Direct current hybrid breakers: A design and its realization
NASA Astrophysics Data System (ADS)
Atmadji, Ali Mahfudz Surya
2000-12-01
The use of semiconductors for electric power circuit breakers instead of conventional breakers remains a utopia when designing fault current interrupters for high power networks. The major problems concerning power semiconductor circuit breakers are the excessive heat losses and their sensitivity to transients. However, conventional breakers are capable of dealing with such matters. A combination of the two methods, or so-called `hybrid breakers', would appear to be a solution; however, hybrid breakers use separate parallel branches for conducting the main current and interrupting the short-circuit current. Such breakers are intended for protecting direct current (DC) traction systems. In this thesis hybrid switching techniques for current limitation and purely solidstate current interruption are investigated for DC breakers. This work analyzes the transient behavior of hybrid breakers and compares their operations with conventional breakers and similar solid-state devices in DC systems. Therefore a hybrid breaker was constructed and tested in a specially designed high power test circuit. A vacuum breaker was chosen as the main breaker in the main conducting path; then a commutation path was connected across the vacuum breaker where it provided current limitation and interruption. The commutation path operated only during any current interruption and the process required additional circuits. These included a certain energy storage, overvoltage suppressor and commutation switch. So that when discharging this energy, a controlled counter-current injection could be produced. That counter-current opposed the main current in the breaker by superposition in order to create a forced current-zero. One-stage and two-stage commutation circuits have been treated extensively. This study project contains both theoretical and experimental investigations. A direct current shortcircuit source was constructed capable of delivering power equivalent to a fault. It supplied a direct voltage of 1kVDC which was rectified having been obtained from a 3-phase lOkV/380V supply. The source was successfully tested to deliver a fault current of 7kA with a time constant of 5ms. The hybrid breaker that was developed could provide protection for 750VDC traction systems. The breaker was equipped with a fault- recognizing circuit based on a current level triggering. An electronic circuit was built for this need and was included in the system. It monitored the system continuously and took action by generating trip signals when a fault was recognized. Interruption was followed by a suitable timing of the fast contact separation in the main breaker and the current-zero creation. An electrodynamically driven mechanism was successfully tested having a dead-time of 300μs to separate the main breaker contacts. Furthermore, a maximum peak current injection of RA at a frequency of 500Hz could be obtained in order to produce an artificial current-zero in the vacuum breaker. A successful current interruption with a prospective value of RA was achieved by the hybrid switching technique. In addition, measures were taken to prevent overvoltages. Experimentally, the concept of a hybrid breaker was compared with the functioning of all mechanical (air breaker) and all electronical (IGCT breaker) versions. Although a single stage interrupting method was verified experimentally, two two-stage interrupting methods were analyzed theoretically.
Projective Identification in Common Couple Dances.
ERIC Educational Resources Information Center
Middelberg, Carol V.
2001-01-01
Integrates the object relations concept of projective identification and the systemic concept of marital dances to develop a more powerful model for working with more difficult and distressed couples. Suggests how object relations techniques can be used to interrupt projective identifications and resolve conflict on intrapsychic level so the…
Fundamental investigation of ARC interruption in gas flows
NASA Astrophysics Data System (ADS)
Benenson, D. M.; Frind, G.; Kinsinger, R. E.; Nagamatsu, H. T.; Noeske, H. O.; Sheer, R. E., Jr.
1980-07-01
Thermal recovery in gas blast interrupters is discussed. The thermal recovery process was investigated with physical and aerodynamic methods, typically using reduced size nozzles and short sinusoidal current pulses. Aerodynamic characterization of the cold flow fields in several different nozzle types included measurements of the pressure and flow fields, both steady-state and turbulent components, with special attention given to wakes and shock structures. Special schlieren techniques on DC arcs and high speed photography on arcs in orifice nozzles show that shock heating broadens the arc independent of turbulence effects and produces a poorly recovering downstream arc section. Measured recovery speeds in both orifice and convergent-divergent nozzles agree with predictions of several arc theories assuming turbulent power losses. However, data on post-zero currents and power loss show values much smaller than theoretical predictions. Hydrogen, deuterium, and methane were measured.
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-01-01
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique. PMID:27517931
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-08-10
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.
NASA Astrophysics Data System (ADS)
Reinovsky, R. E.; Levi, P. S.; Bueck, J. C.; Goforth, J. H.
The Air Force Weapons Laboratory, working jointly with Los Alamos National Laboratory, has conducted a series of experiments directed at exploring composite, or staged, switching techniques for use in opening switches in applications which require the conduction of very high currents (or current densities) with very low losses for relatively long times (several tens of microseconds), and the interruption of these currents in much shorter times (ultimately a few hundred nanoseconds). The results of those experiments are reported.
33 CFR 159.89 - Power interruption: Type I and II devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Power interruption: Type I and II devices. 159.89 Section 159.89 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.89 Power...
NASA Astrophysics Data System (ADS)
Khan, Mansoor; Yong, Wang; Mustafa, Ehtasham
2017-07-01
After the rapid advancement in the field of power electronics devices and drives for last few decades, there are different kinds of Pulse Width Modulation techniques which have been brought to the market. The applications ranging from industrial appliances to military equipment including the home appliances. The vey common application for the PWM is three phase voltage source inverter, which is used to convert DC to AC in the homes to supply the power to the house in case electricity failure, usually named as Un-interrupted Power Supply. In this paper Space Vector Pulse Width Modulation techniques is discussed and analysed under the control technique named as Field Oriented Control. The working and implementation of this technique has been studied by implementing on the three phase bridge inverter. The technique is used to control the Permanente Magnet Synchronous Motor. The drive system is successfully implemented in MATLAB/Simulink using the mathematical equation and algorithm to achieve the satisfactory results. PI type of controller is used to tuned ers of the motothe parametr i.e. torque and current.
A new encoding scheme for visible light communications with applications to mobile connections
NASA Astrophysics Data System (ADS)
Benton, David M.; St. John Brittan, Paul
2017-10-01
A new, novel and unconventional encoding scheme called concurrent coding, has recently been demonstrated and shown to offer interesting features and benefits in comparison to conventional techniques, such as robustness against burst errors and improved efficiency of transmitted power. Free space optical communications can suffer particularly from issues of alignment which requires stable, fixed links to be established and beam wander which can interrupt communications. Concurrent coding has the potential to help ease these difficulties and enable mobile, flexible optical communications to be implemented through the use of a source encoding technique. This concept has been applied for the first time to optical communications where standard light emitting diodes (LEDs) have been used to transmit information encoded with concurrent coding. The technique successfully transmits and decodes data despite unpredictable interruptions to the transmission causing significant drop-outs to the detected signal. The technique also shows how it is possible to send a single block of data in isolation with no pre-synchronisation required between transmitter and receiver, and no specific synchronisation sequence appended to the transmission. Such systems are robust against interference - intentional or otherwise - as well as intermittent beam blockage.
Improving the estimated cost of sustained power interruptions to electricity customers
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaCommare, Kristina Hamachi; Eto, Joseph H.; Dunn, Laurel N.
Electricity reliability and resiliency have become a topic of heightened interest in recent years in the United States. As utilities, regulators, and policymakers determine how to achieve optimal levels of electricity reliability while considering how best to prepare for future disruptions in power, the related issue of how much it costs when customers lose power remains a largely unanswered question. In 2006, Lawrence Berkeley National Laboratory developed an end-use based framework that estimates the cost of power interruptions in the U.S that has served as a foundational paper using the best available, yet far from perfect, information at that time.more » Since then, an abundance of work has been done to improve the quality and availability of information that now allow us to make a much more robust assessment of the cost of power interruptions to U.S. customers. In this paper, we find that the total U.S. cost of sustained power interruptions is 44 billion dollars per year (2015-) -25% more than the 26 billion dollars per year in 2002- (or 35 billion dollars per year in 2015-) estimated in our 2006 study.« less
Improving the estimated cost of sustained power interruptions to electricity customers
LaCommare, Kristina Hamachi; Eto, Joseph H.; Dunn, Laurel N.; ...
2018-04-18
Electricity reliability and resiliency have become a topic of heightened interest in recent years in the United States. As utilities, regulators, and policymakers determine how to achieve optimal levels of electricity reliability while considering how best to prepare for future disruptions in power, the related issue of how much it costs when customers lose power remains a largely unanswered question. In 2006, Lawrence Berkeley National Laboratory developed an end-use based framework that estimates the cost of power interruptions in the U.S that has served as a foundational paper using the best available, yet far from perfect, information at that time.more » Since then, an abundance of work has been done to improve the quality and availability of information that now allow us to make a much more robust assessment of the cost of power interruptions to U.S. customers. In this paper, we find that the total U.S. cost of sustained power interruptions is 44 billion dollars per year (2015-) -25% more than the 26 billion dollars per year in 2002- (or 35 billion dollars per year in 2015-) estimated in our 2006 study.« less
Formal Verification of a Power Controller Using the Real-Time Model Checker UPPAAL
NASA Technical Reports Server (NTRS)
Havelund, Klaus; Larsen, Kim Guldstrand; Skou, Arne
1999-01-01
A real-time system for power-down control in audio/video components is modeled and verified using the real-time model checker UPPAAL. The system is supposed to reside in an audio/video component and control (read from and write to) links to neighbor audio/video components such as TV, VCR and remote-control. In particular, the system is responsible for the powering up and down of the component in between the arrival of data, and in order to do so in a safe way without loss of data, it is essential that no link interrupts are lost. Hence, a component system is a multitasking system with hard real-time requirements, and we present techniques for modeling time consumption in such a multitasked, prioritized system. The work has been carried out in a collaboration between Aalborg University and the audio/video company B&O. By modeling the system, 3 design errors were identified and corrected, and the following verification confirmed the validity of the design but also revealed the necessity for an upper limit of the interrupt frequency. The resulting design has been implemented and it is going to be incorporated as part of a new product line.
Interrupting the balance: reconsidering the complexities of conflict in South Sudan.
Pendle, Naomi
2014-04-01
By the start of 2014, violent conflict had erupted across much of South Sudan following initial violence in Juba on 15 December 2013. The speed with which the fighting has spread raises questions regarding the impact of national-level politics on violence at the local level. This article develops a framework in which violent conflict can be comprehended as a response to the interruption of the negotiation of the balance of power between groups; the negotiation is interrupted when that balance tips in favour of one group, such as through changes in the national political market or government reforms. The article provides two cases studies of attempts to strengthen the state that inadvertently interrupted local power relations between groups. In response, the groups engaged in violent conflict to reinstate a balance of power. Both examples involve conflict among Dinka groups from 2005 to 2008. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.
Nested Interrupt Analysis of Low Cost and High Performance Embedded Systems Using GSPN Framework
NASA Astrophysics Data System (ADS)
Lin, Cheng-Min
Interrupt service routines are a key technology for embedded systems. In this paper, we introduce the standard approach for using Generalized Stochastic Petri Nets (GSPNs) as a high-level model for generating CTMC Continuous-Time Markov Chains (CTMCs) and then use Markov Reward Models (MRMs) to compute the performance for embedded systems. This framework is employed to analyze two embedded controllers with low cost and high performance, ARM7 and Cortex-M3. Cortex-M3 is designed with a tail-chaining mechanism to improve the performance of ARM7 when a nested interrupt occurs on an embedded controller. The Platform Independent Petri net Editor 2 (PIPE2) tool is used to model and evaluate the controllers in terms of power consumption and interrupt overhead performance. Using numerical results, in spite of the power consumption or interrupt overhead, Cortex-M3 performs better than ARM7.
AMTEC powered residential furnace and auxiliary power
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanenok, J.F. III; Sievers, R.K.
1996-12-31
Residential gas furnaces normally rely on utility grid electric power to operate the fans and/or the pumps used to circulate conditioned air or water and they are thus vulnerable to interruptions of utility grid service. Experience has shown that such interruptions can occur during the heating season, and can lead to serious consequences. A gas furnace coupled to an AMTEC conversion system retains the potential to produce heat and electricity (gas lines are seldom interrupted during power outages), and can save approximately $47/heating season compared to a conventional gas furnace. The key to designing a power system is understanding, andmore » predicting, the cell performance characteristics. The three main processes that must be understood and modeled to fully characterize an AMTEC cell are the electro-chemical, sodium vapor flow, and heat transfer. This paper will show the results of the most recent attempt to model the heat transfer in a multi-tube AMTEC cell and then discusses the conceptual design of a self-powered residential furnace.« less
Single frequency RF powered ECG telemetry system
NASA Technical Reports Server (NTRS)
Ko, W. H.; Hynecek, J.; Homa, J.
1979-01-01
It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.
NASA Technical Reports Server (NTRS)
Ludwig, Kimberly; Mackin, Michael; Wright, Theodore
1991-01-01
The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.
Operating health analysis of electric power systems
NASA Astrophysics Data System (ADS)
Fotuhi-Firuzabad, Mahmud
The required level of operating reserve to be maintained by an electric power system can be determined using both deterministic and probabilistic techniques. Despite the obvious disadvantages of deterministic approaches there is still considerable reluctance to apply probabilistic techniques due to the difficulty of interpreting a single numerical risk index and the lack of sufficient information provided by a single index. A practical way to overcome difficulties is to embed deterministic considerations in the probabilistic indices in order to monitor the system well-being. The system well-being can be designated as healthy, marginal and at risk. The concept of system well-being is examined and extended in this thesis to cover the overall area of operating reserve assessment. Operating reserve evaluation involves the two distinctly different aspects of unit commitment and the dispatch of the committed units. Unit commitment health analysis involves the determination of which unit should be committed to satisfy the operating criteria. The concepts developed for unit commitment health, margin and risk are extended in this thesis to evaluate the response well-being of a generating system. A procedure is presented to determine the optimum dispatch of the committed units to satisfy the response criteria. The impact on the response wellbeing being of variations in the margin time, required regulating margin and load forecast uncertainty are illustrated. The effects on the response well-being of rapid start units, interruptible loads and postponable outages are also illustrated. System well-being is, in general, greatly improved by interconnection with other power systems. The well-being concepts are extended to evaluate the spinning reserve requirements in interconnected systems. The interconnected system unit commitment problem is decomposed into two subproblems in which unit scheduling is performed in each isolated system followed by interconnected system evaluation. A procedure is illustrated to determine the well-being indices of the overall interconnected system. Under normal operating conditions, the system may also be able to carry a limited amount of interruptible load on top of its firm load without violating the operating criterion. An energy based approach is presented to determine the optimum interruptible load carrying capability in both the isolated and interconnected systems. Composite system spinning reserve assessment and composite system well-being are also examined in this research work. The impacts on the composite well-being of operating reserve considerations such as stand-by units, interruptible loads and the physical locations of these resources are illustrated. It is expected that the well-being framework and the concepts developed in this research work will prove extremely useful in the new competitive utility environment.
Larsen, Peter H.; LaCommare, Kristina H.; Eto, Joseph H.; ...
2016-10-27
Here, this study examines the relationship between annual changes in electricity reliability reported by a large cross-section of U.S. electricity distribution utilities over a period of 13 years and a broad set of potential explanatory variables, including weather and utility characteristics. We find statistically significant correlations between the average number of power interruptions experienced annually and above average wind speeds, precipitation, lightning strikes, and a measure of population density: customers per line mile. We also find significant relationships between the average number of minutes of power interruptions experienced and above average wind speeds, precipitation, cooling degree-days, and one strategy usedmore » to mitigate the impacts of severe weather: the amount of underground transmission and distribution line miles. Perhaps most importantly, we find a significant time trend of increasing annual average number of minutes of power interruptions over time—especially when interruptions associated with extreme weather are included. Lastly, the research method described in this analysis can provide a basis for future efforts to project long-term trends in reliability and the associated benefits of strategies to improve grid resiliency to severe weather—both in the U.S. and abroad.« less
Gurien, Lori A; Wyrick, Deidre L; Smith, Samuel D; Maxson, R Todd
2016-05-01
Although this issue remains unexamined, pediatric surgeons commonly use simple interrupted suture for bowel anastomosis, as it is thought to improve intestinal growth postoperatively compared to continuous running suture. However, effects on intestinal growth are unclear. We compared intestinal growth using different anastomotic techniques during the postoperative period in young rats. Young, growing rats underwent small bowel transection and anastomosis using either simple interrupted or continuous running technique. At 7-weeks postoperatively after a four-fold growth, the anastomotic site was resected. Diameters and burst pressures were measured. Thirteen rats underwent anastomosis with simple interrupted technique and sixteen with continuous running method. No differences were found in body weight at first (102.46 vs 109.75g) or second operations (413.85 vs 430.63g). Neither the diameters (0.69 vs 0.79cm) nor burst pressures were statistically different, although the calculated circumference was smaller in the simple interrupted group (2.18 vs 2.59cm; p=0.03). No ruptures occurred at the anastomotic line. This pilot study is the first to compare continuous running to simple interrupted intestinal anastomosis in a pediatric model and showed no difference in growth. Adopting continuous running techniques for bowel anastomosis in young children may lead to faster operative time without affecting intestinal growth. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Peter H.; LaCommare, Kristina H.; Eto, Joseph H.
Here, this study examines the relationship between annual changes in electricity reliability reported by a large cross-section of U.S. electricity distribution utilities over a period of 13 years and a broad set of potential explanatory variables, including weather and utility characteristics. We find statistically significant correlations between the average number of power interruptions experienced annually and above average wind speeds, precipitation, lightning strikes, and a measure of population density: customers per line mile. We also find significant relationships between the average number of minutes of power interruptions experienced and above average wind speeds, precipitation, cooling degree-days, and one strategy usedmore » to mitigate the impacts of severe weather: the amount of underground transmission and distribution line miles. Perhaps most importantly, we find a significant time trend of increasing annual average number of minutes of power interruptions over time—especially when interruptions associated with extreme weather are included. Lastly, the research method described in this analysis can provide a basis for future efforts to project long-term trends in reliability and the associated benefits of strategies to improve grid resiliency to severe weather—both in the U.S. and abroad.« less
Powering the Network: The Forgotten Infrastructure.
ERIC Educational Resources Information Center
Learn, Larry L., Ed.
1995-01-01
Discusses systems that power the telecommunications infrastructure. Highlights include power for central telephone company offices; private branch exchange systems; power interruptions and power irregularities; uninterruptible power systems; problems in the systems; and photovoltaic systems. (LRW)
Decision - making of Direct Customers Based on Available Transfer Capability
NASA Astrophysics Data System (ADS)
Quan, Tang; Zhaohang, Lin; Huaqiang, Li
2017-05-01
Large customer direct-power-purchasing is a hot spot in the electricity market reform. In this paper, the author established an Available Transfer Capability (ATC) model which takes uncertain factors into account, applied the model into large customer direct-power-purchasing transactions and improved the reliability of power supply during direct-power-purchasing by introducing insurance theory. The author also considered the customers loss suffered from power interruption when building ATC model, established large customer decision model, took purchasing quantity of power from different power plants and reserved capacity insurance as variables, targeted minimum power interruption loss as optimization goal and best solution by means of particle swarm algorithm to produce optimal power purchasing decision of large consumers. Simulation was made through IEEE57 system finally and proved that such method is effective.
A 2.5 Gigawatt Liquid Dielectric Coaxial Pulse Forming Line
1987-06-01
operation. The fuses provide protection against long term faults. The 3 phase vacuum contactor is a convenient means of remotely applying or...is electronically sensed and the vacuum contactor opens thereby interrupting the input power. The opening time of the vacuum contactor is less than...less than 5 microseconds and at the same time a trigger signal is sent to the vacuum contactor which opens and interrupts the primary power. The PFL
Mitigation of PID in commercial PV modules using current interruption method
NASA Astrophysics Data System (ADS)
Bora, Birinchi; Oh, Jaewon; Tatapudi, Sai; Sastry, Oruganty S.; Kumar, Rajesh; Prasad, Basudev; Tamizhmani, Govindasamy
2017-08-01
Potential-induced degradation (PID) is known to have a very severe effect on the reliability of PV modules. PID is caused due to the leakage of current from the cell circuit to the grounded frame under humid conditions of high voltage photovoltaic (PV) systems. There are multiple paths for the current leakage. The most dominant leakage path is from the cell to the frame through encapsulant, glass bulk and glass surface. This dominant path can be prevented by interrupting the electrical conductivity at the glass surface. In our previous works related to this topic, we demonstrated the effectiveness of glass surface conductivity interruption technique using one-cell PV coupons. In this work, we demonstrate the effectiveness of this technique using a full size commercial module susceptible to PID. The interruption of surface conductivity of the commercial module was achieved by attaching a narrow, thin flexible glass strips, from Corning, called Willow Glass on the glass surface along the inner edges of the frame. The flexible glass strip was attached to the module glass surface by heating the glass strip with an ionomer adhesive underneath using a handheld heat gun. The PID stress test was performed at 60°C and 85% RH for 96 hours at -600 V. Pre- and post-PID characterizations including I-V and electroluminescence were carried out to determine the performance loss and affected cell areas. This work demonstrates that the PID issue can be effectively addressed by using this current interruption technique. An important benefit of this approach is that this interruption technique can be applied after manufacturing the modules and after installing the modules in the field as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2014-07-01
Vacuum science and technology has made vital contributions in high technology areas like space, high energy particle accelerators, plasma devices, pulse power, electronics, vacuum interrupters, thin films, melting and refining of metals/alloys, extraction and processing of advanced materials. Vacuum discharges, vacuum arc physics and technology and various applications towards vacuum interrupters, pulse power and particle accelerator are the main themes for this symposium. Papers relevant to INIS are indexed separately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2014-07-01
Vacuum science and technology has made vital contributions in high technology areas like space, high energy particle accelerators, plasma devices, pulse power, electronics, vacuum interrupters, thin films, melting and refining of metals/alloys, extraction and processing of advanced materials. Vacuum discharges, vacuum arc physics and technology and various applications towards vacuum interrupters, pulse power and particle accelerator are the main themes for this symposium. Papers relevant to INIS are indexed separately.
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
30 CFR 18.54 - High-voltage continuous mining machines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Design Requirements § 18.54 High-voltage continuous mining machines. (a) Separation of high... removed. (c) Circuit-interrupting devices. Circuit-interrupting devices must be designed and installed to... ground. (e) Onboard ungrounded, three-phase power circuit. A continuous mining machine designed with an...
18 CFR 284.9 - Interruptible transportation service.
Code of Federal Regulations, 2010 CFR
2010-04-01
... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...
18 CFR 284.9 - Interruptible transportation service.
Code of Federal Regulations, 2014 CFR
2014-04-01
... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...
18 CFR 284.9 - Interruptible transportation service.
Code of Federal Regulations, 2011 CFR
2011-04-01
... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...
18 CFR 284.9 - Interruptible transportation service.
Code of Federal Regulations, 2012 CFR
2012-04-01
... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...
18 CFR 284.9 - Interruptible transportation service.
Code of Federal Regulations, 2013 CFR
2013-04-01
... transportation service. 284.9 Section 284.9 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES General Provisions and Conditions § 284.9 Interruptible transportation service. (a...
Collinge, Cory; Reddix, Robert
2011-02-01
Negative pressure wound therapy (NPWT) using the Vacuum Assisted Closure system is an invaluable tool for use on patients with complex limb and soft tissue problems. Recently, the manufacturer (Kinetic Concepts, Inc, San Antonio, TX) made significant modifications to the NPWT platform, including computer software, battery, alarming systems, electric cord and plug apparatus, and others. Since these modifications, we have seen several cases in which the NPWT device has powered off resulting in an unrecognized interruption of therapy. We sought to evaluate the conditions and clinical effects, if any, to orthopaedic trauma patients who experienced an interruption of NPWT therapy when the device powers off. Retrospective study of consecutive patients. Two neighboring regional trauma centers. One hundred twenty-three consecutive orthopaedic trauma patients treated with NPWT by two orthopaedic trauma surgeons between May and November 2008. Patient/injury, treatment, and perioperative clinical outcomes data (with emphasis on wound complications such as infection, graft loss, and unscheduled surgery) were collected from medical records and wound care databases. Twelve patients (10%) had problems with the NPWT device powering off causing an unrecognized interruption of therapy. Eleven patients underwent early (less than 6 hours) wound débridement and reapplication of NPWT after detection, of which nine required unplanned surgery. Seven of the 12 patients recognized as having failed NPWT of this type ultimately experienced wound complications, including five deep infections and both patients being treated with an Integra graft (loss of graft). We have seen substantial problems in orthopaedic trauma patients treated with the NPWT, in which the device has powered off resulting in an unrecognized interruption of therapy. This has resulted in atypically unhealthy-appearing wounds, unplanned surgeries for débridement, and most importantly, an increased incidence of wound complications, including infection and graft loss (P < 0.05).
Zhang, Fang; Wagner, Anita K; Ross-Degnan, Dennis
2011-11-01
Interrupted time series is a strong quasi-experimental research design to evaluate the impacts of health policy interventions. Using simulation methods, we estimated the power requirements for interrupted time series studies under various scenarios. Simulations were conducted to estimate the power of segmented autoregressive (AR) error models when autocorrelation ranged from -0.9 to 0.9 and effect size was 0.5, 1.0, and 2.0, investigating balanced and unbalanced numbers of time periods before and after an intervention. Simple scenarios of autoregressive conditional heteroskedasticity (ARCH) models were also explored. For AR models, power increased when sample size or effect size increased, and tended to decrease when autocorrelation increased. Compared with a balanced number of study periods before and after an intervention, designs with unbalanced numbers of periods had less power, although that was not the case for ARCH models. The power to detect effect size 1.0 appeared to be reasonable for many practical applications with a moderate or large number of time points in the study equally divided around the intervention. Investigators should be cautious when the expected effect size is small or the number of time points is small. We recommend conducting various simulations before investigation. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ouriev, Boris; Windhab, Erich; Braun, Peter; Birkhofer, Beat
2004-10-01
In-line visualization and on-line characterization of nontransparent fluids becomes an important subject for process development in food and nonfood industries. In our work, a noninvasive Doppler ultrasound-based technique is introduced. Such a technique is applied for investigation of nonstationary flow in the chocolate precrystallization process. Unstable flow conditions were induced by abrupt flow interruption and were followed up by strong flow pulsations in the piping system. While relying on available process information, such as absolute pressures and temperatures, no analyses of flow conditions or characterization of suspension properties could possibly be done. It is obvious that chocolate flow properties are sensitive to flow boundary conditions. Therefore, it becomes essential to perform reliable structure state monitoring and particularly in application to nonstationary flow processes. Such flow instabilities in chocolate processing can often lead to failed product quality with interruption of the mainstream production. As will be discussed, a combination of flow velocity profiles, on-line fit into flow profiles, and pressure difference measurement are sufficient for reliable analyses of fluid properties and flow boundary conditions as well as monitoring of the flow state. Analyses of the flow state and flow properties of chocolate suspension are based on on-line measurement of one-dimensional velocity profiles across the flow channel and their on-line characterization with the power-law model. Conclusions about flow boundary conditions were drawn from a calculated velocity standard mean deviation, the parameters of power-law fit into velocity profiles, and volumetric flow rate information.
Sassi, C G; Cameli, M; Dokollari, A; Diciolla, F; Scolletta, S; Ricci, C; Lucatelli, P; Mondillo, S; Maccherini, M
2017-05-01
There are limited clinical reports concerning internal power cable fixing in left ventricular assist device (L-VAD) patients. Actually there are no reports in the literature about Jarvik 2000 internal cable repair. We show the first description of a technique for surgical reparation of such a fatal complication. The patient was a 62-year-old woman who had L-VAD implantation (Jarvik 2000) with outflow graft apposition in descending thoracic aorta through left thoracotomy access, in 2009. She arrived urgently on January 25, 2014 for Jarvik 2000 dysfunction correlated with head movements. The neck X-rays revealed the rupture of one of the nine power cables located inside the neck and the damaging of two more cables nearby to be ruptured. On the same day she got pump failure due to the final interruption of the remaining two cables, we were obliged to install femoro-femoral extracorporeal membrane oxygenation (ECMO) assistance, to repair the power cables, approaching them through a pacemaker extension cable. The L-VAD outflow was occluded with vascular ball occluder inserted via right axillary artery under fluoroscopy before ECMO installation. At the end the ECMO assistance was interrupted and the Jarvik 2000 was turned back on. The patient was dismissed from the hospital 12 days after the procedure. At the moment the international literature is poor regarding this issue. This case provides evidence that in emergency conditions ECMO assistance is mandatory and a hybrid surgical and radiological approach could help to repair the damage in safe conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamachi La Commare, Kristina
Metrics for reliability, such as the frequency and duration of power interruptions, have been reported by electric utilities for many years. This study examines current utility practices for collecting and reporting electricity reliability information and discusses challenges that arise in assessing reliability because of differences among these practices. The study is based on reliability information for year 2006 reported by 123 utilities in 37 states representing over 60percent of total U.S. electricity sales. We quantify the effects that inconsistencies among current utility reporting practices have on comparisons of System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Indexmore » (SAIFI) reported by utilities. We recommend immediate adoption of IEEE Std. 1366-2003 as a consistent method for measuring and reporting reliability statistics.« less
NASA Astrophysics Data System (ADS)
Gebhardt, Pierre; Wehner, Jakob; Weissler, Bjoern; Frach, Thomas; Marsden, Paul K.; Schulz, Volkmar
2015-06-01
Devices aiming at combined Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) to enable simultaneous PET/MR image acquisition have to fulfill demanding requirements to avoid mutual magneticas well as electromagnetic-field-related interferences which lead to image quality degradation. Particularly Radio-Frequency (RF)-field-related interferences between PET and MRI may lead to MRI SNR reduction, thereby deteriorating MR image quality. RF shielding of PET electronics is therefore commonly applied to reduce RF emission and lower the potential coupling into MRI RF coil(s). However, shields introduce eddy-current-induced MRI field distortions and should thus be minimized or ideally omitted. Although the MRI noise floor increase caused by a PET system might be acceptable for many MRI applications, some MRI protocols, such as fast or high-resolution MRI scans, typically suffer from low SNR and might need more attention regarding RF silence to preserve the intrinsic MRI SNR. For such cases, we propose RESCUE, an MRI-synchronously-gated PET data acquisition technique: By interrupting the PET acquisition during MR signal receive phases, PET-related RF emission may be minimized, leading to MRI SNR preservation. Our PET insert Hyperion IID using Philips Digital Photon Counting (DPC) sensors serves as the platform to demonstrate RESCUE. To make the DPC sensor suitable for RESCUE to be applied for many MRI sequences with acquisition time windows in the range of a few milliseconds, we present in this paper a new technique which enables rapid DPC sensor operation interruption by dramatically lowering the overhead time to interrupt and restart the sensor operation. Procedures to enter and leave gated PET data acquisition may imply sensitivity losses which add to the ones occurring during MRI RF acquisition. For the case of our PET insert, the new DPC quick-interruption technique yields a PET sensitivity loss reduction by a factor of 78 when compared to the loss introduced with the standard start/stop procedure. For instance, PET sensitivity losses related to overhead time are 2.9% in addition to the loss related to PET gating being equal to the MRI RF acquisition duty cycle (14.7%) for an exemplary T1-weighted 3D-FFE MRI sequence. MRI SNR measurement results obtained with one Singles Detection Module (SDM) using no RF shield demonstrate a noise floor reduction by a factor of 2.1, getting close to the noise floor level of the SNR reference scan (SDM off-powered) when RESCUE was active.
2009-05-26
Interrupt HW Interrupt DFS Dynamic Frequency Selection TPC Transmit Power Control r- MPX Hub ! i j I Power Supply Init/Reset A/D...values of several variables: from IN_0_DAT when the Mailbox forwards data supplied by Client 0, from OUT1DAT when the conditions on the ready flags are...logically implies ip y 0, and also <j> logically implies ip y <p; (b) if for all i we have that cj>t+1 is of the form (p% y ip, then the chain
Modelling voltage sag mitigation using dynamic voltage restorer and analyzing power quality issue
NASA Astrophysics Data System (ADS)
Ismail, Nor Laili; Hidzir, Hizrin Dayana Mohd; Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Ibrahim, Pungut; Ali, Che Ku Muhammad Sabri Che Ku
2018-02-01
Power quality problem which are arise due to a fault or a pulsed load can have caused an interruption of critical load. The modern power systems are becoming more sensitive to the quality of the power supplied by the utility company. Voltage sags and swells, flicker, interruptions, harmonic distortion and other distortion to the sinusoidal waveform are the examples of the power quality problems. The most affected due to these problems is industrial customers who use a lot of sensitive equipment. There has suffered a huge loss to these problems. Resulting of broken or damage equipment if voltage sag exceeds the sensitive threshold of the equipment. Thus, device such as Static Synchronous Compensator (STATCOM) and Dynamic Voltage Restorer (DVR) has been created to solve this problem among users. DVR is a custom power device that most effective and efficient. This paper intended to report the DVR operations during voltage sag compensation.
NASA Astrophysics Data System (ADS)
Cheng, Shaoyong; Xiu, Shixin; Wang, Jimei; Shen, Zhengchao
2006-11-01
The greenhouse effect of SF6 is a great concern today. The development of high voltage vacuum circuit breakers becomes more important. The vacuum circuit breaker has minimum pollution to the environment. The vacuum interrupter is the key part of a vacuum circuit breaker. The interrupting characteristics in vacuum and arc-controlling technique are the main problems to be solved for a longer gap distance in developing high voltage vacuum interrupters. To understand the vacuum arc characteristics and provide effective technique to control vacuum arc in a long gap distance, the arc mode transition of a cup-type axial magnetic field electrode is observed by a high-speed charge coupled device (CCD) video camera under different gap distances while the arc voltage and arc current are recorded. The controlling ability of the axial magnetic field on vacuum arc obviously decreases when the gap distance is longer than 40 mm. The noise components and mean value of the arc voltage significantly increase. The effective method for controlling the vacuum arc characteristics is provided by long gap distances based on the test results. The test results can be used as a reference to develop high voltage and large capacity vacuum interrupters.
NASA Astrophysics Data System (ADS)
Niwa, Yoshimitsu; Kaneko, Eiji
Vacuum circuit breakers (VCB) have been widely used for power distribution systems. Vacuum Interrupters, which are the current interruption unit, have been increased its interruption capability with the development of vacuum arc control technology by magnetic field. There are three major type electrodes: disk shaped electrodes, radial magnetic field electrodes, axial magnetic field (AMF) electrodes. In the disk shaped electrode, the vacuum arc between the electrodes is not controlled. In the AMF electrode, the vacuum arc is diffused and stabilized by an axial magnetic field, which is parallel to the arc current. In the last type of electrodes, the vacuum arc column is rotated by magnetic force generated by the current flowing in the electrodes. The interruption current and the voltage of one break VCB is increased to 100 kA, 144 kV respectively. This paper describes basic configurations and functions of VCB, vacuum arc control technology in vacuum interrupters, recent researches and applications of VCB.
Numerical modeling of high-voltage circuit breaker arcs and their interraction with the power system
NASA Astrophysics Data System (ADS)
Orama, Lionel R.
In this work the interaction between series connected gas and vacuum circuit breaker arcs has been studied. The breakdown phenomena in vacuum interrupters during the post arc current period have been of special interest. Numerical models of gas and vacuum arcs were developed in the form of black box models. Especially, the vacuum post arc model was implemented by combining the existing transition model with an ion density function and expressions for the breakdown mechanisms. The test series studied reflect that for electric fields on the order of 10sp7V/m over the anode, the breakdown of the vacuum gap can result from a combination of both thermal and electrical stresses. For a particular vacuum device, the vacuum model helps to find the interruption limits of the electric field and power density over the anode. The series connection of gas and vacuum interrupters always performs better than the single gas device. Moreover, to take advantage of the good characteristics of both devices, the time between the current zero crossing in each interrupter can be changed. This current zero synchronization is controlled by changing the capacitance in parallel to the gas device. This gas/vacuum interrupter is suitable for interruption of very stressful short circuits in which the product of the dI/dt before current zero and the dV/dt after current zero is very high. Also, a single SF6 interrupter can be replaced by an air circuit breaker of the same voltage rating in series with a vacuum device without compromising the good performance of the SF6 device. Conceptually, a series connected vacuum device can be used for high voltage applications with equal distribution of electrical stresses between the individual interrupters. The equalization can be made by a sequential opening of the individual contact pairs, beginning with the interruptors that are closer to ground potential. This could eliminate the use of grading capacitors.
Habibi, E; Zare, M; Barkhordari, A; Mirmohammadi, Sj; Halvani, Ghh
2008-12-28
The aim of this study was to identify the hazards, evaluate their risk factors and determine the measure for promotion of the process and reduction of accidents in the chemical unit of the power station. In this case and qualitative study, HAZOP technique was used to recognize the hazards and problems of operations on the chemical section at power station. Totally, 126 deviations were documented with various causes and consequences. Ranking and evaluation of identified risks indicate that the majority of deviations were categorized as "acceptable" and less than half of that were "unacceptable". The highest calculated risk level (1B) related to both the interruption of acid entry to the discharge pumps and an increased density of the acid. About 27% of the deviations had the lowest risk level (4B). The identification of hazards by HAZOP indicates that it could, systemically, assess and criticize the process of consumption or production of acid and alkali in the chemical unit of power plant.
ERIC Educational Resources Information Center
Calsyn, Robert J.; And Others
1977-01-01
After arguing that treatment programs for the elderly need to be evaluated with better research designs, the authors illustrate how interrupted time series analysis can be used to evaluate programs for the elderly when random assignment to experimental and control groups is not possible. (Author)
Nishihara, Kyoko; Horiuchi, Shigeko; Eto, Hiromi; Uchida, Sunao; Honda, Makoto
2004-09-23
The power spectra of night sleep EEGs of 12 breast-feeding 9-13 week postpartum mothers were analyzed and compared with those of 12 non-pregnant women. The power spectra in the delta and theta frequency range during NREM sleep for breast-feeding mothers were significantly higher than those for non-pregnant women. In addition, the all-night sleep patterns of the mothers were classified into two groups - interrupted sleep due to taking care of their infants and non-interrupted sleep - in order to observe the influence of partial sleep deprivation. The power spectra in the delta and theta frequency range were not significantly different between them. This result suggests that increased delta and theta power spectra during postpartum sleep do not result from partial sleep deprivation. The role of prolactin in breast-feeding mothers' sleep is also discussed.
HIV models for treatment interruption: Adaptation and comparison
NASA Astrophysics Data System (ADS)
Hillmann, Andreas; Crane, Martin; Ruskin, Heather J.
2017-10-01
In recent years, Antiretroviral Therapy (ART) has become commonplace for treating HIV infections, although a cure remains elusive, given reservoirs of replicating latently-infected cells, which are resistant to normal treatment regimes. Treatment interruptions, whether ad hoc or structured, are known to cause a rapid increase in viral production to detectable levels, but numerous clinical trials remain inconclusive on the dangers inherent in this resurgence. In consequence, interest in examining interruption strategies has recently been rekindled. This overview considers modelling approaches, which have been used to explore the issue of treatment interruption. We highlight their purpose and the formalisms employed and examine ways in which clinical data have been used. Implementation of selected models is demonstrated, illustrative examples provided and model performance compared for these cases. Possible extensions to bottom-up modelling techniques for treatment interruptions are briefly discussed.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Reports by natural gas..., NATURAL GAS ACT STATEMENTS AND REPORTS (SCHEDULES) § 260.9 Reports by natural gas pipeline companies on service interruptions and damage to facilities. (a)(1) Every natural gas company must report to the...
Raman, Hari S; Santanam, Lakshmi; Vellimana, Ananth K; Drzymala, Robert E; Tsien, Christina I; Zipfel, Gregory J
2018-02-17
Gamma Knife radiosurgery is an established technique for non-urgent treatment of various intracranial pathologies. Intra-procedural dislodgement of the stereotactic frame is an uncommon occurrence that could lead to abortion of ongoing treatment and necessitate more invasive treatment strategies. In this case report, we describe a novel method for resumption of Gamma Knife treatment after an unplanned intra-procedural interruption. The case example involves a radiosurgical treatment of a Spetzler-Martin grade I arteriovenous malformation. Our technique involves integration of scans and coordinate systems from two imaging sessions using the composite isodose line to resolve translational differences, thereby limiting delivery of remaining shots to the untreated region of the lesion. MRI follow-up at 13 months showed a reduction in the nidus size with no evidence of any radiation injury to the surrounding brain parenchyma. We believe this technique will allow care teams to effectively salvage interrupted Gamma Knife procedures and reduce progression to more invasive treatment options.
14 CFR 29.812 - Emergency lighting.
Code of Federal Regulations, 2010 CFR
2010-01-01
... lighting system, they may be recharged from the rotorcraft's main electrical power system provided the... power supply independent of the main lighting system must be installed to— (1) Illuminate each passenger... upon interruption of the rotorcraft's normal electric power. (d) Any means required to assist the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Divan, Deepak; Brumsickle, William; Eto, Joseph
2003-04-01
This report describes a new approach for collecting information on power quality and reliability and making it available in the public domain. Making this information readily available in a form that is meaningful to electricity consumers is necessary for enabling more informed private and public decisions regarding electricity reliability. The system dramatically reduces the cost (and expertise) needed for customers to obtain information on the most significant power quality events, called voltage sags and interruptions. The system also offers widespread access to information on power quality collected from multiple sites and the potential for capturing information on the impacts ofmore » power quality problems, together enabling a wide variety of analysis and benchmarking to improve system reliability. Six case studies demonstrate selected functionality and capabilities of the system, including: Linking measured power quality events to process interruption and downtime; Demonstrating the ability to correlate events recorded by multiple monitors to narrow and confirm the causes of power quality events; and Benchmarking power quality and reliability on a firm and regional basis.« less
Estimating Economic and Logistic Utility of Connecting to Unreliable Power Grids
2016-06-17
the most unreliable host nation grids almost always have a higher availability than solar photovoltaics ( PV ), which for most parts of the world will...like solar , and still design a facility energy architecture that benefits from that source when available. Index Terms—facilities management, energy...Maintenance PV Photovoltaic SAIDI System Average Interruption Duration Index SAIFI System Average Interruption Frequency Index SHP Simplified Host
Stoffels, M; Simon, S; Nikolic, P G; Stoller, P; Carstensen, J
2017-03-01
High-voltage gas circuit breakers, which play an important role in the operation and protection of the power grid, function by drawing an arc between two contacts and then extinguishing it by cooling it using a transonic gas flow. Improving the design of circuit breakers requires an understanding of the physical processes in the interruption of the arc, particularly during the zero crossing of the alternating current (the point in time when the arc can be interrupted). Most diagnostic techniques currently available focus on measurement of current, voltage, and gas pressure at defined locations. However, these integral properties do not give sufficient insight into the arc physics. To understand the current interruption process, spatially resolved information about the density, temperature, and conductivity of the arc and surrounding gas flow is needed. Owing to the three-dimensional, unstable nature of the arc in a circuit breaker, especially near current zero, a spatially resolved, tomographic diagnostic technique is required that is capable of freezing the rapid, transient behavior and that is insensitive to the vibrations and electromagnetic interference inherent in the interruption of short-circuit current arcs. Here a new measurement system, based on background-oriented schlieren (BOS) imaging, is presented and assessed. BOS imaging using four beams consisting of white light sources, a background pattern, imaging optics, and a camera permits measurement of the line-of-sight integrated refractive index. Tomographic reconstruction is used to determine the three-dimensional, spatially resolved index of refraction distribution that in turn is used to calculate the density. The quantitative accuracy of a single beam of the BOS setup is verified by using a calibration lens with a known focal length. The ability of the tomographic reconstruction to detect asymmetric features of the arc and surrounding gas flow is assessed semiquantitatively using a nozzle that generates two gas jets, as described in [Exp. Fluids43, 241 (2007)EXFLDU0723-486410.1007/s00348-007-0331-1]. Experiments using a simple model of a circuit breaker, which provides optical access to an ∼1 kA arc that burns between two contacts and is blown through a nozzle system by synthetic air from a high pressure reservoir, are also described. The density in the decaying arc and surrounding gas flow is reconstructed, and the limitations of the technique, which are related to the temporal and spatial resolution, are addressed.
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature and pressure sensors, outdoor enclosure, electrical power supply, control devices and operator... rate cut-off; operation following power interruptions; effect of variations in power line voltage... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted...
Healthy satellites provide quality service
NASA Astrophysics Data System (ADS)
Margittai, Paul
The procedures used by Telesat Canada to ensure the performance of Anik satellites is described. At the Satellite Telemetry, Tracking and Command station, each Anik satellite has its own dedicated antenna. Telemetered information from the satellites is received, processed and forwarded to the Satellite Control Center. There the satellite controllers issue all commands to the satellites, and continually monitor the telemetered data. These data, describing the state of health of the satellites, are then analyzed by engineering specialists. The satellites are held in their precise orbital positions by means of specially developed software. The Anik C and D satellites employ travelling wave tube amplifiers (TWTAs) in the transpounder channels. The TWTA saturated flux density (SFD) and equivalent isotropic radiated power (EIRP) are regularly measured and their trends scrutinized. This ensures that customers receive the radio frequency power needed for high-quality service. The satellite electrical power is supplied by the solar cell array and batteries. Power system performance is evaluated regularly to ensure that power is available to operate the required number of TWTAs. In addition to rain-fades, short service interruptions can be caused by high voltage trip-offs of TWTAs, and by electrostatic discharge related anomalies. To minimize these interruptions, Telesat ensures that the satellite controllers are fully trained and prepared for any eventuality, and the relevant operational procedures are continually refined. A fully trained staff of satellite controllers keep interruptions caused by high voltage trip-offs of TWTAs and by electrostatic discharge to a minimum.
Langley Research Center Utility Risk from Future Climate Change
NASA Technical Reports Server (NTRS)
De Young, Russell J.; Ganoe, Rene
2015-01-01
The successful operation of NASA Langley Research Center (LaRC) depends on services provided by several public utility companies. These include Newport News Waterworks, Dominion Virginia Power, Virginia Natural Gas and Hampton Roads Sanitation District. LaRC's plan to respond to future climate change should take into account how these companies plan to avoid interruption of services while minimizing cost to the customers. This report summarizes our findings from publicly available documents on how each company plans to respond. This will form the basis for future planning for the Center. Our preliminary findings show that flooding and severe storms could interrupt service from the Waterworks and Sanitation District but the potential is low due to plans in place to address climate change on their system. Virginia Natural Gas supplies energy to produce steam but most current steam comes from the Hampton trash burning plant, thus interruption risk is low. Dominion Virginia Power does not address climate change impacts on their system in their public reports. The potential interruption risk is considered to be medium. The Hampton Roads Sanitation District is projecting a major upgrade of their system to mitigate clean water inflow and infiltration. This will reduce infiltration and avoid overloading the pump stations and treatment plants.
NASA Technical Reports Server (NTRS)
Ludwig, Kimberly; Mackin, Michael; Wright, Theodore
1991-01-01
The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.
Fan, John C. C.; Tsaur, Bor-Yeu; Gale, Ronald P.; Davis, Frances M.
1992-02-25
Dislocation densities are reduced in growing semiconductors from the vapor phase by employing a technique of interrupting growth, cooling the layer so far deposited, and then repeating the process until a high quality active top layer is achieved. The method of interrupted growth, coupled with thermal cycling, permits dislocations to be trapped in the initial stages of epitaxial growth.
Fan, John C. C.; Tsaur, Bor-Yeu; Gale, Ronald P.; Davis, Frances M.
1986-12-30
Dislocation densities are reduced in growing semiconductors from the vapor phase by employing a technique of interrupting growth, cooling the layer so far deposited, and then repeating the process until a high quality active top layer is achieved. The method of interrupted growth, coupled with thermal cycling, permits dislocations to be trapped in the initial stages of epitaxial growth.
Chemical Safety Alert: Chemical Accidents from Electric Power Outages
Incident data from the National Response Center (NRC) shows that during 2000 there were about 240 chemical releases reported due to an electric power interruption, as well as resumption/restart; only a few were related to planned rolling blackouts.
Power transfer for rotating medical machine.
Sofia, A; Tavilla, A C; Gardenghi, R; Nicolis, D; Stefanini, I
2016-08-01
Very often biological tissues need to be treated inside of a biomedical centrifuge even during the centrifugation step without process interruption. In this paper an advantageous energy transfer method capable of providing sufficient electric power for the rotating and active part is presented.
NASA Astrophysics Data System (ADS)
Hallman, Sydney N.; Huck, Robert C.; Sluss, James J.
2016-05-01
The use of a wireless charging system for small, unmanned aircraft system applications is useful for both military and commercial consumers. An efficient way to keep the aircraft's batteries charged without interrupting flight would be highly marketable. While the general concepts behind highly resonant wireless power transfer are discussed in a few publications, the details behind the system designs are not available even in academic journals, especially in relation to avionics. Combining a highly resonant charging system with a solar panel charging system can produce enough power to extend the flight time of a small, unmanned aircraft system without interruption. This paper provides an overview of a few of the wireless-charging technologies currently available and outlines a preliminary design for an aircraft-mounted battery charging system.
ERIC Educational Resources Information Center
Huitema, Bradley E.; McKean, Joseph W.
2007-01-01
Regression models used in the analysis of interrupted time-series designs assume statistically independent errors. Four methods of evaluating this assumption are the Durbin-Watson (D-W), Huitema-McKean (H-M), Box-Pierce (B-P), and Ljung-Box (L-B) tests. These tests were compared with respect to Type I error and power under a wide variety of error…
Early Oscillation Detection for DC/DC Converter Fault Diagnosis
NASA Technical Reports Server (NTRS)
Wang, Bright L.
2011-01-01
The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.
Applying social network analysis to the examination of interruptions in healthcare.
McCurdie, Tara; Sanderson, Penelope; Aitken, Leanne M
2018-02-01
Examinations of interruptions in healthcare often focus on a single clinical discipline, and solutions are targeted accordingly. This approach does not take into account the inter-disciplinary dependencies and other sociotechnical aspects that make up the healthcare work system, and suggested solutions may not meet the needs of all stakeholders. In this article a sociotechnical systems perspective is used to uncover the interdependencies between 16 unique work roles that result in interruptions in an intensive care unit (ICU). By applying social network analysis techniques to data collected using the Dual Perspectives Method, we identified targeted systems-based interventions that may reduce unnecessary interruptions while avoiding unintended consequences that impose additional burden on ICU staff. The rich insights gained into the interruptive communication patterns in the ICU work system stand in contrast to findings that would have otherwise been obtained by focusing only on a single clinical discipline or a single perspective. Copyright © 2017. Published by Elsevier Ltd.
Ziai, Setareh; Rootman, David S; Slomovic, Allan R; Chan, Clara C
2013-11-01
To describe a surgical technique to repair Boston type 1 keratoprosthesis (KPro)-related corneal melts. Technique description and review of 3 representative cases. After harvesting the buccal mucosa from the patient's inner lower lip, the exposed area of the KPro back plate is prepared for repair by adequate exposure and removal of necrotic tissue. The area is then covered with a lamellar patch of cornea secured in place with interrupted 10-0 nylon sutures, followed by a thin layer of buccal mucosa secured in place with interrupted 8-0 vicryl sutures. This technique provides surgeons with a method to repair KPro-related corneal melts when there is a conjunctival deficiency.
Szúcs, G; Tóth, I; Bráth, E; Gyáni, K; Miko, I
2001-08-01
We have good results with telescopic anastomosis technique in partial oesophagectomies and gastrectomies. As we could not find data about the healing process of telescopic anastomoses so we started experimenting. Inside pressure tolerance was examined immediately after performing anastomoses by measuring the bursting pressure using the organs of pigs slaughtered in the meat industry. Both oesophago-gastrostomies and oesophago-jejunostomies were performed with telescopic, single layer interrupted, single layer continuous, double layer interrupted and double layer continuous-interrupted technique, 9 of each anastomosis. A series of oesophago-jejunostomies were performed with EEA stapler. 99 anastomoses of 11 types were investigated. We found, that the inner pressure tolerance of telescopic oesophago-gastrostomy is better than any other single layer type variant. On the other hand the double layer type variants have much better pressure tolerance than the telescopic and other two type single layer anastomoses. The difference is statistically significant. In oesophago-jejunostomies the pressure tolerance of telescopic anastomosis is better than of the single layer interrupted type but the difference between the telescopic and single layer continuous type anastomoses is not significant. The pressure tolerance of double layer anastomosis is higher than the telescopic one but the difference is significant only in the continuous-interrupted type. The inner pressure tolerance of telescopic and EEA stapler anastomoses are equal. The investigation of additional features in anastomosis healing is in progress.
B. W. Butler; T. Wallace; J. Hogge
2015-01-01
Towers and poles supporting power transmission and telecommunication lines have collapsed due to heating from wildland fires. Such occurrences have led to interruptions in power or communication in large municipal areas with associated social and political implications as well as increased immediate danger to humans. Vegetation clearance standards for overhead...
B. W. Butler; J. Webb; J. Hogge; T. Wallace
2015-01-01
Towers and poles supporting power transmission and telecommunication lines have collapsed due to heating from wildland fires. Such occurrences have led to interruptions in power or communication in large municipal areas with associated social and political implications as well as increased immediate danger to humans. Unfortunately, no studies address the question of...
The Breakdown Characteristics of the Silicone Oil for Electric Power Apparatus
NASA Astrophysics Data System (ADS)
Yoshida, Hisashi; Yanabu, Satoru
The basic breakdown characteristics of the silicone oil as an insulating medium was studied with aim of realization of electric power apparatus which may be considered to be SF6 free and flame-retarding. As the first step, the impulse breakdown characteristics was measured with three kinds of electrodes whose electric field distributions differed. The breakdown characteristics in silicone oil was explained in relation to stressed oil volume (SOV) and the breakdown stress. At the second step the surface breakdown characteristic for impulse voltage was measured with two kinds of insulators which was set to between plane electrodes. The surface breakdown characteristic for impulse voltage was explained in relation to the ratio of the relative permittivity of oil and insulator. And on the third step, the breakdown characteristics of oil gap after interrupting small capacitive current was studied. In this experiment, the disconnecting switch to interrupt capacitive current was simulated by oil gap after interrupting impulse current, and to measure breakdown characteristics the high impulse voltage was subsequently applied. The breakdown stress in silicone oil after application of impulse current was discussed for insulation recovery characteristics.
