Science.gov

Sample records for power loss distribution

  1. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  2. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  3. Measuring fiber connection loss using steady-state power distribution - A method

    NASA Astrophysics Data System (ADS)

    Daido, Y.; Miyauchi, E.; Iwama, T.

    1981-02-01

    This paper describes conditions for the reproducible measurement of optical fiber connection losses. The steady-state power distribution is characterized by the width of the far-field pattern (FFP). A method is proposed to determine the power distribution in the fiber from the measured FEP. Using this method, connection losses of graded-index fibers are calculated for various widths of the FFP. Calculated results are verified experimentally. The width of the FFP must be controlled to within an accuracy of 3% for a 0.05-dB reproducibility of the connection loss. Connection loss dependence on mismatch of fiber parameters is also calculated. Calculation shows that variations in core radius, numerical aperture, and index gradient have to be controlled to within 3%, 6%, and 0.3, respectively, for the same reproducibility.

  4. Influence of bending on power distribution in step-index plastic optical fibers and the calculation of bending loss.

    PubMed

    Kovacević, M S; Nikezić, D

    2006-09-10

    A means of calculating optical power distribution in bent multimode optical fibers is proposed. It employs the power-flow equation approximated by the Fokker-Planck equation that is solved by the explicit finite-difference method. Conceptually important steps of this procedure include (i) dividing the full length of the bent optical fiber into a finite number of short, straight segments; (ii) solving the power equation for each segment sequentially to find its output distribution; and (iii) expressing that output distribution in rotated coordinates of the subsequent segment along the curved fiber to determine the input distribution for that subsequent segment and thus enable the calculation of the power flow and output distribution for it. The segment length and bend-induced perturbation of output angles are determined by geometric optics. The resulting power distributions are given at different cross sections along the curved fiber axis. They vary with the radius of fiber curvature and launch conditions. Results are compared to those for straight fiber. Bending loss is calculated as well.

  5. Study on Power Loss Reduction Considering Load Variation with Large Penetration of Distributed Generation in Smart Grid

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Lv, Xiangyu; Guo, Li; Cai, Lixia; Jie, Jinxing; Su, Kuo

    2017-05-01

    With the increasing of penetration of distributed in the smart grid, the problems that the power loss increasing and short circuit capacity beyond the rated capicity of circuit breaker will become more serious. In this paper, a methodology (Modified BPSO) is presented for network reconfiguration which is based on hybrid approach of Tabu Search and BPSO algorithms to prevent the local convergence and to decrease the calculation time using double fitnesses to consider the constraints. Moreover, an average load simulated method (ALS method) load variation considered is proposed that the average load value is used to instead of the actual load to calculation. Finally, from a case study, the results of simulation certify the approaches will decrease drastically the losses and improve the voltage profiles obviously, at the same time, the short circuit capacity is also decreased into less the shut-off capacity of circuit breaker. The power losses won’t be increased too much even if the short circuit capacity constraint is considered; voltage profiles are better with the constraint of short circuit capacity considering. The ALS method is simple and calculated time is speed.

  6. A study using a Monte Carlo method of the optimal configuration of a distribution network in terms of power loss sensing.

    PubMed

    Moon, Hyun Ho; Lee, Jong Joo; Choi, Sang Yule; Cha, Jae Sang; Kang, Jang Mook; Kim, Jong Tae; Shin, Myong Chul

    2011-01-01

    the distribution loss associated with power distribution systems focus on sensing aspect and distributed power generation.

  7. Distribution network reconfiguration for energy loss reduction

    SciTech Connect

    Taleski, R.; Rajicic, D.

    1997-02-01

    A new method for energy loss reduction for distribution networks is presented. It is based on known techniques and algorithms for radial network analysis--oriented element ordering, power summation method for power flow, statistical representation of load variations, and a recently developed energy summation method for computation of energy losses. These methods, combined with the heuristic rules developed to lead the iterative process, make the energy loss minimization method effective, robust and fast. It presents an alternative to the power minimization methods for operation and planning purposes.

  8. Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2.

    SciTech Connect

    Dionne, B.; Tzanos, C. P.

    2011-05-23

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

  9. A Study Using a Monte Carlo Method of the Optimal Configuration of a Distribution Network in Terms of Power Loss Sensing

    PubMed Central

    Moon, Hyun Ho; Lee, Jong Joo; Choi, Sang Yule; Cha, Jae Sang; Kang, Jang Mook; Kim, Jong Tae; Shin, Myong Chul

    2011-01-01

    design, which considers the distribution loss associated with power distribution systems focus on sensing aspect and distributed power generation. PMID:22164047

  10. Exponentiated power Lindley distribution

    PubMed Central

    Ashour, Samir K.; Eltehiwy, Mahmoud A.

    2014-01-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data. PMID:26644927

  11. Exponentiated power Lindley distribution.

    PubMed

    Ashour, Samir K; Eltehiwy, Mahmoud A

    2015-11-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data.

  12. Power Scaling of the Size Distribution of Economic Loss and Fatalities due to Hurricanes, Earthquakes, Tornadoes, and Floods in the USA

    NASA Astrophysics Data System (ADS)

    Tebbens, S. F.; Barton, C. C.; Scott, B. E.

    2016-12-01

    Traditionally, the size of natural disaster events such as hurricanes, earthquakes, tornadoes, and floods is measured in terms of wind speed (m/sec), energy released (ergs), or discharge (m3/sec) rather than by economic loss or fatalities. Economic loss and fatalities from natural disasters result from the intersection of the human infrastructure and population with the size of the natural event. This study investigates the size versus cumulative number distribution of individual natural disaster events for several disaster types in the United States. Economic losses are adjusted for inflation to 2014 USD. The cumulative number divided by the time over which the data ranges for each disaster type is the basis for making probabilistic forecasts in terms of the number of events greater than a given size per year and, its inverse, return time. Such forecasts are of interest to insurers/re-insurers, meteorologists, seismologists, government planners, and response agencies. Plots of size versus cumulative number distributions per year for economic loss and fatalities are well fit by power scaling functions of the form p(x) = Cx-β; where, p(x) is the cumulative number of events with size equal to and greater than size x, C is a constant, the activity level, x is the event size, and β is the scaling exponent. Economic loss and fatalities due to hurricanes, earthquakes, tornadoes, and floods are well fit by power functions over one to five orders of magnitude in size. Economic losses for hurricanes and tornadoes have greater scaling exponents, β = 1.1 and 0.9 respectively, whereas earthquakes and floods have smaller scaling exponents, β = 0.4 and 0.6 respectively. Fatalities for tornadoes and floods have greater scaling exponents, β = 1.5 and 1.7 respectively, whereas hurricanes and earthquakes have smaller scaling exponents, β = 0.4 and 0.7 respectively. The scaling exponents can be used to make probabilistic forecasts for time windows ranging from 1 to 1000 years

  13. Power Aware Distributed Systems

    DTIC Science & Technology

    2004-01-01

    employment of codes developed for correction of doubled errors or interleaving can be useful in the considered case. 2.3.3.3 Differential QPSK 2.3.3.3.1...Electronics Center, Leuven, Belgium) on memory optimization techniques for turbo codes . Currently, he is pursuing his Ph.D. degree UCLA, focusing on...DISTRIBUTION UNLIMITED. 12b. DISTRIBUTION CODE 13. ABSTRACT (Maximum 200 Words) The goal of PADS was to study power aware management techniques

  14. Industrial power distribution

    SciTech Connect

    Sorrells, M.A.

    1990-01-01

    This paper is a broad overview of industrial power distribution. Primary focus will be on selection of the various low voltage components to achieve the end product. Emphasis will be on the use of national standards to ensure a safe and well designed installation.

  15. Optimal loss reduction of distribution networks

    SciTech Connect

    Glamocanin, V. )

    1990-08-01

    A new algorithm for network reconfiguration of power distribution systems is presented. An optimal loss reduction is accomplished to maintain acceptable voltage at customer loads as well as to assure sufficient conductor and substation current capacity to handle load requirements. The success of the algorithm depends directly upon the straightforward and highly-efficient solution of quadratic cost transshipment problem. The new algorithm, described in this paper, completely eliminates the need for matrix operations and executes all operations directly on graph of the distribution system.

  16. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Thomason, Cindy; Anderson, Paul M.; Martin, James A.

    1990-01-01

    Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

  17. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Ashworth, Barry; Riedesel, Joel; Myers, Chris; Miller, William; Jones, Ellen F.; Freeman, Kenneth; Walsh, Richard; Walls, Bryan K.; Weeks, David J.; Bechtel, Robert T.

    1992-01-01

    Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.

  18. SSP Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Lynch, Thomas H.; Roth, A. (Technical Monitor)

    2000-01-01

    Space Solar Power is a NASA program sponsored by Marshall Space Flight Center. The Paper presented here represents the architectural study of a large power management and distribution (PMAD) system. The PMAD supplies power to a microwave array for power beaming to an earth rectenna (Rectifier Antenna). The power is in the GW level.

  19. Dielectric loss against piezoelectric power harvesting

    NASA Astrophysics Data System (ADS)

    Liang, Junrui; Shu-Hung Chung, Henry; Liao, Wei-Hsin

    2014-09-01

    Piezoelectricity is one of the most popular electromechanical transduction mechanisms for constructing kinetic energy harvesting systems. When a standard energy harvesting (SEH) interface circuit, i.e., bridge rectifier plus filter capacitor, is utilized for collecting piezoelectric power, the previous literature showed that the power conversion can be well predicted without much consideration for the effect of dielectric loss. Yet, as the conversion power gets higher by adopting power-boosting interface circuits, such as synchronized switch harvesting on inductor (SSHI), the neglect of dielectric loss might give rise to deviation in harvested power estimation. Given the continuous progress on power-boosting interface circuits, the role of dielectric loss in practical piezoelectric energy harvesting (PEH) systems should receive attention with better evaluation. Based on the integrated equivalent impedance network model, this fast track communication provides a comprehensive study on the susceptibility of harvested power in PEH systems under different conditions. It shows that, dielectric loss always counteracts piezoelectric power harvesting by causing charge leakage across piezoelectric capacitance. In particular, taking corresponding ideal lossless cases as references, the counteractive effect might be aggravated under one of the five conditions: larger dielectric loss tangent, lower vibration frequency, further away from resonance, weaker electromechanical coupling, or using power-boosting interface circuit. These relationships are valuable for the study of PEH systems, as they not only help explain the role of dielectric loss in piezoelectric power harvesting, but also add complementary insights for material, structure, excitation, and circuit considerations towards holistic evaluation and design for practical PEH systems.

  20. The Unseen Power Loss: Stemming the Flow.

    ERIC Educational Resources Information Center

    Gillett, Raphael

    2002-01-01

    Outlined an estimate-substitution strategy for a test comparing two means and developed an expected-power formula for the test. Demonstrated that for empirically representative distributions of effect size in psychology, the expected power deficit is large. (SLD)

  1. power loss in SSPX

    NASA Astrophysics Data System (ADS)

    Stewart, T. L.; Romero-Talamas, C. A.; McLean, H. S.; Correll, D. L.

    2007-11-01

    An absolute calibration has been performed on each of the seven chords of the Hα diagnostic [Z. Wang, G.A. Wurden, C.W Barnes, et al., Rev. Sci. Instrum. 72, 1059 (2001)] at SSPX. Simple models are used to estimate the total power lost to Hα radiation throughout experimental shots. Using these models, high energy shots (Te > 500 eV) are compared to low energy shots.

  2. Distributed Space Solar Power

    NASA Technical Reports Server (NTRS)

    Fork, Richard L.

    2001-01-01

    The objective was to assess the feasibility of safely collecting solar power at geostationary orbit and delivering it to earth. A strategy which could harness a small fraction of the millions of gigawatts of sunlight passing near earth could adequately supply the power needs of earth and those of space exploration far into the future. Light collected and enhanced both spatially and temporally in space and beamed to earth provides probably the only practical means of safe and efficient delivery of this space solar power to earth. In particular, we analyzed the feasibility of delivering power to sites on earth at a comparable intensity, after conversion to a usable form, to existing power needs. Two major obstacles in the delivery of space solar power to earth are safety and the development of a source suitable for space. We focused our approach on: (1) identifying system requirements and designing a strategy satisfying current eye and skin safety requirements; and (2) identifying a concept for a potential space-based source for producing the enhanced light.

  3. Power management and distribution technology

    NASA Technical Reports Server (NTRS)

    Dickman, John Ellis

    1993-01-01

    Power management and distribution (PMAD) technology is discussed in the context of developing working systems for a piloted Mars nuclear electric propulsion (NEP) vehicle. The discussion is presented in vugraph form. The following topics are covered: applications and systems definitions; high performance components; the Civilian Space Technology Initiative (CSTI) high capacity power program; fiber optic sensors for power diagnostics; high temperature power electronics; 200 C baseplate electronics; high temperature component characterization; a high temperature coaxial transformer; and a silicon carbide mosfet.

  4. Passive Microwave Power Distribution Systems.

    DTIC Science & Technology

    wavelength by switching a reciprocal latching ferrite phase shifter in the stub, in response to termination of microwave power from one of the feed tubes....A standby microwave transmitter power amplifier tube is switched into a microwave power distribution system for a phased array in microseconds when...after the switching is completed, the switching being accomplished by changing electrical length of a quarter-wavelength waveguide stub to one-half

  5. Minimum loss power flow in hydro thermal electric power systems based on Kron's loss formula

    SciTech Connect

    Ravindranath, K.M.; El-Hawary, M.E.

    1989-01-01

    The authors discuss the formulation of the optimal minimum loss hydro-thermal power flow problem in electric power systems on the basis of Kron's loss formula as the objective function. Results of computational experience with a Newton's iterative implementation using two standard test systems. The conclusion is that it is extremely important to have an accurate loss model representation due to the potential errors as well as slow and difficult convergence behavior of the process.

  6. Power Law Distribution in Education

    NASA Astrophysics Data System (ADS)

    Gupta, Hari M.; Campanha, José R.; Prado, Fernando D.

    We studied the statistical distribution of candidate's performance which is measured through their marks in university entrance examination (Vestibular) of UNESP (Universidade Estadual Paulista) for years 1998, 1999, and 2000. All students are divided in three groups: Physical, Biological and Humanities. We paid special attention to the examination of Portuguese language which is common for all and examinations for the particular area. We observed long ubiquitous power law tails in Physical and Biological sciences. This indicate the presence of strong positive feedback in sciences. We are able to explain completely these statistical distributions through Gradually Truncated Power law distributions which we developed recently to explain statistical behavior of financial market. The statistical distribution in case of Portuguese language and humanities is close to normal distribution. We discuss the possible reason for this peculiar behavior.

  7. Loss Reduction on Adoption of High Voltage LT Less Distribution

    NASA Astrophysics Data System (ADS)

    Tiwari, Deepika; Adhikari, Nikhileshwar Prasad; Gupta, Amit; Bajpai, Santosh Kumar

    2016-06-01

    In India there is a need to improve the quality of the electricity distribution process which has increased varying from year to year. In distribution networks, the limiting factor to load carrying capacity is generally the voltage reduction. High voltage distribution system (HVDS) is one of the steps to reduce line losses in electrical distribution network. It helps to reduce the length of low tension (LT) lines and makes the power available close to the users. The high voltage power distribution system reduces the probability of power theft by hooking HVDS suggests an increase in installation of small capacity single-phase transformers in the network which again save considerable energy. This paper is compared to existing conventional low tension distribution network with HVDS. The paper gives a clear picture of reduction in distribution losses with adoption of HVDS system. Losses Reduction of 11 kV Feeder in Nuniya (India) with adoption of HVDS have been worked out/ quantified and benefits thereby in generating capacity have discussed.

  8. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2016-07-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  9. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2017-06-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  10. Line Loss Minimization of Loop Distribution Systems Using UPFC

    NASA Astrophysics Data System (ADS)

    Sayed, Mahmoud A.; Inayoshi, Nobuyuki; Takeshita, Takaharu; Ueda, Fukashi

    This paper presents an elaborated mathematical analysis of the line loss minimum conditions of loop distribution systems. In order to achieve these conditions, the Unified Power Flow Controller (UPFC), a typical Flexible AC Transmission Systems (FACTS) device that is capable of instantaneous control of transmission and distribution power flow, is used. For minimizing the total line loss of the loop distribution system, the authors propose two control schemes, the Line Inductance Compensation control and the Line Voltage Compensation control. These control schemes can be applied for controlling the UPFC in the loop distribution system according to the line parameters. The effectiveness of the proposed control schemes has been verified experimentally using a laboratory prototype in a 200V, 6kVA system.

  11. Loss of 115 kV Power

    SciTech Connect

    Smith, J.A.

    2001-08-22

    This report discusses the postulated loss of 115 kV power. Continuous electrical power to Savannah River Plant reactors is necessary to maintain water flow for heat removal and essential monitoring and control. Should power supplied to the plant 115 kV system from offsite be lost, on-site generation is sufficient to maintain all reactors in a safe shutdown mode for an indefinite period. Should on-site generators for the 115 kV grid also be lost, diesel-electric generators within each reactor building are also sufficient to maintain safe shutdown for a finite period. In all cases DC power for necessary monitoring and control would be available from battery systems with AC converter backup.

  12. Minimum loss reconfiguration of unbalanced distribution networks

    SciTech Connect

    Borozan, V.; Rajicic, D.; Ackovski, R.

    1997-01-01

    A heuristic method for determining the configuration with minimum resistive line losses for three-phase unbalanced distribution networks is described. This method is based on previous papers dealing with balanced network. Using a fast and reliable load flow solution technique and also, efficient algorithms for network elements inspection, so that methodology becomes capable to solve the challenging problem while still maintaining a high execution speed. A developed algorithm is applied on a practical distribution network. Performed analysis highlight the influence of load imbalances on a solution of minimum loss reconfiguration problem.

  13. Linguistic Model for Engine Power Loss

    DTIC Science & Technology

    2011-11-27

    model, engine power loss, intelligent diagnostics 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Public Release 18. NUMBER OF PAGES...module via a wireless interface that is compliant with the IEEE 802.15 protocol. The wireless personal area network is implemented using the ZigBee ... secure short range wireless communications link, or via a wired Ethernet port to a mobile device (e.g., another laptop computer authorized for CBM

  14. Wealth distribution on complex networks with losses

    NASA Astrophysics Data System (ADS)

    Wang, Fei; Fang, Weiguo

    2015-07-01

    Wealth distribution plays an important role in the field of econophysics. In this paper, this issue is investigated based on the Bouchaud and Mézard (BM) wealth distribution model by the method of complex networks in this paper. Previous reports usually assumed that wealth increased steadily or was transferred from one agent to another. However, wealth may be lost due to some natural disasters or incidents. Therefore, we introduce terms representing losses in the BM model to describe the economic behavior more precisely. We find that an anti-degree preference helps to create an equitable economic environment. The Gini coefficient of the wealth distribution is calculated, and an optimized preferential parameter is obtained for both the case with losses and the case without losses. For variable values of the parameter, the corresponding results are obtained and discussed. If network topologies are considered, we find that a homogeneous network prompts an equitable economic environment. Simulations prove that losses enlarge the rich-poor gap.

  15. ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

    SciTech Connect

    Tuffner, Francis K.; Singh, Ruchi

    2011-08-09

    Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

  16. High frequency power distribution system

    NASA Technical Reports Server (NTRS)

    Patel, Mikund R.

    1986-01-01

    The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

  17. High frequency power distribution system

    NASA Astrophysics Data System (ADS)

    Patel, Mikund R.

    1986-04-01

    The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

  18. Technology spin-off from space power automation to terrestrial electrical power distribution control and operation

    NASA Astrophysics Data System (ADS)

    Callis, C. T.; Broadwater, R. P.; Chandrasekaran, A.

    Areas which hold potential for technology spin-off from space power automation into terrestrial electrical power distribution control and automation are investigated. Areas touched upon include load management, loss reduction, trend analysis, energy storage, and fault diagnosis and analysis with expert systems. A brief overview of terrestrial electric power technology and automation in terrestrial distribution is provided. Power handling capabilities, hardware, loads, and goals of terrestrial and space systems are compared.

  19. Distributed Power Electronics for PV Systems (Presentation)

    SciTech Connect

    Deline, C.

    2011-12-01

    An overview of the benefits and applications of microinverters and DC power optimizers in residential systems. Some conclusions from this report are: (1) The impact of shade is greater than just the area of shade; (2) Additional mismatch losses include panel orientation, panel distribution, inverter voltage window, soiling; (3) Per-module devices can help increase performance, 4-12% or more depending on the system; (4) Value-added benefits (safety, monitoring, reduced design constraints) are helping their adoption; and (5) The residential market is growing rapidly. Efficiency increases, cost reductions are improving market acceptance. Panel integration will further reduce price and installation cost. Reliability remains an unknown.

  20. Space station power management and distribution

    NASA Technical Reports Server (NTRS)

    Teren, F.

    1985-01-01

    The power system architecture is presented by a series of schematics which illustrate the power management and distribution (PMAD) system at the component level, including converters, controllers, switchgear, rotary power transfer devices, power and data cables, remote power controllers, and load converters. Power distribution options, reference power management, and control strategy are also outlined. A summary of advanced development status and plans and an overview of system test plans are presented.

  1. Calculation method for line loss in 10kV distribution grid planning

    NASA Astrophysics Data System (ADS)

    Xiao, Ming-hui; Lin, Ling-xue; Liu, Si-yuan

    2017-01-01

    Distribution grid line loss index is an important indicator of running and managing a distribution grid. A general feature in distribution network is its difficulty in gathering data about structure and operation. Based on its feature, this paper proposed a method for calculating line loss in 10kV distribution grid from the perspective of planning. According to the characteristics of power consumption on different location of the feeder, line loss can be divided into three parts, including the main line loss, the loss of branch line and the loss of distribution transformer. The proposed method achieved quick calculation and component analysis. Distributed coefficient was calculated by analyzing different distributed situation of load on feeder and the equivalent loss power on main line was calculated. Branch line and distribution transformer were equivalent to a resistance located at the head of the line to match the real power consumption. With the data acquirement, accuracy can be improved. Finally, the example of different power supply zone was calculated based on the method. The comparison between the calculated results and technical guidelines of southern power grid indicated the components of the line loss and put forward solutions for loss reduction. The method proposed overcame disadvantage of strong dependence on complete and precise data, which fits for planning work.

  2. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect

    Chertkov, Michael; Turitsyn, Konstantin; Sulc, Petr; Backhaus, Scott

    2010-01-01

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  3. Flux-transfer losses in helically wound superconducting power cables

    SciTech Connect

    Clem, John R; Malozemoff, A P

    2013-06-25

    Minimization of ac losses is essential for economic operation of high-temperature superconductor (HTS) ac power cables. A favorable configuration for the phase conductor of such cables has two counter-wound layers of HTS tape-shaped wires lying next to each other and helically wound around a flexible cylindrical former. However, if magnetic materials such as magnetic substrates of the tapes lie between the two layers, or if the winding pitch angles are not opposite and essentially equal in magnitude to each other, current distributes unequally between the two layers. Then, if at some point in the ac cycle the current of either of the two layers exceeds its critical current, a large ac loss arises from the transfer of flux between the two layers. A detailed review of the formalism, and its application to the case of paramagnetic substrates including the calculation of this flux-transfer loss, is presented.

  4. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  5. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  6. RFQ Designs and Beam-Loss Distributions for IFMIF

    SciTech Connect

    Jameson, Robert A

    2007-01-01

    The IFMIF 125 mA cw 40 MeV accelerators will set an intensity record. Minimization of particle loss along the accelerator is a top-level requirement and requires sophisticated design intimately relating the accelerated beam and the accelerator structure. Such design technique, based on the space-charge physics of linear accelerators (linacs), is used in this report in the development of conceptual designs for the Radio-Frequency-Quadrupole (RFQ) section of the IFMIF accelerators. Design comparisons are given for the IFMIF CDR Equipartitioned RFQ, a CDR Alternative RFQ, and new IFMIF Post-CDR Equipartitioned RFQ designs. Design strategies are illustrated for combining several desirable characteristics, prioritized as minimum beam loss at energies above ~ 1 MeV, low rf power, low peak field, short length, high percentage of accelerated particles. The CDR design has ~0.073% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7,is 12.3 m long, and accelerates ~89.6% of the input beam. A new Post-CDR design has ~0.077% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7 and ~8 m length, and accelerates ~97% of the input beam. A complete background for the designs is given, and comparisons are made. Beam-loss distributions are used as input for nuclear physics simulations of radioactivity effects in the IFMIF accelerator hall, to give information for shielding, radiation safety and maintenance design. Beam-loss distributions resulting from a ~1M particle input distribution representative of the IFMIF ECR ion source are presented. The simulations reported were performed with a consistent family of codes. Relevant comparison with other codes has not been possible as their source code is not available. Certain differences have been noted but are not consistent over a broad range of designs and parameter range. The exact transmission found by any of these codes should be treated as indicative, as each has various sensitivities in

  7. Aggregate size distribution of the soil loss

    NASA Astrophysics Data System (ADS)

    Szabó, Judit Alexandra; Jakab, Gergely; Szabó, Boglárka; Józsa, Sándor; Szalai, Zoltán; Centeri, Csaba

    2016-04-01

    In agricultural areas the soil erosion and soil loss estimation is vital information in long-term planning. During the initial period of the erosion a part of the soil particles and aggregates get transportable and nutrients and organic matter could be transported due to the effect of water or wind. This preliminary phase was studied with laboratory-scale rainfall simulator. Developed surface crust and aggregate size composition of the runoff was examined in six different slope-roughness-moisture content combination of a Cambisol and a Regosol. The ratio of micro- and macro aggregates in the runoff indicate the stability of the aggregates and determine the transport capacity of the runoff. Both soil samples were taken from field where the water erosion is a potential hazard. During the experiment the whole amount of runoff and sediment was collected through sieve series to a bucket to separate the micro- and macro aggregates. In case of both samples the micro aggregates dominate in the runoff and the runoff rates are similar. Although the runoff of the Regosol - with dominant >1000μm macro aggregate content - contained almost nothing but <50μm sized micro aggregates. Meanwhile the runoff of the Cambisol - with more balanced micro and macro aggregate content - contained dominantly 50-250μm sized micro aggregates and in some case remarkable ratio 250-1000μm sized macro aggregates. This difference occurred because the samples are resistant against drop erosion differently. In case of both sample the selectivity of the erosion and substance matrix redistribution manifested in mineral crusts in the surface where the quartz deposited in place while the lighter organic matter transported with the sediment. The detachment of the aggregates and the redistribution of the particles highly effect on the aggregate composition of the runoff which is connected with the quality of the soil loss. So while the estimation of soil loss quantity is more or less is easy, measuring

  8. Fuel cells for distributed power generation

    NASA Astrophysics Data System (ADS)

    Tarman, Paul B.

    Deregulation has caused a major change in power distribution in the USA. Large central power stations are being and will continue to be replaced by smaller, distributed power generation sources of less than 20 kW. Fuel cells, specifically molten carbonate fuel cells (MCFCs), are best suited to serve this need. Small turbines cannot achieve the efficiency or environmental friendliness of MCFCs in this power range. This paper discusses the goals of M-C Power Corporation and the advantages of its IMHEX® MCFC technology. M-C Power's factory, demonstration testing program, and its market-entry power plant are also described, as are its commercialization strategy and schedule.

  9. Distributed Power System for Microsatellites

    DTIC Science & Technology

    2004-12-15

    bus voltage and output current and imple- ments a peak- power - tracking algorithm. Thus if an increase in current demand from the PWM DC- DC converter...the ring bus should be selected to directly power the satellite’s largest load. The solar array controller must have a peak- power - tracking algorithm to

  10. Mobile Centers For Secondary Power Distribution

    NASA Technical Reports Server (NTRS)

    Mears, Robert L.

    1990-01-01

    Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

  11. Mobile Centers For Secondary Power Distribution

    NASA Technical Reports Server (NTRS)

    Mears, Robert L.

    1990-01-01

    Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

  12. Voltage Control in Distribution Systems Considered Reactive Power Output Sharing

    NASA Astrophysics Data System (ADS)

    Oshiro, Masato; Senjyu, Tomonobu; Yona, Atsushi; Urasaki, Naomitsu; Funabashi, Toshihisa

    In recent years, distributed generation (DG) and renewable energy source (RES) are attracting special attention to distribution systems. Renewable energy such as photovoltaic (PV) system and wind turbine generator are used as a source of clean energy. However, the large amount of distributed generation causes voltage deviation beyond a statutory range in distribution systems. This paper proposes a methodology for voltage control by using inverters interfaced with DG and tap changing transformers. In the proposed method a one-day schedule of voltage references for the control devices are determined by an optimization technique based on predicted values of load demand and PV power generation. Furthermore, decided reactive power output according to the locally measurable voltage based on droop characteristic. Slope and base value on droop characteristic are selected by fuzzy control. The proposed method accomplishes improvement against voltage distribution considered the reactive power output sharing and reduction of distribution loss. The effectiveness of the proposed method is verified by using MATLAB®.

  13. Optimization of Power Distribution Networks in Megacities

    NASA Astrophysics Data System (ADS)

    Manusov, V. Z.; Matrenin, P. V.; Ahyoev, J. S.; Atabaeva, L. Sh

    2017-06-01

    The study deals with the problem of city electrical networks optimization in big towns and megacities to increase electrical energy quality and decrease real and active power losses in the networks as well as in domestic consumers. The optimization is carried out according to the location selection and separate reactive power source in 10 kW networks of Swarm Intelligence algorithms, in particular, of Particle Swarm one. The problem solution based on Particle Swarm algorithm is determined by variables being discrete quantities and, in addition, there are several local minimums (troughs) to be available for a global minimum to be found. It is proved that the city power supply system optimization is carried out by the additional reactive power source to be installed at consumers location reducing reactive power flow, thereby, ensuring increase of power supply system quality and decrease of power losses in city networks.

  14. Power dissipation and temperature distribution in piezoelectric ceramic slabs.

    PubMed

    Thomas, D; Ebenezer, D D; Srinivasan, Sivakumar M

    2010-10-01

    A method is presented to determine power dissipation in one-dimensional piezoelectric slabs with internal losses and the resulting temperature distribution. The length of the slab is much greater than the lateral dimensions. Losses are represented using complex piezoelectric coefficients. It is shown that the spatially non-uniform power dissipation density in the slab can be determined by considering either hysteresis loops or the Poynting vector. The total power dissipated in the slab is obtained by integrating the power dissipation density over the slab and is shown to be equal to the power input to the slab for special cases of mechanically and electrically excited slabs. The one-dimensional heat equation that includes the effect of conduction and convection, and the boundary conditions, are then used to determine the temperature distribution. When the analytical expression for the power dissipation density is simple, direct integration is used. It is shown that a modified Fourier series approach yields the same results. For other cases, the temperature distribution is determined using only the latter approach. Numerical results are presented to illustrate the effects of internal losses, heat conduction and convection coefficients, and boundary conditions on the temperature distribution.

  15. Space Station Freedom power management and distribution design status

    NASA Technical Reports Server (NTRS)

    Javidi, S.; Gholdston, E.; Stroh, P.

    1989-01-01

    The design status of the power management and distribution electric power system for the Space Station Freedom is presented. The current design is a star architecture, which has been found to be the best approach for meeting the requirement to deliver 120 V dc to the user interface. The architecture minimizes mass and power losses while improving element-to-element isolation and system flexibility. The design is partitioned into three elements: energy collection, storage and conversion, system protection and distribution, and management and control.

  16. Voltage Regulation and Line Loss Minimization of Loop Distribution Systems Using UPFC

    NASA Astrophysics Data System (ADS)

    Sayed, Mahmoud A.; Takeshita, Takaharu

    This paper presents a new method for achieving line loss minimization and voltage regulation in the loop distribution systems, simultaneously. First, mathematical analysis of the line loss minimum conditions in the loop distribution systems is presented. Then, load voltage regulation is applied in the loop distribution system under line loss minimum condition. Reference angle of the desired load voltage is the main factor that can be used to minimize total line loss during load voltage control. In order to achieve these two objectives simultaneously, the UPFC (unified power flow controller), a typical FACTS (flexible AC transmission systems) device, that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the UPFC control scheme to regulate the load voltage under line loss minimization is presented. The effectiveness of the proposed control scheme has been verified experimentally using laboratory prototype in a 200V, 6kVA system.

  17. Loss distribution of systemic defaults in different interbank networks

    NASA Astrophysics Data System (ADS)

    Li, Shouwei; He, Jianmin

    2016-04-01

    We analyze the impact of the network structure, the default probability and the loss given default (LGD) on the loss distribution of systemic defaults in the interbank market, where network structures analyzed include random networks, small-world networks and scale-free networks. We find that the network structure has little effect on the shape of the loss distribution, whereas the opposite is true to the default probability; the LGD changes the shape of the loss distribution significantly when default probabilities are high; the maximum of the possible loss is sensitive to the network structure and the LGD.

  18. Solar power generation and distribution

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The production of electricity from solar energy is discussed. The economics of the proposed generation and distribution systems are analyzed. The use of photovoltaics for converting solar energy to home heating is proposed. The problems of energy distribution are analyzed from the standpoint of equipment costs and complexity.

  19. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1989-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  20. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1987-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  1. Convective contributions to local power loss in a Bumpy Torus

    SciTech Connect

    Hiroe, S.; Haste, G.R. Jr.; Tolliver, J.S.; Quon, B.H.; Goyer, J.R.; Solensten, L.; Conner, K.A.

    1986-12-01

    Power flow in the ELMO Bumpy Torus (Plasma Physics and Controlled Nuclear Fusion Research (Tokyo, 1974) (IAEA, Vienna, 1975) Vol. 2, p. 141; Plasma Phys. 25, 597 (1983)) was investigated by measuring the power received by a limiter. Selective removal of heating power from various cavities, including the cavity with the limiter, has demonstrated that the majority of the power is lost locally. Observations of the potential structure demonstrate that asymmetric potential contours are present which can lead to enhanced plasma loss.

  2. Distributed photovoltaic generation in residential distribution systems: Impacts on power quality and anti-islanding

    NASA Astrophysics Data System (ADS)

    Mitra, Parag

    The past few decades have seen a consistent growth of distributed PV sources. Distributed PV, like other DG sources, can be located at or near load centers and provide benefits which traditional generation may lack. However, distribution systems were not designed to accommodate such power generation sources as these sources might lead to operational as well as power quality issues. A high penetration of distributed PV resources may lead to bi-directional power flow resulting in voltage swells, increased losses and overloading of conductors. Voltage unbalance is a concern in distribution systems and the effect of single-phase residential PV systems on voltage unbalance needs to be explored. Furthermore, the islanding of DGs presents a technical hurdle towards the seamless integration of DG sources with the electricity grid. The work done in this thesis explores two important aspects of grid inte-gration of distributed PV generation, namely, the impact on power quality and anti-islanding. A test distribution system, representing a realistic distribution feeder in Arizona is modeled to study both the aforementioned aspects. The im-pact of distributed PV on voltage profile, voltage unbalance and distribution sys-tem primary losses are studied using CYMDIST. Furthermore, a PSCAD model of the inverter with anti-island controls is developed and the efficacy of the anti-islanding techniques is studied. Based on the simulations, generalized conclusions are drawn and the problems/benefits are elucidated.

  3. Computer Power: Part 1: Distribution of Power (and Communications).

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1988-01-01

    Discussion of the distribution of power to personal computers and computer terminals addresses options such as extension cords, perimeter raceways, and interior raceways. Sidebars explain: (1) the National Electrical Code; (2) volts, amps, and watts; (3) transformers, circuit breakers, and circuits; and (4) power vs. data wiring. (MES)

  4. Computer Power: Part 1: Distribution of Power (and Communications).

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1988-01-01

    Discussion of the distribution of power to personal computers and computer terminals addresses options such as extension cords, perimeter raceways, and interior raceways. Sidebars explain: (1) the National Electrical Code; (2) volts, amps, and watts; (3) transformers, circuit breakers, and circuits; and (4) power vs. data wiring. (MES)

  5. Distribution-Agnostic Stochastic Optimal Power Flow for Distribution Grids

    SciTech Connect

    Baker, Kyri; Dall'Anese, Emiliano; Summers, Tyler

    2016-11-21

    This paper outlines a data-driven, distributionally robust approach to solve chance-constrained AC optimal power flow problems in distribution networks. Uncertain forecasts for loads and power generated by photovoltaic (PV) systems are considered, with the goal of minimizing PV curtailment while meeting power flow and voltage regulation constraints. A data- driven approach is utilized to develop a distributionally robust conservative convex approximation of the chance-constraints; particularly, the mean and covariance matrix of the forecast errors are updated online, and leveraged to enforce voltage regulation with predetermined probability via Chebyshev-based bounds. By combining an accurate linear approximation of the AC power flow equations with the distributionally robust chance constraint reformulation, the resulting optimization problem becomes convex and computationally tractable.

  6. Power losses and the efficiency of industrially used gearboxes

    NASA Astrophysics Data System (ADS)

    Čarnogurská, Mária; Příhoda, Miroslav; Širillová, Ľubomíra

    2014-08-01

    This article gives the methodology for stating power losses and the efficiency of a gearbox working in natural cooling using dimensional analysis. The methodology reflects experimental research which investigated the effect of a change in revolutions and loading the gearbox on power losses. At the same time, it describes the conditions under which the proposed method may be applied for industrial, helical bevel geared motors.

  7. Fundamental rate-loss tradeoff for optical quantum key distribution

    NASA Astrophysics Data System (ADS)

    Takeoka, Masahiro; Guha, Saikat; Wilde, Mark M.

    2014-10-01

    Since 1984, various optical quantum key distribution (QKD) protocols have been proposed and examined. In all of them, the rate of secret key generation decays exponentially with distance. A natural and fundamental question is then whether there are yet-to-be discovered optical QKD protocols (without quantum repeaters) that could circumvent this rate-distance tradeoff. This paper provides a major step towards answering this question. Here we show that the secret key agreement capacity of a lossy and noisy optical channel assisted by unlimited two-way public classical communication is limited by an upper bound that is solely a function of the channel loss, regardless of how much optical power the protocol may use. Our result has major implications for understanding the secret key agreement capacity of optical channels—a long-standing open problem in optical quantum information theory—and strongly suggests a real need for quantum repeaters to perform QKD at high rates over long distances.

  8. Expert System Detects Power-Distribution Faults

    NASA Technical Reports Server (NTRS)

    Walters, Jerry L.; Quinn, Todd M.

    1994-01-01

    Autonomous Power Expert (APEX) computer program is prototype expert-system program detecting faults in electrical-power-distribution system. Assists human operators in diagnosing faults and deciding what adjustments or repairs needed for immediate recovery from faults or for maintenance to correct initially nonthreatening conditions that could develop into faults. Written in Lisp.

  9. Space Solar Power Management and Distribution (PMAD)

    NASA Technical Reports Server (NTRS)

    Lynch, Thomas H.

    2000-01-01

    This paper presents, in viewgraph form, SSP PMAD (Space Solar Power Management and Distribution). The topics include: 1) Architecture; 2) Backside Thermal View; 3) Solar Array Interface; 4) Transformer design and risks; 5) Twelve phase rectifier; 6) Antenna (80V) Converters; 7) Distribution Cables; 8) Weight Analysis; and 9) PMAD Summary.

  10. Assessment of distributed wind-power systems. Final report

    SciTech Connect

    Kaupang, B.M.

    1983-02-01

    A utility-oriented methodology for the purpose of evaluating distributed wind-power systems was developed and tested, utilizing data from three actual utility systems. Conventional utility planning techniques were used, including loss-of-load probability and production-cost-simulation methods in the generation planning area, transmission and distribution (T and D) system expansion models, and loss calculations. Evaluations were based on comparison of total utility-system cost with an without wind-power plants, and wre expressed in terms of wind-power-plant value and cost. Value is measured by the worth of displaced energy and capacity of conventional power plants, of T and D equipmen deferrals, and of T and D loss savings. Cost consists of he capital, and operating and maintenace costs of the wind-power plants. The value of distributed wind-power generation was found to be dominated by the generation energy and capacity value, as opposed to T and D system impacts. The energy value alone did, in two of the three utilities studied, result in a favorable value/cost relationship for the cost assumptions that were used. The problem of voltage fluctuation on distribution feeders from wind turbines due to wind gusts was studied for several sites. In most relaistic applications, the voltage fluctuations would not be a limiting criterion for practical wind-turbine penetration levels. If the wind turbine is connected to the distributionfeeder through a rectifier-inverter, voltage fluctuations become a negligible factor. However, reactive-power compensation of the inverter would most likely be required for this application.

  11. Cathode power distribution system and method of using the same for power distribution

    DOEpatents

    Williamson, Mark A; Wiedmeyer, Stanley G; Koehl, Eugene R; Bailey, James L; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2014-11-11

    Embodiments include a cathode power distribution system and/or method of using the same for power distribution. The cathode power distribution system includes a plurality of cathode assemblies. Each cathode assembly of the plurality of cathode assemblies includes a plurality of cathode rods. The system also includes a plurality of bus bars configured to distribute current to each of the plurality of cathode assemblies. The plurality of bus bars include a first bus bar configured to distribute the current to first ends of the plurality of cathode assemblies and a second bus bar configured to distribute the current to second ends of the plurality of cathode assemblies.

  12. Intelligent Systems for Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Button, Robert M.

    2002-01-01

    The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

  13. Intelligent Systems for Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Button, Robert M.

    2002-01-01

    The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

  14. Hierarchical distributed stabilization of power networks

    NASA Astrophysics Data System (ADS)

    Ishizaki, Takayuki; Sadamoto, Tomonori; Imura, Jun-ichi

    2014-10-01

    Large fluctuation of electric power due to high penetration of renewable energy sources such as photovoltaic and wind power generation increases the risk to make the whole power network system unstable. The conventional frequency control called load frequency control is based on PID (proportional-integral-derivative) control or more advanced centralized and decentralized/distributed control. If we could more effectively use information on the state of the other neighbor generators, we can expect to make the whole system more robust against the large frequency fluctuation. This paper proposes a fundamental framework towards the design of hierarchical distributed stabilizing controllers for a network of power generators and loads. This novel type of distributed controller, composed of a global controller and a set of local controllers, takes into account the effect of the interaction among the generators and loads to improve robustness for the variation of locally stabilizing controllers.

  15. Analytic saddlepoint approximation for ionization energy loss distributions

    NASA Astrophysics Data System (ADS)

    Sjue, S. K. L.; George, R. N.; Mathews, D. G.

    2017-09-01

    We present a saddlepoint approximation for ionization energy loss distributions, valid for arbitrary relativistic velocities of the incident particle 0 < v / c < 1 , provided that ionizing collisions are still the dominant energy loss mechanism. We derive a closed form solution closely related to Moyal's distribution. This distribution is intended for use in simulations with relatively low computational overhead. The approximation generally reproduces the Vavilov most probable energy loss and full width at half maximum to better than 1% and 10%, respectively, with significantly better agreement as Vavilov's κ approaches 1.

  16. Power fluctuation and power loss of wind turbines due to wind shear and tower shadow

    NASA Astrophysics Data System (ADS)

    Wen, Binrong; Wei, Sha; Wei, Kexiang; Yang, Wenxian; Peng, Zhike; Chu, Fulei

    2017-09-01

    The magnitude and stability of power output are two key indices of wind turbines. This study investigates the effects of wind shear and tower shadow on power output in terms of power fluctuation and power loss to estimate the capacity and quality of the power generated by a wind turbine. First, wind speed models, particularly the wind shear model and the tower shadow model, are described in detail. The widely accepted tower shadow model is modified in view of the cone-shaped towers of modern large-scale wind turbines. Power fluctuation and power loss due to wind shear and tower shadow are analyzed by performing theoretical calculations and case analysis within the framework of a modified version of blade element momentum theory. Results indicate that power fluctuation is mainly caused by tower shadow, whereas power loss is primarily induced by wind shear. Under steady wind conditions, power loss can be divided into wind farm loss and rotor loss. Wind farm loss is constant at 3 α(3 α-1) R 2/(8 H 2). By contrast, rotor loss is strongly influenced by the wind turbine control strategies and wind speed. That is, when the wind speed is measured in a region where a variable-speed controller works, the rotor loss stabilizes around zero, but when the wind speed is measured in a region where the blade pitch controller works, the rotor loss increases as the wind speed intensifies. The results of this study can serve as a reference for accurate power estimation and strategy development to mitigate the fluctuations in aerodynamic loads and power output due to wind shear and tower shadow.

  17. Power fluctuation and power loss of wind turbines due to wind shear and tower shadow

    NASA Astrophysics Data System (ADS)

    Wen, Binrong; Wei, Sha; Wei, Kexiang; Yang, Wenxian; Peng, Zhike; Chu, Fulei

    2017-05-01

    The magnitude and stability of power output are two key indices of wind turbines. This study investigates the effects of wind shear and tower shadow on power output in terms of power fluctuation and power loss to estimate the capacity and quality of the power generated by a wind turbine. First, wind speed models, particularly the wind shear model and the tower shadow model, are described in detail. The widely accepted tower shadow model is modified in view of the cone-shaped towers of modern large-scale wind turbines. Power fluctuation and power loss due to wind shear and tower shadow are analyzed by performing theoretical calculations and case analysis within the framework of a modified version of blade element momentum theory. Results indicate that power fluctuation is mainly caused by tower shadow, whereas power loss is primarily induced by wind shear. Under steady wind conditions, power loss can be divided into wind farm loss and rotor loss. Wind farm loss is constant at 3α(3α-1)R 2/(8H 2). By contrast, rotor loss is strongly influenced by the wind turbine control strategies and wind speed. That is, when the wind speed is measured in a region where a variable-speed controller works, the rotor loss stabilizes around zero, but when the wind speed is measured in a region where the blade pitch controller works, the rotor loss increases as the wind speed intensifies. The results of this study can serve as a reference for accurate power estimation and strategy development to mitigate the fluctuations in aerodynamic loads and power output due to wind shear and tower shadow.

  18. Study of the longitudinal distribution of power generated in a random distributed feedback Raman fibre laser with unidirectional pumping

    SciTech Connect

    Churkin, D V; El-Taher, A E; Vatnik, I D; Babin, Sergei A

    2012-09-30

    The longitudinal distribution of the Stokes-component power in a Raman fibre laser with a random distributed feedback and unidirectional pumping is measured. The fibre parameters (linear loss and Rayleigh backscattering coefficient) are calculated based on the distributions obtained. A numerical model is developed to describe the lasing power distribution. The simulation results are in good agreement with the experimental data. (optical fibres, lasers and amplifiers. properties and applications)

  19. Grid-connected distributed solar power systems

    NASA Astrophysics Data System (ADS)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  20. Vibration Monitoring of Power Distribution Poles

    SciTech Connect

    Clark Scott; Gail Heath; John Svoboda

    2006-04-01

    Some of the most visible and least monitored elements of our national security infrastructure are the poles and towers used for the distribution of our nation’s electrical power. Issues surrounding these elements within the United States include safety such as unauthorized climbing and access, vandalism such as nut/bolt removal or destructive small arms fire, and major vandalism such as the downing of power poles and towers by the cutting of the poles with a chainsaw or torches. The Idaho National Laboratory (INL) has an ongoing research program working to develop inexpensive and sensitive sensor platforms for the monitoring and characterization of damage to the power distribution infrastructure. This presentation covers the results from the instrumentation of a variety of power poles and wires with geophone assemblies and the recording of vibration data when power poles were subjected to a variety of stimuli. Initial results indicate that, for the majority of attacks against power poles, the resulting signal can be seen not only on the targeted pole but on sensors several poles away in the distribution network and a distributed sensor system can be used to monitor remote and critical structures.

  1. Single-phase ac losses in prototype HTS conductors for superconducting power transmission lines

    SciTech Connect

    Daney, D.E.; Maley, M.P.; Boenig, H.J.; Willis, J.O.; Coulter, J.Y.; Gherardi, L.; Coletta, G.

    1998-12-01

    The authors report single-phase ac loss measurements on 8, 4, and 3-layer, multi-strand, HTS prototype conductors for power transmission lines. They use both calorimetric and electrical techniques. The agreement between the two techniques suggests that the interlayer current distribution in one-meter long conductors are representative of those in long conductors. The losses for the 8 and 4-layer conductors are in rough agreement, with the 8-layer losses being somewhat lower. The 3-layer conductor losses are substantially higher--probably due to unbalanced azimuthal currents for this configuration.

  2. Forecasting photovoltaic array power production subject to mismatch losses

    SciTech Connect

    Picault, D.; Raison, B.; Bacha, S.; de la Casa, J.; Aguilera, J.

    2010-07-15

    The development of photovoltaic (PV) energy throughout the world this last decade has brought to light the presence of module mismatch losses in most PV applications. Such power losses, mainly occasioned by partial shading of arrays and differences in PV modules, can be reduced by changing module interconnections of a solar array. This paper presents a novel method to forecast existing PV array production in diverse environmental conditions. In this approach, field measurement data is used to identify module parameters once and for all. The proposed method simulates PV arrays with adaptable module interconnection schemes in order to reduce mismatch losses. The model has been validated by experimental results taken on a 2.2 kW{sub p} plant, with three different interconnection schemes, which show reliable power production forecast precision in both partially shaded and normal operating conditions. Field measurements show interest in using alternative plant configurations in PV systems for decreasing module mismatch losses. (author)

  3. Power distribution studies for CMS forward tracker

    SciTech Connect

    Todri, A.; Turqueti, M.; Rivera, R.; Kwan, S.; /Fermilab

    2009-01-01

    The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory is carrying out R&D investigations for the upgrade of the power distribution system of the Compact Muon Solenoid (CMS) Pixel Tracker at the Large Hadron Collider (LHC). Among the goals of this effort is that of analyzing the feasibility of alternative powering schemes for the forward tracker, including DC to DC voltage conversion techniques using commercially available and custom switching regulator circuits. Tests of these approaches are performed using the PSI46 pixel readout chip currently in use at the CMS Tracker. Performance measures of the detector electronics will include pixel noise and threshold dispersion results. Issues related to susceptibility to switching noise will be studied and presented. In this paper, we describe the current power distribution network of the CMS Tracker, study the implications of the proposed upgrade with DC-DC converters powering scheme and perform noise susceptibility analysis.

