Science.gov

Sample records for power line corridor

  1. Remote sensing methods for power line corridor surveys

    NASA Astrophysics Data System (ADS)

    Matikainen, Leena; Lehtomäki, Matti; Ahokas, Eero; Hyyppä, Juha; Karjalainen, Mika; Jaakkola, Anttoni; Kukko, Antero; Heinonen, Tero

    2016-09-01

    To secure uninterrupted distribution of electricity, effective monitoring and maintenance of power lines are needed. This literature review article aims to give a wide overview of the possibilities provided by modern remote sensing sensors in power line corridor surveys and to discuss the potential and limitations of different approaches. Monitoring of both power line components and vegetation around them is included. Remotely sensed data sources discussed in the review include synthetic aperture radar (SAR) images, optical satellite and aerial images, thermal images, airborne laser scanner (ALS) data, land-based mobile mapping data, and unmanned aerial vehicle (UAV) data. The review shows that most previous studies have concentrated on the mapping and analysis of network components. In particular, automated extraction of power line conductors has achieved much attention, and promising results have been reported. For example, accuracy levels above 90% have been presented for the extraction of conductors from ALS data or aerial images. However, in many studies datasets have been small and numerical quality analyses have been omitted. Mapping of vegetation near power lines has been a less common research topic than mapping of the components, but several studies have also been carried out in this field, especially using optical aerial and satellite images. Based on the review we conclude that in future research more attention should be given to an integrated use of various data sources to benefit from the various techniques in an optimal way. Knowledge in related fields, such as vegetation monitoring from ALS, SAR and optical image data should be better exploited to develop useful monitoring approaches. Special attention should be given to rapidly developing remote sensing techniques such as UAVs and laser scanning from airborne and land-based platforms. To demonstrate and verify the capabilities of automated monitoring approaches, large tests in various environments

  2. Assessment of frequent cutting as a plant-community management technique in power-line corridors

    NASA Astrophysics Data System (ADS)

    Luken, James O.; Hinton, Andrew C.; Baker, Douglas G.

    1991-05-01

    Repeated cutting of vegetation at or near ground level in power-line corridors is a common practice for inhibiting tree growth and regeneration. However, few data exist on long-term community responses. In this study, we sampled 20 northern Kentucky power-line corridors and compared their seedling and sapling communities to the edges and interiors of adjacent undisturbed forests. Mean seedling and sapling density in corridors was roughly twice that of adjacent undisturbed forest interiors, suggesting that repeated cutting is not a viable method of inhibiting tree regeneration. Corridor communities were dominated by Robinia pseudoacacia (black locust) and Fraxinus americana (white ash), but ordinations indicated strong similaritties among communities in corridors and adjacent forests. Many of the tree species found in adjacent forests, with the exception of a few shade-tolerant species, had highest seedling and sapling densities in corridors. Stump or root sprouting by many species appears to regenerate forests quickly after cutting. However, disturbed soil and detritus accumulations caused by management crews and their equipment may also create a large variety of microsites for seedling establishment. Because repeated cutting selects for dominance by species with highest sprout growth rates, it should not be used as the sole management technique. It may instead be used to alter the vigor, stature, and stored reserves of trees so that herbicides or other methods of tree control can be used more efficiently.

  3. Urban Power Line Corridors as Novel Habitats for Grassland and Alien Plant Species in South-Western Finland

    PubMed Central

    Lampinen, Jussi; Ruokolainen, Kalle; Huhta, Ari-Pekka

    2015-01-01

    Regularly managed electric power line corridors may provide habitats for both early-successional grassland plant species and disturbance-dependent alien plant species. These habitats are especially important in urban areas, where they can help conserve native grassland species and communities in urban greenspace. However, they can also provide further footholds for potentially invasive alien species that already characterize urban areas. In order to implement power line corridors into urban conservation, it is important to understand which environmental conditions in the corridors favor grassland species and which alien species. Likewise it is important to know whether similar environmental factors in the corridors control the species composition of the two groups. We conducted a vegetation study in a 43 kilometer long urban power line corridor network in south-western Finland, and used generalized linear models and distance-based redundancy analysis to determine which environmental factors best predict the occurrence and composition of grassland and alien plant species in the corridors. The results imply that old corridors on dry soils and steep slopes characterized by a history as open areas and pastures are especially suitable for grassland species. Corridors suitable for alien species, in turn, are characterized by productive soils and abundant light and are surrounded by a dense urban fabric. Factors controlling species composition in the two groups are somewhat correlated, with the most important factors including light abundance, soil moisture, soil calcium concentration and soil productivity. The results have implications for grassland conservation and invasive alien species control in urban areas. PMID:26565700

  4. Urban Power Line Corridors as Novel Habitats for Grassland and Alien Plant Species in South-Western Finland.

    PubMed

    Lampinen, Jussi; Ruokolainen, Kalle; Huhta, Ari-Pekka

    2015-01-01

    Regularly managed electric power line corridors may provide habitats for both early-successional grassland plant species and disturbance-dependent alien plant species. These habitats are especially important in urban areas, where they can help conserve native grassland species and communities in urban greenspace. However, they can also provide further footholds for potentially invasive alien species that already characterize urban areas. In order to implement power line corridors into urban conservation, it is important to understand which environmental conditions in the corridors favor grassland species and which alien species. Likewise it is important to know whether similar environmental factors in the corridors control the species composition of the two groups. We conducted a vegetation study in a 43 kilometer long urban power line corridor network in south-western Finland, and used generalized linear models and distance-based redundancy analysis to determine which environmental factors best predict the occurrence and composition of grassland and alien plant species in the corridors. The results imply that old corridors on dry soils and steep slopes characterized by a history as open areas and pastures are especially suitable for grassland species. Corridors suitable for alien species, in turn, are characterized by productive soils and abundant light and are surrounded by a dense urban fabric. Factors controlling species composition in the two groups are somewhat correlated, with the most important factors including light abundance, soil moisture, soil calcium concentration and soil productivity. The results have implications for grassland conservation and invasive alien species control in urban areas.

  5. Mapping threats to power line corridors for Connecticut rights-of-way management.

    PubMed

    Poulos, H M; Camp, A E

    2011-02-01

    Trees are a major threat to power line security across forested regions of the world. We developed a decision support system for identifying locations in Connecticut, USA where trees have grown tall enough to make contact with transmission lines during storms. We used the Random Forest algorithm, danger tree presence/absence data, and 25 raster environmental datasets to develop (1) an understanding of the abiotic environmental settings that host danger trees and (2) a spatially explicit map of danger tree distributions across Connecticut power line corridors. Danger trees were prevalent in locations (1) with an infrequent history of storms; (2) forested and residential land uses; and (3) low to middle elevations. Products from this research can be transferred to adaptive right-of-way management because they present managers with key information on where danger trees are likely to occur, and the methods presented herein have great potential for future application to other regions managers seek to identify high priority areas for danger tree removal.

  6. Target and nontarget discrimination of herbicides applied to vegetation in a power-line corridor

    NASA Astrophysics Data System (ADS)

    Luken, James O.; Beiting, Steven W.; Kareth, Scott K.; Kumler, Robyn L.; Liu, Jun H.; Seither, Craig A.

    1994-03-01

    We tested two cutting regimens (cut/spray and cut/delay spray) and four radiarc-applied herbicides (Garlon + Tordon, Accord, Accord + Escort, and Krenite) in an Ohio power-line corridor to determine which management combination best eliminated target species (i.e., trees) and preserved nontarget species (i.e., low shrubs, vines, perennial herbs, and grasses). When spraying was delayed after cutting, the herbicide with the least impact on nontarget species (Krenite) also was least efficient at killing target trees. Spraying soon after cutting improved tree-killing efficiency of several herbicides, but it also increased the negative impact on nontarget species. The herbicide with the most consistent tree-killing ability (Accord + Escort) had the most impact on nontarget species. Because none of the herbicide/cutting treatments performed ideally, resource managers must decide the acceptable impact on nontarget species when considering herbicide use. Future success of herbicides as part of an integrated succession management approach requires more selective application methods and formulations so that target effects can be maximized and nontarget effects can be minimized.

  7. Reclamation and revegetation along a 250-mile 500 kV power line corridor

    SciTech Connect

    Griffith, E.F.

    1990-12-31

    Reclamation and revegetation success along the Montana Power Company Colstrip to Deepdale 500 kV powerline was monitored from 1985 through 1989. Followup revegetation was hampered by inadequate road and tower site earth work as a result of premature release of the reclamation bond. Drought conditions in 1985 and 1988 seriously affected revegetation efforts, especially on difficult sites. Weed control improved markedly, and all ROW areas are weed free except those next to infested range and cropland where a major cooperative effort is needed to control weeds. Access roads in previously unroaded areas resulted in changes of access, management practices, and cattle grazing behavior, all of which adversely affected revegetation success. Erosion, exacerbated by undersized culverts, the presence of very erodible soils, the occasional untrained contractor, is now the major ROW maintenance concern. Observation of the revegetation efforts clearly shows the need for adequate and appropriate reclamation by qualified equipment operators up front, and a patient, measured effort of continued revegetation, weed control and erosion control over the long term. The bond period of 5 years may not be long enough to achieve the 90 percent revegetation success required by the permit. Future projects guidelines should consider look to a flexible timeframe and more realistic vegetation requirements to account for the effects of non-construction related impacts.

  8. Concurrent Wind Cooling in Power Transmission Lines

    SciTech Connect

    Jake P Gentle

    2012-08-01

    Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

  9. Freight train scheduling on a single line corridor

    NASA Astrophysics Data System (ADS)

    Rahman, Amirah; Froyland, Gary

    2014-09-01

    Most of the world's freight rail network consists of single track lines with sidings where interactions between trains occur (meet, pass). The goal is to generate a schedule where the trains spend as little time as possible traversing between loading and unloading stations while ensuring that the interactions happen safely. Currently, scheduling is a manual operation performed by train controllers or dispatchers. The complexity of the problem makes it a demanding and highly time consuming task. We present an integer program formulation and results obtained from numerical experiments.

  10. Placing power linres : GIS helps site energy corridors.

    SciTech Connect

    Kuiper, J. A.; Cantwell, B.; Hlohowskyj, I.; Moore, H. R.

    2011-08-01

    Turn the lights on when you enter a room, then turn the lights off when you leave. Most of us repeat this sequence many times each day, and never give it another thought. But that seemingly simple light switch on the wall connects us to one of the most complex systems in the world: the electrical grid. Most of the United States is served by a highly reliable and adequate supply of electrical power, which is distributed through a grid of thousands of miles of electricity-transmission lines. However, as the electricity-supply infrastructure ages and consumer demand for electricity grows, the capacity to deliver electrical power hasn't kept pace with demand, and upgrading the electrical-transmission grid has become a more pressing need. From 1988-1998, demand for transmission grew by 30 percent while transmission grew by only 15 percent. From 1999-2009, demand grew by 20 percent and transmission by only 3 percent Despite a short-term decline related to the economic downturn and improved efficiency, U.S. energy consumption is expected to increase by 14 percent between 2008 and 2035. This growth will drive the need to develop viable routes for new transmission lines. Because transmission lines extend over large distances, they typically cross many federal, tribal, state, local and private land jurisdictions, each with a complex and varying set of siting issues and land-management practices. And as the existing grid needs improvement to meet growing demand, the U.S. is rapidly developing renewable energy sources, particularly solar and wind energy, often in areas far removed from existing electricity-transmission infrastructure and energy-consumption areas.

  11. Power line detection system

    DOEpatents

    Latorre, Victor R.; Watwood, Donald B.

    1994-01-01

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

  12. Power line detection system

    DOEpatents

    Latorre, V.R.; Watwood, D.B.

    1994-09-27

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

  13. Common raven occurrence in relation to energy transmission line corridors transiting human-altered sagebrush steppe

    USGS Publications Warehouse

    Coates, Peter S.; Howe, Kristy B.; Casazza, Michael L.; Delehanty, David J.

    2014-01-01

    Energy-related infrastructure and other human enterprises within sagebrush steppe of the American West often results in changes that promote common raven (Corvus corax; hereafter, raven) populations. Ravens, a generalist predator capable of behavioral innovation, present a threat to many species of conservation concern. We evaluate the effects of detailed features of an altered landscape on the probability of raven occurrence using extensive raven survey (n= 1045) and mapping data from southern Idaho, USA. We found nonlinear relationships between raven occurrence and distances to transmission lines, roads, and facilities. Most importantly, raven occurrence was greater with presence of transmission lines up to 2.2 km from the corridor.We further explain variation in raven occurrence along anthropogenic features based on the amount of non-native vegetation and cover type edge, such that ravens select fragmented sagebrush stands with patchy, exotic vegetative introgression. Raven occurrence also increased with greater length of edge formed by the contact of big sagebrush (Artemisia tridentate spp.) with non-native vegetation cover types. In consideration of increasing alteration of sagebrush steppe, these findings will be useful for planning energy transmission corridor placement and other management activities where conservation of sagebrush obligate species is a priority.

  14. Power transmission line monitoring system

    SciTech Connect

    Seppa, T.O.

    1993-08-17

    A method for monitoring the sag of an overhead power transmission line comprising the steps of: measuring the tension of the power line; producing an electrical signal representative of the tension measurement; processing said electrical signal in accordance with a predetermined tension-sag relationship to produce a second signal which is a function of sag of the power line; transmitting said second electrical signal to a distant location in a predetermined transmission mode; receiving the second signal at the distant location whereby current in the power line is adjusted in accordance with the received second signal.

  15. Engineering analysis of electrical effects for the COTP 500KV transmission line and EBMUD aqueduct corridor

    SciTech Connect

    Lewis, O.C.; Bell, G.K.; Ma, J.

    1995-12-31

    A study was conducted to determine AC electrical interference effects arising in the East Bay Municipal Utility District`s (EBMUD) Mokelumne Aqueducts due to their proximity to the Olinda-Tracy 500 kilovolt (kV) transmission line operated by the Western Area Power Administration (WESTERN). A six-wire gradient control wire mitigation system selected by EBMUD was modeled and evaluated. The study shows that the mitigation system performs satisfactorily under all conditions examined. During steady state conditions, touch voltages are maintained below 15 volts throughout the entire length of the three aqueducts. During fault conditions, touch voltages are maintained below 263 volts, the design limit calculated according to ANSI/IEEE Standard 80. The currents flowing through the isolator/surge protectors do not exceed the ratings of these devices, during steady state and fault conditions.

  16. Ames Lab 101: Next Generation Power Lines

    SciTech Connect

    Russell, Alan

    2010-01-01

    Ames Laboratory scientist Alan Russell discusses the need to develop new power lines that are stronger and more conductive as a way to address the problem of the nation's aging and inadequate power grid.

  17. Ames Lab 101: Next Generation Power Lines

    ScienceCinema

    Russell, Alan

    2016-07-12

    Ames Laboratory scientist Alan Russell discusses the need to develop new power lines that are stronger and more conductive as a way to address the problem of the nation's aging and inadequate power grid.

  18. ULTRA HIGH POWER TRANSMISSION LINE TECHNIQUES

    DTIC Science & Technology

    The ultra-high power transmission line techniques including both failure mechanisms and component design are discussed. Failures resulting from...a waveguide. In view of the many advantages of the low loss mode in circular waveguide for ultra-high power levels, a mode transducer and a two...percent of the peak power of a standard rectangular wave guide. Water cooling is provided for high average power operation. Analysis of mode sup pression

  19. 3. GENERAL VIEW OF CORRIDOR AROUND TRENTON STATION. TRENTON, MERCER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. GENERAL VIEW OF CORRIDOR AROUND TRENTON STATION. TRENTON, MERCER CO., NJ. Sec. 1401, MP 56.70. - Northeast Railroad Corridor, Amtrak Route between Pennsylvania/New Jersey & New Jersey/New York State Lines, Newark, Essex County, NJ

  20. 24. View looking north up corridor from Charles Street Bridge. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. View looking north up corridor from Charles Street Bridge. Providence, Providence Co., RI. Sec. 4116, mp 186.44. - Northeast Railroad Corridor, Amtrak route between CT & MA state lines, Providence, Providence County, RI

  1. Phase protection system for ac power lines

    NASA Technical Reports Server (NTRS)

    Wong, W. J. (Inventor)

    1974-01-01

    The system described provides protection for phase sensitive loads from being or remaining connected to ac power lines whenever a phase reversal occurs. It comprises a solid state phase detection circuit, a dc power relay circuit, an ac-to-dc converter for energizing the relay circuit, and a bistable four terminal transducer coupled between the phase detection circuit and the power relay circuit, for controlling both circuits.

  2. Transmission Line Adapted Analytical Power Charts Solution

    NASA Astrophysics Data System (ADS)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2016-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  3. Circuit for Communication Over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Normal F.; Greer, Lawrence C., III; Nappier, Jennifer

    2011-01-01

    Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

  4. Motor run-up system. [power lines

    NASA Technical Reports Server (NTRS)

    Daeges, J. J. (Inventor)

    1975-01-01

    A starting system is described for bringing a large synchronous motor up to speed to prevent large power line disturbances at the moment the motor is connected to the power line. The system includes (1) a digital counter which generates a count determined by the difference in frequency between the power line and a small current generated by the synchronous motor; (2) a latch which stores the count; and (3) a comparator which compares the stored count with a newly generated count to determine whether the synchronous motor is accelerating or decelerating. Signals generated by the counter and comparator control the current to a clutch that couples a starting motor to the large synchronous motor.

  5. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-221) Project #: V-O-04/10 - Paul-Allston No 1 and 2 - 500 kV Transmission Line Corridor

    SciTech Connect

    Stratton, Elaine S.

    2004-07-26

    The project activities will be conducted along the Right-of-Way (ROW) of the Paul-Allston No 1 and 2 - 500 kV transmission line corridor between towers 45/4 and the Allston substation. This corridor includes portions of the Longview-Allston No 1 and 2 and the Longview-Allston No 3 and 4 - 230 kV transmission lines. The corridor along this section of the proposed project varies between 125 and 150 feet in width and crosses approximately 4 miles of terrain from Longview, Washington crossing the Columbia River and passing through rural forestland and pasture lands to the Allston Substation in Oregon. BPA proposes to remove unwanted vegetation along the right-of-way, along access roads and around tower structures along the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation.

  6. 76 FR 71892 - Broadband Over Power Lines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ... COMMISSION 47 CFR Part 15 Broadband Over Power Lines AGENCY: Federal Communications Commission. ACTION: Final... public comment on those studies, and (3) provide a reasoned explanation of its choice of the... action addressing the court's concerns and its proposals in the RFC/FNPRM. It finds that the...

  7. Generation mechanism of power line harmonic radiation

    NASA Astrophysics Data System (ADS)

    Kostrov, Alexander; Gushchin, Mikhail; Korobkov, Sergei

    The questions concerning the generation of power line harmonic radiation (PLHR) and magne-tospheric line radiation (MLR) are discussed, including the effective source of high harmonics of 50/60 Hz, and fine dynamic structure of the frequency spectrum of PLHR and MLR. It is shown, that thyristor-based power regulators used by large electrical power consumers produce the periodic sequences of current pulses with duration of about 10 microseconds in a power line. The repetition rate of these pulses is typically 100/120 Hz; the bandwidth is as broad as 100 kHz. For high harmonics of 50/60 Hz, the power line represents an effective traveling-wave (or Beverage) antenna, especially in a frequency range of several kHz corresponding to VLF whistler band in Earth ionosphere and magnetosphere. For the fixed length of the power line, which acts as antenna, radiation directivity diagram in relation to horizon depends of frequency. Hence the spatial separation of whistlers emitted at various frequencies (1-10 kHz in a consid-ered case) is possible, with subsequent propagation of whistlers with different frequencies along different L-shells. Estimations show that the efficiency of power line as travelling-wave antenna can be changed by variations of its load, but not more than twice ("weekend effect"). Since the PLHR can represent the sequence of short electromagnetic bursts, then careful se-lection of frequency-time resolution of the data acquisition equipment is needed. Typically, the time constant of the data recording and processing is too large, and the spectra of PLHR or MLR are characterized by a well-known line structure. At the same time, original bursty structure of PLHR can not be defined. Fine structure of MLR is also discussed. Frequency drift of MLR can be explained by the perturbations of the magnetospheric plasma by intense ULF waves and particle flows affecting the propagation of PLHR. Hence the physical nature of PLHR and MLR is the same, excepting the

  8. Interaction of lightning with power distribution lines

    NASA Astrophysics Data System (ADS)

    Mata, Carlos Tomas

    Triggered-lightning experiments were conducted in 1996, 1999, and 2000 to study the responses of overhead power distribution lines to lightning at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The lightning was artificially initiated (triggered) from natural thunderclouds using the rocket-and-wire technique, and its current was directed to a phase conductor at midspan or at a pole near the center of the line. Experimental results and associated EMTP modeling are presented in this dissertation for the following line configurations: (1)a two-conductor, 740-m overhead distribution line with 2 arrester stations in 1996; (2)a four- conductor, 245-m overhead distribution line with 2 arrester stations in 1999; and (3)a four-conductor, 829-m overhead distribution line with 6 arrester stations in 2000. The three-phase lines tested in 1999 and 2000 were standard designs of a major Florida power company. Lightning peak currents injected into the lines ranged from 7 to 57 kA. Voltages and currents were measured at various locations along the line. Video and photographic cameras were used to image lightning channels and detect line flashovers. The significant results of the research are (1)flashovers between conductors were observed, both accompanied and not accompanied by arrester failures, (2)an arrester failed on seven of eight direct lightning strikes to the line in 2000, (3)arcing between conductors may prevent failures of arresters connected to the struck phase, (4)the bulk of the lightning current flows from the struck phase to neutral through the arresters closest to the strike point, (5)the withstand energy of the arresters can be exceeded due to the contribution from multiple strokes and/or relatively low-level, long-lasting current components, (6)the distribution of charge transferred to ground among multiple neutral grounds, which is determined by low-frequency, low-current grounding resistances is different from the

  9. Western Energy Corridor -- Energy Resource Report

    SciTech Connect

    Leslie Roberts; Michael Hagood

    2011-06-01

    The world is facing significant growth in energy demand over the next several decades. Strategic in meeting this demand are the world-class energy resources concentrated along the Rocky Mountains and northern plains in Canada and the U.S., informally referred to as the Western Energy Corridor (WEC). The fossil energy resources in this region are rivaled only in a very few places in the world, and the proven uranium reserves are among the world's largest. Also concentrated in this region are renewable resources contributing to wind power, hydro power, bioenergy, geothermal energy, and solar energy. Substantial existing and planned energy infrastructure, including refineries, pipelines, electrical transmission lines, and rail lines provide access to these resources.

  10. Flight route Designing and mission planning Of power line inspecting system Based On multi-sensor UAV

    NASA Astrophysics Data System (ADS)

    Xiaowei, Xie; Zhengjun, Liu; Zhiquan, Zuo

    2014-03-01

    In order to obtain various information of power facilities such as spatial location, geometry, images data and video information in the infrared and ultraviolet band and so on, Unmanned Aerial Vehicle (UAV) power line inspecting system needs to integrate a variety of sensors for data collection. Low altitude and side-looking imaging are required for UAV flight to ensure sensors to acquire high-quality data and device security. In this paper, UAV power line inspecting system is deferent from existing ones that used in Surveying and Mapping. According to characteristics of UAV for example equipped multiple sensor, side-looking imaging, working at low altitude, complex terrain conditions and corridor type flight, this paper puts forward a UAV power line inspecting scheme which comprehensively considered of the UAV performance, sensor parameters and task requirements. The scheme is finally tested in a region of Guangdong province, and the preliminary results show that the scheme is feasible.

  11. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment traveling under or near a power line on a construction site with no load. Equipment traveling on a... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  12. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment traveling under or near a power line on a construction site with no load. Equipment traveling on a... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  13. Free power dissipation from functional line integration

    NASA Astrophysics Data System (ADS)

    Brader, Joseph M.; Schmidt, Matthias

    2015-09-01

    Power functional theory provides an exact generalisation of equilibrium density functional theory to non-equilibrium systems undergoing Brownian many-body dynamics. Practical implementation of this variational approach demands knowledge of an excess (over ideal gas) dissipation functional. Using functional line integration (i.e. the operation inverse to functional differentiation), we obtain an exact expression for the excess free power dissipation, which involves the pair interaction potential and the two-body, equal-time density correlator. This provides a basis for the development of approximation schemes.

  14. Current transducers used in power line measurements

    NASA Astrophysics Data System (ADS)

    Milcarz, Sz.; Gołebiowski, J.

    2014-08-01

    There are many solutions used for current measurements in power lines. The study shows a transducer consisting of a ferromagnetic core, a beam placed in an air-gap and a sensor for optical readout. The beam is made of silicon with a thin 50%Ni50%Fe film. The material of the core is permalloy. A distribution of magnetic field depends on current supplying the power line. The beam is deflected due to magnetic field in the air-gap. A deflection of the beam is measured by the optical fibre sensor. Its advantage is simple design, high precision of processing, non-electric transmission, low costs and ability of a non-contact measurement. Comsol Multiphysics 4.4 and Magnetic Fields Module (mef) were used for modeling. An influence of magnetic circuit's materials and dimensions of the ferromagnetic core and the air-gap were tested in order to determine the most sufficient distribution of magnetic field in the air-gap. The study shows results of the modeling of the transducer compared to practical results for a similar construction scaled down to lower current values.

  15. Apparatus and Method for Communication over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, Lawrence C., III (Inventor); Nappier, Jennifer M. (Inventor)

    2015-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  16. U. H. F. Power Transistors and Lecher Line Oscillators.

    ERIC Educational Resources Information Center

    Howes, R. W.

    1980-01-01

    Describes the use of transistors instead of valves for Lecher line and radiation demonstrations. Two oscillator circuits which provide power for Lecher line use are described. Impedance of Lecher line is also discussed. (HM)

  17. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  18. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  19. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  20. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  1. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Power line carrier systems. 15.113 Section 15.113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional Radiators § 15.113 Power line carrier systems. Power line carrier systems, as defined in § 15.3(t),...

  2. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  3. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  4. Bionic Vision-Based Intelligent Power Line Inspection System

    PubMed Central

    Ma, Yunpeng; He, Feijia; Xu, Jinxin

    2017-01-01

    Detecting the threats of the external obstacles to the power lines can ensure the stability of the power system. Inspired by the attention mechanism and binocular vision of human visual system, an intelligent power line inspection system is presented in this paper. Human visual attention mechanism in this intelligent inspection system is used to detect and track power lines in image sequences according to the shape information of power lines, and the binocular visual model is used to calculate the 3D coordinate information of obstacles and power lines. In order to improve the real time and accuracy of the system, we propose a new matching strategy based on the traditional SURF algorithm. The experimental results show that the system is able to accurately locate the position of the obstacles around power lines automatically, and the designed power line inspection system is effective in complex backgrounds, and there are no missing detection instances under different conditions. PMID:28203269

  5. Bionic Vision-Based Intelligent Power Line Inspection System.

    PubMed

    Li, Qingwu; Ma, Yunpeng; He, Feijia; Xi, Shuya; Xu, Jinxin

    2017-01-01

    Detecting the threats of the external obstacles to the power lines can ensure the stability of the power system. Inspired by the attention mechanism and binocular vision of human visual system, an intelligent power line inspection system is presented in this paper. Human visual attention mechanism in this intelligent inspection system is used to detect and track power lines in image sequences according to the shape information of power lines, and the binocular visual model is used to calculate the 3D coordinate information of obstacles and power lines. In order to improve the real time and accuracy of the system, we propose a new matching strategy based on the traditional SURF algorithm. The experimental results show that the system is able to accurately locate the position of the obstacles around power lines automatically, and the designed power line inspection system is effective in complex backgrounds, and there are no missing detection instances under different conditions.

  6. 13. I95 bridge crossing corridor with Providence Station in background. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. I-95 bridge crossing corridor with Providence Station in background. Providence, Providence County, RI. sec. 4116, mp 185.15. - Northeast Railroad Corridor, Amtrak route between CT & MA state lines, Providence, Providence County, RI

  7. Satellite observations of power line harmonic radiation

    NASA Astrophysics Data System (ADS)

    Bullough, K.

    1983-06-01

    Observations of the spheric wavefield over North America, the adjacent North Atlantic, and their Southern-Hemisphere geomagnetic conjugates made with Ariel 4 are analyzed in terms of the relative influence of power-line harmonic radiation (PLHR) on wave-particle interactions affecting the earth's radiation belts. Inconsistencies in previous reports on the Sunday effect, on the starting frequencies of chorus emissions, and on the global distribution of PLHR are reviewed, and the validity of Ariel-3 and Ariel-4 findings of increased PLHR-induced emissions over the industrial areas of the US is asserted. At 9.6 kHz, the emissions over North America and the North Atlantic are characterized by almost identical spherical wavefields, while the whistler-mode signal in the Atlantic conjugate zone was found to be weaker than that in the North American conjugate; at 3.2 kHz, the sea-conjugate signal was weakened, but the land-conjugate signal was found to be identical to the land signal. It is inferred that multihop propagation permanently present over the mainland but rare over the sea is the result of duct structures which can be supported by PLHR.

  8. Acoustic power in non-uniform lined ducts

    NASA Astrophysics Data System (ADS)

    Eversman, Walter

    2008-06-01

    A definition of acoustic power in conservation form in lined infinitely long uniform ducts is extended to include axially symmetric non-uniform ducts with potential mean flow and finite length lining. The definition includes a contribution at the lined boundary. Benchmarking is accomplished by verification of acoustic power conservation in the case of a purely reactive lining. Calculations in the case of reactively lined ducts show that intense acoustic gradients near the lined surface can occur, and contributions to acoustic power from the boundary power term become relatively large. This observed behavior diminishes as the resistive component of lining impedance is increased. Power calculations for propagation and radiation from a typical turbo-fan inlet and equivalent calculations for an infinite duct propagation model of the same inlet contour are compared. Results are remarkably similar for the case considered, though it is noted that this conclusion is geometry dependent.

  9. Monitoring System of Power Line Icing Based on GPRS

    NASA Astrophysics Data System (ADS)

    Wancheng, Xie

    GPRS-based power line monitoring system for ice. The system is based on the images to monitor the power line monitoring device for ice. System through the use of simplified Sobel algorithm and Hough transform to image edge detection, with DSP high-speed computing performance and optimization of DSP code, and realized the power line ice thickness of the terminal identification and automatic alarm function; using the terminal identification means, is intelligent Monitoring of a new attempt.

  10. 2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ITS WAY TOWARD THE CEMENT MILL Photographer: Walter J. Lubken, November 19, 1907 - Roosevelt Power Canal & Diversion Dam, Parallels Salt River, Roosevelt, Gila County, AZ

  11. 24. General view looking NE up the corridor towards downtown ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. General view looking NE up the corridor towards downtown Newark with NJ State Highway ramp to Broad Street in center and Lehigh Valley Railroad Bridge in right corner. Newark, Essex Co., NJ. Sec. 1401, MP 10.35. - Northeast Railroad Corridor, Amtrak Route between Pennsylvania/New Jersey & New Jersey/New York State Lines, Newark, Essex County, NJ

  12. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  13. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  14. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  15. Effect of Power Line Interference on Microphone Calibration Measurements Made at or Near Harmonics of the Power Line Frequency.

    PubMed

    Wagner, Randall P; Nedzelnitsky, Victor

    2007-01-01

    The electrical measurements required during the primary calibrations of laboratory standard microphones by the reciprocity method can be influenced by power line interference. Because of this influence, the protocols of international inter-laboratory key comparisons of microphone calibrations usually have not included measurements at power line frequencies. Such interference has been observed in microphone output voltage measurements made with a microphone pressure reciprocity calibration system under development at NIST. This system was configured for a particular type of standard microphone in such a way that measurements of relatively small signal levels, which are more susceptible to the effect of power line interference, were required. This effect was investigated by acquiring microphone output voltage measurement data with the power line frequency adjusted to move the frequency of the interference relative to the center frequency of the measurement system passband. These data showed that the effect of power line interference for this system configuration can be more than one percent at test frequencies harmonically related to the power line frequency. These data also showed that adjusting the power line frequency to separate the interference and test frequencies by as little as 1.0 Hz can reduce the effect of the interference by at least an order of magnitude. Adjustment of the power line frequency could enable accurate measurements at test frequencies that otherwise might be avoided.

  16. Wireless power transfer and fault diagnosis of high-voltage power line via robotic bird

    NASA Astrophysics Data System (ADS)

    Liu, Chunhua; Chau, K. T.; Zhang, Zhen; Qiu, Chun; Li, Wenlong; Ching, T. W.

    2015-05-01

    This paper presents a new idea of wireless power transfer (WPT) and fault diagnosis (FD) of high-voltage power line via robotic bird. The key is to present the conceptual robotic bird with WPT coupling coil for detecting and capturing the energy from the high-voltage power line. If the power line works in normal condition, the robotic bird is able to stand on the power line and extract energy from it. If fault occurs on the power line, the corresponding magnetic field distribution will become different from that in the normal situation. By analyzing the magnetic field distribution of the power line, the WPT to the robotic bird and the FD by the robotic bird are performed and verified.

  17. An improved adaptive power line interference canceller for electrocardiography.

    PubMed

    Martens, Suzanna M M; Mischi, Massimo; Oei, S Guid; Bergmans, Jan W M

    2006-11-01

    Power line interference may severely corrupt a biomedical recording. Notch filters and adaptive cancellers have been suggested to suppress this interference. We propose an improved adaptive canceller for the reduction of the fundamental power line interference component and harmonics in electrocardiogram (ECG) recordings. The method tracks. the amplitude, phase, and frequency of all the interference components for power line frequency deviations up to about 4 Hz. A comparison is made between the performance of our method, former adaptive cancellers, and a narrow and a wide notch filter in suppressing the fundamental power line interference component. For this purpose a real ECG signal is corrupted by an artificial power line interference signal. The cleaned signal after applying all methods is compared with the original ECG signal. Our improved adaptive canceller shows a signal-to-power-line-interference ratio for the fundamental component up to 30 dB higher than that produced by the other methods. Moreover, our method is also effective for the suppression of the harmonics of the power line interference.

  18. Extraction of power lines from mobile laser scanning data

    NASA Astrophysics Data System (ADS)

    Xiang, Qing; Li, Jonathan; Wen, Chenglu; Huang, Pengdi

    2016-03-01

    Modern urban life is becoming increasingly more dependent on reliable electric power supply. Since power outages cause substantial financial losses to producers, distributors and consumers of electric power, it is in the common interest to minimize failures of power lines. In order to detect defects as early as possible and to plan efficiently the maintenance activities, distribution networks are regularly inspected. Carrying out foot patrols or climbing the structures to visually inspect transmission lines and aerial surveys (e.g., digital imaging or most recent airborne laser scanning (ALS) are the two most commonly used methods of power line inspection. Although much faster in comparison to the foot patrol inspection, aerial inspection is more expensive and usually less accurate, in complex urban areas particularly. This paper presents a scientific work that is done in the use of mobile laser scanning (MLS) point clouds for automated extraction of power lines. In the proposed method, 2D power lines are extracted using Hough transform in the projected XOY plane and the 3D power line points are visualized after the point searching. Filtering based on an elevation threshold is applied, which is combined with the vehicle's trajectory in the horizontal section.

  19. Interior, underground corridor going to building 500 from the corridor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior, underground corridor going to building 500 from the corridor connecting buildings 511 and 515. - Fitzsimons General Hospital, Infirmary, Northwest Corner of East Bushnell Avenue & South Page Street, Aurora, Adams County, CO

  20. Integrating Residential Photovoltaics With Power Lines

    NASA Technical Reports Server (NTRS)

    Borden, C. S.

    1985-01-01

    Report finds rooftop solar-cell arrays feed excess power to electric-utility grid for fee are potentially attractive large-scale application of photovoltaic technology. Presents assessment of breakeven costs of these arrays under variety of technological and economic assumptions.

  1. National Maglev initiative: California line electric utility power system requirements

    NASA Technical Reports Server (NTRS)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  2. 29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN BEND POND LABELLED 'SETTLING BASIN,' STEAM/DIESEL PLANT AND OTHER FEATURES. 1951 - Crosscut Steam Plant, North side Salt River near Mill Avenue & Washington Street, Tempe, Maricopa County, AZ

  3. Passive optical sensor for lightning detection on overhead power lines

    NASA Astrophysics Data System (ADS)

    Rosolem, J. B.; Barbosa, C. F.; Florídia, C.; Bezerra, E. L.

    2009-10-01

    In this work we present the results of a passive optical sensor for monitoring lightning strikes on overhead power lines, which can also be used for several other applications. The optic sensor is very simple and cheap and basically consists in the use of an antenna connected directly to a semiconductor laser. No batteries and solar panels are necessary to implement this sensing system in power lines towers. It was tested in laboratory and showed a good performance.

  4. Brief communication: coaxial lines for multiphase power distribution.

    PubMed

    Barnes, F S; Harwick, P; Banerjee, A

    1996-01-01

    A coaxial cable can be used to reduce the magnetic and electric fields that extend into environments in the vicinity of transmission lines and distribution lines and in-house or building wiring for power distribution systems. The use of the coaxial geometry may prove useful in cases where there are environmental concerns with respect to health effects and in cases where there is a need to run high-speed data communications in close proximity to power distribution systems.

  5. Living and Working Safely Around High-Voltage Power Lines.

    SciTech Connect

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  6. Energy harvesting from electric power lines employing the Halbach arrays.

    PubMed

    He, Wei; Li, Ping; Wen, Yumei; Zhang, Jitao; Lu, Caijiang; Yang, Aichao

    2013-10-01

    This paper proposes non-invasive energy harvesters to scavenge alternating magnetic field energy from electric power lines. The core body of a non-invasive energy harvester is a linear Halbach array, which is mounted on the free end of a piezoelectric cantilever beam. The Halbach array augments the magnetic flux density on the side of the array where the power line is placed and significantly lowers the magnetic field on the other side. Consequently, the magnetic coupling strength is enhanced and more alternating magnetic field energy from the current-carrying power line is converted into electrical energy. An analytical model is developed and the theoretical results verify the experimental results. A power of 566 μW across a 196 kΩ resistor is generated from a single wire, and a power of 897 μW across a 212 kΩ resistor is produced from a two-wire power cord carrying opposite currents at 10 A. The harvesters employing Halbach arrays for a single wire and a two-wire power cord, respectively, exhibit 3.9 and 3.2 times higher power densities than those of the harvesters employing conventional layouts of magnets. The proposed devices with strong response to the alternating currents are promising to be applied to electricity end-use environment in electric power systems.

  7. Extended optical-emission-line gas in powerful radio galaxies

    SciTech Connect

    Baum, S.A.

    1987-01-01

    Results of a search for extended optical-emission-line gas in 43 powerful radio galaxies are presented. Spatially extended optical-emission-line gas is common in these galaxies. The extent and luminosity of the emission-line gas in powerful radio galaxies is an order of magnitude greater than in normal elliptical galaxies of similar optical magnitudes. The total emission-line luminosity is roughly half of the radio luminosity, and the radio luminosity correlates with the narrow-line luminosity over four decades. The near-nuclear emission-line gas is often distributed in a smooth, roughly elliptical feature, centered on and symmetric about the nucleus. The distribution of axial ratios found in these small emission-line nebulae (ELN) is inconsistent with them being disks seen from different orientations. The minor axes of the small regions of emission-line gas show only a weak tendency to align with the position angle of the extended radio source and the major axis of the stellar isophotes. The very extended emission line gas (d{sub neb} > 10 kpc) is filamentary and is found preferentially within the regions occupied by the radio source. The small (d{sub radio} < 100 kpc) radio sources with very extended ELN show evidence of interacting with their gas-rich environments; the large (d{sub radio} > 100 kpc) radio sources with very extended ELN show no signs that they have been disturbed by their surrounding media. Lower limits to the density of the emission line gas at distances of 10 kpc from the galaxy nucleus are {approximately}0.1 cm{sup {minus}3} and upper limits to the total mass in emission line gas are {approximately}10{sup 9} M {circle dot}. The optical nuclear continuum is strongly correlated with the narrow emission line luminosity and is sufficient to photoionize the ELN.

  8. "These Power Lines Make Me Ill": A Typology of Residents' Health Responses to a New High-Voltage Power Line.

    PubMed

    Porsius, Jarry T; Claassen, Liesbeth; Woudenberg, Fred; Smid, Tjabe; Timmermans, Danielle R M

    2017-03-17

    Little attention has been devoted to the potential diversity in residents' health responses when exposed to an uncertain environmental health risk. The present study explores whether subgroups of residents respond differently to a new high-voltage power line (HVPL) being put into operation. We used a quasi-experimental prospective field study design with two pretests during the construction of a new HVPL, and two posttests after it was put into operation. Residents living nearby (0-300 m, n = 229) filled out questionnaires about their health and their perception of the environment. We applied latent class growth models to investigate heterogeneity in the belief that health complaints were caused by a power line. Classes were compared on a wide range of variables relating to negative-oriented personality traits, perceived physical and mental health, and perceptions of the environment. We identified five distinct classes of residents, of which the largest (49%) could be described as emotionally stable and healthy with weak responses to the introduction of a new power line. A considerable minority (9%) responded more strongly to the new line being activated. Residents in this class had heard more about the health effects of power lines beforehand, were more aware of the activation of the new line, and reported a decrease in perceived health afterwards. Based on our findings we can conclude that there is a considerable heterogeneity in health responses to a new HVPL. Health risk perceptions appear to play an important role in this typology, which has implications for risk management.

  9. In-line sensor for accurate rf power measurements

    NASA Astrophysics Data System (ADS)

    Gahan, D.; Hopkins, M. B.