Large-scale data analysis of power grid resilience across multiple US service regions
NASA Astrophysics Data System (ADS)
Ji, Chuanyi; Wei, Yun; Mei, Henry; Calzada, Jorge; Carey, Matthew; Church, Steve; Hayes, Timothy; Nugent, Brian; Stella, Gregory; Wallace, Matthew; White, Joe; Wilcox, Robert
2016-05-01
Severe weather events frequently result in large-scale power failures, affecting millions of people for extended durations. However, the lack of comprehensive, detailed failure and recovery data has impeded large-scale resilience studies. Here, we analyse data from four major service regions representing Upstate New York during Super Storm Sandy and daily operations. Using non-stationary spatiotemporal random processes that relate infrastructural failures to recoveries and cost, our data analysis shows that local power failures have a disproportionally large non-local impact on people (that is, the top 20% of failures interrupted 84% of services to customers). A large number (89%) of small failures, represented by the bottom 34% of customers and commonplace devices, resulted in 56% of the total cost of 28 million customer interruption hours. Our study shows that extreme weather does not cause, but rather exacerbates, existing vulnerabilities, which are obscured in daily operations.
The interrupted serosubmucosal anastomosis - still the gold standard.
Leslie, A; Steele, R J C
2003-07-01
The single-layer appositional serosubmucosal anastomosis is a well established technique and appears to have a favourable record. Over a 15-year period the senior author of this paper has performed or directly supervised 553 anastomoses using this technique. This report describes the results of these operations, the results of stapled anastomoses carried out during the same period and discusses the utility of the handsewn technique. From August 1986 to July 2001, 553 intestinal anastomoses in 550 patients were fashioned using single-layer, interrupted serosubmucosal 3/0 braided polyamide and 131 anastomoses in 131 patients were performed using a circular anastomosing stapler. One anastomotic leakage occurred in the group of patients whose anastomosis was handsewn (0.2%) and 11 leaks occurred in those who had a stapled anastomoses (8.4%). The mortality rate in each group was similar (2% and 2.3%, respectively). There were no deaths attributable to anastomotic dehiscence in either group. In this prospectively audited series of 553 handsewn anastomoses the leakage rate was 0.2%. These results compare favourably with other published series and continue to support a single layer of interrupted serosubmucosal sutures as the gold standard for anastomoses involving the large or small bowel.
Methods for maintaining the continuity of power supply in hospitals
NASA Astrophysics Data System (ADS)
Mihut, V. V.; Panoiu, M.; Panoiu, C.; Baciu, I.
2018-01-01
This paper presents alternative solutions to ensure power supply of critical consumer, such hospitals. In a hospital it is extremely important to have a power supply without any interruption. This is the reason of the using various solutions that ensure continuity of power supply. In this paper it is presented a solution used in a hospital in Romania. Here is used a generator controlled by microprocessor capable of taking over power supply in case there are problems with power supply from the national power grid.
Simple circuit monitors "third wire" in ac lines
NASA Technical Reports Server (NTRS)
Kojima, T. T.; Stuck, D. E.
1980-01-01
Device detects interruption of ground connection in three-wire electrical equipment and shuts off ac power to prevent shock hazard. Silicon-controlled rectifiers detect floating ground, and deenergize optoelectric relays thereby breaking power connections. Circuit could be incorporated into hand tools, appliances, and other electrical equipment.
18 CFR 39.4 - Funding of the Electric Reliability Organization.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Reliability Organization. 39.4 Section 39.4 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT RULES CONCERNING... interruption as it transitions from one method of funding to another. Any proposed transitional funding plan...
18 CFR 39.4 - Funding of the Electric Reliability Organization.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Reliability Organization. 39.4 Section 39.4 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT RULES CONCERNING... interruption as it transitions from one method of funding to another. Any proposed transitional funding plan...
18 CFR 39.4 - Funding of the Electric Reliability Organization.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Reliability Organization. 39.4 Section 39.4 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT RULES CONCERNING... interruption as it transitions from one method of funding to another. Any proposed transitional funding plan...
18 CFR 39.4 - Funding of the Electric Reliability Organization.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Reliability Organization. 39.4 Section 39.4 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT RULES CONCERNING... interruption as it transitions from one method of funding to another. Any proposed transitional funding plan...
Mechanical beam isolator for high-power laser systems
Post, Richard F.; Vann, Charles S.
1998-01-01
A mechanical beam isolator uses rod-shaped elements having a Gaussian configuration to interrupt the path of a beam of photons or particles when the time-scale of the needed interruption is of the order of a microsecond or less. One or more of these rods is mounted transversely to, and penetrates through, a rotating shaft supported by bearings. Owing to the Gaussian geometry of the rods, they are able to withstand much higher rotation speeds, without tensile failure, than rods having any other geometrical shape.
30 CFR 75.825 - Power centers.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., and be designed and installed as follows: (1) Rated for the maximum phase-to-phase voltage of the circuit; (2) Rated for the full-load current of the circuit that is supplied power through the device. (3... current of the circuit or causes the current to be interrupted automatically before the disconnecting...
Enhancing the quantum efficiency of InGaN yellow-green light-emitting diodes by growth interruption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Chunhua; Ma, Ziguang; Zhou, Junming
2014-08-18
We studied the effect of multiple interruptions during the quantum well growth on emission-efficiency enhancement of InGaN-based yellow-green light emitting diodes on c-plane sapphire substrate. The output power and dominant wavelength at 20 mA are 0.24 mW and 556.3 nm. High resolution x-ray diffraction, photoluminescence, and electroluminescence measurements demonstrate that efficiency enhancement could be partially attributed to crystal quality improvement of the active region resulted from reduced In clusters and relevant defects on the surface of InGaN layer by introducing interruptions. The less tilted energy band in the quantum well is also caused by the decrease of In-content gradient along c-axis resultedmore » from In segregation during the interruptions, which increases spatial overlap of electron-hole wavefunction and thus the internal quantum efficiency. The latter also leads to smaller blueshift of dominant wavelength with current increasing.« less
Generator powered electrically heated diesel particulate filter
Gonze, Eugene V; Paratore, Jr., Michael J
2014-03-18
A control circuit for a vehicle powertrain includes a switch that selectivity interrupts current flow between a first terminal and a second terminal. A first power source provides power to the first terminal and a second power source provides power to the second terminal and to a heater of a heated diesel particulate filter (DPF). The switch is opened during a DPF regeneration cycle to prevent the first power source from being loaded by the heater while the heater is energized.
NASA Technical Reports Server (NTRS)
Feagans, P. L.
1972-01-01
Electro-chemical grinding technique has rotation speed control, constant feed rates, and contour control. Hypersonic engine parts of nickel alloys can be almost 100% machined, keeping tool pressure at virtual zero. Technique eliminates galling and permits constant surface finish and burr-free interrupted cutting.
New Modulation Method and Control Strategies for Power Electronics Inverters
NASA Astrophysics Data System (ADS)
Aleenejad, Mohsen
The DC to AC power Converters (so-called Inverters) are widely used in industrial applications. The MLIs are becoming increasingly popular in industrial apparatus aimed at medium to high power conversion applications. In comparison to the conventional inverters, they feature superior characteristics such as lower total harmonic distortion (THD), higher efficiency, and lower switching voltage stress. Nevertheless, the superior characteristics come at the price of a more complex topology with an increased number of power electronic switches. The increased number of power electronics switches results in more complicated control strategies for the inverter. Moreover, as the number of power electronic switches increases, the chances of fault occurrence of the switches increases, and thus the inverter's reliability decreases. Due to the extreme monetary ramifications of the interruption of operation in commercial and industrial applications, high reliability for power inverters utilized in these sectors is critical. As a result, developing simple control strategies for normal and fault-tolerant operation of MLIs has always been an interesting topic for researchers in related areas. The purpose of this dissertation is to develop new control and fault-tolerant strategies for the multilevel power inverter. For the normal operation of the inverter, a new high switching frequency technique is developed. The proposed method extends the utilization of the dc link voltage while minimizing the dv/dt of the switches. In the event of a fault, the line voltages of the faulty inverters are unbalanced and cannot be applied to the 3-phase loads. For the faulty condition of the inverter, three novel fault-tolerant techniques are developed. The proposed fault-tolerant strategies generate balanced line voltages without bypassing any healthy and operative inverter element, makes better use of the inverter capacity and generates higher output voltage. These strategies exploit the advantages of the Selective Harmonic Elimination (SHE) and Space Vector Modulation (SVM) methods in conjunction with a slightly modified Fundamental Phase Shift Compensation (FPSC) technique to generate balanced voltages and manipulate voltage harmonics at the same time. The proposed strategies are applicable to several classes of MLIs with three or more voltage levels.
Sunlight Helps Laboratory Get Ready for Y2K
by the end of December to provide emergency electricity to the Site Entrance Building (SEB), which solar power if the supply of electricity from the local utility grid is interrupted. The solar generator failure disrupts electricity supplies. If a power failure should be protracted, a secondary propane backup
Monitoring the battery status for photovoltaic systems
NASA Astrophysics Data System (ADS)
Kim, Myungsoo; Hwang, Euijin
Photovoltaic power systems in Korea have been installed in remote islands where it is difficult to connect the utilities. Lead/acid batteries are used as an energy storage device for the stand-alone photovoltaic system. Hence, monitoring the battery status of photovoltaic systems is quite important to extend the total system service life. To monitor the state-of-charge of batteries, we adopted a current interrupt technique to measure the internal resistance of the battery. The internal resistance increases at the end of charge/discharge steps and also with cycles. The specific gravity of the electrolyte was measured in relation to the state-of-charge. A home-made optical hydrometer was utilized for automatic monitoring of the specific gravity. It is shown that the specific gravity and stratification increase with cycle number. One of the photovoltaic systems in a remote island, Ho-do, which has 90 kW peak power was checked for actual operational conditions such as solar generation, load, and battery status.
Reduction of a linear complex model for respiratory system during Airflow Interruption.
Jablonski, Ireneusz; Mroczka, Janusz
2010-01-01
The paper presents methodology of a complex model reduction to its simpler version - an identifiable inverse model. Its main tool is a numerical procedure of sensitivity analysis (structural and parametric) applied to the forward linear equivalent designed for the conditions of interrupter experiment. Final result - the reduced analog for the interrupter technique is especially worth of notice as it fills a major gap in occlusional measurements, which typically use simple, one- or two-element physical representations. Proposed electrical reduced circuit, being structural combination of resistive, inertial and elastic properties, can be perceived as a candidate for reliable reconstruction and quantification (in the time and frequency domain) of dynamical behavior of the respiratory system in response to a quasi-step excitation by valve closure.
Mechanical beam isolator for high-power laser systems
Post, R.F.; Vann, C.S.
1998-07-07
A mechanical beam isolator uses rod-shaped elements having a Gaussian configuration to interrupt the path of a beam of photons or particles when the time-scale of the needed interruption is of the order of a microsecond or less. One or more of these rods is mounted transversely to, and penetrates through, a rotating shaft supported by bearings. Owing to the Gaussian geometry of the rods, they are able to withstand much higher rotation speeds, without tensile failure, than rods having any other geometrical shape. 3 figs.
Safeguards by Design Challenge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alwin, Jennifer Louise
The International Atomic Energy Agency (IAEA) defines Safeguards as a system of inspection and verification of the peaceful uses of nuclear materials as part of the Nuclear Nonproliferation Treaty. IAEA oversees safeguards worldwide. Safeguards by Design (SBD) involves incorporation of safeguards technologies, techniques, and instrumentation during the design phase of a facility, rather that after the fact. Design challenge goals are the following: Design a system of safeguards technologies, techniques, and instrumentation for inspection and verification of the peaceful uses of nuclear materials. Cost should be minimized to work with the IAEA’s limited budget. Dose to workers should always bemore » as low are reasonably achievable (ALARA). Time is of the essence in operating facilities and flow of material should not be interrupted significantly. Proprietary process information in facilities may need to be protected, thus the amount of information obtained by inspectors should be the minimum required to achieve the measurement goal. Then three different design challenges are detailed: Plutonium Waste Item Measurement System, Marine-based Modular Reactor, and Floating Nuclear Power Plant (FNPP).« less
Cyber: A Flexible Deterrent Option
2013-02-14
to come on when they throw a switch and other electrical appliances throughout the house to work without any commercial power interruption. For...power plants this means maintaining the electrical grid and the supervisory control and data acquisition (SCADA) systems at a reliable rate of “99.99999...on the grid.”36 The researchers “simply instructed it to make rapid changes in the electricity cycles that powered the equipment: fast, slow, fast
Taube, M.; Porter, R. J.; Lord, P. H.
1983-01-01
We have conducted a controlled trial to compare skin closure using conventional interrupted sutures with a combination of subcuticular suture and sterile Micropore tape in 169 patients undergoing appendicectomy, inguinal herniorrhaphy, or saphenofemoral ligation. We have found that the combination technique consistently gives a better cosmetic result and that the tape acts well as a dressing, is convenient, and is well tolerated by patients. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6344732
Fast Interrupt Priority Management in Operating System Kernels
1993-05-01
We present results for the Mach 3.0 microkernel operating system, although the technique is applicable to other kernel architectures, both micro and...protection in the Mach 3.0 microkernel for several different processor architectures. For example, on the Omron Luna88k, we observed a 50% reduction in...general interrupt mask raise/lower pair within the Mach 3.0 microkernel on a variety of architectures. DTIC QUALM i.N1’R%.*1IMD 5 k81tltC Avail andl
Study of DC Circuit Breaker of H2-N2 Mixture Gas for High Voltage
NASA Astrophysics Data System (ADS)
Shiba, Yuji; Morishita, Yukinaga; Kaneko, Shuhei; Okabe, Shigemitsu; Mizoguchi, Hitoshi; Yanabu, Satoru
Global warming caused by CO2 etc. is a field where the concern is very high. Especially, automobile emissions are problem for it. Therefore, the hybrid car is widely development and used recently. Hybrid car used electric power and gasoline. So, the car reduces CO2. Hybrid car has engine and motor. To rotate the motor, hybrid car has battery. This battery is large capacity. Therefore, the relay should interrupt high DC current for the switch of the motor and the engine. So, hybrid car used hydrogen gas filling relay We studied interruption test for the research of a basic characteristic of hydrogen gas. DC current has not current zero point. So, it is necessary to make the current zero by high arc voltage and forcible current zero point. The loss coefficient and arc voltage of hydrogen is high. Therefore, we studied interruption test for used high arc voltage. We studied interruption test and dielectric breakdown test of air, pure Hydrogen, and Hydrogen- nitrogen mixture gas. As a result, we realized H2-N2(80%-20%) is the best gas.
Ji, Ya-Bin; Wu, Yong-Ming; Ji, Zhong; Song, Wei; Xu, Sui-Yi; Wang, Yao; Pan, Su-Yue
2012-07-01
Intracarotid artery cold saline infusion (ICSI) is an effective method for protecting brain tissue, but its use is limited because of undesirable secondary effects, such as severe decreases in hematocrit levels, as well as its relatively brief duration. In this study, the authors describe and investigate the effects of a novel ICSI pattern (interrupted ICSI) relative to the traditional method (uninterrupted ICSI). Ischemic strokes were induced in 85 male Sprague-Dawley rats by occluding the middle cerebral artery for 3 hours using an intraluminal filament. Uninterrupted infusion groups received an infusion at 15 ml/hour for 30 minutes continuously. The same infusion speed was used in the interrupted infusion groups, but the whole duration was divided into trisections, and there was a 20-minute interval without infusion between sections. Forty-eight hours after reperfusion, H & E and silver nitrate staining were utilized for morphological assessment. Infarct sizes and brain water contents were determined using H & E staining and the dry-wet weight method, respectively. Levels of neuron-specific enolase (NSE), S100β protein, and matrix metalloproteinase 9 (MMP-9) in the serum were determined using enzyme-linked immunosorbent assay. Neurological deficits were also evaluated. Histology showed that interrupted ICSI did not affect neurons or fibers in rat brains, which suggests that this method is safe for brain tissues with ischemia. The duration of hypothermia induced by interrupted ICSI was longer than that induced via the traditional method, and the decrease in hematocrit levels was less pronounced. There were no differences in infarct size or brain water content between uninterrupted and interrupted ICSI groups, but neuron-specific enolase and matrix metalloproteinase 9 serum levels were more reduced after interrupted ICSI than after the traditional method. Interrupted ICSI is a safe method. Compared with traditional ICSI, the interrupted method has a longer duration of hypothermia and less effect on hematocrit and offers more potentially improved neuroprotection, thereby making it more attractive as an infusion technique in the clinic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-01-09
GENI Project: General Atomics is developing a direct current (DC) circuit breaker that could protect the grid from faults 100 times faster than its alternating current (AC) counterparts. Circuit breakers are critical elements in any electrical system. At the grid level, their main function is to isolate parts of the grid where a fault has occurred—such as a downed power line or a transformer explosion—from the rest of the system. DC circuit breakers must interrupt the system during a fault much faster than AC circuit breakers to prevent possible damage to cables, converters and other grid-level components. General Atomics’ high-voltagemore » DC circuit breaker would react in less than 1/1,000th of a second to interrupt current during a fault, preventing potential hazards to people and equipment.« less
Metal vapor arc switch electromagnetic accelerator technology
NASA Technical Reports Server (NTRS)
Mongeau, P. P.
1984-01-01
A multielectrode device housed in an insulator vacuum vessel, the metal vapor vacuum switch has high power capability and can hold off voltages up to the 100 kilovolt level. Such switches can be electronically triggered and can interrupt or commutate at a zero current crossing. The physics of arc initiation, arc conduction, and interruption are examined, including material considerations; inefficiencies; arc modes; magnetic field effects; passive and forced extinction; and voltage recovery. Heating, electrode lifetime, device configuration, and external circuit configuration are discussed. The metal vapor vacuum switch is compared with SCRs, GTOs, spark gaps, ignitrons, and mechanical breakers.
NASA Astrophysics Data System (ADS)
Parsons, W. M.; Sims, J. R.; Parker, J. V.
1986-11-01
The Lethality Test System (LTS) under construction at Los Alamos is an electromagnetic launcher facility designed to perform impact experiments at velocities up to 15 km/sec. The launcher is a 25 mm round bore, plasma armature railgun 22 m in length. Preinjection is accomplished with a two-stage light gas gun capable of 7 km/sec. The railgun power supply utilizes traction motors, vacuum interrupters, and pulse transformers. An assembly of 28 traction motors, equipped with flywheels, stores approximately 80 MJ at 92 percent of full speed and energizes the primary windings of three pulse transformers at a current of 50 kA. At peak current an array of vacuum interrupters disconnects the transformer primary windings and forces the current to flow in the secondary windings. The secondary windings are connected to the railgun, and by staging the vacuum interrupter openings, a 1-1.3 MA ramped current waveform will be delivered to the railgun.
RESTOP: Retaining External Peripheral State in Intermittently-Powered Sensor Systems.
Rodriguez Arreola, Alberto; Balsamo, Domenico; Merrett, Geoff V; Weddell, Alex S
2018-01-10
Energy harvesting sensor systems typically incorporate energy buffers (e.g., rechargeable batteries and supercapacitors) to accommodate fluctuations in supply. However, the presence of these elements limits the miniaturization of devices. In recent years, researchers have proposed a new paradigm, transient computing, where systems operate directly from the energy harvesting source and allow computation to span across power cycles, without adding energy buffers. Various transient computing approaches have addressed the challenge of power intermittency by retaining the processor's state using non-volatile memory. However, no generic approach has yet been proposed to retain the state of peripherals external to the processing element. This paper proposes RESTOP, flexible middleware which retains the state of multiple external peripherals that are connected to a computing element (i.e., a microcontroller) through protocols such as SPI or I 2 C. RESTOP acts as an interface between the main application and the peripheral, which keeps a record, at run-time, of the transmitted data in order to restore peripheral configuration after a power interruption. RESTOP is practically implemented and validated using three digitally interfaced peripherals, successfully restoring their configuration after power interruptions, imposing a maximum time overhead of 15% when configuring a peripheral. However, this represents an overhead of only 0.82% during complete execution of our typical sensing application, which is substantially lower than existing approaches.
Rose, Adam; Oladosu, Gbadebo; Liao, Shu-Yi
2007-06-01
Regional economies are highly dependent on electricity, thus making their power supply systems attractive terrorist targets. We estimate the largest category of economic losses from electricity outages-business interruption-in the context of a total blackout of electricity in Los Angeles. We advance the state of the art in the estimation of the two factors that strongly influence the losses: indirect effects and resilience. The results indicate that indirect effects in the context of general equilibrium analysis are moderate in size. The stronger factor, and one that pushes in the opposite direction, is resilience. Our analysis indicates that electricity customers have the ability to mute the potential shock to their business operations by as much as 86%. Moreover, market resilience lowers the losses, in part through the dampening of general equilibrium effects.
Joe, Hyunwoo; Woo, Duk-Kyun; Kim, Hyungshin
2013-01-01
Sensor network simulations require high fidelity and timing accuracy to be used as an implementation and evaluation tool. The cycle-accurate and instruction-level simulator is the known solution for these purposes. However, this type of simulation incurs a high computation cost since it has to model not only the instruction level behavior but also the synchronization between multiple sensors for their causality. This paper presents a novel technique that exploits asynchronous simulations of interrupt service routines (ISR). We can avoid the synchronization overheads when the interrupt service routines are simulated without preemption. If the causality errors occur, we devise a rollback procedure to restore the original synchronized simulation. This concept can be extended to any instruction-level sensor network simulator. Evaluation results show our method can enhance the simulation speed up to 52% in the case of our experiments. For applications with longer interrupt service routines and smaller number of preemptions, the speedup becomes greater. In addition, our simulator is 2 to 11 times faster than the well-known sensor network simulator. PMID:23966200
Stochastic Optimization in The Power Management of Bottled Water Production Planning
NASA Astrophysics Data System (ADS)
Antoro, Budi; Nababan, Esther; Mawengkang, Herman
2018-01-01
This paper review a model developed to minimize production costs on bottled water production planning through stochastic optimization. As we know, that planning a management means to achieve the goal that have been applied, since each management level in the organization need a planning activities. The built models is a two-stage stochastic models that aims to minimize the cost on production of bottled water by observing that during the production process, neither interfernce nor vice versa occurs. The models were develop to minimaze production cost, assuming the availability of packing raw materials used considered to meet for each kind of bottles. The minimum cost for each kind production of bottled water are expressed in the expectation of each production with a scenario probability. The probability of uncertainly is a representation of the number of productions and the timing of power supply interruption. This is to ensure that the number of interruption that occur does not exceed the limit of the contract agreement that has been made by the company with power suppliers.
NASA Astrophysics Data System (ADS)
Marušáková, Daniela; Bublíková, Petra; Berka, Jan; Vávrovcová, Zuzana; Burda, Jaroslav
2017-09-01
To understand the degradation process of metal materials which are used in power engineering, appropriate evaluation procedure is necessary to ensure. In that order, the degradation of alloy 800H during the first period of test operation in High Temperature Helium Loop (HTHL) was tested. Experiment was carried out in atmosphere of pure technical helium with purity 4.6 containing only residual concentration of moisture up to 300 vppm. Parameters during the operation test were not constant, process was interrupted several times. The maximum temperature on specimens during this period was 750 °C, average temperature was 460 °C, gas pressure ranged from 3 to 6 MPa and gas flow from 3 to 9 gs-1. Total duration of the test was 264 h. After the exposure the degradation of specimens was investigated by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). Using the technique of Focused Ion Beam (FIB) integrated within SEM the transparent samples with quality surface parameters were obtained for TEM analysis. FIB technique in combination with High Resolution TEM ensured the guaranteed methodology of exposed sample preparation and precise description of changes in this kind of material.
System reliability and recovery.
DOT National Transportation Integrated Search
1971-06-01
The paper exhibits a variety of reliability techniques applicable to future ATC data processing systems. Presently envisioned schemes for error detection, error interrupt and error analysis are considered, along with methods of retry, reconfiguration...
Design of capacity incentive and energy compensation for demand response programs
NASA Astrophysics Data System (ADS)
Liu, Zhoubin; Cui, Wenqi; Shen, Ran; Hu, Yishuang; Wu, Hui; Ye, Chengjin
2018-02-01
Variability and Uncertainties caused by renewable energy sources have called for large amount of balancing services. Demand side resources (DSRs) can be a good alternative of traditional generating units to provide balancing service. In the areas where the electricity market has not been fully established, e.g., China, DSRs can help balance the power system with incentive-based demand response programs. However, there is a lack of information about the interruption cost of consumers in these areas, making it hard to determine the rational amount of capacity incentive and energy compensation for the participants of demand response programs. This paper proposes an algorithm to calculate the amount of capacity incentive and energy compensation for demand response programs when there lacks the information about interruption cost. Available statistical information of interruption cost in referenced areas is selected as the referenced data. Interruption cost of the targeted area is converted from the referenced area by product per electricity consumption. On this basis, capacity incentive and energy compensation are obtained to minimize the payment to consumers. Moreover, the loss of consumers is guaranteed to be covered by the revenue they earned from load serving entities.
Arc lamp power supply using a voltage multiplier
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.
1988-01-01
A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.
Study on Insulation Diagnosis of Power Lines in Apartment Houses
NASA Astrophysics Data System (ADS)
Okamoto, Tatsuki; Taki, Shoji; Fukui, Toshiaki; Soga, Akiya; Ezure, Shoichiro; Asano, Jun-Ichi; Uto, Yukio
Insulation diagnosis is vital issue for safety of urban lives despite of the difficulty of power interruption even for the diagnosis. Recently, live-line insulation diagnosis becomes more important and realistic to maintain good insulation conditions of power lines in apartment houses in wide range of residential sizes. This paper describes new trend of insulation diagnosis of power lines of apartment houses based on clip-on current measurement method with a lot of live-line measurement data and also describes the applicability of new live-line insulation diagnostic method.
Code of Federal Regulations, 2010 CFR
2010-04-01
... nature of clinical care services by visiting nurses, and transportation furnished for medical care. (d... contingency that interrupts or impairs a member's earning power. (e) Examples of other benefits. Paying...
Code of Federal Regulations, 2011 CFR
2011-04-01
... nature of clinical care services by visiting nurses, and transportation furnished for medical care. (d... contingency that interrupts or impairs a member's earning power. (e) Examples of other benefits. Paying...
Code of Federal Regulations, 2012 CFR
2012-04-01
... nature of clinical care services by visiting nurses, and transportation furnished for medical care. (d... contingency that interrupts or impairs a member's earning power. (e) Examples of other benefits. Paying...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-20
... replacement of the power control relays in the P91 and P92 power distribution panels for the fuel boost and override pumps with new, improved relays having a ground fault interrupter (GFI) feature, or installation... specify which relays may be replaced by GFIs or UFIs. We are proposing this AD to prevent pump housing...
Telemetry Standards, RCC Standard 106-17, Chapter 27, RF Network Access Layer
2017-07-01
27-13 27.5.5 Frame Check Sequence Field........................................................................... 27-13 27.6 Power Transients...to the physical media (i.e., the wireless RF network). On the transmission side, it is responsible for framing IP packets for physical transmission...parameters of a radio shall be stored to maintain communications with RF link management after a power interruption or software-initiated reset
Committee Opinion No. 723 Summary: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.
2017-10-01
Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.
Committee Opinion No. 723: Guidelines for Diagnostic Imaging During Pregnancy and Lactation.
2017-10-01
Imaging studies are important adjuncts in the diagnostic evaluation of acute and chronic conditions. However, confusion about the safety of these modalities for pregnant and lactating women and their infants often results in unnecessary avoidance of useful diagnostic tests or the unnecessary interruption of breastfeeding. Ultrasonography and magnetic resonance imaging are not associated with risk and are the imaging techniques of choice for the pregnant patient, but they should be used prudently and only when use is expected to answer a relevant clinical question or otherwise provide medical benefit to the patient. With few exceptions, radiation exposure through radiography, computed tomography scan, or nuclear medicine imaging techniques is at a dose much lower than the exposure associated with fetal harm. If these techniques are necessary in addition to ultrasonography or magnetic resonance imaging or are more readily available for the diagnosis in question, they should not be withheld from a pregnant patient. Breastfeeding should not be interrupted after gadolinium administration.
NASA Astrophysics Data System (ADS)
Yokomizu, Yasunobu
Dispersed generation systems, such as micro gas-turbines and fuel cells, have been installed on some of commercial facilities. Smaller dispersed generators like solar photovoltaics have been also located on the several of individual homes. The trends in the introduction of the these generation systems seem to continue in the future and to cause the power system to have the enormous number of the dispersed generation systems. The present report discusses the near-future power distribution systems.
NASA Astrophysics Data System (ADS)
Ohba, Masamichi; Nohara, Daisuke; Kadokura, Shinji
2016-04-01
Severe storms or other extreme weather events can interrupt the spin of wind turbines in large scale that cause unexpected "wind ramp events". In this study, we present an application of self-organizing maps (SOMs) for climatological attribution of the wind ramp events and their probabilistic prediction. The SOM is an automatic data-mining clustering technique, which allows us to summarize a high-dimensional data space in terms of a set of reference vectors. The SOM is applied to analyze and connect the relationship between atmospheric patterns over Japan and wind power generation. SOM is employed on sea level pressure derived from the JRA55 reanalysis over the target area (Tohoku region in Japan), whereby a two-dimensional lattice of weather patterns (WPs) classified during the 1977-2013 period is obtained. To compare with the atmospheric data, the long-term wind power generation is reconstructed by using a high-resolution surface observation network AMeDAS (Automated Meteorological Data Acquisition System) in Japan. Our analysis extracts seven typical WPs, which are linked to frequent occurrences of wind ramp events. Probabilistic forecasts to wind power generation and ramps are conducted by using the obtained SOM. The probability are derived from the multiple SOM lattices based on the matching of output from TIGGE multi-model global forecast to the WPs on the lattices. Since this method effectively takes care of the empirical uncertainties from the historical data, wind power generation and ramp is probabilistically forecasted from the forecasts of global models. The predictability skill of the forecasts for the wind power generation and ramp events show the relatively good skill score under the downscaling technique. It is expected that the results of this study provides better guidance to the user community and contribute to future development of system operation model for the transmission grid operator.
40 CFR 53.54 - Test for proper sampler operation following power interruptions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... test, the absolute difference in values calculated in Equation 10 of this paragraph (f)(4) must not...
40 CFR 53.54 - Test for proper sampler operation following power interruptions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... test, the absolute difference in values calculated in Equation 10 of this paragraph (f)(4) must not...
40 CFR 53.54 - Test for proper sampler operation following power interruptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... test, the absolute difference in values calculated in Equation 10 of this paragraph (f)(4) must not...
40 CFR 53.54 - Test for proper sampler operation following power interruptions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... test, the absolute difference in values calculated in Equation 10 of this paragraph (f)(4) must not...
40 CFR 53.54 - Test for proper sampler operation following power interruptions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... test, the absolute difference in values calculated in Equation 10 of this paragraph (f)(4) must not...
Electric service reliability cost/worth assessment in a developing country
NASA Astrophysics Data System (ADS)
Pandey, Mohan Kumar
Considerable work has been done in developed countries to optimize the reliability of electric power systems on the basis of reliability cost versus reliability worth. This has yet to be considered in most developing countries, where development plans are still based on traditional deterministic measures. The difficulty with these criteria is that they cannot be used to evaluate the economic impacts of changing reliability levels on the utility and the customers, and therefore cannot lead to an optimum expansion plan for the system. The critical issue today faced by most developing countries is that the demand for electric power is high and growth in supply is constrained by technical, environmental, and most importantly by financial impediments. Many power projects are being canceled or postponed due to a lack of resources. The investment burden associated with the electric power sector has already led some developing countries into serious debt problems. This thesis focuses on power sector issues facing by developing countries and illustrates how a basic reliability cost/worth approach can be used in a developing country to determine appropriate planning criteria and justify future power projects by application to the Nepal Integrated Electric Power System (NPS). A reliability cost/worth based system evaluation framework is proposed in this thesis. Customer surveys conducted throughout Nepal using in-person interviews with approximately 2000 sample customers are presented. The survey results indicate that the interruption cost is dependent on both customer and interruption characteristics, and it varies from one location or region to another. Assessments at both the generation and composite system levels have been performed using the customer cost data and the developed NPS reliability database. The results clearly indicate the implications of service reliability to the electricity consumers of Nepal, and show that the reliability cost/worth evaluation is both possible and practical in a developing country. The average customer interruption costs of Rs 35/kWh at Hierarchical Level I and Rs 26/kWh at Hierarchical Level II evaluated in this research work led to an optimum reserve margin of 7.5%, which is considerably lower than the traditional reserve margin of 15% used in the NPS. A similar conclusion may result in other developing countries facing difficulties in power system expansion planning using the traditional approach. A new framework for system planning is therefore recommended for developing countries which would permit an objective review of the traditional system planning approach, and the evaluation of future power projects using a new approach based on fundamental principles of power system reliability and economics.
PROTOTYPIC CONTINUITY METHODS FOR FASTER RECOVERY OF OIL PRODUCTS SUPPLY AFTER GREAT QUAKE
NASA Astrophysics Data System (ADS)
Yasuno, Takato
In the Great East Japan Earthquake, some oil product farms and tanks had a lot of damages. Then we temporally run short of oil products such as gasoline, lamp oil. The oil product is indispensable to make cargo shipment, or rescue operations, and some trouble must come for everyday shopping and movement of business. The lifeline damages come out electric power, water service, gas and communication. In addition the oil product shortage overlaps then the importance to restore was recognized. After earthquake disaster, there is a possibility to interrupt supply services such as shipping from oil tanks and sale at stations. Even if their discontinuation comes, it needs some business continuity policies in order to recover supply service at early stage. This paper grasps oil product discontinuation of supply and restoration transition and tries to get disaster lessons. This paper proposes prototypic techniques to minimize the sum of penalties to supply no service for neighbor region with capacities of critical stations. It applies to Tohoku regions and their gas stations and comments the usefulness of techniques and implication of supply service continuity policy.
RESTOP: Retaining External Peripheral State in Intermittently-Powered Sensor Systems
Rodriguez Arreola, Alberto; Balsamo, Domenico
2018-01-01
Energy harvesting sensor systems typically incorporate energy buffers (e.g., rechargeable batteries and supercapacitors) to accommodate fluctuations in supply. However, the presence of these elements limits the miniaturization of devices. In recent years, researchers have proposed a new paradigm, transient computing, where systems operate directly from the energy harvesting source and allow computation to span across power cycles, without adding energy buffers. Various transient computing approaches have addressed the challenge of power intermittency by retaining the processor’s state using non-volatile memory. However, no generic approach has yet been proposed to retain the state of peripherals external to the processing element. This paper proposes RESTOP, flexible middleware which retains the state of multiple external peripherals that are connected to a computing element (i.e., a microcontroller) through protocols such as SPI or I2C. RESTOP acts as an interface between the main application and the peripheral, which keeps a record, at run-time, of the transmitted data in order to restore peripheral configuration after a power interruption. RESTOP is practically implemented and validated using three digitally interfaced peripherals, successfully restoring their configuration after power interruptions, imposing a maximum time overhead of 15% when configuring a peripheral. However, this represents an overhead of only 0.82% during complete execution of our typical sensing application, which is substantially lower than existing approaches. PMID:29320441
Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred
2011-03-01
Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.
10 CFR 205.352 - Information to be reported.
Code of Federal Regulations, 2010 CFR
2010-01-01
... DEPARTMENT OF ENERGY OIL ADMINISTRATIVE PROCEDURES AND SANCTIONS Electric Power System Permits and Reports; Applications; Administrative Procedures and Sanctions Report of Major Electric Utility System Emergencies § 205... stations or air traffic control systems, were or are interrupted. To the extent known or reasonably...
White, David B.
1991-01-01
An electrical safety device for use in power tools that is designed to automatically discontinue operation of the power tool upon physical contact of the tool with a concealed conductive material. A step down transformer is used to supply the operating power for a disconnect relay and a reset relay. When physical contact is made between the power tool and the conductive material, an electrical circuit through the disconnect relay is completed and the operation of the power tool is automatically interrupted. Once the contact between the tool and conductive material is broken, the power tool can be quickly and easily reactivated by a reset push button activating the reset relay. A remote reset is provided for convenience and efficiency of operation.
Tritium-powered radiation sensor network
NASA Astrophysics Data System (ADS)
Litz, Marc S.; Russo, Johnny A.; Katsis, Dimos
2016-05-01
Isotope power supplies offer long-lived (100 years using 63Ni), low-power energy sources, enabling sensors or communications nodes for the lifetime of infrastructure. A tritium beta-source (12.5-year half-life) encapsulated in a phosphor-lined vial couples directly to a photovoltaic (PV) to generate a trickle current into an electrical load. An inexpensive design is described using commercial-of-the-shelf (COTS) components that generate 100 μWe for nextgeneration compact electronics/sensors. A matched radiation sensor has been built for long-duration missions utilizing microprocessor-controlled sleep modes, low-power electronic components, and a passive interrupt driven environmental wake-up. The low-power early-warning radiation detector network and isotope power source enables no-maintenance mission lifetimes.
Viscoelastic behavior of lung and chest wall in dogs determined by flow interruption.
Similowski, T; Levy, P; Corbeil, C; Albala, M; Pariente, R; Derenne, J P; Bates, J H; Jonson, B; Milic-Emili, J
1989-12-01
Pulmonary and chest wall mechanics were studied in six anesthetized paralyzed dogs, by use of the technique of rapid airway occlusion during constant flow inflation. Analysis of the pressure changes after flow interruption allowed us to partition the overall resistance of the lung (Rl) and chest wall (Rw) and total respiratory system (Rrs) into two components, one (Rinit) reflecting in the lung airway resistance (Raw), the other (delta R) reflecting primarily the viscoelastic properties of the pulmonary and chest wall tissues. The effects of varying inspiratory flow and inflation volume were interpreted in terms of frequency dependence of resistance, by using a spring-and-dashpot model previously proposed and substantiated by Bates et al. (Proc. 9th Annu. Conf. IEEE Med. Biol. Soc., 1987, vol. 3, p. 1802-1803). We observed that 1) Raw and Rw,init were nearly equal and small relative to Rl and Rw (both were unaffected by flow); 2) Rrs,init decreased slightly with increasing volume; 3) both delta Rl and delta Rw decreased with increasing flow and increased with increasing lung volume. These changes were manifestations of frequency dependence of delta R, as it is predicted by the model; 4) Rrs, Rl, and Rw followed the same trends as delta R. These results corroborate data previously reported in the literature with the use of different techniques to measure airways and pulmonary tissue resistances and confirm that the use of Rl to assess bronchial reactivity is problematic. The interrupter techniques provides a convenient way to obtain Raw values, as well as analogs of lung and chest wall tissue resistances in intact dogs.
18 CFR 284.284 - Blanket certificates for unbundled sales services.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for unbundled sales services under paragraph (a) of this section, interruptible sales volumes under... for unbundled sales services. 284.284 Section 284.284 Conservation of Power and Water Resources... ACT OF 1978 AND RELATED AUTHORITIES CERTAIN SALES AND TRANSPORTATION OF NATURAL GAS UNDER THE NATURAL...
30 CFR 57.22301 - Atmospheric monitoring systems (I-A, II-A, and V-A mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... when methane at any sensor reaches 0.5 percent or more, and when power to a sensor is interrupted... determined by MSHA to be intrinsically safe under 30 CFR part 18, when methane at any sensor reaches— (i) 1.0...
30 CFR 57.22301 - Atmospheric monitoring systems (I-A, II-A, and V-A mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... when methane at any sensor reaches 0.5 percent or more, and when power to a sensor is interrupted... determined by MSHA to be intrinsically safe under 30 CFR part 18, when methane at any sensor reaches— (i) 1.0...
30 CFR 57.22301 - Atmospheric monitoring systems (I-A, II-A, and V-A mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... when methane at any sensor reaches 0.5 percent or more, and when power to a sensor is interrupted... determined by MSHA to be intrinsically safe under 30 CFR part 18, when methane at any sensor reaches— (i) 1.0...
30 CFR 57.22301 - Atmospheric monitoring systems (I-A, II-A, and V-A mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... when methane at any sensor reaches 0.5 percent or more, and when power to a sensor is interrupted... determined by MSHA to be intrinsically safe under 30 CFR part 18, when methane at any sensor reaches— (i) 1.0...
30 CFR 57.22301 - Atmospheric monitoring systems (I-A, II-A, and V-A mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... when methane at any sensor reaches 0.5 percent or more, and when power to a sensor is interrupted... determined by MSHA to be intrinsically safe under 30 CFR part 18, when methane at any sensor reaches— (i) 1.0...
77 FR 60331 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... (NLG) retraction. This proposed AD would require installing a power interruption protection circuit for... unlocking and/or retraction of the NLG, which, while on the ground, could result in injury to ground... A320 aeroplane was preparing to initiate taxi, when an uncommanded nose landing gear (NLG) retraction...
Texts, Troubled Teens, and Troubling Times
ERIC Educational Resources Information Center
Tatum, Alfred W., Ed.
2009-01-01
Seeking ways to effectively mediate texts with troubled teens in troubling times is worth the investment. Text is a powerful tool for shaping positive life trajectories, especially for those teens being affected by vulnerable-producing conditions that interrupt positive human development. These conditions, coupled with poor literacy skills…
Isotope-ratio-monitoring gas chromatography-mass spectrometry: methods for isotopic calibration
NASA Technical Reports Server (NTRS)
Merritt, D. A.; Brand, W. A.; Hayes, J. M.
1994-01-01
In trial analyses of a series of n-alkanes, precise determinations of 13C contents were based on isotopic standards introduced by five different techniques and results were compared. Specifically, organic-compound standards were coinjected with the analytes and carried through chromatography and combustion with them; or CO2 was supplied from a conventional inlet and mixed with the analyte in the ion source, or CO2 was supplied from an auxiliary mixing volume and transmitted to the source without interruption of the analyte stream. Additionally, two techniques were investigated in which the analyte stream was diverted and CO2 standards were placed on a near-zero background. All methods provided accurate results. Where applicable, methods not involving interruption of the analyte stream provided the highest performance (sigma = 0.00006 at.% 13C or 0.06% for 250 pmol C as CO2 reaching the ion source), but great care was required. Techniques involving diversion of the analyte stream were immune to interference from coeluting sample components and still provided high precision (0.0001 < or = sigma < or = 0.0002 at.% or 0.1 < or = sigma < or = 0.2%).
Brain activity patterns induced by interrupting the cognitive processes with online advertising.
Rejer, Izabela; Jankowski, Jarosław
2017-11-01
As a result of the increasing role of online advertising and strong competition among advertisers, intrusive techniques are commonly used to attract web users' attention. Moreover, since marketing content is usually delivered to the target audience when they are performing typical online tasks, like searching for information or reading online content, its delivery interrupts the web user's current cognitive process. The question posed by many researchers in the field of online advertising is: how should we measure the influence of interruption of cognitive processes on human behavior and emotional state? Much research has been conducted in this field; however, most of this research has focused on monitoring activity in the simulated environment, or processing declarative responses given by users in prepared questionnaires. In this paper, a more direct real-time approach is taken, and the effect of the interruption on a web user is analyzed directly by studying the activity of his brain. This paper presents the results of an experiment that was conducted to find the brain activity patterns associated with interruptions of the cognitive process by showing internet advertisements during a text-reading task. Three specific aspects were addressed in the experiment: individual patterns, the consistency of these patterns across trials, and the intra-subject correlation of the individual patterns. Two main effects were observed for most subjects: a drop in activity in the frontal and prefrontal cortical areas across all frequency bands, and significant changes in the frontal/prefrontal asymmetry index.
Jablonski, Ireneusz; Mroczka, Janusz
2010-01-01
The paper offers an enhancement of the classical interrupter technique algorithm dedicated to respiratory mechanics measurements. Idea consists in exploitation of information contained in postocclusional transient states during indirect measurement of parameter characteristics by model identification. It needs the adequacy of an inverse analogue to general behavior of the real system and a reliable algorithm of parameter estimation. The second one was a subject of reported works, which finally showed the potential of the approach to separation of airway and tissue response in a case of short-term excitation by interrupter valve operation. Investigations were conducted in a regime of forward-inverse computer experiment.
NASA Astrophysics Data System (ADS)
Naito, Yuji; Shimizu, Iwao; Yamaguchi, Iwao; Kaiho, Katsuyuki; Yanabu, Satoru
Using high temperature superconductor, a Superconducting Fault Current Limiter (SFCL) was made and tested. Superconductor and vacuum interrupter as commutation switch are connected in parallel with bypass coil. When a fault occurs and the excessive current flows, superconductor is first quenched and the current is transferred to bypass coil because on voltage drop of superconductor. At the same time, since magnetic field is generated by current which flows in bypass coil, commutation switch is immediately driven by electromagnetic repulsion plate connected to driving rod of vacuum interrupter, and superconductor is separated from this circuit. Using the testing model, we could separate the superconductor from a circuit due to movement of vacuum interrupter within half-cycle current and transfer all current to bypass coil. Since operation of a commutation switch is included in current limiting operation of this testing model, it is one of helpful circuit of development of SFCL in the future. Moreover, since it can make the consumed energy of superconductor small during fault state due to realization of high-speed switch with simple composition, the burden of superconductor is reduced compared with conventional resistive type SFCL and it is considered that the flexibility of a SFCL design increases. Cooperation with a circuit breaker was also considered, the trial calculation of a parameter and energy of operation is conducted and discussion in the case of installing the SFCL to electric power system is made.
NASA Astrophysics Data System (ADS)
Chang, Kai-Sheng; Chen, Kuan-Ta; Hsu, Chun-Yao; Hong, Po-Da
2018-05-01
This paper determines the optimal settings in the deposition parameters for (AlCrNbSiTiV)N high-entropy alloy (HEAs) nitride films that are deposited on CBN cutting tools and glass substrates. We use direct current magnetron sputtering (DCMS) and high power impulse magnetron sputtering (HIPIMS), with Ar plasma and N2 reactive gases. Experiments with the grey-Taguchi method are conducted to determine the effect of deposition parameters (deposition time, substrate DC bias, DC power and substrate temperature) on interrupted turning 50CrMo4 steel machining and the films' structural properties. Experimental result shows that the multiple performance characteristics for these (AlCrNbSiTiV)N HEAs film coatings can be improved using the grey-Taguchi method. As can be seen, the coated film is homogeneous, very compact and exhibits perfect adherence to the substrate. The distribution of elements is homogeneous through the depth of the (AlCrNbSiTiV)N film, as measured by an auger electron nanoscope. After interrupted turning with an (AlCrNbSiTiV)N film coated tool, we obtain much longer tool life than when using uncoated tools. The correlation of these results with microstructure analysis and tool life indicates that HIPIMS discharge induced a higher (AlCrNbSiTiV)N film density, a smoother surface structure and a higher hardness surface.
NASA Technical Reports Server (NTRS)
Veyo, S.E.
1997-01-01
This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.
Diversity, Inequality, and a Post-Structural Politics for Education
ERIC Educational Resources Information Center
Youdell, Deborah
2006-01-01
This paper considers the contribution to understanding educational inequalities offered by post-structural theories of power and the subject. The paper locates this consideration in the context of the ongoing endeavour in education studies to make sense of, and identify ways of interrupting, abiding educational exclusions and inequalities. The…
77 FR 20505 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-05
... Company Model 757 airplanes. This AD requires replacing the power control relays for the fuel boost pumps and override pumps with new relays having a ground fault interrupter (GFI) feature. This AD also requires an electrical bonding resistance measurement for certain GFI relays to verify that certain bonding...
High performance protection circuit for power electronics applications
NASA Astrophysics Data System (ADS)
Tudoran, Cristian D.; Dǎdârlat, Dorin N.; Toşa, Nicoleta; Mişan, Ioan
2015-12-01
In this paper we present a high performance protection circuit designed for the power electronics applications where the load currents can increase rapidly and exceed the maximum allowed values, like in the case of high frequency induction heating inverters or high frequency plasma generators. The protection circuit is based on a microcontroller and can be adapted for use on single-phase or three-phase power systems. Its versatility comes from the fact that the circuit can communicate with the protected system, having the role of a "sensor" or it can interrupt the power supply for protection, in this case functioning as an external, independent protection circuit.
The effect of load history on reinforced concrete bridge column behavior : [summary].
DOT National Transportation Integrated Search
2012-08-01
To satisfy the aims of performance based design, levels of damage which interrupt the serviceability of the : structure or require more invasive repair techniques must be related to engineering criteria. In this report, the : influence of displacemen...
The effect of load history on reinforced concrete bridge column behavior.
DOT National Transportation Integrated Search
2012-08-01
To satisfy the aims of performance based design, levels of damage which interrupt the serviceability of the : structure or require more invasive repair techniques must be related to engineering criteria. In this report, the : influence of displacemen...
NASA Astrophysics Data System (ADS)
Snow, Marcellus S.
1989-09-01
A mathematical model is presented of costs and operational factors involved in provision for service interruptions of both a mature and typically large incumbent satellite system and of a smaller, more recently operational system. The equation expresses the required launch frequency for the new system as a function of the launch spacing of the mature system; the time disparity between the inauguration of the two systems; and the rate of capacity depreciation. In addition, a technique is presented to compare the relative extent to which the discounted costs of the new system exceed those of the mature system in furnishing the same effective capacity in orbit, and thus the same service liability, at a given point in time. It is determined that a mature incumbent communications satellite system, having more capacity in orbit, will on balance have a lower probability of service interruption than a newer, smaller system.
A study on reliability of power customer in distribution network
NASA Astrophysics Data System (ADS)
Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin
2017-05-01
The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.
Neonatal repair of right interrupted aortic arch with cerebro-myocardial perfusion technique.
Takeuchi, Koh; Masuzawa, Akihiro; Kobayashi, Jotaro; Tsuchiya, Keiji
2011-10-01
Right interrupted aortic arch and descending aorta is exceedingly rare and most likely cause respiratory presentation, since patent ductus arteriosus (PDA) courses over the right mainstem bronchus. We report a case of successful neonatal biventricular repair of a right interrupted aortic arch (type B), with an aberrant right subclavian artery ventricular septal defect (VSD) in a 2.7 kg term neonate with DiGeorge syndrome. Patient presented in severe respiratory distress and acidosis at one day old. Two-dimensional (2D) echocardiography revealed aortic arch interruption beyond the common carotid arteries with large perimembranous outlet VSD. Aortic annulus diameter was 4.8 mm and there was no left ventricle (LV) outflow tract obstruction. Three-dimensional (3D) CT-scan confirmed these findings and identified a right-sided ductal arch that continued over the right mainstem bronchus into a right-sided descending aorta and aberrant right subclavian artery. Brachiocephalic perfusion and ductal perfusion was employed for cooling during cardiopulmonary bypass. Under deep hypothermia (27 °C rectal temperature), selective cerebro-myocardial perfusion was used for successful aortic arch repair without sacrificing the aberrant right subclavian artery. A direct tension-free anastomosis was attained. Her postoperative course was uneventful and her respiratory symptoms disappeared postoperatively. Early surgical correction is mandatory for these patients with unique anatomy and presentation.
Detection of apnea using a short-window FFT technique and an artificial neural network
NASA Astrophysics Data System (ADS)
Waldemark, Karina E.; Agehed, Kenneth I.; Lindblad, Thomas; Waldemark, Joakim T. A.
1998-03-01
Sleep apnea is characterized by frequent prolonged interruptions of breathing during sleep. This syndrome causes severe sleep disorders and is often responsible for development of other diseases such as heart problems, high blood pressure and daytime fatigue, etc. After diagnosis, sleep apnea is often successfully treated by applying positive air pressure (CPAP) to the mouth and nose. Although effective, the (CPAP) equipment takes up a lot of space and the connected mask causes a lot of inconvenience for the patients. This raised interest in developing new techniques for treatment of sleep apnea syndrome. Several studies have indicated that electrical stimulation of the hypoglossal nerve and muscle in the tongue may be a useful method for treating patients with severe sleep apnea. In order to be able to successfully prevent the occurrence of apnea it is necessary to have some technique for early and fast on-line detection or prediction of the apnea events. This paper suggests using measurements of respiratory airflow (mouth temperature). The signal processing for this task includes the use of a short window FFT technique and uses an artificial back propagation neural net to model or predict the occurrence of apneas. The results show that early detection of respiratory interruption is possible and that the delay time for this is small.
Development of a 600 kJ HTS SMES
NASA Astrophysics Data System (ADS)
Seong, K. C.; Kim, H. J.; Kim, S. H.; Sim, K. D.; Sohn, M. H.; Lee, E. Y.; Park, S. J.; Hahn, S. Y.; Park, M. W.
2008-09-01
This paper describes an overview of development on a 600 kJ high-temperature superconducting magnetic energy storage (HTS SMES). Our final goal will be the commercialization of MJ class HTS SMES system for the increase of power quality within 5 years. Hence, for this purpose, we have developed the research and development in 3 years. The purpose of this research is to develop a pilot system, which can protect the sensitivity loads from a momentary power interruption or a voltage sag.
Electrical safety for high voltage arrays
NASA Technical Reports Server (NTRS)
Marshall, N. A.
1983-01-01
A number of key electrical safety requirements for the high voltage arrays of central station photovoltaic power systems are explored. The suitability of representative industrial DC power switchgear for control and fault protection was evaluated. Included were AC/DC circuit breakers, electromechanical contactors and relays, load interruptors, cold disconnect devices, sectionalizing switches, and high voltage DC fuses. As appropriate, steady state and transient characteristics were analyzed. Failure modes impacting upon operation and maintenance safety were also identified, as were the voltage withstand and current interruption levels.
A robust interrupted time series model for analyzing complex health care intervention data.
Cruz, Maricela; Bender, Miriam; Ombao, Hernando
2017-12-20
Current health policy calls for greater use of evidence-based care delivery services to improve patient quality and safety outcomes. Care delivery is complex, with interacting and interdependent components that challenge traditional statistical analytic techniques, in particular, when modeling a time series of outcomes data that might be "interrupted" by a change in a particular method of health care delivery. Interrupted time series (ITS) is a robust quasi-experimental design with the ability to infer the effectiveness of an intervention that accounts for data dependency. Current standardized methods for analyzing ITS data do not model changes in variation and correlation following the intervention. This is a key limitation since it is plausible for data variability and dependency to change because of the intervention. Moreover, present methodology either assumes a prespecified interruption time point with an instantaneous effect or removes data for which the effect of intervention is not fully realized. In this paper, we describe and develop a novel robust interrupted time series (robust-ITS) model that overcomes these omissions and limitations. The robust-ITS model formally performs inference on (1) identifying the change point; (2) differences in preintervention and postintervention correlation; (3) differences in the outcome variance preintervention and postintervention; and (4) differences in the mean preintervention and postintervention. We illustrate the proposed method by analyzing patient satisfaction data from a hospital that implemented and evaluated a new nursing care delivery model as the intervention of interest. The robust-ITS model is implemented in an R Shiny toolbox, which is freely available to the community. Copyright © 2017 John Wiley & Sons, Ltd.
