments on femoral artery blood flow kinetics.
Ménétrier, A; Mourot, L; Degano, B; Bouhaddi, M; Walther, G; Regnard, J; Tordi, N
2015-04-01
This study aimed to compare the kinetics of muscle leg blood flow during three recovery treatments following a prolonged exercise: contrast water therapy (CWT), compression stockings (CS) or passive recovery (PR). Fifteen men came to the laboratory three times to perform a 45-min exercise followed 5 min after by a standardized 12-min recovery treatment in upright position, alternating between two vats every 2 min: CWT (cold: ~12 °C to warm: 36 °C), CS (~20 mmHg) or PR. The order of treatments was randomized. Blood flow was measured using Doppler ultrasound during the recovery treatments (i.e., min 3, 5, 7 and 9) in the superficial femoral artery distally to the common bifurcation (~3 cm) (above the water and stocking). Blood flow was significantly higher during CWT (P<0.01; +22.91%) and CS (P<0.05; +15.26%) than during PR. Although no statistical difference between CWT and CS was observed, effect sizes were larger during CWT (large) than during CS (moderate). No changes in blood flow occurred in the femoral artery between hot and cold transitions of CWT. During immediate recovery of a high intensity exercise, CWT and CS trigger higher femoral artery blood flow than PR. Moreover, effect sizes were greater during CWT than during CS.
van der Harst, J J; Gokeler, A; Hof, A L
2007-07-01
Anterior cruciate ligament (ACL) deficiency can be a major problem for athletes and subsequent reconstruction of the ACL may be indicated if a conservative regimen has failed. After ACL reconstruction signs of abnormality in the use of the leg remain for a long time. It is expected that the landing after a single-leg hop for distance (horizontal hop) might give insight in the differences in kinematics and kinetics between uninjured legs and ACL-reconstructed legs. Before the ACL-reconstructed leg can be compared with the contralateral leg, knowledge of differences between legs of uninjured subjects is needed. Kinematic and kinetic variables of both legs were measured with an optoelectronic system and a force plate and calculated by inverse dynamics. The dominant leg (the leg with biggest horizontal hop distance) and the contralateral leg of nine uninjured subjects were compared. No significant differences were found in most of the kinematic and kinetic variables between dominant leg and contralateral leg of uninjured subjects. Only hop distance and hip extension angles differed significantly. This study suggests that there are no important differences between dominant leg and contralateral leg in healthy subjects. As a consequence, the uninvolved leg of ACL-reconstructed patients can be used as a reference. The observed variables of this study can be used as a reference of normal values and normal differences between legs in healthy subjects.
Does a crouched leg posture enhance running stability and robustness?
Blum, Yvonne; Birn-Jeffery, Aleksandra; Daley, Monica A; Seyfarth, Andre
2011-07-21
Humans and birds both walk and run bipedally on compliant legs. However, differences in leg architecture may result in species-specific leg control strategies as indicated by the observed gait patterns. In this work, control strategies for stable running are derived based on a conceptual model and compared with experimental data on running humans and pheasants (Phasianus colchicus). From a model perspective, running with compliant legs can be represented by the planar spring mass model and stabilized by applying swing leg control. Here, linear adaptations of the three leg parameters, leg angle, leg length and leg stiffness during late swing phase are assumed. Experimentally observed kinematic control parameters (leg rotation and leg length change) of human and avian running are compared, and interpreted within the context of this model, with specific focus on stability and robustness characteristics. The results suggest differences in stability characteristics and applied control strategies of human and avian running, which may relate to differences in leg posture (straight leg posture in humans, and crouched leg posture in birds). It has been suggested that crouched leg postures may improve stability. However, as the system of control strategies is overdetermined, our model findings suggest that a crouched leg posture does not necessarily enhance running stability. The model also predicts different leg stiffness adaptation rates for human and avian running, and suggests that a crouched avian leg posture, which is capable of both leg shortening and lengthening, allows for stable running without adjusting leg stiffness. In contrast, in straight-legged human running, the preparation of the ground contact seems to be more critical, requiring leg stiffness adjustment to remain stable. Finally, analysis of a simple robustness measure, the normalized maximum drop, suggests that the crouched leg posture may provide greater robustness to changes in terrain height. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dienes, Zoltan; Hutton, Sam
2013-02-01
According to the cold control theory of hypnosis (Dienes and Perner, 2007), hypnotic response occurs because of inaccurate higher order thoughts of intending. The dorsolateral prefrontal cortex (DLPFC) is a region likely involved in constructing accurate higher order thoughts. Thus, disrupting DLPFC with low frequency repetitive transcranial magnetic stimulation (rTMS) should make it harder to be aware of intending to perform an action. That is, it should be easier to respond to a hypnotic suggestion. Twenty-four medium hypnotisable subjects received low frequency rTMS to the left DLPFC and to a control site, the vertex, in counterbalanced order. The hypnotist was blind to which site had been stimulated. Subjects rated how strongly they expected to respond to each suggestion, and gave ratings on a 0-5 scale of the extent to which they experienced the response, for four suggestions (magnetic hands, arm levitation, rigid arm and taste hallucination). The experimenter also rated behavioural response. Low frequency rTMS to the DLPFC rather than vertex increased the degree of combined behavioural and subjective response. Further, subjects did not differ in their expectancy that they would respond in the two conditions, so the rTMS had an effect on hypnotic response above and beyond expectancies. The results support theories, including cold control theory, postulating a component of hypofrontality in hypnotic response. Copyright © 2012 Elsevier Ltd. All rights reserved.
Assessing the Institution of the Nuclear Nonproliferation Regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toomey, Christopher
2010-05-14
The nuclear nonproliferation regime is facing a crisis of effectiveness. During the Cold War, the regime was relatively effective in stemming the proliferation of nuclear weapons and building an institutional structure that could, under certain conditions, ensure continued success. However, in the evolving global context, the traditional approaches are becoming less appropriate. Globalization has introduced new sets of stresses on the nonproliferation regime, such as the rise of non-state actors, broadening extensity and intensity of supply chains, and the multipolarization of power. This evolving global context demands an analytical and political flexibility in order to meet future threats. Current institutionalmore » capabilities established during the Cold War are now insufficient to meet the nonproliferation regime’s current and future needs. The research was based on information gathered through interviews and reviews of the relevant literature, and two dominant themes emerged. First, that human security should be integrated into the regime to account for the rise of non-state actors and networked violence. Second, confidence in the regime’s overall effectiveness has eroded at a time where verification-based confidence is becoming more essential. The research postulates that a critical analysis of the regime that fully utilizes institutional theory, with its focus on rules, normative structures, and procedures will be essential to adapting the regime to the current global context, building mechanisms for generating trust, creating better enforcement, and providing flexibility for the future.« less
Estimating Surface and Subsurface Ice Abundance on Mercury Using a Thermophysical Model
NASA Astrophysics Data System (ADS)
Rubanenko, L.; Mazarico, E.; Neumann, G. A.; Paige, D. A.
2016-12-01
The small obliquity of the Moon and Mercury causes some topographic features near their poles to cast permanent shadows for geologic time periods. In the past, these permanently shadowed regions (PSRs) were found to have low enough temperatures to trap surface and subsurface water ice. On Mercury, high normal albedo is correlated with maximum temperatures <100 m and high radar backscatter, possibly indicating the presence of surface ice. Areas with slightly higher maximum temperatures were measured to have a decreased albedo, postulated to contain of organic materials overlaying buried ice. We evaluate this theory by employing a thermophysical model that considers insolation, scattering, thermal emissions and subsurface conduction. We model the area fraction of surface and subsurface cold-traps on realistic topography at scales of ˜500 m , recorded by the Mercury Laster Altimeter (MLA) on board the MErcury Surface, Space ENviroment, GEochemistry and Ranging (MESSENGER) spacecraft. At smaller scales, below the instrument threshold, we consider a statistical description of the surface assuming a Gaussian slope distribution. Using the modeled cold-trap area fraction we calculate the expected surface albedo and compare it to MESSENGER's near-infrared surface reflectance data. Last, we apply our model to other airless small-obliquity planetary bodies such as the Moon and Ceres in order to explain other correlations between the maximum temperature and normal albedo.
LOFT L2-3 blowdown experiment safety analyses D, E, and G; LOCA analyses H, K, K1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perryman, J.L.; Keeler, C.D.; Saukkoriipi, L.O.
1978-12-01
Three calculations using conservative off-nominal conditions and evaluation model options were made using RELAP4/MOD5 for blowdown-refill and RELAP4/MOD6 for reflood for Loss-of-Fluid Test Experiment L2-3 to support the experiment safety analysis effort. The three analyses are as follows: Analysis D: Loss of commercial power during Experiment L2-3; Analysis E: Hot leg quick-opening blowdown valve (QOBV) does not open during Experiment L2-3; and Analysis G: Cold leg QOBV does not open during Experiment L2-3. In addition, the results of three LOFT loss-of-coolant accident (LOCA) analyses using a power of 56.1 MW and a primary coolant system flow rate of 3.6 millionmore » 1bm/hr are presented: Analysis H: Intact loop 200% hot leg break; emergency core cooling (ECC) system B unavailable; Analysis K: Pressurizer relief valve stuck in open position; ECC system B unavailable; and Analysis K1: Same as analysis K, but using a primary coolant system flow rate of 1.92 million 1bm/hr (L2-4 pre-LOCE flow rate). For analysis D, the maximum cladding temperature reached was 1762/sup 0/F, 22 sec into reflood. In analyses E and G, the blowdowns were slower due to one of the QOBVs not functioning. The maximum cladding temperature reached in analysis E was 1700/sup 0/F, 64.7 sec into reflood; for analysis G, it was 1300/sup 0/F at the start of reflood. For analysis H, the maximum cladding temperature reached was 1825/sup 0/F, 0.01 sec into reflood. Analysis K was a very slow blowdown, and the cladding temperatures followed the saturation temperature of the system. The results of analysis K1 was nearly identical to analysis K; system depressurization was not affected by the primary coolant system flow rate.« less
Hapstack, Mark
1991-01-01
A pipe crawler having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radially outward to increase the range of the legs when the pipe crawler enters a section of a pipe having a larger diameter. The crawler crawls by "inchworm"-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly and bring up the rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward.
Hapstack, M.
1991-05-28
A pipe crawler is described having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radially outward to increase the range of the legs when the pipe crawler enters a section of a pipe having a larger diameter. The crawler crawls by inchworm'-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly and bring up the rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward. 5 figures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hapstack, M.
1991-05-28
A pipe crawler is described having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radially outward to increase the range of the legs when the pipe crawler enters a section of a pipe having a larger diameter. The crawler crawls by inchworm'-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly andmore » bring up the rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward. 5 figures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hapstack, M.
1990-05-01
A pipe crawler having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radically outward to increase the range of the legs when the pipe crawler enters a section of pipe having a larger diameter. The crawler crawls by inchworm''-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly and bring up themore » rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward. 5 figs.« less
Experiment data report for Semiscale Mod-1 Test S-05-1 (alternate ECC injection test)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feldman, E. M.; Patton, Jr., M. L.; Sackett, K. E.
Recorded test data are presented for Test S-05-1 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-1 was conducted from initial conditions of 2263 psia and 544/sup 0/F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the vessel lower plenum to simulatemore » emergency core coolant injection in a PWR, with the flow rate based on system volume scaling.« less
Posttest REALP4 analysis of LOFT experiment L1-3A
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, J.R.; Holmstrom, H.L.O.
This report presents selected results of posttest RELAP4 modeling of LOFT loss-of-coolant experiment L1-3A, a double-ended isothermal cold leg break with lower plenum emergency core coolant injection. Comparisons are presented between the pretest prediction, the posttest analysis, and the experimental data. It is concluded that pressurizer modeling is important for accurately predicting system behavior during the initial portion of saturated blowdown. Using measured initial conditions rather than nominal specified initial conditions did not influence the system model results significantly. Using finer nodalization in the reactor vessel improved the prediction of the system pressure history by minimizing steam condensation effects. Unequalmore » steam condensation between the downcomer and core volumes appear to cause the manometer oscillations observed in both the pretest and posttest RELAP4 analysis.« less
Study on iron disilicide thermoelectric generator
NASA Astrophysics Data System (ADS)
Anderson, Gerald
1987-11-01
The first objective of the experimental work is to verify the characteristics of commercially available material. The Japanese company Komatsu Electronics Ltd., sells U-Shaped couples of FeSi2. Twenty-four couples are now in our laboratory. Each leg of the couple is made of one type (N or P) of material and the junction is placed directly into a flame. Being almost impossible to measure the hot junction temperature in the flame and to evaluate the heat flux going through the material between hot and cold junctions, we have designed an experimental assembly, suited to measure these values. The main problem is to obtain a good thermal contact for the hot junctions. If not, there is an important temperature drop between the hot source and the hot junction of the couple leading to wrong values of the characteristics.
Active and Inactive Leg Hemodynamics during Sequential Single-Leg Interval Cycling.
Gordon, Nicole; Abbiss, Chris R; Ihsan, Mohammed; Maiorana, Andrew J; Peiffer, Jeremiah J
2018-06-01
Leg order during sequential single-leg cycling (i.e., exercising both legs independently within a single session) may affect local muscular responses potentially influencing adaptations. This study examined the cardiovascular and skeletal muscle hemodynamic responses during double-leg and sequential single-leg cycling. Ten young healthy adults (28 ± 6 yr) completed six 1-min double-leg intervals interspersed with 1 min of passive recovery and, on a separate occasion, 12 (six with one leg followed by six with the other leg) 1-min single-leg intervals interspersed with 1 min of passive recovery. Oxygen consumption, heart rate, blood pressure, muscle oxygenation, muscle blood volume, and power output were measured throughout each session. Oxygen consumption, heart rate, and power output were not different between sets of single-leg intervals, but the average of both sets was lower than the double-leg intervals. Mean arterial pressure was higher during double-leg compared with sequential single-leg intervals (115 ± 9 vs 104 ± 9 mm Hg, P < 0.05) and higher during the initial compared with second set of single-leg intervals (108 ± 10 vs 101 ± 10 mm Hg, P < 0.05). The increase in muscle blood volume from baseline was similar between the active single leg and the double leg (267 ± 150 vs 214 ± 169 μM·cm, P = 0.26). The pattern of change in muscle blood volume from the initial to second set of intervals was significantly different (P < 0.05) when the leg was active in the initial (-52.3% ± 111.6%) compared with second set (65.1% ± 152.9%). These data indicate that the order in which each leg performs sequential single-leg cycling influences the local hemodynamic responses, with the inactive muscle influencing the stimulus experienced by the contralateral leg.
Quadrupedal gaits in hexapod animals - inter-leg coordination in free-walking adult stick insects.
Grabowska, Martyna; Godlewska, Elzbieta; Schmidt, Joachim; Daun-Gruhn, Silvia
2012-12-15
The analysis of inter-leg coordination in insect walking is generally a study of six-legged locomotion. For decades, the stick insect Carausius morosus has been instrumental for unravelling the rules and mechanisms that control leg coordination in hexapeds. We analysed inter-leg coordination in C. morosus that freely walked on straight paths on plane surfaces with different slopes. Consecutive 1.7 s sections were assigned inter-leg coordination patterns (which we call gaits) based on footfall patterns. Regular gaits, i.e. wave, tetrapod or tripod gaits, occurred in different proportions depending on surface slopes. Tetrapod gaits were observed most frequently, wave gaits only occurred on 90 deg inclining slopes and tripod gaits occurred most often on 15 deg declining slopes, i.e. in 40% of the sections. Depending on the slope, 36-66% of the sections were assigned irregular gaits. Irregular gaits were mostly due to multiple stepping by the front legs, which is perhaps probing behaviour, not phase coupled to the middle legs' cycles. In irregular gaits, middle leg and hindleg coordination was regular, related to quadrupedal walk and wave gaits. Apparently, front legs uncouple from and couple to the walking system without compromising middle leg and hindleg coordination. In front leg amputees, the remaining legs were strictly coordinated. In hindleg and middle leg amputees, the front legs continued multiple stepping. The coordination of middle leg amputees was maladapted, with front legs and hindlegs performing multiple steps or ipsilateral legs being in simultaneous swing. Thus, afferent information from middle legs might be necessary for a regular hindleg stepping pattern.
Skipping on uneven ground: trailing leg adjustments simplify control and enhance robustness.
Müller, Roy; Andrada, Emanuel
2018-01-01
It is known that humans intentionally choose skipping in special situations, e.g. when descending stairs or when moving in environments with lower gravity than on Earth. Although those situations involve uneven locomotion, the dynamics of human skipping on uneven ground have not yet been addressed. To find the reasons that may motivate this gait, we combined experimental data on humans with numerical simulations on a bipedal spring-loaded inverted pendulum model (BSLIP). To drive the model, the following parameters were estimated from nine subjects skipping across a single drop in ground level: leg lengths at touchdown, leg stiffness of both legs, aperture angle between legs, trailing leg angle at touchdown (leg landing first after flight phase), and trailing leg retraction speed. We found that leg adjustments in humans occur mostly in the trailing leg (low to moderate leg retraction during swing phase, reduced trailing leg stiffness, and flatter trailing leg angle at lowered touchdown). When transferring these leg adjustments to the BSLIP model, the capacity of the model to cope with sudden-drop perturbations increased.
Thermal sensation during mild hyperthermia is modulated by acute postural change in humans
NASA Astrophysics Data System (ADS)
Takeda, Ryosuke; Imai, Daiki; Suzuki, Akina; Ota, Akemi; Naghavi, Nooshin; Yamashina, Yoshihiro; Hirasawa, Yoshikazu; Yokoyama, Hisayo; Miyagawa, Toshiaki; Okazaki, Kazunobu
2016-12-01
Thermal sensation represents the primary stimulus for behavioral and autonomic thermoregulation. We assessed whether the sensation of skin and core temperatures for the driving force of behavioral thermoregulation was modified by postural change from the supine (Sup) to sitting (Sit) during mild hyperthermia. Seventeen healthy young men underwent measurements of noticeable increase and decrease (±0.1 °C/s) of skin temperature (thresholds of warm and cold sensation on the skin, 6.25 cm2 of area) at the forearm and chest and of the whole-body warm sensation in the Sup and Sit during normothermia (NT; esophageal temperature (Tes), ˜36.6 °C) and mild hyperthermia (HT; Tes, ˜37.2 °C; lower legs immersion in 42 °C of water). The threshold for cold sensation on the skin at chest was lower during HT than NT in the Sit ( P < 0.05) but not in Sup, and at the forearm was lower during HT than NT in the Sup and further in Sit (both, P < 0.05), with interactive effects of temperature (NT vs. HT) × posture (Sup vs. Sit) (chest, P = 0.08; forearm, P < 0.05). The threshold for warm sensation on the skin at both sites remained unchanged with changes in body posture or temperature. The whole-body warm sensation was higher during HT than NT in both postures and higher in the Sit than Sup during both NT and HT (all, P < 0.05). Thus, thermal sensation during mild hyperthermia is modulated by postural change from supine to sitting to sense lesser cold on the skin and more whole-body warmth.
Thermal sensation during mild hyperthermia is modulated by acute postural change in humans.
Takeda, Ryosuke; Imai, Daiki; Suzuki, Akina; Ota, Akemi; Naghavi, Nooshin; Yamashina, Yoshihiro; Hirasawa, Yoshikazu; Yokoyama, Hisayo; Miyagawa, Toshiaki; Okazaki, Kazunobu
2016-12-01
Thermal sensation represents the primary stimulus for behavioral and autonomic thermoregulation. We assessed whether the sensation of skin and core temperatures for the driving force of behavioral thermoregulation was modified by postural change from the supine (Sup) to sitting (Sit) during mild hyperthermia. Seventeen healthy young men underwent measurements of noticeable increase and decrease (±0.1 °C/s) of skin temperature (thresholds of warm and cold sensation on the skin, 6.25 cm 2 of area) at the forearm and chest and of the whole-body warm sensation in the Sup and Sit during normothermia (NT; esophageal temperature (T es ), ∼36.6 °C) and mild hyperthermia (HT; T es , ∼37.2 °C; lower legs immersion in 42 °C of water). The threshold for cold sensation on the skin at chest was lower during HT than NT in the Sit (P < 0.05) but not in Sup, and at the forearm was lower during HT than NT in the Sup and further in Sit (both, P < 0.05), with interactive effects of temperature (NT vs. HT) × posture (Sup vs. Sit) (chest, P = 0.08; forearm, P < 0.05). The threshold for warm sensation on the skin at both sites remained unchanged with changes in body posture or temperature. The whole-body warm sensation was higher during HT than NT in both postures and higher in the Sit than Sup during both NT and HT (all, P < 0.05). Thus, thermal sensation during mild hyperthermia is modulated by postural change from supine to sitting to sense lesser cold on the skin and more whole-body warmth.
Eisensehr, Ilonka
2007-10-18
Paraesthesia in the legs can have numerous causes. In addition to the restless legs syndrome, other primary causes include venous insufficiency in the leg, propriospinal myoclonus, nocturnal leg cramps, peripheral polyneuropathy that affects mostly the legs or neuroleptic drug-induced akathisia. Through detailed questioning of the patient, restless legs syndrome can be specifically distinguished from the other named differential diagnoses.
Toney, Megan E.; Chang, Young-Hui
2016-01-01
Human walking is a complex task, and we lack a complete understanding of how the neuromuscular system organizes its numerous muscles and joints to achieve consistent and efficient walking mechanics. Focused control of select influential task-level variables may simplify the higher-level control of steady state walking and reduce demand on the neuromuscular system. As trailing leg power generation and force application can affect the mechanical efficiency of step-to-step transitions, we investigated how joint torques are organized to control leg force and leg power during human walking. We tested whether timing of trailing leg force control corresponded with timing of peak leg power generation. We also applied a modified uncontrolled manifold analysis to test whether individual or coordinated joint torque strategies most contributed to leg force control. We found that leg force magnitude was adjusted from step-to-step to maintain consistent leg power generation. Leg force modulation was primarily determined by adjustments in the timing of peak ankle plantar-flexion torque, while knee torque was simultaneously covaried to dampen the effect of ankle torque on leg force. We propose a coordinated joint torque control strategy in which the trailing leg ankle acts as a motor to drive leg power production while trailing leg knee torque acts as a brake to refine leg power production. PMID:27334888
Leg deformation during imaginal ecdysis in the downy emerald, Cordulia aenea (Odonata, Corduliidae).
Frantsevich, Leonid; Frantsevich, Ludmilla
2018-04-01
A dragonfly larva migrates from the water to the shore, perches on a plant stem and grasps it with strongly flexed legs. Adult legs inside the larval exoskeleton fit to the larval legs joint-to-joint. The adult emerges with stretched legs. During the molt, an imaginal leg must follow all the angles in exuvial joints. In turn, larval apodemes are withdrawn from imaginal legs. We visualized transient shapes of the imaginal legs by the instant fixation of insects at different moments of the molt, photographed isolated exuvial legs with the imaginal legs inside and then removed the exuvial sheath. Instant shapes of the imaginal tibia show sharp intrapodomere bends copying the angle in the larval femoro-tibial joint. The site of bending shifts distad during the molt. This is possible if the imaginal leg is pliable. The same problem of leg squeezing is also common in hemimetabolous insects as well as in other arthropods, whereas holometabolous insects overcome problems of a tight confinement either by using leg pliability in other ways but not squeezing (cyclorrhaphan flies, mosquitoes) or by pulling hardened legs out without change of their pupal zigzag configuration (moths, ants, honey bees). The pupal legs are not intended to grasp any external substrate. Copyright © 2018 Elsevier GmbH. All rights reserved.
Roberts, Llion A; Raastad, Truls; Markworth, James F; Figueiredo, Vandre C; Egner, Ingrid M; Shield, Anthony; Cameron-Smith, David; Coombes, Jeff S; Peake, Jonathan M
2015-01-01
Abstract We investigated functional, morphological and molecular adaptations to strength training exercise and cold water immersion (CWI) through two separate studies. In one study, 21 physically active men strength trained for 12 weeks (2 days per week), with either 10 min of CWI or active recovery (ACT) after each training session. Strength and muscle mass increased more in the ACT group than in the CWI group (P < 0.05). Isokinetic work (19%), type II muscle fibre cross-sectional area (17%) and the number of myonuclei per fibre (26%) increased in the ACT group (all P < 0.05), but not the CWI group. In another study, nine active men performed a bout of single-leg strength exercises on separate days, followed by CWI or ACT. Muscle biopsies were collected before and 2, 24 and 48 h after exercise. The number of satellite cells expressing neural cell adhesion molecule (NCAM) (10−30%) and paired box protein (Pax7) (20−50%) increased 24–48 h after exercise with ACT. The number of NCAM+ satellite cells increased 48 h after exercise with CWI. NCAM+- and Pax7+-positive satellite cell numbers were greater after ACT than after CWI (P < 0.05). Phosphorylation of p70S6 kinaseThr421/Ser424 increased after exercise in both conditions but was greater after ACT (P < 0.05). These data suggest that CWI attenuates the acute changes in satellite cell numbers and activity of kinases that regulate muscle hypertrophy, which may translate to smaller long-term training gains in muscle strength and hypertrophy. The use of CWI as a regular post-exercise recovery strategy should be reconsidered. Key points Cold water immersion is a popular strategy to recover from exercise. However, whether regular cold water immersion influences muscle adaptations to strength training is not well understood. We compared the effects of cold water immersion and active recovery on changes in muscle mass and strength after 12 weeks of strength training. We also examined the effects of these two treatments on hypertrophy signalling pathways and satellite cell activity in skeletal muscle after acute strength exercise. Cold water immersion attenuated long term gains in muscle mass and strength. It also blunted the activation of key proteins and satellite cells in skeletal muscle up to 2 days after strength exercise. Individuals who use strength training to improve athletic performance, recover from injury or maintain their health should therefore reconsider whether to use cold water immersion as an adjuvant to their training. PMID:26174323
Crystal structure of the complete integrin αVβ3 ectodomain plus an α/β transmembrane fragment
Xiong, Jian-Ping; Mahalingham, Bhuvaneshwari; Alonso, Jose Luis; Borrelli, Laura Ann; Rui, Xianliang; Anand, Saurabh; Hyman, Bradley T.; Rysiok, Thomas; Müller-Pompalla, Dirk; Goodman, Simon L.
2009-01-01
We determined the crystal structure of 1TM-αVβ3, which represents the complete unconstrained ectodomain plus short C-terminal transmembrane stretches of the αV and β3 subunits. 1TM-αVβ3 is more compact and less active in solution when compared with ΔTM-αVβ3, which lacks the short C-terminal stretches. The structure reveals a bent conformation and defines the α–β interface between IE2 (EGF-like 2) and the thigh domains. Modifying this interface by site-directed mutagenesis leads to robust integrin activation. Fluorescent lifetime imaging microscopy of inactive full-length αVβ3 on live cells yields a donor–membrane acceptor distance, which is consistent with the bent conformation and does not change in the activated integrin. These data are the first direct demonstration of conformational coupling of the integrin leg and head domains, identify the IE2–thigh interface as a critical steric barrier in integrin activation, and suggest that inside-out activation in intact cells may involve conformational changes other than the postulated switch to a genu-linear state. PMID:19704023
Energy absorption of impacts during running at various stride lengths.
Derrick, T R; Hamill, J; Caldwell, G E
1998-01-01
The foot-ground impact experienced during running produces a shock wave that is transmitted through the human skeletal system. This shock wave is attenuated by deformation of the ground/shoe as well as deformation of biological tissues in the body. The goal of this study was to investigate the locus of energy absorption during the impact phase of the running cycle. Running speed (3.83 m x s[-1]) was kept constant across five stride length conditions: preferred stride length (PSL), +10% of PSL, -10% of PSL, +20% of PSL, and -20% of PSL. Transfer functions were generated from accelerometers attached to the leg and head of ten male runners. A rigid body model was used to estimate the net energy absorbed at the hip, knee, and ankle joints. There was an increasing degree of shock attenuation as stride length increased. The energy absorbed during the impact portion of the running cycle also increased with stride length. Muscles that cross the knee joint showed the greatest adjustment in response to increased shock. It was postulated that the increased perpendicular distance from the line of action of the resultant ground reaction force to the knee joint center played a role in this increased energy absorption.
Yamazaki, J; Muneta, T; Ju, Y J; Sekiya, I
2010-01-01
Seventy to eighty percent of all anterior cruciate ligament (ACL) injuries are due to non-contact injury mechanisms. It has been reported that the majority of injuries due to single leg landing come from valgus positioning of the lower leg. Preventing valgus positioning during single leg landing is expected to help reduce the number of ACL injuries. We found that many ACL-deficient patients cannot perform stable single leg squatting. Therefore, we performed 3D motion analysis of the single-legged half squat for ACL-injured patients to evaluate its significance as a risk factor for ACL injuries. We evaluated the relative angles between the body, thigh, and lower leg using an electromagnetic device during single leg half squatting performed by 63 ACL-injured patients (32 males, 31 females) the day before ACL reconstruction and by 26 healthy control subjects with no knee problems. The uninjured leg of ACL-injured male subjects demonstrated significantly less external knee rotation than that of the dominant leg of the male control. The uninjured leg of ACL-injured female subjects demonstrated significantly more external hip rotation and knee flexion and less hip flexion than that of the dominant leg of the female control. Comparing injured and uninjured legs, the injured leg of male subjects demonstrated significantly less external knee and hip rotation, less knee flexion, and more knee varus than that of the uninjured leg of male subjects. The injured leg of female subjects demonstrated more knee varus than that of the uninjured leg of female subjects. Regarding gender differences, female subjects demonstrated significantly more external hip rotation and knee valgus than male subjects did in both the injured and uninjured legs (P < 0.05). The current kinematic study exhibited biomechanical characteristics of female ACL-injured subjects compared with that of control groups. Kinematic correction during single leg half squat would reduce ACL reinjury in female ACL-injured subjects.
Behaviour of F82H mod. stainless steel in lead-bismuth under temperature gradient
NASA Astrophysics Data System (ADS)
Gómez Briceño, D.; Martín Muñoz, F. J.; Soler Crespo, L.; Esteban, F.; Torres, C.
2001-07-01
Austenitic steels can be used in a hybrid system in contact with liquid lead-bismuth eutectic if the region of operating temperatures is not beyond 400°C. For higher temperatures, martensitic steels are recommended. However, at long times, the interaction between the structural material and the eutectic leads to the dissolution of some elements of the steel (Ni, Cr and Fe, mainly) in the liquid metal. In a non-isothermal lead-bismuth loop, the material dissolution takes place at the hot leg of the circuit and, due to the mass transfer, deposition occurs at the cold leg. One of the possible ways to improve the performance of structural materials in lead-bismuth is the creation of an oxide layer. Tests have been performed in a small natural convection loop built of austenitic steel (316L) that has been operating for 3000 h. This loop contains a test area in which several samples of F82Hmod. martensitic steel have been tested at different times. A gas with an oxygen content of 10 ppm was bubbled in the hot area of the circuit during the operation time. The obtained results show that an oxide layer is formed on the samples introduced in the loop at the beginning of the operation and this layer increases with time. However, the samples introduced at different times during the loop operation, are not protected by oxide layers and present material dissolution in some cases.
Varona, L; Moreno, C; Altarriba, J
2012-06-01
Survival or longevity is an economically relevant trait in cattle. However, it is not currently included in cattle selection criteria because of the delayed recording of phenotypic data and the high computational demand of survival techniques under proportional hazard models. The identification of longevity-correlated traits that can be early registered in lifetime would therefore be very useful for beef cattle selection processes. The aim of this study was to estimate the genetic correlation of survival (SURV) with: growth - birth weight (BW), weight at 120 days (W120), weight at 210 days (W210); carcass - cold carcass weight (CCW), conformation (CON), fatness (FAT) and meat colour (COL); teat morphology - teat thickness (TT), teat length (TL) and udder depth (UD); leg morphology - forward (FL) and backward legs (BL); milk production (MILK) and docility (DOC). In the statistical analysis, SURV was measured in discrete-time intervals and modelled via a sequential threshold model. A series of independent bivariate Bayesian analyses between cow survival and each recorded trait were carried out. The posterior mean estimates (and posterior standard deviation) for the heritability of SURV was 0.05 (0.01); and for the relevant genetic correlations with SURV were 0.07 (0.04), 0.12 (0.05), 0.10 (0.05), 0.15 (0.05), -0.18 (0.06), 0.33 (0.06) and 0.27 (0.15) for BW, W120, W210, CCW, CON, FAT and COL, respectively.
CAT scan - leg; Computed axial tomography scan - leg; Computed tomography scan - leg; CT scan - leg ... CT scan makes detailed pictures of the body very quickly. The test may help look for: An abscess ...
Knutson, Gary A
2005-01-01
Background Part II of this review examines the functional "short leg" or unloaded leg length alignment asymmetry, including the relationship between an anatomic and functional leg-length inequality. Based on the reviewed evidence, an outline for clinical decision making regarding functional and anatomic leg-length inequality will be provided. Methods Online databases: Medline, CINAHL and Mantis. Plus library searches for the time frame of 1970–2005 were done using the term "leg-length inequality". Results and Discussion The evidence suggests that an unloaded leg-length asymmetry is a different phenomenon than an anatomic leg-length inequality, and may be due to suprapelvic muscle hypertonicity. Anatomic leg-length inequality and unloaded functional or leg-length alignment asymmetry may interact in a loaded (standing) posture, but not in an unloaded (prone/supine) posture. Conclusion The unloaded, functional leg-length alignment asymmetry is a likely phenomenon, although more research regarding reliability of the measurement procedure and validity relative to spinal dysfunction is needed. Functional leg-length alignment asymmetry should be eliminated before any necessary treatment of anatomic LLI. PMID:16080787
A colored leg banding technique for Amazona parrots
Meyers, J.M.
1995-01-01
A technique for individual identification of Amazona was developed using plastic leg bands. Bands were made from 5- and 7-mm-wide strips of laminated PVC coiled 2.5 times with an inside diameter 4-5 mm gt the maximum diameter of the parrot's leg. Seventeen parrots were captured in Puerto Rico, marked with individual plastic leg bands, and observed for 204-658 d with only one lost or damaged plastic band. Plastic leg bands did not cause injury to or calluses on parrots' legs. The plastic material used for making leg bands was available in 18 colors in 1994, which would allow unique marking of 306 individuals using one plastic leg band on each leg.
NASA Astrophysics Data System (ADS)
Scholtz, Gerhard; Brenneis, Georg
2016-02-01
A malformed adult female specimen of Pycnogonum litorale (Pycnogonida) with a supernumerary leg in the right body half is described concerning external and internal structures. The specimen was maintained in our laboratory culture after an injury in the right trunk region during a late postembryonic stage. The supernumerary leg is located between the second and third walking legs. The lateral processes connecting to these walking legs are fused to one large structure. Likewise, the coxae 1 of the second and third walking legs and of the supernumerary leg are fused to different degrees. The supernumerary leg is a complete walking leg with mirror image symmetry as evidenced by the position of joints and muscles. It is slightly smaller than the normal legs, but internally, it contains a branch of the ovary and a gut diverticulum as the other legs. The causes for this malformation pattern found in the Pycnogonum individual are reconstructed in the light of extirpation experiments in insects, which led to supernumerary mirror image legs, and the "boundary model" for appendage differentiation.
Human and avian running on uneven ground: a model-based comparison
Birn-Jeffery, A. V.; Blum, Y.
2016-01-01
Birds and humans are successful bipedal runners, who have individually evolved bipedalism, but the extent of the similarities and differences of their bipedal locomotion is unknown. In turn, the anatomical differences of their locomotor systems complicate direct comparisons. However, a simplifying mechanical model, such as the conservative spring–mass model, can be used to describe both avian and human running and thus, provides a way to compare the locomotor strategies that birds and humans use when running on level and uneven ground. Although humans run with significantly steeper leg angles at touchdown and stiffer legs when compared with cursorial ground birds, swing-leg adaptations (leg angle and leg length kinematics) used by birds and humans while running appear similar across all types of uneven ground. Nevertheless, owing to morphological restrictions, the crouched avian leg has a greater range of leg angle and leg length adaptations when coping with drops and downward steps than the straight human leg. On the other hand, the straight human leg seems to use leg stiffness adaptation when coping with obstacles and upward steps unlike the crouched avian leg posture. PMID:27655670
Intramuscular pressures beneath elastic and inelastic leggings
NASA Technical Reports Server (NTRS)
Murthy, G.; Ballard, R. E.; Breit, G. A.; Watenpaugh, D. E.; Hargens, A. R.
1994-01-01
Leg compression devices have been used extensively by patients to combat chronic venous insufficiency and by astronauts to counteract orthostatic intolerance following spaceflight. However, the effects of elastic and inelastic leggings on the calf muscle pump have not been compared. The purpose of this study was to compare in normal subjects the effects of elastic and inelastic compression on leg intramuscular pressure (IMP), an objective index of calf muscle pump function. IMP in soleus and tibialis anterior muscles was measured with transducer-tipped catheters. Surface compression between each legging and the skin was recorded with an air bladder. Subjects were studied under three conditions: (1) control (no legging), (2) elastic legging, and (3) inelastic legging. Pressure data were recorded for each condition during recumbency, sitting, standing, walking, and running. Elastic leggings applied significantly greater surface compression during recumbency (20 +/- 1 mm Hg, mean +/- SE) than inelastic leggings (13 +/- 2 mm Hg). During recumbency, elastic leggings produced significantly higher soleus IMP of 25 +/- 1 mm Hg and tibialis anterior IMP of 28 +/- 1 mm Hg compared to 17 +/- 1 mm Hg and 20 +/- 2 mm Hg, respectively, generated by inelastic leggings and 8 +/- 1 mm Hg and 11 +/- 1 mm Hg, respectively, without leggings. During sitting, walking, and running, however, peak IMPs generated in the muscular compartments by elastic and inelastic leggings were similar. Our results suggest that elastic leg compression applied over a long period in the recumbent posture may impede microcirculation and jeopardize tissue viability.(ABSTRACT TRUNCATED AT 250 WORDS).
Perry, Ben D; Wyckelsma, Victoria L; Murphy, Robyn M; Steward, Collene H; Anderson, Mitchell; Levinger, Itamar; Petersen, Aaron C; McKenna, Michael J
2016-11-01
Physical training increases skeletal muscle Na + ,K + -ATPase content (NKA) and improves exercise performance, but the effects of inactivity per se on NKA content and isoform abundance in human muscle are unknown. We investigated the effects of 23-day unilateral lower limb suspension (ULLS) and subsequent 4-wk resistance training (RT) on muscle function and NKA in 6 healthy adults, measuring quadriceps muscle peak torque; fatigue and venous [K + ] during intense one-legged cycling exercise; and skeletal muscle NKA content ([ 3 H]ouabain binding) and NKA isoform abundances (immunoblotting) in muscle homogenates (α 1-3 , β 1-2 ) and in single fibers (α 1-3 , β 1 ). In the unloaded leg after ULLS, quadriceps peak torque and cycling time to fatigue declined by 22 and 23%, respectively, which were restored with RT. Whole muscle NKA content and homogenate NKA α 1-3 and β 1-2 isoform abundances were unchanged with ULLS or RT. However, in single muscle fibers, NKA α 3 in type I (-66%, P = 0.006) and β 1 in type II fibers (-40%, P = 0.016) decreased after ULLS, with other NKA isoforms unchanged. After RT, NKA α 1 (79%, P = 0.004) and β 1 (35%, P = 0.01) increased in type II fibers, while α 2 (76%, P = 0.028) and α 3 (142%, P = 0.004) increased in type I fibers compared with post-ULLS. Despite considerably impaired muscle function and earlier fatigue onset, muscle NKA content and homogenate α 1 and α 2 abundances were unchanged, thus being resilient to inactivity induced by ULLS. Nonetheless, fiber type-specific downregulation with inactivity and upregulation with RT of several NKA isoforms indicate complex regulation of muscle NKA expression in humans. Copyright © 2016 the American Physiological Society.
On the Biomimetic Design of Agile-Robot Legs
Garcia, Elena; Arevalo, Juan Carlos; Muñoz, Gustavo; Gonzalez-de-Santos, Pablo
2011-01-01
The development of functional legged robots has encountered its limits in human-made actuation technology. This paper describes research on the biomimetic design of legs for agile quadrupeds. A biomimetic leg concept that extracts key principles from horse legs which are responsible for the agile and powerful locomotion of these animals is presented. The proposed biomimetic leg model defines the effective leg length, leg kinematics, limb mass distribution, actuator power, and elastic energy recovery as determinants of agile locomotion, and values for these five key elements are given. The transfer of the extracted principles to technological instantiations is analyzed in detail, considering the availability of current materials, structures and actuators. A real leg prototype has been developed following the biomimetic leg concept proposed. The actuation system is based on the hybrid use of series elasticity and magneto-rheological dampers which provides variable compliance for natural motion. From the experimental evaluation of this prototype, conclusions on the current technological barriers to achieve real functional legged robots to walk dynamically in agile locomotion are presented. PMID:22247667
On the biomimetic design of agile-robot legs.
Garcia, Elena; Arevalo, Juan Carlos; Muñoz, Gustavo; Gonzalez-de-Santos, Pablo
2011-01-01
The development of functional legged robots has encountered its limits in human-made actuation technology. This paper describes research on the biomimetic design of legs for agile quadrupeds. A biomimetic leg concept that extracts key principles from horse legs which are responsible for the agile and powerful locomotion of these animals is presented. The proposed biomimetic leg model defines the effective leg length, leg kinematics, limb mass distribution, actuator power, and elastic energy recovery as determinants of agile locomotion, and values for these five key elements are given. The transfer of the extracted principles to technological instantiations is analyzed in detail, considering the availability of current materials, structures and actuators. A real leg prototype has been developed following the biomimetic leg concept proposed. The actuation system is based on the hybrid use of series elasticity and magneto-rheological dampers which provides variable compliance for natural motion. From the experimental evaluation of this prototype, conclusions on the current technological barriers to achieve real functional legged robots to walk dynamically in agile locomotion are presented.
Cao, Feng; Zhang, Chao; Vo Doan, Tat Thang; Li, Yao; Sangi, Daniyal Haider; Koh, Jie Sheng; Huynh, Ngoc Anh; Bin Aziz, Mohamed Fareez; Choo, Hao Yu; Ikeda, Kazuo; Abbeel, Pieter; Maharbiz, Michel M; Sato, Hirotaka
2014-01-01
In this study, a biological microactuator was demonstrated by closed-loop motion control of the front leg of an insect (Mecynorrhina torquata, beetle) via electrical stimulation of the leg muscles. The three antagonistic pairs of muscle groups in the front leg enabled the actuator to have three degrees of freedom: protraction/retraction, levation/depression, and extension/flexion. We observed that the threshold amplitude (voltage) required to elicit leg motions was approximately 1.0 V; thus, we fixed the stimulation amplitude at 1.5 V to ensure a muscle response. The leg motions were finely graded by alternation of the stimulation frequencies: higher stimulation frequencies elicited larger leg angular displacement. A closed-loop control system was then developed, where the stimulation frequency was the manipulated variable for leg-muscle stimulation (output from the final control element to the leg muscle) and the angular displacement of the leg motion was the system response. This closed-loop control system, with an optimized proportional gain and update time, regulated the leg to set at predetermined angular positions. The average electrical stimulation power consumption per muscle group was 148 µW. These findings related to and demonstrations of the leg motion control offer promise for the future development of a reliable, low-power, biological legged machine (i.e., an insect-machine hybrid legged robot).
RELAP5 posttest calculation of IAEA-SPE-4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petelin, S.; Mavko, B.; Parzer, I.
The International Atomic Energy Agency`s Fourth Standard Problem Exercise (IAEA-SPE-4) was performed at the PMK-2 facility. The PMK-2 facility is designed to study processes following small- and medium-size breaks in the primary system and natural circulation in VVER-440 plants. The IAEA-SPE-4 experiment represents a cold-leg side small break, similar to the IAEA-SPE-2, with the exception of the high-pressure safety injection being unavailable, and the secondary side bleed and feed initiation. The break valve was located at the dead end of a vertical downcomer, which in fact simulates a break in the reactor vessel itself, and should be unlikely to happenmore » in a real nuclear power plant (NPP). Three different RELAP5 code versions were used for the transient simulation in order to assess the calculations with test results.« less
Parolari, Giovanni; Benedini, Riccardo; Toscani, Tania
2009-08-01
The development of red pigment Zn-protoporphyrin IX (ZPP) in nitrite-free Parma hams was investigated in 5 leg muscles at several stages of processing and the activity of muscle Zn-chelatase was concurrently assayed for its potential role in ZPP formation. A steady increase of the pigment was observed throughout the manufacturing stages at mild temperatures while no development was observed during the prior cold resting phase. The enzyme was partly inactivated according to a muscle-dependent pattern, resulting in similar ZPP contents, hence color, in finished hams. It is concluded that enzyme-dependent synthesis of ZPP in nitrite-free dried hams contributes to color development, enabling muscles in dried hams to become more similar in redness than in green thighs. Therefore, checking raw meat for the enzyme content may be a means to control color formation in nitrite-free dry-cured meat derivatives.
Variation in age at metamorphosis across a latitudinal gradient for the tailed frog, Ascaphus truei
Bury, R. Bruce; Adams, Michael J.
1999-01-01
Tailed frogs (Ascaphus truei) occur in permanent, cold streams in northwestern North America. Their tadpoles reportedly undergo metamorphosis after 2-4 years. Coastal populations that we examined transformed in 2 yr from the Olympic peninsula in Washington to northern Oregon, but in 1 yr from central Oregon to northern California. One inland site in northern California had a 2-yr period. Age at metamorphosis was consistent over different years. We suggest that total length and developmental stage accurately define cohorts for larval Ascaphus. Hind-leg length indicates whether metamorphs are a separate age class from tadpoles. Age at metamorphosis (1-4 yr) appears to reflect broad differences in climatic conditions. However, at a regional scale, variation is low and suggests a lack of sensitivity to local environmental conditions. This may be due to seasonal constraints on the time when metamorphosis occurs (late summer).