    2005-10-01

    An in-line sensor has been constructed with 50Ω characteristic impedance to accurately measure rf power dissipated in a matched or unmatched load with a view to being implemented as a rf discharge diagnostic. The physical construction and calibration technique are presented. The design is a wide band, hybrid directional coupler/current-voltage sensor suitable for fundamental and harmonic power measurements. A comparison with a standard wattmeter using dummy load impedances shows that this in-line sensor is significantly more accurate in mismatched conditions.

  10. In-line sensor for accurate rf power measurements

    SciTech Connect

    Gahan, D.; Hopkins, M.B.

    2005-10-15

    An in-line sensor has been constructed with 50 {omega} characteristic impedance to accurately measure rf power dissipated in a matched or unmatched load with a view to being implemented as a rf discharge diagnostic. The physical construction and calibration technique are presented. The design is a wide band, hybrid directional coupler/current-voltage sensor suitable for fundamental and harmonic power measurements. A comparison with a standard wattmeter using dummy load impedances shows that this in-line sensor is significantly more accurate in mismatched conditions.

  11. Development of on-line laser power monitoring system

    NASA Astrophysics Data System (ADS)

    Ding, Chien-Fang; Lee, Meng-Shiou; Li, Kuan-Ming

    2016-03-01

    Since the laser was invented, laser has been applied in many fields such as material processing, communication, measurement, biomedical engineering, defense industries and etc. Laser power is an important parameter in laser material processing, i.e. laser cutting, and laser drilling. However, the laser power is easily affected by the environment temperature, we tend to monitor the laser power status, ensuring there is an effective material processing. Besides, the response time of current laser power meters is too long, they cannot measure laser power accurately in a short time. To be more precisely, we can know the status of laser power and help us to achieve an effective material processing at the same time. To monitor the laser power, this study utilize a CMOS (Complementary metal-oxide-semiconductor) camera to develop an on-line laser power monitoring system. The CMOS camera captures images of incident laser beam after it is split and attenuated by beam splitter and neutral density filter. By comparing the average brightness of the beam spots and measurement results from laser power meter, laser power can be estimated. Under continuous measuring mode, the average measuring error is about 3%, and the response time is at least 3.6 second shorter than thermopile power meters; under trigger measuring mode which enables the CMOS camera to synchronize with intermittent laser output, the average measuring error is less than 3%, and the shortest response time is 20 millisecond.

  12. Fast wave power flow along SOL field lines in NSTX

    NASA Astrophysics Data System (ADS)

    Perkins, R. J.; Bell, R. E.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; Leblanc, B. P.; Kramer, G. J.; Phillips, C. K.; Roquemore, L.; Taylor, G.; Wilson, J. R.; Ahn, J.-W.; Gray, T. K.; Green, D. L.; McLean, A.; Maingi, R.; Ryan, P. M.; Jaeger, E. F.; Sabbagh, S.

    2012-10-01

    On NSTX, a major loss of high-harmonic fast wave (HHFW) power can occur along open field lines passing in front of the antenna over the width of the scrape-off layer (SOL). Up to 60% of the RF power can be lost and at least partially deposited in bright spirals on the divertor floor and ceiling [1,2]. The flow of HHFW power from the antenna region to the divertor is mostly aligned along the SOL magnetic field [3], which explains the pattern of heat deposition as measured with infrared (IR) cameras. By tracing field lines from the divertor back to the midplane, the IR data can be used to estimate the profile of HHFW power coupled to SOL field lines. We hypothesize that surface waves are being excited in the SOL, and these results should benchmark advanced simulations of the RF power deposition in the SOL (e.g., [4]). Minimizing this loss is critical optimal high-power long-pulse ICRF heating on ITER while guarding against excessive divertor erosion.[4pt] [1] J.C. Hosea et al., AIP Conf Proceedings 1187 (2009) 105. [0pt] [2] G. Taylor et al., Phys. Plasmas 17 (2010) 056114. [0pt] [3] R.J. Perkins et al., to appear in Phys. Rev. Lett. [0pt] [4] D.L. Green et al., Phys. Rev. Lett. 107 (2011) 145001.

  13. Long Island Smart Energy Corridor

    SciTech Connect

    Mui, Ming

    2015-02-04

    The Long Island Power Authority (LIPA) has teamed with Stony Brook University (Stony Brook or SBU) and Farmingdale State College (Farmingdale or FSC), two branches of the State University of New York (SUNY), to create a “Smart Energy Corridor.” The project, located along the Route 110 business corridor on Long Island, New York, demonstrated the integration of a suite of Smart Grid technologies from substations to end-use loads. The Smart Energy Corridor Project included the following key features: -TECHNOLOGY: Demonstrated a full range of smart energy technologies, including substations and distribution feeder automation, fiber and radio communications backbone, advanced metering infrastructure (AM”), meter data management (MDM) system (which LIPA implemented outside of this project), field tools automation, customer-level energy management including automated energy management systems, and integration with distributed generation and plug-in hybrid electric vehicles. -MARKETING: A rigorous market test that identified customer response to an alternative time-of-use pricing plan and varying levels of information and analytical support. -CYBER SECURITY: Tested cyber security vulnerabilities in Smart Grid hardware, network, and application layers. Developed recommendations for policies, procedures, and technical controls to prevent or foil cyber-attacks and to harden the Smart Grid infrastructure. -RELIABILITY: Leveraged new Smart Grid-enabled data to increase system efficiency and reliability. Developed enhanced load forecasting, phase balancing, and voltage control techniques designed to work hand-in-hand with the Smart Grid technologies. -OUTREACH: Implemented public outreach and educational initiatives that were linked directly to the demonstration of Smart Grid technologies, tools, techniques, and system configurations. This included creation of full-scale operating models demonstrating application of Smart Grid technologies in business and residential

  14. Line bisection task performance and resting EEG alpha power.

    PubMed

    Ciçek, Metehan; Nalçaci, Erhan; Kalaycioglu, Canan

    2003-06-01

    Neurologically normal subjects generally err to the left of veridical center when performing a line bisection task, a phenomenon termed "pseudoneglect." We hypothesized that resting electroencephalogram (EEG) alpha oscillations may show relationships with attentional mechanisms and give some clues about the underlying mechanisms of pseudoneglect. We recorded resting EEGs of 41 subjects and tested them with a paper-pencil line bisection task. Our results showed that line bisection scores of men (n=18) were less biased and their performance was higher compared to those of women (n=20), but these differences only approached significance. The eyes open resting EEG alpha power of women was significantly and positively correlated with their line bisection performance. In general, significant relationships were related to the left hand performance when the lines were presented in the left hemispace. Greater resting alpha power was correlated with lower absolute bisection score or, in other words, higher bisection performance. Greater alpha power also correlated with diminished leftward bisection bias (or reduced pseudo-neglect). The resting EEG alpha of men was weakly associated with bisection performance. Results discussed in terms of Kinsbourne's activation-orientation theory and Basar's view on brain oscillations.

  15. Limiting electric fields of HVDC overhead power lines.

    PubMed

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  16. Power line carrier interference from HVDC converter terminals

    SciTech Connect

    Tatro, P.J.; Adamson, K.A. ); Eitzmann, M.A.; Smead, M. . Power Systems Engineering Dept.)

    1993-07-01

    Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

  17. Corridor use by diverse taxa.

    SciTech Connect

    Haddad, Nick, M.; Browne, David, R.; Cunningham, Alan; Danielson, Brent, J.; Levey, Douglas, J.; Sargent, Sarah; Spira, Tim

    2003-01-01

    Haddad, N.M., D.R. Browne, A. Cunningham, B.J. Danielson, D.J. Levey, S. Sargent, and T. Spira. 2003. Corridor use by diverse taxa. Ecology, 84(3):609-615. One of the most popular approaches for maintaining populations and conserving biodiversity in fragmented landscapes is to retain or create corridors that connect otherwise isolated habitat patches. Working in large-scale, experimental landscapes in which open-habitat patches and corridors were created by harvesting pine forest, we showed that corridors direct movements of different types of species, including butterflies, small mammals, and bird dispersed plants, causing higher movement between connected than between unconnected patches. Corridors directed the movement of all 10 species studied, with all corridor effect sizes >68%. However, this corridor effect was significant for five species, not significant for one species, and inconclusive for four species because of small sample sizes. Although we found no evidence that corridors increase emigration from a patch, our results show that movements of disparate taxa with broadly different life histories and functional roles are directed by corridors.

  18. El Paso Electric Company Diablo Substation to the US-Mexico border 115kV transmission line project. Final Environmental Assessment

    SciTech Connect

    Not Available

    1992-04-01

    This Environmental Assessment documents the analysis of alternative corridors for development and operation of a proposed 115 kilovolt transmission line using private lands and transporting power to the US-Mexico international border. The project will require (1) an amendment to El Paso Electric Company`s existing export authorization to transfer power across this border, and (2) a Presidential Permit for construction of the transmission line. The project would be located in Dona Ana county in southern New Mexico, approximately five miles west of El Paso, Texas. The alternative corridors, specific locations within those corridors, and structure types are identified and analyzed in the environmental studies.

  19. 24. Interior view of entrance corridor looking down east corridor; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Interior view of entrance corridor looking down east corridor; showing unoccupied corner office space and stairs going down to lower floor; center of main section of building on main floor; view to northeast. - Ellsworth Air Force Base, Group Administration & Secure Storage Building, 2372 Westover Avenue, Blackhawk, Meade County, SD

  20. Power Line Carrier Techniques Applied to Spacecraft Data Handling

    NASA Astrophysics Data System (ADS)

    Bedu, J.-Y.; Morisse, J.; Auvergne, X.; Plancke, P.

    Power Line Carrier (PLC) data transmission coupled with spread spectrum technique is evaluated for onboard satellite purpose. Power Line Carrier present a great advantage in terms of mass saving and integration cost by suppressing the data bus harness. Spread Spectrum techniques allows data transmission inside the power supply noise. This paper will address the major functionality keys of this transmission method and will define the main trades off to conduct. INTRODUCTION A major trend for the next satellite generation stands in the increase of the equipment unit's quantity, of their complexity and of their communication needs. A first approach to reduce the number of links and also the overall mass stands in multiplexing Acq/Ctr on data bus. ALCATEL SPACE with its so-called new avionics 4000 has made a significant step with an intensive use of the data bus : round 140 units on its proprietary OBDH-485 bus and round 10 units on the MIL-STD-1553 data bus for Telecom Geostationnary satellite class. According to this state of the art, the following step is the suppression of the data bus harness by means of Wireless or Power Line Carrier (PLC) techniques that has been identified as a development axis. Many PLC components are available for domestic/industry applications. Nevertheless, transmission levels, operating frequencies, radiation hardening performances of these parts are usually not compatible with space environment constraints. 2/12

  1. Raptor electrocution on power lines: Current issues and outlook

    USGS Publications Warehouse

    Lehman, Robert N.

    2001-01-01

    Electrocution on power lines is one of many human-caused mortality factors that affect raptors. Cost-effective and relatively simple raptor-safe standards for power line modification and construction have been available for over 25 years. During the 1970s and early 1980s, electric industry efforts to reduce raptor electrocutions were very coordinated and proactive, but predictions about resolving the problem were overly optimistic. Today, raptors continue to be electrocuted, possibly in large numbers. The electrocution problem has not been resolved, partly because of the sheer number of potentially lethal power poles in use and partly because electrocution risks may be more pervasive and sometimes less conspicuous than once believed. Also, responses to the problem by individual utilities have not been uniform, and deregulation of the electric industry during the 1990s may have deflected attention from electrocution issues. To control raptor electrocutions in the future, the industry must increase information sharing and technology transfer, increase efforts to retrofit lethal power poles, and above all ensure that every new and replacement line constructed incorporates raptor-safe standards at all phases of development. Finally, responsibility for the electrocution problem must be shared. Federal, state, and local governments, academic institutions, the conservation community, and the consumer all can play critical roles in an effort that will, by necessity, extend well into the new century.

  2. Modelling of power lines in lightning incidence calculations

    SciTech Connect

    Mousa, A.M. ); Srivastava, K.D. )

    1990-01-01

    When applying the electrogeometric model to power lines to determine the frequency and characteristics of the collected lightning strokes, the power line has traditionally been represented by a set of horizontal wires, i.e. both the sag of the wires and the existence of the towers have been ignored. This approach has serious shortcomings including inability to determine the percentage of the strokes terminating on the towers, failure to correctly predict the effect of height on median current, and giving an approximate value for the number of collected strokes without telling the corresponding degree of error. This paper eliminates the above problems by presenting a computerized solution which takes into consideration the sag of the wires, the existence of the towers, and the inequality of the striking distances to towers and to wires. The features of the program are discussed in the paper, and some of its results are given.

  3. Power transmission line operating modes calculation with controllable phase shifters

    NASA Astrophysics Data System (ADS)

    Astashev, M. G.; Novikov, M. A.; Panfilov, D. I.; Rashitov, P. A.; Remizevich, T. V.; Fedorova, M. I.

    2016-12-01

    The article contains the analysis of the influence of the phase shifter (PS) on the energy processes in the power transmission line in terms of the two-unit model of the electric network. The approach to synthesis of the models regulated by the phase shifter providing for both calculation of the steady operation modes of the electric networks with the phase shifters and research of the electromagnetic processes and designing of the device itself is offered.

  4. Analysis of a high power microwave radial line slot antenna.

    PubMed

    Peng, Shengren; Yuan, Chengwei; Shu, Ting

    2013-07-01

    A traditional radial line slot antenna (RLSA) is a high gain planar array. To improve the power handling capacity, we design a radial line slow wave structure which replaces a traditional dielectric sheet in the radial waveguide of the traditional RLSA. This high power microwave (HPM) RLSA is fed from a double-layered radial line waveguide to realize the directional radiation of the microwave. However, the track of the widen slot array on the upper waveguide could cause large reflection, which disturbs the normal antenna operation, accordingly a reflection canceling slot is added to the lower waveguide, the key technology employed in the design of the HPM RLSA and the antenna return-loss is effectively improved. This article mainly gives the design theory of this antenna, which is confirmed by the simulations and experiments. At 9.4 GHz, the calculated aperture efficiency reaches more than 40%, the reflectance is less than 0.1, the radiation efficiency is more than 99% and its measured power-handling capacity exceeds 700 MW.

  5. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  6. Estimating magnetic fields of homes near transmission lines in the California Power Line Study.

    PubMed

    Vergara, Ximena P; Kavet, Robert; Crespi, Catherine M; Hooper, Chris; Silva, J Michael; Kheifets, Leeka

    2015-07-01

    The California Power Line Study is a case-control study investigating the relation between residences near transmission lines and risk of childhood leukemia. It includes 5788 childhood leukemia cases and 5788 matched primary controls born between 1986 and 2007. We describe the methodology for estimating magnetic fields at study residences as well as for characterizing sources of uncertainty in these estimates. Birth residences of study subjects were geocoded and their distances to transmission lines were ascertained. 302 residences were deemed sufficiently close to transmission lines to have non-zero magnetic fields attributable to the lines. These residences were visited and detailed data, describing the physical configuration and dimensions of the lines contributing to the magnetic field at the residence, were collected. Phasing, loading, and directional load flow data for years of birth and diagnosis for each subject as well as for the day of site visit were obtained from utilities when available; when yearly average load for a particular year was not available, extrapolated values based on expert knowledge and prediction models were obtained. These data were used to estimate the magnetic fields at the center, closest and farthest point of each residence. We found good correlation between calculated fields and spot measurements of fields taken on site during visits. Our modeling strategies yielded similar calculated field estimates, and they were in high agreement with utility extrapolations. Phasing was known for over 90% of the lines. Important sources of uncertainty included a lack of information on the precise location of residences located within apartment buildings or other complexes. Our findings suggest that we were able to achieve high specificity in exposure assessment, which is essential for examining the association between distance to or magnetic fields from power lines and childhood leukemia risk.

  7. Corridors cause differential seed predation.

    SciTech Connect

    Orrock, John L.; Damschen, Ellen I.

    2005-06-01

    Orrock, John, L., and Ellen I. Damschen. 2005. Corridors cause differential seed predation. Ecol. Apps. 15(3):793-798. Abstract. Corridors that connect disjunct populations are heavily debated in conservation, largely because the effects of corridors have rarely been evaluated by replicated, large-scale studies. Using large-scale experimental landscapes, we found that, in addition to documented positive effects, corridors also have negative impacts on bird-dispersed plants by affecting seed predation, and that overall predation is a function of the seeds primary consumer (rodents or arthropods). Both large-seeded Prunus serotina and small-seeded Rubus allegheniensis experienced greater predation in connected patches. However, P. serotina experienced significantly less seed predation compared to R. allegheniensis in unconnected patches, due to decreased impacts of rodent seed predators on this large-seeded species. Viewed in light of previous evidence that corridors have beneficial impacts by increasing pollination and seed dispersal, this work demonstrates that corridors may have both positive and negative effects for the same plant species at different life stages. Moreover, these effects may differentially affect plant species within the same community: seeds primarily consumed by rodents suffer less predation in unconnected patches. By shifting the impact of rodent and arthropod seed predators, corridors constructed for plant conservation could lead to shifts in the seed bank.

  8. Power line harmonic radiation: A systematic study using DEMETER spacecraft

    NASA Astrophysics Data System (ADS)

    Němec, F.; Santolík, O.; Parrot, M.; Berthelier, J. J.

    We present results of a systematic survey of Power line harmonic radiation (PLHR) observed by the DEMETER spacecraft. DEMETER is a French micro-satellite launched in June, 2004 with an altitude of orbit of about 700 km. It is designed specifically to study electromagnetic effects connected with seismic and man-made activity. All available high-resolution burst-mode electromagnetic data measured since the beginning of the mission till July 2006 (altogether about 1650 h of data) have been analyzed using an automatic identification procedure. This procedure was specially developed to search for emissions of PLHR type. It is running in DEMETER control center in Orléans, France. 49 PLHR events with frequency spacing of 50/100 or 60/120 Hz have been found, allowing us to perform a statistical study of properties of PLHR. It is shown that for all the events, the observed frequency spacing corresponds well to the power system frequency at anticipated source locations. Moreover, the frequency of the observed lines often (80%) corresponds to the exact harmonics of the power system base frequency. Finally, the most intense events are observed at lower frequencies and no weak events are observed under geomagnetically disturbed conditions.

  9. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    PubMed

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  10. Predicted Performances of Power Line Communication in Aircraft

    NASA Astrophysics Data System (ADS)

    Degardin, V.; Junqua, I.; Lienard, M.; Degauque, P.; Bertuol, S.; Genoulaz, J.; Dunand, M.

    2012-05-01

    The possibility of using power line communication to transmit information in a large aircraft is studied. The communication link, which has been identified and chosen in the frame of the TAUPE European project, is the cabin lighting system since its tree shape and large structure allows covering most of the other possible applications. A statistical theoretical analysis, based on the multiconductor transmission line theory, has been carried out to determine the properties of the channel transfer function. This has been done in two steps: First a simplified network was considered to outline the parameters of the network geometry playing an important role on the path loss, and then by modelling a test bench which will be used as a demonstrator. The PLC link has been modelled for predicting data rate and bit error rate, taking the EMC constraints into account.

  11. Trend on High-speed Power Line Communication Technology

    NASA Astrophysics Data System (ADS)

    Ogawa, Osamu

    High-speed power line communication (PLC) is useful technology to easily build the communication networks, because construction of new infrastructure is not necessary. In Europe and America, PLC has been used for broadband networks since the beginning of 21th century. In Japan, high-speed PLC was deregulated only indoor usage in 2006. Afterward it has been widely used for home area network, LAN in hotels and school buildings and so on. And recently, PLC is greatly concerned as communication technology for smart grid network. In this paper, the author surveys the high-speed PLC technology and its current status.

  12. Power Line Communication (PLC) in Space - Current Status and Outlook

    NASA Astrophysics Data System (ADS)

    Wolf, J.

    2012-05-01

    The Power Line Communication (PLC) technology as known from various terrestrial applications, e.g. in building automation, in the automotive sector and on aircraft, appears to be a promising technology for the use on spacecraft. Starting from a critical overview on existing terrestrial PLC applications with their pros and cons, the paper gives a motivation for the introduction of the PLC technology on spacecraft, discusses the potential areas where it can be applied and is highlighting the potential problem areas. A short overview of on-going ESA PLC activities is provided and an outlook is given.

  13. Investigation into the Effects of Microsecond Power Line Transients on Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, K.

    2000-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage ratings needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations. and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  14. Investigation Into The Effects of Microsecond Power Line Transients On Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, Ken

    1999-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage rating needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  15. China-Pakistan Economic Corridor.

    SciTech Connect

    Boyce, Tucker

    2017-01-01

    International trade and related economic activities in Central and South Asia are increasing as developing economies, particularly India and Pakistan, grow. China continues to emerge as a major regional and global power and has embarked upon numerous regional economic and political initiatives . A major development is the China - Pakistan Economic Corridor (CPEC), a host of infrastructure and trade projects worth over 40 billion American dollars . This report analyzes CPEC a nd its potential regional effects, including the trade security implications of the port and land infrastructure developments . As trade increase s in the reg ion and the major CPEC infrastructure projects are completed, there will be numerous implications on trade security and geopolitics within South Asia. CPEC projects uniquely intersect numerous regional situations, including territorial disputes in Kashmir, the Afghanistan/Pakistan border, and Chinese foreign policy a mbitions. A nuanced understanding of these effects can influence future policy adjustments in this region . The views expressed in this report are those of the author and do not necessarily reflect the position of Sandia National Laboratories or the author's current and past institutions.

  16. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  17. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  18. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  19. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  20. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  1. A Line Weighted Frequency Droop Controller for Decentralized Enforcement of Transmission Line Power Flow Constraints in Inverter-Based Networks

    SciTech Connect

    Ainsworth, Nathan G; Grijalva, Prof. Santiago

    2013-01-01

    Recent works have shown that networks of voltagesource inverters implementing frequency droop control may be analyzed as consensus-like networks. Based on this understanding, we show that enforcement of network line power flows can be viewed as an edge-preservation problem in a -disk dynamic interaction graph. Inspired by other works solving similar problems in other domains, we propose a line weighted frequency droop controller such that a network of all active buses implementing this controller enforces the specified line power flow constraints without need for communication. We provide simulation results verifying that our proposed controller limits line power to enforce constraints, and otherwise acts as a traditional droop controller.

  2. Analysis of Potential Energy Corridors Proposed by the Western Electricity Coordinating Council

    SciTech Connect

    Kuiper, James A.; Cantwell, Brian J.; Hlava, Kevin J.; Moore, H Robert; Orr, Andrew B.; Zvolanek, Emily A.

    2014-02-24

    analyze the proposed energy corridors in the WECC report in five topic areas: Federal land jurisdiction, Existing Section 368 corridors, Existing transmission lines, Previously studied corridor locations, and Protected areas. Analysis methods are explained and tables and maps are provided to describe the results of the analyses in all five topic areas. WECC used a rational approach to connecting the hubs it identified, although there may be opportunities for adapting some of the proposed WECC routes to previously designated Section 368 corridors, for example: The WECC proposed energy corridors are in fact centerlines of proposed routes connecting hubs of various descriptions related to electric energy transmission. Although the centerlines were sited to avoid sensitive areas, infrastructure proposed within actual pathways or corridors defined by the centerlines would sometimes affect lands where such development would not normally be allowed, such as National Parks and Monuments, National Wildlife Refuges, and Wilderness Areas. Many WECC proposed energy corridors are sited along centerlines of existing roads, including Interstate Highways, where in some cases additional width to accommodate energy transmission infrastructure may not be available. Examples include the WECC Proposed Corridor along Interstate 70 through Glenwood Canyon in Colorado, and along U.S. Highway 89 across Glen Canyon Dam in Arizona. Several WECC proposed energy corridors are parallel to designated Section 368 corridors that have already cleared the preliminary steps to right-of-way approval. In many of these cases, the WECC hub connection objectives can be met more efficiently by routing on the designated Section 368 corridors.

  3. Strategy for the Identification of an INL Comprehensive Utility Corridor

    SciTech Connect

    John Reisenauer

    2011-05-01

    This report documents the strategy developed to identify a comprehensive utility corridor (CUC) on the Idaho National Laboratory (INL) Site. The strategy established the process for which the Campus Development Office will evaluate land management issues. It is a process that uses geographical information system geospatial technology to layer critical INL mission information in a way that thorough evaluations can be conducted and strategies developed. The objective of the CUC Project was to develop a process that could be implemented to identify potential utility corridor options for consideration. The process had to take into account all the missions occurring on the INL and other land-related issues. The process for developing a CUC strategy consists of the following four basic elements using geographical information system capabilities: 1. Development of an INL base layer map; this base layer map geospatially references all stationary geographical features on INL and sitewide information. 2. Development of current and future mission land-use need maps; this involved working with each directorate to identify current mission land use needs and future land use needs that project 30 years into the future. 3. Development of restricted and potential constraint maps; this included geospatially mapping areas such as wells, contaminated areas, firing ranges, cultural areas, ecological areas, hunting areas, easement, and grazing areas. 4. Development of state highway and power line rights of way map; this included geospatially mapping rights-of-way along existing state highways and power lines running through the INL that support INL operations. It was determined after completing and evaluating the geospatial information that the area with the least impact to INL missions was around the perimeter of the INL Site. Option 1, in this document, identifies this perimeter; however, it does not mean the entire perimeter is viable. Many places along the perimeter corridor cannot

  4. Corridor use by Asian elephants.

    PubMed

    Pan, Wenjing; Lin, Liu; Luo, Aidong; Zhang, Li

    2009-06-01

    There are 18 km of Kunming-Bangkok Highway passing through the Mengyang Nature Reserve of Xishuangbanna National Nature Reserve in Yunnan Province, China. From September 2005 to September 2006 the impact of this highway on movement of wild Asian elephants between the eastern and western part of the nature reserve was studied using track transecting, rural surveys and direct monitoring. Our results showed that the number of crossroad corridors used by Asian elephants diminished from 28 to 23 following the construction of the highway. In some areas, the elephant activity diminished or even disappeared, which indicated a change in their home ranges. The utilization rate of artificial corridors was 44%. We also found that elephants preferred artificial corridors that were placed along their original corridors. During the research, wild elephants revealed their adaptation to the highway. They were found walking across the highway road surface many times and for different reasons. We suggest that the highway management bureau should revise their management strategies to mitigate the potential risks caused by elephants on the road for the safety of the public and to protect this endangered species from harm. It is also very important to protect and maintain current Asian elephants corridors in this region.

  5. New live line tester for porcelain suspension insulators on high-voltage power lines

    SciTech Connect

    Vaillancourt, G.H.; St-Jean, M. ); Bellerive, J.P. ); Jean, C. )

    1994-01-01

    Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

  6. Biological effects of power line fields: New York State Power Lines Project Scientific Advisory Panel: Final report

    SciTech Connect

    Ahlbom, A.; Albert, E.N.; Fraser-Smith, A.C.; Grodzinsky, A.J.; Marron, M.T.; Martin, A.O.; Persinger, M.A.; Shelanski, M.L.; Wolpow, E.R.

    1987-07-01

    The New York State Power Lines Project was established to conduct research and to review the scientific literature to determine whether health hazards of electric and magnetic fields are possible. Particular attention was directed to the fields generated by 765-kV overhead transmission lines. The research program provided support to 16 research groups studying human, animal and isolated cell sensitivity to electric and magnetic fields. No effects were found on reproduction, growth or development. Several studies showed no evidence of genetic or chromosomal damage that might lead to inherited effects or cause cancer. While most measurements of behavior and brain function did not demonstrate changes, some did show changes that were small but consistent. Some of these appear to result from changes in body rhythms, and might interfere with normal sleep patterns. There were also changes in pain responses and in the ability of rats to learn. A more serious concern comes from a study of cancer in children suggesting that children with leukemia and brain cancer are more likely to live in homes where there are elevated 60-Hz magnetic field levels. Although much more research is needed before the question whether the magnetic fields actually cause or promote cancer can be resolved, the basis for such an hypothesis is now established. 159 refs., 12 figs., 7 tabs.

  7. 78 FR 76140 - Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line Project Draft... Hudson Power Express Transmission Line Project Draft Environmental Impact Statement (DOE/EIS-0447). The... permit to the Applicant, Champlain Hudson Power Express, Inc. (CHPEI), to construct, operate,...

  8. Power Lines and Crops Can Be Good Neighbors

    SciTech Connect

    2010-08-01

    Two of the Pacific Northwest’s greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the region’s farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration — which owns and operates three-quarters of the region’s high-voltage transmission — recognizes the importance of our region’s agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our region’s electricity system. By working together, BPA and landowners can protect the system and public safety.

  9. Measurements of Impedance and Attenuation at CENELEC Bands for Power Line Communications Systems

    PubMed Central

    Cavdar, I. Hakki; Karadeniz, Engin

    2008-01-01

    Power line impedance is a very important parameter on the design of power line communications (PLC) modem architecture. Variations on the impedance of the power line affect the communications circuit performance. In order to determine impedance of the power lines, measurements were carried out in Turkey at frequencies ranging from 10 to 170 kHz, (CENELEC A,B,C,D bands). Measurements were conducted in three categories: rural, urban and the industrial power lines. Experimental results are presented in graphical form. The measured impedances were determined as 3-17 ohms, 1-17 ohms, and 1-21 ohms for rural, urban and the industrial lines, respectively. A set of the formulas between impedance and frequency are developed on the power lines using the regression analysis from the obtained empirical data. Signal attenuations on the power lines in the CENELEC band are also measured for rural, urban and industrial regions. Attenuation measurements are repeated for phase-neutral, phase-ground and the neutral-ground conductors. Signal attenuations are found to be 4-30 dB, for different power lines. To establish validity of obtained results for the design of PLC systems, the results are compared with previous investigations. The effects of some household appliances such as TV, PC, UPS, lighting and cooling systems on the impedances and the attenuations for power line communications systems are observed. Some suggestions and proposals are presented for PLC modem designers. PMID:27873974

  10. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid

    PubMed Central

    Byambasuren, Bat-erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-01-01

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274

  11. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.

    PubMed

    Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-02-19

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.

  12. [The realization of tracking power-line interference adaptive coherent model base on part FFT].

    PubMed

    Yu, Chao; Li, Gang; Lin, Ling

    2007-08-01

    Adaptive coherent model can be easily implemented and it can simultaneously reject the power-line interference and baseline wander. But the relevancy of the filter's bandwidth at low-frequency and power-line interference limits its application on ECG filtering. A part fast Fourier transform (FFT) algorithm is presented. It is used to track power-line frequency and adjust the sample frequency. Experiments show that the method still rejects interference efficiently despite of the slow fluctuation of power-line frequency.

  13. a Meteorological Risk Assessment Method for Power Lines Based on GIS and Multi-Sensor Integration

    NASA Astrophysics Data System (ADS)

    Lin, Zhiyong; Xu, Zhimin

    2016-06-01

    Power lines, exposed in the natural environment, are vulnerable to various kinds of meteorological factors. Traditional research mainly deals with the influence of a single meteorological condition on the power line, which lacks of comprehensive effects evaluation and analysis of the multiple meteorological factors. In this paper, we use multiple meteorological monitoring data obtained by multi-sensors to implement the meteorological risk assessment and early warning of power lines. Firstly, we generate meteorological raster map from discrete meteorological monitoring data using spatial interpolation. Secondly, the expert scoring based analytic hierarchy process is used to compute the power line risk index of all kinds of meteorological conditions and establish the mathematical model of meteorological risk. By adopting this model in raster calculator of ArcGIS, we will have a raster map showing overall meteorological risks for power line. Finally, by overlaying the power line buffer layer to that raster map, we will get to know the exact risk index around a certain part of power line, which will provide significant guidance for power line risk management. In the experiment, based on five kinds of observation data gathered from meteorological stations in Guizhou Province of China, including wind, lightning, rain, ice, temperature, we carry on the meteorological risk analysis for the real power lines, and experimental results have proved the feasibility and validity of our proposed method.

  14. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  15. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  16. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  17. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  18. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  19. Risk of hematological malignancies associated with magnetic fields exposure from power lines: a case-control study in two municipalities of northern Italy

    PubMed Central

    2010-01-01

    Background Some epidemiologic studies have suggested an association between electromagnetic field exposure induced by high voltage power lines and childhood leukemia, but null results have also been yielded and the possibility of bias due to unmeasured confounders has been suggested. Methods We studied this relation in the Modena and Reggio Emilia municipalities of northern Italy, identifying the corridors along high voltage power lines with calculated magnetic field intensity in the 0.1-<0.2, 0.2-<0.4, and ≥ 0.4 microTesla ranges. We identified 64 cases of newly-diagnosed hematological malignancies in children aged <14 within these municipalities from 1986 to 2007, and we sampled four matched controls for each case, collecting information on historical residence and parental socioeconomic status of these subjects. Results Relative risk of leukemia associated with antecedent residence in the area with exposure ≥ 0.1 microTesla was 3.2 (6.7 adjusting for socioeconomic status), but this estimate was statistically very unstable, its 95% confidence interval being 0.4-23.4, and no indication of a dose-response relation emerged. Relative risk for acute lymphoblastic leukemia was 5.3 (95% confidence interval 0.7-43.5), while there was no increased risk for the other hematological malignancies. Conclusions Though the number of exposed children in this study was too low to allow firm conclusions, results were more suggestive of an excess risk of leukemia among exposed children than of a null relation. PMID:20353586

  20. Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

    SciTech Connect

    Hutsel, Brian Thomas; Stoltzfus, Brian S.; Fowler, William E.; LeChien, Keith R.; Mazarakis, Michael G.; Moore, James K.; Mulville, Thomas D.; Savage, Mark E.; Stygar, William A.; McKenney, John L.; Jones, Peter A.; MacRunnels, Diego J.; Long, Finis W.; Porter, John L.

    2014-09-01

    An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

  1. HANFORD SITE RIVER CORRIDOR CLEANUP

    SciTech Connect

    BAZZELL, K.D.

    2006-02-01

    In 2005, the US Department of Energy (DOE) launched the third generation of closure contracts, including the River Corridor Closure (RCC) Contract at Hanford. Over the past decade, significant progress has been made on cleaning up the river shore that bordes Hanford. However, the most important cleanup challenges lie ahead. In March 2005, DOE awarded the Hanford River Corridor Closure Contract to Washington Closure Hanford (WCH), a limited liability company owned by Washington Group International, Bechtel National and CH2M HILL. It is a single-purpose company whose goal is to safely and efficiently accelerate cleanup in the 544 km{sup 2} Hanford river corridor and reduce or eliminate future obligations to DOE for maintaining long-term stewardship over the site. The RCC Contract is a cost-plus-incentive-fee closure contract, which incentivizes the contractor to reduce cost and accelerate the schedule. At $1.9 billion and seven years, WCH has accelerated cleaning up Hanford's river corridor significantly compared to the $3.2 billion and 10 years originally estimated by the US Army Corps of Engineers. Predictable funding is one of the key features of the new contract, with funding set by contract at $183 million in fiscal year (FY) 2006 and peaking at $387 million in FY2012. Another feature of the contract allows for Washington Closure to perform up to 40% of the value of the contract and subcontract the balance. One of the major challenges in the next few years will be to identify and qualify sufficient subcontractors to meet the goal.

  2. 77 FR 38793 - Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... Energy Regulatory Commission Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain Rural Electric Association, Tri-State Generation and Transmission Association, Inc. v. Public... CFR 385.206 and 385.212 (2011), Grand Valley Rural Power Lines, Inc., Yampa Valley...

  3. Research of Characteristics of the Low Voltage Power Line in Underground Coal Mine

    NASA Astrophysics Data System (ADS)

    Wei, Shaoliang; Qin, Shiqun; Gao, Wenchang; Cheng, Fengyu; Cao, Zhongyue

    The power line communications (PLCs) can count on existing electrical connections reaching each corner in the locations where such applications are required, so signal transmission over power lines is nowadays gaining more and more interest for applications like internet. The research of characteristics of the low voltage power line is the fundamental and importance task. This work presents a device to test the characteristics of the low voltage power line. The low voltage power line channel characteristics overground and the channel characteristics underground were tested in using this device. Experiments show that, the characteristics are different between the PLCs channel underground coal mine and the PLC channel overground. Different technology should be adopted to structure the PLCs channel model underground coal mine and transmit high speed digital signal. But how to use the technology better to the high-speed digital communication under coal mine is worth of further studying.

  4. Power Law Subordinacy and Singular Spectra.II. Line Operators

    NASA Astrophysics Data System (ADS)

    Jitomirskaya, Svetlana Ya.; Last, Yoram

    We study Hausdorff-dimensional spectral properties of certain ``whole-line'' quasiperiodic discrete Schrödinger operators by using the extension of the Gilbert-Pearson subordinacy theory that we previously developed in [19].

  5. How Corridors Reduce Indigo Bunting Nest Success.

    SciTech Connect

    Weldon, Aimee, J.

    2006-08-01

    Abstract: Corridors are a popular strategy to conserve biodiversity and promote gene flow in fragmented landscapes. Corridor effectiveness has been bolstered by the fact that no empirical field studies have shown negative effects on populations or communities. I tested the hypothesis that corridors increase nest predation in connected habitat fragments relative to unconnected fragments. I evaluated this hypothesis in a large-scale experimental system of open-habitat fragments that varied in shape and connectivity. Corridors increased nest predation rates in connected fragments relative to unconnected fragments with lower edge:area ratios. Nest predation rates were similar between connected and unconnected fragments with higher edge:area ratios. These results suggest that the increase in predator activity is largely attributable to edge effects incurred through the addition of a corridor. This is the first field study to demonstrate that corridors can negatively impact animal populations occupying connected fragments.

  6. The potential of electricity transmission corridors in forested areas as bumblebee habitat

    PubMed Central

    Hill, Bruce

    2016-01-01

    Declines in pollinator abundance and diversity are not only a conservation issue, but also a threat to crop pollination. Maintained infrastructure corridors, such as those containing electricity transmission lines, are potentially important wild pollinator habitat. However, there is a lack of evidence comparing the abundance and diversity of wild pollinators in transmission corridors with other important pollinator habitats. We compared the diversity of a key pollinator group, bumblebees (Bombus spp.), between transmission corridors and the surrounding semi-natural and managed habitat types at 10 sites across Sweden's Uppland region. Our results show that transmission corridors have no impact on bumblebee diversity in the surrounding area. However, transmission corridors and other maintained habitats such as roadsides have a level of bumblebee abundance and diversity comparable to semi-natural grasslands and host species that are important for conservation and ecosystem service provision. Under the current management regime, transmission corridors already provide valuable bumblebee habitat, but given that host plant density is the main determinant of bumblebee abundance, these areas could potentially be enhanced by establishing and maintaining key host plants. We show that in northern temperate regions the maintenance of transmission corridors has the potential to contribute to bumblebee conservation and the ecosystem services they provide. PMID:28018640

  7. The potential of electricity transmission corridors in forested areas as bumblebee habitat.

    PubMed

    Hill, Bruce; Bartomeus, Ignasi

    2016-11-01

    Declines in pollinator abundance and diversity are not only a conservation issue, but also a threat to crop pollination. Maintained infrastructure corridors, such as those containing electricity transmission lines, are potentially important wild pollinator habitat. However, there is a lack of evidence comparing the abundance and diversity of wild pollinators in transmission corridors with other important pollinator habitats. We compared the diversity of a key pollinator group, bumblebees (Bombus spp.), between transmission corridors and the surrounding semi-natural and managed habitat types at 10 sites across Sweden's Uppland region. Our results show that transmission corridors have no impact on bumblebee diversity in the surrounding area. However, transmission corridors and other maintained habitats such as roadsides have a level of bumblebee abundance and diversity comparable to semi-natural grasslands and host species that are important for conservation and ecosystem service provision. Under the current management regime, transmission corridors already provide valuable bumblebee habitat, but given that host plant density is the main determinant of bumblebee abundance, these areas could potentially be enhanced by establishing and maintaining key host plants. We show that in northern temperate regions the maintenance of transmission corridors has the potential to contribute to bumblebee conservation and the ecosystem services they provide.

  8. Design of T-Split Power Divider Using Double Ended Spur-Line DMS

    NASA Astrophysics Data System (ADS)

    Moyra, Tamasi; Parui, Susanta Kumar; Das, Santanu

    2016-09-01

    Power dividers and power combiners are passive microwave components for power dividing and power combining. In this article one T-split equal power divider has been designed by using conventional 50 Ω microstrip line and double ended spur line renamed as defected microstrip structures (DMS). Introducing DMS provides one stop band characteristics, changes the effective inductance and capacitance of the line by increasing effective dielectric constant, reduces the phase velocity and supports slow-wave propagation. Thus, increases the effective line impedance of the microstrip line. Consequently, all passive and active components that are implemented using DMS have a miniaturized size compared to conventional components. In this paper one 3 dB or equal power divider has been designed at 1.6 GHz in the first step. Where, 100 Ω output line is implemented using double ended spur type DMS on conventional 50 Ω microstrip line. In the second step each output port power has been divided equally into 6 dB in the next level of the branch. Design of those dividers are very simple and have wide applications in microwave circuits and feeds of array antennas.

  9. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1994-05-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this booklet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  10. 2. Pipe Floor Front Corridor, view to the northwest, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Pipe Floor Front Corridor, view to the northwest, with Unit 4 turbine pit visible in right foreground of photograph. One of the governor compressors, originally used as an air blast circuit breaker compressor, is visible in the left foreground with one of the station sump and unwatering pump clusters located just beyond the compressor. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  11. 2. Operating Floor Rear (west) Corridor, view to the south. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Operating Floor Rear (west) Corridor, view to the south. Note the cooling and service water take-off pipes for Unit 4 visible in left foreground of photograph. The deck plating that covers the oil pipes is also visible in the photograph. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  12. 78 FR 77550 - Integrated Corridor Management Deployment Planning Grants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ... Federal Highway Administration Integrated Corridor Management Deployment Planning Grants AGENCY: Federal... is extending the application period for the Integrated Corridor Management Deployment Planning Grants... Integrated Corridor Management Deployment Planning Grants. The purpose of this notice was to invite...