CONTROL AND FAULT DETECTOR CIRCUIT
Winningstad, C.N.
1958-04-01
A power control and fault detectcr circuit for a radiofrequency system is described. The operation of the circuit controls the power output of a radio- frequency power supply to automatically start the flow of energizing power to the radio-frequency power supply and to gradually increase the power to a predetermined level which is below the point where destruction occurs upon the happening of a fault. If the radio-frequency power supply output fails to increase during such period, the control does not further increase the power. On the other hand, if the output of the radio-frequency power supply properly increases, then the control continues to increase the power to a maximum value. After the maximumn value of radio-frequency output has been achieved. the control is responsive to a ''fault,'' such as a short circuit in the radio-frequency system being driven, so that the flow of power is interrupted for an interval before the cycle is repeated.
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-01-01
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-07-21
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.
From Margins to Mainstream: Social Media as a Tool for Campus Sexual Violence Activism
ERIC Educational Resources Information Center
Linder, Chris; Myers, Jess S.; Riggle, Colleen; Lacy, Marvette
2016-01-01
Using Internet-related ethnography (Postill & Pink, 2012), we examined the role of social media in campus sexual violence activism. Based on observations of online activist communities and interviews with 23 activists, we highlight raising awareness, community building, and interrupting power dynamics as activism strategies enhanced by social…
Toy Modification Note. Revised.
ERIC Educational Resources Information Center
Vanderheiden, Gregg C.; And Others
Described are toy modifications which enable handicapped individuals to operate battery-powered toys. A battery interrupter is explained as a device which fits between the batteries in a toy and provides the ability to have a separate on-off switch which can be custom designed to fit a handicapped user's needs. Construction and use of three types…
Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo
2016-12-01
Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.
Servicing a globally broadcast interrupt signal in a multi-threaded computer
Attinella, John E.; Davis, Kristan D.; Musselman, Roy G.; Satterfield, David L.
2015-12-29
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whether global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.
Primary lithium cell life studies
NASA Technical Reports Server (NTRS)
Capulli, John; Donley, Sam; Deligiannis, Frank; Shen, David
1990-01-01
One solution for providing a truly independent power source is to package, within the critical subsystem element, a primary battery that can remain dormant for time periods as long as the mission life, which can be 10-15 years, maximum. When primary power from the spacecraft solar array/battery system is interrupted, the backup battery system, which is connected through a diode to the power input line, would automatically support the load to avoid a power interruption to the critical load for a time period long enough to ensure that ground control could access the satellite and correct the anomaly by sending appropriate commands to the spacecraft. Critical subsystems identified for the application are telemetry and command circuits, volatile computer memory, attitude control circuits, and some critical payloads. Due to volume packaging and weight restrictions that exist on most spacecraft, coupled with the long storage periods required, lithium cell technology was selected for the backup power source. Because of the high energy density (200-400 Wh/kg), long shelf life, and load capability, soluble cathode primary lithium technology was chosen. The most important lithium cell properties that require detail characterization for this application are capacity loss, shelf life, and the voltage delay mechanism. These are functions of storage time and temperature. During storage, a passive film builds up on the lithium electrode. The film protects the lithium electrode from progressive capacity decay but requires time to break down when a load is applied. This phenomenon results in a depressed voltage during the period of film breakdown which can last from fractions of a second to minutes.
High performance protection circuit for power electronics applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tudoran, Cristian D., E-mail: cristian.tudoran@itim-cj.ro; Dădârlat, Dorin N.; Toşa, Nicoleta
2015-12-23
In this paper we present a high performance protection circuit designed for the power electronics applications where the load currents can increase rapidly and exceed the maximum allowed values, like in the case of high frequency induction heating inverters or high frequency plasma generators. The protection circuit is based on a microcontroller and can be adapted for use on single-phase or three-phase power systems. Its versatility comes from the fact that the circuit can communicate with the protected system, having the role of a “sensor” or it can interrupt the power supply for protection, in this case functioning as anmore » external, independent protection circuit.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attinella, John E.; Davis, Kristan D.; Musselman, Roy G.
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whethermore » global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.« less
Data analysis techniques used at the Oak Ridge Y-12 plant flywheel evaluation laboratory
NASA Astrophysics Data System (ADS)
Steels, R. S., Jr.; Babelay, E. F., Jr.
1980-07-01
Some of the more advanced data analysis techniques applied to the problem of experimentally evaluating the performance of high performance composite flywheels are presented. Real time applications include polar plots of runout with interruptions relating to balance and relative motions between parts, radial growth measurements, and temperature of the spinning part. The technique used to measure torque applied to a containment housing during flywheel failure is also presented. The discussion of pre and post test analysis techniques includes resonant frequency determination with modal analysis, waterfall charts, and runout signals at failure.
Executing application function calls in response to an interrupt
Almasi, Gheorghe; Archer, Charles J.; Giampapa, Mark E.; Gooding, Thomas M.; Heidelberger, Philip; Parker, Jeffrey J.
2010-05-11
Executing application function calls in response to an interrupt including creating a thread; receiving an interrupt having an interrupt type; determining whether a value of a semaphore represents that interrupts are disabled; if the value of the semaphore represents that interrupts are not disabled: calling, by the thread, one or more preconfigured functions in dependence upon the interrupt type of the interrupt; yielding the thread; and if the value of the semaphore represents that interrupts are disabled: setting the value of the semaphore to represent to a kernel that interrupts are hard-disabled; and hard-disabling interrupts at the kernel.
NASA Technical Reports Server (NTRS)
Dwinell, W. S.
1979-01-01
In technique, voice circuits connecting crew's cabin to launch station through umbilical connector disconnect automatically unused, or deadened portion of circuits immediately after vehicle is launched, eliminating possibility that unused wiring interferes with voice communications inside vehicle or need for manual cutoff switch and its associated wiring. Technique is applied to other types of electrical actuation circuits, also launch of mapped vehicles, such as balloons, submarines, test sleds, and test chambers-all requiring assistance of ground crew.
A New QKD Protocol Based upon Authentication by EPR Entanglement State
NASA Astrophysics Data System (ADS)
Abushgra, Abdulbast A.
Cryptographic world has faced multiple challenges that are included in encoding and decoding transmitting information into a secure communication channel. Quantum cryptography may be another generation of the cryptography world, which is based on the law of physics. After decades of using the classical cryptography, there is an essential need to move a step forward through the most trusted systems, especially enormous amount of data flows through billions of communicating channels (e.g. The internet), and keeping this transmitting information away from eavesdropping is obligatory. Moreover, quantum cryptography has proved its standing against many weaknesses in the classical cryptography. One of these weaknesses is the ability to copy any type of information using a passive attack without an interruption, which is impossible in the quantum system. Theoretically, several quantum observables are utilized to diagnose an action of one particle. These observables are included in measuring mass, movement, speed, etc. The polarization of one photon occurs normally and randomly in the space. Any interruption that happens during sending of a light will cause a deconstruction of the light polarization. Therefore, particles' movement in a three-dimensional space is supported by Non-Cloning theory that makes eavesdroppers unable to interrupt a communication system. In case an eavesdropper tried to interrupt a photon, the photon will be destroyed after passing the photon into a quantum detector or any measurement device. In the last decades, many Quantum Key Distribution (QKD) protocols have been created to initiate a secret key during encoding and decoding transmitted data operations. Some of these protocols were proven un-secure based on the quantum attacks that were released early. Even though the power of physics is still active and the Non-Cloning theory is unbroken, some QKD protocols failed during the security measurements. The main reason of the failure is based on the inability to provide the authentication between the end users during the quantum and classical channels. The proposed QKD protocol was designed to utilize some advantages of quantum physics as well as solid functions that are used in the classical cryptography. The authentication is a requirement during different communication channels, where both legitimate parties must confirm their identities before starting to submit data (plain-text). Moreover, the protocol uses most needed scenarios to finish the communication without leaking important data. These scenarios have been approved in existing QKD protocols either by classical or quantum systems. The matrix techniques also are used as a part of the preparation of the authentication key, where the end users communicate by an EPR (related to Einstein, Podolsky, and Rosen theory in 1935 ) channel. The EPR channel will be supported by an entanglement of particles. If the EPR communication succeeded, transferring the converted plain-text is required. Finally, both end users will have an authenticated secret key, and the submission will be done without any interruption.
2014-01-01
Background Medication non-adherence is prevalent. We assessed the effect of electronic prescribing (e-prescribing) with formulary decision support on preferred formulary tier usage, copayment, and concomitant adherence. Methods We retrospectively analyzed 14,682 initial pharmaceutical claims for angiotensin receptor blocker and inhaled steroid medications among 14,410 patients of 2189 primary care physicians (PCPs) who were offered e-prescribing with formulary decision support, including 297 PCPs who adopted it. Formulary decision support was initially non-interruptive, such that formulary tier symbols were displayed adjacent to medication names. Subsequently, interruptive formulary decision support alerts also interrupted e-prescribing when preferred-tier alternatives were available. A difference in differences design was used to compare the pre-post differences in medication tier for each new prescription attributed to non-adopters, low user (<30% usage rate), and high user PCPs (>30% usage rate). Second, we modeled the effect of formulary tier on prescription copayment. Last, we modeled the effect of copayment on adherence (proportion of days covered) to each new medication. Results Compared with non-adopters, high users of e-prescribing were more likely to prescribe preferred-tier medications (vs. non-preferred tier) when both non-interruptive and interruptive formulary decision support were in place (OR 1.9 [95% CI 1.0-3.4], p = 0.04), but no more likely to prescribe preferred-tier when only non-interruptive formulary decision support was in place (p = 0.90). Preferred-tier claims had only slightly lower mean monthly copayments than non-preferred tier claims (angiotensin receptor blocker: $10.60 versus $11.81, inhaled steroid: $14.86 versus $16.42, p < 0.0001). Medication possession ratio was 8% lower for each $1.00 increase in monthly copayment to the one quarter power (p < 0.0001). However, we detected no significant direct association between formulary decision support usage and adherence. Conclusion Interruptive formulary decision support shifted prescribing toward preferred tiers, but these medications were only minimally less expensive in the studied patient population. In this context, formulary decision support did not significantly increase adherence. To impact cost-related non-adherence, formulary decision support will likely need to be paired with complementary drug benefit design. Formulary decision support should be studied further, with particular attention to its effect on adherence in the setting of different benefit designs. PMID:25167807
Pevnick, Joshua M; Li, Ning; Asch, Steven M; Jackevicius, Cynthia A; Bell, Douglas S
2014-08-28
Medication non-adherence is prevalent. We assessed the effect of electronic prescribing (e-prescribing) with formulary decision support on preferred formulary tier usage, copayment, and concomitant adherence. We retrospectively analyzed 14,682 initial pharmaceutical claims for angiotensin receptor blocker and inhaled steroid medications among 14,410 patients of 2189 primary care physicians (PCPs) who were offered e-prescribing with formulary decision support, including 297 PCPs who adopted it. Formulary decision support was initially non-interruptive, such that formulary tier symbols were displayed adjacent to medication names. Subsequently, interruptive formulary decision support alerts also interrupted e-prescribing when preferred-tier alternatives were available. A difference in differences design was used to compare the pre-post differences in medication tier for each new prescription attributed to non-adopters, low user (<30% usage rate), and high user PCPs (>30% usage rate). Second, we modeled the effect of formulary tier on prescription copayment. Last, we modeled the effect of copayment on adherence (proportion of days covered) to each new medication. Compared with non-adopters, high users of e-prescribing were more likely to prescribe preferred-tier medications (vs. non-preferred tier) when both non-interruptive and interruptive formulary decision support were in place (OR 1.9 [95% CI 1.0-3.4], p = 0.04), but no more likely to prescribe preferred-tier when only non-interruptive formulary decision support was in place (p = 0.90). Preferred-tier claims had only slightly lower mean monthly copayments than non-preferred tier claims (angiotensin receptor blocker: $10.60 versus $11.81, inhaled steroid: $14.86 versus $16.42, p < 0.0001). Medication possession ratio was 8% lower for each $1.00 increase in monthly copayment to the one quarter power (p < 0.0001). However, we detected no significant direct association between formulary decision support usage and adherence. Interruptive formulary decision support shifted prescribing toward preferred tiers, but these medications were only minimally less expensive in the studied patient population. In this context, formulary decision support did not significantly increase adherence. To impact cost-related non-adherence, formulary decision support will likely need to be paired with complementary drug benefit design. Formulary decision support should be studied further, with particular attention to its effect on adherence in the setting of different benefit designs.
Adaptation of superconducting fault current limiter to high-speed reclosing
NASA Astrophysics Data System (ADS)
Koyama, T.; Yanabu, S.
2009-10-01
Using a high temperature superconductor, we constructed and tested a model superconducting fault current limiter (SFCL). The superconductor might break in some cases because of its excessive generation of heat. Therefore, it is desirable to interrupt early the current that flows to superconductor. So, we proposed the SFCL using an electromagnetic repulsion switch which is composed of a superconductor, a vacuum interrupter and a by-pass coil, and its structure is simple. Duration that the current flow in the superconductor can be easily minimized to the level of less than 0.5 cycle using this equipment. On the other hand, the fault current is also easily limited by large reactance of the parallel coil. There is duty of high-speed reclosing after interrupting fault current in the electric power system. After the fault current is interrupted, the back-up breaker is re-closed within 350 ms. So, the electromagnetic repulsion switch should return to former state and the superconductor should be recovered to superconducting state before high-speed reclosing. Then, we proposed the SFCL using an electromagnetic repulsion switch which employs our new reclosing function. We also studied recovery time of the superconductor, because superconductor should be recovered to superconducting state within 350 ms. In this paper, the recovery time characteristics of the superconducting wire were investigated. Also, we combined the superconductor with the electromagnetic repulsion switch, and we did performance test. As a result, a high-speed reclosing within 350 ms was proven to be possible.
Real-time Focused Ultrasound Surgery (FUS) Monitoring Using Harmonic Motion Imaging (HMI)
NASA Astrophysics Data System (ADS)
Maleke, Caroline; Konofagou, Elisa E.
2009-04-01
Monitoring changes in tissue mechanical properties to optimally control thermal exposure is important in thermal therapies. The amplitude-modulated (AM) harmonic motion imaging (HMI) for focused ultrasound (HMIFU) technique is a radiation force technique, which has the capability of tracking tissue stiffness during application of an oscillatory force. The feasibility of HMIFU for assessing mechanical tissue properties has been previously demonstrated. In this paper, a confocal transducer, combining a 4.5 MHz FUS transducer and a 3.3 MHz phased array imaging transducer, was used. The FUS transducer was driven by AM wave at 15 Hz with an acoustic intensity (Ispta) was equal to 1050 W/cm2. A lowpass digital filter was used to remove the spectrum of the higher power beam prior to displacement estimation. The resulting axial tissue displacement was estimated using 1D cross-correlation with a correlation window of 2 mm and a 92.5% overlap. A thermocouple was also used to measure the temperature near the ablated region. 2D HMI-images from six-bovine-liver specimens indicated the onset of coagulation necrosis through changes in amplitude displacement after coagulation due to its simultaneous probing and heating capability. The HMI technique can thus be used to monitor temperature-related stiffness changes of tissues during thermal therapies in real-time, i.e., without interrupting or modifying the treatment protocol.
Real-time Focused Ultrasound Surgery (FUS) Monitoring Using Harmonic Motion Imaging (HMI)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maleke, Caroline; Konofagou, Elisa E.; Department of Radiology, Columbia University, New York, NY
2009-04-14
Monitoring changes in tissue mechanical properties to optimally control thermal exposure is important in thermal therapies. The amplitude-modulated (AM) harmonic motion imaging (HMI) for focused ultrasound (HMIFU) technique is a radiation force technique, which has the capability of tracking tissue stiffness during application of an oscillatory force. The feasibility of HMIFU for assessing mechanical tissue properties has been previously demonstrated. In this paper, a confocal transducer, combining a 4.5 MHz FUS transducer and a 3.3 MHz phased array imaging transducer, was used. The FUS transducer was driven by AM wave at 15 Hz with an acoustic intensity (I{sub spta}) wasmore » equal to 1050 W/cm{sup 2}. A lowpass digital filter was used to remove the spectrum of the higher power beam prior to displacement estimation. The resulting axial tissue displacement was estimated using 1D cross-correlation with a correlation window of 2 mm and a 92.5% overlap. A thermocouple was also used to measure the temperature near the ablated region. 2D HMI-images from six-bovine-liver specimens indicated the onset of coagulation necrosis through changes in amplitude displacement after coagulation due to its simultaneous probing and heating capability. The HMI technique can thus be used to monitor temperature-related stiffness changes of tissues during thermal therapies in real-time, i.e., without interrupting or modifying the treatment protocol.« less
Understanding Emergency Medicine Physicians Multitasking Behaviors Around Interruptions.
Fong, Allan; Ratwani, Raj M
2018-06-11
Interruptions can adversely impact human performance, particularly in fast-paced and high-risk environments such as the emergency department (ED). Understanding physician behaviors before, during, and after interruptions is important to the design and promotion of safe and effective workflow solutions. However, traditional human factors based interruption models do not accurately reflect the complexities of real-world environments like the ED and may not capture multiple interruptions and multitasking. We present a more comprehensive framework for understanding interruptions that is composed of three phases, each with multiple levels: Interruption Start Transition, Interruption Engagement, and Interruption End Transition. This three-phase framework is not constrained to discrete task transitions, providing a robust method to categorize multitasking behaviors around interruptions. We apply this framework in categorizing 457 interruption episodes. 457 interruption episodes were captured during 36 hours of observation. The interrupted task was immediately suspended 348 (76.1%) times. Participants engaged in new self-initiated tasks during the interrupting task 164 (35.9%) times and did not directly resume the interrupted task in 284 (62.1%) interruption episodes. Using this framework provides a more detailed description of the types of physician behaviors in complex environments. Understanding the different types of interruption and resumption patterns, which may have a different impact on performance, can support the design of interruption mitigation strategies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
SEE Transient Response of Crane Interpoint Single Output Point of Load DC-DC Converters
NASA Technical Reports Server (NTRS)
Sanders, Anthony B.; Chen, Dakai; Kim, Hak S.; Phan, Anthony M.
2011-01-01
This study was undertaken to determine the single event effect and transient susceptibility of the Crane Interpoint Maximum Flexible Power (MFP) Single Output Point of Load DC/DC Converters for transient interruptions in the output signal and for destructive and non destructive events induced by exposing it to a heavy ion beam..
Energy Resiliency for Marine Corps Logistics Base Production Plant Barstow
2014-12-01
13 1. Biomass, Landfill Gas, and Biogas ...value in dollar per kilowatts ($/kW) peak of an outage cost obtained from the CDF curve for a specified duration of the interruption” (Giraldez, Booth...length of outages for inclusion in the VEES calculation, we needed to obtain power interruption and circuit reliability data from PPB’s utility
ERIC Educational Resources Information Center
Day, Terence
2015-01-01
Academic continuity planning is an emerging tool for dealing with class cancellation associated with natural disasters, acts of violence and the threat of pandemics. However, academic continuity can also be an issue with respect to less dramatic events, such as power outages, inclement weather, or the temporary unavailability of an instructor,…
Anticipatory control: A software retrofit for current plant controllers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parthasarathy, S.; Parlos, A.G.; Atiya, A.F.
1993-01-01
The design and simulated testing of an artificial neural network (ANN)-based self-adapting controller for complex process systems are presented in this paper. The proposed controller employs concepts based on anticipatory systems, which have been widely used in the petroleum and chemical industries, and they are slowly finding their way into the power industry. In particular, model predictive control (MPC) is used for the systematic adaptation of the controller parameters to achieve desirable plant performance over the entire operating envelope. The versatile anticipatory control algorithm developed in this study is projected to enhance plant performance and lend robustness to drifts inmore » plant parameters and to modeling uncertainties. This novel technique of integrating recurrent ANNs with a conventional controller structure appears capable of controlling complex, nonlinear, and nonminimum phase process systems. The direct, on-line adaptive control algorithm presented in this paper considers the plant response over a finite time horizon, diminishing the need for manual control or process interruption for controller gain tuning.« less
NASA Astrophysics Data System (ADS)
Qiao, Liang; Ma, Zi-Guang; Chen, Hong; Wu, Hai-Yan; Chen, Xue-Fang; Yang, Hao-Jun; Zhao, Bin; He, Miao; Zheng, Shu-Wen; Li, Shu-Ti
2016-10-01
In this study, the influence of multiple interruptions with trimethylindium (TMIn)-treatment in InGaN/GaN multiple quantum wells (MQWs) on green light-emitting diode (LED) is investigated. A comparison of conventional LEDs with the one fabricated with our method shows that the latter has better optical properties. Photoluminescence (PL) full-width at half maximum (FWHM) is reduced, light output power is much higher and the blue shift of electroluminescence (EL) dominant wavelength becomes smaller with current increasing. These improvements should be attributed to the reduced interface roughness of MQW and more uniformity of indium distribution in MQWs by the interruptions with TMIn-treatment. Project supported by the National Natural Science Foundation of China (Grant Nos. 11204360 and 61210014), the Science and Technology Planning Projects of Guangdong Province, China (Grant Nos. 2014B050505020, 2015B010114007, and 2014B090904045), the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20134407110008), the Guangzhou Municipal Science and Technology Project of Guangdong Province, China (Grant No. 2016201604030027), and the Zhongshan Science and Technology Project of Guangdong Province, China (Grant No. 2013B3FC0003).
Tuning Linux to meet real time requirements
NASA Astrophysics Data System (ADS)
Herbel, Richard S.; Le, Dang N.
2007-04-01
There is a desire to use Linux in military systems. Customers are requesting contractors to use open source to the maximal possible extent in contracts. Linux is probably the best operating system of choice to meet this need. It is widely used. It is free. It is royalty free, and, best of all, it is completely open source. However, there is a problem. Linux was not originally built to be a real time operating system. There are many places where interrupts can and will be blocked for an indeterminate amount of time. There have been several attempts to bridge this gap. One of them is from RTLinux, which attempts to build a microkernel underneath Linux. The microkernel will handle all interrupts and then pass it up to the Linux operating system. This does insure good interrupt latency; however, it is not free [1]. Another is RTAI, which provides a similar typed interface; however, the PowerPC platform, which is used widely in real time embedded community, was stated as "recovering" [2]. Thus this is not suited for military usage. This paper provides a method for tuning a standard Linux kernel so it can meet the real time requirement of an embedded system.
NASA Astrophysics Data System (ADS)
Shurupov, A. V.; Zavalova, V. E.; Kozlov, A. V.; Shurupov, M. A.; Povareshkin, M. N.; Kozlov, A. A.; Shurupova, N. P.
2018-01-01
Experimental models of microsecond duration powerful generators of current pulses on the basis of explosive magnetic generators and voltage impulse generator have been developed for the electromagnetic pulse effects on energy facilities to verify their stability. Exacerbation of voltage pulse carried out through the use of electro explosive current interrupter made of copper wires with diameters of 80 and 120 μm. Experimental results of these models investigation are represented. Voltage fronts about 100 ns and the electric field strength of 800 kV/m are registered.
O'Sullivan, G.A.; O'Sullivan, J.A.
1999-07-27
In one embodiment, a power processor which operates in three modes: an inverter mode wherein power is delivered from a battery to an AC power grid or load; a battery charger mode wherein the battery is charged by a generator; and a parallel mode wherein the generator supplies power to the AC power grid or load in parallel with the battery. In the parallel mode, the system adapts to arbitrary non-linear loads. The power processor may operate on a per-phase basis wherein the load may be synthetically transferred from one phase to another by way of a bumpless transfer which causes no interruption of power to the load when transferring energy sources. Voltage transients and frequency transients delivered to the load when switching between the generator and battery sources are minimized, thereby providing an uninterruptible power supply. The power processor may be used as part of a hybrid electrical power source system which may contain, in one embodiment, a photovoltaic array, diesel engine, and battery power sources. 31 figs.
O'Sullivan, George A.; O'Sullivan, Joseph A.
1999-01-01
In one embodiment, a power processor which operates in three modes: an inverter mode wherein power is delivered from a battery to an AC power grid or load; a battery charger mode wherein the battery is charged by a generator; and a parallel mode wherein the generator supplies power to the AC power grid or load in parallel with the battery. In the parallel mode, the system adapts to arbitrary non-linear loads. The power processor may operate on a per-phase basis wherein the load may be synthetically transferred from one phase to another by way of a bumpless transfer which causes no interruption of power to the load when transferring energy sources. Voltage transients and frequency transients delivered to the load when switching between the generator and battery sources are minimized, thereby providing an uninterruptible power supply. The power processor may be used as part of a hybrid electrical power source system which may contain, in one embodiment, a photovoltaic array, diesel engine, and battery power sources.
Why power matters: creating a foundation of mutual support in couple relationships.
Knudson-Martin, Carmen
2013-03-01
Research shows that equal power helps couples create intimacy and relationship success. However, though couples increasingly desire equal relationships, cultural models of mutual support are not well developed. Clinicians often approach heterosexual couple therapy as though partners are inherently equal, thus reinforcing unacknowledged gender inequities. This article examines research that shows why power imbalances are destructive to intimate relationships and focuses on four gender-related aspects of mutual support: (a) shared relational responsibility, (b) mutual vulnerability, (c) mutual attunement, and (d) shared influence. Case examples illustrate how socio-emotional attunement, interrupting the flow of power, and introducing alternative relational experience help couple therapists identify and address power disparities in these important relational processes. Encouraging the powerful person to take relational initiative and introducing alternative gender discourse are especially important. © FPI, Inc.
NASA Astrophysics Data System (ADS)
Lamour, B. G.; Harris, R. T.; Roberts, A. G.
2010-06-01
Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.
Rivera, A Joy
2014-05-01
The purpose of this study was to understand the cognitive processes underlying nurses' decision to interrupt other nurses. The Institute of Medicine (2000) reported that interruptions are likely contributors to medical errors. Unfortunately, the research to date has been quite homogenous, focusing only on the healthcare provider being interrupted, ignoring the true complexities of interruptions. This study took a socio-technical approach being the first to examine interruptions from the viewpoint of the interrupting nurse. Over 15 h of observations and 10 open-ended interviews with expert nurses in a Neuroscience Surgical Intensive Care Unit were conducted. It was found that nurses conduct a quick cost-benefit assessment to determine the interruptibility of other nurses and whether an interruption is value-added vs. non-value added. To complete the assessment, nurses consider several conditional factors related to the interruptee, the interrupter, and the nature of the interruption content, and different potential consequences of the interruption. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Liang, Jiejunyi; Yang, Haitao; Wu, Jinglai; Zhang, Nong; Walker, Paul D.
2018-05-01
To improve the overall efficiency of electric vehicles and guarantee the driving comfort and vehicle drivability under the concept of simplifying mechanism complexity and minimizing manufacturing cost, this paper proposes a novel clutchless power-shifting transmission system with shifting control strategy and power sharing control strategy. The proposed shifting strategy takes advantage of the transmission architecture to achieve power-on shifting, which greatly improves the driving comfort compared with conventional automated manual transmission, with a bump function based shifting control method. To maximize the overall efficiency, a real-time power sharing control strategy is designed to solve the power distribution problem between the two motors. Detailed mathematical model is built to verify the effectiveness of the proposed methods. The results demonstrate the proposed strategies considerably improve the overall efficiency while achieve non-interrupted power-on shifting and maintain the vehicle jerk during shifting under an acceptable threshold.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Choong Koo; Park, Hyo Jeong; Kim, In Chool
Reserve margins of Korea Electric Power Corporation (KEPCO) was 12% in 1993, however it was reduced to less than 3% in the summer of 1994 due to increase of electric power consumption caused by life style change based on economic growth. Therefore stable supply of electric power to industrial plant was threatened during last summer`s peak. The process of semiconductor manufacturing is very precious and full processing time reaches several months. Furthermore interruption of power supply to the process causes abortion of every product in the process. Therefore, power failure of less than one (1) second, may result in enormousmore » loss of capital. In order to protect disaster caused by power shortage during summer peaks. Samsung Electronics Co., Ltd (SEC) planned to construct LNG combined cycle power plant for the Klheung semiconductor plant which is the world`s leading maker of dynamic random access memory (DRAM) chips.« less
Promise, pitfalls of rate reform shown in Vermont experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-03-01
Both utilities and customers are unhappy with the way existing rate structures are handling rapidly rising fixed plant expenses and operating costs. Results of an experiment by Green Mountain Power in Vermont are discussed. The residential sector one-year study tested six rates: an off-peak rate, an interruptible rate, a peak-kilowatt demand rate, a three-part demand rate, an inverted demand rate, and a contract demand rate. The most successful of the kilowatt-related rates was the peak demand rate, and the most effective rate was probably the interruptible rate. The off-peak rate provided some savings for all who tried it, although theremore » are some who would have lost money in comparison to the conventional rate. The other three rate experiments proved unsuccessful because customers could not adapt to them. (MCW)« less
Women and Nature: Using Memory-Work to Rethink Our Relationship to the Natural World
ERIC Educational Resources Information Center
Kaufman, Judith S.; Ewing, Margaret S.; Hyle, Adrienne E.; Montgomery, Diane; Self, Patricia A.
2006-01-01
Memory-work is a feminist research methodology that is used by research collectives to study socialization within the dominant values that make up a particular culture. The power of memory-work lies with its potential to interrupt hegemonic ways of seeing and knowing the world. Consequently, it can open up possibilities for individual and social…
Code of Federal Regulations, 2011 CFR
2011-01-01
... electrically heated, gas-heated, or oil-heated water. The water consumption for the sensor normal cycle, V, is.... 1.16Truncated sensor heavy response means the sensor heavy response interrupted to eliminate the power-dry feature after the termination of the last rinse operation. 1.17Truncated sensor light response...
Code of Federal Regulations, 2010 CFR
2010-01-01
... electrically heated, gas-heated, or oil-heated water. The water consumption for the sensor normal cycle, V, is.... 1.16Truncated sensor heavy response means the sensor heavy response interrupted to eliminate the power-dry feature after the termination of the last rinse operation. 1.17Truncated sensor light response...
Can Teens Really Do It All?: Techno-Multitasking, Learning, and Performance
ERIC Educational Resources Information Center
Bradley, Karen
2011-01-01
Many adults and students today think of themselves as excellent multitaskers--switching from task to task or from task to play in a nanosecond. Yet the pings and tweets their devices emit interrupt them in ways that are more problematic than they think. One of the powerful myths in the culture today is that multitasking is efficient for work or…
ERIC Educational Resources Information Center
Lukes, Marguerite
2011-01-01
This study explores the potential of native language literacy instruction for adult immigrant English language learners who have limited formal schooling or have had interruptions in their formal education. By examining 3 programs that provide native language literacy in combination with English as a second language (ESL) instruction, this study…
The Effects of Noxious Subliminal Suggestion upon Smoking Attitudes and Behavior.
ERIC Educational Resources Information Center
Dutto, Franklin N.; Galli, Nicholas
The efforts of smoking cessation programs have met with various degrees of success and fresh approaches to the problem are needed. An innovative technique that interrupts the psychogenic drives of smokers was employed to determine the effect of noxious subliminal suggestion on smoking attitudes and behavior. Adult smokers (N=60) were shown…
An eye movement analysis of the effect of interruption modality on primary task resumption.
Ratwani, Raj; Trafton, J Gregory
2010-06-01
We examined the effect of interruption modality (visual or auditory) on primary task (visual) resumption to determine which modality was the least disruptive. Theories examining interruption modality have focused on specific periods of the interruption timeline. Preemption theory has focused on the switch from the primary task to the interrupting task. Multiple resource theory has focused on interrupting tasks that are to be performed concurrently with the primary task. Our focus was on examining how interruption modality influences task resumption.We leverage the memory-for-goals theory, which suggests that maintaining an associative link between environmental cues and the suspended primary task goal is important for resumption. Three interruption modality conditions were examined: auditory interruption with the primary task visible, auditory interruption with a blank screen occluding the primary task, and a visual interruption occluding the primary task. Reaction time and eye movement data were collected. The auditory condition with the primary task visible was the least disruptive. Eye movement data suggest that participants in this condition were actively maintaining an associative link between relevant environmental cues on the primary task interface and the suspended primary task goal during the interruption. These data suggest that maintaining cue association is the important factor for reducing the disruptiveness of interruptions, not interruption modality. Interruption-prone computing environments should be designed to allow for the user to have access to relevant primary task cues during an interruption to minimize disruptiveness.
Respiratory sound recordings for detection of sleep apnea
NASA Astrophysics Data System (ADS)
Waldemark, Karina E.; Agehed, Kenneth I.; Lindblad, Thomas
1999-03-01
Sleep apnea is characterized by frequent prolonged interruptions of breathing during sleep. This syndrome causes severe sleep disorders and is often responsible for development of other diseases such as heart problems, high blood pressure and daytime fatigue, etc. After diagnosis, sleep apnea is often successfully treated by applying positive air pressure (CPAP) to the mouth and nose. Although effective, the (CPAP) equipment takes up a lot of space and the connected mask causes a lot of inconvenience for the patients. This raised interest in developing new techniques for treatment of sleep apnea syndrome. Several studies indicated that electrical stimulation of the hypoglossal nerve and muscle in the tongue may be a useful method for treating patients with severe sleep apnea. In order to be able to successfully prevent the occurrence of apnea it is necessary to have some technique for early and fast on-line detection or prediction of the apnea events. This paper suggests using measurements of respiratory airflow (mouth temperature). The signal processing for this task includes the use of a window short-FFT technique and uses an artificial back propagation neural net to model or predict the occurrence of apneas. The results show that early detection of respiratory interruption is possible and that the delay time for this is small.
Improving the effectiveness of an interruption lag by inducing a memory-based strategy.
Morgan, Phillip L; Patrick, John; Tiley, Leyanne
2013-01-01
The memory for goals model (Altmann & Trafton, 2002) posits the importance of a short delay (the 'interruption lag') before an interrupting task to encode suspended goals for retrieval post-interruption. Two experiments used the theory of soft constraints (Gray, Simms, Fu & Schoelles, 2006) to investigate whether the efficacy of an interruption lag could be improved by increasing goal-state access cost to induce a more memory-based encoding strategy. Both experiments used a copying task with three access cost conditions (Low, Medium, and High) and a 5-s interruption lag with a no lag control condition. Experiment 1 found that the participants in the High access cost condition resumed more interrupted trials and executed more actions correctly from memory when coupled with an interruption lag. Experiment 2 used a prospective memory test post-interruption and an eyetracker recorded gaze activity during the interruption lag. The participants in the High access cost condition with an interruption lag were best at encoding target information during the interruption lag, evidenced by higher scores on the prospective memory measure and more gaze activity on the goal-state during the interruption lag. Theoretical and practical issues regarding the use of goal-state access cost and an interruption lag are discussed. Copyright © 2012. Published by Elsevier B.V.
Do interruptions affect quality of work?
Foroughi, Cyrus K; Werner, Nicole E; Nelson, Erik T; Boehm-Davis, Deborah A
2014-11-01
The aim of this study was to determine if interruptions affect the quality of work. Interruptions are commonplace at home and in the office. Previous research in this area has traditionally involved time and errors as the primary measures of disruption. Little is known about the effect interruptions have on quality of work. Fifty-four students outlined and wrote three essays using a within-subjects design. During Condition 1, interruptions occurred while participants were outlining. During Condition 2, interruptions occurred while they were writing. No interruptions occurred in Condition 3. Quality of work was significantly reduced in both interruption conditions when compared to the non-interruption condition. The number of words produced was significantly reduced when participants were interrupted while writing the essay but not when outlining the essay. This research represents a crucial first step in understanding the effect interruptions have on quality of work. Our research suggests that interruptions negatively impact quality of work during a complex, creative writing task. Since interruptions are such a prevalent part of daily life, more research needs to be conducted to determine what other tasks are negatively impacted. Moreover, the underlying mechanism(s) causing these decrements needs to be identified. Finally, strategies and systems need to be designed and put in place to help counteract the decline in quality of work caused by interruptions.
Deformation of contact surfaces in a vacuum interrupter after high-current interruptions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Haoran; Wang, Zhenxing, E-mail: zxwang@xjtu.edu.cn; Zhou, Zhipeng
2016-08-07
In a high-current interruption, the contact surface in a vacuum interrupter might be severely damaged by constricted vacuum arcs causing a molten area on it. As a result, a protrusion will be initiated by a transient recovery voltage after current zero, enhancing the local electric field and making breakdowns occur easier. The objective of this paper is to simulate the deformation process on the molten area under a high electric field by adopting the finite element method. A time-dependent Electrohydrodynamic model was established, and the liquid-gas interface was tracked by the level-set method. From the results, the liquid metal canmore » be deformed to a Taylor cone if the applied electric field is above a critical value. This value is correlated to the initial geometry of the liquid metal, which increases as the size of the liquid metal decreases. Moreover, the buildup time of a Taylor cone obeys the power law t = k × E{sup −3}, where E is the initial electric field and k is a coefficient related to the material property, indicating a temporal self-similar characteristic. In addition, the influence of temperature has little impact on the deformation but has great impact on electron emission. Finally, the possible reason to initiate a delayed breakdown is associated with the deformation. The breakdown does not occur immediately when the voltage is just applied upon the gap but is postponed to several milliseconds later when the tip is formed on the liquid metal.« less
Investigating Interruptions: Implications for Flightdeck Performance
NASA Technical Reports Server (NTRS)
Latorella, Kara A.
1999-01-01
A fundamental aspect of multiple task management is attending to new stimuli and integrating associated task requirements into an ongoing task set; this is "interruption management" (IM). Anecdotal evidence and field studies indicate the frequency and consequences of interruptions, however experimental investigations of mechanisms influencing IM are scarce. Interruptions on commercial flightdecks are numerous, of various forms, and have been cited as contributing factors in many aviation incident and accident reports. This research grounds an experimental investigation of flightdeck interruptions in a proposed IM stage model. This model organizes basic research, identifies influencing mechanisms, and suggests appropriate dependent measures for IM. Fourteen airline pilots participated in a flightdeck simulation experiment to investigate the general effects of performing an interrupting task and interrupted procedure, and the effects of specific task factors: (1) modality; (2) embeddedness, or goal-level, of an interruption; (3) strength of association, or coupling-strength, between interrupted tasks; (4) semantic similarity; and (5) environmental stress. General effects of interruptions were extremely robust. All individual task factors significantly affected interruption management, except "similarity." Results extend the Interruption Management model, and are interpreted for their implications for interrupted flightdeck performance and intervention strategies for mitigating their effects on the flightdeck.
Kolin, Alexander; Steele, James R.; Imai, James S.; Macalpin, Rex N.
1974-01-01
A combination of deformable flow probes of negligible lateral dimensions with an electronic circuit capable of providing a prolonged plateau of dB/dt = 0 and of sampling the flow signal at the end of this interval permits electromagnetic measurement of blood flow with a reliable zero base line secured by switching off the magnet. An extracorporeal magnet provides the magnetic field. The flow transducer is introduced into the vascular system percutaneously through a standard angiographic catheter by conventional technique. The idea of the current generator can be described as “principle of interrupted resonance.” The current wave form can be described as a sequence of disconnected bisected sine waves joined at the apices by horizontal current plateaus where di/dt is strictly zero. Images PMID:4275395
Ares, Manuel; Bruns, Peter J.
1978-01-01
A dominant mutation at a new locus affecting resistance to cycloheximide has been isolated by exploiting a synergistic relationship with a previously known mutation for cycloheximide resistance in Tetrahymena. The new mutation (ChxB) was induced in a line homozygous for ChxA and was recovered from that background by a new technique termed interrupted genomic exclusion. Segregation data from the interrupted genomic exclusion suggest that ChxA and ChxB are separate, linked loci showing 30% recombination. Minimal lethal doses of cycloheximide for the four possible combinations of the wild-type and mutant alleles of these two genes are: wild type 6 µg/ml, ChxA 125 µg/ml, ChxB 10 µg/ml, ChxA-ChxB 175 µg/ml. PMID:730051
Flynn, Fran; Evanish, Julie Q; Fernald, Josephine M; Hutchinson, Dawn E; Lefaiver, Cheryl
2016-08-01
Because of the high frequency of interruptions during medication administration, the effectiveness of strategies to limit interruptions during medication administration has been evaluated in numerous quality improvement initiatives in an effort to reduce medication administration errors. To evaluate the effectiveness of evidence-based strategies to limit interruptions during scheduled, peak medication administration times in 3 progressive cardiac care units (PCCUs). A secondary aim of the project was to evaluate the impact of limiting interruptions on medication errors. The percentages of interruptions and medication errors before and after implementation of evidence-based strategies to limit interruptions were measured by using direct observations of nurses on 2 PCCUs. Nurses in a third PCCU served as a comparison group. Interruptions (P < .001) and medication errors (P = .02) decreased significantly in 1 PCCU after implementation of evidence-based strategies to limit interruptions. Avoidable interruptions decreased 83% in PCCU1 and 53% in PCCU2 after implementation of the evidence-based strategies. Implementation of evidence-based strategies to limit interruptions in PCCUs decreases avoidable interruptions and promotes patient safety. ©2016 American Association of Critical-Care Nurses.
NASA Astrophysics Data System (ADS)
Ballan, Michele; Manzolaro, Mattia; Meneghetti, Giovanni; Andrighetto, Alberto; Monetti, Alberto; Bisoffi, Giovanni; Prete, Gianfranco
2016-06-01
The SPES project at INFN-LNL aims at the production of neutron-rich Radioactive Ion Beams (RIBs) using the ISOL (Isotope Separation On Line) technique. A 40 MeV 200 μA proton beam will directly impinge a uranium carbide target, generating approximately 1013 fissions per second. The target system is installed under vacuum inside a water-cooled chamber, and have to maintain high working temperatures, close to 2000 °C. During operation the proton beam provides the heating power required to keep the target at the desired temperature level. As a consequence, its characteristics have to be strictly controlled in order to avoid undesired overheating. According to the original design of the control system, the proton beam can be suddenly interrupted in case of out of range vacuum or cooling water flow levels. With the aim to improve the reliability of the control system a set of temperature sensors has been installed close to the target. Their types and installation positions were defined taking into consideration the detailed information coming from a dedicated thermal-electric model that allowed to investigate the most critical and inaccessible target hot-spots. This work is focused on the definition and experimental validation of the aforementioned numerical model. Its results were used to appropriately install two type C thermocouples, a PT100 thermo-resistance and a residual primary beam current detector. In addition the numerical model will be used for the definition of appropriate thresholds for each installed temperature sensor, since it allows to define a relationship between the locally measured values with the overall calculated temperature field. In case of over temperatures the monitoring system will send warning signals or in case interrupt the proton beam.
Cane, James E; Cauchard, Fabrice; Weger, Ulrich W
2012-01-01
Two experiments examined how interruptions impact reading and how interruption lags and the reader's spatial memory affect the recovery from such interruptions. Participants read paragraphs of text and were interrupted unpredictably by a spoken news story while their eye movements were monitored. Time made available for consolidation prior to responding to the interruption did not aid reading resumption. However, providing readers with a visual cue that indicated the interruption location did aid task resumption substantially in Experiment 2. Taken together, the findings show that the recovery from interruptions during reading draws on spatial memory resources and can be aided by processes that support spatial memory. Practical implications are discussed.
Present Status of Power Circuit Breaker and its Future
NASA Astrophysics Data System (ADS)
Yoshioka, Yoshio
Gas circuit breaker and vacuum circuit breaker are the 2 main types of circuit breaker used in extra high voltage and medium voltage networks. After reviewing the history of these circuit breakers, their present status and technologies are described. As for future technology, computation of interrupting phenomena, SF6 gas less apparatus and expectation of the high voltage vacuum circuit breaker are discussed.
Interruption as a test of the user-computer interface
NASA Technical Reports Server (NTRS)
Kreifeldt, J. G.; Mccarthy, M. E.
1981-01-01
In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.
NASA Astrophysics Data System (ADS)
Kondratjevs, K.; Zabasta, A.; Selmanovs-Pless, V.
2016-02-01
In recent years, there has been significant research focus that revolves around harvesting and minimising energy consumption by wireless sensor network nodes. When a sensor node is depleted of energy, it becomes unresponsive and disconnected from the network that can significantly influence the performance of the whole network. The purpose of the present research is to create a power supply management module in order to provide stable operating voltage for autonomous operations of radio signal repeaters, sensors or gateways of WSN. The developed management module is composed of a solar panel, lithium battery and power supply management module. The novelty of the research is the management module, which ensures stable and uninterrupted operations of electronic equipment in various power supply modes in different situations, simultaneously ensuring energy protection and sustainability of the module components. The management module is able to provide power supply of 5 V for electronics scheme independently, without power interruption switching between power sources and power flows in different directions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasser, D.W.
1978-03-01
EASI (Estimate of Adversary Sequence Interruption) is an analytical technique for measuring the effectiveness of physical protection systems. EASI Graphics is a computer graphics extension of EASI which provides a capability for performing sensitivity and trade-off analyses of the parameters of a physical protection system. This document reports on the implementation of EASI Graphics and illustrates its application with some examples.
White Paper: A Defect Prioritization Method Based on the Risk Priority Number
2013-11-01
adapted The Failure Modes and Effects Analysis ( FMEA ) method employs a measurement technique called Risk Priority Number (RPN) to quantify the...Up to an hour 16-60 1.5 Brief Interrupt 0-15 1 Table 1 – Time Scaling Factors In the FMEA formulation, RPN is a product of the three categories
NASA Astrophysics Data System (ADS)
Koyama, Tomonori; Kaiho, Katsuyuki; Yamaguchi, Iwao; Yanabu, Satoru
Using a high-temperature superconductor, we constructed and tested a model superconducting fault current limiter (SFCL). The superconductor and vacuum interrupter as the commutation switch were connected in parallel using a bypass coil. When the fault current flows in this equipment, the superconductor is quenched and the current is then transferred to the parallel coil due to the voltage drop in the superconductor. This large current in the parallel coil actuates the magnetic repulsion mechanism of the vacuum interrupter and the current in the superconductor is broken. Using this equipment, the current flow time in the superconductor can be easily minimized. On the other hand, the fault current is also easily limited by large reactance of the parallel coil. This system has many merits. So, we introduced to electromagnetic repulsion switch. There is duty of high speed re-closing after interrupting fault current in the electrical power system. So the SFCL should be recovered to superconducting state before high speed re-closing. But, superconductor generated heat at the time of quench. It takes time to recover superconducting state. Therefore it is a matter of recovery time. In this paper, we studied recovery time of superconductor. Also, we proposed electromagnetic repulsion switch with reclosing system.
A No-Arc DC Circuit Breaker Based on Zero-Current Interruption
NASA Astrophysics Data System (ADS)
Xiang, Xuewei; Chai, Jianyun; Sun, Xudong
2017-05-01
A dc system has no natural current zero-crossing point, so a dc arc is more difficult to extinguish than an ac arc. In order to effectively solve the problem of the dc arc, this paper proposes a dc circuit breaker (DCCB) capable of implementing a no-arc interruption. The proposed DCCB includes a main branch consisting of a mechanical switch, a diode and a current-limiting inductor, a semi-period resonance circuit consisting of a diode, an inductor and a capacitor, and a buffer branch consisting of a capacitor, a thyristor and a resistor. The mechanical switch is opened in a zero-current state, and the overvoltage caused by the counter electromotive force of the inductor does not exist. Meanwhile, the capacitor has a buffering effect on the voltage. The rising of the voltage of the mechanical switch is slower than the rising of the insulating strength of a contact gap of the mechanical switch, resulting in the contact gap not able to be broken down. Thus, the arc cannot be generated. The simulation results show that the proposed DCCB does not generate the arc in the interruption process, the rise rate of the short circuit current can be effectively limited, and the short circuit fault point can be rapidly isolated from the dc power supply.
The interrupted power law and the size of shadow banking.
Fiaschi, Davide; Kondor, Imre; Marsili, Matteo; Volpati, Valerio
2014-01-01
Using public data (Forbes Global 2000) we show that the asset sizes for the largest global firms follow a Pareto distribution in an intermediate range, that is "interrupted" by a sharp cut-off in its upper tail, where it is totally dominated by financial firms. This flattening of the distribution contrasts with a large body of empirical literature which finds a Pareto distribution for firm sizes both across countries and over time. Pareto distributions are generally traced back to a mechanism of proportional random growth, based on a regime of constant returns to scale. This makes our findings of an "interrupted" Pareto distribution all the more puzzling, because we provide evidence that financial firms in our sample should operate in such a regime. We claim that the missing mass from the upper tail of the asset size distribution is a consequence of shadow banking activity and that it provides an (upper) estimate of the size of the shadow banking system. This estimate-which we propose as a shadow banking index-compares well with estimates of the Financial Stability Board until 2009, but it shows a sharper rise in shadow banking activity after 2010. Finally, we propose a proportional random growth model that reproduces the observed distribution, thereby providing a quantitative estimate of the intensity of shadow banking activity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, Kevin; Tuffner, Frank; Elizondo, Marcelo
Regulated electricity utilities are required to provide safe and reliable service to their customers at a reasonable cost. To balance the objectives of reliable service and reasonable cost, utilities build and operate their systems to operate under typical historic conditions. As a result, when abnormal events such as major storms or disasters occur, it is not uncommon to have extensive interruptions in service to the end-use customers. Because it is not cost effective to make the existing electrical infrastructure 100% reliable, society has come to expect disruptions during abnormal events. However, with the increasing number of abnormal weather events, themore » public is becoming less tolerant of these disruptions. One possible solution is to deploy microgrids as part of a coordinated resiliency plan to minimize the interruption of power to essential loads. This paper evaluates the feasibility of using microgrids as a resiliency resource, including their possible benefits and the associated technical challenges. A use-case of an operational microgrid is included.« less
NASA Technical Reports Server (NTRS)
Brush, A. S.; Phillips, R. L.
1991-01-01
NASA Lewis Research Center and associated contractors have conducted a program to assess the potential requirements for a high-current switch to conceptually design a switch using the best existing technology, and to build and demonstrate a breadboard which meets the requirements. The result is the high current remote bus isolator (HRBI). The HRBI is rated at 180 V dc, 335 A continuous with a 1200 A interrupt rating. It also incorporates remote-control and protective features called for by the Space Station Freedom PMAD dc test bed design. Two breadboard 335 A circuit breakers were built and tested that demonstrate a promising concept of paralleled current-limiting modules. The units incorporated all control and protective features required by advanced aerospace power systems. Component stresses in each unit were determined by design, and are consistent with a life of many thousands of fault operations.
Causes and occurrences of interruptions during ED triage.
Johnson, Kimberly D; Motavalli, Michele; Gray, Dean; Kuehn, Connie
2014-09-01
Interruptions have been shown to cause errors and delays in the treatment of emergency patients and pose a real threat during the triage process. Missteps during the triage assessment can send a patient down the wrong treatment path and lead to delays. The purpose of this project was to identify the types and frequency of interruptions during the ED triage interview process. A focus group of emergency nurses was organized to identify the types of interruptions that commonly occur during the triage interview. These interruptions would be validated through observations in triage. A tally sheet was developed and implemented to determine how often each interruption occurred during an 8-hour shift. Triage nurses completed the tally sheets while working the first shift (7 am to 3 pm). This shift was selected because patient intake in the US Department of Veterans Affairs Emergency Department is highest during this time. The categories of interruptions identified included provision of conveniences to visitors, coworker-related interruptions, patient care-related interruptions, locating of family members in the emergency department, and other miscellaneous interruptions. Tally sheets were completed by the triage nurses during 10 shifts. On average, triage nurses were interrupted 48.2 times during an 8-hour shift (7 interruptions per hour). After reviewing the data, we found that only 22% of interruptions were related to patient care. More frequently, the causes of interruptions were not related to patient care: opening the door (33%), providing conveniences to visitors (21%), waiting patients or family members asking "How much longer?" (14%), and other causes (10%). Frequent interruptions can interfere with concentration and may affect patient care. Non-patient care-related interruptions not only can be frustrating to the triage nurse but also can be offensive to triage patients; they ultimately delay care and may even affect the quality of care. However, because scarce research is available regarding interruptions during ED triage, the effects on patient outcomes are unclear. Additional research needs to be conducted to explore the causes and effects of interruptions to the triage process. Copyright © 2014 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
Evaluation and Impact of Workflow Interruptions During Robot-assisted Surgery.
Allers, Jenna C; Hussein, Ahmed A; Ahmad, Nabeeha; Cavuoto, Lora; Wing, Joseph F; Hayes, Robin M; Hinata, Nobuyuki; Bisantz, Ann M; Guru, Khurshid A
2016-06-01
To analyze and categorize causes for interruptions during robot-assisted surgery. We analyzed 10 robot-assisted prostatectomies that were performed by 3 surgeons from October 2014 to June 2015. Interruptions to surgery were defined in terms of duration, stage of surgery, personnel involved, reasons, and impact of the interruption on the surgical workflow. The main reasons for interruptions included the following: console surgeons switching (29%); preparation of the surgical equipment, such as cleaning or changing the camera (29%) or an instrument (27%); or when a suture, stapler, or clip was needed (12%). The most common interruption duration was 10-29 seconds (47.6%), and the least common interruption duration was greater than 90 seconds (3.6%). Additionally, about 14% of the interruptions were considered avoidable, whereas the remaining 86% of interruptions were necessary for surgery. By identifying and analyzing interruptions, we can develop evidence-based strategies to improve operating room efficiency, lower costs, and advance patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.
Assessment of teacher interruptions on learners during oral case presentations.