  4. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, R.F.

    1998-12-08

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in US Patent No. 5,495,221 entitled ``Dynamically Stable Magnetic Suspension/Bearing System.`` The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity. 8 figs.

  5. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, Richard F.

    1998-01-01

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in U.S. Patent No. 5,495,221 entitled "Dynamically Stable Magnetic Suspension/Bearing System." The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity.

  6. Inverter design for high frequency power distribution

    NASA Technical Reports Server (NTRS)

    King, R. J.

    1985-01-01

    A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.

  7. Galileo spacecraft power management and distribution system

    NASA Technical Reports Server (NTRS)

    Detwiler, R. C.; Smith, R. L.

    1990-01-01

    The Galileo PMAD (power management and distribution system) is described, and the design drivers that established the final as-built hardware are discussed. The spacecraft is powered by two general-purpose heat-source-radioisotope thermoelectric generators. Power bus regulation is provided by a shunt regulator. Galileo PMAD distributes a 570-W beginning of mission (BOM) power source to a user complement of some 137 load elements. Extensive use of pyrotechnics requires two pyro switching subassemblies. They initiate 148 squibs which operate the 47 pyro devices on the spacecraft. Detection and correction of faults in the Galileo PMAD is an autonomous feature dictated by requirements for long life and reliability in the absence of ground-based support. Volatile computer memories in the spacecraft command and data system and attitude control system require a continuous source of backup power during all anticipated power bus fault scenarios. Power for the Jupiter Probe is conditioned, isolated, and controlled by a Probe interface subassembly. Flight performance of the spacecraft and the PMAD has been successful to date, with no major anomalies.

  8. Diffuse scarring alopecia in a female pattern hair loss distribution.

    PubMed

    Fergie, Bonnie; Khaira, Gurpreet; Howard, Vicki; de Zwaan, Sally

    2017-02-17

    We describe three cases of hair loss in a female pattern hair loss (FPHL) distribution with histologic features of lichen planopilaris (LPP). All patients had a history of diffuse, gradual hair loss in a Christmas tree pattern that clinically presented as FPHL on gross and dermoscopic examination. Notably, there were no characteristic clinical signs of LPP and no histologic features of FPHL. These cases are most consistent with cicatricial pattern hair loss (CPHL). This relatively new entity is similar to fibrosing alopecia in a pattern distribution (FAPD) in that they are both scarring alopecias confined to a FPHL distribution, but CPHL lacks the clinical signs of perifollicular erythema and perifollicular keratosis seen in FAPD. These three cases may present an early, subtle form of CPHL and will be of interest to clinicians and histopathologists alike. © 2017 The Australasian College of Dermatologists.

  9. On loss distributions from installment-repaid loans.

    PubMed

    Crowder, Martin; Hand, David J

    2005-12-01

    The banks have been accumulating huge data bases for many years and are increasingly turning to statistics to provide insight into customer behaviour, among other things. Credit risk is an important issue and certain stochastic models have been developed in recent years to describe and predict loan default. Two of the major models currently used in the industry are considered here, and various ways of extending their application to the case where a loan is repaid in installments are explored. The aspect of interest is the probability distribution of the total loss due to repayment default at some time. Thus, the loss distribution is determined by the distribution of times to default, here regarded as a discrete-time survival distribution. In particular, the probabilities of large losses are to be assessed for insurance purposes.

  10. A mechanism producing power law etc. distributions

    NASA Astrophysics Data System (ADS)

    Li, Heling; Shen, Hongjun; Yang, Bin

    2017-07-01

    Power law distribution is playing an increasingly important role in the complex system study. Based on the insolvability of complex systems, the idea of incomplete statistics is utilized and expanded, three different exponential factors are introduced in equations about the normalization condition, statistical average and Shannon entropy, with probability distribution function deduced about exponential function, power function and the product form between power function and exponential function derived from Shannon entropy and maximal entropy principle. So it is shown that maximum entropy principle can totally replace equal probability hypothesis. Owing to the fact that power and probability distribution in the product form between power function and exponential function, which cannot be derived via equal probability hypothesis, can be derived by the aid of maximal entropy principle, it also can be concluded that maximal entropy principle is a basic principle which embodies concepts more extensively and reveals basic principles on motion laws of objects more fundamentally. At the same time, this principle also reveals the intrinsic link between Nature and different objects in human society and principles complied by all.

  11. Power Management and Distribution System Developed for Thermionic Power Converters

    NASA Technical Reports Server (NTRS)

    Baez, Anastacio N.

    1998-01-01

    A spacecraft solar, bimodal system combines propulsion and power generation into a single integrated system. An Integrated Solar Upper Stage (ISUS) provides orbital transfer capabilities, power generation for payloads, and onboard propulsion to the spacecraft. A key benefit of a bimodal system is a greater payload-to-spacecraft mass ratio resulting in lower launch vehicle requirements. Scaling down to smaller launch vehicles increases space access by reducing overall mission cost. NASA has joined efforts with the Air Force Phillips Laboratory to develop enabling technologies for such a system. The NASA/Air Force bimodal concept uses solar concentrators to focus energy into an integrated power plant. This power plant consists of a graphite core that stores thermal energy within a cavity. An array of thermionic converters encircles the graphite cavity and provides electrical energy conversion functions. During the power generation phase of the bimodal system, the thermionic converters are exposed to the heated cavity and convert the thermal energy to electricity. Near-term efforts of the ISUS bimodal program are focused on a ground demonstration of key technologies in order to proceed to a full space flight test. Thermionic power generation is one key technology of the bimodal concept. Thermionic power converters impose unique operating requirements upon a power management and distribution (PMAD) system design. Single thermionic converters supply large currents at very low voltages. Operating voltages can vary over a range of up to 3 to 1 as a function of operating temperature. Most spacecraft loads require regulated 28-volts direct-current (Vdc) power. A combination of series-connected converters and powerprocessing boosters is required to deliver power to the spacecraft's payloads at this level.

  12. Power loss in electrical steel under elliptically rotating flux conditions

    SciTech Connect

    Salz, W.; Hempel, K.A.

    1996-03-01

    The power loss of electrical steel sheet given in the data sheets of the steel manufacturers is related to linearly alternating flux conditions, measured with an Epstein frame or a single sheet tester, respectively. In the application of the material in electrical machines, the authors find large areas with rotational flux conditions, i.e., in the T-joint region of three-phase power transformers or above the stator teeth of three-phase motors and generators. The most general description of the magnetization process in this case is an elliptically rotating flux. The paper outlines the magnetic behavior of steel sheet under these flux conditions, and finally defines a simple method to predict the total power loss under elliptically rotating flux from data measured under linearly alternating and circularly rotating flux conditions only.

  13. Uncertainty evaluation in BEACON power distribution monitoring

    SciTech Connect

    Morita, T.; Goldstein, N.P. )

    1989-11-01

    BEACON is an advanced operational core support package that has a three-dimensional nodal code as its cornerstone. The three-dimensional calculation includes all necessary pressurized water reactor feedback effects. The generation of the measured power distribution from the core instrumentation is one of the primary functions of the core-monitoring software. The purpose of this paper is to discuss evaluation of the uncertainty in the measured assembly power from the BEACON system. The study covers not only the normal operating conditions, but off-normal situations to demonstrate BEACON's applicability for that condition.

  14. Water losses dynamic modelling in water distribution networks

    NASA Astrophysics Data System (ADS)

    Puleo, Valeria; Milici, Barbara

    2015-12-01

    In the last decades, one of the main concerns of the water system managers have been the minimisation of water losses, that frequently reach values of 30% or even 70% of the volume supplying the water distribution network. The economic and social costs associated with water losses in modern water supply systems are rapidly rising to unacceptably high levels. Furthermore, the problem of the water losses assumes more and more importance mainly when periods of water scarcity occur or when not sufficient water supply takes part in areas with fast growth. In the present analysis, a dynamic model was used for estimating real and apparent losses of a real case study. A specific nodal demand model reflecting the user's tank installation and a specific apparent losses module were implemented. The results from the dynamic model were compared with the modelling estimation based on a steady-state approach.

  15. Distributed Wireless Power Transfer With Energy Feedback

    NASA Astrophysics Data System (ADS)

    Lee, Seunghyun; Zhang, Rui

    2017-04-01

    Energy beamforming (EB) is a key technique for achieving efficient radio-frequency (RF) transmission enabled wireless energy transfer (WET). By optimally designing the waveforms from multiple energy transmitters (ETs) over the wireless channels, they can be constructively combined at the energy receiver (ER) to achieve an EB gain that scales with the number of ETs. However, the optimal design of EB waveforms requires accurate channel state information (CSI) at the ETs, which is challenging to obtain practically, especially in a distributed system with ETs at separate locations. In this paper, we study practical and efficient channel training methods to achieve optimal EB in a distributed WET system. We propose two protocols with and without centralized coordination, respectively, where distributed ETs either sequentially or in parallel adapt their transmit phases based on a low-complexity energy feedback from the ER. The energy feedback only depends on the received power level at the ER, where each feedback indicates one particular transmit phase that results in the maximum harvested power over a set of previously used phases. Simulation results show that the two proposed training protocols converge very fast in practical WET systems even with a large number of distributed ETs, while the protocol with sequential ET phase adaptation is also analytically shown to converge to the optimal EB design with perfect CSI by increasing the training time. Numerical results are also provided to evaluate the performance of the proposed distributed EB and training designs as compared to other benchmark schemes.

  16. Zero loss magnetic metamaterials using powered active unit cells.

    PubMed

    Yuan, Yu; Popa, Bogdan-Ioan; Cummer, Steven A

    2009-08-31

    We report the design and experimental measurement of a powered active magnetic metamaterial with tunable permeability. The unit cell is based on the combination of an embedded radiofrequency amplifier and a tunable phase shifter, which together control the response of the medium. The measurements show that a negative permeability metamaterial with zero loss or even gain can be achieved through an array of such metamaterial cells. This kind of active metamaterial can find use in applications that are performance limited due to material losses.

  17. Mixtures of multivariate power exponential distributions.

    PubMed

    Dang, Utkarsh J; Browne, Ryan P; McNicholas, Paul D

    2015-12-01

    An expanded family of mixtures of multivariate power exponential distributions is introduced. While fitting heavy-tails and skewness have received much attention in the model-based clustering literature recently, we investigate the use of a distribution that can deal with both varying tail-weight and peakedness of data. A family of parsimonious models is proposed using an eigen-decomposition of the scale matrix. A generalized expectation-maximization algorithm is presented that combines convex optimization via a minorization-maximization approach and optimization based on accelerated line search algorithms on the Stiefel manifold. Lastly, the utility of this family of models is illustrated using both toy and benchmark data.

  18. Relativity, nonextensivity, and extended power law distributions.

    PubMed

    Silva, R; Lima, J A S

    2005-11-01

    A proof of the relativistic theorem by including nonextensive effects is given. As it happens in the nonrelativistic limit, the molecular chaos hypothesis advanced by Boltzmann does not remain valid, and the second law of thermodynamics combined with a duality transformation implies that the parameter lies on the interval [0,2]. It is also proven that the collisional equilibrium states (null entropy source term) are described by the relativistic power law extension of the exponential Juttner distribution which reduces, in the nonrelativistic domain, to the Tsallis power law function. As a simple illustration of the basic approach, we derive the relativistic nonextensive equilibrium distribution for a dilute charged gas under the action of an electromagnetic field . Such results reduce to the standard ones in the extensive limit, thereby showing that the nonextensive entropic framework can be harmonized with the space-time ideas contained in the special relativity theory.

  19. Helicopter optimal descent and landing after power loss

    NASA Technical Reports Server (NTRS)

    Johnson, W.

    1977-01-01

    An optimal control solution is obtained for the descent and landing of a helicopter after the loss of power in level flight. The model considers the helicopter vertical velocity, horizontal velocity, and rotor speed; and it includes representations of ground effect, rotor inflow time lag, pilot reaction time, rotor stall, and the induced velocity curve in the vortex ring state. The control (rotor thrust magnitude and direction) required to minimize the vertical and horizontal velocity at contact with the ground is obtained using nonlinear optimal control theory. It is found that the optimal descent after power loss in hover is a purely vertical flight path. Good correlation, even quantitatively, is found between the calculations and (non-optimal) flight test results.

  20. Effects of size distribution on hysteresis losses of magnetic nanoparticles for hyperthermia.

    PubMed

    Hergt, Rudolf; Dutz, Silvio; Röder, Michael

    2008-09-24

    For understanding hysteresis losses of magnetic nanoparticles to be used for magnetic particle hyperthermia the effect of size distribution on the dependence of hysteresis losses on magnetic field amplitude is studied on the basis of a phenomenological model in the size range from superparamagnetism to magnetic multi-domains-roughly 10 up to 100 nm. Relying on experimental data for the size dependence of coercivity, an empirical expression for the dependence of hysteresis loss on field amplitude and particle size is derived for hypothetical monodisperse particle ensembles. Considering experimentally observable size distributions, the dependence of loss on distribution parameters-mean particle size and variance-is studied. There, field amplitude is taken into account as an important parameter, which for technical and biomedical reasons in hyperthermia equipment is restricted. Experimental results for different particle types with mean diameter of 30 nm may be well reproduced theoretically if a small loss contribution of Rayleigh type is taken into account. Results show that the Stoner-Wohlfarth model for single domain magnetization reversal via homogeneous rotation cannot explain experimental observations. In particular, in magnetosomes which are distinguished by nearly ideal crystallographic shapes and narrow size distribution large friction-like losses occur even for small field amplitude. Parameters of the high frequency field for hyperthermia (amplitude and frequency) as well as of the size distribution of applied particles are discussed with respect to attaining maximum specific heating power.

  1. Electrical power systems for distributed generation

    SciTech Connect

    Robertson, T.A.; Huval, S.J.

    1996-12-31

    {open_quotes}Distributed Generation{close_quotes} has become the {open_quotes}buzz{close_quotes} word of an electric utility industry facing deregulation. Many industrial facilities utilize equipment in distributed installations to serve the needs of a thermal host through the capture of exhaust energy in a heat recovery steam generator. The electrical power generated is then sold as a {open_quotes}side benefit{close_quotes} to the cost-effective supply of high quality thermal energy. Distributed generation is desirable for many different reasons, each with unique characteristics of the product. Many years of experience in the distributed generation market has helped Stewart & Stevenson to define a range of product features that are crucial to most any application. The following paper will highlight a few of these applications. The paper will also examine the range of products currently available and in development. Finally, we will survey the additional services offered by Stewart & Stevenson to meet the needs of a rapidly changing power generation industry.

  2. Reduction of water losses by rehabilitation of water distribution network.

    PubMed

    Güngör, Mahmud; Yarar, Ufuk; Firat, Mahmut

    2017-09-11

    Physical or real losses may be indicated as the most important component of the water losses occurring in a water distribution network (WDN). The objective of this study is to examine the effects of piping material management and network rehabilitation on the physical water losses and water losses management in a WDN. For this aim, the Denizli WDN consisting of very old pipes that have exhausted their economic life is selected as the study area. The fact that the current network is old results in the decrease of pressure strength, increase of failure intensity, and inefficient use of water resources thus leading to the application of the rehabilitation program. In Denizli, network renewal works have been carried out since the year 2009 under the rehabilitation program. It was determined that the failure rate at regions where network renewal constructions have been completed decreased down to zero level. Renewal of piping material enables the minimization of leakage losses as well as the failure rate. On the other hand, the system rehabilitation has the potential to amortize itself in a very short amount of time if the initial investment cost of network renewal is considered along with the operating costs of the old and new systems, as well as water loss costs. As a result, it can be stated that renewal of piping material in water distribution systems, enhancement of the physical properties of the system, provide significant contributions such as increase of water and energy efficiency and more effective use of resources.

  3. Lower hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.; Brunner, D.; LaBombard, B.; Parker, R. R.; Terry, J. L.; Whyte, D. G.; Baek, S. G.; Edlund, E.; Hubbard, A. E.; Hughes, J. W.; Kuang, A. Q.; Reinke, M. L.; Shiraiwa, S.; Wallace, G. M.; Walk, J. R.

    2016-05-01

    For the first time, the power deposition of lower hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal, and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt ( t < τ E ) response of the scrape-off-layer (SOL) plasma to Lower Hybrid Radiofrequency (LHRF) power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be a key for the LHRF edge power deposition physics. These observations support the existence of a loss mechanism near the edge for LHRF at high density ( n e > 1.0 × 10 20 (m-3)). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivate the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch.

  4. Tailoring the energy distribution and loss of 2D plasmons

    NASA Astrophysics Data System (ADS)

    Lin, Xiao; Rivera, Nicholas; López, Josué J.; Kaminer, Ido; Chen, Hongsheng; Soljačić, Marin

    2016-10-01

    The ability to tailor the energy distribution of plasmons at the nanoscale has many applications in nanophotonics, such as designing plasmon lasers, spasers, and quantum emitters. To this end, we analytically study the energy distribution and the proper field quantization of 2D plasmons with specific examples for graphene plasmons. We find that the portion of the plasmon energy contained inside graphene (energy confinement factor) can exceed 50%, despite graphene being infinitely thin. In fact, this very high energy confinement can make it challenging to tailor the energy distribution of graphene plasmons just by modifying the surrounding dielectric environment or the geometry, such as changing the separation distance between two coupled graphene layers. However, by adopting concepts of parity-time symmetry breaking, we show that tuning the loss in one of the two coupled graphene layers can simultaneously tailor the energy confinement factor and propagation characteristics, causing the phenomenon of loss-induced plasmonic transparency.

  5. Microwave Driven Actuators Power Allocation and Distribution

    NASA Technical Reports Server (NTRS)

    Forbes, Timothy; Song, Kyo D.

    2000-01-01

    Design, fabrication and test of a power allocation and distribution (PAD) network for microwave driven actuators is presented in this paper. Development of a circuit that would collect power from a rectenna array amplify and distribute the power to actuators was designed and fabricated for space application in an actuator array driven by a microwave. A P-SPICE model was constructed initially for data reduction purposes, and was followed by a working real-world model. A voltage up - converter (VUC) is used to amplify the voltage from the individual rectenna. The testing yielded a 26:1 voltage amplification ratio with input voltage at 9 volts and a measured output voltage 230VDC. Future work includes the miniaturization of the circuitry, the use of microwave remote control, and voltage amplification technology for each voltage source. The objective of this work is to develop a model system that will collect DC voltage from an array of rectenna and propagate the voltage to an array of actuators.

  6. Detection of Frauds and Other Non-technical Losses in Power Utilities using Smart Meters: A Review

    NASA Astrophysics Data System (ADS)

    Ahmad, Tanveer; Ul Hasan, Qadeer

    2016-06-01

    Analysis of losses in power distribution system and techniques to mitigate these are two active areas of research especially in energy scarce countries like Pakistan to increase the availability of power without installing new generation. Since total energy losses account for both technical losses (TL) as well as non-technical losses (NTLs). Utility companies in developing countries are incurring of major financial losses due to non-technical losses. NTLs lead to a series of additional losses, such as damage to the network (infrastructure and the reduction of network reliability) etc. The purpose of this paper is to perform an introductory investigation of non-technical losses in power distribution systems. Additionally, analysis of NTLs using consumer energy consumption data with the help of Linear Regression Analysis has been carried out. This data focuses on the Low Voltage (LV) distribution network, which includes: residential, commercial, agricultural and industrial consumers by using the monthly kWh interval data acquired over a period (one month) of time using smart meters. In this research different prevention techniques are also discussed to prevent illegal use of electricity in the distribution of electrical power system.

  7. Simulation Study of Gyrotron Traveling Wave Amplifier with Distributed-Loss in Facilities for Aquaculture

    NASA Astrophysics Data System (ADS)

    Hua, Xufeng; Chen, Chengxun; Xu, Dawei; Xing, Kezhi

    In this paper, we introduce a W-band gyro-traveling wave (gyro-TWT) tube to suppress spurious oscillations, which is used in facilities for Aquaculture. The spurious oscillations block achieving high gain and high power in high-power broadband millimeter amplifier. In order to suppress spurious oscillations, we study the interaction circuit including input coupler and output section, design the gyro-traveling wave tube with distributed-loss based on MIG. The results of simulation show that high power and broad-band capabilities.

  8. Influence of the UV-induced fiber loss on the distributed feedback fiber lasers

    NASA Astrophysics Data System (ADS)

    Fan, Wei; Chen, Bai; Qiao, Qiquan; Chen, Jialing; Lin, Zunqi

    2003-06-01

    It was found that the output power of the distributed feedback fiber lasers would be improved after annealing or left unused for several days after the laser had been fabricated, and the output of the fundamental mode would not increase but be clamped while the ±1 order modes would be predominant with the enhancement of the coupling coefficient during the fabrication. The paper discussed the influence of UV-induced fiber loss on the fiber phase-shifted DFB lasers. Due to the gain saturation and fiber internal loss, which included the temperament loss and permanent loss, there was an optimum coupling coefficient for the DFB fiber lasers that the higher internal fiber loss corresponded to the lower optimum values of coupling coefficient.

  9. Noise analysis in power distribution systems

    NASA Astrophysics Data System (ADS)

    Danisor, Alin

    2016-12-01

    This paper proposes an analysis, especially in time domain, of the electrical noise existent on the power distribution lines. This study is important for the use of powerlines as a channel of information transmissions. This information may refer to analog signals and as well to digital signals. The main problem addressed in this paper consists in the characterization of the background noise and to establish his statistical proprieties. It is very important to know if the noise induced in the transmission channel is a stationary one, or even an ergodic one. The main parameters like the mean value, the mean square value were determined in this paper. The approximation of the probability density function of each statistical parameter was studied. The pulses induced in the transmission channel by the transient phenomena of the power electrical systems were considered deterministic signals and their contributions were not included in this study.

  10. Power system operations: State estimation distributed processing

    NASA Astrophysics Data System (ADS)

    Ebrahimian, Mohammad Reza

    We present an application of a robust and fast parallel algorithm to power system state estimation with minimal amount of modifications to existing state estimators presently in place using the Auxiliary Problem Principle. We demonstrate its effectiveness on IEEE test systems, the Electric Reliability Counsel of Texas (ERCOT), and the Southwest Power Pool (SPP) systems. Since state estimation formulation may lead to an ill-conditioned system, we provide analytical explanations of the effects of mixtures of measurements on the condition of the state estimation information matrix. We demonstrate the closeness of the analytical equations to condition of several test case systems including IEEE RTS-96 and IEEE 118 bus systems. The research on the condition of the state estimation problem covers the centralized as well as distributed state estimation.

  11. Lowland tapir distribution and habitat loss in South America.

    PubMed

    Cordeiro, Jose Luis Passos; Fragoso, José M V; Crawshaw, Danielle; Oliveira, Luiz Flamarion B

    2016-01-01

    The development of species distribution models (SDMs) can help conservation efforts by generating potential distributions and identifying areas of high environmental suitability for protection. Our study presents a distribution and habitat map for lowland tapir in South America. We also describe the potential habitat suitability of various geographical regions and habitat loss, inside and outside of protected areas network. Two different SDM approaches, MAXENT and ENFA, produced relative different Habitat Suitability Maps for the lowland tapir. While MAXENT was efficient at identifying areas as suitable or unsuitable, it was less efficient (when compared to the results by ENFA) at identifying the gradient of habitat suitability. MAXENT is a more multifaceted technique that establishes more complex relationships between dependent and independent variables. Our results demonstrate that for at least one species, the lowland tapir, the use of a simple consensual approach (average of ENFA and MAXENT models outputs) better reflected its current distribution patterns. The Brazilian ecoregions have the highest habitat loss for the tapir. Cerrado and Atlantic Forest account for nearly half (48.19%) of the total area lost. The Amazon region contains the largest area under protection, and the most extensive remaining habitat for the tapir, but also showed high levels of habitat loss outside protected areas, which increases the importance of support for proper management.

  12. Lowland tapir distribution and habitat loss in South America

    PubMed Central

    Fragoso, José M.V.; Crawshaw, Danielle; Oliveira, Luiz Flamarion B.

    2016-01-01

    The development of species distribution models (SDMs) can help conservation efforts by generating potential distributions and identifying areas of high environmental suitability for protection. Our study presents a distribution and habitat map for lowland tapir in South America. We also describe the potential habitat suitability of various geographical regions and habitat loss, inside and outside of protected areas network. Two different SDM approaches, MAXENT and ENFA, produced relative different Habitat Suitability Maps for the lowland tapir. While MAXENT was efficient at identifying areas as suitable or unsuitable, it was less efficient (when compared to the results by ENFA) at identifying the gradient of habitat suitability. MAXENT is a more multifaceted technique that establishes more complex relationships between dependent and independent variables. Our results demonstrate that for at least one species, the lowland tapir, the use of a simple consensual approach (average of ENFA and MAXENT models outputs) better reflected its current distribution patterns. The Brazilian ecoregions have the highest habitat loss for the tapir. Cerrado and Atlantic Forest account for nearly half (48.19%) of the total area lost. The Amazon region contains the largest area under protection, and the most extensive remaining habitat for the tapir, but also showed high levels of habitat loss outside protected areas, which increases the importance of support for proper management. PMID:27672509

  13. Structure Learning in Power Distribution Networks

    SciTech Connect

    Deka, Deepjyoti; Chertkov, Michael; Backhaus, Scott N.

    2015-01-13

    Traditionally power distribution networks are either not observable or only partially observable. This complicates development and implementation of new smart grid technologies, such as these related to demand response, outage detection and management, and improved load-monitoring. Here, inspired by proliferation of the metering technology, we discuss statistical estimation problems in structurally loopy but operationally radial distribution grids consisting in learning operational layout of the network from measurements, e.g. voltage data, which are either already available or can be made available with a relatively minor investment. Our newly suggested algorithms apply to a wide range of realistic scenarios. The algorithms are also computationally efficient – polynomial in time – which is proven theoretically and illustrated computationally on a number of test cases. The technique developed can be applied to detect line failures in real time as well as to understand the scope of possible adversarial attacks on the grid.

  14. Interaction of lightning with power distribution lines

    NASA Astrophysics Data System (ADS)

    Mata, Carlos Tomas

    Triggered-lightning experiments were conducted in 1996, 1999, and 2000 to study the responses of overhead power distribution lines to lightning at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The lightning was artificially initiated (triggered) from natural thunderclouds using the rocket-and-wire technique, and its current was directed to a phase conductor at midspan or at a pole near the center of the line. Experimental results and associated EMTP modeling are presented in this dissertation for the following line configurations: (1)a two-conductor, 740-m overhead distribution line with 2 arrester stations in 1996; (2)a four- conductor, 245-m overhead distribution line with 2 arrester stations in 1999; and (3)a four-conductor, 829-m overhead distribution line with 6 arrester stations in 2000. The three-phase lines tested in 1999 and 2000 were standard designs of a major Florida power company. Lightning peak currents injected into the lines ranged from 7 to 57 kA. Voltages and currents were measured at various locations along the line. Video and photographic cameras were used to image lightning channels and detect line flashovers. The significant results of the research are (1)flashovers between conductors were observed, both accompanied and not accompanied by arrester failures, (2)an arrester failed on seven of eight direct lightning strikes to the line in 2000, (3)arcing between conductors may prevent failures of arresters connected to the struck phase, (4)the bulk of the lightning current flows from the struck phase to neutral through the arresters closest to the strike point, (5)the withstand energy of the arresters can be exceeded due to the contribution from multiple strokes and/or relatively low-level, long-lasting current components, (6)the distribution of charge transferred to ground among multiple neutral grounds, which is determined by low-frequency, low-current grounding resistances is different from the

  15. A Review of Distributed Control Techniques for Power Quality Improvement in Micro-grids

    NASA Astrophysics Data System (ADS)

    Zeeshan, Hafiz Muhammad Ali; Nisar, Fatima; Hassan, Ahmad

    2017-05-01

    Micro-grid is typically visualized as a small scale local power supply network dependent on distributed energy resources (DERs) that can operate simultaneously with grid as well as in standalone manner. The distributed generator of a micro-grid system is usually a converter-inverter type topology acting as a non-linear load, and injecting harmonics into the distribution feeder. Hence, the negative effects on power quality by the usage of distributed generation sources and components are clearly witnessed. In this paper, a review of distributed control approaches for power quality improvement is presented which encompasses harmonic compensation, loss mitigation and optimum power sharing in multi-source-load distributed power network. The decentralized subsystems for harmonic compensation and active-reactive power sharing accuracy have been analysed in detail. Results have been validated to be consistent with IEEE standards.

  16. Power Law Distributions in Two Community Currencies

    NASA Astrophysics Data System (ADS)

    Kichiji, N.; Nishibe, M.

    2007-07-01

    The purpose of this paper is to highlight certain newly discovered social phenomena that accord with Zipf's law, in addition to the famous natural and social phenomena including word frequencies, earthquake magnitude, city size, income1 etc. that are already known to follow it. These phenomena have recently been discovered within the transaction amount (payments or receipts) distributions within two different Community Currencies (CC) that had been initiated as social experiments. One is a local CC circulating in a specific geographical area, such as a town. The other is a virtual CC used among members who belong to a certain community of interest (COI) on the Internet. We conducted two empirical studies to estimate the economic vitalization effects they had on their respective local economies. The results we found were that the amount of transactions (payments and receipts) of the two CCs was distributed according to a power-law distribution with a unity rank exponent. In addition, we found differences between the two CCs with regard to the shapes of their distribution over a low-transaction range. The result may originate from the difference in methods of issuing CCs or in the magnitudes of the minimum-value unit; however, this result calls for further investigation.

  17. Distribution system power flow analysis; A rigid approach

    SciTech Connect

    Chen, T.H.; Chen, M.S.; Hwang, K.J. . Energy Systems Research Center); Kotas, P.; Chebli, E.A. )

    1991-07-01

    This paper introduces a rigid approach to three-phase distribution power flow analysis for large-scale distribution systems. This approach is oriented toward applications in distribution system operational analysis rather than planning analysis. This difference should be properly emphasized, otherwise, the misuse of the planning-type method to analyze the operational behavior of the system will distort the explanation of the calculated results and lead to incorrect conclusions. The solution method is the optimally ordered triangular factorization Y{sub Bus} Method (implicit Z{sub Bus} Gauss Method) which not only takes advantage of the sparsity of system equations but also has very good convergence characteristics on distribution problems. Detailed component models and suitable solution techniques are the essence of an accurate simulation. Detailed component models, therefore, are needed for all system components in the simulation. Utilizing the phase frame representation for all network elements, a program, entitled Generalized Distribution Analysis Systems - GDAS, with a number of features and capabilities not found in existing packages has been developed for large-scale distribution system simulations. The system being analyzed can be balanced or unbalanced and can be a radial, network, or mixed type distribution system. Furthermore, because the individual phase representation is employed for both system and component models, the system can comprise single, double, and three-phase systems simultaneously. Additionally, with detailed component models, the program can also perform system loss and contingency analyses.

  18. Ice Accretion Prediction on Wind Turbines and Consequent Power Losses

    NASA Astrophysics Data System (ADS)

    Yirtici, Ozcan; Tuncer, Ismail H.; Ozgen, Serkan

    2016-09-01

    Ice accretion on wind turbine blades modifies the sectional profiles and causes alteration in the aerodynamic characteristic of the blades. The objective of this study is to determine performance losses on wind turbines due to the formation of ice in cold climate regions and mountainous areas where wind energy resources are found. In this study, the Blade Element Momentum method is employed together with an ice accretion prediction tool in order to estimate the ice build-up on wind turbine blades and the energy production for iced and clean blades. The predicted ice shapes of the various airfoil profiles are validated with the experimental data and it is shown that the tool developed is promising to be used in the prediction of power production losses of wind turbines.

  19. Improved method for loss minimization in distribution networks

    SciTech Connect

    Borozan, V.; Rajicic, D.; Ackovski, R.

    1995-08-01

    A heuristic method for determining the distribution network configuration with minimum resistive line losses is described. This method is based on optimality condition developed by Merlin and Back. Using a fast and reliable load flow solution technique and introducing efficient algorithms for network elements inspection, that methodology becomes suitable for a real-time application. The proposed method is tested on a three test-systems, used in literature for the same purposes. Its efficiency advantages are especially emphasized in its application on distribution networks of realistic size.

  20. Abstract: Power losses in a conducting sheet with bar domains. III. Complete solution for cyclic losses

    NASA Astrophysics Data System (ADS)

    Lorenz, B. E.; Coren, R. L.

    1982-03-01

    The total, temporally averaged, expected power density loss due to the combined actions of the Barkhausen (B) and Pry-Bean (PB) mechanisms is p¯ = (ρ/V)(JB+JPB)2 dV (1) = p¯ B+p¯ PB+2(ρ/V)JBṡJPB dV where p¯B is given by Eq. (II.15),b) p¯PB is the expression derived by Pry and Bean, multiplied by (1-K)2, and V is the domain volume. The last term in Eq. (1) is a result of the simultaneus occurrence of both currents. In evaluating p¯B it was noted in paper II that the B currents from each switching site/section only flow for the time τ so that it was appropriate to consider energies instead of power. In terms of Eq. (II.15): p¯B = fE(w)¯, where f = frequency. This consideration must also enter into the cross term in Eq. (1). Space in this abstract limits the discussion of this term, but one may estimate its behavior by taking the currents to be rms values. Then p¯ = ˙p¯ B+p¯ PB+2(pB pPB)1/2. (2) Since pPB∝f2 and pB∝f, this cross term varies as f3/2; the energy density per cycle becomes W = p¯ /f = ˙(A1+A2√f¯+A3f)C, (3) where the A's are functions of the model parameters K and a, and C is a common function of the material properties. The middle term in Eq. (3) is new. Comparison with experiments and analysis of data available in the literature is difficult and unreliable because of the uncertain sample parameters and magnetic state relative to the assumptions entering Eq. (3). However, several works on 3.5% Si-Fe lead us to infer the values: a≊10 000/sec and K≊0.1. Similarly, direct comparison of Eq. (3) is inconclusive although some agreement is found in cases where the experimental magnetic parameters can be determined. The traditional view of magnetic reversal has large wall traps and smaller Barkhausen switches superimposed upon the continuous wall motion. These all may actually represent different regimes of a continuous distribution of behavioral properties. The present model separates and approximates the trapped regions and larger

  1. Robust distribution and use of electric power

    NASA Astrophysics Data System (ADS)

    Catalan Izquierdo, Saturnino

    2001-07-01

    One of the major problems related to the simultaneous operation of electrical converters in a wide open power system is the concordance between the characteristics of the feeder itself and the load. Nowadays we usually call Electric Power Quality or Electromagnetic Compatibility to this Concordance Degree. Currently, the most important non concordance are voltage sag (voltage dip) and short time interruptions, that is: decreasings in voltage RMS value lasting from some tenths of a second to several seconds. Current analysis usually study this problem from the feeder side, by means of morphological or stadistical approaches, or from the load side in order to evaluate immunity, emission or specific solutions. This line of research, undoubtly needed provided we need to know the current state of the power system and to increase the concordance degree, is not enough because of the huge variability between power lines and from one instant to another. Moreover, the legal boundaries that can support business decisions are not developed yet. The proposed new theory is widely contrasted by field and laboratory measurement. Detailed analysis include instant voltage, instant current, power system and load effects from many places inside the power system of Spain. This theory is a novel approach to the determination of Concordance Degree (CG) of a whole system (be it a distribution line or a single machine) and to the corrective steps needed to increase it. In addition, the proposed model allow a quantitative evaluation of corrective actions like the increase of energy system storage (in a mechanical to electrical convertible form) or/and the increase of the supplied reactive power. Profitability of corrective actions is mainly a function of the number of voltage dips (sags) and short time interruptions that happen in a given period of time. To reduce this number we have studied and developed new fault characterization and location algorithms designed specifically for medium

  2. Reflectance loss of prospective solar concentrator mirrors in erosive environments. The Crosbyton Solar Power Project

    SciTech Connect

    Bethea, R.M.; Barringer, M.T.; Chin, S.; Collier, E.G.; Cooper, A.M.; Reichert, J.D. Jr.; Williams, P.F.

    1986-01-01

    The problem addressed in this phase of the Crosbyton Solar Power Project was that of the effect of weathering of solar concentrator mirrors proposed for use in the fixed-mirror, distributed-focus (solar bowl) system with particular emphasis on erosion due to exposure during dust storms. The specific objectives of this research were to evaluate the mirrors with respect to initial reflectance, loss of reflectance due to dust storms and other outdoor exposure phenomena, and dimensional stability; and to develop a rapid technique for the simulation of dust storms so that a model for such reflectance loss as a function of exposure could be developed.

  3. Significance of losses in water distribution systems in India

    PubMed Central

    Raman, V.

    1983-01-01

    Effective management of water supply systems consists in supplying adequate quantities of clean water to the population. Detailed pilot studies of water distribution systems were carried out in 9 cities in India during 1971-81 to establish the feasibility of a programme of assessment, detection, and control of water losses from supply systems. A cost-benefit analysis was carried out. Water losses from mains and service pipes in the areas studied amounted to 20-35% of the total flow in the system. At a conservative estimate, the national loss of processed water through leaks in the water distribution systems amounts to 1012 litres per year, which is equivalent to 500 million rupees. It is possible to bring down the water losses in the pipe mains to 3-5% of the total flow, and the cost incurred on the control programme can be recovered in 6-18 months. Appropriate conservation measures will help in achieving the goals of the International Water Supply and Sanitation Decade to provide clean water for all. PMID:6418401

  4. Klystron Cluster Scheme for ILC High Power RF Distribution

    SciTech Connect

    Nantista, Christopher; Adolphsen, Chris; /SLAC

    2009-07-06

    We present a concept for powering the main linacs of the International Linear Collider (ILC) by delivering high power RF from the surface via overmoded, low-loss waveguides at widely spaced intervals. The baseline design employs a two-tunnel layout, with klystrons and modulators evenly distributed along a service tunnel running parallel to the accelerator tunnel. This new idea eliminates the need for the service tunnel. It also brings most of the warm heat load to the surface, dramatically reducing the tunnel water cooling and HVAC requirements. In the envisioned configuration, groups of 70 klystrons and modulators are clustered in surface buildings every 2.5 km. Their outputs are combined into two half-meter diameter circular TE{sub 01} mode evacuated waveguides. These are directed via special bends through a deep shaft and along the tunnel, one upstream and one downstream. Each feeds approximately 1.25 km of linac with power tapped off in 10 MW portions at 38 m intervals. The power is extracted through a novel coaxial tap-off (CTO), after which the local distribution is as it would be from a klystron. The tap-off design is also employed in reverse for the initial combining.

  5. Evaluation of Loss of Offsite Power Events at Nuclear Power Plants: 1980 - 1996

    SciTech Connect

    C. L. Atwood; D. A. Prawdzik; D. L. Kelly; F. M. Marshall; J. W. Stetkar

    1999-08-01

    It is recognized that the availability of AC power to commercial nuclear power plants is essential for safe operations and accident recovery. A loss of offsite power (LOSP) event, therefore, is considered an important contributor to total risk at nuclear power plants. In 1988, the U. S. Nuclear Regulatory Commission published NUREG-1032 to report on an evaluation of the risk from actual LOSP events that had occurred at nuclear power plants within the United States up through 1985. This paper summarizes a similar study, whose primary objective was to update the LOSP model parameters, frequency and recovery time, using power plant event data from 1980-1996, published as NUREG/CR-5496 in 1998. An additional objective of the study is to re-examine the engineering insights concerning LOSP events.

  6. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    NASA Astrophysics Data System (ADS)

    Leung, Ho Yan; Budgett, David M.; Taberner, Andrew; Hu, Patrick

    2014-09-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter.

  7. Global wetlands: Potential distribution, wetland loss, and status.

    PubMed

    Hu, Shengjie; Niu, Zhenguo; Chen, Yanfen; Li, Lifeng; Zhang, Haiying

    2017-05-15

    Even though researchers have paid a great deal of attention to wetland loss and status, the actual extent of wetland loss on a global scale, especially the loss caused directly by human activities, and the actual extent of currently surviving wetlands remains uncertain. This paper simulated the potential distribution of global wetlands by employing a new Precipitation Topographic Wetness Index (PTWI) and global remote sensing training samples. The results show earth would have approximately 29.83millionkm(2) of wetlands, if humans did not interfere with wetland ecosystems. By combining datasets related to global wetlands, we found that at least 33% of global wetlands had been lost as of 2009, including 4.58millionkm(2) of non-water wetlands and 2.64millionkm(2) of open water. The areal extent of wetland loss has been greatest in Asia, but Europe has experienced the most serious losses. Wetland-related datasets suffer from major inconsistencies, and estimates of the areal extent of the remaining global wetlands ranged from 1.53 to 14.86millionkm(2). Therefore, although it is challenging, thematic mapping of global wetlands is necessary and urgently needed.

  8. Effect of the electron energy distribution on total energy loss with argon in inductively coupled plasmas

    SciTech Connect

    Kim, June Young; Kim, Young-Cheol; Kim, Yu-Sin; Chung, Chin-Wook

    2015-01-15

    The total energy lost per electron-ion pair lost ε{sub T} is investigated with the electron energy distribution function (EEDF). The EEDFs are measured at various argon powers in RF inductively coupled plasma, and the EEDFs show a depleted distribution (a discontinuity occurring at the minimum argon excitation threshold energy level) with the bulk temperature and the tail temperature. The total energy loss per electron-ion pair lost ε{sub T} is calculated from a power balance model with the Maxwellian EEDFs and the depleted EEDFs and then compared with the measured ε{sub T} from the floating probe. It is concluded that the small population of the depleted high energy electrons dramatically increases the collisional energy loss, and the calculated ε{sub T} from the depleted EEDFs has a value that is similar to the measured ε{sub T}.

  9. Electric power processing, distribution, management and energy storage

    NASA Technical Reports Server (NTRS)

    Giudici, R. J.

    1980-01-01

    Power distribution subsystems are required for three elements of the SPS program: (1) orbiting satellite, (2) ground rectenna, and (3) Electric Orbiting Transfer Vehicle (EOTV). Power distribution subsystems receive electrical power from the energy conversion subsystem and provide the power busses rotary power transfer devices, switchgear, power processing, energy storage, and power management required to deliver control, high voltage plasma interactions, electric thruster interactions, and spacecraft charging of the SPS and the EOTV are also included as part of the power distribution subsystem design.

  10. A MILP-Based Distribution Optimal Power Flow Model for Microgrid Operation

    SciTech Connect

    Liu, Guodong; Starke, Michael R; Zhang, Xiaohu; Tomsovic, Kevin

    2016-01-01

    This paper proposes a distribution optimal power flow (D-OPF) model for the operation of microgrids. The proposed model minimizes not only the operating cost, including fuel cost, purchasing cost and demand charge, but also several performance indices, including voltage deviation, network power loss and power factor. It co-optimizes the real and reactive power form distributed generators (DGs) and batteries considering their capacity and power factor limits. The D-OPF is formulated as a mixed-integer linear programming (MILP). Numerical simulation results show the effectiveness of the proposed model.

  11. Satellite control of electric power distribution

    NASA Technical Reports Server (NTRS)

    Bergen, L.

    1981-01-01

    An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

  12. Stable harmonic multiplying gyrotron traveling-wave amplifier with distributed wall losses and attenuating severs

    SciTech Connect

    Yeh, Y. S.; Cheng, J. H.; Chen, L. K.; Hung, C. W.; Lo, C. Y.; Liao, C. W.

    2008-02-15

    Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWTs) provide magnetic field reduction and frequency multiplication. However, spurious oscillations may reduce the amplification of the gyro-TWT. Most distributed-loss structures are stabilized in gyro-TWTs that operate at low beam currents. Attenuating severs are added to the interaction circuit of a distributed-loss gyro-TWT to prevent high beam currents that result in mode competition. This study proposes a Ka-band harmonic multiplying gyro-TWT, using distributed wall losses and attenuating severs, to improve the stability of the amplification and the performance of the amplifier. Simulation results reveal that the absolute instabilities are effectively suppressed by wall losses of the lossy and severed sections, especially in the low-k{sub z} and high-order modes. Meanwhile, the severed section, dividing an interaction circuit into several short sections, reduces the effective interaction lengths of the absolute instabilities. The stable harmonic multiplying gyro-TWT is predicted to yield a peak output power of 230 kW at 33.65 GHz with an efficiency of 30%, a saturated gain of 40 dB, and a 3 dB bandwidth of 0.8 GHz for a 60 kV, 13 A electron beam with an axial velocity spread of {delta}v{sub z}/v{sub z}=8%. The power/gain scaling and phase relation between the drive and the output waves are elucidated.

  13. Device for the distribution of motive power

    SciTech Connect

    Teroka, M.

    1986-12-30

    A device is described for the distribution of motive power comprising: a hollow shaft receiving input power from the drive device; a pinion shaft provided on the output side of the hollow shaft; a pinion gear rotatably supported on the pinion shaft; a pair of side gears meshed with the pinion gear; a front wheel drive shaft integrally coupled to one of the side gears and passing through the center of the hollow shaft; a differential case having an outer shell, a front and a rear end and being integrally formed with the outer side gear and enclosing the pinion shaft, pinion gear and side gears. A rear wheel drive shaft is coupled to the differential case through a drive gear formed on the outer shell of the differential case and an input gear is integrally connected to an end of the rear wheel drive shaft so as to mesh with the drive gear, the rear drive wheel drive shaft being located above the front wheel drive shaft.

  14. Healthcare Assistants: distributional losses as a consequence of NHS modernisation?

    PubMed Central

    Clark, Ian; Thompson, Amanda

    2015-01-01

    This paper examines the labour process of Healthcare Assistants (HCAs) at a National Health Service (NHS) hospital trust (TUH) in the context of the NHS modernisation agenda. It determines whether application of the modernisation agenda is formalised at TUH and considers how HCAs are affected. The paper is based upon 60 interviews with HCAs, structured questionnaires completed by all interview respondents, observation of HCAs and interviews with non‐clinical managers. The findings show that elements of the modernisation agenda are informally implemented at TUH to the detriment of HCAs. HCAs experience distributional losses in the form of intensification as nurses deflect duties to HCAs and insulate themselves from adverse effects. HCAs resist, using selective absence when pressures mount. They ameliorate losses by re‐internalising their work as a job with caring elements not a genuine caring role. They rationalise their altered behaviour towards patients by blaming the regime's treatment of them as a subordinated group. PMID:27570359

  15. RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM

    SciTech Connect

    N. Ramirez

    2004-12-16

    A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

  16. Evaluating the effects of real power losses in optimal power flow based storage integration

    DOE PAGES

    Castillo, Anya; Gayme, Dennice

    2017-03-27

    This study proposes a DC optimal power flow (DCOPF) with losses formulation (the `-DCOPF+S problem) and uses it to investigate the role of real power losses in OPF based grid-scale storage integration. We derive the `- DCOPF+S problem by augmenting a standard DCOPF with storage (DCOPF+S) problem to include quadratic real power loss approximations. This procedure leads to a multi-period nonconvex quadratically constrained quadratic program, which we prove can be solved to optimality using either a semidefinite or second order cone relaxation. Our approach has some important benefits over existing models. It is more computationally tractable than ACOPF with storagemore » (ACOPF+S) formulations and the provably exact convex relaxations guarantee that an optimal solution can be attained for a feasible problem. Adding loss approximations to a DCOPF+S model leads to a more accurate representation of locational marginal prices, which have been shown to be critical to determining optimal storage dispatch and siting in prior ACOPF+S based studies. Case studies demonstrate the improved accuracy of the `-DCOPF+S model over a DCOPF+S model and the computational advantages over an ACOPF+S formulation.« less

  17. An improved AVC strategy applied in distributed wind power system

    NASA Astrophysics Data System (ADS)

    Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.

    2016-08-01

    Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.

  18. Patch Network for Power Allocation and Distribution in Smart Materials

    NASA Technical Reports Server (NTRS)

    Golembiewski, Walter T.

    2000-01-01

    The power allocation and distribution (PAD) circuitry is capable of allocating and distributing a single or multiple sources of power over multi-elements of a power user grid system. The purpose of this invention is to allocate and distribute power that is collected by individual patch rectennas to a region of specific power-user devices, such as actuators. The patch rectenna converts microwave power into DC power. Then this DC power is used to drive actuator devices. However, the power from patch rectennas is not sufficient to drive actuators unless all the collected power is effectively used to drive another group by allocation and distribution. The power allocation and distribution (PAD) circuitry solves the shortfall of power for devices in a large array. The PAD concept is based on the networked power control in which power collected over the whole array of rectennas is allocated to a sub domain where a group of devices is required to be activated for operation. Then the allocated power is distributed to individual element of power-devices in the sub domain according to a selected run-mode.

  19. Patch Network for Power Allocation and Distribution in Smart Materials

    NASA Technical Reports Server (NTRS)

    Golembiewski, Walter T.

    2000-01-01

    The power allocation and distribution (PAD) circuitry is capable of allocating and distributing a single or multiple sources of power over multi-elements of a power user grid system. The purpose of this invention is to allocate and distribute power that is collected by individual patch rectennas to a region of specific power-user devices, such as actuators. The patch rectenna converts microwave power into DC power. Then this DC power is used to drive actuator devices. However, the power from patch rectennas is not sufficient to drive actuators unless all the collected power is effectively used to drive another group by allocation and distribution. The power allocation and distribution (PAD) circuitry solves the shortfall of power for devices in a large array. The PAD concept is based on the networked power control in which power collected over the whole array of rectennas is allocated to a sub domain where a group of devices is required to be activated for operation. Then the allocated power is distributed to individual element of power-devices in the sub domain according to a selected run-mode.

  20. LH Power Losses In Front of the JET Launcher

    SciTech Connect

    Jacquet, P.; Arnoux, G.; Kirov, K.; Mailloux, J.; Mayoral, M.-L.; Ongena, J.