  13. An algorithm for power line detection and warning based on a millimeter-wave radar video.

    PubMed

    Ma, Qirong; Goshi, Darren S; Shih, Yi-Chi; Sun, Ming-Ting

    2011-12-01

    Power-line-strike accident is a major safety threat for low-flying aircrafts such as helicopters, thus an automatic warning system to power lines is highly desirable. In this paper we propose an algorithm for detecting power lines from radar videos from an active millimeter-wave sensor. Hough Transform is employed to detect candidate lines. The major challenge is that the radar videos are very noisy due to ground return. The noise points could fall on the same line which results in signal peaks after Hough Transform similar to the actual cable lines. To differentiate the cable lines from the noise lines, we train a Support Vector Machine to perform the classification. We exploit the Bragg pattern, which is due to the diffraction of electromagnetic wave on the periodic surface of power lines. We propose a set of features to represent the Bragg pattern for the classifier. We also propose a slice-processing algorithm which supports parallel processing, and improves the detection of cables in a cluttered background. Lastly, an adaptive algorithm is proposed to integrate the detection results from individual frames into a reliable video detection decision, in which temporal correlation of the cable pattern across frames is used to make the detection more robust. Extensive experiments with real-world data validated the effectiveness of our cable detection algorithm.

  14. Wildlife and electric power transmission

    USGS Publications Warehouse

    Ellis, D.H.; Goodwin, J.G.; Hunt, J.R.; Fletcher, John L.; Busnel, R.G.

    1978-01-01

    Hundreds of thousands of miles of transmission lines have been introduced into our natural environment. These lines and their corridors can be damaging or beneficial to wildlife communities depending on how they are designed, where they are placed, and when they are constructed and maintained. With the current trend toward UHV systems, new problems (associated with additional increments in audible noise, electric and magnetic force fields, etc.) must be addressed. We recommend the following areas for careful study: (1) the response of wilderness species to transmission lines and line construction and maintenance activities (2) the magnitude of bird collision and electrocution mortality, (3) the response of power corridor and power tower in habiting wildlife to laboratory and field doses of electro-chemical oxidants, corona noise, electric and magnetic fields, etc., (4) the productivity of tower inhabiting birds compared with nearby non-tower nesters, and (5) the influence of powerline corridors on mammalian and avian migration patterns. It is our hope that the questions identified in this study will help stimulate further research so that we can maximize wildlife benefits and minimize wildlife detriments.

  15. Lines of development of tower-type solar power plants

    NASA Astrophysics Data System (ADS)

    Henseler, H.-J.

    1981-10-01

    Problem areas in the development of tower-type solar power plants are discussed. The mode of functioning of such plants is briefly reviewed and the economic shortcomings of solar energy devices are summarized. Technical aspects and requirements of the system devices are summarized. Technical aspects and requirements of the system components are detailed, including the reflector, the receiver, the circuit, the tower, and the storage.

  16. Design of replica bit line control circuit to optimize power for SRAM

    NASA Astrophysics Data System (ADS)

    Pengjun, Wang; Keji, Zhou; Huihong, Zhang; Daohui, Gong

    2016-12-01

    A design of a replica bit line control circuit to optimize power for SRAM is proposed. The proposed design overcomes the limitations of the traditional replica bit line control circuit, which cannot shut off the word line in time. In the novel design, the delay of word line enable and disable paths are balanced. Thus, the word line can be opened and shut off in time. Moreover, the chip select signal is decomposed, which prevents feedback oscillations caused by the replica bit line and the replica word line. As a result, the switch power caused by unnecessary discharging of the bit line is reduced. A 2-kb SRAM is fully custom designed in an SMIC 65-nm CMOS process. The traditional replica bit line control circuit and the new replica bit line control circuit are used in the designed SRAM, and their performances are compared with each other. The experimental results show that at a supply voltage of 1.2 V, the switch power consumption of the memory array can be reduced by 53.7%. Project supported by the Zhejiang Provincial Natural Science Foundation of China (No. LQ14F040001), the National Natural Science Foundation of China (Nos. 61274132, 61234002, 61474068), and the K. C. Wong Magna Fund in Ningbo University.

  17. Rail transportation corridor analysis report: Deaf Smith County location in the Palo Duro Basin, Texas

    SciTech Connect

    Not Available

    1986-10-01

    An environmental data base was developed for the purpose of preliminary siting of potential rail access corridors between existing rail lines and the potential repository site in Deaf Smith County, Texas. The categories of the data base were environmental conditions considered significant in rail line construction and operation. These included land cover, population areas, slope, surface hydrology, cultivated prime agricultural lands, cultural features, and utility rights-of-way. The categories were divided into avoidance, constraint, and opportunity features, and the constraint features were then weighted for environmental impact potential. An environmental screening analysis using the computerized Geographical Information System (GIS) was then performed. The analysis involved applying the GIS overlay process to the various constraint data categories to produce a composite constraint map of the study area. The composite constraint map, color coded for various levels of constraint to corridor siting, was subsequently used as a guide for the selection of a series of alternative corridors. By means of a further application of GIS procedures, the corridor alternatives were statistically analyzed for adherence to corridor selection guidelines. In addition, a supplementary analysis was performed to compare the alternatives in terms of four impact categories: road crossings, construction costs, degree of land disruption, and population impact. The statistical and supplementary impact analyses led to a preliminary selection of a preferred corridor. The corridor assessment process indicated the importance of analyzing alternative trade-offs, as well as the need for more detailed investigation of certain conditions and a detailed comparison of alternatives prior to final corridor siting.

  18. Power-Line Harmonic Radiation: Can It Significantly Affect the Earth's Radiation Belts?

    PubMed

    Thorne, R M; Tsurutani, B T

    1979-05-25

    It has been suggested that harmonic radiation from the earth's 50- and 60-hertz power transmission lines might significantly influence the distribution of electrons in the radiation belts. On the basis of observations presented here, it seems advisable to accept such a hypothesis with caution. New evidence suggests that power-line radiation does not play any major role in the nonadiabatic dynamics of radiation belt electrons.

  19. Power-line harmonic radiation - Can it significantly affect the earth's radiation belts

    NASA Technical Reports Server (NTRS)

    Thorne, R. M.; Tsurutani, B. T.

    1979-01-01

    It has been suggested that harmonic radiation from the earth's 50- and 60-hertz power transmission lines might significantly influence the distribution of electrons in the radiation belts. On the basis of observations presented here, it seems advisable to accept such a hypothesis with caution. New evidence suggests that power-line radiation does not play any major role in the nonadiabatic dynamics of radiation belt electrons.

  20. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1993-11-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this pamphlet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. (BPA is the Pacific Northwest`s Federal electric power marketing agency.) First, some basic electrical terms are defined, and electric and magnetic fields are described. Next, answers are given to several questions about recent scientific studies. We then describe how BPA is addressing public concerns raised by these studies. Some important information about electrical safety follows. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this pamphlet.

  1. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  2. Avian behavior and mortality at power lines in coastal South Carolina

    USGS Publications Warehouse

    Savereno, A.J.; Savereno, L.A.; Boettcher, R.; Haig, S.M.

    1996-01-01

    We compared avian behavior and mortality associated with two 115-kV transmission lines on the central South Carolina coast during 3,392 hours of observation from May 1991 through May 1994. One line was marked with 30-cm-diameter yellow aviation markers. The second line was unmarked, but was similar in most other aspects. We conducted ground searches (n = 445) beneath each line year-round to document avian mortality due to power-line collisions. At marked lines, birds that approached at line height changed behavior more at unmarked lines (P< 0.001), and fewer crossed between static and conductor wires. Collision rate was 53% lower at marked than unmarked lines. Among collisions at both sites, 82% of birds collided with static wires. Based on observed collisions and carcass recoveries, wading birds particularly appeared to be at risk. We concluded that aviation markers were effective at increasing line visibility and reducing collisions and recommend marking static wires of power lines in potentially sensitive areas.

  3. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all voltages... an energized power line is prohibited, except where the employer demonstrates that all of...

  4. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  5. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  6. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety (all voltages)-equipment operations... FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1410 Power line safety (all...

  7. Circuit and Method for Communication Over DC Power Line

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Norman F.

    2007-01-01

    A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal

  8. Modification of atmospheric DC fields by space charge from high-voltage power lines

    NASA Astrophysics Data System (ADS)

    Fews, A. P.; Wilding, R. J.; Keitch, P. A.; Holden, N. K.; Henshaw, D. L.

    Corona ion discharge is responsible for a flux of small ions emanating from an overhead power line capable of modifying the ambient electrical environment. The ensuing space charge can be detected as a change in magnitude of the earth's natural DC electric field at ground level. DC field mill meters were used to measure the vertical component of electric fields upwind and downwind of 132 and 400 kV power lines. Evidence of space charge blowing downwind of power lines was observed in 21 out of 22 cases. Time series measurements recorded in the downwind direction were highly variable with fields of higher magnitude compared to those recorded upwind. Model DC field profiles were used to estimate a lower limit to the space charge density at body height arising from power lines. The average lower limit was ˜3000 cm -3 excess unipolar charges. The result suggests that between 10% and 60% of outdoor aerosols gain excess charge by the attachment of corona ions. Downwind of a 400 kV line in Somerset that was prone to excessive corona discharge, the estimated mean lower limit excess unipolar space charge density was ˜6000 cm -3, suggesting that up to 100% of aerosols gain excess charge by the attachment of corona ions. Investigations into the time variation of DC electric fields around motorways and the natural diurnal variation of the earth's DC field were also undertaken and compared to the power line data. The results show that the power line time series are clearly distinguishable from typical examples of both types of field variation, demonstrating the relatively highly charged atmospheres that generally exist around high-voltage power lines. The results are of potential public health concern, because they suggest a degree of aerosol charging that may result in a non-trivial increase in lung deposition of inhaled pollutant aerosols.

  9. Noise control in the transportation corridor.

    PubMed

    Manning, C J; Harris, G J

    2003-01-01

    This paper considers the opportunities for noise control within the route corridor required for construction of road, rail and other guided transport schemes. It deals with control of noise generation at source, and in the transmission path close to the point of generation. In this way it is possible to control the amount of acoustic power generated, and to absorb part of the radiated power at points of reflection. Purely reflective wayside barriers do little to absorb acoustic energy, merely reflecting it in a different direction. Whilst this has selfish benefits to the receptor in the shadow zone of the barrier, it makes things worse for others on the reflective side of the geometry. The paper therefore considers the options available to the engineer in the design of rolling and sliding interfaces and the use of acoustically absorptive finishes on all surfaces close to the point of noise generation. This includes the running surface itself, structural components, retaining walls, over and under passes, and the inner surfaces of track and wayside barriers.

  10. Effects of conductor sag on spatial distribution of power line magnetic field

    SciTech Connect

    Mamishev, A.V.; Nevels, R.D.; Russell, B.D.

    1996-07-01

    Traditional extremely low frequency (ELF) magnetic field computation techniques assume that the current carrying power line conductors are straight horizontal wires. This assumption results in a model whose magnetic fields are distorted from those produced in reality. An exact solution and an approximation are proposed for modeling magnetic fields produced by the sagged conductors of power lines, by taking advantage of the fact that the equation of the catenary exactly describes the line sag. The proposed approaches differ in the required computational burden and in the precision of the results. A field mapping measurement example illustrates the applicability and the need for this analysis. The relative importance of the catenary effect is discussed.

  11. Widom line and noise-power spectral analysis of a supercritical fluid.

    PubMed

    Han, Sungho; Yu, Clare C

    2012-05-01

    We have performed extensive molecular dynamics simulations to study noise-power spectra of density and potential energy fluctuations of a Lennard-Jones model of a fluid in the supercritical region. Emanating from the liquid-vapor critical point, there is a locus of isobaric specific heat maxima, called the Widom line, which is often regarded as an extension of the liquid-vapor coexistence line. Our simulation results show that the noise-power spectrum of the density fluctuations on the Widom line of the liquid-vapor transition exhibits three distinct 1/f^{γ} behaviors with exponents γ=0, 1.2, and 2, depending on the frequency f. We find that the intermediate frequency region with an exponent γ∼ 1 appears as the temperature approaches the Widom temperature from above or below. On the other hand, we do not find three distinct regions of 1/f^{γ} in the power spectrum of the potential energy fluctuations on the Widom line. Furthermore, we find that the power spectra of both the density and potential energy fluctuations at low frequency have a maximum on the Widom line, suggesting that the noise power can provide an alternative signature of the Widom line.

  12. A study of electric power transmission lines for use on the lunar surface

    NASA Technical Reports Server (NTRS)

    Gordon, Lloyd B.; Gaustad, Krista L.

    1991-01-01

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

  13. Do power lines and protected areas present a catch-22 situation for Cape vultures (Gyps coprotheres)?

    PubMed

    Phipps, W Louis; Wolter, Kerri; Michael, Michael D; MacTavish, Lynne M; Yarnell, Richard W

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area = 121,655±90,845 km(2)) and four immature (mean ±SD minimum convex polygon area = 492,300±259,427 km(2)) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa.

  14. Do Power Lines and Protected Areas Present a Catch-22 Situation for Cape Vultures (Gyps coprotheres)?

    PubMed Central

    Phipps, W. Louis; Wolter, Kerri; Michael, Michael D.; MacTavish, Lynne M.; Yarnell, Richard W.

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area  =  121,655±90,845 km2) and four immature (mean ±SD minimum convex polygon area  =  492,300±259,427 km2) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa. PMID:24137496

  15. Power lines, roads, and avian nest survival: effects on predator identity and predation intensity.

    PubMed

    DeGregorio, Brett A; Weatherhead, Patrick J; Sperry, Jinelle H

    2014-05-01

    1 Anthropogenic alteration of landscapes can affect avian nest success by influencing the abundance, distribution, and behavior of predators. Understanding avian nest predation risk necessitates understanding how landscapes affect predator distribution and behavior. 2 From a sample of 463 nests of 17 songbird species, we evaluated how landscape features (distance to forest edge, unpaved roads, and power lines) influenced daily nest survival. We also used video cameras to identify nest predators at 137 nest predation events and evaluated how landscape features influenced predator identity. Finally, we determined the abundance and distribution of several of the principal predators using surveys and radiotelemetry. 3 Distance to power lines was the best predictor of predator identity: predation by brown-headed cowbirds (Molothrus ater), corvids (Corvus sp. and Cyanocitta cristata), racers (Coluber constrictor), and coachwhips (Masticophis flagellum) increased with proximity to power lines, whereas predation by rat snakes (Elaphe obsoleta) and raptors decreased. In some cases, predator density may reliably indicate nest predation risk because racers, corvids, and cowbirds frequently used power line right-of-ways. 4 Of five bird species with enough nests to analyze individually, daily nest survival of only indigo buntings (Passerina cyanea) decreased with proximity to power lines, despite predation by most predators at our site being positively associated with power lines. For all nesting species combined, distance to unpaved road was the model that most influenced daily nest survival. This pattern is likely a consequence of rat snakes, the locally dominant nest predator (28% of predation events), rarely using power lines and associated areas. Instead, rat snakes were frequently associated with road edges, indicating that not all edges are functionally similar. 5 Our results suggest that interactions between predators and landscape features are likely to be specific to

  16. Bird behavior and mortality in relation to power lines in prairie habitats

    USGS Publications Warehouse

    Faanes, C.A.

    1987-01-01

    Research was conducted to determine the magnitude of avian mortality caused by power transmission lines in prairie habitats during the two spring and two fall migration periods between July 1980 and May 1982. Searches for dead birds were made at least twice weekly during each migration period. Study sites were selected to include 'worst-case' situations involving potentially large concentrations of birds.In total, 633 dead birds were found beneath 9.6 km of power lines. About 81% of the birds were found during fall migration. Removal of birds by scavengers was of minor, although local, importance, and observer error in finding birds was greatest in areas of dense vegetation. Total kill was estimated at 1,332 birds.Data were gathered on more than 7,000 bird flights observed in the vicinity of the power lines. Sixty-eight percent of the birds did not respond to the presence of the power lines. Flaring and climbing over the conductor or overhead ground wire occurred in about 25% of the flights. One hundred nine birds in 82 flocks were observed to collide with a power line. Of these birds, 87% flared to climb over the power line before colliding. The overhead ground wire was responsible for most deaths, as 102 of 109 birds collided with it.Whereas none of the mortality observed was considered to be biologically significant at the particular sites examined, the cumulative effect of mortality sustained from collisions with power lines may be important, particularly to populations of rare or endangered birds.

  17. 1. Pipe Floor Rear Corridor, view to the southeast. The ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Pipe Floor Rear Corridor, view to the southeast. The wall of Unit 2 turbine pit is visible in the right foreground. The pipe and valve cluster in the right foreground is part of the blow down valve for Unit 2. This valve allows the water in the draft chest to be lowered (i.e., 'blown down') so that the unit can be motored (i.e., run like an electric motor rather than an electric power generator). - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  18. Measurements and Modeling of Noise on 22.9-kV Medium-Voltage Underground Power Line for Broadband Power Line Communication

    NASA Astrophysics Data System (ADS)

    Lee, Seungjoon; Shin, Donghwan; Kim, Yonghwa; Lee, Jaejo; Eom, Kihwan

    This paper proposed the measurements and modeling of noise on the 22.9-kV Medium-Voltage (MV) underground power distribution cable for Broadband Power Line Communication (BPLC). The proposed measurement system was composed of inductive coupler and Digital Phosphor Oscilloscope (DPO). The measurement noise data was obtained from thirty-two pad mounted transformers in the test field located in Choji area of Ansan city. After conducting analysis of noise characteristics in time and frequency domain, the noise model are presented. In order to analyze the noise in frequency domain, Power Spectral Density (PSD) was computed with empirical data using Welch's method. The modeling of the power line noise at each frequency carried out using Cumulative Probability Distribution (CPD) of the noise power. It compared with common Cumulative Distribution Functions (CDF) of Nakagami-m distribution, Gaussian distribution, Gamma distribution. In low frequency range, gamma distribution was fitted with the CPD. Nakagami-m distribution provides a good fitting to the noise CPD above 20MHz frequency range.

  19. Predictive model of avian electrocution risk on overhead power lines.

    PubMed

    Dwyer, J F; Harness, R E; Donohue, K

    2014-02-01

    Electrocution on overhead power structures negatively affects avian populations in diverse ecosystems worldwide, contributes to the endangerment of raptor populations in Europe and Africa, and is a major driver of legal action against electric utilities in North America. We investigated factors associated with avian electrocutions so poles that are likely to electrocute a bird can be identified and retrofitted prior to causing avian mortality. We used historical data from southern California to identify patterns of avian electrocution by voltage, month, and year to identify species most often killed by electrocution in our study area and to develop a predictive model that compared poles where an avian electrocution was known to have occurred (electrocution poles) with poles where no known electrocution occurred (comparison poles). We chose variables that could be quantified by personnel with little training in ornithology or electric systems. Electrocutions were more common at distribution voltages (≤ 33 kV) and during breeding seasons and were more commonly reported after a retrofitting program began. Red-tailed Hawks (Buteo jamaicensis) (n = 265) and American Crows (Corvus brachyrhynchos) (n = 258) were the most commonly electrocuted species. In the predictive model, 4 of 14 candidate variables were required to distinguish electrocution poles from comparison poles: number of jumpers (short wires connecting energized equipment), number of primary conductors, presence of grounding, and presence of unforested unpaved areas as the dominant nearby land cover. When tested against a sample of poles not used to build the model, our model distributed poles relatively normally across electrocution-risk values and identified the average risk as higher for electrocution poles relative to comparison poles. Our model can be used to reduce avian electrocutions through proactive identification and targeting of high-risk poles for retrofitting.

  20. Corridor Length and Patch Colonization by a Butterfly Junonia coenia

    SciTech Connect

    Nick Haddad

    2000-06-01

    Habitat corridors have been proposed to reduce patch isolation and increase population persistence in fragmented landscapes. This study tested whether patch colonization was increased by the presence and various length corridors. The specific butterfly species tested has been shown to use corridors, however, the results indicate that neither the distance between patches or the presence of a corridor influenced colonization.

  1. A novel high-power dual-band coupled-line Gysel power divider with impedance-transforming functions.

    PubMed

    Wang, Weimin; Wu, Yongle; Liu, Yuanan

    2014-01-01

    A novel coupled-line structure is proposed to design dual-band and high-power Gysel power dividers with inherent impedance-transforming functions. Based on traditional even- and odd-mode technique, the analytical design methods in closed-form formula are obtained and the accurate electrical parameters analysis is presented. Due to the usage of coupled-line sections, more design-parameter freedom and a wider frequency-ratio operation range for this kind of dual-band Gysel powder divider are obtained. Several numerical examples are designed and calculated to demonstrate flexible dual-band applications with different impedance-transforming functions. A practical microstrip power divider operating at 2 GHz and 3.2 GHz is designed, fabricated, and measured. The good agreement between the calculated and measured results verifies our proposed circuit structure and analytical design approach.

  2. A Novel High-Power Dual-Band Coupled-Line Gysel Power Divider with Impedance-Transforming Functions

    PubMed Central

    Wang, Weimin; Liu, Yuanan

    2014-01-01

    A novel coupled-line structure is proposed to design dual-band and high-power Gysel power dividers with inherent impedance-transforming functions. Based on traditional even- and odd-mode technique, the analytical design methods in closed-form formula are obtained and the accurate electrical parameters analysis is presented. Due to the usage of coupled-line sections, more design-parameter freedom and a wider frequency-ratio operation range for this kind of dual-band Gysel powder divider are obtained. Several numerical examples are designed and calculated to demonstrate flexible dual-band applications with different impedance-transforming functions. A practical microstrip power divider operating at 2 GHz and 3.2 GHz is designed, fabricated, and measured. The good agreement between the calculated and measured results verifies our proposed circuit structure and analytical design approach. PMID:24764768

  3. Measurements of the Ech Power and of the Transmission Line Losses on Diii-D

    NASA Astrophysics Data System (ADS)

    Cengher, M.; Lohr, J.; Gorelov, I. A.; Grosnickle, W. H.; Ponce, D.; Johnson, P.

    2009-04-01

    The measurement of the power injected by the electron cyclotron heating (ECH) system in the DIII-D tokamak is a critical requirement for analysis of experiments, for tuning the gyrotrons for maximum power and efficiency, for tracking long-term operational trends and for providing a warning of problems with the system. The ECH system at General Atomics consists of six 110 GHz, 1 MW class gyrotrons. The rf power generated by each gyrotron is determined from calorimetry, using the relevant temperature and flow measurements from the cooling circuits of cavity, matching optics unit and dummy loads. The rf pulse length and time dependence are measured using an rf monitor at the first miter bend in the transmission line. The direct measurement of the efficiencies of four of the transmission lines was performed using a high power, small dummy load (SDL) placed alternately in 2 positions of each DIII-D waveguide line, at accessible points close the beginning and the end of each line. Total losses in the transmission lines range from 21.2% to 30.7%. Experimental results are compared to theoretical predictions of the performance of the components and waveguide lines.

  4. Childhood cancer and exposure to corona ions from power lines: an epidemiological test.

    PubMed

    Swanson, J; Bunch, K J; Vincent, T J; Murphy, M F G

    2014-12-01

    We previously reported an association between childhood leukaemia in Britain and proximity of the child's address at birth to high-voltage power lines that declines from the 1960s to the 2000s. We test here whether a 'corona-ion hypothesis' could explain these results. This hypothesis proposes that corona ions, atmospheric ions produced by power lines and blown away from them by the wind, increase the retention of airborne pollutants in the airways when breathed in and hence cause disease. We develop an improved model for calculating exposure to corona ions, using data on winds from meteorological stations and considering the whole length of power line within 600 m of each subject's address. Corona-ion exposure is highly correlated with proximity to power lines, and hence the results parallel the elevations in leukaemia risk seen with distance analyses. But our model explains the observed pattern of leukaemia rates around power lines less well than straightforward distance measurements, and ecological considerations also argue against the hypothesis. This does not disprove the corona-ion hypothesis as the explanation for our previous results, but nor does it provide support for it, or, by extension, any other hypothesis dependent on wind direction.

  5. Research of on-line monitoring method for insulation condition of power transformer bushing

    NASA Astrophysics Data System (ADS)

    Xia, Jiuyun; Qian, Zheng; Yu, Hao; Yao, Junda

    2016-01-01

    The power transformer is the key equipment of the power system; its insulation condition will directly influence the security and reliability of the power system. Thus, the on-line monitoring of power transformer is urgently required in order to guarantee the normal operation of the power system. Moreover, the dielectric loss factor is a significant parameter reflecting the condition of transformer bushing, so the on-line measurement of dielectric loss factor is really important. In this paper, the phase-to-phase comparison method is selected as the on-line monitoring method based on the overall analysis and discussion of the existing on-line monitoring methods. At first, the harmonic analysis method is utilized to calculate the dielectric loss of each phase of the three-phase transformer bushing, and then the differences of dielectric loss between every two phases are calculated and analyzed. So the insulation condition of each bushing could be achieved based on the careful analysis of different phase-to-phase dielectric loss. The simulation results of phase-to-phase comparison method are carried out in this paper, and the validity is verified. At last, this method is utilized in an actual equipment of on-line monitoring.

  6. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    NASA Astrophysics Data System (ADS)

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  7. A bee in the corridor: centering and wall-following

    NASA Astrophysics Data System (ADS)

    Serres, Julien R.; Masson, Guillaume P.; Ruffier, Franck; Franceschini, Nicolas

    2008-12-01

    In an attempt to better understand the mechanism underlying lateral collision avoidance in flying insects, we trained honeybees ( Apis mellifera) to fly through a large (95-cm wide) flight tunnel. We found that, depending on the entrance and feeder positions, honeybees would either center along the corridor midline or fly along one wall. Bees kept following one wall even when a major (150-cm long) part of the opposite wall was removed. These findings cannot be accounted for by the “optic flow balance” hypothesis that has been put forward to explain the typical bees’ “centering response” observed in narrower corridors. Both centering and wall-following behaviors are well accounted for, however, by a control scheme called the lateral optic flow regulator, i.e., a feedback system that strives to maintain the unilateral optic flow constant. The power of this control scheme is that it would allow the bee to guide itself visually in a corridor without having to measure its speed or distance from the walls.

  8. Transmission line design for a power distribution system at 20 kHz for aircraft

    NASA Technical Reports Server (NTRS)

    Zelby, L. W.; Mathes, J. B.; Shawver, J. W.

    1986-01-01

    A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

  9. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1995-06-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the EMF (electric and magnetic fields) produced by power lines and other electrical devices affect our health. Although no adverse health effects of electric power EMF have been confirmed, there is continued scientific uncertainty about this issue. Research on EMF is ongoing throughout the world. The purpose of this booklet is to answer some common questions that the BPA (Bonneville Power Administration) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  10. REDD+ Policy: Corridors of carbon and biodiversity

    NASA Astrophysics Data System (ADS)

    Venter, Oscar

    2014-02-01

    Reducing tropical deforestation has huge potential for mitigating climate change and saving the Earth's most biologically diverse biome. Corridors connecting existing protected areas represent an elegant means of attaining both goals.

  11. Nonlinear femtosecond pump-probe spectroscopy using a power-encoded soliton delay line.

    PubMed

    Saint-Jalm, Sarah; Andresen, Esben Ravn; Bendahmane, Abdelkrim; Kudlinski, Alexandre; Rigneault, Hervé

    2016-01-01

    We show femtosecond time-resolved nonlinear pump-probe spectroscopy using a fiber soliton as the probe pulse. Furthermore, we exploit soliton dynamics to record an entire transient trace with a power-encoded delay sweep. The power-encoded delay line takes advantage of the dependency of the soliton trajectory in the (λ,z) space upon input power; the difference in accumulated group delay between trajectories converts a fast power sweep into a fast delay sweep. We demonstrate the concept by performing transient absorption spectroscopy in a test sample and validate it against a conventional pump-probe setup.

  12. Corridor Length and Patch Colonization by a Butterfly, Junonia coenia

    SciTech Connect

    Haddad, N.

    1999-01-22

    Study hypothesized that corridors increase patch colonization by Junonia coenia regardless of insects initial distance from patch, as the butterfly is known to move between patches preferentially through corridors. Neither corridor nor distance had significant effect on patch colonization, but significant interaction between presence or absence of corridors and distance. One critical factor is interpatch distance which may determine the relative effectiveness of corridors and other landscape configurations.

  13. 85Rb D1-Line Coherent-Population-Trapping Atomic Clock for Low-Power Operation

    NASA Astrophysics Data System (ADS)

    Goka, Shigeyoshi

    2010-06-01

    A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.

  14. 85Rb D1-Line Coherent-Population-Trapping Atomic Clock for Low-Power Operation

    NASA Astrophysics Data System (ADS)

    Shigeyoshi Goka,

    2010-06-01

    A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5× 10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.

  15. Visual based navigation for power line inspection by using virtual environments

    NASA Astrophysics Data System (ADS)

    Cerón, Alexander; Mondragón, Iván. F.; Prieto, Flavio

    2015-01-01

    Power line inspection is an important task for the maintenance of electrical infrastructure. UAVs (Unmanned aerial vehicle) can be very useful in the inspection process because the high costs of obtaining images of power lines from different perspectives and the logistic problems of manned flights. The use of the power line as a reference for navigation can be difficult because the different backgrounds, we consider the use of the tower as a reference in order to improve the orientation of the UAV respect to the electrical grid. In this work we generate a process for navigation based in tower detection. The navigation is performed by using the information extracted from a frontal camera in a visual control scheme and validated in virtual environments.

  16. A system for tranmitting low frequency analog signals over ac power lines

    DOEpatents

    Baker, S.P.; Durall, R.L.; Haynes, H.D.

    1987-07-30

    A system for transmitting low frequency analog signals over ac power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an ac power line. The modulation signal frequency range is selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the ac power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal. 4 figs.

  17. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-01-01

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  18. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-09-05

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  19. Refining Estimates of Bird Collision and Electrocution Mortality at Power Lines in the United States

    PubMed Central

    Loss, Scott R.; Will, Tom; Marra, Peter P.

    2014-01-01

    Collisions and electrocutions at power lines are thought to kill large numbers of birds in the United States annually. However, existing estimates of mortality are either speculative (for electrocution) or based on extrapolation of results from one study to all U.S. power lines (for collision). Because national-scale estimates of mortality and comparisons among threats are likely to be used for prioritizing policy and management strategies and for identifying major research needs, these estimates should be based on systematic and transparent assessment of rigorously collected data. We conducted a quantitative review that incorporated data from 14 studies meeting our inclusion criteria to estimate that between 12 and 64 million birds are killed each year at U.S. power lines, with between 8 and 57 million birds killed by collision and between 0.9 and 11.6 million birds killed by electrocution. Sensitivity analyses indicate that the majority of uncertainty in our estimates arises from variation in mortality rates across studies; this variation is due in part to the small sample of rigorously conducted studies that can be used to estimate mortality. Little information is available to quantify species-specific vulnerability to mortality at power lines; the available literature over-represents particular bird groups and habitats, and most studies only sample and present data for one or a few species. Furthermore, additional research is needed to clarify whether, to what degree, and in what regions populations of different bird species are affected by power line-related mortality. Nonetheless, our data-driven analysis suggests that the amount of bird mortality at U.S. power lines is substantial and that conservation management and policy is necessary to reduce this mortality. PMID:24991997

  20. Refining estimates of bird collision and electrocution mortality at power lines in the United States.

    PubMed

    Loss, Scott R; Will, Tom; Marra, Peter P

    2014-01-01

    Collisions and electrocutions at power lines are thought to kill large numbers of birds in the United States annually. However, existing estimates of mortality are either speculative (for electrocution) or based on extrapolation of results from one study to all U.S. power lines (for collision). Because national-scale estimates of mortality and comparisons among threats are likely to be used for prioritizing policy and management strategies and for identifying major research needs, these estimates should be based on systematic and transparent assessment of rigorously collected data. We conducted a quantitative review that incorporated data from 14 studies meeting our inclusion criteria to estimate that between 12 and 64 million birds are killed each year at U.S. power lines, with between 8 and 57 million birds killed by collision and between 0.9 and 11.6 million birds killed by electrocution. Sensitivity analyses indicate that the majority of uncertainty in our estimates arises from variation in mortality rates across studies; this variation is due in part to the small sample of rigorously conducted studies that can be used to estimate mortality. Little information is available to quantify species-specific vulnerability to mortality at power lines; the available literature over-represents particular bird groups and habitats, and most studies only sample and present data for one or a few species. Furthermore, additional research is needed to clarify whether, to what degree, and in what regions populations of different bird species are affected by power line-related mortality. Nonetheless, our data-driven analysis suggests that the amount of bird mortality at U.S. power lines is substantial and that conservation management and policy is necessary to reduce this mortality.

  1. Numerical simulation of overvoltage caused by lightning on aerial power lines, including the corona effect

    NASA Astrophysics Data System (ADS)

    Ahcene, Z.; Bernard, G.

    1981-12-01

    A corona effect analog model is studied, and the influence of surges due to lightning on power lines is discussed. The effect of a lightning strike on lines with and without guard cables was simulated. Results show that the surge is very strongly damped as it travels away from the strike point. The corona effect lengthens front times and dampens the high frequency components of the propagated waves.

  2. Long integral temperature Brillouin sensor for off- shore wind energy power supply lines

    NASA Astrophysics Data System (ADS)

    Quintela, M. A.; Ullán, A.; Quintela, A.; Galindez, C.; Perez-Herrera, R. A.; López-Amo, M.; Lopez-Higuera, J. M.

    2011-05-01

    A hybrid Erbium-Brillouin fiber laser sensor to measure the temperature along 22 km fiber is proposed and experimentally demonstrated. A multi-line laser oscillation is induced by the Brillouin gain of different concatenated transducer fiber sections placed in the ring cavity. Integral temperature measurements of each fiber section are obtained through each laser line. This sensor can be used to monitor the temperature of off-shore wind energy power cables.

  3. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... so that it is in view of the operator and (except for overhead gantry and tower cranes) at least two... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or...

  4. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... so that it is in view of the operator and (except for overhead gantry and tower cranes) at least two... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or...

  5. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... so that it is in view of the operator and (except for overhead gantry and tower cranes) at least two... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or...

  6. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... so that it is in view of the operator and (except for overhead gantry and tower cranes) at least two... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and disassembly...) Assembly/disassembly below power lines prohibited. No part of a crane/derrick, load line, or...

  7. On the application of a machine learning technique to fault diagnosis of power distribution lines

    SciTech Connect

    Togami, Masato; Abe, Norihiro; Kitahashi, T.; Ogawa, Harunao

    1995-10-01

    This paper presents one method for fault diagnosis of power distribution lines by using a decision tree. The conventional method, using a decision tree, applies only to discrete attribute values. To apply it to fault diagnosis of power distribution lines, in practice it must be revised in order to treat attributes whose values range over certain widths. This is because the sensor value or attribute value varies owing to the resistance of the fault point or is influenced by noise. The proposed method is useful when the attribute value has such a property, and it takes into consideration the cost of acquiring the information and the probability of the occurrence of a fault.

  8. Comparison of charged nanoparticle concentrations near busy roads and overhead high-voltage power lines.

    PubMed

    Jayaratne, E R; Ling, X; Morawska, L

    2015-09-01

    Overhead high-voltage power lines are known sources of corona ions. These ions rapidly attach to aerosols to form charged particles in the environment. Although the effect of ions and charged particles on human health is largely unknown, much attention has focused on the increasing exposure as a result of the expanding power network in urban residential areas. However, it is not widely known that a large number of charged particles in urban environments originate from motor vehicle emissions. In this study, for the first time, we compare the concentrations of charged nanoparticles near busy roads and overhead power lines. We show that large concentrations of both positive and negative charged nanoparticles are present near busy roadways and that these concentrations commonly exceed those under high-voltage power lines. We estimate that the concentration of charged nanoparticles found near two freeways carrying around 120 vehicles per minute exceeded the corresponding maximum concentrations under two corona-emitting overhead power lines by as much as a factor of 5. The difference was most pronounced when a significant fraction of traffic consisted of heavy-duty diesel vehicles which typically have high particle and charge emission rates.

  9. Observations of radiation from power lines in near-earth space

    NASA Astrophysics Data System (ADS)

    Korepanov, V. E.; Dudkin, F. L.; Pronenko, V. A.

    2015-09-01

    The possible effects of technogenic impacts on the ionosphere, with the continuing trend towards its sustainable growth, are unknown today. It is therefore very important and urgent task to conduct statistically valid research related to the study of variations of ionospheric parameters due to the influence of powerful technogenic factors, primarily due to a significant increase of the electromagnetic energy production. In this paper, we discuss new results of observations of electromagnetic fields in the ionosphere at the power lines main frequency of 50 (60) Hz and its harmonics onboard SICH-1M (2004) and CHIBIS-M (2012-2014) satellites. The spatial distribution of the observed phenomena and their connection with possible ground-based sources-powerful transmission lines is presented. It is concluded that organization of regular monitoring of technogenic fields may allow continuous control of energy consumption in both the local (within a country or even a powerful consumer) and global scales.

  10. Magnet power supply control of the NSLS VUV and x-ray storage rings transfer lines

    SciTech Connect

    Klein, J.D.; Ramamoorthy, S.; Singh, O.; Smith, J.D.

    1985-01-01

    The transfer lines for NSLS VUV and x-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed.

  11. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    SciTech Connect

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander; Dennerlein, Juergen; Janke, Iryna; Weber, Johannes

    2015-07-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a

  12. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    PubMed

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  13. High precision ultrasonic guided wave technique for inspection of power transmission line

    NASA Astrophysics Data System (ADS)

    Cheng, Jun; Qiu, Jinhao; Ji, Hongli; Wang, Enrong; Takagi, Toshiyuki; Uchimoto, Tetsuya

    2017-01-01

    Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.

  14. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    PubMed Central

    Wang, Wenming

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  15. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines.

    PubMed

    Reale, D V; Bragg, J-W B; Gonsalves, N R; Johnson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2014-05-01

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  16. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

    SciTech Connect

    Reale, D. V. Bragg, J.-W. B.; Gonsalves, N. R.; Johnson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2014-05-15

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  17. HHFW Power Flow Along Magnetic Field Lines In The Scrape-off Layer of NSTX

    SciTech Connect

    Rory Perkins, et. al.

    2012-02-27

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast wave heating and current drive.

  18. In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

    SciTech Connect

    Mueller, Steffen; Weigel, Robert; Koelpin, Alexander; Dennerlein, Juergen; Janke, Iryna; Weber, Johannes

    2015-07-01

    Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

  19. Direct and nearby lightning strike interaction with test power distribution lines

    NASA Astrophysics Data System (ADS)

    Schoene, Jens Daniel

    The interaction of direct and nearby rocket-triggered lightning with two unenergized three-phase power distribution lines of about 800 m length was studied at the International Center for Lightning Research and Testing in Florida. A horizontally-configured line was tested in 1999 and 2000, a vertically-configured line in 2001, 2002, and 2003, and a vertically-configured line with overhead ground wire in 2004. All lines were equipped with arresters and, additionally, in 2003, the vertical line had a polemounted transformer. During the 2000, 2001, and 2002 direct strike experiments, arresters frequently failed, but there was no arrester failures either during the 2003 direct strike experiment when the transformer was on the line or during the 2004 direct strike experiment when the lightning current was injected into the overhead ground wire. All line configurations except the one tested in 2004 commonly exhibited flashovers. The division of return stroke currents for the vertically-configured line was initially similar to the division on the horizontally-configured line (that is, the arresters closest to the strike point conducted the bulk of the impulsive current). After some tens of microseconds the currents in all arresters on the vertically-configured line equalized, while the close arrester currents on the horizontally-configured line still conducted significantly more current than the remote arresters. The lightning current division for direct strikes to a phase conductor is successfully modeled with the Electromagnetic Transient Program (EMTP) for the vertically-configured line and, if the residual voltage of the close arresters is reduced by 20%, successfully modeled for the horizontally-configured line. Currents on the vertically-configured line induced by nearby lightning strikes were measured and compared to results calculated using the LIOV-EMTP96 code. It was found that during a lightning strike 11 m from a grounded line pole, a significant fraction of

  20. Evaluation of line focus solar central power systems. Volume II. Systems evaluation

    SciTech Connect

    Not Available

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

  1. NEW APPROACHES: Magnetic and electric field strengths of high voltage power lines and household appliances

    NASA Astrophysics Data System (ADS)

    Austin, Lydia

    1997-03-01

    A readily obtainable meter can be used to measure the magnetic and electric field strengths of high voltage power lines and household appliances. Simple calculations show that all likely exposures are below, mostly well below, the maximum exposures recommended by the World Health Organisation.

  2. Power Line Technician. Second Edition. Module C. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This module is the third in a series that is designed to help students achieve greater professional and personal success as power line technicians. Each module represents one or more complete units of instruction with components organized into one instructor and one student "package": the instructor's manual and the student workbook. The…

  3. Power Line Technician. Second Edition. Module D. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This module is the fourth in a series that is designed to help students achieve greater professional and personal success as power line technicians. Each module represents one or more complete units of instruction with components organized into one instructor and one student "package": the instructor's manual and the student workbook.…

  4. Wired: impacts of increasing power line use by a growing bird population

    NASA Astrophysics Data System (ADS)

    Moreira, Francisco; Encarnação, Vitor; Rosa, Gonçalo; Gilbert, Nathalie; Infante, Samuel; Costa, Julieta; D’Amico, Marcello; Martins, Ricardo C.; Catry, Inês

    2017-02-01

    Power lines are increasingly widespread across many regions of the planet. Although these linear infrastructures are known for their negative impacts on bird populations, through collision and electrocution, some species take advantage of electricity pylons for nesting. In this case, estimation of the net impact of these infrastructures at the population level requires an assessment of trade-offs between positive and negative impacts. We compiled historical information (1958–2014) of the Portuguese white stork Ciconia ciconia population to analyze long-term changes in numbers, distribution range and use of nesting structures. White stork population size increased 660% up to 12000 breeding pairs between 1984 and 2014. In the same period, the proportion of nests on electricity pylons increased from 1% to 25%, likely facilitated by the 60% increase in the length of the very high tension power line grid (holding the majority of the nests) in the stork’s distribution range. No differences in breeding success were registered for storks nesting on electricity pylons versus other structures, but a high risk of mortality by collision and electrocution with power lines was estimated. We discuss the implications of this behavioral change, and of the management responses by power line companies, both for stork populations and for managers.