Fleet Assignment Using Collective Intelligence
NASA Technical Reports Server (NTRS)
Antoine, Nicolas E.; Bieniawski, Stefan R.; Kroo, Ilan M.; Wolpert, David H.
2004-01-01
Product distribution theory is a new collective intelligence-based framework for analyzing and controlling distributed systems. Its usefulness in distributed stochastic optimization is illustrated here through an airline fleet assignment problem. This problem involves the allocation of aircraft to a set of flights legs in order to meet passenger demand, while satisfying a variety of linear and non-linear constraints. Over the course of the day, the routing of each aircraft is determined in order to minimize the number of required flights for a given fleet. The associated flow continuity and aircraft count constraints have led researchers to focus on obtaining quasi-optimal solutions, especially at larger scales. In this paper, the authors propose the application of this new stochastic optimization algorithm to a non-linear objective cold start fleet assignment problem. Results show that the optimizer can successfully solve such highly-constrained problems (130 variables, 184 constraints).
Nuclear reactor vessel fuel thermal insulating barrier
Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.
2013-03-19
The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.
Shin splints: painful to have and to treat.
Story, Julie; Cymet, Tyler Childs
2006-01-01
When people overuse their legs they develop an uncomfortable awareness of these limbs manifested as a dull burning or aching. The cause is often clear to the person with the problem as a result of the often obvious relationship to overdoing an exercise or activity and the pain. "Shin splints" is the lay term; physicians use the term medial tibial stress syndrome. The pathophysiology that leads to this pain is unclear, although there are a number of competing theories. Differential diagnosis includes stress fractures and compartment syndromes. Bone tumors or lipomas can also cause similar pain to shin splints. Diagnosis can be made by history alone in a majority of cases, but if the diagnosis is unclear, an X-ray and magnetic resonance imaging should be considered. Treatment is still mostly supportive and symptom related. Rest is the most important aspect of treatment. Locally applied cold and anti-inflammatory medication have also been felt to be beneficial.
Current Sheet Structures Observed by the TESIS EUV Telescope during a Flux Rope Eruption on the Sun
NASA Astrophysics Data System (ADS)
Reva, A. A.; Ulyanov, A. S.; Kuzin, S. V.
2016-11-01
We use the TESIS EUV telescope to study the current sheet signatures observed during flux rope eruption. The special feature of the TESIS telescope was its ability to image the solar corona up to a distance of 2 {R}⊙ from the Sun’s center in the Fe 171 Å line. The Fe 171 Å line emission illuminates the magnetic field lines, and the TESIS images reveal the coronal magnetic structure at high altitudes. The analyzed coronal mass ejection (CME) had a core with a spiral—flux rope—structure. The spiral shape indicates that the flux rope radius varied along its length. The flux rope had a complex temperature structure: cold legs (70,000 K, observed in He 304 Å line) and a hotter core (0.7 MK, observed in Fe 171 Å line). Such a structure contradicts the common assumption that the CME core is a cold prominence. When the CME impulsively accelerated, a dark double Y-structure appeared below the flux rope. The Y-structure timing, location, and morphology agree with the previously performed MHD simulations of the current sheet. We interpreted the Y-structure as a hot envelope of the current sheet and hot reconnection outflows. The Y-structure had a thickness of 6.0 Mm. Its length increased over time from 79 Mm to more than 411 Mm.
Knee Biomechanics During Jogging After Arthroscopic Partial Meniscectomy: A Longitudinal Study.
Hall, Michelle; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Cicuttini, Flavia M; Dempsey, Alasdair R; Lloyd, David G; Bennell, Kim L
2017-07-01
Altered knee joint biomechanics is thought to play a role in the pathogenesis of knee osteoarthritis and has been reported in patients after arthroscopic partial meniscectomy (APM) while performing various activities. Longitudinally, understanding knee joint biomechanics during jogging may assist future studies to assess the implications of jogging on knee joint health in this population. To investigate knee joint biomechanics during jogging in patients 3 months after APM and a healthy control group at baseline and 2 years later at follow-up. Controlled laboratory study. Seventy-eight patients who underwent medial APM and 38 healthy controls underwent a 3-dimensional motion analysis during barefoot overground jogging at baseline. Sixty-four patients who underwent APM and 23 controls returned at follow-up. External peak moments (flexion and adduction) and the peak knee flexion angle during stance were evaluated for the APM leg, non-APM leg (nonoperated leg), and control leg. At baseline, the peak knee flexion angle was 1.4° lower in the APM leg compared with the non-APM leg ( P = .03). No differences were found between the moments in the APM leg compared with the control leg (all P > .05). However, the normalized peak knee adduction moment was 35% higher in the non-APM leg compared with the control leg ( P = .008). In the non-APM leg, the normalized peak knee adduction and flexion moments were higher compared with the APM leg by 16% and 10%, respectively, at baseline ( P ≤ .004). Despite the increase in the peak knee flexion moment in the APM leg compared with the non-APM leg ( P < .001), there were no differences in the peak knee flexion moment or any other parameter assessed at 2-year follow-up between the legs ( P > .05). Comparing the APM leg and control leg, no differences in knee joint biomechanics during jogging for the variables assessed were observed. Higher knee moments in the non-APM leg may have clinical implications for the noninvolved leg. Kinematic differences were small (~1.4°) and therefore of questionable clinical relevance. These results may facilitate future clinical research regarding the implications of jogging on knee joint health in middle-aged, overweight patients after APM.
Feng, Jing; Pierce, Rosemary; Do, K Patrick; Aiona, Michael
2014-01-01
Asymmetry between limbs in people with spastic hemiplegic cerebral palsy (HEMI) adversely affects limb coordination and energy generation and consumption. This study compared how the affected leg and the unaffected leg of children with HEMI would differ based on which leg trails. Full-body gait analysis data and force-plate data were analyzed for 31 children (11.9 ± 3.8 years) with HEMI and 23 children (11.1 ± 3.1 years) with typical development (TD). Results showed that peak posterior center of mass-center of pressure (COM-COP) inclination angles of HEMI were smaller than TD when the affected leg trailed but not when the unaffected leg trailed. HEMI showed greater peak medial COM-COP inclination angles and wider step width than TD, no matter which leg trailed. More importantly, when the affected leg of HEMI trailed, it did not perform enough positive work during double support to propel COM motion. Consequently, the unaffected leg had to perform additional positive work during the early portion of single support, which costs more energy. When the unaffected leg trailed, the affected leg performed more negative work during double support; therefore, more positive work was still needed during early single support, but energy efficiency was closer to that of TD. Energy recovery factor was lower when the affected leg trailed than when the unaffected leg trailed; both were lower than TD. These findings suggest that the trailing leg plays a significant role in propelling COM motion during double support, and the 'unaffected' side of HEMI may not be completely unaffected. It is important to strengthen both legs. Copyright © 2013 Elsevier B.V. All rights reserved.
Design of a Single Motor Based Leg Structure with the Consideration of Inherent Mechanical Stability
NASA Astrophysics Data System (ADS)
Taha Manzoor, Muhammad; Sohail, Umer; Noor-e-Mustafa; Nizami, Muhammad Hamza Asif; Ayaz, Yasar
2017-07-01
The fundamental aspect of designing a legged robot is constructing a leg design that is robust and presents a simple control problem. In this paper, we have successfully designed a robotic leg based on a unique four bar mechanism with only one motor per leg. The leg design parameters used in our platform are extracted from design principles used in biological systems, multiple iterations and previous research findings. These principles guide a robotic leg to have minimal mechanical passive impedance, low leg mass and inertia, a suitable foot trajectory utilizing a practical balance between leg kinematics and robot usage, and the resultant inherent mechanical stability. The designed platform also exhibits the key feature of self-locking. Theoretical tools and software iterations were used to derive these practical features and yield an intuitive sense of the required leg design parameters.
Santamaría, E; Cabrera, O L; Avendaño, J; Pardo, R H
2016-01-01
Phlebotomine sandflies lose their legs after exposure to pyrethroids. In some insects leg loss helps to defend them from intoxication and predation, a phenomenon known as autotomy. A field observation has shown that sandflies that have lost some legs are still able to blood-feed. The aims of the study were to determine whether leg loss in sandflies, after exposure to deltamethrin, is due to autotomy and to establish the effect of the leg loss on blood-feeding. Two experiments were carried out with Lutzomyia longipalpis: (i) Females were individually exposed to a sublethal time of deltamethrin and mortality and the number of leg loss were recorded; and (ii) Groups of females with complete legs or with 1-3 legs lost due to pyrethroid exposure were offered a blood meal and percentages of blood-fed and fully-fed females were recorded. Most females lost a median of 1 leg within 1-48 h post-exposure to deltamethrin. Mortality (after 24 h) was significantly higher for exposed females with lost legs (31.1%), compared to exposed females with complete legs (7.3%), and there were no differences in mortality between females with complete legs and the control (unexposed females). There were no differences between the three treatments in the percentages of blood-fed and fully-fed females. Leg loss in sandflies is a toxic effect of pyrethroids and there was no evidence of autotomy. The loss of up to three legs after exposure to pyrethroids does not affect blood-feeding behaviour in laboratory and probably also in wild conditions.
The effect of leg preference on postural stability in healthy athletes.
Huurnink, Arnold; Fransz, Duncan P; Kingma, Idsart; Hupperets, Maarten D W; van Dieën, Jaap H
2014-01-03
In research regarding postural stability, leg preference is often tested and controlled for. However, leg preference may vary between tasks. As athletes are a group of interest for postural stability testing, we evaluated the effect of five leg preference tasks categorization (step up, hop, ball kick, balance, pick up) on single-leg postural stability of 16 field hockey athletes. The 'center of pressure speed' was calculated as the primary outcome variable of single-leg postural stability. Secondary variables were 'mean length of the GRF vector in the horizontal plane', 'mean length of the ankle angular velocity vector', and 'mean length of the hip angular velocity vector', as well as the separate outcomes per degree of freedom. Results showed that leg preference was inconsistent between leg preference tasks. Moreover, the primary and secondary variables yielded no significant difference between the preferred and non-preferred legs, regardless of the applied leg preference task categorization (p>0.05). The present findings do not support the usability of leg preference tasks in controlling for bias of postural stability. In conclusion, none of the applied leg preference tasks revealed a significant effect on postural stability in healthy field hockey athletes. © 2013 Published by Elsevier Ltd.
The Lower Extremity Biomechanics of Single- and Double-Leg Stop-Jump Tasks
2011-01-01
The anterior cruciate ligament (ACL) injury is a common occurrence in sports requiring stop-jump tasks. Single- and double-leg stop-jump techniques are frequently executed in sports. The higher risk of ACL injury in single-leg drop landing task compared to a double-leg drop landing task has been identified. However the injury bias between single- and double-leg landing techniques has not been investigated for stop-jump tasks. The purpose of this study was to determine the differences between single- and double-leg stop-jump tasks in knee kinetics that were influenced by the lower extremity kinematics during the landing phase. Ground reaction force, lower extremity kinematics, and knee kinetics data during the landing phase were obtained from 10 subjects performing single- and double-leg stop-jump tasks, using motion-capture system and force palates. Greater peak posterior and vertical ground reaction forces, and peak proximal tibia anterior and lateral shear forces (p < 0.05) during landing phase were observed of single-leg stop-jump. Single-leg stop-jump exhibited smaller hip and knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground (p < 0.05). We found smaller peak hip and knee flexion angles (p < 0.05) during the landing phase of single-leg stop-jump. These results indicate that single-leg landing may have higher ACL injury risk than double-leg landing in stop-jump tasks that may be influenced by the lower extremity kinematics during the landing phase. Key points Non-contact ACL injuries are more likely to occur during the single-leg stop-jump task than during the double-leg stop-jump task. Single-leg stop-jump exhibited greater peak proximal tibia anterior and lateral shear forces, and peak posterior and vertical ground reaction forces during the landing phase than the double-leg stop-jump task. Single-leg stop-jump exhibited smaller hip flexion angle, knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground. Single-leg stop-jump exhibited greater peak knee extension and valgus moment during the landing phase than the double-leg stop-jump task. Single-leg stop-jump extended the hip joint at initial foot contact with the ground. PMID:24149308
Endogenous pro-thrombotic biomarkers from the arm and leg may not have the same value.
Lattimer, Christopher R; Kalodiki, Evi; Geroulakos, George; Hoppensteadt, Debra; Fareed, Jawed
2016-05-01
Assessments of endogenous pro-thrombotic biomarkers are performed invariably on arm blood. However, the commonest site for thrombosis is in the leg. A leg blood sample may reflect local pro-thrombotic processes more accurately than systemic arm blood. The aim was to determine whether pro-thrombotic biomarkers from standard venous arm samples differed significantly from leg samples. Concurrent blood samples were taken from an ankle/lower calf varicose vein and an ante-cubital vein in 24 patients awaiting laser treatment as well as age approximated and sex matched healthy controls without venous disease. The following assays were performed: thrombin-antithrombin (ng/ml), antithrombin (%) activity, microparticles (nM), fibrinogen (mg/dl), prothrombin fragment 1.2 (F1.2) (pM) and P-selectin (ng/ml). Expressed as median (inter-quartile range). Significant arm/leg differences were observed in thrombin-antithrombin, antithrombin, prothrombin fragment 1.2 and P-selectin. The legs of patients had significantly reduced antithrombin activity and P-selectin concentrations compared to their arms (leg: 101 (90-108) versus arm: 112 (99-126), P = 0.001 and leg: 42 (26-52) versus 45 (27-52), P = 0.044, respectively). Control leg samples had significantly increased thrombin-antithrombin and P-selectin compared to control arm samples (leg: 2.1 (0.9-3.2) versus arm: 0.8 (0.5-1.7), P = 0.015 and leg: 36 (24-50) versus arm: 30 (23-41), P = 0.007, respectively). However, the control legs had significantly reduced F1.2 (leg: 265 (230-333) versus arm: 299 (236-361), P = 0.028). No significant arm/leg differences were detected in the microparticle or fibrinogen levels. These findings indicate that venous arm blood is significantly different from venous leg blood in four out of six biomarkers studied. Recognition of local venous leg sampling as a site for investigation may unravel why the leg has a greater predisposition to thrombosis and lead the way towards an arm/leg differential test. © The Author(s) 2015.
Oudenhoven, Laura M; Boes, Judith M; Hak, Laura; Faber, Gert S; Houdijk, Han
2017-01-25
Running specific prostheses (RSP) are designed to replicate the spring-like behaviour of the human leg during running, by incorporating a real physical spring in the prosthesis. Leg stiffness is an important parameter in running as it is strongly related to step frequency and running economy. To be able to select a prosthesis that contributes to the required leg stiffness of the athlete, it needs to be known to what extent the behaviour of the prosthetic leg during running is dominated by the stiffness of the prosthesis or whether it can be regulated by adaptations of the residual joints. The aim of this study was to investigate whether and how athletes with an RSP could regulate leg stiffness during distance running at different step frequencies. Seven endurance runners with an unilateral transtibial amputation performed five running trials on a treadmill at a fixed speed, while different step frequencies were imposed (preferred step frequency (PSF) and -15%, -7.5%, +7.5% and +15% of PSF). Among others, step time, ground contact time, flight time, leg stiffness and joint kinetics were measured for both legs. In the intact leg, increasing step frequency was accompanied by a decrease in both contact and flight time, while in the prosthetic leg contact time remained constant and only flight time decreased. In accordance, leg stiffness increased in the intact leg, but not in the prosthetic leg. Although a substantial contribution of the residual leg to total leg stiffness was observed, this contribution did not change considerably with changing step frequency. Amputee athletes do not seem to be able to alter prosthetic leg stiffness to regulate step frequency during running. This invariant behaviour indicates that RSP stiffness has a large effect on total leg stiffness and therefore can have an important influence on running performance. Nevertheless, since prosthetic leg stiffness was considerably lower than stiffness of the RSP, compliance of the residual leg should not be ignored when selecting RSP stiffness. Copyright © 2016 Elsevier Ltd. All rights reserved.
Supermassive black hole formation by cold accretion shocks in the first galaxies
NASA Astrophysics Data System (ADS)
Inayoshi, Kohei; Omukai, Kazuyuki
2012-05-01
We propose a new scenario for supermassive star (SMS: >rsim 105 M⊙) formation in shocked regions of colliding cold accretion flows near the centres of the first galaxies. Recent numerical simulations indicate that assembly of a typical first galaxy with virial temperature Tvir≳104 K proceeds via cold and dense flows penetrating deep to the centre, where supersonic streams collide with each other to develop a hot (˜104 K) and dense (˜103 cm-3) shocked gas. The post-shock layer first cools by efficient Lyα emission and contracts isobarically until ≃8000 K. Whether the layer continues its isobaric contraction depends on the density at this moment: if the density is high enough to excite H2 rovibrational levels collisionally (>rsim 104 cm-3), enhanced H2 collisional dissociation suppresses the gas from cooling further. In this case, the layer fragments into massive (>rsim 105 M⊙) clouds, which collapse isothermally (˜8000 K) by Lyα cooling without subsequent fragmentation. As an outcome, SMSs are expected to form and eventually evolve into the seeds of supermassive black holes (SMBHs). By calculating the thermal evolution of the post-shock gas, we delimit the range of post-shock conditions for SMS formation, which can be expressed as T≳6000 K (nH/104 cm-3)-1 for ? and T>rsim 5000 -6000 K for nH≳104 cm-3, depending somewhat on the initial ionization degree. We found that metal enrichment does not affect the above condition for metallicity below ≃10-3 Z⊙ if metals are in the gas phase, while condensation of several per cent of metals into dust decreases this critical value of metallicity by an order of magnitude. Unlike the previously proposed scenario for SMS formation, which postulates extremely strong ultraviolet radiation to quench H2 cooling, our scenario here naturally explains SMBH seed formation in the assembly process of the first galaxies, even without such strong radiation.
Wang, Runxiao; Zhao, Wentao; Li, Shujun; Zhang, Shunqi
2016-01-01
Both the linear leg spring model and the two-segment leg model with constant spring stiffness have been broadly used as template models to investigate bouncing gaits for legged robots with compliant legs. In addition to these two models, the other stiffness leg spring models developed using inspiration from biological characteristic have the potential to improve high-speed running capacity of spring-legged robots. In this paper, we investigate the effects of "J"-curve spring stiffness inspired by biological materials on running speeds of segmented legs during high-speed locomotion. Mathematical formulation of the relationship between the virtual leg force and the virtual leg compression is established. When the SLIP model and the two-segment leg model with constant spring stiffness and with "J"-curve spring stiffness have the same dimensionless reference stiffness, the two-segment leg model with "J"-curve spring stiffness reveals that (1) both the largest tolerated range of running speeds and the tolerated maximum running speed are found and (2) at fast running speed from 25 to 40/92 m s -1 both the tolerated range of landing angle and the stability region are the largest. It is suggested that the two-segment leg model with "J"-curve spring stiffness is more advantageous for high-speed running compared with the SLIP model and with constant spring stiffness.
2016-01-01
Both the linear leg spring model and the two-segment leg model with constant spring stiffness have been broadly used as template models to investigate bouncing gaits for legged robots with compliant legs. In addition to these two models, the other stiffness leg spring models developed using inspiration from biological characteristic have the potential to improve high-speed running capacity of spring-legged robots. In this paper, we investigate the effects of “J”-curve spring stiffness inspired by biological materials on running speeds of segmented legs during high-speed locomotion. Mathematical formulation of the relationship between the virtual leg force and the virtual leg compression is established. When the SLIP model and the two-segment leg model with constant spring stiffness and with “J”-curve spring stiffness have the same dimensionless reference stiffness, the two-segment leg model with “J”-curve spring stiffness reveals that (1) both the largest tolerated range of running speeds and the tolerated maximum running speed are found and (2) at fast running speed from 25 to 40/92 m s−1 both the tolerated range of landing angle and the stability region are the largest. It is suggested that the two-segment leg model with “J”-curve spring stiffness is more advantageous for high-speed running compared with the SLIP model and with constant spring stiffness. PMID:28018127
1993-03-25
attachment-angle :accessor leg-attachment-angle) (linkO :initform (make-instance ’linkO) :accessor linkO) ( linki :initform (make-instance ’ linki ...accessor linki ) (link2 :initform (make-instance ’link2) :accessor link2) (link3 :initform (make-instance ’link3) :accessor link3) (motion-complete-flag...inboard-link ( linki leg)) (linkO leg)) (setf (inboard-link (link2 leg)) ( linki leg)) (setf (inboard-link (link3 leg)) (link2 leg)) (rotate-link (linkO
Erickson, Brandon J; Zaferiou, Antonia; Chalmers, Peter N; Ruby, Deana; Malloy, Phillip; Luchetti, Timothy J; Verma, Nikhil N; Romeo, Anthony A
2017-11-01
Ulnar collateral ligament reconstruction (UCLR) has become a common procedure among baseball players of all levels. There are several graft choices in performing UCLR, one of which is a hamstring (gracilis or semitendinosus) autograft. It is unclear whether the hamstring muscle from a pitcher's drive leg (ipsilateral side of the UCLR) or landing leg (contralateral side of the UCLR) is more active during the pitching motion. We hypothesized that the landing leg semitendinosus will be more electromyographically active than the drive leg. Healthy, elite male pitchers aged 16-21 years were recruited. Sixteen pitchers (average age, 17.6 ± 1.6 years; 67% threw right handed) underwent electromyographic analysis. Pitchers threw 5 fastballs at 100% effort from the wind-up with electromyographic analysis of every pitch. Activation of the semitendinosus and biceps femoris in both legs was compared within pitchers and between pitchers. Hamstring activity was higher in the drive leg than in the landing leg during each phase and in sum, although the difference was significant only during the double support phase (P = .021). On within-pitcher analysis, 10 of 16 pitchers had significantly more sum hamstring activity in the drive leg than in the landing leg, while only 4 of 16 had more activity in the landing leg (P = .043). During the baseball pitch, muscle activity of the semitendinosus was higher in the drive leg than in the landing leg in most pitchers. Surgeons performing UCLR using hamstring autograft should consider harvesting the graft from the pitcher's landing leg to minimize disruption to the athlete's pitching motion. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Meddeler, Bart M.; Hoogeboom, Thomas J.; Nijhuis-van der Sanden, Maria W. G.; van Cingel, Robert E. H.
2017-01-01
Context Since decades leg dominance is suggested to be important in rehabilitation and return to play in athletes with anterior cruciate ligament injuries. However, an ideal method to determine leg dominance in relation to task performance is still lacking. Objective To test the agreement between self-reported and observed leg dominance in bilateral mobilizing and unilateral stabilizing tasks, and to assess whether the dominant leg switches between bilateral mobilizing tasks and unilateral stabilizing tasks. Design Cross-sectional study. Participants Forty-one healthy adults: 21 men aged 36 ± 17 years old and 20 women aged 36 ±15 years old. Measurement and analysis Participants self-reported leg dominance in the Waterloo Footedness Questionnaire-Revised (WFQ-R), and leg dominance was observed during performance of four bilateral mobilizing tasks and two unilateral stabilizing tasks. Descriptive statistics and crosstabs were used to report the percentages of agreement. Results The leg used to kick a ball had 100% agreement between the self-reported and observed dominant leg for both men and women. The dominant leg in kicking a ball and standing on one leg was the same in 66.7% of the men and 85.0% of the women. The agreement with jumping with one leg was lower: 47.6% for men and 70.0% for women. Conclusions It is appropriate to ask healthy adults: “If you would shoot a ball on a target, which leg would you use to shoot the ball?” to determine leg dominance in bilateral mobilizing tasks. However, a considerable number of the participants switched the dominant leg in a unilateral stabilizing task. PMID:29287067
Single-leg squats can predict leg alignment in dancers performing ballet movements in "turnout".
Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L
2016-01-01
The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve "turning out" or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in "turned out" postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat.
Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”
Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L
2016-01-01
The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. PMID:27895518
Improved antioxidative protection in winter swimmers.
Siems, W G; Brenke, R; Sommerburg, O; Grune, T
1999-04-01
Adaptation to oxidative stress is an improved ability to resist the damaging effects of reactive oxygen species, resulting from pre-exposure to a lower dose. Changes in uric acid and glutathione levels during ice-bathing suggest that the intensive voluntary short-term cold exposure of winter swimming produces oxidative stress. We investigated whether the repeated oxidative stress in winter swimmers results in improved antioxidative adaptation. We obtained venous blood samples from winter swimmers and determined important components of the antioxidative defense system in the erythrocytes or blood plasma: reduced and oxidized glutathione (GSH and GSSG), and the activities of superoxide dismutase (SOD), glutathione peroxidase (GPx) and catalase (Cat). The control group consisted of healthy people who had never participated in winter swimming. The baseline concentration of GSH and the activities of erythrocytic SOD and Cat, were higher in winter swimmers. We interpret this as an adaptative response to repeated oxidative stress, and postulate it as a new basic molecular mechanism of increased tolerance to environmental stress.
Loss of legs: is it or not a handicap for an orb-weaving spider?
NASA Astrophysics Data System (ADS)
Pasquet, Alain; Anotaux, Mylène; Leborgne, Raymond
2011-07-01
Leg loss is a common phenomenon in spiders, and according to the species 5% to 40% of the adults can present at least one missing leg. There is no possibility of regeneration after adult moult and the animal must manage with its missing appendages until its death. With the loss of one or more legs, female orb-weaving spiders can be penalized twice: firstly, because the legs are necessary for web construction and secondly, the legs are essential for the control of the prey after its interception by the web. During development, spiders may be also penalized because regeneration has energetic costs that take away resources for survival, growth and reproduction. All these consequences should influence negatively the development of the spider and thus its fitness. We investigated the impact of leg loss in the orb-weaving spider, Zygiella x-notata by studying its frequency in a natural population and web building and prey capture behaviours in laboratory. In field populations, 9.5% to 13%, of the adult females presented the loss of one or more legs; the majority of individuals had lost only one leg (in 48% of cases, a first one). Leg loss seems to affect all the adult spiders, as there is no difference of mass between intact spiders and those with missing leg. Data obtained with laboratory-reared spiders, showed that the loss of legs due to the moult is rare (less than 1%). Considering changes in web design, spiders with missing legs decreased their silk investment, increased the distance between spiral turns but did not change the capture surface of the web. Under our laboratory experimental conditions, spiders with one or two lost legs did not present any difference in prey capture efficiency. In laboratory conditions, spiders with lost leg(s) did not show any difference in egg sac production or in longevity (adult lifespan) compared to intact spiders.
Bogdanis, Gregory C; Tsoukos, Athanasios; Kaloheri, Olga; Terzis, Gerasimos; Veligekas, Panagiotis; Brown, Lee E
2017-04-18
This study compared the effects of unilateral and bilateral plyometric training on single and double-leg jumping performance, maximal strength and rate of force development (RFD). Fifteen moderately trained subjects were randomly assigned to either a unilateral (U, n=7) or bilateral group (B, n=8). Both groups performed maximal effort plyometric leg exercises two times per week for 6 weeks. The B group performed all exercises with both legs, while the U group performed half the repetitions with each leg, so that total exercise volume was the same. Jumping performance was assessed by countermovement jumps (CMJ) and drop jumps (DJ), while maximal isometric leg press strength and RFD were measured before and after training for each leg separately and both legs together. CMJ improvement with both legs was not significantly different between U (12.1±7.2%) and B (11.0±5.5%) groups. However, the sum of right and left leg CMJ only improved in the U group (19.0±7.1%, p<0.001) and was unchanged in the B group (3.4±8.4%, p=0.80). Maximal isometric leg press force with both legs was increased similarly between groups (B: 20.1±6.5%, U: 19.9±6.2%). However, the sum of right and left leg maximal force increased more in U compared to B group (23.8±9.1% vs. 11.9±6.2%, p=0.009, respectively). Similarly, the sum of right and left leg RFD0-50 and RFD0-100 were improved only in the U group (34-36%, p<0.01). Unilateral plyometric training was more effective at increasing both single and double-leg jumping performance, isometric leg press maximal force and RFD when compared to bilateral training.
Ong, M L; Ng, E Y K
2005-12-01
In the lower brain, body temperature is continually being regulated almost flawlessly despite huge fluctuations in ambient and physiological conditions that constantly threaten the well-being of the body. The underlying control problem defining thermal homeostasis is one of great enormity: Many systems and sub-systems are involved in temperature regulation and physiological processes are intrinsically complex and intertwined. Thus the defining control system has to take into account the complications of nonlinearities, system uncertainties, delayed feedback loops as well as internal and external disturbances. In this paper, we propose a self-tuning adaptive thermal controller based upon Hebbian feedback covariance learning where the system is to be regulated continually to best suit its environment. This hypothesis is supported in part by postulations of the presence of adaptive optimization behavior in biological systems of certain organisms which face limited resources vital for survival. We demonstrate the use of Hebbian feedback covariance learning as a possible self-adaptive controller in body temperature regulation. The model postulates an important role of Hebbian covariance adaptation as a means of reinforcement learning in the thermal controller. The passive system is based on a simplified 2-node core and shell representation of the body, where global responses are captured. Model predictions are consistent with observed thermoregulatory responses to conditions of exercise and rest, and heat and cold stress. An important implication of the model is that optimal physiological behaviors arising from self-tuning adaptive regulation in the thermal controller may be responsible for the departure from homeostasis in abnormal states, e.g., fever. This was previously unexplained using the conventional "set-point" control theory.
The Lindsay Leg Club: supporting the NHS to provide leg ulcer care.
McKenzie, Morag
2013-06-01
Public health services will need to cope with additional demands due to an ageing society and the increasing prevalence of chronic conditions. Lower-limb ulceration is a long-term, life-changing condition and leg ulcer management can be challenging for nursing staff. The Lindsay Leg Club model is a unique partnership between community nurses, members and the local community, which provides quality of care and empowerment for patients with leg ulcers, while also supporting and educating nursing staff. The Leg Club model works in accord with core themes of Government and NHS policy. Patient feedback on the Leg Club model is positive and the Leg Clubs provide a service to members which is well accepted by patients, yet is more economically efficient than the traditional district nursing practice of home visits. Lindsay Leg Clubs provide a valuable support service to the NHS in delivering improved quality of care while improving efficiency.
Human hopping on damped surfaces: strategies for adjusting leg mechanics.
Moritz, Chet T; Farley, Claire T
2003-08-22
Fast-moving legged animals bounce along the ground with spring-like legs and agilely traverse variable terrain. Previous research has shown that hopping and running humans maintain the same bouncing movement of the body's centre of mass on a range of elastic surfaces by adjusting their spring-like legs to exactly offset changes in surface stiffness. This study investigated human hopping on damped surfaces that dissipated up to 72% of the hopper's mechanical energy. On these surfaces, the legs did not act like pure springs. Leg muscles performed up to 24-fold more net work to replace the energy lost by the damped surface. However, considering the leg and surface together, the combination appeared to behave like a constant stiffness spring on all damped surfaces. By conserving the mechanics of the leg-surface combination regardless of surface damping, hoppers also conserved centre-of-mass motions. Thus, the normal bouncing movements of the centre of mass in hopping are not always a direct result of spring-like leg behaviour. Conserving the trajectory of the centre of mass by maintaining spring-like mechanics of the leg-surface combination may be an important control strategy for fast-legged locomotion on variable terrain.
Human hopping on damped surfaces: strategies for adjusting leg mechanics.
Moritz, Chet T; Farley, Claire T
2003-01-01
Fast-moving legged animals bounce along the ground with spring-like legs and agilely traverse variable terrain. Previous research has shown that hopping and running humans maintain the same bouncing movement of the body's centre of mass on a range of elastic surfaces by adjusting their spring-like legs to exactly offset changes in surface stiffness. This study investigated human hopping on damped surfaces that dissipated up to 72% of the hopper's mechanical energy. On these surfaces, the legs did not act like pure springs. Leg muscles performed up to 24-fold more net work to replace the energy lost by the damped surface. However, considering the leg and surface together, the combination appeared to behave like a constant stiffness spring on all damped surfaces. By conserving the mechanics of the leg-surface combination regardless of surface damping, hoppers also conserved centre-of-mass motions. Thus, the normal bouncing movements of the centre of mass in hopping are not always a direct result of spring-like leg behaviour. Conserving the trajectory of the centre of mass by maintaining spring-like mechanics of the leg-surface combination may be an important control strategy for fast-legged locomotion on variable terrain. PMID:12965003
A comparison and update of direct kinematic-kinetic models of leg stiffness in human running.
Liew, Bernard X W; Morris, Susan; Masters, Ashleigh; Netto, Kevin
2017-11-07
Direct kinematic-kinetic modelling currently represents the "Gold-standard" in leg stiffness quantification during three-dimensional (3D) motion capture experiments. However, the medial-lateral components of ground reaction force and leg length have been neglected in current leg stiffness formulations. It is unknown if accounting for all 3D would alter healthy biologic estimates of leg stiffness, compared to present direct modelling methods. This study compared running leg stiffness derived from a new method (multiplanar method) which includes all three Cartesian axes, against current methods which either only include the vertical axis (line method) or only the plane of progression (uniplanar method). Twenty healthy female runners performed shod overground running at 5.0 m/s. Three-dimensional motion capture and synchronised in-ground force plates were used to track the change in length of the leg vector (hip joint centre to centre of pressure) and resultant projected ground reaction force. Leg stiffness was expressed as dimensionless units, as a percentage of an individual's bodyweight divided by standing leg length (BW/LL). Leg stiffness using the line method was larger than the uniplanar method by 15.6%BW/LL (P < .001), and multiplanar method by 24.2%BW/LL (P < .001). Leg stiffness from the uniplanar method was larger than the multiplanar method by 8.5%BW/LL (6.5 kN/m) (P < .001). The inclusion of medial-lateral components significantly increased leg deformation magnitude, accounting for the reduction in leg stiffness estimate with the multiplanar method. Given that limb movements typically occur in 3D, the new multiplanar method provides the most complete accounting of all force and length components in leg stiffness calculation. Copyright © 2017 Elsevier Ltd. All rights reserved.
A Simple Lab Exercise Demonstrating Koch's Postulates.
ERIC Educational Resources Information Center
Fulton, Michael M.
1981-01-01
Describes a laboratory exercise which applies Koch's Postulates to a plant disease, bacterial speck. Includes an explanation of Koch's Postulate, list of equipment needed, advance preparation, outline of the three-week activity, and variations of the laboratory exercise. (DS)
Graduated Compression Stockings for Runners: Friend, Foe, or Fake?
Bovenschen, H. Jorn; te Booij, Mariëlle; van der Vleuten, Carine J. M.
2013-01-01
Objective: To assess the effect of graduated compression stockings (GCS) on lower leg volume and leg complaints in runners during and after exercise. Design: Cross-sectional study. Setting: Radboud University Nijmegen Medical Centre and an outdoor running track in Nijmegen, The Netherlands. Patients or Other Participants: Thirteen Dutch trained recreational runners. Intervention(s): Participants used a GCS on 1 leg during running. Main Outcome Measures: (1) Lower leg volume of both legs was measured at baseline, directly after running, and at 5 minutes and 30 minutes after running using a validated perometer. (2) Leg complaints were reported on questionnaires at set intervals. Results: (1) In both experiments, the legs with GCS showed a reduction in mean (± SEM) leg volume directly after running, as compared with the leg without GCS: −14.1 ± 7.6 mL (P = .04) for the 10-km running track and −53.5 ± 17.8 mL (P = .03) for the maximum exercise test. This effect was not observed at 5 and 30 minutes after running. (2) No differences in leg complaints were reported in either experiment. Conclusions: The GCS prevented an increase in leg volume just after the running exercise. However, this result was not accompanied by a reduction in subjective questionnaire-reported leg complaints. The practical consequences of the present findings need further study. PMID:23672387
Inaba, Ryoichi; Kurokawa, Junichi; Mirbod, Seyed Mohammad
2009-07-01
To help making comfortable workplaces and to prevent health disorders induced by the exposure to moderate cold in two different groups of out-door workers, we conducted a survey to compare subjective symptoms and cold prevention measures in winter between traffic control workers and construction workers. The subjects of this study were 98 male traffic control workers and 149 male workers engaged in building construction. Work loads of traffic control workers and construction workers were estimated at RMR1-2 and RMR2-4, respectively. All subjects were asked to complete a self-administered questionnaire covering age, occupational career, working figure, present illness, past history of diseases, individual preventive measures to the cold, subjective symptoms in the winter (43 items) and subjective symptoms occurred during daytime working in the winter (6 items). In two parts of the construction workplaces (the place where a morning assembly was held and on the 7th floor of the construction site) dry bulb, wet bulb and globe temperatures were measured in January. Windchill Index (kcal/cm,(2) x h) was calculated by the measured dry bulb temperature and wind velocity. Mean values of dry bulb temperature between 9:00 and 16:30 in the place where a morning assembly was held for three days were between 4.8 +/- 1.2 degrees C at 9:00 am and 9.3 +/- 1.1 degrees C at noon. Mean values of Windchill Index in the place where a morning assembly was held were between 490.8+/-23.9 kcal/cm(2) x h at 9:30 am and 608.2+/-47.3 kcal/cm(2) x h at 2:30 pm. Occupational career, monthly working days, daily working hours, one way commuting hours, and daily smoking numbers of the traffic control workers were significantly shorter than the construction workers (p<0.01). There were no significant differences in the prevalence of chillness in the arms and legs between the traffic control workers (5.1%) and the construction workers (0.7%). Prevalence of wearing a warm underwear, body warmer, warm trousers, underpants, warm socks, shoe warmer and muffler in the traffic control workers were significantly higher than the construction workers. The subjective symptoms in winter complained most frequently were shoulder stiffness (51.0%), finger cold sensation (50.0%) and neck stiffness (48.0%) in the traffic control workers, and were easy to get fatigued (49.0%), lumbago (48.3%) and finger cold sensation (47.7%) in the construction workers. On the basis of the results obtained, it is clearly shown that the two groups are at the risk of disorders due to their working environment. Therefore, these workers are needed to undergo occupational health programs for prevention of cold exposure disorders. Applications of preventive countermeasures for both groups are discussed.
77 FR 21969 - Export Trade Certificate of Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... plans to export Chicken leg quarters, (or parts of chicken leg quarters, including legs or thighs..., classifiable under HTS 0207.13.99, 0207.14.99 and 1602.32.00. Export Markets Chicken leg quarters for which... shall offer TRQ Certificates for duty-free shipments of chicken leg quarters to the Republic of Panama...
Kinematic and kinetic analysis of the fouetté turn in classical ballet.
Imura, Akiko; Iino, Yoichi; Kojima, Takeji
2010-11-01
The fouetté turn in classical ballet dancing is a continuous turn with the whipping of the gesture leg and the arms and the bending and stretching of the supporting leg. The knowledge of the movement intensities of both legs for the turn would be favorable for the conditioning of the dancer's body. The purpose of this study was to estimate the intensities. The hypothesis of this study was that the intensities were higher in the supporting leg than in the gesture leg. The joint torques of both legs were determined in the turns performed by seven experienced female classical ballet dancers with inverse dynamics using three high-speed cine cameras and a force platform. The hip abductor torque, knee extensor and plantar flexor torques of the supporting leg were estimated to be exerted up to their maximum levels and the peaks of the torques were larger than the peaks of their matching torques of the gesture leg. Thus, the hypothesis was partly supported. Training of the supporting leg rather than the gesture leg would help ballet dancers perform many revolutions of the fouetté turn continuously.
Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material
NASA Technical Reports Server (NTRS)
Firdosy, Samad A.; Chun-Yip Li, Billy; Ravi, Vilupanur A.; Fleurial, Jean-Pierre; Caillat, Thierry; Anjunyan, Harut
2013-01-01
Next-generation high-temperature thermoelectric-power-generating devices will employ segmented architectures and will have to reliably withstand thermally induced mechanical stresses produced during component fabrication, device assembly, and operation. Thermoelectric materials have typically poor mechanical strength, exhibit brittle behavior, and possess a wide range of coefficient of thermal expansion (CTE) values. As a result, the direct bonding at elevated temperatures of these materials to each other to produce segmented leg components is difficult, and often results in localized microcracking at interfaces and mec hanical failure due to the stresses that arise from the CTE mismatch between the various materials. Even in the absence of full mechanical failure, degraded interfaces can lead to increased electrical and thermal resistances, which adversely impact conversion efficiency and power output. The proposed solution is the insertion of a mechanically compliant layer, with high electrical and thermal conductivity, between the low- and high-temperature segments to relieve thermomechanical stresses during device fabrication and operation. This composite material can be used as a stress-relieving layer between the thermoelectric segments and/or between a thermoelectric segment and a hot- or cold-side interconnect material. The material also can be used as a compliant hot shoe. Nickel-coated graphite powders were hot-pressed to form a nickel-graphite composite material. A freestanding thermoelectric segmented leg was fabricated by brazing the compliant pad layer between the high-temperature p- Zintl and low-temperature p-SKD TE segments using Cu-Ag braze foils. The segmented leg stack was heated in vacuum under a compressive load to achieve bonding. The novelty of the innovation is the use of composite material that re duces the thermomechanical stresses en - countered in the construction of high-efficiency, high-temperature therm - o-electric devices. The compliant pad enables the bonding of dissimilar thermoelectric materials while maintaining the desired electrical and thermal properties essential for efficient device operation. The modulus, CTE, electrical, and thermal conductances of the composite can be controlled by varying the ratio of nickel to graphite.
Leg size and muscle functions associated with leg compliance
NASA Technical Reports Server (NTRS)
Convertino, Victor A.; Doerr, Donald F.; Flores, Jose F.; Hoffler, G. Wyckliffe; Buchanan, Paul
1988-01-01
The relationship between the leg compliance and factors related to the size of leg muscle and to physical fitness was investigated in ten healthy subjects. Vascular compliance of the leg, as determined by a mercury strain gauge, was found to be not significantly correlated with any variables associated with physical fitness per se (e.g., peak O2 uptake, calf strength, age, body weight, or body composition. On the other hand, leg compliance correlated with the calf cross-sectional area (CSA) and the calculated calf volume, with the CSA of calf muscle being the most dominant contributing factor (while fat and bone were poor predicators). It is suggested that leg compliance can be lowered by increasing calf muscle mass, thus providing structural support to limit the expansion of leg veins.
Frost, John S.; Brandt, Randolph J.; Hebert, Peter; Al Taher, Omar
2015-10-06
An interconnect includes a first set of connector pads, a second set of connector pads, and a continuous central portion. A first plurality of legs extends at a first angle from the continuous central portion. Each leg of the first plurality of legs is connected to a connector pad of a first set of connector pads. A second plurality of legs extends at a second angle from the continuous central portion. Each leg of the second plurality of legs is connected to a connector pad of the second set of connector pads. Gaps are defined between legs. The gaps enable movement of the first set of connector pads relative to the second set of connector pads.
NASA Technical Reports Server (NTRS)
Behar, Alberto E. (Inventor); Marzwell, Neville I. (Inventor); Wall, Jonathan N. (Inventor); Poole, Michael D. (Inventor)
2011-01-01
A robot and robot system that are capable of functioning in a zero-gravity environment are provided. The robot can include a body having a longitudinal axis and having a control unit and a power source. The robot can include a first leg pair including a first leg and a second leg. Each leg of the first leg pair can be pivotally attached to the body and constrained to pivot in a first leg pair plane that is substantially perpendicular to the longitudinal axis of the body.
Kinematic comparison of the preferred and non-preferred foot punt kick.
Ball, Kevin A
2011-11-01
Kicking with the non-preferred leg is important in Australian Football and becoming important in the rugby codes. The aim of this study was to examine differences between preferred and non-preferred leg kicking in the drop punt kick. Seventeen elite Australian Football players performed kicks with the preferred and non-preferred leg. Optotrak Certus collected kinematic data of the kick leg and pelvis (200 Hz) from kick leg toe-off until ball contact. Foot speed, knee and shank angular velocity at ball contact, and pelvis range of motion were significantly larger for the preferred leg (P < 0.05). In contrast, hip and thigh angular velocity at ball contact and hip range of motion were significantly larger for the non-preferred leg. This indicates different movement patterns, with preferred-leg kicks making greater use of the pelvis, knee, and shank while non-preferred leg kicks rely relatively more on the hip and thigh (P < 0.05). Reasons for this difference might be due to locking degrees of freedom or sub-optimal sequencing in the non-preferred leg. The thigh-knee continuum identified by Ball ( 2008 ) was also evident in this study. Findings have implications for training non-preferred leg kicking for performance and injury prevention.
Open-split interface for mass spectrometers
Diehl, John W.
1991-01-01
An open-split interface includes a connector body having four leg members projecting therefrom within a single plane, the first and third legs being coaxial and the second and fourth legs being coaxial. A tubular aperture extends through the first and third legs and a second tubular aperture extends through the second and fourth legs, connecting at a juncture within the center of the connector body. A fifth leg projects from the connector body and has a third tubular aperture extending therethrough to the juncture of the first and second tubular apertures. A capillary column extends from a gas chromatograph into the third leg with its end adjacent the juncture. A flow restrictor tube extends from a mass spectrometer through the first tubular aperture in the first and third legs and into the capillary columnm end, so as to project beyond the end of the third leg within the capillary column. An annular gap between the tube and column allows excess effluent to pass to the juncture. A pair of short capillary columns extend from separate detectors into the second tubular aperture in the second and fourth legs, and are oriented with their ends spaced slightly from the first capillary column end. A sweep flow tube is mounted in the fifth leg so as to supply a helium sweep flow to the juncture.
The Leg Club model: a survey of staff and members' perceptions of this model of care.