    2009-11-26

    In recent JET experiments, Lower Hybrid (LH) power losses in the Scrape-Off Layer (SOL) were characterized using infra-red (IR) thermography. Hot spots were observed on objects intercepting the field lines passing in front of the LH launcher, i.e. on poloidal limiters and on dumplates located at the top of the tokamak; their locations being in good agreement with magnetic field line tracing using the EFIT equilibrium code. The dumplate temperature was monitored while scanning the launcher position so that the radial distance between field lines intercepting the hot spots and the launcher was increased up to 3.5 cm. The dissipation layer in front of the launcher was estimated to be at least 3.5 cm wide, in agreement with recent measurements on Tore-Supra, but not with simple models that predict a dissipation layer in the mm range.

  1. LH Power Losses In Front of the JET Launcher

    NASA Astrophysics Data System (ADS)

    Jacquet, P.; Arnoux, G.; Colas, L.; Delpech, L.; Ekedahl, A.; Frigione, D.; Goniche, M.; Kirov, K.; Leguen, F.; Mailloux, J.; Mayoral, M.-L.; Ongena, J.; Petrzilka, V.; Portafaix, C.; Rimini, F.

    2009-11-01

    In recent JET experiments, Lower Hybrid (LH) power losses in the Scrape-Off Layer (SOL) were characterized using infra-red (IR) thermography. Hot spots were observed on objects intercepting the field lines passing in front of the LH launcher, i.e. on poloidal limiters and on dumplates located at the top of the tokamak; their locations being in good agreement with magnetic field line tracing using the EFIT equilibrium code. The dumplate temperature was monitored while scanning the launcher position so that the radial distance between field lines intercepting the hot spots and the launcher was increased up to 3.5 cm. The dissipation layer in front of the launcher was estimated to be at least 3.5 cm wide, in agreement with recent measurements on Tore-Supra, but not with simple models that predict a dissipation layer in the mm range.

  2. Business Pattern of Distributed Energy in Electric Power System Reformation

    NASA Astrophysics Data System (ADS)

    Liang, YUE; Zhuochu, LIU; Jun, LI; Siwei, LI

    2017-05-01

    Under the trend of the electric power system revolution, the operation mode of micro power grid that including distributed power will be more diversified. User’s demand response and different strategies on electricity all have great influence on the operation of distributed power grid. This paper will not only research sensitive factors of micro power grid operation, but also analyze and calculate the cost and benefit of micro power grid operation upon different types. Then it will build a tech-economic calculation model, which applies to different types of micro power grid under the reformation of electric power system.

  3. Rural electrification cost including transmission and distribution losses and investments

    SciTech Connect

    Sabharwal, S. )

    1990-09-01

    A procedure is proposed in this paper that incorporates the transmission and distribution costs in the electricity supply cost to the rural load centers. The energy supply cost to the rural loads includes the capacity and operating costs of generation, transmission and distribution and these costs are compared with energy supply from renewable sources of energy for their economic viability. A new method is suggested that determines the contribution of rural loads to the systems peak demand. Due to low load density and the high T and D losses in the rural areas the costs are higher for rural loads than the urban loads. The cost comparison are performed for four categories of rural loads-water pumping, LT industries, domestic/commercial and street lighting. The comparison also includes the hill districts vis a vis plains and electrified and unelectrified villages.

  4. Effect of spatial distribution of dissipated power on modeling of SMR BAW resonators at high power levels.

    PubMed

    Tag, Andreas; Bader, Bernhard; Huck, Christian; Karolewski, Dominik; Pitschi, Maximilian; Weigel, Robert; Hagelauer, Amelie

    2015-10-01

    The modeling of bulk acoustic wave resonators at elevated power levels has been improved by taking the spatial distribution of the dominating loss mechanisms into account. The spatial distribution of the dissipated power enables more accurate modeling of the temperature increase caused by the applied power. Thus, it is also possible to more accurately model the frequency shifts of the resonators' impedance curves resulting from the temperature increase caused by the applied power. Simulation and measurement results for the temperatures and impedances of the resonators with different layerstacks at high power loads are presented. The simulation and measurement results are in good agreement, confirming the presented modeling approach. Furthermore, the de-embedding procedure used to obtain vectorial scattering parameters of the resonators during high power loads, the according measurement setup, and the procedure for measuring absolute temperatures by infrared thermography are discussed.

  5. Influence of Mobile Users' Density Distribution on the CDMA Base Station Power

    NASA Astrophysics Data System (ADS)

    Lebl, Aleksandar; Mitić, Dragan; Popović, Miroslav; Markov, Žarko; Mileusnić, Mladen; Matić, Vladimir

    2016-12-01

    In this paper we analyze the influence of users' density distribution in one cell of CDMA mobile network (ie adjusted power control on the forward link) on base station emission power. This influence is analyzed for different circles radii around base station within which same emission power is generated for all mobile users, and for different values of propagation loss coefficient. It is proved that emission power in this cell must be increased comparing to the similar cell, which uses complete power control. The power increase is greater when greater number of users are situated near base station, and for greater values of propagation loss coefficient. The results are presented, illustrated by numerical examples and verified by simulation for three users' density distributions: uniform, decreasing and increasing density from the base station to the cell rim. The simulation process, which is based on random traffic process, is presented briefly.

  6. Developments in space power components for power management and distribution

    NASA Technical Reports Server (NTRS)

    Renz, D. D.

    1984-01-01

    Advanced power electronic components development for space applications is discussed. The components described include transformers, inductors, semiconductor devices such as transistors and diodes, remote power controllers, and transmission lines.

  7. Measurement of the temperature distribution inside the power cable using distributed temperature system

    NASA Astrophysics Data System (ADS)

    Jaros, Jakub; Liner, Andrej; Papes, Martin; Vasinek, Vladimir; Mach, Veleslav; Hruby, David; Kajnar, Tomas; Perecar, Frantisek

    2015-01-01

    Nowadays, the power cables are manufactured to fulfill the following condition - the highest allowable temperature of the cable during normal operation and the maximum allowable temperature at short circuit conditions cannot exceed the condition of the maximum allowable internal temperature. The distribution of the electric current through the conductor leads to the increase of the amplitude of electrons in the crystal lattice of the cables material. The consequence of this phenomenon is the increase of friction and the increase of collisions between particles inside the material, which causes the temperature increase of the carrying elements. The temperature increase is unwanted phenomena, because it is causing losses. In extreme cases, the long-term overload leads to the cable damaging or fire. This paper deals with the temperature distribution measurement inside the power cables using distributed temperature system. With cooperation with Kabex company, the tube containing optical fibers was installed into the center of power cables. These fibers, except telecommunications purposes, can be also used as sensors in measurements carrying out with distributed temperature system. These systems use the optical fiber as a sensor and allow the continual measurement of the temperature along the whole cable in real time with spatial resolution 1 m. DTS systems are successfully deployed in temperature measurement applications in industry areas yet. These areas include construction, drainage, hot water etc. Their advantages are low cost, resistance to electromagnetic radiation and the possibility of real time monitoring at the distance of 8 km. The location of the optical fiber in the center of the power cable allows the measurement of internal distribution of the temperature during overloading the cable. This measurement method can be also used for prediction of short-circuit and its exact location.

  8. Locational Marginal Pricing in the Campus Power System at the Power Distribution Level

    SciTech Connect

    Hao, Jun; Gu, Yi; Zhang, Yingchen; Zhang, Jun Jason; Gao, David Wenzhong

    2016-11-14

    In the development of smart grid at distribution level, the realization of real-time nodal pricing is one of the key challenges. The research work in this paper implements and studies the methodology of locational marginal pricing at distribution level based on a real-world distribution power system. The pricing mechanism utilizes optimal power flow to calculate the corresponding distributional nodal prices. Both Direct Current Optimal Power Flow and Alternate Current Optimal Power Flow are utilized to calculate and analyze the nodal prices. The University of Denver campus power grid is used as the power distribution system test bed to demonstrate the pricing methodology.

  9. Intensity distribution analysis of cathodoluminescence using the energy loss distribution of electrons.

    PubMed

    Fukuta, Masahiro; Inami, Wataru; Ono, Atsushi; Kawata, Yoshimasa

    2016-01-01

    We present an intensity distribution analysis of cathodoluminescence (CL) excited with a focused electron beam in a luminescent thin film. The energy loss distribution is applied to the developed analysis method in order to determine the arrangement of the dipole locations along the path of the electron traveling in the film. Propagating light emitted from each dipole is analyzed with the finite-difference time-domain (FDTD) method. CL distribution near the film surface is evaluated as a nanometric light source. It is found that a light source with 30 nm widths is generated in the film by the focused electron beam. We also discuss the accuracy of the developed analysis method by comparison with experimental results. The analysis results are brought into good agreement with the experimental results by introducing the energy loss distribution.

  10. Lower Hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.

    2015-11-01

    For the first time, the power deposition of Lower Hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt (t <τE) response of the scrape-off-layer (SOL) plasma to LHRF power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be key for the LHRF edge power deposition physics. These observations support the existence a loss mechanism near the edge for LHRF at high density (ne > 1 . 0 .1020 [m-3]). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivates the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch. This work was performed on the Alcator C-Mod tokamak, a DoE Office of Science user facility, and is supported by USDoE award DE-FC02-99ER54512.

  11. Analysis of Power Converter Losses in Vector Control System of a Self-Excited Induction Generator

    NASA Astrophysics Data System (ADS)

    Bašić, Mateo; Vukadinović, Dinko; Polić, Miljenko

    2014-03-01

    This paper provides analysis of losses in the hysteresis-driven three-phase power converter with IGBTs and free-wheeling diodes. The converter under consideration is part of the self-excited induction generator (SEIG) vector control system. For the analysis, the SEIG vector control system is used in which the induction generator iron losses are taken into account. The power converter losses are determined by using a suitable loss estimation algorithm reported in literature. The chosen algorithm allows the power converter losses to be determined both by type (switching/conduction losses) and by converter component (IGBT/diode losses). The overall power converter losses are determined over wide ranges of rotor speed, dc-link voltage and load resistance, and subsequently used for offline correction of the overall control system's losses (efficiency) obtained through control system simulations with an ideal power converter. The control system's efficiency values obtained after the correction are compared with the measured values.

  12. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2007-01-01

    Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.

  13. The invariances of power law size distributions.

    PubMed

    Frank, Steven A

    2016-01-01

    Size varies. Small things are typically more frequent than large things. The logarithm of frequency often declines linearly with the logarithm of size. That power law relation forms one of the common patterns of nature. Why does the complexity of nature reduce to such a simple pattern? Why do things as different as tree size and enzyme rate follow similarly simple patterns? Here I analyze such patterns by their invariant properties. For example, a common pattern should not change when adding a constant value to all observations. That shift is essentially the renumbering of the points on a ruler without changing the metric information provided by the ruler. A ruler is shift invariant only when its scale is properly calibrated to the pattern being measured. Stretch invariance corresponds to the conservation of the total amount of something, such as the total biomass and consequently the average size. Rotational invariance corresponds to pattern that does not depend on the order in which underlying processes occur, for example, a scale that additively combines the component processes leading to observed values. I use tree size as an example to illustrate how the key invariances shape pattern. A simple interpretation of common pattern follows. That simple interpretation connects the normal distribution to a wide variety of other common patterns through the transformations of scale set by the fundamental invariances.

  14. The invariances of power law size distributions

    PubMed Central

    Frank, Steven A.

    2016-01-01

    Size varies. Small things are typically more frequent than large things. The logarithm of frequency often declines linearly with the logarithm of size. That power law relation forms one of the common patterns of nature. Why does the complexity of nature reduce to such a simple pattern? Why do things as different as tree size and enzyme rate follow similarly simple patterns? Here I analyze such patterns by their invariant properties. For example, a common pattern should not change when adding a constant value to all observations. That shift is essentially the renumbering of the points on a ruler without changing the metric information provided by the ruler. A ruler is shift invariant only when its scale is properly calibrated to the pattern being measured. Stretch invariance corresponds to the conservation of the total amount of something, such as the total biomass and consequently the average size. Rotational invariance corresponds to pattern that does not depend on the order in which underlying processes occur, for example, a scale that additively combines the component processes leading to observed values. I use tree size as an example to illustrate how the key invariances shape pattern. A simple interpretation of common pattern follows. That simple interpretation connects the normal distribution to a wide variety of other common patterns through the transformations of scale set by the fundamental invariances. PMID:27928497

  15. Design note about a 75 KVA quiet power distribution system

    SciTech Connect

    Visser, A.T.

    1984-04-05

    This note describes a 75KVA quiet power distribution system for X 653 in neutrino Lab D. It is fed from the regular AC distribution which exists in the building and it has no standby power. Its purpose is to remove electrical disturbances which are present on the regular AC distribution.

  16. Energy summation method for energy loss computation in radial distribution networks

    SciTech Connect

    Taleski, R.; Rajicic, D.

    1996-05-01

    A method for energy loss calculation in radial distribution networks is presented. It is based on the statistical representation of the influence of different load curves in the network upon element power flows and on the oriented ordering of the network elements. Also, the paper proposes the use of different, but constant, voltages at each node, instead of nominal voltage at all nodes. The procedure is very simple, and it involves four steps: element ordering, calculation of second moments, power flow calculation with average loads at nodes, and energy calculation in network elements. The presented results illustrate that the algorithm has advantages over methods that use nominal voltage at each node for accuracy, and advantages over methods that calculate accurate energy losses for speed.

  17. Fuel Cycle Comparison for Distributed Power Technologies

    SciTech Connect

    Elgowainy, A.; Wang, M. Q.

    2008-11-15

    This report examines backup power and prime power systems and addresses the potential energy and environmental effects of substituting fuel cells for existing combustion technologies based on microturbines and internal combustion engines.

  18. Three-phase Unbalanced Interval Power Flow Calculation of Low-voltage Distribution Network with Distributed PV Power Generation

    NASA Astrophysics Data System (ADS)

    Yuan, Yan; Shunjiang, Lin; Yuan, Lu

    2017-05-01

    Low-voltage distribution network is a three-phase unbalanced system due to the integration of single-phase loads and single-phase distributed PV arrays. In this paper, three-phase unbalanced interval power flow calculation model of three-phase four-wire low voltage distribution network with distributed PV power generation is established. In the model, intensity of illumination and battery temperature which influence the power output of distributed PV power generation is described as intervals. Then, through the affine interval algorithm, the interval power flow problem is transformed into a deterministic power flow problem and two linear optimization problems. By solving the above problems, the interval power flow solution can be obtained. Finally, the proposed algorithm is applied to an actual 22-bus low-voltage distribution network, and the solution of the affine interval algorithm is compared to the solution of the Monte Carlo sampling method, which verifies the correctness and effectiveness of the proposed algorithm.

  19. Efficient two-level cryogenic power distribution system

    NASA Astrophysics Data System (ADS)

    Mueller, O. M.; Mueller, E. K.

    2002-05-01

    The availability of new technologies such as high-temperature superconducting (HTS) cables, high-voltage, high-speed semiconductor switches, and cryogenic power conversion suggests that one considers how these technologies can be combined and applied effectively to provide a more efficient energy distribution system. The present-day 60 Hz concept is, after all, a century old. Advantages can be obtained by combining DC and high-frequency AC technologies. DC transmission solves the problem of AC losses in HTS cables and high-frequency switching techniques reduce size, weight and cost. This paper proposes and discusses a distribution system based on two DC voltage levels (˜4 kVDC/650 VDC) interconnected with DC/DC converters using high-voltage insulated-gate bipolar transistors (HV-IGBT's), integrated gate-commutated thyristors (IGCT's), or MOS-controlled turn-off thyristors (MTO's) operated at cryogenic temperatures. Cryo-MOSFET DC/AC inverters provide the 60 Hz, 240/120 VAC user voltages. HTS cables supply power as well as the cooling fluid liquid nitrogen (LN2). The load shedding properties of such a system based on the use of LN2 are evaluated. The proposed concept is suitable for city blocks with many high-rise buildings. It provides an increase in efficiency and therefore contributes to the reduction of global warming.

  20. Power-Law Distributions Based on Exponential Distributions: Latent Scaling, Spurious Zipf's Law, and Fractal Rabbits

    NASA Astrophysics Data System (ADS)

    Chen, Yanguang

    2015-03-01

    The difference between the inverse power function and the negative exponential function is significant. The former suggests a complex distribution, while the latter indicates a simple distribution. However, the association of the power-law distribution with the exponential distribution has been seldom researched. This paper is devoted to exploring the relationships between exponential laws and power laws from the angle of view of urban geography. Using mathematical derivation and numerical experiments, I reveal that a power-law distribution can be created through a semi-moving average process of an exponential distribution. For the distributions defined in a one-dimension space (e.g. Zipf's law), the power exponent is 1; while for those defined in a two-dimension space (e.g. Clark's law), the power exponent is 2. The findings of this study are as follows. First, the exponential distributions suggest a hidden scaling, but the scaling exponents suggest a Euclidean dimension. Second, special power-law distributions can be derived from exponential distributions, but they differ from the typical power-law distributions. Third, it is the real power-law distributions that can be related with fractal dimension. This study discloses an inherent link between simplicity and complexity. In practice, maybe the result presented in this paper can be employed to distinguish the real power laws from spurious power laws (e.g. the fake Zipf distribution).

  1. Power Distribution Architecture for High Energy Physic Hostile Environment

    NASA Astrophysics Data System (ADS)

    Alderighi, M.; Citterio, M.; Latorre, S.; Riva, M.; Cova, P.; Delmonte, N.; Lanza, A.; Bernardoni, M.; Menozzi, R.; Costabeber, A.; Paccagnella, A.; Sichirollo, F.; Spiazzi, G.; Stellini, M.; Tenti, P.; Baccaro, S.; Iannuzzo, F.; Sanseverino, A.; Busatto, G.; de Luca, V.

    2012-08-01

    In the high luminosity phase of the Large Hadron Collider (LHC) the selection of the most suitable architecture able to supply the instrumentation of the experiments represents a critical task today. The power conversion units will have to supply low voltages and high currents to the loads with reduced transmission losses and, moreover, their design will have to face the critical demand of efficiency, robustness and limited size together with the need to operate in hostile environment. The paper discusses the most promising solutions in the power supply distribution networks which could be implemented in the upgraded detectors at the High Luminosity LHC collider. The proposed topologies have been selected by considering their tolerance to high background magnetic field and nuclear radiations as well as their limited electromagnetic noise emission. The analysis focuses on the description of the power supplies for noble liquid calorimeters, such as the Atlas LAr calorimeters, though several outcomes of this research can be applied to other detectors of the future LHC experiments.

  2. Distributed energy store powered railguns for hypervelocity launch

    NASA Astrophysics Data System (ADS)

    Maas, Brian L.; Bauer, David P.; Marshall, Richard A.

    1993-01-01

    Highly distributed power supplies are proposed as a basis for current difficulties with hypervelocity railgun power-supply compactness. This distributed power supply configuration reduces rail-to-rail voltage behind the main armature, thereby reducing the tendency for secondary armature current formation; secondary current elimination is essential for achieving the efficiencies associated with muzzle velocity above 6 km/sec. Attention is given to analytical and experimental results for two distributed energy storage schemes.

  3. Evolution of power law distributions in science and society.

    PubMed

    Jeon, Young-Pyo; McCoy, Benjamin J

    2005-09-01

    Power law distributions have been observed in numerous physical and social systems; for example, the size distributions of particles, aerosols, corporations, and cities are often power laws. Each system is an ensemble of clusters, comprising units that combine with or dissociate from the cluster. Constructing models and investigating their properties are needed to understand how such clusters evolve. To describe the growth of clusters, we hypothesize that a distribution obeys a governing population dynamics equation based on a reversible association-dissociation process. The rate coefficients are considered to depend on the cluster size as power expressions, thus providing an explanation for the asymptotic evolution of power law distributions.

  4. Evolution of power law distributions in science and society

    NASA Astrophysics Data System (ADS)

    Jeon, Young-Pyo; McCoy, Benjamin J.

    2005-09-01

    Power law distributions have been observed in numerous physical and social systems; for example, the size distributions of particles, aerosols, corporations, and cities are often power laws. Each system is an ensemble of clusters, comprising units that combine with or dissociate from the cluster. Constructing models and investigating their properties are needed to understand how such clusters evolve. To describe the growth of clusters, we hypothesize that a distribution obeys a governing population dynamics equation based on a reversible association-dissociation process. The rate coefficients are considered to depend on the cluster size as power expressions, thus providing an explanation for the asymptotic evolution of power law distributions.

  5. Personalized weight loss strategies-the role of macronutrient distribution.

    PubMed

    Martinez, J Alfredo; Navas-Carretero, Santiago; Saris, Wim H M; Astrup, Arne

    2014-12-01

    A large number of different dietary approaches have been studied in an attempt to achieve healthy, sustainable weight loss among individuals with overweight and obesity. Restriction of energy intake is the primary method of producing a negative energy balance leading to weight loss. However, owing to the different metabolic roles of proteins, carbohydrates and lipids in energy homeostasis, diets of similar overall energy content but with different macronutrient distribution can differentially affect metabolism, appetite and thermogenesis. Evidence increasingly suggests that the fuel values of calories provided by distinct macronutrients should be considered separately, as metabolism of specific molecular components generates differences in energy yield. The causes of variation in individual responses to various diets are currently under debate, and some evidence suggests that differences are associated with specific genotypes. This Review discusses all available systematic reviews and meta-analyses, and summarizes the results of relevant randomized controlled intervention trials assessing the influence of macronutrient composition on weight management. The initial findings of research into personalized nutrition, based on the interactions of macronutrient intake and genetic background and its potential influence on dietary intervention strategies, are also discussed.

  6. Specific loss power in superparamagnetic hyperthermia: nanofluid versus composite

    NASA Astrophysics Data System (ADS)

    Osaci, M.; Cacciola, M.

    2017-01-01

    Currently, the magnetic hyperthermia induced by nanoparticles is of great interest in biomedical applications. In the literature, we can find a lot of models for magnetic hyperthermia, but many of them do not give importance to a significant detail, such as the geometry of nanoparticle positions in the system. Usually, a nanofluid is treated by considering random positions of the nanoparticles, geometry that is actually characteristic to the composite nanoparticles. To assess the error which is frequently made, in this paper we propose a comparative analysis between the specific loss power (SLP) in case of a nanofluid and the SLP in case of a composite with magnetic nanoparticles. We are going to use a superparamagnetic hyperthermia model based on the improved model for calculating the Néel relaxation time in a magnetic field oblique to the nanoparticle magnetic anisotropy axes, and on the improved theoretical model LRT (linear response theory) for SLP. To generate the nanoparticle geometry in the system, we are going to apply a Monte Carlo method to a nanofluid, by minimising the interaction potentials in liquid medium and, for a composite environment, a method for generating random positions of the nanoparticles in a given volume.

  7. Prediction of reserves using multivariate power-normal mixture distribution

    NASA Astrophysics Data System (ADS)

    Ling, Ang Siew; Hin, Pooi Ah

    2016-10-01

    Recently, in the area on stochastic loss reserving, there are a number of papers which analyze the individual claims data using the Position Dependent Marked Poisson Process. The present paper instead uses a different type of individual data. For the i-th (1≤i≤n) customer, these individual data include the sum insured si together with the amount paid yi j and the amount ai j reported but not yet paid in the j-th (1 ≤ j ≤ 6) development year. A technique based on multivariate power-normal mixture distribution is already available for predicting the future value (yi j + 1, ai j + 1) using the present year value (yi j, ai j) and the sum insured si. Presently the above technique is improved by the transformation of distribution which is defined on the whole real line to one which is non-negative and having approximately the same first four moments as the original distribution. It is found that, for the dataset considered in this paper, the improved method gives a better estimate for the reserve when compared with the chain ladder reserve estimate. Furthermore, the method is expected to provide a fairly reliable value for the Provision of Risk Margin for Adverse Deviation (PRAD).

  8. Power Distribution of Hybrid Electric Vehicles

    NASA Astrophysics Data System (ADS)

    Kato, Kenta; Morimoto, Masayuki

    In this paper, the fuel consumption of the hybrid electric vehicles is analyzed by the rated power of the engine and the motor. The analysis was based on the published data only. Hybrid ratio and normalized fuel consumption are defined. As the result, the key for the high mileage of hybrid electric vehicle is to use the high power motor and the low power engine.

  9. Space Power Management and Distribution Status and Trends

    NASA Technical Reports Server (NTRS)

    Reppucci, G. M.; Biess, J. J.; Inouye, L.

    1984-01-01

    An overview of space power management and distribution (PMAD) is provided which encompasses historical and current technology trends. The PMAD components discussed include power source control, energy storage control, and load power processing electronic equipment. The status of distribution equipment comprised of rotary joints and power switchgear is evaluated based on power level trends in the public, military, and commercial sectors. Component level technology thrusts, as driven by perceived system level trends, are compared to technology status of piece-parts such as power semiconductors, capacitors, and magnetics to determine critical barriers.

  10. Efficiency and power loss in d. c. chopper circuits. [Theoretical calculation

    SciTech Connect

    Beck, M.O.

    1981-01-01

    The object of this paper was to investigate the efficiency and source of power losses of various classes of dc chopper circuits. The study involved a theoretical calculation of the power losses, supported by a considerable amount of practical work on full power-rated traction motor test bed. 3 refs.

  11. Fast wave heating and edge power losses in NSTX and NSTX-U

    NASA Astrophysics Data System (ADS)

    Bertelli, Nicola

    2013-10-01

    Experimental studies of high harmonic fast wave (HHFW) heating on the National Spherical Torus Experiment (NSTX) have demonstrated that substantial HHFW power loss can occur along the open field lines in the scrape-off layer (SOL), but the mechanism behind the loss is not yet understood. Extended ray tracing and full wave codes are being applied to specific NSTX discharges in order to predict the causes of this power loss. Previous full wave simulations predict that cavity-like modes may form outside of the LCFS. We find that inserting a collisional loss in the SOL of AORSA to represent a damping process indicates an effective collisional term of ν / ω ~ [ 0 . 05 - 0 . 1 ] which is considerably larger than the ν / ω ~ 0 . 005 obtained with Spitzer resistivity, suggesting the damping scale of the loss mechanism. The magnitude of the edge collisional losses are being used to evaluate possible potential damping mechanisms in the SOL. Initial numerical analyses show that the presence of the SOL has a significant impact on the launched antenna spectrum. The upgrade of NSTX, NSTX-U, will operate with toroidal magnetic fields (BT) up to 1 T, nearly twice the values used on NSTX. The doubling of BT while retaining the 30 MHz RF frequency moves the heating regime for NSTX-U to the mid harmonic fast wave (MHFW) regime, which will be analyzed and contrasted with the HHFW regime on NSTX. These studies indicate that direct ion damping might be more significant in NSTX-U under TRANSP predicted full performance conditions. Modifications of fast ion distributions due to the interaction of fast waves with NBI will be presented in both MHFW and HHFW regimes. Work supported by the SciDAC Center for Wave-Plasma Interactions under DE-FC02-01ER54648 and the US DOE under DE-AC02-CH0911466.

  12. PQScal (Power Quality Score Calculation for Distribution Systems with DER Integration)

    SciTech Connect

    2016-11-21

    Power Quality is of great importance to evaluate the “health” of a distribution system, especially when the distributed energy resource (DER) penetration becomes more significant. The individual components that make up power quality, such as voltage magnitude and unbalance, can be measured in simulations or in the field, however, a comprehensive method to incorporate all of these values into a single score doesn't exist. As a result, we propose a methodology to quantify the power quality health using the single number value, named as Power Quality Score (PQS). The PQS is dependent on six metrics that are developed based on both components that directly impact power quality and those are often reference in the context of power quality. These six metrics are named as System Average Voltage Magnitude Violation Index (SAVMVI), System Average Voltage Fluctuation Index (SAVFI), System Average Voltage Unbalance Index (SAVUI), System Control Device Operation Index (SCDOI), System Reactive Power Demand Index (SRPDI) and System Energy Loss Index (SELI). This software tool, PQScal, is developed based on this novel PQS methodology. Besides of traditional distribution systems, PQScal can also measure the power quality for distribution systems with various DER penetrations. PQScal has been tested on two utility distribution feeders with distinct model characteristics and its effectiveness has been proved. In sum, PQScal can help utilities or other parties to measure the power quality of distribution systems with DER integration easily and effectively.

  13. Price Based Local Power Distribution Management System (Local Power Distribution Manager) v1.0

    SciTech Connect

    BROWN, RICHARD E.; CZARNECKI, STEPHEN; SPEARS, MICHAEL; NORDMAN, BRUCE; BROUGHTON, ALEX; VON HIPPEL, MICHAEL; LIAO, ANNA

    2016-11-28

    A trans-active energy micro-grid controller is implemented in the VOLTTRON distributed control platform. The system uses the price of electricity as the mechanism for conducting transactions that are used to manage energy use and to balance supply and demand. In order to allow testing and analysis of the control system, the implementation is designed to run completely as a software simulation, while allowing the inclusion of selected hardware that physically manages power. Equipment to be integrated with the micro-grid controller must have an IP (Internet Protocol)-based network connection and a software "driver" must exist to translate data communications between the device and the controller.

  14. Refinements and practical implementation of a power based loss of grid detection algorithm for embedded generators

    NASA Astrophysics Data System (ADS)

    Barrett, James

    The incorporation of small, privately owned generation operating in parallel with, and supplying power to, the distribution network is becoming more widespread. This method of operation does however have problems associated with it. In particular, a loss of the connection to the main utility supply which leaves a portion of the utility load connected to the embedded generator will result in a power island. This situation presents possible dangers to utility personnel and the public, complications for smooth system operation and probable plant damage should the two systems be reconnected out-of-synchronism. Loss of Grid (or Islanding), as this situation is known, is the subject of this thesis. The work begins by detailing the requirements for operation of generation embedded in the utility supply with particular attention drawn to the requirements for a loss of grid protection scheme. The mathematical basis for a new loss of grid protection algorithm is developed and the inclusion of the algorithm in an integrated generator protection scheme described. A detailed description is given on the implementation of the new algorithm in a microprocessor based relay hardware to allow practical tests on small embedded generation facilities, including an in-house multiple generator test facility. The results obtained from the practical tests are compared with those obtained from simulation studies carried out in previous work and the differences are discussed. The performance of the algorithm is enhanced from the theoretical algorithm developed using the simulation results with simple filtering together with pattern recognition techniques. This provides stability during severe load fluctuations under parallel operation and system fault conditions and improved performance under normal operating conditions and for loss of grid detection. In addition to operating for a loss of grid connection, the algorithm will respond to load fluctuations which occur within a power island

  15. Minimizing Losses in a Space Laser Power Beaming System

    DTIC Science & Technology

    2010-03-01

    management model used by the satellite be it Peak Power Tracking or Direct Energy Transfer is evaluated in Sect. 3.4.3 because it directly effects the...component of the model it is important that they be as high as possible. The two power regulation schemes considered here are Peak Power Tracking (PPT...satellite. As discussed in Sect. 3.4.2 a direct energy transfer (DET) power model is 5% more efficient than the Peak Power Tracking (PPT) model

  16. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  17. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  18. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  19. Inverter power module with distributed support for direct substrate cooling

    DOEpatents

    Miller, David Harold [San Pedro, CA; Korich, Mark D [Chino Hills, CA; Ward, Terence G [Redondo Beach, CA; Mann, Brooks S [Redondo Beach, CA

    2012-08-21

    Systems and/or methods are provided for an inverter power module with distributed support for direct substrate cooling. An inverter module comprises a power electronic substrate. A first support frame is adapted to house the power electronic substrate and has a first region adapted to allow direct cooling of the power electronic substrate. A gasket is interposed between the power electronic substrate and the first support frame. The gasket is configured to provide a seal between the first region and the power electronic substrate. A second support frame is adapted to house the power electronic substrate and joined to the first support frame to form the seal.

  20. A Testbed for Deploying Distributed State Estimation in Power Grid

    SciTech Connect

    Jin, Shuangshuang; Chen, Yousu; Rice, Mark J.; Liu, Yan; Gorton, Ian

    2012-07-22

    Abstract—With the increasing demand, scale and data information of power systems, fast distributed applications are becoming more important in power system operation and control. This paper proposes a testbed for evaluating power system distributed applications, considering data exchange among distributed areas. A high-performance computing (HPC) version of distributed state estimation is implemented and used as a distributed application example. The IEEE 118-bus system is used to deploy the parallel distributed state estimation, and the MeDICi middleware is used for data communication. The performance of the testbed demonstrates its capability to evaluate parallel distributed state estimation by leveraging the HPC paradigm. This testbed can also be applied to evaluate other distributed applications.

  1. Power loss in open cavity diodes and a modified Child-Langmuir law

    SciTech Connect

    Biswas, Debabrata; Kumar, Raghwendra; Puri, R.R.

    2005-09-15

    Diodes used in most high power devices are inherently open. It is shown that under such circumstances, there is a loss of electromagnetic radiation leading to a lower critical current as compared to closed diodes. The power loss can be incorporated in the standard Child-Langmuir framework by introducing an effective potential. The modified Child-Langmuir law can be used to predict the maximum power loss for a given plate separation and potential difference as well as the maximum transmitted current for this power loss. The effectiveness of the theory is tested numerically.

  2. Joint-specific power loss after eccentric exercise.

    PubMed

    Elmer, Steven J; Martin, James C

    2010-09-01

    Previous investigators have reported changes in maximal power after eccentric exercise. The influence of eccentric joint-specific power absorption on subsequent concentric joint-specific power production during multijoint actions has not been reported. Our purposes were to determine the extent to which ankle, knee, and hip joint actions absorbed power during eccentric cycling (ECCcyc) and to evaluate changes in power produced by those joint actions during subsequent maximal concentric cycling (CONcyc). We hypothesized that joint actions that absorbed the most power during ECCcyc would exhibit the greatest reductions in power during subsequent maximal CONcyc. Nineteen cyclists performed baseline trials of maximal single-leg CONcyc immediately before and 24 h after acute single-leg ECCcyc (5 min, 40% maximum single-leg CONcyc power). Pedal forces and limb kinematics were determined with a force-sensing pedal and instrumented spatial linkage system, respectively. Joint-specific powers were calculated using inverse dynamics and averaged over complete crank revolutions and over extension and flexion phases. The largest power-absorbing actions during ECCcyc were eccentric knee extensor activity (-185 +/- 12 W) followed by eccentric hip extensor activity (-92 +/- 12 W). Power absorbed through ankle joint actions was small (-10 +/- 2 W). At 24 h, pedal power produced during maximal CONcyc was reduced by 11% +/- 3% relative to baseline. Compared with baseline, knee extension power was reduced by 19% +/- 0 7%, whereas hip extension power did not differ. Power absorbed through eccentric knee extension actions significantly reduced knee extension power produced during subsequent maximal CONcyc. Even with reduced knee extensor function, participants were able to deliver 89% of their baseline power to the environment. These results have implications for individuals who must continue to perform multijoint activities after eccentric exercise.

  3. Electron-beam-deposited distributed polarization rotator for high-power laser applications.

    PubMed

    Oliver, J B; Kessler, T J; Smith, C; Taylor, B; Gruschow, V; Hettrick, J; Charles, B

    2014-10-06

    Electron-beam deposition of silica and alumina is used to fabricate distributed polarization rotators suitable for smoothing the intensity of large-aperture, high-peak-power lasers. Low-modulation, low-loss transmittance with a high 351-nm laser-damage threshold is achieved.

  4. Brief communication: coaxial lines for multiphase power distribution.

    PubMed

    Barnes, F S; Harwick, P; Banerjee, A

    1996-01-01

    A coaxial cable can be used to reduce the magnetic and electric fields that extend into environments in the vicinity of transmission lines and distribution lines and in-house or building wiring for power distribution systems. The use of the coaxial geometry may prove useful in cases where there are environmental concerns with respect to health effects and in cases where there is a need to run high-speed data communications in close proximity to power distribution systems.

  5. Comparing Different Fault Identification Algorithms in Distributed Power System

    NASA Astrophysics Data System (ADS)

    Alkaabi, Salim

    A power system is a huge complex system that delivers the electrical power from the generation units to the consumers. As the demand for electrical power increases, distributed power generation was introduced to the power system. Faults may occur in the power system at any time in different locations. These faults cause a huge damage to the system as they might lead to full failure of the power system. Using distributed generation in the power system made it even harder to identify the location of the faults in the system. The main objective of this work is to test the different fault location identification algorithms while tested on a power system with the different amount of power injected using distributed generators. As faults may lead the system to full failure, this is an important area for research. In this thesis different fault location identification algorithms have been tested and compared while the different amount of power is injected from distributed generators. The algorithms were tested on IEEE 34 node test feeder using MATLAB and the results were compared to find when these algorithms might fail and the reliability of these methods.

  6. A study of power conditioning and power distribution and components

    NASA Technical Reports Server (NTRS)

    Horton, H. M.; Honnell, M. A.

    1973-01-01

    A comprehensive simulation and analysis performed on the operation of the regulator part of the Charger/Battery/Regulator Module (CBRM) are detailed. The CBRM is utilized as an integral component of the Skylab/Apollo Telescope Mount (ATM) electrical power system and contains a switching mode electronic regulator. Implementing circuit analysis techniques, pertinent voltages and currents are calculated; these, in turn, are incorporated into the regulator system study. Investigation of the turn-on and turn-off times associated with the switching circuitry is performed and an examination is made on these calculations. A simulation model computer program is utilized to generate graphs that relate various CBRM parameters to one another.

  7. Power balance and loss mechanism analysis in RF transmit coil arrays.

    PubMed

    Kuehne, Andre; Goluch, Sigrun; Waxmann, Patrick; Seifert, Frank; Ittermann, Bernd; Moser, Ewald; Laistler, Elmar

    2015-10-01

    To establish a framework for transmit array power balance calculations based on power correlation matrices to accurately quantify the loss contributions from different mechanisms such as coupling, lumped components, and radiation. Starting from Poynting's theorem, power correlation matrices are derived for all terms in the power balance, which is formulated as a matrix equation. Finite-difference time-domain simulations of two 7 T eight-channel head array coils at 297.2 MHz are used to verify the theoretical considerations and demonstrate their application. Care is taken to accurately incorporate all loss mechanisms. The power balance for static B1 phase shims as well as two-dimensional spatially selective transmit SENSE pulses is shown. The simulated power balance shows an excellent agreement with theory, with a maximum power imbalance of less than 0.11%. Power loss contributions from the different loss mechanisms vary significantly between the investigated setups, and depending on the excitation mode imposed on the coil. The presented approach enables a straightforward loss evaluation for an arbitrary excitation of transmit coil arrays. Worst-case power imbalance and losses are calculated in a straightforward manner. This allows for deeper insight into transmit array loss mechanisms, incorporation of radiated power components in specific absorption rate calculations and verification of electromagnetic simulations. © 2014 Wiley Periodicals, Inc.

  8. Thresholded Power law Size Distributions of Instabilities in Astrophysics

    NASA Astrophysics Data System (ADS)

    Aschwanden, Markus J.

    2015-11-01

    Power-law-like size distributions are ubiquitous in astrophysical instabilities. There are at least four natural effects that cause deviations from ideal power law size distributions, which we model here in a generalized way: (1) a physical threshold of an instability; (2) incomplete sampling of the smallest events below a threshold x0; (3) contamination by an event-unrelated background xb; and (4) truncation effects at the largest events due to a finite system size. These effects can be modeled in the simplest terms with a “thresholded power law” distribution function (also called generalized Pareto [type II] or Lomax distribution), N(x){dx}\\propto {(x+{x}0)}-a{dx}, where x0 > 0 is positive for a threshold effect, while x0 < 0 is negative for background contamination. We analytically derive the functional shape of this thresholded power law distribution function from an exponential growth evolution model, which produces avalanches only when a disturbance exceeds a critical threshold x0. We apply the thresholded power law distribution function to terrestrial, solar (HXRBS, BATSE, RHESSI), and stellar flare (Kepler) data sets. We find that the thresholded power law model provides an adequate fit to most of the observed data. Major advantages of this model are the automated choice of the power law fitting range, diagnostics of background contamination, physical instability thresholds, instrumental detection thresholds, and finite system size limits. When testing self-organized criticality models that predict ideal power laws, we suggest including these natural truncation effects.

  9. Power-law ansatz in complex systems: Excessive loss of information.

    PubMed

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  10. Power-law ansatz in complex systems: Excessive loss of information

    NASA Astrophysics Data System (ADS)

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  11. Novel binary PSO algorithm based optimization of transmission expansion planning considering power losses

    NASA Astrophysics Data System (ADS)

    Astuty; Haryono, T.

    2016-04-01

    Transmission expansion planning (TEP) is one of the issue that have to be faced caused by addition of large scale power generation into the existing power system. Optimization need to be conducted to get optimal solution technically and economically. Several mathematic methods have been applied to provide optimal allocation of new transmission line such us genetic algorithm, particle swarm optimization and tabu search. This paper proposed novel binary particle swarm optimization (NBPSO) to determine which transmission line should be added to the existing power system. There are two scenerios in this simulation. First, considering transmission power losses and the second is regardless transmission power losses. NBPSO method successfully obtain optimal solution in short computation time. Compare to the first scenario, the number of new line in second scenario which regardless power losses is less but produces high power losses that cause the cost becoming extremely expensive.

  12. Electric power processing, distribution and control for advanced aerospace vehicles.

    NASA Technical Reports Server (NTRS)

    Krausz, A.; Felch, J. L.

    1972-01-01

    The results of a current study program to develop a rational basis for selection of power processing, distribution, and control configurations for future aerospace vehicles including the Space Station, Space Shuttle, and high-performance aircraft are presented. Within the constraints imposed by the characteristics of power generation subsystems and the load utilization equipment requirements, the power processing, distribution and control subsystem can be optimized by selection of the proper distribution voltage, frequency, and overload/fault protection method. It is shown that, for large space vehicles which rely on static energy conversion to provide electric power, high-voltage dc distribution (above 100 V dc) is preferable to conventional 28 V dc and 115 V ac distribution per MIL-STD-704A. High-voltage dc also has advantages over conventional constant frequency ac systems in many aircraft applications due to the elimination of speed control, wave shaping, and synchronization equipment.

  13. System optimization of a long-range Brillouin-loss-based distributed fiber sensor.

    PubMed

    Dong, Yongkang; Chen, Liang; Bao, Xiaoyi

    2010-09-20

    We report a high-performance 25 km Brillouin-loss-based distributed fiber sensor through optimizing system parameters. First, the Brillouin spectrum distortion and measurement error induced by the excess amplification on probe pulse are investigated, and the results indicate that a low continuous-wave pump power is essential to decrease the measurement error. Then an optimal pulse pair is determined through the differential Brillouin gain evolution along the entire sensing fiber in a differential pulse-width pair Brillouin optical time domain analysis. Using dispersion-shifted fiber to allow a high-power probe pulse, we realize a 25 km sensing range with a spatial resolution of 30 cm and a strain accuracy of ±20 με, which we believe is the best performance in such a length, to the best of our knowledge.

  14. Statistical Analyses Support Power Law Distributions Found in Neuronal Avalanches

    PubMed Central

    Klaus, Andreas; Yu, Shan; Plenz, Dietmar

    2011-01-01

    The size distribution of neuronal avalanches in cortical networks has been reported to follow a power law distribution with exponent close to −1.5, which is a reflection of long-range spatial correlations in spontaneous neuronal activity. However, identifying power law scaling in empirical data can be difficult and sometimes controversial. In the present study, we tested the power law hypothesis for neuronal avalanches by using more stringent statistical analyses. In particular, we performed the following steps: (i) analysis of finite-size scaling to identify scale-free dynamics in neuronal avalanches, (ii) model parameter estimation to determine the specific exponent of the power law, and (iii) comparison of the power law to alternative model distributions. Consistent with critical state dynamics, avalanche size distributions exhibited robust scaling behavior in which the maximum avalanche size was limited only by the spatial extent of sampling (“finite size” effect). This scale-free dynamics suggests the power law as a model for the distribution of avalanche sizes. Using both the Kolmogorov-Smirnov statistic and a maximum likelihood approach, we found the slope to be close to −1.5, which is in line with previous reports. Finally, the power law model for neuronal avalanches was compared to the exponential and to various heavy-tail distributions based on the Kolmogorov-Smirnov distance and by using a log-likelihood ratio test. Both the power law distribution without and with exponential cut-off provided significantly better fits to the cluster size distributions in neuronal avalanches than the exponential, the lognormal and the gamma distribution. In summary, our findings strongly support the power law scaling in neuronal avalanches, providing further evidence for critical state dynamics in superficial layers of cortex. PMID:21720544

  15. Statistical analyses support power law distributions found in neuronal avalanches.

    PubMed

    Klaus, Andreas; Yu, Shan; Plenz, Dietmar

    2011-01-01

    The size distribution of neuronal avalanches in cortical networks has been reported to follow a power law distribution with exponent close to -1.5, which is a reflection of long-range spatial correlations in spontaneous neuronal activity. However, identifying power law scaling in empirical data can be difficult and sometimes controversial. In the present study, we tested the power law hypothesis for neuronal avalanches by using more stringent statistical analyses. In particular, we performed the following steps: (i) analysis of finite-size scaling to identify scale-free dynamics in neuronal avalanches, (ii) model parameter estimation to determine the specific exponent of the power law, and (iii) comparison of the power law to alternative model distributions. Consistent with critical state dynamics, avalanche size distributions exhibited robust scaling behavior in which the maximum avalanche size was limited only by the spatial extent of sampling ("finite size" effect). This scale-free dynamics suggests the power law as a model for the distribution of avalanche sizes. Using both the Kolmogorov-Smirnov statistic and a maximum likelihood approach, we found the slope to be close to -1.5, which is in line with previous reports. Finally, the power law model for neuronal avalanches was compared to the exponential and to various heavy-tail distributions based on the Kolmogorov-Smirnov distance and by using a log-likelihood ratio test. Both the power law distribution without and with exponential cut-off provided significantly better fits to the cluster size distributions in neuronal avalanches than the exponential, the lognormal and the gamma distribution. In summary, our findings strongly support the power law scaling in neuronal avalanches, providing further evidence for critical state dynamics in superficial layers of cortex.

  16. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  17. Loss of Load Probability Calculation for West Java Power System with Nuclear Power Plant Scenario

    NASA Astrophysics Data System (ADS)

    Azizah, I. D.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.; Shafii, M. A.

    2017-03-01

    Loss of Load Probability (LOLP) index showing the quality and performance of an electrical system. LOLP value is affected by load growth, the load duration curve, forced outage rate of the plant, number and capacity of generating units. This reliability index calculation begins with load forecasting to 2018 using multiple regression method. Scenario 1 with compositions of conventional plants produce the largest LOLP in 2017 amounted to 71.609 days / year. While the best reliability index generated in scenario 2 with the NPP amounted to 6.941 days / year in 2015. Improved reliability of systems using nuclear power more efficiently when compared to conventional plants because it also has advantages such as emission-free, inexpensive fuel costs, as well as high level of plant availability.

  18. Optimal Power Schedule for Distributed MIMO Links

    DTIC Science & Technology

    2006-11-01

    INTRODUCTION A multiple - input multiple - output ( MIMO ) wireless link is well known to provide a much higher capacity than a single- input single- output ...However, for a wireless network of multiple distributed MIMO links, such as a network in the future combat sys- tems, there are new issues of research...The existing MIMO theory is not sufficient for such a wireless network where multiple MIMO links cause mutual interferences to each other. This

  19. Low Power Computing in Distributed Systems

    DTIC Science & Technology

    2006-04-01

    IEEE Communications Magazine, Volume 40, Issue 8, pp. 102-114, Aug. 2002. [3] E. R . Post and M. Orth, “Smart Fabric, or Wearable Computing,” Proc...www.cse.psu.edu/~mdl/software.htm [20] http://carlsberg.mit.edu/JouleTrack/ [21] M. Srivastava, A. Chandrakasan. R . Brodersen, “Predictive system shutdown...Dynamic Load Balancing in Distributed Systems,” IEEE International Conference on Systems, Man and Cybernetics, pp. 3795-3799, 1995. [27] A. Talukder

  20. 26 CFR 1.731-1 - Extent of recognition of gain or loss on distribution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... recognition of gain or loss on distribution. (a) Recognition of gain or loss to partner—(1) Recognition of gain. (i) Where money is distributed by a partnership to a partner, no gain shall be recognized to the partner except to the extent that the amount of money distributed exceeds the adjusted basis of...

  1. 26 CFR 1.731-1 - Extent of recognition of gain or loss on distribution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... of recognition of gain or loss on distribution. (a) Recognition of gain or loss to partner—(1) Recognition of gain. (i) Where money is distributed by a partnership to a partner, no gain shall be recognized to the partner except to the extent that the amount of money distributed exceeds the adjusted...

  2. Description of a 20 Kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  3. Calculated CIM Power Distributions for Coil Design

    SciTech Connect

    Hardy, B.J.

    1999-02-17

    Excessive bed expansion and material expulsion have occurred during experiments with the 3-inch diameter Cylindrical Induction Melter (CIM). Both events were attributed in part to the high power density in the bottom of the melter and the correspondingly high temperatures there. It is believed that the high temperatures resulted in the generation of gasses at the bottom of the bed which could not escape. The gasses released during heating and the response of the bed to gas evolution depend upon the composition of the bed.

  4. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width, and ratio on total mesh power loss for a wide range of speeds, torques, and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling, and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine pitched gears had higher peak efficiencies but low part load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full load loss except at low speeds.