Yang, Glen; Chin, Rachel
2007-06-01
Studies have only recently begun to investigate the effects of interruptions on physicians in the emergency department (ED). To determine the frequency and nature of interruptions by the training physician that occur when medical trainees do oral case presentations (OCPs) in the ED. This was an observational study. Learner OCPs to attending emergency physicians were observed in the ED of an urban Level 1 trauma center at a major teaching hospital. A single investigator followed attending physicians blinded to the study objective in a nonrandomized convenience sampling of all ED shifts, recording information regarding teacher interruptions during new patient presentations. Learners completed a brief questionnaire after each OCP. A total of 196 OCPs were observed. The mean (+/-SD) duration of OCPs was 3.30 (+/-1.85) minutes, and the mean (+/-SD) number of interruptions was 0.75 (+/-0.60) per minute and 2.49 (+/-1.95) per OCP. The number of interruptions (per OCP) and duration of OCP varied by learner level of training, with more experienced learners giving shorter presentations and being interrupted less often. Frequency (per minute) of interruptions did not vary by learner level. In 40.3% of OCPs, attending physicians interrupted to give an assessment and/or a plan before the learner had done so, but 8.3% of interrupted learners believed that teacher interruptions were "disruptive" to their OCP. Attending emergency physicians frequently interrupt learners during new patient OCPs, with the number of interruptions varying by learner level of training. Teacher interruptions appear to have minimal, if any, detrimental effect on the perceived effectiveness of OCPs as a learning experience.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator regulator with a battery back-up power supply and microprocessor control system is also described. PMID:24442209
Vaccine refrigeration: thinking outside of the box.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator with a battery back-up power supply and microprocessor control system is also described.
Duron, J-B; Nguyen, P S; Levet, Y; Bardot, J; Aiach, G
2014-12-01
Overprojected tip is a pretty usual request not easy to manage. Preop analysis is crucial in order to evaluate tip support and skin thickness and ability to retract. For example, if the skin is very thick and has poor chance to retract, the surgeon should be very careful in the tip projection decreasing to avoid a skin pollybeak deformity. In such cases, he has to analyze the facial proportions, especially other areas projection (radix, dorsum and chin) and think about augmenting them to balance the profile rather than decreasing tip projection. Correction should always be conducted incrementally, starting with weakening the tip support mechanisms and, only if necessary, continue with alar cartilage interruption. This can be performed on many areas (lateral cruras, domes, medial cruras) and with several techniques (resection or interruption+overlapping). Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Solvoll, Terje; Arntsen, Harald; Hartvigsen, Gunnar
2017-01-01
Surveys and research show that mobile communication systems in hospital settings are old and cause frequent interruptions. In the quest to remedy this, an Android based communication system called CallMeSmart tries to encapsulate most of the frequent communication into one hand held device focusing on reducing interruptions and at the same time make the workday easier for healthcare workers. The objective of CallMeSmart is to use context-awareness techniques to automatically monitor the availability of physicians' and nurses', and use this information to prevent or route phone calls, text messages, pages and alarms that would otherwise compromise patient care. In this paper, we present the results from interviewing nurses on alarm fatigue and their expectations regarding context-aware alarm handling using CallMeSmart.
Enhanced High Performance Power Compensation Methodology by IPFC Using PIGBT-IDVR
Arumugom, Subramanian; Rajaram, Marimuthu
2015-01-01
Currently, power systems are involuntarily controlled without high speed control and are frequently initiated, therefore resulting in a slow process when compared with static electronic devices. Among various power interruptions in power supply systems, voltage dips play a central role in causing disruption. The dynamic voltage restorer (DVR) is a process based on voltage control that compensates for line transients in the distributed system. To overcome these issues and to achieve a higher speed, a new methodology called the Parallel IGBT-Based Interline Dynamic Voltage Restorer (PIGBT-IDVR) method has been proposed, which mainly spotlights the dynamic processing of energy reloads in common dc-linked energy storage with less adaptive transition. The interline power flow controller (IPFC) scheme has been employed to manage the power transmission between the lines and the restorer method for controlling the reactive power in the individual lines. By employing the proposed methodology, the failure of a distributed system has been avoided and provides better performance than the existing methodologies. PMID:26613101
Linden, Ariel; Yarnold, Paul R
2016-12-01
Single-group interrupted time series analysis (ITSA) is a popular evaluation methodology in which a single unit of observation is being studied, the outcome variable is serially ordered as a time series and the intervention is expected to 'interrupt' the level and/or trend of the time series, subsequent to its introduction. Given that the internal validity of the design rests on the premise that the interruption in the time series is associated with the introduction of the treatment, treatment effects may seem less plausible if a parallel trend already exists in the time series prior to the actual intervention. Thus, sensitivity analyses should focus on detecting structural breaks in the time series before the intervention. In this paper, we introduce a machine-learning algorithm called optimal discriminant analysis (ODA) as an approach to determine if structural breaks can be identified in years prior to the initiation of the intervention, using data from California's 1988 voter-initiated Proposition 99 to reduce smoking rates. The ODA analysis indicates that numerous structural breaks occurred prior to the actual initiation of Proposition 99 in 1989, including perfect structural breaks in 1983 and 1985, thereby casting doubt on the validity of treatment effects estimated for the actual intervention when using a single-group ITSA design. Given the widespread use of ITSA for evaluating observational data and the increasing use of machine-learning techniques in traditional research, we recommend that structural break sensitivity analysis is routinely incorporated in all research using the single-group ITSA design. © 2016 John Wiley & Sons, Ltd.
Testing Of Choiced Ceramics Cutting Tools At Irregular Interrupted Cut
NASA Astrophysics Data System (ADS)
Kyncl, Ladislav; Malotová, Šárka; Nováček, Pavel; Nicielnik, Henryk; Šoková, Dagmar; Hemžský, Pavel; Pitela, David; Holubjak, Jozef
2015-12-01
This article discusses the test of removable ceramic cutting inserts during machining irregular interrupted cut. Tests were performed on a lathe, with the preparation which simulated us the interrupted cut. By changing the number of plates mounted in a preparation it simulate us a regular or irregular interrupted cut. When with four plates it was regular interrupted cut, the remaining three variants were already irregular cut. It was examined whether it will have the irregular interrupted cutting effect on the insert and possibly how it will change life of inserts during irregular interrupted cut (variable delay between shocks).
NASA Astrophysics Data System (ADS)
Shinkai, Takeshi; Koshiduka, Tadashi; Mori, Tadashi; Uchii, Toshiyuki; Tanaka, Tsutomu; Ikeda, Hisatoshi
Current zero measurements are performed for 245kV-50kA-60Hz short line fault (L90) interruption tests with a self-blast interrupting chamber (double volume system) which has the interrupting capability up to 245kV-50kA-50Hz L90. Lower L90 interruption capability is observed for longer arcing time although very high pressure rise is obtained. It may be caused by higher blowing temperature and lower blowing density for longer arcing time. Interruption criteria and a optimization method of the chamber design are discussed to improve L90 interruption capability with it. The new chambers are designed at 245kV-50kA-60Hz to improve gas density in thermal volume for long arcing time. 245kV-50kA-60Hz L90 interruptions are performed with the new chamber. The suggested optimization method is an efficient tool for the self-blast interrupting chamber design although study of computing methods is required to calculate arc conductance around current zero as a direct criterion for L90 interruption capability with higher accuracy.
A Methodological Framework for Model Selection in Interrupted Time Series Studies.
Lopez Bernal, J; Soumerai, S; Gasparrini, A
2018-06-06
Interrupted time series is a powerful and increasingly popular design for evaluating public health and health service interventions. The design involves analysing trends in the outcome of interest and estimating the change in trend following an intervention relative to the counterfactual (the expected ongoing trend if the intervention had not occurred). There are two key components to modelling this effect: first, defining the counterfactual; second, defining the type of effect that the intervention is expected to have on the outcome, known as the impact model. The counterfactual is defined by extrapolating the underlying trends observed before the intervention to the post-intervention period. In doing this, authors must consider the pre-intervention period that will be included, any time varying confounders, whether trends may vary within different subgroups of the population and whether trends are linear or non-linear. Defining the impact model involves specifying the parameters that model the intervention, including for instance whether to allow for an abrupt level change or a gradual slope change, whether to allow for a lag before any effect on the outcome, whether to allow a transition period during which the intervention is being implemented and whether a ceiling or floor effect might be expected. Inappropriate model specification can bias the results of an interrupted time series analysis and using a model that is not closely tailored to the intervention or testing multiple models increases the risk of false positives being detected. It is important that authors use substantive knowledge to customise their interrupted time series model a priori to the intervention and outcome under study. Where there is uncertainty in model specification, authors should consider using separate data sources to define the intervention, running limited sensitivity analyses or undertaking initial exploratory studies. Copyright © 2018. Published by Elsevier Inc.
Brickley, Elizabeth B; Coulibaly, Mamadou; Gabriel, Erin E; Healy, Sara A; Hume, Jen C C; Sagara, Issaka; Traore, Sekou F; Doumbo, Ogobara; Duffy, Patrick E
2016-11-21
Shifting the malaria priorities from a paradigm of control and elimination to a goal of global eradication calls for renewed attention to the interruption of malaria transmission. Sustained progress toward eradication will require both improved understanding of infectious reservoirs and efficient development of novel transmission-blocking interventions, such as rapidly acting and highly efficacious therapeutics and vaccines. Here, we review the direct skin feeding assay (DSF), which has been proposed as a valuable tool for measuring the in natura transmission of malaria parasites from human hosts to mosquito vectors across heterogeneous populations. To capture the methodological breadth of this assay's use, we first systematically review and qualitatively synthesize previously published investigations using DSFs to study malaria transmission in humans. Then, using a recent Phase 1 trial in Mali of the Pfs25H-EPA/Alhydrogel® vaccine candidate (NCT01867463) designed to interrupt Plasmodium falciparum transmission as a case study, we describe the potential opportunities and current limitations of utilizing the endpoints measured by DSF in making early clinical decisions for individually randomized transmission-interrupting intervention candidates. Using simulations based on the data collected in the clinical trial, we demonstrate that the capacity of the DSF to serve as an evaluative tool is limited by the statistical power constraints of the "effective sample size" (i.e. the number of subjects that are capable of transmitting at the time of feeding). Altogether, our findings suggest DSFs have great potential utility for assessing the public health impacts of emerging antimalarial tools, but additional research is needed to address issues of scalability and to establish correlation with community-wide clinical endpoints as well as complementary in vitro measures, such as standard membrane feeding assays. Published by Elsevier Ltd.
Fuel cells provide a revenue-generating solution to power quality problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, J.M. Jr.
Electric power quality and reliability are becoming increasingly important as computers and microprocessors assume a larger role in commercial, health care and industrial buildings and processes. At the same time, constraints on transmission and distribution of power from central stations are making local areas vulnerable to low voltage, load addition limitations, power quality and power reliability problems. Many customers currently utilize some form of premium power in the form of standby generators and/or UPS systems. These include customers where continuous power is required because of health and safety or security reasons (hospitals, nursing homes, places of public assembly, air trafficmore » control, military installations, telecommunications, etc.) These also include customers with industrial or commercial processes which can`t tolerance an interruption of power because of product loss or equipment damage. The paper discusses the use of the PC25 fuel cell power plant for backup and parallel power supplies for critical industrial applications. Several PC25 installations are described: the use of propane in a PC25; the use by rural cooperatives; and a demonstration of PC25 technology using landfill gas.« less
Explaining Democratic Instability in Thailand 1992- 2011
2012-09-01
This development is significant in Thai history, as the return of power to parliamentary government following past coups in Thai history did not lead...1992– 2006 is seen as phases of democratic advancement, a military coup in September 2006 interrupted this development , showing that despite steady...11 Attitudinally, “a democratic regime is consolidated when a strong majority of public opinion holds the belief that democratic procedures and
Optimizing the Prioritization of Natural Disaster Recovery Projects
2007-03-01
collection, and basic utility and infrastructure restoration. The restoration of utilities can include temporary bridges, temporary water and sewage lines...interrupted such as in the case of the 9/11 disaster. Perhaps next time our enemies may target our power grid or water systems. It is the duty of...Transportation The amount and type of transportation infrastructure damage a repair project addresses Water The amount and type of water
Mamykina, Lena; Carter, Eileen J; Sheehan, Barbara; Stanley Hum, R; Twohig, Bridget C; Kaufman, David R
2017-05-01
To examine the apparent purpose of interruptions in a Pediatric Intensive Care Unit and opportunities to reduce their burden with informatics solutions. In this prospective observational study, researchers shadowed clinicians in the unit for one hour at a time, recording all interruptions participating clinicians experienced or initiated, their starting time, duration, and a short description that could help to infer their apparent purpose. All captured interruptions were classified inductively on their source and apparent purpose and on the optimal representational media for fulfilling their apparent purpose. The researchers observed thirty-four one-hour sessions with clinicians in the unit, including 21 nurses and 13 residents and house physicians. The physicians were interrupted on average 11.9 times per hour and interrupted others 8.8 times per hour. Nurses were interrupted 8.6 times per hour and interrupted others 5.1 times per hour. The apparent purpose of interruptions included Information Seeking and Sharing (n=259, 46.3%), Directives and Requests (n=70, 12%), Shared Decision-Making (n=49, 8.8%), Direct Patient Care (n=36, 6.4%), Social (n=71, 12.7%), Device Alarms (n=28, 5%), and Non-Clinical (n=10, 1.8%); 6.6% were not classified due to insufficient description. Of all captured interruptions, 29.5% were classified as being better served with informational displays or computer-mediated communication. Deeper understanding of the purpose of interruptions in critical care can help to distinguish between interruptions that require face-to-face conversation and those that can be eliminated with informatics solutions. The proposed taxonomy of interruptions and representational analysis can be used to further advance the science of interruptions in clinical care. Copyright © 2017 Elsevier Inc. All rights reserved.
Coping with interruptions in clinical nursing-A qualitative study.
Laustsen, Sussie; Brahe, Liselotte
2018-04-01
To gain knowledge on how nurses' cope with interruptions in clinical practice. Interruptions may delay work routines and result in wasted time, disorganised planning and ineffective working procedures, affecting nurses' focus and overview in different ways. Research has identified a growing problem linking errors or adverse events with interruptions. It may affect patient safety if nurses are not paying attention to interruptions. Little is known about how nurses cope with interruptions DESIGN: The study was inspired by ethnographic fieldwork with a hermeneutical phenomenological approach. Observations were performed combined with semi-structured qualitative interviews. Managing interruptions depend on level of competence, working environment, dialogue and matching of expectations, collegial roles and implicit rules. Working procedures impact on how nurses are exposed to unnecessary interruptions. The latter affects overview and the ability to put the foot down and decline being interrupted. Professional competencies for example prioritising, keeping focus and collaborating across disciplines are needed to cope with interruptions. Culture work and matching of expectations are important to reflect on and discuss personal- and group behaviour caused by interruptions. We need to focus on the role of each nurse in the professional team, types of personality and unspoken rules. Professional competencies for example prioritising, keeping focus and cooperating across disciplines are needed to cope with interruptions. Coping with interruptions is important for the nursing profession, quality of care and patient safety. Changing practice requires multidisciplinary cooperation accepting different agendas at personal, group and organisational levels. Nurses must understand the meaning and nature of different types of interruptions to develop coping strategies and maintain quality in care and patient safety in multidisciplinary teamwork. © 2018 John Wiley & Sons Ltd.
Current interruption in inductive storage systems with inertial current source
NASA Astrophysics Data System (ADS)
Vitkovitsky, I. M.; Conte, D.; Ford, R. D.; Lupton, W. H.
1980-03-01
Utilization of inertial current source inductive storage with high power output requires a switch with short opening time. This switch must operate as a circuit breaker, i.e., be capable to carry the current for a time period characteristic of inertial systems, such as homopolar generators. For reasonable efficiency, its opening time must be fast to minimize the energy dissipated in downstream fuse stages required for any additional pulse compression. A switch that satisfies these criteria, as well as other requirements such as that for high voltage operation associated with high power output, is an explosively driven switch consisting of large number of gaps arranged in series. The performance of this switch in limiting and/or interrupting currents produced by large generators has been studied. Single switch modules were designed and tested for limiting the commutating current output of 1 MW, 60 Hz, generator and 500 KJ capacitor banks. Current limiting and commutation were evaluated, using these sources, for currents ranging up to 0.4 MA. The explosive opening of the switch was found to provide an effective first stage for further pulse compression. It opens in tens of microseconds, commutates current at high efficiency ( = 905) recovers very rapidly over a wide range of operating conditions.
NASA Astrophysics Data System (ADS)
Cheng, Xian; Duan, Xiongying; Liao, Minfu; Huang, Zhihui; Luo, Yan; Zou, Jiyan
2013-08-01
Hybrid circuit breaker (HCB) technology based on a vacuum interrupter and a SF6 interrupter in series has become a new research direction because of the low-carbon requirements for high voltage switches. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage (TRV), while the SF6 interrupter can withstand the peak part of the voltage easily. An HCB can take advantage of the interrupters in the current interruption process. In this study, an HCB model based on the vacuum ion diffusion equations, ion density equation, and modified Cassie-Mayr arc equation is explored. A simulation platform is constructed by using a set of software called the alternative transient program (ATP). An HCB prototype is also designed, and the short circuit current is interrupted by the HCB under different action sequences of contacts. The voltage distribution of the HCB is analyzed through simulations and tests. The results demonstrate that if the vacuum interrupter withstands the initial TRV and interrupts the post-arc current first, then the recovery speed of the dielectric strength of the SF6 interrupter will be fast. The voltage distribution between two interrupters is determined by their post-arc resistance, which happens after current-zero, and subsequently, it is determined by the capacitive impedance after the post-arc current decays to zero.
The Effect of Interruption Duration and Demand on Resuming Suspended Goals
ERIC Educational Resources Information Center
Monk, Christopher A.; Trafton, J. Gregory; Boehm-Davis, Deborah A.
2008-01-01
The time to resume task goals after an interruption varied depending on the duration and cognitive demand of interruptions, as predicted by the memory for goals model (Altmann & Trafton, 2002). Three experiments using an interleaved tasks interruption paradigm showed that longer and more demanding interruptions led to longer resumption times in a…
ERIC Educational Resources Information Center
Dotson, Felecia
2017-01-01
The current study examines the effects that a coaching intervention has on the occurrences of scaffolding language techniques in a teacher's instructional delivery, in addition to the possible influences that a coaching intervention has on the teacher's ability to reflect on scaffolding language. More importantly, the study considers whether…
ERIC Educational Resources Information Center
Pridemore, William Alex; Trahan, Adam; Chamlin, Mitchell B.
2009-01-01
There is substantial evidence of detrimental psychological sequelae following disasters, including terrorist attacks. The effect of these events on extreme responses such as suicide, however, is unclear. We tested competing hypotheses about such effects by employing autoregressive integrated moving average techniques to model the impact of…
Opioid interruptions, pain, and withdrawal symptoms in nursing home residents.
Redding, Sarah E; Liu, Sophia; Hung, William W; Boockvar, Kenneth S
2014-11-01
Interruptions in opioid use have the potential to cause pain relapse and withdrawal symptoms. The objectives of this study were to observe patterns of opioid interruption during acute illness in nursing home residents and examine associations between interruptions and pain and withdrawal symptoms. Patients from 3 nursing homes in a metropolitan area who were prescribed opioids were assessed for symptoms of pain and withdrawal by researchers blinded to opioid dosage received, using the Brief Pain Inventory Scale and the Clinical Opioid Withdrawal Scale, respectively, during prespecified time periods. The prespecified time periods were 2 weeks after onset of acute illness (eg, urinary tract infection), and 2 weeks after hospital admission and nursing home readmission, if they occurred. Opioid dosing was recorded and a significant interruption was defined as a complete discontinuation or a reduction in dose of >50% for ≥1 day. The covariates age, sex, race, comorbid conditions, initial opioid dose, and initial pain level were recorded. Symptoms pre- and post-opioid interruptions were compared and contrasted with those in a group without opioid interruptions. Sixty-six patients receiving opioids were followed for a mean of 10.9 months and experienced a total of 104 acute illnesses. During 64 (62%) illnesses, patients experienced any reduction in opioid dosing, with a mean (SD) dose reduction of 63.9% (29.9%). During 39 (38%) illnesses, patients experienced a significant opioid interruption. In a multivariable model, residence at 1 of the 3 nursing homes was associated with a lower risk of interruption (odds ratio = 0.073; 95% CI, 0.009 to 0.597; P < 0.015). In patients with interruptions, there were statistically insignificant changes in mean (SD) pain score (difference -0.50 [2.66]; 95% CI, -3.16 to 2.16) and withdrawal score (difference -0.91 [3.12]; 95% CI, -4.03 to 2.21) after the interruption as compared with before interruption. However, when compared with patients without interruptions, patients with interruptions experienced larger increases in pain scores during the follow-up periods (difference 0.09 points per day; 95% CI, -0.01 to 0.019; P = 0.08). In particular, patients who received the highest quartile of opioid dose before interruption experienced increases in pain scores over time that were 0.22 points per day larger (95% CI, 0.02 to 0.41; P = 0.03) than those without interruption. Withdrawal scores were not associated with opioid interruption regardless of dose before interruption. Nursing home patients often experience interruptions in opioid dosing, which can be associated with worse pain, but not withdrawal symptoms, during acute illnesses. Clinicians should be aware of the potential risks and effects of opioid interruptions during acute illnesses in this patient group. Published by Elsevier Inc.
Lu, Sara A; Wickens, Christopher D; Prinet, Julie C; Hutchins, Shaun D; Sarter, Nadine; Sebok, Angelia
2013-08-01
The aim of this study was to integrate empirical data showing the effects of interrupting task modality on the performance of an ongoing visual-manual task and the interrupting task itself. The goal is to support interruption management and the design of multimodal interfaces. Multimodal interfaces have been proposed as a promising means to support interruption management.To ensure the effectiveness of this approach, their design needs to be based on an analysis of empirical data concerning the effectiveness of individual and redundant channels of information presentation. Three meta-analyses were conducted to contrast performance on an ongoing visual task and interrupting tasks as a function of interrupting task modality (auditory vs. tactile, auditory vs. visual, and single modality vs. redundant auditory-visual). In total, 68 studies were included and six moderator variables were considered. The main findings from the meta-analyses are that response times are faster for tactile interrupting tasks in case of low-urgency messages.Accuracy is higher with tactile interrupting tasks for low-complexity signals but higher with auditory interrupting tasks for high-complexity signals. Redundant auditory-visual combinations are preferable for communication tasks during high workload and with a small visual angle of separation. The three meta-analyses contribute to the knowledge base in multimodal information processing and design. They highlight the importance of moderator variables in predicting the effects of interruption task modality on ongoing and interrupting task performance. The findings from this research will help inform the design of multimodal interfaces in data-rich, event-driven domains.
Buchini, Sara; Quattrin, Rosanna
2012-04-01
To record the frequency of interruptions and their causes, to identify 'avoidable' interruptions and to build an improvement project to reduce 'avoidable' interruptions. In Italy each year 30,000-35,000 deaths per year are attributed to health-care system errors, of which 19% are caused by medication errors. The factors that contribute to drug management error also include interruptions and carelessness during treatment administration. A descriptive study design was used to record the frequency of interruptions and their causes and to identify 'avoidable' interruptions in an intensive rehabilitation ward in Northern Italy. A data collection grid was used to record the data over a 6-month period. A total of 3000 work hours were observed. During the study period 1170 interruptions were observed. The study identified 14 causes of interruption. The study shows that of the 14 cases of interruptions at least nine can be defined as 'avoidable'. An improvement project has been proposed to reduce unnecessary interruptions and distractions to avoid making errors. An additional useful step to reduce the incidence of treatment errors would be to implement the use of a single patient medication sheet for the recording of drug prescription, preparation and administration and also the incident reporting. © 2011 Blackwell Publishing Ltd.
Dealing with task interruptions in complex dynamic environments: are two heads better than one?
Tremblay, Sébastien; Vachon, François; Lafond, Daniel; Kramer, Chelsea
2012-02-01
This study examined whether teaming up mitigates individual vulnerability to task interruptions in complex dynamic situations. Omnipresent in everyday multitasking environments, task interruptions are usually detrimental to individual performance. This is particularly crucial in dynamic command and control (C2) safety-critical contexts because of the additional challenge imposed by the continually evolving situation during the interruption. We employed a firefighting microworld to simulate C2 in the context of supervisory control to examine the relative impact of interruptions on participants working in a functional dyad versus operators working alone. Although task interruption was detrimental to participants' efficacy of monitoring resources, the negative impact of interruption was reduced for those working in teams. Teaming up translated into faster resumption time, but only if both teammates were interrupted simultaneously. Interrupting only one team member was associated with increased postinterruption communications and slower resumption time. These findings suggest that in complex dynamic situations working in a small team confers more resistance to task interruption than working alone by virtue of the reduced individual workload typical of teamwork. The benefit of collaborative work seems nevertheless mediated by the coordination and communication overhead associated with teamwork. The present findings have practical implications for operators dealing with unexpected events such as task interruptions in C2 environments.
Continuous flow real-time PCR device using multi-channel fluorescence excitation and detection.
Hatch, Andrew C; Ray, Tathagata; Lintecum, Kelly; Youngbull, Cody
2014-02-07
High throughput automation is greatly enhanced using techniques that employ conveyor belt strategies with un-interrupted streams of flow. We have developed a 'conveyor belt' analog for high throughput real-time quantitative Polymerase Chain Reaction (qPCR) using droplet emulsion technology. We developed a low power, portable device that employs LED and fiber optic fluorescence excitation in conjunction with a continuous flow thermal cycler to achieve multi-channel fluorescence detection for real-time fluorescence measurements. Continuously streaming fluid plugs or droplets pass through tubing wrapped around a two-temperature zone thermal block with each wrap of tubing fluorescently coupled to a 64-channel multi-anode PMT. This work demonstrates real-time qPCR of 0.1-10 μL droplets or fluid plugs over a range of 7 orders of magnitude concentration from 1 × 10(1) to 1 × 10(7). The real-time qPCR analysis allows dynamic range quantification as high as 1 × 10(7) copies per 10 μL reaction, with PCR efficiencies within the range of 90-110% based on serial dilution assays and a limit of detection of 10 copies per rxn. The combined functionality of continuous flow, low power thermal cycling, high throughput sample processing, and real-time qPCR improves the rates at which biological or environmental samples can be continuously sampled and analyzed.
Vaisman, Alon; Wu, Robert C
2017-01-04
Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a 'crisis mode' climate. We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed 'crisis mode', defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The 'crisis mode' threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 - 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 - 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 - 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 - -0.703, p<0.05). Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when exceeding a maximal threshold over short periods of time.
The Effects of Career Interruptions on Young Men and Women.
ERIC Educational Resources Information Center
Shorten, Brett; Lewis, Donald E.
1991-01-01
Data from a sample of 5,837 Australians showed that (1) women had longer career interruptions; (2) regardless of number of interruptions, men had higher wages; (3) longer interruptions had a negative effect on reentry wages; and (4) 1985-88 growth in wages for males was enhanced by increased numbers and length of interruptions, with the opposite…
High Speed Solid State Circuit Breaker
NASA Technical Reports Server (NTRS)
Podlesak, Thomas F.
1993-01-01
The U.S. Army Research Laboratory, Fort Monmouth, NJ, has developed and is installing two 3.3 MW high speed solid state circuit breakers at the Army's Pulse Power Center. These circuit breakers will interrupt 4160V three phase power mains in no more than 300 microseconds, two orders of magnitude faster than conventional mechanical contact type circuit breakers. These circuit breakers utilize Gate Turnoff Thyristors (GTO's) and are currently utility type devices using air cooling in an air conditioned enclosure. Future refinements include liquid cooling, either water or two phase organic coolant, and more advanced semiconductors. Each of these refinements promises a more compact, more reliable unit.
PAs reduce rounding interruptions in the pediatric intensive care unit.
Hascall, Rebecca L; Perkins, R Serene; Kmiecik, Lauren; Gupta, Priya R; Shelak, Carolyn F; Demirel, Shaban; Buchholz, Mark T
2018-06-01
We investigated the proportion of encounters that were interrupted during family-centered rounds in the pediatric intensive care unit (PICU) to determine whether the use of a physician assistant (PA) significantly affected the proportion of interrupted encounters. We evaluated 2,657 rounding encounters in our 24-bed regional referral unit. The duration of each rounding encounter and total rounding duration were recorded. The presence or absence of a PA during each rounding encounter, the occurrence of an interruption, and other potential predictors of interruptions were recorded. The presence of a PA during PICU rounds was significantly associated (P < .001) with a 35.4% lower likelihood of an interruption. Family-centered rounds in the PICU are less likely to be interrupted when a PA is present. PAs help physicians and improve rounding efficiency by safely and effectively handling certain interruptions.
Li, Simon Y W; Magrabi, Farah; Coiera, Enrico
2012-01-01
To understand the complex effects of interruption in healthcare. As interruptions have been well studied in other domains, the authors undertook a systematic review of experimental studies in psychology and human-computer interaction to identify the task types and variables influencing interruption effects. 63 studies were identified from 812 articles retrieved by systematic searches. On the basis of interruption profiles for generic tasks, it was found that clinical tasks can be distinguished into three broad types: procedural, problem-solving, and decision-making. Twelve experimental variables that influence interruption effects were identified. Of these, six are the most important, based on the number of studies and because of their centrality to interruption effects, including working memory load, interruption position, similarity, modality, handling strategies, and practice effect. The variables are explained by three main theoretical frameworks: the activation-based goal memory model, prospective memory, and multiple resource theory. This review provides a useful starting point for a more comprehensive examination of interruptions potentially leading to an improved understanding about the impact of this phenomenon on patient safety and task efficiency. The authors provide some recommendations to counter interruption effects. The effects of interruption are the outcome of a complex set of variables and should not be considered as uniformly predictable or bad. The task types, variables, and theories should help us better to identify which clinical tasks and contexts are most susceptible and assist in the design of information systems and processes that are resilient to interruption.
Interruptions in emergency medicine: things are not always what they seem.
Walter, Scott R
2018-06-20
We have all felt the cognitive disjuncture of being interrupted during an important task. Most ED physicians will readily proffer the high frequency and/or burden of interruptions during their work, and of the many observational studies of interruptions in healthcare EDs do indeed have high interruption rates[2]. In experimental psychology, where many of these ideas originated, there is plenty of evidence that interruptions negatively affect performance. Interruptions have been associated with reduced performance on complex tasks[3,4], increased sequence errors[5], increased task completion time and augmented annoyance and anxiety[6]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
An architecture for intelligent task interruption
NASA Technical Reports Server (NTRS)
Sharma, D. D.; Narayan, Srini
1990-01-01
In the design of real time systems the capability for task interruption is often considered essential. The problem of task interruption in knowledge-based domains is examined. It is proposed that task interruption can be often avoided by using appropriate functional architectures and knowledge engineering principles. Situations for which task interruption is indispensable, a preliminary architecture based on priority hierarchies is described.
Schroers, Ginger
2018-06-26
The purpose of this review was to synthesize and summarize data gathered by direct observation of the characteristics of interruptions in the context of nursing medication administration in hospital settings. Interruptions are prevalent during the medication administration process performed by nurses in hospital settings and have been found to be associated with an increase in frequency and severity of nursing medication administration errors. In addition, interruptions decrease task efficiency, leading to longer medication administration completion times. Integrative review. The electronic databases Cumulative Index of Nursing and Allied Health Literature (CINAHL), PubMED, PsyARTICLES, and Google Scholar were searched using the terms "interruptions" AND "medication administration" AND "direct observation". Nine articles met the inclusion criteria. Interruptions are likely to occur at least once during nursing medication administration processes in hospital settings. This finding applies to medication administered to one patient, termed a medication pass, and medication administered to multiple patients, termed a mediation round. Interruptions are most commonly caused by another nurse, staff member, or are self-initiated, and last approximately one minute in length. A raised awareness among staff of the most common sources of interruptions may encourage changes that lead to a decrease in the occurrence of interruptions. In addition, nurse leaders can apply an understanding of the common characteristics of interruptions to guide research, policies, and educational methods aimed at interruption management strategies. The findings from this review can be used to guide the identification and development of targeted interventions and strategies that would have the most substantial impact to reduce and manage interruptions during medication administration. Interruption management strategies have the potential to lead to a decrease in medication errors and an increase in task efficiency. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
A new contribution to the classification of stressors affecting nursing professionals
Puerto, Jesús Cremades; Soler, Loreto Maciá; Montesinos, Maria José López; Marcos, Azucena Pedraz; Chorda, Víctor Manuel González
2017-01-01
Objective: to identify and classify the most important occupational stressors affecting nursing professionals in the medical units within a hospital. Method: quantitative-qualitative, descriptive and prospective study performed with Delphi technique in the medical units of a general university hospital, with a sample of 30 nursing professionals. Results: the stressors were work overload, frequent interruptions in the accomplishment of their tasks, night working, simultaneity of performing different tasks, not having enough time to give emotional support to the patient or lack of time for some patients who need it, among others. Conclusion: the most consensual stressors were ranked as work overload, frequent interruptions in the accomplishment of their tasks, night working and, finally, simultaneity of performing different tasks. These results can be used as a tool in the clinical management of hospital units, aiming to improve the quality of life of nursing professionals, organizational models and, in addition, continuous improvement in clinical treatment. PMID:28562702
The Value of Interrupted Time-Series Experiments for Community Intervention Research
Biglan, Anthony; Ary, Dennis; Wagenaar, Alexander C.
2015-01-01
Greater use of interrupted time-series experiments is advocated for community intervention research. Time-series designs enable the development of knowledge about the effects of community interventions and policies in circumstances in which randomized controlled trials are too expensive, premature, or simply impractical. The multiple baseline time-series design typically involves two or more communities that are repeatedly assessed, with the intervention introduced into one community at a time. It is particularly well suited to initial evaluations of community interventions and the refinement of those interventions. This paper describes the main features of multiple baseline designs and related repeated-measures time-series experiments, discusses the threats to internal validity in multiple baseline designs, and outlines techniques for statistical analyses of time-series data. Examples are given of the use of multiple baseline designs in evaluating community interventions and policy changes. PMID:11507793
Non-methylene-interrupted fatty acids with Δ5 unsaturation in Sargassum species.
Kim, Gwang-Woo; Itabashi, Yutaka
2012-01-01
Detailed fatty acid compositions of five species of the brown algae Sargassum (S. fulvellum, S. horneri, S. boreale, S. thunbergii, and S. yezoense) were determined using silver ion solid phase extraction, gas chromatography (GC), and GC-mass spectrometry (GC-MS) techniques. In addition to a high number of typical saturated and unsaturated fatty acids, the GC-MS spectra of the 4,4-dimethyloxazoline derivatives of fatty acids revealed the occurrence of small amounts of unusual non-methylene-interrupted (NMI) fatty acids with Δ5 unsaturation, namely, 5,9-eicosadienoic (5,9-20:2), 5,11,14-eicosatrienoic (5,11,14-20:3), and 5,11,14,17-eicosatetraenoic (5,11,14,17-20:4) acids. Of these three NMI acids, the 5,9-20:2 acid was found to be the most abundant (0.4%-2.3% of the total fatty acids) and was detected for the first time in algae.
Analysis of Smartphone Interruptions on Academic General Internal Medicine Wards
C.Wu, Robert
2017-01-01
Summary Introduction Hospital-based medical services are increasingly utilizing team-based pagers and smartphones to streamline communications. However, an unintended consequence may be higher volumes of interruptions potentially leading to medical error. There is likely a level at which interruptions are excessive and cause a ‘crisis mode’ climate. Methods We retrospectively collected phone, text messaging, and email interruptions directed to hospital-assigned smartphones on eight General Internal Medicine (GIM) teams at two tertiary care centres in Toronto, Ontario from April 2013 to September 2014. We also calculated the number of times these interruptions exceeded a pre-specified threshold per hour, termed ‘crisis mode’, defined as at least five interruptions in 30 minutes. We analyzed the correlation between interruptions and date, site, and patient volumes. Results A total of 187,049 interruptions were collected over an 18-month period. Daily weekday interruptions rose sharply in the morning, peaking between 11 AM to 12 PM and measuring 4.8 and 3.7 mean interruptions/hour at each site, respectively. Mean daily interruptions per team totaled 46.2 ± 3.6 at Site 1 and 39.2 ± 4.2 at Site 2. The ‘crisis mode’ threshold was exceeded, on average, 2.3 times/day per GIM team during weekdays. In a multivariable linear regression analysis, site (β6.43 CI95% 5.44 – 7.42, p<0.001), day of the week (with Friday having the most interruptions) (β0.481 CI95% 0.236 – 0.730, p<0.05) and patient census (β1.55 CI95% 1.42 – 1.67, p<0.05) were all predictive of daily interruption volume although there was a significant interaction effect between site and patient census (β-0.941 CI95% -1.18 – -0.703, p<0.05). Conclusion Interruptions were related to site-specific features, including volume, suggesting that future interventions should target the culture of individual hospitals. Excessive interruptions may have implications for patient safety especially when exceeding a maximal threshold over short periods of time. PMID:28066851
ERIC Educational Resources Information Center
O'Donoghue, Rob
2006-01-01
Memory-work is a feminist research methodology that is used by research collectives to study socialization within the dominant values that make up a particular culture. The power of memory-work lies with its potential to interrupt hegemonic ways of seeing and knowing the world. Consequently, it can open up possibilities for individual and social…
1980-03-01
striking influence of prior sodium intake on the pathogenesis of acute renal failure, raising the possibility that the renin - angiotensin system was...the product of the renin - angiotensin system , is the most powerful renal vasoconstrictor agent yet identified. These observations, viewed in the light of... angiotensin and, when they became available, to a detailed study of agents suitable for pharmacologic interruption of the renin - angiotensin system . We showed
New methods to detect particle velocity and mass flux in arc-heated ablation/erosion facilities
NASA Technical Reports Server (NTRS)
Brayton, D. B.; Bomar, B. W.; Seibel, B. L.; Elrod, P. D.
1980-01-01
Arc-heated flow facilities with injected particles are used to simulate the erosive and ablative/erosive environments encountered by spacecraft re-entry through fog, clouds, thermo-nuclear explosions, etc. Two newly developed particle diagnostic techniques used to calibrate these facilities are discussed. One technique measures particle velocity and is based on the detection of thermal radiation and/or chemiluminescence from the hot seed particles in a model ablation/erosion facility. The second technique measures a local particle rate, which is proportional to local particle mass flux, in a dust erosion facility by photodetecting and counting the interruptions of a focused laser beam by individual particles.
C-MOS array design techniques: SUMC multiprocessor system study
NASA Technical Reports Server (NTRS)
Clapp, W. A.; Helbig, W. A.; Merriam, A. S.
1972-01-01
The current capabilities of LSI techniques for speed and reliability, plus the possibilities of assembling large configurations of LSI logic and storage elements, have demanded the study of multiprocessors and multiprocessing techniques, problems, and potentialities. Evaluated are three previous systems studies for a space ultrareliable modular computer multiprocessing system, and a new multiprocessing system is proposed that is flexibly configured with up to four central processors, four 1/0 processors, and 16 main memory units, plus auxiliary memory and peripheral devices. This multiprocessor system features a multilevel interrupt, qualified S/360 compatibility for ground-based generation of programs, virtual memory management of a storage hierarchy through 1/0 processors, and multiport access to multiple and shared memory units.
2011-10-01
mémorandum technique fournit donc une description détaillée de l’approche des auteurs pour produire des calendriers des événements plus détaillés dans...SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT
Digenic Inheritance of PROKR2 and WDR11 Mutations in Pituitary Stalk Interruption Syndrome.
McCormack, Shana E; Li, Dong; Kim, Yeon Joo; Lee, Ji Young; Kim, Soo-Hyun; Rapaport, Robert; Levine, Michael A
2017-07-01
Pituitary stalk interruption syndrome (PSIS, ORPHA95496) is a congenital defect of the pituitary gland characterized by the triad of a very thin/interrupted pituitary stalk, an ectopic (or absent) posterior pituitary gland, and hypoplasia or aplasia of the anterior pituitary gland. Complex genetic patterns of inheritance of this disorder are increasingly recognized. The objective of this study was to identify a genetic cause of PSIS in an affected child. Whole exome sequencing (WES) was performed by using standard techniques, with prioritized genetic variants confirmed via Sanger sequencing. To investigate the effects of one candidate variant on mutant WDR11 function, Western blotting and coimmunofluorescence were used to assess binding capacity, and leptomycin B exposure along with immunofluorescence was used to assess nuclear localization. We describe a child who presented in infancy with combined pituitary hormone deficiencies and whose brain imaging demonstrated a small anterior pituitary, ectopic posterior pituitary, and a thin, interrupted stalk. WES demonstrated heterozygous missense mutations in two genes required for pituitary development, a known loss-of-function mutation in PROKR2 (c.253C>T;p.R85C) inherited from an unaffected mother, and a WDR11 (c.1306A>G;p.I436V) mutation inherited from an unaffected father. Mutant WDR11 loses its capacity to bind to its functional partner, EMX1, and to localize to the nucleus. WES in a child with PSIS and his unaffected family implicates a digenic mechanism of inheritance. In cases of hypopituitarism in which there is incomplete segregation of a monogenic genotype with the phenotype, the possibility that a second genetic locus is involved should be considered. Copyright © 2017 Endocrine Society
Method and apparatus for reading thermoluminescent phosphors
Braunlich, Peter F.; Tetzlaff, Wolfgang
1987-01-01
An apparatus and method for rapidly reading thermoluminescent phosphors to determine the amount of luminescent energy stored therein. The stored luminescent energy is interpreted as a measure of the total exposure of the thermoluminescent phosphor to ionizing radiation. The thermoluminescent phosphor reading apparatus uses a laser to generate a laser beam. The laser beam power level is monitored by a laser power detector and controlled to maintain the power level nearly constant. A shutter or other laser beam interrupting means is used to control exposure of the thermoluminescent phosphor to the laser beam. The laser beam can be equalized using an optical equalizer so that the laser beam has an approximately uniform power density across the beam. The heated thermoluminescent phosphor emits a visible or otherwise detectable luminescent emission which is measured as an indication of the radiation exposure of the thermoluminescent phosphors. Also disclosed are preferred signal processing and control circuits.
Resident perceptions of the impact of paging on intraoperative education.
Rose, Joel S; Waibel, Brett H; Schenarts, Paul J
2012-06-01
Our purpose was to evaluate the impact of paging on perceptions of intraoperative learning. Intraoperative logs of pager interruptions were kept by surgical residents at a university hospital over a 30-day period. The postgraduate year, number of pages, category of caller, reason for call, and level of urgency were recorded during each operation. At the conclusion of each operation, residents also completed a two-item survey with responses on a 5-point scale (1 = strongly disagree to 5 = strongly agree), querying if interruptions negatively impacted the intraoperative experience and if a message taken by a third party was effective in limiting interruptions. Logs were completed for 124 of 204 operations. Fifty-five per cent of operations were interrupted at least once with 49 per cent interrupted two to five times and 6 per cent were interrupted six or more times. Junior residents had 69 per cent of their operations interrupted compared with 39 per cent of senior residents (P = 0.001). Ninety-two per cent of pages were nonurgent. Residents did not perceive pager interruptions negatively impacted their educational experience (mean 2.3) but were neutral with respect if messages taken by a third party decreased interruptions (mean 3.8). Although our hypothesis was that pager interruptions were frequent and disrupt resident education, our data demonstrate the opposite.
Workflow interruptions and mental workload in hospital pediatricians: an observational study.
Weigl, Matthias; Müller, Andreas; Angerer, Peter; Hoffmann, Florian
2014-09-24
Pediatricians' workload is increasingly thought to affect pediatricians' quality of work life and patient safety. Workflow interruptions are a frequent stressor in clinical work, impeding clinicians' attention and contributing to clinical malpractice. We aimed to investigate prospective associations of workflow interruptions with multiple dimensions of mental workload in pediatricians during clinical day shifts. In an Academic Children's Hospital a prospective study of 28 full shift observations was conducted among pediatricians providing ward coverage. The prevalence of workflow interruptions was based on expert observation using a validated observation instrument. Concurrently, Pediatricians' workload ratings were assessed with three workload dimensions of the well-validated NASA-Task Load Index: mental demands, effort, and frustration. Observed pediatricians were, on average, disrupted 4.7 times per hour. Most frequent were interruptions by colleagues (30.2%), nursing staff (29.7%), and by telephone/beeper calls (16.3%). Interruption measures were correlated with two workload outcomes of interest: frequent workflow interruptions were related to less cognitive demands, but frequent interruptions were associated with increased frustration. With regard to single sources, interruptions by colleagues showed the strongest associations to workload. The findings provide insights into specific pathways between different types of interruptions and pediatricians' mental workload. These findings suggest further research and yield a number of work and organization re-design suggestions for pediatric care.
Huckels-Baumgart, Saskia; Niederberger, Milena; Manser, Tanja; Meier, Christoph R; Meyer-Massetti, Carla
2017-10-01
The aim was to evaluate the impact of staff training and wearing safety vests as a combined intervention on interruptions during medication preparation and double-checking. Interruptions and errors during the medication process are common and an important issue for patient safety in the hospital setting. We performed a pre- and post-intervention pilot-study using direct structured observation of 26 nurses preparing and double-checking 431 medication doses (225 pre-intervention and 206 post-intervention) for 36 patients (21 pre-intervention and 15 post-intervention). With staff training and the introduction of safety vests, the interruption rate during medication preparation was reduced from 36.8 to 28.3 interruptions per hour and during double-checking from 27.5 to 15 interruptions per hour. This pilot-study showed that the frequency of interruptions decreased during the critical tasks of medication preparation and double-checking after the introduction of staff training and wearing safety vests as part of a quality improvement process. Nursing management should acknowledge interruptions as an important factor potentially influencing medication safety. Unnecessary interruptions can be successfully reduced by considering human and system factors and increasing both staff and nursing managers' awareness of 'interruptive communication practices' and implementing physical barriers. This is the first pilot-study specifically evaluating the impact of staff training and wearing safety vests on the reduction of interruptions during medication preparation and double-checking. © 2017 John Wiley & Sons Ltd.
Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna
2017-01-01
Background Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. Methods We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Results Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Conclusions Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. PMID:27707869
The culture contributing to interruptions in the nursing work environment: An ethnography.
Hopkinson, Susan G; Wiegand, Debra L
2017-12-01
To understand the occurrence of interruptions within the culture of the medical nursing unit work environment. Interruptions may lead to errors in nursing work. Little is known about how the culture of the nursing work environment contributes to interruptions. A micro-focused ethnographic study was conducted. Data collection involved extensive observation of a nursing unit, 1:1 observations of nurses and follow-up interviews with the nurses. Data were analysed from unstructured field notes and interview transcripts. The definitions of interruption and culture guided coding, categorising and identification of themes. A framework was developed that describes the medical nursing unit as a complex culture full of unpredictable, nonlinear changes that affect the entire interconnected system, often in the form of an interruption. The cultural elements contributing to interruptions included (i) the value placed on excellence in patient care and meeting personal needs, (ii) the beliefs that the nurses had to do everything by themselves and that every phone call was important, (iii) the patterns of changing patients, patient transport and coordination of resources and (iv) the normative practices of communicating and adapting. Interruptions are an integral part of the culture of a medical nursing unit. Uniformly decreasing interruptions may disrupt current practices, such as communication to coordinate care, that are central to nursing work. In future research, the nursing work environment must be looked at through the lens of a complex system. Interventions to minimise the negative impact of interruptions must take into account the culture of the nursing as a complex adaptive system. Nurses should be educated on their own contribution to interruptions and issues addressed at a system level, rather than isolating the interruption as the central issue. © 2017 John Wiley & Sons Ltd.
Cavallari, Ilaria; Ruff, Christian T; Nordio, Francesco; Deenadayalu, Naveen; Shi, Minggao; Lanz, Hans; Rutman, Howard; Mercuri, Michele F; Antman, Elliott M; Braunwald, Eugene; Giugliano, Robert P
2018-04-15
Patients with atrial fibrillation (AF) who interrupt anticoagulation are at high risk of thromboembolism and death. Patients enrolled in the ENGAGE AF-TIMI 48 trial (randomized comparison of edoxaban vs. warfarin) who interrupted study anticoagulant for >3 days were identified. Clinical events (ischemic stroke/systemic embolism, major cardiac and cerebrovascular events [MACCE]) were analyzed from day 4 after interruption until day 34 or study drug resumption. During 2.8 years median follow-up, 13,311 (63%) patients interrupted study drug for >3 days. After excluding those who received open-label anticoagulation during the at-risk window, the population for analysis included 9148 patients. The rates of ischemic stroke/systemic embolism and MACCE post interruption were substantially greater than in patients who never interrupted (15.42 vs. 0.26 and 60.82 vs. 0.36 per 100 patient-years, respectively, p adj < .001). Patients who interrupted study drug for an adverse event (44.1% of the cohort), compared to those who interrupted for other reasons, had an increased risk of MACCE (HR adj 2.75; 95% CI 2.02-3.74, p < .0001), but similar rates of ischemic stroke/systemic embolism. Rates of clinical events after interruption of warfarin and edoxaban were similar. Interruption of study drug was frequent in patients with AF and was associated with a substantial risk of major cardiac and cerebrovascular events over the ensuing 30 days. This risk was particularly high in patients who interrupted as a result of an adverse event; these patients deserve close monitoring and resumption of anticoagulation as soon as it is safe to do so. Copyright © 2018 Elsevier B.V. All rights reserved.
Klemets, Joakim; Evjemo, Tor Erik
2014-09-01
Nurses' work in hospital departments is highly collaborative and includes communication with a variety of actors. To further support nurses' communications, wireless phones, on which nurses receive both nurse calls and ordinary phone calls, have been introduced. However, while they ensure high availability among the mobile nurses, these phones also contribute to an increased number of interruptions. This paper aims to discover whether all interruptions caused by the wireless phones are unwanted. Further, it investigates how nurses handle these interruptions in a hospital setting in order to construct a foundation for guidelines to use in designing these types of systems. Qualitative and ethnographically inspired fieldwork, including workshops with both ordinary and student nurses from a Norwegian hospital, was undertaken. Patients from two hospital departments were interviewed. Nurses struggle to handle interruptions caused by the wireless nurse call system. Deciding whether to abort an activity or not to respond to an interruption is regarded as stressful. The decision is further complicated by the complex nature of the interruptions. At the same time, patients anticipate that nurses are able to make these judgements with limited information. Nurses' work is highly collaborative, and nurses depend on one another to carry out their work and manage interruptions. The dual nature of the interruptions is complex, and whether an interruption is wanted or unwanted depends on many factors. Nurses manage interruptions mainly by making their own activities visible and monitoring colleagues' work. Therefore, nurses' awareness of colleagues' activities is a key factor in how they handle interruptions in the form of nurse calls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The geomagnetic blitz of September 1941
Love, Jeffrey J.; Coisson, Pierdavide
2016-01-01
Seventy-five years ago, on 18–19 September 1941, the Earth experienced a great magnetic storm, one of the most intense ever recorded. It arrived at a poignant moment in history, when radio and electrical technology was emerging as a central part of daily life and when much of the world was embroiled in World War II, which the United States had not yet officially entered.Auroras danced across the night sky as voltage surged in power grid lines. A radio blackout interrupted fan enjoyment of a baseball game, while another radio program was interrupted by private phone conversations. Citizens, already on edge, wondered if neon lights were some sort of antiaircraft signal. And far away in the North Atlantic, the illuminated night sky exposed an Allied convoy to German attack.These effects raised awareness within the scientific community and among the public of the societal significance of the effects that the Sun and outer space can have on the Earth—what we now call space weather.
Interruptions in a level one trauma center: a case study.
Brixey, Juliana J; Tang, Zhihua; Robinson, David J; Johnson, Craig W; Johnson, Todd R; Turley, James P; Patel, Vimla L; Zhang, Jiajie
2008-04-01
The emergency department has been characterized as interrupt-driven. Government agencies and patient safety organizations recognize that interruptions contribute to medical errors. The purpose of this study was to observe, record, and contextualize activities and interruptions experienced by physicians and Registered Nurses (RNs) working in a Level One Trauma Center. A case study that relied on an ethnographic study design using the shadowing method. A convenience sample of physicians and RNs, each with at least 6 months of experience in the Emergency Department (ED), were asked to participate. In these kinds of detailed qualitative investigations, it is quite common to have a small sample size. Ethical approval: Approval was obtained from institutional ethic committees prior to initiating the study. Community consent was obtained from the ED staff through in-service education. All observations were made in the trauma section of the ED of a tertiary teaching hospital. The hospital is situated in a major medical center in the Gulf Coast region of the United States of America (USA). Five attending ED physicians were observed for a total of 29h, 31min. Eight RNs were shadowed for a total of 40 h, 9min. Interruptions and activities were categorized using the Hybrid Method to Categorize Interruptions and Activities (HyMCIA). Registered Nurses received slightly more interruptions per hour than physicians. People, pagers, and telephones were identified as mediums through which interruptions were delivered. The physical environment was found to contribute to interruptions in workflow because of physical design and when supplies were not available. Physicians and RNs usually returned to the original, interrupted activity more often than leaving the activity unfinished. This research provides an enhanced understanding of interruptions in workflow in the ED, the identification of work constraints, and the need to develop interventions to manage interruptions. It is crucial that interruptions be delivered in such a way that there is minimal negative impact on performance. The significance and importance of the interruption must always be weighed against the negative impact that it has on smooth, efficient workflow.
Parisi, Amilcare; Ricci, Francesco; Gemini, Alessandro; Trastulli, Stefano; Cirocchi, Roberto; Palazzini, Giorgio; D’Andrea, Vito; Desiderio, Jacopo
2017-01-01
AIM To show outcomes of our series of patients that underwent a total gastrectomy with a robotic approach and highlight the technical details of a proposed solution for the reconstruction phase. METHODS Data of gastrectomies performed from May 2014 to October 2016, were extracted and analyzed. Basic characteristics of patients, surgical and clinical outcomes were reported. The technique for reconstruction (Parisi Technique) consists on a loop of bowel shifted up antecolic to directly perform the esophago-enteric anastomosis followed by a second loop, measured up to 40 cm starting from the esojejunostomy, fixed to the biliary limb to create an enteroenteric anastomosis. The continuity between the two anastomoses is interrupted just firing a linear stapler, so obtaining the Roux-en-Y by avoiding to interrupt the mesentery. RESULTS Fifty-five patients were considered in the present analysis. Estimated blood loss was 126.55 ± 73 mL, no conversions to open surgery occurred, R0 resections were obtained in all cases. Hospital stay was 5 (3-17) d, no anastomotic leakage occurred. Overall, a fast functional recovery was shown with a median of 3 (3-6) d in starting a solid diet. CONCLUSION Robotic surgery and the adoption of a tailored reconstruction technique have increased the feasibility and safety of a minimally invasive approach for total gastrectomy. The present series of patients shows its implementation in a western center with satisfying short-term outcomes. PMID:28694670
Tams, Stefan; Thatcher, Jason; Grover, Varun; Pak, Richard
2015-01-01
The ubiquity of instant messages and email notifications in contemporary work environments has opened a Pandora's Box. This box is filled with countless interruptions coming from laptops, smartphones, and other devices, all of which constantly call for employees' attention. In this interruption era, workplace stress is a pervasive problem. To examine this problem, the present study hypothesizes that the three-way interaction among the frequency with which interrupting stimuli appear, their salience, and employees' deficits in inhibiting attentional responses to them impacts mental workload perceptions, ultimately leading to stress. The study, further, probes a related form of self-efficacy as a potential suppressor of interruption-based stress. The study used a 2 (low vs. high frequency) × 2 (low vs. high salience) mixed model design. The 128 subjects completed a test of their inhibitory deficits and rated their mental workload perceptions and experiences of stress following a computer-based task. Inhibitory deficits and increased interruption salience can alter the perception of mental workload in contemporary work environments for the worse, but interruption self-efficacy can help offset any resulting interruption-based stress. This study extends the literatures on work interruptions as well as on stress and coping in the workplace.