  5. Power Line Technician. Second Edition. Module B. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This module is the second in a series that is designed to help students achieve greater professional and personal success as power line technicians. Each module represents one or more complete units of instruction with components organized into one instructor and one student "package": the instructor's manual and the student workbook.…

  6. 76 FR 76044 - Safety Zone; Power Line Replacement, West Bay, Panama City, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Power Line Replacement, West Bay, Panama... prohibited to all vessels and persons unless specifically authorized by the Captain of the Port (COTP) Mobile.... Coast Guard Sector Mobile (spw), Building 102, Brookley Complex South Broad Street Mobile, AL...

  7. Power Line Technician. Second Edition. Module A. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This module is the first in a series that is designed to help students achieve greater professional and personal success as power line technicians. Each module represents one or more complete units of instruction with components organized into one instructor and one student "package": the instructor's manual and the student workbook. The…

  8. Magnetic fields dispersed by high-voltage power lines: an advanced evaluation method based on 3-D models of electrical lines and the territory.

    PubMed

    Andreuccetti, D; Zoppetti, N

    2004-01-01

    An advanced numerical evaluation tool is proposed for calculating the magnetic flux density dispersed by high-voltage power lines. When compared to existing software packages based on the application of standardized methods, this tool turned out to be particularly suitable for making accurate evaluations on vast portions of the territory, especially when the contribution of numerous aerial and/or underground lines must be taken into account. The aspects of the tool of greatest interest are (1) the interaction with an electronic archive of power lines, from which all the information necessary for the calculation is obtained; (2) the use of three-dimensional models of both the power lines and the territory crossed by these; (3) the direct interfacing with electronic cartography; and finally (4) the use of a representation procedure for the results that is based on contour maps. The tool had proven to be very useful especially for Environmental Impact Assessment procedures relative to new power lines.

  9. Large-Scale Habitat Corridors for Biodiversity Conservation: A Forest Corridor in Madagascar

    PubMed Central

    Ramiadantsoa, Tanjona; Ovaskainen, Otso; Rybicki, Joel; Hanski, Ilkka

    2015-01-01

    In biodiversity conservation, habitat corridors are assumed to increase landscape-level connectivity and to enhance the viability of otherwise isolated populations. While the role of corridors is supported by empirical evidence, studies have typically been conducted at small spatial scales. Here, we assess the quality and the functionality of a large 95-km long forest corridor connecting two large national parks (416 and 311 km2) in the southeastern escarpment of Madagascar. We analyze the occurrence of 300 species in 5 taxonomic groups in the parks and in the corridor, and combine high-resolution forest cover data with a simulation model to examine various scenarios of corridor destruction. At present, the corridor contains essentially the same communities as the national parks, reflecting its breadth which on average matches that of the parks. In the simulation model, we consider three types of dispersers: passive dispersers, which settle randomly around the source population; active dispersers, which settle only in favorable habitat; and gap-avoiding active dispersers, which avoid dispersing across non-habitat. Our results suggest that long-distance passive dispersers are most sensitive to ongoing degradation of the corridor, because increasing numbers of propagules are lost outside the forest habitat. For a wide range of dispersal parameters, the national parks are large enough to sustain stable populations until the corridor becomes severely broken, which will happen around 2065 if the current rate of forest loss continues. A significant decrease in gene flow along the corridor is expected after 2040, and this will exacerbate the adverse consequences of isolation. Our results demonstrate that simulation studies assessing the role of habitat corridors should pay close attention to the mode of dispersal and the effects of regional stochasticity. PMID:26200351

  10. Large-Scale Habitat Corridors for Biodiversity Conservation: A Forest Corridor in Madagascar.

    PubMed

    Ramiadantsoa, Tanjona; Ovaskainen, Otso; Rybicki, Joel; Hanski, Ilkka

    2015-01-01

    In biodiversity conservation, habitat corridors are assumed to increase landscape-level connectivity and to enhance the viability of otherwise isolated populations. While the role of corridors is supported by empirical evidence, studies have typically been conducted at small spatial scales. Here, we assess the quality and the functionality of a large 95-km long forest corridor connecting two large national parks (416 and 311 km2) in the southeastern escarpment of Madagascar. We analyze the occurrence of 300 species in 5 taxonomic groups in the parks and in the corridor, and combine high-resolution forest cover data with a simulation model to examine various scenarios of corridor destruction. At present, the corridor contains essentially the same communities as the national parks, reflecting its breadth which on average matches that of the parks. In the simulation model, we consider three types of dispersers: passive dispersers, which settle randomly around the source population; active dispersers, which settle only in favorable habitat; and gap-avoiding active dispersers, which avoid dispersing across non-habitat. Our results suggest that long-distance passive dispersers are most sensitive to ongoing degradation of the corridor, because increasing numbers of propagules are lost outside the forest habitat. For a wide range of dispersal parameters, the national parks are large enough to sustain stable populations until the corridor becomes severely broken, which will happen around 2065 if the current rate of forest loss continues. A significant decrease in gene flow along the corridor is expected after 2040, and this will exacerbate the adverse consequences of isolation. Our results demonstrate that simulation studies assessing the role of habitat corridors should pay close attention to the mode of dispersal and the effects of regional stochasticity.

  11. Power line characterization from an airborne data collection with a millimeter wave radar

    NASA Astrophysics Data System (ADS)

    Goshi, Darren S.; Bui, Long Q.

    2014-05-01

    Enhancing the operational safety of small, maneuverable rotorcraft has been a critical consideration in the development of next generation situational awareness sensor suites. From landing assistance to target detection and obstacle avoidance, millimeter wave radars have become the leading candidate for such solutions due to their ability to operate in degraded visual environments, whether it is weather, induced debris, or night conditions that must be dealt with. Power lines pose arguably the largest safety risk for helicopter operation due to their difficulty in detection and proper identification to support avoidance maneuvering, where even under perfect conditions they can be nearly invisible to the naked eye. The backscatter phenomenology from braided power lines has been well-studied and formulated in previous literature, albeit mainly in controlled laboratory settings or limited field trials. Subsequently, the ability to simply detect power lines at operational distances up to around 2 km has been demonstrated. In this work, an analysis is performed on the measureable characteristics of power lines captured in a representative operational environment for helicopters. The test location included a diverse set of power line configurations with surrounding ground and tower clutter, representing a realistic scenario. A radiometrically calibrated w-band real-beam FMCW sensor allows the study and estimation of target RCS, as well as evaluation against the developed theory. All analysis is performed on dynamically captured data from a helicopter, where platform dynamics and system stability also play a significant role in a processed result. Results from this work will aid the effective development of next generation situational awareness systems.

  12. Voltages induced on a power distribution line by overhead cloud lightning

    NASA Technical Reports Server (NTRS)

    Yacoub, Ziad; Rubinstein, Marcos; Uman, Martin A.; Thomson, Ewen M.; Medelius, Pedro J.

    1991-01-01

    Voltages induced by overhead cloud lightning on a 448 m open circuited power distribution line and the corresponding north-south component of the lightning magnetic field were simultaneously measured at the NASA Kennedy Space Center during the summer of 1986. The incident electric field was calculated from the measured magnetic field. The electric field was then used as an input to the computer program, EMPLIN, that calculated the voltages at the two ends of the power line. EMPLIN models the frequency domain field/power coupling theory found, for example, in Ianoz et al. The direction of the source, which is also one of the inputs to EMPLIN, was crudely determined from a three station time delay technique. The authors found reasonably good agreement between calculated and measured waveforms.

  13. A Bayesian Prediction Framework of Weather Based Power Line Damages in the Northeast

    NASA Astrophysics Data System (ADS)

    frediani, M.; Anagnostou, E. N.; Wanik, D.; Scerbo, D.

    2012-12-01

    This study aims to evaluate the predictability of damages to overhead power distribution lines from severe weather events in the New England area. During storms, trees and branches can come down and interact with power lines that results in significant interruptions to electricity distribution, causing major interruptions to residents and monetary losses to the utility company. In Connecticut, a densely forested state, severe winds and precipitation (in the form of rain and snow) from storms are key weather factors that challenge the power grid infrastructure vulnerability. Evaluating the local predictability of these impacts may aid local power utilities with crew allocation and preparedness during an event. A probabilistic approach to damage prediction caused by trees subjected to severe weather is being investigated in the region. This study specifically, explores the feasibility of applying Bayesian inversion technique to weather parameters by developing a damage decision tree composed of various meteorological and static parameters, like wind gust, precipitation (rain and snow accumulation and rates), high canopy forest density and tree trimming history for the power distribution lines. The resulting decision tree can be used as a Bayesian inversion database to predict the probability distribution of damages given a storm forecast. The Bayesian database is based on a historical data source provided by The Connecticut Light & Power Company (Connecticut's primary power utility) containing geographical information of trouble spots caused by thunderstorm and winter/snow-storm events; power line specifications and trimming history; and high-resolution model analysis of those storms. The analysis is based on a 2-sqkm model grid cropped over the state of Connecticut comprising a database of 3,307 pixels per storm. Each storm pixel is flagged to contain power line damages or no-damages. A total of 50 storm simulations is used to build the database. Pairs of

  14. Study of magnetic fields from power-frequency current on water lines.

    PubMed

    Lanera, D; Zapotosky, J E; Colby, J A

    1997-01-01

    The magnetic fields from power-frequency current flowing on water lines were investigated in a new approach that involved an area-wide survey in a small town. Magnetic fields were measured outside the residence under power cables and over water lines, and each residence was characterized as to whether it received water from a private well or the municipal water system. The magnetic field data revealed two statistical modes when they were related to water supply type. The data also showed that in the case of the high mode, the magnetic field remained constant along the line formed by power drop wires, at the back of the house, and the water hookup service, in front of the house, all the way to the street. The patterns are explained by the coincidence of measurement points and the presence of net current flowing on power mains, power drop conductors, residential plumbing, water service hookups, and water mains. These patterns, together with other characteristics of this magnetic field source, such as the gradual spatial fall-off of this field and the presence of a constant component in the time sequence, portray a magnetic field more uniform and constant in the residential environment than has been thought to exist. Such characteristics make up for the weakness of the source and make net current a significant source of exposure in the lives of individuals around the house, when human exposure to magnetic fields is assumed to be a cumulative effect over time. This, together with the bimodal statistical distribution of the residential magnetic field (related to water supply type), presents opportunities for retrospective epidemiological analysis. Water line type and its ability to conduct power-frequency current can be used as the historical marker for a bimodal exposure inference, as Wertheimer et al. have shown.

  15. Northeast Corridor improvement project draft environmental impact statement/report for electrification of Northwest Corridor, New Haven, CT. to Boston, MA. Volume 3. Technical appendices. Final report, September 1992-September 1993

    SciTech Connect

    Not Available

    1993-09-01

    The impacts of extending electrification on the National Railroad Passenger Corporation's (Amtrak) Northeast Corridor (NEC) from New Haven, Connecticut to Boston, Massachusetts are of direct concern to the Federal Railroad Administration (FRA). To improve rail service and increase ridership between New York and Boston, Amtrak proposes the electrification of the NEC main line between New Haven, CT and Boston, MA using an overhead 2 x 25,000 volt - 60 hertz power system. The volume Number III contains the detailed technical studies that were performed in order to identify and evaluate the environmental impacts of the proposed project. Some of these studies have been included entirely in the Draft Environmental Impact Statements-draft (DEIS/R) (Volume 1). The technical evaluations performed were based upon regulatory requirements as well as substantive issues raised by individuals and public agencies as part of the public participation program.

  16. Lifelines and Earthquake Hazards in the Interstate 5 Urban Corridor: Cottage Grove to Woodburn, Oregon

    USGS Publications Warehouse

    Barnett, E.A.; Weaver, C.S.; Meagher, K.L.; Wang, Z.; Madin, I.P.; Wang, M.; Haugerud, R.A.; Wells, R.E.; Ballantyne, D.B.; Darienzo, M.; ,

    2004-01-01

    The Interstate 5 highway corridor, stretching from Mexico to Canada, is not only the economic artery of the Pacific Northwest, but is also home to the majority of Oregonians and Washingtonians. Accordingly, most regional utility and transportation systems, such as railroads and electrical transmission lines, have major components in the I-5 corridor. The section of I-5 from Cottage Grove, Oregon, to Blaine, Washington, is rapidly urbanizing, with population growth and economic development centered around the cities of Eugene, Salem, Portland, Olympia, Tacoma, Seattle, Everett, and Bellingham. For the purposes of this map, we refer to this area as the I-5 Urban Corridor. This publicaton consists of two large sheets: A map and a text-and-figures poster.

  17. Final report: Prototyping a combustion corridor

    SciTech Connect

    Rutland, Christopher J.; Leach, Joshua

    2001-12-15

    The Combustion Corridor is a concept in which researchers in combustion and thermal sciences have unimpeded access to large volumes of remote computational results. This will enable remote, collaborative analysis and visualization of state-of-the-art combustion science results. The Engine Research Center (ERC) at the University of Wisconsin - Madison partnered with Lawrence Berkeley National Laboratory, Argonne National Laboratory, Sandia National Laboratory, and several other universities to build and test the first stages of a combustion corridor. The ERC served two important functions in this partnership. First, we work extensively with combustion simulations so we were able to provide real world research data sets for testing the Corridor concepts. Second, the ERC was part of an extension of the high bandwidth based DOE National Laboratory connections to universities.

  18. Multivariable time series prediction for the icing process on overhead power transmission line.

    PubMed

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters.

  19. INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

    SciTech Connect

    Jake P. Gentle; Kurt S Myers; Tyler B Phillips; Inanc Senocak; Phil Anderson

    2014-08-01

    Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

  20. Multivariable Time Series Prediction for the Icing Process on Overhead Power Transmission Line

    PubMed Central

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters. PMID:25136653

  1. Virginia Power's generic main steam-line-break DNBR (departure from nucleate boiling ratio) analysis

    SciTech Connect

    Anderson, R.C.; Harrell, J.R.; Erb, J.O.

    1990-06-01

    Virginia Power operates four nuclear reactors, two units each at the Surry and North Anna Power stations. The original operating licenses were based on acceptable analysis results of the accidents in the final safety analysis report (FSAR). The assumptions of these analyses must be verified on a reload basis. Included in these FSAR accidents is the main steam-line-break (MSLB) event. The plant FSARs describe the MSLB analyses, which is summarized as follows. The plant is assumed to be at hot zero power at end of life, when the moderator temperature coefficient (MTC) is most negative. The MSLB rapidly cools the secondary side, followed by a primary cooldown in one loop. The surge of cold water into the core, coupled with the negative MTC, results in high local power factors, which in turn can result in a violation of the departure from nucleate boiling ratio (DNBR) limit. The three-dimensional power distribution is calculated at several key state points. These distributions are then subjected to core thermal-hydraulic analysis by the COBRA code. The W-3 correlation is used to calculate the state-point DNBRs. Both the physics and the DNBR calculations have been repeated on a reload basis. As a result, Virginia Power has accumulated a reasonably large data base of MSLB DNBRs for both Surry and North Anna. Virginia Power now uses the power peaking factors criterion to verify that the MSLB analysis remains bounding on a reload basis.

  2. Extensive Sampling of Forest Carbon using High Density Power Line Lidar

    NASA Astrophysics Data System (ADS)

    Hampton, H. M.; Chen, Q.; Dye, D. G.; Hungate, B. A.

    2013-12-01

    unmanaged areas, using high point density lidar collected over transmission line corridors. The lidar metric of quadratic mean height guided our selection of field plots spanning the full range from low to high levels of aboveground biomass across the study region. Before model selection, we minimized two of the major sources of errors in lidar calibration: variance in tree allometry across landscapes and plot edge effects (spatial mismatch between field measurements and lidar points). We tested an assortment of model selection techniques and goodness of fit measures for deriving forest structural metrics of interest. For example, we obtained an R-squared value for aboveground biomass (Mg/ha) of 0.9 using stepwise regression. The forest metrics obtained are being used in the next stage of the project to parameterize biogeochemical models linking terrestrial carbon pools and atmospheric greenhouse gas exchanges.

  3. California air transportation study: A transportation system for the California Corridor of the year 2010

    NASA Technical Reports Server (NTRS)

    1989-01-01

    To define and solve the problems of transportation in the California Corrider in the year 2010, the 1989 California Polytechnic State University Aeronautical Engineering Senior Design class determined future corridor transportation needs and developed a system to meet the requirements. A market study, which included interpreting travel demand and gauging the future of regional and national air travel in and out of the corridor, allowed the goals of the project to be accurately refined. Comprehensive trade-off studies of several proposed transporation systems were conducted to determine which components would form the final proposed system. Preliminary design and further analysis were performed for each resulting component. The proposed system consists of three vehicles and a special hub or mode mixer, the Corridor Access Port (CAP). The vehicles are: (1) an electric powered aircraft to serve secondary airports and the CAP; (2) a high speed magnetic levitation train running through the CAP and the high population density areas of the corridor; and (3) a vertical takeoff and landing tilt rotor aircraft to serve both intercity and intrametropolitan travelers from the CAP and city vertiports. The CAP is a combination and an extension of the hub, mode mixer, and Wayport concepts. The CAP is an integrated part of the system which meets the travel demands in the corridor, and interfaces with interstate and international travel.

  4. 78 FR 65751 - Integrated Corridor Management Deployment Planning Grants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... Federal Highway Administration Integrated Corridor Management Deployment Planning Grants AGENCY: Federal... continue Integrated Corridor Management (ICM) development with their partners, such as arterial management.... The purpose of this program is to promote the integrated management and operations of...

  5. 35. OUTER DRAWBRIDGE, ENTRY TO THE PROTECTIVE CORRIDOR BETWEEN THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. OUTER DRAWBRIDGE, ENTRY TO THE PROTECTIVE CORRIDOR BETWEEN THE RAVELIN AND THE CASTILLO, AS SEEN FROM WITHIN THE CORRIDOR - Castillo de San Marcos, 1 Castillo Drive, Saint Augustine, St. Johns County, FL

  6. Interior, looking corridor connecting 511 to 515 into Medical Research ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior, looking corridor connecting 511 to 515 into Medical Research Library in 516. - Fitzsimons General Hospital, Central Service Building, North of Building No. 511, East of corridor connecting Building 511 to Building 515, Aurora, Adams County, CO

  7. K-Band Power Enbedded Transmission Line (ETL) MMIC Amplifiers for Satellite Communication Applications

    NASA Technical Reports Server (NTRS)

    Tserng, Hua-Quen; Ketterson, Andrew; Saunier, Paul; McCarty, Larry; Davis, Steve

    1998-01-01

    The design, fabrication, and performance of K-band high-efficiency, linear power pHEMT amplifiers implemented in Embedded Transmission Line (ETL) MMIC configuration with unthinned GaAs substrate and topside grounding are reported. A three-stage amplifier achieved a power-added efficiency of 40.5% with 264 mW output at 20.2 GHz. The linear gain is 28.5 dB with 1-dB gain compression output power of 200 mW and 31% power-added efficiency. The carrier-to-third-order intermodulation ratio is approx. 20 dBc at the 1-dB compression point. A RF functional yield of more than 90% has been achieved.

  8. Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

    NASA Technical Reports Server (NTRS)

    Jeffries, K. S.; Renz, D. D.

    1984-01-01

    A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

  9. Onboard power line conditioning system for an electric or hybrid vehicle

    DOEpatents

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  10. A Tesla-pulse forming line-plasma opening switch pulsed power generator

    NASA Astrophysics Data System (ADS)

    Novac, B. M.; Kumar, R.; Smith, I. R.

    2010-10-01

    A pulsed power generator based on a high-voltage Tesla transformer which charges a 3.85 Ω/55 ns water-filled pulse forming line to 300 kV has been developed at Loughborough University as a training tool for pulsed power students. The generator uses all forms of insulation specific to pulsed power technology, liquid (oil and water), gas (SF6), and magnetic insulation in vacuum, and a number of fast voltage and current sensors are implemented for diagnostic purposes. A miniature (centimeter-size) plasma opening switch has recently been coupled to the output of the pulse forming line, with the overall system comprising the first phase of a program aimed at the development of a novel repetitive, table-top generator capable of producing 15 GW pulses for high power microwave loads. Technical details of all the generator components and the main experimental results obtained during the program and demonstrations of their performance are presented in the paper, together with a description of the various diagnostic tools involved. In particular, it is shown that the miniature plasma opening switch is capable of reducing the rise time of the input current while significantly increasing the load power. Future plans are outlined in the conclusions.

  11. The ac power line protection for an IEEE 587 Class B environment

    NASA Technical Reports Server (NTRS)

    Roehr, W. D.; Clark, O. M.

    1984-01-01

    The 587B series of protectors are unique, low clamping voltage transient suppressors to protect ac-powered equipment from the 6000V peak open-circuit voltage and 3000A short circuit current as defined in IEEE standard 587 for Category B transients. The devices, which incorporate multiple-stage solid-state protector components, were specifically designed to operate under multiple exposures to maximum threat levels in this severe environment. The output voltage peaks are limited to 350V under maximum threat conditions for a 120V ac power line, thus providing adequate protection to vulnerable electronic equipment. The principle of operation and test performance data is discussed.

  12. Development of On-Line Monitoring Systems for High Temperature Components in Power Plants

    PubMed Central

    Zhang, Hongcai; Jia, Jiuhong; Wang, Ning; Hu, Xiaoyin; Tu, Shan-Tung; Zhou, Shaoping; Wang, Zhengdong

    2013-01-01

    To accurately detect deformation and extend the component life beyond the original design limits, structural safety monitoring techniques have attracted considerable attention in the power and process industries for decades. In this paper an on-line monitoring system for high temperature pipes in a power plant is developed. The extension-based sensing devices are amounted on straight pipes, T-Joints and elbows of a main steam pipeline. During on-site monitoring for more than two years, most of the sensors worked reliably and steadily. However, the direct strain gauge could not work for long periods because of the high temperature environment. Moreover, it is found that the installation and connection of the extensometers can have a significant influence on the measurement results. The on-line monitoring system has a good alarming function which is demonstrated by detecting a steam leakage of the header. PMID:24233026

  13. Attenuation Characteristic Modeling of Power-line Channel in Cargo Ships

    NASA Astrophysics Data System (ADS)

    Tsuzuki, Shinji; Ishii, Seiichiro; Nishioka, Jun; Yamada, Yoshio

    Power-line communication (PLC) based local area network (LAN) in cargo ships is one of the promising applications of the PLC technology. In this paper, the signal attenuation characteristic when transmitting with the differential-mode (DIF) and the common-mode (COM) has been modeled respectively to design the PLC network in a cargo ship. The characteristic has been analyzed from the measured transfer function of 440V power-line channels for reefer containers in two typical ships. The measured transfer function was averaged from 2M to 30MHz (or until the measurement limit frequency) and approximated by the number of branches and the length of a signal propagating route. The mean accuracy of the obtained approximation equations was ±4dB. The area where the signal attenuation of COM transmission is less than that of DIF transmission has been studied from the equations.

  14. A simple packet retransmission strategy for throughput and delay enhancement on power line communication channels

    SciTech Connect

    Onunga, J.O. ); Donaldson, R.W. . Dept. of Electrical Engineering)

    1993-07-01

    A new, simple, and effective communication protocol is developed and evaluated for use on power line distribution networks. The protocol involves retransmission of unacknowledged packets, which are sent in either single or multiple (N) copies in accordance with estimates of communication link quality. Multiple packet copies can be code combined at the receiver, using majority voting on each bit position, to reduce packet error rates. Adaptive link quality estimates are based on the receipt or absence of positive acknowledgements. Information throughput efficiency is calculated and N optimized in terms of system variables. Performance benefits of code combining are clearly demonstrated. The algorithm was implemented and tested using a five-station intrabuilding power line communications network operating at 1.2, 2.4, 4.8 and 9.6 kbit/s data rate. Substantial throughput and delay improvement occurred on poor quality links, without degrading performance on good links.

  15. 46 CFR 190.10-30 - Dead end corridors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Dead end corridors. 190.10-30 Section 190.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 190.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent,...

  16. 46 CFR 72.10-30 - Dead end corridors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Dead end corridors. 72.10-30 Section 72.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 72.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent, more than...

  17. 46 CFR 190.10-30 - Dead end corridors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Dead end corridors. 190.10-30 Section 190.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 190.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent,...

  18. 46 CFR 92.10-30 - Dead end corridors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Dead end corridors. 92.10-30 Section 92.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 92.10-30 Dead end corridors. (a) Dead end corridors, or...

  19. 46 CFR 72.10-30 - Dead end corridors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Dead end corridors. 72.10-30 Section 72.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 72.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent, more than...

  20. 46 CFR 92.10-30 - Dead end corridors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Dead end corridors. 92.10-30 Section 92.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 92.10-30 Dead end corridors. (a) Dead end corridors, or...

  1. 46 CFR 72.10-30 - Dead end corridors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Dead end corridors. 72.10-30 Section 72.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 72.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent, more than...

  2. 46 CFR 190.10-30 - Dead end corridors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Dead end corridors. 190.10-30 Section 190.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 190.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent,...

  3. 46 CFR 72.10-30 - Dead end corridors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Dead end corridors. 72.10-30 Section 72.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 72.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent, more than...

  4. 46 CFR 92.10-30 - Dead end corridors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Dead end corridors. 92.10-30 Section 92.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 92.10-30 Dead end corridors. (a) Dead end corridors, or...

  5. 46 CFR 92.10-30 - Dead end corridors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Dead end corridors. 92.10-30 Section 92.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 92.10-30 Dead end corridors. (a) Dead end corridors, or...

  6. 46 CFR 190.10-30 - Dead end corridors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Dead end corridors. 190.10-30 Section 190.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 190.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent,...

  7. 45 CFR 153.540 - Compliance with risk corridors standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with risk corridors standards. HHS or its designee may audit a QHP issuer to assess its compliance with... 45 Public Welfare 1 2014-10-01 2014-10-01 false Compliance with risk corridors standards. 153.540... CARE ACCESS STANDARDS RELATED TO REINSURANCE, RISK CORRIDORS, AND RISK ADJUSTMENT UNDER THE...

  8. 46 CFR 190.10-30 - Dead end corridors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Dead end corridors. 190.10-30 Section 190.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 190.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent,...

  9. 46 CFR 72.10-30 - Dead end corridors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Dead end corridors. 72.10-30 Section 72.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 72.10-30 Dead end corridors. (a) Dead end corridors, or the equivalent, more than...

  10. 46 CFR 92.10-30 - Dead end corridors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dead end corridors. 92.10-30 Section 92.10-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS CONSTRUCTION AND ARRANGEMENT Means of Escape § 92.10-30 Dead end corridors. (a) Dead end corridors, or...

  11. 76 FR 72029 - Multistate Corridor Operations and Management Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ... Federal Highway Administration Multistate Corridor Operations and Management Program AGENCY: Federal... Corridor Operations and Management Program as authorized in 23 U.S.C. 511. This notice and correction... eligible entities interested in participating in the FHWA Multistate Corridor Operations and...

  12. High Power, Pulsed, RF Generation from Nonlinear Lumped Element Transmission Lines (NLETLs)

    DTIC Science & Technology

    2011-02-05

    attracted interest, most recently silicon carbide ( SiC ) and gallium nitride1 (GaN). A fundamental and important limitation of solid-state power...quite high. Wide band-gap semiconductor materials such as SiC and GaN break down at a higher voltage and are hence able to operate with lower...Voltage Experiments matched diodes created from the same silicon wafer, which was coincident ally useful for certain multiple line NLETL configurations

  13. Analysis of the grounding system for a mobile communication site placed on HV power line mast

    NASA Astrophysics Data System (ADS)

    Bîrsan, I.; Munteanu, C.; Horgoș, M.; Ilut, T.

    2016-08-01

    This paper aims to analyze the potential distribution on the soil surface or potential variation on the main directions inside computing mobile site. I want to study a system made the earth a mobile communications site, antennas operator and the system of which the earth is placed on a High Voltage Power Line Mast (LEA 110 KV). I made direct measurements and I use a 3D software for analyze the results and simulating some possible solutions.

  14. Horizontal cryogenic bushing for the termination of a superconducting power-transmission line

    DOEpatents

    Minati, K.F.; Morgan, G.H.; McNerney, A.J.; Schauer, F.

    1982-07-29

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminated the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  15. Termination for a superconducting power transmission line including a horizontal cryogenic bushing

    DOEpatents

    Minati, Kurt F.; Morgan, Gerry H.; McNerney, Andrew J.; Schauer, Felix

    1984-01-01

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  16. High-average-power narrow-line-width sum frequency generation 589 nm laser

    NASA Astrophysics Data System (ADS)

    Lu, Yanhua; Fan, Guobin; Ren, Huaijin; Zhang, Lei; Xu, Xiafei; Zhang, Wei; Wan, Min

    2015-10-01

    An 81 W average-power all-solid-state sodium beacon laser at 589 nm with a repetition rate of 250 Hz is introduced, which is based on a novel sum frequency generation idea between two high-energy, different line widths, different beam quality infrared lasers (a 1064 nm laser and a 1319 nm laser). The 1064 nm laser, which features an external modulated CW single frequency seed source and two stages of amplifiers, can provide average-power of 150 W, beam quality M2 of ~1.8 with ultra-narrow line width (< 100 kHz). The 1319 nm laser can deliver average-power of 100 W, beam quality M2 of ~3.0 with a narrow line width of ~0.3 GHz. By sum frequency mixing in a LBO slab crystal (3 mm x 12 mm x 50 mm), pulse energy of 325 mJ is achieved at 589 nm with a conversion efficiency of 32.5 %. Tuning the center wavelength of 1064 nm laser by a PZT PID controller, the target beam's central wavelength is accurately locked to 589.15910 nm with a line width of ~0.3 GHz, which is dominated mainly by the 1319 nm laser. The beam quality is measured to be M2 < 1.3. The pulse duration is measured to be 150 μs in full-width. To the best of our knowledge, this represents the highest average-power for all-solid-state sodium beacon laser ever reported.

  17. Radiatively driven winds for different power law spectra. [for explaining narrow and broad quasar absorption lines

    NASA Technical Reports Server (NTRS)

    Beltrametti, M.

    1980-01-01

    The analytic solutions for radiatively driven winds are given for the case in which the winds are driven by absorption of line and continuum radiation. The wind solutions are analytically estimated for different parameters of the central source and for different power law spectra. For flat spectra, three sonic points can exist; it is shown, however, that only one of these sonic points is physically realistic. Parameters of the central source are given which generate winds of further interest for explaining the narrow and broad absorption lines in quasars. For the quasar model presented here, winds which could give rise to the narrow absorption lines are generated by central sources with parameters which are not realistic for quasars.

  18. Development of Getting Up Detection and Report Device using Power Line Communication and Mat-Sensor

    NASA Astrophysics Data System (ADS)

    Haruyama, Kazuo; Tanaka, Kanya; Kobayashi, Shigeki; Yasuoka, Katsunori; Uchibori, Akihiko; Oka, Masato

    In this paper, we propose the getting up detection and report device which can be installed in middle-small facilities and ordinary houses. This device combines a mat sensor which detects rising and a power line communication (PLC) device as a reporting system. This device does not need any additional construction for installation as long as facilities equip electric power supply 100V for ordinary businesses. At first, the mat sensor in the system detects rising of an elderly person or lying down to bed. The PLC system sends ON/OFF signal and reports to nurses and staff members in their rooms. Since the main objective of the PLC system is to keep exact detection and transmission of the mat-sensor ON/OFF signal, high-speed network is not necessary. It is required that the system should be robust against noises of household electrical appliances. We used the selected-career method as a transmission method in which we located 2 lines of tone frequency (132kHz or 115kHz) for the power line transmission in the device. The effectiveness of the proposed device has been confirmed by the field experiments in welfare facilities for elderly people.

  19. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjiv; Kumar, Narendra

    2016-07-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  20. Design and fabrication of the high-power RF transmission line into the PEFP linac tunnel

    NASA Astrophysics Data System (ADS)

    Seol, Kyung-Tae; Kwon, Hyeok-Jung; Kim, Han-Sung; Cho, Yong-Sub

    2012-07-01

    The 100-MeV proton linear accelerator (linac) for the Proton Engineering Frontier Project (PEFP) has been developed and will be installed at the Gyeong-ju site. For the linac, a total of 11 sets of RF systems are required, and the waveguide layout was fixed to install high-power RF (HPRF) systems. One of the important interfaces with the building construction is the high-power radio-frequency (HPRF) transmission line embedded in the tunnel, which is used to transmit 1-MW RF power to each cavity in the tunnel. The waveguide section penetrating into the linac tunnel was designed with a bending structure for radiation shielding, and the dependence of its voltage standing-wave ratio (VSWR) on the chamfer length of the bending was calculated. The HPRF transmission line was fabricated into a piece of waveguide to prevent moisture and any foreign debris inside the 2.5-m thick concrete block. Air leakage was checked with a pressure of 0.25 psig of nitrogen gas, and a maximum VSWR of 1.196 was obtained by measuring the vector reflection coefficients with the quarter-wave transmission section. In this paper, the design and the fabrication of the HPRF transmission line into the PEFP linac tunnel are presented.

  1. Electromagnetic fields and cancer in children residing near Norwegian high-voltage power lines.

    PubMed

    Tynes, T; Haldorsen, T

    1997-02-01

    The aim of the nested case-control study reported here was to test the hypothesis that exposure to electromagnetic fields of the type generated by high-voltage power lines increases the incidence of cancer in children aged 0-14 years. The study population comprised children who during at least one of the years 1960, 1970, 1980, 1985, 1987, or 1989 had lived in a census ward crossed by a high-voltage power line. The cases were diagnosed from 1965 to 1989 and were matched to controls by year of birth, sex, and municipality. Exposure to electric and magnetic fields was calculated by means of computer programs in which power line characteristics and distance were taken into account. No association was found between exposure to time-weighted average exposure to magnetic fields and cancer at all sites, brain tumors, lymphoma, or leukemia. Cancer at other sites showed elevated odds ratios in the two highest exposure categories in some, but not all, measures of exposure. This study provides little support for an association between children's exposure to magnetic fields and cancer and no support for an association between leukemia and such exposure, but no firm conclusions can be drawn owing to the small numbers involved.

  2. Performance Of The DIII-D ECH High Power Transmission Lines And Launching Systems

    NASA Astrophysics Data System (ADS)

    Cengher, Mirela; Lohr, J.; Gorelov, Y.; Torrezan, A.; Ponce, D.; Moeller, C.; Ellis, R. A.; Kolemen, E.

    2015-11-01

    The Electron Cyclotron Heating (ECH) transmission system on the DIII D tokamak consists of corrugated coaxial 31.75 mm waveguide transmission lines and steerable launching mirrors. Total power injected into plasma can reach up to 3.5 MW, with pulse length up to 5 seconds. The ECH power injected to the tokamak from each gyrotron is measured on a shot-to-shot basis and shows individual average injected powers from a gyrotron into the plasma between 540 and 700 kW. The transmission coefficient including the waveguide line and the MOU is between -1.04 dB and -1.43 dB. The maximum ECH energy injected into DIII-D is 16.6 MJ. The HE11 mode content is over 85 % for all the lines. The four dual waveguide launchers have increased poloidal scanning speed, and can steer the RF beams 40 degrees poloidally in 200 ms, with real-time poloidal motion control by the plasma control system. A new method of in-situ calibration of the mirror angle was used in conjunction with the upgrading of the encoders and motors for the launchers. Work supported by US DOE under DE-FC02-04ER54698 and DE-AC02-09CH11466.

  3. Distributed Power-Line Outage Detection Based on Wide Area Measurement System

    PubMed Central

    Zhao, Liang; Song, Wen-Zhan

    2014-01-01

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches. PMID:25051035

  4. Distributed power-line outage detection based on wide area measurement system.

    PubMed

    Zhao, Liang; Song, Wen-Zhan

    2014-07-21

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches.

  5. 36 CFR 13.1108 - Alsek Corridor.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Alsek Corridor. 13.1108 Section 13.1108 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR NATIONAL PARK SYSTEM UNITS IN ALASKA Special Regulations-Glacier Bay National Park and...

  6. A Novel Uniform Discrete Multitone Transceiver with Power-Allocation for Digital Subscriber Line

    NASA Astrophysics Data System (ADS)

    Baig, Sobia; Junaid Mughal, Muhammad

    A novel Uniform Discrete Multitone (DMT) transceiver is proposed, utilizing a wavelet packet based filter bank transmultiplexer in conjunction with a DMT transceiver. The proposed transceiver decomposes the channel spectrum into subbands of equal bandwidth. The objective is to minimize the bit error rate (BER), which is increased by channel-noise amplification. This noise amplification is due to the Zero-Forcing equalization (ZFE) technique. Quantization of the channel-noise amplification is presented, based on post-equalization signal-to-noise ratio (SNR) and probability of error in all subbands of the Uniform DMT system. A modified power loading algorithm is applied to allocate variable power according to subband gains. A BER performance comparison of the Uniform DMT with variable and uniform power-loading and with a conventional DMT system in a Digital Subscriber Line (DSL) channel is presented.

  7. Remote sensing impact on corridor selection and placement

    NASA Technical Reports Server (NTRS)

    Thomson, F. J.; Sellman, A. N.

    1975-01-01

    Computer-aided corridor selection techniques, utilizing digitized data bases of socio-economic, census, and cadastral data, and developed for highway corridor routing are considered. Land resource data generated from various remote sensing data sources were successfully merged with the ancillary data files of a corridor selection model and prototype highway corridors were designed using the combined data set. Remote sensing derived information considered useful for highway corridor location, special considerations in geometric correction of remote sensing data to facilitate merging it with ancillary data files, and special interface requirements are briefly discussed.

  8. Corridors Increase Plant Species Richness at Large Scales

    SciTech Connect

    Damschen, Ellen I.; Haddad, Nick M.; Orrock,John L.; Tewksbury, Joshua J.; Levey, Douglas J.

    2006-09-01

    Habitat fragmentation is one of the largest threats to biodiversity. Landscape corridors, which are hypothesized to reduce the negative consequences of fragmentation, have become common features of ecological management plans worldwide. Despite their popularity, there is little evidence documenting the effectiveness of corridors in preserving biodiversity at large scales. Using a large-scale replicated experiment, we showed that habitat patches connected by corridors retain more native plant species than do isolated patches, that this difference increases over time, and that corridors do not promote invasion by exotic species. Our results support the use of corridors in biodiversity conservation.

  9. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    SciTech Connect

    Uman, M.A.; Rubinstein, M.; Yacoub, Z.

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  10. Real-time simulation of power transmission lines using Marti model with optimal fitting on dual-DSP card

    SciTech Connect

    Dufour, C.; Le-Huy, H.; El Hakimi, A.; Soumagne, J.C.

    1996-01-01

    Real-time simulation of a small power network containing a Marti modeled transmission line is made using 2 parallel DSP`s. A new fitting method is used in the modeling of the Marti line which is optimized with regards to the fitting error curve. Results are presented which show the time costs of the Marti line modeling versus constant-parameter line modeling and the time savings by using two parallel DSP`s.

  11. River-Corridor Habitat Dynamics, Lower Missouri River

    USGS Publications Warehouse

    Jacobson, Robert B.

    2010-01-01

    Intensive management of the Missouri River for navigation, flood control, and power generation has resulted in substantial physical changes to the river corridor. Historically, the Missouri River was characterized by a shifting, multithread channel and abundant unvegetated sandbars. The shifting channel provided a wide variety of hydraulic environments and large areas of connected and unconnected off-channel water bodies. Beginning in the early 1800s and continuing to the present, the channel of the Lower Missouri River (downstream from Sioux City, Iowa) has been trained into a fast, deep, single-thread channel to stabilize banks and maintain commercial navigation. Wing dikes now concentrate the flow, and revetments and levees keep the channel in place and disconnect it from the flood plain. In addition, reservoir regulation of the Missouri River upstream of Yankton, South Dakota, has substantially changed the annual hydrograph, sediment loads, temperature regime, and nutrient budgets. While changes to the Missouri River have resulted in broad social and economic benefits, they have also been associated with loss of river-corridor habitats and diminished populations of native fish and wildlife species. Today, Missouri River stakeholders are seeking ways to restore some natural ecosystem benefits of the Lower Missouri River without compromising traditional economic uses of the river and flood plain.

  12. An interactive 2-D power-line modeling and simulation tool

    NASA Astrophysics Data System (ADS)

    Hull, David; Adelman, Ross

    2012-06-01

    The U.S. Army Research Laboratory's Power-Line unmanned aerial vehicle (UAV) Modeling and Simulation (ARL-PLUMS) is a tool for estimating and analyzing quasi-static electric and magnetic fields due to power lines. This tool consists of an interactive 2-D graphical user interface (GUI) and a compute engine that can be used to calculate and visualize the E-Field and H-Field due to as many as seven conductors (two 3-phase circuits and a ground wire). ARL-PLUMS allows the user to set the geometry of the lines and the load conditions on those lines, and then calculate Ey, Ez, Hy, or Hz along a linear path or cutting plane, or in the form of a movie. The path can be along the ground or in the air to simulate the fields that might be observed, for example, by a robotic vehicle or a UAV. ARL-PLUMS makes several simplifying assumptions in order to allow simulations to be completed on a laptop PC interactively. In most cases, the results are excellent, providing a "90% solution" in just a few minutes of total modeling and simulation time. This paper describes the physics used by ARL-PLUMS, including the simplifying assumptions and the 2-D Method of Moments solver. Examples of electric and magnetic fields for different wire configurations, including typical 3-phase distribution and transmissions lines, are provided. Comparisons to similar results using a full 3-D model are also shown, and a discussion of errors that may be expected from the 2-D simulations is provided.