  5. Multi-objective optimal power flow for active distribution network considering the stochastic characteristic of photovoltaic

    NASA Astrophysics Data System (ADS)

    Zhou, Bao-Rong; Liu, Si-Liang; Zhang, Yong-Jun; Yi, Ying-Qi; Lin, Xiao-Ming

    2017-05-01

    To mitigate the impact on the distribution networks caused by the stochastic characteristic and high penetration of photovoltaic, a multi-objective optimal power flow model is proposed in this paper. The regulation capability of capacitor, inverter of photovoltaic and energy storage system embedded in active distribution network are considered to minimize the expected value of active power the T loss and probability of voltage violation in this model. Firstly, a probabilistic power flow based on cumulant method is introduced to calculate the value of the objectives. Secondly, NSGA-II algorithm is adopted for optimization to obtain the Pareto optimal solutions. Finally, the best compromise solution can be achieved through fuzzy membership degree method. By the multi-objective optimization calculation of IEEE34-node distribution network, the results show that the model can effectively improve the voltage security and economy of the distribution network on different levels of photovoltaic penetration.

  6. Space Station Freedom power management and distribution system design

    NASA Technical Reports Server (NTRS)

    Teren, Fred

    1989-01-01

    The design is described of the Space Station Freedom Power Management and Distribution (PMAD) System. In addition, the significant trade studies which were conducted are described, which led to the current PMAD system configuration.

  7. 99. POWER DISTRIBUTION UNITS FOR BATTERIES AND RECTIFIERS, NORTHEAST SIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    99. POWER DISTRIBUTION UNITS FOR BATTERIES AND RECTIFIERS, NORTHEAST SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. Shuttle Electrical Power Analysis Program (SEPAP) distribution circuit analysis report

    NASA Technical Reports Server (NTRS)

    Torina, E. M.

    1975-01-01

    An analysis and evaluation was made of the operating parameters of the shuttle electrical power distribution circuit under load conditions encountered during a normal Sortie 2 Mission with emphasis on main periods of liftoff and landing.

  9. Power distribution in two-dimensional optical network channels

    NASA Astrophysics Data System (ADS)

    Wang, Dong-Xue; Karim, Mohammad A.

    1996-04-01

    The power distribution in two-dimensional optical network channels is analyzed. The maximum number of allowable channels as determined by the characteristics of optical detector is identified, in particular, for neural-network and wavelet-transform applications.

  10. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2006-01-01

    Secondary seal leakage in jet engine applications results in power losses to the engine cycle. Likewise, seal power loss in jet engines not only result in efficiency loss but also increase the heat input into the engine resulting in reduced component lives. Experimental work on labyrinth and annular seals was performed at NASA Glenn Research Center to quantify seal leakage and power loss at various temperatures, seal pressure differentials, and surface speeds. Data from annular and labyrinth seals are compared with previous brush and finger seal test results. Data are also compared to literature. Annular and labyrinth seal leakage rates are 2 to 3 times greater than brush and finger seal rates. Seal leakage decreases with increasing speed but increases with increasing test temperature due to thermal expansion mismatch. Also seal power loss increases with surface speed, seal pressure differential, mass flow rate, and radial clearance. Annular and labyrinth seal power losses were higher than those of brush or finger seal data. The brush seal power loss was 15 to 30 percent lower than annular and labyrinth seal power loss.

  11. Power laws in citation distributions: evidence from Scopus.

    PubMed

    Brzezinski, Michal

    Modeling distributions of citations to scientific papers is crucial for understanding how science develops. However, there is a considerable empirical controversy on which statistical model fits the citation distributions best. This paper is concerned with rigorous empirical detection of power-law behaviour in the distribution of citations received by the most highly cited scientific papers. We have used a large, novel data set on citations to scientific papers published between 1998 and 2002 drawn from Scopus. The power-law model is compared with a number of alternative models using a likelihood ratio test. We have found that the power-law hypothesis is rejected for around half of the Scopus fields of science. For these fields of science, the Yule, power-law with exponential cut-off and log-normal distributions seem to fit the data better than the pure power-law model. On the other hand, when the power-law hypothesis is not rejected, it is usually empirically indistinguishable from most of the alternative models. The pure power-law model seems to be the best model only for the most highly cited papers in "Physics and Astronomy". Overall, our results seem to support theories implying that the most highly cited scientific papers follow the Yule, power-law with exponential cut-off or log-normal distribution. Our findings suggest also that power laws in citation distributions, when present, account only for a very small fraction of the published papers (less than 1 % for most of science fields) and that the power-law scaling parameter (exponent) is substantially higher (from around 3.2 to around 4.7) than found in the older literature.

  12. A new approach to the minimum weight/loss design of switching power converters

    NASA Technical Reports Server (NTRS)

    Lee, F. C.; Rahman, S.; Wu, C. J.; Kolacki, J.

    1981-01-01

    A new technique using the mathematical nonlinear programming ALAG is proposed to facilitate design optimizations of switching power converters. This computer-aided approach provides a minimum weight (or loss) design down to the details of component level and concurrently satisfies all related power-circuit performance requirements. It also provides such design insights as tradeoffs between power loss and system weight as the switching frequency is increased.

  13. A comparative study of electric power distribution systems for spacecraft

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.

    1990-01-01

    The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.

  14. Megawatt Space Power Conditioning, Distribution, and Control Study

    DTIC Science & Technology

    1988-03-01

    nmber) This study defined appropriate methodologies Tor conditioning, distribution, and controlling prime electrical power for megawatt level directed...procedures for conditioning, distributing, and controlling prime electrical power to help us better understand and identify critical mission enabling...INSULATION 2 MW KLYSTRODE Figure 2-2. Generator-VHV RF system (A) M2-011-88 8 on the negative dc bus . The generator frequency is not critical, but

  15. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  16. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P [Pasco, WA; Donnelly, Matthew K [Kennewick, WA; Dagle, Jeffery E [Richland, WA

    2011-12-06

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  17. Model of heat losses from underground heat distribution system

    NASA Astrophysics Data System (ADS)

    Čarnogurská, Mária; Příhoda, Miroslav; Dobáková, Romana; Brestovič, Tomáš

    2017-09-01

    The paper describes the linear density of the heat flow using dimensional analysis in the case of underground, pre-insulated piping. The methodology makes it possible to determine the heat loss based on a simple criterial relationship. Heat losses in the piping system were also calculated using numerical simulation. The difference between the experimentally detected losses and the values obtained from the model is -3.6% to 6.4%. The results of the numerical simulation at an ambient temperature of 25°C differ from the experiment by -1.7%. At an ambient temperature of -10°C the difference is -4.0%.

  18. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    NASA Technical Reports Server (NTRS)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  19. 62. View of amplifiermodulator control system with power distribution panel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. View of amplifier-modulator control system with power distribution panel on left, control power supply in middle, and amplifier modulator on right, second floor in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  20. Combined effect of CVR and penetration of DG in the voltage profile and losses of lowvoltage secondary distribution networks

    NASA Astrophysics Data System (ADS)

    Bokhari, Abdullah

    Demarcations between traditional distribution power systems and distributed generation (DG) architectures are increasingly evolving as higher DG penetration is introduced in the system. The concerns in existing electric power systems (EPSs) to accommodate less restrictive interconnection policies while maintaining reliability and performance of power delivery have been the major challenge for DG growth. In this dissertation, the work is aimed to study power quality, energy saving and losses in a low voltage distributed network under various DG penetration cases. Simulation platform suite that includes electric power system, distributed generation and ZIP load models is implemented to determine the impact of DGs on power system steady state performance and the voltage profile of the customers/loads in the network under the voltage reduction events. The investigation designed to test the DG impact on power system starting with one type of DG, then moves on multiple DG types distributed in a random case and realistic/balanced case. The functionality of the proposed DG interconnection is designed to meet the basic requirements imposed by the various interconnection standards, most notably IEEE 1547, public service commission, and local utility regulation. It is found that implementation of DGs on the low voltage secondary network would improve customer's voltage profile, system losses and significantly provide energy savings and economics for utilities. In a network populated with DGs, utility would have a uniform voltage profile at the customers end as the voltage profile becomes more concentrated around targeted voltage level. The study further reinforced the concept that the behavior of DG in distributed network would improve voltage regulation as certain percentage reduction on utility side would ensure uniform percentage reduction seen by all customers and reduce number of voltage violations.

  1. Wake losses from averaged and time-resolved power measurements at full scale wind turbines

    NASA Astrophysics Data System (ADS)

    Castellani, Francesco; Astolfi, Davide; Mana, Matteo; Becchetti, Matteo; Segalini, Antonio

    2017-05-01

    This work deals with the experimental analysis of wake losses fluctuations at full-scale wind turbines. The test case is a wind farm sited on a moderately complex terrain: 4 turbines are installed, having 2 MW of rated power each. The sources of information are the time-resolved data, as collected from the OPC server, and the 10-minutes averaged SCADA data. The objective is to compare the statistical distributions of wake losses for far and middle wakes, as can be observed through the “fast” lens of time-resolved data, for certain selected test-case time series, and through the “slow” lens of SCADA data, on a much longer time basis that allow to set the standards of the mean wake losses along the wind farm. Further, time-resolved data are used for an insight into the spectral properties of wake fluctuations, highlighting the role of the wind turbine as low-pass filter. Summarizing, the wind rose, the layout of the site and the structure of the data sets at disposal allow to study middle and far wake behavior, with a “slow” and “fast” perspective.

  2. A generalization of the power law distribution with nonlinear exponent

    NASA Astrophysics Data System (ADS)

    Prieto, Faustino; Sarabia, José María

    2017-01-01

    The power law distribution is usually used to fit data in the upper tail of the distribution. However, commonly it is not valid to model data in all the range. In this paper, we present a new family of distributions, the so-called Generalized Power Law (GPL), which can be useful for modeling data in all the range and possess power law tails. To do that, we model the exponent of the power law using a non-linear function which depends on data and two parameters. Then, we provide some basic properties and some specific models of that new family of distributions. After that, we study a relevant model of the family, with special emphasis on the quantile and hazard functions, and the corresponding estimation and testing methods. Finally, as an empirical evidence, we study how the debt is distributed across municipalities in Spain. We check that power law model is only valid in the upper tail; we show analytically and graphically the competence of the new model with municipal debt data in the whole range; and we compare the new distribution with other well-known distributions including the Lognormal, the Generalized Pareto, the Fisk, the Burr type XII and the Dagum models.

  3. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    SciTech Connect

    Touati, Said; Chennai, Salim; Souli, Aissa

    2015-07-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  4. The effect of solar array voltage patterns on plasma power losses

    NASA Technical Reports Server (NTRS)

    Mandell, M. J.; Katz, I.; Steen, P. G.; Schnuelle, G. W.

    1980-01-01

    The use of high-voltage solar arrays in space is discussed in connection with the draining of array power by currents flowing between exposed surfaces through the surrounding plasma. The possibility of reducing the power loss by arranging solar cell strings in repeated small-area modules to eliminate any large areas at high potentials is investigated. It is found that the difference in power loss between modular and linear patterned high-voltage arrays is fairly small. Although the use of modular patterns can reduce the effective mean potential by about 10%, for the type of configuration being considered there is also a 10% increase in sheath area, leading to only a few percent change in total power loss. It is concluded that plasma power loss should not be a primary consideration in designing the physical arrangement of high-voltage arrays.

  5. Analytical Limit Distributions from Random Power-Law Interactions

    NASA Astrophysics Data System (ADS)

    Zaid, Irwin; Mizuno, Daisuke

    2016-07-01

    Nature is full of power-law interactions, e.g., gravity, electrostatics, and hydrodynamics. When sources of such fields are randomly distributed in space, the superposed interaction, which is what we observe, is naively expected to follow a Gauss or Lévy distribution. Here, we present an analytic expression for the actual distributions that converge to novel limits that are in between these already-known limit distributions, depending on physical parameters, such as the concentration of field sources and the size of the probe used to measure the interactions. By comparing with numerical simulations, the origin of non-Gauss and non-Lévy distributions are theoretically articulated.

  6. Analysis of Apex Seal Friction Power Loss in Rotary Engines

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Owen, A. Karl

    2010-01-01

    An analysis of the frictional losses from the apex seals in a rotary engine was developed. The modeling was initiated with a kinematic analysis of the rotary engine. Next a modern internal combustion engine analysis code was altered for use in a rotary engine to allow the calculation of the internal combustion pressure as a function of rotor rotation. Finally the forces from the spring, inertial, and combustion pressure on the seal were combined to provide the frictional horsepower assessment.

  7. Competition and Cooperation of Distributed Generation and Power System

    NASA Astrophysics Data System (ADS)

    Miyake, Masatoshi; Nanahara, Toshiya

    Advances in distributed generation technologies together with the deregulation of an electric power industry can lead to a massive introduction of distributed generation. Since most of distributed generation will be interconnected to a power system, coordination and competition between distributed generators and large-scale power sources would be a vital issue in realizing a more desirable energy system in the future. This paper analyzes competitions between electric utilities and cogenerators from the viewpoints of economic and energy efficiency based on the simulation results on an energy system including a cogeneration system. First, we examine best response correspondence of an electric utility and a cogenerator with a noncooperative game approach: we obtain a Nash equilibrium point. Secondly, we examine the optimum strategy that attains the highest social surplus and the highest energy efficiency through global optimization.

  8. Space station automation of common module power management and distribution

    NASA Technical Reports Server (NTRS)

    Miller, W.; Jones, E.; Ashworth, B.; Riedesel, J.; Myers, C.; Freeman, K.; Steele, D.; Palmer, R.; Walsh, R.; Gohring, J.

    1989-01-01

    The purpose is to automate a breadboard level Power Management and Distribution (PMAD) system which possesses many functional characteristics of a specified Space Station power system. The automation system was built upon 20 kHz ac source with redundancy of the power buses. There are two power distribution control units which furnish power to six load centers which in turn enable load circuits based upon a system generated schedule. The progress in building this specified autonomous system is described. Automation of Space Station Module PMAD was accomplished by segmenting the complete task in the following four independent tasks: (1) develop a detailed approach for PMAD automation; (2) define the software and hardware elements of automation; (3) develop the automation system for the PMAD breadboard; and (4) select an appropriate host processing environment.

  9. Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution

    SciTech Connect

    Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

    2010-04-30

    Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

  10. Pressure Loss Modulus for correlation of steady-state {Delta}P across uniformly distributed-loss devices

    SciTech Connect

    Nunz, G.J.

    1993-10-01

    A dimensionless group, called a Pressure Loss Modulus (N{sub PL}), is introduced which, in conjunction with an appropriately defined Reynolds number, is of considerable engineering utility in correlating steady-state {Delta}P vs. flow calibration data and subsequently as a predictor, using the same or a different fluid, in uniformly distributed pressure loss devices. It is particularly useful under operation in the transition regime. Applications of this simple bivariate correlation to three diverse devices of particular interest for small liquid rocket engine fluid systems are discussed: large L/D capillary tube restrictors; packed granular catalyst beds; and stacked vortex-loss disc restrictors.

  11. The integration of renewable energy sources into electric power distribution systems. Volume 1: National assessment

    SciTech Connect

    Barnes, P.R.; Van Dyke, J.W.; Tesche, F.M.; Zaininger, H.W.

    1994-06-01

    Renewable energy technologies such as photovoltaic, solar thermal electricity, and wind turbine power are environmentally beneficial sources of electric power generation. The integration of renewable energy sources into electric power distribution systems can provide additional economic benefits because of a reduction in the losses associated with transmission and distribution lines. Benefits associated with the deferment of transmission and distribution investment may also be possible for cases where there is a high correlation between peak circuit load and renewable energy electric generation, such as photovoltaic systems in the Southwest. Case studies were conducted with actual power distribution system data for seven electric utilities with the participation of those utilities. Integrating renewable energy systems into electric power distribution systems increased the value of the benefits by about 20 to 55% above central station benefits in the national regional assessment. In the case studies presented in Vol. II, the range was larger: from a few percent to near 80% for a case where costly investments were deferred. In general, additional savings of at least 10 to 20% can be expected by integrating at the distribution level. Wind energy systems were found to be economical in good wind resource regions, whereas photovoltaic systems costs are presently a factor of 2.5 too expensive under the most favorable conditions.

  12. Optimal load distribution between units in a power plant.

    PubMed

    Bortoni, Edson C; Bastos, Guilherme S; Souza, Luiz E

    2007-10-01

    This paper presents a strategy for load distribution between the generating units in hydro power plants. The objective is to reach the maximum energy conversion efficiency for a given dispatched power. The developed tool employs a heuristic-based combinatorial optimization technique in conjunction with a set of system variables measurement allowing real-time load sharing. The developed equipment is used to give online energy conversion efficiency from each unit of the power plant. No specific previous information about the efficiency of system components is required. Simulation results of the proposed optimization technique when applied to typical hydro power plant data are presented.

  13. An Encoding Technique for Multiobjective Evolutionary Algorithms Applied to Power Distribution System Reconfiguration

    PubMed Central

    Guardado, J. L.; Rivas-Davalos, F.; Torres, J.; Maximov, S.; Melgoza, E.

    2014-01-01

    Network reconfiguration is an alternative to reduce power losses and optimize the operation of power distribution systems. In this paper, an encoding scheme for evolutionary algorithms is proposed in order to search efficiently for the Pareto-optimal solutions during the reconfiguration of power distribution systems considering multiobjective optimization. The encoding scheme is based on the edge window decoder (EWD) technique, which was embedded in the Strength Pareto Evolutionary Algorithm 2 (SPEA2) and the Nondominated Sorting Genetic Algorithm II (NSGA-II). The effectiveness of the encoding scheme was proved by solving a test problem for which the true Pareto-optimal solutions are known in advance. In order to prove the practicability of the encoding scheme, a real distribution system was used to find the near Pareto-optimal solutions for different objective functions to optimize. PMID:25401144

  14. An encoding technique for multiobjective evolutionary algorithms applied to power distribution system reconfiguration.

    PubMed

    Guardado, J L; Rivas-Davalos, F; Torres, J; Maximov, S; Melgoza, E

    2014-01-01

    Network reconfiguration is an alternative to reduce power losses and optimize the operation of power distribution systems. In this paper, an encoding scheme for evolutionary algorithms is proposed in order to search efficiently for the Pareto-optimal solutions during the reconfiguration of power distribution systems considering multiobjective optimization. The encoding scheme is based on the edge window decoder (EWD) technique, which was embedded in the Strength Pareto Evolutionary Algorithm 2 (SPEA2) and the Nondominated Sorting Genetic Algorithm II (NSGA-II). The effectiveness of the encoding scheme was proved by solving a test problem for which the true Pareto-optimal solutions are known in advance. In order to prove the practicability of the encoding scheme, a real distribution system was used to find the near Pareto-optimal solutions for different objective functions to optimize.

  15. Maximum Beam Power and Nominal Beam Losses at S-20

    SciTech Connect

    Clendenin, J.

    2005-01-31

    The maximum credible beam power values for electrons shown in Table 1 for e{sup -} beams are based on a beam power of 1.8 MW (1.875 x 10{sup 12} e{sup -} at 120 Hz) for an energy of 50 GeV at S-30. Positrons are limited by the positron source damage threshold to an average current of {approx}2 {mu}A, i.e., {approx}10{sup 11} e{sup -} per pulse at 120 Hz on the target [1]. The ratio of e{sup +} at S-1 per e{sup -} on the conversion target is {ge}2. At S-20 the maximum linac energy is 33 GeV, while the HER and LER Bypass beams are limited to 12 and 4 GeV respectively by the BCS.

  16. Optimal Operation of Energy Storage in Power Transmission and Distribution

    NASA Astrophysics Data System (ADS)

    Akhavan Hejazi, Seyed Hossein

    In this thesis, we investigate optimal operation of energy storage units in power transmission and distribution grids. At transmission level, we investigate the problem where an investor-owned independently-operated energy storage system seeks to offer energy and ancillary services in the day-ahead and real-time markets. We specifically consider the case where a significant portion of the power generated in the grid is from renewable energy resources and there exists significant uncertainty in system operation. In this regard, we formulate a stochastic programming framework to choose optimal energy and reserve bids for the storage units that takes into account the fluctuating nature of the market prices due to the randomness in the renewable power generation availability. At distribution level, we develop a comprehensive data set to model various stochastic factors on power distribution networks, with focus on networks that have high penetration of electric vehicle charging load and distributed renewable generation. Furthermore, we develop a data-driven stochastic model for energy storage operation at distribution level, where the distribution of nodal voltage and line power flow are modelled as stochastic functions of the energy storage unit's charge and discharge schedules. In particular, we develop new closed-form stochastic models for such key operational parameters in the system. Our approach is analytical and allows formulating tractable optimization problems. Yet, it does not involve any restricting assumption on the distribution of random parameters, hence, it results in accurate modeling of uncertainties. By considering the specific characteristics of random variables, such as their statistical dependencies and often irregularly-shaped probability distributions, we propose a non-parametric chance-constrained optimization approach to operate and plan energy storage units in power distribution girds. In the proposed stochastic optimization, we consider

  17. The Effects of Transients on Photospheric and Chromospheric Power Distributions

    NASA Astrophysics Data System (ADS)

    Samanta, T.; Henriques, V. M. J.; Banerjee, D.; Krishna Prasad, S.; Mathioudakis, M.; Jess, D.; Pant, V.

    2016-09-01

    We have observed a quiet-Sun region with the Swedish 1 m Solar Telescope equipped with the CRISP Imaging SpectroPolarimeter. High-resolution, high-cadence, Hα line scanning images were taken to observe different layers of the solar atmosphere from the photosphere to upper chromosphere. We study the distribution of power in different period bands at different heights. Power maps of the upper photosphere and the lower chromosphere show suppressed power surrounding the magnetic-network elements, known as “magnetic shadows.” These also show enhanced power close to the photosphere, traditionally referred to as “power halos.” The interaction between acoustic waves and inclined magnetic fields is generally believed to be responsible for these two effects. In this study we explore whether small-scale transients can influence the distribution of power at different heights. We show that the presence of transients, like mottles, Rapid Blueshifted Excursions (RBEs), and Rapid Redshifted Excursions (RREs), can strongly influence the power maps. The short and finite lifetime of these events strongly affects all power maps, potentially influencing the observed power distribution. We show that Doppler-shifted transients like RBEs and RREs that occur ubiquitously can have a dominant effect on the formation of the power halos in the quiet Sun. For magnetic shadows, transients like mottles do not seem to have a significant effect on the power suppression around 3 minutes, and wave interaction may play a key role here. Our high-cadence observations reveal that flows, waves, and shocks manifest in the presence of magnetic fields to form a nonlinear magnetohydrodynamic system.

  18. Optimization of magnetic neurostimulation waveforms for minimum power loss.

    PubMed

    Goetz, S M; Truong, N C; Gerhofer, M G; Peterchev, A V; Herzog, H-G; Weyh, T

    2012-01-01

    Magnetic stimulation is a key tool in experimental brain research and several clinical applications. Whereas coil designs and the spatial field properties have been intensively studied in the literature, the temporal dynamics of the field has received little attention. The available pulse shapes are typically determined by the relatively limited capabilities of commercial stimulation devices instead of efficiency or optimality. Furthermore, magnetic stimulation is relatively inefficient with respect to the required energy compared to other neurostimulation techniques. We therefore analyze and optimize the waveform dynamics with a nonlinear model of a mammalian motor axon for the first time, without any pre-definition of waveform candidates. We implemented an unbiased and stable numerical algorithm using variational calculus in combination with a global optimization method. This approach yields very stable results with comprehensible characteristic properties, such as a first phase which reduces ohmic losses in the subsequent pulse phase. We compare the energy loss of these optimal waveforms with the waveforms generated by existing magnetic stimulation devices.

  19. Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

    SciTech Connect

    Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

    2012-07-01

    The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

  20. Historic distribution and recent loss of tigers in China.

    PubMed

    Kang, Aili; Xie, Yan; Tang, Jirong; Sanderson, Eric W; Ginsberg, Joshua R; Zhang, Endi

    2010-12-01

    Historical records can provide important evidence of changes in distributions of wildlife species. Here we discuss the distribution of the tiger (Panthera tigris Linnaeus, 1758) over the past 2000 years in China based on 2635 historical records. We also compare tiger distributions outlined in these records with ecosystem type maps. Throughout this time period, tigers maintained a broad distribution across 7 biomes (from forests to deserts). However, in recent decades the range has been significantly condensed. Today, only 2 populations remain, neither of which is independently viable. Tigers have completely disappeared from the temperate broadleaf and mixed forests of central China, a region that was traditionally their most important biome in China. The continued presence of wild tigers in China is highly dependent on significant conservation measures. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  1. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

    NASA Technical Reports Server (NTRS)

    Schmeckpeper, K. R.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

  2. Power laws, discontinuities and regional city size distributions

    USGS Publications Warehouse

    Garmestani, A.S.; Allen, C.R.; Gallagher, C.M.

    2008-01-01

    Urban systems are manifestations of human adaptation to the natural environment. City size distributions are the expression of hierarchical processes acting upon urban systems. In this paper, we test the entire city size distributions for the southeastern and southwestern United States (1990), as well as the size classes in these regions for power law behavior. We interpret the differences in the size of the regional city size distributions as the manifestation of variable growth dynamics dependent upon city size. Size classes in the city size distributions are snapshots of stable states within urban systems in flux. ?? 2008.

  3. Forty-seventh annual power distribution conference, 1994

    SciTech Connect

    Not Available

    1994-01-01

    This is a collection of papers presented at the forty-seventh annual Power Distribution Conference in 1994. The topics of the papers include recent developments in distribution grounding, partial discharge analysis of electrical machinery, insulating fluids analysis as a basis for a complete transformer monitoring program, environmental and regulatory issues regarding the use of silicone transformer fluids, locating and identifying harmonic sources, optimizing distribution operations resources, surface launch directional boring units, electrical supply to Dallas/Fort Worth international airport, a microprocessor-based digital feeder monitor with high-impedance fault detection, a modern review of distribution system protective coordination, and Ski Apache electric service improvements.

  4. Power-law tails in the distribution of order imbalance

    NASA Astrophysics Data System (ADS)

    Zhang, Ting; Gu, Gao-Feng; Xu, Hai-Chuan; Xiong, Xiong; Chen, Wei; Zhou, Wei-Xing

    2017-10-01

    We investigate the probability distribution of order imbalance calculated from the order flow data of 43 Chinese stocks traded on the Shenzhen Stock Exchange. Two definitions of order imbalance are considered based on the order number and the order size. We find that the order imbalance distributions of individual stocks have power-law tails. However, the tail index fluctuates remarkably from stock to stock. We also investigate the distributions of aggregated order imbalance of all stocks at different timescales Δt. We find no clear trend in the tail index with respect Δt. All the analyses suggest that the distributions of order imbalance are asymmetric.

  5. Edge effect on the power law distribution of granular avalanches.

    PubMed

    Lorincz, Kinga A; Wijngaarden, Rinke J

    2007-10-01

    Many punctuated phenomena in nature are claimed [e.g., by the theory of self-organized criticality (SOC)] to be power-law distributed. In our experiments on a three-dimensional pile of long-grained rice, we find that by only changing the boundary condition of the system, we switch from such power-law-distributed avalanche sizes to quasiperiodic system-spanning avalanches. Conversely, by removing ledges the incidence of system-spanning avalanches is significantly reduced. This may offer a perspective on new avalanche prevention schemes. In addition, our findings may help to explain why the archetype of SOC, the sandpile, was found to have power-law-distributed avalanches in some experiments, while in other experiments quasiperiodic system-spanning avalanches were found.

  6. Power losses in PWM-VSI inverter using NPT or PT IGBT devices

    SciTech Connect

    Blaabjerg, F.; Munk-Nielsen, S.; Pedersen, J.K.; Jaeger, U.

    1995-05-01

    This paper investigates the power losses for two different IGBT technologies (Non Punch Through and Punch Through) for use in PWM-VSI inverters in order to choose the right device technology for a given application. A loss model of the inverter is developed based on experimental determination of the power losses. The loss model is used on two different modulation strategies which are a sine wave with a third harmonic added and a 60{degree}-PWM modulation where only two inverterlegs are active at the same time. The two IGBT technologies are characterized on an advanced measurement system which is described. The total power losses in the inverter are estimated simulation at different conditions and it is concluded that the Non Punch Through technology is most useful for higher switching frequencies, while the Punch Through technology is special useful at lower switching frequencies and high load currents. It is also concluded the 60{degree}-PWM modulation has the lowest power losses and the power losses are almost independent of phase angle cos({phi}) for normal motor operation.

  7. Benefits of Power Electronic Interfaces for Distributed Energy Systems

    SciTech Connect

    Kroposki, B.; Pink, C.; DeBlasio, R.; Thomas, H.; Simoes, M.; Sen, P. K.

    2006-01-01

    Optimization of overall electrical system performance is important for the long-term economic viability of distributed energy (DE) systems. With the increasing use of DE systems in industry and its technological advancement, it is becoming more important to understand the integration of these systems with the electric power systems. New markets and benefits for distributed energy applications include the ability to provide ancillary services, improve energy efficiency, enhance power system reliability, and allow customer choice. Advanced power electronic (PE) interfaces will allow DE systems to provide increased functionality through improved power quality and voltage/VAR support, increase electrical system compatibility by reducing the fault contributions, and flexibility in operations with various other DE sources, while reducing overall interconnection costs. This paper examines the system integration and optimization issues associated with DE systems and show the benefits of using PE interfaces for such applications.

  8. Evaluation of power control concepts using the PMAD systems test bed. [Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Beach, R. F.; Kimnach, G. L.; Jett, T. A.; Trash, L. M.

    1989-01-01

    The Lewis Research Center's Power Management and Distribution (PMAD) System testbed and its use in the evaluation of control concepts applicable to the NASA Space Station Freedom electric power system (EPS) are described. The facility was constructed to allow testing of control hardware and software in an environment functionally similar to the space station electric power system. Control hardware and software have been developed to allow operation of the testbed power system in a manner similar to a supervisory control and data acquisition (SCADA) system employed by utility power systems for control. The system hardware and software are described.

  9. Evaluation of power control concepts using the PMAD systems test bed. [Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Beach, R. F.; Kimnach, G. L.; Jett, T. A.; Trash, L. M.

    1989-01-01

    The Lewis Research Center's Power Management and Distribution (PMAD) System testbed and its use in the evaluation of control concepts applicable to the NASA Space Station Freedom electric power system (EPS) are described. The facility was constructed to allow testing of control hardware and software in an environment functionally similar to the space station electric power system. Control hardware and software have been developed to allow operation of the testbed power system in a manner similar to a supervisory control and data acquisition (SCADA) system employed by utility power systems for control. The system hardware and software are described.

  10. Does caval aplanarity influence power losses across in vitro cavopulmonary connections?

    PubMed

    Gerdes, A; Hanke, T; Ahrens, V; Pfister, G; Sievers, H-H

    2002-01-01

    Optimally designed cavopulmonary connections are desirable to reduce transanastomotic power loss. Since aplanarity of the total cavopulmonary connections results from the natural anterior-posterior position of the superior vena cava and the right pulmonary artery, the aim of this study was to investigate the influence of aplanarity of caval offset on transanastomotic power losses. Two types of cavopulmonary connections, a planar cross-like connection and a nonplanar V-shaped anastomosis, were studied in a mock circulation, comparing for each type native porcine vessels and Perspex glass models. Total flow varied between 1200 and 6000 ml/min at superior to inferior caval flow ratios of SVC/IVC = 50/50% and 33/67%, respectively. Pressures and flows were measured and power losses calculated. No significant differences in power losses were found between the planar and aplanar connections for native vessels or for Perspex glass models. Power losses across the native preparations in each configuration were significantly higher than those in the corresponding Perspex glass model. The simulation of the natural aplanar V-shaped caval offset in total cavopulmonary connections used to bypass the right ventricle seems to have no relevant additional effect on in vitro power losses compared to planar connections.

  11. Optimal reactive power planning for distribution systems considering intermittent wind power using Markov model and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Li, Cheng

    Wind farms, photovoltaic arrays, fuel cells, and micro-turbines are all considered to be Distributed Generation (DG). DG is defined as the generation of power which is dispersed throughout a utility's service territory and either connected to the utility's distribution system or isolated in a small grid. This thesis addresses modeling and economic issues pertaining to the optimal reactive power planning for distribution system with wind power generation (WPG) units. Wind farms are inclined to cause reverse power flows and voltage variations due to the random-like outputs of wind turbines. To deal with this kind of problem caused by wide spread usage of wind power generation, this thesis investigates voltage and reactive power controls in such a distribution system. Consequently static capacitors (SC) and transformer taps are introduced into the system and treated as controllers. For the purpose of getting optimum voltage and realizing reactive power control, the research proposes a proper coordination among the controllers like on-load tap changer (OLTC), feeder-switched capacitors. What's more, in order to simulate its uncertainty, the wind power generation is modeled by the Markov model. In that way, calculating the probabilities for all the scenarios is possible. Some outputs with consecutive and discrete values have been used for transition between successive time states and within state wind speeds. The thesis will describe the method to generate the wind speed time series from the transition probability matrix. After that, utilizing genetic algorithm, the optimal locations of SCs, the sizes of SCs and transformer taps are determined so as to minimize the cost or minimize the power loss, and more importantly improve voltage profiles. The applicability of the proposed method is verified through simulation on a 9-bus system and a 30-bus system respectively. At last, the simulation results indicate that as long as the available capacitors are able to sufficiently

  12. Electrical Power Distribution and Control Modeling and Analysis

    NASA Technical Reports Server (NTRS)

    Fu, Johnny S.; Liffring, Mark; Mehdi, Ishaque S.

    2001-01-01

    This slide presentation reviews the use of Electrical Power Distribution and Control (EPD&C) Modeling and how modeling can support analysis. The presentation discusses using the EASY5 model to simulate and analyze the Space Shuttle Electric Auxiliary Power Unit. Diagrams of the model schematics are included, as well as graphs of the battery cell impedance, hydraulic load dynamics, and EPD&C response to hydraulic load variations.

  13. Power optimization of random distributed feedback fiber lasers.

    PubMed

    Vatnik, Ilya D; Churkin, Dmitry V; Babin, Sergey A

    2012-12-17

    We present a comprehensive study of power output characteristics of random distributed feedback Raman fiber lasers. The calculated optimal slope efficiency of the backward wave generation in the one-arm configuration is shown to be as high as ~90% for 1 W threshold. Nevertheless, in real applications a presence of a small reflection at fiber ends can appreciably deteriorate the power performance. The developed numerical model well describes the experimental data.

  14. System-wide power management control via clock distribution network

    DOEpatents

    Coteus, Paul W.; Gara, Alan; Gooding, Thomas M.; Haring, Rudolf A.; Kopcsay, Gerard V.; Liebsch, Thomas A.; Reed, Don D.

    2015-05-19

    An apparatus, method and computer program product for automatically controlling power dissipation of a parallel computing system that includes a plurality of processors. A computing device issues a command to the parallel computing system. A clock pulse-width modulator encodes the command in a system clock signal to be distributed to the plurality of processors. The plurality of processors in the parallel computing system receive the system clock signal including the encoded command, and adjusts power dissipation according to the encoded command.

  15. Experimental quantum key distribution with simulated ground-to-satellite photon losses and processing limitations

    NASA Astrophysics Data System (ADS)

    Bourgoin, Jean-Philippe; Gigov, Nikolay; Higgins, Brendon L.; Yan, Zhizhong; Meyer-Scott, Evan; Khandani, Amir K.; Lütkenhaus, Norbert; Jennewein, Thomas

    2015-11-01

    Quantum key distribution (QKD) has the potential to improve communications security by offering cryptographic keys whose security relies on the fundamental properties of quantum physics. The use of a trusted quantum receiver on an orbiting satellite is the most practical near-term solution to the challenge of achieving long-distance (global-scale) QKD, currently limited to a few hundred kilometers on the ground. This scenario presents unique challenges, such as high photon losses and restricted classical data transmission and processing power due to the limitations of a typical satellite platform. Here we demonstrate the feasibility of such a system by implementing a QKD protocol, with optical transmission and full post-processing, in the high-loss regime using minimized computing hardware at the receiver. Employing weak coherent pulses with decoy states, we demonstrate the production of secure key bits at up to 56.5 dB of photon loss. We further illustrate the feasibility of a satellite uplink by generating a secure key while experimentally emulating the varying losses predicted for realistic low-Earth-orbit satellite passes at 600 km altitude. With a 76 MHz source and including finite-size analysis, we extract 3374 bits of a secure key from the best pass. We also illustrate the potential benefit of combining multiple passes together: while one suboptimal "upper-quartile" pass produces no finite-sized key with our source, the combination of three such passes allows us to extract 165 bits of a secure key. Alternatively, we find that by increasing the signal rate to 300 MHz it would be possible to extract 21 570 bits of a secure finite-sized key in just a single upper-quartile pass.

  16. DETERMINATION OF INVENTORIES AND POWER DISTRIBUTIONS FOR THE NSBR.

    SciTech Connect

    HANSON, A.L.; DIAMOND, D.J.

    2005-09-12

    This memo presents the details of the methodology for developing fuel inventories for the NBSR along with power distributions predicted with this set of inventories. Several improvements have been made to the MCNP model of the NBSR since a set of calculations was performed in 2002 in support of the NBSR relicensing and SAR update. One of the most significant changes in the model was to divide the fuel elements into upper and lower halves so the effects of uneven burn between the two halves (due to the shim arms) can be determined. The present set of power distributions are provided for comparison with the previous safety analyses.

  17. Impact of distributed power electronics on the lifetime and reliability of PV systems: Impact of distributed power electronics

    DOE PAGES

    Olalla, Carlos; Maksimovic, Dragan; Deline, Chris; ...

    2017-04-26

    Here, this paper quantifies the impact of distributed power electronics in photovoltaic (PV) systems in terms of end-of-life energy-capture performance and reliability. The analysis is based on simulations of PV installations over system lifetime at various degradation rates. It is shown how module-level or submodule-level power converters can mitigate variations in cell degradation over time, effectively increasing the system lifespan by 5-10 years compared with the nominal 25-year lifetime. An important aspect typically overlooked when characterizing such improvements is the reliability of distributed power electronics, as power converter failures may not only diminish energy yield improvements but also adversely affectmore » the overall system operation. Failure models are developed, and power electronics reliability is taken into account in this work, in order to provide a more comprehensive view of the opportunities and limitations offered by distributed power electronics in PV systems. Lastly, it is shown how a differential power-processing approach achieves the best mismatch mitigation performance and the least susceptibility to converter faults.« less

  18. Distribution-Agnostic Stochastic Optimal Power Flow for Distribution Grids: Preprint

    SciTech Connect

    Baker, Kyri; Dall'Anese, Emiliano; Summers, Tyler

    2016-09-01

    This paper outlines a data-driven, distributionally robust approach to solve chance-constrained AC optimal power flow problems in distribution networks. Uncertain forecasts for loads and power generated by photovoltaic (PV) systems are considered, with the goal of minimizing PV curtailment while meeting power flow and voltage regulation constraints. A data- driven approach is utilized to develop a distributionally robust conservative convex approximation of the chance-constraints; particularly, the mean and covariance matrix of the forecast errors are updated online, and leveraged to enforce voltage regulation with predetermined probability via Chebyshev-based bounds. By combining an accurate linear approximation of the AC power flow equations with the distributionally robust chance constraint reformulation, the resulting optimization problem becomes convex and computationally tractable.

  19. Electric power scheduling - A distributed problem-solving approach

    NASA Technical Reports Server (NTRS)

    Mellor, Pamela A.; Dolce, James L.; Krupp, Joseph C.

    1990-01-01

    Space Station Freedom's power system, along with the spacecraft's other subsystems, needs to carefully conserve its resources and yet strive to maximize overall Station productivity. Due to Freedom's distributed design, each subsystem must work cooperatively within the Station community. There is a need for a scheduling tool which will preserve this distributed structure, allow each subsystem the latitude to satisfy its own constraints, and preserve individual value systems while maintaining Station-wide integrity.

  20. Power law distribution of dividends in horse races

    NASA Astrophysics Data System (ADS)

    Park, K.; Domany, E.

    2001-02-01

    We discovered that the distribution of dividends in Korean horse races follows a power law. A simple model of betting is proposed, which reproduces the observed distribution. The model provides a mechanism to arrive at the true underlying winning probabilities, which are initially unknown, in a self-organized collective fashion, through the dynamic process of betting. Numerical simulations yield excellent agreement with the empirical data.

  1. Wind Power Forecasting Error Distributions: An International Comparison; Preprint

    SciTech Connect

    Hodge, B. M.; Lew, D.; Milligan, M.; Holttinen, H.; Sillanpaa, S.; Gomez-Lazaro, E.; Scharff, R.; Soder, L.; Larsen, X. G.; Giebel, G.; Flynn, D.; Dobschinski, J.

    2012-09-01

    Wind power forecasting is expected to be an important enabler for greater penetration of wind power into electricity systems. Because no wind forecasting system is perfect, a thorough understanding of the errors that do occur can be critical to system operation functions, such as the setting of operating reserve levels. This paper provides an international comparison of the distribution of wind power forecasting errors from operational systems, based on real forecast data. The paper concludes with an assessment of similarities and differences between the errors observed in different locations.

  2. Power-law distribution of family names in Japanese societies

    NASA Astrophysics Data System (ADS)

    Miyazima, Sasuke; Lee, Youngki; Nagamine, Tomomasa; Miyajima, Hiroaki

    2000-04-01

    We study the frequency distribution of family names. From a common data base, we count the number of people who share the same family name. This is the size of the family. We find that (i) the total number of different family names in a society scales as a power law of the population, (ii) the total number of family names of the same size decreases as the size increases with a power law and (iii) the relation between size and rank of a family name also shows a power law. These scaling properties are found to be consistent for five different regional communities in Japan.

  3. Load Frequency Control in Power System with Distributed Generation

    NASA Astrophysics Data System (ADS)

    Yukita, Kazuto; Ota, Takuya; Fujimoto, Koji; Goto, Yasuyuki; Ichiyanagi, Katuhiro

    This paper proposes a method to improve the load frequency control in a power system with distributed generation (DG). DG is assumed to include photovoltaic generation, wind power generation, fuel cells and etc. In this paper, a simulation is performed using a microgrid model or island model that is composed of a storage system with either wind power generation or photovoltaic generation system as the DG. The effectiveness of load frequency control (LFC) using a storage system is examined using a power transmission simulator. The model for the experiment has been composed of inverter, battery, synchronous generator and load. Using this model, the comparison examination was done in respect of output setting control and the case in which the PI control was used. As a result, when the output set-point control using power demand estimation method is executed, the control characteristic is very excellent.

  4. A Distributed Cooperative Power Allocation Method for Campus Buildings

    SciTech Connect

    Hao, He; Sun, Yannan; Carroll, Thomas E.; Somani, Abhishek

    2015-09-01

    We propose a coordination algorithm for cooperative power allocation among a collection of commercial buildings within a campus. We introduced thermal and power models of a typical commercial building Heating, Ventilation, and Air Conditioning (HVAC) system, and utilize model predictive control to characterize their power flexibility. The power allocation problem is formulated as a cooperative game using the Nash Bargaining Solution (NBS) concept, in which buildings collectively maximize the product of their utilities subject to their local flexibility constraints and a total power limit set by the campus coordinator. To solve the optimal allocation problem, a distributed protocol is designed using dual decomposition of the Nash bargaining problem. Numerical simulations are performed to demonstrate the efficacy of our proposed allocation method

  5. Spectrum bias and loss of statistical power in discordant couple studies of sexually transmitted infections.

    PubMed

    Tuite, Ashleigh R; Fisman, David N

    2011-01-01

    Discordant couple studies are frequently used to evaluate preventive interventions for sexually transmitted infections (STI). This study design may be vulnerable to spectrum bias when transmission risk is heterogeneous. We used Markov models to assess the effect of heterogeneous transmission risk on the ability to detect effective interventions using a discordant couple study design. We also evaluated the implications that such bias may have for statistical power. Models incorporated potential health states in a population of initially infection-discordant couples, according to infection status with a hypothetical STI and participation in a hypothetical clinical research study. We evaluated the effect of length of discordant relationship at time of study enrollment, the shape of distribution describing transmission risk among couples, and the effect of sex-specific differential transmission probabilities, on model outcomes. The results demonstrate that discordant couple studies are prone to spectrum bias, the degree of which is affected by the shape of the underlying transmission probability density function. Such bias could lead to unexpected study findings, including gender-specific vaccine effects, and loss of statistical power, making this an important and underrecognized consideration in the design and interpretation of discordant couple studies.

  6. Accumulation, loss and molecular distribution of cadmium in Mytilus edulis

    NASA Astrophysics Data System (ADS)

    Scholz, N.

    1980-03-01

    In Mytilus edulis, accumulation and loss of Cd were analyzed under experimental conditions. Cd uptake by the whole soft body is linear, increasing significantly with increasing Cd concentrations in the uptake medium. Until 100 µg Cd l-1, neither limitation of uptake nor any saturation process can be observed. Loss of Cd, measured after transfer of experimentally contaminated mussels to natural sea water, is exponential; biological half lives vary between 14 and 29 days. Gills are the primary sites of Cd uptake from the water, whereas in mid-gut gland, kidney, and mantle the uptake is retarded during the first few days. The mid-gut gland not only bears the main body load of Cd, but also shows the highest Cd concentrations. Gel chromatographic studies of mid-gut gland proteins reveal that Cd is eluated over the whole molecular weight range. Three metallothionein-like proteins with molecular weights of 6,600, 13,200, and 21,000 Dalton could be established. However, they cannot be taken as effective detoxification proteins, because more than 50% of the accumulated metal is bound to high molecular weight proteins.

  7. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2012-02-15

    We investigated the ion-loss distribution on the sidewall of an electron cyclotron resonance (ECR) plasma chamber using the 18-GHz ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex (TRIAC). Similarities and differences between the ion-loss distributions (longitudinal and azimuthal) of different ion species (i.e., radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions that are typical volatile and nonvolatile elements) was qualitatively discussed to understand the element dependence of the charge breeding efficiency. Especially, the similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  8. Analysis of axially non-uniform loss distribution in 3-phase induction motor considering skew effect

    SciTech Connect

    Kown, B.I.; Kim, B.T.; Jun, C.S.; Park, S.C. )

    1999-05-01

    This paper discusses the phenomena of the axially non-uniform distribution of magnetic flux densities and losses in a 3-phase squirrel cage induction motor of which the rotor bars are skewed. A 2-dimensional complex finite element method taking account of the effects of the skewed rotor bars is utilized for the analysis of characteristics such as copper and iron losses and the loss distributions are examined. The summing up values of non-uniform losses resulted from the finite element analysis are compared with measurement values.

  9. Minimization of the Ohmic Loss of Grooved Polarizer Mirrors in High-Power ECRH Systems

    NASA Astrophysics Data System (ADS)

    Wagner, D.; Leuterer, F.; Kasparek, W.; Stober, J.

    2017-02-01

    A set of two corrugated polarizer mirrors is typically used in high-power electron cyclotron resonance heating (ECRH) systems to provide the required polarization of the ECRH output beam. The ohmic losses of these mirrors can significantly exceed the losses of plane mirrors depending on the polarization of the incident beam with respect to the orientation of the grooves. Since polarizer mirrors incorporated into miter bends of a corrugated waveguide line are limited in size, active water cooling can become critical in high-power cw systems like the one for ITER. The ohmic loss of polarizer mirrors has been investigated experimentally at high power. A strategy to minimize the losses for given mirror geometries has been found.

  10. Low-Loss Transmission Lines for High-Power Terahertz Radiation

    PubMed Central

    Nanni, Emilio A.; Jawla, Sudheer K.; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-01-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends. PMID:23162673

  11. Low-Loss Transmission Lines for High-Power Terahertz Radiation.

    PubMed

    Nanni, Emilio A; Jawla, Sudheer K; Shapiro, Michael A; Woskov, Paul P; Temkin, Richard J

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE(11) mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE(11) mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE(11) mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends.

  12. Low-loss Transmission Lines for High-power Terahertz Radiation

    NASA Astrophysics Data System (ADS)

    Nanni, Emilio Alessandro; Jawla, Sudheer Kumar; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends.

  13. Accuracy of telemetry signal power loss in a filter as an estimate for telemetry degradation

    NASA Astrophysics Data System (ADS)

    Koerner, M. A.

    1989-05-01

    When telemetry data is transmitted through a communication link, some degradation in telemetry performance occurs as a result of the imperfect frequency response of the channel. The term telemetry degradation as used here is the increase in received signal power required to offset this filtering. The usual approach to assessing this degradation is to assume that it is equal to the signal power loss in the filtering, which is easily calculated. However, this approach neglects the effects of the nonlinear phase response of the filter, the effect of any reduction of the receiving system noise due to the filter, and intersymbol interference. Here, an exact calculation of the telemetry degradation, which includes all of the above effects, is compared with the signal power loss calculation for RF filtering of NRZ data on a carrier. The signal power loss calculation is found to be a reasonable approximation when the filter follows the point at which the receiving system noise is introduced, especially if the signal power loss is less than 0.5 dB. The signal power loss approximation is less valid when the receiving system noise is not filtered.

  14. Power-law time distribution of large earthquakes.

    PubMed

    Mega, Mirko S; Allegrini, Paolo; Grigolini, Paolo; Latora, Vito; Palatella, Luigi; Rapisarda, Andrea; Vinciguerra, Sergio

    2003-05-09

    We study the statistical properties of time distribution of seismicity in California by means of a new method of analysis, the diffusion entropy. We find that the distribution of time intervals between a large earthquake (the main shock of a given seismic sequence) and the next one does not obey Poisson statistics, as assumed by the current models. We prove that this distribution is an inverse power law with an exponent mu=2.06+/-0.01. We propose the long-range model, reproducing the main properties of the diffusion entropy and describing the seismic triggering mechanisms induced by large earthquakes.