Edelman, Robert R; Serhal, Ali; Pursnani, Amit; Pang, Jianing; Koktzoglou, Ioannis
2018-02-19
Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.
Artificial Intelligence Application in Power Generation Industry: Initial considerations
NASA Astrophysics Data System (ADS)
Ismail, Rahmat Izaizi B.; Ismail Alnaimi, Firas B.; AL-Qrimli, Haidar F.
2016-03-01
With increased competitiveness in power generation industries, more resources are directed in optimizing plant operation, including fault detection and diagnosis. One of the most powerful tools in faults detection and diagnosis is artificial intelligence (AI). Faults should be detected early so correct mitigation measures can be taken, whilst false alarms should be eschewed to avoid unnecessary interruption and downtime. For the last few decades there has been major interest towards intelligent condition monitoring system (ICMS) application in power plant especially with AI development particularly in artificial neural network (ANN). ANN is based on quite simple principles, but takes advantage of their mathematical nature, non-linear iteration to demonstrate powerful problem solving ability. With massive possibility and room for improvement in AI, the inspiration for researching them are apparent, and literally, hundreds of papers have been published, discussing the findings of hybrid AI for condition monitoring purposes. In this paper, the studies of ANN and genetic algorithm (GA) application will be presented.
NASA Astrophysics Data System (ADS)
Zhang, De-gan; Zhang, Xiao-dan
2012-11-01
With the growth of the amount of information manipulated by embedded application systems, which are embedded into devices and offer access to the devices on the internet, the requirements of saving the information systemically is necessary so as to fulfil access from the client and the local processing more efficiently. For supporting mobile applications, a design and implementation solution of embedded un-interruptible power supply (UPS) system (in brief, EUPSS) is brought forward for long-distance monitoring and controlling of UPS based on Web. The implementation of system is based on ATmega161, RTL8019AS and Arm chips with TCP/IP protocol suite for communication. In the embedded UPS system, an embedded file system is designed and implemented which saves the data and index information on a serial EEPROM chip in a structured way and communicates with a microcontroller unit through I2C bus. By embedding the file system into UPS system or other information appliances, users can access and manipulate local data on the web client side. Embedded file system on chips will play a major role in the growth of IP networking. Based on our experiment tests, the mobile users can easily monitor and control UPS in different places of long-distance. The performance of EUPSS has satisfied the requirements of all kinds of Web-based mobile applications.
Evaluation of Interruption Behavior by Naive Encoders.
ERIC Educational Resources Information Center
Coon, Christine A.; Schwanenflugel, Paula J.
1996-01-01
Determines the characteristics of interactions that influence judgments of interruption behavior in naive observers. Asks subjects to decide whether an example of an interruption was an interruption and then rate it in terms of how "good" or "bad" it was. Finds that naive observers use some of the same features described in…
[Economics, politics, and public health in Porfirian Mexico (1876-1910)].
Carrillo, Ana María
2002-01-01
The article examines the scientific, political, and economic elements that permitted the birth of modern public health in Mexico under the Porfirio Díaz administration (1876-1910). Firstly, a portion of Mexican physicians were open to the discoveries of microbiology, immunology, and epidemiology. Secondly, the State's growing concentration of power in public health matters ran parallel to its concentration of disciplinary political power and enabled this new knowledge to be placed at the service of collective health problem prevention. Lastly, both imperialism and the Porfirian elite needed to protect their business interests. The article evaluates public health achievements and limitations during the Porfirian period, abruptly interrupted by the revolution begun in 1910.
NASA Astrophysics Data System (ADS)
Chen, Chuan-Jie; Li, Shou-Zhe; Zhang, Jialiang; Liu, Dongping
2018-01-01
A pulse-modulated argon surface wave plasma generated at atmospheric pressure is characterized by means of temporally resolved optical emission spectroscopy (OES). The temporal evolution of the gas temperature, the electron temperature and density, the radiative species of atomic Ar, and the molecular band of OH(A) and N2(C) are investigated experimentally by altering the instantaneous power, pulse repetitive frequency, and duty ratio. We focused on the physical phenomena occurring at the onset of the time-on period and after the power interruption at the start of the time-off period. Meanwhile, the results are discussed qualitatively for an in-depth insight of its dynamic evolution.
Jenny, D B; Robert, G P; Fajadet, J C; Cassagneau, B G; Marco, J
1992-04-01
In this brief report we describe a case of successful multivessel PTCA with intracoronary stent implantation using a new large-lumen 7F catheter from the left brachial approach. The application of this technique should be considered for intravascular stent implantation when anticoagulation ideally should not be interrupted or in anatomical situations limiting femoral vascular access.
Assessing Impacts of Navigation Dredging on Atlantic Sturgeon (Acipenser oxyrinchus)
2014-11-01
fishes and insect larvae (Smith 1985, Dadswell 2006). Shallow water shoals located adjacent to both sides of the Federal navigation channel, provide a...incision was closed using sterile resorbitive suture material with four to five simple interrupted stitches. An iodine disinfectant was applied to the...1976). Assessment of techniques used to quantify salmon smolt entrainment by a hydraulic suction hopper dredge in the Fraser River estuary. Environment
NASA Astrophysics Data System (ADS)
Inada, Yuki; Kamiya, Tomoki; Matsuoka, Shigeyasu; Kumada, Akiko; Ikeda, Hisatoshi; Hidaka, Kunihiko
2018-01-01
Two-dimensional electron density imaging over free burning SF6 arcs and SF6 gas-blast arcs was conducted at current zero using highly sensitive Shack-Hartmann type laser wavefront sensors in order to experimentally characterise electron density distributions for the success and failure of arc interruption in the thermal reignition phase. The experimental results under an interruption probability of 50% showed that free burning SF6 arcs with axially asymmetric electron density profiles were interrupted with a success rate of 88%. On the other hand, the current interruption of SF6 gas-blast arcs was reproducibly achieved under locally reduced electron densities and the interruption success rate was 100%.
Interruption of the Tower of London Task: Support for a Goal-Activation Approach
ERIC Educational Resources Information Center
Hodgetts, Helen M.; Jones, Dylan M.
2006-01-01
Unexpected interruptions introduced during the execution phase of simple Tower of London problems incurred a time cost when the interrupted goal was retrieved, and this cost was exacerbated the longer the goal was suspended. Furthermore, time taken to retrieve goals was greater following a more complex interruption, indicating the processing…
Determining the Overall Impact of Interruptions during Online Testing
ERIC Educational Resources Information Center
Sinharay, Sandip; Wan, Ping; Whitaker, Mike; Kim, Dong-In; Zhang, Litong; Choi, Seung W.
2014-01-01
With an increase in the number of online tests, interruptions during testing due to unexpected technical issues seem unavoidable. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. There is a lack of research on this…
Sullivan, Jessica R.; Thibodeau, Linda M.; Assmann, Peter F.
2013-01-01
Previous studies have indicated that individuals with normal hearing (NH) experience a perceptual advantage for speech recognition in interrupted noise compared to continuous noise. In contrast, adults with hearing impairment (HI) and younger children with NH receive a minimal benefit. The objective of this investigation was to assess whether auditory training in interrupted noise would improve speech recognition in noise for children with HI and perhaps enhance their utilization of glimpsing skills. A partially-repeated measures design was used to evaluate the effectiveness of seven 1-h sessions of auditory training in interrupted and continuous noise. Speech recognition scores in interrupted and continuous noise were obtained from pre-, post-, and 3 months post-training from 24 children with moderate-to-severe hearing loss. Children who participated in auditory training in interrupted noise demonstrated a significantly greater improvement in speech recognition compared to those who trained in continuous noise. Those who trained in interrupted noise demonstrated similar improvements in both noise conditions while those who trained in continuous noise only showed modest improvements in the interrupted noise condition. This study presents direct evidence that auditory training in interrupted noise can be beneficial in improving speech recognition in noise for children with HI. PMID:23297921
Analysis of Generator Oscillation Characteristics Based on Multiple Synchronized Phasor Measurements
NASA Astrophysics Data System (ADS)
Hashiguchi, Takuhei; Yoshimoto, Masamichi; Mitani, Yasunori; Saeki, Osamu; Tsuji, Kiichiro
In recent years, there has been considerable interest in the on-line measurement, such as observation of power system dynamics and evaluation of machine parameters. On-line methods are particularly attractive since the machine’s service need not be interrupted and parameter estimation is performed by processing measurements obtained during the normal operation of the machine. Authors placed PMU (Phasor Measurement Unit) connected to 100V outlets in some Universities in the 60Hz power system and examine oscillation characteristics in power system. PMU is synchronized based on the global positioning system (GPS) and measured data are transmitted via Internet. This paper describes an application of PMU for generator oscillation analysis. The purpose of this paper is to show methods for processing phase difference and to estimate damping coeffcient and natural angular frequency from phase difference at steady state.
Electric power supply and demand for the contiguous United States, 1981 - 1990
NASA Astrophysics Data System (ADS)
1981-07-01
The outlook for electric power supply and demand in the United States decade 1981 to 1990 is reviewed from the perspective of reliability and adequacy of service. Electric power supply adequacy as projected for the nine Regional Reliability Council areas of the contiguous United States is reported as well as interruptible load data reported by the Councils. cogeneration is discussed. Each of the 27 electric regions (sub-areas of the nine Council areas) in the contiguous US are studied. A glossary of terms is given. Appendices describe the Council structure, and include a copy of the ERA-411 Manual, which contains all the items to which the Councils were asked to respond. The utilities with included data, the Staff Report, Estimated Electric Demand and Supply for Summer 1981, Contiguous United States dated May 1981 are included.
Radiation therapy interruption in a poor resource setting: causes and management..
Akinlade, B I; Folasire, A M; Elumelu-Kupoluyi, T N; Adenipekun, A A; Iyobosa, U B; Campbell, O B
2014-12-01
Treatment interruption is the failure to execute approved treatment plan of a patient. This adversely affects treatment outcomeif not properly managed. This retrospective study causes and management of radiation treatment interruptions during High Dose Rate Brachytherapy(HDRB) for carcinoma of the cervix in a teaching hospital in Nigeria. Five hundred patients with cervical carcinoma, who received HDRB, post external beam radiotherapy, between August, 2008 and July, 2013 were assessed. They were grouped into (A): those who experienced treatment interruption and (B): those who did not. Each patient was scheduled to receive three fractions of HDRB over 3 weeks. Those in groups A were assessed for the exact treatment fraction missed, the cause and duration of treatment interruption and the actions taken to compensate for non-execution of treatment. A total of 90 patients fall into group A and most (41) of them experienced interruptions in the third fraction of their treatment. The most frequent (44%) causes of treatment interruptions observed among them were patient-related. Record of compensation for treatment interruption was not found in patients' treatment folders. This action may be due to lack of functional procedures for managing treatment interruptions and insufficient follow-up of patients, who never came back for consideration for compensation. This study showed that radiation oncology centres need to review their policies for managing treatment interruptions and documentation. Also, the mechanism for patients' follow-up should be strengthened to a reasonable extent to achieve better radiotherapy care.
The Effect of Interruptions on Part 121 Air Carrier Operations
NASA Technical Reports Server (NTRS)
Damos, Diane L.
1998-01-01
The primary purpose of this study was to determine the relative priorities of various events and activities by examining the probability that a given activity was interrupted by a given event. The analysis will begin by providing frequency of interruption data by crew position (captain versus first officer) and event type. Any differences in the pattern of interruptions between the first officers and the captains will be explored and interpreted in terms of standard operating procedures. Subsequent data analyses will focus on comparing the frequency of interruptions for different types of activities and for the same activities under normal versus emergency conditions. Briefings and checklists will receive particular attention. The frequency with which specific activities are interrupted under multiple- versus single-task conditions also will be examined; because the majority of multiple-task data were obtained under laboratory conditions, LOFT-type tapes offer a unique opportunity to examine concurrent task performance under 'real-world' conditions. A second purpose of this study is to examine the effects of the interruptions on performance. More specifically, when possible, the time to resume specific activities will be compared to determine if pilots are slower to resume certain types of activities. Errors in resumption or failures to resume specific activities will be noted and any patterns in these errors will be identified. Again, particular attention will be given to the effects of interruptions on the completion of checklists and briefings. Other types of errors and missed events (i.e., the crew should have responded to the event but did not) will be examined. Any methodology using interruptions to examine task prioritization must be able to identify when an interruption has occurred and describe the ongoing activities that were interrupted. Both of these methodological problems are discussed In detail in the following section,
Bowden, Vanessa K; Visser, Troy A W; Loft, Shayne
2017-06-01
It is generally assumed that drivers speed intentionally because of factors such as frustration with the speed limit or general impatience. The current study examined whether speeding following an interruption could be better explained by unintentional prospective memory (PM) failure. In these situations, interrupting drivers may create a PM task, with speeding the result of drivers forgetting their newly encoded intention to travel at a lower speed after interruption. Across 3 simulated driving experiments, corrected or uncorrected speeding in recently reduced speed zones (from 70 km/h to 40 km/h) increased on average from 8% when uninterrupted to 33% when interrupted. Conversely, the probability that participants traveled under their new speed limit in recently increased speed zones (from 40 km/h to 70 km/h) increased from 1% when uninterrupted to 23% when interrupted. Consistent with a PM explanation, this indicates that interruptions lead to a general failure to follow changed speed limits, not just to increased speeding. Further testing a PM explanation, Experiments 2 and 3 manipulated variables expected to influence the probability of PM failures and subsequent speeding after interruptions. Experiment 2 showed that performing a cognitively demanding task during the interruption, when compared with unfilled interruptions, increased the probability of initially speeding from 1% to 11%, but that participants were able to correct (reduce) their speed. In Experiment 3, providing participants with 10s longer to encode the new speed limit before interruption decreased the probability of uncorrected speeding after an unfilled interruption from 30% to 20%. Theoretical implications and implications for road design interventions are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Medication administration and interruptions in nursing homes: A qualitative observational study.
Odberg, Kristian Ringsby; Hansen, Britt Saetre; Aase, Karina; Wangensteen, Sigrid
2018-03-01
To contribute in-depth knowledge of the characteristics of medication administration and interruptions in nursing homes. The following research questions guided the study: How can the medication administration process in nursing homes be described? How can interruptions during the medication administration process in nursing homes be characterized? Medication administration is a vital process across healthcare settings, and earlier research in nursing homes is sparse. The medication administration process is prone to interruptions that may lead to adverse drug events. On the other hand, interruptions may also have positive effects on patient safety. A qualitative observational study design was applied. Data were collected using partial participant observations. An inductive content analysis was performed. Factors that contributed to the observed complexity of medication administration in nursing homes were the high number of single tasks, varying degree of linearity, the variability of technological solutions, demands regarding documentation and staff's apparent freedom as to how and where to perform medication-related activities. Interruptions during medication administration are prevalent and can be characterised as passive (e.g., alarm and background noises), active (e.g., discussions) or technological interruptions (e.g., use of mobile applications). Most interruptions have negative outcomes, while some have positive outcomes. A process of normalisation has taken place whereby staff put up with second-rate technological solutions, noise and interruptions when they are performing medication-related tasks. Before seeking to minimise interruptions during the medication administration process, it is important to understand the interconnectivity of the elements using a systems approach. Staff and management need to be aware of the normalisation of interruptions. Knowledge of the complexity of medication administration may raise awareness and highlight the importance of maintaining and enhancing staff competence. © 2017 John Wiley & Sons Ltd.
Larcos, George; Prgomet, Mirela; Georgiou, Andrew; Westbrook, Johanna
2017-06-01
Errors by nuclear medicine technologists during the preparation of radiopharmaceuticals or at other times can cause patient harm and may reflect the impact of interruptions, busy work environments and deficient systems or processes. We aimed to: (a) characterise the rate and nature of interruptions technologists experience and (b) identify strategies that support safety. We performed 100 hours of observation of 11 technologists at a major public hospital and measured the proportions of time spent in eight categories of work tasks, location of task, interruption rate and type and multitasking (tasks conducted in parallel). We catalogued specific safety-oriented strategies used by technologists. Technologists completed 5227 tasks and experienced 569 interruptions (mean, 4.5 times per hour; 95% CI 4.1 to 4.9). The highest interruption rate occurred when technologists were in transit between rooms (10.3 per hour (95% CI 8.3 to 12.5)). Interruptions during radiopharmaceutical preparation occurred a mean of 4.4 times per hour (95% CI 3.3 to 5.6). Most (n=426) tasks were interrupted once only and all tasks were resumed after interruption. Multitasking occurred 16.6% of the time. At least some interruptions were initiated by other technologists to convey important information and/or to render assistance. Technologists employed a variety of verbal and non-verbal strategies in all work areas (notably in the hot-lab) to minimise the impact of interruptions and optimise the safe conduct of procedures. Although most were due to individual choices, some strategies reflected overt or subliminal departmental policy. Some interruptions appear beneficial. Technologists' self-initiated strategies to support safe work practices appear to be an important element in supporting a resilient work environment in nuclear medicine. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Westbrook, Johanna I; Li, Ling; Hooper, Tamara D; Raban, Magda Z; Middleton, Sandy; Lehnbom, Elin C
2017-09-01
To evaluate the effectiveness of a 'Do not interrupt' bundled intervention to reduce non-medication-related interruptions to nurses during medication administration. A parallel eight cluster randomised controlled study was conducted in a major teaching hospital in Adelaide, Australia. Four wards were randomised to the intervention which comprised wearing a vest when administering medications; strategies for diverting interruptions; clinician and patient education; and reminders. Control wards were blinded to the intervention. Structured direct observations of medication administration processes were conducted. The primary outcome was non-medication-related interruptions during individual medication dose administrations. The secondary outcomes were total interruption and multitasking rates. A survey of nurses' experiences was administered. Over 8 weeks and 364.7 hours, 227 nurses were observed administering 4781 medications. At baseline, nurses experienced 57 interruptions/100 administrations, 87.9% were unrelated to the medication task being observed. Intervention wards experienced a significant reduction in non-medication-related interruptions from 50/100 administrations (95% CI 45 to 55) to 34/100 (95% CI 30 to 38). Controlling for clustering, ward type and medication route showed a significant reduction of 15 non-medication-related interruptions/100 administrations compared with control wards. A total of 88 nurses (38.8%) completed the poststudy survey. Intervention ward nurses reported that vests were time consuming, cumbersome and hot. Only 48% indicated that they would support the intervention becoming hospital policy. Nurses experienced a high rate of interruptions. Few were related to the medication task, demonstrating considerable scope to reduce unnecessary interruptions. While the intervention was associated with a statistically significant decline in non-medication-related interruptions, the magnitude of this reduction and its likely impact on error rates should be considered, relative to the effectiveness of alternate interventions, associated costs, likely acceptability and long-term sustainability of such interventions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Traditions of research into interruptions in healthcare: A conceptual review.
McCurdie, Tara; Sanderson, Penelope; Aitken, Leanne M
2017-01-01
Researchers from diverse theoretical backgrounds have studied workplace interruptions in healthcare, leading to a complex and conflicting body of literature. Understanding pre-existing viewpoints may advance the field more effectively than attempts to remove bias from investigations. To identify research traditions that have motivated and guided interruptions research, and to note research questions posed, gaps in approach, and possible avenues for future research. A critical review was conducted of research on interruptions in healthcare. Two researchers identified core research communities based on the community's motivations, philosophical outlook, and methods. Among the characteristics used to categorise papers into research communities were the predominant motivation for studying interruptions, the research questions posed, and key contributions to the body of knowledge on interruptions in healthcare. In cases where a paper approached an equal number of characteristics from two traditions, it was placed in a blended research community. A total of 141 papers were identified and categorised; all papers identified were published from 1994 onwards. Four principal research communities emerged: epidemiology, quality improvement, cognitive systems engineering (CSE), and applied cognitive psychology. Blends and areas of mutual influence between the research communities were identified that combine the benefits of individual traditions, but there was a notable lack of blends incorporating quality improvement initiatives. The question most commonly posed by researchers across multiple communities was: what is the impact of interruptions? Impact was measured as a function of task time or risk in the epidemiology tradition, situation awareness in the CSE tradition, or resumption lag (time to resume an interrupted task) in the applied cognitive psychology tradition. No single question about interruptions in healthcare was shared by all four of the core communities. Much research on workplace interruptions in healthcare can be described in terms of fundamental values of four distinct research traditions and the communities that bring the values and methods: of those research traditions to their investigations. Blends between communities indicate that mutual influence has occurred as interruptions research has progressed. It is clear from this review that there is no single or privileged perspective to study interruptions. Instead, these findings suggest that researchers investigating interruptions in healthcare would benefit from being more aware of different perspectives from their own, especially when they consider workplace interventions to reduce interruptions. Copyright © 2016. Published by Elsevier Ltd.
Energy Management for Automatic Monitoring Stations in Arctic Regions
NASA Astrophysics Data System (ADS)
Pimentel, Demian
Automatic weather monitoring stations deployed in arctic regions are usually installed in hard to reach locations. Most of the time they run unsupervised and they face severe environmental conditions: very low temperatures, ice riming, etc. It is usual practice to use a local energy source to power the equipment. There are three main ways to achieve this: (1) a generator whose fuel has to be transported to the location at regular intervals (2) a battery and (3) an energy harvesting generator that exploits a local energy source. Hybrid systems are very common. Polar nights and long winters are typical of arctic regions. Solar radiation reaching the ground during this season is very low or non-existent, depending on the geographical location. Therefore, solar power generation is not very effective. One straightforward, but expensive and inefficient solution is the use of a large bank of batteries that is recharged during sunny months and discharged during the winter. The main purpose of the monitoring stations is to collect meteorological data at regular intervals; interruptions due to a lack of electrical energy can be prevented with the use of an energy management subsystem. Keeping a balance between incoming and outgoing energy flows, while assuring the continuous operation of the station, is the delicate task of energy management strategies. This doctoral thesis explores alternate power generation solutions and intelligent energy management techniques for equipment deployed in the arctic. For instance, harvesting energy from the wind to complement solar generation is studied. Nevertheless, harvested energy is a scarce resource and needs to be used efficiently. Genetic algorithms, fuzzy logic, and common sense are used to efficiently manage energy flows within a simulated arctic weather station.
Individual Differences in Working-Memory Capacity and Task Resumption Following Interruptions
ERIC Educational Resources Information Center
Foroughi, Cyrus K.; Werner, Nicole E.; McKendrick, Ryan; Cades, David M.; Boehm-Davis, Deborah A.
2016-01-01
Previous research has shown that there is a time cost (i.e., a resumption lag) associated with resuming a task following an interruption and that the longer the duration of the interruption, the greater the time cost (i.e., resumption lag increases as interruption duration increases). The memory-for-goals model (Altmann & Trafton, 2002)…
Assessing Individual-Level Impact of Interruptions during Online Testing
ERIC Educational Resources Information Center
Sinharay, Sandip; Wan, Ping; Choi, Seung W.; Kim, Dong-In
2015-01-01
With an increase in the number of online tests, the number of interruptions during testing due to unexpected technical issues seems to be on the rise. For example, interruptions occurred during several recent state tests. When interruptions occur, it is important to determine the extent of their impact on the examinees' scores. Researchers such as…
DC Interruption Characteristic on Vacuum Circuit Breaker
NASA Astrophysics Data System (ADS)
Odaka, Hiromi; Yamada, Masataka; Sakuma, Ryohei; Ding, Cuie; Kaneko, Eiji; Yanabu, Satoru
A high speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on a rate of change of the current (di/dt). As a fundamental research, we investigated the di/dt-dv/dt characteristics and the insulation recovery characteristic after interrupting the counter-pulse current for various contact materials of AgWC, CuW, and CuCr. The results revealed that the case where gap length is larger is better in a current interruption performance. Moreover, it was found that di/dt is not dependent on the insulation recovery characteristics, but the magnitude of interruption current influences greatly.
Initial Characterization of Optical Communications with Disruption-Tolerant Network Protocols
NASA Technical Reports Server (NTRS)
Schoolcraft, Joshua; Wilson, Keith
2011-01-01
Disruption-tolerant networks (DTNs) are groups of network assets connected with a suite of communication protocol technologies designed to mitigate the effects of link delay and disruption. Application of DTN protocols to diverse groups of network resources in multiple sub-networks results in an overlay network-of-networks with autonomous data routing capability. In space environments where delay or disruption is expected, performance of this type of architecture (such as an interplanetary internet) can increase with the inclusion of new communications mediums and techniques. Space-based optical communication links are therefore an excellent building block of space DTN architectures. When compared to traditional radio frequency (RF) communications, optical systems can provide extremely power-efficient and high bandwidth links bridging sub-networks. Because optical links are more susceptible to link disruption and experience the same light-speed delays as RF, optical-enabled DTN architectures can lessen potential drawbacks and maintain the benefits of autonomous optical communications over deep space distances. These environment-driven expectations - link delay and interruption, along with asymmetric data rates - are the purpose of the proof-of-concept experiment outlined herein. In recognizing the potential of these two technologies, we report an initial experiment and characterization of the performance of a DTN-enabled space optical link. The experiment design employs a point-to-point free-space optical link configured to have asymmetric bandwidth. This link connects two networked systems running a DTN protocol implementation designed and written at JPL for use on spacecraft, and further configured for higher bandwidth performance. Comparing baseline data transmission metrics with and without periodic optical link interruptions, the experiment confirmed the DTN protocols' ability to handle real-world unexpected link outages while maintaining capability of reliably delivering data at relatively high rates. Finally, performance characterizations from this data suggest performance optimizations to configuration and protocols for future optical-specific DTN space link scenarios.
NASA Astrophysics Data System (ADS)
Benetti, Micol; Pandolfi, Stefania; Lattanzi, Massimiliano; Martinelli, Matteo; Melchiorri, Alessandro
2013-01-01
Using the most recent data from the WMAP, ACT and SPT experiments, we update the constraints on models with oscillatory features in the primordial power spectrum of scalar perturbations. This kind of features can appear in models of inflation where slow-roll is interrupted, like multifield models. We also derive constraints for the case in which, in addition to cosmic microwave observations, we also consider the data on the spectrum of luminous red galaxies from the 7th SDSS catalog, and the SNIa Union Compilation 2 data. We have found that: (i) considering a model with features in the primordial power spectrum increases the agreement with data compared to the featureless “vanilla” ΛCDM model by Δχ2=6.7, representing an improvement with respect to the expected value Δχ2=3 for an equivalent model with three additional parameters; (ii) the uncertainty on the determination of the standard parameters is not degraded when features are included; (iii) the best fit for the features model locates the step in the primordial spectrum at a scale k≃0.005Mpc-1, corresponding to the scale where the outliers in the WMAP7 data at ℓ=22 and ℓ=40 are located.; (iv) a distinct, albeit less statistically significant peak is present in the likelihood at smaller scales, whose presence might be related to the WMAP7 preference for a negative value of the running of the scalar spectral index parameter; (v) the inclusion of the LRG-7 data does not change significantly the best fit model, but allows to better constrain the amplitude of the oscillations.
Deshazer, Garron; Prakash, Punit; Merck, Derek; Haemmerich, Dieter
2017-02-01
For computational models of microwave ablation (MWA), knowledge of the antenna design is necessary, but the proprietary design of clinical applicators is often unknown. We characterised the specific absorption rate (SAR) during MWA experimentally and compared to a multi-physics simulation. An infrared (IR) camera was used to measure SAR during MWA within a split ex vivo liver model. Perseon Medical's short-tip (ST) or long-tip (LT) MWA antenna were placed on top of a tissue sample (n = 6), and microwave power (15 W) was applied for 6 min, while intermittently interrupting power. Tissue surface temperature was recorded via IR camera (3.3 fps, 320 × 240 resolution). SAR was calculated intermittently based on temperature slope before and after power interruption. Temperature and SAR data were compared to simulation results. Experimentally measured SAR changed considerably once tissue temperatures exceeded 100 °C, contrary to simulation results. The ablation zone diameters were 1.28 cm and 1.30 ± 0.03 cm (transverse), and 2.10 cm and 2.66 ± -0.22 cm (axial), for simulation and experiment, respectively. The average difference in temperature between the simulation and experiment were 5.6 °C (ST) and 6.2 °C (LT). Dice coefficients for 1000 W/kg SAR iso-contour were 0.74 ± 0.01 (ST) and 0.77 (± 0.03) (LT), suggesting good agreement of SAR contours. We experimentally demonstrated changes in SAR during MWA ablation, which were not present in simulation, suggesting inaccuracies in dielectric properties. The measured SAR may be used in simplified computer simulations to predict tissue temperature when the antenna geometry is unknown.
Taljaard, Monica; McKenzie, Joanne E; Ramsay, Craig R; Grimshaw, Jeremy M
2014-06-19
An interrupted time series design is a powerful quasi-experimental approach for evaluating effects of interventions introduced at a specific point in time. To utilize the strength of this design, a modification to standard regression analysis, such as segmented regression, is required. In segmented regression analysis, the change in intercept and/or slope from pre- to post-intervention is estimated and used to test causal hypotheses about the intervention. We illustrate segmented regression using data from a previously published study that evaluated the effectiveness of a collaborative intervention to improve quality in pre-hospital ambulance care for acute myocardial infarction (AMI) and stroke. In the original analysis, a standard regression model was used with time as a continuous variable. We contrast the results from this standard regression analysis with those from segmented regression analysis. We discuss the limitations of the former and advantages of the latter, as well as the challenges of using segmented regression in analysing complex quality improvement interventions. Based on the estimated change in intercept and slope from pre- to post-intervention using segmented regression, we found insufficient evidence of a statistically significant effect on quality of care for stroke, although potential clinically important effects for AMI cannot be ruled out. Segmented regression analysis is the recommended approach for analysing data from an interrupted time series study. Several modifications to the basic segmented regression analysis approach are available to deal with challenges arising in the evaluation of complex quality improvement interventions.
Two color interferometric electron density measurement in an axially blown arc
NASA Astrophysics Data System (ADS)
Stoller, Patrick; Carstensen, Jan; Galletti, Bernardo; Doiron, Charles; Sokolov, Alexey; Salzmann, René; Simon, Sandor; Jabs, Philipp
2016-09-01
High voltage circuit breakers protect the power grid by interrupting the current in case of a short circuit. To do so an arc is ignited between two contacts as they separate; transonic gas flow is used to cool and ultimately extinguish the arc at a current-zero crossing of the alternating current. A detailed understanding of the arc interruption process is needed to improve circuit breaker design. The conductivity of the partially ionized gas remaining after the current-zero crossing, a key parameter in determining whether the arc will be interrupted or not, is a function of the electron density. The electron density, in turn, is a function of the detailed dynamics of the arc cooling process, which does not necessarily occur under local thermodynamic equilibrium (LTE) conditions. In this work, we measure the spatially resolved line-integrated index of refraction in a near-current-zero arc stabilized in an axial flow of synthetic air with two nanosecond pulsed lasers at wavelengths of 532 nm and 671 nm. Generating a stable, cylindrically symmetric arc enables us to determine the three-dimensional index of refraction distribution using Abel inversion. Due to the wavelength dependence of the component of the index of refraction related to the free electrons, the information at two different wavelengths can be used to determine the electron density. This information allows us to determine how important it is to take into account non-equilibrium effects for accurate modeling of the physics of decaying arcs.
Superconducting Magnetic Energy Storage (SMES) Program
NASA Astrophysics Data System (ADS)
Rogers, J. D.
1985-05-01
The 30 MJ, 10 MW superconducting magnetic energy storage (SMES) system was devised to interact in the Western US Power System as an alternate means to damp unstable oscillations at 0.35 Hz on the Pacific HVAC Interites. The operating limits of the 30 MJ SMES unit were established, and different means of controlling real and reactive power were tested. The unit can follow a sinusoidal power demand signal with an amplitude of up to 8.6 MW with the converter working in a 12 pulse mode. When the converter operates in the constant VAR mode, a time varying real power demand signal of up to 5 MW can be met. It was shown that the Pacific ac Interite has current and reactive power variations of the same frequency as the modulating frequency of the SMES device. The reliability of the SMES subsystems with a narrow band noise input was assessed. Parameters of the ac power system were determined. Converter short circuit tests, load tests under various control conditions, dc breaker tests for coil current interruption, and converter failure mode tests were conducted. The experimental operation of the SMES system is concluded.
Optimizing the Energy and Throughput of a Water-Quality Monitoring System.
Olatinwo, Segun O; Joubert, Trudi-H
2018-04-13
This work presents a new approach to the maximization of energy and throughput in a wireless sensor network (WSN), with the intention of applying the approach to water-quality monitoring. Water-quality monitoring using WSN technology has become an interesting research area. Energy scarcity is a critical issue that plagues the widespread deployment of WSN systems. Different power supplies, harvesting energy from sustainable sources, have been explored. However, when energy-efficient models are not put in place, energy harvesting based WSN systems may experience an unstable energy supply, resulting in an interruption in communication, and low system throughput. To alleviate these problems, this paper presents the joint maximization of the energy harvested by sensor nodes and their information-transmission rate using a sum-throughput technique. A wireless information and power transfer (WIPT) method is considered by harvesting energy from dedicated radio frequency sources. Due to the doubly near-far condition that confronts WIPT systems, a new WIPT system is proposed to improve the fairness of resource utilization in the network. Numerical simulation results are presented to validate the mathematical formulations for the optimization problem, which maximize the energy harvested and the overall throughput rate. Defining the performance metrics of achievable throughput and fairness in resource sharing, the proposed WIPT system outperforms an existing state-of-the-art WIPT system, with the comparison based on numerical simulations of both systems. The improved energy efficiency of the proposed WIPT system contributes to addressing the problem of energy scarcity.
Sen, Alper; Gümüsay, M Umit; Kavas, Aktül; Bulucu, Umut
2008-09-25
Wireless communication networks offer subscribers the possibilities of free mobility and access to information anywhere at any time. Therefore, electromagnetic coverage calculations are important for wireless mobile communication systems, especially in Wireless Local Area Networks (WLANs). Before any propagation computation is performed, modeling of indoor radio wave propagation needs accurate geographical information in order to avoid the interruption of data transmissions. Geographic Information Systems (GIS) and spatial interpolation techniques are very efficient for performing indoor radio wave propagation modeling. This paper describes the spatial interpolation of electromagnetic field measurements using a feed-forward back-propagation neural network programmed as a tool in GIS. The accuracy of Artificial Neural Networks (ANN) and geostatistical Kriging were compared by adjusting procedures. The feedforward back-propagation ANN provides adequate accuracy for spatial interpolation, but the predictions of Kriging interpolation are more accurate than the selected ANN. The proposed GIS ensures indoor radio wave propagation model and electromagnetic coverage, the number, position and transmitter power of access points and electromagnetic radiation level. Pollution analysis in a given propagation environment was done and it was demonstrated that WLAN (2.4 GHz) electromagnetic coverage does not lead to any electromagnetic pollution due to the low power levels used. Example interpolated electromagnetic field values for WLAN system in a building of Yildiz Technical University, Turkey, were generated using the selected network architectures to illustrate the results with an ANN.
Şen, Alper; Gümüşay, M. Ümit; Kavas, Aktül; Bulucu, Umut
2008-01-01
Wireless communication networks offer subscribers the possibilities of free mobility and access to information anywhere at any time. Therefore, electromagnetic coverage calculations are important for wireless mobile communication systems, especially in Wireless Local Area Networks (WLANs). Before any propagation computation is performed, modeling of indoor radio wave propagation needs accurate geographical information in order to avoid the interruption of data transmissions. Geographic Information Systems (GIS) and spatial interpolation techniques are very efficient for performing indoor radio wave propagation modeling. This paper describes the spatial interpolation of electromagnetic field measurements using a feed-forward back-propagation neural network programmed as a tool in GIS. The accuracy of Artificial Neural Networks (ANN) and geostatistical Kriging were compared by adjusting procedures. The feedforward back-propagation ANN provides adequate accuracy for spatial interpolation, but the predictions of Kriging interpolation are more accurate than the selected ANN. The proposed GIS ensures indoor radio wave propagation model and electromagnetic coverage, the number, position and transmitter power of access points and electromagnetic radiation level. Pollution analysis in a given propagation environment was done and it was demonstrated that WLAN (2.4 GHz) electromagnetic coverage does not lead to any electromagnetic pollution due to the low power levels used. Example interpolated electromagnetic field values for WLAN system in a building of Yildiz Technical University, Turkey, were generated using the selected network architectures to illustrate the results with an ANN. PMID:27873854
Optimizing the Energy and Throughput of a Water-Quality Monitoring System
Olatinwo, Segun O.
2018-01-01
This work presents a new approach to the maximization of energy and throughput in a wireless sensor network (WSN), with the intention of applying the approach to water-quality monitoring. Water-quality monitoring using WSN technology has become an interesting research area. Energy scarcity is a critical issue that plagues the widespread deployment of WSN systems. Different power supplies, harvesting energy from sustainable sources, have been explored. However, when energy-efficient models are not put in place, energy harvesting based WSN systems may experience an unstable energy supply, resulting in an interruption in communication, and low system throughput. To alleviate these problems, this paper presents the joint maximization of the energy harvested by sensor nodes and their information-transmission rate using a sum-throughput technique. A wireless information and power transfer (WIPT) method is considered by harvesting energy from dedicated radio frequency sources. Due to the doubly near–far condition that confronts WIPT systems, a new WIPT system is proposed to improve the fairness of resource utilization in the network. Numerical simulation results are presented to validate the mathematical formulations for the optimization problem, which maximize the energy harvested and the overall throughput rate. Defining the performance metrics of achievable throughput and fairness in resource sharing, the proposed WIPT system outperforms an existing state-of-the-art WIPT system, with the comparison based on numerical simulations of both systems. The improved energy efficiency of the proposed WIPT system contributes to addressing the problem of energy scarcity. PMID:29652866
Toledo, Eran; Collins, Keith A; Williams, Ursula; Lammertin, Georgeanne; Bolotin, Gil; Raman, Jai; Lang, Roberto M; Mor-Avi, Victor
2005-12-01
Echocardiographic quantification of myocardial perfusion is based on analysis of contrast replenishment after destructive high-energy ultrasound impulses (flash-echo). This technique is limited by nonuniform microbubble destruction and the dependency on exponential fitting of a small number of noisy time points. We hypothesized that brief interruptions of contrast infusion (ICI) would result in uniform contrast clearance followed by slow replenishment and, thus, would allow analysis from multiple data points without exponential fitting. Electrocardiographic-triggered images were acquired in 14 isolated rabbit hearts (Langendorff) at 3 levels of coronary flow (baseline, 50%, and 15%) during contrast infusion (Definity) with flash-echo and with a 20-second infusion interruption. Myocardial videointensity was measured over time from flash-echo sequences, from which characteristic constant beta was calculated using an exponential fit. Peak contrast inflow rate was calculated from ICI data using analysis of local time derivatives. Computer simulations were used to investigate the effects of noise on the accuracy of peak contrast inflow rate and beta calculations. ICI resulted in uniform contrast clearance and baseline replenishment times of 15 to 25 cardiac cycles. Calculated peak contrast inflow rate followed the changes in coronary flow in all hearts at both levels of reduced flow (P < .05) and had a low intermeasurement variability of 7 +/- 6%. With flash-echo, contrast clearance was less uniform and baseline replenishment times were only 4 to 6 cardiac cycles. beta Decreased significantly only at 15% flow, and had intermeasurement variability of 42 +/- 33%. Computer simulations showed that measurement errors in both perfusion indices increased with noise, but beta had larger errors at higher rates of contrast inflow. ICI provides the basis for accurate and reproducible quantification of myocardial perfusion using fast and robust numeric analysis, and may constitute an alternative to the currently used techniques.
Muirhead, R; Drinkwater, K; O'Cathail, S M; Adams, R; Glynne-Jones, R; Harrison, M; Hawkins, M A; Sebag-Montefiore, D; Gilbert, D C
2017-03-01
UK guidance was recently developed for the treatment of anal cancer using intensity-modulated radiotherapy (IMRT). We audited the current use of radiotherapy in UK cancer centres for the treatment of anal cancer against such guidance. We describe the acute toxicity of IMRT in comparison with patient population in the audit treated with two-phase conformal radiotherapy and the previous published data from two-phase conformal radiotherapy, in the UK ACT2 trial. A Royal College of Radiologists' prospective national audit of patients treated with radiotherapy in UK cancer centres was carried out over a 6 month period between February and July 2015. Two hundred and forty-two cases were received from 40/56 cancer centres (71%). In total, 231 (95%) underwent full dose radiotherapy with prophylactic nodal irradiation. Of these, 180 (78%) received IMRT or equivalent, 52 (22%) two-phase conformal (ACT2) technique. The number of interruptions in radiotherapy treatment in the ACT2 trial was 15%. Interruptions were noted in 7% (95% confidence interval 0-14%) of courses receiving two-phase conformal and 4% (95% confidence interval 1-7%) of those receiving IMRT. The percentage of patients completing the planned radiotherapy dose, irrelevant of gaps, was 90% (95% confidence interval 82-98%) and 96% (95% confidence interval 93-99%), in two-phase conformal and IMRT respectively. The toxicity reported in the ACT2 trial, in patients receiving two-phase conformal in the audit and in patients receiving IMRT in the audit was: any toxic effect 71%, 54%, 48%, non-haematological 62%, 49%, 40% and haematological 26%, 13%, 18%, respectively. IMRT implementation for anal cancer is well underway in the UK with most patients receiving IMRT delivery, although its usage is not yet universal. This audit confirms that IMRT results in reduced acute toxicity and minimised treatment interruptions in comparison with previous two-phase conformal techniques. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Ten major studies are included in this report; a separate abstract was prepared for each. In addition, there are 4 appendices related to reliability, namely: (A) Load and Generation Uncertainty, by Norton Savage, DOE; (B) Comparison of Service-Interruption Cost Studies, by Dr. Gay Lamb, DOE; (C) Impact of Large-Scale Fuel-Supply Disruptions on Regional Electric-Power Reliability, by Anthony J. Como and Mark Gielecki, DOE; and (D) Reliability Effects of the 1980 Florida Conservation Act, by William E. Scott and Thomas R. Hitz, Jr., DOE. (LCL)
Data Center Energy Efficiency Measurement Assessment Kit Guide and Specification
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-10-26
A portable and temporary wireless mesh assessment kit can be used to speed up and reduce the costs of a data center energy use assessment and overcome the issues with respect to shutdowns. The assessment kit is comprised of temperature, relative humidity, and pressure sensors. Also included are power meters that can be installed on computer room air conditioners (CRACs) without intrusive interruption of data center operations. The assessment kit produces data required for a detailed energy assessment of the data center.
The Chronic Detrimental Impact of Interruptions in a Simulated Submarine Track Management Task.
Loft, Shayne; Sadler, Andreas; Braithwaite, Janelle; Huf, Samuel
2015-12-01
The objective of this article is to examine the extent to which interruptions negatively impact situation awareness and long-term performance in a submarine track management task where pre- and postinterruption display scenes remained essentially identical. Interruptions in command and control task environments can degrade performance well beyond the first postinterruption action typically measured for sequential static tasks, because individuals need to recover their situation awareness for multiple unfolding display events. Participants in the current study returned to an unchanged display scene following interruption and therefore could be more immune to such long-term performance deficits. The task required participants to monitor a display to detect contact heading changes and to make enemy engagement decisions. Situation awareness (Situation Present Assessment Method) and subjective workload (NASA-Task Load Index) were measured. The interruption replaced the display for 20 s with a blank screen, during which participants completed a classification task. Situation awareness after returning from interruption was degraded. Participants were slower to make correct engagement decisions and slower and less accurate in detecting heading changes, despite these task decisions being made at least 40 s following the interruption. Interruptions negatively impacted situation awareness and long-term performance because participants needed to redetermine the location and spatial relationship between the displayed contacts when returning from interruption, either because their situation awareness for the preinterruption scene decayed or because they did not encode the preinterruption scene. Interruption in work contexts such as submarines is unavoidable, and further understanding of how operators are affected is required to improve work design and training. © 2015, Human Factors and Ergonomics Society.
Landrian, Ivette; McFarland, Karen N; Liu, Jilin; Mulligan, Connie J; Rasmussen, Astrid; Ashizawa, Tetsuo
2017-01-01
Spinocerebellar ataxia type 10 (SCA10), an autosomal dominant cerebellar ataxia disorder, is caused by a non-coding ATTCT microsatellite repeat expansion in the ataxin 10 gene. In a subset of SCA10 families, the 5'-end of the repeat expansion contains a complex sequence of penta- and heptanucleotide interruption motifs which is followed by a pure tract of tandem ATCCT repeats of unknown length at its 3'-end. Intriguingly, expansions that carry these interruption motifs correlate with an epileptic seizure phenotype and are unstable despite the theory that interruptions are expected to stabilize expanded repeats. To examine the apparent contradiction of unstable, interruption-positive SCA10 expansion alleles and to determine whether the instability originates outside of the interrupted region, we sequenced approximately 1 kb of the 5'-end of SCA10 expansions using the ATCCT-PCR product in individuals across multiple generations from four SCA10 families. We found that the greatest instability within this region occurred in paternal transmissions of the allele in stretches of pure ATTCT motifs while the intervening interrupted sequences were stable. Overall, the ATCCT interruption changes by only one to three repeat units and therefore cannot account for the instability across the length of the disease allele. We conclude that the AT-rich interruptions locally stabilize the SCA10 expansion at the 5'-end but do not completely abolish instability across the entire span of the expansion. In addition, analysis of the interruption alleles across these families support a parsimonious single origin of the mutation with a shared distant ancestor.
ERIC Educational Resources Information Center
Mansi, Gary R.
2011-01-01
The modern workplace environment is filled with interruptions due to the necessity of coworkers to communicate with each other. Studies have revealed that interruptions can disrupt the ability of a knowledge worker to concentrate on a task, which can impact task performance (TP). Communication interruptions are due, in part, to the unavoidable…
Joint Services Electronics Program.
1981-09-30
devices and a structure in which an interrupted superconduc- tive film strip lies on a highly doped silicon surface. We have also developed a strong...Slusher, and H. Sturge, reported at 2nd Int’l Conf. on Submillimeter Waves and Their Applications, San Juan , P.R., December 1967. (12) T. DeGraauw, H... lies in the noncommutative property of matrix multiplication. However, we believe that techniques can be developed to deal with special classes of non
Lin, Yun; Wang, Chao; Wang, Jiaxing; Dou, Zheng
2016-10-12
Cognitive radio sensor networks are one of the kinds of application where cognitive techniques can be adopted and have many potential applications, challenges and future research trends. According to the research surveys, dynamic spectrum access is an important and necessary technology for future cognitive sensor networks. Traditional methods of dynamic spectrum access are based on spectrum holes and they have some drawbacks, such as low accessibility and high interruptibility, which negatively affect the transmission performance of the sensor networks. To address this problem, in this paper a new initialization mechanism is proposed to establish a communication link and set up a sensor network without adopting spectrum holes to convey control information. Specifically, firstly a transmission channel model for analyzing the maximum accessible capacity for three different polices in a fading environment is discussed. Secondly, a hybrid spectrum access algorithm based on a reinforcement learning model is proposed for the power allocation problem of both the transmission channel and the control channel. Finally, extensive simulations have been conducted and simulation results show that this new algorithm provides a significant improvement in terms of the tradeoff between the control channel reliability and the efficiency of the transmission channel.
Lin, Yun; Wang, Chao; Wang, Jiaxing; Dou, Zheng
2016-01-01
Cognitive radio sensor networks are one of the kinds of application where cognitive techniques can be adopted and have many potential applications, challenges and future research trends. According to the research surveys, dynamic spectrum access is an important and necessary technology for future cognitive sensor networks. Traditional methods of dynamic spectrum access are based on spectrum holes and they have some drawbacks, such as low accessibility and high interruptibility, which negatively affect the transmission performance of the sensor networks. To address this problem, in this paper a new initialization mechanism is proposed to establish a communication link and set up a sensor network without adopting spectrum holes to convey control information. Specifically, firstly a transmission channel model for analyzing the maximum accessible capacity for three different polices in a fading environment is discussed. Secondly, a hybrid spectrum access algorithm based on a reinforcement learning model is proposed for the power allocation problem of both the transmission channel and the control channel. Finally, extensive simulations have been conducted and simulation results show that this new algorithm provides a significant improvement in terms of the tradeoff between the control channel reliability and the efficiency of the transmission channel. PMID:27754316
Crusco, Salvatore; Jackson, Tiffany; Advincula, Arnold
2014-01-01
Robot-assisted laparoscopic surgery is often taught with the surgical mentor at the surgeon console and the trainee at the patient's bedside. The da Vinci dual console (Intuitive Surgical, Sunnyvale, California) allows a surgical mentor to teach with both the mentor and the trainee working at a surgeon console simultaneously. The purpose of this study is to evaluate the effectiveness of the dual console versus the single console for teaching medical students robotic tasks. Forty novice medical students were randomized to either the da Vinci single-console or dual-console group and were taught 4 knot-tying techniques by a surgical mentor. The students were timed while performing the tasks. No statistically significant differences in mean task times were observed between the single- and dual-console groups: interrupted stitch with a 2-handed knot (300 seconds for single vs 294 seconds for dual, P=.59), interrupted stitch with a 1-handed knot (198 seconds for single vs 212 seconds for dual, P=.88), figure-of-8 stitch with a 2-handed knot (261 seconds for single vs 219 seconds for dual, P=.20), and figure-of-8 stitch with a 1-handed knot (200 seconds for single vs 199 seconds for dual, P=.53). No significant difference was observed in performance time when teaching knot-tying techniques to medical students using the da Vinci dual console compared with the single console. More research needs to be performed on the utility of the da Vinci dual console in surgical training.
Jackson, Tiffany; Advincula, Arnold
2014-01-01
Background and Objectives: Robot-assisted laparoscopic surgery is often taught with the surgical mentor at the surgeon console and the trainee at the patient's bedside. The da Vinci dual console (Intuitive Surgical, Sunnyvale, California) allows a surgical mentor to teach with both the mentor and the trainee working at a surgeon console simultaneously. The purpose of this study is to evaluate the effectiveness of the dual console versus the single console for teaching medical students robotic tasks. Methods: Forty novice medical students were randomized to either the da Vinci single-console or dual-console group and were taught 4 knot-tying techniques by a surgical mentor. The students were timed while performing the tasks. Results: No statistically significant differences in mean task times were observed between the single- and dual-console groups: interrupted stitch with a 2-handed knot (300 seconds for single vs 294 seconds for dual, P = .59), interrupted stitch with a 1-handed knot (198 seconds for single vs 212 seconds for dual, P = .88), figure-of-8 stitch with a 2-handed knot (261 seconds for single vs 219 seconds for dual, P = .20), and figure-of-8 stitch with a 1-handed knot (200 seconds for single vs 199 seconds for dual, P = .53). Conclusion: No significant difference was observed in performance time when teaching knot-tying techniques to medical students using the da Vinci dual console compared with the single console. More research needs to be performed on the utility of the da Vinci dual console in surgical training. PMID:25392618
Kerr, Jacqueline; Crist, Katie; Vital, Daniela G; Dillon, Lindsay; Aden, Sabrina A; Trivedi, Minaxi; Castellanos, Luis R; Godbole, Suneeta; Li, Hongying; Allison, Matthew A; Khemlina, Galina L; Takemoto, Michelle L; Schenk, Simon; Sallis, James F; Grace, Megan; Dunstan, David W; Natarajan, Loki; LaCroix, Andrea Z; Sears, Dorothy D
2017-01-01
Prolonged sitting is associated with cardiometabolic and vascular disease. Despite emerging evidence regarding the acute health benefits of interrupting prolonged sitting time, the effectiveness of different modalities in older adults (who sit the most) is unclear. In preparation for a future randomized controlled trial, we enrolled 10 sedentary, overweight or obese, postmenopausal women (mean age 66 years ±9; mean body mass index 30.6 kg/m2 ±4.2) in a 4-condition, 4-period crossover feasibility pilot study in San Diego to test 3 different sitting interruption modalities designed to improve glucoregulatory and vascular outcomes compared to a prolonged sitting control condition. The interruption modalities included: a) 2 minutes standing every 20 minutes; b) 2 minutes walking every hour; and c) 10 minutes standing every hour. During each 5-hr condition, participants consumed two identical, standardized meals. Blood samples, blood pressure, and heart rate were collected every 30 minutes. Endothelial function of the superficial femoral artery was measured at baseline and end of each 5-hr condition using flow-mediated dilation (FMD). Participants completed each condition on separate days, in randomized order. This feasibility pilot study was not powered to detect statistically significant differences in the various outcomes, however, analytic methods (mixed models) were used to test statistical significance within the small sample size. Nine participants completed all 4 study visits, one participant completed 3 study visits and then was lost to follow up. Net incremental area under the curve (iAUC) values for postprandial plasma glucose and insulin during the 5-hr sitting interruption conditions were not significantly different compared to the control condition. Exploratory analyses revealed that the 2-minute standing every 20 minutes and the 2-minute walking every hour conditions were associated with a significantly lower glycemic response to the second meal compared to the first meal (i.e., condition-matched 2-hour post-lunch glucose iAUC was lower than 2-hour post-breakfast glucose iAUC) that withstood Bonferroni correction (p = 0.0024 and p = 0.0084, respectively). Using allometrically scaled data, the 10-minute standing every hour condition resulted in an improved FMD response, which was significantly greater than the control condition after Bonferroni correction (p = 0.0033). This study suggests that brief interruptions in prolonged sitting time have modality-specific glucoregulatory and vascular benefits and are feasible in an older adult population. Larger laboratory and real-world intervention studies of pragmatic and effective methods to change sitting habits are needed. ClinicalTrials.gov NCT02743286.