Stephen-Haynes, J
2010-09-01
To determine the Leg Club members' perceptions of the Leg Club as a model for delivery of service. An explorative qualitative approach was used. All members and staff at two Leg Clubs in the UK were invited to participate. They were asked to nominate five key words that described their views of the Leg Club model of care. The researcher and a research supervisor then counted them and decided on categories. Members' themes were verified by 10 randomly chosen Leg Club members and staff themes by five randomly chosen staff. All of the 85 Leg Club members and 15 staff approached agreed to take part. Categories identified for the Leg Club members were: sociability, enabling, knowledge and experience, interpersonal relationships, caring and quality. Categories identified for Leg Club staff were: camaraderie, education, empowerment, sociability and tiredness. These results indicate that the community Leg Club environment provides benefits in addition to those of guidelines, wound care expertise and evidence-based care. While the small sample size limits the generalisability of these exploratory data, the results identify the positive views of Leg Club members and highlights the need for further research. Similar data is not available for other health care delivery methods, so this also warrants further exploration.
Increase in Leg Stiffness Reduces Joint Work During Backpack Carriage Running at Slow Velocities.
Liew, Bernard; Netto, Kevin; Morris, Susan
2017-10-01
Optimal tuning of leg stiffness has been associated with better running economy. Running with a load is energetically expensive, which could have a significant impact on athletic performance where backpack carriage is involved. The purpose of this study was to investigate the impact of load magnitude and velocity on leg stiffness. We also explored the relationship between leg stiffness and running joint work. Thirty-one healthy participants ran overground at 3 velocities (3.0, 4.0, 5.0 m·s -1 ), whilst carrying 3 load magnitudes (0%, 10%, 20% weight). Leg stiffness was derived using the direct kinetic-kinematic method. Joint work data was previously reported in a separate study. Linear models were used to establish relationships between leg stiffness and load magnitude, velocity, and joint work. Our results found that leg stiffness did not increase with load magnitude. Increased leg stiffness was associated with reduced total joint work at 3.0 m·s -1 , but not at faster velocities. The association between leg stiffness and joint work at slower velocities could be due to an optimal covariation between skeletal and muscular components of leg stiffness, and limb attack angle. When running at a relatively comfortable velocity, greater leg stiffness may reflect a more energy efficient running pattern.
Lin, Chia-Wei; Su, Fong-Chin; Wu, Hong-Wen; Lin, Cheng-Feng
2013-01-01
Turns (pirouettes) are an important movement in ballet and may be affected by "lateral bias". This study investigated physiological differences exhibited by experienced and novice dancers, respectively, when performing pirouette with dominant and non-dominant leg supports, respectively. Thirteen novice and 13 experienced dancers performed turns on dominant or non-dominant legs. The maximum ankle plantarflexion, knee extension and hip extension were measured during the single-leg support phase. The inclination angle of rotation axis is the angle between instantaneous rotation axis and global vertical axis in the early single-leg support phase. Both groups exhibited a greater hip extension, knee extension, and ankle plantarflexion when performing a turn on the non-dominant leg. For experienced dancers, the inclination angle of rotation axis during the pre-swing phase was generally smaller for dominant leg support than non-dominant leg. However, no significant difference was found in inclination angle of rotation axis of novice dancers. For experienced dancers, an improved performance is obtained when using the dominant leg for support. By contrast, for novice dancers, the performance is independent of choice of support leg. The significant lateral bias in experienced dancers indicates the possible influence of training. That is, repetitive rehearsal on the preferred leg strengthens the impact of side dominance in experienced dancers.
Brambrink, J K; Fluckey, J D; Hickey, M S; Craig, B W
1997-11-01
The 18 h post-exercise glucose and insulin responses of six male and six female subjects were measured following one- or two-leg cycling to determine the influence of muscle mass involvement and work. Each subject performed three exercise trials on a Cybex Met 100 cycle ergometer: (1) two-leg exercise for 30 min at 60% of the two-leg VO2 max; (2) one-leg exercise for 30 min at 60% of one-leg VO2 max; and (3) one-leg exercise (one-leg TW) at 60% of the one-leg VO2 max with the total work performed equal to that of the two-leg trial (duration approximately 50 min). These trials were preceded by 2 days of inactivity and followed by an 18 h post-exercise 75 g oral glucose tolerance test (OGTT). The glucose response during the baseline OGTT demonstrated that the subjects had normal glucose tolerance with fasting serum glucose levels of 5.1 mM, and 1 and 2 h serum glucose less than 7.8 mM, respectively. The 18 h post-exercise glucose responses were significantly lower following the two-leg trial (P < 0.05), with the area under the curve values being 129.9 mM h-1 less than the resting control level. The 18 h post-exercise insulin AUC response of the two-leg trial was significantly lower than either of the one-leg responses (14.7 pM below the one-leg and 5.0 pM below the one-leg TW) but was not associated with a change in C-peptide. The 18 h post-exercise insulin levels of the one-leg and one-leg TW trials were above or near the resting control values, but were not accompanied by a significant change in C-peptide. In conclusion, the data presented here show that the amount of muscle tissue utilized during an exercise bout can influence both the glucose and insulin responses, whereas the amount of total work employed during the exercise had no effect on either of these parameters.
A Biomechanical Comparison of Single-Leg Landing and Unplanned Sidestepping.
Chinnasee, Chamnan; Weir, Gillian; Sasimontonkul, Siriporn; Alderson, Jacqueline; Donnelly, Cyril
2018-06-14
Unplanned sidestepping and single-leg landing have both been used to screen athletes for injury risk in sport. The aim of this study was to directly compare the lower limb mechanics of three single-leg landing tasks and an unplanned sidestepping task. Thirteen elite female team sport athletes completed a series of non-contact single-leg drop landings, single-leg countermovement jumps, single-leg jump landings and unplanned sidestepping in a randomized counterbalanced design. Three dimensional kinematics (250 Hz) and ground reaction force (2,000 Hz) data with a participant specific lower limb skeletal model were used to calculate and compare hip, knee and ankle joint kinematics, peak joint moments, instantaneous joint power and joint work during the weight acceptance phase of each sporting task (α=0.05). Peak knee joint moments and relevant injury risk thresholds were used to classify each athlete's anterior cruciate ligament injury risk during unplanned sidestepping and single-leg jump landing. Results showed that peak joint moments, power and work were greater during the single-leg jump landing task when compared to the single-leg drop landings and single-leg countermovement jumps tasks. Peak frontal and sagittal plane knee joint moments, knee joint power, as well as hip and knee joint work were greater during unplanned sidestepping when compared to the landing tasks. Peak ankle joint moments, power and work were greater during the landing tasks when compared to unplanned sidestepping. For 4 of the 13 athletes tested, their anterior cruciate ligament injury risk classification changed depending on whether they performed an unplanned sidestepping or single-leg jump landing testing procedure. To summarize, a single-leg jump landing testing procedure places a larger mechanical on the ankle joint when compared to single-leg drop landings, single-leg countermovement jumps and unplanned sidestepping. An unplanned sidestepping testing procedure places a larger mechanical demand on the knee joint when compared to single-leg landing tasks. Both unplanned sidestepping and single-leg jump landing testing procedures are recommended for classifying an athlete's anterior cruciate ligament injury risk in sport. © Georg Thieme Verlag KG Stuttgart · New York.
Varma, Venugopal K.
2001-01-01
An actuator for cycling between first and second positions includes a first shaped memory alloy (SMA) leg, a second SMA leg. At least one heating/cooling device is thermally connected to at least one of the legs, each heating/cooling device capable of simultaneously heating one leg while cooling the other leg. The heating/cooling devices can include thermoelectric and/or thermoionic elements.
Erbrech, Aude; Robin, Jean-Patrice; Guérin, Nathalie; Groscolas, René; Gilbert, Caroline; Martrette, Jean-Marc
2011-06-01
Continuous growth, associated with a steady parental food supply, is a general pattern in offspring development. So that young chicks can acquire their locomotor independence, this period is usually marked by a fast maturation of muscles, during which different myosin heavy chain (MyHC) isoforms are expressed. However, parental food provisioning may fluctuate seasonally, and offspring therefore face a challenge to ensure the necessary maturation of their tissues when energy is limited. To address this trade-off we investigated muscle maturation in both the pectoral and pelvic girdles of king penguin chicks. This species has an exceptionally long rearing period (1 year), which is prolonged when parental food provisioning is drastically reduced during the sub-Antarctic winter. Approximately 1 month post hatching, chicks acquire a functional pedestrian locomotion, which uses pelvic muscles, whereas swimming, which uses the pectoral muscles, only occurs 1 year later. We therefore tested the hypothesis that the MyHC content of the leg muscles reaches a mature state before those of the pectoral muscles. We found that leg muscle MyHC composition changed with the progressive acquisition of pedestrian locomotion, whereas pectoral muscle fibres reached their mature MyHC profile as early as hatching. Contrary to our predictions, the acquisition of the adult profile in pectoral muscles could be related to an early maturation of the contractile muscular proteins, presumably associated with early thermoregulatory capacities of chicks, necessary for survival in their cold environment. This differential maturation appears to reconcile both the locomotor and environmental constraints of king penguin chicks during growth.
Diurnal and nocturnal skin temperature regulation in chronic complex regional pain syndrome.
Schilder, Johanna C M; Niehof, Sjoerd P; Marinus, Johan; van Hilten, Jacobus J
2015-03-01
Skin temperature changes due to vasomotor disturbances are important features of complex regional pain syndrome (CRPS). Because this phenomenon has only been studied under controlled conditions, information on daily circadian variability is lacking. Also, studies in chronic CRPS patients with abnormal posturing, in which coldness of the affected extremity is more common, do not exist. We examined the response to external heating as well as circadian temperature changes over several days in the affected legs of 14 chronic CRPS patients with abnormal posturing and 17 controls. Skin temperatures were recorded hourly for 14 days using wireless sensors. Although the patients' affected extremities were significantly colder before external heating, the vasodilatory response was similar in the 2 groups. Additionally, median skin temperature differences between both legs and their variability was larger in patients than in controls during the day, but not during the night. These findings indicate that the mechanisms underlying impaired skin circulation in CRPS during daytime are reversible under certain circumstances. The large variation in skin temperature differences during the day questions the validity of using a single measurement in the diagnosis of CRPS, and our results indicate that only temperature differences >1.0 °C should be considered to reflect vasomotor disturbances. This article shows that chronic CRPS patients have a normal vasodilatory response to external heating and that skin temperature differences between the affected and unaffected lower limbs, which were highly variable during daytime, disappeared during sleep. This indicates that part of the vasomotor regulation in these patients is still functional. Copyright © 2015 American Pain Society. Published by Elsevier Inc. All rights reserved.
Non-Intrusive Velocity Measurements with MTV During DCC Event in the HTTF
NASA Technical Reports Server (NTRS)
Andre, M. A.; Bardet, P. M.; Cadell, S. R.; Woods, B.; Burns, R. A.; Danehy, P. M.
2017-01-01
Velocity profiles are measured using molecular tagging velocimetry (MTV) in the high temperature test facility (HTTF) at Oregon State University during a depressurized conduction cooldown (DCC) event. The HTTF is a quarter scale electrically heated nuclear reactor simulator designed to replicate various accident scenarios. During a DCC, a double ended guillotine break results in the reactor pressure vessel (RPV) depressurizing into the reactor cavity and ultimately leading to air ingress in the reactor core (lock-exchange and gas diffusion). It is critical to understand the resulting buoyancy-driven flow to characterize the reactor self-cooling capacity through natural circulation. During tests conducted at ambient pressure and temperature, the RPV containing helium is opened (via the hot and cold legs) to a large vessel filled with nitrogen to simulate the atmosphere. The velocity profile on the hot leg pipe centerline is recorded at 10 Hz with MTV based on NO tracers. The precision of the velocimetry was measured to be 0.02 m/s in quiescent flow prior to the tests. A helium flow from the RPV is initially observed in the top quarter of the pipe. During the first 20 seconds of the event, helium flows out of the RPV with a maximum velocity below 2 m/s. The velocity profile transitions from parabolic to linear in character and decays slowly over the rest of the recording; peak velocities of 0.2 m/s are observed after 30 min. A counter-flow of nitrogen is also observed intermittently, which occurs at lower velocities (>0.1 m/s).
A load-based mechanism for inter-leg coordination in insects
2017-01-01
Animals rely on an adaptive coordination of legs during walking. However, which specific mechanisms underlie coordination during natural locomotion remains largely unknown. One hypothesis is that legs can be coordinated mechanically based on a transfer of body load from one leg to another. To test this hypothesis, we simultaneously recorded leg kinematics, ground reaction forces and muscle activity in freely walking stick insects (Carausius morosus). Based on torque calculations, we show that load sensors (campaniform sensilla) at the proximal leg joints are well suited to encode the unloading of the leg in individual steps. The unloading coincides with a switch from stance to swing muscle activity, consistent with a load reflex promoting the stance-to-swing transition. Moreover, a mechanical simulation reveals that the unloading can be ascribed to the loading of a specific neighbouring leg, making it exploitable for inter-leg coordination. We propose that mechanically mediated load-based coordination is used across insects analogously to mammals. PMID:29187626
The Relationship among Leg Strength, Leg Power and Alpine Skiing Success.
ERIC Educational Resources Information Center
Gettman, Larry R.; Huckel, Jack R.
The purpose of this study was to relate leg strength and power to alpine skiing success as measured by FIS points. Isometric leg strength was represented by the knee extension test described by Clarke. Leg power was measured by the vertical jump test and the Margaria-Kalamen stair run. Results in the strength and power tests were correlated with…
Chang, Young-Hui; Ting, Lena H
2017-05-01
Flamingos (Phoenicopteridae) often stand and sleep on one leg for long periods, but it is unknown how much active muscle contractile force they use for the mechanical demands of standing on one leg: body weight support and maintaining balance. First, we demonstrated that flamingo cadavers could passively support body weight on one leg without any muscle activity while adopting a stable, unchanging, joint posture resembling that seen in live flamingos. By contrast, the cadaveric flamingo could not be stably held in a two-legged pose, suggesting a greater necessity for active muscle force to stabilize two-legged versus one-legged postures. Our results suggest that flamingos engage a passively engaged gravitational stay apparatus (proximally located) for weight support during one-legged standing. Second, we discovered that live flamingos standing on one leg have markedly reduced body sway during quiescent versus alert behaviours, with the point of force application directly under the distal joint, reducing the need for muscular joint torque. Taken together, our results highlight the possibility that flamingos stand for long durations on one leg without exacting high muscular forces and, thus, with little energetic expenditure. © 2017 The Author(s).
High day-to-day reliability in lower leg volume measured by water displacement.
Pasley, Jeffrey D; O'Connor, Patrick J
2008-07-01
The day-to-day reliability of lower leg volume is poorly documented. This investigation determined the day-to-day reliability of lower leg volume (soleus and gastrocnemius) measured using water displacement. Thirty young adults (15 men and 15 women) had their right lower leg volume measured by water displacement on five separate occasions. The participants performed normal activities of daily living and were measured at the same time of day after being seated for 30 min. The results revealed a high day-to-day reliability for lower leg volume. The mean percentage change in lower leg volume across days compared to day 1 ranged between 0 and 0.37%. The mean within subjects coefficient of variation in lower leg volume was 0.72% and the coefficient of variation for the entire sample across days ranged from 5.66 to 6.32%. A two way mixed model intraclass correlation (30 subjects x 5 days) showed that the lower leg volume measurement was highly reliable (ICC = 0.972). Foot and total lower leg volumes showed similarly high reliability. Water displacement offers a cost effective and reliable solution for the measurement of lower leg edema across days.
Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido
2017-01-01
The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.
Warm-up Optimizes Postural Control but Requires Some Minutes of Recovery.
Paillard, Thierry; Kadri, Mohamed Abdelhafid; Nouar, Merbouha Boulahbel; Noé, Frederic
2018-05-02
Paillard, T, Kadri, MA, Nouar, MB, and Noé, F. Warm-up optimizes postural control but requires some minutes of recovery. J Strength Cond Res XX(X): 000-000, 2018-The aim was to compare monopedal postural control between the dominant leg (D-Leg) and the nondominant leg (ND-Leg) in pre- and post-warm-up conditions. Thirty healthy male sports science students were evaluated before and after a warm-up exercise (12 minutes of pedaling with an incremental effort on a cycle ergometer with a controlled workload). Monopodal postural control was assessed for the D- and ND-Legs before and immediately, 2, 5, 10, and 15 minutes after the warm-up exercise, using a force platform and calculating the displacement velocity of the center of foot pressure on the mediolateral (COPML velocity) and anteroposterior (COPAP velocity) axes. No significant difference was observed between the D-Leg and ND-Leg for both COPML and COPAP velocity in all the periods. In comparison with pre-warm-up, COPML decreased after 15-minute and 10-minute recovery periods for the D-Leg and the ND-Leg, respectively (p < 0.05), whereas COPAP decreased after 10-minute and 15-minute recovery periods (p < 0.001; p < 0.01, respectively) for the D-Leg, and after a 10-minute recovery period for the ND-Leg (p < 0.001). The warm-up optimized monopedal postural control but did not make it possible to distinguish a difference between the D-Leg and the ND-Leg. Some minutes of recovery are required between the end of the whole-body warm-up exercise and the beginning of the postural test to optimize postural control. The optimal duration of recovery turns out to be about 10-15 minutes.
A springy pendulum could describe the swing leg kinetics of human walking.
Song, Hyunggwi; Park, Heewon; Park, Sukyung
2016-06-14
The dynamics of human walking during various walking conditions could be qualitatively captured by the springy legged dynamics, which have been used as a theoretical framework for bipedal robotics applications. However, the spring-loaded inverted pendulum model describes the motion of the center of mass (CoM), which combines the torso, swing and stance legs together and does not explicitly inform us as to whether the inter-limb dynamics share the springy legged dynamics characteristics of the CoM. In this study, we examined whether the swing leg dynamics could also be represented by springy mechanics and whether the swing leg stiffness shows a dependence on gait speed, as has been observed in CoM mechanics during walking. The swing leg was modeled as a spring-loaded pendulum hinged at the hip joint, which is under forward motion. The model parameters of the loaded mass were adopted from body parameters and anthropometric tables, whereas the free model parameters for the rest length of the spring and its stiffness were estimated to best match the data for the swing leg joint forces. The joint forces of the swing leg were well represented by the springy pendulum model at various walking speeds with a regression coefficient of R(2)>0.8. The swing leg stiffness increased with walking speed and was correlated with the swing frequency, which is consistent with previous observations from CoM dynamics described using the compliant leg. These results suggest that the swing leg also shares the springy dynamics, and the compliant walking model could be extended to better present swing leg dynamics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Khalaf, Majid; Brey, Richard R; Meldrum, Jeff
2013-01-01
A new leg voxel model in two different positions (straight and bent) has been developed for in vivo measurement calibration purposes. This voxel phantom is a representation of a human leg that may provide a substantial enhancement to Monte Carlo modeling because it more accurately models different geometric leg positions and the non-uniform distribution of Am throughout the leg bones instead of assuming a one-position geometry and a uniform distribution of radionuclides. This was accomplished by performing a radiochemical analysis on small sections of the leg bones from the U.S. Transuranium and Uranium Registries (USTUR) case 0846. USTUR case 0846 represents an individual who was repeatedly contaminated by Am via chronic inhalation. To construct the voxel model, high resolution (2 mm) computed tomography (CT) images of the USTUR case 0846 leg were obtained in different positions. Thirty-six (36) objects (universes) were segmented manually from the CT images using 3D-Doctor software. Bones were divided into 30 small sections with an assigned weight exactly equal to the weight of bone sections obtained from radiochemical analysis of the USTUR case 0846 leg. The segmented images were then converted into a boundary file, and the Human Monitoring Laboratory (HML) voxelizer was used to convert the boundary file into the leg voxel phantom. Excluding the surrounding air regions, the straight leg phantom consists of 592,023 voxels, while the bent leg consists of 337,567 voxels. The resulting leg voxel model is now ready for use as an MCNPX input file to simulate in vivo measurement of bone-seeking radionuclides.
Mertz, Laura; Docherty, Carrie
2012-12-01
Ballet technique classes are designed to train dancers symmetrically, but they may actually create a lateral bias. It is unknown whether dancers in general are functionally asymmetrical, or how an individual dancer's perceived imbalance between legs might manifest itself. The purpose of this study was to examine ballet dancers' lateral preference by analyzing their postural stability and ground reaction forces in fifth position when landing from dance-specific jumps. Thirty university ballet majors volunteered to participate in this study. The subjects wore their own ballet technique shoes and performed fundamental ballet jumps out of fifth position on a force plate. The force plate recorded center of pressure (COP) and ground reaction force (GRF) data. Each subject completed a laterality questionnaire that determined his or her preferred landing leg for ballet jumps, self-identified stronger leg, and self-identified leg with better balance. All statistical comparisons were made between the leg indicated on the laterality questionnaire and the other leg (i.e., if the dancer's response to a question was "left," the comparison was made with the left leg as the "preferred" leg and the right leg as the "non-preferred leg"). No significant differences were identified between the limbs in any of the analyses conducted (all statistical comparisons produced p values > 0.05). The results of this study indicate that a dancer's preferential use of one limb over the other has no bearing on GRFs or balance ability after landing jumps in ballet. Similarly, dancers' opinions of their leg characteristics (such as one leg being stronger than the other) seem not to correlate with the dancers' actual ability to absorb GRFs or to balance when landing from ballet jumps.
Engelberger, Rolf P; Blazek, Claudia; Amsler, Felix; Keo, Hong H; Baumann, Frédéric; Blättler, Werner; Baumgartner, Iris; Willenberg, Torsten
2011-10-05
Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.
Pozeg, Polona; Galli, Giulia; Blanke, Olaf
2015-01-01
Experiencing a body part as one’s own, i.e., body ownership, depends on the integration of multisensory bodily signals (including visual, tactile, and proprioceptive information) with the visual top-down signals from peripersonal space. Although it has been shown that the visuo-spatial viewpoint from where the body is seen is an important visual top-down factor for body ownership, different studies have reported diverging results. Furthermore, the role of visuo-spatial viewpoint (sometime also called first-person perspective) has only been studied for hands or the whole body, but not for the lower limbs. We thus investigated whether and how leg visuo-tactile integration and leg ownership depended on the visuo-spatial viewpoint from which the legs were seen and the anatomical similarity of the visual leg stimuli. Using a virtual leg illusion, we tested the strength of visuo-tactile integration of leg stimuli using the crossmodal congruency effect (CCE) as well as the subjective sense of leg ownership (assessed by a questionnaire). Fifteen participants viewed virtual legs or non-corporeal control objects, presented either from their habitual first-person viewpoint or from a viewpoint that was rotated by 90°(third-person viewpoint), while applying visuo-tactile stroking between the participants legs and the virtual legs shown on a head-mounted display. The data show that the first-person visuo-spatial viewpoint significantly boosts the visuo-tactile integration as well as the sense of leg ownership. Moreover, the viewpoint-dependent increment of the visuo-tactile integration was only found in the conditions when participants viewed the virtual legs (absent for control objects). These results confirm the importance of first person visuo-spatial viewpoint for the integration of visuo-tactile stimuli and extend findings from the upper extremity and the trunk to visuo-tactile integration and ownership for the legs. PMID:26635663
Operation analysis of a Chebyshev-Pantograph leg mechanism for a single DOF biped robot
NASA Astrophysics Data System (ADS)
Liang, Conghui; Ceccarelli, Marco; Takeda, Yukio
2012-12-01
In this paper, operation analysis of a Chebyshev-Pantograph leg mechanism is presented for a single degree of freedom (DOF) biped robot. The proposed leg mechanism is composed of a Chebyshev four-bar linkage and a pantograph mechanism. In contrast to general fully actuated anthropomorphic leg mechanisms, the proposed leg mechanism has peculiar features like compactness, low-cost, and easy-operation. Kinematic equations of the proposed leg mechanism are formulated for a computer oriented simulation. Simulation results show the operation performance of the proposed leg mechanism with suitable characteristics. A parametric study has been carried out to evaluate the operation performance as function of design parameters. A prototype of a single DOF biped robot equipped with two proposed leg mechanisms has been built at LARM (Laboratory of Robotics and Mechatronics). Experimental test shows practical feasible walking ability of the prototype, as well as drawbacks are discussed for the mechanical design.
Bieler, Theresa; Magnusson, Stig Peter; Christensen, Helle Elisabeth; Kjaer, Michael; Beyer, Nina
2017-07-01
To investigate between-leg differences in hip and thigh muscle strength and leg extensor power in patients with unilateral hip osteoarthritis. Further, to compare between-leg differences in knee extensor strength and leg extensor power between patients and healthy peers. Seventy-two patients (60-87 years) with radiographic and symptomatic hip osteoarthritis not awaiting hip replacement and 35 healthy peers (63-82 years) were included. Hip and thigh muscle strength and leg extensor power were measured in patients and knee extensor strength and leg extensor power in healthy. The symptomatic extremity in patients was significantly (p < 0.05, paired t-test) weaker compared with the non-symptomatic extremity for five hip muscles (8-17%), knee extensors (11%) and leg extensor power (19%). Healthy older adults had asymmetry in knee extensor strength (6%, p < 0.05) comparable to that found in patients, but had no asymmetry in leg extensor power. Patients had generalized weakening of the affected lower extremity and numerically the largest asymmetry was evident for leg extensor power. In contrast, healthy peers had no asymmetry in leg extensor power. These results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with hip osteoarthritis. Implications for Rehabilitation Even in patients with mild symptoms not awaiting hip replacement a generalized muscle weakening of the symptomatic lower extremity seems to be present. Between-leg differences in leg extensor power (force × velocity) appears to be relatively large (19%) in patients with unilateral hip osteoarthritis in contrast to healthy peers who show no asymmetry. Compared to muscle strength the relationship between functional performance and leg extensor power seems to be stronger, and more strongly related to power of the symptomatic lower extremity. Our results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with mild symptoms not awaiting hip replacement.
Kibsgård, Thomas J; Röhrl, Stephan M; Røise, Olav; Sturesson, Bengt; Stuge, Britt
2017-08-01
The Active Straight Leg Raise is a functional test used in the assessment of pelvic girdle pain, and has shown to have good validity, reliability and responsiveness. The Active Straight Leg Raise is considered to examine the patients' ability to transfer load through the pelvis. It has been hypothesized that patients with pelvic girdle pain lack the ability to stabilize the pelvic girdle, probably due to instability or increased movement of the sacroiliac joint. This study examines the movement of the sacroiliac joints during the Active Straight Leg Raise in patients with pelvic girdle pain. Tantalum markers were inserted in the dorsal sacrum and ilium of 12 patients with long-lasting pelvic girdle pain scheduled for sacroiliac joint fusion surgery. Two to three weeks later movement of the sacroiliac joints during the Active Straight Leg Raise was measured with radiostereometric analysis. Small movements were detected. There was larger movement of the sacroiliac joint of the rested leg's sacroiliac joint compared to the lifted leg's side. A mean backward rotation of 0.8° and inward tilt of 0.3° were seen in the rested leg's sacroiliac joint. The movements of the sacroiliac joints during the Active Straight Leg Raise are small. There was a small backward rotation of the innominate bone relative to sacrum on the rested leg's side. Our findings contradict an earlier understanding that a forward rotation of the lifted leg's innominate occur while performing the Active Straight Leg Raise. Copyright © 2017. Published by Elsevier Ltd.
Tazoe, Toshiki; Nakajima, Tsuyoshi; Futatsubashi, Genki; Ohtsuka, Hiroyuki; Suzuki, Shinya; Zehr, E. Paul; Komiyama, Tomoyoshi
2016-01-01
Neural interactions between regulatory systems for rhythmic arm and leg movements are an intriguing issue in locomotor neuroscience. Amplitudes of early latency cutaneous reflexes (ELCRs) in stationary arm muscles are modulated during rhythmic leg or arm cycling but not during limb positioning or voluntary contraction. This suggests that interneurons mediating ELCRs to arm muscles integrate outputs from neural systems controlling rhythmic limb movements. Alternatively, outputs could be integrated at the motoneuron and/or supraspinal levels. We examined whether a separate effect on the ELCR pathways and cortico-motoneuronal excitability during arm and leg cycling is integrated by neural elements common to the lumbo-sacral and cervical spinal cord. The subjects performed bilateral leg cycling (LEG), contralateral arm cycling (ARM), and simultaneous contralateral arm and bilateral leg cycling (A&L), while ELCRs in the wrist flexor and shoulder flexor muscles were evoked by superficial radial (SR) nerve stimulation. ELCR amplitudes were facilitated by cycling tasks and were larger during A&L than during ARM and LEG. A low stimulus intensity during ARM or LEG generated a larger ELCR during A&L than the sum of ELCRs during ARM and LEG. We confirmed this nonlinear increase in single motor unit firing probability following SR nerve stimulation during A&L. Furthermore, motor-evoked potentials following transcranial magnetic and electrical stimulation did not show nonlinear potentiation during A&L. These findings suggest the existence of a common neural element of the ELCR reflex pathway that is active only during rhythmic arm and leg movement and receives convergent input from contralateral arms and legs. PMID:26961103
Gowda, Swetha B. M.; Paranjpe, Pushkar D.; Reddy, O. Venkateswara; Thiagarajan, Devasena; Palliyil, Sudhir; Reichert, Heinrich
2018-01-01
Walking is a complex rhythmic locomotor behavior generated by sequential and periodical contraction of muscles essential for coordinated control of movements of legs and leg joints. Studies of walking in vertebrates and invertebrates have revealed that premotor neural circuitry generates a basic rhythmic pattern that is sculpted by sensory feedback and ultimately controls the amplitude and phase of the motor output to leg muscles. However, the identity and functional roles of the premotor interneurons that directly control leg motoneuron activity are poorly understood. Here we take advantage of the powerful genetic methodology available in Drosophila to investigate the role of premotor inhibition in walking by genetically suppressing inhibitory input to leg motoneurons. For this, we have developed an algorithm for automated analysis of leg motion to characterize the walking parameters of wild-type flies from high-speed video recordings. Further, we use genetic reagents for targeted RNAi knockdown of inhibitory neurotransmitter receptors in leg motoneurons together with quantitative analysis of resulting changes in leg movement parameters in freely walking Drosophila. Our findings indicate that targeted down-regulation of the GABAA receptor Rdl (Resistance to Dieldrin) in leg motoneurons results in a dramatic reduction of walking speed and step length without the loss of general leg coordination during locomotion. Genetically restricting the knockdown to the adult stage and subsets of motoneurons yields qualitatively identical results. Taken together, these findings identify GABAergic premotor inhibition of motoneurons as an important determinant of correctly coordinated leg movements and speed of walking in freely behaving Drosophila. PMID:29440493
Gowda, Swetha B M; Paranjpe, Pushkar D; Reddy, O Venkateswara; Thiagarajan, Devasena; Palliyil, Sudhir; Reichert, Heinrich; VijayRaghavan, K
2018-02-27
Walking is a complex rhythmic locomotor behavior generated by sequential and periodical contraction of muscles essential for coordinated control of movements of legs and leg joints. Studies of walking in vertebrates and invertebrates have revealed that premotor neural circuitry generates a basic rhythmic pattern that is sculpted by sensory feedback and ultimately controls the amplitude and phase of the motor output to leg muscles. However, the identity and functional roles of the premotor interneurons that directly control leg motoneuron activity are poorly understood. Here we take advantage of the powerful genetic methodology available in Drosophila to investigate the role of premotor inhibition in walking by genetically suppressing inhibitory input to leg motoneurons. For this, we have developed an algorithm for automated analysis of leg motion to characterize the walking parameters of wild-type flies from high-speed video recordings. Further, we use genetic reagents for targeted RNAi knockdown of inhibitory neurotransmitter receptors in leg motoneurons together with quantitative analysis of resulting changes in leg movement parameters in freely walking Drosophila Our findings indicate that targeted down-regulation of the GABA A receptor Rdl (Resistance to Dieldrin) in leg motoneurons results in a dramatic reduction of walking speed and step length without the loss of general leg coordination during locomotion. Genetically restricting the knockdown to the adult stage and subsets of motoneurons yields qualitatively identical results. Taken together, these findings identify GABAergic premotor inhibition of motoneurons as an important determinant of correctly coordinated leg movements and speed of walking in freely behaving Drosophila . Copyright © 2018 the Author(s). Published by PNAS.
The Benslimane's Artistic Model for Leg Beauty.
Benslimane, Fahd
2012-08-01
In 2000, the author started observing legs considered to be attractive. The goal was to have an ideal aesthetic model and compare the disparity between this model and a patient's reality. This could prove helpful during leg sculpturing to get closer to this ideal. Postoperatively, the result could then be compared to the ideal curves of the model legs and any remaining deviations from the ideal curves could be pointed out and eventually corrected in a second session. The lack of anthropometric studies of legs from the knee to the ankle led the author to select and study attractive legs to find out the common denominators of their beauty. The study consisted in analyzing the features that make legs look attractive. The legs of models in magazines were scanned and inserted into a PowerPoint program. The legs of live models, Barbie dolls, and athletes were photographed. Artistic drawings by Leonardo da Vinci were reviewed and Greek sculptures studied. Sculptures from the National Archaeological Museum of Athens were photographed and included in the PowerPoint program. This study shows that the first criterion for beautiful legs is the straightness of the leg column. Not a single attractive leg was found to deviate from the vertical, and each was in absolute continuity with the thigh. The second criterion is the similarity of curve distribution and progression from knee to ankle. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266.
Astaxanthin intake attenuates muscle atrophy caused by immobilization in rats.
Shibaguchi, Tsubasa; Yamaguchi, Yusuke; Miyaji, Nobuyuki; Yoshihara, Toshinori; Naito, Hisashi; Goto, Katsumasa; Ohmori, Daijiro; Yoshioka, Toshitada; Sugiura, Takao
2016-08-01
Astaxanthin is a carotenoid pigment and has been shown to be an effective inhibitor of oxidative damage. We tested the hypothesis that astaxanthin intake would attenuate immobilization-induced muscle atrophy in rats. Male Wistar rats (14-week old) were fed for 24 days with either astaxanthin or placebo diet. After 14 days of each experimental diet intake, the hindlimb muscles of one leg were immobilized in plantar flexion position using a plaster cast. Following 10 days of immobilization, both the atrophic and the contralateral plantaris muscles were removed and analyzed to determine the level of muscle atrophy along with measurement of the protein levels of CuZn-superoxide dismutase (CuZn-SOD) and selected proteases. Compared with placebo diet animals, the degree of muscle atrophy in response to immobilization was significantly reduced in astaxanthin diet animals. Further, astaxanthin supplementation significantly prevented the immobilization-induced increase in the expression of CuZn-SOD, cathepsin L, calpain, and ubiquitin in the atrophied muscle. These results support the postulate that dietary astaxanthin intake attenuates the rate of disuse muscle atrophy by inhibiting oxidative stress and proteolysis via three major proteolytic pathways. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Satellite DNA and cytogenetic evolution: molecular aspects and implications for man. [Kangaroo rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hatch, F.T.; Mazrimas, J.
1977-02-28
Simple, highly reiterated DNA sequences, often observed in density gradients as satellite DNAs, exist in condensed heterochromatin. This material is predominantly located at chromosomal centromeres, occasionally at telomeres, or intercalated within arms; in a few species it occupies entire chromosome arms. Satellite DNAs are a highly variable component of the genome of most higher eukaryotes, but their functions have remained speculative. The genus of kangaroo rats (Dipodomys) exhibits remarkable interspecies variations in content of three satellite DNAs, consisting of simple sequences 3 to 10 base pairs long, and in species karyotypes. A broad range of diploid-DNA content is correlated withmore » satellite-DNA content. The latter is correlated positively with predominance of biarmed over uniarmed chromosomes (high fundamental number FN) and inversely with two anatomical indices (leg-bone-length ratios) of specialization for the jumping gait. Karyotypic variation is achieved via chromosomal rearrangements, e.g., Robertsonian fusion, C-band heteromorphism, and pericentric inversion. Environmental adaptation is achieved, in part, by reassortment of gene-linkage groups and regulatory controls as a result of the chromosomal rearrangements. The foregoing relationships led to the postulation that highly reiterated DNA sequences play a supragenic, global role in environmental adaptation and the evolution of new species.« less
Giraffe Stature and Neck Elongation: Vigilance as an Evolutionary Mechanism
Williams, Edgar M.
2016-01-01
Giraffe (Giraffa camelopardalis), with their long neck and legs, are unique amongst mammals. How these features evolved is a matter of conjecture. The two leading ideas are the high browse and the sexual-selection hypotheses. While both explain many of the characteristics and the behaviour of giraffe, neither is fully supported by the available evidence. The extended viewing horizon afforded by increased height and a need to maintain horizon vigilance, as a mechanism favouring the evolution of increased height is reviewed. In giraffe, vigilance of predators whilst feeding and drinking are important survival factors, as is the ability to interact with immediate herd members, young and male suitors. The evidence regarding giraffe vigilance behaviour is sparse and suggests that over-vigilance has a negative cost, serving as a distraction to feeding. In woodland savannah, increased height allows giraffe to see further, allowing each giraffe to increase the distance between its neighbours while browsing. Increased height allows the giraffe to see the early approach of predators, as well as bull males. It is postulated that the wider panorama afforded by an increase in height and longer neck has improved survival via allowing giraffe to browse safely over wider areas, decreasing competition within groups and with other herbivores. PMID:27626454
Placzek, R; Deuretzbacher, G; Meiss, A L
2002-12-01
It is claimed in the literature that hydroxyapatite(HA)-coated screws of external fixators have superior fixation strength in bone, which is postulated to lead to a substantial decrease in loosening and infection rates. We report on a study of the maximum torque values developed while inserting and removing 30 HA-coated Schanz screws of 8 Heidelberg external fixation systems applied to the tibia to correct leg length differences and axial deformities. The infection rate was determined in accordance with defined criteria, and was found to be about 20% for the HA-coated screws. Screws without infection showed an extraction torque above insertion torque, screws with infection an extraction torque below. A significant correlation (p = 0.05) was seen between infection and decrease in fixation strength (quotient: loosening torque/tightening torque). To exclude the impact of such biological processes as osteointegration and bone remodelling, the clinical results were compared with the torques measured for coated and uncoated Schanz screws in a human cadaveric tibia. A significantly higher fixation strength in bone was found for HA-coated screws in comparison with uncoated screws (p = 0.002). These data warrant a clinical study directly comparing HA-coated and uncoated Schanz screws.
Workplace barriers encountered by employed persons with systemic sclerosis.
Poole, Janet L; Anwar, Sahar; Mendelson, Cindy; Allaire, Saralynn
2016-01-01
Systemic sclerosis (SSc) is an auto-immune connective tissue disease characterized by fibrosis of skin, blood vessels, and internal organs that results in significant disability. To identify the work barriers faced by people with systemic sclerosis (SSc) in maintaining employment. Thirty-six people with SSc who were working more than 8 hours per week completed the Work Experience Survey, which contains lists of potential work barriers, including the ability to travel to and from work; get around at work; perform essential job functions, including physical, cognitive, and task-related activities; work with others; and manage work conditions. Thirty-three participants completed and returned the questionnaires, most of whom were female, and working full time and in professional careers. Principal disease symptoms included fatigue, Raynaud's phenomenon, esophageal involvement, and leg or hand/wrist pain. All participants reported some barriers with a mean of 18 barriers per participant. At least three quarters of participants cited outside temperature (82%), cold temperatures inside the workplace (76%), and household work (76%), as barriers. The next most common barriers were using both hands (64%), arranging and taking part in social activities (64%), being able to provide self-care (61%) and working 8 hours (58%). Participants reported a wide range of barriers, from cold temperatures, to physical job, fatigue related, and non-workplace demands, in maintaining the worker role. The barriers reflect the disease symptoms they reported. Identifying workplace barriers facilitates the creation of job accommodations or adaptations that will allow people with SSc to continue working.
Task driven optimal leg trajectories in insect-scale legged microrobots
NASA Astrophysics Data System (ADS)
Doshi, Neel; Goldberg, Benjamin; Jayaram, Kaushik; Wood, Robert
Origami inspired layered manufacturing techniques and 3D-printing have enabled the development of highly articulated legged robots at the insect-scale, including the 1.43g Harvard Ambulatory MicroRobot (HAMR). Research on these platforms has expanded its focus from manufacturing aspects to include design optimization and control for application-driven tasks. Consequently, the choice of gait selection, body morphology, leg trajectory, foot design, etc. have become areas of active research. HAMR has two controlled degrees-of-freedom per leg, making it an ideal candidate for exploring leg trajectory. We will discuss our work towards optimizing HAMR's leg trajectories for two different tasks: climbing using electroadhesives and level ground running (5-10 BL/s). These tasks demonstrate the ability of single platform to adapt to vastly different locomotive scenarios: quasi-static climbing with controlled ground contact, and dynamic running with un-controlled ground contact. We will utilize trajectory optimization methods informed by existing models and experimental studies to determine leg trajectories for each task. We also plan to discuss how task specifications and choice of objective function have contributed to the shape of these optimal leg trajectories.
Why do flamingos stand on one leg?
Anderson, Matthew J; Williams, Sarah A
2010-01-01
A series of observational studies of captive Caribbean flamingos Phoenicopterus ruber were conducted to determine why flamingos rest on one leg. While frequently asked by the general public, this basic question has remained unanswered by the scientific community. Here we suggest that the latency of flamingos to initiate forward locomotion following resting on one leg is significantly longer than following resting on two, discounting the possibility that unipedal resting reduces muscle fatigue or enhances predatory escape. Additionally, we demonstrate that flamingos do not display lateral preferences at the individual or group levels when resting on one leg, with each bird dividing its resting time across both legs. We show that while flamingos prefer resting on one leg to two regardless of location, the percentage of birds resting on one leg is significantly higher among birds standing in the water than among those on land. Finally, we demonstrate a negative relationship between temperature and the percentage of observed birds resting on one leg, such that resting on one leg decreases as temperature rises. Results strongly suggest that unipedal resting aids flamingos in thermoregulation. (c) 2009 Wiley-Liss, Inc.
Dynamically Stable Legged Locomotion.
1983-01-27
sweeps the leg during stance, and the third places the foot during flight and controls body attitude during stance. Each of the three methods elucidates...secondary strategy has been to examine systems with springy legs, so that the role of resonant oscillatory leg behavior might be better understood. ’ The ...body attitude : I lopping _leit: ’ The control system rcgulate:; hopping height by manlil)Lulating hopping energy. The leg is springy, so hopping is a
Natural Occurrence of Aldol Condensation Products in Valencia Orange Oil.
Abreu, Ingo; Da Costa, Neil C; van Es, Alfred; Kim, Jung-A; Parasar, Uma; Poulsen, Mauricio L
2017-12-01
Cold pressed orange oils contain predominantly d-limonene (approximately 95%) and various other lower concentration monoterpenes, sesquiterpenes, sinensals plus 3 key aliphatic aldehydes: hexanal, octanal. and decanal. The aldol self-condensation products or "dimers" for each aldehyde have been postulated as being present at low concentrations in the oil. However, to date only the hexanal dimer has been previously reported. In this paper, cold pressed Valencia orange oil was fractionally distilled/folded and analyzed by GC and high resolution GC-MS to detect these compounds on 2 different capillary column phases. Subsequently the hexanal, octanal, and decanal self-aldol condensation products, 2-butyl-2-octenal, 2-hexyl-2-decenal, and 2-octyl-2-dodecenal, respectively, were detected in the folded oil. These predominantly trans configuration isomeric compounds were synthesized, to confirm them as being present in nature and evaluated organoleptically by a panel of evaluators. To further confirm the mechanism of their formation, the enriched oil was made into a simple beverage to show the effect on the formation of these aldol compounds under acidic conditions. Finally aliphatic aldehydes from hexanal to undecanal were reacted together in various combinatorial pairs to give an additional 33 self and mixed aldol condensation products, some of which were also detected in the folded oil. This paper discloses the structural elucidation and synthesis of 8 novel aldol condensation products found at trace concentrations in citrus and leading to a further 31 mass spectrally determined aldol products. Sensory evaluations and application of some of these components were demonstrated in a model citrus beverage. © 2017 Institute of Food Technologists®.
Cold Spray Aluminum–Alumina Cermet Coatings: Effect of Alumina Content
NASA Astrophysics Data System (ADS)
Fernandez, Ruben; Jodoin, Bertrand
2018-04-01
Deposition behavior and deposition efficiency were investigated for several aluminum-alumina mixture compositions sprayed by cold spray. An increase in deposition efficiency was observed. Three theories postulated in the literature, explaining this increase in deposition efficiency, were investigated and assessed. Through finite element analysis, the interaction between a ceramic particle peening an impacting aluminum particle was found to be a possible mechanism to increase the deposition efficiency of the aluminum particle, but a probability analysis demonstrated that this peening event is too unlikely to contribute to the increment in deposition efficiency observed. The presence of asperities at the substrate and deposited layers was confirmed by a single-layer deposition efficiency measurement and proved to be a major mechanism in the increment of deposition efficiency of the studied mixtures. Finally, oxide removal produced by the impact of ceramic particles on substrate and deposited layers was evaluated as the complement of the other effects and found to also play a major role in increasing the deposition efficiency. It was found that the coatings retained approximately half of the feedstock powder alumina content. Hardness tests have shown a steady increase with the coating alumina content. Dry wear tests have revealed no improvement in wear resistance in samples with an alumina content lower than 22 wt.% compared to pure aluminum coatings. Adhesion strength showed a steady improvement with increasing alumina content in the feedstock powder from 18.5 MPa for pure aluminum coatings to values above 70 MPa for the ones sprayed with the highest feedstock powder alumina content.
Leg stiffness and stride frequency in human running.