  15. Integrated Computing, Communication, and Distributed Control of Deregulated Electric Power Systems

    SciTech Connect

    Bajura, Richard; Feliachi, Ali

    2008-09-24

    Restructuring of the electricity market has affected all aspects of the power industry from generation to transmission, distribution, and consumption. Transmission circuits, in particular, are stressed often exceeding their stability limits because of the difficulty in building new transmission lines due to environmental concerns and financial risk. Deregulation has resulted in the need for tighter control strategies to maintain reliability even in the event of considerable structural changes, such as loss of a large generating unit or a transmission line, and changes in loading conditions due to the continuously varying power consumption. Our research efforts under the DOE EPSCoR Grant focused on Integrated Computing, Communication and Distributed Control of Deregulated Electric Power Systems. This research is applicable to operating and controlling modern electric energy systems. The controls developed by APERC provide for a more efficient, economical, reliable, and secure operation of these systems. Under this program, we developed distributed control algorithms suitable for large-scale geographically dispersed power systems and also economic tools to evaluate their effectiveness and impact on power markets. Progress was made in the development of distributed intelligent control agents for reliable and automated operation of integrated electric power systems. The methodologies employed combine information technology, control and communication, agent technology, and power systems engineering in the development of intelligent control agents for reliable and automated operation of integrated electric power systems. In the event of scheduled load changes or unforeseen disturbances, the power system is expected to minimize the effects and costs of disturbances and to maintain critical infrastructure operational.

  16. A Wolf Pack Algorithm for Active and Reactive Power Coordinated Optimization in Active Distribution Network

    NASA Astrophysics Data System (ADS)

    Zhuang, H. M.; Jiang, X. J.

    2016-08-01

    This paper presents an active and reactive power dynamic optimization model for active distribution network (ADN), whose control variables include the output of distributed generations (DGs), charge or discharge power of energy storage system (ESS) and reactive power from capacitor banks. To solve the high-dimension nonlinear optimization model, a new heuristic swarm intelligent method, namely wolf pack algorithm (WPA) with better global convergence and computational robustness, is adapted so that the network loss minimization can be achieved. In this paper, the IEEE33-bus system is used to show the effectiveness of WPA technique compared with other techniques. Numerical tests on the modified IEEE 33-bus system show that WPA for active and reactive multi-period optimization of ADN is exact and effective.

  17. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width and ratio on total mesh power loss for a wide range of speeds, torques and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine-pitched gears had higher peak efficiencies but lower part-load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full-load loss except at low speeds.

  18. High Resolution PV Power Modeling for Distribution Circuit Analysis

    SciTech Connect

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  19. Economic growth, climate change, biodiversity loss: distributive justice for the global north and south.

    PubMed

    Rosales, Jon

    2008-12-01

    Economic growth-the increase in production and consumption of goods and services-must be considered within its biophysical context. Economic growth is fueled by biophysical inputs and its outputs degrade ecological processes, such as the global climate system. Economic growth is currently the principal cause of increased climate change, and climate change is a primary mechanism of biodiversity loss. Therefore, economic growth is a prime catalyst of biodiversity loss. Because people desire economic growth for dissimilar reasons-some for the increased accumulation of wealth, others for basic needs-how we limit economic growth becomes an ethical problem. Principles of distributive justice can help construct an international climate-change regime based on principles of equity. An equity-based framework that caps economic growth in the most polluting economies will lessen human impact on biodiversity. When coupled with a cap-and-trade mechanism, the framework can also provide a powerful tool for redistribution of wealth. Such an equity-based framework promises to be more inclusive and therefore more effective because it accounts for the disparate developmental conditions of the global north and south.

  20. Power Management and Distribution Trades Studies for a Deep-Space Mission Scientific Spacecraft

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Soltis, James V.

    2004-01-01

    As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50kWe to one half of the ion thrusters and science modules but is capable of supplying the total power re3quirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

  1. Power Management and Distribution Trades Studies for a Deep-space Mission Scientific Spacecraft

    NASA Astrophysics Data System (ADS)

    Kimnach, Greg L.; Soltis, James V.

    2004-02-01

    As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft, which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz) and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels, and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50 kWe to one-half of the ion thrusters and science modules, but is capable of supplying the total power requirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

  2. Distributed Power Flow Control: Distributed Power Flow Control using Smart Wires for Energy Routing

    SciTech Connect

    2012-04-24

    GENI Project: Smart Wire Grid is developing a solution for controlling power flow within the electric grid to better manage unused and overall transmission capacity. The 300,000 miles of high-voltage transmission line in the U.S. today are congested and inefficient, with only around 50% of all transmission capacity utilized at any given time. Increased consumer demand should be met in part with more efficient and an economical power flow. Smart Wire Grid’s devices clamp onto existing transmission lines and control the flow of power within—much like how internet routers help allocate bandwidth throughout the web. Smart wires could support greater use of renewable energy by providing more consistent control over how that energy is routed within the grid on a real-time basis. This would lessen the concerns surrounding the grid’s inability to effectively store intermittent energy from renewables for later use.

  3. Exploring empowerment in settings: mapping distributions of network power.

    PubMed

    Neal, Jennifer Watling

    2014-06-01

    This paper brings together two trends in the empowerment literature-understanding empowerment in settings and understanding empowerment as relational-by examining what makes settings empowering from a social network perspective. Specifically, extending Neal and Neal's (Am J Community Psychol 48(3/4):157-167, 2011) conception of network power, an empowering setting is defined as one in which (1) actors have existing relationships that allow for the exchange of resources and (2) the distribution of network power among actors in the setting is roughly equal. The paper includes a description of how researchers can examine distributions of network power in settings. Next, this process is illustrated in both an abstract example and using empirical data on early adolescents' peer relationships in urban classrooms. Finally, implications for theory, methods, and intervention related to understanding empowering settings are explored.

  4. Statistical Models of Power-law Distributions in Homogeneous Plasmas

    SciTech Connect

    Roth, Ilan

    2011-01-04

    A variety of in-situ measurements in space plasmas point out to an intermittent formation of distribution functions with elongated tails and power-law at high energies. Power-laws form ubiquitous signature of many complex systems, plasma being a good example of a non-Boltzmann behavior for distribution functions of energetic particles. Particles, which either undergo mutual collisions or are scattered in phase space by electromagnetic fluctuations, exhibit statistical properties, which are determined by the transition probability density function of a single interaction, while their non-asymptotic evolution may determine the observed high-energy populations. It is shown that relaxation of the Brownian motion assumptions leads to non-analytical characteristic functions and to generalization of the Fokker-Planck equation with fractional derivatives that result in power law solutions parameterized by the probability density function.

  5. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  6. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, J.W.; O`Brien, D.W.

    1996-07-09

    An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.

  7. HEMP interaction with an electric power distribution circuit. Final report

    SciTech Connect

    Zaininger, H.W.; Jaszewski, G.M.

    1985-08-01

    A high altitude nuclear burst, detonated at a height of 50 km or more, causes two types of electromagnetic pulses, high altitude EMP (HEMP) and magnetohydrodynamic EMP, which will interact with electric power systems. Previous work indicated that millions of miles of electric distribution systems in the United States may be especially vulnerable to HEMP incident simultaneously throughout large portions of the United States. Purpose of this work was to perform an initial assessment of HEMP induced surges on a simplified electric distribution system. This report presents the assumptions, methodology, and resulting induced transient voltages and currents at various points in the distribution circuit in the microsecond timeframe, considering the impacts of HEMP incident simultaneously throughout the distribution system for a range of parametric conditions. Results of this work suggest that EMP could induce voltage transients that far exceed the basic insulation level (BIL) of distribution systems and that a more detailed analysis is warranted.

  8. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a

  9. Prestorm estimation of hurricane damage to electric power distribution systems.

    PubMed

    Guikema, Seth D; Quiring, Steven M; Han, Seung-Ryong

    2010-12-01

    Hurricanes frequently cause damage to electric power systems in the United States, leading to widespread and prolonged loss of electric service. Restoring service quickly requires the use of repair crews and materials that must be requested, at considerable cost, prior to the storm. U.S. utilities have struggled to strike a good balance between over- and underpreparation largely because of a lack of methods for rigorously estimating the impacts of an approaching hurricane on their systems. Previous work developed methods for estimating the risk of power outages and customer loss of power, with an outage defined as nontransitory activation of a protective device. In this article, we move beyond these previous approaches to directly estimate damage to the electric power system. Our approach is based on damage data from past storms together with regression and data mining techniques to estimate the number of utility poles that will need to be replaced. Because restoration times and resource needs are more closely tied to the number of poles and transformers that need to be replaced than to the number of outages, this pole-based assessment provides a much stronger basis for prestorm planning by utilities. Our results show that damage to poles during hurricanes can be assessed accurately, provided that adequate past damage data are available. However, the availability of data can, and currently often is, the limiting factor in developing these types of models in practice. Opportunities for further enhancing the damage data recorded during hurricanes are also discussed.

  10. Learning geotemporal nonstationary failure and recovery of power distribution.

    PubMed

    Wei, Yun; Ji, Chuanyi; Galvan, Floyd; Couvillon, Stephen; Orellana, George; Momoh, James

    2014-01-01

    Smart energy grid is an emerging area for new applications of machine learning in a nonstationary environment. Such a nonstationary environment emerges when large-scale failures occur at power networks because of external disruptions such as hurricanes and severe storms. Power distribution networks lie at the edge of the grid, and are especially vulnerable to external disruptions. Quantifiable approaches are lacking and needed to learn nonstationary behaviors of large-scale failure and recovery of power distribution. This paper studies such nonstationary behaviors in three aspects. First, a novel formulation is derived for an entire life cycle of large-scale failure and recovery of power distribution. Second, spatial-temporal models of failure and recovery of power distribution are developed as geolocation-based multivariate nonstationary GI(t)/G(t)/∞ queues. Third, the nonstationary spatial-temporal models identify a small number of parameters to be learned. Learning is applied to two real-life examples of large-scale disruptions. One is from Hurricane Ike, where data from an operational network is exact on failures and recoveries. The other is from Hurricane Sandy, where aggregated data is used for inferring failure and recovery processes at one of the impacted areas. Model parameters are learned using real data. Two findings emerge as results of learning: 1) failure rates behave similarly at the two different provider networks for two different hurricanes but differently at the geographical regions and 2) both the rapid and slow-recovery are present for Hurricane Ike but only slow recovery is shown for a regional distribution network from Hurricane Sandy.

  11. Interacting discrete Markov processes with power-law probability distributions

    NASA Astrophysics Data System (ADS)

    Ridley, Kevin D.; Jakeman, Eric

    2017-09-01

    During recent years there has been growing interest in the occurrence of long-tailed distributions, also known as heavy-tailed or fat-tailed distributions, which can exhibit power-law behaviour and often characterise physical systems that undergo very large fluctuations. In this paper we show that the interaction between two discrete Markov processes naturally generates a time-series characterised by such a distribution. This possibility is first demonstrated by numerical simulation and then confirmed by a mathematical analysis that enables the parameter range over which the power-law occurs to be quantified. The results are supported by comparison of numerical results with theoretical predictions and general conclusions are drawn regarding mechanisms that can cause this behaviour.

  12. Multi-kw dc power distribution system study program

    NASA Technical Reports Server (NTRS)

    Berkery, E. A.; Krausz, A.

    1974-01-01

    The first phase of the Multi-kw dc Power Distribution Technology Program is reported and involves the test and evaluation of a technology breadboard in a specifically designed test facility according to design concepts developed in a previous study on space vehicle electrical power processing, distribution, and control. The static and dynamic performance, fault isolation, reliability, electromagnetic interference characterisitics, and operability factors of high distribution systems were studied in order to gain a technology base for the use of high voltage dc systems in future aerospace vehicles. Detailed technical descriptions are presented and include data for the following: (1) dynamic interactions due to operation of solid state and electromechanical switchgear; (2) multiplexed and computer controlled supervision and checkout methods; (3) pulse width modulator design; and (4) cable design factors.

  13. Technical and Economic Assessment of the Implementation of Measures for Reducing Energy Losses in Distribution Systems

    NASA Astrophysics Data System (ADS)

    Aguila, Alexander; Wilson, Jorge

    2017-07-01

    This paper develops a methodology to assess a group of measures of electrical improvements in distribution systems, starting from the complementation of technical and economic criteria. In order to solve the problem of energy losses in distribution systems, technical and economic analysis was performed based on a mathematical model to establish a direct relationship between the energy saved by way of minimized losses and the costs of implementing the proposed measures. This paper aims at analysing the feasibility of reducing energy losses in distribution systems, by changing existing network conductors by larger crosssection conductors and distribution voltage change at higher levels. The impact of this methodology provides a highly efficient mathematical tool for analysing the feasibility of implementing improvement projects based on their costs which is a very useful tool for the distribution companies that will serve as a starting point to the analysis for this type of projects in distribution systems.

  14. Improving Advanced Inverter Control Convergence in Distribution Power Flow

    SciTech Connect

    Nagarajan, Adarsh; Palmintier, Bryan; Ding, Fei; Mather, Barry; Baggu, Murali

    2016-11-21

    Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

  15. Chattanooga Electric Power Board Case Study Distribution Automation

    SciTech Connect

    Glass, Jim; Melin, Alexander M.; Starke, Michael R.

    2016-10-01

    In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities considering a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under

  16. Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm

    DOE PAGES

    Zhang, Baohua; Hu, Weihao; Hou, Peng; ...

    2017-06-27

    This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less

  17. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  18. Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer

    PubMed Central

    Tang, Sai Chun; McDannold, Nathan J.

    2015-01-01

    This paper investigated the power losses of unsegmented and segmented energy coupling coils for wireless energy transfer. Four 30-cm energy coupling coils with different winding separations, conductor cross-sectional areas, and number of turns were developed. The four coils were tested in both unsegmented and segmented configurations. The winding conduction and intrawinding dielectric losses of the coils were evaluated individually based on a well-established lumped circuit model. We found that the intrawinding dielectric loss can be as much as seven times higher than the winding conduction loss at 6.78 MHz when the unsegmented coil is tightly wound. The dielectric loss of an unsegmented coil can be reduced by increasing the winding separation or reducing the number of turns, but the power transfer capability is reduced because of the reduced magnetomotive force. Coil segmentation using resonant capacitors has recently been proposed to significantly reduce the operating voltage of a coil to a safe level in wireless energy transfer for medical implants. Here, we found that it can naturally eliminate the dielectric loss. The coil segmentation method and the power loss analysis used in this paper could be applied to the transmitting, receiving, and resonant coils in two- and four-coil energy transfer systems. PMID:26640745

  19. Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer.

    PubMed

    Tang, Sai Chun; McDannold, Nathan J

    2015-03-01

    This paper investigated the power losses of unsegmented and segmented energy coupling coils for wireless energy transfer. Four 30-cm energy coupling coils with different winding separations, conductor cross-sectional areas, and number of turns were developed. The four coils were tested in both unsegmented and segmented configurations. The winding conduction and intrawinding dielectric losses of the coils were evaluated individually based on a well-established lumped circuit model. We found that the intrawinding dielectric loss can be as much as seven times higher than the winding conduction loss at 6.78 MHz when the unsegmented coil is tightly wound. The dielectric loss of an unsegmented coil can be reduced by increasing the winding separation or reducing the number of turns, but the power transfer capability is reduced because of the reduced magnetomotive force. Coil segmentation using resonant capacitors has recently been proposed to significantly reduce the operating voltage of a coil to a safe level in wireless energy transfer for medical implants. Here, we found that it can naturally eliminate the dielectric loss. The coil segmentation method and the power loss analysis used in this paper could be applied to the transmitting, receiving, and resonant coils in two- and four-coil energy transfer systems.

  20. Power Sharing Control between Load-Side Inverters in DC Microgrid for Super High Quality Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Kakigano, Hiroaki; Nada, Kaho; Miura, Yushi; Ise, Toshifumi; Uchida, Ryohei

    DC microgrid is a novel power system using dc distribution in order to provide a super high quality electric power. The dc distribution system is suitable for dc output type distributed generations such as photovoltaic and fuel cells, and energy storages such as batteries and electric double layer capacitors. Power is distributed through dc distribution line and converted to required ac or dc voltage by converters placed near loads. Load-side single phase inverters are connected through transformers in order to share active and reactive power. In this paper, a power sharing control scheme was proposed, and the power sharing characteristics were demonstrated by experimental results.

  1. Theoretical study of pump power distribution on modal instabilities in high power fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Tao, Rumao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Liu, Zejin

    2017-02-01

    Influence of pump power distribution on modal instabilities (MI) is studied numerically, which reveals that the MI threshold is dependent on the pump power distribution in fiber amplifiers and can be increased by optimizing the pump power distribution without any adjustment of other amplifier parameters. It shows that amplifiers with backward or bi-direction pump schemes have a higher threshold than those employing forward pump schemes. For backward pumped amplifiers employing fiber with core/clad diameter being 20/400 µm, the MI threshold yields a 42% increase compared to the forward pumped ones. For bi-direction pumped amplifiers, there exists an optimal power ratio between forward and backward pump power, which results in the highest threshold power. When amplifiers with core/clad diameter being 20/400 µm employ a bi-direction pump scheme at the optimal backward pump power fraction, the threshold can be increased by a factor of approximately 60% with respect to the forward pump configuration. The threshold increment factor reduces as the gain saturation effect weakens. It also shows that the MI threshold can be increased by employing multi-point side pump schemes.

  2. Distributed renewable power from biomass and other waste fuels

    NASA Astrophysics Data System (ADS)

    Lyons, Chris

    2012-03-01

    The world population is continually growing and putting a burden on our fossil fuels. These fossil fuels such as coal, oil and natural gas are used for a variety of critical needs such as power production and transportation. While significant environmental improvements have been made, the uses of these fuels are still causing significant ecological impacts. Coal power production efficiency has not improved over the past thirty years and with relatively cheap petroleum cost, transportation mileage has not improved significantly either. With the demand for these fossil fuels increasing, ultimately price will also have to increase. This presentation will evaluate alternative power production methods using localized distributed generation from biomass, municipal solid waste and other waste sources of organic materials. The presentation will review various gasification processes that produce a synthetic gas that can be utilized as a fuel source in combustion turbines for clean and efficient combined heat and power. This fuel source can produce base load renewable power. In addition tail gases from the production of bio-diesel and methanol fuels can be used to produce renewable power. Being localized can reduce the need for long and costly transmission lines making the production of fuels and power from waste a viable alternative energy source for the future.

  3. 26 CFR 1.735-1 - Character of gain or loss on disposition of distributed property.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...—(1) Unrealized receivables. Any gain realized or loss sustained by a partner on a sale or exchange or... property other than a capital asset. (2) Inventory items. Any gain realized or loss sustained by a partner... partner of such inventory items after 5 years from the date of distribution shall be determined as of...

  4. Power-law citation distributions are not scale-free

    NASA Astrophysics Data System (ADS)

    Golosovsky, Michael

    2017-09-01

    We analyze time evolution of statistical distributions of citations to scientific papers published in the same year. While these distributions seem to follow the power-law dependence we find that they are nonstationary and the exponent of the power-law fit decreases with time and does not come to saturation. We attribute the nonstationarity of citation distributions to different longevity of the low-cited and highly cited papers. By measuring citation trajectories of papers we found that citation careers of the low-cited papers come to saturation after 10-15 years while those of the highly cited papers continue to increase indefinitely: The papers that exceed some citation threshold become runaways. Thus, we show that although citation distribution can look as a power-law dependence, it is not scale free and there is a hidden dynamic scale associated with the onset of runaways. We compare our measurements to our recently developed model of citation dynamics based on copying-redirection-triadic closure and find explanations to our empirical observations.

  5. Distribution automation field research and planning at United Power Association

    SciTech Connect

    Lebakken, T.M.; Gasal, J.; Goodin, J.L.; Nikula, R.

    1995-12-31

    United Power Association (UPA) has undertaken three concurrent efforts to set direction and test distribution automation approaches at UPA and its fifteen member distribution cooperatives. The first is a distribution automation and communications research project funded by the Electric Power Research Institute (EPRI), National Rural Electric Cooperative Association (NRECA), Rural Electric Research and United Power Association. The project advances innovative approaches to automation, such as the Utility Communications Architecture (UCA), through field implementation research. The research project goals include achieving greater plug and play between multi-vendor field devices, communication systems, databases and applications. The field research project examines and tests key concepts to lead two concurrent planning activities: a Distribution Automation Master Plan and a Telecommunications Plan. These plans will use the mid-1995 results of the research project to set the automation direction for UPA and its member cooperatives. The research project focuses on representative portions of the UPA system yet the planning studies cover the entire service territory from the Minneapolis/St. Paul suburbs to the Canadian border. This case study and panel discussion will review the implications of the research project and key aspects of the integrated automation planning projects. The panelists will reflect on their role in the projects and what other utilities may learn from these activities.

  6. Development of a bionanobattery for distributed power storage systems

    NASA Astrophysics Data System (ADS)

    King, Glen C.; Choi, Sang H.; Chu, Sang-Hyon; Kim, Jae-Woo; Park, Yeonjoon; Lillehei, Peter T.; Watt, Gerald D.; Davis, Robert C.; Harb, John N.

    2004-07-01

    Currently available power storage systems, such as those used to supply power to microelectronic devices, typically consist of a single centralized canister and a series of wires to supply electrical power to where it is needed in a circuit. As the size of electrical circuits and components become smaller, there exists a need for a distributed power system to reduce Joule heating, wiring, and to allow autonomous operation of the various functions performed by the circuit. Our research is being conducted to develop a bio-nanobattery using ferritins reconstituted with both an iron core (Fe-ferritin) and a cobalt core (Co-ferritin). Both Co-ferritin and Fe-ferritin were synthesized and characterized as candidates for the bio-nanobattery. The reducing capability was determined as well as the half-cell electrical potentials, indicating an electrical output of nearly 0.5 V for the battery cell. Ferritins having other metallic cores are also being investigated, in order to increase the overall electrical output. Two dimensional ferritin arrays were also produced on various substrates, demonstrating the necessary building blocks for the bio-nanobattery. The bio-nanobattery will play a key role in moving to a distributed power storage system for electronic applications.

  7. Deviation from power law of the global seismic moment distribution

    PubMed Central

    Serra, Isabel; Corral, Álvaro

    2017-01-01

    The distribution of seismic moment is of capital interest to evaluate earthquake hazard, in particular regarding the most extreme events. We make use of likelihood-ratio tests to compare the simple Gutenberg-Richter power-law (PL) distribution with two statistical models that incorporate an exponential tail, the so-called tapered Gutenberg-Richter (Tap) and the truncated gamma, when fitted to the global CMT earthquake catalog. Although the Tap distribution does not introduce any significant improvement of fit respect the PL, the truncated gamma does. Simulated samples of this distribution, with parameters β = 0.68 and mc = 9.15 and reshuffled in order to mimic the time occurrence of the order statistics of the empirical data, are able to explain the temporal heterogeneity of global seismicity both before and after the great Sumatra-Andaman earthquake of 2004. PMID:28053311

  8. Deviation from power law of the global seismic moment distribution

    NASA Astrophysics Data System (ADS)

    Serra, Isabel; Corral, Álvaro

    2017-01-01

    The distribution of seismic moment is of capital interest to evaluate earthquake hazard, in particular regarding the most extreme events. We make use of likelihood-ratio tests to compare the simple Gutenberg-Richter power-law (PL) distribution with two statistical models that incorporate an exponential tail, the so-called tapered Gutenberg-Richter (Tap) and the truncated gamma, when fitted to the global CMT earthquake catalog. Although the Tap distribution does not introduce any significant improvement of fit respect the PL, the truncated gamma does. Simulated samples of this distribution, with parameters β = 0.68 and mc = 9.15 and reshuffled in order to mimic the time occurrence of the order statistics of the empirical data, are able to explain the temporal heterogeneity of global seismicity both before and after the great Sumatra-Andaman earthquake of 2004.

  9. Power management and distribution considerations for a lunar base

    NASA Technical Reports Server (NTRS)

    Kenny, Barbara H.; Coleman, Anthony S.

    1991-01-01

    Design philosophies and technology needs for the power management and distribution (PMAD) portion of a lunar base power system are discussed. A process is described whereby mission planners may proceed from a knowledge of the PMAD functions and mission performance requirements to a definition of design options and technology needs. Current research efforts at the NASA LRC to meet the PMAD system needs for a Lunar base are described. Based on the requirements, the lunar base PMAD is seen as best being accomplished by a utility like system, although with some additional demands including autonomous operation and scheduling and accurate, predictive modeling during the design process.

  10. Distributed Optimal Power Flow of AC/DC Interconnected Power Grid Using Synchronous ADMM

    NASA Astrophysics Data System (ADS)

    Liang, Zijun; Lin, Shunjiang; Liu, Mingbo

    2017-05-01

    Distributed optimal power flow (OPF) is of great importance and challenge to AC/DC interconnected power grid with different dispatching centres, considering the security and privacy of information transmission. In this paper, a fully distributed algorithm for OPF problem of AC/DC interconnected power grid called synchronous ADMM is proposed, and it requires no form of central controller. The algorithm is based on the fundamental alternating direction multiplier method (ADMM), by using the average value of boundary variables of adjacent regions obtained from current iteration as the reference values of both regions for next iteration, which realizes the parallel computation among different regions. The algorithm is tested with the IEEE 11-bus AC/DC interconnected power grid, and by comparing the results with centralized algorithm, we find it nearly no differences, and its correctness and effectiveness can be validated.

  11. Experimental load capacity and power loss of herringbone grooved gas lubricated journal bearings.

    NASA Technical Reports Server (NTRS)

    Cunningham, R. E.; Fleming, D. P.; Anderson, W. J.

    1971-01-01

    Load capacity, attitude angle, and power loss were determined for 1-1/2-in.-diam herringbone grooved journal bearings operating in air to speeds of 60,000 rpm. Results showed that groove-to-ridge-clearance ratios of 2.0 to 2.4 give a greater load capacity than do ratios outside this optimum range. Agreement with a small-eccentricity pressure perturbation theory was good for groove-to-ridge-clearance ratios in the optimum range. Power loss, relative to that calculated for a plain bearing of the same dimensions, did not vary widely for the range of geometric variables used. Relative power loss generally increased with speed and was generally comparable to that for a plain bearing.

  12. Power distribution for an Am/Cm bushing melter

    SciTech Connect

    Gong, C.; Hardy, B.J.

    1996-12-31

    Decades of nuclear material production at the Savannah River Site (SRS) has resulted in the generation of large quantities of the isotopes Am{sup 243} and Cm{sup 244}. Currently, the Am and Cm isotopes are stored as a nitric acid solution in a tank. The Am and Cm isotopes have great commercial value but must be transferred to ORNL for processing. The nitric acid solution contains other isotopes and is intensely radioactive, which makes storage a problem and precludes shipment in the liquid form. In order to stabilize the material for onsite storage and to permit transport the material from SRS to ORNL, it has been proposed that the Am and Cm be separated from other isotopes in the solution and vitrified. Vitrification will be effected by depositing a liquid feed stream containing the isotopes in solution, together with a stream of glass frit, onto the top of a molten glass pool in a melter. The glass is non-conducting and the melter is a Platinum/Rhodium alloy vessel which is heated by passing an electric current through it. Because most of the power is required to evaporate the liquid feed at the top of the glass pool, power demands differ for the upper and lower parts of the melter. In addition, the melter is batch fed so that the local power requirements vary with time. In order to design a unique split power supply, which ensures adequate local power delivery, an analysis of the melter power distribution was performed with the ABAQUS finite element code. ABAQUS was used to calculate the electric potential and current density distributions in the melter for a variety of current and potential boundary conditions. The results of the calculation were compared with test data and will be used to compute power densities for input to a computational fluid dynamics model for the melter.

  13. Power system distributed oscilation detection based on Synchrophasor data

    NASA Astrophysics Data System (ADS)

    Ning, Jiawei

    Along with increasing demand for electricity, integration of renewable energy and deregulation of power market, power industry is facing unprecedented challenges nowadays. Within the last couple of decades, several serious blackouts have been taking place in United States. As an effective approach to prevent that, power system small signal stability monitoring has been drawing more interests and attentions from researchers. With wide-spread implementation of Synchrophasors around the world in the last decade, power systems real-time online monitoring becomes much more feasible. Comparing with planning study analysis, real-time online monitoring would benefit control room operators immediately and directly. Among all online monitoring methods, Oscillation Modal Analysis (OMA), a modal identification method based on routine measurement data where the input is unmeasured ambient excitation, is a great tool to evaluate and monitor power system small signal stability. Indeed, high sampling Synchrophasor data around power system is fitted perfectly as inputs to OMA. Existing methods in OMA for power systems are all based on centralized algorithms applying at control centers only; however, with rapid growing number of online Synchrophasors the computation burden at control centers is and will be continually exponentially expanded. The increasing computation time at control center compromises the real-time feature of online monitoring. The communication efforts between substation and control center will also be out of reach. Meanwhile, it is difficult or even impossible for centralized algorithms to detect some poorly damped local modes. In order to avert previous shortcomings of centralized OMA methods and embrace the new changes in the power systems, two new distributed oscillation detection methods with two new decentralized structures are presented in this dissertation. Since the new schemes brought substations into the big oscillation detection picture, the proposed

  14. Markers of inflammation and fat distribution following weight loss in African-American and white women.

    PubMed

    Fisher, Gordon; Hyatt, Tanya C; Hunter, Gary R; Oster, Robert A; Desmond, Renee A; Gower, Barbara A

    2012-04-01

    Changes in markers of inflammation (MOI) and fat distribution with weight loss between African-American (AA) and white (W) women have yet to be characterized. The purpose of this study was to examine potential ethnic differences in MOI and regional fat distribution with weight loss, and identify the associations between these markers and changes in regional fat distribution with weight loss among AA and W women. Subjects were 126 healthy, premenopausal women, BMI 27-30 kg/m(2). They were placed on a weight-loss intervention consisting of diet and/or exercise until a BMI <25 was achieved. Fat distribution was measured with computed tomography, and body composition with dual-energy X-ray absorptiometry. Serum concentrations of tumor necrosis factor-α (TNF-α), soluble TNF receptor-I (sTNFR-I), sTNFR-II, C-reactive protein (CRP), and interleukin-6 (IL-6) were assessed. All MOI and adiposity measures significantly decreased with weight loss. Significant ethnic differences with weight loss were observed for fat mass, body fat, intra-abdominal adipose tissue (IAAT), sTNFR-I, and sTNFR-II. Mixed-model analysis indicated that adjusting for change in IAAT explained ethnic differences in change in TNF-α and the decrease in TNF-α with weight loss, while total fat mass only explained the decrease in sTNFR-I and sTNFR-II with weight loss. In conclusion, all MOI decreased following weight loss among W, whereas only IL-6 and CRP decreased following weight loss in AA. The most distinct phenotypic difference observed was a greater impact of weight loss on TNF-α in W compared to AA, which was directly associated with IAAT in W.

  15. Markers of Inflammation and Fat Distribution following Weight Loss in African American and Caucasian Women

    PubMed Central

    Fisher, Gordon; Hyatt, Tanya C.; Hunter, Gary R.; Oster, Robert A.; Desmond, Renee A.; Gower, Barbara A.

    2013-01-01

    Changes in markers of inflammation (MOI) and fat distribution with weight loss between African American (AA) and Caucasian (C) women have yet to be characterized. The purpose of this study was to examine potential ethnic differences in MOI and regional fat distribution with weight loss, and identify the associations between these markers and changes in regional fat distribution with weight loss among AA and C women. Subjects were 126 healthy, premenopausal women, BMI 27–30 kg/m2. They were placed on a weight loss intervention consisting of diet and/or exercise until a BMI < 25 was achieved. Fat distribution was measured with computed tomography, and body composition with dual-energy X-ray absorptiometry. Serum concentrations of tumor necrosis factor (TNF)-α, soluble tumor necrosis factor receptor (sTNFR)-I, sTNFR-II, C-reactive protein (CRP), and interleukin (IL)-6 were assessed. All MOI and adiposity measures significantly decreased with weight loss. Significant ethnic differences with weight loss were observed for fat mass, body fat, intra-abdominal adipose tissue (IAAT), sTNF-RI, and sTNF-RII. Mixed-model analysis indicated that adjusting for change in IAAT explained ethnic differences in change in TNF-α and the decrease in TNF-α with weight loss, while total fat mass only explained the decrease in sTNF-RI and sTNF-RII with weight loss. In conclusion, all MOI decreased following weight loss among C, whereas only IL-6 and CRP decreased following weight loss in AA. The most distinct phenotypic difference observed was a greater impact of weight loss on TNF-α in C compared to AA, which was directly associated with IAAT in C. PMID:21527894

  16. Distributed Optimal Generation Control of Shipboard Power Systems

    DTIC Science & Technology

    2012-05-01

    address the needs of SPSs, a fully-distributed, multi - agent system (MAS)-based solution is proposed to optimize the control references of distributed...Transactions on Power Systems, Vol.27, No.1, pp.233-242, Feb. 2012. [4] J. M. Solanki and N. N. Schulz, “Using intelligent multi - agent systems for shipboard...D 2005/2006, pp. 562-567, May 21-24, 2006. [11] J. A. Momoh, K. Alfred and Y. Xia, “Framework for Multi - Agent System (MAS) Detection and Control

  17. Distributed Optimal Generation Control of Shipboard Power Systems

    DTIC Science & Technology

    2012-05-01

    address the needs of SPSs, a fully-distributed, multi - agent system (MAS)-based solution is proposed to optimize the control references of distributed...Systems, Vol.27, No.1, pp.233-242, Feb. 2012. [4] J. M. Solanki and N. N. Schulz, “Using intelligent multi - agent systems for shipboard power...pp. 562-567, May 21-24, 2006. [11] J. A. Momoh, K. Alfred and Y. Xia, “Framework for Multi - Agent System (MAS) Detection and Control of Arcing of

  18. Electric power scheduling: A distributed problem-solving approach

    NASA Technical Reports Server (NTRS)

    Mellor, Pamela A.; Dolce, James L.; Krupp, Joseph C.

    1990-01-01

    Space Station Freedom's power system, along with the spacecraft's other subsystems, needs to carefully conserve its resources and yet strive to maximize overall Station productivity. Due to Freedom's distributed design, each subsystem must work cooperatively within the Station community. There is a need for a scheduling tool which will preserve this distributed structure, allow each subsystem the latitude to satisfy its own constraints, and preserve individual value systems while maintaining Station-wide integrity. The value-driven free-market economic model is such a tool.

  19. HIGH-POWER RF DISTRIBUTION SYSTEMFOR THE 8-PACK PROJECT

    SciTech Connect

    Nantista, C

    2004-08-24

    The 8-Pack Project at SLAC is a prototype rf system whose goal is to demonstrate the high-power X-band technology developed in the NLC/GLC (Next/Global Linear Collider) program. In its first phase, it has reliably produced a 400 ns rf pulse of over 500 MW using a solidstate modulator, four 11.424 GHz klystrons and a dualmoded SLED-II pulse compressor. In Phase 2, the output power of the system has been delivered into the bunker of the NLCTA (Next Linear Collider Test Accelerator) and divided between several accelerator structures for beam acceleration. The authors describe here the design, cold-test measurements, and processing of this power distribution system. Due to the high power levels and the need for efficiency, overmoded waveguide and components are used. For power transport, the TE{sub 01} mode is used in 7.44 cm and 4.064 cm diameter circular waveguide. Only near the structures is standard WR90 rectangular waveguide employed. Components used to manipulate the rf power include transitional tapers, mode converters, overmoded bends, fractional directional couplers, and hybrids.

  20. Wireless Power Transfer for Distributed Estimation in Sensor Networks

    NASA Astrophysics Data System (ADS)

    Mai, Vien V.; Shin, Won-Yong; Ishibashi, Koji

    2017-04-01

    This paper studies power allocation for distributed estimation of an unknown scalar random source in sensor networks with a multiple-antenna fusion center (FC), where wireless sensors are equipped with radio-frequency based energy harvesting technology. The sensors' observation is locally processed by using an uncoded amplify-and-forward scheme. The processed signals are then sent to the FC, and are coherently combined at the FC, at which the best linear unbiased estimator (BLUE) is adopted for reliable estimation. We aim to solve the following two power allocation problems: 1) minimizing distortion under various power constraints; and 2) minimizing total transmit power under distortion constraints, where the distortion is measured in terms of mean-squared error of the BLUE. Two iterative algorithms are developed to solve the non-convex problems, which converge at least to a local optimum. In particular, the above algorithms are designed to jointly optimize the amplification coefficients, energy beamforming, and receive filtering. For each problem, a suboptimal design, a single-antenna FC scenario, and a common harvester deployment for colocated sensors, are also studied. Using the powerful semidefinite relaxation framework, our result is shown to be valid for any number of sensors, each with different noise power, and for an arbitrarily number of antennas at the FC.

  1. High-frequency ac power distribution in Space Station

    NASA Technical Reports Server (NTRS)

    Tsai, Fu-Sheng; Lee, Fred C. Y.

    1990-01-01

    A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

  2. Optimal Power Flow for Distribution Systems under Uncertain Forecasts: Preprint

    SciTech Connect

    Dall'Anese, Emiliano; Baker, Kyri; Summers, Tyler

    2016-12-01

    The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

  3. Optimal Power Flow for Distribution Systems under Uncertain Forecasts

    SciTech Connect

    Dall'Anese, Emiliano; Baker, Kyri; Summers, Tyler

    2016-12-29

    The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

  4. Power-law distribution in Japanese racetrack betting

    NASA Astrophysics Data System (ADS)

    Ichinomiya, Takashi

    2006-08-01

    Gambling is one of the basic economic activities that humans indulge in. An investigation of gambling activities provides deep insights into the economic actions of people and sheds lights on the study of econophysics. In this paper we present an analysis of the distribution of the final odds of the races organized by the Japan Racing Association. The distribution of the final odds Po(x) indicates a clear power-law Po(x)∝1/x, where x represents the final odds. This power-law can be explained on the basis of the assumption that every bettor bets his money on the horse that appears to be the strongest in a race.

  5. Eddy current power loss in structural steel due to cables carrying current in a perpendicular direction

    SciTech Connect

    Namjoshi, K.V.; Lavers, J.D.; Biringer, P.P. . Dept. of Electrical and Computer Engineering)

    1994-01-01

    This paper deals with eddy current power loss in structural steel, in the vicinity of cables carrying current in a perpendicular direction. The configuration is approximated by a long cylinder perpendicular to a filament current. An analytical method is used. Expressions are provided which describe the frequency dependence of the power loss. The influence of the permeability and the physical dimensions is considered. Formulae are given for the impedance of the cylinder in different frequency regions. Numerical results are presented to show the behavior.

  6. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2004-01-01

    Advanced brush and finger seal technologies offer reduced leakage rates over conventional labyrinth seals used in gas turbine engines. To address engine manufacturers concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature Turbine Seal Test Rig. Leakage and power loss test results are compared for these competing seals for operating conditions up to 922 K (1200 F) inlet air temperature, 517 KPa (75 psid) across the seal, and surface velocities up to 366 m/s (1200 ft/s).

  7. A Numerical Study of Water Loss Rate Distributions in MDCT-based Human Airway Models

    PubMed Central

    Wu, Dan; Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Lin, Ching-Long

    2015-01-01

    Both three-dimensional (3D) and one-dimensional (1D) computational fluid dynamics (CFD) methods are applied to study regional water loss in three multi-detector row computed-tomography (MDCT)-based human airway models at the minute ventilations of 6, 15 and 30 L/min. The overall water losses predicted by both 3D and 1D models in the entire respiratory tract agree with available experimental measurements. However, 3D and 1D models reveal different regional water loss rate distributions due to the 3D secondary flows formed at bifurcations. The secondary flows cause local skewed temperature and humidity distributions on inspiration acting to elevate the local water loss rate; and the secondary flow at the carina tends to distribute more cold air to the lower lobes. As a result, the 3D model predicts that the water loss rate first increases with increasing airway generation, and then decreases as the air approaches saturation, while the 1D model predicts a monotonic decrease of water loss rate with increasing airway generation. Moreover, the 3D (or 1D) model predicts relatively higher water loss rates in lower (or upper) lobes. The regional water loss rate can be related to the non-dimensional wall shear stress (τ*) by the non-dimensional mass transfer coefficient (h0*) as h0* = 1.15 τ*0.272, R = 0.842. PMID:25869455

  8. A Numerical Study of Water Loss Rate Distributions in MDCT-Based Human Airway Models.

    PubMed

    Wu, Dan; Miyawaki, Shinjiro; Tawhai, Merryn H; Hoffman, Eric A; Lin, Ching-Long

    2015-11-01

    Both three-dimensional (3D) and one-dimensional (1D) computational fluid dynamics methods are applied to study regional water loss in three multi-detector row computed-tomography-based human airway models at the minute ventilations of 6, 15 and 30 L/min. The overall water losses predicted by both 3D and 1D models in the entire respiratory tract agree with available experimental measurements. However, 3D and 1D models reveal different regional water loss rate distributions due to the 3D secondary flows formed at bifurcations. The secondary flows cause local skewed temperature and humidity distributions on inspiration acting to elevate the local water loss rate; and the secondary flow at the carina tends to distribute more cold air to the lower lobes. As a result, the 3D model predicts that the water loss rate first increases with increasing airway generation, and then decreases as the air approaches saturation, while the 1D model predicts a monotonic decrease of water loss rate with increasing airway generation. Moreover, the 3D (or 1D) model predicts relatively higher water loss rates in lower (or upper) lobes. The regional water loss rate can be related to the non-dimensional wall shear stress (τ (*)) by the non-dimensional mass transfer coefficient (h 0 (*) ) as [Formula: see text].

  9. Distributed Solar Photovoltaic Power Production - Technology and Benefits

    SciTech Connect

    Matos, Al; Stuby, Rick

    2011-11-02

    As part of its nationally recognized Solar 4 All program, PSE&G has partnered with Petra Solar to deploy the world’s first and largest pole attached solar project. The project, based on Petra Solar’s distributed Smart Solar solution, will create a 40 megawatt solar “virtual power plant.” In deployment as 200,000 individual grid-connected solar power producers on utility poles in PSE&G territory, Petra Solar SunWave® solutions leverage Smart Grid communications and high-tech panel-level inverters to implement a robust system with many technical benefits over traditional solar photovoltaic solutions. The program overview, deployment model, smart grid communications and enabling inverter technology and safety features will be presented, as well the future challenges of, and solutions for, solar power intermittency as photovoltaic penetration on the electric grid increases.

  10. Emergency preparedness for power outages and wi-fi loss: tips for students and educators of online courses.

    PubMed

    Heithaus, Teresa

    2015-01-01

    Severe weather can impact online education due to a loss of power and Internet access that can last hours or weeks. Planning for such losses is essential to enable participation in the online classroom. This article discusses measures that can be used to maintain an online presence in the event of a power outage or loss of Wi-Fi.

  11. Design of Instantaneous High Power Supply System with power distribution management for portable military devices

    NASA Astrophysics Data System (ADS)

    Kwak, Kiho; Kwak, Dongmin; Yoon, Joohong

    2015-08-01

    A design of an Instantaneous High Power Supply System (IHPSS) with a power distribution management (PDM) for portable military devices is newly addressed. The system includes a power board and a hybrid battery that can not only supply instantaneous high power but also maintain stable operation at critical low temperature (-30 °C). The power leakage and battery overcharge are effectively prevented by the optimal PDM. The performance of the proposed system under the required pulse loads and the operating conditions of a Korean Advanced Combat Rifle employed in the battlefield is modeled with simulations and verified experimentally. The system with the IHPSS charged the fuse setter with 1.7 times higher voltage (8.6 V) than the one without (5.4 V) under the pulse discharging rate (1 A at 0.5 duty, 1 ms) for 500 ms.

  12. 26 CFR 1.735-1 - Character of gain or loss on disposition of distributed property.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... distributed property—(1) Unrealized receivables. Any gain realized or loss sustained by a partner on a sale or... by a partner on a sale or exchange of inventory items (as defined in section 751(d)(2)) received in a... partner of such inventory items after 5 years from the date of distribution shall be determined as of...

  13. Assessment of distributed solar power systems: Issues and impacts

    NASA Astrophysics Data System (ADS)

    Moyle, R. A.; Chernoff, H.; Schweizer, T. C.; Patton, J. B.

    1982-11-01

    The installation of distributed solar-power systems presents electric utilities with a host of questions. Some of the technical and economic impacts of these systems are discussed. Among the technical interconnect issues are isolated operation, power quality, line safety, and metering options. Economic issues include user purchase criteria, structures and installation costs, marketing and product distribution costs, and interconnect costs. An interactive computer program that allows easy calculation of allowable system prices and allowable generation-equipment prices was developed as part of this project. It is concluded that the technical problems raised by distributed solar systems are surmountable, but their resolution may be costly. The stringent purchase criteria likely to be imposed by many potential system users and the economies of large-scale systems make small systems (less than 10 to 20 kW) less attractive than larger systems. Utilities that consider life-cycle costs in making investment decisions and third-party investors who have tax and financial advantages are likely to place the highest value on solar-power systems.

  14. Power Management and Distribution (PMAD) Model Development: Final Report

    NASA Technical Reports Server (NTRS)

    Metcalf, Kenneth J.

    2011-01-01

    Power management and distribution (PMAD) models were developed in the early 1990's to model candidate architectures for various Space Exploration Initiative (SEI) missions. They were used to generate "ballpark" component mass estimates to support conceptual PMAD system design studies. The initial set of models was provided to NASA Lewis Research Center (since renamed Glenn Research Center) in 1992. They were developed to estimate the characteristics of power conditioning components predicted to be available in the 2005 timeframe. Early 90's component and device designs and material technologies were projected forward to the 2005 timeframe, and algorithms reflecting those design and material improvements were incorporated into the models to generate mass, volume, and efficiency estimates for circa 2005 components. The models are about ten years old now and NASA GRC requested a review of them to determine if they should be updated to bring them into agreement with current performance projections or to incorporate unforeseen design or technology advances. This report documents the results of this review and the updated power conditioning models and new transmission line models generated to estimate post 2005 PMAD system masses and sizes. This effort continues the expansion and enhancement of a library of PMAD models developed to allow system designers to assess future power system architectures and distribution techniques quickly and consistently.

  15. Experimental study of flow distribution and pressure loss with circumferential inlet and outlet manifolds

    NASA Technical Reports Server (NTRS)

    Dittrich, R. T.

    1972-01-01

    Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.

  16. Energy loss distributions of 7 TeV protons axially channeled in the bent <1 1 0> Si crystal

    NASA Astrophysics Data System (ADS)

    Stojanov, Nace; Petrović, Srdjan

    2016-04-01

    In this article, the energy loss distributions of relativistic protons axially channeled in the bent <1 1 0> Si crystal are studied. The crystal thickness is equal to 1 mm, which corresponds to the reduced crystal thickness, Λ, equal to 1.22, whereas the bending angle, α, was varied from 0 to 30 μrad. The proton energy of 7 TeV was chosen in accordance with the concept of using the bent crystals as a tool for selective deflection of the beam halo particles from the LUA9 experiment at LHC. For the continuum interaction potential of the proton and the crystal the Molière's expression was used and the energy loss of a proton was calculated by applying the trajectory dependent stopping power model. Further, the uncertainness of the scattering angle of the proton caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The energy loss distribution of the channeled protons was obtained via the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. The analysis of the obtained theoretical data shows that the shape of the energy loss distribution strongly depends on the horizontal or vertical direction of the curvature of the crystal. The number of dechanneled protons as a function of the bending angle also strongly depends on the direction of the crystal's curvature. As a result, the dechanneling rates and ranges, obtained from the Gompertz type sigmoidal fitting functions, have different sets of values for different bending orientations. We have also studied the influence of the proton beam divergence on the energy loss distribution of channeled protons.

  17. High-power and narrow-linewidth tunable distributed-reflector laser

    NASA Astrophysics Data System (ADS)

    Kaneko, Toshimitsu; Matsuura, Hiroyuki; Tanizawa, Ken; Uesaka, Katsumi

    2016-02-01

    Deployment of digital coherent transmission technologies to metro networks drives the use of higher-order modulation formats such as PDM-16QAM and downsizing of optical transceivers. A narrow-linewidth (<300 kHz) tunable laser with high output power (>+17 dBm) is very attractive for such purposes, not only because it can compensate for the modulation loss increase caused by a high-peak-to-average ratio of the electrical driving signal of higher-order modulation formats, but also because it can be shared between transmitter and receiver saving the foot-print and power dissipation. This paper reviews the Tunable Distributed Amplification -- Chirped Sampled Grating -- Distributed Reflector (TDA-CSG-DR) laser being developed for metro application.

  18. Decisions with Uncertain Consequences—A Total Ordering on Loss-Distributions

    PubMed Central

    König, Sandra; Schauer, Stefan

    2016-01-01

    Decisions are often based on imprecise, uncertain or vague information. Likewise, the consequences of an action are often equally unpredictable, thus putting the decision maker into a twofold jeopardy. Assuming that the effects of an action can be modeled by a random variable, then the decision problem boils down to comparing different effects (random variables) by comparing their distribution functions. Although the full space of probability distributions cannot be ordered, a properly restricted subset of distributions can be totally ordered in a practically meaningful way. We call these loss-distributions, since they provide a substitute for the concept of loss-functions in decision theory. This article introduces the theory behind the necessary restrictions and the hereby constructible total ordering on random loss variables, which enables decisions under uncertainty of consequences. Using data obtained from simulations, we demonstrate the practical applicability of our approach. PMID:28030572

  19. A Stable 0.2-THz Coaxial-Waveguide Gyrotron Traveling-Wave-Tube Amplifier with Distributed Losses

    NASA Astrophysics Data System (ADS)

    Hung, C. L.; Yeh, Y. S.; Chang, T. H.; Fang, R. S.

    2017-01-01

    For high-power operation, a THz gyrotron traveling-wave-tube (gyro-TWT) amplifier must operate in a high-order waveguide mode to enlarge the transverse dimension of an interaction waveguide. However, a gyro-TWT amplifier operating in a high-order waveguide mode is susceptible to spurious oscillations. To improve the device stability, in this study, we investigate the possibility of using a coaxial waveguide with distributed losses as the interaction structure. For the same required attenuation, all threatening oscillating modes can be suppressed using different combinations of losses of inner and outer cylinders. This provides flexibility in designing distributed losses when considering the ohmic loading of the interaction structure. We predict that the 0.2-THz gyro-TWT can stably produce a peak power of 14 kW with an efficiency of 23 %, a 3-dB bandwidth of 3.5 GHz, and a saturated gain of 50 dB for a 20-kV 3-A electron beam with a 5 % velocity spread and 1.0 velocity ratio.

  20. Using Reanalysis Data for the Prediction of Seasonal Wind Turbine Power Losses Due to Icing

    NASA Astrophysics Data System (ADS)

    Burtch, D.; Mullendore, G. L.; Delene, D. J.; Storm, B.

    2013-12-01

    The Northern Plains region of the United States is home to a significant amount of potential wind energy. However, in winter months capturing this potential power is severely impacted by the meteorological conditions, in the form of icing. Predicting the expected loss in power production due to icing is a valuable parameter that can be used in wind turbine operations, determination of wind turbine site locations and long-term energy estimates which are used for financing purposes. Currently, losses due to icing must be estimated when developing predictions for turbine feasibility and financing studies, while icing maps, a tool commonly used in Europe, are lacking in the United States. This study uses the Modern-Era Retrospective Analysis for Research and Applications (MERRA) dataset in conjunction with turbine production data to investigate various methods of predicting seasonal losses (October-March) due to icing at two wind turbine sites located 121 km apart in North Dakota. The prediction of icing losses is based on temperature and relative humidity thresholds and is accomplished using three methods. For each of the three methods, the required atmospheric variables are determined in one of two ways: using industry-specific software to correlate anemometer data in conjunction with the MERRA dataset and using only the MERRA dataset for all variables. For each season, a percentage of the total expected generated power lost due to icing is determined and compared to observed losses from the production data. An optimization is performed in order to determine the relative humidity threshold that minimizes the difference between the predicted and observed values. Eight seasons of data are used to determine an optimal relative humidity threshold, and a further three seasons of data are used to test this threshold. Preliminary results have shown that the optimized relative humidity threshold for the northern turbine is higher than the southern turbine for all methods

  1. Enhanced power quality based single phase photovoltaic distributed generation system

    NASA Astrophysics Data System (ADS)

    Panda, Aurobinda; Pathak, M. K.; Srivastava, S. P.

    2016-08-01

    This article presents a novel control strategy for a 1-ϕ 2-level grid-tie photovoltaic (PV) inverter to enhance the power quality (PQ) of a PV distributed generation (PVDG) system. The objective is to obtain the maximum benefits from the grid-tie PV inverter by introducing current harmonics as well as reactive power compensation schemes in its control strategy, thereby controlling the PV inverter to achieve multiple functions in the PVDG system such as: (1) active power flow control between the PV inverter and the grid, (2) reactive power compensation, and (3) grid current harmonics compensation. A PQ enhancement controller (PQEC) has been designed to achieve the aforementioned objectives. The issue of underutilisation of the PV inverter in nighttime has also been addressed in this article and for the optimal use of the system; the PV inverter is used as a shunt active power filter in nighttime. A prototype model of the proposed system is developed in the laboratory, to validate the effectiveness of the control scheme, and is tested with the help of the dSPACE DS1104 platform.

  2. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    David Deangelis; Rich Depuy; Debashis Dey; Georgia Karvountzi; Nguyen Minh; Max Peter; Faress Rahman; Pavel Sokolov; Deliang Yang

    2004-09-30

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the April to October 2004 reporting period in Task 2.3 (SOFC Scaleup for Hybrid and Fuel Cell Systems) under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL), entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. This study analyzes the performance and economics of power generation systems for central power generation application based on Solid Oxide Fuel Cell (SOFC) technology and fueled by natural gas. The main objective of this task is to develop credible scale up strategies for large solid oxide fuel cell-gas turbine systems. System concepts that integrate a SOFC with a gas turbine were developed and analyzed for plant sizes in excess of 20 MW. A 25 MW plant configuration was selected with projected system efficiency of over 65% and a factory cost of under $400/kW. The plant design is modular and can be scaled to both higher and lower plant power ratings. Technology gaps and required engineering development efforts were identified and evaluated.

  3. Active and Reactive Power Optimal Dispatch Associated with Load and DG Uncertainties in Active Distribution Network

    NASA Astrophysics Data System (ADS)

    Gao, F.; Song, X. H.; Zhang, Y.; Li, J. F.; Zhao, S. S.; Ma, W. Q.; Jia, Z. Y.

    2017-05-01

    In order to reduce the adverse effects of uncertainty on optimal dispatch in active distribution network, an optimal dispatch model based on chance-constrained programming is proposed in this paper. In this model, the active and reactive power of DG can be dispatched at the aim of reducing the operating cost. The effect of operation strategy on the cost can be reflected in the objective which contains the cost of network loss, DG curtailment, DG reactive power ancillary service, and power quality compensation. At the same time, the probabilistic constraints can reflect the operation risk degree. Then the optimal dispatch model is simplified as a series of single stage model which can avoid large variable dimension and improve the convergence speed. And the single stage model is solved using a combination of particle swarm optimization (PSO) and point estimate method (PEM). Finally, the proposed optimal dispatch model and method is verified by the IEEE33 test system.

  4. Emissivity-corrected power loss calibration for lock-in thermography measurements on silicon solar cells

    SciTech Connect

    Kasemann, Martin; Walter, Benjamin; Meinhardt, Christoph; Ebser, Jan; Kwapil, Wolfram; Warta, Wilhelm

    2008-06-01

    This paper describes power loss calibration procedures with implemented emissivity correction. The determination of our emissivity correction matrix does neither rely on blackbody reference measurements nor on the knowledge of any sample temperatures. To describe the emissivity-corrected power calibration procedures in detail, we review the theory behind lock-in thermography and show experimentally that the lock-in signal is proportional to the power dissipation in the solar cell. Experiments show the successful application of our emissivity correction procedure, which significantly improves the informative value of lock-in thermography images and the reliability of the conclusions drawn from these images.

  5. Optical frequency modulated pulse power losses, caused by optical fiber material dispersion

    NASA Astrophysics Data System (ADS)

    Ivanov, Dmitry V.; Ivanov, Vladimir A.; Ryabova, Natalia V.; Ryabova, Maria I.; Chernov, Andrei A.; Konkin, Nikita A.

    2017-04-01

    The equations were obtained to estimate the pulse power losses of broadband light pulses caused by material dispersion in an optical fiber. It was found that the dispersion caused by the extension of a signal bandwidth leads to decreasing a signal base as well as the noise immunity of a system, which uses broadband pulses.

  6. Influence of Design Parameters on Mechanical Power Losses of Helical Gear Pairs

    NASA Astrophysics Data System (ADS)

    Li, Sheng; Vaidyanathan, Aarthy; Harianto, Jonny; Kahraman, Ahmet

    In this study, the influence of basic design parameters and tooth surface modifications on the mechanical (friction induced) power losses of a helical gear pair is studied. A helical gear mechanical efficiency model based on elastohydrodynamic lubrication (EHL) is introduced. The model is used to simulate the gear contact conditions of an example helical gear pair within the ranges of basic design parameter such as pressure and helix angles, number of teeth (module), and major diameters to quantify their impact on mechanical power losses. Variation of gear efficiency with these parameters are then weighed against other functional requirements such as transmission error amplitudes, and contact and bending stresses to demonstrate that many designs that have high efficiency might perform poorly in terms of noise, pitting, and tooth breakage. A representative design that is acceptable in all aspects is considered next with varying amounts of tooth modifications to demonstrate their impact on power losses. At the end, recommendations are made on how to reduce helical gear mechanical power losses while meeting other functional requirements as well.

  7. Construction and Application of Theoretical Line Loss Calculation Platform for 220 kV and above Power Grid in Shanghai

    NASA Astrophysics Data System (ADS)

    Yang, F.; Liu, J.; Li, S. Q.

    2017-05-01

    Instead of drawing power grid and inputting component parameters manually to establish calculation model, the theoretical line loss calculation platform for 220 kV and above power grid in Shanghai is developed based on grid dispatching D5000 system, capable of capturing real-time power grid basic / operational data and offline graphics saving. It resolves all data for previous day automatically before commencing theoretical line loss calculation. The theoretical line loss calculation results for 500 / 220 kV showed its validity and accuracy. The project effectively accumulates the scientific data and promote State Grid Shanghai Municipal Electric Power Company to fully grasp the related equipment operating conditions of Shanghai 500 / 220kV power grid. The analysis results not only help power company to guide production practice, but also provide a better understanding for power grid weakness and loss composition, which enables power company managers to guide future construction and transformation of power grid accurately and effectively.

  8. Study on AC loss measurements of HTS power cable for standardizing

    NASA Astrophysics Data System (ADS)

    Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi

    2017-09-01

    High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..

  9. Design of Distributed Controllers Seeking Optimal Power Flow Solutions under Communication Constraints: Preprint

    SciTech Connect

    Dall'Anese, Emiliano; Simonetto, Andrea; Dhople, Sairaj

    2016-12-01

    This paper focuses on power distribution networks featuring inverter-interfaced distributed energy resources (DERs), and develops feedback controllers that drive the DER output powers to solutions of time-varying AC optimal power flow (OPF) problems. Control synthesis is grounded on primal-dual-type methods for regularized Lagrangian functions, as well as linear approximations of the AC power-flow equations. Convergence and OPF-solution-tracking capabilities are established while acknowledging: i) communication-packet losses, and ii) partial updates of control signals. The latter case is particularly relevant since it enables asynchronous operation of the controllers where DER setpoints are updated at a fast time scale based on local voltage measurements, and information on the network state is utilized if and when available, based on communication constraints. As an application, the paper considers distribution systems with high photovoltaic integration, and demonstrates that the proposed framework provides fast voltage-regulation capabilities, while enabling the near real-time pursuit of solutions of AC OPF problems.

  10. Design of Distributed Controllers Seeking Optimal Power Flow Solutions Under Communication Constraints

    SciTech Connect

    Dall'Anese, Emiliano; Simonetto, Andrea; Dhople, Sairaj

    2016-12-29

    This paper focuses on power distribution networks featuring inverter-interfaced distributed energy resources (DERs), and develops feedback controllers that drive the DER output powers to solutions of time-varying AC optimal power flow (OPF) problems. Control synthesis is grounded on primal-dual-type methods for regularized Lagrangian functions, as well as linear approximations of the AC power-flow equations. Convergence and OPF-solution-tracking capabilities are established while acknowledging: i) communication-packet losses, and ii) partial updates of control signals. The latter case is particularly relevant since it enables asynchronous operation of the controllers where DER setpoints are updated at a fast time scale based on local voltage measurements, and information on the network state is utilized if and when available, based on communication constraints. As an application, the paper considers distribution systems with high photovoltaic integration, and demonstrates that the proposed framework provides fast voltage-regulation capabilities, while enabling the near real-time pursuit of solutions of AC OPF problems.

  11. About Losses in Pumping Generators of High-Power Electrodischarge Excimer Lasers

    NASA Astrophysics Data System (ADS)

    Ivanov, N. G.; Losev, V. F.

    2015-04-01

    Energy losses in pumping systems of discharge high-power lasers are investigated. To estimate the losses, the discharge circuit operation was modeled, and its calculation was performed using the program PSpice. Results of measurements and calculations demonstrate that the resistance of a rail gap with electric field distortion exceeds several times the resistance of a single-channel gap without field distortion. A difference in the resistances is explained by different mechanisms of discharge burning: in the first case diffusion mechanism and in the second case the spark mechanism. The low efficiency of the high-power excimer lasers (~1%) is explained by high energy losses in the rail gap that reach more than 50% of the initially stored energy.

  12. Analysis on heat loss characteristics of a 10 kV HTS power substation

    NASA Astrophysics Data System (ADS)

    Teng, Yuping; Dai, Shaotao; Song, Naihao; Zhang, Jingye; Gao, Zhiyuan; Zhu, Zhiqin; Zhou, Weiwei; Wei, Zhourong; Lin, Liangzhen; Xiao, Liye

    2014-09-01

    A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

  13. Effect of Distributed Photovoltaic Generation on the Voltage Magnitude in a Self-Contained Power Supply System

    NASA Astrophysics Data System (ADS)

    Lukutin, B. V.; Shandarova, E. B.; Makarova, A. F.; Shvartsman, I. B.

    2016-04-01

    A promising way to increase the technical and economic characteristics of standalone power supply systems is to incorporate renewable energy installations in their structure. This saves fuel and extends the operational life of diesel power stations. The most common option is a hybrid system with photovoltaic power stations incorporated into the local network of the diesel power station. This paper deals with the dependence of the deflection voltage and power losses in the electric power transmission line on the graphs of electrical loads, the parameters of elements of the power supply system, connection points and the capacity of distributed photovoltaic power stations. Research has been carried out on the common low-voltage power supply systems of the radial type (0.4 kV) with an installed capacity of up to 100 kW. The studies have been conducted by simulating the operating modes of hybrid power systems of various configurations. As a result of these studies recommendations to reduce losses and voltage variations in the network by selecting the power and photovoltaic power connection points have been put forward.

  14. Modeling turbine wakes and power losses within the Horns Rev offshore wind farm using large-eddy simulation

    NASA Astrophysics Data System (ADS)

    Wu, Yu-Ting; Porte-Agel, Fernando

    2013-04-01

    A recently-developed large-eddy simulations (LES) framework is implemented to predict multiple wake flows and the associated power losses within the Horns Rev offshore wind farm under near-neutral stability conditions. A tuning-free Lagrangian scale-dependent dynamic subgrid-scale (SGS) model is used for the parametrization of the SGS stresses. The turbine-generated power outputs and the turbine-induced forces (e.g., thrust, lift, drag) are parameterized using two models: (a) the traditional actuator-disk model without rotation (ADM-NR), which uses the 1D momentum theory to relate the power output and the thrust force with a representative velocity over the rotor (e.g., the disk-averaged velocity); and (b) the actuator-disk model with rotation (ADM-R), which adopts blade element theory to calculate the lift and drag forces (that produce thrust, rotor shaft torque, and power) based on the local blade and flow characteristics. In general, the predicted power outputs obtained using the ADM-R are in good agreement with observed power data from the Horns Rev wind farm. The ADM-NR tends to underestimate the power output. A similar under-prediction is obtained using industry-standard wind-farm models such as the Wind Atlas Analysis and Application Program (WAsP). Simulations using different inflow conditions show that the mean wind direction has a strong effect on the spatial distributions of the time-averaged velocity and the turbulence intensity within the farm. These, in turn, affect the power output and the fatigue loads on the turbines. When the prevailing wind direction is parallel to the turbine rows (i.e., a full wake condition), the velocity deficit and the power losses are largest, and the turbulence intensity levels are highest and have a symmetric pattern (dual-peak at hub height) on both sides of the turbine wakes. A detailed analysis of the turbulence kinetic energy budget in the full wake condition shows an important effect of the increased turbulence level

  15. Multi-Code Ab Initio Calculation of Ionization Distributions and Radiation Losses for Tungsten in Tokamak Plasmas

    SciTech Connect

    Ralchenko, Yu.; Abdallah, J. Jr.; Colgan, J.; Fontes, C. J.; Foster, M.; Zhang, H. L.; Bar-Shalom, A.; Oreg, J.; Bauche, J.; Bauche-Arnoult, C.; Bowen, C.; Faussurier, G.; Chung, H.-K.; Hansen, S. B.; Lee, R. W.; Scott, H.; Gaufridy de Dortan, F. de; Poirier, M.; Golovkin, I.; Novikov, V.

    2009-09-10

    We present calculations of ionization balance and radiative power losses for tungsten in magnetic fusion plasmas. The simulations were performed within the framework of Non-Local Thermodynamic Equilibrium (NLTE) Code Comparison Workshops utilizing several independent collisional-radiative models. The calculations generally agree with each other; however, a clear disagreement with experimental ionization distributions at low temperatures 2 keV

  16. Economic optimization of the energy transport component of a large distributed solar power plant

    NASA Technical Reports Server (NTRS)

    Turner, R. H.

    1976-01-01

    A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.

  17. Economic optimization of the energy transport component of a large distributed solar power plant

    NASA Technical Reports Server (NTRS)

    Turner, R. H.

    1976-01-01

    A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.

  18. Intraluminal ultrasound intensity distribution and backscattered Doppler power.

    PubMed

    Thompson, Rosemary S; Bambi, Giacomo; Steel, Robin; Tortoli, Piero

    2004-11-01

    Ultrasound (US) incident obliquely on a cylindrical vessel is redistributed in space when the propagation path includes walls with acoustic impedance different from that of the surrounding media. We investigated this using low-density polyethylene (PE) as the vessel wall material. Both simulations and experiments were carried out. Direct hydrophone measurements of the acoustic field were made within a half section of the PE tube, and the distribution of backscattered Doppler power along a scan line was obtained using a range-Doppler instrument. Both simulation and hydrophone results demonstrate lateral shadow regions within the lumen. In every one of various Doppler flow experiments conducted, the backscattered Doppler power, compensated for on-axis transducer behaviour, increased with depth. Simulation results for an incident continuous-wave (CW) plane wave show that it tends to be focused by the curvature of the PE tube walls. The wall interactions are, however, angle-dependent and so the behaviour of a focused US beam depends on the beam as well as the walls. This study demonstrates alterations in the spatial distribution of US within a cylindrical vessel as a result of known vessel wall properties. It also provides evidence that local intensity variations within the lumen affect the relative Doppler power backscattered from small sample volumes.

  19. Life cycle assessment of overhead and underground primary power distribution.

    PubMed

    Bumby, Sarah; Druzhinina, Ekaterina; Feraldi, Rebe; Werthmann, Danae; Geyer, Roland; Sahl, Jack

    2010-07-15

    Electrical power can be distributed in overhead or underground systems, both of which generate a variety of environmental impacts at all stages of their life cycles. While there is considerable literature discussing the trade-offs between both systems in terms of aesthetics, safety, cost, and reliability, environmental assessments are relatively rare and limited to power cable production and end-of-life management. This paper assesses environmental impacts from overhead and underground medium voltage power distribution systems as they are currently built and managed by Southern California Edison (SCE). It uses process-based life cycle assessment (LCA) according to ISO 14044 (2006) and SCE-specific primary data to the extent possible. Potential environmental impacts have been calculated using a wide range of midpoint indicators, and robustness of the results has been investigated through sensitivity analysis of the most uncertain and potentially significant parameters. The studied underground system has higher environmental impacts in all indicators and for all parameter values, mostly due to its higher material intensity. For both systems and all indicators the majority of impact occurs during cable production. Promising strategies for impact reduction are thus cable failure rate reduction for overhead and cable lifetime extension for underground systems.

  20. Catchment power and the joint distribution of elevation and travel distance to the outlet

    NASA Astrophysics Data System (ADS)

    Sklar, Leonard S.; Riebe, Clifford S.; Lukens, Claire E.; Bellugi, Dino

    2016-10-01

    The delivery of water, sediment, and solutes by catchments is influenced by the distribution of source elevations and their travel distances to the outlet. For example, elevation affects the magnitude and phase of precipitation, as well as the climatic factors that govern rock weathering, which influence the production rate and initial particle size of sediments. Travel distance, in turn, affects the timing of flood peaks at the outlet and the degree of sediment size reduction by wear, which affects particle size distributions at the outlet. The distributions of elevation and travel distance have been studied extensively but separately, as the hypsometric curve and width function. Yet a catchment can be considered as a collection of points, each with paired values of elevation and travel distance. For every point, the ratio of elevation to travel distance defines the mean slope for transport of mass to the outlet. Recognizing that mean slope is proportional to the average rate of loss of potential energy by water and sediment during transport to the outlet, we use the joint distribution of elevation and travel distance to define two new metrics for catchment geometry: "source-area power", and the corresponding catchment-wide integral "catchment power". We explore patterns in source-area and catchment power across three study catchments spanning a range of relief and drainage area. We then develop an empirical algorithm for generating synthetic source-area power distributions, which can be parameterized with data from natural catchments. This new way of quantifying the three-dimensional geometry of catchments can be used to explore the effects of topography on the distribution on fluxes of water, sediment, isotopes, and other landscape products passing through catchment outlets, and may provide a fresh perspective on problems of both practical and theoretical interest.

  1. Cleaning ability and induced dentin loss of a magnetostrictive ultrasonic instrument at different power settings.

    PubMed

    Lampe Bless, Kathrin; Sener, Beatrice; Dual, Jürg; Attin, Thomas; Schmidlin, Patrick R

    2011-04-01

    Some laboratory studies have evaluated the oscillation mode of ultrasonic scalers. None of them recorded its influence on calculus removal and quantified dental hard tissue loss. This study aimed to compare the performance of a magnetostrictive ultrasonic instrument at different power settings in vitro in relation to the tip oscillation activity. The oscillation activity of the straight Slimline® insert in the Cavitron® ultrasonic scaling device was analyzed at five different power settings with the help of two laser vibrometers. The performance of this instrument was tested on 60 roots of human single-rooted teeth. Twelve roots each were randomly assigned to be instrumented at a given power setting. Every root was instrumented for 120 s at a standardized instrumentation force of 0.1 ± 0.05 N. In addition, another 30 periodontally involved roots with subgingival calculus were instrumented accordingly to assess the calculus removal potential. The surface characteristics after instrumentation were analyzed under scanning electron microscope. The instrumentation at minimum power setting resulted in an mean increase of the root surface roughness of 0.18 ± 0.28 compared to 0.51 ± 0.48 at maximum power setting (P = 0.0327). The loss of dental hard tissue amounted to 11.37 ± 3.64 at minimum compared to 23.37 ± 15.76 at maximum power (P = 0.0010). The higher the power setting, the more calculus was removed. The values of the latter ranged between 4.04 ± 1.87 and 11.26 ± 4.66 mm² of cleaned dentin surface area (P = 0.0065). At lower power settings, a more favorable relation between cleaning ability, loss of dentine, and surface roughness was found.

  2. Time series power flow analysis for distribution connected PV generation.

    SciTech Connect

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  3. An estimation method of the fault wind turbine power generation loss based on correlation analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Tao; Zhu, Shourang; Wang, Wei

    2017-01-01

    A method for estimating the power generation loss of a fault wind turbine is proposed in this paper. In this method, the wind speed is estimated and the estimated value of the loss of power generation is given by combining the actual output power characteristic curve of the wind turbine. In the wind speed estimation, the correlation analysis is used, and the normal operation of the wind speed of the fault wind turbine is selected, and the regression analysis method is used to obtain the estimated value of the wind speed. Based on the estimation method, this paper presents an implementation of the method in the monitoring system of the wind turbine, and verifies the effectiveness of the proposed method.

  4. A Multi-Agent Design for Power Distribution Systems Automation

    NASA Astrophysics Data System (ADS)

    Ghorbani, M. Jawad

    A new Multi Agent System (MAS) design for fault location, isolation and restoration in power distribution systems is presented. In proposed approach, when there is a fault in the Power Distribution System (PDS), MAS quickly isolates the fault and restores the service to fault-free zones. Hierarchical coordination strategy is introduced to manage the agents which integrate the advantages of both centralized and decentralized coordination strategies. In this framework, Zone Agent (ZA) locate and isolate the fault based on the locally available information and assist the Feeder Agent (FA) for reconfiguration and restoration. FA can solve the restoration problem using the existing algorithms for the 0-1 Knapsack problem. A novel Q-learning mechanism is also introduced to support the FAs in decision making for restoration. Also a distributed MAS-Based Load Shedding (LS) technique has been used to supply as many of higher priority customers as possible, in case there is more demand than generation. The design is illustrated by the use of simulation case studies for fault location, isolation and restoration on West Virginia Super Circuit (WVSC) and hardware implementation for fault location and isolation in a laboratory platform. The results from the case studies indicate the performance of proposed MAS designs.

  5. Power-law distributions from additive preferential redistributions

    NASA Astrophysics Data System (ADS)

    Ree, Suhan

    2006-02-01

    We introduce a nongrowth model that generates the power-law distribution with the Zipf exponent. There are N elements, each of which is characterized by a quantity, and at each time step these quantities are redistributed through binary random interactions with a simple additive preferential rule, while the sum of quantities is conserved. The situation described by this model is similar to those of closed N -particle systems when conservative two-body collisions are only allowed. We obtain stationary distributions of these quantities both analytically and numerically while varying parameters of the model, and find that the model exhibits the scaling behavior for some parameter ranges. Unlike well-known growth models, this alternative mechanism generates the power-law distribution when the growth is not expected and the dynamics of the system is based on interactions between elements. This model can be applied to some examples such as personal wealths, city sizes, and the generation of scale-free networks when only rewiring is allowed.

  6. Chemical Distribution and Bonding of Lithium in Intercalated Graphite: Identification with Optimized Electron Energy Loss Spectroscopy

    SciTech Connect

    Wang, Feng; Graetz, Jason; Moreno, M. Sergio; Ma, Chao; Wu, Lijun; Volkov, Vyacheslav; Zhu, Yimei

    2011-01-10

    Direct mapping of the lithium spatial distribution and the chemical state provides critical information on structure-correlated lithium transport in electrode materials for lithium batteries. Nevertheless, probing lithium, the lightest solid element in the periodic table, poses an extreme challenge with traditional X-ray or electron scattering techniques due to its weak scattering power and vulnerability to radiation damage. Here, we report nanoscale maps of the lithium spatial distribution in electrochemically lithiated graphite using electron energy loss spectroscopy in the transmission electron microscope under optimized experimental conditions. The electronic structure of the discharged graphite was obtained from the near-edge fine structure of the Li and C K-edges and ab initio calculations. A 2.7 eV chemical shift of the Li K-edge, along with changes in the density of states, reveals the ionic nature of the intercalated lithium with significant charge transfer to the graphene sheets. Direct mapping of lithium in graphite revealed nanoscale inhomogeneities (nonstoichiometric regions), which are correlated with local phase separation and structural disorder (i.e., lattice distortion and dislocations) as observed by high-resolution transmission electron microscopy. The surface solid-electrolyte interphase (SEI) layer was also imaged and determined to have a thickness of 10-50 nm, covering both edge and basal planes with LiF as its primary inorganic component. The Li K-edge spectroscopy and mapping, combined with electron microscopy-based structural analysis provide a comprehensive view of the structure-correlated lithium intercalation in graphite and of the formation of the SEI layer.

  7. Chemical Distribution and Bonding of Lithium in Intercalated Graphite: Identification with Optimized Electron Energy Loss Spectroscopy

    SciTech Connect

    Zhu, Y.; Wang, F.; Graetz, J.; Moreno, M.S.; Ma, C.; Wu, L.; Volkov, V.

    2011-02-01

    Direct mapping of the lithium spatial distribution and the chemical state provides critical information on structure-correlated lithium transport in electrode materials for lithium batteries. Nevertheless, probing lithium, the lightest solid element in the periodic table, poses an extreme challenge with traditional X-ray or electron scattering techniques due to its weak scattering power and vulnerability to radiation damage. Here, we report nanoscale maps of the lithium spatial distribution in electrochemically lithiated graphite using electron energy loss spectroscopy in the transmission electron microscope under optimized experimental conditions. The electronic structure of the discharged graphite was obtained from the near-edge fine structure of the Li and C K-edges and ab initio calculations. A 2.7 eV chemical shift of the Li K-edge, along with changes in the density of states, reveals the ionic nature of the intercalated lithium with significant charge transfer to the graphene sheets. Direct mapping of lithium in graphite revealed nanoscale inhomogeneities (nonstoichiometric regions), which are correlated with local phase separation and structural disorder (i.e., lattice distortion and dislocations) as observed by high-resolution transmission electron microscopy. The surface solid-electrolyte interphase (SEI) layer was also imaged and determined to have a thickness of 10-50 nm, covering both edge and basal planes with LiF as its primary inorganic component. The Li K-edge spectroscopy and mapping, combined with electron microscopy-based structural analysis provide a comprehensive view of the structure-correlated lithium intercalation in graphite and of the formation of the SEI layer.

  8. Synthesis of a low loss Mn-Zn ferrite for power applications

    NASA Astrophysics Data System (ADS)

    Tsakaloudi, Vasiliki; Zaspalis, Vassilios

    2016-02-01

    Current market trends of the switching power supplies industry require even lower energy losses in power conversion systems with maintenance of satisfactory initial permeability levels. Typical operation conditions refer to a frequency of 100 kHz, an induction level of 200 mT and a steady state temperature of 100° C. In this work the development of a polycrystalline Mn-Zn ferrite material that exhibits initial relative magnetic permeability above 2500 and very low power losses at 100 kHz, 200 mmT and 100° C is presented. The Mn-Zn ferrite samples were prepared by the conventional solid state reaction method. Sintering was performed under controlled atmosphere conditions. The combinatorial role of TiO2 and CoO together with Zn content, as well as the effects of the process parameters on the magnetic performance of the Mn-Zn ferrite was evaluated. It is shown that the development of the adequate polycrystalline microstructure that is characterized by (a) high sintered density, (b) homogenous grain size that is free of morphological or chemical pinning defects and (c) high resistivity grain boundary structure, can be achieved by means of appropriate compositional and dopant adjustment, anisotropy control and specific resistivity optimization. The newly developed Mn-Zn ferrite is characterized by high sintered density of 4.91 g/cm3, initial magnetic permeability of 2512 (at 10 kHz, 0.1 mT, 25 °C), high saturation magnetic flux density of 560 mT (at 10 kHz, 1200 A/m, 25 °C) and very low power losses (Pv) of 224 mW/cm3 (at 100 kHz, 200 mT, 100 °C) combined with very low power losses of 470 mW/cm3 even at room temperature, establishing it as ideal for power applications.

  9. A distributed control approach for power and energy management in a notional shipboard power system

    NASA Astrophysics Data System (ADS)

    Shen, Qunying

    The main goal of this thesis is to present a power control module (PCON) based approach for power and energy management and to examine its control capability in shipboard power system (SPS). The proposed control scheme is implemented in a notional medium voltage direct current (MVDC) integrated power system (IPS) for electric ship. To realize the control functions such as ship mode selection, generator launch schedule, blackout monitoring, and fault ride-through, a PCON based distributed power and energy management system (PEMS) is developed. The control scheme is proposed as two-layer hierarchical architecture with system level on the top as the supervisory control and zonal level on the bottom as the decentralized control, which is based on the zonal distribution characteristic of the notional MVDC IPS that was proposed as one of the approaches for Next Generation Integrated Power System (NGIPS) by Norbert Doerry. Several types of modules with different functionalities are used to derive the control scheme in detail for the notional MVDC IPS. Those modules include the power generation module (PGM) that controls the function of generators, the power conversion module (PCM) that controls the functions of DC/DC or DC/AC converters, etc. Among them, the power control module (PCON) plays a critical role in the PEMS. It is the core of the control process. PCONs in the PEMS interact with all the other modules, such as power propulsion module (PPM), energy storage module (ESM), load shedding module (LSHED), and human machine interface (HMI) to realize the control algorithm in PEMS. The proposed control scheme is implemented in real time using the real time digital simulator (RTDS) to verify its validity. To achieve this, a system level energy storage module (SESM) and a zonal level energy storage module (ZESM) are developed in RTDS to cooperate with PCONs to realize the control functionalities. In addition, a load shedding module which takes into account the reliability

  10. Power system voltage stability and agent based distribution automation in smart grid

    NASA Astrophysics Data System (ADS)

    Nguyen, Cuong Phuc

    2011-12-01

    negotiation. Communication latency is modeled using a user-defined probability density function. Failure-tolerant communication strategies are developed for agent communications. Major elements of advanced DA are developed in a completely distributed way and successfully tested for several IEEE standard systems, including: Fault Detection, Location, Isolation, and Service Restoration (FLISR); Coordination of Distributed Energy Storage Systems (DES); Distributed Power Flow (DPF); Volt-VAR Control (VVC); and Loss Reduction (LR).

  11. Power loss characteristics of a sensing element based on a polymer optical fiber under cyclic tensile elongation.

    PubMed

    Chen, Yung-Chuan; Chen, Li-Wen; Lu, Wei-Hua

    2011-01-01

    In this study, power losses in polymer optical fiber (POF) subjected to cyclic tensile loadings are studied experimentally. The parameters discussed are the cyclic load level and the number of cycles. The results indicate that the power loss in POF specimens increases with increasing load level or number of cycles. The power loss can reach as high as 18.3% after 100 cyclic loadings. Based on the experimental results, a linear equation is proposed to estimate the relationship between the power loss and the number of cycles. The difference between the estimated results and the experimental results is found to be less than 3%.

  12. Numerical power balance and free energy loss analysis for solar cells including optical, thermodynamic, and electrical aspects

    SciTech Connect

    Greulich, Johannes Höffler, Hannes; Würfel, Uli; Rein, Stefan

    2013-11-28

    A method for analyzing the power losses of solar cells is presented, supplying a complete balance of the incident power, the optical, thermodynamic, and electrical power losses and the electrical output power. The involved quantities have the dimension of a power density (units: W/m{sup 2}), which permits their direct comparison. In order to avoid the over-representation of losses arising from the ultraviolet part of the solar spectrum, a method for the analysis of the electrical free energy losses is extended to include optical losses. This extended analysis does not focus on the incident solar power of, e.g., 1000 W/m{sup 2} and does not explicitly include the thermalization losses and losses due to the generation of entropy. Instead, the usable power, i.e., the free energy or electro-chemical potential of the electron-hole pairs is set as reference value, thereby, overcoming the ambiguities of the power balance. Both methods, the power balance and the free energy loss analysis, are carried out exemplarily for a monocrystalline p-type silicon metal wrap through solar cell with passivated emitter and rear (MWT-PERC) based on optical and electrical measurements and numerical modeling. The methods give interesting insights in photovoltaic (PV) energy conversion, provide quantitative analyses of all loss mechanisms, and supply the basis for the systematic technological improvement of the device.

  13. The influence of bromazepam on cortical power distribution.

    PubMed

    Sampaio, Isabel; Puga, Fernanda; Veiga, Heloisa; Cagy, Mauricio; Piedade, Roberto; Ribeiro, Pedro

    2008-06-01

    The EEG has been widely employed in the assessment of electrophysiological changes induced by distinct medications. Its sensibility in detecting alterations produced by a specific substance may be enhanced by methods of quantitative analyses (qEEG). The present study aimed at investigating the modulatory effects of bromazepam on brain dynamics. The effects of bromazepam (3 mg) on EEG power distribution were tested in 10 healthy individuals, in a double-blind experiment. The electrophysiological measure was analyzed across experimental conditions, moments, and electrodes, in the delta, theta, alpha and beta frequency bands separately. A significant decrease of relative power was observed in delta and theta (main effect of condition). No interactions were observed. Although the expected anxiolytic EEG profile was not observed (increased beta and decreased alpha activity), this specific result may be related to other factors such as dosage used and the subjects' general physiological state, and not necessarily to the drug itself.

  14. Tomographic determination of the power distribution in electron beams

    DOEpatents

    Teruya, Alan T.; Elmer, John W.

    1996-01-01

    A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process.

  15. Operational maintenance data for power generation distribution and HVAC components

    SciTech Connect

    Hollis, H.D.; Hale, P.S. Jr.; Arno, R.G.; Briggs, S.J.

    1995-12-31

    This paper describes the culmination of a 24,000 man hour effort to collect operational and maintenance data on 239 power generation, power distribution and HVAC items, including gas turbine generators, diesel engine generators, switch gear assemblies, cables, boilers, piping, valves and chillers. This program was designed to determine the effects of new technology equipment, i.e., equipment installed after 1971, on availability. The central hypothesis was that this new equipment would exhibit a significant increase in availability, with corresponding decreases in required maintenance and the occurrence of failures. Information was obtained on a variety of commercial and industrial facility types (including office buildings, hospitals, water treatment facilities, prisons, utilities, manufacturing facilities, school universities and bank computer centers), with varying degrees of maintenance quality.

  16. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh; Faress Rahman

    2002-12-31

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC during the October 2002 to December 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The following activities have been carried out during this reporting period: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} Part-load performance analysis was conducted {lg_bullet} Primary system concept was down-selected {lg_bullet} Dynamic control model has been developed {lg_bullet} Preliminary heat exchanger designs were prepared {lg_bullet} Pressurized SOFC endurance testing was performed

  17. Thermal Diagnosis of Rural Power Grid Distribution Substation Electrical Joints

    NASA Astrophysics Data System (ADS)

    Ge, Le-Yi; Wang, Yue-Xin; Qiao, Yu-Jing

    2016-05-01

    Rural Power Grid Distribution Substation (RPGDS) in long-term operation process, often due to thermal power of the high voltage unit is very big, which leads to serious local heat. In order to ensure the stability, security and reliability, it is necessary to measure and detect for some specific electrical joints of RPGDS. This paper presents a novel diagnosis method based on infrared thermal imaging technology for the specific electrical joints, the method obtains the original infrared thermal image firstly, then carries out following steps as: preprocessing, noise filtering, image enhancement, and extract image edge line, finally, analyzes the results of infrared thermal image data processing. This novel method not only overcomes the shortcomings of traditional contact measurement methods, but can realize fault diagnose more accurately for the electrical joints.

  18. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh

    2004-07-04

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the January to June 2004 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  19. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Faress Rahman; Nguyen Minh

    2004-01-04

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the July 2003 to December 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  20. Tomographic determination of the power distribution in electron beams

    DOEpatents

    Teruya, A.T.; Elmer, J.W.

    1996-12-10

    A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams is disclosed. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process. 4 figs.

  1. Single-phase power distribution system power flow and fault analysis

    NASA Technical Reports Server (NTRS)

    Halpin, S. M.; Grigsby, L. L.

    1992-01-01

    Alternative methods for power flow and fault analysis of single-phase distribution systems are presented. The algorithms for both power flow and fault analysis utilize a generalized approach to network modeling. The generalized admittance matrix, formed using elements of linear graph theory, is an accurate network model for all possible single-phase network configurations. Unlike the standard nodal admittance matrix formulation algorithms, the generalized approach uses generalized component models for the transmission line and transformer. The standard assumption of a common node voltage reference point is not required to construct the generalized admittance matrix. Therefore, truly accurate simulation results can be obtained for networks that cannot be modeled using traditional techniques.

  2. EMC and power quality standards for 20-kHz power distribution

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1987-01-01

    The Space Station Power Distribution System has been baselined as a sinusoidal single phase, 440 VRMS system. This system has certain unique characteristics directly affecting its application. In particular, existing systematic description and control documents were modified to reflect the high operating frequency. This paper will discuss amendments made on Mil STD 704 (Electrical Power Characteristics), and Mil STD 461-B (Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference). In some cases these amendments reflect changes of several orders of magnitude. Implications and impacts of these changes are discussed.

  3. Practical experience with the input/loss method as applied to a CFB power plant

    SciTech Connect

    Deihl, B.; Lang, F.D.

    1999-07-01

    In late 1995 the Input/Loss Method was installed for on-line monitoring of an independent power producer located in Colver, PA. Colver is a 115 MWe Circulating Fluidized Bed (CFB) steam generator burning poor quality coal, having typically {+-}20% variation in As-Fired heating value, providing considerable difficulties to operating staff. The Input/Loss Method provides a complete thermal understanding of a power plant through explicit determinations of fuel flow, emission flows, fuel chemistry, fuel heating value and thermal efficiency. Direct measurements of fuel or emission flows are not made. In addition, the Method employs a Fuel Consumption Index (FCI) technology to alert the operator as to which components/processes within the system have higher irreversible losses--in terms of higher fuel consumptions for a given power level--thus where improved heat rate can be found. The Method also uses a Sulfur Function Optimizer (SFO) parameter, which assist the operator in minimizing the use of limestone, while meeting regulatory SO{sub 2} effluents. This paper discusses a number of actual operational situations, taken over the past four years, which were resolved with the help of the Input/Loss Method. For example: the usefulness of the SFO parameter, tracking FCI for key processes, plant-evaluated economics, etc. Problems with required effluent (CEMS) instrumentation, experience with a CEMS error analysis procedure, stoichiometric assumptions, air leakage assumptions, etc. are discussed.

  4. SuperPower's Second Generation HTS Conductor Design for Stability and Low AC Losses

    NASA Astrophysics Data System (ADS)

    Hazelton, D. W.; Xie, Y. Y.; Qiao, Y.; Zhang, E.; Selvamanickam, V.

    2006-03-01

    SuperPower is developing a conductor design for improved mechanical properties, quench stability, and low ac losses. Coated conductors are typically 12 mm wide with a few microns of silver overlayer. SuperPower's design modifies such base conductor designs into geometries more suited for practical applications. Wide conductors are slit into 4 mm wide tapes, in particular for cable applications, but also to reduce ac losses. After slitting, the conductor is stabilized with approximately 20 microns of surround copper stabilizer, completely encapsulating the conductor and providing a hermetic seal. Other advantages of the surround copper stabilizer configuration are rounded edges for dielectric integration and superior over-current handling capability (9X critical current with 300 ms wide pulses). Prototype 1 m cables made by Sumitomo Electric using this practical conductor showed total ac losses under 0.4 W/kA-m. To further reduce ac losses, especially for high frequency applications of the military, SuperPower's conductor design involves striating the current-carrying layers by a photolithography process. Several racetrack coils made with our practical coated conductors have been provided to Rockwell Automation for use in a demonstration motor. Recent results of our practical coated conductor will be discussed.

  5. Signal losses with real-time three-dimensional power Doppler imaging.

    PubMed

    Garcia, Damien; Fenech, Marianne; Qin, Zhao; Soulez, Gilles; Cloutier, Guy

    2007-10-01

    Power Doppler imaging (PDI) has been shown to be influenced by the wall filter when assessing arterial stenoses. Real-time 3-D Doppler imaging may likely become a widespread practice in the near future, but how the wall filter could affect PDI during the cardiac cycle has not been investigated. The objective of the study was to demonstrate that the wall filter may produce unexpected major signal losses in real-time 3-D PDI. To test our hypothesis, we first validated binary images obtained from analytical simulations with in vitro PDI acquisitions performed in a tube under pulsatile flow conditions. We then simulated PDI images in the presence of a severe stenosis, considering physiological conditions by finite element modeling. Power Doppler imaging simulations revealed important signal losses within the lumen area at different instants of the flow cycle, and there was a very good concordance between measured and predicted PDI binary images in the tube. Our results show that the wall filter may induce severe PDI signal losses that could negatively influence the assessment of vascular stenosis. Clinicians should therefore be aware of this cause of signal loss to properly interpret power Doppler angiographic images.

  6. Reactive Power and Voltage Optimization Control Strategy in Active Distribution Network Based on the Determination of the Key Nodes

    NASA Astrophysics Data System (ADS)

    Meng, Qingmeng; Che, Renfei; Gao, Shi

    2017-05-01

    The distributed generation which is integrated in the active distribution network changes power flow, bringing new challenges to the voltage control. When voltage limit violation happens, in order to make the voltage return to normal range and improve the voltage quality, a novel voltage control strategy is proposed. Considering the voltage quality and node importance, the electrical closeness centrality and key node contribution degree are defined, and the key nodes are determined by the orders of the key node contribution degree. This paper uses the reactive power compensation devices which are installed at the key nodes coordinated with the reactive power output of the distributed generation to realize the voltage optimization control. The voltage optimization control model is established by taking the minimum power loss as an objective function. Using the particle swarm optimization algorithm solves the model. The simulation results of the improved IEEE-33 bus system verify the effectiveness of the proposed method.

  7. Space Station module Power Management And Distribution (PMAD) system

    NASA Technical Reports Server (NTRS)

    Walls, Bryan

    1990-01-01

    This project consists of several tasks which are unified toward experimentally demonstrating the operation of a highly autonomous, user-supportive power management and distribution system for Space Station Freedom (SSF) habitation/laboratory modules. This goal will be extended to a demonstration of autonomous, cooperative power system operation for the whole SSF power system through a joint effort with NASA's Lewis Research Center, using their Autonomous Power System. Short term goals for the space station module power management and distribution include having an operational breadboard reflecting current plans for SSF, improving performance of the system communications, and improving the organization and mutability of the artificial intelligence (AI) systems. In the middle term, intermediate levels of autonomy will be added, user interfaces will be modified, and enhanced modeling capabilities will be integrated in the system. Long term goals involve conversion of all software into Ada, vigorous verification and validation efforts and, finally, seeing an impact of this research on the operation of SSF. Conversion of the system to a DC Star configuration is now in progress, and should be completed by the end of October, 1989. This configuration reflects the latest SSF module architecture. Hardware is now being procured which will improve system communications significantly. The Knowledge-Based Management System (KBMS) is initially developed and the rules from FRAMES have been implemented in the KBMS. Rules in the other two AI systems are also being grouped modularly, making them more tractable, and easier to eventually move into the KBMS. Adding an intermediate level of autonomy will require development of a planning utility, which will also be built using the KBMS. These changes will require having the user interface for the whole system available from one interface. An Enhanced Model will be developed, which will allow exercise of the system through the interface

  8. Automated fault location and diagnosis on electric power distribution feeders

    SciTech Connect

    Zhu, J.; Lubkeman, D.L.; Girgis, A.A.

    1997-04-01

    This paper presents new techniques for locating and diagnosing faults on electric power distribution feeders. The proposed fault location and diagnosis scheme is capable of accurately identifying the location of a fault upon its occurrence, based on the integration of information available from disturbance recording devices with knowledge contained in a distribution feeder database. The developed fault location and diagnosis system can also be applied to the investigation of temporary faults that may not result in a blown fuse. The proposed fault location algorithm is based on the steady-state analysis of the faulted distribution network. To deal with the uncertainties inherent in the system modeling and the phasor estimation, the fault location algorithm has been adapted to estimate fault regions based on probabilistic modeling and analysis. Since the distribution feeder is a radial network, multiple possibilities of fault locations could be computed with measurements available only at the substation. To identify the actual fault location, a fault diagnosis algorithm has been developed to prune down and rank the possible fault locations by integrating the available pieces of evidence. Testing of the developed fault location and diagnosis system using field data has demonstrated its potential for practical use.

  9. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    SciTech Connect

    Perkins, R. J.; Ahn, Joonwook; Bell, R. E.; Bertelli, Nicola; Diallo, A.; Gerhardt, S.; Gray, T. K.; Green, David L; Jaeger, E. F.; Hosea, J.; Jaworski, M. A.; LeBlanc, B; Kramer, G.; McLean, Adam G; Maingi, Rajesh; Phillips, C. K.; Podesta, M.; Ryan, Philip Michael; Sabbagh, S. A.; Scotti, F.; Taylor, G.; Wilson, J. R.

    2013-01-01

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  10. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    SciTech Connect

    Perkins, R. J.; Bell, R. E.; Bertelli, N.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; LeBlanc, B. P.; Kramer, G. J.; Maingi, R.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Scotti, F.; Taylor, G.; Wilson, J. R.; Ahn, J-W.; Gray, T. K.; Green, D. L.; McLean, A.; and others

    2014-02-12

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  11. Effect of power distribution on the weld quality during hybrid laser welding of an Al-Mg alloy

    NASA Astrophysics Data System (ADS)

    Leo, P.; Renna, G.; Casalino, G.; Olabi, A. G.

    2015-10-01

    This paper treats of the analysis of the effect of arc and laser powers on the quality of the arc assisted fiber laser welding of an Al-Mg alloy in the butt configuration. Grain size, weld geometry defects, porosity, and magnesium loss were measured. Magnesium content of the fused zone decreased as the laser power increased while the porosity increased with laser power. Microhardness profiles and tensile properties were explained on the basis of the joint microstructure and defects and related to the power distribution. The porosity level and Mg content in the fused zone affected both tensile strength and ductility. The power distribution that stabilized the welding process and minimize the weld porosity was defined.

  12. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    PubMed Central

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC. PMID:26792556

  13. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    NASA Astrophysics Data System (ADS)

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.

  14. Using reanalysis data for the prediction of seasonal wind turbine power losses due to icing

    NASA Astrophysics Data System (ADS)

    Burtch, Daniel G.