Power system monitoring and source control of the Space Station Freedom DC power system testbed
NASA Technical Reports Server (NTRS)
Kimnach, Greg L.; Baez, Anastacio N.
1992-01-01
Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.
Power system monitoring and source control of the Space Station Freedom dc-power system testbed
NASA Technical Reports Server (NTRS)
Kimnach, Greg L.; Baez, Anastacio N.
1992-01-01
Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.
Surveying DNA Elements within Functional Genes of Heterocyst-Forming Cyanobacteria
Hilton, Jason A.; Meeks, John C.; Zehr, Jonathan P.
2016-01-01
Some cyanobacteria are capable of differentiating a variety of cell types in response to environmental factors. For instance, in low nitrogen conditions, some cyanobacteria form heterocysts, which are specialized for N2 fixation. Many heterocyst-forming cyanobacteria have DNA elements interrupting key N2 fixation genes, elements that are excised during heterocyst differentiation. While the mechanism for the excision of the element has been well-studied, many questions remain regarding the introduction of the elements into the cyanobacterial lineage and whether they have been retained ever since or have been lost and reintroduced. To examine the evolutionary relationships and possible function of DNA sequences that interrupt genes of heterocyst-forming cyanobacteria, we identified and compared 101 interruption element sequences within genes from 38 heterocyst-forming cyanobacterial genomes. The interruption element lengths ranged from about 1 kb (the minimum able to encode the recombinase responsible for element excision), up to nearly 1 Mb. The recombinase gene sequences served as genetic markers that were common across the interruption elements and were used to track element evolution. Elements were found that interrupted 22 different orthologs, only five of which had been previously observed to be interrupted by an element. Most of the newly identified interrupted orthologs encode proteins that have been shown to have heterocyst-specific activity. However, the presence of interruption elements within genes with no known role in N2 fixation, as well as in three non-heterocyst-forming cyanobacteria, indicates that the processes that trigger the excision of elements may not be limited to heterocyst development or that the elements move randomly within genomes. This comprehensive analysis provides the framework to study the history and behavior of these unique sequences, and offers new insight regarding the frequency and persistence of interruption elements in heterocyst-forming cyanobacteria. PMID:27206019
Surveying DNA Elements within Functional Genes of Heterocyst-Forming Cyanobacteria.
Hilton, Jason A; Meeks, John C; Zehr, Jonathan P
2016-01-01
Some cyanobacteria are capable of differentiating a variety of cell types in response to environmental factors. For instance, in low nitrogen conditions, some cyanobacteria form heterocysts, which are specialized for N2 fixation. Many heterocyst-forming cyanobacteria have DNA elements interrupting key N2 fixation genes, elements that are excised during heterocyst differentiation. While the mechanism for the excision of the element has been well-studied, many questions remain regarding the introduction of the elements into the cyanobacterial lineage and whether they have been retained ever since or have been lost and reintroduced. To examine the evolutionary relationships and possible function of DNA sequences that interrupt genes of heterocyst-forming cyanobacteria, we identified and compared 101 interruption element sequences within genes from 38 heterocyst-forming cyanobacterial genomes. The interruption element lengths ranged from about 1 kb (the minimum able to encode the recombinase responsible for element excision), up to nearly 1 Mb. The recombinase gene sequences served as genetic markers that were common across the interruption elements and were used to track element evolution. Elements were found that interrupted 22 different orthologs, only five of which had been previously observed to be interrupted by an element. Most of the newly identified interrupted orthologs encode proteins that have been shown to have heterocyst-specific activity. However, the presence of interruption elements within genes with no known role in N2 fixation, as well as in three non-heterocyst-forming cyanobacteria, indicates that the processes that trigger the excision of elements may not be limited to heterocyst development or that the elements move randomly within genomes. This comprehensive analysis provides the framework to study the history and behavior of these unique sequences, and offers new insight regarding the frequency and persistence of interruption elements in heterocyst-forming cyanobacteria.
Fang, B L; Qian, S Y; Jia, X L; Li, Z; Liu, J
2016-09-01
To analyze the interruptions of enteral nutrition (EN) and it's relationship to prognosis in children with sepsis in pediatric intensive care unit (PICU). Daily EN intake and reasons for EN interruptions were prospectively observed and recorded in children with sepsis who were admitted to our PICU from November 2012 to April 2013. Clinical prognosis was compared between children with and without EN interruptions by t, rank-sum and χ(2) tests. Totally 60 consecutive children were included, 42 males, median age 9.67 (5.36, 37.0) months; 50 children suffered from EN interruptions, while 10 children did not. Median time to EN initiation was 2.59 (1.53, 3.67) h; EN was interrupted in 83% (50/60) of children, for a total of 108 times and 696 h, the most common reasons were fibrobronchoscopy and radiologic procedures, 27 and 29 times respectively. Children spent 0.04 (0.02, 0.08) of their total observation period without EN nutrition due to EN interruptions, and was not correlated with pediatric critically ill score (r=0.12, P=0.38). Children with EN interruptions suffered from longer PICU duration ((12±7) vs. (7±4) d, t=2.18, P=0.03), but there was no significant difference in the 28(th) hospital day's mortality between these two groups (6 cases vs. 1 case, χ(2)=0.00, P=1.00). EN is frequently interrupted due to procedures needed fasting, EN intolerance and other reasons in children with sepsis. EN interruptions may have something to do with prolonged PICU length of stay, but the relationship needs to be examined in future studies.
On-chip temperature-based digital signal processing for customized wireless microcontroller
NASA Astrophysics Data System (ADS)
Farhah Razanah Faezal, Siti; Isa, Mohd Nazrin Md; Harun, Azizi; Nizam Mohyar, Shaiful; Bahari Jambek, Asral
2017-11-01
Increases in die size and power density inside system-on-chip (SoC) design have brought thermal issue inside the system. Uneven heat-up and increasing in temperature offset on-chip has become a major factor that can limits the system performance. This paper presents the design and simulation of a temperature-based digital signal processing for modern system-on-chip design using the Verilog HDL. This design yields continuous monitoring of temperature and reacts to specified conditions. The simulation of the system has been done on Altera Quartus Software v. 14. With system above, microcontroller can achieve nominal power dissipation and operation is within the temperature range due to the incorporate of an interrupt-based system.
62. VIEW LOOKING NORTHWEST AT THE OIL FILLED CIRCUIT BREAKER ...
62. VIEW LOOKING NORTHWEST AT THE OIL FILLED CIRCUIT BREAKER FOR GENERATOR NUMBER 1. CIRCUIT BREAKERS ARE AUTOMATED SWITCHES WHICH DISCONNECT THE GENERATORS FROM THE LINE WHEN SHORT CIRCUITS OCCUR. WHEN CIRCUITS INVOLVING HIGH CURRENTS AND VOLTAGES ARE BROKEN, THE AIR SURROUNDING MECHANICAL PARTS OF THE SWITCH BECOMES IONIZED AND CONTINUES TO CONDUCT ELECTRIC POWER ACROSS ANY GAP IN THE SWITCH CONTACTS. TO PREVENT THIS AND INSURE A POSITIVE INTERRUPTION OF CURRENT, THE SWITCH CONTACTS ARE IMMERSED IN A CONTAINER OF OIL. THE OIL DOES NOT SUPPORT THE FORMATION OF AN ARC AND EFFECTIVELY CUTS OFF THE CURRENT WHEN THE SWITCH CONTACTS ARE OPENED. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT
Fritts, T.H.
2002-01-01
The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978-1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.
Diffusion with stochastic resetting at power-law times.
Nagar, Apoorva; Gupta, Shamik
2016-06-01
What happens when a continuously evolving stochastic process is interrupted with large changes at random intervals τ distributed as a power law ∼τ^{-(1+α)};α>0? Modeling the stochastic process by diffusion and the large changes as abrupt resets to the initial condition, we obtain exact closed-form expressions for both static and dynamic quantities, while accounting for strong correlations implied by a power law. Our results show that the resulting dynamics exhibits a spectrum of rich long-time behavior, from an ever-spreading spatial distribution for α<1, to one that is time independent for α>1. The dynamics has strong consequences on the time to reach a distant target for the first time; we specifically show that there exists an optimal α that minimizes the mean time to reach the target, thereby offering a step towards a viable strategy to locate targets in a crowded environment.
Johnson, Maree; Weidemann, Gabrielle; Adams, Rebecca; Manias, Elizabeth; Levett-Jones, Tracy; Aguilar, Vicki; Everett, Bronwyn
The aim of this qualitative study was to examine the nature of interruptions during medication administration. Focus groups were conducted with medical/surgical nurses (n = 15), critical care nurses (n = 13), and nurse managers/educators/specialists (n = 6). Most interruptions (78%) were predictable. Nurse-adopted strategies included blocking, engaging, mediating, multitasking, and preventing. Educational content was developed that relates behavioral strategies to respond to predictable and unpredictable interruptions.
Nano Superconducting Quantum Interference device: A powerful tool for nanoscale investigations
NASA Astrophysics Data System (ADS)
Granata, Carmine; Vettoliere, Antonio
2016-02-01
The magnetic sensing at nanoscale level is a promising and interesting research topic of nanoscience. Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems. The study of small spin cluster, like magnetic molecules and nanoparticles, single electron, cold atom clouds, is one of the most stimulating challenges of applied and basic research of the next years. In particular, the magnetic nanoparticle investigation plays a fundamental role for the modern material science and its relative technological applications like ferrofluids, magnetic refrigeration and biomedical applications, including drug delivery, hyper-thermia cancer treatment and magnetic resonance imaging contrast-agent. Actually, one of the most ambitious goals of the high sensitivity magnetometry is the detection of elementary magnetic moment or spin. In this framework, several efforts have been devoted to the development of a high sensitivity magnetic nanosensor pushing sensing capability to the individual spin level. Among the different magnetic sensors, Superconducting QUantum Interference Devices (SQUIDs) exhibit an ultra high sensitivity and are widely employed in numerous applications. Basically, a SQUID consists of a superconducting ring (sensitive area) interrupted by two Josephson junctions. In the recent years, it has been proved that the magnetic response of nano-objects can be effectively measured by using a SQUID with a very small sensitive area (nanoSQUID). In fact, the sensor noise, expressed in terms of the elementary magnetic moment (spin or Bohr magneton), is linearly dependent on the SQUID loop side length. For this reason, SQUIDs have been progressively miniaturized in order to improve the sensitivity up to few spin per unit of bandwidth. With respect to other techniques, nanoSQUIDs offer the advantage of direct measurement of magnetization changes in small spin systems. In this review, we focus on nanoSQUIDs and its applications. In particular, we will discuss the motivations, the theoretical aspects, the fabrication techniques, the different nanoSQUIDs and the relative nanoscale applications.
Goto, Aya; Bromet, Evelyn J; Fujimori, Kenya
2015-03-26
Mothers of young children are at high-risk for developing adverse mental health effects following a nuclear accident. Using the Japanese pregnancy registration system, the prefecture of Fukushima launched a population-based survey of women who were pregnant at the time of the Fukushima nuclear accident in order to assess their and their newborns' health. In this paper, we focus on the results of a screen for depressive symptoms among new mothers and its association with geographical region and interruption of obstetrical care after the Fukushima nuclear accident, which occurred after the Great East Japan Earthquake on March 11, 2011. The survey targeted women who lived in Fukushima prefecture and who had registered their pregnancies between August 1, 2010 and July 31, 2011. Among the 16,001 women targeted, 9,321 returned the questionnaires (response proportion = 58.3%) and data from 8,196 women with singleton live births were analyzed. The main outcome measure was a standard two-item depression screen. Regional radiation levels were determined from the prefecture's periodical reports, and interruption in obstetrical care after the Fukushima nuclear accident was determined from mothers' individual responses to the questionnaire. Among the 8,196 women, 2,262 (28%) screened positive for depressive symptoms. After adjusting for maternal and infant characteristics, both mothers in Soso, the region in which the nuclear power plant is located, and mothers that had changed obstetrical care facilities were significantly more likely to screen positive for depression. In contrast, mothers in Iwaki and Aizu, regions with relatively low radiation levels, were significantly less likely to screen positive for depression. Our findings suggest that improving mental health support for mothers with infants should be a high priority in the acute phase of nuclear disaster response. We further recommend that in the strategic provisioning of parental support, close attention should be paid to regional variations in negative mental health consequences, particularly to those who experienced an interruption in their obstetrical care.
No patch technique for complete atrioventricular canal repair.
Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto
2006-08-01
We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.
Apparatus for and method of testing an electrical ground fault circuit interrupt device
Andrews, L.B.
1998-08-18
An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined. 17 figs.
Apparatus for and method of testing an electrical ground fault circuit interrupt device
Andrews, Lowell B.
1998-01-01
An apparatus for testing a ground fault circuit interrupt device includes a processor, an input device connected to the processor for receiving input from an operator, a storage media connected to the processor for storing test data, an output device connected to the processor for outputting information corresponding to the test data to the operator, and a calibrated variable load circuit connected between the processor and the ground fault circuit interrupt device. The ground fault circuit interrupt device is configured to trip a corresponding circuit breaker. The processor is configured to receive signals from the calibrated variable load circuit and to process the signals to determine a trip threshold current and/or a trip time. A method of testing the ground fault circuit interrupt device includes a first step of providing an identification for the ground fault circuit interrupt device. Test data is then recorded in accordance with the identification. By comparing test data from an initial test with test data from a subsequent test, a trend of performance for the ground fault circuit interrupt device is determined.
Fast interrupt platform for extended DOS
NASA Technical Reports Server (NTRS)
Duryea, T. W.
1995-01-01
Extended DOS offers the unique combination of a simple operating system which allows direct access to the interrupt tables, 32 bit protected mode access to 4096 MByte address space, and the use of industry standard C compilers. The drawback is that fast interrupt handling requires both 32 bit and 16 bit versions of each real-time process interrupt handler to avoid mode switches on the interrupts. A set of tools has been developed which automates the process of transforming the output of a standard 32 bit C compiler to 16 bit interrupt code which directly handles the real mode interrupts. The entire process compiles one set of source code via a make file, which boosts productivity by making the management of the compile-link cycle very simple. The software components are in the form of classes written mostly in C. A foreground process written as a conventional application which can use the standard C libraries can communicate with the background real-time classes via a message passing mechanism. The platform thus enables the integration of high performance real-time processing into a conventional application framework.
Gabriel, Matwale; Tukahebwa, Edridah; Onapa, Ambrose Winston; Tinkitina, Benjamin; Tukesiga, Ephraim; Nyaraga, Michael; Auma, Anna Mary; Habomugisha, Peace; Byamukama, Edson; Oguttu, David; Katabarwa, Moses; Unnasch, Thomas Raymond
2017-01-01
Intervention Few studies have documented the interruption of onchocerciasis and Lymphatic Filariasis (LF) by integrated chemotherapy in Uganda. The study describes the interruption of transmission of the two diseases co-endemic in Obongi focus, north western Uganda. Base line data for Onchocerciasis and LF were collected in 1994 and 2006, respectively. Annual mass drug administration for onchocerciasis (Ivermectin) and Lymphatic Filariasis (Ivermectin + albendazole) was conducted for 20 and 6 years, respectively. Thereafter, assessments by skin snip, larval searches in rivers and human landing catches were performed. Children <10 years were screened for IgG4 antibodies using Ov16 ELISA technique in 2013. LF Pre-TAS and TAS1 were conducted in sentinel sites. ITN coverage and utilization for the implementation unit was also reported. Intervention coverage Onchocerciasis treatment coverage was <80% but improved with the introduction of CDTI in 1999. While for LF, effective coverage of >65% was achieved in the six treatment rounds. Household ownership of ITN’s and utilization was 96% and 72.4%., respectively. Impact Parasitological examinations conducted for onchocerciasis among 807 adults and children, revealed a reduction in mf prevalence from 58% in 1994 to 0% in 2012. Entomological monitoring conducted at the two sites had no single Simulium damnosum fly caught. Serological analysis using Ov16 ELISA for onchocerciasis revealed that out of the 3,308 children <10 years old screened in 2013, only 3/3308 (0.091%) positive cases were detected. All Ov16 positive children were negative when tested for patent infection by skin snip PCR. A reduction in LF microfilaria prevalence from 2.5% (n = 13/522) in 2006 to 0.0% (n = 602) in 2014 was observed. LF TAS1 conducted in 2015 among 1,532 children 6–7 years, all were negative for antigens of W. bancrofti. Conclusion The results concluded that interruption of onchocerciasis and LF has been achieved. PMID:29253862
Apparatuses and methods for laser reading of thermoluminescent phosphors
Braunlich, Peter F.; Tetzlaff, Wolfgang
1989-01-01
Apparatuses and methods for rapidly reading thermoluminescent phosphors to determine the amount of luminescent energy stored therein. The stored luminescent energy is interpreted as a measure of the total exposure of the thermoluminescent phosphor to ionizing radiation. The thermoluminescent phosphor reading apparatus uses a laser to generate a laser beam. The laser beam power level is monitored by a laser power detector and controlled to maintain the power level at a desired value or values which can vary with time. A shutter or other laser beam interrupting means is used to control exposure of the thermoluminescent phosphor to the laser beam. The laser beam can be equalized using an opitcal equalizer so that the laser beam has an approximately uniform power density across the beam. The heated thermoluminescent phosphor emits a visible or otherwise detectable luminescent emission which is measured as an indication of the radiation exposure of the thermoluminscent phosphors. Also disclosed are preferred signal processing and control circuits including one system using a digital computer. Also disclosed are time-profiled laser power cycles for pre-anneal, read and post-anneal treatment of phosphors.
Demonstration program for Omega receiver prototype microcomputer data processing
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1976-01-01
The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.
Effect of current vehicle’s interruption on traffic stability in cooperative car-following theory
NASA Astrophysics Data System (ADS)
Zhang, Geng; Liu, Hui
2017-12-01
To reveal the impact of the current vehicle’s interruption information on traffic flow, a new car-following model with consideration of the current vehicle’s interruption is proposed and the influence of the current vehicle’s interruption on traffic stability is investigated through theoretical analysis and numerical simulation. By linear analysis, the linear stability condition of the new model is obtained and the negative influence of the current vehicle’s interruption on traffic stability is shown in the headway-sensitivity space. Through nonlinear analysis, the modified Korteweg-de Vries (mKdV) equation of the new model near the critical point is derived and it can be used to describe the propagating behavior of the traffic density wave. Finally, numerical simulation confirms the analytical results, which shows that the current vehicle’s interruption information can destabilize traffic flow and should be considered in real traffic.
Handling cycle slips in GPS data during ionospheric plasma bubble events
NASA Astrophysics Data System (ADS)
Banville, S.; Langley, R. B.; Saito, S.; Yoshihara, T.
2010-12-01
During disturbed ionospheric conditions such as the occurrence of plasma bubbles, the phase and amplitude of the electromagnetic waves transmitted by GPS satellites undergo rapid fluctuations called scintillation. When this phenomenon is observed, GPS receivers are more prone to signal tracking interruptions, which prevent continuous measurement of the total electron content (TEC) between a satellite and the receiver. In order to improve TEC monitoring, a study was conducted with the goal of reducing the effects of signal tracking interruptions by correcting for "cycle slips," an integer number of carrier wavelengths not measured by the receiver during a loss of signal lock. In this paper, we review existing cycle-slip correction methods, showing that the characteristics associated with ionospheric plasma bubbles (rapid ionospheric delay fluctuations, data gaps, increased noise, etc.) prevent reliable correction of cycle slips. Then, a reformulation of the "geometry-free" model conventionally used for ionospheric studies with GPS is presented. Geometric information is used to obtain single-frequency estimates of TEC variations during momentary L2 signal interruptions, which also provides instantaneous cycle-slip correction capabilities. The performance of this approach is assessed using data collected on Okinawa Island in Japan during a plasma bubble event that occurred on 23 March 2004. While an improvement in the continuity of TEC time series is obtained, we question the reliability of any cycle-slip correction technique when discontinuities on both GPS legacy frequencies occur simultaneously for more than a few seconds.
Huckels-Baumgart, Saskia; Baumgart, André; Buschmann, Ute; Schüpfer, Guido; Manser, Tanja
2016-12-21
Interruptions and errors during the medication process are common, but published literature shows no evidence supporting whether separate medication rooms are an effective single intervention in reducing interruptions and errors during medication preparation in hospitals. We tested the hypothesis that the rate of interruptions and reported medication errors would decrease as a result of the introduction of separate medication rooms. Our aim was to evaluate the effect of separate medication rooms on interruptions during medication preparation and on self-reported medication error rates. We performed a preintervention and postintervention study using direct structured observation of nurses during medication preparation and daily structured medication error self-reporting of nurses by questionnaires in 2 wards at a major teaching hospital in Switzerland. A volunteer sample of 42 nurses was observed preparing 1498 medications for 366 patients over 17 hours preintervention and postintervention on both wards. During 122 days, nurses completed 694 reporting sheets containing 208 medication errors. After the introduction of the separate medication room, the mean interruption rate decreased significantly from 51.8 to 30 interruptions per hour (P < 0.01), and the interruption-free preparation time increased significantly from 1.4 to 2.5 minutes (P < 0.05). Overall, the mean medication error rate per day was also significantly reduced after implementation of the separate medication room from 1.3 to 0.9 errors per day (P < 0.05). The present study showed the positive effect of a hospital-based intervention; after the introduction of the separate medication room, the interruption and medication error rates decreased significantly.
Raunsø, Jakob; Selmer, Christian; Olesen, Jonas Bjerring; Charlot, Mette Gitz; Olsen, Anne-Marie S; Bretler, Ditte-Marie; Nielsen, Jørn Dalsgaard; Dominguez, Helena; Gadsbøll, Niels; Køber, Lars; Gislason, Gunnar H; Torp-Pedersen, Christian; Hansen, Morten Lock
2012-08-01
It is presently unknown whether patients with atrial fibrillation (AF) are at increased risk of thrombo-embolic adverse events after interruption of warfarin treatment. The purpose of this study was to assess the risk and timing of thrombo-embolism after warfarin treatment interruption. A retrospective, nationwide cohort study of all patients in Denmark treated with warfarin after a first hospitalization with AF in the period 1997-2008. Incidence rate ratios (IRRs) of thrombo-embolic events and all-cause mortality were calculated using the Poisson regression analyses. In total, 48 989 AF patients receiving warfarin treatment were included. Of these, 35 396 patients had at least one episode of warfarin treatment interruption. In all, 8255 deaths or thrombo-embolic events occurred during treatment interruption showing an initial clustering of events with 2717, 835, 500, and 427 events occurring during 0-90, 91-180, 181-270, and 271-360 days after treatment interruption, respectively. Correspondingly, the crude incidence rates were 31.6, 17.7, 12.3, and 11.4 events per 100 patient-years. In a multivariable analysis, the first 90-day interval of treatment interruption was associated with a markedly higher risk of death or thrombo-embolism (IRR 2.5; 95% confidence interval 2.3-2.8) vs. the interval of 271-360 days. In patients with AF, an interruption of warfarin treatment is associated with a significantly increased short-term risk of death or thrombo-embolic events within the first 90 days of treatment interruption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Allan; Mills, Evan; Vine, Edward.
The promotion of technologies and services for insurance loss reduction and loss prevention is as old as the fields of insurance and risk management. This report addresses a new category of risk management opportunity involving technologies and procedures that use energy more efficiently or supply renewable energy. While the economic benefits of these measures are of interest to energy consumers seeking to reduce their energy expenditures, we have found that they also offer a novel and largely untapped pathway for achieving traditional risk management objectives. Most of the technologies described in this report were supported by government- sponsored RD Dmore » programs over many years of effort. These technologies have many benefits, including insurance loss reduction and prevention. The insurance and risk management communities could take advantage of these technologies, either independently or in cost-sharing partnerships with existing R D programs. In this report, we present a compilation of energy-efficiency and renewable energy projects (e.g., energy-efficient halogen torchiere replacements) and techniques (e.g., infrared cameras to detect fire hazards) that are currently being investigated at the U.S. Department of Energy's national laboratories and which the insurance and risk management communities could encourage their customers to use to address their short-term and long-term needs. Once the loss-prevention benefits of these technologies and techniques (many of which are not yet available in the marketplace) are sufficiently demonstrated, insurers can promote their use through informational programs and perhaps financial incentives (e.g., risk-adjusted insurance premium schemes) through the insurance regulatory and rate-making processes. We identified 78 technologies and techniques being investigated by nine national laboratories which can help to reduce insurance losses and manage risks, especially those associated with power failures, fire and wind damage, and home or workplace indoor air quality hazards. All help to reduce insurance losses in one or more of the following categories: boiler and machinery, builder's risk, business interruption, commercial property insurance, completed operations liability, comprehensive general liability, contractors liability, environmental liability, product liability, professional liability, service interruption, workers' compensation, health/life insurance, and homeowners insurance. We identify examples of existing collaborations between the national laboratories and the insurance industry, and indicate research activities being conducted by the insurance and risk management communities that would benefit from the work of the national laboratories. We also describe some of the risk factors associated with energy-efficient and renewable energy technologies. For the future, significant progress could be made through interdisciplinary collaborative applied research (i.e., integrating the actuarial sciences with the physical or engineering sciences). This collaboration could be sponsored jointly by the U.S. Department of Energy and the insurance and risk management communities (as well as working through the insurance regulatory and rate-making processes).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Allan; Mills, Evan; Vine, Edward
The promotion of technologies and services for insurance loss reduction and loss prevention is as old as the fields of insurance and risk management. This report addresses a new category of risk management opportunity involving technologies and procedures that use energy more efficiently or supply renewable energy. While the economic benefits of these measures are of interest to energy consumers seeking to reduce their energy expenditures, we have found that they also offer a novel and largely untapped pathway for achieving traditional risk management objectives. Most of the technologies described in this report were supported by government- sponsored RD&D programsmore » over many years of effort. These technologies have many benefits, including insurance loss reduction and prevention. The insurance and risk management communities could take advantage of these technologies, either independently or in cost-sharing partnerships with existing R&D programs. In this report, we present a compilation of energy-efficiency and renewable energy projects (e.g., energy-efficient halogen torchiere replacements) and techniques (e.g., infrared cameras to detect fire hazards) that are currently being investigated at the U.S. Department of Energy's national laboratories and which the insurance and risk management communities could encourage their customers to use to address their short-term and long-term needs. Once the loss-prevention benefits of these technologies and techniques (many of which are not yet available in the marketplace) are sufficiently demonstrated, insurers can promote their use through informational programs and perhaps financial incentives (e.g., risk-adjusted insurance premium schemes) through the insurance regulatory and rate-making processes. We identified 78 technologies and techniques being investigated by nine national laboratories which can help to reduce insurance losses and manage risks, especially those associated with power failures, fire and wind damage, and home or workplace indoor air quality hazards. All help to reduce insurance losses in one or more of the following categories: boiler and machinery, builder's risk, business interruption, commercial property insurance, completed operations liability, comprehensive general liability, contractors liability, environmental liability, product liability, professional liability, service interruption, workers' compensation, health/life insurance, and homeowners insurance. We identify examples of existing collaborations between the national laboratories and the insurance industry, and indicate research activities being conducted by the insurance and risk management communities that would benefit from the work of the national laboratories. We also describe some of the risk factors associated with energy-efficient and renewable energy technologies. For the future, significant progress could be made through interdisciplinary collaborative applied research (i.e., integrating the actuarial sciences with the "physical" or "engineering" sciences). This collaboration could be sponsored jointly by the U.S. Department of Energy and the insurance and risk management communities (as well as working through the insurance regulatory and rate-making processes).« less
Sex Differences in Children's Conversation.
ERIC Educational Resources Information Center
Esposito, Anita
1979-01-01
The recorded conversations of 40 preschool children in small groups were analyzed for interruptions, overlaps, lapses, and gaps. Significant differences were found between heterogeneous and homogeneous groups for interruptions, with boys interrupting girls at a two to one ratio. (Author/RL)
How to Interrupt Oppressive Behavior.
ERIC Educational Resources Information Center
McClintock, Mary
1990-01-01
Describes continuum of responses to examples of race-, handicap-, and sex discrimination by participants and staff of camping programs. Recommends following actions toward social justice: educating oneself; interrupting negative behavior; interrupting and educating; supporting proactive response; and initiating proactive response. Includes…
Reducing the Disruptive Effects of Interruptions With Noninvasive Brain Stimulation.
Blumberg, Eric J; Foroughi, Cyrus K; Scheldrup, Melissa R; Peterson, Matthew S; Boehm-Davis, Debbie A; Parasuraman, Raja
2015-09-01
The authors determine whether transcranial direct current stimulation (tDCS) can reduce resumption time when an ongoing task is interrupted. Interruptions are common and disruptive. Working memory capacity has been shown to predict resumption lag (i.e., time to successfully resume a task after interruption). Given that tDCS applied to brain areas associated with working memory can enhance performance, tDCS has the potential to improve resumption lag when a task is interrupted. Participants were randomly assigned to one of four groups that received anodal (active) stimulation of 2 mA tDCS to one of two target brain regions, left and right dorsolateral prefrontal cortex (DLPFC), or to one of two control areas, active stimulation of the left primary motor cortex or sham stimulation of the right DLPFC, while completing a financial management task that was intermittently interrupted with math problem solving. Anodal stimulation to the right and left DLPFC significantly reduced resumption lags compared to the control conditions (sham and left motor cortex stimulation). Additionally, there was no speed-accuracy tradeoff (i.e., the improvement in resumption time was not accompanied by an increased error rate). Noninvasive brain stimulation can significantly decrease resumption lag (improve performance) after a task is interrupted. Noninvasive brain stimulation offers an easy-to-apply tool that can significantly improve interrupted task performance. © 2014, Human Factors and Ergonomics Society.
Patel, Sunil V; Paskar, David D; Nelson, Richard L; Vedula, Satyanarayana S; Steele, Scott R
2017-11-03
Surgeons who perform laparotomy have a number of decisions to make regarding abdominal closure. Material and size of potential suture types varies widely. In addition, surgeons can choose to close the incision in anatomic layers or mass ('en masse'), as well as using either a continuous or interrupted suturing technique, of which there are different styles of each. There is ongoing debate as to which suturing techniques and suture materials are best for achieving definitive wound closure while minimising the risk of short- and long-term complications. The objectives of this review were to identify the best available suture techniques and suture materials for closure of the fascia following laparotomy incisions, by assessing the following comparisons: absorbable versus non-absorbable sutures; mass versus layered closure; continuous versus interrupted closure techniques; monofilament versus multifilament sutures; and slow absorbable versus fast absorbable sutures. Our objective was not to determine the single best combination of suture material and techniques, but to compare the individual components of abdominal closure. On 8 February 2017 we searched CENTRAL, MEDLINE, Embase, two trials registries, and Science Citation Index. There were no limitations based on language or date of publication. We searched the reference lists of all included studies to identify trials that our searches may have missed. We included randomised controlled trials (RCTs) that compared suture materials or closure techniques, or both, for fascial closure of laparotomy incisions. We excluded trials that compared only types of skin closures, peritoneal closures or use of retention sutures. We abstracted data and assessed the risk of bias for each trial. We calculated a summary risk ratio (RR) for the outcomes assessed in the review, all of which were dichotomous. We used random-effects modelling, based on the heterogeneity seen throughout the studies and analyses. We completed subgroup analysis planned a priori for each outcome, excluding studies where interventions being compared differed by more than one component, making it impossible to determine which variable impacted on the outcome, or the possibility of a synergistic effect. We completed sensitivity analysis, excluding trials with at least one trait with high risk of bias. We assessed the quality of evidence using the GRADEpro guidelines. Fifty-five RCTs with a total of 19,174 participants met the inclusion criteria and were included in the meta-analysis. Included studies were heterogeneous in the type of sutures used, methods of closure and patient population. Many of the included studies reported multiple comparisons.For our primary outcome, the proportion of participants who developed incisional hernia at one year or more of follow-up, we did not find evidence that suture absorption (absorbable versus non-absorbable sutures, RR 1.07, 95% CI 0.86 to 1.32, moderate-quality evidence; or slow versus fast absorbable sutures, RR 0.81, 95% CI 0.63 to 1.06, moderate-quality evidence), closure method (mass versus layered, RR 1.92, 95% CI 0.58 to 6.35, very low-quality evidence) or closure technique (continuous versus interrupted, RR 1.01, 95% CI 0.76 to 1.35, moderate-quality evidence) resulted in a difference in the risk of incisional hernia. We did, however, find evidence to suggest that monofilament sutures reduced the risk of incisional hernia when compared with multifilament sutures (RR 0.76, 95% CI 0.59 to 0.98, I 2 = 30%, moderate-quality evidence).For our secondary outcomes, we found that none of the interventions reduced the risk of wound infection, whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.99, 95% CI 0.84 to 1.17, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.16, 95% CI 0.85 to 1.57, moderate-quality evidence), closure method (mass versus layered, RR 0.93, 95% CI 0.67 to 1.30, low-quality evidence) or closure technique (continuous versus interrupted, RR 1.13, 95% CI 0.96 to 1.34, moderate-quality evidence).Similarily, none of the interventions reduced the risk of wound dehiscence whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.78, 95% CI 0.55 to 1.10, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.55, 95% CI 0.92 to 2.61, moderate-quality evidence), closure method (mass versus layered, RR 0.69, 95% CI 0.31 to 1.52, moderate-quality evidence) or closure technique (continuous versus interrupted, RR 1.21, 95% CI 0.90 to 1.64, moderate-quality evidence).Absorbable sutures, compared with non-absorbable sutures (RR 0.49, 95% CI 0.26 to 0.94, low-quality evidence) reduced the risk of sinus or fistula tract formation. None of the other comparisons showed a difference (slow versus fast absorbable sutures, RR 0.88, 95% CI 0.05 to 16.05, very low-quality evidence; mass versus layered, RR 0.49, 95% CI 0.15 to 1.62, low-quality evidence; continuous versus interrupted, RR 1.51, 95% CI 0.64 to 3.61, very low-quality evidence). Based on this moderate-quality body of evidence, monofilament sutures may reduce the risk of incisional hernia. Absorbable sutures may also reduce the risk of sinus or fistula tract formation, but this finding is based on low-quality evidence.We had serious concerns about the design or reporting of several of the 55 included trials. The comparator arms in many trials differed by more than one component, making it impossible to attribute differences between groups to any one component. In addition, the patient population included in many of the studies was very heterogeneous. Trials included both emergency and elective cases, different types of disease pathology (e.g. colon surgery, hepatobiliary surgery, etc.) or different types of incisions (e.g. midline, paramedian, subcostal).Consequently, larger, high-quality trials to further address this clinical challenge are warranted. Future studies should ensure that proper randomisation and allocation techniques are performed, wound assessors are blinded, and that the duration of follow-up is adequate. It is important that only one type of intervention is compared between groups. In addition, a homogeneous patient population would allow for a more accurate assessment of the interventions.
Dither Gyro Scale Factor Calibration: GOES-16 Flight Experience
NASA Technical Reports Server (NTRS)
Reth, Alan D.; Freesland, Douglas C.; Krimchansky, Alexander
2018-01-01
This poster is a sequel to a paper presented at the 34th Annual AAS Guidance and Control Conference in 2011, which first introduced dither-based calibration of gyro scale factors. The dither approach uses very small excitations, avoiding the need to take instruments offline during gyro scale factor calibration. In 2017, the dither calibration technique was successfully used to estimate gyro scale factors on the GOES-16 satellite. On-orbit dither calibration results were compared to more traditional methods using large angle spacecraft slews about each gyro axis, requiring interruption of science. The results demonstrate that the dither technique can estimate gyro scale factors to better than 2000 ppm during normal science observations.
Yazdanpanah, Yazdan; Wolf, Lindsey L; Anglaret, Xavier; Gabillard, Delphine; Walensky, Rochelle P; Moh, Raoul; Danel, Christine; Sloan, Caroline E; Losina, Elena; Freedberg, Kenneth A
2010-01-01
International trials have shown that CD4+ T-cell-guided structured treatment interruptions (STI) of antiretroviral therapy (ART) lead to worse outcomes than continuous treatment. We simulated continuous ART and STI strategies with higher CD4+ T-cell interruption/reintroduction thresholds than those assessed in actual trials. Using a model of HIV, we simulated cohorts of African adults with different baseline CD4+ T-cell counts (< or = 200; 201-350; and 351-500 cells/microl). We varied ART initiation criteria (immediate; CD4+ T-cell count < 350 cells/microl or > or = 350 cells/microl with severe HIV-related disease; and CD4+ T-cell count <200 cells/microl or > or = 200 cells/microl with severe HIV-related disease), and ART interruption/reintroduction thresholds (350/250; 500/350; and 700/500 cells/microl). First-line therapy was non-nucleoside reverse transcriptase inhibitor (NNRTI)-based and second-line therapy was protease inhibitor (PI)-based. STI generally reduced life expectancy compared with continuous ART. Life expectancy increased with earlier ART initiation and higher interruption/reintroduction thresholds. STI reduced life expectancy by 48-69 and 11-30 months compared with continuous ART when interruption/reintroduction thresholds were 350/250 and 500/350 cells/microl, depending on ART initiation criteria. When patients interrupted/reintroduced ART at 700/500 cells/microl, life expectancies ranged from 2 months lower to 1 month higher than continuous ART. STI-related life expectancy increased with decreased risk of virological resistance after ART interruptions. STI with NNRTI-based regimens was almost always less effective than continuous treatment, regardless of interruption/reintroduction thresholds. The risks associated with STI decrease only if patients start ART earlier, interrupt/reintroduce treatment at very high CD4+ T-cell thresholds (700/500 cells/microl) and use first-line medications with higher resistance barriers, such as PIs.
Weigl, Matthias; Antoniadis, Sophia; Chiapponi, Costanza; Bruns, Christiane; Sevdalis, Nick
2015-01-01
Surgeons' intra-operative workload is critical for effective and safe surgical performance. Detrimental conditions in the operating room (OR) environment may add to perceived workload and jeopardize surgical performance and outcomes. This study aims to evaluate the impact of different intra-operative workflow interruptions on surgeons' capacity to manage their workload safely and efficiently. This was an observational study of intra-operative interruptions and self-rated workload in two surgical specialties (general, orthopedic/trauma surgery). Intra-operative interruptions were assessed via expert observation using a well-validated observation tool. Surgeons, nurses, and anesthesiologists assessed their intra-operative workload directly after case completion based on three items of the validated Surgery Task Load Index (mental demand, situational stress, distraction). A total of 56 elective cases (35 open, 21 laparoscopic) with 94 workload ratings were included. Mean intra-operative duration was 1 h 37 min. Intra-operative interruptions were on average observed 9.78 times per hour. People who entered/exited the OR (30.6 %) as well as telephone-/beeper-related disruptions (23.6 %) occurred most often. Equipment and OR environment-related interruptions were associated with highest interference with team functioning particularly in laparoscopic procedures. After identifying task and procedural influences, partial correlational analyses revealed that case-irrelevant communications were negatively associated with surgeons' mental fatigue and situational stress, whereas surgeons' reported distraction was increased by case-irrelevant communication and procedural disruptions. OR nurses' and anesthesiologists' perceived workload was also related to intra-operative interruption events. Our study documents the unique contribution of different interruptions on surgeons' workload; whereas case-irrelevant communications may be beneficial for mental fatigue and stress in routine cases, procedural interruptions and case-irrelevant communication may contribute to surgeons' mental focus deteriorating. Well-designed OR environments, surgical leadership, and awareness can help to control unnecessary interruptions for effective and safe surgical care.
Global interrupt and barrier networks
Blumrich, Matthias A.; Chen, Dong; Coteus, Paul W.; Gara, Alan G.; Giampapa, Mark E; Heidelberger, Philip; Kopcsay, Gerard V.; Steinmacher-Burow, Burkhard D.; Takken, Todd E.
2008-10-28
A system and method for generating global asynchronous signals in a computing structure. Particularly, a global interrupt and barrier network is implemented that implements logic for generating global interrupt and barrier signals for controlling global asynchronous operations performed by processing elements at selected processing nodes of a computing structure in accordance with a processing algorithm; and includes the physical interconnecting of the processing nodes for communicating the global interrupt and barrier signals to the elements via low-latency paths. The global asynchronous signals respectively initiate interrupt and barrier operations at the processing nodes at times selected for optimizing performance of the processing algorithms. In one embodiment, the global interrupt and barrier network is implemented in a scalable, massively parallel supercomputing device structure comprising a plurality of processing nodes interconnected by multiple independent networks, with each node including one or more processing elements for performing computation or communication activity as required when performing parallel algorithm operations. One multiple independent network includes a global tree network for enabling high-speed global tree communications among global tree network nodes or sub-trees thereof. The global interrupt and barrier network may operate in parallel with the global tree network for providing global asynchronous sideband signals.
Bower, Rachel A; Coad, Jane E; Manning, Joseph C; Pengelly, Theresa A
2018-02-01
In the paediatric intensive care unit (PICU), medication administration is challenging. Empirical studies demonstrate that interruptions occur frequently and that nurses are fundamental in the delivery of medication. However, little is known about nurse's decision making when interrupted during medication administration. Therefore, the objective is to understand decision making when interrupted during medication administration within the PICU. A qualitative study incorporating non-participant observation and audio recorded semi-structured interviews. A convenience sample of ten PICU nurses were interviewed. Each interview schedule was informed by two hours of observation which involved a further 29 PICU nurses. Data was analysed using Framework Analysis. A regional PICU located in a university teaching hospital in the United Kingdom. Analysis resulted in four overarching themes: (1) Guiding the medication process, (2) Concentration, focus and awareness, (3) Influences on interruptions (4) Impact and recovery CONCLUSION: Medication administration within the PICU is an essential but complex activity. Interruptions can impact on focus and concentration which can contribute to patient harm. Decision making by PICU nurses is influenced by interruption awareness, fluctuating levels of concentration, and responding to critically ill patient and families' needs. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith-Boughner, Lindsay
Many Earth systems cannot be studied directly. One cannot measure the velocities of convecting fluid in the Earth's core but can measure the magnetic field generated by these motions on the surface. Examining how the magnetic field changes over long periods of time, using power spectral density estimation provides insight into the dynamics driving the system. The changes in the magnetic field can also be used to study Earth properties - variations in magnetic fields outside of Earth like the ring-current induce currents to flow in the Earth, generating magnetic fields. Estimating the transfer function between the external changes and the induced response characterizes the electromagnetic response of the Earth. From this response inferences can be made about the electrical conductivity of the Earth. However, these types of time series, and many others have long breaks in the record with no samples available and limit the analysis. Standard methods require interpolation or section averaging, with associated problems of introducing bias or reducing the frequency resolution. Extending the methods of Fodor and Stark (2000), who adapt a set of orthogonal multi-tapers to compensate for breaks in sampling- an algorithm and software package for applying these techniques is developed. Methods of empirically estimating the average transfer function of a set of tapers and confidence intervals are also tested. These methods are extended for cross-spectral, coherence and transfer function estimation in the presence of noise. With these methods, new analysis of a highly interrupted ocean sediment core from the Oligocene (Hartl et al., 1993) reveals a quasi-periodic signal in the calibrated paleointensity time series at 2.5 cpMy. The power in the magnetic field during this period appears to be dominated by reversal rate processes with less overall power than the early Oligocene. Previous analysis of the early Oligocene by Constable et al. (1998) detected a signal near 8 cpMy. These results suggest that a strong magnetic field inhibits reversals and has more variability in shorter term field changes. Using over 9 years of data from the CHAMP low-Earth orbiting magnetic satellite and the techniques developed here, more robust estimates of the electromagnetic response of the Earth can be made. The tapers adapted for gaps provide flexibility to study the effects of local time, storm conditions on Earth's 1-D electromagnetic response as well as providing robust estimates of the C-response at longer periods than previous satellite studies.
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
43 CFR 3481.4 - Temporary interruption in coal severance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Temporary interruption in coal severance... LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) COAL EXPLORATION AND MINING OPERATIONS RULES General Provisions § 3481.4 Temporary interruption in coal severance. ...
1984-06-01
UNSOLINTERRUPT: ; Dismiss unsolicited Interrupt. POPR M<RI,RI,R2,R3,R4,R5> ; Restore RZ-R5 REI ; Return from interrupt. .SBTTL AVCANCEL. Cancel I/O routine...Dismiss unsolicited Interrupt. POPR M<R8,RI.R2,R3,R4,R5> ; Restore RN-R5 REI ; Return from interrupt. .SBTTL ODCANCEL, Cancel I/0 routine ++ I ODCANCEL...output buffer. ODREGDU4P: i Dump device registers MOVZBL ODNUMREGS,(Rg)+ i Store device register count. NOVZWL UCBSWODBYTCNT(RS),- aStore BYTE count
Mitigating Upsets in SRAM-Based FPGAs from the Xilinx Virtex 2 Family
NASA Technical Reports Server (NTRS)
Swift, G. M.; Yui, C. C.; Carmichael, C.; Koga, R.; George, J. S.
2003-01-01
Static random access memory (SRAM) upset rates in field programmable gate arrays (FPGAs) from the Xilinx Virtex 2 family have been tested for radiation effects on configuration memory, block RAM and the power-on-reset (POR) and SelectMAP single event functional interrupts (SEFIs). Dynamic testing has shown the effectiveness and value of Triple Module Redundancy (TMR) and partial reconfiguration when used in conjunction. Continuing dynamic testing for more complex designs and other Virtex 2 capabilities (i.e., I/O standards, digital clock managers (DCM), etc.) is scheduled.
Isolation contactor state control system
Bissontz, Jay E.
2017-05-16
A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.
Herzog, D.C.
1992-01-01
Geomagnetic storms are large and sometimes rapid fluctuations in the Earth's magnetic field that are related to disturbances on the Sun's surface. Although it is not widely recognized, these transient magnetic disturbances can be a significant hazard to people and property. Many of us know that the intensity of the auroral lights increases during magnetic storms, but few people realize that these storms can also cause massive power outages, interrupt radio communications and satellite operations, increase corrosion in oil and gas pipelines, and lead to spuriously high rejection rates in the manufacture of sensitive electronic equipment.
Chattanooga Electric Power Board Case Study Distribution Automation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, Jim; Melin, Alexander M.; Starke, Michael R.
In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities consideringmore » a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under normal operations, the investment in distribution automation has enabled a 43.5% reduction in annual outage minutes since 2012. This has led to an estimated total savings of $26.8 million per year. Examining a single severe weather event3, the distribution automation was able to restore power to 40,579 (nearly 56%) customers within 1–2 seconds and reduce outage minutes by 29.0%. This saved customers an estimated $23.2 million over the course of the storm.« less
Xu, Tingting; Zhou, Cong-Zhao; Xiao, Jianxi; Liu, Jinsong
2018-02-20
Naturally occurring interruptions in nonfibrillar collagen play key roles in molecular flexibility, collagen degradation, and ligand binding. The structural feature of the interruption sequences and the molecular basis for their functions have not been well studied. Here, we focused on a G5G type natural interruption sequence G-POALO-G from human type XIX collagen, a homotrimer collagen, as this sequence possesses distinct properties compared with those of a pathological similar Gly mutation sequence in collagen mimic peptides. We determined the crystal structures of the host-guest peptide (GPO) 3 -GPOALO-(GPO) 4 to 1.03 Å resolution in two crystal forms. In these structures, the interruption zone brings localized disruptions to the triple helix and introduces a light 6-8° bend with the same directional preference to the whole molecule, which may correspond structurally to the first physiological kink site in type XIX collagen. Furthermore, at the G5G interruption site, the presence of Ala and Leu residues, both with free N-H groups, allows the formation of more direct and water-mediated interchain hydrogen bonds than in the related Gly → Ala structure. These could partly explain the difference in thermal stability between the different interruptions. In addition, our structures provide a detailed view of the dynamic property of such an interrupted zone with respect to hydrogen bonding topology, torsion angles, and helical parameters. Our results, for the first time, also identified the binding of zinc to the end of the triple helix. These findings will shed light on how the interruption sequence influences the conformation of the collagen molecule and provide a structural basis for further functional studies.
Checklist interruption and resumption: A linguistic study
NASA Technical Reports Server (NTRS)
Linde, Charlotte; Goguen, Joseph
1987-01-01
This study forms part of a project investigating the relationships among the formal structure of aviation procedures, the ways in which the crew members are taught to execute them, and the ways in which thet are actually performed in flight. Specifically, this report examines the interactions between the performance of checklists and interruptions, considering both interruptions by radio communications and by other crew members. The data consists of 14 crews' performance of a full mission simulation of a higher ratio of checklist speech acts to all speech acts within the span of the performance of the checklist. Further, it is not number of interruptions but length of interruptions which is associated with crew performance quality. Use of explicit holds is also associated with crew performance.
Career Interruptions and Subsequent Earnings: A Reexamination Using Swedish Data.
ERIC Educational Resources Information Center
Albrecht, James W.; Edin, Per-Anders; Sundstrom, Marianne; Vroman, Susan B.
1999-01-01
Cross-sectional and panel estimations of Swedish data reveal that different types of career interruptions have different effects on wages, varying by gender. Therefore, human capital depreciation does not entirely account for the negative effect of career interruptions on subsequent wages. (SK)
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Mechanical interruption summary report. 135... Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... unscheduled stop or diversion from a route, caused by known or suspected mechanical difficulties or...
Polosky, Marc A.; Garcia, Ernest J.; Plummer, David W.
2001-01-01
A microminiature timer having an optical readout is disclosed. The timer can be formed by surface micromachining or LIGA processes on a silicon substrate. The timer includes an integral motor (e.g. an electrostatic motor) that can intermittently wind a mainspring to store mechanical energy for driving a train of meshed timing gears at a rate that is regulated by a verge escapement. Each timing gear contains an optical encoder that can be read out with one or more light beams (e.g. from a laser or light-emitting diode) to recover timing information. In the event that electrical power to the timer is temporarily interrupted, the mechanical clock formed by the meshed timing gears and verge escapement can continue to operate, generating accurate timing information that can be read out when the power is restored.
Satellite control of electric power distribution
NASA Technical Reports Server (NTRS)
Bergen, L.
1981-01-01
An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.
NASA Technical Reports Server (NTRS)
Kassel, P. C., Jr.
1978-01-01
A fail safe light activated switch was used as an emergency control link at the Langley Vortex Research Facility. In this facility aircraft models were towed through a still air test chamber by a gasoline powered vehicle which was launched from one end of a 427-meter track and attained velocities to 31 m/sec in the test chamber. A 5 mW HeNe laser with a mechanical copper provided a connecting link with the moving tow vehicle on which a silicon photodiode receiver with a specially designed amplifier provided a fail safe switching action. This system provided an emergency means of stopping the vehicle by turning off the laser to interrupt the power to the vehicle ignition and brake release systems.
NASA Astrophysics Data System (ADS)
Niwa, Yoshimitsu; Matsuzaki, Jun; Yokokura, Kunio
The high-speed vacuum circuit breaker, which forced the fault current to zero was investigated. The test circuit breaker consisted of a vacuum interrupter and a high frequency current source. The vacuum interrupter, which had the axial magnetic field electrode and the disk shape electrode, was tested. The arcing period of the high-speed vacuum circuit breaker is much shorter than that of conventional circuit breaker. The arc behavior of the test electrodes immediately after the contact separation was observed by a high-speed video camcorder. The relation between the current waveform just before the current zero and the interruption ability by varying the high frequency current source was investigated experimentally. The results demonstrate the interruption ability and the arc behavior of the high-speed vacuum circuit breaker. The high current interruption was made possible by the low current period just before the current zero, although the arcing time is short and the arc is concentrated.
Morgan, Phillip L; Patrick, John; Waldron, Samuel M; King, Sophia L; Patrick, Tanya
2009-12-01
Forgetting what one was doing prior to interruption is an everyday problem. The recent soft constraints hypothesis (Gray, Sims, Fu, & Schoelles, 2006) emphasizes the strategic adaptation of information processing strategy to the task environment. It predicts that increasing information access cost (IAC: the time, and physical and mental effort involved in accessing information) encourages a more memory-intensive strategy. Like interruptions, access costs are also intrinsic to most work environments, such as when opening documents and e-mails. Three experiments investigated whether increasing IAC during a simple copying task can be an effective method for reducing forgetting following interruption. IAC was designated Low (all information permanently visible), Medium (a mouse movement to uncover target information), or High (an additional few seconds to uncover such information). Experiment 1 found that recall improved across all three levels of IAC. Subsequent experiments found that High IAC facilitated resumption after interruption, particularly when interruption occurred on half of all trials (Experiment 2), and improved prospective memory following two different interrupting tasks, even when one involved the disruptive effect of using the same type of resource as the primary task (Experiment 3). The improvement of memory after interruption with increased IAC supports the prediction of the soft constraints hypothesis. The main disadvantage of a high access cost was a reduction in speed of task completion. The practicality of manipulating IAC as a design method for inducing a memory-intensive strategy to protect against forgetting is discussed. Copyright 2009 APA
Active distribution network planning considering linearized system loss
NASA Astrophysics Data System (ADS)
Li, Xiao; Wang, Mingqiang; Xu, Hao
2018-02-01
In this paper, various distribution network planning techniques with DGs are reviewed, and a new distribution network planning method is proposed. It assumes that the location of DGs and the topology of the network are fixed. The proposed model optimizes the capacities of DG and the optimal distribution line capacity simultaneously by a cost/benefit analysis and the benefit is quantified by the reduction of the expected interruption cost. Besides, the network loss is explicitly analyzed in the paper. For simplicity, the network loss is appropriately simplified as a quadratic function of difference of voltage phase angle. Then it is further piecewise linearized. In this paper, a piecewise linearization technique with different segment lengths is proposed. To validate its effectiveness and superiority, the proposed distribution network planning model with elaborate linearization technique is tested on the IEEE 33-bus distribution network system.
Network acceleration techniques
NASA Technical Reports Server (NTRS)
Crowley, Patricia (Inventor); Maccabe, Arthur Barney (Inventor); Awrach, James Michael (Inventor)
2012-01-01
Splintered offloading techniques with receive batch processing are described for network acceleration. Such techniques offload specific functionality to a NIC while maintaining the bulk of the protocol processing in the host operating system ("OS"). The resulting protocol implementation allows the application to bypass the protocol processing of the received data. Such can be accomplished this by moving data from the NIC directly to the application through direct memory access ("DMA") and batch processing the receive headers in the host OS when the host OS is interrupted to perform other work. Batch processing receive headers allows the data path to be separated from the control path. Unlike operating system bypass, however, the operating system still fully manages the network resource and has relevant feedback about traffic and flows. Embodiments of the present disclosure can therefore address the challenges of networks with extreme bandwidth delay products (BWDP).