  13. RISK CORRIDORS AND REINSURANCE IN HEALTH INSURANCE MARKETPLACES

    PubMed Central

    LAYTON, TIMOTHY J.; MCGUIRE, THOMAS G.; SINAIKO, ANNA D.

    2016-01-01

    Health Insurance Marketplaces established by the Affordable Care Act implement reinsurance and risk corridors. Reinsurance limits insurer costs associated with specific individuals, while risk corridors protect against aggregate losses. Both tighten the insurer’s distribution of expected costs. This paper compares the economic costs and consequences of reinsurance and risk corridors. We simulate the insurer’s cost distribution under reinsurance and risk corridors using data for a group of individuals likely to enroll in Marketplace plans from the Medical Expenditure Panel Survey. We compare reinsurance and risk corridors in terms of risk reduction and incentives for cost containment. We find that reinsurance and one-sided risk corridors achieve comparable levels of risk reduction for a given level of incentives. We also find that the policies being implemented in the Marketplaces (a mix of reinsurance and two-sided risk corridor policies) substantially limit insurer risk but perform similarly to a simpler stand-alone reinsurance policy. PMID:26973861

  14. Transmission Line Security Monitor: Final Report

    SciTech Connect

    John Svoboda

    2011-04-01

    The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

  15. Intelligent Video Surveillance for Detecting Snow and Ice Coverage on Electrical Insulators of Power Transmission Lines

    NASA Astrophysics Data System (ADS)

    Gu, Irene Y. H.; Sistiaga, Unai; Berlijn, Sonja M.; Fahlström, Anders

    One of the problems for electrical power delivery through power lines in northern countries is when snow or ice accumulates on electrical insulators. This could lead to snow or ice-induced outages and voltage collapse, causing huge economic loss. This paper proposes a novel real-time intelligent surveillance and image analysis system for detecting and estimating the snow and ice coverage on electric insulators using images captured from an outdoor 420 kV power transmission line. In addition, the swing angle of insulators is estimated, as large swing angles due to wind cause short circuits. Hybrid techniques by combining histogram, edges, boundaries and cross-correlations are employed for handling a broad range of scenarios caused by changing weather and lighting conditions. Experiments have been conducted on the captured images over several month periods. Results have shown that the proposed system has provided valuable estimation results. For image pixels related to snows on the insulator, the current system has yielded an average detection rate of 93% for good quality images, and 67.6% for images containing large amount of poor quality ones, and the corresponding average false alarm ranges from 9% to 18.1%. Further improvement may be achieved by using video-based analysis and improved camera settings.

  16. Design method for a laser line beam shaper of a general 1D angular power distribution

    NASA Astrophysics Data System (ADS)

    Oved, E.; Oved, A.

    2016-05-01

    Laser line is a beam of laser, spanned in one direction using a beam shaper to form a fan of light. This illumination tool is important in laser aided machine vision, 3D scanners, and remote sensing. For some applications the laser line should have a specific angular power distribution. If the distribution is nonsymmetrical, the beam shaper is required to be nonsymmetrical freeform, and its design process using optical design software is time consuming due to the long optimization process which usually converges to some local minimum. In this paper we introduce a new design method of a single element refractive beam shaper of any predefined general 1D angular power distribution. The method makes use of a notion of "prism space", a geometrical representation of all double refraction prisms, and any 1D beam shaper can be described by a continuous curve in this space. It is shown that infinitely many different designs are possible for any given power distribution, and it is explained how an optimal design is selected among them, based on criteria such as high transmission, low surface slopes, robustness to manufacturing errors etc. The method is non-parametric and hence does not require initial guess of a functional form, and the resultant optical surfaces are described by a sequence of points, rather than by an analytic function.

  17. A proposal to Improve Electric Power Transmission Efficiency of the Transmission line from Yekepa to Buchanan of the CLSG Power System Redevelopment Interconnection Project Using FACTS Devices

    NASA Astrophysics Data System (ADS)

    Jackson, Samuel Mulbah

    This Work examined improving the electric power transmission efficiency of a portion of the CLSG (Cote d'Ivoire, Liberia, Sierra Leone, and Guinea) Interconnection Redevelopment Project of 1141 km high voltage transmission line. As with all ac transmission, present, new, and upgraded, they exhibit four electrical properties: resistance, inductance, capacitance, and conductance. These parameters affect the transmission line's ability to fulfil its function as part of the power system. A transmission system functions are to transport electric power from a generating source to a central point, to transport bulk power from a central point to wholesale delivery points (sub transmission substations), and to act as a tie points with interconnecting transmission lines from other power systems for emergency or economic reasons. In this work a portion of the CLSG Interconnection was simulated in MATLAB using different loading conditions. In determining voltage, current, and power, all sending end and receiving end quantities were determined at different sending end power levels. This was done on an incremental basis starting from 25 MW to 300 MW at 0.8 power factor. The results obtained from these produced data that were then used to plot graphs, among them the voltage profiles of the line at different loading conditions. The line loadability curves produced at different loading conditions were also plotted. So these curves provided illumination on the behavior and deficiencies of the line. Those deficiencies meant that there was a need for modification so as to keep the system in a safe operating voltage condition at different loading conditions. The line was compensated where needed, employing shunt capacitive compensation under different loading conditions for the purpose of making the receiving end voltage equal with the sending end voltage or within usable voltage levels. The line compensation provided a flat voltage profile at those loading conditions.

  18. Implications of Field Line Tracing for Power and Particle Handling in NCSX

    NASA Astrophysics Data System (ADS)

    Grossman, A.; Mioduszewki, P. K.

    2002-11-01

    Recent experience with power and particle handling in W7-AS shows that there is substantial improvement when the plasma-wall interaction is systematized with the use of a divertor. The improvements with a divertor include achievement of record values of beta, increases in energy confinement with density, decreases in impurity and particle confinement and full density control. With the healing of islands just inside the LCMS of NCSX, the finite beta tracing of field lines outside of the LCMS via the MFBE_2001 code shows that a sufficiently long connection length (>100m) can be achieved to yield a temperature separation between divertor and LCMS sufficiently large for divertor operation. Significant flux expansion and stochastic field line structure with Kolmogorov lengths measuring several toroidal revolutions suggests that the divertor is a feasible option for NCSX.

  19. Solving Man-Induced Large-Scale Conservation Problems: The Spanish Imperial Eagle and Power Lines

    PubMed Central

    López-López, Pascual; Ferrer, Miguel; Madero, Agustín; Casado, Eva; McGrady, Michael

    2011-01-01

    Background Man-induced mortality of birds caused by electrocution with poorly-designed pylons and power lines has been reported to be an important mortality factor that could become a major cause of population decline of one of the world rarest raptors, the Spanish imperial eagle (Aquila adalberti). Consequently it has resulted in an increasing awareness of this problem amongst land managers and the public at large, as well as increased research into the distribution of electrocution events and likely mitigation measures. Methodology/Principal Findings We provide information of how mitigation measures implemented on a regional level under the conservation program of the Spanish imperial eagle have resulted in a positive shift of demographic trends in Spain. A 35 years temporal data set (1974–2009) on mortality of Spanish imperial eagle was recorded, including population censuses, and data on electrocution and non-electrocution of birds. Additional information was obtained from 32 radio-tracked young eagles and specific field surveys. Data were divided into two periods, before and after the approval of a regional regulation of power line design in 1990 which established mandatory rules aimed at minimizing or eliminating the negative impacts of power lines facilities on avian populations. Our results show how population size and the average annual percentage of population change have increased between the two periods, whereas the number of electrocuted birds has been reduced in spite of the continuous growing of the wiring network. Conclusions Our results demonstrate that solving bird electrocution is an affordable problem if political interest is shown and financial investment is made. The combination of an adequate spatial planning with a sustainable development of human infrastructures will contribute positively to the conservation of the Spanish imperial eagle and may underpin population growth and range expansion, with positive side effects on other endangered

  20. On-Line Condition Monitoring of a Power Transmission Unit of a Rail Vehicle

    NASA Astrophysics Data System (ADS)

    Deuszkiewicz, P.; Radkowski, S.

    2003-11-01

    The paper addresses the issue of selection of diagnostic parameters and methods of an object's condition classification. The research was conducted for a power transmission unit of a commuter train. We analysed the vibration of the axle box as measured on the track for systems before and after an overhaul. In the final part of the paper, we proposed an algorithm that can be used to identify the technical condition of a machine while using neural networks and we also described the operation of an on-line diagnostic system.

  1. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    NASA Astrophysics Data System (ADS)

    Zohar, S.; Kissick, D. J.; Venugopalan, N.; Ogata, C. M.; Makarov, O.; Stepanov, S.; Fischetti, R. F.

    2016-09-01

    Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam's susceptibility to higher frequency position oscillations. In this article, we show that a 1 μ m amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  2. Oceanic Situational Awareness Over the Pacific Corridor

    NASA Technical Reports Server (NTRS)

    Welch, Bryan; Greenfeld, Israel

    2005-01-01

    Air traffic control (ATC) mandated, aircraft separations over the oceans impose a limitation on traffic capacity for a given corridor, given the projected traffic growth over the Pacific Ocean. The separations result from a lack of acceptable situational awareness over oceans where radar position updates are not available. This study considers the use of Automatic Dependent Surveillance (ADS) data transmitted over a commercial satellite communications system as an approach to provide ATC with the needed situational awareness and thusly allow for reduced aircraft separations. This study uses Federal Aviation Administration data from a single day for the Pacific Corridor to analyze traffic loading to be used as a benchmark against which to compare several approaches for coordinating data transmissions from the aircraft to the satellites.

  3. Calculating toxic corridors. Revision. Technical report

    SciTech Connect

    Kahler, J.P.; Curry, R.G.; Kandler, R.A.

    1989-04-01

    Method for defining evacuation areas for accidental spills of toxic chemicals are presented. These spills can present serious health hazards to people exposed to excessive vapor concentrations downwind of the accident. An empirical diffusion equation is used to calculate the downwind hazard distance. The width of the toxic corridor, specified in angular degrees centered along the mean wind direction, is based upon the variability of the wind direction. Flexibility in estimating toxic corridor evacuation areas is allowed through a choice of four different methods involving the use of tables, nomograms, and a programmable calculator. Appendices present worksheets, example problems, procedures for determining meteorological units, a procedure for determining evaporative source strength, and other items.

  4. Achieving EMC Emissions Compliance for an Aeronautics Power Line Communications System

    NASA Astrophysics Data System (ADS)

    Dominiak, S.; Vos, G.; ter Meer, T.; Widmer, H.

    2012-05-01

    Transmitting data over the power distribution network - Power Line Communications (PLC) -provides an interesting solution to reducing the weight and complexity of wiring networks in commercial aircraft. One of the potential roadblocks for the introduction of this technology is achieving EMC emissions compliance. In this article an overview of the EMC conducted and radiated emissions testing for PLC- enabled aeronautics equipment is presented. Anomalies resulting from chamber resonances leading to discrepancies between the conducted emissions tests and the measured radiated emissions are identified and described. Measurements made according to the current version of the civil aeronautical EMC standard, EUROCAE ED-14F (RTCA DO-160F), show that PLC equipment can achieve full EMC emissions compliance.

  5. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    NASA Astrophysics Data System (ADS)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  6. Corridors affect plants, animals, and their interactions in fragmented landscapes.

    SciTech Connect

    Tewksbury, Joshua, J.; Levey, Douglas, J.; Haddad, Nick, M.; Sargent, Sarah; Orrock, John, L.; Weldon, Aimee; Danielson, Brent, J.; Brinkerhoff, Jory; Damschen, Ellen, I.; Townsend, Patricia

    2002-10-01

    Tewksbury, J.J., D.J. Levey, N.M. Haddad, S. Sargent, J.L. Orrock, A. Weldon, B.J. Danielson, J. Brinkerhoff, E.I. Damschen, and P. Townsend. 2002. Corridors affect plants, animals, and their interactions in fragmented landscapes. PNAS 99(20):12923-12926. Among the most popular strategies for maintaining populations of both plants and animals in fragmented landscapes is to connect isolated patches with thin strips of habitat, called corridors. Corridors are thought to increase the exchange of individuals between habitat patches, promoting genetic exchange and reducing population fluctuations. Empirical studies addressing the effects of corridors have either been small in scale or have ignored confounding effects of increased habitat area created by the presence of a corridor. These methodological difficulties, coupled with a paucity of studies examining the effects of corridors on plants and plant-animal interactions, have sparked debate over the purported value of corridors in conservation planning. We report results of a large-scale experiment that directly address this debate. We demonstrate that corridors not only increase the exchange of animals between patches, but also facilitate two key plant-animal interactions: pollination and seed dispersal. Our results show that the beneficial effects of corridors extend beyond the area they add, and suggest that increased plant and animal movement through corridors will have positive impacts on plant populations and community interactions in fragmented landscapes.

  7. Corridors promote fire via connectivity and edge effects.

    PubMed

    Brudvig, Lars A; Wagner, Stephanie A; Damschen, Ellen I

    2012-04-01

    Landscape corridors, strips of habitat that connect otherwise isolated habitat patches, are commonly employed during management of fragmented landscapes. To date, most reported effects of corridors have been positive; however, there are long-standing concerns that corridors may have unintended consequences. Here, we address concerns over whether corridors promote propagation of disturbances such as fire. We collected data during prescribed fires in the world's largest and best replicated corridor experiment (Savannah River Site, South Carolina, USA), six -50-ha landscapes of open (shrubby/herbaceous) habitat within a pine plantation matrix, to test several mechanisms for how corridors might influence fire. Corridors altered patterns of fire temperature through a direct connectivity effect and an indirect edge effect. The connectivity effect was independent of fuel levels and was consistent with a hypothesized wind-driven "bellows effect." Edges, a consequence of corridor implementation, elevated leaf litter (fuel) input from matrix pine trees, which in turn increased fire temperatures. We found no evidence for corridors or edges impacting patterns of fire spread: plots across all landscape positions burned with similar probability. Impacts of edges and connectivity on fire temperature led to changes in vegetation: hotter-burning plots supported higher bunch grass cover during the field season after burning, suggesting implications for woody/herbaceous species coexistence. To our knowledge, this represents the first experimental evidence that corridors can modify landscape-scale patterns of fire intensity. Corridor impacts on fire should be carefully considered during landscape management, both in the context of how corridors connect or break distributions of fuels and the desired role of fire as a disturbance, which may range from a management tool to an agent to be suppressed. In our focal ecosystem, longleaf pine woodland, corridors might provide a previously

  8. High power microwave beam steering based on gyromagnetic nonlinear transmission lines

    SciTech Connect

    Romanchenko, I. V. Rostov, V. V.; Gunin, A. V.; Konev, V. Yu.

    2015-06-07

    We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

  9. A power line data communication interface using spread spectrum technology in home automation

    SciTech Connect

    Shwehdi, M.H.; Khan, A.Z.

    1996-07-01

    Building automation technology is rapidly developing towards more reliable communication systems, devices that control electronic equipments. These equipment if controlled leads to efficient energy management, and savings on the monthly electricity bill. Power Line communication (PLC) has been one of the dreams of the electronics industry for decades, especially for building automation. It is the purpose of this paper to demonstrate communication methods among electronic control devices through an AC power line carrier within the buildings for more efficient energy control. The paper outlines methods of communication over a powerline, namely the X-10 and CE bus. It also introduces the spread spectrum technology as to increase speed to 100--150 times faster than the X-10 system. The powerline carrier has tremendous applications in the field of building automation. The paper presents an attempt to realize a smart house concept, so called, in which all home electronic devices from a coffee maker to a water heater microwave to chaos robots will be utilized by an intelligent network whenever one wishes to do so. The designed system may be applied very profitably to help in energy management for both customer and utility.

  10. Current densities and total contact currents associated with 400 kV power line tasks.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo

    2013-12-01

    The aim of the study was to analyze all current values from measured periods while performing tasks on 400 kV power lines. Our aim was also to study the average current densities and average total contact currents caused by electric fields in 400 kV power line tasks. Two workers simulated the following tasks: (A) climbing up a portal tower, (B) climbing up a portal transposing tower, (C) working on the cross-arm of a portal tower, (D) climbing up a portal tube tower, (E) climbing up a Tannenbaum tower on the side of the energized circuit with the other circuit unenergized, (F) climbing up a Tannenbaum tower with both circuits energized, and (G) climbing up a Donau tower. The highest average current density in the neck was 2.5 mA/m(2) (calculated internal electric field 31.5-63.0 mV/m), and the highest average of the contact currents was 240.0 µA. All measured values at 400 kV towers were lower than the limit value of 10 mA/m(2) in the first version of Directive 2004/40/EC and the basic restrictions (0.1 and 0.8 V/m) of the International Commission on Non-ionizing Radiation Protection.

  11. Treatment of biodiversity issues in impact assessment of electricity power transmission lines: A Finnish case review

    SciTech Connect

    Soederman, Tarja . E-mail: tarja.soderman@ymparisto.fi

    2006-05-15

    The Environmental Impact Assessment (EIA) process concerning the route of a 400 kV power transmission line between Loviisa and Hikiae in southern Finland was reviewed in order to assess how biodiversity issues are treated and to provide suggestions on how to improve the effectiveness of treatment of biodiversity issues in impact assessment of linear development projects. The review covered the whole assessment process, including interviews of stakeholders, participation in the interest group meetings and review of all documents from the project. The baseline studies and assessment of direct impacts in the case study were detailed but the documentation, both the assessment programme and the assessment report, only gave a partial picture of the assessment process. All existing information, baseline survey and assessment methods should be addressed in the scoping phase in order to promote interaction between all stakeholders. In contrast to the assessment of the direct effects, which first emphasized impacts on the nationally important and protected flying squirrel but later expanded to deal with the assessment of impacts on ecologically important sites, the indirect and cumulative impacts of the power line were poorly addressed. The public was given the opportunity to become involved in the EIA process. However, they were more concerned with impacts on their properties and less so on biodiversity and species protection issues. This suggests that the public needs to become more informed about locally important features of biodiversity.

  12. The role of power line rights-of-way as an alternative habitat for declined mire butterflies.

    PubMed

    Lensu, Terhi; Komonen, Atte; Hiltula, Outi; Päivinen, Jussi; Saari, Veli; Kotiaho, Janne S

    2011-10-01

    Habitat loss is one of the greatest threats for biodiversity. In Finland, two thirds of natural mires have been drained for silviculture, which transforms open wetlands into dense forests. However, vegetation management of power line rights-of-way (ROW) maintain the drained mires as open areas. The aim of this study was to determine the effect of the power line ROW vegetation management on butterfly abundance, species richness and community structure by comparing the managed power line ROWs to unmanaged drained control sites and to natural mires. The species richness or abundance of mire butterflies did not differ between the power line ROWs and natural mires. In contrast, both species richness and abundance of butterflies was low on the unmanaged control sites. Tree canopy cover had a negative effect on mire butterflies and this is most likely related to changes in microclimate. The results indicate that the active vegetation removal in the power line ROWs maintain alternative habitats for mire butterflies; yet, the power line ROWs cannot substitute the natural mires.

  13. 75 FR 75170 - Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-02

    ... Rural Utilities Service Minnkota Power Cooperative, Inc.: Bemidji to Grand Rapids 230 kV Transmission... to Grand Rapids 230 kV Transmission Line Project (Project) in Beltrami, Hubbard, Itasca, and Cass... construct the 230 kilovolt (kV) transmission line between the Wilton Substation near Bemidji, Minnesota...

  14. 40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... line voltage and ambient temperature. 53.55 Section 53.55 Protection of Environment ENVIRONMENTAL... power line voltage and ambient temperature. (a) Overview. (1) This test procedure is a combined... temperature. Tests shall be conducted in a temperature-controlled environment over four 6-hour time...

  15. Power lines: Urban space, energy development and the making of the modern Southwest

    NASA Astrophysics Data System (ADS)

    Needham, Todd Andrew

    "Power Lines: Urban Space, Energy Development, and the Making of the Modern Southwest" explores the social and environmental transformation of the postwar Southwest and the resulting disputes between urban boosters, federal officials, Native Americans, and environmental activists. The dissertation focuses on the infrastructure built to provide the burgeoning populations of Phoenix, Los Angeles, and other Southwestern cities with electricity. This infrastructure allowed metropolitan boosters in the Southwest to attract Cold War defense manufacturing and to build a new suburban landscape even as industrialization on Indian lands provided electricity for those landscapes. Tracing the transition of electrical generation from a dispersed geography relying on local resources to a centralized geography utilizing primarily coal from Navajo land, "Power Lines" demonstrates the increasing centrality of Indian lands and labor to the metropolitan Southwest. Paying close attention to these networks reveals the far-reaching changes caused by postwar metropolitan growth. "Power Lines" challenges understandings of urban space that neglect the material resources that allow cities to "live." As the nation's cities and suburbs became increasingly energy-intensive, electrical utilities reached deep into the metropolitan periphery, transforming landscapes hundreds of miles from city centers into urban space. The construction of the new "geography of power" in the Southwest also reflects the impact of growth liberalism on postwar growth, as federal money funded suburban, manufacturing, and infrastructure developments. This pursuit of growth produced new political struggles, both as the development of energy resources conflicted with emerging environmentalist sensibilities and as American Indians increasingly resented the industrialization of their land for the benefit of others. By the 1970s, the simultaneous pursuit and criticism of growth came to define the modern Southwest. The

  16. A fast, robust algorithm for power line interference cancellation in neural recording

    NASA Astrophysics Data System (ADS)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed

  17. On-line calibration of process instrumentation channels in nuclear power plants

    SciTech Connect

    Hashemian, H.M.; Farmer, J.P.

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  18. Seasonal and Local Characteristics of Lightning Outages of Power Distribution Lines in Hokuriku Area

    NASA Astrophysics Data System (ADS)

    Sugimoto, Hitoshi; Shimasaki, Katsuhiko

    The proportion of the lightning outages in all outages on Japanese 6.6kV distribution lines is high with approximately 20 percent, and then lightning protections are very important for supply reliability of 6.6kV lines. It is effective for the lightning performance to apply countermeasures in order of the area where a large number of the lightning outages occur. Winter lightning occurs in Hokuriku area, therefore it is also important to understand the seasonal characteristics of the lightning outages. In summer 70 percent of the lightning outages on distribution lines in Hokuriku area were due to sparkover, such as power wire breakings and failures of pole-mounted transformers. However, in winter almost half of lightning-damaged equipments were surge arrester failures. The number of the lightning outages per lightning strokes detected by the lightning location system (LLS) in winter was 4.4 times larger than that in summer. The authors have presumed the occurrence of lightning outages from lightning stroke density, 50% value of lightning current and installation rate of lightning protection equipments and overhead ground wire by multiple regression analysis. The presumed results suggest the local difference in the lightning outages.

  19. Health monitoring of electric power communication line using a distributed optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Lu, Lidong; Liang, Yun; Li, Binglin; Guo, Jinghong; Zhang, Hao; Zhang, Xuping

    2014-11-01

    Optical fiber ground wire (OPGW) is used for both the earth line and communication line in electric power systems. It is important to find an effective to monitor the status of OPGW and diagnose some possible damages. Fault location of the optical fiber transmission line, lightning stroke location and early-warning of ice covering of OPGW are common tasks for OPGW health monitoring and maintenance. As to these issues, Brillouin optical time domain reflectometry (BOTDR) is employed for the health monitoring of OPGW. In experiment, a positive electrode with high pulsed current and a negative electrode are adopted to form a lightning impulse system with duration time of 200ms for simulation of the lightning stroke process, and a tensile force loading apparatus is also constructed to simulate the strain influence of the ice covering on the OPGW. Experimental results demonstrate that the BOTDR can sensitively locate the lightning stroke incidents with the quantity of electric discharging larger than 100C and the strain component has little interference on temperature monitoring as the fiber contained in the OPGW is generally free of strain, and in the ice covering condition the strain feature appears only when the extra tensile force on the OPGW is over 30kN. In addition, the vibration of OPGW does not disturb both the temperature and strain monitoring. As to further applications of distributed optical fiber sensors (DOFS) for the OPGW health monitoring, it is important to enhance its spatial resolution.

  20. Wire Marking Results in a Small but Significant Reduction in Avian Mortality at Power Lines: A BACI Designed Study

    PubMed Central

    Barrientos, Rafael; Ponce, Carlos; Palacín, Carlos; Martín, Carlos A.; Martín, Beatriz; Alonso, Juan Carlos

    2012-01-01

    Background Collision with electric power lines is a conservation problem for many bird species. Although the implementation of flight diverters is rapidly increasing, few well-designed studies supporting the effectiveness of this costly conservation measure have been published. Methodology/Principal Findings We provide information on the largest worldwide marking experiment to date, including carcass searches at 35 (15 experimental, 20 control) power lines totalling 72.5 km, at both transmission (220 kV) and distribution (15 kV–45 kV) lines. We found carcasses of 45 species, 19 of conservation concern. Numbers of carcasses found were corrected to account for carcass losses due to removal by scavengers or being overlooked by researchers, resulting in an estimated collision rate of 8.2 collisions per km per month. We observed a small (9.6%) but significant decrease in the number of casualties after line marking compared to before line marking in experimental lines. This was not observed in control lines. We found no influence of either marker size (large vs. small spirals, sample of distribution lines only) or power line type (transmission vs. distribution, sample of large spirals only) on the collision rate when we analyzed all species together. However, great bustard mortality was slightly lower when lines were marked with large spirals and in transmission lines after marking. Conclusions Our results confirm the overall effectiveness of wire marking as a way to reduce, but not eliminate, bird collisions with power lines. If raw field data are not corrected by carcass losses due to scavengers and missed observations, findings may be biased. The high cost of this conservation measure suggests a need for more studies to improve its application, including wire marking with non-visual devices. Our findings suggest that different species may respond differently to marking, implying that species-specific patterns should be explored, at least for species of conservation

  1. Computer vision-guided robotic system for electrical power lines maintenance

    NASA Astrophysics Data System (ADS)

    Tremblay, Jack; Laliberte, T.; Houde, Regis; Pelletier, Michel; Gosselin, Clement M.; Laurendeau, Denis

    1995-12-01

    The paper presents several modules of a computer vision assisted robotic system for the maintenance of live electrical power lines. The basic scene of interest is composed of generic components such as a crossarm, a power line and a porcelain insulator. The system is under the supervision of an operator which validates each subtask. The system uses a 3D range finder mounted at the end effector of a 6 dof manipulator for the acquisition of range data on the scene. Since more than one view is required to obtain enough information on the scene, a view integration procedure is applied to the data in order to merge the information in a single reference frame. A volumetric description of the scene, in this case an octree, is built using the range data. The octree is transformed into an occupancy grid which is used for avoiding collisions between the manipulator and the components of the scene during the line manipulation step. The collision avoidance module uses the occupancy grid to create a discrete electrostatic potential field representing the various goals (e.g. objects of interest) and obstacles in the scene. The algorithm takes into account the articular limits of the robot and uses a redundant manipulator to ensure that the collision avoidance constraints do not compete with the task which is to reach a given goal with the end-effector. A pose determination algorithm called Iterative Closest Point is presented. The algorithm allows to compute the pose of the various components of the scene and allows the robot to manipulate these components safely. The system has been tested on an actual scene. The manipulation was successfully implemented using a synchronized geometry range finder mounted on a PUMA 760 robot manipulator under the control of Cartool.

  2. Complexity Analysis of Traffic in Corridors-in-the-Sky

    NASA Technical Reports Server (NTRS)

    Xue, Min; Zelinski, Shannon Jean

    2010-01-01

    The corridors-in-the-sky concept imitates the highway system in ground transportation. The benefit expected from a corridor relies on its capability of handling high density traffic with negligible controller workload, the acceptance of extra fuel or distance, and the complexity reduction in underlying sectors. This work evaluates a selected corridor from these perspectives through simulations. To examine traffic inside the corridor, a corridor traffic simulation tool that can resolve conflicts is developed using C language. Prescribed conflict resolution maneuvers mimic corridor users behaviors and conflict resolution counts measure complexity. Different lane options and operational policies are proposed to examine their impacts on complexity. Fuel consumption is calculated and compared for corridor traffic. On the other hand, to investigate the complexity of non-corridor traffic in underlying sectors, the existing Airspace Concept Evaluation System tool is utilized along with the Automated Airspace Concept tool. The number of conflict resolutions is examined and treated as the complexity measurement. The results show heavy traffic can be managed with low complexity for a historical traffic schedule simulated with appropriate operational policies and lane options. For instance, with 608 flights and peak aircraft count of 100, only 84 actions need to be taken in a 24-hour period to resolve the conflicts for an 8-lane corridor. Compared with the fuel consumptions with great circle trajectories, the simulation of corridor traffic shows that the total extra fuel for corridor flights is 26,373 gallons, or 2.76%, which is 0.38% less than flying filed flight plans. Without taking climb and descent portions of corridor traffic, the complexity of underlying sectors is reduced by 17.71%. However the climb and descent portions will eliminate the reduction and the overall complexity of sectors is actually increased by 9.14%.

  3. Application of offset-CT scanning to the inspection of high power feeder lines and connections

    NASA Astrophysics Data System (ADS)

    Schneberk, Daniel; Maziuk, Robert; Soyfer, Boris; Shashishekhar, N.; Alreja, Rahul

    2016-02-01

    VJT is developing techniques and scanning methods for the in-situ Radiographic and Computed Tomographic inspection of underground high-power feeder cables. The goals for the inspection are to measure the 3D state of the cables and the cable-connections. Recent in-situ Digital Radiographic inspections performed by VJT have demonstrated the value of NDE inspection information for buried power lines. These NDE data have raised further questions as to the exact state of the cables and connections and pointed to the need for more 3D information of the type provided by volumetric CT scanning. VJT is pursuing a three phased approach to address the many issues involved in this type of inspection: 1) develop a high-power feeder-cable test-bed CT scanner, 2) acquire scans on underground feeder pipes that have been removed from service, and 3) from the work in 1) and 2) develop limited-angle CT scanning methods for extending in-situ Digital Radiography to volumetric CT measurements. To this end, VJT has developed and fielded a high-energy test-bed Gantry-type CT scanner (the source and detector move around the object) with a number of important properties. First, the geometry of the gantry-scans can be configured to match the techniques used in the in-situ radiographic inspection. The same X-ray source is employed as in portable Radiographic inspections, a 7.5 MeV Betatron coupled to a Perkin-Elmer Amorphous Silicon detector. Offset-CT scanning is employed as the high-power feeder line assembly is larger than the detector. A description of this scanner and the scan geometry will be presented showing the connection to in-situ radiography. Results from the CT scans of high-power feeder-cable specimens removed from service will be presented with a focus on the inspection potential of volumetric CT data on these assemblies. An evaluation of the scan performance properties of these data compared to the spectrum of life-cycle inspection issues will be presented. Continuing and

  4. Lines

    ERIC Educational Resources Information Center

    Mires, Peter B.

    2006-01-01

    National Geography Standards for the middle school years generally stress the teaching of latitude and longitude. There are many creative ways to explain the great grid that encircles our planet, but the author has found that students in his college-level geography courses especially enjoy human-interest stories associated with lines of latitude…

  5. Novel high-frequency, high-power, pulsed oscillator based on a transmission line transformer.

    PubMed

    Burdt, R; Curry, R D

    2007-07-01

    Recent analysis and experiments have demonstrated the potential for transmission line transformers to be employed as compact, high-frequency, high-power, pulsed oscillators with variable rise time, high output impedance, and high operating efficiency. A prototype system was fabricated and tested that generates a damped sinusoidal wave form at a center frequency of 4 MHz into a 200 Omega load, with operating efficiency above 90% and peak power on the order of 10 MW. The initial rise time of the pulse is variable and two experiments were conducted to demonstrate initial rise times of 12 and 3 ns, corresponding to a spectral content from 4-30 and from 4-100 MHz, respectively. A SPICE model has been developed to accurately predict the circuit behavior and scaling laws have been identified to allow for circuit design at higher frequencies and higher peak power. The applications, circuit analysis, test stand, experimental results, circuit modeling, and design of future systems are all discussed.

  6. 46 CFR 393.3 - Marine Highway Corridors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., landside infrastructure maintenance savings, improved safety, and added system resiliency. Additional... infrastructure maintenance costs, safety and system resiliency. Specify if the Marine Highway Corridor...

  7. 46 CFR 393.3 - Marine Highway Corridors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., landside infrastructure maintenance savings, improved safety, and added system resiliency. Additional... infrastructure maintenance costs, safety and system resiliency. Specify if the Marine Highway Corridor...

  8. 46 CFR 393.3 - Marine Highway Corridors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., landside infrastructure maintenance savings, improved safety, and added system resiliency. Additional... infrastructure maintenance costs, safety and system resiliency. Specify if the Marine Highway Corridor...

  9. 46 CFR 393.3 - Marine Highway Corridors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., landside infrastructure maintenance savings, improved safety, and added system resiliency. Additional... infrastructure maintenance costs, safety and system resiliency. Specify if the Marine Highway Corridor...

  10. WEST CORRIDOR (ORIGINALLY KNOWN AS LIBRARY OF CONGRESS CARD CATALOG) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WEST CORRIDOR (ORIGINALLY KNOWN AS LIBRARY OF CONGRESS CARD CATALOG) ON FIRST FLOOR, LOOKING EAST - Free Library of Philadelphia, Central Library, 1901 Vine Street, Philadelphia, Philadelphia County, PA

  11. Investigation of potential driver modules and transmission lines for a high frequency power system on the space station

    NASA Technical Reports Server (NTRS)

    Brush, Harold T.

    1986-01-01

    The feasibility of using Series Resonant Inverter as the driver module for high frequency power system on the Space Station was assessed. The performance of the Series Resonant Inverter that was used in the testing of the single-phase, 2.0-kw resonant AC power system breadboard is summarized. The architecture is descirbed and the driver modules of the 5.0 kw AC power system breadboard are analyzed. An investigation of the various types of transmission lines is continued. Measurements of equivalent series resistor and inductor and equivalent parallel capacitors are presented. In particular, a simplified approach is utilized to describe the optimal transmission line.

  12. ORNL Trusted Corridors Project: Watts Bar Dam Inland Waterway Project

    SciTech Connect

    Walker, Randy M; Gross, Ian G; Smith, Cyrus M; Hill, David E

    2011-11-01

    Radiation has existed everywhere in the environment since the Earth's formation - in rocks, soil, water, and plants. The mining and processing of naturally occurring radioactive materials for use in medicine, power generation, consumer products, and industry inevitably generate emissions and waste. Radiological measuring devices have been used by industry for years to measure for radiation in undesired locations or simply identify radioactive materials. Since the terrorist attacks on the United States on 9-11-01 these radiation measuring devices have proliferated in many places in our nation's commerce system. DOE, TVA, the Army Corps and ORNL collaborated to test the usefulness of these devices in our nation's waterway system on this project. The purpose of the Watts Bar Dam ORNL Trusted Corridors project was to investigate the security, safety and enforcement needs of local, state and federal government entities for state-of-the-art sensor monitoring in regards to illegal cargo including utilization of the existing infrastructure. TVA's inland waterways lock system is a recognized and accepted infrastructure by the commercial carrier industry. Safety Monitoring activities included tow boat operators, commercial barges and vessels, recreational watercraft and their cargo, identification of unsafe vessels and carriers, and, monitoring of domestic and foreign commercial vessels and cargo identification. Safety Enforcement activities included cargo safety, tracking, identification of hazardous materials, waterway safety regulations, and hazardous materials regulations. Homeland Security and Law Enforcement Applications included Radiological Dispersive Devices (RDD) identification, identification of unsafe or illicit transport of hazardous materials including chemicals and radiological materials, and screening for shipments of illicit drugs. In the Fall of 2005 the SensorNet funding for the project expired. After several unsuccessful attempts to find a Federal sponsor

  13. Environmental Survey Report for the ETTP: Environmental Management Waste Management Facility (EMWMF) Haul Road Corridor, Oak Ridge, Tennessee

    SciTech Connect

    Peterson, M.J.

    2005-12-20

    This report summarizes the results of environmental surveys conducted within the corridor of a temporary haul road (''Haul Road'') to be constructed from East Tennessee Technology Park (ETTP) to the Environmental Management Waste Management Facility (EMWMF) located just west of the Y-12 National Security Complex (Y-12). Environmental surveys were conducted by natural resource experts at Oak Ridge National Laboratory who routinely assess the significance of various project activities on the Oak Ridge Reservation (ORR). ORNL assistance to the Haul Road Project included environmental assessments necessary to determine the best route for minimizing impacts to sensitive resources such as wetlands or rare plants. Once the final route was chosen, environmental surveys were conducted within the corridor to evaluate the impacts to sensitive resources that could not be avoided. The final Haul Road route follows established roads and a power-line corridor to the extent possible (Fig. 1). Detailed explanation regarding the purpose of the Haul Road and the regulatory context associated with its construction is provided in at least two major documents and consequently is not presented here: (1) Explanation of Significant Differences for the Record of Decision for the Disposal of Oak Ridge Reservation Comprehensive Environmental Response, Compensation, and Liability Act of 1980 Waste, Oak Ridge, Tennessee (January 2005, DOE/OR/01-2194&D2), and (2) Environmental Monitoring Plan for The ETTP to EMWMF Haul Road for the Disposal of Oak Ridge Reservation Comprehensive Environmental Response, Compensation, and Liability Act of 1980 Waste, Oak Ridge, Tennessee (April 2005, BJC/OR-2152). The focus of this report is a description of the sensitive resources to be impacted by Haul Road construction. Following a short description of the methods used for the environmental surveys, results and observations are presented in the following subsections: (1) General description of the affected

  14. Unsupervised learning technique for surface electromyogram denoising from power line interference and baseline wander.

    PubMed

    Niegowski, Maciej; Zivanovic, Miroslav; Gomez, Marisol; Lecumberri, Pablo

    2015-01-01

    We present a novel approach to single-channel power line interference (PLI) and baseline wander (BW) removal from surface electromyograms (EMG). It is based on non-negative matrix factorization (NMF) using a priori knowledge about the interferences. It performs a linear decomposition of the input signal spectrogram into non-negative components, which represent the PLI, BW and EMG spectrogram estimates. They all exhibit very different time-frequency patterns: PLI and BW are both sparse whereas EMG is noise-like. Initialization of the classical NMF algorithm with accurately designed PLI, BW and EMG structures and a carefully adjusted matrix decomposition rank increases the separation performance. The comparative study suggests that the proposed method outperforms two state-of-the-art reference methods.

  15. Spectral response of atmospheric electric field measurements near AC high voltage power lines

    NASA Astrophysics Data System (ADS)

    Silva, H. G.; Matthews, J. C.; Wright, M. D.; Shallcross, D. E.

    2015-10-01

    To understand the influence of corona ion emission on the atmospheric electrical field, measurements were made near to two AC high voltage power lines. A JCI 131 field-mill recorded the atmospheric electric field over one year. Meteorological measurements were also taken. The data series is divided in four zones (dependent on wind direction): whole zones, Z0; zone 1, Z1; zone 2, Z2; zone 3, Z3. Z3 is the least affected by corona ion emission and for that reason it is used as a reference against Z1 and Z2, which are strongly influenced by this phenomena. Analysis was undertaken for all weather days and dry days only. The Lomb-Scargle strategy developed for unevenly spaced time-series is used to calculate the spectral response of the aforementioned zones. Only frequencies above 1 minute are considered.

  16. Measurements of induced voltages and currents in a distribution power line and associated atmospheric parameters

    NASA Technical Reports Server (NTRS)

    Santiago-Perez, Julio

    1988-01-01

    The frequency and intensity of thunderstorms around the Kennedy Space Center (KSC) has affected scheduled launch, landing, and other ground operations for many years. In order to protect against and provide safe working facilities, KSC has performed and hosted several studies on lightning phenomena. For the reasons mentioned above, KSC has established the Atmospheric Science Field Laboratory (ASFL). At these facilities KSC launches wire-towing rockets into thunderstorms to trigger natural lightning to the launch site. A program named Rocket Triggered Lightning Program (RTLP) is being conducted at the ASFL. This report calls for two of the experiments conducted in the summer 1988 Rocket Triggered Lightning Program. One experiment suspended an electric field mill over the launching areas from a balloon about 500 meters high to measure the space charges over the launching area. The other was to connect a waveform recorder to a nearby distribution power line to record currents and voltages wave forms induced by natural and triggered lightning.

  17. Ergonomics hazards analysis of linemen's power line fixing work in China.

    PubMed

    Yu, Ming; Sun, Linyan; Du, Jianhua; Wu, Fengge

    2009-01-01

    This study used qualitative and quantitative methods, such as OWAS (Ovako working posture analysis system) and behavior observation, to analyze musculoskeletal disorder (MSD) risk factors of power line fixing work in China. Video-based sampling was used to record and analyze the frequency and posture of on-pole activities. Those key subtasks showed ergonomics characteristics of on-pole fixing tasks. Insulator-fixing was the longest subtask (33% of total working time). Bar-installing was the second longest (26% of total working time). It was evident that bar-installing and insulator-fixing were full of hazardous risks. The action categories of the 2 subtasks were higher than of the other ones. The 2 subtasks were also time-consuming, difficult and induced MSDs. Assistant linemen faced more hazardous factors than chief linemen.