    The Northern Plains region of the United States is home to a significant amount of potential wind energy. However, in winter months capturing this potential power is severely impacted by the meteorological conditions, in the form of icing. Predicting the expected loss in power production due to icing is a valuable parameter that can be used in wind turbine operations, determination of wind turbine site locations and long-term energy estimates which are used for financing purposes. Currently, losses due to icing must be estimated when developing predictions for turbine feasibility and financing studies, while icing maps, a tool commonly used in Europe, are lacking in the United States. This study uses the Modern-Era Retrospective Analysis for Research and Applications (MERRA) dataset in conjunction with turbine production data and in-situ wind measurements to investigate six methods of predicting seasonal losses (October-March) due to icing at two sites located in Petersburg, ND and Valley City, ND. The prediction of icing losses is based on temperature and relative humidity thresholds and is accomplished using six methods. Three methods use a Measure-Correlate-Predict (MCP) and flow model (WAsP) analysis for the determination of wind speeds and MERRA for temperature and relative humidity, while three methods use MERRA for all three variables. For each season from 2002 to 2010, the predicted losses due to icing are determined for a range of relative humidity thresholds and compared with observed icing losses. An optimal relative humidity is then determined and tested on all seasons from 2002 to 2013. The prediction methods are then compared to a common practice used in the wind energy industry of assuming a constant percentage loss for icing over the same time period. The three methods using MERRA data alone show severe deficiencies in the accurate determination of wind speeds which leads to a large underprediction in accurate power output. Of the three MCP

  15. Microscale air quality impacts of distributed power generation facilities.

    PubMed

    Olaguer, Eduardo P; Knipping, Eladio; Shaw, Stephanie; Ravindran, Satish

    2016-08-01

    The electric system is experiencing rapid growth in the adoption of a mix of distributed renewable and fossil fuel sources, along with increasing amounts of off-grid generation. New operational regimes may have unforeseen consequences for air quality. A three-dimensional microscale chemical transport model (CTM) driven by an urban wind model was used to assess gaseous air pollutant and particulate matter (PM) impacts within ~10 km of fossil-fueled distributed power generation (DG) facilities during the early afternoon of a typical summer day in Houston, TX. Three types of DG scenarios were considered in the presence of motor vehicle emissions and a realistic urban canopy: (1) a 25-MW natural gas turbine operating at steady state in either simple cycle or combined heating and power (CHP) mode; (2) a 25-MW simple cycle gas turbine undergoing a cold startup with either moderate or enhanced formaldehyde emissions; and (3) a data center generating 10 MW of emergency power with either diesel or natural gas-fired backup generators (BUGs) without pollution controls. Simulations of criteria pollutants (NO2, CO, O3, PM) and the toxic pollutant, formaldehyde (HCHO), were conducted assuming a 2-hr operational time period. In all cases, NOx titration dominated ozone production near the source. The turbine scenarios did not result in ambient concentration enhancements significantly exceeding 1 ppbv for gaseous pollutants or over 1 µg/m(3) for PM after 2 hr of emission, assuming realistic plume rise. In the case of the datacenter with diesel BUGs, ambient NO2 concentrations were enhanced by 10-50 ppbv within 2 km downwind of the source, while maximum PM impacts in the immediate vicinity of the datacenter were less than 5 µg/m(3). Plausible scenarios of distributed fossil generation consistent with the electricity grid's transformation to a more flexible and modernized system suggest that a substantial amount of deployment would be required to significantly affect air quality on

  16. Distributed Optimal Power and Rate Control in Wireless Sensor Networks

    PubMed Central

    Tang, Meiqin; Bai, Jianyong; Li, Jing; Xin, Yalin

    2014-01-01

    With the rapid development of wireless sensor networks, reducing energy consumption is becoming one of the important factors to extend node lifetime, and it is necessary to adjust the launching power of each node because of the limited energy available to the sensor nodes in the networks. This paper proposes a power and rate control model based on the network utility maximization (NUM) framework, where a weighting factor is used to reflect the influence degree of the sending power and transmission rate to the utility function. In real networks, nodes interfere with each other in the procedure of transmitting signal, which may lead to signal transmission failure and may negatively have impacts on networks throughput. Using dual decomposition techniques, the NUM problem is decomposed into two distributed subproblems, and then the conjugate gradient method is applied to solve the optimization problem with the calculation of the Hessian matrix and its inverse in order to guarantee fast convergence of the algorithm. The convergence proof is also provided in this paper. Numerical examples show that the proposed solution achieves significant throughput compared with exiting approaches. PMID:24895654

  17. Fuel cycle comparison of distributed power generation technologies.

    SciTech Connect

    Elgowainy, A.; Wang, M. Q.; Energy Systems

    2008-12-08

    The fuel-cycle energy use and greenhouse gas (GHG) emissions associated with the application of fuel cells to distributed power generation were evaluated and compared with the combustion technologies of microturbines and internal combustion engines, as well as the various technologies associated with grid-electricity generation in the United States and California. The results were primarily impacted by the net electrical efficiency of the power generation technologies and the type of employed fuels. The energy use and GHG emissions associated with the electric power generation represented the majority of the total energy use of the fuel cycle and emissions for all generation pathways. Fuel cell technologies exhibited lower GHG emissions than those associated with the U.S. grid electricity and other combustion technologies. The higher-efficiency fuel cells, such as the solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC), exhibited lower energy requirements than those for combustion generators. The dependence of all natural-gas-based technologies on petroleum oil was lower than that of internal combustion engines using petroleum fuels. Most fuel cell technologies approaching or exceeding the DOE target efficiency of 40% offered significant reduction in energy use and GHG emissions.

  18. Distributed optimal power and rate control in wireless sensor networks.

    PubMed

    Tang, Meiqin; Bai, Jianyong; Li, Jing; Xin, Yalin

    2014-01-01

    With the rapid development of wireless sensor networks, reducing energy consumption is becoming one of the important factors to extend node lifetime, and it is necessary to adjust the launching power of each node because of the limited energy available to the sensor nodes in the networks. This paper proposes a power and rate control model based on the network utility maximization (NUM) framework, where a weighting factor is used to reflect the influence degree of the sending power and transmission rate to the utility function. In real networks, nodes interfere with each other in the procedure of transmitting signal, which may lead to signal transmission failure and may negatively have impacts on networks throughput. Using dual decomposition techniques, the NUM problem is decomposed into two distributed subproblems, and then the conjugate gradient method is applied to solve the optimization problem with the calculation of the Hessian matrix and its inverse in order to guarantee fast convergence of the algorithm. The convergence proof is also provided in this paper. Numerical examples show that the proposed solution achieves significant throughput compared with exiting approaches.

  19. An Efficacious Multi-Objective Fuzzy Linear Programming Approach for Optimal Power Flow Considering Distributed Generation.

    PubMed

    Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri

    2016-01-01

    This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality.

  20. An Efficacious Multi-Objective Fuzzy Linear Programming Approach for Optimal Power Flow Considering Distributed Generation

    PubMed Central

    Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri

    2016-01-01

    This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality. PMID:26954783

  1. Analysis of Loss-of-Offsite-Power Events 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-02-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. Risk analyses suggest that loss of all alternating current power contributes over 70% of the overall risk at some U.S. nuclear plants. LOOP event and subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1997 through 2013. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. The emergency diesel generator failure modes considered are failure to start, failure to load and run, and failure to run more than 1 hour. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant trends in LOOP frequencies over the 1997–2013 period are identified. There is a possibility that a significant trend in grid-related LOOP frequency exists that is not easily detected by a simple analysis. Statistically significant increases in recovery times after grid- and switchyard-related LOOPs are identified.

  2. Analysis of Loss-of-Offsite-Power Events 1998–2012

    SciTech Connect

    T. E. Wierman

    2013-10-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. Risk analyses performed loss of all alternating current power contributes over 70% of the overall risk at some U.S. nuclear plants. LOOP event and subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience from fiscal year 1998 through 2012. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. The EDG failure modes considered are failure to start, failure to load and run, and failure to run more than 1 hour. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. A statistically significant increase in industry performance was identified for plant-centered and switchyard-centered LOOP frequencies. There is no statistically significant trend in LOOP durations.

  3. AC losses in superconductors with a power-law constitutive relation

    NASA Astrophysics Data System (ADS)

    Agassi, Y. D.

    2015-10-01

    The observed constitutive relation between the electrical field and current density in cuprates high temperature superconductors is a power-law of the current. This functional dependence is presumably related to the giant flux-creep domain. It is shown that this constitutive relation reflects the statistical spread of the pinning potential associated with creep motion of vortex bundles. The AC losses emanating from a power-law constitutive relation are calculated in an approach focused on the superconductor's electric field. For a slab geometry in the presence of a parallel AC magnetic field or transport current, the calculated AC-loss scaling laws are consistent with BSCCO data and the critical state model. Extensions of the approach are briefly discussed.

  4. Compact, low-loss and low-power 8×8 broadband silicon optical switch.

    PubMed

    Chen, Long; Chen, Young-kai

    2012-08-13

    We demonstrated a 8×8 broadband optical switch on silicon for transverse-electrical polarization using a switch-and-selector architecture. The switch has a footprint of only 8 mm × 8 mm, minimum on-chip loss of about 4 dB, and a port-to-port insertion loss variation of only 0.8 dB near some spectral regions. The port-to-port isolation is above 30 dB over the entire 80-nm-wide spectral range or above 45 dB near the central 30 nm. We also demonstrated a switching power of less than 1.5 mW per element and a speed of 2 kHz, and estimated the upper bound of total power consumption to be less than 70 mW even without optimization of the default state of the individual switch elements.

  5. Assessment of technologies for predicting insertion loss and directivity of power plant exhaust systems

    NASA Astrophysics Data System (ADS)

    Cummins, Jim R.; Loewenstein, Marshall

    2005-09-01

    Much technology exists for predicting the insertion loss, directivity and radiation of various components in a power plant. For example, the ASHRAE noise guide gives the IL and/or directivity for many duct configurations. Unfortunately, there are also many components or geometries for which there is currently no practical prediction methodology. The state of the technology for predicting insertion loss, directivity and sound radiation by power plant components, especially ducted sources, such as intake and exhaust, is reviewed with emphasis on modeling techniques and verification. Several cases where the normal prediction methods are both adequate and inadequate are presented. Suggestions are given as to methods and/or future development that could provide more accurate, reliable, or useable results.

  6. Experimental study on guide friction contribution in global power loss of a tooth chain transmission

    NASA Astrophysics Data System (ADS)

    Velicu, R.; Papuc, R.; Gavrila, C. C.; Popa, S.

    2017-02-01

    The subject of the paper is the friction between a tooth chain and the guide. An experimental study is developed with the aim of determining the contribution of chain-guide friction on the global friction of a basic tooth chain transmission. The measurements have been made on a chain friction rig, testing a basic tooth chain transmission with transmission ratio equal to 1, with a controlled tensioning device. The following parameters can be adjusted and measured: rotational speed, tensioning force in the chain, position of the guide, temperature and pressure of the oil used for lubrication. Friction torque at the input shaft is a sum of friction torques coming from bearings, chain and guide. The paper presents the contribution of the guide in the power loss by friction, as percent of the power loss from friction in chain and guide together. Influences of speed, tensioning force and oil temperature are presented.

  7. Polarizing Field and Particle Concentration Dependence of the Magnetic Loss Power in Ferrofluids

    NASA Astrophysics Data System (ADS)

    Fannin, Paul C.; Malaescu, Iosif; Stefu, Nicoleta; Marin, Catalin N.

    2009-05-01

    The frequency (f) and polarizing field (H) dependence of the complex magnetic permeability μ(f,H) = μ'(f,H)-iμ″(f,H), of different magnetic fluid samples, over the range 100 MHz to 6 GHz and 0 to 102.4 kA/m, respectively, were analyzed. Starting from an initial magnetic fluid sample (sample A) with magnetite particles dispersed in kerosene and stabilized with oleic acid, having particle concentration n = 19.16ṡ1022 m-3, three samples were obtained by successive dilution with kerosene (with a dilution ratio 2:3) (samples A1, A2, and A3). Based on the complex magnetic permeability measurements of each sample, and for each field value, values of the specific magnetic loss power were obtained. We have also studied the dependence on particle concentration of the magnetic loss power, both in zero polarizing field and in the presence of the polarizing field.

  8. Power Losses in the ILC 20-Mrad Extraction Line at 1-TeV

    SciTech Connect

    Ferrari, Arnaud; Nosochkov, Yuri; /SLAC

    2007-07-02

    The authors have performed a detailed study of the power losses in the post-collision extraction line of a TeV e{sup +}e{sup -} collider with a crossing angle of 20 mrad at the interaction point. Five cases were considered: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam-beam effects at the interaction point lead to an emittance growth for the outgoing beam, as well as to the production of beamstrahlung photons and e{sup +}e{sup -} coherent pairs. The power losses along the extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular offset at the interaction point.

  9. A Research on Test Platform of Energy-Saving and Loss-Reducing Experiment for Distribution Network

    NASA Astrophysics Data System (ADS)

    Jiang, Li-Min; Yan, Hua-Guang; Meng, Jun-Xia; Yin, Zhong-Dong; Wei, Wen-Si

    2017-05-01

    Based on the study of quantitative energy consumption reduction model, a test platform was established to test and verify the theoretical method. In the experiment, a power supply device with different power quality disturbances is required. This paper proposes a series multi-objective VQDG which can generate typical voltage disturbance, such as flicker, sag or swell, harmonics, unbalance and their superimposition applied to testing load. In the application, the cascade H-bridges inverter is seriesly connected between the gird source and the testing load. The device has two advantages: the output disturbance voltage level is low and the power absorbed by load is mostly provided by grid. Compared with those devices with high power rating, the size of the capacitor of VQDG will be decreased remarkably. The device is designed and physical tests are performed to demonstrate the variety of functions. Therefore, it can provide the power quality disturbance signal for the simulation experiment platform of energy saving and loss reduction of distribution network.

  10. Power law distributions and dynamic behaviour of stock markets

    NASA Astrophysics Data System (ADS)

    Richmond, P.

    2001-04-01

    A simple agent model is introduced by analogy with the mean field approach to the Ising model for a magnetic system. Our model is characterised by a generalised Langevin equation = F ϕ + G ϕ t where t is the usual Gaussian white noise, i.e.: t t' = 2Dδ t-t' and t = 0. Both the associated Fokker Planck equation and the long time probability distribution function can be obtained analytically. A steady state solution may be expressed as P ϕ = exp{ - Ψ ϕ - ln G(ϕ)} where Ψ ϕ = - F/ G dϕ and Z is a normalization factor. This is explored for the simple case where F ϕ = Jϕ + bϕ2 - cϕ3 and fluctuations characterised by the amplitude G ϕ = ϕ + ɛ when it readily yields for ϕ>>ɛ, a distribution function with power law tails, viz: P ϕ = exp{ 2bϕ-cϕ2 /D}. The parameter c ensures convergence of the distribution function for large values of ϕ. It might be loosely associated with the activity of so-called value traders. The parameter J may be associated with the activity of noise traders. Output for the associated time series show all the characteristics of familiar financial time series providing J < 0 and D | J|.

  11. Solar power generation by use of Stirling engine and heat loss analysis of its cavity receiver

    NASA Astrophysics Data System (ADS)

    Hussain, Tassawar

    Since concentrated power generation by Stirling engine has the highest efficiency therefore efficient power generation by concentrated systems using a Stirling engine was a primary motive of this research. A 1 kW Stirling engine was used to generate solar power using a Fresnel lens as a concentrator. Before operating On-Sun test, engine's performance test was conducted by combustion test. Propane gas with air was used to provide input heat to the Stirling Engine and 350W power was generated with 14% efficiency of the engine. Two kinds of receivers were used for On-Sun test, first type was the Inconel tubes with trapped helium gas and the second one was the heat pipe. Heat pipe with sodium as a working fluid is considered the best approach to transfer the uniform heat from the receiver to the helium gas in the heater head of the engine. A Number of On-Sun experiments were performed to generate the power. A minimum 1kW input power was required to generate power from the Stirling engine but it was concluded that the available Fresnel lens was not enough to provide sufficient input to the Stirling engine and hence engine was lagged to generate the solar power. Later on, for a high energy input a Beam Down system was also used to concentrate the solar light on the heater head of the Stirling engine. Beam down solar system in Masdar City UAE, constructed in 2009 is a variation of central receiver plant with cassegrainian optics. Around 1.5kW heat input was achieved from the Beam Down System and it was predicted that the engine receiver at beam down has the significant heat losses of about 900W. These high heat losses were the major hurdles to get the operating temperature (973K) of the heat pipes; hence power could not be generated even during the Beam Down test. Experiments were also performed to find the most suitable Cavity Receiver configuration for maximum solar radiation utilizations by engine receiver. Dimensionless parameter aperture ration (AR=d/D) and aperture

  12. A Novel Voltage Clamped Snubber Circuit Topology Suitable for Multilevel Inverter with Its Lowered Power Loss Performances

    NASA Astrophysics Data System (ADS)

    Yamamoto, Masayoshi; Sato, Shinji; Nakaoka, Mutsuo

    This paper presents a novel prototype of lowered loss snubber circuit topology suitable for multilevel voltage source inverter and rectifier for high power applications. The reduced power loss characteristics and voltage capability performances of the proposed voltage clamped snubber circuit are evaluated in comparison with conventional RCD snubber circuit designed for 4-level voltage source inverter using IGBTs on the basis of experimental results.

  13. Electron Recirculation in Electrostatic Multicusp Systems: 1. Confinement and Losses in Simple Power Law Wells

    DTIC Science & Technology

    1991-04-19

    ELECTROSTATIC MULTICUSP SYSTEMS: I - CONFINEMENT AND LOSSES IN SIMPLE POWER LAW WELLSt Robert W. Bussard and Accesion For Katherine E. King NTIS CRA&I DTIC TAB...9100 A Center Street, Manassas, VA 22110, (703) 330-7990 92-’ 9 q2-f- ,f ELECTRON RECIRCULATION IN ELECTROSTATIC MULTICUSP SYSTEMS: I - CONFINEMENT AND...confinement in Polywellt*-type multicusp systems. These are special polyhedral configurations 6 . 7 that allow formation of stable deep electrostatic

  14. Status of several Stirling loss characterization efforts and their significance for Stirling space power development

    NASA Technical Reports Server (NTRS)

    Tew, Roy C., Jr.

    1988-01-01

    NASA-Lewis and other U.S. Government agencies have supported experimental and analytical programs for the characterization of Stirling cycle engines' thermodynamic losses, with a view to the improvement of Stirling engine design capabilities. The Space Power Demonstrator Engine is noted to have benefited from these efforts; test data and model predictions suggest that even greater performance improvements would be obtainable through additional modifications of engine regenerator and heater hardware.

  15. Power stapes: an alternative method for treating hearing loss in osteogenesis imperfecta?

    PubMed

    Kontorinis, Georgios; Lenarz, Thomas; Mojallal, Hamidreza; Hinze, Anna-Lena; Schwab, Burkard

    2011-06-01

    To present power stapes, stapedotomy, and middle ear implantation with Vibrant SoundBridge (VSB) performed in a one-step surgery as an alternative option for hearing rehabilitation in patients with osteogenesis imperfecta (OI). Retrospective case series. Tertiary referral ear center. A family with genetically proven OI Type I. Two patients, mother and son, with severe to profound mixed hearing loss underwent 3 power stapes, 1 unilateral and 1 bilateral sequential. Thorough audiological diagnostic batteries including aided and unaided pure-tone and free-field audiometry and Freiburg monosyllabic word test were used to assess the preoperative status and the postoperative hearing outcome. High-resolution computed tomography of the temporal bones was performed as well. Surgical procedure and any special considerations were analyzed in detail. The hearing outcome was favorable in all cases, showing in comparison to the preoperative values an average improvement of 36.8 dB. Severe intraoperative bleeding of the middle ear mucosa was the only complication and could be easily controlled by allowing short time intervals. Inner ear trauma did not occur in any case. Power stapes represents a safe and promising procedure for treating hearing loss in selected patients with OI. Furthermore, it introduces a new, advantageous VSB application in cases of mixed hearing loss with severe otosclerosis and increased bone-conduction thresholds.

  16. Design of a power management and distribution system for a thermionic-diode powered spacecraft

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.

    1996-01-01

    The Electrical Systems Development Branch of the Power Technology Division at the NASA Lewis Research Center in Cleveland, Ohio is designing a Power Management and Distribution (PMAD) System for the Air Force's Integrated Solar Upper Stage (ISUS) Engine Ground Test Demonstration (EGD). The ISUS program uses solar-thermal propulsion to perform orbit transfers from Low Earth Orbit (LEO) to Geosynchronous Orbit (GEO) and from LEO to Molnya. The ISUS uses the same energy conversion receiver to perform the LEO to High Earth Orbit (HEO) transfer and to generate on-orbit electric power for the payloads. On-orbit power generation is accomplished via two solar concentrators heating a dual-cavity graphite-core which has Thermionic Diodes (TMD's) encircling each cavity. The graphite core and concentrators together are called the Receiver and Concentrator (RAC). The TDM-emitters reach peak temperatures of approximately 2200K, and the TID-collectors are run at approximately 1000K. Because of the high Specific Impulse (I(sup sp)) of solar thermal propulsion relative to chemical propulsion, and because a common bus is used for communications, GN&C, power, etc., a substantial increase in payload weight is possible. This potentially allows for a stepdown in the required launch vehicle size or class for similar payload weight using conventional chemical propulsion and a separate spacecraft bus. The ISUS power system is to provide 1000W(sub e) at 28+/-6V(sub dc) to the payload/spacecraft from a maximum TID generation capability of 1070W(sub e) at 2200K. Producing power with this quality, protecting the spacecraft from electrical faults and accommodating operational constraints of the TID's are the responsibilities of the PMAD system. The design strategy and system options examined along with the proposed designs for the Flight and EGD configurations are discussed herein.

  17. ELECTRON CYCLOTRON MASER INSTABILITY IN SPACE PLASMAS WITH KAPPA LOSS-CONE DISTRIBUTION

    SciTech Connect

    Tang, J. F.; Wu, D. J.; Yan, Y. H.

    2012-02-01

    It is well known that non-thermal electrons, often modeled by the kappa distribution, are ubiquitously observed in space. Kappa-type distributions have been widely discussed in various plasma environments. On the other hand, when these non-thermal electrons are trapped by magnetic fields in space they frequently have a loss-cone distribution in velocity space. In this paper, we investigated the growth rates of electron cyclotron maser (ECM) instability in space plasmas by using a kappa loss-cone distribution. Based on the cold plasma assumption and weakly relativistic approximation, the results show that non-thermal electrons with such a distribution can excite ECM emission efficiently. The growth rates of O1 and X2 modes both increase with the kappa spectral index ({kappa}) but the growth rate of X2 mode increases slightly more rapidly than that of O1 mode. The present analysis also shows that the growth rates increase rapidly with the loss-cone index {sigma} for {sigma} < 10 but increase comparatively slowly for larger {sigma} values.

  18. Full-Scale Prestress Loss Monitoring of Damaged RC Structures Using Distributed Optical Fiber Sensing Technology

    PubMed Central

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams. PMID:22778590

  19. Full-scale prestress loss monitoring of damaged RC structures using distributed optical fiber sensing technology.

    PubMed

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams.

  20. A heuristic nonlinear constructive method for electric power distribution system reconfiguration

    NASA Astrophysics Data System (ADS)

    McDermott, Thomas E.

    1998-12-01

    The electric power distribution system usually operates in a radial configuration, with tie switches between circuits to provide alternate feeds. The losses would be minimized if all switches were closed, but this is not done because it complicates the system's protection against overcurrents. Whenever a component fails, some of the switches must be operated to restore power to as many customers as possible. As loads vary with time, switch operations may reduce losses in the system. Both of these are applications for reconfiguration. The problem is combinatorial, which precludes algorithms that guarantee a global optimum. Most existing reconfiguration algorithms fall into two categories. In the first, branch exchange, the system operates in a feasible radial configuration and the algorithm opens and closes candidate switches in pairs. In the second, loop cutting, the system is completely meshed and the algorithm opens candidate switches to reach a feasible radial configuration. Reconfiguration algorithms based on linearized transshipment, neural networks, heuristics, genetic algorithms, and simulated annealing have also been reported, but not widely used. These existing reconfiguration algorithms work with a simplified model of the power system, and they handle voltage and current constraints approximately, if at all. The algorithm described here is a constructive method, using a full nonlinear power system model that accurately handles constraints. The system starts with all switches open and all failed components isolated. An optional network power flow provides a lower bound on the losses. Then the algorithm closes one switch at a time to minimize the increase in a merit figure, which is the real loss divided by the apparent load served. The merit figure increases with each switch closing. This principle, called discrete ascent optimal programming (DAOP), has been applied to other power system problems, including economic dispatch and phase balancing. For

  1. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Unknown

    2002-03-01

    This report summarizes the work performed by Honeywell during the July 2001 to September 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. An internal program kickoff was held at Honeywell in Torrance, CA. The program structure was outlined and the overall technical approach for the program was presented to the team members. Detail program schedules were developed and detailed objectives were defined. Initial work has begun on the system design and pressurized SOFC operation.

  2. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Kurt Montgomery; Nguyen Minh

    2003-08-01

    This report summarizes the work performed by Honeywell during the October 2001 to December 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The conceptual and demonstration system designs were proposed and analyzed, and these systems have been modeled in Aspen Plus. Work has also started on the assembly of dynamic component models and the development of the top-level controls requirements for the system. SOFC stacks have been fabricated and performance mapping initiated.

  3. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh

    2002-03-31

    This report summarizes the work performed by Honeywell during the January 2002 to March 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. For this reporting period the following activities have been carried out: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} System-level performance model was created {lg_bullet} Dynamic control models are being developed {lg_bullet} Mechanical properties of candidate heat exchanger materials were investigated {lg_bullet} SOFC performance mapping as a function of flow rate and pressure was completed

  4. Leadership in Mammalian Societies: Emergence, Distribution, Power, and Payoff.

    PubMed

    Smith, Jennifer E; Gavrilets, Sergey; Mulder, Monique Borgerhoff; Hooper, Paul L; El Mouden, Claire; Nettle, Daniel; Hauert, Christoph; Hill, Kim; Perry, Susan; Pusey, Anne E; van Vugt, Mark; Smith, Eric Alden

    2016-01-01

    Leadership is an active area of research in both the biological and social sciences. This review provides a transdisciplinary synthesis of biological and social-science views of leadership from an evolutionary perspective, and examines patterns of leadership in a set of small-scale human and non-human mammalian societies. We review empirical and theoretical work on leadership in four domains: movement, food acquisition, within-group conflict mediation, and between-group interactions. We categorize patterns of variation in leadership in five dimensions: distribution (across individuals), emergence (achieved versus inherited), power, relative payoff to leadership, and generality (across domains). We find that human leadership exhibits commonalities with and differences from the broader mammalian pattern, raising interesting theoretical and empirical issues.

  5. A distributed power market for the Smart Grid

    NASA Astrophysics Data System (ADS)

    McCulloch, Ryan James

    To address the challenges of resource allocation in the Smart Electrical Grid a new power market is proposed. A distributed and autonomous contract net based market system in which participants, represented by the agents, engage in two distinct yet interconnected markets in order to determine resource allocation. Key to this proposed design is the 2 market structure which separates negotiations between consumers and reliable generation from negotiations between consumers and intermittent energy resources. The first or primary market operates as a first price sealed bid reverse auction while the second or secondary market utilizes a uniform price auction. In order to evaluate this new market a simulator is developed and the market is modeled and tested within it. The results of these tests indicate that the proposed design is an effective method of allocating electrical grid resources amongst consumers, generators, and intermittent energy resources with some feasibility and scalability limitations.

  6. Impact of Increasing Distributed Wind Power and Wind Turbine Siting on Rural Distribution Feeder Voltage Profiles: Preprint

    SciTech Connect

    Allen, A.; Zhang, Y. C.; Hodge, B. M.

    2013-09-01

    Many favorable wind energy resources in North America are located in remote locations without direct access to the transmission grid. Building transmission lines to connect remotely-located wind power plants to large load centers has become a barrier to increasing wind power penetration in North America. By connecting utility-sized megawatt-scale wind turbines to the distribution system, wind power supplied to consumers could be increased greatly. However, the impact of including megawatt-scale wind turbines on distribution feeders needs to be studied. The work presented here examined the impact that siting and power output of megawatt-scale wind turbines have on distribution feeder voltage. This is the start of work to present a general guide to megawatt-scale wind turbine impact on the distribution feeder and finding the amount of wind power that can be added without adversely impacting the distribution feeder operation, reliability, and power quality.

  7. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2011-03-15

    The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  8. Estimating spatial distribution of soil loss over Seyhan River Basin in Turkey

    NASA Astrophysics Data System (ADS)

    İrvem, Ahmet; Topaloğlu, Fatih; Uygur, Veli

    2007-03-01

    SummaryThe purpose of this study was to investigate the spatial distribution of annual soil loss in Seyhan River Basin using USLE model. A geographic information system (GIS) was used to generate maps of the USLE factors which are rainfall erosivity ( R), soil erodibility ( K), slope length and steepness ( LS), cover ( C) and conservation practices ( P) factors. By integrating these maps in GIS, spatial distribution of soil loss over the Seyhan River Basin was obtained. Annual average soil loss for the Seyhan River Basin was 16.38 t ha -1 y -1. Annual soil loss more than 200 t ha -1 y -1 in pixel level was in the southern region, while the northern region showed the lower annual values. These results are verified by comparing sediment yield measurements in the basin. An area about 198.25 km 2 (0.96%) experiences extremely severe erosion risk, which needs suitable conservation measures to be adopted on a priority basis. The spatial distribution of erosion risk classes estimated 61.03% very low, 8.76% low, 23.52% moderate, 4.03% severe and 1.70% very severe. Thus, the USLE model was used in a GIS environment to identify regions susceptible to water erosion and needing immediate soil conservation planning and application in the Seyhan River Basin in Turkey.

  9. C -parameter distribution at N3LL' including power corrections

    NASA Astrophysics Data System (ADS)

    Hoang, André H.; Kolodrubetz, Daniel W.; Mateu, Vicent; Stewart, Iain W.

    2015-05-01

    We compute the e+e- C -parameter distribution using the soft-collinear effective theory with a resummation to next-to-next-to-next-to-leading-log prime accuracy of the most singular partonic terms. This includes the known fixed-order QCD results up to O (αs3), a numerical determination of the two-loop nonlogarithmic term of the soft function, and all logarithmic terms in the jet and soft functions up to three loops. Our result holds for C in the peak, tail, and far tail regions. Additionally, we treat hadronization effects using a field theoretic nonperturbative soft function, with moments Ωn. To eliminate an O (ΛQCD) renormalon ambiguity in the soft function, we switch from the MS ¯ to a short distance "Rgap" scheme to define the leading power correction parameter Ω1. We show how to simultaneously account for running effects in Ω1 due to renormalon subtractions and hadron-mass effects, enabling power correction universality between C -parameter and thrust to be tested in our setup. We discuss in detail the impact of resummation and renormalon subtractions on the convergence. In the relevant fit region for αs(mZ) and Ω1, the perturbative uncertainty in our cross section is ≃ 2.5 % at Q =mZ.

  10. Power Law Distributions of Patents as Indicators of Innovation

    PubMed Central

    O’Neale, Dion R. J.; Hendy, Shaun C.

    2012-01-01

    The total number of patents produced by a country (or the number of patents produced per capita) is often used as an indicator for innovation. Here we present evidence that the distribution of patents amongst applicants within many countries is well-described by power laws with exponents that vary between 1.66 (Japan) and 2.37 (Poland). We suggest that this exponent is a useful new metric for studying innovation. Using simulations based on simple preferential attachment-type rules that generate power laws, we find we can explain some of the variation in exponents between countries, with countries that have larger numbers of patents per applicant generally exhibiting smaller exponents in both the simulated and actual data. Similarly we find that the exponents for most countries are inversely correlated with other indicators of innovation, such as research and development intensity or the ubiquity of export baskets. This suggests that in more advanced economies, which tend to have smaller values of the exponent, a greater proportion of the total number of patents are filed by large companies than in less advanced countries. PMID:23227144

  11. C -parameter distribution at N 3 LL ' including power corrections

    DOE PAGES

    Hoang, André H.; Kolodrubetz, Daniel W.; Mateu, Vicent; ...

    2015-05-15

    We compute the e⁺e⁻ C-parameter distribution using the soft-collinear effective theory with a resummation to next-to-next-to-next-to-leading-log prime accuracy of the most singular partonic terms. This includes the known fixed-order QCD results up to O(α3s), a numerical determination of the two-loop nonlogarithmic term of the soft function, and all logarithmic terms in the jet and soft functions up to three loops. Our result holds for C in the peak, tail, and far tail regions. Additionally, we treat hadronization effects using a field theoretic nonperturbative soft function, with moments Ωn. To eliminate an O(ΛQCD) renormalon ambiguity in the soft function, we switchmore » from the MS¯ to a short distance “Rgap” scheme to define the leading power correction parameter Ω1. We show how to simultaneously account for running effects in Ω1 due to renormalon subtractions and hadron-mass effects, enabling power correction universality between C-parameter and thrust to be tested in our setup. We discuss in detail the impact of resummation and renormalon subtractions on the convergence. In the relevant fit region for αs(mZ) and Ω1, the perturbative uncertainty in our cross section is ≅ 2.5% at Q=mZ.« less

  12. Fuel cell power plants in a distributed generator application

    SciTech Connect

    Smith, M.J.

    1996-12-31

    ONSI`s (a subsidiary of International Fuel Cells Corporation) world wide fleet of 200-kW PC25{trademark} phosphoric acid fuel cell power plants which began operation early in 1992 has shown excellent performance and reliability in over 1 million hours of operation. This experience has verified the clean, quiet, reliable operation of the PC25 and confirmed its application as a distributed generator. Continuing product development efforts have resulted in a one third reduction of weight and volume as well as improved installation and operating characteristics for the PC25 C model. Delivery of this unit began in 1995. International Fuel Cells (IFC) continues its efforts to improve product design and manufacturing processes. This progress has been sustained at a compounded rate of 10 percent per year since the late 1980`s. These improvements will permit further reductions in the initial cost of the power plant and place increased emphasis on market development as the pacing item in achieving business benefits from the PC25 fuel cell. Derivative product opportunities are evolving with maturation of the technologies in a commercial environment. The recent announcement of Praxair, Inc., and IFC introducing a non-cryogenic hydrogen supply system utilizing IFC`s steam reformer is an example. 11 figs.

  13. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Faress Rahman; Nguyen Minh

    2003-07-01

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC during the January 2003 to June 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. This report summarizes the results obtained to date on: System performance analysis and model optimization; Reliability and cost model development; System control including dynamic model development; Heat exchanger material tests and life analysis; Pressurized SOFC evaluation; and Pre-baseline system definition for coal gasification fuel cell system concept.

  14. Power law distributions of patents as indicators of innovation.

    PubMed

    O'Neale, Dion R J; Hendy, Shaun C

    2012-01-01

    The total number of patents produced by a country (or the number of patents produced per capita) is often used as an indicator for innovation. Here we present evidence that the distribution of patents amongst applicants within many countries is well-described by power laws with exponents that vary between 1.66 (Japan) and 2.37 (Poland). We suggest that this exponent is a useful new metric for studying innovation. Using simulations based on simple preferential attachment-type rules that generate power laws, we find we can explain some of the variation in exponents between countries, with countries that have larger numbers of patents per applicant generally exhibiting smaller exponents in both the simulated and actual data. Similarly we find that the exponents for most countries are inversely correlated with other indicators of innovation, such as research and development intensity or the ubiquity of export baskets. This suggests that in more advanced economies, which tend to have smaller values of the exponent, a greater proportion of the total number of patents are filed by large companies than in less advanced countries.

  15. Induced magnetization and power loss for a periodically driven system of ferromagnetic nanoparticles with randomly oriented easy axes

    NASA Astrophysics Data System (ADS)

    Denisov, S. I.; Lyutyy, T. V.; Pedchenko, B. O.; Hryshko, O. M.

    2016-07-01

    We study the effect of an elliptically polarized magnetic field on a system of noninteracting, single-domain ferromagnetic nanoparticles characterized by a uniform distribution of easy axis directions. Our main goal is to determine the average magnetization of this system and the power loss in it. In order to calculate these quantities analytically, we develop a general perturbation theory for the Landau-Lifshitz-Gilbert (LLG) equation and find its steady-state solution for small magnetic field amplitudes. On this basis, we derive the second-order expressions for the average magnetization and power loss, investigate their dependence on the magnetic field frequency, and analyze the role of subharmonic resonances resulting from the nonlinear nature of the LLG equation. For arbitrary amplitudes, the frequency dependence of these quantities is obtained from the numerical solution of this equation. The impact of transitions between different regimes of regular and chaotic dynamics of magnetization, which can be induced in nanoparticles by changing the magnetic field frequency, is examined in detail.

  16. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    SciTech Connect

    Dailey, James; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-11-12

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA.

  17. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    DOE PAGES

    Dailey, James; Agarwal, Anjali; Toliver, Paul; ...

    2015-11-12

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA.

  18. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    PubMed Central

    Dailey, James M.; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-01-01

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA. PMID:26559465

  19. Improved designs for p-i-n OLEDs towards the minimal power loss of devices

    NASA Astrophysics Data System (ADS)

    Qin, Dashan

    2014-05-01

    Currently, the low yield, high power loss, and poor stability of organic light emitting diodes (OLEDs) panels are remaining as the obstacles to the fast growth of the OLED industry, especially for the lighting application. The p-i-n OLEDs have been widely recognized as the promising method to circumvent these bottleneck factors, due to the unique merit of the electrical doping to enable low power loss. In p-i-n OLEDs, the frequently used n-doped electron transport layers (n-ETL1) such as n-BCP, n-Alq3 possess markedly lower conductivities but better capabilities of injecting electrons into ETL such as BCP, Alq3, as compared to another class of n-doped ETLs (n-ETL2), e.g., n-NTCDA, n-PTCDA, n-C60. Thus, in order to minimize the electron loss, we provide the structure of uniting two n-doped layers, cathode/ n-ETL2/ n-ETL1/ ETL. In p-i-n OLEDs, the hole current injected from the single p-doped hole transport layer (p-HTL) into the neat HTL must be limited, because the higher conductivity p-HTL has the higher lying highest occupied molecular orbital (HOMO) level, leading to a larger hole transport energy barrier (φB) at the interface with the neat HTL. Therefore, in order to minimize the hole loss, we suggest the structure of uniting two p-HTLs, anode/ p-HTL2/ p-HTL1/ HTL. The p-HTL2 possesses high-lying HOMO level and thereby high conductivity, decreasing the ohmic loss in the hole conduction; the p-HTL1 features a low-lying HOMO level, reducing the φB.

  20. A reformer to generate hydrogen for distributed power applications

    SciTech Connect

    Cole, J.A.; Kumar, R.V.; West, J.; Lyon, R.K.

    1998-07-01

    The generation of power using fuel cells is a promising technology for distributed electric power generation applications. Steam reforming of fossil fuels remains the most thermodynamically efficient means for production of hydrogen. Unfortunately, current steam reforming technology achieves high efficiencies only at very large scales, and remains impractical at the small production rates needed for small- to medium-size distributed power applications. A novel reformer process, called unmixed reforming, or UMR, has been developed for the conversion of hydrocarbon fuels (natural gas, diesel, gasoline) to hydrogen. The reformer promises high thermodynamic efficiency as heat is generated right on the catalytic bed unlike conventional reforming. The controlled combustion on the reforming catalyst using a patented technology called unmixed combustion provides the heat for the endothermic reforming reaction. The reformer generates a high-purity hydrogen product stream, which can then be used by fuel cells with minimal processing. The unmixed reformer is a packed-bed consisting of finely divided nickel supported on a ceramic matrix mixed with a calcium oxide bearing matrix such as dolomite. UMR consists of three process steps. During the first step air is passed over the packed-bed reactor to oxidize the nickel. The heat released during the oxidation reaction raises the temperature of the bed and decomposes the dolomite releasing carbon dioxide into a vent gas stream. In the subsequent step fuel passed over the packed-bed reduces the NiO back to Ni and further increases the temperature. In the final step, fuel and steam react to produce hydrogen through conventional steam reforming chemistry. The calcium oxide captures some of the carbon dioxide formed during the reforming reaction and thus shifts the reforming reactions to higher conversions, hence improving the purity of the hydrogen product stream. Although product hydrogen concentrations may be 75--85%, the CO content

  1. Aging Management Guideline for commercial nuclear power plants: Power and distribution transformers

    SciTech Connect

    Toman, G.; Gazdzinski, R.

    1994-05-01

    This Aging Management Guideline (AMG) provides recommended methods for effective detection and mitigation of age-related degradation mechanisms in power and distribution transformers important to license renewal in commercial nuclear power plants. The intent of this AMG to assist plant maintenance and operations personnel in maximizing the safe, useful life of these components. It also supports the documentation of effective aging management programs required under the License Renewal Rule 10 CFR Part 54. This AMG is presented in a manner which allows personnel responsible for performance analysis and maintenance to compare their plant-specific aging mechanisms (expected or already experienced) and aging management program activities to the more generic results and recommendations presented herein.

  2. Winter respiratory C losses provide explanatory power for net ecosystem productivity

    NASA Astrophysics Data System (ADS)

    Haeni, M.; Zweifel, R.; Eugster, W.; Gessler, A.; Zielis, S.; Bernhofer, C.; Carrara, A.; Grünwald, T.; Havránková, K.; Heinesch, B.; Herbst, M.; Ibrom, A.; Knohl, A.; Lagergren, F.; Law, B. E.; Marek, M.; Matteucci, G.; McCaughey, J. H.; Minerbi, S.; Montagnani, L.; Moors, E.; Olejnik, J.; Pavelka, M.; Pilegaard, K.; Pita, G.; Rodrigues, A.; Sanz Sánchez, M. J.; Schelhaas, M.-J.; Urbaniak, M.; Valentini, R.; Varlagin, A.; Vesala, T.; Vincke, C.; Wu, J.; Buchmann, N.

    2017-01-01

    Accurate predictions of net ecosystem productivity (NEPc) of forest ecosystems are essential for climate change decisions and requirements in the context of national forest growth and greenhouse gas inventories. However, drivers and underlying mechanisms determining NEPc (e.g., climate and nutrients) are not entirely understood yet, particularly when considering the influence of past periods. Here we explored the explanatory power of the compensation day (cDOY)—defined as the day of year when winter net carbon losses are compensated by spring assimilation—for NEPc in 26 forests in Europe, North America, and Australia, using different NEPc integration methods. We found cDOY to be a particularly powerful predictor for NEPc of temperate evergreen needleleaf forests (R2 = 0.58) and deciduous broadleaf forests (R2 = 0.68). In general, the latest cDOY correlated with the lowest NEPc. The explanatory power of cDOY depended on the integration method for NEPc, forest type, and whether the site had a distinct winter net respiratory carbon loss or not. The integration methods starting in autumn led to better predictions of NEPc from cDOY then the classical calendar method starting 1 January. Limited explanatory power of cDOY for NEPc was found for warmer sites with no distinct winter respiratory loss period. Our findings highlight the importance of the influence of winter processes and the delayed responses of previous seasons' climatic conditions on current year's NEPc. Such carry-over effects may contain information from climatic conditions, carbon storage levels, and hydraulic traits of several years back in time.

  3. Shortening-induced torque depression in old men: implications for age-related power loss.

    PubMed

    Power, Geoffrey A; Makrakos, Demetri P; Stevens, Daniel E; Herzog, Walter; Rice, Charles L; Vandervoort, Anthony A

    2014-09-01

    Following active muscle shortening, the steady-state isometric torque at the final muscle length is lower than the steady-state torque obtained for a purely isometric contraction at that same final muscle length. This well-documented property of skeletal muscle is termed shortening-induced torque depression (TD). Despite many investigations into the mechanisms of weakness and power loss in old age, the influence of muscle shortening on the history dependence of isometric torque production remains to be elucidated. Thus, it is unclear whether older adults are disadvantaged for torque and power production following a dynamic shortening contraction. The purpose of this study was to evaluate shortening-induced TD in older adults, and to determine whether shortening-induced TD is related to power loss. Maximal voluntary isometric dorsiflexion contractions (MVC; 10s) in 8 young (25.5±3.7years) and 9 old (76.1±5.4years) men were performed on a HUMAC NORM dynamometer as a reference, and then again following an active shortening of 40° joint excursion (40°PF-0°PF) at angular velocities of 15°/s and 120°/s. Work and instantaneous power were derived during shortening. Shortening-induced TD was calculated and expressed as a percentage by determining the mean torque value over 1s during the isometric steady state of the MVC following shortening, divided by the mean torque value for the same 1s time period during the isometric reference MVC. To assess muscle activation, electromyography (root mean square; EMGRMS) of the tibialis anterior (TA) and soleus (SOL) was calculated at identical time points used in assessing shortening-induced TD, and voluntary activation (VA) was assessed using the interpolated twitch technique. Old were 18% weaker than young for MVC, and ~40% less powerful for 15°/s and 120°/s of shortening. Old produced 37% and 21% less work for 15°/s and 120°/s than young, respectively. Furthermore, old experienced 60% and 70% greater shortening-induced TD

  4. Exponential and power-law mass distributions in brittle fragmentation

    NASA Astrophysics Data System (ADS)

    Åström, J. A.; Linna, R. P.; Timonen, J.; Møller, Peder Friis; Oddershede, Lene

    2004-08-01

    Generic arguments, a minimal numerical model, and fragmentation experiments with gypsum disk are used to investigate the fragment-size distribution that results from dynamic brittle fragmentation. Fragmentation is initiated by random nucleation of cracks due to material inhomogeneities, and its dynamics are pictured as a process of propagating cracks that are unstable against side-branch formation. The initial cracks and side branches both merge mutually to form fragments. The side branches have a finite penetration depth as a result of inherent damping. Generic arguments imply that close to the minimum strain (or impact energy) required for fragmentation, the number of fragments of size s scales as s-(2D-1)/Df1(-(2/λ)Ds)+f2(-s0-1(λ+s1/D)D) , where D is the Euclidean dimension of the space, λ is the penetration depth, and f1 and f2 can be approximated by exponential functions. Simulation results and experiments can both be described by this theoretical fragment-size distribution. The typical largest fragment size s0 was found to diverge at the minimum strain required for fragmentation as it is inversely related to the density of initially formed cracks. Our results also indicate that scaling of s0 close to this divergence depends on, e.g., loading conditions, and thus is not universal. At the same time, the density of fragment surface vanishes as L-1 , L being the linear dimension of the brittle solid. The results obtained provide an explanation as to why the fragment-size distributions found in nature can have two components, an exponential as well as a power-law component, with varying relative weights.

  5. Power law olivine crystal size distributions in lithospheric mantle xenoliths

    NASA Astrophysics Data System (ADS)

    Armienti, P.; Tarquini, S.

    2002-12-01

    Olivine crystal size distributions (CSDs) have been measured in three suites of spinel- and garnet-bearing harzburgites and lherzolites found as xenoliths in alkaline basalts from Canary Islands, Africa; Victoria Land, Antarctica; and Pali Aike, South America. The xenoliths derive from lithospheric mantle, from depths ranging from 80 to 20 km. Their textures vary from coarse to porphyroclastic and mosaic-porphyroclastic up to cataclastic. Data have been collected by processing digital images acquired optically from standard petrographic thin sections. The acquisition method is based on a high-resolution colour scanner that allows image capturing of a whole thin section. Image processing was performed using the VISILOG 5.2 package, resolving crystals larger than about 150 μm and applying stereological corrections based on the Schwartz-Saltykov algorithm. Taking account of truncation effects due to resolution limits and thin section size, all samples show scale invariance of crystal size distributions over almost three orders of magnitude (0.2-25 mm). Power law relations show fractal dimensions varying between 2.4 and 3.8, a range of values observed for distributions of fragment sizes in a variety of other geological contexts. A fragmentation model can reproduce the fractal dimensions around 2.6, which correspond to well-equilibrated granoblastic textures. Fractal dimensions >3 are typical of porphyroclastic and cataclastic samples. Slight bends in some linear arrays suggest selective tectonic crushing of crystals with size larger than 1 mm. The scale invariance shown by lithospheric mantle xenoliths in a variety of tectonic settings forms distant geographic regions, which indicate that this is a common characteristic of the upper mantle and should be taken into account in rheological models and evaluation of metasomatic models.

  6. The impact of distributed generation on the Thailand's electric power system

    NASA Astrophysics Data System (ADS)

    Fuangfoo, Pradit

    Typically, subtransmission and distribution systems are a radial configuration and have only one source from a main grid. The subtransmission and distribution systems are usually not designed to operate with the Distributed Generation (DG) connecting to the systems. In recent years, the installation capacity of DG has increased significantly in the Electrical Power System (EPS), particularly in the subtransmission and distribution systems due to the economical and technical benefits associated with DG such as higher efficiencies, reduced system losses, and enhanced system reliability. If the penetration level of DG continues to increase while the EPS remain unchanged, technical conflicts may develop in the future. In this dissertation, the impact study focuses on the Thailand's EPS. The research performs systematic approach to evaluate the impact of DG on the whole Thailand's ESP and on the local system (subtransmission and distribution systems). This dissertation investigates the effect of DG on both steady-stead and dynamic performance of the whole system. The influence of penetration level together with types and operation modes of DGs are also included. The steady-state study analyzes the effect of DG on voltage profile, system losses, and transmission line usages during normal and abnormal condition, whereas the dynamic impact concentrates on the effect of DG on dynamic stability and small signal stability. The investigated results can be drawn into the policy to determine the maximum penetration level of DG spread out the whole system to avoid the adverse effect from DG. Similarly, the impact study of DG on local system (subtransmission and distribution system) also includes the influence of DG on steady-state and dynamic performance of the system. The steady-state impact of DG on local system focuses on voltage profile, system losses, protection coordination, harmonics, and system reliability. For dynamic impact of DG on local system, the main concern is

  7. Validating MCNP for LEU Fuel Design via Power Distribution Comparisons

    SciTech Connect

    Primm, Trent; Maldonado, G Ivan; Chandler, David

    2008-11-01

    The mission of the Reduced Enrichment for Research and Test Reactors (RERTR) Program is to minimize and, to the extent possible, eliminate the use of highly enriched uranium (HEU) in civilian nuclear applications by working to convert research and test reactors, as well as radioisotope production processes, to low enriched uranium (LEU) fuel and targets. Oak Ridge National Lab (ORNL) is reviewing the design bases and key operating criteria including fuel operating parameters, enrichment-related safety analyses, fuel performance, and fuel fabrication in regard to converting the fuel of the High Flux Isotope Reactor (HFIR) from HEU to LEU. The purpose of this study is to validate Monte Carlo methods currently in use for conversion analyses. The methods have been validated for the prediction of flux values in the reactor target, reflector, and beam tubes, but this study focuses on the prediction of the power density profile in the core. A current 3-D Monte Carlo N-Particle (MCNP) model was modified to replicate the HFIR Critical Experiment 3 (HFIRCE-3) core of 1965. In this experiment, the power profile was determined by counting the gamma activity at selected locations in the core. Foils (chunks of fuel meat and clad) were punched out of the fuel elements in HFIRCE-3 following irradiation and experimental relative power densities were obtained by measuring the activity of these foils and comparing each foil s activity to the activity of a normalizing foil. The current work consisted of calculating corresponding activities by inserting volume tallies into the modified MCNP model to represent the punchings. The average fission density was calculated for each foil location and then normalized to the normalizing foil. Power distributions were obtained for the clean core (no poison in moderator and symmetrical rod position at 17.5 inches) and fully poisoned-moderator (1.35 g B/liter in moderator and rods fully withdrawn) conditions. The observed deviations between the

  8. Use of Transition Modeling to Enable the Computation of Losses for Variable-Speed Power Turbine

    NASA Technical Reports Server (NTRS)

    Ameri, Ali A.