Interrupted Visual Searches Reveal Volatile Search Memory
ERIC Educational Resources Information Center
Shen, Y. Jeremy; Jiang, Yuhong V.
2006-01-01
This study investigated memory from interrupted visual searches. Participants conducted a change detection search task on polygons overlaid on scenes. Search was interrupted by various disruptions, including unfilled delay, passive viewing of other scenes, and additional search on new displays. Results showed that performance was unaffected by…
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false CAMP: Mechanical interruption summary... Ownership Operations Program Management § 91.1417 CAMP: Mechanical interruption summary report. Each program... route, caused by known or suspected mechanical difficulties or malfunctions that are not required to be...
Stuart, Andrew; Butler, Alyson K
2012-10-01
One purported role of the medial olivocochlear (MOC) efferent system is to reduce the effects of masking noise. MOC system functioning can be evaluated noninvasively in humans through contralateral suppression of otoacoustic emissions. It has been suggested that the strength of the MOC efferent activity should be positively associated with listening performance in noise. The objective of the study was to further explore this notion by examining contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) and sentence recognition in two noises with normal hearing young adults. A repeated measures multivariate quasi-experimental design was employed. Thirty-two normal hearing young adult females participated. Reception thresholds for sentences (RTSs) were determined monaurally and binaurally in quiet and in competing continuous and interrupted noises. Both noises had an identical power spectrum and differed only in their temporal continuity. "Release from masking" was computed by subtracting RTS signal-to-noise ratios in interrupted from continuous noise. TEOAEs were evoked with 80 dB peSPL click stimuli. To examine contralateral suppression, TEOAEs were evaluated with 60 dB peSPL click stimuli with and without a contralateral 65 dB SPL white noise suppressor. A binaural advantage was observed for RTSs in quiet and noise (p < .0001) while there was no difference between ears (p >.05). In noise, performance was superior in the interrupted noise (i.e., RTSs were lower vs. continuous noise; p < .0001). There were no statistically significant differences in TEOAE levels between ears (p >.05). There was also no significant difference in the amount of suppression between ears (p = .41). There were no significant correlations or predictive linear relations between the amount of TEOAE suppression and any indices of sentence recognition in noise (i.e., RTS signal-to-noise ratios and release from masking; p > .05). The findings are not consistent with the notion that increased medial olivocochlear efferent feedback, as assessed via contralateral suppression of TEOAEs, is associated with improved speech perception in continuous and interrupted noise. American Academy of Audiology.
76 FR 27637 - Supplemental Priorities for Discretionary Grant Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-12
.... Interrupted time series design means a type of quasi-experimental study (as defined in this notice) in which... design is an adaptation of an interrupted time series design that relies on the comparison of treatment... notice), interrupted time series designs (as defined in this notice), or regression discontinuity designs...
75 FR 47284 - Secretary's Priorities for Discretionary Grant Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... the most currently available data. Interrupted time series design \\4\\ means a type of quasi... findings. \\4\\ A single subject or single case design is an adaptation of an interrupted time series design...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-739] Certain Ground Fault Circuit... importation of certain ground fault circuit interrupters and products containing the same by reason of... entry of ground fault circuit interrupters and products containing the same that infringe one or more of...
The Interrupted Intercourse in the Election Communication: Pragmatic Aspect
ERIC Educational Resources Information Center
Andryuchshenko, Olga K.; Suyunova, Gulnara S.; Nygmetova, Bibigul Dz.; Garanina, Ekaterina P.
2016-01-01
The article provides analysis of the interrupted communication as part of the communication in the election discourse. The authors explored the most typical reasons for the interrupted communication in the electoral discourse analyzed communication failures as a kind of ineffective communication. Communication failures are presented as a result of…
Interruption of a dry-type transformer in no-load by a vacuum circuit-breaker
NASA Astrophysics Data System (ADS)
Vandenheuvel, W. M. C.; Daalder, J. E.; Boone, M. J. M.; Wilmes, L. A. H.
1983-08-01
Overvoltages generated during interruption of a dry type delta-star connected transformer in no load by a vacuum breaker were studied. During interruption of inrush current 37% of the phase-to-ground overvoltages were 5 pu, and 6% 7 pu. Comparison of experimental and theoretical results using Boyle's model shows no discrepancy for inrush currents and clean overvoltages from the steady-state interruption. Overvoltages due to repetitive reignitions (not covered by Boyle's model) are higher than the calculated values during steady-state switching.
Microelectromechanical safe arm device
Roesler, Alexander W [Tijeras, NM
2012-06-05
Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.
Suicide Risk Characteristics among Aborted, Interrupted, and Actual Suicide Attempters
Burke, Taylor A.; Hamilton, Jessica L.; Ammerman, Brooke A.; Stange, Jonathan P.; Alloy, Lauren B.
2017-01-01
Few studies have investigated suicide risk characteristics associated with interrupted and aborted suicide attempts. The present study aimed to empirically examine whether assessing a history of interrupted and aborted suicide attempts is valuable when assessing suicide risk, given the relative lack of literature in this area to date. To inform this question, the current study examined differences in risk factors for suicidal behavior among individuals who have carried out a suicide attempt, individuals who report having a history of only interrupted and/or aborted suicide attempts, and non-attempter controls. Approximately 447 undergraduates (M = 21.10 years; SD = 4.16; 77.6% female) completed measures of carried out suicide attempts, interrupted suicide attempts, aborted suicide attempts, acquired capability for suicide, suicide likelihood, depressive symptoms, suicidal ideation, and non-suicidal self-injury. Results suggest that a faction of individuals endorse interrupted and/or aborted suicide attempts (8.7%), but do not endorse carried out suicide attempts, even in non-clinical samples. Furthermore, results suggest that there are few clinically meaningful differences between those with a history of carried out suicide attempts and interrupted/aborted suicide attempts, suggesting that individuals with a history of these lesser studied suicidal behaviors are an important group to target for suicide risk intervention. PMID:27344029
Bolwell, C F; Rogers, C W; French, N P; Firth, E C
2013-02-01
Few studies have investigated the effect of having interruptions during training on future training and racing performance in Thoroughbred racehorses. The aim of this paper was to investigate the effect of having an interruption before the first trial on starting in a trial or a race. A prospective cohort study was used to record the training activity of a cohort of Thoroughbred racehorses, over two racing seasons. Fourteen racehorse trainers recorded information on the distances worked at canter and at fast speeds (<15s/200 m) and provided reasons for horses not training, or for having interruptions (break from training). Trial and racing results were obtained from the New Zealand Thoroughbred Racing online database. A Cox proportional hazards regression model was used to investigate two outcome measures of performance: (1) time to the first trial and (2) time to the first race. The type of interruption that had occurred before the first trial was the main exposure of interest, and was grouped into: no interruption, voluntary (no known condition or disease present) and involuntary interruptions (due to the presence of a condition or disease). A total of 160/200 (80%) horses started in at least one trial and 100/205 (48%) horses started in at least one race during the study period. The median time to starting in a trial or a race differed significantly (p<0.001) with the type of interruption. The hazard of starting in a trial was lower for horses experiencing voluntary and involuntary interruptions (p<0.001) but there was no association with starting in a race, after adjusting for confounding variables. As age at the start of training increased the hazard of starting in a trial decreased. Horses accumulating longer distances at 15s/200 m had a higher hazard of starting in a trial, whilst horses accumulating fewer events at high speed and fewer trials had a reduced hazard of starting in a race. There was significant clustering at the trainer level for both the outcomes investigated. Interruptions to training had an effect on the time to, and hazard of, a trial but not a race start. The timing of these interruptions may have implications for future racing success and career longevity. Copyright © 2012 Elsevier B.V. All rights reserved.
Upright and Inverted Single-Junction GaAs Solar Cells Grown by Hydride Vapor Phase Epitaxy
Simon, John; Schulte, Kevin L.; Jain, Nikhil; ...
2016-10-19
Hydride vapor phase epitaxy (HVPE) is a low-cost alternative to conventional metal-organic vapor phase epitaxy (MOVPE) growth of III-V solar cells. In this work, we show continued improvement of the performance of HVPE-grown single-junction GaAs solar cells. We show over an order of magnitude improvement in the interface recombination velocity between GaAs and GaInP layers through the elimination of growth interrupts, leading to increased short-circuit current density and open-circuit voltage compared with cells with interrupts. One-sun conversion efficiencies as high as 20.6% were achieved with this improved growth process. Solar cells grown in an inverted configuration that were removed frommore » the substrate showed nearly identical performance to on-wafer cells, demonstrating the viability of HVPE to be used together with conventional wafer reuse techniques for further cost reduction. As a result, these devices utilized multiple heterointerfaces, showing the potential of HVPE for the growth of complex and high-quality III-V devices.« less
[Effects of bkdAB interruption on avermectin biosynthesis].
Zhu, Hao-Jun; Liang, Yun-Xiang; Zhou, Jun-Chu; Zheng, Ying-Hua
2004-03-01
In this study, Streptomyces avermitilis Bjbm0006 which produces four avermectin B components was used as an original test strain. A replacement plasmid containing a gene cluster bkdAB (branched-chain alpha-keto acid dehydrogenase gene) involved in the biosynthesis of avermectin B in S. avermitilis Bjbm0006 was constructed by means of PCR technique and then named as pHJ5821 (pHZ1358::bkdAB&erm). A recombinant strain Bjbm5821 was obtained after the gene cluster was interrupted by double crossover. This strain was tested in laboratory conditions and analysed by PCR using the total DNA as template. The HPLC analysis showed that the strain Bjbm5821 synthesized the same 'a' components Bla and B2a as the original strain did. However, It lost the ability for the production of 'b'components for example B1b and B2b. A novel compound was detected in fermentation products. The results of present study suggests that the production of gene cluster bkdAB may play a main role similar to alpha-ketoisovaleric acid dehydrogenase in the pathway of avermectin synthesis.
High speed photodiodes in standard nanometer scale CMOS technology: a comparative study.
Nakhkoob, Behrooz; Ray, Sagar; Hella, Mona M
2012-05-07
This paper compares various techniques for improving the frequency response of silicon photodiodes fabricated in mainstream CMOS technology for fully integrated optical receivers. The three presented photodiodes, Spatially Modulated Light detectors, Double, and Interrupted P-Finger photodiodes, aim at reducing the low speed diffusive component of the photo generated current. For the first photodiode, Spatially Modulated Light (SML) detectors, the low speed current component is canceled out by converting it to a common mode current driving a differential transimpedance amplifier. The Double Photodiode (DP) uses two depletion regions to increase the fast drift component, while the Interrupted-P Finger Photodiode (IPFPD) redirects the low speed component towards a different contact from the main fast terminal of the photodiode. Extensive device simulations using 130 nm CMOS technology-parameters are presented to compare their performance using the same technological platform. Finally a new type of photodiode that uses triple well CMOS technology is introduced that can achieve a bandwidth of roughly 10 GHz without any process modification or high reverse bias voltages that would jeopardize the photodetector and subsequent transimpedance amplifier reliability.
PCIE interface design for high-speed image storage system based on SSD
NASA Astrophysics Data System (ADS)
Wang, Shiming
2015-02-01
This paper proposes and implements a standard interface of miniaturized high-speed image storage system, which combines PowerPC with FPGA and utilizes PCIE bus as the high speed switching channel. Attached to the PowerPC, mSATA interface SSD(Solid State Drive) realizes RAID3 array storage. At the same time, a high-speed real-time image compression patent IP core also can be embedded in FPGA, which is in the leading domestic level with compression rate and image quality, making that the system can record higher image data rate or achieve longer recording time. The notebook memory card buckle type design is used in the mSATA interface SSD, which make it possible to complete the replacement in 5 seconds just using single hand, thus the total length of repeated recordings is increased. MSI (Message Signaled Interrupts) interruption guarantees the stability and reliability of continuous DMA transmission. Furthermore, only through the gigabit network, the remote display, control and upload to backup function can be realized. According to an optional 25 frame/s or 30 frame/s, upload speeds can be up to more than 84 MB/s. Compared with the existing FLASH array high-speed memory systems, it has higher degree of modularity, better stability and higher efficiency on development, maintenance and upgrading. Its data access rate is up to 300MB/s, realizing the high speed image storage system miniaturization, standardization and modularization, thus it is fit for image acquisition, storage and real-time transmission to server on mobile equipment.
Westbrook, Johanna I; Raban, Magdalena Z; Walter, Scott R; Douglas, Heather
2018-01-09
Interruptions and multitasking have been demonstrated in experimental studies to reduce individuals' task performance. These behaviours are frequently used by clinicians in high-workload, dynamic clinical environments, yet their effects have rarely been studied. To assess the relative contributions of interruptions and multitasking by emergency physicians to prescribing errors. 36 emergency physicians were shadowed over 120 hours. All tasks, interruptions and instances of multitasking were recorded. Physicians' working memory capacity (WMC) and preference for multitasking were assessed using the Operation Span Task (OSPAN) and Inventory of Polychronic Values. Following observation, physicians were asked about their sleep in the previous 24 hours. Prescribing errors were used as a measure of task performance. We performed multivariate analysis of prescribing error rates to determine associations with interruptions and multitasking, also considering physician seniority, age, psychometric measures, workload and sleep. Physicians experienced 7.9 interruptions/hour. 28 clinicians were observed prescribing 239 medication orders which contained 208 prescribing errors. While prescribing, clinicians were interrupted 9.4 times/hour. Error rates increased significantly if physicians were interrupted (rate ratio (RR) 2.82; 95% CI 1.23 to 6.49) or multitasked (RR 1.86; 95% CI 1.35 to 2.56) while prescribing. Having below-average sleep showed a >15-fold increase in clinical error rate (RR 16.44; 95% CI 4.84 to 55.81). WMC was protective against errors; for every 10-point increase on the 75-point OSPAN, a 19% decrease in prescribing errors was observed. There was no effect of polychronicity, workload, physician gender or above-average sleep on error rates. Interruptions, multitasking and poor sleep were associated with significantly increased rates of prescribing errors among emergency physicians. WMC mitigated the negative influence of these factors to an extent. These results confirm experimental findings in other fields and raise questions about the acceptability of the high rates of multitasking and interruption in clinical environments. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
PolyQ repeat expansions in ATXN2 associated with ALS are CAA interrupted repeats.
Yu, Zhenming; Zhu, Yongqing; Chen-Plotkin, Alice S; Clay-Falcone, Dana; McCluskey, Leo; Elman, Lauren; Kalb, Robert G; Trojanowski, John Q; Lee, Virginia M-Y; Van Deerlin, Vivianna M; Gitler, Aaron D; Bonini, Nancy M
2011-03-29
Amyotrophic lateral sclerosis (ALS) is a devastating, rapidly progressive disease leading to paralysis and death. Recently, intermediate length polyglutamine (polyQ) repeats of 27-33 in ATAXIN-2 (ATXN2), encoding the ATXN2 protein, were found to increase risk for ALS. In ATXN2, polyQ expansions of ≥ 34, which are pure CAG repeat expansions, cause spinocerebellar ataxia type 2. However, similar length expansions that are interrupted with other codons, can present atypically with parkinsonism, suggesting that configuration of the repeat sequence plays an important role in disease manifestation in ATXN2 polyQ expansion diseases. Here we determined whether the expansions in ATXN2 associated with ALS were pure or interrupted CAG repeats, and defined single nucleotide polymorphisms (SNPs) rs695871 and rs695872 in exon 1 of the gene, to assess haplotype association. We found that the expanded repeat alleles of 40 ALS patients and 9 long-repeat length controls were all interrupted, bearing 1-3 CAA codons within the CAG repeat. 21/21 expanded ALS chromosomes with 3CAA interruptions arose from one haplotype (GT), while 18/19 expanded ALS chromosomes with <3CAA interruptions arose from a different haplotype (CC). Moreover, age of disease onset was significantly earlier in patients bearing 3 interruptions vs fewer, and was distinct between haplotypes. These results indicate that CAG repeat expansions in ATXN2 associated with ALS are uniformly interrupted repeats and that the nature of the repeat sequence and haplotype, as well as length of polyQ repeat, may play a role in the neurological effect conferred by expansions in ATXN2.
Belcher, Britni R; Berrigan, David; Papachristopoulou, Alexia; Brady, Sheila M; Bernstein, Shanna B; Brychta, Robert J; Hattenbach, Jacob D; Tigner, Ira L; Courville, Amber B; Drinkard, Bart E; Smith, Kevin P; Rosing, Douglas R; Wolters, Pamela L; Chen, Kong Y; Yanovski, Jack A
2015-10-01
Limited data suggest that interrupting sedentary behaviors with activity improves metabolic parameters in adults. We tested whether interrupting sitting with short, moderate-intensity walking bouts improved glucose tolerance in children. Participants underwent two experimental conditions in random order on different days: continuous sitting for 3 hours or sitting interrupted by walking (3 min of moderate-intensity walking every 30 min). Insulin, C-peptide, glucose, and free fatty acids were measured every 30 minutes for 3 hours during an oral glucose tolerance test. Area under the curve (AUC) was calculated from hormone and substrate measurements. Children were given a buffet meal after each condition. The study was conducted at the National Institutes of Health Hatfield Clinical Research Center. Twenty-eight normal-weight 7-11 year olds participated. Patterns of substrate/hormone secretion and AUC, as well as energy intake, were examined by experimental condition. Interrupting sitting resulted in a 32% lower insulin AUC (P < .001), 17% lower C-peptide AUC (P < .001), and 7% lower glucose AUC (P = .018) vs continuous sitting. Mixed model results indicated that insulin (P = .036) and free fatty acid concentrations (P = .009) were significantly lower in the interrupted vs the continuous sitting condition. Lunchtime buffet meal energy intake did not significantly differ between the conditions (975 ± 387 vs 963 ± 309 kcal; P = .85). Interrupting sedentary time with brief moderate-intensity walking improved short-term metabolic function in non-overweight children without increasing subsequent energy intake. These findings suggest that interrupting sedentary behavior may be a promising prevention strategy for reducing cardiometabolic risk in children.
Interruptions disrupt reading comprehension.
Foroughi, Cyrus K; Werner, Nicole E; Barragán, Daniela; Boehm-Davis, Deborah A
2015-06-01
Previous research suggests that being interrupted while reading a text does not disrupt the later recognition or recall of information from that text. This research is used as support for Ericsson and Kintsch's (1995) long-term working memory (LT-WM) theory, which posits that disruptions while reading (e.g., interruptions) do not impair subsequent text comprehension. However, to fully comprehend a text, individuals may need to do more than recognize or recall information that has been presented in the text at a later time. Reading comprehension often requires individuals to connect and synthesize information across a text (e.g., successfully identifying complex topics such as themes and tones) and not just make a familiarity-based decision (i.e., recognition). The goal for this study was to determine whether interruptions while reading disrupt reading comprehension when the questions assessing comprehension require participants to connect and synthesize information across the passage. In Experiment 1, interruptions disrupted reading comprehension. In Experiment 2, interruptions disrupted reading comprehension but not recognition of information from the text. In Experiment 3, the addition of a 15-s time-out prior to the interruption successfully removed these negative effects. These data suggest that the time it takes to process the information needed to successfully comprehend text when reading is greater than that required for recognition. Any interference (e.g., an interruption) that occurs during the comprehension process may disrupt reading comprehension. This evidence supports the need for transient activation of information in working memory for successful text comprehension and does not support LT-WM theory. (c) 2015 APA, all rights reserved).
Bonneville, Power Administration Timing System
NASA Technical Reports Server (NTRS)
Martin, Kenneth E.
1996-01-01
Time is an integral part of the Bonneville Power Administration's (BPA) operational systems. Generation and power transfers are planned in advance. Utilities coordinate with each other by making these adjustments on a timed schedule. Price varies with demand, so billing is based on time. Outages for maintenance are scheduled to assure they do not interrupt reliable power delivery. Disturbance records are aligned with recorded timetags for analysis and comparison with related information. Advanced applications like traveling wave fault location and real-time phase measurement require continuous timing with high precision. Most of BPA is served by a Central Time System (CTS) at the Dittmer Control Center near Portland, OR. This system keeps time locally and supplies time to both the control center systems and field locations via a microwave signal. It is kept synchronized to national standard time and coordinated with interconnected utilities. It is the official BPA time. Powwer system control and operation is described, followed by a description of BPA timing systems including CTS, the Fault Location Acquisition Reporter, time dissemination, and phasor measurements. References are provided for further reading.
Fritts, T.H.
2002-01-01
The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978–1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M $4.5M"> per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.
Design mechanic generator under speed bumper to support electricity recourse for urban traffic light
NASA Astrophysics Data System (ADS)
Sabri, M.; Lauzuardy, Jason; Syam, Bustami
2018-03-01
The electrical energy needs for the traffic lights in some cities of developing countries cannot be achieved continuously due to limited capacity and interruption of electricity distribution, the main power plant. This issues can lead to congestion at the crossroads. To overcome the problem of street chaos due to power failure, we can cultivate to provide electrical energy from other sources such as using the bumper to generate kinetic energy, which can be converted into electrical energy. This study designed a generator mechanic that will be mounted on the bumper construction to generate electricity for the purposes of traffic lights at the crossroads. The Mechanical generator is composed of springs, levers, sprockets, chains, flywheel and customize power generator. Through the rotation of the flywheel, we can earned 9 Volt DC voltage and electrical current of 5.89 Ampere. This achievement can be used to charge the accumulator which can be used to power the traffic lights, and to charge the accumulator capacity of 6 Ah, the generator works in the charging time for 1.01 hours.
The European Alps as an interrupter of the Earth's conductivity structures
NASA Astrophysics Data System (ADS)
Al-Halbouni, D.
2013-07-01
Joint interpretation of magnetotelluric and geomagnetic depth sounding results in the period range of 10-105 s in the Western European Alps offer new insights into the conductivity structure of the Earth's crust and mantle. This first large scale electromagnetic study in the Alps covers a cross-section from Germany to northern Italy and shows the importance of the alpine mountain chain as an interrupter of continuous conductors. Poor data quality due to the highly crystalline underground is overcome by Remote Reference and Robust Processing techniques and the combination of both electromagnetic methods. 3-D forward modeling reveals on the one hand interrupted dipping crustal conductors with maximum conductances of 4960 S and on the other hand a lithosphere thickening up to 208 km beneath the central Western Alps. Graphite networks arising from Palaeozoic sedimentary deposits are considered to be accountable for the occurrence of high conductivity and the distribution pattern of crustal conductors. The influence of huge sedimentary Molasse basins on the electromagnetic data is suggested to be minor compared with the influence of crustal conductors. Dipping direction (S-SE) and maximum angle (10.1°) of the northern crustal conductor reveal the main thrusting conditions beneath the Helvetic Alps whereas the existence of a crustal conductor in the Briançonnais supports theses about its belonging to the Iberian Peninsula. In conclusion the proposed model arisen from combined 3-D modeling of noise corrected electromagnetic data is able to explain the geophysical influence of various structural features in and around the Western European Alps and serves as a background for further upcoming studies.
77 FR 18229 - Applications for New Awards; Investing in Innovation Fund, Validation Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-27
... the appearance of a conflict of interest. Interrupted time series design \\8\\ means a type of quasi... single case design is an adaptation of an interrupted time series design that relies on the comparison of... notice), interrupted time series designs (as defined in this notice), or regression discontinuity designs...
76 FR 32148 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
.... Interrupted time series design \\5\\ means a type of quasi- experimental study in which the outcome of interest... interrupted time series design that relies on the comparison of treatment effects on a single subject or group... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined...
77 FR 18216 - Applications for New Awards; Investing in Innovation Fund, Scale-Up Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-27
... evaluation and prevents even the appearance of a conflict of interest. Interrupted time series design \\8... findings. \\8\\ A single subject or single case design is an adaptation of an interrupted time series design... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined...
76 FR 32171 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... conflict of interest. Interrupted time series design \\5\\ means a type of quasi- experimental study in... single case design is an adaptation of an interrupted time series design that relies on the comparison of...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
76 FR 32159 - Applications for New Awards; Investing in Innovation Fund
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... conflict of interest. Interrupted time series design \\5\\ means a type of quasi- experimental study in which... design is an adaptation of an interrupted time series design that relies on the comparison of treatment...), interrupted time series designs (as defined in this notice), or regression discontinuity designs (as defined...
Interruptions and Failure in Higher Education: Evidence from ISEG-UTL
ERIC Educational Resources Information Center
Chagas, Margarida; Fernandaes, Graca Leao
2011-01-01
Failure in higher education (HE) is the outcome of multiple time-dependent determinants. Interruptions in students' individual school trajectories are one of them, and that is why research on this topic has been attracting much attention these days. From an individual point of view, it is expected that interruptions in school trajectory, whatever…
Low latency counter event indication
Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY
2008-09-16
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
Low latency counter event indication
Gara, Alan G.; Salapura, Valentina
2010-08-24
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
Preventing messaging queue deadlocks in a DMA environment
Blocksome, Michael A; Chen, Dong; Gooding, Thomas; Heidelberger, Philip; Parker, Jeff
2014-01-14
Embodiments of the invention may be used to manage message queues in a parallel computing environment to prevent message queue deadlock. A direct memory access controller of a compute node may determine when a messaging queue is full. In response, the DMA may generate and interrupt. An interrupt handler may stop the DMA and swap all descriptors from the full messaging queue into a larger queue (or enlarge the original queue). The interrupt handler then restarts the DMA. Alternatively, the interrupt handler stops the DMA, allocates a memory block to hold queue data, and then moves descriptors from the full messaging queue into the allocated memory block. The interrupt handler then restarts the DMA. During a normal messaging advance cycle, a messaging manager attempts to inject the descriptors in the memory block into other messaging queues until the descriptors have all been processed.
Danilov, Nikolay; Lyagaeva, Julia; Vdovin, Gennady; Medvedev, Dmitry; Demin, Anatoly; Tsiakaras, Panagiotis
2017-08-16
The design and development of highly conductive materials with wide electrolytic domain boundaries are among the most promising means of enabling solid oxide fuel cells (SOFCs) to demonstrate outstanding performance across low- and intermediate-temperature ranges. While reducing the thickness of the electrolyte is an extensively studied means for diminishing the total resistance of SOFCs, approaches involving an improvement in the transport behavior of the electrolyte membranes have been less-investigated. In the present work, a strategy for analyzing the electrolyte properties and their effect on SOFC output characteristics is proposed. To this purpose, a SOFC based on a recently developed BaCe 0.5 Zr 0.3 Dy 0.2 O 3-δ proton-conducting ceramic material was fabricated and tested. The basis of the strategy consists of the use of traditional SOFC testing techniques combined with the current interruption method and electromotive force measurements with a modified polarization-correction assessment. This allows one to determine simultaneously such important parameters as maximal power density; ohmic and polarization resistances; average ion transport numbers; and total, ionic, and electronic film conductivities and their activation energies. The proposed experimental procedure is expected to expand both fundamental and applied basics that could be further adopted to improve the technology of electrochemical devices based on proton-conducting electrolytes.
Solvoll, Terje; Scholl, Jeremiah; Hartvigsen, Gunnar
2013-03-07
A common denominator of modern hospitals is a variety of communication problems. In particular, interruptions from mobile communication devices are a cause of great concern for many physicians. To characterize how interruptions from mobile devices disturb physicians in their daily work. The gathered knowledge will be subsequently used as input for the design and development of a context-sensitive communication system for mobile communications suitable for hospitals. This study adheres to an ethnographic and interpretive field research approach. The data gathering consisted of participant observations, non-structured and mostly ad hoc interviews, and open-ended discussions with a selected group of physicians. Eleven physicians were observed for a total of 135 hours during May and June 2009. The study demonstrates to what degree physicians are interrupted by mobile devices in their daily work and in which situations they are interrupted, such as surgery, examinations, and during patients/relatives high-importance level conversations. The participants in the study expected, and also indicated, that wireless phones probably led to more interruptions immediately after their introduction in a clinic, when compared to a pager, but this changed after a short while. The unpleasant feeling experienced by the caller when interrupting someone by calling them differs compared to sending a page message, which leaves it up to the receiver when to return the call. Mobile devices, which frequently interrupt physicians in hospitals, are a problem for both physicians and patients. The results from this study contribute to knowledge being used as input for designing and developing a prototype for a context-sensitive communication system for mobile communication suitable for hospitals. We combined these findings with results from earlier studies and also involved actual users to develop the prototype, CallMeSmart. This system intends to reduce such interruptions and at the same time minimize the number of communication devices needed per user.
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-11-01
Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Prakash, Varuna; Koczmara, Christine; Savage, Pamela; Trip, Katherine; Stewart, Janice; McCurdie, Tara; Cafazzo, Joseph A; Trbovich, Patricia
2014-01-01
Background Nurses are frequently interrupted during medication verification and administration; however, few interventions exist to mitigate resulting errors, and the impact of these interventions on medication safety is poorly understood. Objective The study objectives were to (A) assess the effects of interruptions on medication verification and administration errors, and (B) design and test the effectiveness of targeted interventions at reducing these errors. Methods The study focused on medication verification and administration in an ambulatory chemotherapy setting. A simulation laboratory experiment was conducted to determine interruption-related error rates during specific medication verification and administration tasks. Interventions to reduce these errors were developed through a participatory design process, and their error reduction effectiveness was assessed through a postintervention experiment. Results Significantly more nurses committed medication errors when interrupted than when uninterrupted. With use of interventions when interrupted, significantly fewer nurses made errors in verifying medication volumes contained in syringes (16/18; 89% preintervention error rate vs 11/19; 58% postintervention error rate; p=0.038; Fisher's exact test) and programmed in ambulatory pumps (17/18; 94% preintervention vs 11/19; 58% postintervention; p=0.012). The rate of error commission significantly decreased with use of interventions when interrupted during intravenous push (16/18; 89% preintervention vs 6/19; 32% postintervention; p=0.017) and pump programming (7/18; 39% preintervention vs 1/19; 5% postintervention; p=0.017). No statistically significant differences were observed for other medication verification tasks. Conclusions Interruptions can lead to medication verification and administration errors. Interventions were highly effective at reducing unanticipated errors of commission in medication administration tasks, but showed mixed effectiveness at reducing predictable errors of detection in medication verification tasks. These findings can be generalised and adapted to mitigate interruption-related errors in other settings where medication verification and administration are required. PMID:24906806
SU-E-T-171: Missing Dose in Integrated EPID Images.
King, B; Seymour, E; Nitschke, K
2012-06-01
A dosimetric artifact has been observed with Varian EPIDs in the presence of beam interrupts. This work determines the root cause and significance of this artifact. Integrated mode EPID images were acquired both with and without a manual beam interrupt for rectangular, sliding gap IMRT fields. Simultaneously, the individual frames were captured on a separate computer using a frame-grabber system. Synchronization of the individual frames with the integrated images allowed the determination of precisely how the EPID behaved during regular operation as well as when a beam interrupt was triggered. The ability of the EPID to reliably monitor a treatment in the presence of beam interrupts was tested by comparing the difference between the interrupt and non-interrupt images. The interrupted images acquired in integrated acquisition mode displayed unanticipated behaviour in the region of the image where the leaves were located when the beam interrupt was triggered. Differences greater than 5% were observed as a result of the interrupt in some cases, with the discrepancies occurring in a non-uniform manner across the imager. The differences measured were not repeatable from one measurement to another. Examination of the individual frames showed that the EPID was consistently losing a small amount of dose at the termination of every exposure. Inclusion of one additional frame in every image rectified the unexpected behaviour, reducing the differences to 1% or less. Although integrated EPID images nominally capture the entire dose delivered during an exposure, a small amount of dose is consistently being lost at the end of every exposure. The amount of missing dose is random, depending on the exact beam termination time within a frame. Inclusion of an extra frame at the end of each exposure effectively rectifies the problem, making the EPID more suitable for clinical dosimetry applications. The authors received support from Varian Medical Systems in the form of software and equipment loans as well as technical support. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Syarip; Po, L. C. C.
2018-05-01
In planning for nuclear power plant construction in Indonesia, helium cooled high temperature reactor (HTR) is favorable for not relying upon water supply that might be interrupted by earthquake. In order to train its personnel, BATAN has cooperated with Micro-Simulation Technology of USA to develop a 200 MWt PC-based simulation model PCTRAN/HTR. It operates in Win10 environment with graphic user interface (GUI). Normal operation of startup, power maneuvering, shutdown and accidents including pipe breaks and complete loss of AC power have been conducted. A sample case of safety analysis simulation to demonstrate the inherent safety features of HTR was done for helium pipe break malfunction scenario. The analysis was done for the variation of primary coolant pipe break i.e. from 0,1% - 0,5 % and 1% - 10 % helium gas leakages, while the reactor was operated at the maximum constant power of 10 MWt. The result shows that the highest temperature of HTR fuel centerline and coolant were 1150 °C and 1296 °C respectively. With 10 kg/s of helium flow in the reactor core, the thermal power will back to the startup position after 1287 s of helium pipe break malfunction.
Basis for the power supply reliability study of the 1 MW neutron source
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGhee, D.G.; Fathizadeh, M.
1993-07-01
The Intense Pulsed Neutron Source (IPNS) upgrade to 1 MW requires new power supply designs. This paper describes the tools and the methodology needed to assess the reliability of the power supplies. Both the design and operation of the power supplies in the synchrotron will be taken into account. To develop a reliability budget, the experiments to be conducted with this accelerator are reviewed, and data is collected on the number and duration of interruptions possible before an experiment is required to start over. Once the budget is established, several accelerators of this type will be examined. The budget ismore » allocated to the different accelerator systems based on their operating experience. The accelerator data is usually in terms of machine availability and system down time. It takes into account mean time to failure (MTTF), time to diagnose, time to repair or replace the failed components, and time to get the machine back online. These estimated times are used as baselines for the design. Even though we are in the early stage of design, available data can be analyzed to estimate the MTTF for the power supplies.« less
Thrombus formation in the interrupted segment of the aorta.
Karavelioğlu, Yusuf; Kalçık, Macit; Yetim, Mucahit; Doğan, Tolga; Gölbaşı, Zehra
2017-06-01
Interrupted aorta is a very rare heart defect in which there is a gap between the ascending and the descending thoracic aorta. It is usually associated with other cardiac anomalies, including ventricular septal defect, ductus arteriosus, and truncus arteriosus. Severe cases present with serious complications such as hypertension, heart failure, or intracranial hemorrhage. Neurological complications are very rare form of presentation and commonly associated with intracranial aneurysms. We have reported a case of interrupted aorta who presented with transient ischemic attack due to thrombus formation in the interrupted segment of the aorta. © 2017, Wiley Periodicals, Inc.
Con Edison power failure of July 13 and 14, 1977. Final staff report
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1978-06-01
On July 13, 1977 the entire electric load of the Con Edison system was lost, plunging New York City and Westchester County into darkness. The collapse resulted from a combination of natural events, equipment malfunctions, questionable system-design features, and operating errors. An attempt is made in this report to answer the following: what were the specific causes of the failure; if equipment malfunctions and operator errors contributed, could they have been prevented; to what extent was Con Edison prepared to handle such an emergency; and did Con Edison plan prudently reserve generation, for reserve transmission capability, for automatic equipment tomore » protect its system, and for proper operator response to a critical situation. Following the introductory and summary section, additional sections include: the Consolidated Edison system; prevention of bulk power-supply interruptions; the sequence of failure and restoration; analysis of the July 1977 power failure; restoration sequence and equipment damage assessment; and other investigations of the blackout. (MCW)« less
Pulsed thermionic converter study
NASA Technical Reports Server (NTRS)
1976-01-01
A nuclear electric propulsion concept using a thermionic reactor inductively coupled to a magnetoplasmadynamic accelerator (MPD arc jet) is described, and the results of preliminary analyses are presented. In this system, the MPD thruster operates intermittently at higher voltages and power levels than the thermionic generating unit. A typical thrust pulse from the MPD arc jet is characterized by power levels of 1 to 4 MWe, a duration of 1 msec, and a duty cycle of approximately 20%. The thermionic generating unit operates continuously but with a lower power level of approximately 0.4 MWe. Energy storage between thrust pulses is provided by building up a large current in an inductor using the output of the thermionic converter array. Periodically, the charging current is interrupted, and the energy stored in the magnetic field of the inductor is utilized for a short duration thrust pulse. The results of the preliminary analysis show that a coupling effectiveness of approximately 85 to 90% is feasible for a nominal 400 KWe system with an inductive unit suitable for a flight vehicle.
Schneider, Ana Paula; Matte, Ursula; Pasqualim, Gabriela; Tavares, Angela Maria Vicente; Mayer, Fabiana Quoos; Martinelli, Barbara; Ribas, Graziela; Vargas, Carmen Regla; Giugliani, Roberto; Baldo, Guilherme
2016-10-01
Temporary interruption of enzyme replacement therapy (ERT) in patients with different lysosomal storage disorders may happen for different reasons (adverse reactions, issues with reimbursement, logistic difficulties, and so forth), and the impact of the interruption is still uncertain. In the present work, we studied the effects of the interruption of intravenous ERT (Laronidase, Genzyme) followed by its reintroduction in mice with the prototypical lysosomal storage disorder mucopolysaccharidosis type I, comparing to mice receiving continuous treatment, untreated mucopolysaccharidosis type I mice, and normal mice. In the animals which treatment was temporarily interrupted, we observed clear benefits of treatment in several organs (liver, lung, heart, kidney, and testis) after reintroduction, but a worsening in the thickness of the aortic wall was detected. Furthermore, these mice had just partial improvements in behavioral tests, suggesting some deterioration in the brain function. Despite worsening is some disease aspects, urinary glycosaminoglycans levels did not increase during interruption, which indicates that this biomarker commonly used to monitor treatment in patients should not be used alone to assess treatment efficacy. The deterioration observed was not caused by the development of serum antienzyme antibodies. All together our results suggest that temporary ERT interruption leads to deterioration of function in some organs and should be avoided whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Endo, M.; Hori, T.; Koyama, K.; Yamaguchi, I.; Arai, K.; Kaiho, K.; Yanabu, S.
2008-02-01
Using a high temperature superconductor, we constructed and tested a model Superconducting Fault Current Limiter (SFCL). SFCL which has a vacuum interrupter with electromagnetic repulsion mechanism. We set out to construct high voltage class SFCL. We produced the electromagnetic repulsion switch equipped with a 24kV vacuum interrupter(VI). There are problems that opening speed becomes late. Because the larger vacuum interrupter the heavier weight of its contact. For this reason, the current which flows in a superconductor may be unable to be interrupted within a half cycles of current. In order to solve this problem, it is necessary to change the design of the coil connected in parallel and to strengthen the electromagnetic repulsion force at the time of opening the vacuum interrupter. Then, the design of the coil was changed, and in order to examine whether the problem is solvable, the current limiting test was conducted. We examined current limiting test using 4 series and 2 parallel-connected YBCO thin films. We used 12-centimeter-long YBCO thin film. The parallel resistance (0.1Ω) is connected with each YBCO thin film. As a result, we succeed in interrupting the current of superconductor within a half cycle of it. Furthermore, series and parallel-connected YBCO thin film could limit without failure.
Middleton, Addie; Graham, James E.; Krishnan, Shilpa; Ottenbacher, Kenneth J.
2016-01-01
Objective To present comprehensive descriptive summaries of program interruptions and short-stay transfers among Medicare fee-for-service beneficiaries receiving inpatient rehabilitation following stroke, traumatic brain injury (TBI), and traumatic spinal cord injury (SCI). Design Retrospective cohort study of Medicare beneficiaries with any of the three conditions of interest who were admitted to inpatient rehabilitation directly from an acute hospital between July 1, 2012 and November 15, 2013. Results In the final sample (stroke: n=71 769; TBI: n=7109; SCI: n=659), program interruption rates were 0.9% (stroke), 0.8% (TBI), and 1.4% (SCI). Short-stay transfer rates were 22.3% (stroke), 21.8% (TBI), and 31.6% (SCI). 14.7% of short-stay transfers and 12.3% of interruptions resulting in a return to acute care were identified as potentially preventable among those with stroke, 10.2% of transfers and 11.7% of interruptions among those with TBI, and 3.8% of transfers and 11.1% of interruptions among those with SCI. Conclusions Broad healthcare policies aimed at improving quality and reducing costs are currently being implemented. Reducing program interruptions and short-stay transfers during inpatient rehabilitative care represents a potential target for care-improvement efforts. Future research focused on identifying modifiable risk factors for potentially undesirable outcomes will allow for targeted preventative interventions. PMID:27631389
Middleton, Addie; Graham, James E; Krishnan, Shilpa; Ottenbacher, Kenneth J
2016-11-01
The objective of this work was to present comprehensive descriptive summaries of program interruptions and short-stay transfers among Medicare fee-for-service beneficiaries receiving inpatient rehabilitation after stroke, traumatic brain injury (TBI), and traumatic spinal cord injury (SCI). Retrospective cohort study of Medicare beneficiaries with any of the 3 conditions of interest who were admitted to inpatient rehabilitation directly from an acute hospital between July 1, 2012, and November 15, 2013. In the final sample (stroke, n = 71 769; TBI, n = 7109; SCI, n = 659), program interruption rates were 0.9% (stroke), 0.8% (TBI), and 1.4% (SCI). Short-stay transfer rates were 22.3% (stroke), 21.8% (TBI), and 31.6% (SCI); 14.7% of short-stay transfers and 12.3% of interruptions resulting in a return to acute care were identified as potentially preventable among those with stroke; 10.2% of transfers and 11.7% of interruptions among those with TBI, and 3.8% of transfers and 11.1% of interruptions among those with SCI. Broad health care policies aimed at improving quality and reducing costs are currently being implemented. Reducing program interruptions and short-stay transfers during inpatient rehabilitative care represents a potential target for care-improvement efforts. Future research focused on identifying modifiable risk factors for potentially undesirable outcomes will allow for targeted preventative interventions.
Impact of Frequent Interruption on Nurses' Patient-Controlled Analgesia Programming Performance.
Campoe, Kristi R; Giuliano, Karen K
2017-12-01
The purpose was to add to the body of knowledge regarding the impact of interruption on acute care nurses' cognitive workload, total task completion times, nurse frustration, and medication administration error while programming a patient-controlled analgesia (PCA) pump. Data support that the severity of medication administration error increases with the number of interruptions, which is especially critical during the administration of high-risk medications. Bar code technology, interruption-free zones, and medication safety vests have been shown to decrease administration-related errors. However, there are few published data regarding the impact of number of interruptions on nurses' clinical performance during PCA programming. Nine acute care nurses completed three PCA pump programming tasks in a simulation laboratory. Programming tasks were completed under three conditions where the number of interruptions varied between two, four, and six. Outcome measures included cognitive workload (six NASA Task Load Index [NASA-TLX] subscales), total task completion time (seconds), nurse frustration (NASA-TLX Subscale 6), and PCA medication administration error (incorrect final programming). Increases in the number of interruptions were associated with significant increases in total task completion time ( p = .003). We also found increases in nurses' cognitive workload, nurse frustration, and PCA pump programming errors, but these increases were not statistically significant. Complex technology use permeates the acute care nursing practice environment. These results add new knowledge on nurses' clinical performance during PCA pump programming and high-risk medication administration.
Fogerty, Daniel
2011-01-01
Listeners often only have fragments of speech available to understand the intended message due to competing background noise. In order to maximize successful speech recognition, listeners must allocate their perceptual resources to the most informative acoustic properties. The speech signal contains temporally-varying acoustics in the envelope and fine structure that are present across the frequency spectrum. Understanding how listeners perceptually weigh these acoustic properties in different frequency regions during interrupted speech is essential for the design of assistive listening devices. This study measured the perceptual weighting of young normal-hearing listeners for the envelope and fine structure in each of three frequency bands for interrupted sentence materials. Perceptual weights were obtained during interruption at the syllabic rate (i.e., 4 Hz) and the periodic rate (i.e., 128 Hz) of speech. Potential interruption interactions with fundamental frequency information were investigated by shifting the natural pitch contour higher relative to the interruption rate. The availability of each acoustic property was varied independently by adding noise at different levels. Perceptual weights were determined by correlating a listener’s performance with the availability of each acoustic property on a trial-by-trial basis. Results demonstrated similar relative weights across the interruption conditions, with emphasis on the envelope in high-frequencies. PMID:21786914
ERIC Educational Resources Information Center
St. Clair, Travis; Hallberg, Kelly; Cook, Thomas D.
2014-01-01
Researchers are increasingly using comparative interrupted time series (CITS) designs to estimate the effects of programs and policies when randomized controlled trials are not feasible. In a simple interrupted time series design, researchers compare the pre-treatment values of a treatment group time series to post-treatment values in order to…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-04
... in the manufacture of the drug or an interruption in the manufacturing of the drug that is likely to... Manufacturing of Certain Drug or Biological Products AGENCY: Food and Drug Administration, HHS. ACTION: Proposed... permanent discontinuance or an interruption in manufacturing of the product that is likely to lead to a...
77 FR 11087 - Applications for New Awards; Investing in Innovation Fund, Development Grants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... prevents even the appearance of a conflict of interest. Interrupted time series design \\8\\ means a type of.... \\8\\ A single subject or single case design is an adaptation of an interrupted time series design that... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-12
... matched comparison group designs (as defined in this notice), interrupted time series designs (as defined... reading skills administered in the same way to both groups). Interrupted time series design \\3\\ means a... findings. \\3\\ A single subject or single case design is an adaptation of an interrupted time series design...
76 FR 41491 - Applications for New Awards; Arts in Education National Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-14
... the arts as a core academic subject in the school curriculum. Interrupted time series design means a... interrupted time series design that relies on the comparison of treatment effects on a single subject or group.... That is, the series should show an ``interruption'' of the prior situation at the time when the program...
Pardon Me, Can I Talk Now?: A Look at the Roles of Interruptions in Conversation.
ERIC Educational Resources Information Center
Ringer, R. Jeffrey
Several theories exist to explain the differences in the interruptive behavior of men and women. Early research suggested that men interrupt more than women, and this finding was attributed to the dominant/submissive relationship traditional in relationships among men and women. Later studies, however, found that either there were no significant…
Turner, Hugo C; Bettis, Alison A; Dunn, Julia C; Whitton, Jane M; Hollingsworth, T Déirdre; Fleming, Fiona M; Anderson, Roy M
2017-06-01
While the need for more sensitive diagnostics for intestinal helminths is well known, the cost of developing and implementing new tests is considered relatively high compared to the Kato-Katz technique. Here, we review the reported costs of performing the Kato-Katz technique. We also outline several economic arguments we believe highlight the need for further investment in alternative diagnostics, and considerations that should be made when comparing their costs. In our opinion, we highlight that, without new diagnostic methods, it will be difficult for policy makers to make the most cost-effective decisions and that the potentially higher unit costs of new methods can be outweighed by the long-term programmatic benefits they have (such as the ability to detect the interruption of transmission). Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Technical Reports Server (NTRS)
Buechler, W.; Tucker, A. G.
1981-01-01
Several methods were employed to detect both the occurrence and source of errors in the operational software of the AN/SLQ-32. A large embedded real time electronic warfare command and control system for the ROLM 1606 computer are presented. The ROLM computer provides information about invalid addressing, improper use of privileged instructions, stack overflows, and unimplemented instructions. Additionally, software techniques were developed to detect invalid jumps, indices out of range, infinte loops, stack underflows, and field size errors. Finally, data are saved to provide information about the status of the system when an error is detected. This information includes I/O buffers, interrupt counts, stack contents, and recently passed locations. The various errors detected, techniques to assist in debugging problems, and segment simulation on a nontarget computer are discussed. These error detection techniques were a major factor in the success of finding the primary cause of error in 98% of over 500 system dumps.
Wilson, Richard H; Sharrett, Kadie C
2017-01-01
Two previous experiments from our laboratory with 70 interrupted monosyllabic words demonstrated that recognition performance was influenced by the temporal location of the interruption pattern. The interruption pattern (10 interruptions/sec, 50% duty cycle) was always the same and referenced word onset; the only difference between the patterns was the temporal location of the on- and off-segments of the interruption cycle. In the first study, both young and older listeners obtained better recognition performances when the initial on-segment coincided with word onset than when the initial on-segment was delayed by 50 msec. The second experiment with 24 young listeners detailed recognition performance as the interruption pattern was incremented in 10-msec steps through the 0- to 90-msec onset range. Across the onset conditions, 95% of the functions were either flat or U-shaped. To define the effects that interruption pattern locations had on word recognition by older listeners with sensorineural hearing loss as the interruption pattern incremented, re: word onset, from 0 to 90 msec in 10-msec steps. A repeated-measures design with ten interruption patterns (onset conditions) and one uninterruption condition. Twenty-four older males (mean = 69.6 yr) with sensorineural hearing loss participated in two 1-hour sessions. The three-frequency pure-tone average was 24.0 dB HL and word recognition was ≥80% correct. Seventy consonant-vowel nucleus-consonant words formed the corpus of materials with 25 additional words used for practice. For each participant, the 700 interrupted stimuli (70 words by 10 onset conditions), the 70 words uninterrupted, and two practice lists each were randomized and recorded on compact disc in 33 tracks of 25 words each. The data were analyzed at the participant and word levels and compared to the results obtained earlier on 24 young listeners with normal hearing. The mean recognition performance on the 70 words uninterrupted was 91.0% with an overall mean performance on the ten interruption conditions of 63.2% (range: 57.9-69.3%), compared to 80.4% (range: 73.0-87.7%) obtained earlier on the young adults. The best performances were at the extremes of the onset conditions. Standard deviations ranged from 22.1% to 28.1% (24 participants) and from 9.2% to 12.8% (70 words). An arithmetic algorithm categorized the shapes of the psychometric functions across the ten onset conditions. With the older participants in the current study, 40% of the functions were flat, 41.4% were U-shaped, and 18.6% were inverted U-shaped, which compared favorably to the function shapes by the young listeners in the earlier study of 50.0%, 41.4%, and 8.6%, respectively. There were two words on which the older listeners had 40% better performances. Collectively, the data are orderly, but at the individual word or participant level, the data are somewhat volatile, which may reflect auditory processing differences between the participant groups. The diversity of recognition performances by the older listeners on the ten interruption conditions with each of the 70 words supports the notion that the term hearing loss is inclusive of processes well beyond the filtering produced by end-organ sensitivity deficits. American Academy of Audiology
Strength Training and Detraining in Different Populations: Case Studies
Marques, Mário C.; Zajac, Adam; Pereira, Ana; Costa, Aldo M.
2011-01-01
Many researchers have demonstrated that a specific strength training program can improve maximal strength and, the rate of force production, reduce the incidence of muscle-skeletal injury, and contribute to faster injury recovery times, thereby minimizing the number of missed practice sessions or competitions. Yet, to our best knowledge, there is no apparent consensus on the appropriate method of muscle strength and power training to enhance performance in distinct populations groups. Interruptions in training process because of illness, injury, holidays, post-season break or other factors are normal situations in any kind of sport. However, the detraining period and its consequences are not well reported in sports literature, and namely during puberty. Therefore, the aim of this paper was to discuss several case studies concerning different populations such us physical students, age-swimming competitors and elite power athletes. PMID:23487418
Peixoto, Luciana; Rodrigues, Alexandrina L; Martins, Gilberto; Nicolau, Ana; Brito, António G; Silva, M Manuela; Parpot, Pier; Nogueira, Regina
2013-01-01
A very compact flat microbial fuel cell (MFC), with 64 cm2 each for the anode surface and the cathode surface and 1 cm3 each for the anode and cathode chambers, was tested for wastewater treatment with simultaneous electricity production with the ultimate goal of implementing an autonomous service in decentralized wastewater treatment systems. The MFC was operated with municipal wastewater in sequencing batch reactor mode with re-circulation. Current densities up to 407 W/m3 and a carbon removal of 83% were obtained. Interruption in the operation slightly decreased power density, while the re-circulation ratio did not influence power generation. The anode biofilm presented high conductivity, activity and diversity. The denaturing gradient gel electrophoresis band-pattern of the DNA showed the presence of several ribotypes with different species of Shewanellaceae and Geobacteraceae families.
NASA Astrophysics Data System (ADS)
Junaidi, Agus; Hamid, K. Abdul
2018-03-01
This paper will discuss the use of optimal control and Power System Stabilizer (PSS) in improving the oscillation of electric power system. Oscillations in the electric power system can occur due to the sudden release of the load (Switcing-Off). The oscillation of an unstable system for a long time causes the equipment to work in an interruption. To overcome this problem, a control device is required that can work effectively in repairing the oscillation. The power system is modeled from the Single Machine Infinite Bus Model (SMIB). The state space equation is used to mathematically model SMIB. SMIB system which is a plant will be formed togetherness state variables (State-Space), using riccati equation then determined the optimal gain as controller plant. Plant is also controlled by Power Stabilizer System using phase compensation method. Using Matlab Software based simulation will be observed response of rotor speed change and rotor angle change for each of the two controlling methods. Simulation results using the Simulink-MATLAB 6.1 software will compare the analysis of the plant state in Open loop state and use the controller. The simulation response shows that the optimal control and PSS can improve the stability of the power system in terms of acceleration to achieve settling-time and Over Shoot improvement. From the results of both methods are able to improve system performance.
Power law versus exponential state transition dynamics: application to sleep-wake architecture.
Chu-Shore, Jesse; Westover, M Brandon; Bianchi, Matt T
2010-12-02
Despite the common experience that interrupted sleep has a negative impact on waking function, the features of human sleep-wake architecture that best distinguish sleep continuity versus fragmentation remain elusive. In this regard, there is growing interest in characterizing sleep architecture using models of the temporal dynamics of sleep-wake stage transitions. In humans and other mammals, the state transitions defining sleep and wake bout durations have been described with exponential and power law models, respectively. However, sleep-wake stage distributions are often complex, and distinguishing between exponential and power law processes is not always straightforward. Although mono-exponential distributions are distinct from power law distributions, multi-exponential distributions may in fact resemble power laws by appearing linear on a log-log plot. To characterize the parameters that may allow these distributions to mimic one another, we systematically fitted multi-exponential-generated distributions with a power law model, and power law-generated distributions with multi-exponential models. We used the Kolmogorov-Smirnov method to investigate goodness of fit for the "incorrect" model over a range of parameters. The "zone of mimicry" of parameters that increased the risk of mistakenly accepting power law fitting resembled empiric time constants obtained in human sleep and wake bout distributions. Recognizing this uncertainty in model distinction impacts interpretation of transition dynamics (self-organizing versus probabilistic), and the generation of predictive models for clinical classification of normal and pathological sleep architecture.
Turner, Chris; Turner, Jake
2017-12-01
: Emergency medicine is widely recognised as an intense specialty. Interruptions are known to derail thoughts, increasing cognitive load and result in longer periods before deep thought is re-established. Although approachability and warmth are regarded as important factors in clinicians we wondered what impact these characteristics had on the number of interruptions. A team of 6 medical students were trained in the use of abespoke tool to record shop floor activities. Over 4 months we conducted 100 hours of minute by minute time and motion study of emergency medicine consultants during their clinical shifts, and noted how often they were interrupted. At the end of shifts the assessors were asked a set of qualitative questions on the behaviour and attitudes of the consultants. These questions were completed in seclusion and in an anonymous format, to minimise the chance of bias/influence. QUESTIONS INCLUDED: 'How friendly was the consultant with other staff?' 'How friendly was this consultant with patients?' And, 'How would you rate this consultant's 'general positivity'?'We then assessed whether consultants that scored 'higher' inthese areas were more likely to be interrupted. Our hypothesis was that consultants who were more friendly were less intimidating for juniors and nurses to approach with questions, and so may suffer from an increase in cognitive load due to being interrupted and questioned more frequently than consultants who were felt to be less approachable.We found that consultants who scored 1(highest) in friendliness had an average of 7.38 interruptions per hour, compared to consultants who scored 3 or greater, who had an average of 3.59. Our average interruptions were close to those found in previous publications (between 6 and 9 interruptions per hour), however there was a large amount of inter-consultant variability, with one consultant during one shift being interrupted over 12 times per hour on average. If the results of this study are replicable, then it may raise questions about how best to manage this extra cognitive load. Although some may argue that being seen as slightly less friendly has an advantage in the reduction of interruptions, this may come at a cost to patient safety. There is clearly a fine balance to be made.emermed;34/12/A879-c/F1F1F1Figure 1Average interruptions per hour by friendliness score. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Viani, Marco P; Viani, Giacomo M; Sergenti, Jessica
2014-12-01
The aim of this article is to present a new technique for minimally invasive treatment of varicose veins disease of lower extremities. One-shot scleroembolization is a new technique designed for the treatment of varicose veins of the lower extremities, which associates a mechanical interruption of the sapheno-femoral junction to classic sclerotherapy with no need for surgery or anesthesia. This is achieved with the combined use of a coil positioned in the terminal portion of the great saphenous vein and a foamed sclerosant drug. At three months' follow-up no complications have been observed. The great saphenous vein was still occluded in all patients (nine out of nine). One-shot scleroembolization seems to be an effective technique for the treatment of varicose veins disease in outpatients, with the advantage of causing little distress to the patient. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation.
Pedullà, E; Lizio, A; Scibilia, M; Grande, N M; Plotino, G; Boninelli, S; Rapisarda, E; Lo Giudice, G
2017-02-01
To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Papasavvas, Emmanouil; Azzoni, Livio; Pistilli, Maxwell; Hancock, Aidan; Reynolds, Griffin; Gallo, Cecile; Ondercin, Joe; Kostman, Jay R; Mounzer, Karam; Shull, Jane; Montaner, Luis J
2008-06-19
We investigated the effect of short viremic episodes on soluble markers associated with endothelial stress and cardiovascular disease risk in chronically HIV-1-infected patients followed during continuous antiretroviral therapy, antiretroviral therapy interruption and antiretroviral therapy resumption. We assessed changes in plasma levels of von Willebrand factor, soluble vascular cell adhesion molecule-1 and intercellular adhesion molecule-1 by enzyme-linked immunosorbent assay, as well as T-cell activation (CD8+/CD38+, CD8+/HLA-DR+ and CD3+/CD95+) by flow cytometry, in 36 chronically HIV-1-infected patients participating in a randomized study. Patients were divided into the following three groups: a, on continuous antiretroviral therapy; b, on a 6-week antiretroviral therapy interruption; or c, on antiretroviral therapy interruption extended to the achievement of viral set point. Although all measurements remained stable over a 40-week follow-up on antiretroviral therapy, plasma levels of soluble vascular cell adhesion molecule-1 (P < 0.0001) and soluble intercellular adhesion molecule-1 (P = 0.003) increased during treatment interruption in correlation with viral rebound and T-cell activation. No significant changes in von Willebrand factor were observed in any of the groups. After resuming antiretroviral therapy, soluble vascular cell adhesion molecule-1 levels remained elevated even after achievement of viral suppression to less than 50 copies/ml. The prompt rise in plasma soluble vascular cell adhesion molecule-1 and soluble intercellular adhesion molecule-1 upon viral rebound suggests an acute increase in endothelial stress upon treatment interruption, which may persists after viral resuppression of virus. Thus, viral replication during short-term treatment interruption may increase the overall cardiovascular risk during and beyond treatment interruption.
Müller, Andre Matthias; Blandford, Ann; Yardley, Lucy
2017-01-01
Low physical activity and high sedentary behavior in older adults can be addressed with interventions that are delivered through modern technology. Just-In-Time Adaptive Interventions (JITAIs) are an emerging technology-driven behavior-change intervention type and capitalize on data that is collected via mobile sensing technology (e.g., smartphones) to trigger appropriate support in real-life. In this paper we integrated behavior change and aging theory and research as well as knowledge around older adult's technology use to conceptualize a JITAI targeting the reduction of sedentary behavior in older adults. The JITAIs ultimate goal is to encourage older adults to take regular activity breaks from prolonged sitting. As a proximal outcome, we suggest the number of daily activity breaks from sitting. Support provided to interrupt sitting time can be based on tailoring variables: (I) the current accumulated sitting time; (II) the location of the individual; (III) the time of the day; (IV) the frequency of daily support prompts; and (V) the response to previous support prompts. Data on these variables can be collected using sensors that are commonly inbuilt into smartphones (e.g., accelerometer, GPS). Support prompts might be best delivered via traditional text messages as older adults are usually familiar and comfortable with this function. The content of the prompts should encourage breaks from prolonged sitting by highlighting immediate benefits of sitting time interruptions. Additionally, light physical activities that could be done during the breaks should also be presented (e.g., walking into the kitchen to prepare a cup of tea). Although the conceptualized JITAI can be developed and implemented to test its efficacy, more work is required to identify ways to collect, aggregate, organize and immediately use dense data on the proposed and other potentially important tailoring variables. Machine learning and other computational modelling techniques commonly used by computer scientists and engineers appear promising. With this, to develop powerful JITAIs and to actualize the full potential of modern sensing technologies transdisciplinary approaches are required.
Blandford, Ann; Yardley, Lucy
2017-01-01
Low physical activity and high sedentary behavior in older adults can be addressed with interventions that are delivered through modern technology. Just-In-Time Adaptive Interventions (JITAIs) are an emerging technology-driven behavior-change intervention type and capitalize on data that is collected via mobile sensing technology (e.g., smartphones) to trigger appropriate support in real-life. In this paper we integrated behavior change and aging theory and research as well as knowledge around older adult's technology use to conceptualize a JITAI targeting the reduction of sedentary behavior in older adults. The JITAIs ultimate goal is to encourage older adults to take regular activity breaks from prolonged sitting. As a proximal outcome, we suggest the number of daily activity breaks from sitting. Support provided to interrupt sitting time can be based on tailoring variables: (I) the current accumulated sitting time; (II) the location of the individual; (III) the time of the day; (IV) the frequency of daily support prompts; and (V) the response to previous support prompts. Data on these variables can be collected using sensors that are commonly inbuilt into smartphones (e.g., accelerometer, GPS). Support prompts might be best delivered via traditional text messages as older adults are usually familiar and comfortable with this function. The content of the prompts should encourage breaks from prolonged sitting by highlighting immediate benefits of sitting time interruptions. Additionally, light physical activities that could be done during the breaks should also be presented (e.g., walking into the kitchen to prepare a cup of tea). Although the conceptualized JITAI can be developed and implemented to test its efficacy, more work is required to identify ways to collect, aggregate, organize and immediately use dense data on the proposed and other potentially important tailoring variables. Machine learning and other computational modelling techniques commonly used by computer scientists and engineers appear promising. With this, to develop powerful JITAIs and to actualize the full potential of modern sensing technologies transdisciplinary approaches are required PMID:29184889
Practice increases procedural errors after task interruption.
Altmann, Erik M; Hambrick, David Z
2017-05-01
Positive effects of practice are ubiquitous in human performance, but a finding from memory research suggests that negative effects are possible also. The finding is that memory for items on a list depends on the time interval between item presentations. This finding predicts a negative effect of practice on procedural performance under conditions of task interruption. As steps of a procedure are performed more quickly, memory for past performance should become less accurate, increasing the rate of skipped or repeated steps after an interruption. We found this effect, with practice generally improving speed and accuracy, but impairing accuracy after interruptions. The results show that positive effects of practice can interact with architectural constraints on episodic memory to have negative effects on performance. In practical terms, the results suggest that practice can be a risk factor for procedural errors in task environments with a high incidence of task interruption. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Increasing available FIFO space to prevent messaging queue deadlocks in a DMA environment
Blocksome, Michael A [Rochester, MN; Chen, Dong [Croton On Hudson, NY; Gooding, Thomas [Rochester, MN; Heidelberger, Philip [Cortlandt Manor, NY; Parker, Jeff [Rochester, MN
2012-02-07
Embodiments of the invention may be used to manage message queues in a parallel computing environment to prevent message queue deadlock. A direct memory access controller of a compute node may determine when a messaging queue is full. In response, the DMA may generate an interrupt. An interrupt handler may stop the DMA and swap all descriptors from the full messaging queue into a larger queue (or enlarge the original queue). The interrupt handler then restarts the DMA. Alternatively, the interrupt handler stops the DMA, allocates a memory block to hold queue data, and then moves descriptors from the full messaging queue into the allocated memory block. The interrupt handler then restarts the DMA. During a normal messaging advance cycle, a messaging manager attempts to inject the descriptors in the memory block into other messaging queues until the descriptors have all been processed.
Empowering self-defense training.
Thompson, Martha E
2014-03-01
The purpose of self-defense training is to expand people's options, yet it is often framed as a solely physical, and limiting, response to violence. I draw on my own experience as a self-defense instructor and that of others in the self-defense movement to argue that an empowerment approach to self-defense training contributes to the anti-violence movement in multiple ways: providing a pathway to increase women's and girls' safety and their potential for becoming powerful and effective social change agents right now, providing an informed and embodied understanding of violence, and offering comprehensive options to recognize, prevent, and interrupt violence.
Ultrasonic fatigue of SiC particle reinforced aluminum in the VHCF-regime
NASA Astrophysics Data System (ADS)
Wolf, M.; Wagner, G.; Eifler, D.
At the WKK ultrasonic testing facilities (UTF) are used to perform fatigue experiments in the VHCF regime with a frequency of 20 kHz. These systems allow an on-line characterization of the actual fatigue state by changes of different process parameters such as generator power, displacement, temperature or frequency-response characteristic. Moreover the experiments can be interrupted at user defined events in order to investigate variations of the surface microstructure or changes in the electrical resistance of the specimens. The fatigue tests were realized as load increase tests as well as constant amplitude tests.
Terrestrial Energy Storage SPS Systems
NASA Technical Reports Server (NTRS)
Brandhorst, Henry W., Jr.
1998-01-01
Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.
Neural and behavioral correlates of selective stopping: Evidence for a different strategy adoption.
Sánchez-Carmona, Alberto J; Albert, Jacobo; Hinojosa, José A
2016-10-01
The present study examined the neural and behavioral correlates of selective stopping, a form of inhibition that has scarcely been investigated. The selectivity of the inhibitory process is needed when individuals have to deal with an environment filled with multiple stimuli, some of which require inhibition and some of which do not. The stimulus-selective stop-signal task has been used to explore this issue assuming that all participants interrupt their ongoing responses selectively to stop but not to ignore signals. However, recent behavioral evidence suggests that some individuals do not carry out the task as experimenters expect, since they seemed to interrupt their response non-selectively to both signals. In the present study, we detected and controlled the cognitive strategy adopted by participants (n=57) when they performed a stimulus-selective stop-signal task before comparing brain activation between conditions. In order to determine both the onset and the end of the response cancellation process underlying each strategy and to fully take advantage of the precise temporal resolution of event-related potentials, we used a mass univariate approach. Source localization techniques were also employed to estimate the neural underpinnings of the effects observed at the scalp level. Our results from scalp and source level analysis support the behavioral-based strategy classification. Specific effects were observed depending on the strategy adopted by participants. Thus, when contrasting successful stop versus ignore conditions, increased activation was only evident for subjects who were classified as using a strategy whereby the response interruption process was selective to stop trials. This increased activity was observed during the P3 time window in several left-lateralized brain regions, including middle and inferior frontal gyri, as well as parietal and insular cortices. By contrast, in those participants who used a strategy characterized by stopping non-selectively, no activation differences between successful stop and ignore conditions were observed at the estimated time at which response interruption process occurs. Overall, results from the current study highlight the importance of controlling for the different strategies adopted by participants to perform selective stopping tasks before analyzing brain activation patterns. Copyright © 2016 Elsevier Inc. All rights reserved.
Using a Commercial Ethernet PHY Device in a Radiation Environment
NASA Technical Reports Server (NTRS)
Parks, Jeremy; Arani, Michael; Arroyo, Roberto
2014-01-01
This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.
Properties of Traffic Risk Coefficient
NASA Astrophysics Data System (ADS)
Tang, Tie-Qiao; Huang, Hai-Jun; Shang, Hua-Yan; Xue, Yu
2009-10-01
We use the model with the consideration of the traffic interruption probability (Physica A 387(2008)6845) to study the relationship between the traffic risk coefficient and the traffic interruption probability. The analytical and numerical results show that the traffic interruption probability will reduce the traffic risk coefficient and that the reduction is related to the density, which shows that this model can improve traffic security.
ERIC Educational Resources Information Center
Ttofi, Maria M.; Bowes, Lucy; Farrington, David P.; Lösel, Friedrich
2014-01-01
A systematic review is presented, based on prospective longitudinal studies, on protective factors that interrupt the continuity from bullying perpetration at school to externalizing problem behaviors later in life; and from bullying victimization to later internalizing problems. Some common factors were established, which seem to interrupt the…
Code of Federal Regulations, 2011 CFR
2011-07-01
... when an employee interrupts a travel assignment because of an incapacitating illness or injury? 301-70... Policies and Procedures for Emergency Travel of Employee Due to Illness or Injury § 301-70.501 Does per diem continue when an employee interrupts a travel assignment because of an incapacitating illness or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... when an employee interrupts a travel assignment because of an incapacitating illness or injury? 301-70... Policies and Procedures for Emergency Travel of Employee Due to Illness or Injury § 301-70.501 Does per diem continue when an employee interrupts a travel assignment because of an incapacitating illness or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... when an employee interrupts a travel assignment because of an incapacitating illness or injury? 301-70... Policies and Procedures for Emergency Travel of Employee Due to Illness or Injury § 301-70.501 Does per diem continue when an employee interrupts a travel assignment because of an incapacitating illness or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... when an employee interrupts a travel assignment because of an incapacitating illness or injury? 301-70... Policies and Procedures for Emergency Travel of Employee Due to Illness or Injury § 301-70.501 Does per diem continue when an employee interrupts a travel assignment because of an incapacitating illness or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... when an employee interrupts a travel assignment because of an incapacitating illness or injury? 301-70... Policies and Procedures for Emergency Travel of Employee Due to Illness or Injury § 301-70.501 Does per diem continue when an employee interrupts a travel assignment because of an incapacitating illness or...
Algorithm Design of CPCI Backboard's Interrupts Management Based on VxWorks' Multi-Tasks
NASA Astrophysics Data System (ADS)
Cheng, Jingyuan; An, Qi; Yang, Junfeng
2006-09-01
This paper begins with a brief introduction of the embedded real-time operating system VxWorks and CompactPCI standard, then gives the programming interfaces of Peripheral Controller Interface (PCI) configuring, interrupts handling and multi-tasks programming interface under VxWorks, and then emphasis is placed on the software frameworks of CPCI interrupt management based on multi-tasks. This method is sound in design and easy to adapt, ensures that all possible interrupts are handled in time, which makes it suitable for data acquisition systems with multi-channels, a high data rate, and hard real-time high energy physics.
Tajdini, Masih; Sardari, Akram; Forouzannia, Seyed Khalil; Baradaran, Abdolvahab; Hosseini, Seyed Mohammad Reza; Kassaian, Seyed Ebrahim
2016-10-01
Interrupted aortic arch is a rare congenital abnormality with a high infancy mortality rate. The principal finding is loss of luminal continuity between the ascending and descending portions of the aorta. Because of the high mortality rate in infancy, interrupted aortic arch is very rare among adults. In this report, we describe the case of a 76-year-old woman with asymptomatic interrupted aortic arch, severe tricuspid regurgitation, and bicuspid aortic valve. To our knowledge, she is the oldest patient ever reported with this possibly unique combination of pathologic conditions. In addition to reporting her case, we review the relevant medical literature.
Parke, Michael R; Weinhardt, Justin M; Brodsky, Andrew; Tangirala, Subrahmaniam; DeVoe, Sanford E
2018-03-01
Does planning for a particular workday help employees perform better than on other days they fail to plan? We investigate this question by identifying 2 distinct types of daily work planning to explain why and when planning improves employees' daily performance. The first type is time management planning (TMP)-creating task lists, prioritizing tasks, and determining how and when to perform them. We propose that TMP enhances employees' performance by increasing their work engagement, but that these positive effects are weakened when employees face many interruptions in their day. The second type is contingent planning (CP) in which employees anticipate possible interruptions in their work and plan for them. We propose that CP helps employees stay engaged and perform well despite frequent interruptions. We investigate these hypotheses using a 2-week experience-sampling study. Our findings indicate that TMP's positive effects are conditioned upon the amount of interruptions, but CP has positive effects that are not influenced by the level of interruptions. Through this study, we help inform workers of the different planning methods they can use to increase their daily motivation and performance in dynamic work environments. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Lee, Jong-Chul; Lee, Won-Ho; Kim, Woun-Jea
2015-09-01
The design and development procedures of SF6 gas circuit breakers are still largely based on trial and error through testing although the development costs go higher every year. The computation cannot cover the testing satisfactorily because all the real processes arc not taken into account. But the knowledge of the arc behavior and the prediction of the thermal-flow inside the interrupters by numerical simulations are more useful than those by experiments due to the difficulties to obtain physical quantities experimentally and the reduction of computational costs in recent years. In this paper, in order to get further information into the interruption process of a SF6 self-blast interrupter, which is based on a combination of thermal expansion and the arc rotation principle, gas flow simulations with a CFD-arc modeling are performed during the whole switching process such as high-current period, pre-current zero period, and current-zero period. Through the complete work, the pressure-rise and the ramp of the pressure inside the chamber before current zero as well as the post-arc current after current zero should be a good criterion to predict the short-line fault interruption performance of interrupters.
Carroll, Regina A; Kodak, Tiffany
2014-01-01
The type of procedure used to measure a target behavior may directly influence the perceived treatment outcomes. In the present study, we examined the influence of different data-analysis procedures on the outcomes of two commonly used treatments on the vocal stereotypy of 2 children with an autism spectrum disorder. In Study 1, we compared an interrupted and uninterrupted data-analysis procedure to measure vocal stereotypy during the implementation of response interruption and redirection (RIRD). The results showed that the interrupted data-analysis procedure overestimated the effectiveness of RIRD. In Study 2, we examined the influence of different data-analysis procedures on the interpretation of the relative effects of 2 different treatments for vocal stereotypy. Specifically, we compared interrupted and uninterrupted data-analysis procedures during the implementation of RIRD and noncontingent reinforcement (NCR) as a treatment for vocal stereotypy. The results showed that, as in Study 1, the interrupted data-analysis procedure overestimated the effectiveness of RIRD; however, this effect was not apparent with NCR. These findings suggest that different types of data analysis can influence the perceived success of a treatment. © Society for the Experimental Analysis of Behavior.
The mythology of anticoagulation therapy interruption for dental surgery.
Wahl, Michael J
2018-01-01
Continuous anticoagulation therapy is used to prevent heart attacks, strokes, and other embolic complications. When patients receiving anticoagulation therapy undergo dental surgery, a decision must be made about whether to continue anticoagulation therapy and risk bleeding complications or briefly interrupt anticoagulation therapy and increase the risk of developing embolic complications. Results from decades of studies of thousands of dental patients receiving anticoagulation therapy reveal that bleeding complications requiring more than local measures for hemostasis have been rare and never fatal. However, embolic complications (some of which were fatal and others possibly permanently debilitating) sometimes have occurred in patients whose anticoagulation therapy was interrupted for dental procedures. Although there is now virtually universal consensus among national medical and dental groups and other experts that anticoagulation therapy should not be interrupted for most dental surgery, there are still some arguments made supporting anticoagulation therapy interruption. An analysis of these arguments shows them to be based on a collection of myths and half-truths rather than on logical scientific conclusions. The time has come to stop anticoagulation therapy interruption for dental procedures. Copyright © 2018 American Dental Association. Published by Elsevier Inc. All rights reserved.
Investigating lexical competition and the cost of phonemic restoration.
Balling, Laura Winther; Morris, David Jackson; Tøndering, John
2017-12-01
Due to phonemic restoration, listeners can reliably perceive words when a phoneme is replaced with noise. The cost associated with this process was investigated along with the effect of lexical uniqueness on phonemic restoration, using data from a lexical decision experiment where noise replaced phonemes that were either uniqueness points (the phoneme at which a word deviates from all nonrelated words that share the same onset) or phonemes immediately prior to these. A baseline condition was also included with no noise-interrupted stimuli. Results showed a significant cost of phonemic restoration, with 100 ms longer word identification times and a 14% decrease in word identification accuracy for interrupted stimuli compared to the baseline. Regression analysis of response times from the interrupted conditions showed no effect of whether the interrupted phoneme was a uniqueness point, but significant effects for several temporal attributes of the stimuli, including the duration and position of the interrupted segment. These results indicate that uniqueness points are not distinct breakpoints in the cohort reduction that occurs during lexical processing, but that temporal properties of the interrupted stimuli are central to auditory word recognition. These results are interpreted in the context of models of speech perception.
Laforest, L; Van Ganse, É; Devouassoux, G; Chatté, G; Tamberou, C; Belhassen, M; Chamba, G
2015-01-01
Adherence to inhaled corticosteroids (ICS) remains a major issue for asthma management, even among patients receiving a regular prescription from their doctor. The frequency of deliberate interruption of ICS, and of spontaneous changes of dose, were studied in a population of asthma patients recruited in community pharmacies. Asthma patients (aged 18-50) recruited in community pharmacies reported in self-administered questionnaires their spontaneous interruptions and changes of doses of ICS during the past 3 months. The characteristics of patients who interrupted their therapy or who modified the dose were compared with other patients. The studied population included 252 patients (mean age 35 year-old, females: 59%), of whom 62% had inadequately controlled asthma. Among these patients, 25% had interrupted ICS therapy during the past 3 months, while 21% spontaneously changed the dose. The most reported reason for interrupting ICS was the cessation of symptoms (50%). In multivariate analysis, interrupting ICS was mainly associated with inadequate asthma control (OR=3.1, 95% CI 1.5-6.4), while the strongest association with changing ICS doses was the patients' perception of asthma as a concern in their lives (OR=3.2, 95% CI 1.2-8.4). These results underline a poor understanding of the purpose of ICS therapy by patients. They also highlight the need of therapeutic education to improve the management of the disease. Copyright © 2014 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Hayes, Carolyn; Jackson, Debra; Davidson, Patricia M; Daly, John; Power, Tamara
2017-12-01
To describe undergraduate student nurse responses to a simulated role-play experience focussing on managing interruptions during medication administration. Improving patient safety requires that we find creative and innovative methods of teaching medication administration to undergraduate nurses in real-world conditions. Nurses are responsible for the majority of medication administrations in health care. Incidents and errors associated with medications are a significant patient safety issue and often occur as a result of interruptions. Undergraduate nursing students are generally taught medication administration skills in a calm and uninterrupted simulated environment. However, in the clinical environment medication administration is challenged by multiple interruptions. A qualitative study using convenience sampling was used to examine student perceptions of a simulated role-play experience. Data were collected from 451 of a possible 528 student written reflective responses and subject to thematic analysis. Students reported an increased understanding of the impacts of interruptions while administering medications and an improved awareness of how to manage disruptions. This study reports on one of three emergent themes: "Calm to chaos: engaging with the complex nature of clinical practice." Interrupting medication administration in realistic and safe settings facilitates awareness, allows for students to begin to develop management strategies in relation to interruption and increases their confidence. Students were given the opportunity to consolidate and integrate prior and new knowledge and skills through this role-play simulation. © 2017 John Wiley & Sons Ltd.
Essays on Mathematical Optimization for Residential Demand Response in the Energy Sector
NASA Astrophysics Data System (ADS)
Palaparambil Dinesh, Lakshmi
In the electric utility industry, it could be challenging to adjust supply to match demand due to large generator ramp up times, high generation costs and insufficient in-house generation capacity. Demand response (DR) is a technique for adjusting the demand for electric power instead of the supply. Direct Load Control (DLC) is one of the ways to implement DR. DLC program participants sign up for power interruption contracts and are given financial incentives for curtailing electricity usage during peak demand time periods. This dissertation studies a DLC program for residential air conditioners using mathematical optimization models. First, we develop a model that determines what contract parameters to use in designing contracts between the provider and residential customers, when to turn which power unit on or off and how much power to cut during peak demand hours. The model uses information on customer preferences for choice of contract parameters such as DLC financial incentives and energy usage curtailment. In numerical experiments, the proposed model leads to projected cost savings of the order of 20%, compared to a current benchmark model used in practice. We also quantify the impact of factors leading to cost savings and study characteristics of customers picked by different contracts. Second, we study a DLC program in a macro economic environment using a Computable General Equilibrium (CGE) model. A CGE model is used to study the impact of external factors such as policy and technology changes on different economic sectors. Here we differentiate customers based on their preference for DLC programs by using different values for price elasticity of demand for electricity commodity. Consequently, DLC program customers could substitute demand for electricity commodity with other commodities such as transportation sector. Price elasticity of demand is calculated using a novel methodology that incorporates customer preferences for DLC contracts from the first model. The calculation of elasticity based on our methodology is useful since the prices of commodities are not only determined by aggregate demand and supply but also by customers' relative preferences for commodities. In addition to this we quantify the indirect substitution and rebound effects on sectoral activity levels, incomes and prices based on customer differences, when DLC is implemented.
NASA Technical Reports Server (NTRS)
Menkin, Evgeny; Juillerat, Robert
2015-01-01
With the International Space Station Program transition from assembly to utilization, focus has been placed on the optimization of essential resources. This includes resources both resupplied from the ground and also resources produced by the ISS. In an effort to improve the use of two of these, the ISS Engineering teams, led by the ISS Program Systems Engineering and Integration Office, undertook an effort to modify the techniques use to perform several key on-orbit events. The primary purposes of this endeavor was to make the ISS more efficient in the use of the Russian-supplied fuel for the propulsive attitude control system and also to minimize the impacts to available ISS power due to the positioning of the ISS solar arrays. Because the ISS solar arrays are sensitive to several factors that are present when propulsive attitude control is used, they must be operated in a manner to protect them from damage. This results in periods of time where the arrays must be positioned, rather than autonomously tracking the sun, resulting in negative impacts to power generated by the solar arrays and consumed by both the ISS core systems and payload customers. A reduction in the number and extent of the events each year that require the ISS to use propulsive attitude control simultaneously accomplishes both these goals. Each instance where the ISS solar arrays normal sun tracking mode must be interrupted represent a need for some level of powerdown of equipment. As the magnitude of payload power requirements increases, and the efficiency of the ISS solar arrays decreases, these powerdowns caused by array positioning, will likely become more significant and could begin to negatively impact the payload operations. Through efforts such as this, the total number of events each year that require positioning of the arrays to unfavorable positions for power generation, in order to protect them against other constraints, are reduced. Optimization of propulsive events and transitioning some of them to non-propulsive CMG control significantly reduces propellant usage on the ISS leading to the reduction of the propellant delivery requirement. This results in move available upmass that can be used for delivering critical dry cargo, additional water, air, crew supplies and science experiments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false What is my liability if, for personal convenience, I travel by an indirect route or interrupt travel by a direct route? 301-10....8 What is my liability if, for personal convenience, I travel by an indirect route or interrupt...
Interruption Practice Reduces Errors
2014-01-01
dangers of errors at the PCS. Electronic health record systems are used to reduce certain errors related to poor- handwriting and dosage...10.16, MSE =.31, p< .05, η2 = .18 A significant interaction between the number of interruptions and interrupted trials suggests that trials...the variance when calculating whether a memory has a higher signal than interference. If something in addition to activation contributes to goal
ERIC Educational Resources Information Center
Hos, Rabia
2016-01-01
The educational landscape for schools in the United States is continuing to shift with the arrival of refugee students with limited or interrupted formal education, especially at the secondary schools. As refugee students with limited or interrupted formal education (SLIFE) adjust to schools in the United States, they may experience acculturative…
GPS: Public Utility or Software Platform
2016-09-01
major occurrences that could interrupt GPS’s operation for an extended period of time . Despite these safeguards, the U.S. government has...in the event of a GPS interruption .178 2. GPS Infrastructure is designed to Prevent and Minimize Disruption Like a public utility, GPS is designed ...production and distribution while at the same time minimizing the likelihood of signal interruptions . Each of GPS’s operational satellites are
NASA Technical Reports Server (NTRS)
Wren, Paul E. (Inventor)
1983-01-01
During a distress call, a distress location transmitter 10 generates a high frequency carrier signal 40 that is modulated by a predetermined distress waveform characteristic 29. The classification of user associated with the distress call is identified by periodically interrupting modulation 42; user classification is determined by the repetition rate of the interruptions, the interruption periods, or both.
Brain dynamics during natural viewing conditions--a new guide for mapping connectivity in vivo.
Bartels, Andreas; Zeki, Semir
2005-01-15
We describe here a new way of obtaining maps of connectivity in the human brain based on interregional correlations of blood oxygen level-dependent (BOLD) signal during natural viewing conditions. We propose that anatomical connections are reflected in BOLD signal correlations during natural brain dynamics. This may provide a powerful approach to chart connectivity, more so than that based on the 'resting state' of the human brain, and it may complement diffusion tensor imaging. Our approach relies on natural brain dynamics and is therefore experimentally unbiased and independent of hypothesis-driven, specialized stimuli. It has the advantage that natural viewing leads to considerably stronger cortical activity than rest, thus facilitating detection of weaker connections. To validate our technique, we used functional magnetic resonance imaging (fMRI) to record BOLD signal while volunteers freely viewed a movie that was interrupted by resting periods. We used independent component analysis (ICA) to segregate cortical areas before characterizing the dynamics of their BOLD signal during free viewing and rest. Natural viewing and rest each revealed highly specific correlation maps, which reflected known anatomical connections. Examples are homologous regions in visual and auditory cortices in the two hemispheres and the language network consisting of Wernicke's area, Broca's area, and a premotor region. Correlations between regions known to be directly connected were always substantially higher than between nonconnected regions. Furthermore, compared to rest, natural viewing specifically increased correlations between anatomically connected regions while it decreased correlations between nonconnected regions. Our findings therefore demonstrate that natural viewing conditions lead to particularly specific interregional correlations and thus provide a powerful environment to reveal anatomical connectivity in vivo.
Maneiro Dios, Rubén; Amatria Jiménez, Mario
2018-01-01
Research in soccer has traditionally focused on very specific aspects of the game, such as technical and physiological aspects, and has largely ignored important issues such as tactical performance and the role of individual players within the team. The aim of this study was to study the different relationships that Xabi Alonso, one of the world's best midfielders, establishes with his teammates during offensive play, and to investigate his connections with the pitch in terms of where his direct interventions started and finished, his use of technical actions, his involvement in set plays and interceptions, and his relationship with shots at goal. To do this, we analyzed all the matches played by the winner of the 2012 UEFA European Championship: Spain. We employed an observational methodology design (Anguera, 1979) using a modified version of the ad hoc soccer observation instrument designed by Amatria et al. (2016). The resulting data were analyzed by polar coordinate analysis (Gorospe and Anguera, 2000), which is a powerful data reduction technique with high predictive power. The results showed significant associations (Z > 1.96; p < 0.05) between Alonso and players in different positions, a wide sphere of influence on the pitch, both for the start and end of interventions, and a strong link with game interruptions and interceptions and with the use of different technical actions. No significant associations were detected for type of shot. Studies on tactical performance that take account of the multiple factors involved in soccer will lead to better decision-making by coaches and facilitate analysis of a player's true performance. PMID:29628905
Volcanic eruption induced WWVB transmission path interruption
NASA Astrophysics Data System (ADS)
Buckmaster, H. A.; Hansen, C. H.
1985-07-01
It is reported that the 60 kHz transmission of WWVB from Fort Collins, Colorado, was not received in Calgary, Alberta, Canada, for about 11 h from 1109 UT to 2153 UT on July 23, 1980. It is suggested that this transmission path interruption is correlated with the 15 km height ash cloud due to the July 22, 1980 volcanic eruption of Mount St. Helens as it drifted eastward interrupting both the ground- and first hop sky-wave paths and that this ash cloud is the source of the conductivity and/or ionization necessary to produce this interruption. Small phase retardations are also reported which could be correlated with other Mount St. Helens volcanic events during May-July 1980.
Ishii, Kayoko; Goto, Aya; Ota, Misao; Yasumura, Seiji; Abe, Masafumi; Fujimori, Keiya
2016-08-01
Objectives The objective of this study was to assess the frequency of and factors associated with infant feeding methods after the Fukushima nuclear power plant accident using data from the Fukushima Health Management Survey. Methods We conducted an anonymous self-administered questionnaire survey of 16,001 women who gave birth around the time of the Great East Japan Earthquake and registered their pregnancies at Fukushima Prefecture municipal offices between August 1, 2010 and July 31, 2011. The responses of 8366 women were analyzed. Chi square tests and multiple logistic regression analysis were used to compare various factors between women who had formula-fed their children because of concern regarding radioactive contamination or other reasons and those who had breastfed exclusively. Results The percentage of women who had breastfed exclusively was 30.9 %. The percentage of women who had both breastfed and formula-fed or formula-fed exclusively was 69.1 %, of which 20.3 % formula-fed because of concern regarding radioactive contamination of breast milk. The use of formula feeding because of concern about radioactive contamination was significantly higher in women who had resided within the evacuation area and those whose regular antenatal care had been interrupted. The use of formula feeding for other reasons was significantly higher in women who had resided within the evacuation area and lower for those who had willingly switched to another medical institution. Conclusions for Practice Our results suggest the importance of providing breastfeeding support to women who are forced to evacuate or whose antenatal care is interrupted after a disaster.
Stent Repair for Complex Coarctation of Aorta.
Suárez de Lezo, José; Romero, Miguel; Pan, Manuel; Suárez de Lezo, Javier; Segura, José; Ojeda, Soledad; Pavlovic, Djordje; Mazuelos, Francisco; López Aguilera, José; Espejo Perez, Simona
2015-08-24
This study sought to determine whether several anatomic or evolving characteristics of the coarctation may create challenging conditions for treatment. Stent repair of coarctation of aorta is an alternative to surgical correction. We analyzed our 21-year experience in the percutaneous treatment of complex coarctation of aorta. Adverse conditions for treatment were as follow: 1) complete interruption of the aortic arch (n = 11); 2) associated aneurysm (n = 18); 3) complex stenosis (n = 30); and 4) the need for re-expansion and/or restenting (n = 21). Twenty patients (33%) belonged to more than 1 group. Ten interruptions were type A and 1 was type B. The mean length of the interrupted aorta was 9 ± 11 mm. The associated aneurysms were native in 8 patients and after previous intervention in 10 patients. Aneurysm shapes were fusiform in 8 patients and saccular in 10. The following characteristics defined complex stenosis as long diffuse stenosis, very tortuous coarctation, or stenosis involving a main branch or an unusual location. Patients previously stented at an early age, required re-expansion and/or restenting after reaching 16 ± 5 years of age. Two patients had died by 1-month follow-up. The remaining 58 patients did well and were followed-up for a mean period of 10 ± 6 years. Late adverse events occurred in 3 patients (5%). All remaining patients are symptom-free, with normal baseline blood pressure. Imaging techniques revealed good patency at follow-up without associated aneurysm or restenosis. The actuarial survival free probability of all complex patients at 15 years was 92%. Stent repair of complex coarctation of aorta is feasible and safe. Initial results are maintained at later follow-up. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Tóth, F; Nissi, M J; Wang, L; Ellermann, J M; Carlson, C S
2015-02-01
Identify and interrupt the vascular supply to portions of the distal femoral articular-epiphyseal cartilage complex (AECC) in goat kids to induce cartilage necrosis, characteristic of early lesions of osteochondrosis (OC); then utilize magnetic resonance imaging (MRI) to identify necrotic areas of cartilage. Distal femora were perfused and cleared in goat kids of various ages to visualize the vascular supply to the distal femoral AECC. Vessels located on the axial aspect of the medial femoral condyle (MFC) and on the abaxial side of the lateral trochlear ridge were transected in eight 4- to 5-day-old goats to induce cartilage necrosis. Goats were euthanized 1, 2, 3, 4, 5, 6, 9, and 10 weeks post operatively and operated stifles were harvested. Adiabatic T1ρ relaxation time maps of the harvested distal femora were generated using a 9.4 T MR scanner, after which samples were evaluated histologically. Interruption of the vascular supply to the MFC caused lesions of cartilage necrosis in 6/8 goat kids that were demonstrated histologically. Adiabatic T1ρ relaxation time mapping identified these areas of cartilage necrosis in 5/6 cases. No significant findings were detected after transection of perichondrial vessels supplying the lateral trochlear ridge. Cartilage necrosis, characteristic of early OC, can be induced by interrupting the vascular supply to the distal femoral AECC in goat kids. The ability of high field MRI to identify these areas of cartilage necrosis in the AECC using the adiabatic T1ρ sequence suggests that this technique may be useful in the future for the early diagnosis of OC. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Lindpointner, Stefan; Korsatko, Stefan; Tutkur, Dina; Bodenlenz, Manfred; Pieber, Thomas R.
2013-01-01
Abstract Background Treatment of type 1 diabetes patients could be simplified if the site of subcutaneous insulin infusion could also be used for the measurement of glucose. This study aimed to assess the agreement between blood glucose concentrations and glucose levels in the interstitial fluid (ISF) that is extracted from the insulin infusion site during periodic short-term interruptions of continuous subcutaneous insulin infusion (CSII). Subjects and Methods A perforated cannula (24 gauge) was inserted into subcutaneous adipose tissue of C-peptide-negative type 1 diabetes subjects (n=13) and used alternately to infuse rapid-acting insulin (100 U/mL) and to extract ISF glucose during a fasting period and after ingestion of a standard oral glucose load (75 g). Results Although periodically interrupted for extracting glucose (every hour for approximately 10 min), insulin infusion with the cannula was adequate to achieve euglycemia during fasting and to restore euglycemia after glucose ingestion. Furthermore, the ISF-derived estimates of plasma glucose levels agreed well with plasma glucose concentrations. Correlation coefficient and median absolute relative difference values were found to be 0.95 and 8.0%, respectively. Error grid analysis showed 99.0% of all ISF glucose values within clinically acceptable Zones A and B (83.5% Zone A, 15.5% Zone B). Conclusions Results show that ISF glucose concentrations measured at the insulin infusion site during periodic short-term interruptions of CSII closely reflect blood glucose levels, thus suggesting that glucose monitoring and insulin delivery may be performed alternately at the same tissue site. A single-port device of this type could be used to simplify and improve glucose management in diabetes. PMID:23126579
[Guidelines on medically assisted reproduction: legal issues and professional liability].
Molinelli, A; Motroni Gherardi, S M; Picchioni, D M; Ventura, F
2007-08-01
The authors analyze the legal and medico-legal issues deriving from the recent Law No. 40 of February 19, 2004 concerning the Medically Assisted Reproduction. In particular, they analyze the contrasting points between the dispositions of Law No. 40/2004 and those of Law No. 194/1978 on the voluntary interruption of pregnancy, and they analyze the guidelines about the procedures and the techniques of the Medically Assisted Reproduction, issued by the Ministry of Health with D.M. of July 21, 2004. The Guidelines, as well as some sentences of several courts, lead to some reflections also about the consent and the professional liability, in particular considering the various moments of the medical action, from the first interview to the carrying out of the assisted reproduction techniques.
Havens: Explicit Reliable Memory Regions for HPC Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hukerikar, Saurabh; Engelmann, Christian
2016-01-01
Supporting error resilience in future exascale-class supercomputing systems is a critical challenge. Due to transistor scaling trends and increasing memory density, scientific simulations are expected to experience more interruptions caused by transient errors in the system memory. Existing hardware-based detection and recovery techniques will be inadequate to manage the presence of high memory fault rates. In this paper we propose a partial memory protection scheme based on region-based memory management. We define the concept of regions called havens that provide fault protection for program objects. We provide reliability for the regions through a software-based parity protection mechanism. Our approach enablesmore » critical program objects to be placed in these havens. The fault coverage provided by our approach is application agnostic, unlike algorithm-based fault tolerance techniques.« less
Workflow interruptions, cognitive failure and near-accidents in health care.
Elfering, Achim; Grebner, Simone; Ebener, Corinne
2015-01-01
Errors are frequent in health care. A specific model was tested that affirms failure in cognitive action regulation to mediate the influence of nurses' workflow interruptions and safety conscientiousness on near-accidents in health care. One hundred and sixty-five nurses from seven Swiss hospitals participated in a questionnaire survey. Structural equation modelling confirmed the hypothesised mediation model. Cognitive failure in action regulation significantly mediated the influence of workflow interruptions on near-accidents (p < .05). An indirect path from conscientiousness to near-accidents via cognitive failure in action regulation was also significant (p < .05). Compliance with safety regulations was significantly related to cognitive failure and near-accidents; moreover, cognitive failure mediated the association between compliance and near-accidents (p < .05). Contrary to expectations, compliance with safety regulations was not related to workflow interruptions. Workflow interruptions caused by colleagues, patients and organisational constraints are likely to trigger errors in nursing. Work redesign is recommended to reduce cognitive failure and improve safety of nurses and patients.
Causal role for the subthalamic nucleus in interrupting behavior
Fife, Kathryn H; Gutierrez-Reed, Navarre A; Zell, Vivien; Bailly, Julie; Lewis, Christina M; Aron, Adam R; Hnasko, Thomas S
2017-01-01
Stopping or pausing in response to threats, conflicting information, or surprise is fundamental to behavior. Evidence across species has shown that the subthalamic nucleus (STN) is activated by scenarios involving stopping or pausing, yet evidence that the STN causally implements stops or pauses is lacking. Here we used optogenetics to activate or inhibit mouse STN to test its putative causal role. We first demonstrated that optogenetic stimulation of the STN excited its major projection targets. Next we showed that brief activation of STN projection neurons was sufficient to interrupt or pause a self-initiated bout of licking. Finally, we developed an assay in which surprise was used to interrupt licking, and showed that STN inhibition reduced the disruptive effect of surprise. Thus STN activation interrupts behavior, and blocking the STN blunts the interruptive effect of surprise. These results provide strong evidence that the STN is both necessary and sufficient for such forms of behavioral response suppression. DOI: http://dx.doi.org/10.7554/eLife.27689.001 PMID:28742497
Implementation Plan for Flexible Automation in U.S. Shipyards
1985-01-01
process steps, cramped work sites, interrupted geometries , irregular or novel shapes, and other factors that affect automatability. We also try to...held by 2 hands in awkward places. Interrupt geometry of plates and beams. Cannot predict outcome. Creates need to measure and recut. Automation, if...of standard. enough over time I every job. I Rearrange work.Redefine work units. Too many interruptions Time, space, geometry only a little work gets
Knorre, P
1976-01-01
In the third stage of labour we must expect an increase of blood lost and placental retentions after preceded interruption. An accumulation of manual detaching of placenta we ascertained for preceded abortion only. In the childbed we found an certained increase of disturbances in uterine involution. We think, that some consequences for medical care in pregnancies, following abortion and interruption, are very important.
NASA Astrophysics Data System (ADS)
Houng, Y. M.; Tan, M. R. T.; Liang, B. W.; Wang, S. Y.; Yang, L.; Mars, D. E.
1994-03-01
We report the growth of InGaAs/GaAs vertical cavity surface emitting lasers (VCSELs) with an emission wavelength at 0.98 μm by gas-source molecular beam epitaxy (GSMBE). The surface emitting laser diodes are composed of a 15-pair p + GaAs/AlAs graded mirror with a 3-quantum well In 0.2Ga 0.8As active region and a 16.5-pair n + GaAs/AlAs grade mirror on an n + GaAs substrate. We use a simple interferometric technique for in-situ monitoring and feedback control of layer thickness to obtain a highly reproducible Bragg reflector. This technique uses an optical pyrometer to measure apparent temperature oscillations of the growing epi-layer surface. These measurements can be performed with continuous substrate rotation and without any growth interruption. The growing layer thickness can then be related to the apparent temperature oscillation spectrum. When the layer reaches the desired thickness, the growth of the subsequent layer is then initiated. By making layer thickness measurements and control in real-time throughout the entire growth cycle of the structure, the center of the mirror reflectivity and the Fabry-Pérot resonance at the desired wavelength can be reproducibly obtained. The reproducibility of the center wavelength and FWHM of the reflectivity stop-band with a variation of ≤ 0.2% was achieved in the AlAs/GaAs mirror stacks grown using this technique. The VCSEL structures with a variation of the Fabry-Pérot wavelength of ≤ 0.4% have been grown. Bottom-emitting laser diodes were fabricated and operated CW at room temperature. CW threshold currents of 3 and 6 mA are measured at room temperature for 10 and 25 μm diameter lasers, respectively. Output powers higher than 15 mW are obtained from these devices. These devices have an external quantum efficiency higher than 40%.
Kieran, Maríosa; Cleary, Mary; De Brún, Aoife; Igoe, Aileen
2017-10-01
To improve efficiency, reduce interruptions and reduce the time taken to complete oral drug rounds. Lean Six Sigma methods were applied to improve drug round efficiency using a pre- and post-intervention design. A 20-bed orthopaedic ward in a large teaching hospital in Ireland. Pharmacy, nursing and quality improvement staff. A multifaceted intervention was designed which included changes in processes related to drug trolley organization and drug supply planning. A communications campaign aimed at reducing interruptions during nurse-led during rounds was also developed and implemented. Average number of interruptions, average drug round time and variation in time taken to complete drug round. At baseline, the oral drug round took an average of 125 min. Following application of Lean Six Sigma methods, the average drug round time decreased by 51 min. The average number of interruptions per drug round reduced from an average of 12 at baseline to 11 following intervention, with a 75% reduction in drug supply interruptions. Lean Six Sigma methodology was successfully employed to reduce interruptions and to reduce time taken to complete the oral drug round. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Jandoc, Racquel; Burden, Andrea M; Mamdani, Muhammad; Lévesque, Linda E; Cadarette, Suzanne M
2015-08-01
To describe the use and reporting of interrupted time series methods in drug utilization research. We completed a systematic search of MEDLINE, Web of Science, and reference lists to identify English language articles through to December 2013 that used interrupted time series methods in drug utilization research. We tabulated the number of studies by publication year and summarized methodological detail. We identified 220 eligible empirical applications since 1984. Only 17 (8%) were published before 2000, and 90 (41%) were published since 2010. Segmented regression was the most commonly applied interrupted time series method (67%). Most studies assessed drug policy changes (51%, n = 112); 22% (n = 48) examined the impact of new evidence, 18% (n = 39) examined safety advisories, and 16% (n = 35) examined quality improvement interventions. Autocorrelation was considered in 66% of studies, 31% reported adjusting for seasonality, and 15% accounted for nonstationarity. Use of interrupted time series methods in drug utilization research has increased, particularly in recent years. Despite methodological recommendations, there is large variation in reporting of analytic methods. Developing methodological and reporting standards for interrupted time series analysis is important to improve its application in drug utilization research, and we provide recommendations for consideration. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Photodiode-based cutting interruption sensor for near-infrared lasers.
Adelmann, B; Schleier, M; Neumeier, B; Hellmann, R
2016-03-01
We report on a photodiode-based sensor system to detect cutting interruptions during laser cutting with a fiber laser. An InGaAs diode records the thermal radiation from the process zone with a ring mirror and optical filter arrangement mounted between a collimation unit and a cutting head. The photodiode current is digitalized with a sample rate of 20 kHz and filtered with a Chebyshev Type I filter. From the measured signal during the piercing, a threshold value is calculated. When the diode signal exceeds this threshold during cutting, a cutting interruption is indicated. This method is applied to sensor signals from cutting mild steel, stainless steel, and aluminum, as well as different material thicknesses and also laser flame cutting, showing the possibility to detect cutting interruptions in a broad variety of applications. In a series of 83 incomplete cuts, every cutting interruption is successfully detected (alpha error of 0%), while no cutting interruption is reported in 266 complete cuts (beta error of 0%). With this remarkable high detection rate and low error rate, the possibility to work with different materials and thicknesses in combination with the easy mounting of the sensor unit also to existing cutting machines highlight the enormous potential for this sensor system in industrial applications.
Simulation-Based Testing of Pager Interruptions During Laparoscopic Cholecystectomy.
Sujka, Joseph A; Safcsak, Karen; Bhullar, Indermeet S; Havron, William S
2018-01-30
To determine if pager interruptions affect operative time, safety, or complications and management of pager issues during a simulated laparoscopic cholecystectomy. Twelve surgery resident volunteers were tested on a Simbionix Lap Mentor II simulator. Each resident performed 6 randomized simulated laparoscopic cholecystectomies; 3 with pager interruptions (INT) and 3 without pager interruptions (NO-INT). The pager interruptions were sent in the form of standardized patient vignettes and timed to distract the resident during dissection of the critical view of safety and clipping of the cystic duct. The residents were graded on a pass/fail scale for eliciting appropriate patient history and management of the pager issue. Data was extracted from the simulator for the following endpoints: operative time, safety metrics, and incidence of operative complications. The Mann-Whitney U test and contingency table analysis were used to compare the 2 groups (INT vs. NO-INT). Level I trauma center; Simulation laboratory. Twelve general surgery residents. There was no significant difference between the 2 groups in any of the operative endpoints as measured by the simulator. However, in the INT group, only 25% of the time did the surgery residents both adequately address the issue and provide effective patient management in response to the pager interruption. Pager interruptions did not affect operative time, safety, or complications during the simulated procedure. However, there were significant failures in the appropriate evaluations and management of pager issues. Consideration for diversion of patient care issues to fellow residents not operating to improve quality and safety of patient care outside the operating room requires further study. Copyright © 2018. Published by Elsevier Inc.
Arjona, M Montes de Oca; Pérez-Cano, R; Garcia-Juárez, R; Martín-Aspas, A; del Alamo, C Fernández Gutiérrez; Girón-González, J A
2006-04-01
The changes in nutritional parameters and adipocytokines after structured intermittent interruption of highly active antiretroviral treatment of patients with chronic HIV infection are analyzed. Twenty-seven patients with chronic HIV infection (median CD4+ T cell count/microl: nadir, 394; at the beginning of structured interruptions, 1041; HIV viral load: nadir, 41,521 copies/ml; at the beginning of structured interruptions <50 copies/ml; median time of previous treatment: 60 months) were evaluated during three cycles of intermittent interruptions of therapy (8 weeks on/4 weeks off). CD4+ T cell count, HIV viral load, anthropometric measures, and serum concentrations of triglycerides, cholesterol, leptin, and tumor necrosis factor and its soluble receptors I and II were determined. After the three cycles of intermittent interruptions of therapy, no significant differences in CD4+ T cell count/microl, viral load, or serum concentrations of cholesterol or triglycerides with reference to baseline values were found. A near-significant higher fatty mass (skinfold thicknesses, at the end, 121 mm, at the beginning, 100 mm, p = 0.100), combined with a significant increase of concentration of leptin (1.5 vs. 4.7 ng/ml, p = 0,044), as well as a decrease in serum concentrations of soluble receptors of tumor necrosis factor (TNFRI, 104 vs. 73 pg/ml, p = 0.022; TNFRII 253 vs. 195 pg/ml, p = 0.098) were detected. Structured intermittent interruption of highly active antiretroviral treatment of patients with chronic HIV infection induces a valuable positive modification in markers of lipid turnover and adipose tissue mass.
Epstein, R H; Dexter, F
2012-09-01
Perioperative interruptions generated electronically from anaesthesia information management systems (AIMS) can provide useful feedback, but may adversely affect task performance if distractions occur at inopportune moments. Ideally such interruptions would occur only at times when their impact would be minimal. In this study of AIMS data, we evaluated the times of comments, drugs, fluids and periodic assessments (e.g. electrocardiogram diagnosis and train-of-four) to develop recommendations for the timing of interruptions during the intraoperative period. The 39,707 cases studied were divided into intervals between: 1) enter operating room; 2) induction; 3) intubation; 4) surgical incision; and 5) end surgery. Five-minute intervals of no documentation were determined for each case. The offsets from the start of each interval when >50% of ongoing cases had completed initial documentation were calculated (MIN50). The primary endpoint for each interval was the percentage of all cases still ongoing at MIN50. Results were that the intervals from entering the operating room to induction and from induction to intubation were unsuitable for interruptions confirming prior observational studies of anaesthesia workload. At least 13 minutes after surgical incision was the most suitable time for interruptions with 92% of cases still ongoing. Timing was minimally affected by the type of anaesthesia, surgical facility, surgical service, prone positioning or scheduled case duration. The implication of our results is that for mediated interruptions, waiting at least 13 minutes after the start of surgery is appropriate. Although we used AIMS data, operating room information system data is also suitable.
Power supply sharing in the Apollo telescope mount electrical power system
NASA Technical Reports Server (NTRS)
Lanier, R., Jr.; Kapustka, R.
1977-01-01
A modular dc power supply power sharing technique was developed for the Apollo telescope mount electrical power sytem on Skylab. The advantages and disadvantages of various techniques used are reviewed and compared. The new technique design is discussed, and results of its implementation in the power system are reviewed.