  18. Buccal Corridors: A Fact or a Myth in the Eyes of Laymen?

    PubMed Central

    Elhiny, Omnia A.; Harhash, Asmaa Y.

    2016-01-01

    AIM: This study aimed to investigate laymen knowledge of the existence of the buccal corridor and whether it was an important factor for them in judging smile attractiveness and the effect of introducing the knowledge to them on their further judgment. MATERIALS AND METHODS: Nine subjects were randomly selected with variable buccal corridor percentages. They were coached to smile in a posed fashion and full face smile photographs were taken from a standardised distance. The photographs were randomly arranged in a power point presentation and displayed to a panel of thirty-nine randomly selected laymen judges. The judges made their beauty judgment on a visual analogue scale (VAS) and filled a questionnaire. After their education about the buccal corridor, they were asked to make a second judgment on a second sheet with VAS and with a different random sequence of the photographs. RESULTS: Intra-class correlation agreement for all the judges between the first and second scores was 0.713. The Spearman’s rho Correlation coefficient indicated a positive correlation for all the photos. For the male judges, the agreement between the ratings was 0.839, and the correlation was positive for all the photos. For the female judges, the agreement between the ratings was 0.510, and the correlation was positive for all the photographs. Hundred percent of the judges were not familiar with the buccal corridor. Eighty percent of the female judges and 44.4% of the male judges mentioned that it would affect their further judgment. CONCLUSION: Laymen build their esthetic judgments on what we teach them, and modifying treatment plans to include corrections of buccal corridors for esthetic reasons only is a myth. PMID:28028418

  19. Tucson Electric Power Company Sahuarita-Nogales Transmission Line Draft Environmental Impact Statement

    SciTech Connect

    N /A

    2003-08-27

    Tucson Electric Power Company (TEP) has applied to the U.S. Department of Energy (DOE) for a Presidential Permit to construct and operate a double-circuit, 345,000-volt (345-kV) electric transmission line across the United States border with Mexico. Under Executive Order (EO) 10485 of September 3, 1953, as amended by EO 12038 of February 3, 1978, a Presidential Permit is required to construct, connect, operate, or maintain facilities at the U.S. international border for the transmission of electric energy between the United States and a foreign country. DOE has determined that the issuance of a Presidential Permit to TEP for the proposed project would constitute a major Federal action that may have a significant impact on the environment within the meaning of the ''National Environmental Policy Act of 1969'' (NEPA) 42 United States Code (U.S.C.) {section}4321 et seq. For this reason, DOE has prepared this Draft Environmental Impact Statement (EIS) to evaluate potential environmental impacts from the proposed Federal action (granting a Presidential Permit for the proposed transmission facilities) and reasonable alternatives, including the No Action Alternative. This EIS was prepared in accordance with Section 102(2)(c) of NEPA, Council of Environmental Quality (CEQ) regulations (40 Code of Federal Regulations [CFR] 1500-1508), and DOE NEPA Implementing Procedures (10 CFR 1021). DOE is the lead Federal Agency, as defined by 40 CFR 1501.5. The U.S. Department of Agriculture Forest Service (USFS), the Bureau of Land Management (BLM) of the U.S. Department of the Interior, and the U.S. Section of the International Boundary and Water Commission, U.S. and Mexico (USIBWC), are cooperating agencies. Each of these organizations will use the EIS for its own NEPA purposes, as described in the Federal Agencies' Purpose and Need and Authorizing Actions section of this summary. The 345-kV double-circuit transmission line would consist of twelve transmission line wires, or

  20. Harmonic resonance on parallel high voltage transmission lines

    SciTech Connect

    Harries, J.R.; Randall, J.L.

    1997-01-01

    The Bonneville Power Administration (BPA) has received complaints of telephone interference over a wide area of northwestern Washington State for several years. However, until 1995 investigations had proved inconclusive as either the source of the harmonics or the operating conditions changed whenever investigators arrived. The 2,100 Hz interference had been noticed at several optically isolated telephone exchanges. The area of complaint corresponded to electric service areas near the transmission line corridors of the BPA Custer-Monroe 500-kV lines. High 2,100 Hz field strength was measured near the 500-kV lines and also under lower voltage lines served from stations along the transmission line corridor. Tests and studies made with the Alternative Transients Program version of the Electromagnetic Transients Program (EMTP) were able to define the phenomena and isolate the source. Harmonic resonance has been observed, measured and modeled on parallel 500-kV lines that are about one wavelength at 2,100 Hz, the 35th harmonic. A seemingly small harmonic injection at one location on the system causes significant problems some distance away such as telephone interference.

  1. On-line mechanical tube cleaning for steam electric power plants. Final report

    SciTech Connect

    Not Available

    1994-02-18

    In July 1991, Superior I.D. Tube Cleaners, Inc. (SIDTEC{trademark}) received a grant through the Department of Energy and the Energy Related Invention Program to conduct a long term demonstration of a proprietary technology for on-line mechanical condenser tube cleaning in thermal Power plants on open or once-through cooling water systems where the warmed condenser cooling water is discharged through a canal. The purpose of the demonstration was to confirm and establish the use of this mechanical method as an alternative to the application of chemical biocides in condenser cooling water for the control of biofouling, the growth of micro-organisms which can reduce a unit`s operating efficiency. The SIDTEC on-line mechanical tube cleaner, the Rocket{trademark}, is used to physically remove accumulated deposits on the water side of the main steam condenser, and the non-intrusive tube cleaner recovery system, the Skimmer{trademark}, is used to recover and recirculate tube cleaners. The periodic circulation of tube cleaners can maintain optimum condenser cleanliness and improve unit heat rate. Thermal power plants which discharge condenser cooling water through a canal now have a viable alternative to the chemical treatment of condenser cooling water, whether the principal foulant is biofouling, chemical scaling, silting, or a combination of the three. At prices competitive with scale inhibitors, and a fraction of competing mechanical systems, this technology is provided as a service requiring no capital investment; minimal retrofit modifications to plant structures or equipment; can be installed and maintained without a unit shutdown; does not add any restrictions in the cooling water system; and is environmentally benign.

  2. Imprint of DESI fiber assignment on the anisotropic power spectrum of emission line galaxies

    NASA Astrophysics Data System (ADS)

    Pinol, Lucas; Cahn, Robert N.; Hand, Nick; Seljak, Uroš; White, Martin

    2017-04-01

    The Dark Energy Spectroscopic Instrument (DESI), a multiplexed fiber-fed spectrograph, is a Stage-IV ground-based dark energy experiment aiming to measure redshifts for 29 million Emission-Line Galaxies (ELG), 4 million Luminous Red Galaxies (LRG), and 2 million Quasi-Stellar Objects (QSO). The survey design includes a pattern of tiling on the sky, the locations of the fiber positioners in the focal plane of the telescope, and an observation strategy determined by a fiber assignment algorithm that optimizes the allocation of fibers to targets. This strategy allows a given region to be covered on average five times for a five-year survey, with a typical variation of about 1.5 about the mean, which imprints a spatially-dependent pattern on the galaxy clustering. We investigate the systematic effects of the fiber assignment coverage on the anisotropic galaxy clustering of ELGs and show that, in the absence of any corrections, it leads to discrepancies of order ten percent on large scales for the power spectrum multipoles. We introduce a method where objects in a random catalog are assigned a coverage, and the mean density is separately computed for each coverage factor. We show that this method reduces, but does not eliminate the effect. We next investigate the angular dependence of the contaminated signal, arguing that it is mostly localized to purely transverse modes. We demonstrate that the cleanest way to remove the contaminating signal is to perform an analysis of the anisotropic power spectrum P(k,μ) and remove the lowest μ bin, leaving μ > 0 modes accurate at the few-percent level. Here, μ is the cosine of the angle between the line-of-sight and the direction of vec k. We also investigate two alternative definitions of the random catalog and show that they are comparable but less effective than the coverage randoms method.

  3. Population dynamics of Microtus pennsylvanicus in corridor-linked patches

    USGS Publications Warehouse

    Coffman, C.J.; Nichols, J.D.; Pollock, K.H.

    2001-01-01

    Corridors have become a key issue in the discussion of conservation planning: however, few empirical data exist on the use of corridors and their effects on population dynamics. The objective of this replicated, population level, capture-re-capture experiment on meadow voles was to estimate and compare population characteristics of voles between (1) corridor-linked fragments, (2) isolated or non-linked fragments, and (3) unfragmented areas. We conducted two field experiments involving 22600 captures of 5700 individuals. In the first, the maintained corridor study, corridors were maintained at the time of fragmentation, and in the second, the constructed corridor study, we constructed corridors between patches that had been fragmented for some period of time. We applied multistate capture-recapture models with the robust design to estimate adult movement and survival rates, population size, temporal variation in population size, recruitment, and juvenile survival rates. Movement rates increased to a greater extent on constructed corridor-linked grids than on the unfragmented or non-linked fragmented grids between the pre- and post-treatment periods. We found significant differences in local survival on the treated (corridor-linked) grids compared to survival on the fragmented and unfragmented grids between the pre- and post-treatment periods. We found no clear pattern of treatment effects on population size or recruitment in either study. However, in both studies, we found that unfragmented grids were more stable than the fragmented grids based on lower temporal variability in population size. To our knowledge, this is the first experimental study demonstrating that corridors constructed between existing fragmented populations can indeed cause increases in movement and associated changes in demography, supporting the use of constructed corridors for this purpose in conservation biology.

  4. Evaluating landscape options for corridor restoration between giant panda reserves.

    PubMed

    Wang, Fang; McShea, William J; Wang, Dajun; Li, Sheng; Zhao, Qing; Wang, Hao; Lu, Zhi

    2014-01-01

    The establishment of corridors can offset the negative effects of habitat fragmentation by connecting isolated habitat patches. However, the practical value of corridor planning is minimal if corridor identification is not based on reliable quantitative information about species-environment relationships. An example of this need for quantitative information is planning for giant panda conservation. Although the species has been the focus of intense conservation efforts for decades, most corridor projects remain hypothetical due to the lack of reliable quantitative researches at an appropriate spatial scale. In this paper, we evaluated a framework for giant panda forest corridor planning. We linked our field survey data with satellite imagery, and conducted species occupancy modelling to examine the habitat use of giant panda within the potential corridor area. We then conducted least-cost and circuit models to identify potential paths of dispersal across the landscape, and compared the predicted cost under current conditions and alternative conservation management options considered during corridor planning. We found that due to giant panda's association with areas of low elevation and flat terrain, human infrastructures in the same area have resulted in corridor fragmentation. We then identified areas with high potential to function as movement corridors, and our analysis of alternative conservation scenarios showed that both forest/bamboo restoration and automobile tunnel construction would significantly improve the effectiveness of corridor, while residence relocation would not significantly improve corridor effectiveness in comparison with the current condition. The framework has general value in any conservation activities that anticipate improving habitat connectivity in human modified landscapes. Specifically, our study suggested that, in this landscape, automobile tunnels are the best means to remove current barriers to giant panda movements caused by

  5. Overhead electric power transmission line jumpering system for bundles of five or more subconductors

    DOEpatents

    Winkelman, Paul F.

    1982-01-01

    Jumpering of electric power transmission lines at a dead end tower. Two transmission line conductor bundles each contain five or more spaced apart subconductors (5) arranged in the shape of a cylinder having a circular cross section. The ends of each bundle of subconductors are attached with insulators to a dead end tower (1). Jumpering allows the electric current to flow between the two bundles of subconductors using jumper buses, internal jumper conductors, and external jumper conductors. One or more current collecting jumper buses (37) are located inside each bundle of subconductors with each jumper bus being attached to the end of a subconductor. Small-diameter internal jumper conductors (33) are located in the inherently electrically shielded area inside each bundle of subconductors with each subconductor (except ones having an attached jumper bus) having one internal jumper conductor connected between that subconductor's end and a jumper bus. Large-diameter external jumper conductors (9) are located outside each bundle of subconductors with one or more external jumper conductors being connected between the jumper buses in one bundle of subconductors and the jumper buses in the other bundle.

  6. Air ion mobility spectra and concentrations upwind and downwind of overhead AC high voltage power lines

    NASA Astrophysics Data System (ADS)

    Wright, Matthew D.; Buckley, Alison J.; Matthews, James C.; Shallcross, Dudley E.; Henshaw, Denis L.

    2014-10-01

    Corona ions produced by high-voltage power lines (HVPLs) can alter the nearby electrical environment, potentially increasing aerosol charge levels downwind. However, there is a lack of knowledge concerning the concentration and mobility of ions from AC HVPLs and their dispersion away from the line. We present ion concentration and mobility measurements made near AC HVPLs in South-West England. Examples of typical mobility spectra are shown highlighting features commonly observed. Corona was observed during 33 of 46 measurements, at 9 of 11 sites, with positive or ‘bipolar' (both polarities) ion production commonly seen. Ion production usually increases atmospheric concentrations by only a modest amount, but extreme cases can enhance concentration by an order of magnitude or more. A polarity imbalance is required to increase aerosol charge via ion attachment; this was observed on 15 of 24 days when positive corona was observed, but was not seen for negative ions. Ion mobility was higher downwind compared with upwind for both ion polarities, but the increase was not statistically significant. Future work should focus on identifying and characterising ‘heavy-producing' HVPLs, and obtaining results in conditions which may favour negative ion production e.g. high humidity, inclement weather or during nighttime.

  7. Line-Focus Solar Power Plant Cost Reduction Plan (Milestone Report)

    SciTech Connect

    Kutscher, C.; Mehos, M.; Turchi, C.; Glatzmaier, G.; Moss, T.

    2010-12-01

    Line-focus solar collectors, in particular parabolic trough collectors, are the most mature and proven technology available for producing central electricity from concentrated solar energy. Because this technology has over 25 years of successful operational experience, resulting in a low perceived risk, it is likely that it will continue to be a favorite of investors for some time. The concentrating solar power (CSP) industry is developing parabolic trough projects that will cost billions of dollars, and it is supporting these projects with hundreds of millions of dollars of research and development funding. While this technology offers many advantages over conventional electricity generation -- such as utilizing plentiful domestic renewable fuel and having very low emissions of greenhouse gases and air pollutants -- it provides electricity in the intermediate power market at about twice the cost of its conventional competitor, combined cycle natural gas. The purpose of this document is to define a set of activities from fiscal year 2011 to fiscal year 2016 that will make this technology economically competitive with conventional means.

  8. Implementation of an on-line monitoring system for transmitters in a CANDU nuclear power plant

    NASA Astrophysics Data System (ADS)

    Labbe, A.; Abdul-Nour, G.; Vaillancourt, R.; Komljenovic, D.

    2012-05-01

    Many transmitters (pressure, level and flow) are used in a nuclear power plant. It is necessary to calibrate them periodically to ensure that their measurements are accurate. These calibration tasks are time consuming and often contribute to worker radiation exposure. Human errors can also sometimes degrade their performance since the calibration involves intrusive techniques. More importantly, experience has shown that the majority of current calibration efforts are not necessary. These facts motivated the nuclear industry to develop new technologies for identifying drifting instruments. These technologies, well known as on-line monitoring (OLM) techniques, are non-intrusive and allow focusing the maintenance efforts on the instruments that really need a calibration. Although few OLM systems have been implemented in some PWR and BWR plants, these technologies are not commonly used and have not been permanently implemented in a CANDU plant. This paper presents the results of a research project that has been performed in a CANDU plant in order to validate the implementation of an OLM system. An application project, based on the ICMP algorithm developed by EPRI, has been carried out in order to evaluate the performance of an OLM system. The results demonstrated that the OLM system was able to detect the drift of an instrument in the majority of the studied cases. A feasibility study has also been completed and has demonstrated that the implementation of an OLM system at a CANDU nuclear power plant could be advantageous under certain conditions.

  9. NIOSH alert: Request for assistance in preventing electrocutions of crane operators and crew members working near overhead power lines

    SciTech Connect

    1995-05-01

    In this alert, NIOSH warned that crane operators and crew members may be electrocuted when working near overhead power lines. Five cases were described which resulted in six electrocutions. Case 1 involved a 29 year old who pushed the crane cable on a 1 yard cement bucket into a 7,200 volt power line. Case 2 involved a 33 year old well driller who was electrocuted when a metal pipe lifted by a truck mounted crane contacted a 12,000 volt overhead power line. The third case involved a 24 year old forman for a telecommunications company who was electrocuted when he grabbed the door handle of a truck mounted crane whose boom was in contact with a 7,200 volt overhead power line. Case 4 involved a 37 year old construction laborer electrocuted while pulling a wire rope attached to a crane cable toward a load. The fifth case involved a 20 year old male truck driver and his 70 year old male employer who were electrocuted when the boom of a truck mounted crane contacted a 7,200 volt conductor of an overhead power line.

  10. Self-tuning wireless power transmission scheme based on on-line scattering parameters measurement and two-side power matching.

    PubMed

    Luo, Yanting; Yang, Yongmin; Chen, Zhongsheng

    2014-04-10

    Sub-resonances often happen in wireless power transmission (WPT) systems using coupled magnetic resonances (CMR) due to environmental changes, coil movements or component degradations, which is a serious challenge for high efficiency power transmission. Thus self-tuning is very significant to keep WPT systems following strongly magnetic resonant conditions in practice. Traditional coupled-mode ways is difficult to solve this problem. In this paper a two-port power wave model is presented, where power matching and the overall systemic power transmission efficiency are firstly defined by scattering (S) parameters. Then we propose a novel self-tuning scheme based on on-line S parameters measurements and two-side power matching. Experimental results testify the feasibility of the proposed method. These findings suggest that the proposed method is much potential to develop strongly self-adaptive WPT systems with CMR.

  11. Solving the 56Ni Puzzle of Magnetar-powered Broad-lined Type IC Supernovae

    NASA Astrophysics Data System (ADS)

    Wang, Ling-Jun; Han, Yan-Hui; Xu, Dong; Wang, Shan-Qin; Dai, Zi-Gao; Wu, Xue-Feng; Wei, Jian-Yan

    2016-11-01

    Broad-lined Type Ic supernovae (SNe Ic-BL) are of great importance because their association with long-duration gamma-ray bursts (LGRBs) holds the key to deciphering the central engine of LGRBs, which refrains from being unveiled despite decades of investigation. Among the two popularly hypothesized types of central engine, i.e., black holes and strongly magnetized neutron stars (magnetars), there is mounting evidence that the central engine of GRB-associated SNe (GRB-SNe) is rapidly rotating magnetars. Theoretical analysis also suggests that magnetars could be the central engine of SNe Ic-BL. What puzzled the researchers is the fact that light-curve modeling indicates that as much as 0.2{--}0.5 {M}⊙ of 56Ni was synthesized during the explosion of the SNe Ic-BL, which is unfortunately in direct conflict with current state-of-the-art understanding of magnetar-powered 56Ni synthesis. Here we propose a dynamic model of magnetar-powered SNe to take into account the acceleration of the ejecta by the magnetar, as well as the thermalization of the injected energy. Assuming that the SN kinetic energy comes exclusively from the magnetar acceleration, we find that although a major fraction of the rotational energy of the magnetar is to accelerate the SN ejecta, a tiny fraction of this energy deposited as thermal energy of the ejecta is enough to reduce the needed 56Ni to 0.06 M ⊙ for both SN 1997ef and SN 2007ru. We therefore suggest that magnetars could power SNe Ic-BL in aspects both of energetics and of 56Ni synthesis.

  12. A novel modular approach to active power-line harmonic filtering in distribution systems

    NASA Astrophysics Data System (ADS)

    El Shatshat, Ramadan A.

    The objective of this research is to develop an efficient and reliable modular active harmonic filter system to realize a cost-effective solution to the harmonic problem. The proposed filter system consists of a number CSC modules, each dedicated to filter a specific harmonic of choice (Frequency-Splitting Approach). The power rating of the modules will decrease and their switching frequency will increase as the order of the harmonic to be filtered is increased. The overall switching losses are minimized due to the selected harmonic elimination and balanced a "power rating"-"switching frequency" product. Two ADALINEs are proposed as a part of the filter controller for processing the signals obtained from the power-line. One ADALINE (the Current ADALINE) extracts the fundamental and harmonic components of the distorted current. The other ADALINE (the Voltage ADALINE) estimates the line voltage. The outputs of both ADALINEs are used to construct the modulating signals of the filter modules. The proposed controller decides which CSC filter module(s) is connected to the electric grid. The automated connection of the corresponding filter module(s) is based on decision-making rules in such a way that the IEEE 519-1992 limits are not violated. The information available on the magnitude of each harmonic component allows us to select the active filter bandwidth (i.e., the highest harmonic to be suppressed). This will result in more efficiency and higher performance. The proposed controller adjusts the I dc in each CSC module according to the present magnitude of the corresponding harmonic current. This results in optimum dc-side current value and minimal converter losses. The comparison of the proposed modular active filter scheme and the conventional one converter scheme on practical use in industry is presented. This comparison shows that the proposed solution is more economical, reliable and flexible compared to conventional one. High speed and accuracy of ADALINE, self

  13. 46 CFR 108.161 - Dead end corridors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Dead end corridors. 108.161 Section 108.161 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Means of Escape § 108.161 Dead end corridors. No dead end...

  14. 46 CFR 108.161 - Dead end corridors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Dead end corridors. 108.161 Section 108.161 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Means of Escape § 108.161 Dead end corridors. No dead end...

  15. 46 CFR 108.161 - Dead end corridors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Dead end corridors. 108.161 Section 108.161 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Means of Escape § 108.161 Dead end corridors. No dead end...

  16. A corridor on the first floor of the building, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    A corridor on the first floor of the building, looking west, shows some of the typical interior finishes in this section. At the end of the hallway, the corridor turns right after entering the next adjacent structure - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  17. Can dispersal mode predict corridor effects on plant parasites?

    SciTech Connect

    Sullivan, Lauren, L.; Johnson, Brenda, L.; Brudvig, Lars, A.; Haddad, Nick, M.

    2011-08-01

    Habitat corridors, a common management strategy for increasing connectivity in fragmented landscapes, have experimentally validated positive influences on species movement and diversity. However, long-standing concerns that corridors could negatively impact native species by spreading antagonists, such as disease, remain largely untested. Using a large-scale, replicated experiment, we evaluated whether corridors increase the incidence of plant parasites. We found that corridor impacts varied with parasite dispersal mode. Connectivity provided by corridors increased incidence of biotically dispersed parasites (galls on Solidago odora) but not of abiotically dispersed parasites (foliar fungi on S. odora and three Lespedeza spp.). Both biotically and abiotically dispersed parasites responded to edge effects, but the direction of responses varied across species. Although our results require additional tests for generality to other species and landscapes, they suggest that, when establishing conservation corridors, managers should focus on mitigating two potential negative effects: the indirect effects of narrow corridors in creating edges and direct effects of corridors in enhancing connectivity of biotically dispersed parasites.

  18. 43 CFR 2802.11 - How does BLM designate corridors?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... which lands may be suitable for right-of-way corridors, the factors BLM considers include, but are not..., local, and tribal laws; (2) Environmental impacts on cultural resources and natural resources, including... activities located within the proposed right-of-way corridor; (7) Social and economic impacts of the...

  19. 43 CFR 2802.11 - How does BLM designate corridors?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... which lands may be suitable for right-of-way corridors, the factors BLM considers include, but are not..., local, and tribal laws; (2) Environmental impacts on cultural resources and natural resources, including... activities located within the proposed right-of-way corridor; (7) Social and economic impacts of the...

  20. 43 CFR 2802.11 - How does BLM designate corridors?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... which lands may be suitable for right-of-way corridors, the factors BLM considers include, but are not..., local, and tribal laws; (2) Environmental impacts on cultural resources and natural resources, including... activities located within the proposed right-of-way corridor; (7) Social and economic impacts of the...

  1. 43 CFR 2802.11 - How does BLM designate corridors?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... which lands may be suitable for right-of-way corridors, the factors BLM considers include, but are not..., local, and tribal laws; (2) Environmental impacts on cultural resources and natural resources, including... activities located within the proposed right-of-way corridor; (7) Social and economic impacts of the...

  2. 46 CFR 108.161 - Dead end corridors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dead end corridors. 108.161 Section 108.161 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Means of Escape § 108.161 Dead end corridors. No dead end...

  3. Courtyard. Left wall is corridor from 511 to 515. Right ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Courtyard. Left wall is corridor from 511 to 515. Right wall is the south side of 517. - Fitzsimons General Hospital, Physiotherapy & Electrocardiograph Department Building, North of Building No. 516, East of corridor connecting Building No. 511 to Building No. 515, Aurora, Adams County, CO

  4. 46 CFR 108.161 - Dead end corridors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Dead end corridors. 108.161 Section 108.161 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Means of Escape § 108.161 Dead end corridors. No dead end...

  5. Staff corridor (room 206, representing rooms 301, 305, 401, 405, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Staff corridor (room 206, representing rooms 301, 305, 401, 405, 501, and 505), looking south towards the staff corridor vestibule (room 206A, representing rooms 305A, 405A, and 505A). - California State Office Building No. 1, 915 Capitol Mall, Sacramento, Sacramento County, CA

  6. An experimental test of whether habitat corridors affect pollen transfer.

    SciTech Connect

    Townsend, Patricia A.; Levey, Douglas J.

    2005-02-01

    Abstract. Negative effects of habitat fragmentation are thought to be diminished when habitat patches are joined by a corridor. A key assumption is that corridors facilitate exchange rates of organisms between otherwise isolated patches. If the organisms are pollinators, corridors may be important for maintaining genetically viable populations of the plants that they pollinate. We tested the hypothesis that corridors increase the movement of insect pollinators into patches of habitat and thereby increase pollen transfer for two species of plants, one pollinated by butterflies (Lantana camara) and the other by bees and wasps (Rudbeckia hirta). We worked in an experimental landscape consisting of 40 greater than or equal to 1-ha patches of early-successional habitat in a matrix of forest. Within each of eight experimental units, two patches were connected by a corridor (150 X 25 m), and three were not. Patch shape varied to control for the area added by the presence of a corridor. Differences in patch shape also allowed us to test alternative hypotheses of how corridors might function. The Traditional Corridor Hypothesis posits that corridors increase immigration and emigration by functioning as movement conduits between patches. The Drift Fence Hypothesis posits that corridors function by ‘‘capturing’’ organisms dispersing through the matrix, redirecting them into associated habitat patches. Using fluorescent powder to track pollen, we found that pollen transfer by butterflies between patches connected by a corridor was significantly higher than between unconnected patches (all values mean plus or minus 1 SE: 59% plus or minus 9.2% vs. 25% plus or minus 5.2% of flowers receiving pollen). Likewise, pollen transfer by bees and wasps was significantly higher between connected patches than between unconnected patches (30% plus or minus 4.2% vs. 14.5% plus or minus 2.2%). These results support the Traditional Corridor Hypothesis. There was little support, however

  7. The Power Behind the Controversy: Understanding Local Policy Elites' Perceptions on the Benefits and Risks Associated with High Voltage Power Line Installation in the State of Arkansas

    NASA Astrophysics Data System (ADS)

    Moyer, Rachael M.

    Following a proposal for the installation of high voltage power lines in northwest Arkansas, a controversial policy debate emerged. Proponents of the transmission line argue that such an installation is inevitable and necessary to efficiently and reliably support the identified electric load in the region. Opponents claim that the lines will degrade the natural environment and hamper the tourism-based local economy in affected regions, notably in Ozark Mountain areas. This study seeks to understand how local policy elites perceive the benefits and risks associated with proposed transmission lines, which is a critical step in comprehending the formation and changes of related government policies. First, based upon the dual process theory of judgment, this study systematically investigates the triadic relationships between (a) more profound personal value predispositions, (b) affects and feelings, and (c) perceived benefits and risks related to the proposed installation of high voltage power lines among local policy elites in the state of Arkansas. Next, this study focuses more specifically on the role of value predispositions, specific emotional dimensions of affect heuristics, and perceptions pertaining to high voltage power line risks and benefits. Using original data collected from a statewide Internet survey of 420 local leaders and key policymakers about their opinions on the related issues, other factors claimed by previous literature, including trust, knowledge level, and demographic characteristics are considered. Analytical results suggest that grid-group cultural predispositions, as deeply held core values within local policy elites' individual belief systems, both directly and indirectly -- through affective feelings -- shape perceived utility associated with the installation of high voltage power lines. Recognizing that risk perceptions factor into policy decisions, some practical considerations for better designing policy addressing controversial issues

  8. Relative accuracy of grid references derived from postcode and address in UK epidemiological studies of overhead power lines.

    PubMed

    Swanson, J; Vincent, T J; Bunch, K J

    2014-12-01

    In the UK, the location of an address, necessary for calculating the distance to overhead power lines in epidemiological studies, is available from different sources. We assess the accuracy of each. The grid reference specific to each address, provided by the Ordnance Survey product Address-Point, is generally accurate to a few metres, which will usually be sufficient for calculating magnetic fields from the power lines. The grid reference derived from the postcode rather than the individual address is generally accurate to tens of metres, and may be acceptable for assessing effects that vary in the general proximity of the power line, but is probably not acceptable for assessing magnetic-field effects.

  9. Geometric Context and Orientation Map Combination for Indoor Corridor Modeling Using a Single Image

    NASA Astrophysics Data System (ADS)

    Baligh Jahromi, Ali; Sohn, Gunho

    2016-06-01

    Since people spend most of their time indoors, their indoor activities and related issues in health, security and energy consumption have to be understood. Hence, gathering and representing spatial information of indoor spaces in form of 3D models become very important. Considering the available data gathering techniques with respect to the sensors cost and data processing time, single images proved to be one of the reliable sources. Many of the current single image based indoor space modeling methods are defining the scene as a single box primitive. This domain-specific knowledge is usually not applicable in various cases where multiple corridors are joined at one scene. Here, we addressed this issue by hypothesizing-verifying multiple box primitives which represents the indoor corridor layout. Middle-level perceptual organization is the foundation of the proposed method, which relies on finding corridor layout boundaries using both detected line segments and virtual rays created by orthogonal vanishing points. Due to the presence of objects, shadows and occlusions, a comprehensive interpretation of the edge relations is often concealed. This necessitates the utilization of virtual rays to create a physically valid layout hypothesis. Many of the former methods used Orientation Map or Geometric Context to evaluate their proposed layout hypotheses. Orientation map is a map that reveals the local belief of region orientations computed from line segments, and in a segmented image geometric context uses color, texture, edge, and vanishing point cues to estimate the likelihood of each possible label for all super-pixels. Here, the created layout hypotheses are evaluated by an objective function which considers the fusion of orientation map and geometric context with respect to the horizontal viewing angle at each image pixel. Finally, the best indoor corridor layout hypothesis which gets the highest score from the scoring function will be selected and converted to a 3D

  10. Adaptive settings of distance relay for MOV-protected series compensated line with distributed capacitance considering wind power

    NASA Astrophysics Data System (ADS)

    Sivov, Oleg Viktorovich

    Series compensated lines are protected from overvoltage by metal-oxide-varistors (MOVs) connected in parallel with the capacitor bank. The nonlinear characteristics of MOV devices add complexity to fault analysis and distance protection operation. During faults, the impedance of the line is modified by an equivalent impedance of the parallel MOV/capacitor circuit, which affects the distance protection. The intermittent wind generation introduces additional complexity to the system performance and distance protection. Wind variation affects the fault current level and equivalent MOV/capacitor impedance during a fault, and hence the distance relay operation. This thesis studies the impact of the intermittent wind power generation on the operation of MOV during faults. For the purpose of simulation, an equivalent wind farm model is proposed to generate a wind generation profile using wind farm generation from California independent system operator (ISO) as a guide for wind power variation to perform the study. The IEEE 12-bus test system is modified to include MOV-protected series capacitor and the equivalent wind farm model. The modified test system is simulated in the MATLAB/Simulink environment. The study has been achieved considering three phase and single line to ground (SLG) faults on the series compensated line to show the effect of wind variation on the MOV operation. This thesis proposes an adaptive setting method for the mho relay distance protection of series compensated line considering effects of wind power variation and MOV operation. The distributed parameters of a transmission line are taken into account to avoid overreaching and underreaching of distance relays. The study shows that variable wind power affects system power flow and fault current in the compensated line during a fault which affects the operation of MOVs for different fault conditions. The equivalent per-phase impedance of the MOV/capacitor circuit has an effect on the system operation

  11. Investigation of potential driver modules and transmission lines for a high frequency power system on the space station

    NASA Technical Reports Server (NTRS)

    Brush, H. T.

    1986-01-01

    The objective was to assess the feasibility of using the Series Resonant inverter as the driver module for the high frequency power system on the Space Station. This study evaluates the performance of the Series Resonant driver when it was operated with a dc input voltage and run through a series of tests to determine its start-up performance, response to load changes, load regulation, and efficiency. Also, this study compares the Series Resonant driver to another kind of driver that uses a Power Transistor snubber. An investigation of the various types of transmission lines is initiated. In particular, a simplified approach is utilized to describe the optimal transmission line.

  12. 140 W high power all-fiber laser at 1940 nm with narrow spectral line-width by MOPA configuration

    NASA Astrophysics Data System (ADS)

    Yang, C.; Ju, Y. L.; Yao, B. Q.; Dai, T. Y.; Duan, X. M.; Zhang, Z. G.; Liu, W.

    2016-08-01

    We report a diode-pumped Tm3+-doped double-clad all-fiber laser operating at 1940 nm with a master oscillator power amplifier configuration; 50 W of seed was generated in master oscillator with 144 W pump power, corresponding to a slope efficiency of 40.1 %. With 212 W pump power, the seed was amplified to 140.9 W in power amplifier, corresponding to a slope efficiency of 47.1 %. The peak wavelength was 1939.57 nm with a narrow spectral line-width of 0.09 nm. The beam quality factor of M 2 was 1.29. Neither amplified spontaneous emission nor parasitic lasing was observed during the amplification process. The output power was only limited by the pump power.

  13. Practice and power: a review and interpretive synthesis focused on the exercise of discretionary power in policy implementation by front-line providers and managers.

    PubMed

    Gilson, Lucy; Schneider, Helen; Orgill, Marsha

    2014-12-01

    Tackling the implementation gap is a health policy concern in low- and middle-income countries (LMICs). Limited attention has so far been paid to the influence of power relations over this gap. This article presents, therefore, an interpretive synthesis of qualitative health policy articles addressing the question: how do actors at the front line of health policy implementation exercise discretionary power, with what consequences and why? The article also demonstrates the particular approach of thematic synthesis and contributes to discussion of how such work can inform future health policy research. The synthesis drew from a broader review of published research on any aspect of policy implementation in LMICs for the period 1994-2009. From an initial set of 50 articles identified as relevant to the specific review question, a sample of 16 articles were included in this review. Nine report experience around decentralization, a system-level change, and seven present experience of implementing a range of reproductive health (RH) policies (new forms of service delivery). Three reviewers were involved in a systematic process of data extraction, coding, analysis, synthesis and article writing. The review findings identify: the practices of power exercised by front-line health workers and their managers; their consequences for policy implementation and health system performance; the sources of this power and health workers' reasons for exercising power. These findings also provide the basis for an overarching synthesis of experience, highlighting the importance of actors, power relations and multiple, embedded contextual elements as dimensions of health system complexity. The significance of this synthesis lies in its insights about: the micropractices of power exercised by front-line providers; how to manage this power through local level strategies both to influence and empower providers to act in support of policy goals; and the focus and nature of future research on

  14. Power and false-positive rate in QTL detection with near-isogenic line libraries.

    PubMed

    Falke, K C; Frisch, M

    2011-04-01

    Libraries of near-isogenic lines (NILs) were used for quantitative trait locus (QTL) detection in model species and economically important crops. The experimental design and genetic architecture of the considered traits determine the statistical properties of QTL detection. The objectives of our simulation study were to (i) investigate the population sizes required to develop NIL libraries in barley and maize, (ii) compare NIL libraries with nonoverlapping and overlapping donor segments and (iii) study the number of QTLs and the size of their effects with respect to the power and the false-positive rate of QTL detection. In barley, the development of NIL libraries with target segment lengths of 10 c and marker distances of 5 cM was possible using a BC(3)S(2) backcrossing scheme and population sizes of 140. In maize, population sizes larger than 200 were required. Selection for the recipient parent genome at markers flanking the target segments with distances between 5 and 10 cM was required for an efficient control of the false-positive rate. NIL libraries with nonoverlapping donor chromosome segments had a greater power of QTL detection and a smaller false-positive rate than libraries with overlapping segments. Major genes explaining 30% of the genotypic difference between the donor and recipient were successfully detected even with low heritabilities of 0.5, whereas for minor genes explaining 5 !or 10%, high heritabilities of 0.8 or 0.9 were required. The presented results can assist geneticists and breeders in the efficient development of NIL libraries for QTL detection.

  15. Characterization of vertical electric fields and associated voltages induced on a overhead power line from close artificially initiated lightning

    NASA Astrophysics Data System (ADS)

    Rubinstein, Marcos; Uman, Martin A.; Thomson, Ewen M.; Medelius, Pedro J.

    1991-08-01

    Measurements were characterized of simultaneous vertical electric fields and voltages induced at both ends of a 448 m overhead power line by artificially initiated lightning return strokes. The lightning discharges struck ground about 20 m from one end of the line. The measured line voltages could be grouped into two categories: those in which multiple, similarly shaped, evenly spaced pulses were observed, which are called oscillatory; and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which are called impulsive. Voltage amplitudes range from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages.

  16. Folsom-Nimbus 115 kV transmission line replacement for Western Area Power Administration: Environmental assessment

    SciTech Connect

    Not Available

    1980-07-01

    The Western Area Power Administration (Western) proposes to replace the existing Folsom-Nimbus 115 kV electrical transmission line along the American River between Folsom Dam and Nimbus Dam in Sacramento County, California. The need to replace the line is attributed to the deterioration of the existing wood pole structures by the acorn woodpecker; thus resulting in increased maintenance and hazard potential. The need for the replacement of the Folsom-Nimbus transmission line has resulted in the evaluation by Western of various routing alternatives. These alternatives were evaluated in terms of design, economic and environmental considerations. 60 refs., 19 figs., 4 tabs.

  17. 41 CFR 102-75.380 - May power transmission lines and rights-of-way be disposed of in other ways?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false May power transmission... REGULATION REAL PROPERTY 75-REAL PROPERTY DISPOSAL Surplus Real Property Disposal Power Transmission Lines § 102-75.380 May power transmission lines and rights-of-way be disposed of in other ways? Yes,...

  18. Renewable Energy Zones for the Africa Clean Energy Corridor

    SciTech Connect

    Wu, Grace C.; Deshmukh, Ranjit; Ndhlukula, Kudakwashe; Radojicic, Tijana; Reilly, Jessica

    2015-07-01

    Multi-criteria Analysis for Planning Renewable Energy (MapRE) is a study approach developed by the Lawrence Berkeley National Laboratory with the support of the International Renewable Energy Agency (IRENA). The approach combines geospatial, statistical, energy engineering, and economic methods to comprehensively identify and value high-quality wind, solar PV, and solar CSP resources for grid integration based on techno-economic criteria, generation profiles (for wind), and socio-environmental impacts. The Renewable Energy Zones for the Africa Clean Energy Corridor study sought to identify and comprehensively value high-quality wind, solar photovoltaic (PV), and concentrating solar power (CSP) resources in 21 countries in the East and Southern Africa Power Pools to support the prioritization of areas for development through a multi-criteria planning process. These countries include Angola, Botswana, Burundi, Djibouti, Democratic Republic of Congo, Egypt, Ethiopia, Kenya, Lesotho, Libya, Malawi, Mozambique, Namibia, Rwanda, South Africa, Sudan, Swaziland, Tanzania, Uganda, Zambia, and Zimbabwe. The study includes the methodology and the key results including renewable energy potential for each region.

  19. Reliability assessment of an OVH HV power line truss transmission tower subjected to seismic loading

    NASA Astrophysics Data System (ADS)

    Winkelmann, Karol; Jakubowska, Patrycja; Soltysik, Barbara

    2017-03-01

    The study focuses on the reliability of a transmission tower OS24 ON150 + 10, an element of an OVH HV power line, under seismic loading. In order to describe the seismic force, the real-life recording of the horizontal component of the El Centro earthquake was adopted. The amplitude and the period of this excitation are assumed random, their variation is described by Weibull distribution. The possible space state of the phenomenon is given in the form of a structural response surface (RSM methodology), approximated by an ANOVA table with directional sampling (DS) points. Four design limit states are considered: stress limit criterion for a natural load combination, criterion for an accidental combination (one-sided cable snap), vertical and horizontal translation criteria. According to these cases the HLRF reliability index β is used for structural safety assessment. The RSM approach is well suited for the analysis - it is numerically efficient, not excessively time consuming, indicating a high confidence level. Given the problem conditions, the seismic excitation is shown the sufficient trigger to the loss of load-bearing capacity or stability of the tower.

  20. Developing Effective Continuous On-Line Monitoring Technologies to Manage Service Degradation of Nuclear Power Plants

    SciTech Connect

    Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Cumblidge, Stephen E.

    2011-09-30

    Recently, there has been increased interest in using prognostics (i.e, remaining useful life (RUL) prediction) for managing and mitigating aging effects in service-degraded passive nuclear power reactor components. A vital part of this philosophy is the development of tools for detecting and monitoring service-induced degradation. Experience with in-service degradation has shown that rapidly-growing cracks, including several varieties of stress corrosion cracks (SCCs), can grow through a pipe in less than one fuel outage cycle after they initiate. Periodic inspection has limited effectiveness at detecting and managing such degradation requiring a more versatile monitoring philosophy. Acoustic emission testing (AET) and guided wave ultrasonic testing (GUT) are related technologies with potential for on-line monitoring applications. However, harsh operating conditions within NPPs inhibit the widespread implementation of both technologies. For AET, another hurdle is the attenuation of passive degradation signals as they travel though large components, relegating AET to targeted applications. GUT is further hindered by the complexity of GUT signatures limiting its application to the inspection of simple components. The development of sensors that are robust and inexpensive is key to expanding the use of AET and GUT for degradation monitoring in NPPs and improving overall effectiveness. Meanwhile, the effectiveness of AET and GUT in NPPs can be enhanced through thoughtful application of tandem AET-GUT techniques.