    2012-01-01

    To investigate the penalties associated with using a variable speed power turbine (VSPT) in a rotorcraft capable of vertical takeoff and landing, various analysis tools are required. Such analysis tools must be able to model the flow accurately within the operating envelope of VSPT. For power turbines low Reynolds numbers and a wide range of the incidence angles, positive and negative, due to the variation in the shaft speed at relatively fixed corrected flows, characterize this envelope. The flow in the turbine passage is expected to be transitional and separated at high incidence. The turbulence model of Walters and Leylek was implemented in the NASA Glenn-HT code to enable a more accurate analysis of such flows. Two-dimensional heat transfer predictions of flat plate flow and two-dimensional and three-dimensional heat transfer predictions on a turbine blade were performed and reported herein. Heat transfer computations were performed because it is a good marker for transition. The final goal is to be able to compute the aerodynamic losses. Armed with the new transition model, total pressure losses for three-dimensional flow of an Energy Efficient Engine (E3) tip section cascade for a range of incidence angles were computed in anticipation of the experimental data. The results obtained form a loss bucket for the chosen blade.

  9. Energy Loss, Velocity Distribution, and Temperature Distribution for a Baffled Cylinder Model, Special Report

    NASA Technical Reports Server (NTRS)

    Brevoort, Maurice J.

    1937-01-01

    In the design of a cowling a certain pressure drop across the cylinders of a radial air-cooled engine is made available. Baffles are designed to make use of this available pressure drop for cooling. The problem of cooling an air-cooled engine cylinder has been treated, for the most part, from considerations of a large heat-transfer coefficient. The knowledge of the precise cylinder characteristics that give a maximum heat-transfer coefficient should be the first consideration. The next problem is to distribute this ability to cool so that the cylinder cools uniformly. This report takes up the problem of the design of a baffle for a model cylinder. A study has been made of the important principles involved in the operation of a baffle for an engine cylinder and shows that the cooling can be improved 20% by using a correctly designed baffle. Such a gain is as effective in cooling the cylinder with the improved baffle as a 65% increase in pressure drop across the standard baffle and fin tips.

  10. Role of PCP referral and weight loss in the Hopkins POWER trial.

    PubMed

    Tseng, Eva; Wang, Nae-Yuh; Clark, Jeanne M; Appel, Lawrence J; Bennett, Wendy L

    2015-01-01

    Primary care providers (PCPs) play an important role in identifying and counseling obese patients to lose weight, but it is unknown whether PCP referral of patients into a weight loss intervention is associated with greater weight loss. The objectives are to determine if PCP referral is associated with greater 1) weight loss, 2) end of study patient-provider relationship quality, and 3) satisfaction and participation rates in the intervention. 415 obese patients enrolled in the Hopkins POWER trial from six primary care practices in the Baltimore area. We conducted a secondary analysis of results from the trial using longitudinal mixed-effects model and generalized linear model, adjusting for clinic, sex, age, and race. The primary outcome was absolute weight change from baseline to 24 months. Secondary outcomes were patient-provider relationship quality and satisfaction and participation rates in the intervention. Participants in both PCP and non-PCP referral groups lost a similar amount of weight from baseline to 24 months. PCP referral was not significantly associated with percentage of completed coach contacts, web logins, and satisfaction with trial, but was associated with higher end of study patient-provider relationship quality (p = 0.007). Our study represents the first of its kind to examine the role of PCP referral of patients into a weight loss trial. While we did not find evidence that PCP referral is associated with increased weight loss, further research is needed to determine how PCPs can use their relationship with patients to promote weight loss and enhance intervention effects.

  11. Development of a current collection loss management system for SDI homopolar power supplies

    SciTech Connect

    Brown, D.W.

    1989-01-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operate continuously at 2 kA/cm{sup 2}, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To data, no system has achieved these conditions simultaneously. This is the annual report covering the second year period of performance on DOE contract DE-AC03-86SF16518. Major areas covered include design, construction and operation of a cryogenically cooled brush test rig, design and construction of a high speed brush test rig, optimization study for homopolar machines, loss analysis of the current collection system, and an application study which defines the air-core homopolar construction necessary to achieve the goal of 80--90 kW/kg generator power density. 17 figs., 2 tabs.

  12. Development of a current collection loss management system for SDI homopolar power supplies

    SciTech Connect

    Hannan, W.F. III.

    1987-01-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operated continuously at 2 kA/cm{sup 2}, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To data, no system has achieved these conditions simultaneously. This is the annual report covering the first year period of performance on DOE contract DE-AC03-86SF16518. Major areas covered include design and construction of a cryogenically-cooled brush test rig, design of a high speed brush test rig, loss analysis of the current collection system, and an application study which defines the air core homopolar construction necessary to achieve the goal of 80--90 kW/kg generator power density. 15 figs.

  13. Development of a current collection loss management system for SDI homopolar power supplies

    NASA Astrophysics Data System (ADS)

    Brown, D. W.

    1991-04-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operate continuously at 2 kA/sq cm, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To date, no system has achieved these conditions simultaneously. This is the final report covering the three year period of performance on DOE contract AC03-86SF-16518. Major areas covered include design, construction and operation of a cryogenically cooled brush test rig, design and construction of a high speed brush test rig, optimization study for homopolar machines, loss analysis of the current collection system, and an application study which defines the air-core homopolar construction necessary to achieve the goal of 80 kW/kg generator power density.

  14. Impact of high power and angle of incidence on prism corrections for visual field loss

    PubMed Central

    Jung, Jae-Hyun; Peli, Eli

    2014-01-01

    Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice. PMID:24497649

  15. Plasma Efficiency and Losses for pulsed Xe Excimer DBDs at high Power Densities

    NASA Astrophysics Data System (ADS)

    Paravia, Mark; Meisser, Michael; Heering, Wolfgang

    2009-10-01

    The UV water disinfection for example needs efficient lamps with high power densities. Xe2^* dielectric barrier discharges (DBDs) with phosphor coating can be used due to plasma efficiencies up to 60 % at pulsed electrical power densities of 0.04 W/cm^2 [1]. The power density can be increased by pressure or (operation) frequency. However, the plasma efficiency declines with frequency. We present measurements of the radiant flux for pulsed DBDs made of fused silica as function of pressure and frequency. By calculation of optical losses the plasma efficiency is estimated to be 52 % at 0.07 W/cm^2 but decreases to 34 % at 0.8 W/cm^2. The maximum frequency is pressure dependent and limited due to change-over from homogeneous into filamented mode. In comparison we measured the gas gap voltage and internal plasma current of a pulsed planar DBD for general lighting [2]. This comparison makes it possible to explain the frequency dependence of plasma efficiency and radiant flux. Due to the high frequency the remaining charge density is increased and the discharge becomes a glow discharge. For that reason the typical peak current during ignition drops and explains the declined efficiency by glow phase losses. [4pt] [1] Beleznai, S., et al., JPhysD, 41 (2008) [0pt] [2] Paravia, M., et al., GEC, Dallas, 2008

  16. Impact of high power and angle of incidence on prism corrections for visual field loss

    NASA Astrophysics Data System (ADS)

    Jung, Jae-Hyun; Peli, Eli

    2014-06-01

    Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high-power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice.

  17. Prediction of sound transmission loss through multilayered panels by using Gaussian distribution of directional incident energy

    PubMed

    Kang; Ih; Kim; Kim

    2000-03-01

    In this study, a new prediction method is suggested for sound transmission loss (STL) of multilayered panels of infinite extent. Conventional methods such as random or field incidence approach often given significant discrepancies in predicting STL of multilayered panels when compared with the experiments. In this paper, appropriate directional distributions of incident energy to predict the STL of multilayered panels are proposed. In order to find a weighting function to represent the directional distribution of incident energy on the wall in a reverberation chamber, numerical simulations by using a ray-tracing technique are carried out. Simulation results reveal that the directional distribution can be approximately expressed by the Gaussian distribution function in terms of the angle of incidence. The Gaussian function is applied to predict the STL of various multilayered panel configurations as well as single panels. The compared results between the measurement and the prediction show good agreements, which validate the proposed Gaussian function approach.

  18. Theoretical concept and FEM simulations of improved shielding for round horizontal yokes for rotational power loss measurement

    NASA Astrophysics Data System (ADS)

    Zurek, Stan

    2017-08-01

    The paper introduces a theoretical concept of a shielding for horizontal yokes for measurements of rotational power loss and other rotational and two-dimensional properties. Apart from horizontal parts, the shielding relies on vertical pieces distributed uniformly around the sample circumference, symmetrically on both sides. The simulations in 2D and 3D FEM show significant improvement in reduction of H perpendicular to the sample surface (Hz). The gradient of the tangential H is reduced so that the extrapolation of values towards the surface might be no longer required. There is also an added benefit that the required magnetomotive force is significantly lower (20-70%) for achieving the same B in the sample, as compared to the previously used simple horizontal shields.

  19. Creating markets for combined heat and power and clean distributed generation in New York State.

    PubMed

    Bourgeois, Thomas G; Hedman, Bruce; Zalcman, Fred

    2003-01-01

    Combined heat and power (CHP) is the simultaneous production of electrical or mechanical power and thermal energy from in a single process. Because thermal output from the generation of electricity is captured and utilized onsite, CHP systems can achieve efficiencies from 60% to as high as 90%. In contrast generation of electric power at sites remote from the loads served often results in efficiencies of 33% or less due to losses in generation and transmission and distribution of the power to ultimate end users. A well designed CHP system is the essence of energy efficiency. It may also provide significant environmental benefits. However, the full promise of CHP for improving the efficiency and productivity of businesses and the quality of the environment is unlikely to be realized given the current market structure and regulatory environment in which CHP projects are forced to compete. This paper examines the market structure and regulatory obstacles that hinder the development of more robust markets for CHP in New York State.

  20. Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review

    SciTech Connect

    Wu, Shuang-Ying; Xiao, Lan; Li, You-Rong; Cao, Yiding

    2010-08-15

    The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. The studies related to those applications may provide valuable information for the solar receiver design, which may otherwise be ignored by a solar system designer. Finally, future development directions and the issues that need to be further investigated are also suggested. It is believed that this comprehensive review will be beneficial to the design, simulation, performance assessment and applications of the solar parabolic dish cavity receivers. (author)

  1. Magnetic particle hyperthermia: power losses under circularly polarized field in anisotropic nanoparticles.

    PubMed

    Nándori, I; Rácz, J

    2012-12-01

    The deterministic Landau-Lifshitz-Gilbert equation has been used to investigate the nonlinear dynamics of magnetization and the specific power loss in magnetic nanoparticles with uniaxial anisotropy driven by a rotating magnetic field, generalizing the results obtained for the isotropic case found by P. F. de Châtel, I. Nándori, J. Hakl, S. Mészáros, and K. Vad [J. Phys. Condens. Matter 21, 124202 (2009)]. As opposed to many applications of magnetization reversal in single-domain ferromagnetic particles, where losses must be minimized, in this paper, we study the mechanisms of dissipation used in cancer therapy by hyperthermia, which requires the enhancement of energy losses. We show that for circularly polarized field, the energy loss per cycle is decreased by the anisotropy compared to the isotropic case when only dynamical effects are taken into account. Thus, in this case, in the low-frequency limit, a better heating efficiency can be achieved for isotropic nanoparticles. The possible role of thermal fluctuations is also discussed. Results obtained are compared to experimental data.

  2. Energy loss distributions of relativistic protons axially channeled in a bent silicon crystal

    NASA Astrophysics Data System (ADS)

    Stojanov, Nace; Petrović, Srdjan; Nešković, Nebojša

    2013-05-01

    A detailed study of the energy loss distributions of the relativistic protons axially channeled in the bent < 100 > Si crystals is presented in this work. The bending angle was varied from 0 to 20 μrad, while the crystal thickness was equal to 1 mm. The proton energy was chosen to be 7 TeV in accordance with the Large Hadron Collider (LHC) project, at the European Organization for Nuclear Research (CERN), in Geneva, Switzerland. The energy loss distributions of the channeled protons were generated using the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. An accurate energy loss model was used, which takes into account the trajectory dependence of the energy loss of protons during their motion through the crystal channels. Further, the dispersion of the proton's scattering angle caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The calculated dependence of the number of dechanneled protons on the bending angle was excellently fitted by the Gompertz type dechanneling function.

  3. [Vitamin C loss in vegetables during storage, preparation and distribution in restaurants].

    PubMed

    Moraes, Flávia Aparecida; Cota, Alessandra Miranda; Campos, Flávia Milagres; Pinheiro-Sant'Ana, Helena Maria

    2010-01-01

    The main objective of this study was to evaluate vitamin c loss following vegetable manipulation stages, reception, storage, preparation, and distribution, in commercial and institutional restaurants. Seven vegetables were used: lettuce, carrots, chicory, collard greens, cauliflower, cabbage and tomatoes. Vitamin c analysis was made by high-performance liquid chromatography (hplc). After all manipulation stages, cumulative vitamin c loss was high in vegetables prepared in institutional restaurants and commercial restaurants corresponding to 44.38%-67.03% and 32.90%-71.32%, respectively. In both restaurants, storage accounted for the most expressive loss of vitamin c in the majority of the vegetables. The adoption of measurements to control vitamin c loss in vegetables is suggested, such as purchase and reception according to demand, storage at refrigerated temperatures, monitoring of hygiene and sanitation times, slicing near serving time, cooking preferably steamed, by pressure or stewed, monitoring of cooking time and temperature, and control of the exposure time between preparation and distribution. The results obtained for vitamin c content contribute to the nutritional characterization of vegetables, since studies related to this area are scarce in brazil and in the world.

  4. Simulation of the ohmic loss in photovoltaic laser-power converters for wavelengths of 809 and 1064 nm

    SciTech Connect

    Emelyanov, V. M. Mintairov, S. A.; Sorokina, S. V.; Khvostikov, V. P.; Shvarts, M. Z.

    2016-01-15

    The method of mathematical simulation is used to examine the influence exerted by the characteristics of the epitaxial structure and contact grid of photovoltaic laser-power converters on their ohmic loss. The maximum attainable photoconverter efficiency at a Gaussian distribution of the laser-beam intensity on the surface of a photovoltaic converter and at dark-current densities of p–n junctions typical of structures grown by the metal-organic vapor-phase epitaxy (MOVPE) technique are determined. An approach to finding the optimal parameters of GaAs and In{sub 0.24}Ga{sub 0.76}As/GaAs photovoltaic converters in relation to the optical power being converted is suggested, and the structural parameters for incident-power values of 5, 20, and 50 W at wavelengths of 809 and 1064 nm are determined. It is found that, at laser-light intensities of up to 5 W, >60% efficiency can be achieved in laser-light conversion at a wavelength of 809 nm and >55% efficiency, at a wavelength of 1064 nm.

  5. Evaluation of Potential Energy Loss Reduction and Savings for U. S. Army Electrical Distribution Systems

    DTIC Science & Technology

    1993-09-01

    CtC 14z 8 4io x 0L F. x L 00 Oi I I L 8 0 CLU 100 Three Phase Substation Secondary Prmary Feeders I• Phase A I I -t L Phase C Common Ti Cto LUIJ...losses. 63 USACERL DISTRIBUTION Chief of Enarmer 4th Infamy Div (MECH) TVADOC US Mslary Aedcmry I(M6 ATTN: CE•IC-lA4-LH 42) ATN: AFZC-FE £1913 ATTN: DEN

  6. Saturation of cyclotron maser instability driven by an electron loss-cone distribution

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Lee, M. C.

    1986-01-01

    The resonance diffusion of electrons in velocity space caused by the excited EM wave fields is considered to be the dominant saturation process of cyclotron maser instability that is driven by an electron loss-cone distribution. An upper bound of the saturation level is derived analytically. Since the resulting saturation level is low, the resonance diffusion is indeed responsible for the saturation of the cyclotron maser instability.

  7. The place of solar power: an economic analysis of concentrated and distributed solar power

    PubMed Central

    2012-01-01

    Background This paper examines the cost and benefits, both financial and environmental, of two leading forms of solar power generation, grid-tied photovoltaic cells and Dish Stirling Systems, using conventional carbon-based fuel as a benchmark. Methods First we define how these solar technologies will be implemented and why. Then we delineate a model city and its characteristics, which will be used to test the two methods of solar-powered electric distribution. Then we set the constraining assumptions for each technology, which serve as parameters for our calculations. Finally, we calculate the present value of the total cost of conventional energy needed to power our model city and use this as a benchmark when analyzing both solar models’ benefits and costs. Results The preeminent form of distributed electricity generation, grid-tied photovoltaic cells under net-metering, allow individual homeowners a degree of electric self-sufficiency while often turning a profit. However, substantial subsidies are required to make the investment sensible. Meanwhile, large dish Stirling engine installations have a significantly higher potential rate of return, but face a number of pragmatic limitations. Conclusions This paper concludes that both technologies are a sensible investment for consumers, but given that the dish Stirling consumer receives 6.37 dollars per watt while the home photovoltaic system consumer receives between 0.9 and 1.70 dollars per watt, the former appears to be a superior option. Despite the large investment, this paper deduces that it is far more feasible to get few strong investors to develop a solar farm of this magnitude, than to get 150,000 households to install photovoltaic arrays in their roofs. Potential implications of the solar farm construction include an environmental impact given the size of land require for this endeavour. However, the positive aspects, which include a large CO2 emission reduction aggregated over the lifespan of the farm

  8. The place of solar power: an economic analysis of concentrated and distributed solar power.

    PubMed

    Banoni, Vanessa Arellano; Arnone, Aldo; Fondeur, Maria; Hodge, Annabel; Offner, J Patrick; Phillips, Jordan K

    2012-04-23

    This paper examines the cost and benefits, both financial and environmental, of two leading forms of solar power generation, grid-tied photovoltaic cells and Dish Stirling Systems, using conventional carbon-based fuel as a benchmark. First we define how these solar technologies will be implemented and why. Then we delineate a model city and its characteristics, which will be used to test the two methods of solar-powered electric distribution. Then we set the constraining assumptions for each technology, which serve as parameters for our calculations. Finally, we calculate the present value of the total cost of conventional energy needed to power our model city and use this as a benchmark when analyzing both solar models' benefits and costs. The preeminent form of distributed electricity generation, grid-tied photovoltaic cells under net-metering, allow individual homeowners a degree of electric self-sufficiency while often turning a profit. However, substantial subsidies are required to make the investment sensible. Meanwhile, large dish Stirling engine installations have a significantly higher potential rate of return, but face a number of pragmatic limitations. This paper concludes that both technologies are a sensible investment for consumers, but given that the dish Stirling consumer receives 6.37 dollars per watt while the home photovoltaic system consumer receives between 0.9 and 1.70 dollars per watt, the former appears to be a superior option. Despite the large investment, this paper deduces that it is far more feasible to get few strong investors to develop a solar farm of this magnitude, than to get 150,000 households to install photovoltaic arrays in their roofs. Potential implications of the solar farm construction include an environmental impact given the size of land require for this endeavour. However, the positive aspects, which include a large CO2 emission reduction aggregated over the lifespan of the farm, outweigh any minor concerns or potential

  9. Full-scale monitoring system for structural prestress loss based on distributed brillouin sensing technique

    NASA Astrophysics Data System (ADS)

    Chunguang, Lan; Liguang, Zhou; Zhiyu, Huo

    2017-08-01

    Prestress loss is critical to impact the safety of prestressed structures. Unfortunately, up to date, there are no qualified techniques to handle this issue due to the fact that it is too hard for sensors to survive the harsh construction environments and the time-dependent service life of the large-span prestressed structures. This paper proposes a novel technique to monitor prestress loss in prestressed beams using Brillouin optical fiber sensors. A novel smart steel strand based on the sensing technique of full-scale Brillouin optical fiber sensors was introduced. Two kinds of prestressed structure were used to verify the concept of monitoring prestress loss using smart steel strands. The prestress loss data have been taken by Brillouin optical fiber sensors. And the monitoring results agree well with those from the conventional sensors. The monitoring data can reveal both the full-scale distribution and the time history of prestress loss during the construction stage and also in-service phrase.

  10. Loss Analysis of High Power Stirling-Type Pulse Tube Cryocooler

    NASA Astrophysics Data System (ADS)

    Nakano, K.; Hiratsuka, Y.

    2015-12-01

    For the purpose of cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES) and current fault limiters, cryocoolers should be compact in size, light-weight, and have high efficiency and reliability. In order to meet the demand of HTS devices world-wide, the cryocooler needs to have COP efficiency >0.1. We have developed a high power Stirling-type pulse tube cryocooler (SPTC) with an in-line expander. The experimental results were reported in June 2012[1]. The cooling capacity was 210 W at 77 K and the minimum temperature was 37 K when the compressor input power was 3.8 kW. Accordingly, the COP was about 0.055. To further improve the efficiency, the energy losses in the cryocooler were analyzed. The experimental results and the numerical calculation results are reported in this paper.

  11. Partial Shade Evaluation of Distributed Power Electronics for Photovoltaic Systems: Preprint

    SciTech Connect

    Deline, C.; Meydbrav, J.; Donovan, M.

    2012-06-01

    Site survey data for several residential installations are provided, showing the extent and frequency of shade throughout the year. This background information is used to design a representative shading test that is conducted on two side-by-side 8-kW photovoltaic (PV) installations. One system is equipped with a standard string inverter, while the other is equipped with microinverters on each solar panel. Partial shade is applied to both systems in a comprehensive range of shading conditions, simulating one of three shade extents. Under light shading conditions, the microinverter system produced the equivalent of 4% annual performance improvement, relative to the string inverter system. Under moderate shading conditions, the microinverter system outperformed the string inverter system by 8%, and under heavy shading the microinverter increased relative performance by 12%. In all three cases, the percentage of performance loss that is recovered by the use of distributed power electronics is 40%-50%. Additionally, it was found that certain shading conditions can lead to additional losses in string inverters due to peak-power tracking errors and voltage limitations.

  12. LIQHYSMES - spectral power distributions of imbalances and implications for the SMES

    NASA Astrophysics Data System (ADS)

    Sander, M.; Gehring, R.; Neumann, H.

    2014-05-01

    LIQHYSMES, the recently proposed hybrid energy storage concept for variable renewable energies, combines the storage of LIQuid HYdrogen (LH2) with Superconducting Magnetic Energy Storage (SMES). LH2 as the bulk energy carrier is used for the large scale stationary longer-term energy storage, and the SMES cooled by the LH2 bath, provides highest power over shorter periods and at superior efficiencies. Both together contribute to the balancing of electric load or supply fluctuations from seconds to several hours, days or even weeks. Here different spectral power distributions of such imbalances between electricity supply and load reflecting different sources of fluctuations in the range between 1 sec and 15 minutes are considered. Some related implications for MgB2-based 100 MW-SMES operated at maximum fields of 2 T and 4 T, are considered for these buffering scenarios. Requirements as regards the storage capacity and correspondingly the minimum size of the LH2 storage tank are derived. The related loss contributions with a particular focus on the ramping losses are analysed.

  13. Space vehicle electrical power processing distribution and control study. Volume 1: Summary

    NASA Technical Reports Server (NTRS)

    Krausz, A.

    1972-01-01

    A concept for the processing, distribution, and control of electric power for manned space vehicles and future aircraft is presented. Emphasis is placed on the requirements of the space station and space shuttle configurations. The systems involved are referred to as the processing distribution and control system (PDCS), electrical power system (EPS), and electric power generation system (EPGS).

  14. 29 CFR 1910.269 - Electric power generation, transmission, and distribution.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 5 2011-07-01 2011-07-01 false Electric power generation, transmission, and distribution... § 1910.269 Electric power generation, transmission, and distribution. Note: OSHA is staying the... the operation and maintenance of electric power generation, control, transformation, transmission, and...

  15. 29 CFR 1910.269 - Electric power generation, transmission, and distribution.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Electric power generation, transmission, and distribution... § 1910.269 Electric power generation, transmission, and distribution. Note: OSHA is staying the... the operation and maintenance of electric power generation, control, transformation, transmission, and...

  16. Wind Power Forecasting Error Distributions over Multiple Timescales: Preprint

    SciTech Connect

    Hodge, B. M.; Milligan, M.

    2011-03-01

    In this paper, we examine the shape of the persistence model error distribution for ten different wind plants in the ERCOT system over multiple timescales. Comparisons are made between the experimental distribution shape and that of the normal distribution.

  17. The distribution of absorptive power dissipation in irradiated nanoparticulate system

    NASA Astrophysics Data System (ADS)

    Li, Jiayu; Yang, Jian; Gu, Xiaobing

    2016-10-01

    The knowledge of local radiant absorption is important to the nanostructure optimization, it is beneficial to the applications in energy harvesting, optical heating, photocatalysis, etc. In this paper, FDTD model is constructed for the distribution of absorptive power dissipation in irradiated nanoparticulate system. The theoretical model extended from Mie theory is used to examine the FDTD model, the parameters and conditions set for FDTD simulation are confirmed based on the comparison. Then, the influence of Ag nanoparticle on the absorptive properties of nearby TiO2 nanoparticle is investigated by FDTD simulation at the wavelength of 0.25 μm. It is indicated that suitable distance between TiO2 and Ag particles is beneficial to the spectral radiant absorption of TiO2 particle. Considering the agglomeration of nanoparticles and the oxidation at the TiO2-Ag interface, the Ag core coated with Al2O3 shell is suggested, and the simulated results indicated that the shell thickness and the Ag core size need to be optimized for enhancing the radiant absorption of TiO2 particle.

  18. Applying model-based diagnostics to space power distribution

    NASA Astrophysics Data System (ADS)

    Quinn, Todd M.; Schlegelmilch, Richard F.

    1994-03-01

    When engineers diagnose system failures, they often use models to confirm system operation. This concept has produced a class of advanced expert systems which perform model-based diagnosis. A model-based diagnostic expert system for a Space Station Freedom electrical power distribution testbed is currently being developed at the NASA Lewis Research Center. The objective of this expert system is to autonomously detect and isolate electrical fault conditions. Marple, a software package developed at TRW, provides a model-based environment utilizing constraint suspension. Originally, constraint suspension techniques were developed for digital systems. However, Marple provides the mechanisms for applying this approach to analog systems, such as the testbed, as well. The expert system was developed using Marple and Lucid Common Lisp running on Sun Sparc-2 workstation. The Marple modeling environment has proved to be a useful tool for investigating the various aspects of model-based diagnostics. This paper describes work completed to date and lessons learned while employing model-based diagnostics using constraint suspension within an analog system.

  19. Analysis of Loss-of-Offsite-Power Events 1997-2015

    SciTech Connect

    Johnson, Nancy Ellen; Schroeder, John Alton

    2016-07-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1997 through 2015. LOOP events during critical operation that do not result in a reactor trip, are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). There is an adverse trend in LOOP durations. The previously reported adverse trend in LOOP frequency was not statistically significant for 2006-2015. Grid-related LOOPs happen predominantly in the summer. Switchyard-centered LOOPs happen predominantly in winter and spring. Plant-centered and weather-related LOOPs do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986 -1996 time period.

  20. Distributed solid state programmable thermostat/power controller

    NASA Technical Reports Server (NTRS)

    Alexander, Jane C. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2008-01-01

    A self-contained power controller having a power driver switch, programmable controller, communication port, and environmental parameter measuring device coupled to a controllable device. The self-contained power controller needs only a single voltage source to power discrete devices, analog devices, and the controlled device. The programmable controller has a run mode which, when selected, upon the occurrence of a trigger event changes the state of a power driver switch and wherein the power driver switch is maintained by the programmable controller at the same state until the occurrence of a second event.

  1. Transmission-reflection analysis for localization of temporally successive multipoint perturbations in a distributed fiber-optic loss sensor based on Rayleigh backscattering.

    PubMed

    Spirin, Vasilii V

    2003-03-01

    A novel method is presented for the localization of multipoint loss-inducing perturbations in a distributed fiber-optic sensor. The proposed simple technique is based on measurement of the transmitted and the Rayleigh-backscattered powers of an unmodulated light launched into a sensing fiber. The positions of consecutive perturbations are determined by measuring the slopes of the dependence of normalized Rayleigh-backscattering power versus the square of normalized transmitted power. It is shown that these slopes uniquely depend on the positions of the disturbances along the test fiber. The method allows localization of any number of the perturbations that appear one after another at different positions along the test fiber without ambiguity. Good agreement is obtained between calculated and experimentally measured slopes for a loss that was consecutively induced near the source and remote ends of 2.844-km-long fiber.

  2. In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing: Preprint

    SciTech Connect

    Spataru, Sergiu; Hacke, Pater; Sera, Dezso

    2015-09-15

    We analyze the degradation of multi-crystalline silicon photovoltaic modules undergoing simultaneous thermal, mechanical, and humidity stress testing to develop a dark environmental chamber in-situ measurement procedure for determining module power loss. From the analysis we determine three main categories of failure modes associated with the module degradation consisting of: shunting, recombination losses, increased series resistance losses, and current mismatch losses associated with a decrease in photo-current generation by removal of some cell areas due to cell fractures. Based on the analysis, we propose an in-situ module power loss monitoring procedure that relies on dark current-voltage measurements taken during the stress test, and initial and final module flash testing, to determine the power degradation characteristic of the module.

  3. Baseline Experimental Results on the Effect of Oil Temperature on Shrouded Meshed Spur Gear Windage Power Loss

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Hurrell, Michael James

    2017-01-01

    Rotorcraft gearbox efficiencies are reduced at increased surface speeds due to viscous and impingement drag on the gear teeth. This windage power loss can affect overall mission range, payload, and frequency of transmission maintenance. Experimental and analytical studies on shrouding for single gears have shown it be potentially effective in mitigating windage power loss. Efficiency studies on unshrouded meshed gears have shown the effect of speed, oil viscosity, temperature, load, lubrication scheme, etc. on gear windage power loss. The open literature does not cite data on shrouded meshed spur gears. Gear windage power loss test results are presented on shrouded meshed spur gears at elevated oil inlet temperatures and constant oil pressure both with and without shrouding. Shroud effectiveness is compared at four oil inlet temperatures. The results are compared to the available literature and follow-up work is outlined.

  4. Baseline Experimental Results on the Effect of Oil Temperature on Shrouded Meshed Spur Gear Windage Power Loss

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Hurrell, Michael

    2017-01-01

    Rotorcraft gearbox efficiencies are reduced at increased surface speeds due to viscous and impingement drag on the gear teeth. This windage power loss can affect overall mission range, payload, and frequency of transmission maintenance. Experimental and analytical studies on shrouding for single gears have shown it to be potentially effective in mitigating windage power loss. Efficiency studies on unshrouded meshed gears have shown the effect of speed, oil viscosity, temperature, load, lubrication scheme, etc. on gear windage power loss. The open literature does not contain experimental test data on shrouded meshed spur gears. Gear windage power loss test results are presented on shrouded meshed spur gears at elevated oil inlet temperatures and constant oil pressure both with and without shrouding. Shroud effectiveness is compared at four oil inlet temperatures. The results are compared to the available literature and follow-up work is outlined.

  5. Minimization of power losses in hybrid electric vehicles in view of the prolonging of battery life

    NASA Astrophysics Data System (ADS)

    Amiri, Meisam; Esfahanian, Mohsen; Hairi-Yazdi, Mohammad Reza; Esfahanian, Vahid

    Hybrid Electric Vehicles (HEVs) are becoming more popular than pure electric ones, nowadays. This is because of their better performance, economic advantages and higher operating range. However, their potential advantages extremely depend on their system design, most importantly their battery system design. Batteries' life requirements as well as the cost of replacing them at the end of their life period, currently limit manufacturers to bring HEVs into play, even though their fuel economy reduces their everyday cost considerably. Generally, inappropriate discharge/charge patterns would result in loss in batteries' life. In the present study, an optimization based control strategy has been proposed for the series HEVs in order to maximize the efficiency of the power-train while minimizing the loss. A genetic algorithm is implemented to optimally evaluate the control algorithm's parameters. The approach is then compared to two main control strategies, namely thermostatic control strategy and power follower control strategy. The computational procedure of the genetic algorithm is discussed, and a simulation study based on a model of a series hybrid electric vehicle is given to validate the genetic algorithm results.

  6. Gyroharmonic maser instability for weakly relativistic electrons with a loss-cone distribution

    NASA Technical Reports Server (NTRS)

    Yoon, Peter H.; Krauss-Varban, D.

    1990-01-01

    The weakly relativisitic dielectric tensor for a system of electrons comprised of cold and energetic populations, embedded in a neutralizing background, is reformulated in terms of an infinite series representation in powers of lamba = alpha ck(perpendicular)/omega (c), where alpha-squared is a parameter proportional to the average thermal energy of the energetic electrons, k(perpendicular) is the perpendicular component of the wave vector k, and omega (c) is the electron gyrofrequency. The energetic electrons are assumed to have a loss-cone feature in the perpendicular momentum space. The present formalism can be used in the problem of cyclotron maser as well as more general gyroharmonic maser (i.e., multiharmonics) emissions resulting from weakly relativistic loss-cone electrons. This is because, unlike the previous theories in which certain approximations such as the single-harmonic approximations are made, the present formalism retains contributions from the entire harmonics.

  7. Complex additive systems for Mn-Zn ferrites with low power loss

    SciTech Connect

    Töpfer, J. Angermann, A.

    2015-05-07

    Mn-Zn ferrites were prepared via an oxalate-based wet-chemical synthesis process. Nanocrystalline ferrite powders with particle size of 50 nm were sintered at 1150 °C with 500 ppm CaO and 100 ppm SiO{sub 2} as standard additives. A fine-grained, dense microstructure with grain size of 4–5 μm was obtained. Simultaneous addition of Nb{sub 2}O{sub 5}, ZrO{sub 2}, V{sub 2}O{sub 5}, and SnO{sub 2} results low power losses, e.g., 65 mW/cm{sup 3} (500 kHz, 50 mT, 80 °C) and 55 mW/cm{sup 3} (1 MHz, 25 mT, 80 °C). Loss analysis shows that eddy current and residual losses were minimized through formation of insulating grain boundary phases, which is confirmed by transmission electron microscopy. Addition of SnO{sub 2} increases the ferrous ion concentration and affects anisotropy as reflected in permeability measurements μ(T)

  8. Neuroanatomical and resting state EEG power correlates of central hearing loss in older adults.

    PubMed

    Giroud, Nathalie; Hirsiger, Sarah; Muri, Raphaela; Kegel, Andrea; Dillier, Norbert; Meyer, Martin

    2017-07-22

    To gain more insight into central hearing loss, we investigated the relationship between cortical thickness and surface area, speech-relevant resting state EEG power, and above-threshold auditory measures in older adults and younger controls. Twenty-three older adults and 13 younger controls were tested with an adaptive auditory test battery to measure not only traditional pure-tone thresholds, but also above individual thresholds of temporal and spectral processing. The participants' speech recognition in noise (SiN) was evaluated, and a T1-weighted MRI image obtained for each participant. We then determined the cortical thickness (CT) and mean cortical surface area (CSA) of auditory and higher speech-relevant regions of interest (ROIs) with FreeSurfer. Further, we obtained resting state EEG from all participants as well as data on the intrinsic theta and gamma power lateralization, the latter in accordance with predictions of the Asymmetric Sampling in Time hypothesis regarding speech processing (Poeppel, Speech Commun 41:245-255, 2003). Methodological steps involved the calculation of age-related differences in behavior, anatomy and EEG power lateralization, followed by multiple regressions with anatomical ROIs as predictors for auditory performance. We then determined anatomical regressors for theta and gamma lateralization, and further constructed all regressions to investigate age as a moderator variable. Behavioral results indicated that older adults performed worse in temporal and spectral auditory tasks, and in SiN, despite having normal peripheral hearing as signaled by the audiogram. These behavioral age-related distinctions were accompanied by lower CT in all ROIs, while CSA was not different between the two age groups. Age modulated the regressions specifically in right auditory areas, where a thicker cortex was associated with better auditory performance in older adults. Moreover, a thicker right supratemporal sulcus predicted more rightward theta

  9. Practical Considerations For Optical Power Loss Measurements During Outside Plant Installations

    NASA Astrophysics Data System (ADS)

    Grebe, Robert K.; Caron, Bernard G.

    1984-08-01

    The techniques for predicting total transmission system losses in a fiber optic cable installation involving multiple splices are relatively well known, and significant work has been done in the field of laboratory measurement techniques for quantifying cable (fiber) characteristics and performance characteristics of splices and connectors. The shift of this technology from the laboratory to the actual environment of a field installation, however, poses some significantly different problems to the user of fiber optic cables and splices. The basic instrument available for field use in testing optical links is the Optical-Time-Domain-Reflectometer (OTDR). An OTDR can be used to check the loss profile (dB/km) of a fiber within a cable prior to the cable installation, and to locate installation induced faults in the cable. The capability of the OTDR above to characterize splice losses in an actual installation can be significantly degraded depending on the location of the splice with respect to cable faults, the length of the cable (fiber) run, the characteristics of the individual fibers being spliced, and the ability of the OTDR operator to interpret the-data the instrument is presenting. By following some specific procedures regarding the sequence of installation and testing, and through better understanding of the performance of optical fibers and splices where actually installed in the outside plant environment, installation crews can significantly reduce installation time and time lost because of faults in an individual link that must be reworked. Addi-tional testing with instruments specifically intended for optical power measurement can provide a realistic basis for evaluation of the overall performance of a completely installed link and will give the transmission engineer a solid reference base for use in system set-up in addition to evaluation of system deterioration. Records made through OTDR measurements and optical power instrument readings can be used to

  10. Poynting flux in the neighbourhood of a point charge in arbitrary motion and radiative power losses

    NASA Astrophysics Data System (ADS)

    Singal, Ashok K.

    2016-07-01

    We examine the electromagnetic fields in the neighbourhood of a ‘point charge’ in arbitrary motion and thereby determine the Poynting flux across a spherical surface of vanishingly small radius surrounding the charge. We show that the radiative power losses from a point charge turn out to be proportional to the scalar product of the instantaneous velocity and the first time-derivative of the acceleration of the charge. This may seem to be discordant with the familiar Larmor formula where the instantaneous power radiated from a charge is proportional to the square of acceleration. However, it seems that the root cause of the discrepancy actually lies in Larmor’s formula, which is derived using the acceleration fields but without due consideration for the Poynting flux associated with the velocity-dependent self-fields ‘co-moving’ with the charge. Further, while deriving Larmor’s formula, one equates the Poynting flux through a surface at some later time to the radiation loss by the enclosed charge at the retarded time. Poynting’s theorem, on the other hand, relates the outgoing radiation flux from a closed surface to the rate of energy decrease within the enclosed volume, all calculated for the same given instant only. Here we explicitly show the absence of any Poynting flux in the neighbourhood of an instantly stationary point charge, implying no radiative losses from such a charge, which is in complete conformity with energy conservation. We further show how Larmor’s formula is still able to serve our purpose in the vast majority of cases. It is further shown that Larmor’s formula in general violates momentum conservation and, in the case of synchrotron radiation, leads to a potentially incorrect conclusion about the pitch angle changes of the radiating charges, and that only the radiation reaction formula yields a correct result, consistent with special relativity.

  11. The Role of Distributed Generation and Combined Heat and Power (CHP) Systems in Data Centers

    EPA Pesticide Factsheets

    This report reviews how distributed generation (DG) resources such as fuel cells, reciprocating engines, and gas turbines can offer powerful energy efficiency savings in data centers, particularly when configured in combined heat and power (CHP) mode.

  12. Watershed Scale Stable Isotope Distribution and Implications on Soil Organic Carbon Loss Monitoring under Hydrologic Uncertainty

    NASA Astrophysics Data System (ADS)

    Ahmed, I.; Karim, A.; Boutton, T. W.; Strom, K.; Fox, J.

    2013-12-01

    The thematic focus of this 3-year period multidisciplinary USDA-CBG collaborative applied research is integrated monitoring of soil organic carbon (SOC) loss from multi-use lands using state-of-the-art stable isotope science under uncertain hydrologic influences. In this study, SOC loss and water runoff are being monitored on a 150 square kilometer watershed in Houston, Texas, using natural rainfall events, and total organic carbon/nitrogen concentration (TOC/TN) and stable isotope ratio (δ13C, δ15N) measurements with different land-use types. The work presents the interdisciplinary research results to uncover statistically valid and scientifically sound ways to monitor SOC loss by (i) application of Bayesian Markov Chain Monte Carlo statistical models to assess the relationship between rainfall-runoff and SOC release during soil erosion in space and time, (ii) capturing the episodic nature of rainfall events and its role in the spatial distribution of SOC loss from water erosion, (iii) stable isotope composition guided fingerprinting (source and quantity) of SOC by considering various types of erosion processes common in a heterogeneous watershed, to be able to tell what percentage of SOC is lost from various land-use types (Fox and Papanicolaou, 2008), (iv) creating an integrated watershed scale statistical soil loss monitoring model driven by spatial and temporal correlation of flow and stable isotope composition (Ahmed et. al., 2013a,b), and (v) creation of an integrated decision support system (DSS) for sustainable management of SOC under hydrologic uncertainty to assist the end users. References: Ahmed, I., Karim, A., Boutton, T.W., and Strom, K.B. (2013a). 'Monitoring Soil Organic Carbon Loss from Erosion Using Stable Isotopes.' Proc., Soil Carbon Sequestration, International Conference, May 26-29, Reykjavik, Iceland. Ahmed, I, Bouttom, T.W., Strom, K. B., Karim, A., and Irvin-Smith, N. (2013b). 'Soil carbon distribution and loss monitoring in the

  13. Power distribution in complex environmental negotiations: Does balance matter?

    USGS Publications Warehouse

    Burkardt, N.; Lamb, B.L.; Taylor, J.G.

    1997-01-01

    We studied six interagency negotiations covering Federal Energy Regulatory Commission (FERC) hydroelectric power licenses. Negotiations occurred between state and federal resource agencies and developers over project operations and natural resource mitigation. We postulated that a balance of power among parties was necessary for successful negotiations. We found a complex relationship between balanced power and success and conclude that a balance of power was associated with success in these negotiations. Power played a dynamic role in the bargaining and illuminates important considerations for regulatory design.

  14. A PLANAR, RECTANGULAR WAVEGUIDE LAUNCHER AND EXTRACTOR FOR A DUAL-MODED RF POWER DISTRIBUTION SYSTEM

    SciTech Connect

    Nantista, Christopher D.

    2000-11-21

    The desire to reduce the amount of low-loss, circular-waveguide delay line required in a pulse-compressing power distribution system for the Next Linear Collider has led to the pursuit of multi-moded schemes [1]. In such a system, power is delivered to different destinations through the same waveguide via different propagating modes. Current plans [2] utilize two modes, with manipulations done primarily in overmoded rectangular guide. We describe two key components of the system, a four-input/four-output, dual-mode launcher and an extractor for diverting one mode from the delay line to an accelerator feed while allowing the other to pass on to an upstream feed. These novel passive waveguide devices utilize the rectangular TE10 and TE20 modes. Because they must carry up to 600 MW pulsed rf power, H-planar symmetry is maintained in their designs to allow the use of overheight waveguide, and features that invite breakdown, such as coupling slots, irises, and septa, are avoided. Special rectangular-to-circular tapers [3] will be used to convert between the above modes and the circular TE11{sup o} (TE12{sup o}) and TE01{sup o} delay line modes, respectively. Rectangular waveguide for relative ease of handling. Mode converters, including special cross-section tapers [3] will be used to transform between the above circular waveguide modes and the TE20 and TE10 rectangular waveguide modes, respectively.

  15. Structured Coupling of Probability Loss Distributions: Assessing Joint Flood Risk in Multiple River Basins.

    PubMed

    Timonina, Anna; Hochrainer-Stigler, Stefan; Pflug, Georg; Jongman, Brenden; Rojas, Rodrigo

    2015-11-01

    Losses due to natural hazard events can be extraordinarily high and difficult to cope with. Therefore, there is considerable interest to estimate the potential impact of current and future extreme events at all scales in as much detail as possible. As hazards typically spread over wider areas, risk assessment must take into account interrelations between regions. Neglecting such interdependencies can lead to a severe underestimation of potential losses, especially for extreme events. This underestimation of extreme risk can lead to the failure of riskmanagement strategies when they are most needed, namely, in times of unprecedented events. In this article, we suggest a methodology to incorporate such interdependencies in risk via the use of copulas. We demonstrate that by coupling losses, dependencies can be incorporated in risk analysis, avoiding the underestimation of risk. Based on maximum discharge data of river basins and stream networks, we present and discuss different ways to couple loss distributions of basins while explicitly incorporating tail dependencies. We distinguish between coupling methods that require river structure data for the analysis and those that do not. For the later approach we propose a minimax algorithm to choose coupled basin pairs so that the underestimation of risk is avoided and the use of river structure data is not needed. The proposed methodology is especially useful for large-scale analysis and we motivate and apply our method using the case of Romania. The approach can be easily extended to other countries and natural hazards.

  16. Associations between Obesity, Body Fat Distribution, Weight Loss and Weight Cycling on Serum Pesticide Concentrations

    PubMed Central

    Frugé, Andrew Dandridge; Cases, Mallory Gamel; Schildkraut, Joellen Martha; Demark-Wahnefried, Wendy

    2016-01-01

    Objective Preliminary studies suggest pesticides may be linked to increased cancer risk. Since most pesticides are lipophilic and stored within adipose tissue, serum levels of organochlorines are affected not only by environmental exposures, but also by factors related to lipid turnover and storage. Our objective was to investigate whether serum organochlorines are influenced by weight loss, body fat distribution, and weight cycling. Methods Ten overweight women were recruited upon entry into a weight loss program and surveyed regarding weight history, childbearing/lactation, and exposure to environmental contaminants. Anthropometric measures and phlebotomy were conducted at baseline and at four weeks (mean weight loss=5.1 kg). Serum was analyzed for 19 common polychlorinated pesticides and metabolites and 10 PCB congeners. Results Organochlorine levels were not significantly affected by weight loss nor associated with body mass index (BMI). Strong positive correlations were noted between levels of DDE/DDT and age (DDE β=0.6986/p=0.0246/DDT β=0.6536/p=0.0404) and between DDE/DDT and waist-to-hip ratio (WHR) (DDE β=0.4356/p=0.0447/DDT β=0.8108/p=0.0044). Trends were noted for decreased levels of DDT in women who reported more episodes of weight cycling. Conclusion Serum organochlorine levels may be affected not only by age, but also factors related to lipid turnover (i.e., episodes of weight cycling and WHR), and warrants further study. PMID:27478857

  17. Spatial variation in water loss predicts terrestrial salamander distribution and population dynamics.

    PubMed

    Peterman, W E; Semlitsch, R D

    2014-10-01

    Many patterns observed in ecology, such as species richness, life history variation, habitat use, and distribution, have physiological underpinnings. For many ectothermic organisms, temperature relationships shape these patterns, but for terrestrial amphibians, water balance may supersede temperature as the most critical physiologically limiting factor. Many amphibian species have little resistance to water loss, which restricts them to moist microhabitats, and may significantly affect foraging, dispersal, and courtship. Using plaster models as surrogates for terrestrial plethodontid salamanders (Plethodon albagula), we measured water loss under ecologically relevant field conditions to estimate the duration of surface activity time across the landscape. Surface activity time was significantly affected by topography, solar exposure, canopy cover, maximum air temperature, and time since rain. Spatially, surface activity times were highest in ravine habitats and lowest on ridges. Surface activity time was a significant predictor of salamander abundance, as well as a predictor of successful recruitment; the probability of a juvenile salamander occupying an area with high surface activity time was two times greater than an area with limited predicted surface activity. Our results suggest that survival, recruitment, or both are demographic processes that are affected by water loss and the ability of salamanders to be surface-active. Results from our study extend our understanding of plethodontid salamander ecology, emphasize the limitations imposed by their unique physiology, and highlight the importance of water loss to spatial population dynamics. These findings are timely for understanding the effects that fluctuating temperature and moisture conditions predicted for future climates will have on plethodontid salamanders.

  18. Status of 20 kHz space station power distribution technology

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1988-01-01

    Power Distribution on the NASA Space Station will be accomplished by a 20 kHz sinusoidal, 440 VRMS, single phase system. In order to minimize both system complexity and the total power coversion steps required, high frequency power will be distributed end-to-end in the system. To support the final design of flight power system hardware, advanced development and demonstrations have been made on key system technologies and components. The current status of this program is discussed.

  19. Improving Power Quality and Distribution Efficiency in Micro-Grids by Plug & Play Control of Switching Power Interfaces

    NASA Astrophysics Data System (ADS)

    Tenti, Paolo; Costabeber, Alessandro; Mattavelli, Paolo

    Smart grids offer a wide application domain for power electronics. In fact, every distributed generator (DG) includes an electronic power processor (Switching Power Interface, SPI) which controls the currents drawn from the grid and can be driven to optimize the power flow, improve voltage stability and increase distribution efficiency. For these aims, such distributed SPIs must perform cooperatively. This is true also in low-voltage residential micro-grids, where the number of active DGs and the generated power may vary during daytime, thus requiring dynamic adaptation of SPI operation. To achieve this goal different approaches can be adopted, depending on the available communication capability. This paper discusses various control solutions applicable in absence of supervisory control, e. g., in residential micro-grids, where communication is possible between neighbor units only (surround control) or is not available at all (plug & play control).

  20. Advanced Power Electronics Interfaces for Distributed Energy Workshop Summary: August 24, 2006, Sacramento, California

    SciTech Connect

    Treanton, B.; Palomo, J.; Kroposki, B.; Thomas, H.

    2006-10-01

    The Advanced Power Electronics Interfaces for Distributed Energy Workshop, sponsored by the California Energy Commission Public Interest Energy Research program and organized by the National Renewable Energy Laboratory, was held Aug. 24, 2006, in Sacramento, Calif. The workshop provided a forum for industry stakeholders to share their knowledge and experience about technologies, manufacturing approaches, markets, and issues in power electronics for a range of distributed energy resources. It focused on the development of advanced power electronic interfaces for distributed energy applications and included discussions of modular power electronics, component manufacturing, and power electronic applications.