Farley, C T; González, O
1996-02-01
When humans and other mammals run, the body's complex system of muscle, tendon and ligament springs behaves like a single linear spring ('leg spring'). A simple spring-mass model, consisting of a single linear leg spring and a mass equivalent to the animal's mass, has been shown to describe the mechanics of running remarkably well. Force platform measurements from running animals, including humans, have shown that the stiffness of the leg spring remains nearly the same at all speeds and that the spring-mass system is adjusted for higher speeds by increasing the angle swept by the leg spring. The goal of the present study is to determine the relative importance of changes to the leg spring stiffness and the angle swept by the leg spring when humans alter their stride frequency at a given running speed. Human subjects ran on treadmill-mounted force platform at 2.5ms-1 while using a range of stride frequencies from 26% below to 36% above the preferred stride frequency. Force platform measurements revealed that the stiffness of the leg spring increased by 2.3-fold from 7.0 to 16.3 kNm-1 between the lowest and highest stride frequencies. The angle swept by the leg spring decreased at higher stride frequencies, partially offsetting the effect of the increased leg spring stiffness on the mechanical behavior of the spring-mass system. We conclude that the most important adjustment to the body's spring system to accommodate higher stride frequencies is that leg spring becomes stiffer.
Loading and performance of the support leg in kicking.
Ball, Kevin
2013-09-01
The punt kick is important in many football codes and support leg kinematics and ground reaction forces have been implicated in injury and performance in kicking. To evaluate ground reaction forces and support leg kinematics in the punt kick. Cross sectional study. Seven elite Australian football players performed maximal kicks into a net using both the preferred and non-preferred legs. A force plate measured ground reaction forces and an optical motion capture system (200Hz) collected kinematic data during the stance phase of the kick. Preferred and non-preferred legs were compared and performance was evaluated by correlating parameters with foot speed at ball contact. Vertical forces were larger than running at a similar speed but did not reach levels that might be considered an injury risk. Braking forces were directed solely posteriorly, as for soccer kicks, but lateral force patterns varied with some players experiencing greater forces medially and others laterally. A more extended support leg, larger peak vertical and braking force during the stance phase and a shorter stance contact time was associated with larger kick leg foot speed at ball contact. No difference existed between the preferred and non-preferred legs for ground reaction forces or support leg mechanics. To punt kick longer, a straighter support leg, less time on the ground and stronger braking should be encouraged. Conditioning the support leg to provide stronger braking potential is recommended. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Characterizing rapid-onset vasodilation to single muscle contractions in the human leg
Credeur, Daniel P.; Holwerda, Seth W.; Restaino, Robert M.; King, Phillip M.; Crutcher, Kiera L.; Laughlin, M. Harold; Padilla, Jaume
2014-01-01
Rapid-onset vasodilation (ROV) following single muscle contractions has been examined in the forearm of humans, but has not yet been characterized in the leg. Given known vascular differences between the arm and leg, we sought to characterize ROV following single muscle contractions in the leg. Sixteen healthy men performed random ordered single contractions at 5, 10, 20, 40, and 60% of their maximum voluntary contraction (MVC) using isometric knee extension made with the leg above and below heart level, and these were compared with single isometric contractions of the forearm (handgrip). Single thigh cuff compressions (300 mmHg) were utilized to estimate the mechanical contribution to leg ROV. Continuous blood flow was determined by duplex-Doppler ultrasound and blood pressure via finger photoplethysmography (Finometer). Single isometric knee extensor contractions produced intensity-dependent increases in peak leg vascular conductance that were significantly greater than the forearm in both the above- and below-heart level positions (e.g., above heart level: leg 20% MVC, +138 ± 28% vs. arm 20% MVC, +89 ± 17%; P < 0.05). Thigh cuff compressions also produced a significant hyperemic response, but these were brief and smaller in magnitude compared with single isometric contractions in the leg. Collectively, these data demonstrate the presence of a rapid and robust vasodilation to single muscle contractions in the leg that is largely independent of mechanical factors, thus establishing the leg as a viable model to study ROV in humans. PMID:25539935
Hanten, W P; Chandler, S D
1994-09-01
Experimental evidence does not currently exist to support the claims of clinical effectiveness for myofascial release techniques. This presents an obvious need to document the effects of myofascial release. The purpose of this study was to compare the effects of two techniques, sagittal plane isometric contract-relax and myofascial release leg pull for increasing hip flexion range of motion (ROM) as measured by the angle of passive straight-leg raise. Seventy-five nondisabled, female subjects 18-29 years of age were randomly assigned to contract-relax, leg pull, or control groups. Pretest hip flexion ROM was measured for each subject's right hip with a passive straight-leg raise test using a fluid-filled goniometer. Subjects in the treatment groups received either contract-relax or leg pull treatment applied to the right lower extremity; subjects in the control group remained supine quietly for 5 minutes. Following treatment, posttest straight-leg raise measurements were performed. A one-way analysis of variance followed by a Newman-Keuls post hoc comparison of mean gain scores showed that subjects receiving contract-relax treatment increased their ROM significantly more than those who received leg pull treatment, and the increase in ROM of subjects in both treatment groups was significantly higher than those of the control group. The results suggest that while both contract-relax and leg pull techniques can significantly increase hip flexion ROM in normal subjects, contract-relax treatment may be more effective and efficient than leg pull treatment.
Fraser, Rachel Z; Shitut, Mithila; Agrawal, Puja; Mendes, Odete; Klapholz, Sue
The leghemoglobin protein (LegH) from soy ( Glycine max) expressed in Pichia pastoris (LegH preparation, LegH Prep) imparts a meat-like flavor profile onto plant-based food products. The safety of LegH Prep was evaluated through a series of in vitro and in vivo tests. The genotoxic potential of LegH Prep was assessed using the bacterial reverse mutation assay (Ames test) and the in vitro chromosome aberration test. LegH Prep was nonmutagenic and nonclastogenic in each test, respectively. Systemic toxicity was assessed in a 28-day dietary study in male and female Sprague Dawley rats. There were no mortalities associated with the administration of LegH Prep. There were no clinical observations, body weight, ophthalmological, clinical pathology, or histopathological changes attributable to LegH Prep administration. There were no observed effects on male reproduction in this study, but the suggestion of a potential estrous cycle distribution effect in female rats prompted a second comprehensive 28-day dietary study in female Sprague Dawley rats. This study demonstrated that female reproductive parameters were comparable between rats treated with LegH Prep and concurrent control rats. These studies establish a no observed adverse effect level of 750 mg/kg/d LegH, which is over 100 times greater than the 90th percentile estimated daily intake. Collectively, the results of the studies presented raise no issues of toxicological concern with regard to LegH Prep under the conditions tested.
Aminiaghdam, Soran; Rode, Christian; Müller, Roy; Blickhan, Reinhard
2017-02-01
Pronograde trunk orientation in small birds causes prominent intra-limb asymmetries in the leg function. As yet, it is not clear whether these asymmetries induced by the trunk reflect general constraints on the leg function regardless of the specific leg architecture or size of the species. To address this, we instructed 12 human volunteers to walk at a self-selected velocity with four postures: regular erect, or with 30 deg, 50 deg and maximal trunk flexion. In addition, we simulated the axial leg force (along the line connecting hip and centre of pressure) using two simple models: spring and damper in series, and parallel spring and damper. As trunk flexion increases, lower limb joints become more flexed during stance. Similar to birds, the associated posterior shift of the hip relative to the centre of mass leads to a shorter leg at toe-off than at touchdown, and to a flatter angle of attack and a steeper leg angle at toe-off. Furthermore, walking with maximal trunk flexion induces right-skewed vertical and horizontal ground reaction force profiles comparable to those in birds. Interestingly, the spring and damper in series model provides a superior prediction of the axial leg force across trunk-flexed gaits compared with the parallel spring and damper model; in regular erect gait, the damper does not substantially improve the reproduction of the human axial leg force. In conclusion, mimicking the pronograde locomotion of birds by bending the trunk forward in humans causes a leg function similar to that of birds despite the different morphology of the segmented legs. © 2017. Published by The Company of Biologists Ltd.
Birn-Jeffery, Aleksandra V; Hubicki, Christian M; Blum, Yvonne; Renjewski, Daniel; Hurst, Jonathan W; Daley, Monica A
2014-11-01
Cursorial ground birds are paragons of bipedal running that span a 500-fold mass range from quail to ostrich. Here we investigate the task-level control priorities of cursorial birds by analysing how they negotiate single-step obstacles that create a conflict between body stability (attenuating deviations in body motion) and consistent leg force-length dynamics (for economy and leg safety). We also test the hypothesis that control priorities shift between body stability and leg safety with increasing body size, reflecting use of active control to overcome size-related challenges. Weight-support demands lead to a shift towards straighter legs and stiffer steady gait with increasing body size, but it remains unknown whether non-steady locomotor priorities diverge with size. We found that all measured species used a consistent obstacle negotiation strategy, involving unsteady body dynamics to minimise fluctuations in leg posture and loading across multiple steps, not directly prioritising body stability. Peak leg forces remained remarkably consistent across obstacle terrain, within 0.35 body weights of level running for obstacle heights from 0.1 to 0.5 times leg length. All species used similar stance leg actuation patterns, involving asymmetric force-length trajectories and posture-dependent actuation to add or remove energy depending on landing conditions. We present a simple stance leg model that explains key features of avian bipedal locomotion, and suggests economy as a key priority on both level and uneven terrain. We suggest that running ground birds target the closely coupled priorities of economy and leg safety as the direct imperatives of control, with adequate stability achieved through appropriately tuned intrinsic dynamics. © 2014. Published by The Company of Biologists Ltd.
H:q ratios and bilateral leg strength in college field and court sports players.
Cheung, Roy T H; Smith, Andrew W; Wong, Del P
2012-06-01
One of the key components in sports injury prevention is the identification of imbalances in leg muscle strength. However, different leg muscle characteristics may occur in large playing area (field) sports and small playing area (court) sports, which should be considered in regular injury prevention assessment. This study examined the isokinetic hamstrings-to-quadriceps (H:Q) ratio and bilateral leg strength balance in 40 male college (age: 23.4 ± 2.5 yrs) team sport players (field sport = 23, soccer players; court sport = 17, volleyball and basketball players). Five repetitions of maximal knee concentric flexion and concentric extension were performed on an isokinetic dynamometer at two speeds (slow: 60°·s(-1) and fast: 300°·s(-1)) with 3 minutes rest between tests. Both legs were measured in counterbalanced order with the dominant leg being determined as the leg used to kick a ball. The highest concentric peak torque values (Nm) of the hamstrings and quadriceps of each leg were analyzed after body mass normalization (Nm·kg(-1)). Court sport players showed significantly weaker dominant leg hamstrings muscles at both contraction speeds (P < 0.05). The H:Q ratio was significantly larger in field players in their dominant leg at 60°·s(-1) (P < 0.001), and their non-dominant leg at 300°·s(-1) (P < 0.001) respectively. Sport-specific leg muscle strength was evident in college players from field and court sports. These results suggest the need for different muscle strength training and rehabilitation protocols for college players according to the musculature requirements in their respective sports.
Waxman, Justin P; Schmitz, Randy J; Shultz, Sandra J
2015-10-01
Hamstring stiffness (K(HAM)) and leg stiffness (K(LEG)) are commonly examined relative to athletic performance and injury risk. Given these may be modifiable, it is important to understand day-to-day variations inherent in these measures before use in training studies. In addition, the extent to which K(HAM) and K(LEG) measure similar active stiffness characteristics has not been established. We investigated the interday measurement consistency of K(HAM) and K(LEG), and examined the extent to which K(LEG) predicted K(HAM) in 6 males and 9 females. K(HAM) was moderately consistent day-to-day (ICC(2,5) = .71; SEM = 76.3 N·m(-1)), and 95% limits of agreement (95% LOA) revealed a systematic bias with considerable absolute measurement error (95% LOA = 89.6 ± 224.8 N·m(-1)). Day-to-day differences in procedural factors explained 59.4% of the variance in day-to-day differences in K(HAM). Bilateral and unilateral K(LEG) was more consistent (ICC(2,3) range = .87-.94; SEM range = 1.0-2.91 kN·m(-1)) with lower absolute error (95% LOA bilateral= -2.0 ± 10.3; left leg = -0.36 ± 3.82; right leg = -1.05 ± 3.61 kN·m(-1)). K(LEG) explained 44% of the variance in K(HAM) (P < .01). Findings suggest that procedural factors must be carefully controlled to yield consistent and precise K(HAM) measures. The ease and consistency of K(LEG), and moderate correlation with K(HAM), may steer clinicians toward K(LEG) when measuring lower-extremity stiffness for screening studies and monitoring the effectiveness of training interventions over time.
Sasada, Syusaku; Tazoe, Toshiki; Nakajima, Tsuyoshi; Futatsubashi, Genki; Ohtsuka, Hiroyuki; Suzuki, Shinya; Zehr, E Paul; Komiyama, Tomoyoshi
2016-04-01
Neural interactions between regulatory systems for rhythmic arm and leg movements are an intriguing issue in locomotor neuroscience. Amplitudes of early latency cutaneous reflexes (ELCRs) in stationary arm muscles are modulated during rhythmic leg or arm cycling but not during limb positioning or voluntary contraction. This suggests that interneurons mediating ELCRs to arm muscles integrate outputs from neural systems controlling rhythmic limb movements. Alternatively, outputs could be integrated at the motoneuron and/or supraspinal levels. We examined whether a separate effect on the ELCR pathways and cortico-motoneuronal excitability during arm and leg cycling is integrated by neural elements common to the lumbo-sacral and cervical spinal cord. The subjects performed bilateral leg cycling (LEG), contralateral arm cycling (ARM), and simultaneous contralateral arm and bilateral leg cycling (A&L), while ELCRs in the wrist flexor and shoulder flexor muscles were evoked by superficial radial (SR) nerve stimulation. ELCR amplitudes were facilitated by cycling tasks and were larger during A&L than during ARM and LEG. A low stimulus intensity during ARM or LEG generated a larger ELCR during A&L than the sum of ELCRs during ARM and LEG. We confirmed this nonlinear increase in single motor unit firing probability following SR nerve stimulation during A&L. Furthermore, motor-evoked potentials following transcranial magnetic and electrical stimulation did not show nonlinear potentiation during A&L. These findings suggest the existence of a common neural element of the ELCR reflex pathway that is active only during rhythmic arm and leg movement and receives convergent input from contralateral arms and legs. Copyright © 2016 the American Physiological Society.
Increased Leg Bone Mineral Density and Content During the Initial Years of College Sport.
Scerpella, John J; Buehring, Bjoern; Hetzel, Scott J; Heiderscheit, Bryan C
2018-04-01
Scerpella, JJ, Buehring, B, Hetzel, SJ, and Heiderscheit, BC. Increased leg bone mineral density and content during the initial years of college sport. J Strength Cond Res 32(4): 1123-1130, 2018-Bone mineral density (BMD) and bone mineral content (BMC) data are useful parameters for evaluating how training practices promote bone health. We used dual-energy X-ray absorptiometry (DXA) to longitudinally assess sport-specific growth in leg and total body BMD/BMC over the initial 2 years of collegiate training. Eighty-five Division 1 collegiate basketball, hockey, and soccer athletes (50 males and 35 females; age 19.0 [0.8] years) underwent annual DXA scans. Leg and total body BMD/BMC were compared within and across two 1-year intervals (periods 1 and 2) using repeated-measures analysis of variance, adjusting for age, sex, race, and sport. Leg BMD, leg BMC, and total body BMC all increased over period 1 (0.05 g·cm [p = 0.001], 0.07 kg [p = 0.002], and 0.19 kg [p < 0.001] respectively). Changes in period 2 compared with period 1 were smaller for leg BMD (p = 0.001), leg BMC (p < 0.001), leg fat mass (p = 0.028), and total BMC (p = 0.005). Leg lean mass increased more during period 2 than period 1 (p = 0.018). Sports participation was the only significant predictor of change in leg BMD. Significant increases in both leg BMD and BMC were demonstrated over both 2-year periods, with greater gains during period 1. These gains highlight the importance of attentive training procedures, capitalizing on attendant physical benefits of increased BMD/BMC. Additional research in young adults, evaluating bone mass acquisition, will optimize performance and decrease risk of bone stress injury among collegiate athletes.
Birn-Jeffery, Aleksandra V.; Hubicki, Christian M.; Blum, Yvonne; Renjewski, Daniel; Hurst, Jonathan W.; Daley, Monica A.
2014-01-01
Cursorial ground birds are paragons of bipedal running that span a 500-fold mass range from quail to ostrich. Here we investigate the task-level control priorities of cursorial birds by analysing how they negotiate single-step obstacles that create a conflict between body stability (attenuating deviations in body motion) and consistent leg force–length dynamics (for economy and leg safety). We also test the hypothesis that control priorities shift between body stability and leg safety with increasing body size, reflecting use of active control to overcome size-related challenges. Weight-support demands lead to a shift towards straighter legs and stiffer steady gait with increasing body size, but it remains unknown whether non-steady locomotor priorities diverge with size. We found that all measured species used a consistent obstacle negotiation strategy, involving unsteady body dynamics to minimise fluctuations in leg posture and loading across multiple steps, not directly prioritising body stability. Peak leg forces remained remarkably consistent across obstacle terrain, within 0.35 body weights of level running for obstacle heights from 0.1 to 0.5 times leg length. All species used similar stance leg actuation patterns, involving asymmetric force–length trajectories and posture-dependent actuation to add or remove energy depending on landing conditions. We present a simple stance leg model that explains key features of avian bipedal locomotion, and suggests economy as a key priority on both level and uneven terrain. We suggest that running ground birds target the closely coupled priorities of economy and leg safety as the direct imperatives of control, with adequate stability achieved through appropriately tuned intrinsic dynamics. PMID:25355848
Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren
2014-01-01
Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.
Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan
2017-04-01
Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, p<0.05), and better balance was associated with younger participants in their non-dominant leg (R 2 =0.28, p<0.05) and their dominant leg (R 2 =0.39, p<0.05), and a higher number of hours spent training for the non-dominant leg R 2 =0.37, p<0.05). The multiple single-leg hop-stabilisation test demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.
Blum, Yvonne; Vejdani, Hamid R; Birn-Jeffery, Aleksandra V; Hubicki, Christian M; Hurst, Jonathan W; Daley, Monica A
2014-01-01
To achieve robust and stable legged locomotion in uneven terrain, animals must effectively coordinate limb swing and stance phases, which involve distinct yet coupled dynamics. Recent theoretical studies have highlighted the critical influence of swing-leg trajectory on stability, disturbance rejection, leg loading and economy of walking and running. Yet, simulations suggest that not all these factors can be simultaneously optimized. A potential trade-off arises between the optimal swing-leg trajectory for disturbance rejection (to maintain steady gait) versus regulation of leg loading (for injury avoidance and economy). Here we investigate how running guinea fowl manage this potential trade-off by comparing experimental data to predictions of hypothesis-based simulations of running over a terrain drop perturbation. We use a simple model to predict swing-leg trajectory and running dynamics. In simulations, we generate optimized swing-leg trajectories based upon specific hypotheses for task-level control priorities. We optimized swing trajectories to achieve i) constant peak force, ii) constant axial impulse, or iii) perfect disturbance rejection (steady gait) in the stance following a terrain drop. We compare simulation predictions to experimental data on guinea fowl running over a visible step down. Swing and stance dynamics of running guinea fowl closely match simulations optimized to regulate leg loading (priorities i and ii), and do not match the simulations optimized for disturbance rejection (priority iii). The simulations reinforce previous findings that swing-leg trajectory targeting disturbance rejection demands large increases in stance leg force following a terrain drop. Guinea fowl negotiate a downward step using unsteady dynamics with forward acceleration, and recover to steady gait in subsequent steps. Our results suggest that guinea fowl use swing-leg trajectory consistent with priority for load regulation, and not for steadiness of gait. Swing-leg trajectory optimized for load regulation may facilitate economy and injury avoidance in uneven terrain.
Blum, Yvonne; Vejdani, Hamid R.; Birn-Jeffery, Aleksandra V.; Hubicki, Christian M.; Hurst, Jonathan W.; Daley, Monica A.
2014-01-01
To achieve robust and stable legged locomotion in uneven terrain, animals must effectively coordinate limb swing and stance phases, which involve distinct yet coupled dynamics. Recent theoretical studies have highlighted the critical influence of swing-leg trajectory on stability, disturbance rejection, leg loading and economy of walking and running. Yet, simulations suggest that not all these factors can be simultaneously optimized. A potential trade-off arises between the optimal swing-leg trajectory for disturbance rejection (to maintain steady gait) versus regulation of leg loading (for injury avoidance and economy). Here we investigate how running guinea fowl manage this potential trade-off by comparing experimental data to predictions of hypothesis-based simulations of running over a terrain drop perturbation. We use a simple model to predict swing-leg trajectory and running dynamics. In simulations, we generate optimized swing-leg trajectories based upon specific hypotheses for task-level control priorities. We optimized swing trajectories to achieve i) constant peak force, ii) constant axial impulse, or iii) perfect disturbance rejection (steady gait) in the stance following a terrain drop. We compare simulation predictions to experimental data on guinea fowl running over a visible step down. Swing and stance dynamics of running guinea fowl closely match simulations optimized to regulate leg loading (priorities i and ii), and do not match the simulations optimized for disturbance rejection (priority iii). The simulations reinforce previous findings that swing-leg trajectory targeting disturbance rejection demands large increases in stance leg force following a terrain drop. Guinea fowl negotiate a downward step using unsteady dynamics with forward acceleration, and recover to steady gait in subsequent steps. Our results suggest that guinea fowl use swing-leg trajectory consistent with priority for load regulation, and not for steadiness of gait. Swing-leg trajectory optimized for load regulation may facilitate economy and injury avoidance in uneven terrain. PMID:24979750
Evaluation of arm-leg coordination in flat breaststroke.
Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M
2004-10-01
This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.
Proprioceptive influence on the optokinetic nystagmus.
Botti, F; Anastasopoulos, D; Kostadima, V; Bambagioni, D; Pettorossi, V E
2001-01-01
The influence of neck and leg proprioceptive inputs on optokinetic-induced quick phases was studied in humans. Ten subjects received unidirectional horizontal optokinetic stimulation (10-20%/s) during sinusoidal neck, leg and combined neck + leg proprioceptive stimulation. The optokinetic reflex was measured by electro-oculography. Neck stimulation induced a shift in the nystagmus beating field in the opposite direction to body movement (gain 0.3 0.4, phase 140-180 degrees). The beating field shift resulted totally from the amplitude and frequency modulation of optokinetic quick phases, as slow phases were not affected. Leg proprioceptive stimulation induced a similar effect, but the phase of the response lagged by approximately 90 degrees compared with that of neck response. With combined neck + leg stimulation, the amplitude of the effect was a sum of the separate effects, but the phase coincided with that of the leg response. This suggests that neck and leg proprioceptive signals do not add linearly and that the leg signal determines the time of the response.
Compliant leg behaviour explains basic dynamics of walking and running
Geyer, Hartmut; Seyfarth, Andre; Blickhan, Reinhard
2006-01-01
The basic mechanics of human locomotion are associated with vaulting over stiff legs in walking and rebounding on compliant legs in running. However, while rebounding legs well explain the stance dynamics of running, stiff legs cannot reproduce that of walking. With a simple bipedal spring–mass model, we show that not stiff but compliant legs are essential to obtain the basic walking mechanics; incorporating the double support as an essential part of the walking motion, the model reproduces the characteristic stance dynamics that result in the observed small vertical oscillation of the body and the observed out-of-phase changes in forward kinetic and gravitational potential energies. Exploring the parameter space of this model, we further show that it not only combines the basic dynamics of walking and running in one mechanical system, but also reveals these gaits to be just two out of the many solutions to legged locomotion offered by compliant leg behaviour and accessed by energy or speed. PMID:17015312
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... the ``Regulatory Guides'' collection of the NRC's Library at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2011-0152] Evaluations of Explosions Postulated To Occur at..., ``Evaluations of Explosions Postulated to Occur at Nearby Facilities and on Transportation Routes Near Nuclear...
Volume measurement of the leg with the depth camera for quantitative evaluation of edema
NASA Astrophysics Data System (ADS)
Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi
2017-02-01
Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.
Maginnis, Tara L
2006-07-22
Major morphological structures are sometimes produced not once, but twice. For example, stick insects routinely shed legs to escape a predator or tangled moult, and these legs are subsequently re-grown. Here, I show that in Sipyloidea sipylus, re-growth of a leg during development causes adults to have disproportionately smaller wings and increases wing loading. These morphological consequences of leg regeneration led to significant reductions in several biologically relevant measures of individual flight performance. This previously unrecognized tradeoff between legs and wings reveals the integrated nature of phasmid phenotypes, and I propose how this tradeoff may have shaped phasmid evolution.
NASA Astrophysics Data System (ADS)
Andrada, Emanuel; Müller, Roy; Blickhan, Reinhard
2016-11-01
As an alternative to walking and running, humans are able to skip. However, adult humans avoid it. This fact seems to be related to the higher energetic costs associated with skipping. Still, children, some birds, lemurs and lizards use skipping gaits during daily locomotion. We combined experimental data on humans with numerical simulations to test whether stability and robustness motivate this choice. Parameters for modelling were obtained from 10 male subjects. They locomoted using unilateral skipping along a 12 m runway. We used a bipedal spring loaded inverted pendulum to model and to describe the dynamics of skipping. The subjects displayed higher peak ground reaction forces and leg stiffness in the first landing leg (trailing leg) compared to the second landing leg (leading leg). In numerical simulations, we found that skipping is stable across an amazing speed range from skipping on the spot to fast running speeds. Higher leg stiffness in the trailing leg permits longer strides at same system energy. However, this strategy is at the same time less robust to sudden drop perturbations than skipping with a stiffer leading leg. A slightly higher stiffness in the leading leg is most robust, but might be costlier.
Neuromuscular Activation During Short-Track Speed Skating in Young Athletes.
Felser, Sabine; Behrens, Martin; Fischer, Susanne; Baeumler, Mario; Salomon, Ralf; Bruhn, Sven
2016-10-01
To investigate differences in muscle activation of both legs between the straight and the curve and changes in muscle activity during a 1000-m time trial (TT) and their relationship to the change in skating velocity in 9 young short-track speed skaters. The authors recorded skating times and EMG data from different leg muscles during maximum-effort skating trials on the straight and in the curve, as well as during a 1000-m TT. Muscle activation differs between the straight and the curves and between legs; ie, average activities of selected muscles of the right leg were significantly higher during skating through the curves than in the straights. This could not be observed for the left leg. The reduction in speed during the 1000-m TT highly correlates with the decrease in the muscle activity of both the tibialis anterior and the rectus femoris of the right leg. Muscle recruitment is different in relation to lap section (straight vs curve) and leg (right vs left leg). The decreased muscle activity of the tibialis anterior and rectus femoris of the right leg showed the highest relationships with the reduction in skating speed during the 1000-m TT.
Pipe crawler with stabilizing midsection
Zollinger, W.T.; Treanor, R.C.
1994-12-27
A pipe crawler is described having a midsection that provides the stability and flexibility to allow the pipe crawler to negotiate curved and uneven segments of piping while traveling through piping systems. The pipe crawler comprises a front leg assembly, a rear leg assembly, a midsection with a gimbal at each end for connecting the midsection to the front and rear leg assemblies in a flexible manner, and an air cylinder for changing the distance between the front and rear leg assemblies. The pipe crawler moves in ''inch worm'' fashion with the front and rear leg assemblies alternating between an extended and a retracted position as the air cylinder moves the retracted leg assembly forward. The midsection has a plurality of legs extending radially for holding the midsection within a maximum displacement from the piping axis so that the gimbals are not pivoted to extreme angles where they might lock up or seize. When the midsection is displaced sufficiently, its legs with wheels on each end engage the interior surface of the piping and prevent further displacement. Using two gimbals divides the angle between the planes defined by the front and rear leg assemblies which also helps to prevent excessive gimbal pivoting. 5 figures.
Pipe crawler with stabilizing midsection
Zollinger, William T.; Treanor, Richard C.
1994-01-01
A pipe crawler having a midsection that provides the stability and flexibty to allow the pipe crawler to negotiate curved and uneven segments of piping while traveling through piping systems. The pipe crawler comprises a front leg assembly, a rear leg assembly, a midsection with a gimbal at each end for connecting the midsection to the front and rear leg assemblies in a flexible manner, and an air cylinder for changing the distance between the front and rear leg assemblies. The pipe crawler moves in "inch worm" fashion with the front and rear leg assemblies alternating between an extended and a retracted position as the air cylinder moves the retracted leg assembly forward. The midsection has a plurality of legs extending radially for holding the midsection within a maximum displacement from the piping axis so that the gimbals are not pivoted to extreme angles where they might lock up or seize. When the midsection is displaced sufficiently, its legs with wheels on each end engage the interior surface of the piping and prevent further displacement. Using two gimbals divides the angle between the planes defined by the front and rear leg assemblies which also helps to prevent excessive gimbal pivoting.
Pipe crawler with stabilizing midsection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zollinger, W.T.; Treanor, R.C.
1993-09-20
This invention is comprised of a pipe crawler having a midsection that provides the stability and flexibility to allow the pipe crawler to negotiate curved and uneven segments of piping while traveling through piping systems. The pipe crawler comprises a front leg assembly, a rear leg assembly, a midsection with a gimbal at each end for connecting the midsection to the front and rear leg assemblies in a flexible manner, and an air cylinder for changing the distance between the front and rear leg assemblies. The pipe crawler moves in ``inch worm`` fashion with the front and rear leg assembliesmore » alternating between an extended and a retracted position as the air cylinder moves the retracted leg assembly forward. The midsection has a plurality of legs extending radially for holding the midsection within a maximum displacement from the piping axis so that the gimbals are not pivoted to extreme angles where they might lock up or seize. When the midsection is displaced sufficiently, its legs with wheels on each end engage the interior surface of the piping and prevent further displacement. Using two gimbals divides the angle between the planes defined by the front and rear leg assemblies which also helps to prevent excessive gimbal pivoting.« less
Pipe crawler with stabilizing midsection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zollinger, W.T.; Treanor, R.C.
1994-12-27
A pipe crawler is described having a midsection that provides the stability and flexibility to allow the pipe crawler to negotiate curved and uneven segments of piping while traveling through piping systems. The pipe crawler comprises a front leg assembly, a rear leg assembly, a midsection with a gimbal at each end for connecting the midsection to the front and rear leg assemblies in a flexible manner, and an air cylinder for changing the distance between the front and rear leg assemblies. The pipe crawler moves in ''inch worm'' fashion with the front and rear leg assemblies alternating between anmore » extended and a retracted position as the air cylinder moves the retracted leg assembly forward. The midsection has a plurality of legs extending radially for holding the midsection within a maximum displacement from the piping axis so that the gimbals are not pivoted to extreme angles where they might lock up or seize. When the midsection is displaced sufficiently, its legs with wheels on each end engage the interior surface of the piping and prevent further displacement. Using two gimbals divides the angle between the planes defined by the front and rear leg assemblies which also helps to prevent excessive gimbal pivoting. 5 figures.« less
Zult, Tjerk; Gokeler, Alli; van Raay, Jos J A M; Brouwer, Reinoud W; Zijdewind, Inge; Hortobágyi, Tibor
2017-01-01
The function of the anterior cruciate ligament (ACL) patients' non-injured leg is relevant in light of the high incidence of secondary ACL injuries on the contralateral side. However, the non-injured leg's function has only been examined for a selected number of neuromuscular outcomes and often without appropriate control groups. We measured a broad array of neuromuscular functions between legs of ACL patients and compared outcomes to age, sex, and physical activity matched controls. Thirty-two ACL-deficient patients (208 ± 145 days post-injury) and active and less-active controls (N = 20 each) participated in the study. We measured single- and multi-joint neuromuscular function in both legs in each group and expressed the overall neuromuscular function in each leg by calculating a mean z-score across all neuromuscular measures. A group by leg MANOVA and ANOVA were performed to examine group and leg differences for the selected outcomes. After an ACL injury, duration (-4.3 h/week) and level (Tegner activity score of -3.9) of sports activity decreased and was comparable to less-active controls. ACL patients showed bilateral impairments in the star excursion balance test compared to both control groups (P ≤ 0.004) and for central activation ratio compared to active controls (P ≤ 0.002). There were between-leg differences within each group for maximal quadriceps and hamstring strength, voluntary quadriceps activation, star excursion balance test performance, and single-leg hop distance (all P < 0.05), but there were no significant differences in quadriceps force accuracy and variability, knee joint proprioception, and static balance. Overall neuromuscular function (mean z-score) did not differ between groups, but ACL patients' non-injured leg displayed better neuromuscular function than the injured leg (P < 0.05). Except for poorer dynamic balance and reduced quadriceps activation, ACL patients had no bilateral neuromuscular deficits despite reductions in physical activity after injury. Therapists can use the non-injured leg as a reference to assess the injured leg's function for tasks measured in the present study, excluding dynamic balance and quadriceps activation. Rehabilitation after an ACL injury should be mainly focused on the injured leg. III.
Restless legs syndrome mimicking S1 radiculopathy.
Zambelis, Th; Wolgamuth, B R; Papoutsi, S N; Economou, N T
2016-01-01
Α case of a chronic idiopathic form of a severe type of Restless Legs Syndrome (RLS), which developed during pregnancy and persisted after this, misdiagnosed for 34 years as radiculopathy S1, is reported. In spite of the thorough clinical and laboratory investigation, in addition to constant changes of the therapeutic approach, the diagnosis of S1 radiculopathy could not be confirmed, resulting in a chronic clinical course; the latter was characterized by relapses and remissions not attributed or linked in any way to the treatment (various types of). In fact, it was due to a routine workup in a sleep clinic, where the patient was referred because of a coincident chronic insomnia (Restless Legs Syndrome is a known and important cause of insomnia/chronic insomnia), which resulted in a proper diagnosis and treatment of this case. With the use of Restless Legs Syndrome appropriate treatment (Pramipexole 0.18 mg taken at bedtime, a dopaminergic agent and Level A recommended drug for Restless Legs Syndrome) an excellent response and immediate elimination of symptoms was achieved. Restless Legs Syndrome may present with a variety of symptoms (with the most prominent shortly being reported with the acronym URGE: Urge to move the legs usually associated with unpleasant leg sensations, Rest induces symptoms, Getting active brings relief, Evening and night deteriorate symptoms); given the fact that Restless Legs Syndrome presents with a great variety and heterogeneity of symptoms (mostly pain, dysesthesia and paresthesia), which may occur in several other diseases (the so called "RLS mimics"), proper diagnosis of Restless Legs Syndrome usually fails. Restless Legs Syndrome misinterpreted as S1 radiculopathy, to the best of our knowledge, has not been reported yet in the literature. Here, case history, clinical course and common RLS mimics are presented. Different forms of Restless Legs Syndrome manifestations, which are commonly -as in this case- misinterpreted due to their mimicking several pathological conditions, Restless Legs Syndrome prevalence on general population according to various large epidemiological studies and pathogenic hypotheses on the issue of Restless Legs Syndrome are discussed. Finally, by presenting another possible "RLS-mimic" our aim is to highlight the common misdiagnosis of Restless Legs Syndrome, which can mimic a variety of disorders, some of which are very common, such as an S1 radiculopathy, thus raising concern among doctors of various specialties addressed to by Restless Legs Syndrome sufferers, on the importance of proper diagnosis of the syndrome.
Multisystemic Sarcoidosis Presenting as Pretibial Leg Ulcers.
Wollina, Uwe; Baunacke, Anja; Hansel, Gesina
2016-09-01
Sarcoidosis is a multisystemic disease of unknown etiology. Up to 30% of patients develop cutaneous manifestations, either specific or nonspecific. Ulcerating sarcoidosis leading to leg ulcers is a rare observation that may lead to confusions with other, more common types of chronic leg ulcers. We report the case of a 45-year-old female patient with chronic multisystemic sarcoidosis presenting with pretibial leg ulcers. Other etiology could be excluded. Histology revealed nonspecific findings. Therefore, the diagnosis of nonspecific leg ulcers in sarcoidosis was confirmed. Treatment consisted of oral prednisolone and good ulcer care. Complete healing was achieved within 6 months. Sarcoidosis is a rare cause of leg ulcers and usually sarcoid granulomas can be found. Our patient illustrates that even in the absence of sarcoid granulomas, leg ulcers can be due to sarcoidosis. © The Author(s) 2016.
Marra, John Joseph; Wessell, Brian J.; Liang, George
2013-03-05
A sealing apparatus in a gas turbine. The sealing apparatus includes a seal housing apparatus coupled to a disc/rotor assembly so as to be rotatable therewith during operation of the gas turbine. The seal housing apparatus comprises a base member, a first leg portion, a second leg portion, and spanning structure. The base member extends generally axially between forward and aft rows of rotatable blades and is positioned adjacent to a row of stationary vanes. The first leg portion extends radially inwardly from the base member and is coupled to the disc/rotor assembly. The second leg portion is axially spaced from the first leg portion, extends radially inwardly from the base member, and is coupled to the disc/rotor assembly. The spanning structure extends between and is rigidly coupled to each of the base member, the first leg portion, and the second leg portion.
Coolman, B R; Marretta, S M; Kakoma, I; Wallig, M A; Coolman, S L; Paul, A J
1998-12-01
The purpose of this study was to determine the effects of a one-minute chlorhexidine gluconate skin preparation protocol prior to cephalic vein catheterization. Twenty-three healthy beagle dogs had one leg aseptically prepared and the opposite leg served as a control. Twenty-six- and 77-hour time groups were studied. Chlorhexidine-treated legs had significantly lower cutaneous bacterial counts than the control legs prior to catheter insertion and prior to catheter withdrawal for both time groups. Control legs developed significantly more dermatitis than the treated legs after 77 h. A one-minute preparation with 4% chlorhexidine gluconate was an effective method for sustained reduction of cutaneous bacterial counts at peripheral intravenous catheter insertion points in dogs. Increased cutaneous bacterial counts were associated with significantly more microscopic dermatitis in untreated legs after 77 h of catheterization.
Prpic, Nikola-Michael; Janssen, Ralf; Wigand, Barbara; Klingler, Martin; Damen, Wim G M
2003-12-01
Leg development in Drosophila has been studied in much detail. However, Drosophila limbs form in the larva as imaginal discs and not during embryogenesis as in most other arthropods. Here, we analyze appendage genes in the spider Cupiennius salei and the beetle Tribolium castaneum. Differences in decapentaplegic (dpp) expression suggest a different mode of distal morphogen signaling suitable for the specific geometry of growing limb buds. Also, expression of the proximal genes homothorax (hth) and extradenticle (exd) is significantly altered: in the spider, exd is restricted to the proximal leg and hth expression extends distally, while in insects, exd is expressed in the entire leg and hth is restricted to proximal parts. This reversal of spatial specificity demonstrates an evolutionary shift, which is nevertheless compatible with a conserved role of this gene pair as instructor of proximal fate. Different expression dynamics of dachshund and Distal-less point to modifications in the regulation of the leg gap gene system. We comment on the significance of this finding for attempts to homologize leg segments in different arthropod classes. Comparison of the expression profiles of H15 and optomotor-blind to the Drosophila patterns suggests modifications also in the dorsal-ventral patterning system of the legs. Together, our results suggest alterations in many components of the leg developmental system, namely proximal-distal and dorsal-ventral patterning, and leg segmentation. Thus, the leg developmental system exhibits a propensity to evolutionary change, which probably forms the basis for the impressive diversity of arthropod leg morphologies.
Protection against high intravascular pressure in giraffe legs.
Petersen, Karin K; Hørlyck, Arne; Ostergaard, Kristine H; Andresen, Joergen; Broegger, Torbjoern; Skovgaard, Nini; Telinius, Niklas; Laher, Ismael; Bertelsen, Mads F; Grøndahl, Carsten; Smerup, Morten; Secher, Niels H; Brøndum, Emil; Hasenkam, John M; Wang, Tobias; Baandrup, Ulrik; Aalkjaer, Christian
2013-11-01
The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along the artery. Histology of the isolated median artery confirmed dense sympathetic innervation at the narrowing. Structure and contractility of small arteries from muscular beds in the leg and neck were compared. The arteries from the legs demonstrated an increased media thickness-to-lumen diameter ratio, increased media volume, and increased numbers of smooth muscle cells per segment length and furthermore, they contracted more strongly than arteries from the neck (500 ± 49 vs. 318 ± 43 mmHg; n = 6 legs and neck, respectively). Finally, the transient increase in interstitial fluid pressure following injection of saline was 5.5 ± 1.7 times larger (n = 8) in the leg than in the neck. We conclude that 1) tissue compliance in the legs is low; 2) large arteries of the legs function as resistance arteries; and 3) structural adaptation of small muscle arteries allows them to develop an extraordinary tension. All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure.
Three-dimensional knee joint contact forces during walking in unilateral transtibial amputees.
Silverman, Anne K; Neptune, Richard R
2014-08-22
Individuals with unilateral transtibial amputations have greater prevalence of osteoarthritis in the intact knee joint relative to the residual leg and non-amputees, but the cause of this greater prevalence is unclear. The purpose of this study was to compare knee joint contact forces and the muscles contributing to these forces between amputees and non-amputees during walking using forward dynamics simulations. We predicted that the intact knee contact forces would be higher than those of the residual leg and non-amputees. In the axial and mediolateral directions, the intact and non-amputee legs had greater peak tibio-femoral contact forces and impulses relative to the residual leg. The peak axial contact force was greater in the intact leg relative to the non-amputee leg, but the stance phase impulse was greater in the non-amputee leg. The vasti and hamstrings muscles in early stance and gastrocnemius in late stance were the largest contributors to the joint contact forces in the non-amputee and intact legs. Through dynamic coupling, the soleus and gluteus medius also had large contributions, even though they do not span the knee joint. In the residual leg, the prosthesis had large contributions to the joint forces, similar to the soleus in the intact and non-amputee legs. These results identify the muscles that contribute to knee joint contact forces during transtibial amputee walking and suggest that the peak knee contact forces may be more important than the knee contact impulses in explaining the high prevalence of intact leg osteoarthritis. Copyright © 2014 Elsevier Ltd. All rights reserved.
Choi, Kyuju; Bak, Jongwoo; Cho, Minkwon; Chung, Yijung
2016-09-01
[Purpose] This study investigated the changes in the muscle activities of the trunk and lower limbs of healthy adults during a one-legged bridge exercise using a sling, and with the addition of hip abduction. [Subjects and Methods] Twenty-seven healthy individuals participated in this study (14 males and 13 females). The participants were instructed to perform the bridge exercises under five different conditions. Trunk and lower limb muscle activation of the erector spinae (ES), external oblique (EO), gluteus maximus (GM), and biceps femoris (BF) was measured using surface electromyography. Data analysis was performed using the mean scores of three trials performed under each condition. [Results] There was a significant increase in bilateral EO and contralateral GM with the one-legged bridge compared with the one-legged bridge with sling exercise. Muscle activation of the ipsilateral GM and BF was significantly less during the one-legged bridge exercise compared to the one-legged bridge with sling exercise, and was significantly greater during the one-legged bridge with hip abduction compared to the one-legged bridge exercise. The muscle activation of the contralateral GM and BF was significantly greater with the one-legged bridge with hip abduction compared to the general bridge exercise. [Conclusion] With the one-legged bridge with hip abduction, the ipsilateral EO, GM and BF muscle activities were significantly greater than those of the one-legged bridge exercise. The muscle activation of all trunk and contralateral lower extremity muscles increased with the bridge with sling exercises compared with general bridge exercises.
HDice, Highly-Polarized Low-Background Frozen-Spin HD Targets for CLAS experiments at Jefferson Lab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Xiangdong; Bass, Christopher; D'Angelo, Annalisa
2012-12-01
Large, portable frozen-spin HD (Deuterium-Hydride) targets have been developed for studying nucleon spin properties with low backgrounds. Protons and Deuterons in HD are polarized at low temperatures (~10mK) inside a vertical dilution refrigerator (Oxford Kelvinox-1000) containing a high magnetic field (up to 17T). The targets reach a frozen-spin state within a few months, after which they can be cold transferred to an In-Beam Cryostat (IBC). The IBC, a thin-walled dilution refrigerator operating either horizontally or vertically, is use with quasi-4{pi} detector systems in open geometries with minimal energy loss for exiting reaction products in nucleon structure experiments. The first applicationmore » of this advanced target system has been used for Spin Sum Rule experiments at the LEGS facility in Brookhaven National Laboratory. An improved target production and handling system has been developed at Jefferson Lab for experiments with the CEBAF Large Acceptance Spectrometer, CLAS.« less
The identification of submerged skeletonized remains.
Byard, Roger W; Both, Katrin; Simpson, Ellie
2008-03-01
Examination was undertaken of skeletonized remains contained within 2 rubber boots dredged by a fishing boat from a depth of 145 m, approximately 185 km off the southern Australian coast in the Great Australian Bight. The boots had been manufactured in Australia in July 1993 and were of a type commonly used by local fishermen. Examination of the lower legs and feet revealed well-preserved bones with arthritic changes in keeping with an older male. DNA analyses using reference samples taken from relatives of fishermen who had disappeared in the area resulted in the identification of the victim as a 52-year-old prawn fisherman who had been swept off a boat over a decade earlier. DNA stability had been maintained by the low light, cold temperatures, and alkaline pH of the ocean floor. Integration of pathologic, anthropologic, and biologic analyses with police investigations enabled a positive identification to be made despite the unusual nature of the location of the remains and the time lapse since the disappearance of the victim.
Schreiber, R.B.; Fero, A.H.; Sejvar, J.
1997-12-16
The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel to form a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive valving also includes bistable vents at the upper end of the thermal insulating barrier for releasing steam. A removable, modular neutron shield extending around the upper end of the reactor cavity below the nozzles forms with the upwardly and outwardly tapered transition on the outer surface of the reactor vessel, a labyrinthine channel which reduces neutron streaming while providing a passage for the escape of steam during a severe accident, and for the cooling air which is circulated along the reactor cavity walls outside the thermal insulating barrier during normal operation of the reactor. 8 figs.
SIG Galileo final converter. Technical summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinderman, J.D.
1979-05-01
The report summarizes significant events, activities and achievements on the SIG/Galileo Converter Program at 3M Company during the period June 1, 1978 through May 15, 1979. A stop work order was received from DOE on January 29, 1979 and all subsequent work and close out activities targeted for completion by May 15, 1979. Section A describes, in detail, the component configurations developed and proposed for the SN-1 converter. This converter was the Flight Design with the possible exception of N-leg improvements and a cold frame-housing interface processing change. Included at the end of the converter description is the status ofmore » the design at the time of the stop work order. In Section B, the activities performed to accomplish the design goals are described as they occurred. Section C lists all pertinent documentation which was developed and issued relating to the design of the converter. This includes drawings, specifications, procedures and analysis. Operating requirements for the SN-1 converter are given.« less
Schreiber, Roger B.; Fero, Arnold H.; Sejvar, James
1997-01-01
The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel to form a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive valving also includes bistable vents at the upper end of the thermal insulating barrier for releasing steam. A removable, modular neutron shield extending around the upper end of the reactor cavity below the nozzles forms with the upwardly and outwardly tapered transition on the outer surface of the reactor vessel, a labyrinthine channel which reduces neutron streaming while providing a passage for the escape of steam during a severe accident, and for the cooling air which is circulated along the reactor cavity walls outside the thermal insulating barrier during normal operation of the reactor.
Rule-Based Motion Coordination for the Adaptive Suspension Vehicle on Ternary-Type Terrain
1990-12-01
robot-window-array* nil) (defvar *robot..window..width* nil) (defvar * rebot -.window..heig)ht* nil) (defvar *terrain-buffer* nil) (defvar *terrain...cond ((momrber leg lift-able-leg. -test #’equal) log) (t nil)) .(dafmethod (test-overlap- rebot ipltcable-leg) (log) (nond ((and (member leg place-able
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-25
... and Lower Leg Disability Benefits Questionnaire) Activity: Comment Request AGENCY: Veterans Benefits... ``OMB Control No. 2900-NEW (Knee and Lower Leg Conditions Disability Benefits Questionnaire)'' in any... INFORMATION: Title: Knee and Lower Leg Conditions Disability Benefits Questionnaire, VA Form 21-0960M-9. OMB...
Evaluation of a smartphone-based assessment system in subjects with chronic ankle instability.
Chiu, Ya-Lan; Tsai, Yi-Ju; Lin, Chueh-Ho; Hou, You-Ruei; Sung, Wen-Hsu
2017-02-01
Ankle sprain is the most common sports-related injury, and approximately 80% of patients studied suffered recurrent sprains. These repeated ankle injuries could cause chronic ankle instability, a decrease in sports performance, and a decrease in postural control ability. At the present time, smartphones have become very popular and powerful devices, and smartphone applications (apps) that have been shown to have good validity have been designed to measure human body motion. However, the app focusing on ankle function assessment and rehabilitation is still not widely used and has very limited functions. The purpose of this study is to evaluate the feasibility of smartphone-based systems in the assessment of postural control ability for patients with chronic ankle instability. Fifteen physically active adults (6 male, 9 female; aged = 23.4 ± 5.28 years; height = 167.13 ± 7.3 cm; weight = 62.06 ± 10.82 kg; BMI = 22.08 ± 2.57 kg/ m 2 ) were recruited, and these participants had at least one leg that was evaluated as scoring lower than 27 points according to the Cumberland Ankle Instability Tool (CAIT). The smartphone used in the study was ASUS Zenfone 2, and an app developed using MIT App Inventor was used to record built-in accelerometer data during the assessment process. Subjects were asked to perform single leg stance for 20 s in eyes-open and eyes-closed conditions with each leg. The smartphone was fixed in an upright position on the middle of the shin, using an exercise armband, with the screen facing forward. The average of recorded acceleration data was used to represent the postural control performance, and higher values indicated more instability. Data were analyzed with a paired t-test with SPSS 17.0, and the statistical significance was set as alpha <0.05. A significant difference was found between CAIT scores from the healthier leg and injured leg (healthier leg 23.07 ± 3.80 vs. injured leg 18.27 ± 3.92, p < 0.001). Significant differences were also found between the scores for the healthier leg and injured leg during both eyes-open and eyes-closed conditions (eyes-open: healthier leg 0.051 ± 0.018 vs. injured leg 0.072 ± 0.034, p = 0.027; eyes-closed: healthier leg 0.100 ± 0.031 vs. injured leg 0.123 ± 0.038, p = 0.001, unit: m/s 2 ). Significant differences were also found between eyes-open and eyes-closed conditions during both single leg standing with healthier leg and injured leg (healthier leg: eyes-open 0.051 ± 0.018 vs. eyes-closed 0.100 ± 0.031, p < 0.001; injured leg: eyes-open 0.072 ± 0.034 vs. eyes-closed 0.123 ± 0.038, p = 0.001, unit: m/s 2 ). The results demonstrate that the smartphone software can be used to discriminate between the different performances of the healthier leg and injured leg, and also between eyes-open and eyes-closed conditions. The smartphone may have the potential to be a convenient, easy-to-use, and feasible tool for the assessment of postural control ability on subjects with chronic ankle instability. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Abiko, Seiya
2005-01-01
Einstein, who had already developed the light-quantum theory, knew the inadequacy of Maxwell's theory in the microscopic sphere. Therefore, in writing his paper on special relativity, he had to set up the light-velocity postulate independently of the relativity postulate in order to make the electromagnetic foundation of physics compatible with…
A Theory of Vocational Development for Women.
ERIC Educational Resources Information Center
Zytowski, Donald G.
In postulate I, the modal life role for women is described as that of the homemaker. Postulate II proposes that the nature of the woman's role is not static, ultimately bearing no distinction from that of men. Postulate III states that the role of women is orderly and developmental, divisible into major segments according to the major task in…
Strengthening Sustainability and Resiliency of a Future Force, Phase 1. FY2010-2011 Summer Study
2011-03-01
Resiliency of a Future Force: Phase I Interim Report - 48 Please Enter Custom Water factor adjustments below: m Unit Level* (Gat/Ptisan/ Dti ...cost of mov- ing the consumables in terms of the assets required to move the commodity and the security Intra Theater Resupply: 4 Legs Army...Expeditionary Force-Logistics ResupplyDetails Legl Leg 2 Leg 3 Leg 4 Resupply Trip Legs Super FOB (Div)to Base Camp (bde) Base Camp (Bde) to FOB (Bn
Leporace, Gustavo; Batista, Luiz Alberto; Serra Cruz, Raphael; Zeitoune, Gabriel; Cavalin, Gabriel Armondi; Metsavaht, Leonardo
2018-03-01
The purpose of this study was to test the validity of dynamic leg length discrepancy (DLLD) during gait as a radiation-free screening method for measuring anatomic leg length discrepancy (ALLD). Thirty-three subjects with mild leg length discrepancy walked along a walkway and the dynamic leg length discrepancy (DLLD) was calculated using a motion analysis system. Pearson correlation and paired Student t -tests were applied to calculate the correlation and compare the differences between DLLD and ALLD (α = 0.05). The results of our study showed DLLD is not a valid method to predict ALLD in subjects with mild limb discrepancy.
Running in the real world: adjusting leg stiffness for different surfaces
NASA Technical Reports Server (NTRS)
Ferris, D. P.; Louie, M.; Farley, C. T.
1998-01-01
A running animal coordinates the actions of many muscles, tendons, and ligaments in its leg so that the overall leg behaves like a single mechanical spring during ground contact. Experimental observations have revealed that an animal's leg stiffness is independent of both speed and gravity level, suggesting that it is dictated by inherent musculoskeletal properties. However, if leg stiffness was invariant, the biomechanics of running (e.g. peak ground reaction force and ground contact time) would change when an animal encountered different surfaces in the natural world. We found that human runners adjust their leg stiffness to accommodate changes in surface stiffness, allowing them to maintain similar running mechanics on different surfaces. These results provide important insight into mechanics and control of animal locomotion and suggest that incorporating an adjustable leg stiffness in the design of hopping and running robots is important if they are to match the agility and speed of animals on varied terrain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Look, Nicole; Arellano, Christopher J.; Grabowski, Alena M.
2013-12-15
In this paper, we study dynamic stability during running, focusing on the effects of speed, and the use of a leg prosthesis. We compute and compare the maximal Lyapunov exponents of kinematic time-series data from subjects with and without unilateral transtibial amputations running at a wide range of speeds. We find that the dynamics of the affected leg with the running-specific prosthesis are less stable than the dynamics of the unaffected leg and also less stable than the biological legs of the non-amputee runners. Surprisingly, we find that the center-of-mass dynamics of runners with two intact biological legs are slightlymore » less stable than those of runners with amputations. Our results suggest that while leg asymmetries may be associated with instability, runners may compensate for this effect by increased control of their center-of-mass dynamics.« less
Kobara, Kenichi; Takahashi, Hisashi; Fujita, Daisuke; Osaka, Hiroshi; Ito, Tomotaka; Suehiro, Tadanobu; Watanabe, Susumu
2015-08-01
[Purpose] The purpose of this study was to investigate the effect of the timing of leg support elevation on the horizontal force acting on the buttocks in a reclining wheelchair. [Subjects and Methods] The participants were 17 healthy men. Two experimental conditions were tested: the leg-down and leg-up conditions. The back support was reclined at increasing angles, from the initial upright position (IUP), proceeding to the fully reclined position (FRP), and returned to the upright position (RUP). The posterior inclination phase was from IUP to FRP, and the returning inclination phase was from FRP to RUP. [Results] The horizontal force under the leg-up condition was significantly higher than that under the leg-down condition in all positions of back support. [Conclusion] The leg supports should be positioned downward before reclining the back support of a wheelchair.
33 CFR 147.817 - Sir Douglas Morpeth Tension Leg Platform safety zone.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sir Douglas Morpeth Tension Leg... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.817 Sir Douglas Morpeth Tension Leg Platform safety zone. (a) Description. The Sir Douglas Morpeth Tension Leg Platform (Morpeth...
A Comparison of Two Injection Locations in Obese Patients Having Lower Leg/Foot Surgery
2015-10-13
Strain of Muscle and/or Tendon of Lower Leg; Fracture of Lower Leg; Crushing Injury of Lower Leg; Fracture Malunion - Ankle and/ or Foot; Complete Tear, Ankle and/or Foot Ligament; Pathological Fracture - Ankle and/or Foot; Loose Body in Joint of Ankle and/or Foot
The effect of Brazilian Propolis on leg health in broilers reared under heat stress
USDA-ARS?s Scientific Manuscript database
Exposing broiler chickens to heat stress increases leg abnormalities and Gait Score, also it reduced the time of Latency to Lie Test. This experiment was conducted to examine the effect of dietary supplemention with green Brazilian propolis on Latency to Lie Test for leg strength and leg abnormaliti...
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Culler, V. H.; Merrbaum, S. (Inventor)
1981-01-01
Several parameters of a small region of a muscle tissue or other object, can be simultaneously measured using with minimal traumatizing or damage of the object, a trifunctional transducer which can determine the force applied by a muscle fiber, the displacement of the fiber, and the change in thickness of the fiber. The transducer has three legs with inner ends joined together and outer ends formed to piece the tissue and remain within it. Two of the legs are relatively stiff, to measure force applied by the tissue, and a third leg is relatively flexible to measure displacement of the tissue relative to one or both stiff legs, and with the three legs lying in a common plane so that the force and displacement measurements all relate to the same direction of muscle movements. A flexible loop is attached to one of the stiff legs to measure changes in muscle thickness, with the upper end of the loop fixed to the leg and the lower end of the loop bearing against the surface of the tissue and being free to slide on the leg.
Durgin, Frank H; Fox, Laura F; Hoon Kim, Dong
2003-11-01
We investigated the phenomenon of limb-specific locomotor adaptation in order to adjudicate between sensory-cue-conflict theory and motor-adaptation theory. The results were consistent with cue-conflict theory in demonstrating that two different leg-specific hopping aftereffects are modulated by the presence of conflicting estimates of self-motion from visual and nonvisual sources. Experiment 1 shows that leg-specific increases in forward drift during attempts to hop in place on one leg while blindfolded vary according to the relationship between visual information and motor activity during an adaptation to outdoor forward hopping. Experiment 2 shows that leg-specific changes in performance on a blindfolded hopping-to-target task are similarly modulated by the presence of cue conflict during adaptation to hopping on a treadmill. Experiment 3 shows that leg-specific aftereffects from hopping additionally produce inadvertent turning during running in place while blindfolded. The results of these experiments suggest that these leg-specific locomotor aftereffects are produced by sensory-cue conflict rather than simple motor adaptation.
Mizuno, Ju; Namba, Chikara; Takahashi, Toru
2014-10-01
We investigated external pressure on peroneal nerve tract coming in contact with two kinds of leg holders using pressure distribution measurement system BIG- MAT® (Nitta Corp., Osaka) in the lithotomy position Peak contact (active) pressure at the left fibular head region coming in contact with knee-crutch-type leg holder M® (Takara Belmont Corp., Osaka), which supports the left popliteal fossa, was 78.0 ± 26.4 mmHg. On the other hand, peak contact pressure at the left lateral lower leg region coming in contact with boot-support-type leg holder Bel Flex® (Takara Belmont Corp., Osaka), which supports the left lower leg and foot was 26.3±7.9 mmHg. These results suggest that use of knee-crutch-type leg holder is more likely to induce common peroneal nerve palsy at the fibular head region, but use of boot-support-type leg holder dose not easily induce superficial peroneal nerve palsy at the lateral lower leg region, because capillary blood pressure is known to be 32 mmHg. Safer holders for positioning will be developed to prevent nerve palsy based on the analysis of chronological change in external pressure using BIG-MAT® system during anesthesia.
Frantsevich, Leonid I; Cruse, Holk
2005-10-01
The turning movement of a bug, Mesocerus marginatus, is observed when it walks upside-down below a horizontal beam and, at the end of the beam, performs a sharp turn by 180 degrees . The turn at the end of the beam is accomplished in three to five steps, without strong temporal coordination among legs. During the stance, leg endpoints (tarsi) run through rounded trajectories, rotating to the same side in all legs. During certain phases of the turn, a leg is strongly depressed and the tarsus crosses the midline. Swing movements rotate to the same side as do leg endpoints in stance, in strong contrast to the typical swing movements found in turns or straight walk on a flat surface. Terminal location is found after the search through a trajectory that first moves away from the body and then loops back to find substrate. When a leg during stance has crossed the midline, in the following swing movement the leg may move even stronger on the contralateral side, i.e. is stronger depressed, in contrast to swing movements in normal walking, where the leg is elevated. These results suggest that the animals apply a different control strategy compared to walking and turning on a flat surface.
Relationships between maximal anaerobic power of the arms and legs and javelin performance.
Bouhlel, E; Chelly, M S; Tabka, Z; Shephard, R
2007-06-01
The aim of this study was to examine relationships between maximal anaerobic power, as measured by leg and arm force-velocity tests, estimates of local muscle volume and javelin performance. Ten trained national level male javelin throwers (mean age 19.6+/- 2 years) participated in this study. Maximal anaerobic power, maximal force and maximal velocity were measured during leg (Wmax-L) and arm (Wmax-A) force-velocity tests, performed on appropriately modified forms of Monark cycle ergometer. Estimates of leg and arm muscle volume were made using a standard anthropometric kit. Maximal force of the leg (Fmax-L) was significantly correlated with estimated leg muscle volume (r=0.71, P<0.05). Wmax-L and Wmax-A were both significantly correlated with javelin performance (r=0.76, P<0.01; r=0.71, P <0.05, respectively). Maximal velocity of the leg (Vmax-L) was also significantly correlated with throwing performance (r=0.83; P<0.001). Wmax of both legs and arms were significantly correlated with javelin performance, the closest correlation being for Wmax-L; this emphasizes the importance of the leg muscles in this sport. Fmax-L and Vmax-L were related to muscle volume and to javelin performance, respectively. Force-velocity testing may have value in regulating conditioning and rehabilitation in sports involving throwing.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
Watson, J T; Ritzmann, R E
1998-01-01
We have combined high-speed video motion analysis of leg movements with electromyogram (EMG) recordings from leg muscles in cockroaches running on a treadmill. The mesothoracic (T2) and metathoracic (T3) legs have different kinematics. While in each leg the coxa-femur (CF) joint moves in unison with the femurtibia (FT) joint, the relative joint excursions differ between T2 and T3 legs. In T3 legs, the two joints move through approximately the same excursion. In T2 legs, the FT joint moves through a narrower range of angles than the CF joint. In spite of these differences in motion, no differences between the T2 and T3 legs were seen in timing or qualitative patterns of depressor coxa and extensor tibia activity. The average firing frequencies of slow depressor coxa (Ds) and slow extensor tibia (SETi) motor neurons are directly proportional to the average angular velocity of their joints during stance. The average Ds and SETi firing frequency appears to be modulated on a cycle-by-cycle basis to control running speed and orientation. In contrast, while the frequency variations within Ds and SETi bursts were consistent across cycles, the variations within each burst did not parallel variations in the velocity of the relevant joints.
Bennett, Terry L.; Kraft, Shannon M.; Reaves, Barbara J.; Mima, Joji; O’Brien, Kevin M.; Starai, Vincent J.
2013-01-01
During infection, the intracellular pathogenic bacterium Legionella pneumophila causes an extensive remodeling of host membrane trafficking pathways, both in the construction of a replication-competent vacuole comprised of ER-derived vesicles and plasma membrane components, and in the inhibition of normal phagosome:endosome/lysosome fusion pathways. Here, we identify the LegC3 secreted effector protein from L. pneumophila as able to inhibit a SNARE- and Rab GTPase-dependent membrane fusion pathway in vitro, the homotypic fusion of yeast vacuoles (lysosomes). This vacuole fusion inhibition appeared to be specific, as similar secreted coiled-coiled domain containing proteins from L. pneumophila, LegC7/YlfA and LegC2/YlfB, did not inhibit vacuole fusion. The LegC3-mediated fusion inhibition was reversible by a yeast cytosolic extract, as well as by a purified soluble SNARE, Vam7p. LegC3 blocked the formation of trans-SNARE complexes during vacuole fusion, although we did not detect a direct interaction of LegC3 with the vacuolar SNARE protein complexes required for fusion. Additionally, LegC3 was incapable of inhibiting a defined synthetic model of vacuolar SNARE-driven membrane fusion, further suggesting that LegC3 does not directly inhibit the activity of vacuolar SNAREs, HOPS complex, or Sec17p/18p during membrane fusion. LegC3 is likely utilized by Legionella to modulate eukaryotic membrane fusion events during pathogenesis. PMID:23437241
Vahtrik, Doris; Gapeyeva, Helena; Ereline, Jaan; Pääsuke, Mati
2014-01-01
The aim of the present study was to evaluate an isometric maximal voluntary contraction (MVC) force of the leg extensor muscles and its relationship with knee joint loading during gait prior and after total knee arthroplasty (TKA). Custom-made dynamometer was used to assess an isometric MVC force of the leg extensor muscles and 3-D motion analysis system was used to evaluate the knee joint loading during gait in 13 female patients (aged 49-68 years) with knee osteoarthritis. Patients were evaluated one day before, and three and six months following TKA in the operated and non-operated leg. Six months after TKA, MVC force of the leg extensor muscles for the operated leg did not differ significantly as compared to the preoperative level, whereas it remained significantly lower for the non-operated leg and controls. The knee flexion moment and the knee joint power during mid stance of gait was improved six months after TKA, remaining significantly lowered compared with controls. Negative moderate correlation between leg extensor muscles strength and knee joint loading for the operated leg during mid stance was noted three months after TKA. The correlation analysis indicates that due to weak leg extensor muscles, an excessive load is applied to knee joint during mid stance of gait in patients, whereas in healthy subjects stronger knee-surrounding muscles provide stronger knee joint loading during gait. III (correlational study). Copyright © 2013 Elsevier B.V. All rights reserved.
Hamada, Yoshimasa; Bando, Tetsuya; Nakamura, Taro; Ishimaru, Yoshiyasu; Mito, Taro; Noji, Sumihare; Tomioka, Kenji; Ohuchi, Hideyo
2015-09-01
Hemimetabolous insects such as the cricket Gryllus bimaculatus regenerate lost tissue parts using blastemal cells, a population of dedifferentiated proliferating cells. The expression of several factors that control epigenetic modification is upregulated in the blastema compared with differentiated tissue, suggesting that epigenetic changes in gene expression might control the differentiation status of blastema cells during regeneration. To clarify the molecular basis of epigenetic regulation during regeneration, we focused on the function of the Gryllus Enhancer of zeste [Gb'E(z)] and Ubiquitously transcribed tetratricopeptide repeat gene on the X chromosome (Gb'Utx) homologues, which regulate methylation and demethylation of histone H3 lysine 27 (H3K27), respectively. Methylated histone H3K27 in the regenerating leg was diminished by Gb'E(z)(RNAi) and was increased by Gb'Utx(RNAi). Regenerated Gb'E(z)(RNAi) cricket legs exhibited extra leg segment formation between the tibia and tarsus, and regenerated Gb'Utx(RNAi) cricket legs showed leg joint formation defects in the tarsus. In the Gb'E(z)(RNAi) regenerating leg, the Gb'dac expression domain expanded in the tarsus. By contrast, in the Gb'Utx(RNAi) regenerating leg, Gb'Egfr expression in the middle of the tarsus was diminished. These results suggest that regulation of the histone H3K27 methylation state is involved in the repatterning process during leg regeneration among cricket species via the epigenetic regulation of leg patterning gene expression. © 2015. Published by The Company of Biologists Ltd.
Schindlbeck, Katharina A; Becker, Janek; Berger, Felix; Mehl, Arne; Rewitzer, Charlotte; Geffe, Sarah; Koch, Peter M; Preiß, Jan C; Siegmund, Britta; Maul, Jochen; Marzinzik, Frank
2017-01-01
Inflammatory bowel disease has been associated with neurological symptoms including restless legs syndrome. Here, we investigated the impact of restless legs syndrome in patients with inflammatory bowel disease on sleep, fatigue, mood, cognition, and quality of life. Two groups of inflammatory bowel disease patients, with and without restless legs syndrome, were prospectively evaluated for sleep disorders, fatigue, daytime sleepiness, depression, anxiety, and health-related quality of life. Furthermore, global cognitive function, executive function, attention, and concentration were assessed in both groups. Disease activity and duration of inflammatory bowel disease as well as current medication were assessed by interview. Inflammatory bowel disease patients with and without restless legs syndrome were matched for age, education, severity, and duration of their inflammatory bowel disease. Patients with inflammatory bowel disease and clinically relevant restless leg syndrome suffered significantly more frequent from sleep disturbances including sleep latency and duration, more fatigue, and worse health-related quality of life as compared to inflammatory bowel disease patients without restless legs syndrome. Affect and cognitive function including cognitive flexibility, attention, and concentration showed no significant differences among groups, indicating to be not related to restless legs syndrome. Sleep disorders including longer sleep latency, shorter sleep duration, and fatigue are characteristic symptoms of restless legs syndrome in inflammatory bowel disease patients, resulting in worse health-related quality of life. Therefore, clinicians treating patients with inflammatory bowel disease should be alert for restless legs syndrome.
Calf restoration with asymmetric fat injection in polio sequelae.
Yazar, Memet; Kurt Yazar, Sevgi; Kozanoğlu, Erol
2016-09-01
Many things cause leg asymmetry and sequelae seen after poliomyelitis infections are still a cause of leg deformities. In this study, lipofilling and liposuction combinations are performed on patients with poliomyelitis sequelae. Volume deficiency is not the only leg problem with polio sequelae, leg length is also a problem. For this reason, the length deficiency must be addressed in order to achieve the desired symmetry. The aim of this study is correcting limb asymmetry by a method addressing both limb length deficiency by heel raise and volume deficiency by injection of fat based on corrected limb length. From 2011 through 2013, 10 female patients who had unilateral leg atrophy as a result of paediatric polio infections were included in our study. All of the patients were treated with liposuction and lipofilling combinations. During planning, a ridge was placed under the affected leg in order to equalize the lengths of both legs. The fat injection sites on the affected leg were marked to mimic the unaffected leg. All the patients stated that they were satisfied with the results. Transient hypoesthesia was seen in only one patient, but this was spontaneously resolved six months later. The study results indicate that the asymmetric fat injection procedure can be a good technique to use with patients who have polio sequelae, both with short legs and volume deformities. 4. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Hébert-Losier, Kim; Schelin, Lina; Tengman, Eva; Strong, Andrew; Häger, Charlotte K
2018-03-01
Anterior cruciate ligament (ACL) ruptures may lead to knee dysfunctions later in life. Single-leg tasks are often evaluated, but bilateral movements may also be compromised. Our aim was to use curve analyses to examine double-leg drop-jump kinematics in ACL-reconstructed, ACL-deficient, and healthy-knee cohorts. Subjects with unilateral ACL ruptures treated more than two decades ago (17-28years) conservatively with physiotherapy (ACL PT , n=26) or in combination with reconstructive surgery (ACL R , n=28) and healthy-knee controls (n=25) performed 40-cm drop-jumps. Three-dimensional knee, hip, and trunk kinematics were analyzed during Rebound, Flight, and Landing phases. Curves were time-normalized and compared between groups (injured and non-injured legs of ACL PT and ACL R vs. non-dominant and dominant legs of controls) and within groups (between legs) using functional analysis of variance methods. Compared to controls, ACL groups exhibited less knee and hip flexion on both legs during Rebound and greater knee external rotation on their injured leg at the start of Rebound and Landing. ACL R also showed less trunk flexion during Rebound. Between-leg differences were observed in ACL R only, with the injured leg more internally rotated at the hip. Overall, kinematic curves were similar between ACL R and ACL PT . However, compared to controls, deviations spanned a greater proportion of the drop-jump movement at the hip in ACL R and at the knee in ACL PT . Trunk and bilateral leg kinematics during double-leg drop-jumps are still compromised long after ACL-rupture care, independent of treatment. Curve analyses indicate the presence of distinct compensatory mechanisms in ACL PT and ACL R compared to controls. Copyright © 2018 Elsevier B.V. All rights reserved.
Macdonald, Ben; O'Neill, John; Pollock, Noel; Van Hooren, Bas
2018-03-06
Poor hamstring strength-endurance is a risk factor for hamstring injuries. This study investigated the effectiveness of the single-leg Roman hold and Nordic hamstring curl in improving hamstring strength-endurance. Twelve Gaelic footballers (mean ± standard deviation age, height and mass were 25.17 ± 3.46 years, 179.25 ± 5.88 cm, 85.75 ± 4.75 kilo) with a history of hamstring injury were randomized into 2 groups that performed 6 weeks of either Nordic hamstring curl, or single-leg Roman chair hold training. The single-leg hamstring bridge (SLHB) was measured pre- and post- intervention. The Roman chair group showed a very likely moderate magnitude improvement on SLHB performance for both legs (23.7% for the previously injured leg [90% confidence interval 9.6% to 39.6%] and 16.9% for the non-injured leg [6.2% to 28.8%]). The Nordic curl group showed a likely trivial change in SLHB performance for the non-injured leg (-2.1% [-6.7% to 2.6%]) and an unclear, but possibly trivial change for the previously injured leg (0.3% [-5.6% to 6.6%]). The Roman chair group improved very likely more with a moderate magnitude in both the non-injured (19.5% [8.0% to 32.2%]) and the previously injured leg (23.3% [8.5% to 40.0%]) compared to the Nordic curl group. This study demonstrated that 6-weeks single-leg Roman chair training substantially improved SLHB performance, suggesting that it may be an efficacious strategy to mitigate hamstring (re-) injury risk. Conversely, 6-weeks Nordic curl training did not substantially improve SLHB performance, suggesting this may not be the intervention of choice for modifying this risk factor.
Profiling Isokinetic Strength by Leg Preference and Position in Rugby Union Athletes.
Brown, Scott R; Brughelli, Matt; Bridgeman, Lee A
2016-05-01
Muscle imbalances aid in the identification of athletes at risk for lower-extremity injury. Little is known regarding the influence that leg preference or playing position may have on lower-extremity muscle strength and asymmetry. To investigate lower-extremity strength profiles in rugby union athletes and compare isokinetic knee- and hip-strength variables between legs and positions. Thirty male academy rugby union athletes, separated into forwards (n = 15) and backs (n = 15), participated in this cross-sectional analysis. Isokinetic dynamometry was used to evaluate peak torque, angle of peak torque, and strength ratios of the preferred and nonpreferred legs during seated knee extension/flexion and supine hip extension/flexion at 60°/s. Backs were older (ES = 1.6) but smaller in stature (ES = -0.47) and body mass (ES = -1.3) than the forwards. The nonpreferred leg was weaker than the preferred leg for forwards during extension (ES = -0.37) and flexion (ES = -0.21) actions and for backs during extension (ES = -0.28) actions. Backs were weaker at the knee than forwards in the preferred leg during extension (ES = -0.50) and flexion (ES = -0.66) actions. No differences were observed in strength ratios between legs or positions. Backs produced peak torque at longer muscle lengths in both legs at the knee (ES = -0.93 to -0.94) and hip (ES = -0.84 to -1.17) than the forwards. In this sample of male academy rugby union athletes, the preferred leg and forwards displayed superior strength compared with the nonpreferred leg and backs. These findings highlight the importance of individualized athletic assessments to detect crucial strength differences in male rugby union athletes.
Bean, Jonathan F; Kiely, Dan K; LaRose, Sharon; Leveille, Suzanne G
2008-12-01
To test which rehabilitative impairments are associated with higher mobility performance among community-dwelling, mobility-limited older adults. Cross-sectional analysis of baseline data from participants within a randomized controlled trial. Outpatient rehabilitation research center. Community-dwelling older adults (N=138; mean age, 75.4 y) with mobility limitations as defined by the Short Physical Performance Battery (SPPB). Not applicable. Balance measured via the Berg Balance Scale, leg strength, leg velocity, submaximal aerobic capacity, body mass index (BMI), and mobility performance as measured by the SPPB. Each of the 5 physiologic attributes (unipedal balance, leg strength, leg velocity, submaximal aerobic capacity, BMI) was categorized into tertiles by using lower values as reference for impairment status. Within an adjusted model, measures associated with higher SPPB performance (>9) included a BBS score greater than or equal to 54 (odds ratio [OR]=4.54; 95% confidence interval [CI], 1.11-18.60), leg strength greater than or equal to 21.5 N/kg (OR=30.35; 95% CI, 5.48-168.09), leg velocity .0101 to .0129 m.s(-1).kg(-1) (OR=5.31; 95% CI, 1.25-22.57), and leg velocity greater than or equal to .0130 m.s(-1).kg(-1) (OR=22.86; 95% CI, 3.88-134.75). Our investigation highlights the importance of rehabilitative impairments in leg strength, leg velocity, and balance as being associated with mobility status as measured by the SPPB. In our sample of participants within an exercise trial, submaximal aerobic capacity and BMI status were not associated with mobility performance. These findings suggest that the augmentation of not only leg strength and balance but also leg velocity may be important in the rehabilitative care of mobility-limited older adults.
Leg ulceration as a long-term complication of deep vein thrombosis.
Walker, Natalie; Rodgers, Anthony; Birchall, Nicholas; Norton, Robyn; MacMahon, Stephen
2003-12-01
To evaluate the role of deep vein thrombosis as a cause of leg ulcers. A population-based, case-control study was conducted in Central and North Auckland, New Zealand. Cases comprised 241 people aged 40 to 99 years and on the electoral roll, with current leg ulcers (all types). Cases were identified by means of notification from health professionals and by self-referral. Controls were 224 people in the same age group, without leg ulcers, who were selected from the electoral roll by using a stratified random sampling process. The occurrence of leg ulceration as a consequence of exposure to deep vein thrombosis or being at high risk of deep vein thrombosis (that is, people with a family history of deep vein thrombosis, and/or a history of leg fracture and/or hip, leg, or foot surgery). After adjustment for age, sex, and other potential confounding factors, people who had a diagnosed thromboembolism were at almost three times higher risk of having a leg ulcer (odds ratio, 2.92; 95% confidence interval (CI), 1.47 to 6.08). In addition, people who had been at high risk of a venous thrombosis but were not diagnosed with this condition (eg, people with a history of major leg surgery) were also at increased risk of ulceration (odds ratio, 2.25; 95% CI, 1.49-3.42). Overall, 56% (95% CI, 33% - 71%) of leg ulcers were attributed to being at high risk of deep vein thrombosis. Deep vein thrombosis and factors that place people at high risk of deep vein thrombosis are an important cause of leg ulcers in older people. This finding strengthens the rationale for the routine and long-term use of thromboprophylaxis, particularly in high-risk patients.
Greenberg, Lina; Hatini, Victor
2009-06-01
The Drosophila leg imaginal disc provides a paradigm with which to understand the fundamental developmental mechanisms that generate an intricate appendage structure. Leg formation depends on the subdivision of the leg proximodistal (PD) axis into broad domains by the leg gap genes. The leg gap genes act combinatorially to initiate the expression of the Notch ligands Delta (Dl) and Serrate (Ser) in a segmental pattern. Dl and Ser induce the expression of a set of transcriptional regulators along the segment border, which mediate leg segment growth and joint morphogenesis. Here we show that Lines accumulates in nuclei in the presumptive tarsus and the inter-joints of proximal leg segments and governs the formation of these structures by destabilizing the nuclear protein Bowl. Across the presumptive tarsus, lines modulates the opposing expression landscapes of the leg gap gene dachshund (dac) and the tarsal PD genes, bric-a-brac 2 (bab), apterous (ap) and BarH1 (Bar). In this manner, lines inhibits proximal tarsal fates and promotes medial and distal tarsal fates. Across proximal leg segments, lines antagonizes bowl to promote Dl expression by relief-of-repression. In turn, Dl signals asymmetrically to stabilize Bowl in adjacent distal cells. Bowl, then, acts cell-autonomously, together with one or more redundant factors, to repress Dl expression. Together, lines and bowl act as a binary switch to generate a stable Notch signaling interface between Dl-expressing cells and adjacent distal cell. lines plays analogous roles in developing antennae, which are serially homologous to legs, suggesting evolutionarily conserved roles for lines in ventral appendage formation.
Obstacle avoidance locomotor tasks: adaptation, memory and skill transfer.
Kloter, Evelyne; Dietz, Volker
2012-05-01
The aim of this study was to explore the neural basis of adaptation, memory and skill transfer during human stepping over obstacles. Whilst walking on a treadmill, subjects had to perform uni- and bilateral obstacle steps. Acoustic feedback information about foot clearance was provided. Non-noxious electrical stimuli were applied to the right tibial nerve during the mid-stance phase of the right leg, i.e. 'prior' to the right or 'during' the left leg swing over the obstacle. The electromyogram (EMG) responses evoked by these stimuli in arm and leg muscles are known to reflect the neural coordination during normal and obstacle steps. The leading and trailing legs rapidly adapted foot clearance during obstacle steps with small further changes when the same obstacle condition was repeated. This adaptation was associated with a corresponding decrease in arm and leg muscle reflex EMG responses. Arm (but not leg) muscle EMG responses were greater when the stimulus was applied 'during' obstacle crossing by the left leg leading compared with stimulation 'prior' to right leg swing over the obstacle. A corresponding difference existed in arm muscle background EMG. The results indicate that, firstly, the somatosensory information gained by the performance and adaptation of uni- and bilateral obstacle stepping becomes transferred to the trailing leg in a context-specific manner. Secondly, EMG activity in arm and leg muscles parallels biomechanical adaptation of foot clearance. Thirdly, a consistently high EMG activity in the arm muscles during swing over the obstacle is required for equilibrium control. Thus, such a precision locomotor task is achieved by a context-specific, coordinated activation of arm and leg muscles for performance and equilibrium control that includes adaptation, memory and skill transfer. © 2012 The Authors. European Journal of Neuroscience © 2012 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.
Selionov, V A; Solopova, I A; Zhvansky, D S
2016-01-01
We studied the effect of arm movements and movements of separate arm joints on the electrophysiological and kinematic characteristics of voluntary and vibration-triggered stepping-like leg movements under the conditions of horizontal support of upper and lower limbs. The horizontal support of arms provided a significantly increase in the rate of activation of locomotor automatism by non-invasive impact on tonic sensory inputs. The addition of active arm movements during involuntary rhytmic stepping-like leg movements led to an increase in EMG activity of hip muscles and was accompanied by an increase in the amplitude of hip and shin movements. Passive arm movements had the same effect on induced leg movements. The movement of the shoulder joints led to an increase in the activity of hip muscles and an increase in the amplitude of movements of the knee and hip joints. At the same time, the movement of forearms. and wrists had similar facilitating effect on electrophysiological and kinematic characteristics of rhytmic stepping-like movements, but influenced the distal segments of legs to a greater extent. Under the conditions of sub-threshold vibration of leg muscles, voluntary arm movements led to the activation of involuntary rhytmic stepping movements. During voluntary leg movements, the addition of arm movements had a significantly smaller impact on the parameters of rhytmic stepping than during involuntary leg movements. Thus, the simultaneous movements of upper and lower limbs are an effective method of activation of neural networks connecting the rhythm generators of arms and legs. Under the conditions of arm and leg unloading, the interactions between the cervical and lumbosacral segments of the spinal cord seem to play the major role in the impact of arm movements on the patterns of leg movements. The described methods of activation of interlimb interactions can be used in the rehabilitation of post-stroke patients and patients with spinal cord injuries, Parkinson's disease and other neurological diseases.
Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan
2016-05-01
Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.
Bipedal distribution of human vestibular-evoked postural responses during asymmetrical standing
Marsden, J F; Castellote, J; Day, B L
2002-01-01
Galvanic vestibular stimulation (GVS) evokes responses in muscles of both legs when bilateral stimuli are applied during normal stance. We have used this technique to assess whether asymmetrical standing alters the distribution of responses in the two legs. Subjects stood either asymmetrically with 75 % of their body weight on one leg or symmetrically with each leg taking 50 % of their body weight. The net response in each leg was taken from changes in ground reaction force measured from separate force plates under each foot. The net force profile consisted of a small initial force change that peaked at ∼200 ms followed by an oppositely directed larger component that peaked at ∼450 ms. We analysed the second force component since it was responsible for the kinematic response of lateral body sway and tilt towards the anode. In the horizontal plane, both legs produced lateral force responses that were in the same direction but larger in the leg ipsilateral to the cathodal ear. There were also vertical force responses that were of equal size in both legs but acted in opposite directions. When subjects stood asymmetrically the directions of the force responses remained the same but their magnitudes changed. The lateral force response became 2-3 times larger for the more loaded leg and the vertical forces increased 1.5 times on average for both legs. Control experiments showed that these changes could not be explained by either the consistent (< 5 deg) head tilt towards the side of the loaded leg or the changes in background muscle activity associated with the asymmetrical posture. We conclude that the redistribution of force responses in the two legs arises from a load-sensing mechanism. We suggest there is a central interaction between load-related afferent input from the periphery and descending motor signals from balance centres. PMID:12096073
Zhou, R; Alvarado, L; Kim, S; Chong, S L; Mushahwar, V K
2017-10-01
The spinal cervico-lumbar interaction during rhythmic movements in humans has recently been studied; however, the role of arm movements in modulating the corticospinal drive to the legs is not well understood. The goals of this study were to investigate the effect of active rhythmic arm movements on the corticospinal drive to the legs ( study 1 ) and assess the effect of simultaneous arm and leg training on the corticospinal pathway after incomplete spinal cord injury (iSCI) ( study 2). In study 1 , neurologically intact (NI) participants or participants with iSCI performed combinations of stationary and rhythmic cycling of the arms and legs while motor evoked potentials (MEPs) were recorded from the vastus lateralis (VL) muscle. In the NI group, arm cycling alone could facilitate the VL MEP amplitude, suggesting that dynamic arm movements strongly modulate the corticospinal pathway to the legs. No significant difference in VL MEP between conditions was found in participants with iSCI. In study 2 , participants with iSCI underwent 12 wk of electrical stimulation-assisted cycling training: one group performed simultaneous arm and leg (A&L) cycling and the other legs-only cycling. MEPs in the tibialis anterior (TA) muscle were compared before and after training. After training, only the A&L group had a significantly larger TA MEP, suggesting increased excitability in the corticospinal pathway. The findings demonstrate the importance of arm movements in modulating the corticospinal drive to the legs and suggest that active engagement of the arms in lower limb rehabilitation may produce better neural regulation and restoration of function. NEW & NOTEWORTHY This study aimed to demonstrate the importance of arm movements in modulating the corticospinal drive to the legs. It provides direct evidence in humans that active movement of the arms could facilitate corticospinal transmission to the legs and, for the first time, shows that facilitation is absent after spinal cord injury. Active engagement of the arms in lower limb rehabilitation increased the excitability of the corticospinal pathway and may produce more effective improvement in leg function. Copyright © 2017 the American Physiological Society.
Steerable Hopping Six-Legged Robot
NASA Technical Reports Server (NTRS)
Younse, Paulo; Aghazarian, Hrand
2010-01-01
The figure depicts selected aspects of a six-legged robot that moves by hopping and that can be steered in the sense that it can be launched into a hop in a controllable direction. This is a prototype of hopping robots being developed for use in scientific exploration of rough terrain on remote planets that have surface gravitation less than that of Earth. Hopping robots could also be used on Earth, albeit at diminished hopping distances associated with the greater Earth gravitation. The upper end of each leg is connected through two universal joints to an upper and a lower hexagonal frame, such that the tilt of the leg depends on the relative position of the two frames. Two non-back-driveable worm-gear motor drives are used to control the relative position of the two frames along two axes 120 apart, thereby controlling the common tilt of all six legs and thereby, further, controlling the direction of hopping. Each leg includes an upper and a lower aluminum frame segment with a joint between them. A fiberglass spring, connected via hinges to both segments, is used to store hopping energy prior to launch into a hop and to cushion the landing at the end of the hop. A cable for loading the spring is run into each leg through the center of the universal joints and then down along the center lines of the segments to the lower end of the leg. A central spool actuated by a motor with a harmonic drive and an electromagnetic clutch winds in all six cables to compress all six springs (thereby also flexing all six legs) simultaneously. To ensure that all the legs push off and land in the same direction, timing- belt pulley drives are attached to the leg segments, restricting the flexing and extension of all six legs to a common linear motion. In preparation for a hop, the spool can be driven to load the spring legs by an amount corresponding to a desired hop distance within range. The amount of compression can be computed from the reading of a shaft-angle encoder that indicates the amount by which the spool has been turned. When the robot is ready to hop, the electromagnetic clutch disengages the motor from the spool, thus releasing the cable restraints on the springs and allowing the springs to extend all six legs simultaneously.
Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability
NASA Technical Reports Server (NTRS)
Sunada, Eric; Birur, Gajanana C.; Ganapathi, Gani B.; Miller, Jennifer; Berisford, Daniel; Stephan, Ryan
2010-01-01
NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.
Stanley, Jamie; Buchheit, Martin; Peake, Jonathan M
2012-03-01
We investigated the effect of hydrotherapy on time-trial performance and cardiac parasympathetic reactivation during recovery from intense training. On three occasions, 18 well-trained cyclists completed 60 min high-intensity cycling, followed 20 min later by one of three 10-min recovery interventions: passive rest (PAS), cold water immersion (CWI), or contrast water immersion (CWT). The cyclists then rested quietly for 160 min with R-R intervals and perceptions of recovery recorded every 30 min. Cardiac parasympathetic activity was evaluated using the natural logarithm of the square root of mean squared differences of successive R-R intervals (ln rMSSD). Finally, the cyclists completed a work-based cycling time trial. Effects were examined using magnitude-based inferences. Differences in time-trial performance between the three trials were trivial. Compared with PAS, general fatigue was very likely lower for CWI (difference [90% confidence limits; -12% (-18; -5)]) and CWT [-11% (-19; -2)]. Leg soreness was almost certainly lower following CWI [-22% (-30; -14)] and CWT [-27% (-37; -15)]. The change in mean ln rMSSD following the recovery interventions (ln rMSSD(Post-interv)) was almost certainly higher following CWI [16.0% (10.4; 23.2)] and very likely higher following CWT [12.5% (5.5; 20.0)] compared with PAS, and possibly higher following CWI [3.7% (-0.9; 8.4)] compared with CWT. The correlations between performance, ln rMSSD(Post-interv) and perceptions of recovery were unclear. A moderate correlation was observed between ln rMSSD(Post-interv) and leg soreness [r = -0.50 (-0.66; -0.29)]. Although the effects of CWI and CWT on performance were trivial, the beneficial effects on perceptions of recovery support the use of these recovery strategies.
Vigelsø, A; Gram, M; Dybboe, R; Kuhlman, A B; Prats, C; Greenhaff, P L; Constantin-Teodosiu, D; Birk, J B; Wojtaszewski, J F P; Dela, F; Helge, J W
2016-04-15
This study aimed to provide molecular insight into the differential effects of age and physical inactivity on the regulation of substrate metabolism during moderate-intensity exercise. Using the arteriovenous balance technique, we studied the effect of immobilization of one leg for 2 weeks on leg substrate utilization in young and older men during two-legged dynamic knee-extensor moderate-intensity exercise, as well as changes in key proteins in muscle metabolism before and after exercise. Age and immobilization did not affect relative carbohydrate and fat utilization during exercise, but the older men had higher uptake of exogenous fatty acids, whereas the young men relied more on endogenous fatty acids during exercise. Using a combined whole-leg and molecular approach, we provide evidence that both age and physical inactivity result in intramuscular lipid accumulation, but this occurs only in part through the same mechanisms. Age and inactivity have been associated with intramuscular triglyceride (IMTG) accumulation. Here, we attempt to disentangle these factors by studying the effect of 2 weeks of unilateral leg immobilization on substrate utilization across the legs during moderate-intensity exercise in young (n = 17; 23 ± 1 years old) and older men (n = 15; 68 ± 1 years old), while the contralateral leg served as the control. After immobilization, the participants performed two-legged isolated knee-extensor exercise at 20 ± 1 W (∼50% maximal work capacity) for 45 min with catheters inserted in the brachial artery and both femoral veins. Biopsy samples obtained from vastus lateralis muscles of both legs before and after exercise were used for analysis of substrates, protein content and enzyme activities. During exercise, leg substrate utilization (respiratory quotient) did not differ between groups or legs. Leg fatty acid uptake was greater in older than in young men, and although young men demonstrated net leg glycerol release during exercise, older men showed net glycerol uptake. At baseline, IMTG, muscle pyruvate dehydrogenase complex activity and the protein content of adipose triglyceride lipase, acetyl-CoA carboxylase 2 and AMP-activated protein kinase (AMPK)γ3 were higher in young than in older men. Furthermore, adipose triglyceride lipase, plasma membrane-associated fatty acid binding protein and AMPKγ3 subunit protein contents were lower and IMTG was higher in the immobilized than the contralateral leg in young and older men. Thus, immobilization and age did not affect substrate choice (respiratory quotient) during moderate exercise, but the whole-leg and molecular differences in fatty acid mobilization could explain the age- and immobilization-induced IMTG accumulation. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Gram, M.; Dybboe, R.; Kuhlman, A. B.; Prats, C.; Greenhaff, P. L.; Constantin‐Teodosiu, D.; Birk, J. B.; Wojtaszewski, J. F. P.; Dela, F.; Helge, J. W.
2016-01-01
Key points This study aimed to provide molecular insight into the differential effects of age and physical inactivity on the regulation of substrate metabolism during moderate‐intensity exercise.Using the arteriovenous balance technique, we studied the effect of immobilization of one leg for 2 weeks on leg substrate utilization in young and older men during two‐legged dynamic knee‐extensor moderate‐intensity exercise, as well as changes in key proteins in muscle metabolism before and after exercise.Age and immobilization did not affect relative carbohydrate and fat utilization during exercise, but the older men had higher uptake of exogenous fatty acids, whereas the young men relied more on endogenous fatty acids during exercise.Using a combined whole‐leg and molecular approach, we provide evidence that both age and physical inactivity result in intramuscular lipid accumulation, but this occurs only in part through the same mechanisms. Abstract Age and inactivity have been associated with intramuscular triglyceride (IMTG) accumulation. Here, we attempt to disentangle these factors by studying the effect of 2 weeks of unilateral leg immobilization on substrate utilization across the legs during moderate‐intensity exercise in young (n = 17; 23 ± 1 years old) and older men (n = 15; 68 ± 1 years old), while the contralateral leg served as the control. After immobilization, the participants performed two‐legged isolated knee‐extensor exercise at 20 ± 1 W (∼50% maximal work capacity) for 45 min with catheters inserted in the brachial artery and both femoral veins. Biopsy samples obtained from vastus lateralis muscles of both legs before and after exercise were used for analysis of substrates, protein content and enzyme activities. During exercise, leg substrate utilization (respiratory quotient) did not differ between groups or legs. Leg fatty acid uptake was greater in older than in young men, and although young men demonstrated net leg glycerol release during exercise, older men showed net glycerol uptake. At baseline, IMTG, muscle pyruvate dehydrogenase complex activity and the protein content of adipose triglyceride lipase, acetyl‐CoA carboxylase 2 and AMP‐activated protein kinase (AMPK)γ3 were higher in young than in older men. Furthermore, adipose triglyceride lipase, plasma membrane‐associated fatty acid binding protein and AMPKγ3 subunit protein contents were lower and IMTG was higher in the immobilized than the contralateral leg in young and older men. Thus, immobilization and age did not affect substrate choice (respiratory quotient) during moderate exercise, but the whole‐leg and molecular differences in fatty acid mobilization could explain the age‐ and immobilization‐induced IMTG accumulation. PMID:26801521
1975-10-08
m AD-A020 796 A POSTULATED MECHANISM THAT LEADS TO MATERIALIZATION AND DEMATERIALIZATION OF MATTER AND TO ANTIGRAVITY Thomas E. Bearden Army...TITLE fand Subtlll») A POSTULATED MECHANISM THAT LEADS TO MATERIALIZATION AND DEMATERIALIZATION OF MATTER AND TO ANTIGRAVITY S. TYPE OF REPORT... Antigravity 1 Three-dimensional space Photon Orthogonal frames i I
Brachiopod δ18O values do reflect ambient oceanography: Lacepede Shelf, southern Australia
NASA Astrophysics Data System (ADS)
James, Noel P.; Bone, Yvonne; Kurtis Kyser, T.
1997-06-01
Although commonly used as proxies for attributes of ancient ocean waters, the δ18O values of brachiopods from modern seas are little studied. To evaluate the utility of brachiopods as recorders of regional oceanography, modern shells from the Lacepede Shelf (25 000 km2) of southern Australia were analyzed for δ18O, and the results were compared to the values of ambient seawater. Southern Ocean waters cover this area of extensive cool-water carbonate deposition, but there are distinct sectors of seasonal upwelling and lesser fluvial outflow. δ18O values of brachiopods across the environmental spectrum from 40 to 300 m water depth are in general isotopic equilibrium with surrounding seawater. Nevertheless, δ18O values from individual sample sites vary as much as 0.60‰. The area of cold-water upwelling in particular is clearly delimited by a group of high δ18O values. The range of values across this one shelf, on the order of 2.5‰, is similar to the range of values postulated on the basis of similar results for secular changes in many ancient oceans.
Hyperthyroidism with Periodic Paralysis
Feldman, David L.; Goldberg, W. M.
1969-01-01
Hyperthyroidism may be associated with hypokalemic periodic paralysis. Two cases are presented demonstrating intermittent attacks of flaccid paralysis associated with clinical symptoms, signs and laboratory findings of hyperthyroidism. During an attack, one patient had a serum potassium of 2.1 mEq. per litre. Various factors such as trauma, exposure to cold, excessive carbohydrate ingestion and certain medications have been stated to precipitate an episode of paralysis. Attacks may range from mild weakness to generalized flaccid paralysis with loss of deep tendon reflexes. Several reported patients have died owing to cardiac arrest or respiratory paralysis. During attacks, the serum potassium is usually in the range of 2.2 to 3.2 mEq. per litre. It is postulated that a metabolic abnormality affecting the muscle-cell membrane can occur in the hyperthyroid state resulting in a shift of potassium to the intracellular position, thus producing a situation of hyperpolarization of the muscle-cell membrane which in turn alters the muscle contractibility. The importance of recognizing the unusual association of hypokalemic periodic paralysis with hyperthyroidism is stressed because, with successful treatment of the hyperthyroidism, the episodes of paralysis disappear. PMID:5353150
TRF2 and the evolution of the bilateria.
Duttke, Sascha H C; Doolittle, Russell F; Wang, Yuan-Liang; Kadonaga, James T
2014-10-01
The development of a complex body plan requires a diversity of regulatory networks. Here we consider the concept of TATA-box-binding protein (TBP) family proteins as "system factors" that each supports a distinct set of transcriptional programs. For instance, TBP activates TATA-box-dependent core promoters, whereas TBP-related factor 2 (TRF2) activates TATA-less core promoters that are dependent on a TCT or downstream core promoter element (DPE) motif. These findings led us to investigate the evolution of TRF2. TBP occurs in Archaea and eukaryotes, but TRF2 evolved prior to the emergence of the bilateria and subsequent to the evolutionary split between bilaterians and nonbilaterian animals. Unlike TBP, TRF2 does not bind to the TATA box and could thus function as a new system factor that is largely independent of TBP. We postulate that this TRF2-based system served as the foundation for new transcriptional programs, such as those involved in triploblasty and body plan development, that facilitated the evolution of bilateria. © 2014 Duttke et al.; Published by Cold Spring Harbor Laboratory Press.
NASA Technical Reports Server (NTRS)
Kadambi, J. R.; Schneider, S. J.; Stewart, W. A.
1986-01-01
The natural circulation of a single phase fluid in a scale model of a pressurized water reactor system during a postulated grade core accident is analyzed. The fluids utilized were water and SF6. The design of the reactor model and the similitude requirements are described. Four LDA tests were conducted: water with 28 kW of heat in the simulated core, with and without the participation of simulated steam generators; water with 28 kW of heat in the simulated core, with the participation of simulated steam generators and with cold upflow of 12 lbm/min from the lower plenum; and SF6 with 0.9 kW of heat in the simulated core and without the participation of the simulated steam generators. For the water tests, the velocity of the water in the center of the core increases with vertical height and continues to increase in the upper plenum. For SF6, it is observed that the velocities are an order of magnitude higher than those of water; however, the velocity patterns are similar.
Wall Pressure Unsteadiness and Side Loads in Overexpanded Rocket Nozzles
NASA Technical Reports Server (NTRS)
Baars, Woutijn J.; Tinney, Charles E.; Ruf, Joseph H.; Brown, Andrew M.; McDaniels, David M.
2012-01-01
Surveys of both the static and dynamic wall pressure signatures on the interior surface of a sub-scale, cold-flow and thrust optimized parabolic nozzle are conducted during fixed nozzle pressure ratios corresponding to FSS and RSS states. The motive is to develop a better understanding for the sources of off-axis loads during the transient start-up of overexpanded rocket nozzles. During FSS state, pressure spectra reveal frequency content resembling SWTBLI. Presumably, when the internal flow is in RSS state, separation bubbles are trapped by shocks and expansion waves; interactions between the separated flow regions and the waves produce asymmetric pressure distributions. An analysis of the azimuthal modes reveals how the breathing mode encompasses most of the resolved energy and that the side load inducing mode is coherent with the response moment measured by strain gauges mounted upstream of the nozzle on a flexible tube. Finally, the unsteady pressure is locally more energetic during RSS, albeit direct measurements of the response moments indicate higher side load activity when in FSS state. It is postulated that these discrepancies are attributed to cancellation effects between annular separation bubbles.
33 CFR 147.809 - Mars Tension Leg Platform safety zone.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...
33 CFR 147.809 - Mars Tension Leg Platform safety zone.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...
33 CFR 147.809 - Mars Tension Leg Platform safety zone.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...
33 CFR 147.809 - Mars Tension Leg Platform safety zone.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...
33 CFR 147.809 - Mars Tension Leg Platform safety zone.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...
Raibert, M H
1986-03-14
Symmetry plays a key role in simplifying the control of legged robots and in giving them the ability to run and balance. The symmetries studied describe motion of the body and legs in terms of even and odd functions of time. A legged system running with these symmetries travels with a fixed forward speed and a stable upright posture. The symmetries used for controlling legged robots may help in elucidating the legged behavior of animals. Measurements of running in the cat and human show that the feet and body sometimes move as predicted by the even and odd symmetry functions.
Determination of muscle mass changes in legs from K-40 measurements
NASA Technical Reports Server (NTRS)
Palmer, H. E.; Rieksts, G. A.
1979-01-01
The K-40 content of the upper legs was periodically measured in several subjects whose injured legs had been in a cast for 6 weeks or more. As the subjects began using the leg again, the K-40 content increased as the muscle tissue was replaced. A 25% increase in K-40 content in 6 months is typical for a normal leg use and recovery. This is equivalent to an original muscle mass loss of 20%. By measuring specific body regions, such as arms or legs, with a high-efficiency detector system, muscle mass changes which exceed a few percent can be measured. These methods could be used in space flight and bedrest studies, and in studying nutritional deficiencies due to disease or diet.
... are important for motion and standing. Playing sports, running, falling, or having an accident can damage your legs. Common leg injuries include sprains and strains, joint dislocations, and fractures. ...
Michard, Céline; Sperandio, Daniel; Baïlo, Nathalie; Pizarro-Cerdá, Javier; LeClaire, Lawrence; Chadeau-Argaud, Elise; Pombo-Grégoire, Isabel; Hervet, Eva; Vianney, Anne; Gilbert, Christophe; Faure, Mathias; Cossart, Pascale
2015-01-01
ABSTRACT Legionella pneumophila, the etiological agent of legionellosis, replicates within phagocytic cells. Crucial to biogenesis of the replicative vacuole is the Dot/Icm type 4 secretion system, which translocates a large number of effectors into the host cell cytosol. Among them is LegK2, a protein kinase that plays a key role in Legionella infection. Here, we identified the actin nucleator ARP2/3 complex as a target of LegK2. LegK2 phosphorylates the ARPC1B and ARP3 subunits of the ARP2/3 complex. LegK2-dependent ARP2/3 phosphorylation triggers global actin cytoskeleton remodeling in cells, and it impairs actin tail formation by Listeria monocytogenes, a well-known ARP2/3-dependent process. During infection, LegK2 is addressed to the Legionella-containing vacuole surface and inhibits actin polymerization on the phagosome, as revealed by legK2 gene inactivation. Consequently, LegK2 prevents late endosome/lysosome association with the phagosome and finally contributes to remodeling of the bacterium-containing phagosome into a replicative niche. The inhibition of actin polymerization by LegK2 and its effect on endosome trafficking are ARP2/3 dependent since it can be phenocopied by a specific chemical inhibitor of the ARP2/3 complex. Thus, LegK2-ARP2/3 interplay highlights an original mechanism of bacterial virulence with an unexpected role in local actin remodeling that allows bacteria to control vesicle trafficking in order to escape host defenses. PMID:25944859
Auvinen, Piritta; Mäntyselkä, Pekka; Koponen, Hannu; Kautiainen, Hannu; Korniloff, Katariina; Ahonen, Tiina; Vanhala, Mauno
2018-01-01
Restless legs syndrome is a sensorimotor disorder and it is associated with several other diseases especially mental illnesses. To analyze the relationship between the symptoms of restless legs syndrome and the severity of depressive symptoms and the prevalence of restless legs symptoms in depression subtypes. A cross-sectional study of primary care patients in the Central Finland Hospital District. The prevalence of restless legs symptoms was studied in 706 patients with increased depressive symptoms and 426 controls without a psychiatric diagnosis by using a structured questionnaire. The depressive symptoms were evaluated with the Beck Depression Inventory (BDI) and the psychiatric diagnosis was confirmed by means of a diagnostic interview (Mini-International Neuropsychiatric Interview). The subjects with increased depressive symptoms were divided into three groups (subjects with depressive symptoms without a depression diagnosis, melancholic depression and non-melancholic depression). In the whole study population, the prevalence of restless legs symptoms increased with the severity of depressive symptoms. The prevalence of restless legs symptoms was highest in the melancholic and non-melancholic depressive patients (52 and 46%, respectively) and then in subjects with depressive symptoms without a depression diagnosis (43.4%), but the prevalence was also substantial (24.6%) in subjects without a psychiatric diagnosis. Restless legs symptoms are very common in primary care among subjects with depression, regardless of the depression type. The prevalence of restless legs symptoms increased with increasing severity of depressive symptoms, regardless of the diagnosis. These findings should be considered in clinical evaluation and treatment of patients visiting their physician due to restless legs or depressive symptoms.
Method for six-legged robot stepping on obstacles by indirect force estimation
NASA Astrophysics Data System (ADS)
Xu, Yilin; Gao, Feng; Pan, Yang; Chai, Xun
2016-07-01
Adaptive gaits for legged robots often requires force sensors installed on foot-tips, however impact, temperature or humidity can affect or even damage those sensors. Efforts have been made to realize indirect force estimation on the legged robots using leg structures based on planar mechanisms. Robot Octopus III is a six-legged robot using spatial parallel mechanism(UP-2UPS) legs. This paper proposed a novel method to realize indirect force estimation on walking robot based on a spatial parallel mechanism. The direct kinematics model and the inverse kinematics model are established. The force Jacobian matrix is derived based on the kinematics model. Thus, the indirect force estimation model is established. Then, the relation between the output torques of the three motors installed on one leg to the external force exerted on the foot tip is described. Furthermore, an adaptive tripod static gait is designed. The robot alters its leg trajectory to step on obstacles by using the proposed adaptive gait. Both the indirect force estimation model and the adaptive gait are implemented and optimized in a real time control system. An experiment is carried out to validate the indirect force estimation model. The adaptive gait is tested in another experiment. Experiment results show that the robot can successfully step on a 0.2 m-high obstacle. This paper proposes a novel method to overcome obstacles for the six-legged robot using spatial parallel mechanism legs and to avoid installing the electric force sensors in harsh environment of the robot's foot tips.
Leg stiffness and expertise in men jumping.
Laffaye, Guillaume; Bardy, Benoît G; Durey, Alain
2005-04-01
The aim of the present study is to investigate: a) the leg spring behavior in the one-leg vertical jump, b) the contribution of impulse parameters to this behavior, and c) the effect of jumping expertise on leg stiffness. Four categories of experts (handball, basketball, volleyball players, and Fosbury athletes), as well as novice subjects performed a run-and-jump test to touch a ball with the head. Five experimental conditions were tested from 55 to 95% of the maximum jump height. Kinematic and kinetic data were collected using six cameras and a force plate. The mechanical behavior of the musculoskeleton component of the human body can be modeled as a simple mass-spring system, from which leg stiffness values can be extracted to better understand energy transfer during running or jumping. The results indicate that leg stiffness (mean value of 11.5 kN.m) decreased with jumping height. Leg shortening at takeoff also increased with jumping height, whereas contact time decreased (-18%). No difference was found between experts and novices for leg stiffness. However, a principal components analysis (PCA) indicated the contribution of two main factors to the performance. The first factor emerged out of vertical force, stiffness, and duration of impulse. The second factor included leg shortening and jumping height. Differences between experts and novices were observed in terms of the contribution of leg stiffness to jump height, and more importantly, clear differences existed between experts in jumping parameters. The analysis performed on the sport categories indeed revealed different jumping profiles, characterized by specific, sport-related impulse parameters.
Yorozu, Ayanori; Moriguchi, Toshiki; Takahashi, Masaki
2015-09-04
Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull-Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).
Willardson, Jeffrey M; Bressel, Eadric
2004-08-01
The purpose of this research was to devise prediction equations whereby a 10 repetition maximum (10RM) for the free weight parallel squat could be predicted using the following predictor variables: 10RM for the 45 degrees angled leg press, body mass, and limb length. Sixty men were tested over a 3-week period, with 1 testing session each week. During each testing session, subjects performed a 10RM for the free weight parallel squat and 45 degrees angled leg press. Stepwise multiple regression analysis showed leg press mass lifted to be a significant predictor of squat mass lifted for both the advanced and the novice groups (p < 0.05). Leg press mass lifted accounted for approximately 25% of the variance in squat mass lifted for the novice group and 55% of the variance in squat mass lifted for the advanced group. Limb length and body mass were not significant predictors of squat mass lifted for either group. The following prediction equations were devised: (a) novice group squat mass = leg press mass (0.210) + 36.244 kg, (b) advanced group squat mass = leg press mass (0.310) + 19.438 kg, and (c) subject pool squat mass = leg press mass (0.354) + 2.235 kg. These prediction equations may save time and reduce the risk of injury when switching from the leg press to the squat exercise.
Directionally compliant legs influence the intrinsic pitch behaviour of a trotting quadruped
Lee, David V; Meek, Sanford G
2005-01-01
Limb design is well conserved among quadrupeds, notably, the knees point forward (i.e. cranial inclination of femora) and the elbows point back (i.e. caudal inclination of humeri). This study was undertaken to examine the effects of joint orientation on individual leg forces and centre of mass dynamics. Steady-speed trotting was simulated in two quadrupedal models. Model I had the knee and elbow orientation of a quadruped and model II had a reversed leg configuration in which knees point back and elbows point forward. The model's legs showed directional compliance determined by the orientation of the knee/elbow. In both models, forward pointing knees/elbows produced a propulsive force bias, while rearward pointing knees/elbows produced a braking force bias. Hence, model I showed the same pattern of hind-leg propulsion and fore-leg braking observed in trotting animals. Simulations revealed minimal pitch oscillations during steady-speed trotting of model I, but substantially greater and more irregular pitch oscillations of model II. The reduced pitch oscillation of model I was a result of fore-leg and hind-leg forces that reduced pitching moments during early and late stance, respectively. This passive mechanism for reducing pitch oscillations was an emergent property of directionally compliant legs with the fore–hind configuration of model I. Such intrinsic stability resulting from mechanical design can simplify control tasks and lead to more robust running machines. PMID:15817430
Heers, Ashley M; Dial, Kenneth P
2015-02-01
Wings have long been regarded as a hallmark of evolutionary innovation, allowing insects, birds, and bats to radiate into aerial environments. For many groups, our intuitive and colloquial perspective is that wings function for aerial activities, and legs for terrestrial, in a relatively independent manner. However, insects and birds often engage their wings and legs cooperatively. In addition, the degree of autonomy between wings and legs may be constrained by tradeoffs, between allocating resources to wings versus legs during development, or between wing versus leg investment and performance (because legs must be carried as baggage by wings during flight and vice versa). Such tradeoffs would profoundly affect the development and evolution of locomotor strategies, and many related aspects of animal ecology. Here, we provide the first evaluation of wing versus leg investment, performance and relative use, in birds-both across species, and during ontogeny in three precocial species with different ecologies. Our results suggest that tradeoffs between wing and leg modules help shape ontogenetic and evolutionary trajectories, but can be offset by recruiting modules cooperatively. These findings offer a new paradigm for exploring locomotor strategies of flying organisms and their extinct precursors, and thereby elucidating some of the most spectacular diversity in animal history. © 2014 The Author(s). Evolution © 2014 The Society for the Study of Evolution.
Demachi, K; Yoshida, T; Kume, M; Tsuneoka, H
2012-07-01
To assess the effects of starting or stopping leg cooling on the thermoregulatory responses during exercise, 60 min of cycling exercise at 30% of maximal oxygen uptake was performed under 4 conditions using tube trouser perfused with water at 10 °C; no leg cooling (NC), starting of leg cooling after 30 min of exercise (delayed cooling, DC), continuous leg cooling (CC), and stopping of continuous leg cooling after 30 min of exercise (SC) at an environmental temperature of 28.5 °C. During exercise under the DC conditions, an instantaneous increase in the esophageal temperature (Tes), a suppression of the cutaneous vascular conductance at the forearm (%CVC), and a decrease in the mean skin temperature (Tsk) were observed after leg cooling. The total sweat loss (Δm sw,tot) was lower under the DC than the NC condition. In the SC study, however, the Tes remained constant, while the %CVC increased gradually after leg cooling was stopped, and the Δm sw,tot was greater than that under the CC condition. These results suggest that during exercise, rapid skin cooling of the leg may cause an increase in core temperature, while also enhancing thermal stress. However, stopping skin cooling did not significantly affect the core temperature long-term, because the skin blood flow and sweat rate subsequently increased. © Georg Thieme Verlag KG Stuttgart · New York.
... feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... 31. Trayes KP, Studdiford JS, Pickle S, Tully AS. Edema: diagnosis and management. Am Fam Physician . 2013;88( ...
The Legs Problem--For All Ages
ERIC Educational Resources Information Center
Way, Jenni
2005-01-01
This article presents an example of a versatile multi-solution problem that can be used right across the primary years. The basic problem is: "Noah saw 16 legs go past him into the Ark. How many creatures did he see?" Any even number can be used, although, 2 legs allows only one answer and with 16 legs there are already 14 different…
Flexible pipe crawling device having articulated two axis coupling
Zollinger, William T.
1994-01-01
An apparatus for moving through the linear and non-linear segments of piping systems. The apparatus comprises a front leg assembly, a rear leg assembly, a mechanism for extension and retraction of the front and rear leg assembles with respect to each other, such as an air cylinder, and a pivoting joint. One end of the flexible joint attaches to the front leg assembly and the other end to the air cylinder, which is also connected to the rear leg assembly. The air cylinder allows the front and rear leg assemblies to progress through a pipe in "inchworm" fashion, while the joint provides the flexibility necessary for the pipe crawler to negotiate non-linear piping segments. The flexible connecting joint is coupled with a spring-force suspension system that urges alignment of the front and rear leg assemblies with respect to each other. The joint and suspension system cooperate to provide a firm yet flexible connection between the front and rear leg assemblies to allow the pivoting of one with respect to the other while moving around a non-linear pipe segment, but restoring proper alignment coming out of the pipe bend.
Evaluation of Thermoelectric Performance and Durability of Functionalized Skutterudite Legs
NASA Astrophysics Data System (ADS)
Skomedal, Gunstein; Kristiansen, Nils R.; Sottong, Reinhard; Middleton, Hugh
2017-04-01
Thermoelectric generators are a promising technology for waste heat recovery. As new materials and devices enter a market penetration stage, it is of interest to employ fast and efficient measurement methods to evaluate the long-term stability of thermoelectric materials in combination with metallization and coating (functionalized thermoelectric legs). We have investigated a method for measuring several thermoelectric legs simultaneously. The legs are put under a common temperature gradient, and the electrical characteristics of each leg are measured individually during thermal cycling. Using this method, one can test different types of metallization and coating applied to skutterudite thermoelectric legs and look at the relative changes over time. Postcharacterization of these initial tests with skutterudite legs using a potential Seebeck microprobe and an electron microscope showed that oxidation and interlayer diffusion are the main reasons for the gradual increase in internal resistance and the decrease in open-circuit voltage. Although we only tested skutterudite material in this work, the method is fully capable of testing all kinds of material, metallization, and coating. It is thus a promising method for studying the relationship between failure modes and mechanisms of functionalized thermoelectric legs.
Modification of Impulse Generation During Pirouette Turns With Increased Rotational Demands.
Zaferiou, Antonia M; Wilcox, Rand R; McNitt-Gray, Jill L
2016-10-01
This study determined how dancers regulated angular and linear impulse during the initiation of pirouettes of increased rotation. Skilled dancers (n = 11) performed single and double pirouette turns with each foot supported by a force plate. Linear and angular impulses generated by each leg were quantified and compared between turn types using probability-based statistical methods. As rotational demands increased, dancers increased the net angular impulse generated. The contribution of each leg to net angular impulse in both single and double pirouettes was influenced by stance configuration strategies. Dancers who generated more angular impulse with the push leg than with the turn leg initiated the turn with the center of mass positioned closer to the turn leg than did other dancers. As rotational demands increased, dancers tended to increase the horizontal reaction force magnitude at one or both feet; however, they used subject-specific mechanisms. By coordinating the generation of reaction forces between legs, changes in net horizontal impulse remained minimal, despite impulse regulation at each leg used to achieve more rotations. Knowledge gained regarding how an individual coordinates the generation of linear and angular impulse between both legs as rotational demand increased can help design tools to improve that individual's performance.
Flexible pipe crawling device having articulated two axis coupling
Zollinger, W.T.
1994-05-10
An apparatus is described for moving through the linear and non-linear segments of piping systems. The apparatus comprises a front leg assembly, a rear leg assembly, a mechanism for extension and retraction of the front and rear leg assembles with respect to each other, such as an air cylinder, and a pivoting joint. One end of the flexible joint attaches to the front leg assembly and the other end to the air cylinder, which is also connected to the rear leg assembly. The air cylinder allows the front and rear leg assemblies to progress through a pipe in inchworm' fashion, while the joint provides the flexibility necessary for the pipe crawler to negotiate non-linear piping segments. The flexible connecting joint is coupled with a spring-force suspension system that urges alignment of the front and rear leg assemblies with respect to each other. The joint and suspension system cooperate to provide a firm yet flexible connection between the front and rear leg assemblies to allow the pivoting of one with respect to the other while moving around a non-linear pipe segment, but restoring proper alignment coming out of the pipe bend. 4 figures.
Balik, Mehmet Sabri; Kanat, Ayhan; Erkut, Adem; Ozdemir, Bulent; Batcik, Osman Ersagun
2016-01-01
Objective: Inequality in leg length may lead to to abnormal transmission of load across the endplates and degeneration lumbar spine and the disc space. There has been no study focusing on lumbar disc herniation (LDH) and leg length discrepancy. This subject was investigated in this study. Materials and Methods: Consecutive adult patients with leg length discrepancy and low back pain (LBP) admitted to our department were respectivelly studied. Results: A total number of 39 subjects (31 women and eight men) with leg length discrepancy and LBP and 43 (25 females and 18 males) patients with LBP as a control group were tested. Occurrence of disc herniation is statistically different between patients with hip dysplasia and control groups (P < 0.05). Conclusion: The results of this study showed a statistically significant association between leg length discrepancy and occurrence of LDH. The changes of spine anatomy with leg length discrepancy in hip dysplastic patients are of importance in understanding the nature of LDH. PMID:27217654
A Force-Sensing System on Legs for Biomimetic Hexapod Robots Interacting with Unstructured Terrain
Wu, Rui; Li, Changle; Zang, Xizhe; Zhang, Xuehe; Jin, Hongzhe; Zhao, Jie
2017-01-01
The tiger beetle can maintain its stability by controlling the interaction force between its legs and an unstructured terrain while it runs. The biomimetic hexapod robot mimics a tiger beetle, and a comprehensive force sensing system combined with certain algorithms can provide force information that can help the robot understand the unstructured terrain that it interacts with. This study introduces a complicated leg force sensing system for a hexapod robot that is the same for all six legs. First, the layout and configuration of sensing system are designed according to the structure and sizes of legs. Second, the joint toque sensors, 3-DOF foot-end force sensor and force information processing module are designed, and the force sensor performance parameters are tested by simulations and experiments. Moreover, a force sensing system is implemented within the robot control architecture. Finally, the experimental evaluation of the leg force sensor system on the hexapod robot is discussed and the performance of the leg force sensor system is verified. PMID:28654003
Coordination of planar cell polarity pathways through Spiny-legs
Ambegaonkar, Abhijit A; Irvine, Kenneth D
2015-01-01
Morphogenesis and physiology of tissues and organs requires planar cell polarity (PCP) systems that orient and coordinate cells and their behaviors, but the relationship between PCP systems has been controversial. We have characterized how the Frizzled and Dachsous-Fat PCP systems are connected through the Spiny-legs isoform of the Prickle-Spiny-legs locus. Two different components of the Dachsous-Fat system, Dachsous and Dachs, can each independently interact with Spiny-legs and direct its localization in vivo. Through characterization of the contributions of Prickle, Spiny-legs, Dachsous, Fat, and Dachs to PCP in the Drosophila wing, eye, and abdomen, we define where Dachs-Spiny-legs and Dachsous-Spiny-legs interactions contribute to PCP, and provide a new understanding of the orientation of polarity and the basis of PCP phenotypes. Our results support the direct linkage of PCP systems through Sple in specific locales, while emphasizing that cells can be subject to and must ultimately resolve distinct, competing PCP signals. DOI: http://dx.doi.org/10.7554/eLife.09946.001 PMID:26505959
Mechanical energy storage device for hip disarticulation
NASA Technical Reports Server (NTRS)
Vallotton, W. C. (Inventor)
1977-01-01
An artificial leg including a trunk socket, a thigh section hingedly coupled to the trunk socket, a leg section hingedly coupled to the thigh section and a foot section hingedly coupled to the leg section is outlined. A mechanical energy storage device is operatively associated with the artificial leg for storage and release of energy during the normal walking stride of the user. Energy is stored in the mechanical energy storage device during a weight-bearing phase of the walking stride when the user's weight is on the artificial leg. Energy is released during a phase of the normal walking stride, when the user's weight is removed from the artificial leg. The stored energy is released from the energy storage device to pivot the thigh section forwardly about the hinged coupling to the trunk socket.
Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg
Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej
2015-01-01
The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the intact leg and smaller than that of the control group. The total knee flexions in the laboratory measurements were comparable with field measurements. Additional load affects the RoM of the ski boot, ankle and knee joints for the amputated skier in both legs. No significant influence from the additional load was found on the RoM in the control group of healthy subjects. The above-knee prosthesis with a multiple-axis prosthetic knee reproduces the alpine skiing kinematics of an intact leg. PMID:26664282
Mechanism And Control Of The Quadruped Walking Robot
NASA Astrophysics Data System (ADS)
Adachi, Hironori; Nakano, Eiji; Koyachi, Noriho
1987-10-01
This paper provides a description of the quadruped walking robot "TURTLE-1". A new link mechanism named ASTBALLEM is used for the legs of this robot. With this mechanism highly rigid and easily controllable legs are constructed. Each leg has two degrees of freedom and is driven by two DC servo motors. The motion of the legs is controlled by a micro computer and various gaits are generated. Static stability is maintained as the robot walks. Moreover, its walk is quasi-dynamic; that is, it has a manner of walking that has a two legged supporting period.
Wells, Jonathan C K
2012-02-01
In the 19th century, two "ecogeographical rules" were proposed hypothesizing associations of climate with mammalian body size and proportions. Data on human body weight and relative leg length support these rules; however, it is unknown whether such associations are attributable to lean tissue (the heat-producing component) or fat (energy stores). Data on weight, height, and two skinfold thickness were obtained from the literature for 137 nonindustrialized populations, providing 145 male and 115 female individual samples. A variety of indices of adiposity and lean mass were analyzed. Preliminary analyses indicated secular increases in skinfolds in men but not women, and associations of age and height with lean mass in both sexes. Decreasing annual temperature was associated with increasing body mass index (BMI), and increasing triceps but not subscapular skinfold. After adjusting for skinfolds, decreasing temperature remained associated with increasing BMI. These results indicate that colder environments favor both greater peripheral energy stores, and greater lean mass. Contrasting results for triceps and subscapular skinfolds might be due to adaptive strategies either constraining central adiposity in cold environments to reduce cardiovascular risk, or favoring central adiposity in warmer environments to maintain energetic support of the immune system. Polynesian populations were analyzed separately and contradicted all of the climate trends, indicating support for the hypothesis that they are cold-adapted despite occupying a tropical region. It is unclear whether such associations emerge through natural selection or through trans-generational and life-course plasticity. These findings nevertheless aid understanding of the wide variability in human physique and adiposity. Copyright © 2011 Wiley Periodicals, Inc.
Crampton, D; Egaña, M; Donne, B; Warmington, S A
2014-08-01
Sprint (high-intensity) exercise performance is reduced when immediately preceded by cold water immersion (CWI). We aimed to investigate whether this performance effect could be attenuated by combining an active recovery (arm exercise) with hip-level CWI, and whether this attenuation may be related to an effect on core temperature (Tcore ). Participants (n = 8) completed three Wingate tests before (Ex1) and after (Ex2) four different 30-min recovery interventions: CWI at 15 °C (CW15), arm exercise during CWI at 15 °C (CW15+AE), arm exercise during thermoneutral immersion at 34 °C (TW34+AE) and non-immersed arm exercise (AE). After AE and TW34+AE, performance during Ex2 was not different from Ex1; while after CW15+AE and CW15, performance was reduced by 4.9% and 7.6%, respectively. Arm exercise maintained Tcore during recovery in CW15+AE, while it declined to a larger extent upon commencement of Ex2 (-0.9 °C) when compared with CW15 (-0.6 °C). This suggests similar leg muscle cooling during recovery in CW15 and CW15+AE. Without any other significant effects (e.g., on blood lactate), these data suggest that the improvement in sprint performance following an active CWI recovery, over CWI alone, may be related to maintained Tcore and its effect on neurophysiological mechanisms that drive muscle activation, but not by reduced muscle cooling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zheng, Zhen; Wang, Kelun; Yao, Dongyuan; Xue, Charlie C L; Arendt-Nielsen, Lars
2014-05-01
This study investigated the relationship between pain sensitivity, adaptability, and potency of endogenous pain inhibition, including conditioned pain modulation (CPM) and local pain inhibition. Forty-one healthy volunteers (20 male, 21 female) received conditioning stimulation (CS) over 2 sessions in a random order: tonic heat pain (46 °C) on the right leg for 7 minutes and cold pressor pain (1 °C to 4 °C) on the left hand for 5 minutes. Participants rated the intensity of pain continuously using a 0 to 10 electronic visual analogue scale. The primary outcome measures were pressure pain thresholds (PPT) measured at the heterotopic and homotopic location to the CS sites before, during, and 20 minutes after CS. Two groups of participants, pain adaptive and pain nonadaptive, were identified based on their response to pain in the cold pressor test. Pain-adaptive participants showed a pain reduction between peak pain and pain at end of the test by at least 2 of 10 (n=16); whereas the pain-nonadaptive participants reported unchanged peak pain during 5-minute CS (n=25). Heterotopic PPTs during the CS did not differ between the 2 groups. However, increased homotopic PPTs measured 20 minutes after CS correlated with the amount of pain reduction during CS. These results suggest that individual sensitivity and adaptability to pain does not correlate with the potency of CPM. Adaptability to pain is associated with longer-lasting local pain inhibition. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
2014-03-20
Strain of Muscle and/or Tendon of Lower Leg; Fracture of Lower Leg; Crushing Injury of Lower Leg; Fracture Malunion - Ankle and/or Foot; Disorder of Joint of Ankle and/or Foot; Complete Tear, Ankle and/or Foot Ligament; Pathological Fracture - Ankle and/or Foot; Loose Body in Joint of Ankle and/or Foot
ERIC Educational Resources Information Center
Andreacci, Joseph L.; Nagle, Trisha; Fitzgerald, Elise; Rawson, Eric S.; Dixon, Curt B.
2013-01-01
Purpose: We examined the impact that cycle ergometry exercise had on percent body fat (%BF) estimates when assessed using either leg-to-leg or segmental bioelectrical impedance analysis (LBIA; SBIA) and whether the intensity of the exercise bout impacts the %BF magnitude of change. Method: Seventy-four college-aged adults participated in this…
Troester, Jordan C.; Jasmin, Jason G.; Duffield, Rob
2018-01-01
The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test – re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union. Key points Single-leg balance demonstrated acceptable inter-trial and inter-test reliability. Single-leg landing demonstrated good inter-trial and inter-test reliability for measures of relative peak landing force and relative impulse, but not time to stabilization. Of the variables investigated, sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing respectively, and should considered for monitoring changes in postural control. PMID:29769817
Vaisman, Alex; Guiloff, Rodrigo; Rojas, Juan; Delgado, Iris; Figueroa, David; Calvo, Rafael
2017-12-01
Achieving a symmetrical power performance (difference <15%) between lower limbs is generally recommended during sports rehabilitation. However, athletes in single-leg-dominant sports, such as professional soccer players, could develop significant asymmetry between their dominant and nondominant legs, such that symmetry does not act as a viable comparison. To (1) compare maximal muscular power between the dominant and nondominant legs in healthy young adults, (2) evaluate the effect of a single-leg-dominant sport activity performed at the professional level, and (3) propose a parameter of normality for maximal power difference in the lower limbs of this young adult population. Controlled laboratory study. A total of 78 healthy, male, young adults were divided into 2 groups according to sport activity level. Group 1 consisted of 51 nonathletes (mean ± SD age, 20.8 ± 1.5 years; weight, 71.9 ± 10.5 kg) who participated in less than 8 hours a week of recreational physical activity with nonspecific training; group 2 consisted of 27 single-leg-dominant professional soccer players (age, 18.4 ± 0.6 years; weight, 70.1 ± 7.5 kg) who specifically trained and competed at their particular activity 8 hours or more a week. For assessment of maximal leg power, both groups completed the single-leg squat jump test. Dominance was determined when participants completed 2 of 3 specific tests with the same extremity. Statistical analysis included the Student t test. No statistical difference was found for maximal power between dominant and nondominant legs for nonathletes ( t = -1.01, P = .316) or single-leg-dominant professional soccer players ( t = -1.10, P = .281). A majority (95%) of participants studied showed a power difference of less than 15% between their lower extremities. Among young healthy adults, symmetrical power performance is expected between lower extremities independent of the existence of dominance and difference in sport activity level. A less than 15% difference in power seems to be a proper parameter to define symmetrical power performance assessed by vertical single-leg jump tests.
Hall, Michael P.; Paik, Ronald S.; Ware, Anthony J.; Mohr, Karen J.; Limpisvasti, Orr
2015-01-01
Background: Criteria for return to unrestricted activity after anterior cruciate ligament (ACL) reconstruction varies, with some using time after surgery as the sole criterion—most often at 6 months. Patients may have residual neuromuscular deficits, which may increase the risk of ACL injury. A single-leg squat test (SLST) can dynamically assess for many of these deficits prior to return to unrestricted activity. Hypothesis: A significant number of patients will continue to exhibit neuromuscular deficits with SLST at 6 months after ACL reconstruction. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Patients using a standardized accelerated rehabilitation protocol at their 6-month follow-up after primary ACL reconstruction were enrolled. Evaluation included bilateral SLST, single-leg hop distance, hip abduction strength, and the subjective International Knee Documentation Committee (IKDC) score. Results: Thirty-three patients were enrolled. Poor performance of the operative leg SLST was found in 15 of 33 patients (45%). Of those 15 patients, 7 (45%) had concomitant poor performance of the nonoperative leg compared with 2 of 18 patients (11%) in those who demonstrated good performance in the operative leg. The poor performers were significantly older (33.6 years) than the good performers (24.2 years) (P = .007). Those with poor performance demonstrated decreased hip abduction strength (17.6 kg operative leg vs 20.5 kg nonoperative leg) (P = .024), decreased single-leg hop distance (83.3 cm operative leg vs 112.3 cm nonoperative leg) (P = .036), and lower IKDC scores (67.9 vs 82.3) (P = .001). Conclusion: Nearly half of patients demonstrated persistent neuromuscular deficits on SLST at 6 months, which is when many patients return to unrestricted activity. Those with poor performance were of a significantly older age, decreased hip abduction strength, decreased single-leg hop distance, and lower IKDC subjective scores. Clinical Relevance: The SLST can be used to identify neuromuscular risk factors for ACL rupture. Many patients at 6 months have persistent neuromuscular deficits on SLST. Caution should be used when using time alone to determine when patients can return to unrestricted activity. PMID:26665033
Yu, Dan; Chen, Ming; Tang, Qiongying; Li, Xiaojuan; Liu, Huanzhang
2014-10-25
Rhynchocypris oxycephalus is a cold water fish with a wide geographic distribution including the relatively warm temperate regions of southern China. It also occurs in second- and third-step geomorphic areas in China. Previous studies have postulated that high-altitude populations of R. oxycephalus in southern China are Quaternary glacial relics. In this study, we used the mitochondrial gene Cytb and the nuclear gene RAG2 to investigate the species phylogeographical patterns and to test two biogeographic hypotheses: (1) that divergence between lineages supports the three-step model and (2) climatic fluctuations during the Quaternary resulted in the present distribution in southern China. Phylogenetic analysis detected three major matrilines (A, B, and C); with matrilines B and C being further subdivided into two submatrilines. Based on genetic distances and morphological differences, matriline A potentially represents a cryptic subspecies. The geographic division between matrilines B and C coincided with the division of the second and third geomorphic steps in China, suggesting a historical vicariance event. Pliocene climatic fluctuations might have facilitated the southwards dispersal of R. oxycephalus in matriline C, with the subsequent warming resulting in its split into submatrilines C1 and C2, leaving submatriline C2 as a relic in southern China. Our study demonstrates that geological events (three steps orogenesis) and climate fluctuations during the Pliocene were important factors in shaping phylogeographical patterns in R. oxycephalus. Notably, no genetic diversity was detected in several populations, all of which possessed unique genotypes. This indicates the uniqueness of local populations and calls for a special conservation plan for the whole species at the population level.
Illness perceptions and coping determine quality of life in COPD patients.
Tiemensma, Jitske; Gaab, Erin; Voorhaar, Maarten; Asijee, Guus; Kaptein, Adrian A
2016-01-01
A key goal of chronic obstructive pulmonary disease (COPD) care is to improve patients' quality of life (QoL). For outcomes such as QoL, illness perceptions and coping are important determinants. The primary aim was to assess the associations between illness perceptions, coping and QoL in COPD patients. A secondary aim was to compare illness perceptions and coping of patients with reference values derived from the literature. A total of 100 patients were included in the study. Patients were asked to complete the Brief Illness Perception Questionnaire (B-IPQ), the Utrecht Proactive Coping Competence scale (UPCC), and a QoL item. Correlations and linear regression models were used to analyze the data. Student's t-tests were used to compare patients with COPD with reference values derived from the literature. Patients with better understanding of COPD utilized more proactive coping strategies (P=0.04). A more intense emotional response to COPD was related to less proactive coping (P=0.02). Patients who reported using more proactive coping techniques also reported to have a better QoL (P<0.01). Illness perceptions were also related to QoL: more positive illness perceptions were related to a better QoL (all P<0.05). Patients with COPD reported more negative illness perceptions than people with a common cold or patients with asthma (all P<0.01), but reported similar perceptions compared with patients with diabetes. Patients with COPD reported a moderate QoL, but appeared to be proficient in proactive coping. Illness perceptions, coping, and QoL were all associated with each other. Patients reported more strongly affected illness perceptions compared to people with a cold and patients with asthma. We postulate that a self-management intervention targeting patients' illness perceptions leads to improved QoL.
Meigal, Alexander Yu
2013-03-01
Here we describe GATO (gravity, age, thermoregulation, and oxygenation) hypothesis (or a "Baby Astronaut" hypothesis) which we suggest to explain synergistic effect of these factors on the motor system. Taken separately, microgravity (in spaceflight, G~0), the early age, heat and hypoxia exert identical effect on the motor system. We posit that synergy of these factors originate from their synchronicity during intrauterine immersion (analog microgravity) of the fetus in warm hypoxic condition. We further postulate three successive motor adaptive strategies, driven lifelong by gravity as the key factor. The first by age, fetal/microgravity (FM)-strategy, induced by the intrauterine immersion of the fetus, is based on domination of fast type muscle fibers. After birth, thought to be analog for landing from orbit, newborn is subjected to combined influence of cooler ambient temperature, normoxia, and 1G Earth gravity, which cooperatively form a slower GE-strategy. Eventually, healthy ageing results in further domination of slow type muscle fibers that forms the slowest (SL)-strategy. Our hypothesis implies that specific sensory conditions may substitute for each other owing to their synergistic action on the motor system. According to GATO hypothesis heating and hypoxia may be considered as "pro-microgravity" factors, while cold and hyperoxia - as "pro-gravity" ones. As such, cold may act as a partial "surrogate" for gravity, estimated as ~0.2G. That may have potential to elaborate countermeasures for muscle atrophy in astronauts either on-board in long-term spaceflight or for post-flight rehabilitation. Based on GATO hypothesis, predictions on muscle remodeling caused by illumination, sound/noise, and gravidity are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Gann, Jeanette C.; Eisner, Lisa B.; Porter, Steve; Watson, Jordan T.; Cieciel, Kristin D.; Mordy, Calvin W.; Yasumiishi, Ellen M.; Stabeno, Phyllis J.; Ladd, Carol; Heintz, Ron A.; Farley, Edward V.
2016-12-01
Changes to physical and chemical oceanographic structure can lead to changes in phytoplankton biomass and growth, which, in-turn, lead to variability in the amount of energy available for transfer to higher trophic levels (e.g., forage fish). In general, age-0 (juvenile) walleye pollock (Gadus chalcogrammus) have been shown to have low fitness (determined by energy density and size), in warm years compared to average or cold years in the southeastern Bering Sea. Contrary to these findings, the year 2007 was a cold year with low fitness of age-0 pollock compared to the transition year of 2006 (transitioning from warm to cold conditions) and cold years, 2008-2011. In late summer/early fall (mid-August through September), significantly lower surface silicic acid concentrations coupled with low phytoplankton production and chlorophyll a (Chl a) biomass were observed in 2007 among 2006-2012 (P<0.05). We postulate that the low silicic acid concentrations may be an indication of reduced surface nutrient flux during summer, leading to low primary productivity (PP). The nutrient replenishing shelf/slope water exchange that occurred during late October-February (2006-2007) indicates that deep-water nutrient/salinity reserves for the start of the 2007 growing season were plentiful and had similar concentrations to other years (2006-2012). The spring bloom magnitude appeared to be slightly below average, and surface silicic acid concentrations at the end of the spring bloom period in 2007 appeared similar to other years in the middle domain of the southeastern Bering Sea. However, during summer (June-August) 2007, high stratification and the low number of storm events resulted in low flux of nutrients to surface waters, indicated by the low surface silicic acid concentrations at the end of summer (mid-August through September). Surface silicic acid may be useful as an indicator of surface nutrient enrichment (and subsequent PP) during summer since other macronutrients (e.g. nitrate) are usually near or below detection limits at this time, and diatoms are generally scarce during summer. Surface silicic acid concentration was also positively associated with the size of juvenile fish (age-0 pollock weight and length). This reinforces the theory that nutrient availability and primary productivity are important to energy allocation for higher trophic levels during summer, and possibly provides links between stratification and wind mixing, surface nutrient input, PP and juvenile fish size and condition.
Sharma, Geeta; Noohu, Majumi Mohamad
2014-09-01
Cryotherapy, in the form of ice massge is used to reduce inflammation after acute musculoskeletal injury or trauma. The potential negative effects of ice massage on proprioception are unknown, despite equivocal evidence supporting its effectiveness. The purpose of the study was to test the influence of cooling on weight discrimination ability and hence the performance in footballers. The study was of same subject experimental design (pretest-posttest design). Thirty male collegiate football players, whose mean age was 21.07 years, participated in the study. The participants were assessed for two functional performance tests, single leg hop test and crossed over hop test and weight discrimination ability before and after ice massage for 5 minutes on hamstrings muscle tendon. Pre cooling scores of Single Leg Hop Test of the dominant leg in the subjects was 166.65 (± 10.16) cm and post cooling scores of the dominant leg was 167.25 (± 11.77) cm. Pre cooling scores of Crossed Over Hop Test of the dominant leg in the subjects was 174.14 (± 8.60) cm and post cooling scores of the dominant leg was 174.45 (± 9.28) cm. Pre cooling scores of Weight Discrimination Differential Threshold of the dominant leg in the subjects was 1.625 ± 1.179 kg compared with post cooling scores of the dominant leg 1.85 (± 1.91) kg. Pre cooling scores of single leg hop and crossed over hop test of the dominant leg in the subjects compared with post cooling scores of the dominant leg showed no significant differences and it was also noted that the weight discrimination ability (weight discrimination differential threshold) didn't show any significant difference. All the values are reported as mean ± SD. This study provides additional evidence that proprioceptive acuity in the hamstring muscles (biceps femoris) remains largely unaffected after ice application to the hamstrings tendon (biceps femoris).
Using squat repetition maximum testing to determine hamstring resistance training exercise loads.
Ebben, William P; Long, Nicholas J; Pawlowski, Zach D; Chmielewski, Lauren M; Clewien, Rustin W; Jensen, Randall L
2010-02-01
The purpose of this study was to determine whether there is a linear relationship between the squat and a variety of hamstring resistance training exercises, and whether this relationship differs on the basis of sex. This study also sought to create prediction equations for the determination of hamstring exercise load based on the squat load. Repetition maximums of the squat, as well as 4 common hamstring resistance training exercises including the seated leg curl, stiff leg dead lift, single leg dead lift, and good morning exercise, were determined for each subject. Subjects included 21 men and 13 women collegiate athletes. Data were evaluated using linear regression analysis to predict hamstring exercise loads from 6 repetition maximum squat data. Results of the analysis of all subjects indicated that squat load was a significant predictor of loads for each of the hamstring exercises. However, separate analysis of women revealed that squat load was not a significant predictor of loads for any of the hamstring exercises. Analysis of the men revealed that squat was a significant predictor of load for the seated leg curl (R = 0.58, p < 0.001), stiff leg dead lift (R = 0.82, p < 0.001), single leg stiff leg dead lift (R = 0.80, p < 0.001), and good morning (R = 0.79, p < 0.001) exercises. On the basis of the analysis of the men, the following prediction equations were devised for each exercise: (1) seated leg curl load = squat load (0.186) + 10.935 kg, (2) stiff leg deadlift load = squat load (1.133) - 86.331 kg, (3) single leg stiff leg deadlift load = squat load (0.443) - 3.425 kg, and (4) good morning load = squat load (0.961) - 105.505 kg. Thus, results from testing core exercises such as the squat can provide useful data for the assignment of loads for assistance exercises.
Compliant walking appears metabolically advantageous at extreme step lengths.
Kim, Jaehoon; Bertram, John E A
2018-05-19
Humans alter gait in response to unusual gait circumstances to accomplish the task of walking. For instance, subjects spontaneously increase leg compliance at a step length threshold as step length increases. Here we test the hypothesis that this transition occurs based on the level of energy expenditure, where compliant walking becomes less energetically demanding at long step lengths. To map and compare the metabolic cost of normal and compliant walking as step length increases. 10 healthy individuals walked on a treadmill using progressively increasing step lengths (100%, 120%, 140% and 160% of preferred step length), in both normal and compliant leg walking as energy expenditure was recorded via indirect calorimetry. Leg compliance was controlled by lowering the center-of-mass trajectory during stance, forcing the leg to flex and extend as the body moved over the foot contact. For normal step lengths, compliant leg walking was more costly than normal walking gait, but compliant leg walking energetic cost did not increase as rapidly for longer step lengths. This led to an intersection between normal and compliant walking cost curves at 114% relative step length (regression analysis; r 2 = 0.92 for normal walking; r 2 = 0.65 for compliant walking). Compliant leg walking is less energetically demanding at longer step lengths where a spontaneous shift to compliant walking has been observed, suggesting the human motor control system is sensitive to energetic requirements and will employ alternate movement patterns if advantageous strategies are available. The transition could be attributed to the interplay between (i) leg work controlling body travel during single stance and (ii) leg work to control energy loss in the step-to-step transition. Compliant leg walking requires more stance leg work at normal step lengths, but involves less energy loss at the step-to-step transition for very long steps. Copyright © 2018 Elsevier B.V. All rights reserved.
Seymour, Ron; Engbretson, Brenda; Kott, Karen; Ordway, Nathaniel; Brooks, Gary; Crannell, Jessica; Hickernell, Elise; Wheeler, Katie
2007-03-01
This study investigated energy expenditure and obstacle course negotiation between the C-leg and various non-microprocessor control (NMC) prosthetic knees and compared a quality of life survey (SF-36v2) of use of the C-leg to national norms. Thirteen subjects with unilateral limb loss (12 with trans-femoral and one with a knee disarticulation amputation) participated in the study. The mean age was 46 years, range 30-75. Energy expenditure using both the NMC and C-leg prostheses was measured at self-selected typical and fast walking paces on a motorized treadmill. Subjects were also asked to walk through a standardized walking obstacle course carrying a 4.5 kg (10 lb) basket and with hands free. Finally, the SF-36v2 was completed for subjects while using the C-leg. Statistically significant differences were found in oxygen consumption between prostheses at both typical and fast paces with the C-leg showing decreased values. Use of the C-leg resulted in a statistically significant decrease in the number of steps and time to complete the obstacle course. Scores on a quality of life index for subjects using the C-leg were above the mean for norms for limitation in the use of an arm or leg, equal to the mean for the general United States population for the physical component score and were above this mean for the mental component score. Based on oxygen consumption and obstacle course findings, the C-leg when compared to the NMC prostheses may provide increased functional mobility and ease of performance in the home and community environment. Questionnaire results suggest a minimal quality of life impairment when using a C-leg for this cohort of individuals with amputation.
Seppecher, P.
2015-01-01
In order to found continuum mechanics, two different postulations have been used. The first, introduced by Lagrange and Piola, starts by postulating how the work expended by internal interactions in a body depends on the virtual velocity field and its gradients. Then, by using the divergence theorem, a representation theorem is found for the volume and contact interactions which can be exerted at the boundary of the considered body. This method assumes an a priori notion of internal work, regards stress tensors as dual of virtual displacements and their gradients, deduces the concept of contact interactions and produces their representation in terms of stresses using integration by parts. The second method, conceived by Cauchy and based on the celebrated tetrahedron argument, starts by postulating the type of contact interactions which can be exerted on the boundary of every (suitably) regular part of a body. Then it proceeds by proving the existence of stress tensors from a balance-type postulate. In this paper, we review some relevant literature on the subject, discussing how the two postulations can be reconciled in the case of higher gradient theories. Finally, we underline the importance of the concept of contact surface, edge and wedge s-order forces. PMID:26730215
Houldin, Adina; Chua, Romeo; Carpenter, Mark G; Lam, Tania
2012-08-01
Several studies have demonstrated that motor adaptations to a novel task environment can be transferred between limbs. Such interlimb transfer of motor commands is consistent with the notion of centrally driven strategies that can be generalized across different frames of reference. So far, studies of interlimb transfer of locomotor adaptations have yielded disparate results. Here we sought to determine whether locomotor adaptations in one (trained) leg show transfer to the other (test) leg during a unipedal walking task. We hypothesized that adaptation in the test leg to a velocity-dependent force field previously experienced by the trained leg will be faster, as revealed by faster recovery of kinematic errors and earlier onset of aftereffects. Twenty able-bodied adults walked unipedally in the Lokomat robotic gait orthosis, which applied velocity-dependent resistance to the legs. The amount of resistance was scaled to 10% of each individual's maximum voluntary contraction of the hip flexors. Electromyography and kinematics of the lower limb were recorded. All subjects were right-leg dominant and were tested for transfer of motor adaptations from the right leg to the left leg. Catch trials, consisting of unexpected removal of resistance, were presented after the first step with resistance and after a period of adaptation to test for aftereffects. We found no significant differences in the sizes of the aftereffects between the two legs, except for peak hip flexion during swing, or in the rate at which peak hip flexion adapted during steps against resistance between the two legs. Our results indicate that interlimb transfer of these types of locomotor adaptation is not a robust phenomenon. These findings add to our current understanding of motor adaptations and provide further evidence that generalization of adaptations may be dependent on the movement task.
Gardner, Andrew W; Montgomery, Polly S; Afaq, Azhar
2007-07-01
This study compared the exercise performance of patients with peripheral arterial disease (PAD) who have different types of exertional leg pain. Patients with PAD were classified into one of four groups according to the San Diego Claudication Questionnaire: intermittent claudication (n = 406), atypical exertional leg pain causing patients to stop (n = 125), atypical exertional leg pain in which patients were able to continue walking (n = 81), and leg pain on exertion and rest (n = 103). Patients were assessed on the primary outcome measures of ankle-brachial index (ABI), treadmill exercise measures, and ischemic window. All patients experienced leg pain consistent with intermittent claudication during a standardized treadmill test. The mean (+/- SD) initial claudication distance (ICD) was similar (P = .642) among patients with intermittent claudication (168 +/- 160 meters), atypical exertional leg pain causing patients to stop (157 +/- 130 meters), atypical exertional leg pain in which patients were able to continue walking (180 +/- 149 meters), and leg pain on exertion and rest (151 +/- 136 meters). The absolute claudication distance (ACD) was similar (P = .648) in the four respective groups (382 +/- 232, 378 +/- 237, 400 +/- 245, and 369 +/- 236 meters). Similarly, the ischemic window, expressed as the area under the curve (AUC) after treadmill exercise, was similar (P = .863) in these groups (189 +/- 137, 208 +/- 183, 193 +/- 143, and 199 +/- 119 AUC). PAD patients with different types of exertional leg pain, all limited by intermittent claudication during a standardized treadmill test, were remarkably similar in ICD, ACD, and ischemic window. Thus, the presence of ambulatory symptoms should be of primary clinical concern in evaluating PAD patients regardless of whether they are consistent with classic intermittent claudication.
Goerger, Benjamin M; Marshall, Stephen W; Beutler, Anthony I; Blackburn, J Troy; Wilckens, John H; Padua, Darin A
2015-02-01
Information as to how anterior cruciate ligament (ACL) injury and reconstructive surgery (ACLR) alter lower extremity biomechanics may improve rehabilitation and return to play guidelines, reducing the risk for repeat ACL injury. To compare lower extremity biomechanics before ACL injury and after subsequent ACLR for the injured and uninjured leg. Baseline unilateral lower extremity biomechanics were collected on the dominant leg of participants without ACL injury when they entered the Joint Undertaking to Monitor and Prevent ACL (JUMP-ACL) study. Thirty-one participants with subsequent ACL injury, reconstructive surgery and full return to physical activity completed repeat, follow-up biomechanical testing, as did 39 uninjured, matched controls. Not all injured participants suffered injury to the dominant leg, requiring separation of those with ACL injury into two groups: ACLR-injured leg group (n=12) and ACLR-uninjured leg group (n=19). We compared the landing biomechanics of these three groups (ACLR-injured leg, ACLR-uninjured leg, control) before ACL injury (baseline) with biomechanics after ACL injury, surgery and return to physical activity (follow-up). ACL injury and ACLR altered lower extremity biomechanics, as both ACLR groups demonstrated increases in frontal plane movement (increased hip adduction and knee valgus). The ACLR-injured leg group also exhibited decreased sagittal plane loading (decreased anterior tibial shear force, knee extension moment and hip flexion moment). No high-risk biomechanical changes were observed in control group participants. ACL injury and ACLR caused movement pattern alterations of the injured and uninjured leg that have previously shown to increase the risk for future non-contact ACL injury. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The crossed leg sign indicates a favorable outcome after severe stroke
Rémi, J.; Pfefferkorn, T.; Owens, R.L.; Schankin, C.; Dehning, S.; Birnbaum, T.; Bender, A.; Klein, M.; Adamec, J.; Pfister, H.-W.; Straube, A.
2011-01-01
Objective: We investigated whether crossed legs are a prognostic marker in patients with severe stroke. Methods: In this controlled prospective observational study, we observed patients with severe stroke who crossed their legs during their hospital stay and matched them with randomly selected severe stroke patients who did not cross their legs. The patients were evaluated upon admission, on the day of leg crossing, upon discharge, and at 1 year after discharge. The Glasgow Coma Scale, the NIH Stroke Scale (NIHSS), the modified Rankin Scale (mRS), and the Barthel Index (BI) were obtained. Results: Patients who crossed their legs (n = 34) and matched controls (n = 34) did not differ in any scale upon admission. At the time of discharge, the GCS did not differ, but the NIHSS was better in crossed legs patients (6.5 vs 10.6; p = 0.0026), as was the mRS (3.4 vs 5.1, p < 0.001), and the BI (34.0 vs 21.1; p = 0.0073). At 1-year follow-up, mRS (2.9 vs 5.1, p < 0.001) and the BI (71.3 vs 49.2; p = 0.045) were also better in the crossed leg group. The mortality between the groups differed grossly; only 1 patient died in the crossing group compared to 18 in the noncrossing group (p < 0.001). Conclusion: Leg crossing is an easily obtained clinical sign and is independent of additional technical examinations. Leg crossing within the first 15 days after severe stroke indicates a favorable outcome which includes less neurologic deficits, better independence in daily life, and lower rates of death. PMID:21987641
Kirschner, A K T; Rameder, A; Schrammel, B; Indra, A; Farnleitner, A H; Sommer, R
2012-06-01
Open cooling towers are frequent sources of infections with Legionella pneumophila. The gold standard for the detection of Leg. pneumophila is based on cultivation lasting up to 10 days and detecting only culturable cells. Alternative fluorescence in situ hybridization (FISH) protocols have been proposed, but they result in faint fluorescence signals and lack specificity because of cross-hybridization with other Legionella species. Our aim was thus to develop a new FISH protocol for rapid and specific detection of Leg. pneumophila in water samples. A novel catalysed reporter deposition FISH (CARD-FISH) protocol for the detection of Leg. pneumophila was developed, which significantly enhanced signal intensity as well as specificity of the probe through the use of a novel competitor probe. The developed protocol was compared with the culture method for monitoring the seasonal development of culturable and nonculturable Leg. pneumophila in two hospital cooling tower systems. Seasonal fluctuations of Leg. pneumophila concentrations detected via CARD-FISH were related to the development of the total bacterial community in both cooling towers, with temperature and biocide as the main factors controlling this development. Our results clearly showed that the majority of the Leg. pneumophila cells were in a nonculturable state. Thus, detection of Leg. pneumophila with culture methods may underestimate the total numbers of Leg. pneumophila present. Rapid, sensitive and specific detection and quantification of Leg. pneumophila in water systems is prerequisite for reliable risk estimation. The new protocol significantly improves current methodology and can be used to monitor and screen for Leg. pneumophila concentrations in cooling towers or other water systems. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Figueroa, Arturo; Kalfon, Roy; Madzima, Takudzwa A; Wong, Alexei
2014-02-01
The purpose of this study was to examine the impact of whole-body vibration (WBV) exercise training on arterial stiffness (pulse wave velocity [PWV]), blood pressure (BP), and leg muscle function in postmenopausal women. Twenty-five postmenopausal women with prehypertension and hypertension (mean [SE]; age, 56 [1] y; systolic BP, 139 [2] mm Hg; body mass index, 34.7 [0.8] kg/m2) were randomized to 12 weeks of WBV exercise training (n = 13) or to the no-exercise control group. Systolic BP, diastolic BP, mean arterial pressure, heart rate, carotid-femoral PWV, brachial-ankle PWV, femoral-ankle PWV (legPWV), leg lean mass, and leg muscle strength were measured before and after 12 weeks. There was a group-by-time interaction (P < 0.05) for arterial stiffness, BP, and strength as brachial-ankle PWV (-1.3 [0.3] m/s, P < 0.01), legPWV (-0.81 [0.22] m/s, P < 0.01), systolic BP (-12 [3] mm Hg, P < 0.01), diastolic BP (-6 [2] mm Hg, P < 0.01), and mean arterial pressure (-9 [3] mm Hg, P < 0.01) decreased and as strength increased (21.0% [2.2%], P < 0.001) after WBV exercise training compared with no change after control. Heart rate decreased (-3 [1] beats/min, P < 0.05) after WBV exercise training, but there was no interaction (P > 0.05). Leg lean mass and carotid-femoral PWV were not significantly (P > 0.05) affected by WBV exercise training or control. Our findings indicate that WBV exercise training improves systemic and leg arterial stiffness, BP, and leg muscle strength in postmenopausal women with prehypertension or hypertension. WBV exercise training may decrease cardiovascular and disability risks in postmenopausal women by reducing legPWV and increasing leg muscle strength.
Trans-tibial amputee gait: time-distance parameters and EMG activity.
Isakov, E; Keren, O; Benjuya, N
2000-12-01
Gait analysis of trans-tibial (TT) amputees discloses asymmetries in gait parameters between the amputated and sound legs. The present study aimed at outlining differences between both legs with regard to kinematic parameters and activity of the muscles controlling the knees. The gait of 14 traumatic TT amputees, walking at a mean speed of 74.96 m/min, was analysed by means of an electronic walkway, video camera, and portable electromyography system. Results showed differences in kinematic parameters. Step length, step time and swing time were significantly longer, while stance time and single support time were significantly shorter on the amputated side. A significant difference was also found between knee angle in both legs at heel strike. The biceps femoris/vastus medialis ratio in the amputated leg, during the first half of stance phase, was significantly higher when compared to the same muscle ratio in the sound leg. This difference was due to the higher activity of the biceps femoris, almost four times higher than the vastus medialis in the amputated leg. The observed differences in time-distance parameters are due to stiffness of the prosthesis ankle (the SACH foot) that impedes the normal forward advance of the amputated leg during the first half of stance. The higher knee flexion at heel strike is due to the necessary socket alignment. Unlike in the sound leg, the biceps femoris in the amputated leg reaches maximal activity during the first half of stance, cocontracting with the vastus medialis, to support body weight on the amputated leg. The obtained data can serve as a future reference for evaluating the influence of new prosthetic components on the quality of TT amputee's gait.
Kwak, Bokeon; Bae, Joonbum
2017-05-22
The locomotion of water beetles has been widely studied in biology owing to their remarkable swimming skills. Inspired by the oar-like legs of water beetles, designing a robot that swims under the principle of drag-powered propulsion can lead to highly agile mobility. But its motion can easily be discontinuous and jerky due to backward motions (i.e. retraction) of the legs. Here we proposed novel hair-like appendages and consider their coordination to achieve steady and efficient swimming on the water surface. First of all, we propose several design schemes and fabrication methods of the hair-like appendages, which can passively adjust their projected area while obtaining enough thrust. The coordination between the two pairs of legs, as with water beetles in nature, were also investigated to achieve steady swimming without backward movement by varying the beating frequency and phase of the legs. To verify the functionality of the hair-like appendages and their coordinations, six different types of appendages were fabricated, and two robots (one with a single pair of legs and the other with two pairs of legs) were built. Locomotion of the robots was extensively compared through experiments, and it was found that steady swimming was achieved by properly coordinating the two pairs of legs without sacrificing their speed. Also, owing to the lower velocity fluctuation during swimming, it was shown that using two pairs of legs was more energy efficient than the robot with single pair of legs.
Lower extremity control during turns initiated with and without hip external rotation.
Zaferiou, Antonia M; Flashner, Henryk; Wilcox, Rand R; McNitt-Gray, Jill L
2017-02-08
The pirouette turn is often initiated in neutral and externally rotated hip positions by dancers. This provides an opportunity to investigate how dancers satisfy the same mechanical objectives at the whole-body level when using different leg kinematics. The purpose of this study was to compare lower extremity control strategies during the turn initiation phase of pirouettes performed with and without hip external rotation. Skilled dancers (n=5) performed pirouette turns with and without hip external rotation. Joint kinetics during turn initiation were determined for both legs using ground reaction forces (GRFs) and segment kinematics. Hip muscle activations were monitored using electromyography. Using probability-based statistical methods, variables were compared across turn conditions as a group and within-dancer. Despite differences in GRFs and impulse generation between turn conditions, at least 90% of each GRF was aligned with the respective leg plane. A majority of the net joint moments at the ankle, knee, and hip acted about an axis perpendicular to the leg plane. However, differences in shank alignment relative to the leg plane affected the distribution of the knee net joint moment when represented with respect to the shank versus the thigh. During the initiation of both turns, most participants used ankle plantar flexor moments, knee extensor moments, flexor and abductor moments at the push leg׳s hip, and extensor and abductor moments at the turn leg׳s hip. Representation of joint kinetics using multiple reference systems assisted in understanding control priorities. Copyright © 2017 Elsevier Ltd. All rights reserved.
ODYSSEUS autonomous walking robot: The leg/arm design
NASA Technical Reports Server (NTRS)
Bourbakis, N. G.; Maas, M.; Tascillo, A.; Vandewinckel, C.
1994-01-01
ODYSSEUS is an autonomous walking robot, which makes use of three wheels and three legs for its movement in the free navigation space. More specifically, it makes use of its autonomous wheels to move around in an environment where the surface is smooth and not uneven. However, in the case that there are small height obstacles, stairs, or small height unevenness in the navigation environment, the robot makes use of both wheels and legs to travel efficiently. In this paper we present the detailed hardware design and the simulated behavior of the extended leg/arm part of the robot, since it plays a very significant role in the robot actions (movements, selection of objects, etc.). In particular, the leg/arm consists of three major parts: The first part is a pipe attached to the robot base with a flexible 3-D joint. This pipe has a rotated bar as an extended part, which terminates in a 3-D flexible joint. The second part of the leg/arm is also a pipe similar to the first. The extended bar of the second part ends at a 2-D joint. The last part of the leg/arm is a clip-hand. It is used for selecting several small weight and size objects, and when it is in a 'closed' mode, it is used as a supporting part of the robot leg. The entire leg/arm part is controlled and synchronized by a microcontroller (68CH11) attached to the robot base.
Leg injuries and wound repair among cosmetid harvestmen (Arachnida, Opiliones, Laniatores).
Townsend, Victor R; Schaus, Maynard H; Zvonareva, Tatyana; Illinik, Jeffrey J; Evans, John T
2017-01-01
Previous studies of leg injuries in harvestmen have focused on the fitness consequences for individuals that use autospasy (voluntary detachment of the leg) as a secondary defense mechanism. Leg damage among non-autotomizing species of laniatorean harvestmen has not been investigated. Under laboratory conditions, we damaged femur IV of Cynorta marginalis and observed with scanning electron microscopy (SEM) the changes in these wounds over ten days. We also used SEM to examine leg damage from individuals of three species of cosmetid harvestmen that were collected in the field. On the basis of changes in the external surface of the hemolymph coagulum, we classified these wounds as fresh (coagulum forming), recent (coagulum with smooth surface), older (coagulum is scale-like with visible cell fragments), and fully healed (scale replaced by new cuticle growth on the terminal stump). Our observations indicate that wound healing in harvestmen occurs in a manner comparable to that of other chelicerates. Leg injuries exhibited interspecific variation with respect to the overall frequency of leg wounds and the specific legs that were most commonly damaged. In addition, we measured walking and climbing speeds of adult C. marginalis and found that individuals with fresh injuries (lab-induced) to femur IV walked at speeds significantly slower than uninjured adults or individuals collected from the field that had fully healed wounds to a single leg. J. Morphol. 278:73-88, 2017. ©© 2016 Wiley Periodicals,Inc. © 2016 Wiley Periodicals, Inc.
Self-referenced locking of optical coherence by single-detector electronic-frequency tagging
NASA Astrophysics Data System (ADS)
Shay, T. M.; Benham, Vincent; Spring, Justin; Ward, Benjamin; Ghebremichael, F.; Culpepper, Mark A.; Sanchez, Anthony D.; Baker, J. T.; Pilkington, D.; Berdine, Richard
2006-02-01
We report a novel coherent beam combining technique. This is the first actively phase locked optical fiber array that eliminates the need for a separate reference beam. In addition, only a single photodetector is required. The far-field central spot of the array is imaged onto the photodetector to produce the phase control loop signals. Each leg of the fiber array is phase modulated with a separate RF frequency, thus tagging the optical phase shift for each leg by a separate RF frequency. The optical phase errors for the individual array legs are separated in the electronic domain. In contrast with the previous active phase locking techniques, in our system the reference beam is spatially overlapped with all the RF modulated fiber leg beams onto a single detector. The phase shift between the optical wave in the reference leg and in the RF modulated legs is measured separately in the electronic domain and the phase error signal is feedback to the LiNbO 3 phase modulator for that leg to minimize the phase error for that leg relative to the reference leg. The advantages of this technique are 1) the elimination of the reference beam and beam combination optics and 2) the electronic separation of the phase error signals without any degradation of the phase locking accuracy. We will present the first theoretical model for self-referenced LOCSET and describe experimental results for a 3 x 3 array.
Kinematic primitives for walking and trotting gaits of a quadruped robot with compliant legs.
Spröwitz, Alexander T; Ajallooeian, Mostafa; Tuleu, Alexandre; Ijspeert, Auke Jan
2014-01-01
In this work we research the role of body dynamics in the complexity of kinematic patterns in a quadruped robot with compliant legs. Two gait patterns, lateral sequence walk and trot, along with leg length control patterns of different complexity were implemented in a modular, feed-forward locomotion controller. The controller was tested on a small, quadruped robot with compliant, segmented leg design, and led to self-stable and self-stabilizing robot locomotion. In-air stepping and on-ground locomotion leg kinematics were recorded, and the number and shapes of motion primitives accounting for 95% of the variance of kinematic leg data were extracted. This revealed that kinematic patterns resulting from feed-forward control had a lower complexity (in-air stepping, 2-3 primitives) than kinematic patterns from on-ground locomotion (νm4 primitives), although both experiments applied identical motor patterns. The complexity of on-ground kinematic patterns had increased, through ground contact and mechanical entrainment. The complexity of observed kinematic on-ground data matches those reported from level-ground locomotion data of legged animals. Results indicate that a very low complexity of modular, rhythmic, feed-forward motor control is sufficient for level-ground locomotion in combination with passive compliant legged hardware.
Static balance according to hip joint angle of unsupported leg during one-leg standing.
Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob
2017-05-01
[Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.
[Design and application of medical electric leg-raising machine].
Liang, Jintang; Chen, Jinyuan; Zhao, Zixian; Lin, Jinfeng; Li, Juanhong; Zhong, Jingliang
2017-08-01
Passive leg raising is widely used in clinic, but it lacks of specialized mechanical raise equipment. It requires medical staff to raise leg by hand or requires a multi-functional bed to raise leg, which takes time and effort. Therefore we have developed a new medical electric leg-raising machine. The equipment has the following characteristics: simple structure, stable performance, easy operation, fast and effective, safe and comfortable. The height range of the lifter is 50-120 cm, the range of the angle of raising leg is 10degree angle-80degree angle, the maximum supporting weight is 40 kg. Because of raising the height of the lower limbs and making precise angle, this equipment can completely replace the traditional manner of lifting leg by hand with multi-functional bed to lift patients' leg and can reduce the physical exhaustion and time consumption of medical staff. It can change the settings at any time to meet the needs of the patient; can be applied to the testing of PLR and dynamically assessing the hemodynamics; can prevent deep vein thrombosis and some related complications of staying in bed; and the machine is easy to be cleaned and disinfected, which can effectively avoid hospital acquired infection and cross infection; and can also be applied to emergency rescue of various disasters and emergencies.
A new biarticular actuator design facilitates control of leg function in BioBiped3.
Sharbafi, Maziar Ahmad; Rode, Christian; Kurowski, Stefan; Scholz, Dorian; Möckel, Rico; Radkhah, Katayon; Zhao, Guoping; Rashty, Aida Mohammadinejad; Stryk, Oskar von; Seyfarth, Andre
2016-07-01
Bioinspired legged locomotion comprises different aspects, such as (i) benefiting from reduced complexity control approaches as observed in humans/animals, (ii) combining embodiment with the controllers and (iii) reflecting neural control mechanisms. One of the most important lessons learned from nature is the significant role of compliance in simplifying control, enhancing energy efficiency and robustness against perturbations for legged locomotion. In this research, we investigate how body morphology in combination with actuator design may facilitate motor control of leg function. Inspired by the human leg muscular system, we show that biarticular muscles have a key role in balancing the upper body, joint coordination and swing leg control. Appropriate adjustment of biarticular spring rest length and stiffness can simplify the control and also reduce energy consumption. In order to test these findings, the BioBiped3 robot was developed as a new version of BioBiped series of biologically inspired, compliant musculoskeletal robots. In this robot, three-segmented legs actuated by mono- and biarticular series elastic actuators mimic the nine major human leg muscle groups. With the new biarticular actuators in BioBiped3, novel simplified control concepts for postural balance and for joint coordination in rebounding movements (drop jumps) were demonstrated and approved.
Kinematic primitives for walking and trotting gaits of a quadruped robot with compliant legs
Spröwitz, Alexander T.; Ajallooeian, Mostafa; Tuleu, Alexandre; Ijspeert, Auke Jan
2014-01-01
In this work we research the role of body dynamics in the complexity of kinematic patterns in a quadruped robot with compliant legs. Two gait patterns, lateral sequence walk and trot, along with leg length control patterns of different complexity were implemented in a modular, feed-forward locomotion controller. The controller was tested on a small, quadruped robot with compliant, segmented leg design, and led to self-stable and self-stabilizing robot locomotion. In-air stepping and on-ground locomotion leg kinematics were recorded, and the number and shapes of motion primitives accounting for 95% of the variance of kinematic leg data were extracted. This revealed that kinematic patterns resulting from feed-forward control had a lower complexity (in-air stepping, 2–3 primitives) than kinematic patterns from on-ground locomotion (νm4 primitives), although both experiments applied identical motor patterns. The complexity of on-ground kinematic patterns had increased, through ground contact and mechanical entrainment. The complexity of observed kinematic on-ground data matches those reported from level-ground locomotion data of legged animals. Results indicate that a very low complexity of modular, rhythmic, feed-forward motor control is sufficient for level-ground locomotion in combination with passive compliant legged hardware. PMID:24639645
Towards active capsular endoscopy: preliminary results on a legged platform.
Menciassi, Arianna; Stefanini, Cesare; Orlandi, Giovanni; Quirini, Marco; Dario, Paolo
2006-01-01
This paper illustrates the problem of active locomotion in the gastrointestinal tract for endoscopic capsules. Authors analyze the problem of locomotion in unstructured, flexible and tubular environments and explain the reasons leading to the selection of a legged system. They present a theoretical simulation of legged capsule locomotion, which is used to define the optimal parameters for capsule design and gait selection. Finally, a legged capsule--about 3 cm3 in volume--is presented; it consists of 4 back legs whose actuation is achieved thanks to a miniaturized DC brushless motor. In vitro tests demonstrate good performance in terms of achievable speed (92 mm/min).
Perception, planning, and control for walking on rugged terrain
NASA Technical Reports Server (NTRS)
Simmons, Reid; Krotkov, Eric
1991-01-01
The CMU Planetary Rover project is developing a six-legged walking robot capable of autonomously navigating, exploring, and acquiring samples in rugged, unknown environments. To gain experience with the problems involved in walking on rugged terrain, a full-scale prototype leg was built and mounted on a carriage that rolls along overhead rails. Issues addressed in developing the software system to autonomously walk the leg through rugged terrain are described. In particular, the insights gained into perceiving and modeling rugged terrain, controlling the legged mechanism, interacting with the ground, choosing safe yet effective footfalls, and planning efficient leg moves through space are described.
Seward, Austin C; Meara, Daniel J
2013-07-01
Silicone and other fillers have become a popular aid to increase soft tissue density, decrease static skin rhytids, and treat muscle wasting, particularly in the face. As a result, injectable silicone has become popular in patients with the human immunodeficiency virus (HIV). It has been postulated that highly active antiretroviral therapy detrimentally induces the physiologic process of fat atrophy of the temporal and buccal fat pads of the face and regional fat wasting of the arms, legs, and buttocks and that HIV protease inhibitors may induce fat atrophy by binding and inhibiting homologous human proteins that are involved in fat metabolism. The classic hollowed-out facial appearance linked to HIV positivity can have detrimental social implications in infected patients who are otherwise very functional. In consequence, facial implantation, fat transplantation, and dermal and subcutaneous fillers have been used to aid in the restoration of facial appearance. This report describes the case of a patient who underwent multiple rounds of silicone injections and complained of intermittent facial swelling and pain long after the injections. The authors report on the safety of specific medical-grade injectable fillers and techniques found to be safely effective, especially in the HIV-positive population. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
De Andrade, Paula B. M.; Neff, Laurence A.; Strosova, Miriam K.; Arsenijevic, Denis; Patthey-Vuadens, Ophélie; Scapozza, Leonardo; Montani, Jean-Pierre; Ruegg, Urs T.; Dulloo, Abdul G.; Dorchies, Olivier M.
2015-01-01
Weight regain after caloric restriction results in accelerated fat storage in adipose tissue. This catch-up fat phenomenon is postulated to result partly from suppressed skeletal muscle thermogenesis, but the underlying mechanisms are elusive. We investigated whether the reduced rate of skeletal muscle contraction-relaxation cycle that occurs after caloric restriction persists during weight recovery and could contribute to catch-up fat. Using a rat model of semistarvation-refeeding, in which fat recovery is driven by suppressed thermogenesis, we show that contraction and relaxation of leg muscles are slower after both semistarvation and refeeding. These effects are associated with (i) higher expression of muscle deiodinase type 3 (DIO3), which inactivates tri-iodothyronine (T3), and lower expression of T3-activating enzyme, deiodinase type 2 (DIO2), (ii) slower net formation of T3 from its T4 precursor in muscles, and (iii) accumulation of slow fibers at the expense of fast fibers. These semistarvation-induced changes persisted during recovery and correlated with impaired expression of transcription factors involved in slow-twitch muscle development. We conclude that diminished muscle thermogenesis following caloric restriction results from reduced muscle T3 levels, alteration in muscle-specific transcription factors, and fast-to-slow fiber shift causing slower contractility. These energy-sparing effects persist during weight recovery and contribute to catch-up fat. PMID:26441673
White, L H; Bradley, T D; Logan, A G
2015-06-01
Obstructive sleep apnoea (OSA) is highly prevalent in hypertensive patients, particularly those with drug resistance. Evidence from animal experiments, epidemiologic studies and clinical trials strongly suggest a causal link. Mechanistic studies argue for increased sympathetic neural activity and endothelial dysfunction. However, disturbances in fluid volume regulation and distribution may also be involved in the pathogenesis of these two conditions. Several studies have shown a high prevalence of OSA in fluid-retaining states including hypertension, a direct relationship between the severity of OSA and the volume of fluid displaced from the legs to the neck during sleep, and a decrease in upper airway cross-sectional area in response to graded lower body positive pressure. Treatments targeting fluid retention and redistribution, including diuretics, mineralocorticoid antagonists, exercise, and possibly renal denervation lower blood pressure and reduce the apnoea-hypopnoea index, a measure of OSA severity. From these observations, it has been postulated that during the daytime, excess fluid collects in the lower extremities due to gravity, and on lying down overnight is redistributed rostrally to the neck, where it may narrow the upper airway and increase its collapsibility, predisposing to OSA when pharyngeal dilator muscle activity decreases during sleep. This article discusses the associations between OSA and hypertension and reviews the evidence for fluid accumulation and its nocturnal rostral redistribution in the pathogenesis of OSA in hypertensive patients.
... Legs Syndrome Condition Restless Legs Syndrome Share Print Table of Contents1. Overview2. Symptoms3. Diagnosis4. Treatment5. Questions Overview ... twitch when you try and sleep (also called periodic limb movements of sleep or PLMS). Diagnosis How ...
The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...
Design of Force Sensor Leg for a Rocket Thrust Detector
NASA Astrophysics Data System (ADS)
Woten, Douglas; McGehee, Tripp; Wright, Anne
2005-03-01
A hybrid rocket is composed of a solid fuel and a separate liquid or gaseous oxidizer. These rockets may be throttled like liquid rockets, are safer than solid rockets, and are much less complex than liquid rockets. However, hybrid rockets produce thrust oscillations that are not practical for large scale use. A lab scale hybrid rocket at the University of Arkansas at Little Rock (UALR) Hybrid Rocket Facility is used to develop sensors to measure physical properties of hybrid rockets. Research is currently being conducted to design a six degree of freedom force sensor to measure the thrust and torque in all three spacial dimensions. The detector design uses six force sensor legs. Each leg utilizes strain gauges and a Wheatstone bridge to produce a voltage propotional to the force on the leg. The leg was designed using the CAD software ProEngineer and ProMechanica. Computer models of the strains on the single leg will be presented. A prototype leg was built and was tested in an INSTRON and results will be presented.
Rodríguez-Lorenzo, Lois; Fernandez-del-Olmo, Miguel; Sanchez-Molina, José Andrés
2016-01-01
Abstract Kicking is one of the most important skills in soccer and the ability to achieve ma ximal kicking velocity with both legs leads to an advantage for the soccer player. This study examined the relationship be tween kicking ball velocity with both legs using anthropometric measurements and vertical jumps (a squat jump (SJ); a countermovement jump without (CMJ) and with the arm swing (CMJA) and a reactive jump (RJ)). Anthropome tric measurements did not correlate with kicking ball velocity. Vertical jumps correlated significantly with kicking ball velocity using the dominant leg only (r = .47, r = .58, r = .44, r = .51, for SJ, CMJ, CMJA and RJ, respectively) . Maximal kicking velocity with the dominant leg was significantly higher than with the non-dominant leg (t = 18.0 4, p < 0.001). Our results suggest that vertical jumps may be an optimal test to assess neuromuscular skills involved in kicking at maximal speed. Lack of the relationship between vertical jumps and kicking velocity with the non-dominant leg may reflect a difficulty to exhibit the neuromuscular skills during dominant leg kicking. PMID:28149419
Bando, Tetsuya; Ishimaru, Yoshiyasu; Kida, Takuro; Hamada, Yoshimasa; Matsuoka, Yuji; Nakamura, Taro; Ohuchi, Hideyo; Noji, Sumihare; Mito, Taro
2013-03-01
In the cricket Gryllus bimaculatus, missing distal parts of the amputated leg are regenerated from the blastema, a population of dedifferentiated proliferating cells that forms at the distal tip of the leg stump. To identify molecules involved in blastema formation, comparative transcriptome analysis was performed between regenerating and normal unamputated legs. Components of JAK/STAT signalling were upregulated more than twofold in regenerating legs. To verify their involvement, Gryllus homologues of the interleukin receptor Domeless (Gb'dome), the Janus kinase Hopscotch (Gb'hop) and the transcription factor STAT (Gb'Stat) were cloned, and RNAi was performed against these genes. Gb'dome(RNAi), Gb'hop(RNAi) and Gb'Stat(RNAi) crickets showed defects in leg regeneration. Blastema expression of Gb'cyclinE was decreased in the Gb'Stat(RNAi) cricket compared with that in the control. Hyperproliferation of blastema cells caused by Gb'fat(RNAi) or Gb'warts(RNAi) was suppressed by RNAi against Gb'Stat. The results suggest that JAK/STAT signalling regulates blastema cell proliferation during leg regeneration.
The effect of spinal manipulation on imbalances in leg strength.
Chilibeck, Philip D; Cornish, Stephen M; Schulte, Al; Jantz, Nathan; Magnus, Charlene R A; Schwanbeck, Shane; Juurlink, Bernhard H J
2011-09-01
We hypothesized that spinal manipulation (SM) would reduce strength imbalances between legs. Using an un-blinded randomized design, 28 males and 21 females (54 ± 19y) with at least a 15% difference in isometric strength between legs for hip flexion, extension, abduction, or knee flexion were randomized to treatment or placebo (mock spinal manipulation). Strength of the stronger and weaker legs for hip flexion, extension, abduction, and/or knee flexion was assessed before and after the intervention. SM reduced the relative strength difference between legs for knee flexion (mean ± SD 57 ± 53 to 5 ± 14%) and hip flexion (24 ± 12 to 11 ± 15%) compared to placebo (34 ± 29 to 24 ± 36%, and 20 ± 18 to 22 ± 26%, respectively) (p = 0.05). SM also improved strength in the weak leg for hip abduction (104 ± 43 to 116 ± 43 Nm) compared to placebo (84 ± 24 to 85 ± 31 Nm) (p = 0.03). This study suggests that spinal manipulation may reduce imbalances in strength between legs for knee and hip flexion.
NASA Technical Reports Server (NTRS)
Williams, P.; Sagraniching, E.; Bennett, M.; Singh, R.
1991-01-01
A walking robot was designed, analyzed, and tested as an intelligent, mobile, and a terrain adaptive system. The robot's design was an application of existing technologies. The design of the six legs modified and combines well understood mechanisms and was optimized for performance, flexibility, and simplicity. The body design incorporated two tripods for walking stability and ease of turning. The electrical hardware design used modularity and distributed processing to drive the motors. The software design used feedback to coordinate the system and simple keystrokes to give commands. The walking machine can be easily adapted to hostile environments such as high radiation zones and alien terrain. The primary goal of the leg design was to create a leg capable of supporting a robot's body and electrical hardware while walking or performing desired tasks, namely those required for planetary exploration. The leg designers intent was to study the maximum amount of flexibility and maneuverability achievable by the simplest and lightest leg design. The main constraints for the leg design were leg kinematics, ease of assembly, degrees of freedom, number of motors, overall size, and weight.
The second leg home advantage: evidence from European football cup competitions.
Page, Lionel; Page, Katie
2007-12-01
The home advantage is a widely acknowledged sporting phenomenon, especially in association football. Here, we examine the second leg home advantage, an effect that is discussed in the public domain but which has received very little scientific attention. The second leg home advantage effect occurs when on average teams are more likely to win a two-stage knock-out competition when they play at home in the second leg. That is, both teams have a home advantage but this advantage is significantly greater for the team that plays at home second. Examining data from three different European Cup football competitions spanning 51 years, we show that the second leg home advantage is a real phenomenon. The second leg home team has more than a 50% probability to qualify for the next round in the competition even after controlling for extra time and team ability as possible alternative explanations. The second leg home advantage appears, however, to have decreased significantly over the past decade. Possible reasons for its existence and subsequent decline are presented.
Wollina, Uwe; Heinig, Birgit; Stelzner, Christian; Hansel, Gesina; Schönlebe, Jacqueline; Tchernev, Georgi; Lotti, Torello
2018-01-25
Leg ulcers are a burden to patients, their families and society. The second most common cause of chronic leg ulcers is the mixed arterio-venous type. An 80-year-old female patient presented to our department due to painful enlarging chronic leg ulcer of mixed arteriovenous origin on her left lower leg. She suffered from peripheral arterial occlusive disease stage I and chronic venous insufficiency Widmer grade IIIa, and a number of comorbidities. The aim of our ulcer treatment was a complete and stable wound closure that was hampered by arterial occlusion, exposed tendon, and renal insiffuciency. To improve the prognosis for ulcer surgery, we performed percutaneous transluminal angioplasty, transcutaneous CO 2 and deep ulcer shaving. The wound was closed by sandwich transplantation using elastin-collagen dermal template and meshed split skin graft. She had a 100% graft take with rapid reduction of severe wound pain. Complex approaches are necessary, to gain optimum results in leg ulcer therapy in mixed leg ulcers. Therapeutic nihilism should be abandonend.
Differentiated norepinephrine spillover in human skeletal muscle.
Karlsson, A K; Elam, M; Lönnroth, P; Sullivan, L; Friberg, P
1997-07-01
Most neurophysiological studies have shown similar sympathetic outflow to arm and leg. However, some direct microneurographic recordings indicate differentiated sympathetic outflow to limbs both at rest and during mental stress. Hence, differentiated levels of norepinephrine (NE) spillover could prevail. By steady-state infusion of [3H]NE and body composition determination by dual-energy X-ray absorptiometry-scan, we simultaneously assessed arm and leg NE spillover related to 100 g tissue and total limb weight. NE spillover was lower in leg than arm (0.26 vs. 1.51 pmol.min-1.100 g-1, P < 0.05), and the difference remained when expressed as a function of total limb weight (66 vs. 137 pmol/min, P < 0.05). Fractional extraction of [3H]NE was similar in arm and leg. Neuronal uptake blockade by desipramine was more effective in leg than arm; fractional extraction in leg decreased by 32% (P < 0.05) but was unaltered in arm. Thus a lower NE spillover was observed from leg than arm, possibly reflecting a lower sympathetic outflow and a more neuronally dependent reuptake.
Bergmann, J; Krewer, C; Müller, F; Koenig, A; Riener, R
2011-01-01
Virtual Reality (VR) provides a promising medium to enrich robot assisted rehabilitation. VR applications present the opportunity to engage patients in therapy and control participation. The aim of this study was to investigate two strategies to control active participation of a stroke patient focusing on the involvement of the paretic leg in task solution. A subacute stroke patient with a severe hemiparesis performed two experiments on the driven gait orthosis Lokomat. Patient activity was quantified by weighted interaction torques measured in both legs (experiment A) and the paretic leg only (experiment B). The patient was able to successfully implement both the bilateral and unilateral control modality. Both control modes increased the motor output of the paretic leg, however the paretic leg control mode resulted in a much more differentiated regulation of the activity in the leg. Both control modes are appropriate approaches to enhance active participation and increase motor output in the paretic leg. Further research should evaluate the therapeutic benefit of patients with hemiparesis using the unilateral control mode depending on the severity of their impairment. © 2011 IEEE
Energy absorption as a predictor of leg impedance in highly trained females.
Kulas, Anthony S; Schmitz, Randy J; Schultz, Sandra J; Watson, Mary Allen; Perrin, David H
2006-08-01
Although leg spring stiffness represents active muscular recruitment of the lower extremity during dynamic tasks such as hopping and running, the joint-specific characteristics comprising the damping portion of this measure, leg impedance, are uncertain. The purpose of this investigation was to assess the relationship between leg impedance and energy absorption at the ankle, knee, and hip during early (impact) and late (stabilization) phases of landing. Twenty highly trained female dancers (age = 20.3 +/- 1.4 years, height = 163.7 +/- 6.0 cm, mass = 62.1 +/- 8.1 kg) were instrumented for biomechanical analysis. Subjects performed three sets of double-leg landings from under preferred, stiff, and soft landing conditions. A stepwise linear regression analysis revealed that ankle and knee energy absorption at impact, and knee and hip energy absorption during the stabilization phases of landing explained 75.5% of the variance in leg impedance. The primary predictor of leg impedance was knee energy absorption during the stabilization phase, independently accounting for 55% of the variance. Future validation studies applying this regression model to other groups of individuals are warranted.
11. NORTH VIEW OF INNER FACING OF SOUTHEASTERN LEG OF ...
11. NORTH VIEW OF INNER FACING OF SOUTHEASTERN LEG OF SEA WALL. SOUTHERN END OF NORTHEASTERN LEG OF SEA WALL IN BACKGROUND. - Fort Delaware, Sea Wall, Pea Patch Island, Delaware City, New Castle County, DE
Towards a Comparative Measure of Legged Agility
2014-06-01
body movement with change of velocity or direction in response to a stimulus” [18]. Notwithstanding the many informative and inspiring studies of legged...specific power (watts per kilogram taken over a gait cycle of leg power output relative to leg muscle mass or body mass) [22, 26–28] but it is not scale...closest to the body mass normalized mea- sure we will introduce below. In contrast, characterizing directional aspects of agility performance seems
NASA Technical Reports Server (NTRS)
Vallet, M.
1982-01-01
The acoustical index leg was studied to determine its accuracy in predicting annoyance from traffic noise. Annoyance was tested in experimental situations where the frequency of the number of heavy vehicles varied from 3 to 30 HV/30 min for different classes of the Leg level at 50, 55, 60 dB(A) of traffic noise. The results showed that: (1) for a constant Leg level the annoyance increases as a function of the number of HV up to a certain threshold at which the annoyance is stabilized; (2) for a constant frequency of passage of HV, the annoyance increases with the Leg level; (3) composite indexes of the type Leg + Log NHV, L1 + EMER or L1 + L10 give a predictive value greater than that of the Leg pr Log nHV taken alone.
Blickhan, Reinhard; Seyfarth, Andre; Geyer, Hartmut; Grimmer, Sten; Wagner, Heiko; Günther, Michael
2007-01-15
Research on the biomechanics of animal and human locomotion provides insight into basic principles of locomotion and respective implications for construction and control. Nearly elastic operation of the leg is necessary to reproduce the basic dynamics in walking and running. Elastic leg operation can be modelled with a spring-mass model. This model can be used as a template with respect to both gaits in the construction and control of legged machines. With respect to the segmented leg, the humanoid arrangement saves energy and ensures structural stability. With the quasi-elastic operation the leg inherits the property of self-stability, i.e. the ability to stabilize a system in the presence of disturbances without sensing the disturbance or its direct effects. Self-stability can be conserved in the presence of musculature with its crucial damping property. To ensure secure foothold visco-elastic suspended muscles serve as shock absorbers. Experiments with technically implemented leg models, which explore some of these principles, are promising.
Rembrandt's 'Beggar with a wooden leg' and other comparable prints.
ten Kate, J J; Jennekens, F G I; Vos-Niël, J M E
2009-02-01
Rembrandt's etching of a beggar with a wooden leg is notable because the two lower limbs of the presumed beggar are present and not deformed. Using the facilities of four specialised Dutch art institutes, we carried out a systematic investigation to find other etchings and engravings of subjects with artificial legs supporting non-amputated limbs, from the period 1500 to 1700 AD. We discovered 28 prints produced by at least 18 artists. Several offered clues to a disorder of a knee, the lower leg or the foot. All individuals were adult males, suggesting the probability of traumatic lesions. We conclude that in this period artificial legs were not only used in the case of absence of part of a lower limb, but also for other reasons, notably disorders of the knee, lower leg or foot. They may also have been used to attract compassion.
Markham, Larry W; Knecht, Sandra K; Daniels, Stephen R; Mays, Wayne A; Khoury, Philip R; Knilans, Timothy K
2004-11-01
Often, the lack of systemic arterial hypertension and the lack of a resting arm-leg blood pressure gradient are used to assess the adequacy of the anatomic result after intervention for coarctation of the aorta (CoA). Some patients with no arm-leg gradient at rest may develop a gradient with exercise, leading caregivers to question the success of the repair. It is not clear what the prevalence is of patients who have undergone a successful intervention for CoA and have no arm-leg gradient at rest but develop a significant gradient with exercise and which factors may predict the development of an arm-leg gradient with exercise. This study evaluates the prevalence and predictors of an exercise-induced arm-leg gradient in subjects who have undergone an apparently successful intervention for CoA.
Injury due to leg bands in willow flycatchers
Sedgwick, J.A.; Klus, R.J.
1997-01-01
We report an apparently unusually high incidence of leg injury in Willow Flycatchers (Empidonax traillii) as a result of banding and color banding. Color bands and U.S. Fish and Wildlife Service (USFWS) bands applied to Willow Flycatchers from 1988-1995 resulted in an overall leg injury rate of 9.6% to birds returning to our study areas in subsequent years. Most injuries occurred on legs with only color band(s) (58.3%) or on legs with both a USFWS band and a color band (35%); only 6.7% of injuries (4/60) were due to USFWS bands alone, yielding an overall USFWS band injury rate of only 0.6%. Injuries ranged from severe (swollen, bleeding legs; a missing foot) to relatively minor (irritations on the tarsus). Amputation of the foot occurred in 33.9% of the cases. Return rates of adult injured birds in the year(s) following injury were significantly lower than for the population at large.
Experiments in balance with a 2D one-legged hopping machine
NASA Astrophysics Data System (ADS)
Raibert, M. H.; Brown, H. B., Jr.
1984-03-01
The ability to balance is important to the mobility obtained by legged creatures found in nature, and may someday lead to versatile legged vehicles. In order to study the role of balance in legged locomotion and to develop appropriate control strategies, a 2D hopping machine was constructed for experimentation. The machine has one leg on which it hops and runs, making balance a prime consideration. Control of the machine's locomotion was decomposed into three separate parts: a vertical height control part, a horizontal velocity part, and an angular attitude control part. Experiments showed that the three part control scheme, while very simple to implement, was powerful enough to permit the machine to hop in place, to run at a desired rate, to translate from place to place, and to leap over obstacles. Results from modeling and computer simulation of a similar one-legged device are described by Raibert (1983).
Soy undecapeptide induces Drosophila hind leg grooming via dopamine receptor.
Karim, M Rezaul; Yanagawa, Aya; Ohinata, Kousaku
2018-05-15
β-Conglycinin α subunit (323-333) [βCGα(323-333)] is an exogenous neuromodulating undecapeptide found from enzymatic digest of β-conglycinin, a soy major storage protein by mice behavior tests. We investigated effect of βCGα(323-333) on Drosophila behavior. Oral administration of βCGα(323-333) in Drosophila increased hind leg grooming, which may act through specific sets of neurons. It was reported that dopamine receptor (DopR) meditates hind leg grooming, and we tested involvement of DopR in βCGα(323-333)-induced hind leg grooming by using DopR knockout flies. In the wild type but not in the DopR-knockout flies, βCGα(323-333) increased hind leg grooming. These results suggest that βCGα(323-333) induces hind leg grooming via activating the DopR. This is the first report showing that exogenously administered peptide changes fly behaviors. Copyright © 2018 Elsevier Inc. All rights reserved.
A Behavioral Mechanism of How Increases in Leg Strength Improve Old Adults’ Gait Speed
Uematsu, Azusa; Tsuchiya, Kazushi; Kadono, Norio; Kobayashi, Hirofumi; Kaetsu, Takamasa; Hortobágyi, Tibor; Suzuki, Shuji
2014-01-01
We examined a behavioral mechanism of how increases in leg strength improve healthy old adults’ gait speed. Leg press strength training improved maximal leg press load 40% (p = 0.001) and isometric strength in 5 group of leg muscles 32% (p = 0.001) in a randomly allocated intervention group of healthy old adults (age 74, n = 15) but not in no-exercise control group (age 74, n = 8). Gait speed increased similarly in the training (9.9%) and control (8.6%) groups (time main effect, p = 0.001). However, in the training group only, in line with the concept of biomechanical plasticity of aging gait, hip extensors and ankle plantarflexors became the only significant predictors of self-selected and maximal gait speed. The study provides the first behavioral evidence regarding a mechanism of how increases in leg strength improve healthy old adults’ gait speed. PMID:25310220
Sensorimotor state of the contralateral leg affects ipsilateral muscle coordination of pedaling.
Ting, L H; Raasch, C C; Brown, D A; Kautz, S A; Zajac, F E
1998-09-01
The objective of this study was to determine if independent central pattern generating elements controlling the legs in bipedal and unipedal locomotion is a viable theory for locomotor propulsion in humans. Coordinative coupling of the limbs could then be accomplished through mechanical interactions and ipsilateral feedback control rather than through central interlimb neural pathways. Pedaling was chosen as the locomotor task to study because interlimb mechanics can be significantly altered, as pedaling can be executed with the use of either one leg or two legs (cf. walking) and because the load on the limb can be well-controlled. Subjects pedaled a modified bicycle ergometer in a two-legged (bilateral) and a one-legged (unilateral) pedaling condition. The loading on the leg during unilateral pedaling was designed to be identical to the loading experienced by the leg during bilateral pedaling. This loading was achieved by having a trained human "motor" pedal along with the subject and exert on the opposite crank the torque that the subject's contralateral leg generated in bilateral pedaling. The human "motor" was successful at reproducing each subject's one-leg crank torque. The shape of the motor's torque trajectory was similar to that of subjects, and the amount of work done during extension and flexion was not significantly different. Thus the same muscle coordination pattern would allow subjects to pedal successfully in both the bilateral and unilateral conditions, and the afferent signals from the pedaling leg could be the same for both conditions. Although the overall work done by each leg did not change, an 86% decrease in retarding (negative) crank torque during limb flexion was measured in all 11 subjects during the unilateral condition. This corresponded to an increase in integrated electromyography of tibialis anterior (70%), rectus femoris (43%), and biceps femoris (59%) during flexion. Even given visual torque feedback in the unilateral condition, subjects still showed a 33% decrease in negative torque during flexion. These results are consistent with the existence of an inhibitory pathway from elements controlling extension onto contralateral flexion elements, with the pathway operating during two-legged pedaling but not during one-legged pedaling, in which case flexor activity increases. However, this centrally mediated coupling can be overcome with practice, as the human "motor" was able to effectively match the bilateral crank torque after a longer practice regimen. We conclude that the sensorimotor control of a unipedal task is affected by interlimb neural pathways. Thus a task performed unilaterally is not performed with the same muscle coordination utilized in a bipedal condition, even if such coordination would be equally effective in the execution of the unilateral task.
Weber, Markus; Woerner, Michael; Springorum, Robert; Sendtner, Ernst; Hapfelmeier, Alexander; Grifka, Joachim; Renkawitz, Tobias
2014-10-01
Restoration of biomechanics is a major goal in THA. Imageless navigation enables intraoperative control of leg length equalization and offset reconstruction. However, the effect of navigation compared with intraoperative fluoroscopy is unclear. We asked whether intraoperative use of imageless navigation (1) improves the relative accuracy of leg length and global and femoral offset restoration; (2) increases the absolute precision of leg length and global and femoral offset equalization; and (3) reduces outliers in a reconstruction zone of ± 5 mm for leg length and global and femoral offset restoration compared with intraoperative fluoroscopy during minimally invasive (MIS) THA with the patient in a lateral decubitus position. In this prospective study a consecutive series of 125 patients were randomized to either navigation-guided or fluoroscopy-controlled THA using sealed, opaque envelopes. All patients received the same cementless prosthetic components through an anterolateral MIS approach while they were in a lateral decubitus position. Leg length, global or total offset (representing the combination of femoral and acetabular offset), and femoral offset differences were restored using either navigation or fluoroscopy. Postoperatively, residual leg length and global and femoral offset discrepancies were analyzed on magnification-corrected radiographs of the pelvis by an independent and blinded examiner using digital planning software. Accuracy was defined as the relative postoperative difference between the surgically treated and the unaffected contralateral side for leg length and offset, respectively; precision was defined as the absolute postoperative deviation of leg length and global and femoral offset regardless of lengthening or shortening of leg length and offset throughout the THA. All analyses were performed per intention-to-treat. Analyzing the relative accuracy of leg length restoration we found a mean difference of 0.2 mm (95% CI, -1.0 to +1.4 mm; p = 0.729) between fluoroscopy and navigation, 0.2 mm (95 % CI, -0.9 to +1.3 mm; p = 0.740) for global offset and 1.7 mm (95 % CI, +0.4 to +2.9 mm; p = 0.008) for femoral offset. For the absolute precision of leg length and global and femoral offset equalization, there was a mean difference of 1.7 ± 0.3 mm (p < 0.001) between fluoroscopy and navigation. The biomechanical reconstruction with a residual leg length and global and femoral offset discrepancy less than 5 mm and less than 8 mm, respectively, succeeded in 93% and 98%, respectively, in the navigation group and in 54% and 95%, respectively, in the fluoroscopy group. Intraoperative fluoroscopy and imageless navigation seem equivalent in accuracy and precision to reconstruct leg length and global and femoral offset during MIS THA with the patient in the lateral decubitus position.
Yoon, Jeong-Oh; Kang, Min-Hyeok; Kim, Jun-Seok; Oh, Jae-Seop
This is a cross-sectional study. University research laboratory. Fifteen healthy adults (mean age: 27.47 years) volunteered for this study. The individuals performed standard bridge exercise and modified bridge exercises with right leg-lift (single-leg-lift bridge exercise, single-leg-lift bridge exercise on an unstable surface, and single-leg-lift hip abduction bridge exercise). During the bridge exercises, electromyography of the rectus abdominis, internal oblique, erector spinae, and multifidus muscles was recorded using a wireless surface electromyography system. Two-way repeated-measures analysis of variance (exercise by side) with post hoc pairwise comparisons using Bonferroni correction was used to compare the electromyography data collected from each muscle. Bilateral internal oblique muscle activities showed significantly greater during single-leg-lift bridge exercise (95% confidence interval: right internal oblique=-8.99 to -1.08, left internal oblique=-6.84 to -0.10), single-leg-lift bridge exercise on an unstable surface (95% confidence interval: right internal oblique=-7.32 to -1.78, left internal oblique=-5.34 to -0.99), and single-leg-lift hip abduction bridge exercise (95% confidence interval: right internal oblique=-17.13 to -0.89, left internal oblique=-8.56 to -0.60) compared with standard bridge exercise. Bilateral rectus abdominis showed greater electromyography activity during single-leg-lift bridge exercise on an unstable surface (95% confidence interval: right rectus abdominis=-9.33 to -1.13, left rectus abdominis=-4.80 to -0.64) and single-leg-lift hip abduction bridge exercise (95% confidence interval: right rectus abdominis=-14.12 to -1.84, left rectus abdominis=-6.68 to -0.16) compared with standard bridge exercise. In addition, the right rectus abdominis muscle activity was greater during single-leg-lift hip abduction bridge exercise compared with single-leg-lift bridge exercise on an unstable surface (95% confidence interval=-7.51 to -0.89). For erector spinae, muscle activity was greater in right side compared with left side during all exercises (95% confidence interval: standard bridge exercise=0.19-4.53, single-leg-lift bridge exercise=0.24-10.49, single-leg-lift bridge exercise on an unstable surface=0.74-8.55, single-leg-lift hip abduction bridge exercise=0.47-11.43). There was no significant interaction and main effect for multifidus. Adding hip abduction and unstable conditions to bridge exercises may be useful strategy to facilitate the co-activation of trunk muscles. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Locomotion on the water surface: hydrodynamic constraints on rowing velocity require a gait change
Suter; Wildman
1999-10-01
Fishing spiders, Dolomedes triton (Araneae, Pisauridae), propel themselves across the water surface using two gaits: they row with four legs at sustained velocities below 0.2 m s(-)(1) and they gallop with six legs at sustained velocities above 0.3 m s(-)(1). Because, during rowing, most of the horizontal thrust is provided by the drag of the leg and its associated dimple as both move across the water surface, the integrity of the dimple is crucial. We used a balance, incorporating a biaxial clinometer as the transducer, to measure the horizontal thrust forces on a leg segment subjected to water moving past it in non-turbulent flow. Changes in the horizontal forces reflected changes in the status of the dimple and showed that a stable dimple could exist only under conditions that combined low flow velocity, shallow leg-segment depth and a long perimeter of the interface between the leg segment and the water. Once the dimple disintegrated, leaving the leg segment submerged, less drag was generated. Therefore, the disintegration of the dimple imposes a limit on the efficacy of rowing with four legs. The limited degrees of freedom in the leg joints (the patellar joints move freely in the vertical plane but allow only limited flexion in other planes) impose a further constraint on rowing by restricting the maximum leg-tip velocity (to approximately 33 % of that attained by the same legs during galloping). This confines leg-tip velocities to a range at which maintenance of the dimple is particularly important. The weight of the spider also imposes constraints on the efficacy of rowing: because the drag encountered by the leg-cum-dimple is proportional to the depth of the dimple and because dimple depth is proportional to the supported weight, only spiders with a mass exceeding 0.48 g can have access to the full range of hydrodynamically possible dimple depths during rowing. Finally, the maximum velocity attainable during rowing is constrained by the substantial drag experienced by the spider during the glide interval between power strokes, drag that is negligible for a galloping spider because, for most of each inter-stroke interval, the spider is airborne. We conclude that both hydrodynamic and anatomical constraints confine rowing spiders to sustained velocities lower than 0.3 m s(-)(1), and that galloping allows spiders to move considerably faster because galloping is free of these constraints.
Leg exoskeleton reduces the metabolic cost of human hopping.
Grabowski, Alena M; Herr, Hugh M
2009-09-01
During bouncing gaits such as hopping and running, leg muscles generate force to enable elastic energy storage and return primarily from tendons and, thus, demand metabolic energy. In an effort to reduce metabolic demand, we designed two elastic leg exoskeletons that act in parallel with the wearer's legs; one exoskeleton consisted of a multiple leaf (MLE) and the other of a single leaf (SLE) set of fiberglass springs. We hypothesized that hoppers, hopping on both legs, would adjust their leg stiffness while wearing an exoskeleton so that the combination of the hopper and exoskeleton would behave as a linear spring-mass system with the same total stiffness as during normal hopping. We also hypothesized that decreased leg force generation while wearing an exoskeleton would reduce the metabolic power required for hopping. Nine subjects hopped in place at 2.0, 2.2, 2.4, and 2.6 Hz with and without an exoskeleton while we measured ground reaction forces, exoskeletal compression, and metabolic rates. While wearing an exoskeleton, hoppers adjusted their leg stiffness to maintain linear spring-mass mechanics and a total stiffness similar to normal hopping. Without accounting for the added weight of each exoskeleton, wearing the MLE reduced net metabolic power by an average of 6% and wearing the SLE reduced net metabolic power by an average of 24% compared with hopping normally at frequencies between 2.0 and 2.6 Hz. Thus, when hoppers used external parallel springs, they likely decreased the mechanical work performed by the legs and substantially reduced metabolic demand compared with hopping without wearing an exoskeleton.
Locomotor-Like Leg Movements Evoked by Rhythmic Arm Movements in Humans
Sylos-Labini, Francesca; Ivanenko, Yuri P.; MacLellan, Michael J.; Cappellini, Germana; Poppele, Richard E.; Lacquaniti, Francesco
2014-01-01
Motion of the upper limbs is often coupled to that of the lower limbs in human bipedal locomotion. It is unclear, however, whether the functional coupling between upper and lower limbs is bi-directional, i.e. whether arm movements can affect the lumbosacral locomotor circuitry. Here we tested the effects of voluntary rhythmic arm movements on the lower limbs. Participants lay horizontally on their side with each leg suspended in an unloading exoskeleton. They moved their arms on an overhead treadmill as if they walked on their hands. Hand-walking in the antero-posterior direction resulted in significant locomotor-like movements of the legs in 58% of the participants. We further investigated quantitatively the responses in a subset of the responsive subjects. We found that the electromyographic (EMG) activity of proximal leg muscles was modulated over each cycle with a timing similar to that of normal locomotion. The frequency of kinematic and EMG oscillations in the legs typically differed from that of arm oscillations. The effect of hand-walking was direction specific since medio-lateral arm movements did not evoke appreciably leg air-stepping. Using externally imposed trunk movements and biomechanical modelling, we ruled out that the leg movements associated with hand-walking were mainly due to the mechanical transmission of trunk oscillations. EMG activity in hamstring muscles associated with hand-walking often continued when the leg movements were transiently blocked by the experimenter or following the termination of arm movements. The present results reinforce the idea that there exists a functional neural coupling between arm and legs. PMID:24608249
Influence of two catching methods on the occurrence of lesions in broilers.
Langkabel, Nina; Baumann, Maximilian P O; Feiler, Annika; Sanguankiat, Arsooth; Fries, Reinhard
2015-08-01
During the catching of broilers for slaughter, 2 to 3 birds are grabbed per hand at one leg at the same time. From an animal welfare point of view, this procedure is under critical observation from animal welfare administration and the general public.In this paper 2 catching methods were compared: the routinely used 1-leg catching method, and a second tech-nique whereby birds were grabbed by both legs with a maximum of 2 birds per hand (2-leg catching method). Lesions on the body, legs, and wings (hemorrhages and fractures) were recorded by a camera system located after the plucking position. Two weight classes, 2 catching teams, and 2 flocks were included in the study.Heavy animals showed more lesions than birds of the light weight class. In all investigations, lesions on the body and legs were rare, whereas wing lesions occurred at a rate of up to 15.32%. Statistical analysis showed no significant difference between the 2 methods or between the catching teams for both weight classes. A correlation between lesions and weight was observed, with a significant odds ratio ( OR: ) of 3.6 (95% CI: 3.299-3.957).During 2-leg catching, the animals appeared to be more restless. Workers stated that the grabbing of both legs of a bird was more difficult and that working in a crouching position for a longer time was harder.We conclude that the cautious handling of animals to reduce stress is more important than "holding animals by both legs", as has been proposed. © 2015 Poultry Science Association Inc.
Ocean Drilling Program: Public Information: Life Onboard JOIDES Resolution
2002) Leg 200 (Dec 2001-Jan 2002) Legs 190-199 Legs 176-189 Life Onboard JOIDES Resolution The reports hope that they provide a better understanding of the research activities and lifestyle of the
Stang, Julie; Wiig, Håvard; Hermansen, Marte; Hansen, Ernst Albin
2016-01-01
Understanding of behavior and control of human voluntary rhythmic stereotyped leg movements is useful in work to improve performance, function, and rehabilitation of exercising, healthy, and injured humans. The present study aimed at adding to the existing understanding within this field. To pursue the aim, correlations between freely chosen movement frequencies in relatively simple, single-joint, one- and two-legged knee extension exercise were investigated. The same was done for more complex, multiple-joint, one- and two-legged pedaling. These particular activities were chosen because they could be considered related to some extent, as they shared a key aspect of knee extension, and because they at the same time were different. The activities were performed at submaximal intensities, by healthy individuals (n = 16, thereof eight women; 23.4 ± 2.7 years; 1.70 ± 0.11 m; 68.6 ± 11.2 kg). High and fair correlations (R-values of 0.99 and 0.75) occurred between frequencies generated with the dominant leg and the nondominant leg during knee extension exercise and pedaling, respectively. Fair to high correlations (R-values between 0.71 and 0.95) occurred between frequencies performed with each of the two legs in an activity, and the two-legged frequency performed in the same type of activity. In general, the correlations were higher for knee extension exercise than for pedaling. Correlations between knee extension and pedaling frequencies were of modest occurrence. The correlations between movement frequencies generated separately by each of the legs might be interpreted to support the following working hypothesis, which was based on existing literature. It is likely that involved central pattern generators (CPGs) of the two legs share a common frequency generator or that separate frequency generators of each leg are attuned via interneuronal connections. Further, activity type appeared to be relevant. Thus, the apparent common rhythmogenesis for the two legs appeared to be stronger for the relatively simple single-joint activity of knee extension exercise as compared to the more complex multi-joint activity of pedaling. Finally, it appeared that the shared aspect of knee extension in the related types of activities of knee extension exercise and pedaling was insufficient to cause obvious correlations between generated movement frequencies in the two types of activities. PMID:26973486
Effect of rubber flooring on dairy cattle stepping behavior and muscle activity.
Rajapaksha, Eranda; Winkler, Christoph; Tucker, Cassandra B
2015-04-01
Use of compressible flooring, such as rubber, has increased on dairy farms. Rubber improves locomotion and is well used by cattle in preference experiments that combine walking and standing. Previous work has found that rubber is particularly beneficial for lame animals, perhaps because a softer material is particularly useful when a single hoof is compromised. The goal of this work was to evaluate the effect of flooring while standing, because cattle in freestall housing spend 40 to 50% of their time engaged in this behavior. In a 2 × 2 design, cows (n = 16) were evaluated on 4 standing surfaces that varied in terms of both floor type (concrete or rubber) and presentation [same floor under all 4 legs (all 4 legs on either concrete or rubber) or a rough surface under only one hind leg and the other 3 legs on concrete or rubber] in a crossover design. Surface electromyograms were used to evaluate muscle fatigue, total activity, and movement of muscle activity between legs during 1 h of standing. Muscle fatigue was evaluated in 2 contexts: (1) static contractions when cows continuously transferred weight to each hind leg, before and after 1 h of standing, and (2) dynamic contractions associated with steps during 1 h on treatment surfaces. In addition, stepping rate, time between each consecutive step, and the latency to lie down after testing were measured. No interaction between floor type and presentation was found. Presentation had a significant effect; when one hind leg was on a rough surface, cattle took 1.7 times more steps with this leg and the non-rough hind leg had 1.2 times more muscle activity, compared with when all 4 legs were on the same surface. These changes are consistent with movement away from concrete with protrusions. When standing on rubber, muscle-activity movements among legs remained stable (0.6-0.7 movements per min) over 1 h but increased on concrete (0.6-0.9 movements per min), indicating that, like humans, cattle may sway to counteract effects of standing. However, additional work, including measurements of blood flow in the leg, is needed to fully understand the biological implications of these changes. Overall, the rubber flooring tested had little effect on standing behavior. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Modelling the Somatic Electrical Response of Hippocampal Pyramidal Neurons
1989-09-01
postulated in the present study, and b) an approximation of the electrotonic structure of the cell that is derived in this thesis , based on data for the...the literature or postulated in the present study, and b) an approximation of the electrotonic structure of the cell that is derived in this thesis ...postulated in the present study, and b) an approximation of the electrotonic structure of the cell that is derived in this thesis , based on data for
A random access memory immune to single event upset using a T-Resistor
Ochoa, A. Jr.
1987-10-28
In a random access memory cell, a resistance ''T'' decoupling network in each leg of the cell reduces random errors caused by the interaction of energetic ions with the semiconductor material forming the cell. The cell comprises two parallel legs each containing a series pair of complementary MOS transistors having a common gate connected to the node between the transistors of the opposite leg. The decoupling network in each leg is formed by a series pair of resistors between the transistors together with a third resistor interconnecting the junction between the pair of resistors and the gate of the transistor pair forming the opposite leg of the cell. 4 figs.
Liquid-metal dip seal with pneumatic spring
Poindexter, Allan M.
1977-01-01
An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.
Photovoltaic array with minimally penetrating rooftop support system
Lenox, Carl J.S.
2012-10-23
A photovoltaic array including a plurality of photovoltaic assemblies and a plurality of mounting units. The mounting units each include an elongate rail and a plurality of leg assemblies. The rail is sized and configured to maintain a portion of at least two of the photovoltaic assemblies, with the leg assemblies extending from the rail in a spaced-apart fashion and terminating in a foot for placement against a rooftop structure for minimally penetration installation. Further, at least one of the leg assemblies can include a retractable leg. When the photovoltaic array is installed to a rooftop structure including a membrane intermittently secured to a rooftop deck, the retractable leg accommodates upward billowing of the membrane under windy conditions.
Random access memory immune to single event upset using a T-resistor
Ochoa, Jr., Agustin
1989-01-01
In a random access memory cell, a resistance "T" decoupling network in each leg of the cell reduces random errors caused by the interaction of energetic ions with the semiconductor material forming the cell. The cell comprises two parallel legs each containing a series pair of complementary MOS transistors having a common gate connected to the node between the transistors of the opposite leg. The decoupling network in each leg is formed by a series pair of resistors between the transistors together with a third resistor interconnecting the junction between the pair of resistors and the gate of the transistor pair forming the opposite leg of the cell.
Trunk orientation causes asymmetries in leg function in small bird terrestrial locomotion.
Andrada, Emanuel; Rode, Christian; Sutedja, Yefta; Nyakatura, John A; Blickhan, Reinhard
2014-12-22
In contrast to the upright trunk in humans, trunk orientation in most birds is almost horizontal (pronograde). It is conceivable that the orientation of the heavy trunk strongly influences the dynamics of bipedal terrestrial locomotion. Here, we analyse for the first time the effects of a pronograde trunk orientation on leg function and stability during bipedal locomotion. For this, we first inferred the leg function and trunk control strategy applied by a generalized small bird during terrestrial locomotion by analysing synchronously recorded kinematic (three-dimensional X-ray videography) and kinetic (three-dimensional force measurement) quail locomotion data. Then, by simulating quail gaits using a simplistic bioinspired numerical model which made use of parameters obtained in in vivo experiments with real quail, we show that the observed asymmetric leg function (left-skewed ground reaction force and longer leg at touchdown than at lift-off) is necessary for pronograde steady-state locomotion. In addition, steady-state locomotion becomes stable for specific morphological parameters. For quail-like parameters, the most common stable solution is grounded running, a gait preferred by quail and most of the other small birds. We hypothesize that stability of bipedal locomotion is a functional demand that, depending on trunk orientation and centre of mass location, constrains basic hind limb morphology and function, such as leg length, leg stiffness and leg damping. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Kibsgård, Thomas J; Røise, Olav; Sturesson, Bengt; Röhrl, Stephan M; Stuge, Britt
2014-04-01
Chamberlain's projections (anterior-posterior X-ray of the pubic symphysis) have been used to diagnose sacroiliac joint mobility during the single-leg stance test. This study examined the movement in the sacroiliac joint during the single-leg stance test with precise radiostereometric analysis. Under general anesthesia, tantalum markers were inserted into the dorsal sacrum and the ilium of 11 patients with long-lasting and severe pelvic girdle pain. After two to three weeks, a radiostereometric analysis was conducted while the subjects performed a single-leg stance. Small movements were detected in the sacroiliac joint during the single-leg stance. In both the standing- and hanging-leg sacroiliac join, a total of 0.5 degree rotation was observed; however, no translations were detected. There were no differences in total movement between the standing- and hanging-leg sacroiliac joint. The movement in the sacroiliac joint during the single-leg stance is small and almost undetectable by the precise radiostereometric analysis. A complex movement pattern was seen during the test, with a combination of movements in the two joints. The interpretation of the results of this study is that, the Chamberlain examination likely is inadequate in the examination of sacroiliac joint movement in patients with pelvic girdle pain. Copyright © 2014 Elsevier Ltd. All rights reserved.
Snijders, Chris J; Hermans, Paul F G; Kleinrensink, Gerrit Jan
2006-02-01
Transversely oriented pelvic muscles such as the internal abdominal oblique, transversus abdominis, piriformis and pelvic floor muscles may contribute to sacroiliac joint stability by pressing the sacrum between the hipbones. Surface electromyographic measurements showed that leg crossing lowers the activity of the internal oblique abdominal muscle significantly. This suggests that leg crossing is a substitute for abdominal muscle activity. No previous studies addressed piriformis muscle and related pelvic structures in cross-legged sitting. Angles of pelvis and femur were measured in healthy subjects in standing, normal sitting and cross-legged sitting, and were used to simulate these postures on embalmed pelvises and measure piriformis muscle elongation. Deformations of pelvic ring and iliolumbar ligament caused by piriformis muscle force were measured on embalmed pelvises. Cross-legged sitting resulted in a relative elongation of the piriformis muscle of 11.7% compared to normal sitting and even 21.4% compared to standing. Application of piriformis muscle force resulted in inward deformation of the pelvic ring and compression of the sacroiliac joints and the dorsal side of the pubic symphysis. Cross-legged sitting is common. We believe that it contributes to sacroiliac joint stability. This study demonstrates the influence of the piriformis muscle on sacroiliac joint compression. The elongation of the piriformis muscle bilaterally by crossing the legs may be functional in the build-up of active or passive tension between sacrum and femur.
Three new Batillipes species (Arthrotardigrada: Batillipedidae) from the Brazilian coast.
Santos, Erika; Rocha, Clélia M C DA; Gomes, Edivaldo Jr; Fontoura, Paulo
2017-03-16
Three new tardigrade species, Batillipes brasiliensis sp. nov., Batillipes dandarae sp. nov. and Batillipes potiguarensis sp. nov., are described from shallow subtidal sediments of the Brazilian coast. B. brasiliensis sp. nov. and B. dandarae sp. nov. have toes 3 and 4 on leg IV different in length, so they can be included in the D group of species, while B. potiguarensis sp. nov., with toes 3 and 4 on leg IV equal in length belong to the A group. Batillipes brasiliensis sp. nov. is characterized by having an ala-like caudal expansion; cuticular projections on the coxal region of legs I-III, and lateral projections. The lateral projection located between the third and fourth legs is fringed with digit-shaped expansions. Batillipes dandarae sp. nov. has a dorsal blunt enlargement in the scapular region; a pointed triangular caudal appendage, and no lateral projections. The new species exhibits a sensorial spine on legs I inserted posteriorly and turning forward, and anus surrounded by a peculiar cuticular structure constituted by six platelets. Batillipes potiguarensis sp. nov. is characterized by a unique combination of characters: scapular region well developed, protruding laterally at the level of the first pair of legs; lateral blunt processes between legs, and prominent roundish caudal protrusion. In addition, the new species exhibits cephalic appendages with swollen tips, evident secondary clavae, and very short sense organs on the legs IV.
Chronic leg ulceration in homozygous sickle cell disease: the role of venous incompetence.
Clare, Andrea; FitzHenley, Michael; Harris, June; Hambleton, Ian; Serjeant, Graham R
2002-11-01
Chronic leg ulceration is a common cause of morbidity in Jamaican patients with homozygous sickle cell (SS) disease. Ulcers heal more rapidly on bed rest and deteriorate on prolonged standing, suggesting a role of venous hypertension in their persistence. This hypothesis has been tested by Doppler detection of venous competence in SS patients and in matched controls with a normal haemoglobin (AA) genotype in the Jamaican Cohort Study. Venous incompetence was significantly more frequent in SS disease [137/183 (75%)] than in non-pregnant AA controls [53/137 (39%)]. Past or present ulceration occurred in 78 (43%) SS patients, with a highly significant association between leg ulceration and venous incompetence in the same leg (P < 0.001). Prominence and/or varicosities of the veins and spontaneous leg ulcers were more common among patients with multiple sites of incompetence. The association of venous incompetence with chronic leg ulceration identifies a further pathological mechanism contributing to the morbidity of SS disease. The cause of venous incompetence is unknown but the sluggish circulation associated with dependency, turbidity and impaired linear flow at venous valves, hypoxia-induced sickling, the rheological effects of high white cell counts, and activation of components of the coagulation system may all contribute. Venous hypertension in SS patients with leg ulceration suggests that firm elastic supportive dressings might promote healing of chronic leg ulcers.
Beaulieu, M L; Palmieri-Smith, R M
2014-08-01
Excessive knee abduction loading is a contributing factor to anterior cruciate ligament (ACL) injury risk. The purpose of this study was to determine whether a double-leg landing training program with real-time visual feedback improves frontal-plane mechanics during double- and single-leg landings. Knee abduction angles and moments and vertical ground reaction forces (GRF) of 21 recreationally active women were quantified for double- and single-leg landings before and after the training program. This program consisted of two sessions of double-leg jump landings with real-time visual feedback on knee abduction moments for the experimental group and without real-time feedback for the control group. No significant differences were found between training groups. In comparison with pre-training data, peak knee abduction moments decreased 12% post-training for both double- and single-leg landings; whereas peak vertical GRF decreased 8% post-training for double-leg landings only, irrespective of training group. Real-time feedback on knee abduction moments, therefore, did not significantly improve frontal-plane knee mechanics during landings. The effect of the training program on knee abduction moments, however, transferred from the double-leg landings (simple task) to single-leg landings (more complex task). Consequently, ACL injury prevention efforts may not need to focus on complex tasks during which injury occurs. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A new index of flat breaststroke propulsion: a comparison of elite men and women.
Seifert, L; Chollet, D
2005-03-01
This study examined arm and leg coordination and propulsion during the flat breaststroke in nine elite male and eight elite female swimmers over three race paces (200 m, 100 m and 50 m). Coordination was expressed using four temporal gaps (T1, T2, T3, T4), which described the continuity between the propulsive phases of the limbs, as recorded on a video device (50 Hz). Glide duration was denoted T1, the time between the beginning of arm and leg recovery was denoted T2, the time between the end of arm and the leg recovery was denoted T3, and the time between 90 degrees of flexion during arm recovery and 90 degrees during leg recovery was denoted T4. Using these temporal gaps, four stroke phases (propulsion, glide, recovery and leg insweep) could be followed over a complete arm and leg stroke. The total duration of arm and leg propulsion was assessed by a new index of flat breaststroke propulsion (IFBP). Velocity, stroke rate and stroke length were also calculated for each pace. The elite swimmers showed short T2, T3 and T4; moreover, T1 decreased when the pace increased. Expertise in the flat breaststroke was thus characterized by synchronized arm and leg recoveries and increased continuity in the arm and leg propulsions with increasing velocity. Differences between the sexes in the spatio-temporal parameters were possibly due to anthropometric differences (the men were heavier, older and taller than the women) and different motor organization linked to arm and leg coordination (shorter T3, body glide and body recovery, and greater body propulsion and higher IFBP in the men). The men's propulsive actions showed greater continuity, particularly in the sprint. The best men adopted a superposition coordination and thus had the ability to overcome very great active drag. Temporal gap measurement and the IFBP are practical indicators of arm and leg coordination and propulsion that can be exploited by coaches and swimmers to increase the continuity between propulsive actions during the flat breaststroke.
Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J
2018-06-09
Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.
Genetic analysis of feet and leg conformation traits in Nelore cattle.
Vargas, G; Neves, H H R; Cardoso, V; Munari, D P; Carvalheiro, R
2017-06-01
Feet and leg conformation scores are important traits in beef cattle because they encompass a wide range of locomotion disorders that can lead to productive and reproductive losses. Thus, the study of feet and legs in beef cattle is essential for evaluating possible responses to selection focusing on minimizing economic losses caused by the occurrence of feet and leg problems. The aim of this study was to estimate variance components for feet and leg conformation traits in Nelore cattle. The data set contained records of approximately 300,000 animals that were born between 2000 and 2013. These animals belonged to the commercial beef cattle breeding program of the CRV Lagoa (). Feet and legs were evaluated by assigning visual scores at 2 different time points: feet and leg evaluated as a binary trait (FL1), measured at yearling (about 550 d of age) to identify whether (or not) an animal has feet and leg defects, and feet and leg score (FL2), ranging from 1 (less desirable) to 5 (more desirable) was assigned to the top 20% of animals according to the selection index adopted by the beef cattle breeding program, which was measured 2 to 5 mo after the yearling evaluation. The FL1 and FL2 traits were analyzed together with yearling weight (YW). The (co)variance components and breeding values were estimated by Bayesian inference using 2-trait animal models. The posterior means (standard errors) of the heritabilities for FL1, FL2, and YW were 0.18 (0.04), 0.39 (0.07), and 0.47 (0.01), respectively. The results indicate that the incidence of feet and leg problems in this population might be reduced by selection. The genetic correlation between FL1 and FL2 (-0.47) was moderate and negative as expected because the classification score that holds up each trait has opposite numerical values. The genetic trends estimated for FL1 and FL2 (-0.042 and 0.021 genetic standard deviations per year, respectively) were favorable and they indicate that the independent culling strategy for feet and leg problems promotes favorable changes and contributes to the genetic progress of these traits in the population under study.
The trophic role of mesozooplankton at 47°N, 20°W during the North Atlantic Bloom Experiment
NASA Astrophysics Data System (ADS)
Dam, Hans G.; Miller, Carolyn A.; Jonasdottir, Sigrun H.
The biomass and grazing rates of three size classes of mesozooplankton—0.2-0.5 mm (small), 0.5-1.0 mm (medium) and 1.0-2.0 mm (large)—were quantified in the vicinity of 47°N, 20°W, from 25 April to 7 May (leg 4) and from 18 to 31 May 1989 (leg 5) as part of the North Atlantic Bloom Experiment (NABE) of the Joint Global Ocean Flux Study (JGOFS). Biomass was inversely related to body size, with the small size fraction accounting for > 50% of the entire mesozooplankton biomass. Diel differences in biomass, however, were directly related to body size, indicating that vertical migration became more pronounced as the size of the animals increased. Total zooplankton biomass increased by almost a factor of 3 from the beginning to the end of the study. The average carbon-weight of individuals increased six-fold from leg 4 to leg 5 of the study. Carbon-specific rates of phytoplankton ingestion were (1) inversely related to body size; (2) greater at night for all size fractions; and (3) generally greater on leg 4 than on leg 5, particularly for the small size fraction. Grazing was dominated by the small size fraction (66% of the total grazing) on leg 4 and by the medium size fraction (44% of the total grazing) on leg 5. The removal of the daily primary production by mesozooplankton was not different from leg 4 to leg 5, averaging 2.7% day -1 (range 0.6-5.2% day -1). Comparisons of (1) estimated metabolic rates and (2) measured nitrogen excretion rates with daily rations of carbon and nitrogen, respectively, for zooplankton suggest that a phytoplankton diet only contributed about 50% of the daily carbon and nitrogen rations of animals. We hypothesize that mesozooplankton fecal pellets contributed < 5% of the POC flux out of the euphotic zone measured with particle traps. However, we estimate that during leg 5, the active flux of dissolved nitrogen out of the euphotic zone due to mesozooplankton diel vertical migration was 26% of the passive PON flux.
How to Comply with Requirements to Protect California Red-legged Frog from Pesticides
This document describes buffer areas around certain habitats of the California red-legged frog, and limits on use of certain pesticides within those habitats and buffer zones to protect the red-legged frog from certain pesticides.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... Lower Leg Conditions Disability Benefits Questionnaire) Under OMB Review AGENCY: Veterans Benefits... Questionnaire)'' in any correspondence. FOR FURTHER INFORMATION CONTACT: Crystal Rennie, Enterprise Records... Conditions Disability Benefits Questionnaire)''. SUPPLEMENTARY INFORMATION: Title: Knee and Lower Leg...