  1. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    PubMed

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  2. A skeptic's view of PLR effects in the magnetosphere. [Power Line Radiation

    NASA Technical Reports Server (NTRS)

    Tsurutani, B. T.; Thorne, R. M.

    1981-01-01

    A summary is provided of the current state of knowledge concerning the effects of man-made Power Line Harmonic Radiation (PLR) on the earth's magnetosphere and its energetic particle population. It is generally agreed that PLR is strongly attenuated as it propagates into the outer magnetosphere (outside the plasmasphere) and, other than rare cases where ducting occurs, the emissions either do not manage to propagate to the equatorial plane or are sufficiently reduced in amplitude to be below the sensitivity of currently orbiting plasma wave instrumentation. In either case PLR emissions are too weak to have a significant direct effect on scattering the trapped particle population; any possible effects must be indirect. It has, therefore, been postulated that PLR can act as an 'embryonic emission' for triggering intense whistler mode 'chorus', which then via cyclotron resonant interactions, cause particle pitch-angle scattering. Points of disagreement are related to the geographic distribution of chorus, the chorus starting frequency, the Sunday effect, and PLR effects within the plasmasphere.

  3. A Study on the Performance of Wavelet OFDM in Power Line

    NASA Astrophysics Data System (ADS)

    Koga, Hisao; Kodama, Nobutaka

    Recently, the demand of high speed network in home is increasing. Some Multicarrier Modulation (MCM) based systems use FFT OFDM, and some use a Wavelet OFDM in place of FFT OFDM. Wavelet transforms consist of an M-band transmultiplexers, which use filters of greater length than the rectangular windows used in FFT OFDM. The use of symbols of longer duration allows obtaining lower side-lobe levels with respect to FFT OFDM. Better stop-band attenuation results in both lower levels of inter-carrier interference (ICI) and greater robustness to narrowband interference. For the power line channel, we have chosen two channels measured by network analyzer. The root mean square (R.M.S.) delay spreads of Channels A and B are 0.22 [μsec] and 1.1 [μsec], respectively. In this paper, the PHY (Physical layer) data rates [Mbps] achievable by Wavelet OFDM over Channels A and B are shown for two different kinds of FEC. Then, the effects of ISI and ICI on Wavelet OFDM can be compensated by increasing the number of carriers. Finally, it is shown that Wavelet OFDM characteristic is better than that of FFT OFDM about PHY rates [Mbps] with the same channels.

  4. Imprint of DESI fiber assignment on anisotropic power spectrum of emission line galaxies

    NASA Astrophysics Data System (ADS)

    Cahn, Robert N.; Pinol, Lucas; Hand, Nicholas; McDonald, Patrick; Seljak, Uros

    2017-01-01

    The Dark Energy Spectroscopic Instrument (DESI), a multiplexed fiber-fed spectrograph, is a Stage-IV ground-based dark energy experiment aiming to measure redshifts for 29 million Emission-Line Galaxies (ELG), 4 million Luminous Red Galaxies (LRG), and 2 million Quasi-Stellar Objects (QSO). The survey design includes an observation strategy determined by a fiber assignment algorithm that optimizes the allocation of fibers to targets. We investigate the systematic effects of the fiber assignment coverage on the anisotropic galaxy clustering of ELGs and show that, in the absence of any corrections, it leads to discrepancies of order ten percent on large scales for the power spectrum multipoles. We introduce a method where objects in a random catalog are assigned a coverage, and the mean density is separately computed for each coverage factor, and show that this method reduces, but does not eliminate the effect. The angular dependence of the contaminating signal is mostly in purely transverse modes. We find that the effect can be mitigated by binning in angle and excluding contributions near the transverse direction. This material is based upon work supported in part by the U.S. Department of Energy, Office of Science, Office of High Energy Physics, under Contract No. DE-AC02-05CH11231.

  5. Electrocution of Raptors on Power Lines: A Review of Necropsy Methods and Findings.

    PubMed

    Kagan, R A

    2016-09-01

    Decades after the problem was first identified, power line electrocution continues to be a cause of avian mortality. Currently, several federal laws protect eagles and other migratory birds, meaning that utility companies may be liable for electrocution-related deaths. Veterinarians and veterinary pathologists called upon to diagnose and treat electrocuted birds should keep this in mind when conducting clinical and postmortem examinations. This review details necropsy findings and methods used to diagnose electrocution. A combination of gross, subgross, and radiographic examinations can aid in identification of subtle injury. Diagnosis is made based on the presence of skin and/or feather burns. Other necropsy findings may include skin lacerations, subcutaneous burns, bruising, limb avulsion, hemopericardium, and vascular rupture. At the US Fish and Wildlife Service's National Forensics Laboratory, from 2000 to 2015, 417 raptor deaths were determined to have been caused by electrocution. Bald eagles and golden eagles were the most commonly submitted species. In a retrospective review of 377 cases, for which whole bodies were submitted, 18% of the electrocuted birds had only a single, small (less than 3 cm in diameter) external burn. Small, isolated burns tended to occur on the undersides of the wings at and distal to the elbow and on the lower legs and feet. These areas should be most carefully examined in cases where electrocution injury is not immediately apparent.

  6. Requirements Definition for ORNL Trusted Corridors Project

    SciTech Connect

    Walker, Randy M; Hill, David E; Smith, Cyrus M; DeNap, Frank A; White, James D; Gross, Ian G; Gorman, Bryan L; Hively, Lee M; Abercrombie, Robert K

    2008-02-01

    The ORNL Trusted Corridors Project has several other names: SensorNet Transportation Pilot; Identification and Monitoring of Radiation (in commerce) Shipments (IMR(ic)S); and Southeastern Transportation Corridor Pilot (SETCP). The project involves acquisition and analysis of transportation data at two mobile and three fixed inspection stations in five states (Kentucky, Mississippi, South Carolina, Tennessee, and Washington DC). Collaborators include the State Police organizations that are responsible for highway safety, law enforcement, and incident response. The three states with fixed weigh-station deployments (KY, SC, TN) are interested in coordination of this effort for highway safety, law enforcement, and sorting/targeting/interdiction of potentially non-compliant vehicles/persons/cargo. The Domestic Nuclear Detection Office (DNDO) in the U.S. Department of Homeland Security (DHS) is interested in these deployments, as a Pilot test (SETCP) to identify Improvised Nuclear Devices (INDs) in highway transport. However, the level of DNDO integration among these state deployments is presently uncertain. Moreover, DHS issues are considered secondary by the states, which perceive this work as an opportunity to leverage these (new) dual-use technologies for state needs. In addition, present experience shows that radiation detectors alone cannot detect DHS-identified IND threats. Continued SETCP success depends on the level of integration of current state/local police operations with the new DHS task of detecting IND threats, in addition to emergency preparedness and homeland security. This document describes the enabling components for continued SETCP development and success, including: sensors and their use at existing deployments (Section 1); personnel training (Section 2); concept of operations (Section 3); knowledge discovery from the copious data (Section 4); smart data collection, integration and database development, advanced algorithms for multiple sensors, and

  7. High-harmonic fast-wave power flow along magnetic field lines in the scrape-off layer of NSTX.

    PubMed

    Perkins, R J; Hosea, J C; Kramer, G J; Ahn, J-W; Bell, R E; Diallo, A; Gerhardt, S; Gray, T K; Green, D L; Jaeger, E F; Jaworski, M A; LeBlanc, B P; McLean, A; Maingi, R; Phillips, C K; Roquemore, L; Ryan, P M; Sabbagh, S; Taylor, G; Wilson, J R

    2012-07-27

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

  8. Corridors and some ecological and evolutionary consequences of connectivity.

    SciTech Connect

    Orrock, John L

    2004-07-01

    Abstract - By connecting disjunct patches, corridors may offset the effects of fragmentation by promoting gene flow and population persistence. However, the ultimate effect of corridors on a focal species may hinge upon two considerations: how corridors may affect ecological interactions that impinge upon that species, and how corridors might affect the fixation of novel alleles that ultimately determine fitness and persistence. Using an experimental landscape, I show that corridor-mediated changes in patch shape change seed predation in connected and unconnected patches, and shift the behavior, abundance, and distribution of seed predators. Rodent seed predators removed more seeds in connected patches, arthropod seed predators removed more seeds in rectangular patches, and avian seed predation did not differ due to patch type. Rodent foraging was greater in the interior of connected patches because changes in patch shape influenced risk perceived by rodents while foraging. Ant communities were also affected by changes in patch shape caused by corridors, rather than corridor effects per se. The distribution and abundance of ants differed among edge-rich areas (corridors and wings), edges, and the patch interior. In rectangular patches, fire ants (Solenopsis spp.) had negative impacts on other ant species. By changing the activity of rodents, and the composition of ant communities, corridors may have important impacts on seeds. Bird-dispersed seeds may benefit from increased dispersal among connected patches, but connected patches also have greater predation risk. Using a simulation model, I demonstrate that gene flow between a stable population and a population that experiences local extinction or a reduction in size (e.g. due to natural or anthropogenic disturbance) can dramatically affect fixation of alleles in the stable population. Alone or in concert, frequent disturbance, high rates of movement, and low habitat quality make it more likely that connectivity

  9. Assessment of electromagnetic field levels from surrounding high-tension overhead power lines for proposed land use.

    PubMed

    Al-Bassam, E; Elumalai, A; Khan, A; Al-Awadi, L

    2016-05-01

    The surrounding outdoor environment for new development has a big effect on the indoor quality of life. The main aim of this work was to determine the suitability of the area for building new schools with reference to electromagnetic field (EMF) effects. The specific objective of this study was to detect the safe distance from the EMF posed by the high-tension overhead power lines in the vicinity of the specified area. The measurements were taken for both the electric and magnetic fields in different months in order to detect the highest EMF levels during the peak power load season. EMDEX II with E-probe and EMDEX II with Linda were used for the measurements. These instruments were all calibrated by ENERTECH Company in USA. The EMF associated with high tension transmission lines that surrounded the proposed site has to be below 0.2 μT (Italian EMF regulations are the most suitable regulations for the establishment of schools in Kuwait). The safety clearance distance from the existing 300-kV high-tension power line has been assigned as 200 m and from other existing 132-kV high-tension power line was 50 m. The proposed site with its predefined boundaries has a magnetic field below the Italian EMF regulations for the establishment of new schools.

  10. Cryogenic-temperature profiling of high-power superconducting lines using local and distributed optical-fiber sensors.

    PubMed

    Chiuchiolo, Antonella; Palmieri, Luca; Consales, Marco; Giordano, Michele; Borriello, Anna; Bajas, Hugues; Galtarossa, Andrea; Bajko, Marta; Cusano, Andrea

    2015-10-01

    This contribution presents distributed and multipoint fiber-optic monitoring of cryogenic temperatures along a superconducting power transmission line down to 30 K and over 20 m distance. Multipoint measurements were conducted using fiber Bragg gratings sensors coated with two different functional overlays (epoxy and poly methyl methacrylate (PMMA)) demonstrating cryogenic operation in the range 300-4.2 K. Distributed measurements exploited optical frequency-domain reflectometry to analyze the Rayleigh scattering along two concatenated fibers with different coatings (acrylate and polyimide). The integrated system has been placed along the 20 m long cryostat of a superconducting power transmission line, which is currently being tested at the European Organization for Nuclear Research (CERN). Cool-down events from 300-30 K have been successfully measured in space and time, confirming the viability of these approaches to the monitoring of cryogenic temperatures along a superconducting transmission line.

  11. Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels

    SciTech Connect

    Stoffel, J. B.; Pentecost, E. D.; Roman, R. D.; Traczyk, P. A.

    1994-11-01

    The aim of this report is to provide background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist preparers and reviewers of the section on alternatives in environmental documents. This report will give the reviewing individual a better appreciation of the factors affecting EMF strengths near high-voltage transmission lines and the approaches that might be used to reduce EMF impacts on humans and other biological species in the vicinity of high-voltage overhead or underground alternating-current (ac) or direct-current (dc) transmission lines.

  12. Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

    SciTech Connect

    Millsap, William J.; Brush, Daniel J.

    2013-11-13

    This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methods included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using "background makers"; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra.

  13. 26. Interior of elevator, view from corridor. Thalheimer Whiteman ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. Interior of elevator, view from corridor. Thalheimer - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  14. 22. Axial view along north cell corridor, cells at right; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. Axial view along north cell corridor, cells at right; view to southwest, 65mm lens with electronic flash illumination. - Tule Lake Project Jail, Post Mile 44.85, State Route 139, Newell, Modoc County, CA

  15. Facility No. 175, interior overview from secondfloor corridor on northwest ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Facility No. 175, interior overview from second-floor corridor on northwest side - U.S. Naval Base, Pearl Harbor, Landplane Hangar Type, Wasp Boulevard and Gambier Bay Street, Pearl City, Honolulu County, HI

  16. Interior view of connecting corridor looking from pavilion "B" to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view of connecting corridor looking from pavilion "B" to "A" (original west pavilion to convalescent pavilion). - National Home for Disabled Volunteer Soldiers, Northwestern Branch, Hospital, 5000 West National Avenue, Milwaukee, Milwaukee County, WI

  17. 76 FR 3695 - Environmental Impact Statement: Interstate 64 Corridor, Virginia

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-20

    ... Federal Highway Administration Environmental Impact Statement: Interstate 64 Corridor, Virginia AGENCY... Administration is issuing this notice to advise the public of its intent to prepare an Environmental Impact..., Senior Environmental Specialist, Federal Highway Administration, Post Office Box 10249,...

  18. 37. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, NORTH OF ELEVATOR LOBBY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, NORTH OF ELEVATOR LOBBY 4, EAST WALL, AMERICAN BISON MURAL (4' x 5' negative; 8' x 10' print) - U.S. Department of the Interior, Eighteenth & C Streets Northwest, Washington, District of Columbia, DC

  19. 7. VIEW, LOOKING SOUTHEAST, SHOWING SOUTH HALF OF EAST CORRIDOR, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW, LOOKING SOUTHEAST, SHOWING SOUTH HALF OF EAST CORRIDOR, RANGE 5, WITH CENTRAL ROOF SUPPORTS, Interior - Winchester Repeating Arms Company, Tract K Shooting Range, 125 Munson Street (rear section), New Haven, New Haven County, CT

  20. 48. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS AND CRAFTS SHOP, SOUTH WALL, DEER STALKING MURAL - U.S. Department of the Interior, Eighteenth & C Streets Northwest, Washington, District of Columbia, DC

  1. Vault Area (original section), south corridor, looking west Fort ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), south corridor, looking west - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  2. Vault Area (original section), east corridor, interior of Vault No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, interior of Vault No. 7, looking up flue - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  3. Vault Area (original section), east corridor, interior of Vault No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, interior of Vault No. 7, view west - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  4. Vault Area (original section), east corridor, Vault No. 3 showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, Vault No. 3 showing inside surface of outer door - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  5. Vault Area (original section), east corridor, looking north (Vault Nos. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, looking north (Vault Nos. 1-9 - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  6. EXTERIOR DOOR DETAIL, CORRIDOR 137, FACING EAST Cape Canaveral ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    EXTERIOR DOOR DETAIL, CORRIDOR 137, FACING EAST - Cape Canaveral Air Force Station, Launch Complex 34, Operations Support Building, Freedom Road, Southwest of Launch Stand CX-34, Cape Canaveral, Brevard County, FL

  7. DETAIL OF ELECTRICAL PANEL, CORRIDOR 137 Cape Canaveral Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF ELECTRICAL PANEL, CORRIDOR 137 - Cape Canaveral Air Force Station, Launch Complex 34, Operations Support Building, Freedom Road, Southwest of Launch Stand CX-34, Cape Canaveral, Brevard County, FL

  8. 41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106455. FLUOR NUMBER 5775-CPP-633-P-60 - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  9. 11. View of east entry to central corridor of filtration ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. View of east entry to central corridor of filtration bed building. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  10. 32. Piping under central corridor of filtration bed building. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. Piping under central corridor of filtration bed building. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  11. 31. Piping under central corridor of filtration bed building. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. Piping under central corridor of filtration bed building. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  12. 13. View of west entrance to central corridor of filtration ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. View of west entrance to central corridor of filtration bed building. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  13. 28. Main water inlet and outlet pipes under central corridor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. Main water inlet and outlet pipes under central corridor of filtration bed building. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  14. VIEW OF BOTTOMLAND FOREST, WEST OF RAILROAD CORRIDOR, NORTH OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF BOTTOMLAND FOREST, WEST OF RAILROAD CORRIDOR, NORTH OF OVERHILLS LAKE, FACING WEST - Overhills, Fort Bragg Military Reservation, Approximately 15 miles NW of Fayetteville, Overhills, Harnett County, NC

  15. 49. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS AND CRAFTS SHOP, DETAIL OF DECORATIVE BEAM, CORBEL, AND CEILING - U.S. Department of the Interior, Eighteenth & C Streets Northwest, Washington, District of Columbia, DC

  16. 35. INTERIOR, FIRST (AND SECOND) FLOOR, MAIN CORRIDOR AND SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. INTERIOR, FIRST (AND SECOND) FLOOR, MAIN CORRIDOR AND SOUTH FOYER, DETAIL OF BRONZE BUILDING DIRECTORY (4' x 5' negative; 8' x 10' print) - U.S. Department of the Interior, Eighteenth & C Streets Northwest, Washington, District of Columbia, DC

  17. First floor corridor, looking west towards the lobby. The entrance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First floor corridor, looking west towards the lobby. The entrance to the display area (room 101) is located directly behind the camera - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  18. Ego-Vehicle Corridors for Vision-Based Driver Assistance

    NASA Astrophysics Data System (ADS)

    Jiang, Ruyi; Klette, Reinhard; Vaudrey, Tobi; Wang, Shigang

    Improving or generalizing lane detection solutions on curved roads with possibly broken lane marks is still a challenging task. This paper proposes a concept of a (virtual) corridor for modeling the space an ego-vehicle is able to drive through, using available (but often incomplete, e.g., due to occlusion, road conditions, or road intersections) information about the lane marks but also about the motion and relative position (with respect to the road) of the ego-vehicle. A corridor is defined in this paper by special features, such as two fixed starting points, a constant width, and a unique relationship with visible lane marks. Robust corridor detection is possible by hypothesis testing based on maximum a posterior (MAP) estimation, followed by boundary selection, and road patch extension. Obstacles are explicitly considered. A corridor tracking method is also discussed. Experimental results are provided.

  19. 14. Control Area, Interconnecting Corridor and Frequency Changer and Generator ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Control Area, Interconnecting Corridor and Frequency Changer and Generator Building, general view VIEW SOUTHWEST, NORTH ELEVATION - NIKE Missile Battery PR-79, Control Area, Tucker Hollow Road south of State Route 101, Foster, Providence County, RI

  20. 50. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. INTERIOR, FIRST FLOOR, MAIN CORRIDOR, ROOM 1023, INDIAN ARTS AND CRAFTS SHOP, DETAIL OF TIN LIGHTING SCONCE - U.S. Department of the Interior, Eighteenth & C Streets Northwest, Washington, District of Columbia, DC

  1. 76 FR 65561 - Multistate Corridor Operations and Management Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-21

    ... Federal Highway Administration Multistate Corridor Operations and Management Program AGENCY: Federal... Operations and Management (MCOM) Program authorized by the Safe, Accountable, Flexible, Efficient... transportation challenges facing the efficient and effective operation and management of...

  2. High-voltage overhead power lines in epidemiology: patterns of time variations in current load and magnetic fields.

    PubMed

    Reitan, J B; Tynes, T; Kvamshagen, K A; Vistnes, A I

    1996-01-01

    In epidemiological studies of electromagnetic fields and health effects, exposure classification is crucial. There is no generally accepted biophysical interaction mechanism, but many studies are based on the hypothesis of a causal relationship with the strength of magnetic field. Some definition of the magnitude of exposure must be used, e.g., mean magnetic flux density, the integral of magnetic flux and time, or a peak value. Magnetic fields around a particular power line depend on the current load. The aim of the present study was to follow variations in line current load in the power supply system of the largest Norwegian city on a yearly, monthly, daily and diurnal basis. Fairly large variations in load were found, but increases in consumption were not necessarily reflected in current load on high voltage lines. The correlation between outdoor temperature and current load varied widely, depending on the type of power station feeding the line in question. The registered time variations are large enough to interfere with epidemiological classification of residences and testing of epidemiological hypotheses.

  3. Northeast corridor improvement project draft environmental impact statement/report for electrification of Northwest Corridor, New Haven, CT. To Boston, MA. Volume 1. Final report, September 1992-September 1993

    SciTech Connect

    Not Available

    1993-09-01

    The impacts of extending electrification on the National Railroad Passenger Corporation's (Amtrak) Northeast Corridor (NEC) from New Haven, Connecticut to Boston, Massachusetts are of direct concern to the Federal Railroad Administration (FRA). To improve rail service and increase ridership between New York and Boston, Amtrak proposes the electrification of the NEC main line between New Haven, CT and Boston, MA using an overhead 2 X 25,000 volt - 60 hertz power system. This volume considers impacts on the Human and Natural Environment utilizing guidance as outlined in CFR Part 1500, Council on Environmental Quality, Regulations for Implementing the Procedural Requirements of NEPA as amended and the Massachusetts Environmental Policy Act (MEPA) regulations (301 CMR 11:00). Impacts analyzed include changes in the natural environment (air quality, noise and vibration, energy, electromagnetic fields, natural resources, hazardous materials and visual/aesthetics), changes in the social environment (land use and recreation, transportation and traffic), impacts on historic and archaeological sites, changes in transit service and patronage, associated changes in highway and airport congestion, capital costs, operating and maintenance costs, and financial implications. Impacts are identified both for the proposed construction period and for the long-term operation of the alternatives.

  4. Photovoltaic power system tests on an 8-kilowatt single-phase line-commutated inverter

    NASA Technical Reports Server (NTRS)

    Stover, J. B.

    1978-01-01

    Efficiency and power factor were measured as functions of solar array voltage and current. The effects of input shunt capacitance and series inductance were determined. Tests were conducted from 15 to 75 percent of the 8 kW rated inverter input power. Measured efficiencies ranged from 76 percent to 88 percent at about 50 percent of rated inverter input power. Power factor ranged from 36 percent to 72 percent.

  5. Fast-wave Power Flow Along SOL Field Lines In NSTX nd The Associated Power Deposition Profile Across The SOL In Front Of The Antenna

    SciTech Connect

    Perkins, Roy

    2013-06-21

    Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface (LCFS) as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. Advanced RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER.

  6. Corridors and olfactory predator cues affect small mammal behavior.

    SciTech Connect

    Brinkerhoff, Robert Jory; Haddad, Nick M.; Orrock, John L.

    2005-03-30

    Abstract The behavior of prey individuals is influenced by a variety of factors including, but not limited to, habitat configuration, risk of predation, and availability of resources, and these habitat-dependent factors may have interactive effects. We studied the responses of mice to an increase in perceived predation risk in a patchy environment to understand how habitat corridors might affect interactions among species in a fragmented landscape. We used a replicated experiment to investigate corridor-mediated prey responses to predator cues in a network of open habitat patches surrounded by a matrix of planted pine forest. Some of the patches were connected by corridors. We used mark–recapture techniques and foraging trays to monitor the movement, behavior, and abundance of small mammals. Predation threat was manipulated in one-half of the replicates by applying an olfactory predator cue. Corridors synchronized small mammal foraging activity among connected patches. Foraging also was inhibited in the presence of an olfactory predator cue but apparently increased in adjacent connected patches. Small mammal abundance did not change as a result of the predator manipulation and was not influenced by the presence of corridors. This study is among the 1st to indicate combined effects of landscape configuration and predation risk on prey behavior. These changes in prey behavior may, in turn, have cascading effects on community dynamics where corridors and differential predation risk influence movement and patch use.

  7. Coaxial line configuration for microwave power transmission study of YBa2Cu3O(7-delta) thin films

    NASA Technical Reports Server (NTRS)

    Chorey, C. M.; Miranda, F. A.; Bhasin, K. B.

    1991-01-01

    Microwave transmission measurements through YBa2Cu3O(7-delta) (YBCO) high-transition-temperature superconducting thin films on lanthanum aluminate (LaAlO3) have been performed in a coaxial line at 10 GHz. LaAlO3 substrates were ultrasonically machined into washer-shaped discs, polished, and coated with laser-ablated YBCO. These samples were mounted in a 50-ohm coaxial air line to form a short circuit. The power transmitted through the films as a function of temperature was used to calculate the normal state conductivity and the magnetic penetration depth for the films.

  8. Coaxial line configuration for microwave power transmission study of YBa2Cu3O(7-delta) thin films

    NASA Astrophysics Data System (ADS)

    Chorey, C. M.; Miranda, F. A.; Bhasin, K. B.

    1991-12-01

    Microwave transmission measurements through YBa2Cu3O(7-delta) (YBCO) high-transition-temperature superconducting thin films on lanthanum aluminate (LaAlO3) have been performed in a coaxial line at 10 GHz. LaAlO3 substrates were ultrasonically machined into washer-shaped discs, polished, and coated with laser-ablated YBCO. These samples were mounted in a 50-ohm coaxial air line to form a short circuit. The power transmitted through the films as a function of temperature was used to calculate the normal state conductivity and the magnetic penetration depth for the films.

  9. Wood and Sediment Dynamics in River Corridors

    NASA Astrophysics Data System (ADS)

    Wohl, E.; Scott, D.

    2015-12-01

    Large wood along rivers influences entrainment, transport, and storage of mineral sediment and particulate organic matter. We review how wood alters sediment dynamics and explore patterns among volumes of instream wood, sediment storage, and residual pools for dispersed pieces of wood, logjams, and beaver dams. We hypothesized that: volume of sediment per unit area of channel stored in association with wood is inversely proportional to drainage area; the form of sediment storage changes downstream; sediment storage correlates most strongly with wood load; and volume of sediment stored behind beaver dams correlates with pond area. Lack of data from larger drainage areas limits tests of these hypotheses, but analyses suggest a negative correlation between sediment volume and drainage area and a positive correlation between wood and sediment volume. The form of sediment storage in relation to wood changes downstream, with wedges of sediment upstream from jammed steps most prevalent in small, steep channels and more dispersed sediment storage in lower gradient channels. Use of a published relation between sediment volume, channel width, and gradient predicted about half of the variation in sediment stored upstream from jammed steps. Sediment volume correlates well with beaver pond area. Historically more abundant instream wood and beaver populations likely equated to greater sediment storage within river corridors. This review of the existing literature on wood and sediment dynamics highlights the lack of studies on larger rivers.

  10. RIVER CORRIDOR BUILDINGS 324 & 327 CLEANUP

    SciTech Connect

    BAZZELL, K.D.; SMITH, B.A.

    2006-02-09

    A major challenge in the recently awarded River Corridor Closure (RCC) Contract at the U.S. Department of Energy's (DOE) Hanford Site is decontaminating and demolishing (D&D) facilities in the 300 Area. Located along the banks of the Columbia River about one mile north of Richland, Washington, the 2.5 km{sup 2} (1 mi{sup 2})300 Area comprises only a small part of the 1517 km{sup 2} (586 mi{sup 2}) Hanford Site. However, with more than 300 facilities ranging from clean to highly contaminated, D&D of those facilities represents a major challenge for Washington Closure Hanford (WCH), which manages the new RCC Project for DOE's Richland Operations Office (RL). A complicating factor for this work is the continued use of nearly a dozen facilities by the DOE's Pacific Northwest National Laboratory (PNNL). Most of the buildings will not be released to WCH until at least 2009--four years into the seven-year, $1.9 billion RCC Contract. The challenge will be to deactivate, decommission, decontaminate and demolish (D4) highly contaminated buildings, such as 324 and 327, without interrupting PNNL's operations in adjacent facilities. This paper focuses on the challenges associated with the D4 of the 324 Building and the 327 Building.

  11. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... communication lines over reservoirs. 222.3 Section 222.3 Navigation and Navigable Waters CORPS OF ENGINEERS... communication lines over reservoirs. (a) Purpose. This regulation prescribes the minimum vertical clearances to... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having...

  12. Nuclear techniques for the on-line bulk analysis of carbon in coal-fired power stations.

    PubMed

    Sowerby, B D

    2009-09-01

    Carbon trading schemes usually require large emitters of CO(2), such as coal-fired power stations, to monitor, report and be audited on their CO(2) emissions. The emission price provides a significant additional incentive for power stations to improve efficiency. In the present paper, previous work on the bulk determination of carbon in coal is reviewed and assessed. The most favourable method is that based on neutron inelastic scattering. The potential role of on-line carbon analysers in improving boiler efficiency and in carbon accounting is discussed.

  13. Centaur feedline dynamics study using power spectral methods. [fundamental mode resonant frequencies of RL-10 oxygen and hydrogen feed lines

    NASA Technical Reports Server (NTRS)

    Lorenzo, C. F.

    1974-01-01

    Tests were conducted to determine the dynamic characteristics of the Centaur/RL-10 oxygen and hydrogen feedlines. The fundamental-mode resonant frequencies were determined by applying power spectral methods to noise-generated data from hot firings of the RL-10 engine. The effect of net positive suction pressure of the main feed pumps on resonant frequency characteristics was determined to be a straight-line relation. Power spectral methods were also used to determine the dynamic characteristics of the boost pumps.

  14. ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED WITHDRAWAL OF PUBLIC LANDS WITHIN AND SURROUNDING THE CALIENTE RAIL CORRIDOR, NEVADA

    SciTech Connect

    DOE

    2005-12-01

    The purpose for agency action is to preclude surface entry and the location of new mining claims, subject to valid existing rights, within and surrounding the Caliente rail corridor as described in the Yucca Mountain FEIS (DOE 2002). This protective measure is needed to enhance the safe, efficient, and uninterrupted evaluation of land areas for potential rail alignments within the Caliente rail corridor. The evaluation will assist the DOE in determining, through the Rail Alignment environmental impact statement (EIS) process, whether to construct a branch rail line, and to provide support to the BLM in deciding whether or not to reserve a ROW for the rail line under the Federal Land Policy and Management Act (FLPMA). The BLM participated as a cooperating agency in preparing this EA because it is the responsible land manager and BLM staff could contribute resource specific expertise.

  15. Design concepts for a pulse power test facility to simulate EMP surges in overhead power lines. Part I. Fast pulse

    SciTech Connect

    Ramrus, A.

    1986-02-01

    Objective of the study was to create conceptual designs of high voltage pulsers capable of simulating two types of electromagnetic pulses (EMPs) caused by a high-altitude nuclear burst; the slow rise time magnetohydrodynamic (MHD-EMP) and the fast rise time high-altitude EMP (HEMP). The pulser design was directed towards facilities capable of performing EMP vulnerability testing of components used in the national electric power system.

  16. Power Line Noise in Transient Electromagnetic (TEM) Data: Identification and Removal in a Practical Field Study.

    NASA Astrophysics Data System (ADS)

    Jernsletten, J. A.

    2004-05-01

    INTRODUCTION: To evaluate the appropriateness of TEM in mapping deep groundwater tables (in Mars analog environmnets), a field study was carried out in the desert ~30 miles SW of Tucson, Arizona. The study was also designed to observe effects of powerline noise on TEM data. The clay-rich soil in the area is quite conductive. The study consisted of 40 in-loop TEM stations, divided into 3 lines, for 4 line-km of data. The survey was carried out by a crew of one person, with square Tx wire loops 100 m on a side, and a ferrite-core magnetic coil Rx antenna in the center of each Tx loop. Maximum useful depth of investigation achieved was ~600 m. TEM DATA: The field area is surrounded by powerlines on all 4 sides: Line 1 has the outside of the first Tx loop under the powerline to the West; Line 2 starts with the powerline to the North passing above just inside its first Tx loop, and ends with the outside of the last station's transmitter loop ~20 m shy of the powerline to the South; finally, Line 3 starts ~50 m East of the powerline to the West, and runs parallel to the powerline to the South along its entire length, at a separation distance of ~70 m. Line 3 was placed largely in an effort to obeserve powerline noise. The decay curve for the first station on Line 1(Line 1/Station 50) is raised above the other curves from Line 1. This is due to the charge (noise) from the adjacent powerline, which is at a distance of ~50 m from the Rx coil. In effect, the transient decay is recorded as being slower than it would be without the presence of the powerline. This also artficially lowers the apparent resistivity, readily observed in Line 1/Station 50 data. These effects are present to a lesser extent (lower magnitude noise) in the data from Line1/Station 150, the second station on Line 1. On the smooth-model inversion cross-section of the data from Line 1, the effects of the powerline noise appears as a pulling up of the low-resistivity water table contact towards the surface

  17. Relationship between Emergency Restoration Time of Power Distribution Line after a Disaster and Geographical Characteristics of its Area

    NASA Astrophysics Data System (ADS)

    Sagai, Shigeo; Terano, Takao

    The effect of an outage caused by a disaster is serious to the society, because the power distribution line is a common basic infrastructure for life support. And the time estimation of emergency restoration process of power distribution line after a disaster is an emerging problem for the safety and security of the society. But the time estimation is a difficult problem and the only practical method in use is a simple approximation method, which doesn't take account of geographical characteristics of the objective area. So, we developed a method which can take account of the influences caused by the geographical characteristics of the objective area on the estimation of the emergency restoration. In this article, we describe an experimental analysis by the method.

  18. Development of An On-Line, Core Power Distribution Monitoring System

    SciTech Connect

    Tunc ALdemir; Don Miller; Peng Wang

    2007-10-02

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  19. Test Results from a Simulated High Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

  20. Test Results From a Simulated High-Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

  1. Number of lightning discharges causing damage to lightning arrester cables for aerial transmission lines in power systems

    SciTech Connect

    Nikiforov, E. P.

    2009-07-15

    Damage by lightning discharges to lightning arrester cables for 110-175 kV aerial transmission lines is analyzed using data from power systems on incidents with aerial transmission lines over a ten year operating period (1997-2006). It is found that failures of lightning arrester cables occur when a tensile force acts on a cable heated to the melting point by a lightning current. The lightning currents required to heat a cable to this extent are greater for larger cable cross sections. The probability that a lightning discharge will develop decreases as the amplitude of the lightning current increases, which greatly reduces the number of lightning discharges which damage TK-70 cables compared to TK-50 cables. In order to increase the reliability of lightning arrester cables for 110 kV aerial transmission lines, TK-70 cables should be used in place of TK-50 cables. The number of lightning discharges per year which damage lightning arrester cables is lowered when the density of aerial transmission lines is reduced within the territory of electrical power systems. An approximate relationship between these two parameters is obtained.

  2. Optimization of fluid line sizes with pumping power penalty IBM-360 computer program

    NASA Technical Reports Server (NTRS)

    Jelinek, D.

    1972-01-01

    Computer program has been developed to calculate and total weights for tubing, fluid in tubing, and weight of fuel cell power source necessary to power pump based on flow rate and pressure drop. Program can be used for fluid systems used in any type of aircraft, spacecraft, trucks, ships, refineries, and chemical processing plants.

  3. Cancer cell line identification by short tandem repeat profiling: power and limitations.

    PubMed

    Parson, Walther; Kirchebner, Romana; Mühlmann, Roswitha; Renner, Kathrin; Kofler, Anita; Schmidt, Stefan; Kofler, Reinhard

    2005-03-01

    Cancer cell lines are used worldwide in biological research, and data interpretation depends on unambiguous attribution of the respective cell line to its original source. Short-tandem-repeat (STR) profiling (DNA fingerprinting) is the method of choice for this purpose; however, the genetic stability of cell lines under various experimental conditions is not well defined. We tested the effect of long-term culture, subcloning, and generation of drug-resistant subclones on fingerprinting profiles in four widely used leukemia cell lines. The DNA fingerprinting profile remained unaltered in two of them (U937 and K562) throughout 12 months in culture, and the vast majority of subclones derived therefrom by limiting dilution after long-term culture revealed the same profile, indicating a high degree of stability and clonotypic homogeneity. In contrast, two other cell lines (CCRF-CEM and Jurkat) showed marked alterations in DNA fingerprinting profiles during long-term culture. Limiting dilution subcloning revealed extensive clonotypic heterogeneity with subclones differing in up to eight STR loci from the parental culture. Similar heterogeneity was observed in subclones generated by selection culture for drug resistance where DNA fingerprinting proved useful in identifying possible resistance mechanisms. Thus, common tissue culture procedures may dramatically affect the fingerprinting profile of certain cell lines and thus render definition of their origin difficult.

  4. Big Creek Hydroelectric System, East & West Transmission Line, 241mile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Big Creek Hydroelectric System, East & West Transmission Line, 241-mile transmission corridor extending between the Big Creek Hydroelectric System in the Sierra National Forest in Fresno County and the Eagle Rock Substation in Los Angeles, California, Visalia, Tulare County, CA

  5. Final environmental impact statement/report. Volume 4. Comment letters and public hearing transcripts. Northeast corridor improvement project electrication: New Haven, CT to Boston, MA

    SciTech Connect

    1994-10-01

    This document is the final environmental impact statement and final environmental impact report (FEIS/R) on the proposal by the National Railroad Passenger Corporation (Amtrak) to complete the electrification of the Northeast Corridor main line by extending electric traction from New Haven, CT, to Boston, MA. This document (Volume IV) reprints the comments received on the DEIS/R.

  6. A Study on Modeling of Transmission Line in Digital Type Real-Time Power System Simulator

    NASA Astrophysics Data System (ADS)

    Yasuda, Yuji; Yokoyama, Akihiko; Tada, Yasuyuki

    In modern power systems, it is important to analyze various kindes of dynamic phenomena which appear in the system. When the effectiveness of new power electronics based apparatus, protective relay systems and etc. is tested, a real-time power system simulator is becoming a very effective tool. In general, however, it is very expensive and it is very difficult for beginners to understand how to use it. Therefore, studies on low-cost and easy-use real-time power system simulators have so far been done. We have developed models of power system components for the real-time power system simulator using DSP (Digital Signal Processor) combined with commercial CAD (Computer Aided Design) soft "MATLAB/SIMULINK". The use of commercial softwares can drastically decrease the development cost of the simulator. In this paper, a simplified reduction model of unbalanced three-phase transmission network with mutual impedance is proposed for analysis of various kinds of stability phenomena by use of the digital simulator. The proposed network model is constructed automatically and efficiently even for connection of both current source type models and voltage source type models of power apparatus such as generators, FACTS devices and loads.

  7. Cell-line selectivity improves the predictive power of pharmacogenomic analyses and helps identify NADPH as biomarker for ferroptosis sensitivity

    PubMed Central

    Shimada, Kenichi; Hayano, Miki; Pagano, Nen; Stockwell, Brent

    2016-01-01

    Precision medicine in oncology requires not only identification of cancer-associated mutations, but also effective drugs for each cancer genotype, which is still a largely unsolved problem. One approach for the latter challenge has been large-scale testing of small molecules in genetically characterized cell lines. We hypothesized that compounds with high cell-line-selective lethality exhibited consistent results across such pharmacogenomic studies. We analyzed the compound sensitivity data of 6,259 lethal compounds from the NCI-60 project. 2,565 cell-line-selective lethal compounds were identified and grouped into 18 clusters based on their GI50 profiles across the 60 cell lines, which were shown to represent distinct mechanisms of action. Further transcriptome analysis revealed a biomarker, NADPH abundance, for predicting sensitivity to ferroptosis-inducing compounds, which we experimentally validated. In summary, incorporating cell-line selectivity filters improves the predictive power of pharmacogenomic analyses and enables discovery of biomarkers that predict the sensitivity of cells to specific cell death inducers. PMID:26853626

  8. Cell-Line Selectivity Improves the Predictive Power of Pharmacogenomic Analyses and Helps Identify NADPH as Biomarker for Ferroptosis Sensitivity.

    PubMed

    Shimada, Kenichi; Hayano, Miki; Pagano, Nen C; Stockwell, Brent R

    2016-02-18

    Precision medicine in oncology requires not only identification of cancer-associated mutations but also effective drugs for each cancer genotype, which is still a largely unsolved problem. One approach for the latter challenge has been large-scale testing of small molecules in genetically characterized cell lines. We hypothesized that compounds with high cell-line-selective lethality exhibited consistent results across such pharmacogenomic studies. We analyzed the compound sensitivity data of 6,259 lethal compounds from the NCI-60 project. A total of 2,565 cell-line-selective lethal compounds were identified and grouped into 18 clusters based on their median growth inhibitory GI50 profiles across the 60 cell lines, which were shown to represent distinct mechanisms of action. Further transcriptome analysis revealed a biomarker, NADPH abundance, for predicting sensitivity to ferroptosis-inducing compounds, which we experimentally validated. In summary, incorporating cell-line-selectivity filters improves the predictive power of pharmacogenomic analyses and enables discovery of biomarkers that predict the sensitivity of cells to specific cell death inducers.

  9. Health responses to a new high-voltage power line route: design of a quasi-experimental prospective field study in the Netherlands

    PubMed Central

    2014-01-01

    Background New high-voltage power transmission lines will be introduced due to increasing demand for reliable and renewable energy supplies. Some residents associate non-specific health complaints with exposure to electromagnetic fields from nearby power lines. This study protocol describes the design and rationale of a prospective study investigating whether the introduction of a new power line triggers health responses in residents living nearby. Methods/Design The study is designed as a quasi-experimental field study with two pretests during the construction of a new power line route, and two posttests after it has been put into operation. Key outcomes are self-reported non-specific somatic and cognitive health complaints, and attribution of these health complaints to a power line. The main determinant is proximity to the new power line route. One member of every household (n = 2379) residing in close proximity (0-500 meters) to the overhead parts of a new power line route in the Netherlands is invited to participate, as well as a sample of household members (n = 2382) residing farther away (500-2000 meters). Multilevel analysis will be employed to test whether an increase in key outcome measures is related to proximity to the line. Longitudinal structural equation models will be applied to test to what extent health responses are mediated by psychosocial health mechanisms and moderated by negative oriented personality traits. Discussion This is the first study to investigate health responses to a new power line route in a prospective manner. The results will provide theoretical insight into psychosocial mechanisms operating during the introduction of an environmental health risk, and may offer suggestions to policymakers and other stakeholders for minimizing adverse health responses when introducing new high-voltage power lines. PMID:24606914

  10. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-120 Hanford-Ostrander Corridor Maintenance

    SciTech Connect

    Hutchinson, Ken

    2003-02-10

    Vegetation Management for the Hanford-Ostrander Transmission Line Corridor from Tower 10/4 to Tower 17/2 + 770. The line is a 500kV Single Circuit Transmission Line having an easement width of 300 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor as referenced on the attached checklist. The work will include the performance of road maintenance and tower pad maintenance along the Hanford-Ostrander transmission line. Maintenance will be performed from Tower 10/1, close to Army Loop road near the northeast corner of 200 West Area of the Hanford Nuclear Reservation to the western edge of the Arid Lands Ecological Reserve (ALE) at Tower 17/2 + 700. Total distance of the work is approximately 7.5 miles. The planned work includes spraying with herbicides to minimize vegetation regrowth along the access roads and removing shrubs from within 50 feet of each transmission tower.

  11. The influence of lightning induced voltage on the distribution power line polymer insulators.

    PubMed

    Izadi, Mahdi; Abd Rahman, Muhammad Syahmi; Ab-Kadir, Mohd Zainal Abidin; Gomes, Chandima; Jasni, Jasronita; Hajikhani, Maryam

    2017-01-01

    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.

  12. The influence of lightning induced voltage on the distribution power line polymer insulators

    PubMed Central

    Ab-Kadir, Mohd Zainal Abidin; Gomes, Chandima; Jasni, Jasronita; Hajikhani, Maryam

    2017-01-01

    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance. PMID:28234930

  13. Use of Individual Flight Corridors to Avoid Vortex Wakes

    NASA Technical Reports Server (NTRS)

    Rossow, Vernon J.

    2001-01-01

    Vortex wakes of aircraft pose a hazard to following aircraft until the energetic parts of their flow fields have decayed to a harmless level. It is suggested here that in-trail spacings between aircraft can be significantly and safely reduced by designing an individual, vortex-free flight corridor for each aircraft. Because each aircraft will then have its own flight corridor, which is free of vortex wakes while in use by the assigned aircraft, the time intervals between aircraft operations can be safely reduced to the order of seconds. The productivity of airports can then be substantially increased. How large the offset distances between operational corridors need to be to have them vortex free, and how airports need to be changed to accommodate an individual flight-corridor process for landing and takeoff operations, are explored. Estimates are then made of the productivity of an individual flight-corridor system as a function of the in-trail time interval between operations for various values of wake decay time, runway width, and the velocity of a sidewind. The results confirm the need for short time intervals between aircraft operations if smaller offset distances and increased productivity are to be achieved.

  14. Identifying Corridors among Large Protected Areas in the United States

    PubMed Central

    Belote, R. Travis; Dietz, Matthew S.; McRae, Brad H.; Theobald, David M.; McClure, Meredith L.; Irwin, G. Hugh; McKinley, Peter S.; Gage, Josh A.; Aplet, Gregory H.

    2016-01-01

    Conservation scientists emphasize the importance of maintaining a connected network of protected areas to prevent ecosystems and populations from becoming isolated, reduce the risk of extinction, and ultimately sustain biodiversity. Keeping protected areas connected in a network is increasingly recognized as a conservation priority in the current era of rapid climate change. Models that identify suitable linkages between core areas have been used to prioritize potentially important corridors for maintaining functional connectivity. Here, we identify the most “natural” (i.e., least human-modified) corridors between large protected areas in the contiguous Unites States. We aggregated results from multiple connectivity models to develop a composite map of corridors reflecting agreement of models run under different assumptions about how human modification of land may influence connectivity. To identify which land units are most important for sustaining structural connectivity, we used the composite map of corridors to evaluate connectivity priorities in two ways: (1) among land units outside of our pool of large core protected areas and (2) among units administratively protected as Inventoried Roadless (IRAs) or Wilderness Study Areas (WSAs). Corridor values varied substantially among classes of “unprotected” non-core land units, and land units of high connectivity value and priority represent diverse ownerships and existing levels of protections. We provide a ranking of IRAs and WSAs that should be prioritized for additional protection to maintain minimal human modification. Our results provide a coarse-scale assessment of connectivity priorities for maintaining a connected network of protected areas. PMID:27104683

  15. Parametric entry corridors for lunar/Mars aerocapture missions

    NASA Technical Reports Server (NTRS)

    Ling, Lisa M.; Baseggio, Franco M.; Fuhry, Douglas P.

    1991-01-01

    Parametric atmospheric entry corridor data are presented for Earth and Mars aerocapture. Parameter ranges were dictated by the range of mission designs currently envisioned as possibilities for the Human Exploration Initiative (HEI). This data, while not providing a means for exhaustive evaluation of aerocapture performance, should prove to be a useful aid for preliminary mission design and evaluation. Entry corridors are expressed as ranges of allowable vacuum periapse altitude of the planetary approach hyperbolic orbit, with chart provided for conversion to an approximate flight path angle corridor at entry interface (125 km altitude). The corridor boundaries are defined by open-loop aerocapture trajectories which satisfy boundary constraints while utilizing the full aerodynamic control capability of the vehicle (i.e., full lift-up or full lift-down). Parameters examined were limited to those of greatest importance from an aerocapture performance standpoint, including the approach orbit hyperbolic excess velocity, the vehicle lift to drag ratio, maximum aerodynamic load factor limit, and the apoapse of the target orbit. The impact of the atmospheric density bias uncertainties are also included. The corridor data is presented in graphical format, and examples of the utilization of these graphs for mission design and evaluation are included.

  16. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having...

  17. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having...

  18. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having...

  19. A computerized on-line power loss testing system for the steel industry, based on the RCP compensation technique

    SciTech Connect

    Khanlou, A.; Moses, A.J.; Meydan, T.; Beckley, P.

    1995-11-01

    The design and development of a novel, non-enwrapping power loss testing system which can be used to grade electrical steels directly on the production line has been described. The developed system incorporates the use of Rogowski Chattock Potentiometer (RCP) coils. These coils function as a zero field potential indicator between two defined points along the measuring region of a single specimen of electrical steel, hence making the surface magnetic field proportional to the magnetizing current. This enables the field component necessary for power loss measurement to be obtained from the magnetizing current which is more convenient in an on-line situation. The developed system has been fully computerized and it is shown that under static laboratory conditions the system correlates well with a deviation of only 2.5% from values obtained using the current standard, the Epstein Frame. The effect of strip motion on the measurements has also been investigated and discussed to understand how the system will perform on the actual production line.

  20. Exploring the power of rice (O. sativa x O. rufipogon) chromosome segment substitution line libraries

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Transgressive variation was reported as an increase in grain yield for several rice (Oryza sativa x O. rufipogon) advanced backcross mapping populations. The objective of this study was to develop chromosome segment substitution line (CSSL) libraries to further dissect the reported transgressive var...

  1. Effects of landscape corridors on seed dispersal by birds.

    SciTech Connect

    Levey, Douglas, J.; Bolker, Benjamin M.; Tewksbury, Joshua J.; Sargent, Sarah; Haddad, Nick M.

    2005-07-01

    Levey, Douglas, J., Benjamin M. Bolker, Joshua J. Tewksbury, Sarah Sargent, and Nick M. Haddad. 2005. Effects of landscape corridors on seed dispersal by birds. Science 309:146-148. Abstract: Habitat fragmentation threatens biodiversity by disrupting dispersal. The mechanisms and consequences of this disruption are controversial, primarily because most organisms are difficult to track. We examined the effect of habitat corridors on long-distance dispersal of seeds by birds, and tested whether small-scale (G20 meters) movements of birds could be scaled up to predict dispersal of seeds across hundreds of meters in eight experimentally fragmented landscapes. A simulation model accurately predicted the observed pattern of seed rain and revealed that corridors functioned through edge following behavior of birds. Our study shows how models based on easily observed behaviors can be scaled up to predict landscape-level processes.

  2. Pen Branch stream corridor and Delta Wetlands change assessment

    SciTech Connect

    Blohm, J.D.

    1995-06-01

    Airborne multispectral scanner data from 1987 to 1991 covering the Pen Branch corridor and delta at SRS were utilized to provide a detailed change detection analysis. The multispectral data were geo-referenced to a Universal Transverse Mercator projection using finite element registration. Each year was then classified into eleven different landcover categories, and the yearly changes in each landcover category were analyzed. The decrease in operations of K Reactor in 1988 has resulted in drying of the corridor and delta. This has led to the decline of nonpersistent vegetation and the increase of persistent vegetation. Cattails, willow, and bottomland hardwoods, in particular, have grown to dominate the corridor and most of the delta.

  3. Fixed-Wing Micro Aerial Vehicle for Accurate Corridor Mapping

    NASA Astrophysics Data System (ADS)

    Rehak, M.; Skaloud, J.

    2015-08-01

    In this study we present a Micro Aerial Vehicle (MAV) equipped with precise position and attitude sensors that together with a pre-calibrated camera enables accurate corridor mapping. The design of the platform is based on widely available model components to which we integrate an open-source autopilot, customized mass-market camera and navigation sensors. We adapt the concepts of system calibration from larger mapping platforms to MAV and evaluate them practically for their achievable accuracy. We present case studies for accurate mapping without ground control points: first for a block configuration, later for a narrow corridor. We evaluate the mapping accuracy with respect to checkpoints and digital terrain model. We show that while it is possible to achieve pixel (3-5 cm) mapping accuracy in both cases, precise aerial position control is sufficient for block configuration, the precise position and attitude control is required for corridor mapping.

  4. Circuit for Communication over DC Power Line Using High Temperature Electronics

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor)

    2014-01-01

    A high temperature communications circuit includes a power conductor for concurrently conducting electrical energy for powering circuit components and transmitting a modulated data signal, and a demodulator for demodulating the data signal and generating a serial bit stream based on the data signal. The demodulator includes an absolute value amplifier for conditionally inverting or conditionally passing a signal applied to the absolute value amplifier. The absolute value amplifier utilizes no diodes to control the conditional inversion or passing of the signal applied to the absolute value amplifier.

  5. C IV and He II line emission of Lyman α blobs: powered by shock-heated gas

    NASA Astrophysics Data System (ADS)

    Cabot, Samuel; Cen, Renyue; Zheng, Zheng

    2017-01-01

    Utilizing ab initio ultrahigh resolution hydrodynamical simulations, we investigate the properties of the interstellar and circumgalactic medium of Lyα blobs (LABs) at z = 3, focusing on three important emission lines: Lyα 1216 Å, He II 1640 Å and C IV 1549 Å. Their relative strengths provide a powerful probe of the thermodynamic properties of the gas when confronted with observations. By adjusting the dust attenuation effect using one parameter and matching the observed size-luminosity relation of LABs using another parameter, we show that our simulations can reproduce the observed C IV/Lyα and He II/Lyα ratios adequately. This analysis provides the first successful physical model to account for simultaneously the LAB luminosity function, luminosity-size relation and the C IV/Lyα and He II/Lyα ratios, with only two parameters. The physical underpinning for this model is that, in addition to the stellar component for the Lyα emission, the Lyα and C IV emission lines due to shock-heated gas are primarily collisional excitation driven and the He II emission line collisional ionization driven. We find that the density, temperature and metallicity of the gas responsible for each emission line is significantly distinct, in a multiphase interstellar and circumgalactic medium that is shock heated primarily by supernovae and secondarily by gravitational accretion of gas.

  6. An Insight on Right of Way and its Cost for Power Transmission Cable and Conventional Overhead Transmission Lines

    NASA Astrophysics Data System (ADS)

    Khandelwal, P.; Pachori, A.; Khandelwal, T.

    2013-12-01

    This paper provides the complete information related to Right of Way (RoW) for the construction of new power transmission line (TL) in terms of present cost for overhead transmission line and underground XLPE transmission cable. The former part of the paper describes the general procedure and rules for acquisition of land for RoW by transmission asset owner (TAO) while in the later part the cost associated to acquire RoW and its impact on the cost of adjacent land have been detailed. It also discusses the actual dismantling cost including the cost of waste metal what TAO get after completion of lifecycle of TL due to increase in metal prices. In this paper cost of RoW after completion of lifecycle of TL is also highlighted. This paper compares the cost of RoW for overhead transmission line and underground XLPE transmission cable for construction of new TL. Also for old transmission infrastructure cost of RoW for change from overhead transmission line to underground XLPE transmission cable is detailed by application of replacement model.

  7. Finite time-Lyapunov based approach for robust adaptive control of wind-induced oscillations in power transmission lines

    NASA Astrophysics Data System (ADS)

    Ghabraei, Soheil; Moradi, Hamed; Vossoughi, Gholamreza

    2016-06-01

    Large amplitude oscillation of the power transmission lines, which is also known as galloping phenomenon, has hazardous consequences such as short circuiting and failure of transmission line. In this article, to suppress the undesirable vibrations of the transmission lines, first the governing equations of transmission line are derived via mode summation technique. Then, due to the occurrence of large amplitude vibrations, nonlinear quadratic and cubic terms are included in the derived linear equations. To suppress the vibrations, arbitrary number of the piezoelectric actuators is assumed to exert the actuation forces. Afterwards, a Lyapunov based approach is proposed for the robust adaptive suppression of the undesirable vibrations in the finite time. To compensate the supposed parametric uncertainties with unknown bands, proper adaption laws are introduced. To avoid the vibration devastating consequences as quickly as possible, appropriate control laws are designed. The vibration suppression in the finite time with supposed adaption and control laws is mathematically proved via Lyapunov finite time stability theory. Finally, to illustrate and validate the efficiency and robustness of the proposed finite time control scheme, a parametric case study with three piezoelectric actuators is performed. It is observed that the proposed active control strategy is more efficient and robust than the passive control methods.

  8. Spectroscopy of emission-line nebulae in powerful radio galaxies - Interpretation

    NASA Astrophysics Data System (ADS)

    Baum, S. A.; Heckman, T. M.; van Breugel, W.

    1992-04-01

    Long-slit optical spectra of the emission-line nebulae associated with 21 low-redshift (less than 0.2) radio galaxies are analyzed. Nebulae are classified kinematically into three types: rotators, calm nonrotators, and violent nonrotators; these types are characterized. It is proposed that the rotators have dynamically young disks of gas recently acquired by the radio galaxy in an interaction or merger with a gas-rich galaxy. This is consistent with the data on the morphologies, colors, and stellar dynamics of radio galaxies with strong emission lines. It is inferred from the association of the large-scale gas kinematics with the radio and optical properties of an active galaxy that the angular momentum of the gas which fuels the AGN may be an important parameter in the determinant of how activity is manifest in an AGN.

  9. Magnetic fields of high voltage power lines and risk of cancer in Finnish adults: nationwide cohort study.

    PubMed Central

    Verkasalo, P. K.; Pukkala, E.; Kaprio, J.; Heikkilä, K. V.; Koskenvuo, M.

    1996-01-01

    OBJECTIVE: To investigate the risk of cancer in association with magnetic fields in Finnish adults living close to high voltage power lines. DESIGN: Nationwide cohort study. SUBJECTS: 383,700 people who lived during 1970-89 within 500 metres of overhead power lines of 110-400 kV in a magnetic field calculated to be > or = 0.01 microT. Study subjects were identified by record linkages of nationwide registers. MAIN OUTCOME MEASURES: Numbers of observed and expected cases of cancer, standardised incidence ratios, and incidence rate ratios adjusted for sex, age, calendar year, and social class--for example, by continuous cumulative exposure per 1 microT year with 95% confidence intervals from multiplicative models for all cancers combined and 21 selected types. RESULTS: Altogether 8415 cases of cancer were observed (standardised incidence ratio 0.98; 95% confidence interval 0.96 to 1.00) in adults. All incidence rate ratios for both sexes combined were non-significant and between 0.91 and 1.11. Significant excesses were observed in multiple myeloma in men (incidence rate ratio 1.22) and in colon cancer in women (1.16). CONCLUSIONS: Typical residential magnetic fields generated by high voltage power lines do not seem to be related to the risk of overall cancer in adults. The previously suggested associations between extremely low frequency magnetic fields and tumours of the nervous system, lymphoma, and leukaemia in adults and breast cancer in women were not confirmed. PMID:8898595

  10. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having Civil... Code (ANSI C2), available from IEEE Service Center, 445 Hoes Lane, Piscataway, N.J. 08854....

  11. NEW APPROACHES: Stroboscopic measurement of the power-line frequency using a bicycle

    NASA Astrophysics Data System (ADS)

    Giordano, José Luis

    1997-07-01

    When certain rotating bodies are viewed in artificial light a stroboscopic efect can be observed that would not be seen in daylight. A simple analysis of this effect is presented here together with an experiment using a bicycle and a tachometer that allows students to determine the frequency of the mains electricity powering the light.

  12. Thomson Parabola Spectrometer: a powerful tool to get on-line plasma information

    SciTech Connect

    Altana, C.; Schillaci, F.; Anzalone, A.; Cirrone, G.A.P; Tudisco, S.; Lanzalone, G.; Muoio, A.

    2015-07-01

    In this contribution we report the results of an experimental measurement performed with a TPS developed at INFN-LNS within the ELIMED project, by means of a powerful and self-consistent technique as a diagnostic tool for the ionic acceleration study in laser-generated-plasmas. (authors)

  13. Development of (RE)BCO cables for HTS power transmission lines

    NASA Astrophysics Data System (ADS)

    Mukoyama, S.; Yagi, M.; Masuda, T.; Amemiya, N.; Ishiyama, A.; Kashima, N.; Nagaya, S.; Aoki, Y.; Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y.

    2009-10-01

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I c and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  14. Low-power integrated-circuit driver for ferrite-memory word lines

    NASA Technical Reports Server (NTRS)

    Katz, S.

    1970-01-01

    Composite circuit uses both n-p-n bipolar and p-channel MOS transistors /BIMOS/. The BIMOS driver provides 1/ ease of integrated circuit construction, 2/ low standby power consumption, 3/ bidirectional current pulses, and 4/ current-pulse amplitudes and rise times independent of active device parameters.

  15. Contact Line Instability of Gravity-Driven Flow of Power-Law Fluids.

    PubMed

    Hu, Bin; Kieweg, Sarah L

    2015-11-01

    The moving contact line of a thin fluid film can often corrugate into fingers, which is also known as a fingering instability. Although the fingering instability of Newtonian fluids has been studied extensively, there are few studies published on contact line fingering instability of non-Newtonian fluids. In particular, it is still unknown how shear-thinning rheological properties can affect the formation, growth, and shape of a contact line instability. Our previous study (Hu and Kieweg, 2012) showed a decreased capillary ridge formation for more shear-thinning fluids in a 2D model (i.e. 1D thin film spreading within the scope of lubrication theory). Those results motivated this study's hypothesis: more shear-thinning fluids should have suppressed finger growth and longer finger wavelength, and this should be evident in linear stability analysis (LSA) and 3D (i.e. 2D spreading) numerical simulations. In this study, we developed a LSA model for the gravity-driven flow of shear-thinning films, and carried out a parametric study to investigate the impact of shear-thinning on the growth rate of the emerging fingering pattern. A fully 3D model was also developed to compare and verify the LSA results using single perturbations, and to explore the result of multiple-mode, randomly imposed perturbations. Both the LSA and 3D numerical results confirmed that the contact line fingers grow faster for Newtonian fluids than the shear-thinning fluids on both vertical and inclined planes. In addition, both the LSA and 3D model indicated that the Newtonian fluids form fingers with shorter wavelengths than the shear-thinning fluids when the plane is inclined; no difference in the most unstable (i.e. emerging) wavelength was observed at vertical. This study also showed that the distance between emerging fingers was smaller on a vertical plane than on a less-inclined plane for shear-thinning fluids, as previously shown for Newtonian fluids. For the first time for shear

  16. Relationship Between Selected Strength and Power Assessments to Peak and Average Velocity of the Drive Block in Offensive Line Play.

    PubMed

    Jacobson, Bert H; Conchola, Eric C; Smith, Doug B; Akehi, Kazuma; Glass, Rob G

    2016-08-01

    Jacobson, BH, Conchola, EC, Smith, DB, Akehi, K, and Glass, RG. Relationship between selected strength and power assessments to peak and average velocity of the drive block in offensive line play. J Strength Cond Res 30(8): 2202-2205, 2016-Typical strength training for football includes the squat and power clean (PC) and routinely measured variables include 1 repetition maximum (1RM) squat and 1RM PC along with the vertical jump (VJ) for power. However, little research exists regarding the association between the strength exercises and velocity of an actual on-the-field performance. The purpose of this study was to investigate the relationship of peak velocity (PV) and average velocity (AV) of the offensive line drive block to 1RM squat, 1RM PC, the VJ, body mass (BM), and body composition. One repetition maximum assessments for the squat and PC were recorded along with VJ height, BM, and percent body fat. These data were correlated with PV and AV while performing the drive block. Peal velocity and AV were assessed using a Tendo Power and Speed Analyzer as the linemen fired, from a 3-point stance into a stationary blocking dummy. Pearson product analysis yielded significant (p ≤ 0.05) correlations between PV and AV and the VJ, the squat, and the PC. A significant inverse association was found for both PV and AV and body fat. These data help to confirm that the typical exercises recommended for American football linemen is positively associated with both PV and AV needed for the drive block effectiveness. It is recommended that these exercises remain the focus of a weight room protocol and that ancillary exercises be built around these exercises. Additionally, efforts to reduce body fat are recommended.

  17. Modelling and optimization of transient processes in line focusing power plants with single-phase heat transfer medium

    NASA Astrophysics Data System (ADS)

    Noureldin, K.; González-Escalada, L. M.; Hirsch, T.; Nouri, B.; Pitz-Paal, R.

    2016-05-01

    A large number of commercial and research line focusing solar power plants are in operation and under development. Such plants include parabolic trough collectors (PTC) or linear Fresnel using thermal oil or molten salt as the heat transfer medium (HTM). However, the continuously varying and dynamic solar condition represent a big challenge for the plant control in order to optimize its power production and to keep the operation safe. A better understanding of the behaviour of such power plants under transient conditions will help reduce defocusing instances, improve field control, and hence, increase the energy yield and confidence in this new technology. Computational methods are very powerful and cost-effective tools to gain such understanding. However, most simulation models described in literature assume equal mass flow distributions among the parallel loops in the field or totally decouple the flow and thermal conditions. In this paper, a new numerical model to simulate a whole solar field with single-phase HTM is described. The proposed model consists of a hydraulic part and a thermal part that are coupled to account for the effect of the thermal condition of the field on the flow distribution among the parallel loops. The model is specifically designed for large line-focusing solar fields offering a high degree of flexibility in terms of layout, condition of the mirrors, and spatially resolved DNI data. Moreover, the model results have been compared to other simulation tools, as well as experimental and plant data, and the results show very good agreement. The model can provide more precise data to the control algorithms to improve the plant control. In addition, short-term and accurate spatially discretized DNI forecasts can be used as input to predict the field behaviour in-advance. In this paper, the hydraulic and thermal parts, as well as the coupling procedure, are described and some validation results and results of simulating an example field are

  18. Joint terminals and relay optimization for two-way power line information exchange systems with QoS constraints

    NASA Astrophysics Data System (ADS)

    Wu, Xiaolin; Rong, Yue

    2015-12-01

    The quality-of-service (QoS) criteria (measured in terms of the minimum capacity requirement in this paper) are very important to practical indoor power line communication (PLC) applications as they greatly affect the user experience. With a two-way multicarrier relay configuration, in this paper we investigate the joint terminals and relay power optimization for the indoor broadband PLC environment, where the relay node works in the amplify-and-forward (AF) mode. As the QoS-constrained power allocation problem is highly non-convex, the globally optimal solution is computationally intractable to obtain. To overcome this challenge, we propose an alternating optimization (AO) method to decompose this problem into three convex/quasi-convex sub-problems. Simulation results demonstrate the fast convergence of the proposed algorithm under practical PLC channel conditions. Compared with the conventional bidirectional direct transmission (BDT) system, the relay-assisted two-way information exchange (R2WX) scheme can meet the same QoS requirement with less total power consumption.

  19. Impact of Line Width and Power of Laser on Radio over Fiber System

    NASA Astrophysics Data System (ADS)

    Sharma, Sakshi; Bhatia, Kamaljeet Singh; Kaur, Harsimrat

    2015-03-01

    In order to increase the capacity of the existing optical communication networks advanced modulation schemes are utilized. Keeping this in view, an radio-over-fiber subcarrier multiplexing (SCM) employing ASK modulation technique is proposed. Response of the system is analysed by varying the linewidth and the power of the CW Laser and the optimum value is concluded for the same so as to achieve reliable communication.

  20. The HEMP (high altitude electromagnetic pulse) response of an overhead power distribution line

    SciTech Connect

    Tesche, F.M.; Barnes, P.R.

    1988-01-01

    A study of the HEMP response of a realistic power distribution system was undertaken, and its results are described in this paper. This study involved the following elements: (1) the use of the new HEMP environment, (2) the use of a multiconductor coupling model, and (3) the measurement of the pulse response of an actual distribution transformer to permit the use of this data in the analysis.

  1. Low-quality habitat corridors as movement conduits for two butterfly species.

    SciTech Connect

    Haddad, Nick, M.; Tewksbury, Joshua, J.

    2005-01-01

    Haddad, Nick, M, and Joshua J. Tewksbury. Low-quality habitat corridors as movement conduits for two butterfly species. Ecol. Apps. 15(1):250-257. Abstract. Corridors are a primary conservation tool to increase connectivity, promote individual movement, and increase gene flow among populations in fragmented landscapes. The establishment of effective conservation corridors will depend on constructing or pre-serving connecting habitat that attracts dispersing individuals. Yet, it remains unclear whether corridors must necessarily be composed of high-quality habitat to be effective and promote dispersal and gene flow. We address this issue with two mobile, open-habitat butterfly species, Junonia coenia HuÈbner and Euptoieta claudia Cramer. Using experimental landscapes created explicitly to examine the effects of corridors on dispersal rates, we show that open-habitat corridors can serve as dispersal conduits even when corridors do not support resident butterfly populations. Both butterfly species were rare near forest edges and equally rare in narrow corridors, yet both species dispersed more often between patches connected by these corridors than between isolated patches. At least for species that can traverse corridors within a generation, corridor habitat may be lower in quality than larger patches and still increase dispersal and gene flow. For these species, abundance surveys may not accurately represent the conservation value of corridors.

  2. 14 CFR 93.305 - Flight-free zones and flight corridors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Flight Rules Area within the following flight-free zones: (a) Desert View Flight-free Zone. That airspace... west between the Desert View and Bright Angel Flight-free Zones, is designated the “Zuni Point Corridor... zone and the Desert View Flight-free Zone, is designated the “Zuni Point Corridor.” The corridor to...

  3. 14 CFR 93.305 - Flight-free zones and flight corridors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Flight Rules Area within the following flight-free zones: (a) Desert View Flight-free Zone. That airspace... west between the Desert View and Bright Angel Flight-free Zones, is designated the “Zuni Point Corridor... zone and the Desert View Flight-free Zone, is designated the “Zuni Point Corridor.” The corridor to...

  4. 14 CFR 93.305 - Flight-free zones and flight corridors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Flight Rules Area within the following flight-free zones: (a) Desert View Flight-free Zone. That airspace... west between the Desert View and Bright Angel Flight-free Zones, is designated the “Zuni Point Corridor... zone and the Desert View Flight-free Zone, is designated the “Zuni Point Corridor.” The corridor to...

  5. 14 CFR 93.305 - Flight-free zones and flight corridors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Flight Rules Area within the following flight-free zones: (a) Desert View Flight-free Zone. That airspace... west between the Desert View and Bright Angel Flight-free Zones, is designated the “Zuni Point Corridor... zone and the Desert View Flight-free Zone, is designated the “Zuni Point Corridor.” The corridor to...

  6. 14 CFR 93.305 - Flight-free zones and flight corridors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Flight Rules Area within the following flight-free zones: (a) Desert View Flight-free Zone. That airspace... west between the Desert View and Bright Angel Flight-free Zones, is designated the “Zuni Point Corridor... zone and the Desert View Flight-free Zone, is designated the “Zuni Point Corridor.” The corridor to...

  7. 78 FR 16036 - Service Level Environmental Impact Statement for the Texas Oklahoma Passenger Rail Study Corridor...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ... Rail Study (Study) also includes preparation of a service development plan for the corridor for each of... agency in the development of the EIS. The Service Level EIS will evaluate a reasonable range of corridor alternatives and make decisions regarding the preferred corridor, location of train service termini,...

  8. SULFUR REMOVAL FROM PIPE LINE NATURAL GAS FUEL: APPLICATION TO FUEL CELL POWER GENERATION SYSTEMS

    SciTech Connect

    King, David L.; Birnbaum, Jerome C.; Singh, Prabhakar

    2003-11-21

    Pipeline natural gas is being considered as the fuel of choice for utilization in fuel cell-based distributed generation systems because of its abundant supply and the existing supply infrastructure (1). For effective utilization in fuel cells, pipeline gas requires efficient removal of sulfur impurities (naturally occurring sulfur compounds or sulfur bearing odorants) to prevent the electrical performance degradation of the fuel cell system. Sulfur odorants such as thiols and sulfides are added to pipeline natural gas and to LPG to ensure safe handling during transportation and utilization. The odorants allow the detection of minute gas line leaks, thereby minimizing the potential for explosions or fires.

  9. Observations of power line harmonic radiation by the low-altitude AUREOL 3 satellite

    SciTech Connect

    Parrot, M.

    1994-03-01

    This paper presents observations of very low frequency radiation in the lower part of the ionosphere from a polar orbiting satellite at low latitudes. It was able to record several observation of low frequency radiation which is very close to a harmonic of the 50 Hz line frequency. The frequency is observed to drift in time, from 1 to 8 Hz/sec. They are not sure how to account for this apparent non-linear coupling of these very low frequency waves into the ionosphere.

  10. Dash line glass- and sapphire-cutting with high power USP laser

    NASA Astrophysics Data System (ADS)

    Mishchik, Konstantin; Chassagne, Bruno; Javaux-Léger, Clémentine; Hönninger, Clemens; Mottay, Eric; Kling, Rainer; Lopez, John

    2016-03-01

    Glass cutting is a subject of high interest for flat panel display and consumer electronics industries. Among laser-based, water jet-based and diamond tool-based existing solutions, ultra-short pulses (USP) appear as a promising technology since this laser technology has the unique capacity to produce highly localized bulk modification owing to non-linear absorption. The cutting using USP lasers could be performed either by full ablation which is slow and generates a lot of dust, by controlled fracture propagation which is slow as well and may lead to path deviation, by stealth dicing which produces rough sidewalls, or by self-breaking induced by in-volume laser irradiation. The laser treatment is often continuous which is not necessary to perform glass cutting and may lead to over-exposure. In this paper we report on single pass glass and sapphire cutting using an USP laser (20W @200kHz or 8W@2MHz) using dash line laser treatment along the cutting trajectory. In-volume energy deposition was done along the glass thickness owing to a Bessel beam. The results will be discussed in terms of sidewall profile and roughness, path deviation, rim sharpness, energy dose and feed rate. Dash line treatment enables to tune the energy deposition and to produce the cutting effect but with a narrower heat affected zone, a better sidewall quality and a more accurate trajectory control of the cutting path.

  11. Current densities and total contact currents for 110 and 220 kV power line tasks.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo

    2014-10-01

    The aim of this study was to analyze all values of electric current from measured periods while performing tasks on 110 and 220 kV power lines. Additionally, the objective was to study the average current densities and average total contact currents caused by electric fields in 110 and 220 kV power line tasks. One worker simulated the following tasks: (A) tested insulation voltage at a 110 kV portal tower, (B) checked the wooden towers for rot at a 110 kV portal tower, (C) tested insulation voltage at a 220 kV portal tower, and (D) checked the wooden towers for rot at a 220 kV portal tower. The highest average current density in the neck was 2.0 mA/m(2) (calculated internal electric field was 19.0-38.0 mV/m), and the highest average contact current was 234 µA. All measured values at 110 and 220 kV towers were lower than the basic restrictions (0.1 and 0.8 V/m) of the International Commission on Non-ionizing Radiation Protection.

  12. Childhood cancer and magnetic fields from high-voltage power lines in England and Wales: a case–control study

    PubMed Central

    Kroll, M E; Swanson, J; Vincent, T J; Draper, G J

    2010-01-01

    Background: Epidemiological evidence suggests that chronic low-intensity extremely-low-frequency magnetic-field exposure is associated with increased risk of childhood leukaemia; it is not certain the association is causal. Methods: We report a national case–control study relating childhood cancer risk to the average magnetic field from high-voltage overhead power lines at the child's home address at birth during the year of birth, estimated using National Grid records. From the National Registry of Childhood Tumours, we obtained records of 28 968 children born in England and Wales during 1962–1995 and diagnosed in Britain under age 15. We selected controls from birth registers, matching individually by sex, period of birth, and birth registration district. No participation by cases or controls was required. Results: The estimated relative risk for each 0.2 μT increase in magnetic field was 1.14 (95% confidence interval 0.57 to 2.32) for leukaemia, 0.80 (0.43–1.51) for CNS/brain tumours, and 1.34 (0.84–2.15) for other cancers. Conclusion: Although not statistically significant, the estimate for childhood leukaemia resembles results of comparable studies. Assuming causality, the estimated attributable risk is below one case per year. Magnetic-field exposure during the year of birth is unlikely to be the whole cause of the association with distance from overhead power lines that we previously reported. PMID:20877338

  13. Interior view of the northwest end corridor, showing doors and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view of the northwest end corridor, showing doors and barred openings to former fan and engine rooms (now garage) and entry to northwest gun chamber (labeled "Gun Turret No. One") - U.S. Naval Base, Pearl Harbor, Battery Adair, Princeton Place, Pearl City, Honolulu County, HI

  14. 25. Corridor between the Launch Control Center and the Launch ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Corridor between the Launch Control Center and the Launch Control Equipment Room, view from Launch Control Center. Thalheimer - Whiteman Air Force Base, Oscar O-1 Minuteman Missile Alert Facility, Southeast corner of Twelfth & Vendenberg Avenues, Knob Noster, Johnson County, MO

  15. Interior view, east to west corridor from the Fourteenth Street ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view, east to west corridor from the Fourteenth Street lobby to the Fifteenth Street side of the building (168' in length) - United States Department of Commerce, Bounded by Fourteenth, Fifteenth, and E streets and Constitution Avenue, Washington, District of Columbia, DC

  16. View looking north along the main corridor on the third ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking north along the main corridor on the third floor of the south wing. This view, before the damaged roof was removed, captures the manner in which the continuous roof monitor provided natural illumination and ventilation for the third-floor. - U. S. Naval Asylum, Biddle Hall, Gray's Ferry Avenue, Philadelphia, Philadelphia County, PA

  17. This image, looking south, shows a typical corridor in the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    This image, looking south, shows a typical corridor in the laboratory area of the building, where numerous pipes were required to carry the various utilities needed for procedure and safety equipment - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  18. 34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" ENTRANCE CORRIDOR LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  19. Interior view, secondstory passage extending westward from main corridor to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view, second-story passage extending westward from main corridor to rooms on the north side of the rotunda in the rotunda extension. The roof and third-floor in this area is completely missing. - U. S. Naval Asylum, Biddle Hall, Gray's Ferry Avenue, Philadelphia, Philadelphia County, PA

  20. Malaysia's Multimedia Super Corridor and Roles of Information Professionals.

    ERIC Educational Resources Information Center

    Reid, Edna

    In Malaysia, the government is supporting the diffusion of the Internet and is spearheading a project to bring Malaysia into the information age, by helping to design a smart city called the Multimedia Super Corridor (MSC). The MSC is being planned as a high-technology center where world-class multimedia companies can develop state-of-the-art…

  1. 51. BF corridor, (example of older building meeting with new ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. BF corridor, (example of older building meeting with new building addition) from outside room BF-6, basement level, building 500, looking south - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  2. 1. GENERAL SETTING; LOOKING SOUTHWEST INTO RAILROAD CORRIDOR; BUILDING 92 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL SETTING; LOOKING SOUTHWEST INTO RAILROAD CORRIDOR; BUILDING 92 IS PARTIALLY VISIBLE AT UPPER RIGHT; BUILDING 168 (1960 HOG KILL) AT LOWER LEFT - Rath Packing Company, Hog Dressing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA

  3. Interior view, secondfloor corridor looking east. Note the door to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view, second-floor corridor looking east. Note the door to Egyptian Hall in the center distance and the door to Gothic Hall on the eastern entresol (third floor) at the top of the stairs - Masonic Temple, 1 North Broad Street, Philadelphia, Philadelphia County, PA

  4. Vault Area (original section), east corridor, looking north, showing tops ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, looking north, showing tops of individual vaults and vent housings - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  5. Vault Area (original section), east corridor, Vault No. 5, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Vault Area (original section), east corridor, Vault No. 5, showing inner set of doors on vault - Fort McNair, Film Store House, Fort Lesley J. McNair, P Street between Third & Fourth Streets, Southwest, Washington, District of Columbia, DC

  6. 2. INTERIOR VIEW OF MAIN CORRIDOR, LOOKING SOUTHEAST; DOORS TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. INTERIOR VIEW OF MAIN CORRIDOR, LOOKING SOUTHEAST; DOORS TO HALLWAY LEADING TO HYDROTHERAPY ROOM, ELECTRIC LIGHT CABINETS AND DRESSING ROOM ON LEFT - Fort McCoy, Building No. T-1054, South side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  7. INTERIOR VIEW OF NARROW CORRIDOR. NOTE THE ENTRY STAIRWAY (STAIRS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF NARROW CORRIDOR. NOTE THE ENTRY STAIRWAY (STAIRS COVERED WITH EARTH) LEADING UP TO GROUND LEVEL ON THE LEFT. VIEW FACING WEST - U.S. Naval Base, Pearl Harbor, Ford Island 5-Inch Antiaircraft Battery, Battery Command Center, Ford Island, Pearl City, Honolulu County, HI

  8. INTERIOR VIEW OF THE CORRIDOR DOOR TO THE SOUTH ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF THE CORRIDOR DOOR TO THE SOUTH ROOM SHOWING THE STRAP HINGES AND LATCHES. VIEW FACING SOUTHWEST - U.S. Naval Base, Pearl Harbor, Ford Island 5-Inch Antiaircraft Battery, Battery Command Center, Ford Island, Pearl City, Honolulu County, HI

  9. 31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR AT MEZZANINE AND LOWER LEVELS. INEEL DRAWING NUMBER 200-0633-00-287-106352. FLUOR NUMBER 5775-CPP-633-A-2. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  10. 37. PLAN OF ACCESS CORRIDOR PIPING INCLUDES WASTE HOLD TANK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. PLAN OF ACCESS CORRIDOR PIPING INCLUDES WASTE HOLD TANK CELL, OFFGAS CELL, ADSORBER CELL, AND OFFGAS FILTER CELL. INEEL DRAWING NUMBER 200-0633-00-287-106453. FLUOR NUMBER 5775-CPP-P-58. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  11. 38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF NAVY GUN BARRELS. INEEL DRAWING NUMBER 200-0633-00-287-106454. FLUOR NUMBER 5775-CPP-633-P-59. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID

  12. 29. Basement under central corridor. Shaft on right actuates cross ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Basement under central corridor. Shaft on right actuates cross over valve. Shaft at left operates main flood valve to admit water into the bed. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  13. 15. View west of central corridor between filtration beds which ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. View west of central corridor between filtration beds which are located to the left and right of the photograph. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  14. 9. View northwest of east entry to central corridor between ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. View northwest of east entry to central corridor between the filtration beds. Note square chimney at right center of photograph which is a part of the Armory Street Pumping Station. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  15. 16. View west from center of central corridor between filtration ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. View west from center of central corridor between filtration beds which are located to the left and right of the photograph. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  16. 30. Valves under central corridor of filtration bed building. Main ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. Valves under central corridor of filtration bed building. Main flood valves is at left and crossover valve is a right. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  17. 45 CFR 153.530 - Risk corridors data requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Risk corridors data requirements. 153.530 Section... data requirements. (a) Premium data. A QHP issuer must submit to HHS data on the premiums earned with... of benefit and payment parameters. (b) Allowable costs. A QHP issuer must submit to HHS data on...

  18. 16. Control Area, Interconnecting Corridor, interior view showing highcapacity venting ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Control Area, Interconnecting Corridor, interior view showing high-capacity venting system and black-out shades on south wall VIEW WEST - NIKE Missile Battery PR-79, Control Area, Tucker Hollow Road south of State Route 101, Foster, Providence County, RI

  19. Interior view, ground floor passage crossing the main corridor at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view, ground floor passage crossing the main corridor at its center, looking east through the doorway linking the two perpendicular axes. The door at the end of the passage opens onto a passage running under the entrance portico bearing ground floor exterior doors at each end. - U. S. Naval Asylum, Biddle Hall, Gray's Ferry Avenue, Philadelphia, Philadelphia County, PA

  20. 33. Miter gears located on ceiling of central corridor of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. Miter gears located on ceiling of central corridor of filtration building. Gears allow valve wheels above to be offset from location of gate valve on pipes below. - Lake Whitney Water Filtration Plant, Filtration Plant, South side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT