Science.gov

Sample records for power loss distribution

  1. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  2. Distribution network reconfiguration for energy loss reduction

    SciTech Connect

    Taleski, R.; Rajicic, D.

    1997-02-01

    A new method for energy loss reduction for distribution networks is presented. It is based on known techniques and algorithms for radial network analysis--oriented element ordering, power summation method for power flow, statistical representation of load variations, and a recently developed energy summation method for computation of energy losses. These methods, combined with the heuristic rules developed to lead the iterative process, make the energy loss minimization method effective, robust and fast. It presents an alternative to the power minimization methods for operation and planning purposes.

  3. A study using a Monte Carlo method of the optimal configuration of a distribution network in terms of power loss sensing.

    PubMed

    Moon, Hyun Ho; Lee, Jong Joo; Choi, Sang Yule; Cha, Jae Sang; Kang, Jang Mook; Kim, Jong Tae; Shin, Myong Chul

    2011-01-01

    the distribution loss associated with power distribution systems focus on sensing aspect and distributed power generation.

  4. Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2.

    SciTech Connect

    Dionne, B.; Tzanos, C. P.

    2011-05-23

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

  5. A Study Using a Monte Carlo Method of the Optimal Configuration of a Distribution Network in Terms of Power Loss Sensing

    PubMed Central

    Moon, Hyun Ho; Lee, Jong Joo; Choi, Sang Yule; Cha, Jae Sang; Kang, Jang Mook; Kim, Jong Tae; Shin, Myong Chul

    2011-01-01

    design, which considers the distribution loss associated with power distribution systems focus on sensing aspect and distributed power generation. PMID:22164047

  6. Exponentiated power Lindley distribution.

    PubMed

    Ashour, Samir K; Eltehiwy, Mahmoud A

    2015-11-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data.

  7. Exponentiated power Lindley distribution

    PubMed Central

    Ashour, Samir K.; Eltehiwy, Mahmoud A.

    2014-01-01

    A new generalization of the Lindley distribution is recently proposed by Ghitany et al. [1], called as the power Lindley distribution. Another generalization of the Lindley distribution was introduced by Nadarajah et al. [2], named as the generalized Lindley distribution. This paper proposes a more generalization of the Lindley distribution which generalizes the two. We refer to this new generalization as the exponentiated power Lindley distribution. The new distribution is important since it contains as special sub-models some widely well-known distributions in addition to the above two models, such as the Lindley distribution among many others. It also provides more flexibility to analyze complex real data sets. We study some statistical properties for the new distribution. We discuss maximum likelihood estimation of the distribution parameters. Least square estimation is used to evaluate the parameters. Three algorithms are proposed for generating random data from the proposed distribution. An application of the model to a real data set is analyzed using the new distribution, which shows that the exponentiated power Lindley distribution can be used quite effectively in analyzing real lifetime data. PMID:26644927

  8. Optimal loss reduction of distribution networks

    SciTech Connect

    Glamocanin, V. )

    1990-08-01

    A new algorithm for network reconfiguration of power distribution systems is presented. An optimal loss reduction is accomplished to maintain acceptable voltage at customer loads as well as to assure sufficient conductor and substation current capacity to handle load requirements. The success of the algorithm depends directly upon the straightforward and highly-efficient solution of quadratic cost transshipment problem. The new algorithm, described in this paper, completely eliminates the need for matrix operations and executes all operations directly on graph of the distribution system.

  9. Industrial power distribution

    SciTech Connect

    Sorrells, M.A.

    1990-01-01

    This paper is a broad overview of industrial power distribution. Primary focus will be on selection of the various low voltage components to achieve the end product. Emphasis will be on the use of national standards to ensure a safe and well designed installation.

  10. Dielectric loss against piezoelectric power harvesting

    NASA Astrophysics Data System (ADS)

    Liang, Junrui; Shu-Hung Chung, Henry; Liao, Wei-Hsin

    2014-09-01

    Piezoelectricity is one of the most popular electromechanical transduction mechanisms for constructing kinetic energy harvesting systems. When a standard energy harvesting (SEH) interface circuit, i.e., bridge rectifier plus filter capacitor, is utilized for collecting piezoelectric power, the previous literature showed that the power conversion can be well predicted without much consideration for the effect of dielectric loss. Yet, as the conversion power gets higher by adopting power-boosting interface circuits, such as synchronized switch harvesting on inductor (SSHI), the neglect of dielectric loss might give rise to deviation in harvested power estimation. Given the continuous progress on power-boosting interface circuits, the role of dielectric loss in practical piezoelectric energy harvesting (PEH) systems should receive attention with better evaluation. Based on the integrated equivalent impedance network model, this fast track communication provides a comprehensive study on the susceptibility of harvested power in PEH systems under different conditions. It shows that, dielectric loss always counteracts piezoelectric power harvesting by causing charge leakage across piezoelectric capacitance. In particular, taking corresponding ideal lossless cases as references, the counteractive effect might be aggravated under one of the five conditions: larger dielectric loss tangent, lower vibration frequency, further away from resonance, weaker electromechanical coupling, or using power-boosting interface circuit. These relationships are valuable for the study of PEH systems, as they not only help explain the role of dielectric loss in piezoelectric power harvesting, but also add complementary insights for material, structure, excitation, and circuit considerations towards holistic evaluation and design for practical PEH systems.

  11. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Ashworth, Barry; Riedesel, Joel; Myers, Chris; Miller, William; Jones, Ellen F.; Freeman, Kenneth; Walsh, Richard; Walls, Bryan K.; Weeks, David J.; Bechtel, Robert T.

    1992-01-01

    Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.

  12. The Unseen Power Loss: Stemming the Flow.

    ERIC Educational Resources Information Center

    Gillett, Raphael

    2002-01-01

    Outlined an estimate-substitution strategy for a test comparing two means and developed an expected-power formula for the test. Demonstrated that for empirically representative distributions of effect size in psychology, the expected power deficit is large. (SLD)

  13. power loss in SSPX

    NASA Astrophysics Data System (ADS)

    Stewart, T. L.; Romero-Talamas, C. A.; McLean, H. S.; Correll, D. L.

    2007-11-01

    An absolute calibration has been performed on each of the seven chords of the Hα diagnostic [Z. Wang, G.A. Wurden, C.W Barnes, et al., Rev. Sci. Instrum. 72, 1059 (2001)] at SSPX. Simple models are used to estimate the total power lost to Hα radiation throughout experimental shots. Using these models, high energy shots (Te > 500 eV) are compared to low energy shots.

  14. SSP Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Lynch, Thomas H.; Roth, A. (Technical Monitor)

    2000-01-01

    Space Solar Power is a NASA program sponsored by Marshall Space Flight Center. The Paper presented here represents the architectural study of a large power management and distribution (PMAD) system. The PMAD supplies power to a microwave array for power beaming to an earth rectenna (Rectifier Antenna). The power is in the GW level.

  15. Distributed Space Solar Power

    NASA Technical Reports Server (NTRS)

    Fork, Richard L.

    2001-01-01

    The objective was to assess the feasibility of safely collecting solar power at geostationary orbit and delivering it to earth. A strategy which could harness a small fraction of the millions of gigawatts of sunlight passing near earth could adequately supply the power needs of earth and those of space exploration far into the future. Light collected and enhanced both spatially and temporally in space and beamed to earth provides probably the only practical means of safe and efficient delivery of this space solar power to earth. In particular, we analyzed the feasibility of delivering power to sites on earth at a comparable intensity, after conversion to a usable form, to existing power needs. Two major obstacles in the delivery of space solar power to earth are safety and the development of a source suitable for space. We focused our approach on: (1) identifying system requirements and designing a strategy satisfying current eye and skin safety requirements; and (2) identifying a concept for a potential space-based source for producing the enhanced light.

  16. Minimum loss power flow in hydro thermal electric power systems based on Kron's loss formula

    SciTech Connect

    Ravindranath, K.M.; El-Hawary, M.E.

    1989-01-01

    The authors discuss the formulation of the optimal minimum loss hydro-thermal power flow problem in electric power systems on the basis of Kron's loss formula as the objective function. Results of computational experience with a Newton's iterative implementation using two standard test systems. The conclusion is that it is extremely important to have an accurate loss model representation due to the potential errors as well as slow and difficult convergence behavior of the process.

  17. Power management and distribution technology

    NASA Technical Reports Server (NTRS)

    Dickman, John Ellis

    1993-01-01

    Power management and distribution (PMAD) technology is discussed in the context of developing working systems for a piloted Mars nuclear electric propulsion (NEP) vehicle. The discussion is presented in vugraph form. The following topics are covered: applications and systems definitions; high performance components; the Civilian Space Technology Initiative (CSTI) high capacity power program; fiber optic sensors for power diagnostics; high temperature power electronics; 200 C baseplate electronics; high temperature component characterization; a high temperature coaxial transformer; and a silicon carbide mosfet.

  18. Loss Reduction on Adoption of High Voltage LT Less Distribution

    NASA Astrophysics Data System (ADS)

    Tiwari, Deepika; Adhikari, Nikhileshwar Prasad; Gupta, Amit; Bajpai, Santosh Kumar

    2016-06-01

    In India there is a need to improve the quality of the electricity distribution process which has increased varying from year to year. In distribution networks, the limiting factor to load carrying capacity is generally the voltage reduction. High voltage distribution system (HVDS) is one of the steps to reduce line losses in electrical distribution network. It helps to reduce the length of low tension (LT) lines and makes the power available close to the users. The high voltage power distribution system reduces the probability of power theft by hooking HVDS suggests an increase in installation of small capacity single-phase transformers in the network which again save considerable energy. This paper is compared to existing conventional low tension distribution network with HVDS. The paper gives a clear picture of reduction in distribution losses with adoption of HVDS system. Losses Reduction of 11 kV Feeder in Nuniya (India) with adoption of HVDS have been worked out/ quantified and benefits thereby in generating capacity have discussed.

  19. Minimum loss reconfiguration of unbalanced distribution networks

    SciTech Connect

    Borozan, V.; Rajicic, D.; Ackovski, R.

    1997-01-01

    A heuristic method for determining the configuration with minimum resistive line losses for three-phase unbalanced distribution networks is described. This method is based on previous papers dealing with balanced network. Using a fast and reliable load flow solution technique and also, efficient algorithms for network elements inspection, so that methodology becomes capable to solve the challenging problem while still maintaining a high execution speed. A developed algorithm is applied on a practical distribution network. Performed analysis highlight the influence of load imbalances on a solution of minimum loss reconfiguration problem.

  20. Line Loss Minimization of Loop Distribution Systems Using UPFC

    NASA Astrophysics Data System (ADS)

    Sayed, Mahmoud A.; Inayoshi, Nobuyuki; Takeshita, Takaharu; Ueda, Fukashi

    This paper presents an elaborated mathematical analysis of the line loss minimum conditions of loop distribution systems. In order to achieve these conditions, the Unified Power Flow Controller (UPFC), a typical Flexible AC Transmission Systems (FACTS) device that is capable of instantaneous control of transmission and distribution power flow, is used. For minimizing the total line loss of the loop distribution system, the authors propose two control schemes, the Line Inductance Compensation control and the Line Voltage Compensation control. These control schemes can be applied for controlling the UPFC in the loop distribution system according to the line parameters. The effectiveness of the proposed control schemes has been verified experimentally using a laboratory prototype in a 200V, 6kVA system.

  1. Distributed Generators Allocation in Radial Distribution Systems with Load Growth using Loss Sensitivity Approach

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Vijay Babu, P.; Murty, V. V. S. N.

    2016-07-01

    Rapidly increasing electricity demands and capacity shortage of transmission and distribution facilities are the main driving forces for the growth of distributed generation (DG) integration in power grids. One of the reasons for choosing a DG is its ability to support voltage in a distribution system. Selection of effective DG characteristics and DG parameters is a significant concern of distribution system planners to obtain maximum potential benefits from the DG unit. The objective of the paper is to reduce the power losses and improve the voltage profile of the radial distribution system with optimal allocation of the multiple DG in the system. The main contribution in this paper is (i) combined power loss sensitivity (CPLS) based method for multiple DG locations, (ii) determination of optimal sizes for multiple DG units at unity and lagging power factor, (iii) impact of DG installed at optimal, that is, combined load power factor on the system performance, (iv) impact of load growth on optimal DG planning, (v) Impact of DG integration in distribution systems on voltage stability index, (vi) Economic and technical Impact of DG integration in the distribution systems. The load growth factor has been considered in the study which is essential for planning and expansion of the existing systems. The technical and economic aspects are investigated in terms of improvement in voltage profile, reduction in total power losses, cost of energy loss, cost of power obtained from DG, cost of power intake from the substation, and savings in cost of energy loss. The results are obtained on IEEE 69-bus radial distribution systems and also compared with other existing methods.

  2. Loss of 115 kV Power

    SciTech Connect

    Smith, J.A.

    2001-08-22

    This report discusses the postulated loss of 115 kV power. Continuous electrical power to Savannah River Plant reactors is necessary to maintain water flow for heat removal and essential monitoring and control. Should power supplied to the plant 115 kV system from offsite be lost, on-site generation is sufficient to maintain all reactors in a safe shutdown mode for an indefinite period. Should on-site generators for the 115 kV grid also be lost, diesel-electric generators within each reactor building are also sufficient to maintain safe shutdown for a finite period. In all cases DC power for necessary monitoring and control would be available from battery systems with AC converter backup.

  3. Passive Microwave Power Distribution Systems.

    DTIC Science & Technology

    wavelength by switching a reciprocal latching ferrite phase shifter in the stub, in response to termination of microwave power from one of the feed tubes....A standby microwave transmitter power amplifier tube is switched into a microwave power distribution system for a phased array in microseconds when...after the switching is completed, the switching being accomplished by changing electrical length of a quarter-wavelength waveguide stub to one-half

  4. Linguistic Model for Engine Power Loss

    DTIC Science & Technology

    2011-11-27

    model, engine power loss, intelligent diagnostics 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Public Release 18. NUMBER OF PAGES...module via a wireless interface that is compliant with the IEEE 802.15 protocol. The wireless personal area network is implemented using the ZigBee ... secure short range wireless communications link, or via a wired Ethernet port to a mobile device (e.g., another laptop computer authorized for CBM

  5. Wealth distribution on complex networks with losses

    NASA Astrophysics Data System (ADS)

    Wang, Fei; Fang, Weiguo

    2015-07-01

    Wealth distribution plays an important role in the field of econophysics. In this paper, this issue is investigated based on the Bouchaud and Mézard (BM) wealth distribution model by the method of complex networks in this paper. Previous reports usually assumed that wealth increased steadily or was transferred from one agent to another. However, wealth may be lost due to some natural disasters or incidents. Therefore, we introduce terms representing losses in the BM model to describe the economic behavior more precisely. We find that an anti-degree preference helps to create an equitable economic environment. The Gini coefficient of the wealth distribution is calculated, and an optimized preferential parameter is obtained for both the case with losses and the case without losses. For variable values of the parameter, the corresponding results are obtained and discussed. If network topologies are considered, we find that a homogeneous network prompts an equitable economic environment. Simulations prove that losses enlarge the rich-poor gap.

  6. Power Law Distribution in Education

    NASA Astrophysics Data System (ADS)

    Gupta, Hari M.; Campanha, José R.; Prado, Fernando D.

    We studied the statistical distribution of candidate's performance which is measured through their marks in university entrance examination (Vestibular) of UNESP (Universidade Estadual Paulista) for years 1998, 1999, and 2000. All students are divided in three groups: Physical, Biological and Humanities. We paid special attention to the examination of Portuguese language which is common for all and examinations for the particular area. We observed long ubiquitous power law tails in Physical and Biological sciences. This indicate the presence of strong positive feedback in sciences. We are able to explain completely these statistical distributions through Gradually Truncated Power law distributions which we developed recently to explain statistical behavior of financial market. The statistical distribution in case of Portuguese language and humanities is close to normal distribution. We discuss the possible reason for this peculiar behavior.

  7. ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

    SciTech Connect

    Tuffner, Francis K.; Singh, Ruchi

    2011-08-09

    Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

  8. Calculation method for line loss in 10kV distribution grid planning

    NASA Astrophysics Data System (ADS)

    Xiao, Ming-hui; Lin, Ling-xue; Liu, Si-yuan

    2017-01-01

    Distribution grid line loss index is an important indicator of running and managing a distribution grid. A general feature in distribution network is its difficulty in gathering data about structure and operation. Based on its feature, this paper proposed a method for calculating line loss in 10kV distribution grid from the perspective of planning. According to the characteristics of power consumption on different location of the feeder, line loss can be divided into three parts, including the main line loss, the loss of branch line and the loss of distribution transformer. The proposed method achieved quick calculation and component analysis. Distributed coefficient was calculated by analyzing different distributed situation of load on feeder and the equivalent loss power on main line was calculated. Branch line and distribution transformer were equivalent to a resistance located at the head of the line to match the real power consumption. With the data acquirement, accuracy can be improved. Finally, the example of different power supply zone was calculated based on the method. The comparison between the calculated results and technical guidelines of southern power grid indicated the components of the line loss and put forward solutions for loss reduction. The method proposed overcame disadvantage of strong dependence on complete and precise data, which fits for planning work.

  9. Characterization and Mitigation of Resistive Losses in a Large Area Laser Power Converter

    DTIC Science & Technology

    2014-03-27

    CHARACTERIZATION AND MITIGATION OF RESISTIVE LOSSES IN A LARGE AREA LASER POWER CONVERTER THESIS Eli A. Garduño, Second Lieutenant, USAF AFIT-ENP-14...LOSSES IN A LARGE AREA LASER POWER CONVERTER THESIS Presented to the Faculty Department of Engineering Physics Graduate School of Engineering and...DISTRIBUTION UNLIMITED. AFIT-ENP-14-M-09 CHARACTERIZATION AND MITIGATION OF RESISTIVE LOSSES IN A LARGE AREA LASER POWER CONVERTER Eli A. Garduño, BS

  10. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  11. Flux-transfer losses in helically wound superconducting power cables

    SciTech Connect

    Clem, John R; Malozemoff, A P

    2013-06-25

    Minimization of ac losses is essential for economic operation of high-temperature superconductor (HTS) ac power cables. A favorable configuration for the phase conductor of such cables has two counter-wound layers of HTS tape-shaped wires lying next to each other and helically wound around a flexible cylindrical former. However, if magnetic materials such as magnetic substrates of the tapes lie between the two layers, or if the winding pitch angles are not opposite and essentially equal in magnitude to each other, current distributes unequally between the two layers. Then, if at some point in the ac cycle the current of either of the two layers exceeds its critical current, a large ac loss arises from the transfer of flux between the two layers. A detailed review of the formalism, and its application to the case of paramagnetic substrates including the calculation of this flux-transfer loss, is presented.

  12. High frequency power distribution system

    NASA Technical Reports Server (NTRS)

    Patel, Mikund R.

    1986-01-01

    The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.

  13. Technology spin-off from space power automation to terrestrial electrical power distribution control and operation

    NASA Astrophysics Data System (ADS)

    Callis, C. T.; Broadwater, R. P.; Chandrasekaran, A.

    Areas which hold potential for technology spin-off from space power automation into terrestrial electrical power distribution control and automation are investigated. Areas touched upon include load management, loss reduction, trend analysis, energy storage, and fault diagnosis and analysis with expert systems. A brief overview of terrestrial electric power technology and automation in terrestrial distribution is provided. Power handling capabilities, hardware, loads, and goals of terrestrial and space systems are compared.

  14. Distributed Power Electronics for PV Systems (Presentation)

    SciTech Connect

    Deline, C.

    2011-12-01

    An overview of the benefits and applications of microinverters and DC power optimizers in residential systems. Some conclusions from this report are: (1) The impact of shade is greater than just the area of shade; (2) Additional mismatch losses include panel orientation, panel distribution, inverter voltage window, soiling; (3) Per-module devices can help increase performance, 4-12% or more depending on the system; (4) Value-added benefits (safety, monitoring, reduced design constraints) are helping their adoption; and (5) The residential market is growing rapidly. Efficiency increases, cost reductions are improving market acceptance. Panel integration will further reduce price and installation cost. Reliability remains an unknown.

  15. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect

    Chertkov, Michael; Turitsyn, Konstantin; Sulc, Petr; Backhaus, Scott

    2010-01-01

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  16. RFQ Designs and Beam-Loss Distributions for IFMIF

    SciTech Connect

    Jameson, Robert A

    2007-01-01

    The IFMIF 125 mA cw 40 MeV accelerators will set an intensity record. Minimization of particle loss along the accelerator is a top-level requirement and requires sophisticated design intimately relating the accelerated beam and the accelerator structure. Such design technique, based on the space-charge physics of linear accelerators (linacs), is used in this report in the development of conceptual designs for the Radio-Frequency-Quadrupole (RFQ) section of the IFMIF accelerators. Design comparisons are given for the IFMIF CDR Equipartitioned RFQ, a CDR Alternative RFQ, and new IFMIF Post-CDR Equipartitioned RFQ designs. Design strategies are illustrated for combining several desirable characteristics, prioritized as minimum beam loss at energies above ~ 1 MeV, low rf power, low peak field, short length, high percentage of accelerated particles. The CDR design has ~0.073% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7,is 12.3 m long, and accelerates ~89.6% of the input beam. A new Post-CDR design has ~0.077% losses above 1 MeV, requires ~1.1 MW rf structure power, has KP factor 1.7 and ~8 m length, and accelerates ~97% of the input beam. A complete background for the designs is given, and comparisons are made. Beam-loss distributions are used as input for nuclear physics simulations of radioactivity effects in the IFMIF accelerator hall, to give information for shielding, radiation safety and maintenance design. Beam-loss distributions resulting from a ~1M particle input distribution representative of the IFMIF ECR ion source are presented. The simulations reported were performed with a consistent family of codes. Relevant comparison with other codes has not been possible as their source code is not available. Certain differences have been noted but are not consistent over a broad range of designs and parameter range. The exact transmission found by any of these codes should be treated as indicative, as each has various sensitivities in

  17. Aggregate size distribution of the soil loss

    NASA Astrophysics Data System (ADS)

    Szabó, Judit Alexandra; Jakab, Gergely; Szabó, Boglárka; Józsa, Sándor; Szalai, Zoltán; Centeri, Csaba

    2016-04-01

    In agricultural areas the soil erosion and soil loss estimation is vital information in long-term planning. During the initial period of the erosion a part of the soil particles and aggregates get transportable and nutrients and organic matter could be transported due to the effect of water or wind. This preliminary phase was studied with laboratory-scale rainfall simulator. Developed surface crust and aggregate size composition of the runoff was examined in six different slope-roughness-moisture content combination of a Cambisol and a Regosol. The ratio of micro- and macro aggregates in the runoff indicate the stability of the aggregates and determine the transport capacity of the runoff. Both soil samples were taken from field where the water erosion is a potential hazard. During the experiment the whole amount of runoff and sediment was collected through sieve series to a bucket to separate the micro- and macro aggregates. In case of both samples the micro aggregates dominate in the runoff and the runoff rates are similar. Although the runoff of the Regosol - with dominant >1000μm macro aggregate content - contained almost nothing but <50μm sized micro aggregates. Meanwhile the runoff of the Cambisol - with more balanced micro and macro aggregate content - contained dominantly 50-250μm sized micro aggregates and in some case remarkable ratio 250-1000μm sized macro aggregates. This difference occurred because the samples are resistant against drop erosion differently. In case of both sample the selectivity of the erosion and substance matrix redistribution manifested in mineral crusts in the surface where the quartz deposited in place while the lighter organic matter transported with the sediment. The detachment of the aggregates and the redistribution of the particles highly effect on the aggregate composition of the runoff which is connected with the quality of the soil loss. So while the estimation of soil loss quantity is more or less is easy, measuring

  18. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  19. Loss distribution of systemic defaults in different interbank networks

    NASA Astrophysics Data System (ADS)

    Li, Shouwei; He, Jianmin

    2016-04-01

    We analyze the impact of the network structure, the default probability and the loss given default (LGD) on the loss distribution of systemic defaults in the interbank market, where network structures analyzed include random networks, small-world networks and scale-free networks. We find that the network structure has little effect on the shape of the loss distribution, whereas the opposite is true to the default probability; the LGD changes the shape of the loss distribution significantly when default probabilities are high; the maximum of the possible loss is sensitive to the network structure and the LGD.

  20. Voltage Regulation and Line Loss Minimization of Loop Distribution Systems Using UPFC

    NASA Astrophysics Data System (ADS)

    Sayed, Mahmoud A.; Takeshita, Takaharu

    This paper presents a new method for achieving line loss minimization and voltage regulation in the loop distribution systems, simultaneously. First, mathematical analysis of the line loss minimum conditions in the loop distribution systems is presented. Then, load voltage regulation is applied in the loop distribution system under line loss minimum condition. Reference angle of the desired load voltage is the main factor that can be used to minimize total line loss during load voltage control. In order to achieve these two objectives simultaneously, the UPFC (unified power flow controller), a typical FACTS (flexible AC transmission systems) device, that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the UPFC control scheme to regulate the load voltage under line loss minimization is presented. The effectiveness of the proposed control scheme has been verified experimentally using laboratory prototype in a 200V, 6kVA system.

  1. Fundamental rate-loss tradeoff for optical quantum key distribution

    NASA Astrophysics Data System (ADS)

    Takeoka, Masahiro; Guha, Saikat; Wilde, Mark M.

    2014-10-01

    Since 1984, various optical quantum key distribution (QKD) protocols have been proposed and examined. In all of them, the rate of secret key generation decays exponentially with distance. A natural and fundamental question is then whether there are yet-to-be discovered optical QKD protocols (without quantum repeaters) that could circumvent this rate-distance tradeoff. This paper provides a major step towards answering this question. Here we show that the secret key agreement capacity of a lossy and noisy optical channel assisted by unlimited two-way public classical communication is limited by an upper bound that is solely a function of the channel loss, regardless of how much optical power the protocol may use. Our result has major implications for understanding the secret key agreement capacity of optical channels—a long-standing open problem in optical quantum information theory—and strongly suggests a real need for quantum repeaters to perform QKD at high rates over long distances.

  2. Mobile Centers For Secondary Power Distribution

    NASA Technical Reports Server (NTRS)

    Mears, Robert L.

    1990-01-01

    Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

  3. Convective contributions to local power loss in a Bumpy Torus

    SciTech Connect

    Hiroe, S.; Haste, G.R. Jr.; Tolliver, J.S.; Quon, B.H.; Goyer, J.R.; Solensten, L.; Conner, K.A.

    1986-12-01

    Power flow in the ELMO Bumpy Torus (Plasma Physics and Controlled Nuclear Fusion Research (Tokyo, 1974) (IAEA, Vienna, 1975) Vol. 2, p. 141; Plasma Phys. 25, 597 (1983)) was investigated by measuring the power received by a limiter. Selective removal of heating power from various cavities, including the cavity with the limiter, has demonstrated that the majority of the power is lost locally. Observations of the potential structure demonstrate that asymmetric potential contours are present which can lead to enhanced plasma loss.

  4. Space Station Freedom power management and distribution design status

    NASA Technical Reports Server (NTRS)

    Javidi, S.; Gholdston, E.; Stroh, P.

    1989-01-01

    The design status of the power management and distribution electric power system for the Space Station Freedom is presented. The current design is a star architecture, which has been found to be the best approach for meeting the requirement to deliver 120 V dc to the user interface. The architecture minimizes mass and power losses while improving element-to-element isolation and system flexibility. The design is partitioned into three elements: energy collection, storage and conversion, system protection and distribution, and management and control.

  5. Solar power generation and distribution

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The production of electricity from solar energy is discussed. The economics of the proposed generation and distribution systems are analyzed. The use of photovoltaics for converting solar energy to home heating is proposed. The problems of energy distribution are analyzed from the standpoint of equipment costs and complexity.

  6. Distributed photovoltaic generation in residential distribution systems: Impacts on power quality and anti-islanding

    NASA Astrophysics Data System (ADS)

    Mitra, Parag

    The past few decades have seen a consistent growth of distributed PV sources. Distributed PV, like other DG sources, can be located at or near load centers and provide benefits which traditional generation may lack. However, distribution systems were not designed to accommodate such power generation sources as these sources might lead to operational as well as power quality issues. A high penetration of distributed PV resources may lead to bi-directional power flow resulting in voltage swells, increased losses and overloading of conductors. Voltage unbalance is a concern in distribution systems and the effect of single-phase residential PV systems on voltage unbalance needs to be explored. Furthermore, the islanding of DGs presents a technical hurdle towards the seamless integration of DG sources with the electricity grid. The work done in this thesis explores two important aspects of grid inte-gration of distributed PV generation, namely, the impact on power quality and anti-islanding. A test distribution system, representing a realistic distribution feeder in Arizona is modeled to study both the aforementioned aspects. The im-pact of distributed PV on voltage profile, voltage unbalance and distribution sys-tem primary losses are studied using CYMDIST. Furthermore, a PSCAD model of the inverter with anti-island controls is developed and the efficacy of the anti-islanding techniques is studied. Based on the simulations, generalized conclusions are drawn and the problems/benefits are elucidated.

  7. Distribution-Agnostic Stochastic Optimal Power Flow for Distribution Grids

    SciTech Connect

    Baker, Kyri; Dall'Anese, Emiliano; Summers, Tyler

    2016-11-21

    This paper outlines a data-driven, distributionally robust approach to solve chance-constrained AC optimal power flow problems in distribution networks. Uncertain forecasts for loads and power generated by photovoltaic (PV) systems are considered, with the goal of minimizing PV curtailment while meeting power flow and voltage regulation constraints. A data- driven approach is utilized to develop a distributionally robust conservative convex approximation of the chance-constraints; particularly, the mean and covariance matrix of the forecast errors are updated online, and leveraged to enforce voltage regulation with predetermined probability via Chebyshev-based bounds. By combining an accurate linear approximation of the AC power flow equations with the distributionally robust chance constraint reformulation, the resulting optimization problem becomes convex and computationally tractable.

  8. Computer Power: Part 1: Distribution of Power (and Communications).

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1988-01-01

    Discussion of the distribution of power to personal computers and computer terminals addresses options such as extension cords, perimeter raceways, and interior raceways. Sidebars explain: (1) the National Electrical Code; (2) volts, amps, and watts; (3) transformers, circuit breakers, and circuits; and (4) power vs. data wiring. (MES)

  9. Forecasting photovoltaic array power production subject to mismatch losses

    SciTech Connect

    Picault, D.; Raison, B.; Bacha, S.; de la Casa, J.; Aguilera, J.

    2010-07-15

    The development of photovoltaic (PV) energy throughout the world this last decade has brought to light the presence of module mismatch losses in most PV applications. Such power losses, mainly occasioned by partial shading of arrays and differences in PV modules, can be reduced by changing module interconnections of a solar array. This paper presents a novel method to forecast existing PV array production in diverse environmental conditions. In this approach, field measurement data is used to identify module parameters once and for all. The proposed method simulates PV arrays with adaptable module interconnection schemes in order to reduce mismatch losses. The model has been validated by experimental results taken on a 2.2 kW{sub p} plant, with three different interconnection schemes, which show reliable power production forecast precision in both partially shaded and normal operating conditions. Field measurements show interest in using alternative plant configurations in PV systems for decreasing module mismatch losses. (author)

  10. On loss distributions from installment-repaid loans.

    PubMed

    Crowder, Martin; Hand, David J

    2005-12-01

    The banks have been accumulating huge data bases for many years and are increasingly turning to statistics to provide insight into customer behaviour, among other things. Credit risk is an important issue and certain stochastic models have been developed in recent years to describe and predict loan default. Two of the major models currently used in the industry are considered here, and various ways of extending their application to the case where a loan is repaid in installments are explored. The aspect of interest is the probability distribution of the total loss due to repayment default at some time. Thus, the loss distribution is determined by the distribution of times to default, here regarded as a discrete-time survival distribution. In particular, the probabilities of large losses are to be assessed for insurance purposes.

  11. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, Richard F.

    1998-01-01

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in U.S. Patent No. 5,495,221 entitled "Dynamically Stable Magnetic Suspension/Bearing System." The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity.

  12. Passive magnetic bearing element with minimal power losses

    DOEpatents

    Post, R.F.

    1998-12-08

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in US Patent No. 5,495,221 entitled ``Dynamically Stable Magnetic Suspension/Bearing System.`` The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity. 8 figs.

  13. Assessment of distributed wind-power systems. Final report

    SciTech Connect

    Kaupang, B.M.

    1983-02-01

    A utility-oriented methodology for the purpose of evaluating distributed wind-power systems was developed and tested, utilizing data from three actual utility systems. Conventional utility planning techniques were used, including loss-of-load probability and production-cost-simulation methods in the generation planning area, transmission and distribution (T and D) system expansion models, and loss calculations. Evaluations were based on comparison of total utility-system cost with an without wind-power plants, and wre expressed in terms of wind-power-plant value and cost. Value is measured by the worth of displaced energy and capacity of conventional power plants, of T and D equipmen deferrals, and of T and D loss savings. Cost consists of he capital, and operating and maintenace costs of the wind-power plants. The value of distributed wind-power generation was found to be dominated by the generation energy and capacity value, as opposed to T and D system impacts. The energy value alone did, in two of the three utilities studied, result in a favorable value/cost relationship for the cost assumptions that were used. The problem of voltage fluctuation on distribution feeders from wind turbines due to wind gusts was studied for several sites. In most relaistic applications, the voltage fluctuations would not be a limiting criterion for practical wind-turbine penetration levels. If the wind turbine is connected to the distributionfeeder through a rectifier-inverter, voltage fluctuations become a negligible factor. However, reactive-power compensation of the inverter would most likely be required for this application.

  14. Space Solar Power Management and Distribution (PMAD)

    NASA Technical Reports Server (NTRS)

    Lynch, Thomas H.

    2000-01-01

    This paper presents, in viewgraph form, SSP PMAD (Space Solar Power Management and Distribution). The topics include: 1) Architecture; 2) Backside Thermal View; 3) Solar Array Interface; 4) Transformer design and risks; 5) Twelve phase rectifier; 6) Antenna (80V) Converters; 7) Distribution Cables; 8) Weight Analysis; and 9) PMAD Summary.

  15. Cathode power distribution system and method of using the same for power distribution

    DOEpatents

    Williamson, Mark A; Wiedmeyer, Stanley G; Koehl, Eugene R; Bailey, James L; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2014-11-11

    Embodiments include a cathode power distribution system and/or method of using the same for power distribution. The cathode power distribution system includes a plurality of cathode assemblies. Each cathode assembly of the plurality of cathode assemblies includes a plurality of cathode rods. The system also includes a plurality of bus bars configured to distribute current to each of the plurality of cathode assemblies. The plurality of bus bars include a first bus bar configured to distribute the current to first ends of the plurality of cathode assemblies and a second bus bar configured to distribute the current to second ends of the plurality of cathode assemblies.

  16. Intelligent Systems for Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Button, Robert M.

    2002-01-01

    The motivation behind an advanced technology program to develop intelligent power management and distribution (PMAD) systems is described. The program concentrates on developing digital control and distributed processing algorithms for PMAD components and systems to improve their size, weight, efficiency, and reliability. Specific areas of research in developing intelligent DC-DC converters and distributed switchgear are described. Results from recent development efforts are presented along with expected future benefits to the overall PMAD system performance.

  17. Hierarchical distributed stabilization of power networks

    NASA Astrophysics Data System (ADS)

    Ishizaki, Takayuki; Sadamoto, Tomonori; Imura, Jun-ichi

    2014-10-01

    Large fluctuation of electric power due to high penetration of renewable energy sources such as photovoltaic and wind power generation increases the risk to make the whole power network system unstable. The conventional frequency control called load frequency control is based on PID (proportional-integral-derivative) control or more advanced centralized and decentralized/distributed control. If we could more effectively use information on the state of the other neighbor generators, we can expect to make the whole system more robust against the large frequency fluctuation. This paper proposes a fundamental framework towards the design of hierarchical distributed stabilizing controllers for a network of power generators and loads. This novel type of distributed controller, composed of a global controller and a set of local controllers, takes into account the effect of the interaction among the generators and loads to improve robustness for the variation of locally stabilizing controllers.

  18. Study of the longitudinal distribution of power generated in a random distributed feedback Raman fibre laser with unidirectional pumping

    SciTech Connect

    Churkin, D V; El-Taher, A E; Vatnik, I D; Babin, Sergei A

    2012-09-30

    The longitudinal distribution of the Stokes-component power in a Raman fibre laser with a random distributed feedback and unidirectional pumping is measured. The fibre parameters (linear loss and Rayleigh backscattering coefficient) are calculated based on the distributions obtained. A numerical model is developed to describe the lasing power distribution. The simulation results are in good agreement with the experimental data. (optical fibres, lasers and amplifiers. properties and applications)

  19. Grid-connected distributed solar power systems

    NASA Astrophysics Data System (ADS)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  20. Vibration Monitoring of Power Distribution Poles

    SciTech Connect

    Clark Scott; Gail Heath; John Svoboda

    2006-04-01

    Some of the most visible and least monitored elements of our national security infrastructure are the poles and towers used for the distribution of our nation’s electrical power. Issues surrounding these elements within the United States include safety such as unauthorized climbing and access, vandalism such as nut/bolt removal or destructive small arms fire, and major vandalism such as the downing of power poles and towers by the cutting of the poles with a chainsaw or torches. The Idaho National Laboratory (INL) has an ongoing research program working to develop inexpensive and sensitive sensor platforms for the monitoring and characterization of damage to the power distribution infrastructure. This presentation covers the results from the instrumentation of a variety of power poles and wires with geophone assemblies and the recording of vibration data when power poles were subjected to a variety of stimuli. Initial results indicate that, for the majority of attacks against power poles, the resulting signal can be seen not only on the targeted pole but on sensors several poles away in the distribution network and a distributed sensor system can be used to monitor remote and critical structures.

  1. Power loss in electrical steel under elliptically rotating flux conditions

    SciTech Connect

    Salz, W.; Hempel, K.A.

    1996-03-01

    The power loss of electrical steel sheet given in the data sheets of the steel manufacturers is related to linearly alternating flux conditions, measured with an Epstein frame or a single sheet tester, respectively. In the application of the material in electrical machines, the authors find large areas with rotational flux conditions, i.e., in the T-joint region of three-phase power transformers or above the stator teeth of three-phase motors and generators. The most general description of the magnetization process in this case is an elliptically rotating flux. The paper outlines the magnetic behavior of steel sheet under these flux conditions, and finally defines a simple method to predict the total power loss under elliptically rotating flux from data measured under linearly alternating and circularly rotating flux conditions only.

  2. Inverter design for high frequency power distribution

    NASA Technical Reports Server (NTRS)

    King, R. J.

    1985-01-01

    A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.

  3. Galileo spacecraft power management and distribution system

    NASA Technical Reports Server (NTRS)

    Detwiler, R. C.; Smith, R. L.

    1990-01-01

    The Galileo PMAD (power management and distribution system) is described, and the design drivers that established the final as-built hardware are discussed. The spacecraft is powered by two general-purpose heat-source-radioisotope thermoelectric generators. Power bus regulation is provided by a shunt regulator. Galileo PMAD distributes a 570-W beginning of mission (BOM) power source to a user complement of some 137 load elements. Extensive use of pyrotechnics requires two pyro switching subassemblies. They initiate 148 squibs which operate the 47 pyro devices on the spacecraft. Detection and correction of faults in the Galileo PMAD is an autonomous feature dictated by requirements for long life and reliability in the absence of ground-based support. Volatile computer memories in the spacecraft command and data system and attitude control system require a continuous source of backup power during all anticipated power bus fault scenarios. Power for the Jupiter Probe is conditioned, isolated, and controlled by a Probe interface subassembly. Flight performance of the spacecraft and the PMAD has been successful to date, with no major anomalies.

  4. Tailoring the energy distribution and loss of 2D plasmons

    NASA Astrophysics Data System (ADS)

    Lin, Xiao; Rivera, Nicholas; López, Josué J.; Kaminer, Ido; Chen, Hongsheng; Soljačić, Marin

    2016-10-01

    The ability to tailor the energy distribution of plasmons at the nanoscale has many applications in nanophotonics, such as designing plasmon lasers, spasers, and quantum emitters. To this end, we analytically study the energy distribution and the proper field quantization of 2D plasmons with specific examples for graphene plasmons. We find that the portion of the plasmon energy contained inside graphene (energy confinement factor) can exceed 50%, despite graphene being infinitely thin. In fact, this very high energy confinement can make it challenging to tailor the energy distribution of graphene plasmons just by modifying the surrounding dielectric environment or the geometry, such as changing the separation distance between two coupled graphene layers. However, by adopting concepts of parity-time symmetry breaking, we show that tuning the loss in one of the two coupled graphene layers can simultaneously tailor the energy confinement factor and propagation characteristics, causing the phenomenon of loss-induced plasmonic transparency.

  5. Helicopter optimal descent and landing after power loss

    NASA Technical Reports Server (NTRS)

    Johnson, W.

    1977-01-01

    An optimal control solution is obtained for the descent and landing of a helicopter after the loss of power in level flight. The model considers the helicopter vertical velocity, horizontal velocity, and rotor speed; and it includes representations of ground effect, rotor inflow time lag, pilot reaction time, rotor stall, and the induced velocity curve in the vortex ring state. The control (rotor thrust magnitude and direction) required to minimize the vertical and horizontal velocity at contact with the ground is obtained using nonlinear optimal control theory. It is found that the optimal descent after power loss in hover is a purely vertical flight path. Good correlation, even quantitatively, is found between the calculations and (non-optimal) flight test results.

  6. Power Management and Distribution System Developed for Thermionic Power Converters

    NASA Technical Reports Server (NTRS)

    Baez, Anastacio N.

    1998-01-01

    A spacecraft solar, bimodal system combines propulsion and power generation into a single integrated system. An Integrated Solar Upper Stage (ISUS) provides orbital transfer capabilities, power generation for payloads, and onboard propulsion to the spacecraft. A key benefit of a bimodal system is a greater payload-to-spacecraft mass ratio resulting in lower launch vehicle requirements. Scaling down to smaller launch vehicles increases space access by reducing overall mission cost. NASA has joined efforts with the Air Force Phillips Laboratory to develop enabling technologies for such a system. The NASA/Air Force bimodal concept uses solar concentrators to focus energy into an integrated power plant. This power plant consists of a graphite core that stores thermal energy within a cavity. An array of thermionic converters encircles the graphite cavity and provides electrical energy conversion functions. During the power generation phase of the bimodal system, the thermionic converters are exposed to the heated cavity and convert the thermal energy to electricity. Near-term efforts of the ISUS bimodal program are focused on a ground demonstration of key technologies in order to proceed to a full space flight test. Thermionic power generation is one key technology of the bimodal concept. Thermionic power converters impose unique operating requirements upon a power management and distribution (PMAD) system design. Single thermionic converters supply large currents at very low voltages. Operating voltages can vary over a range of up to 3 to 1 as a function of operating temperature. Most spacecraft loads require regulated 28-volts direct-current (Vdc) power. A combination of series-connected converters and powerprocessing boosters is required to deliver power to the spacecraft's payloads at this level.

  7. Lower hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.; Brunner, D.; LaBombard, B.; Parker, R. R.; Terry, J. L.; Whyte, D. G.; Baek, S. G.; Edlund, E.; Hubbard, A. E.; Hughes, J. W.; Kuang, A. Q.; Reinke, M. L.; Shiraiwa, S.; Wallace, G. M.; Walk, J. R.

    2016-05-01

    For the first time, the power deposition of lower hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal, and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt ( t < τ E ) response of the scrape-off-layer (SOL) plasma to Lower Hybrid Radiofrequency (LHRF) power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be a key for the LHRF edge power deposition physics. These observations support the existence of a loss mechanism near the edge for LHRF at high density ( n e > 1.0 × 10 20 (m-3)). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivate the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch.

  8. Influence of the UV-induced fiber loss on the distributed feedback fiber lasers

    NASA Astrophysics Data System (ADS)

    Fan, Wei; Chen, Bai; Qiao, Qiquan; Chen, Jialing; Lin, Zunqi

    2003-06-01

    It was found that the output power of the distributed feedback fiber lasers would be improved after annealing or left unused for several days after the laser had been fabricated, and the output of the fundamental mode would not increase but be clamped while the ±1 order modes would be predominant with the enhancement of the coupling coefficient during the fabrication. The paper discussed the influence of UV-induced fiber loss on the fiber phase-shifted DFB lasers. Due to the gain saturation and fiber internal loss, which included the temperament loss and permanent loss, there was an optimum coupling coefficient for the DFB fiber lasers that the higher internal fiber loss corresponded to the lower optimum values of coupling coefficient.

  9. Lowland tapir distribution and habitat loss in South America.

    PubMed

    Cordeiro, Jose Luis Passos; Fragoso, José M V; Crawshaw, Danielle; Oliveira, Luiz Flamarion B

    2016-01-01

    The development of species distribution models (SDMs) can help conservation efforts by generating potential distributions and identifying areas of high environmental suitability for protection. Our study presents a distribution and habitat map for lowland tapir in South America. We also describe the potential habitat suitability of various geographical regions and habitat loss, inside and outside of protected areas network. Two different SDM approaches, MAXENT and ENFA, produced relative different Habitat Suitability Maps for the lowland tapir. While MAXENT was efficient at identifying areas as suitable or unsuitable, it was less efficient (when compared to the results by ENFA) at identifying the gradient of habitat suitability. MAXENT is a more multifaceted technique that establishes more complex relationships between dependent and independent variables. Our results demonstrate that for at least one species, the lowland tapir, the use of a simple consensual approach (average of ENFA and MAXENT models outputs) better reflected its current distribution patterns. The Brazilian ecoregions have the highest habitat loss for the tapir. Cerrado and Atlantic Forest account for nearly half (48.19%) of the total area lost. The Amazon region contains the largest area under protection, and the most extensive remaining habitat for the tapir, but also showed high levels of habitat loss outside protected areas, which increases the importance of support for proper management.

  10. Lowland tapir distribution and habitat loss in South America

    PubMed Central

    Fragoso, José M.V.; Crawshaw, Danielle; Oliveira, Luiz Flamarion B.

    2016-01-01

    The development of species distribution models (SDMs) can help conservation efforts by generating potential distributions and identifying areas of high environmental suitability for protection. Our study presents a distribution and habitat map for lowland tapir in South America. We also describe the potential habitat suitability of various geographical regions and habitat loss, inside and outside of protected areas network. Two different SDM approaches, MAXENT and ENFA, produced relative different Habitat Suitability Maps for the lowland tapir. While MAXENT was efficient at identifying areas as suitable or unsuitable, it was less efficient (when compared to the results by ENFA) at identifying the gradient of habitat suitability. MAXENT is a more multifaceted technique that establishes more complex relationships between dependent and independent variables. Our results demonstrate that for at least one species, the lowland tapir, the use of a simple consensual approach (average of ENFA and MAXENT models outputs) better reflected its current distribution patterns. The Brazilian ecoregions have the highest habitat loss for the tapir. Cerrado and Atlantic Forest account for nearly half (48.19%) of the total area lost. The Amazon region contains the largest area under protection, and the most extensive remaining habitat for the tapir, but also showed high levels of habitat loss outside protected areas, which increases the importance of support for proper management. PMID:27672509

  11. Simulation Study of Gyrotron Traveling Wave Amplifier with Distributed-Loss in Facilities for Aquaculture

    NASA Astrophysics Data System (ADS)

    Hua, Xufeng; Chen, Chengxun; Xu, Dawei; Xing, Kezhi

    In this paper, we introduce a W-band gyro-traveling wave (gyro-TWT) tube to suppress spurious oscillations, which is used in facilities for Aquaculture. The spurious oscillations block achieving high gain and high power in high-power broadband millimeter amplifier. In order to suppress spurious oscillations, we study the interaction circuit including input coupler and output section, design the gyro-traveling wave tube with distributed-loss based on MIG. The results of simulation show that high power and broad-band capabilities.

  12. Improved method for loss minimization in distribution networks

    SciTech Connect

    Borozan, V.; Rajicic, D.; Ackovski, R.

    1995-08-01

    A heuristic method for determining the distribution network configuration with minimum resistive line losses is described. This method is based on optimality condition developed by Merlin and Back. Using a fast and reliable load flow solution technique and introducing efficient algorithms for network elements inspection, that methodology becomes suitable for a real-time application. The proposed method is tested on a three test-systems, used in literature for the same purposes. Its efficiency advantages are especially emphasized in its application on distribution networks of realistic size.

  13. Uncertainty evaluation in BEACON power distribution monitoring

    SciTech Connect

    Morita, T.; Goldstein, N.P. )

    1989-11-01

    BEACON is an advanced operational core support package that has a three-dimensional nodal code as its cornerstone. The three-dimensional calculation includes all necessary pressurized water reactor feedback effects. The generation of the measured power distribution from the core instrumentation is one of the primary functions of the core-monitoring software. The purpose of this paper is to discuss evaluation of the uncertainty in the measured assembly power from the BEACON system. The study covers not only the normal operating conditions, but off-normal situations to demonstrate BEACON's applicability for that condition.

  14. Distributed Wireless Power Transfer With Energy Feedback

    NASA Astrophysics Data System (ADS)

    Lee, Seunghyun; Zhang, Rui

    2017-04-01

    Energy beamforming (EB) is a key technique for achieving efficient radio-frequency (RF) transmission enabled wireless energy transfer (WET). By optimally designing the waveforms from multiple energy transmitters (ETs) over the wireless channels, they can be constructively combined at the energy receiver (ER) to achieve an EB gain that scales with the number of ETs. However, the optimal design of EB waveforms requires accurate channel state information (CSI) at the ETs, which is challenging to obtain practically, especially in a distributed system with ETs at separate locations. In this paper, we study practical and efficient channel training methods to achieve optimal EB in a distributed WET system. We propose two protocols with and without centralized coordination, respectively, where distributed ETs either sequentially or in parallel adapt their transmit phases based on a low-complexity energy feedback from the ER. The energy feedback only depends on the received power level at the ER, where each feedback indicates one particular transmit phase that results in the maximum harvested power over a set of previously used phases. Simulation results show that the two proposed training protocols converge very fast in practical WET systems even with a large number of distributed ETs, while the protocol with sequential ET phase adaptation is also analytically shown to converge to the optimal EB design with perfect CSI by increasing the training time. Numerical results are also provided to evaluate the performance of the proposed distributed EB and training designs as compared to other benchmark schemes.

  15. Global wetlands: Potential distribution, wetland loss, and status.

    PubMed

    Hu, Shengjie; Niu, Zhenguo; Chen, Yanfen; Li, Lifeng; Zhang, Haiying

    2017-05-15

    Even though researchers have paid a great deal of attention to wetland loss and status, the actual extent of wetland loss on a global scale, especially the loss caused directly by human activities, and the actual extent of currently surviving wetlands remains uncertain. This paper simulated the potential distribution of global wetlands by employing a new Precipitation Topographic Wetness Index (PTWI) and global remote sensing training samples. The results show earth would have approximately 29.83millionkm(2) of wetlands, if humans did not interfere with wetland ecosystems. By combining datasets related to global wetlands, we found that at least 33% of global wetlands had been lost as of 2009, including 4.58millionkm(2) of non-water wetlands and 2.64millionkm(2) of open water. The areal extent of wetland loss has been greatest in Asia, but Europe has experienced the most serious losses. Wetland-related datasets suffer from major inconsistencies, and estimates of the areal extent of the remaining global wetlands ranged from 1.53 to 14.86millionkm(2). Therefore, although it is challenging, thematic mapping of global wetlands is necessary and urgently needed.

  16. Relativity, nonextensivity, and extended power law distributions.

    PubMed

    Silva, R; Lima, J A S

    2005-11-01

    A proof of the relativistic theorem by including nonextensive effects is given. As it happens in the nonrelativistic limit, the molecular chaos hypothesis advanced by Boltzmann does not remain valid, and the second law of thermodynamics combined with a duality transformation implies that the parameter lies on the interval [0,2]. It is also proven that the collisional equilibrium states (null entropy source term) are described by the relativistic power law extension of the exponential Juttner distribution which reduces, in the nonrelativistic domain, to the Tsallis power law function. As a simple illustration of the basic approach, we derive the relativistic nonextensive equilibrium distribution for a dilute charged gas under the action of an electromagnetic field . Such results reduce to the standard ones in the extensive limit, thereby showing that the nonextensive entropic framework can be harmonized with the space-time ideas contained in the special relativity theory.

  17. Ice Accretion Prediction on Wind Turbines and Consequent Power Losses

    NASA Astrophysics Data System (ADS)

    Yirtici, Ozcan; Tuncer, Ismail H.; Ozgen, Serkan

    2016-09-01

    Ice accretion on wind turbine blades modifies the sectional profiles and causes alteration in the aerodynamic characteristic of the blades. The objective of this study is to determine performance losses on wind turbines due to the formation of ice in cold climate regions and mountainous areas where wind energy resources are found. In this study, the Blade Element Momentum method is employed together with an ice accretion prediction tool in order to estimate the ice build-up on wind turbine blades and the energy production for iced and clean blades. The predicted ice shapes of the various airfoil profiles are validated with the experimental data and it is shown that the tool developed is promising to be used in the prediction of power production losses of wind turbines.

  18. Reflectance loss of prospective solar concentrator mirrors in erosive environments. The Crosbyton Solar Power Project

    SciTech Connect

    Bethea, R.M.; Barringer, M.T.; Chin, S.; Collier, E.G.; Cooper, A.M.; Reichert, J.D. Jr.; Williams, P.F.

    1986-01-01

    The problem addressed in this phase of the Crosbyton Solar Power Project was that of the effect of weathering of solar concentrator mirrors proposed for use in the fixed-mirror, distributed-focus (solar bowl) system with particular emphasis on erosion due to exposure during dust storms. The specific objectives of this research were to evaluate the mirrors with respect to initial reflectance, loss of reflectance due to dust storms and other outdoor exposure phenomena, and dimensional stability; and to develop a rapid technique for the simulation of dust storms so that a model for such reflectance loss as a function of exposure could be developed.

  19. Effect of the electron energy distribution on total energy loss with argon in inductively coupled plasmas

    SciTech Connect

    Kim, June Young; Kim, Young-Cheol; Kim, Yu-Sin; Chung, Chin-Wook

    2015-01-15

    The total energy lost per electron-ion pair lost ε{sub T} is investigated with the electron energy distribution function (EEDF). The EEDFs are measured at various argon powers in RF inductively coupled plasma, and the EEDFs show a depleted distribution (a discontinuity occurring at the minimum argon excitation threshold energy level) with the bulk temperature and the tail temperature. The total energy loss per electron-ion pair lost ε{sub T} is calculated from a power balance model with the Maxwellian EEDFs and the depleted EEDFs and then compared with the measured ε{sub T} from the floating probe. It is concluded that the small population of the depleted high energy electrons dramatically increases the collisional energy loss, and the calculated ε{sub T} from the depleted EEDFs has a value that is similar to the measured ε{sub T}.

  20. Electrical power systems for distributed generation

    SciTech Connect

    Robertson, T.A.; Huval, S.J.

    1996-12-31

    {open_quotes}Distributed Generation{close_quotes} has become the {open_quotes}buzz{close_quotes} word of an electric utility industry facing deregulation. Many industrial facilities utilize equipment in distributed installations to serve the needs of a thermal host through the capture of exhaust energy in a heat recovery steam generator. The electrical power generated is then sold as a {open_quotes}side benefit{close_quotes} to the cost-effective supply of high quality thermal energy. Distributed generation is desirable for many different reasons, each with unique characteristics of the product. Many years of experience in the distributed generation market has helped Stewart & Stevenson to define a range of product features that are crucial to most any application. The following paper will highlight a few of these applications. The paper will also examine the range of products currently available and in development. Finally, we will survey the additional services offered by Stewart & Stevenson to meet the needs of a rapidly changing power generation industry.

  1. Stable harmonic multiplying gyrotron traveling-wave amplifier with distributed wall losses and attenuating severs

    SciTech Connect

    Yeh, Y. S.; Cheng, J. H.; Chen, L. K.; Hung, C. W.; Lo, C. Y.; Liao, C. W.

    2008-02-15

    Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWTs) provide magnetic field reduction and frequency multiplication. However, spurious oscillations may reduce the amplification of the gyro-TWT. Most distributed-loss structures are stabilized in gyro-TWTs that operate at low beam currents. Attenuating severs are added to the interaction circuit of a distributed-loss gyro-TWT to prevent high beam currents that result in mode competition. This study proposes a Ka-band harmonic multiplying gyro-TWT, using distributed wall losses and attenuating severs, to improve the stability of the amplification and the performance of the amplifier. Simulation results reveal that the absolute instabilities are effectively suppressed by wall losses of the lossy and severed sections, especially in the low-k{sub z} and high-order modes. Meanwhile, the severed section, dividing an interaction circuit into several short sections, reduces the effective interaction lengths of the absolute instabilities. The stable harmonic multiplying gyro-TWT is predicted to yield a peak output power of 230 kW at 33.65 GHz with an efficiency of 30%, a saturated gain of 40 dB, and a 3 dB bandwidth of 0.8 GHz for a 60 kV, 13 A electron beam with an axial velocity spread of {delta}v{sub z}/v{sub z}=8%. The power/gain scaling and phase relation between the drive and the output waves are elucidated.

  2. Evaluation of Loss of Offsite Power Events at Nuclear Power Plants: 1980 - 1996

    SciTech Connect

    C. L. Atwood; D. A. Prawdzik; D. L. Kelly; F. M. Marshall; J. W. Stetkar

    1999-08-01

    It is recognized that the availability of AC power to commercial nuclear power plants is essential for safe operations and accident recovery. A loss of offsite power (LOSP) event, therefore, is considered an important contributor to total risk at nuclear power plants. In 1988, the U. S. Nuclear Regulatory Commission published NUREG-1032 to report on an evaluation of the risk from actual LOSP events that had occurred at nuclear power plants within the United States up through 1985. This paper summarizes a similar study, whose primary objective was to update the LOSP model parameters, frequency and recovery time, using power plant event data from 1980-1996, published as NUREG/CR-5496 in 1998. An additional objective of the study is to re-examine the engineering insights concerning LOSP events.

  3. Healthcare Assistants: distributional losses as a consequence of NHS modernisation?

    PubMed Central

    Clark, Ian; Thompson, Amanda

    2015-01-01

    This paper examines the labour process of Healthcare Assistants (HCAs) at a National Health Service (NHS) hospital trust (TUH) in the context of the NHS modernisation agenda. It determines whether application of the modernisation agenda is formalised at TUH and considers how HCAs are affected. The paper is based upon 60 interviews with HCAs, structured questionnaires completed by all interview respondents, observation of HCAs and interviews with non‐clinical managers. The findings show that elements of the modernisation agenda are informally implemented at TUH to the detriment of HCAs. HCAs experience distributional losses in the form of intensification as nurses deflect duties to HCAs and insulate themselves from adverse effects. HCAs resist, using selective absence when pressures mount. They ameliorate losses by re‐internalising their work as a job with caring elements not a genuine caring role. They rationalise their altered behaviour towards patients by blaming the regime's treatment of them as a subordinated group. PMID:27570359

  4. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    NASA Astrophysics Data System (ADS)

    Leung, Ho Yan; Budgett, David M.; Taberner, Andrew; Hu, Patrick

    2014-09-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter.

  5. Microwave Driven Actuators Power Allocation and Distribution

    NASA Technical Reports Server (NTRS)

    Forbes, Timothy; Song, Kyo D.

    2000-01-01

    Design, fabrication and test of a power allocation and distribution (PAD) network for microwave driven actuators is presented in this paper. Development of a circuit that would collect power from a rectenna array amplify and distribute the power to actuators was designed and fabricated for space application in an actuator array driven by a microwave. A P-SPICE model was constructed initially for data reduction purposes, and was followed by a working real-world model. A voltage up - converter (VUC) is used to amplify the voltage from the individual rectenna. The testing yielded a 26:1 voltage amplification ratio with input voltage at 9 volts and a measured output voltage 230VDC. Future work includes the miniaturization of the circuitry, the use of microwave remote control, and voltage amplification technology for each voltage source. The objective of this work is to develop a model system that will collect DC voltage from an array of rectenna and propagate the voltage to an array of actuators.

  6. Power system operations: State estimation distributed processing

    NASA Astrophysics Data System (ADS)

    Ebrahimian, Mohammad Reza

    We present an application of a robust and fast parallel algorithm to power system state estimation with minimal amount of modifications to existing state estimators presently in place using the Auxiliary Problem Principle. We demonstrate its effectiveness on IEEE test systems, the Electric Reliability Counsel of Texas (ERCOT), and the Southwest Power Pool (SPP) systems. Since state estimation formulation may lead to an ill-conditioned system, we provide analytical explanations of the effects of mixtures of measurements on the condition of the state estimation information matrix. We demonstrate the closeness of the analytical equations to condition of several test case systems including IEEE RTS-96 and IEEE 118 bus systems. The research on the condition of the state estimation problem covers the centralized as well as distributed state estimation.

  7. Noise analysis in power distribution systems

    NASA Astrophysics Data System (ADS)

    Danisor, Alin

    2016-12-01

    This paper proposes an analysis, especially in time domain, of the electrical noise existent on the power distribution lines. This study is important for the use of powerlines as a channel of information transmissions. This information may refer to analog signals and as well to digital signals. The main problem addressed in this paper consists in the characterization of the background noise and to establish his statistical proprieties. It is very important to know if the noise induced in the transmission channel is a stationary one, or even an ergodic one. The main parameters like the mean value, the mean square value were determined in this paper. The approximation of the probability density function of each statistical parameter was studied. The pulses induced in the transmission channel by the transient phenomena of the power electrical systems were considered deterministic signals and their contributions were not included in this study.

  8. Interaction of lightning with power distribution lines

    NASA Astrophysics Data System (ADS)

    Mata, Carlos Tomas

    Triggered-lightning experiments were conducted in 1996, 1999, and 2000 to study the responses of overhead power distribution lines to lightning at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida. The lightning was artificially initiated (triggered) from natural thunderclouds using the rocket-and-wire technique, and its current was directed to a phase conductor at midspan or at a pole near the center of the line. Experimental results and associated EMTP modeling are presented in this dissertation for the following line configurations: (1)a two-conductor, 740-m overhead distribution line with 2 arrester stations in 1996; (2)a four- conductor, 245-m overhead distribution line with 2 arrester stations in 1999; and (3)a four-conductor, 829-m overhead distribution line with 6 arrester stations in 2000. The three-phase lines tested in 1999 and 2000 were standard designs of a major Florida power company. Lightning peak currents injected into the lines ranged from 7 to 57 kA. Voltages and currents were measured at various locations along the line. Video and photographic cameras were used to image lightning channels and detect line flashovers. The significant results of the research are (1)flashovers between conductors were observed, both accompanied and not accompanied by arrester failures, (2)an arrester failed on seven of eight direct lightning strikes to the line in 2000, (3)arcing between conductors may prevent failures of arresters connected to the struck phase, (4)the bulk of the lightning current flows from the struck phase to neutral through the arresters closest to the strike point, (5)the withstand energy of the arresters can be exceeded due to the contribution from multiple strokes and/or relatively low-level, long-lasting current components, (6)the distribution of charge transferred to ground among multiple neutral grounds, which is determined by low-frequency, low-current grounding resistances is different from the

  9. Structure Learning in Power Distribution Networks

    SciTech Connect

    Deka, Deepjyoti; Chertkov, Michael; Backhaus, Scott N.

    2015-01-13

    Traditionally power distribution networks are either not observable or only partially observable. This complicates development and implementation of new smart grid technologies, such as these related to demand response, outage detection and management, and improved load-monitoring. Here, inspired by proliferation of the metering technology, we discuss statistical estimation problems in structurally loopy but operationally radial distribution grids consisting in learning operational layout of the network from measurements, e.g. voltage data, which are either already available or can be made available with a relatively minor investment. Our newly suggested algorithms apply to a wide range of realistic scenarios. The algorithms are also computationally efficient – polynomial in time – which is proven theoretically and illustrated computationally on a number of test cases. The technique developed can be applied to detect line failures in real time as well as to understand the scope of possible adversarial attacks on the grid.

  10. Klystron Cluster Scheme for ILC High Power RF Distribution

    SciTech Connect

    Nantista, Christopher; Adolphsen, Chris; /SLAC

    2009-07-06

    We present a concept for powering the main linacs of the International Linear Collider (ILC) by delivering high power RF from the surface via overmoded, low-loss waveguides at widely spaced intervals. The baseline design employs a two-tunnel layout, with klystrons and modulators evenly distributed along a service tunnel running parallel to the accelerator tunnel. This new idea eliminates the need for the service tunnel. It also brings most of the warm heat load to the surface, dramatically reducing the tunnel water cooling and HVAC requirements. In the envisioned configuration, groups of 70 klystrons and modulators are clustered in surface buildings every 2.5 km. Their outputs are combined into two half-meter diameter circular TE{sub 01} mode evacuated waveguides. These are directed via special bends through a deep shaft and along the tunnel, one upstream and one downstream. Each feeds approximately 1.25 km of linac with power tapped off in 10 MW portions at 38 m intervals. The power is extracted through a novel coaxial tap-off (CTO), after which the local distribution is as it would be from a klystron. The tap-off design is also employed in reverse for the initial combining.

  11. LH Power Losses In Front of the JET Launcher

    SciTech Connect

    Jacquet, P.; Arnoux, G.; Kirov, K.; Mailloux, J.; Mayoral, M.-L.; Ongena, J.

    2009-11-26

    In recent JET experiments, Lower Hybrid (LH) power losses in the Scrape-Off Layer (SOL) were characterized using infra-red (IR) thermography. Hot spots were observed on objects intercepting the field lines passing in front of the LH launcher, i.e. on poloidal limiters and on dumplates located at the top of the tokamak; their locations being in good agreement with magnetic field line tracing using the EFIT equilibrium code. The dumplate temperature was monitored while scanning the launcher position so that the radial distance between field lines intercepting the hot spots and the launcher was increased up to 3.5 cm. The dissipation layer in front of the launcher was estimated to be at least 3.5 cm wide, in agreement with recent measurements on Tore-Supra, but not with simple models that predict a dissipation layer in the mm range.

  12. LH Power Losses In Front of the JET Launcher

    NASA Astrophysics Data System (ADS)

    Jacquet, P.; Arnoux, G.; Colas, L.; Delpech, L.; Ekedahl, A.; Frigione, D.; Goniche, M.; Kirov, K.; Leguen, F.; Mailloux, J.; Mayoral, M.-L.; Ongena, J.; Petrzilka, V.; Portafaix, C.; Rimini, F.

    2009-11-01

    In recent JET experiments, Lower Hybrid (LH) power losses in the Scrape-Off Layer (SOL) were characterized using infra-red (IR) thermography. Hot spots were observed on objects intercepting the field lines passing in front of the LH launcher, i.e. on poloidal limiters and on dumplates located at the top of the tokamak; their locations being in good agreement with magnetic field line tracing using the EFIT equilibrium code. The dumplate temperature was monitored while scanning the launcher position so that the radial distance between field lines intercepting the hot spots and the launcher was increased up to 3.5 cm. The dissipation layer in front of the launcher was estimated to be at least 3.5 cm wide, in agreement with recent measurements on Tore-Supra, but not with simple models that predict a dissipation layer in the mm range.

  13. Intensity distribution analysis of cathodoluminescence using the energy loss distribution of electrons.

    PubMed

    Fukuta, Masahiro; Inami, Wataru; Ono, Atsushi; Kawata, Yoshimasa

    2016-01-01

    We present an intensity distribution analysis of cathodoluminescence (CL) excited with a focused electron beam in a luminescent thin film. The energy loss distribution is applied to the developed analysis method in order to determine the arrangement of the dipole locations along the path of the electron traveling in the film. Propagating light emitted from each dipole is analyzed with the finite-difference time-domain (FDTD) method. CL distribution near the film surface is evaluated as a nanometric light source. It is found that a light source with 30 nm widths is generated in the film by the focused electron beam. We also discuss the accuracy of the developed analysis method by comparison with experimental results. The analysis results are brought into good agreement with the experimental results by introducing the energy loss distribution.

  14. Robust distribution and use of electric power

    NASA Astrophysics Data System (ADS)

    Catalan Izquierdo, Saturnino

    2001-07-01

    One of the major problems related to the simultaneous operation of electrical converters in a wide open power system is the concordance between the characteristics of the feeder itself and the load. Nowadays we usually call Electric Power Quality or Electromagnetic Compatibility to this Concordance Degree. Currently, the most important non concordance are voltage sag (voltage dip) and short time interruptions, that is: decreasings in voltage RMS value lasting from some tenths of a second to several seconds. Current analysis usually study this problem from the feeder side, by means of morphological or stadistical approaches, or from the load side in order to evaluate immunity, emission or specific solutions. This line of research, undoubtly needed provided we need to know the current state of the power system and to increase the concordance degree, is not enough because of the huge variability between power lines and from one instant to another. Moreover, the legal boundaries that can support business decisions are not developed yet. The proposed new theory is widely contrasted by field and laboratory measurement. Detailed analysis include instant voltage, instant current, power system and load effects from many places inside the power system of Spain. This theory is a novel approach to the determination of Concordance Degree (CG) of a whole system (be it a distribution line or a single machine) and to the corrective steps needed to increase it. In addition, the proposed model allow a quantitative evaluation of corrective actions like the increase of energy system storage (in a mechanical to electrical convertible form) or/and the increase of the supplied reactive power. Profitability of corrective actions is mainly a function of the number of voltage dips (sags) and short time interruptions that happen in a given period of time. To reduce this number we have studied and developed new fault characterization and location algorithms designed specifically for medium

  15. Test report light duty utility arm power distribution system (PDS)

    SciTech Connect

    Clark, D.A.

    1996-03-04

    The Light Duty Utility Arm (LDUA) Power Distribution System has completed vendor and post-delivery acceptance testing. The Power Distribution System has been found to be acceptable and is now ready for integration with the overall LDUA system.

  16. A MILP-Based Distribution Optimal Power Flow Model for Microgrid Operation

    SciTech Connect

    Liu, Guodong; Starke, Michael R; Zhang, Xiaohu; Tomsovic, Kevin

    2016-01-01

    This paper proposes a distribution optimal power flow (D-OPF) model for the operation of microgrids. The proposed model minimizes not only the operating cost, including fuel cost, purchasing cost and demand charge, but also several performance indices, including voltage deviation, network power loss and power factor. It co-optimizes the real and reactive power form distributed generators (DGs) and batteries considering their capacity and power factor limits. The D-OPF is formulated as a mixed-integer linear programming (MILP). Numerical simulation results show the effectiveness of the proposed model.

  17. Energy summation method for energy loss computation in radial distribution networks

    SciTech Connect

    Taleski, R.; Rajicic, D.

    1996-05-01

    A method for energy loss calculation in radial distribution networks is presented. It is based on the statistical representation of the influence of different load curves in the network upon element power flows and on the oriented ordering of the network elements. Also, the paper proposes the use of different, but constant, voltages at each node, instead of nominal voltage at all nodes. The procedure is very simple, and it involves four steps: element ordering, calculation of second moments, power flow calculation with average loads at nodes, and energy calculation in network elements. The presented results illustrate that the algorithm has advantages over methods that use nominal voltage at each node for accuracy, and advantages over methods that calculate accurate energy losses for speed.

  18. Electric power processing, distribution, management and energy storage

    NASA Technical Reports Server (NTRS)

    Giudici, R. J.

    1980-01-01

    Power distribution subsystems are required for three elements of the SPS program: (1) orbiting satellite, (2) ground rectenna, and (3) Electric Orbiting Transfer Vehicle (EOTV). Power distribution subsystems receive electrical power from the energy conversion subsystem and provide the power busses rotary power transfer devices, switchgear, power processing, energy storage, and power management required to deliver control, high voltage plasma interactions, electric thruster interactions, and spacecraft charging of the SPS and the EOTV are also included as part of the power distribution subsystem design.

  19. Analysis of Power Converter Losses in Vector Control System of a Self-Excited Induction Generator

    NASA Astrophysics Data System (ADS)

    Bašić, Mateo; Vukadinović, Dinko; Polić, Miljenko

    2014-03-01

    This paper provides analysis of losses in the hysteresis-driven three-phase power converter with IGBTs and free-wheeling diodes. The converter under consideration is part of the self-excited induction generator (SEIG) vector control system. For the analysis, the SEIG vector control system is used in which the induction generator iron losses are taken into account. The power converter losses are determined by using a suitable loss estimation algorithm reported in literature. The chosen algorithm allows the power converter losses to be determined both by type (switching/conduction losses) and by converter component (IGBT/diode losses). The overall power converter losses are determined over wide ranges of rotor speed, dc-link voltage and load resistance, and subsequently used for offline correction of the overall control system's losses (efficiency) obtained through control system simulations with an ideal power converter. The control system's efficiency values obtained after the correction are compared with the measured values.

  20. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2007-01-01

    Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.

  1. Lower Hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    NASA Astrophysics Data System (ADS)

    Faust, I. C.

    2015-11-01

    For the first time, the power deposition of Lower Hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt (t <τE) response of the scrape-off-layer (SOL) plasma to LHRF power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be key for the LHRF edge power deposition physics. These observations support the existence a loss mechanism near the edge for LHRF at high density (ne > 1 . 0 .1020 [m-3]). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivates the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch. This work was performed on the Alcator C-Mod tokamak, a DoE Office of Science user facility, and is supported by USDoE award DE-FC02-99ER54512.

  2. Satellite control of electric power distribution

    NASA Technical Reports Server (NTRS)

    Bergen, L.

    1981-01-01

    An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

  3. Device for the distribution of motive power

    SciTech Connect

    Teroka, M.

    1986-12-30

    A device is described for the distribution of motive power comprising: a hollow shaft receiving input power from the drive device; a pinion shaft provided on the output side of the hollow shaft; a pinion gear rotatably supported on the pinion shaft; a pair of side gears meshed with the pinion gear; a front wheel drive shaft integrally coupled to one of the side gears and passing through the center of the hollow shaft; a differential case having an outer shell, a front and a rear end and being integrally formed with the outer side gear and enclosing the pinion shaft, pinion gear and side gears. A rear wheel drive shaft is coupled to the differential case through a drive gear formed on the outer shell of the differential case and an input gear is integrally connected to an end of the rear wheel drive shaft so as to mesh with the drive gear, the rear drive wheel drive shaft being located above the front wheel drive shaft.

  4. An improved AVC strategy applied in distributed wind power system

    NASA Astrophysics Data System (ADS)

    Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.

    2016-08-01

    Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.

  5. Influence of Mobile Users' Density Distribution on the CDMA Base Station Power

    NASA Astrophysics Data System (ADS)

    Lebl, Aleksandar; Mitić, Dragan; Popović, Miroslav; Markov, Žarko; Mileusnić, Mladen; Matić, Vladimir

    2016-12-01

    In this paper we analyze the influence of users' density distribution in one cell of CDMA mobile network (ie adjusted power control on the forward link) on base station emission power. This influence is analyzed for different circles radii around base station within which same emission power is generated for all mobile users, and for different values of propagation loss coefficient. It is proved that emission power in this cell must be increased comparing to the similar cell, which uses complete power control. The power increase is greater when greater number of users are situated near base station, and for greater values of propagation loss coefficient. The results are presented, illustrated by numerical examples and verified by simulation for three users' density distributions: uniform, decreasing and increasing density from the base station to the cell rim. The simulation process, which is based on random traffic process, is presented briefly.

  6. Patch Network for Power Allocation and Distribution in Smart Materials

    NASA Technical Reports Server (NTRS)

    Golembiewski, Walter T.

    2000-01-01

    The power allocation and distribution (PAD) circuitry is capable of allocating and distributing a single or multiple sources of power over multi-elements of a power user grid system. The purpose of this invention is to allocate and distribute power that is collected by individual patch rectennas to a region of specific power-user devices, such as actuators. The patch rectenna converts microwave power into DC power. Then this DC power is used to drive actuator devices. However, the power from patch rectennas is not sufficient to drive actuators unless all the collected power is effectively used to drive another group by allocation and distribution. The power allocation and distribution (PAD) circuitry solves the shortfall of power for devices in a large array. The PAD concept is based on the networked power control in which power collected over the whole array of rectennas is allocated to a sub domain where a group of devices is required to be activated for operation. Then the allocated power is distributed to individual element of power-devices in the sub domain according to a selected run-mode.

  7. Specific loss power in superparamagnetic hyperthermia: nanofluid versus composite

    NASA Astrophysics Data System (ADS)

    Osaci, M.; Cacciola, M.

    2017-01-01

    Currently, the magnetic hyperthermia induced by nanoparticles is of great interest in biomedical applications. In the literature, we can find a lot of models for magnetic hyperthermia, but many of them do not give importance to a significant detail, such as the geometry of nanoparticle positions in the system. Usually, a nanofluid is treated by considering random positions of the nanoparticles, geometry that is actually characteristic to the composite nanoparticles. To assess the error which is frequently made, in this paper we propose a comparative analysis between the specific loss power (SLP) in case of a nanofluid and the SLP in case of a composite with magnetic nanoparticles. We are going to use a superparamagnetic hyperthermia model based on the improved model for calculating the Néel relaxation time in a magnetic field oblique to the nanoparticle magnetic anisotropy axes, and on the improved theoretical model LRT (linear response theory) for SLP. To generate the nanoparticle geometry in the system, we are going to apply a Monte Carlo method to a nanofluid, by minimising the interaction potentials in liquid medium and, for a composite environment, a method for generating random positions of the nanoparticles in a given volume.

  8. Measurement of the temperature distribution inside the power cable using distributed temperature system

    NASA Astrophysics Data System (ADS)

    Jaros, Jakub; Liner, Andrej; Papes, Martin; Vasinek, Vladimir; Mach, Veleslav; Hruby, David; Kajnar, Tomas; Perecar, Frantisek

    2015-01-01

    Nowadays, the power cables are manufactured to fulfill the following condition - the highest allowable temperature of the cable during normal operation and the maximum allowable temperature at short circuit conditions cannot exceed the condition of the maximum allowable internal temperature. The distribution of the electric current through the conductor leads to the increase of the amplitude of electrons in the crystal lattice of the cables material. The consequence of this phenomenon is the increase of friction and the increase of collisions between particles inside the material, which causes the temperature increase of the carrying elements. The temperature increase is unwanted phenomena, because it is causing losses. In extreme cases, the long-term overload leads to the cable damaging or fire. This paper deals with the temperature distribution measurement inside the power cables using distributed temperature system. With cooperation with Kabex company, the tube containing optical fibers was installed into the center of power cables. These fibers, except telecommunications purposes, can be also used as sensors in measurements carrying out with distributed temperature system. These systems use the optical fiber as a sensor and allow the continual measurement of the temperature along the whole cable in real time with spatial resolution 1 m. DTS systems are successfully deployed in temperature measurement applications in industry areas yet. These areas include construction, drainage, hot water etc. Their advantages are low cost, resistance to electromagnetic radiation and the possibility of real time monitoring at the distance of 8 km. The location of the optical fiber in the center of the power cable allows the measurement of internal distribution of the temperature during overloading the cable. This measurement method can be also used for prediction of short-circuit and its exact location.

  9. Fast wave heating and edge power losses in NSTX and NSTX-U

    NASA Astrophysics Data System (ADS)

    Bertelli, Nicola

    2013-10-01

    Experimental studies of high harmonic fast wave (HHFW) heating on the National Spherical Torus Experiment (NSTX) have demonstrated that substantial HHFW power loss can occur along the open field lines in the scrape-off layer (SOL), but the mechanism behind the loss is not yet understood. Extended ray tracing and full wave codes are being applied to specific NSTX discharges in order to predict the causes of this power loss. Previous full wave simulations predict that cavity-like modes may form outside of the LCFS. We find that inserting a collisional loss in the SOL of AORSA to represent a damping process indicates an effective collisional term of ν / ω ~ [ 0 . 05 - 0 . 1 ] which is considerably larger than the ν / ω ~ 0 . 005 obtained with Spitzer resistivity, suggesting the damping scale of the loss mechanism. The magnitude of the edge collisional losses are being used to evaluate possible potential damping mechanisms in the SOL. Initial numerical analyses show that the presence of the SOL has a significant impact on the launched antenna spectrum. The upgrade of NSTX, NSTX-U, will operate with toroidal magnetic fields (BT) up to 1 T, nearly twice the values used on NSTX. The doubling of BT while retaining the 30 MHz RF frequency moves the heating regime for NSTX-U to the mid harmonic fast wave (MHFW) regime, which will be analyzed and contrasted with the HHFW regime on NSTX. These studies indicate that direct ion damping might be more significant in NSTX-U under TRANSP predicted full performance conditions. Modifications of fast ion distributions due to the interaction of fast waves with NBI will be presented in both MHFW and HHFW regimes. Work supported by the SciDAC Center for Wave-Plasma Interactions under DE-FC02-01ER54648 and the US DOE under DE-AC02-CH0911466.

  10. Efficiency and power loss in d. c. chopper circuits. [Theoretical calculation

    SciTech Connect

    Beck, M.O.

    1981-01-01

    The object of this paper was to investigate the efficiency and source of power losses of various classes of dc chopper circuits. The study involved a theoretical calculation of the power losses, supported by a considerable amount of practical work on full power-rated traction motor test bed. 3 refs.

  11. Locational Marginal Pricing in the Campus Power System at the Power Distribution Level

    SciTech Connect

    Hao, Jun; Gu, Yi; Zhang, Yingchen; Zhang, Jun Jason; Gao, David Wenzhong

    2016-11-14

    In the development of smart grid at distribution level, the realization of real-time nodal pricing is one of the key challenges. The research work in this paper implements and studies the methodology of locational marginal pricing at distribution level based on a real-world distribution power system. The pricing mechanism utilizes optimal power flow to calculate the corresponding distributional nodal prices. Both Direct Current Optimal Power Flow and Alternate Current Optimal Power Flow are utilized to calculate and analyze the nodal prices. The University of Denver campus power grid is used as the power distribution system test bed to demonstrate the pricing methodology.

  12. Developments in space power components for power management and distribution

    NASA Technical Reports Server (NTRS)

    Renz, D. D.

    1984-01-01

    Advanced power electronic components development for space applications is discussed. The components described include transformers, inductors, semiconductor devices such as transistors and diodes, remote power controllers, and transmission lines.

  13. Refinements and practical implementation of a power based loss of grid detection algorithm for embedded generators

    NASA Astrophysics Data System (ADS)

    Barrett, James

    The incorporation of small, privately owned generation operating in parallel with, and supplying power to, the distribution network is becoming more widespread. This method of operation does however have problems associated with it. In particular, a loss of the connection to the main utility supply which leaves a portion of the utility load connected to the embedded generator will result in a power island. This situation presents possible dangers to utility personnel and the public, complications for smooth system operation and probable plant damage should the two systems be reconnected out-of-synchronism. Loss of Grid (or Islanding), as this situation is known, is the subject of this thesis. The work begins by detailing the requirements for operation of generation embedded in the utility supply with particular attention drawn to the requirements for a loss of grid protection scheme. The mathematical basis for a new loss of grid protection algorithm is developed and the inclusion of the algorithm in an integrated generator protection scheme described. A detailed description is given on the implementation of the new algorithm in a microprocessor based relay hardware to allow practical tests on small embedded generation facilities, including an in-house multiple generator test facility. The results obtained from the practical tests are compared with those obtained from simulation studies carried out in previous work and the differences are discussed. The performance of the algorithm is enhanced from the theoretical algorithm developed using the simulation results with simple filtering together with pattern recognition techniques. This provides stability during severe load fluctuations under parallel operation and system fault conditions and improved performance under normal operating conditions and for loss of grid detection. In addition to operating for a loss of grid connection, the algorithm will respond to load fluctuations which occur within a power island

  14. The invariances of power law size distributions.

    PubMed

    Frank, Steven A

    2016-01-01

    Size varies. Small things are typically more frequent than large things. The logarithm of frequency often declines linearly with the logarithm of size. That power law relation forms one of the common patterns of nature. Why does the complexity of nature reduce to such a simple pattern? Why do things as different as tree size and enzyme rate follow similarly simple patterns? Here I analyze such patterns by their invariant properties. For example, a common pattern should not change when adding a constant value to all observations. That shift is essentially the renumbering of the points on a ruler without changing the metric information provided by the ruler. A ruler is shift invariant only when its scale is properly calibrated to the pattern being measured. Stretch invariance corresponds to the conservation of the total amount of something, such as the total biomass and consequently the average size. Rotational invariance corresponds to pattern that does not depend on the order in which underlying processes occur, for example, a scale that additively combines the component processes leading to observed values. I use tree size as an example to illustrate how the key invariances shape pattern. A simple interpretation of common pattern follows. That simple interpretation connects the normal distribution to a wide variety of other common patterns through the transformations of scale set by the fundamental invariances.

  15. The invariances of power law size distributions

    PubMed Central

    Frank, Steven A.

    2016-01-01

    Size varies. Small things are typically more frequent than large things. The logarithm of frequency often declines linearly with the logarithm of size. That power law relation forms one of the common patterns of nature. Why does the complexity of nature reduce to such a simple pattern? Why do things as different as tree size and enzyme rate follow similarly simple patterns? Here I analyze such patterns by their invariant properties. For example, a common pattern should not change when adding a constant value to all observations. That shift is essentially the renumbering of the points on a ruler without changing the metric information provided by the ruler. A ruler is shift invariant only when its scale is properly calibrated to the pattern being measured. Stretch invariance corresponds to the conservation of the total amount of something, such as the total biomass and consequently the average size. Rotational invariance corresponds to pattern that does not depend on the order in which underlying processes occur, for example, a scale that additively combines the component processes leading to observed values. I use tree size as an example to illustrate how the key invariances shape pattern. A simple interpretation of common pattern follows. That simple interpretation connects the normal distribution to a wide variety of other common patterns through the transformations of scale set by the fundamental invariances. PMID:27928497

  16. Design note about a 75 KVA quiet power distribution system

    SciTech Connect

    Visser, A.T.

    1984-04-05

    This note describes a 75KVA quiet power distribution system for X 653 in neutrino Lab D. It is fed from the regular AC distribution which exists in the building and it has no standby power. Its purpose is to remove electrical disturbances which are present on the regular AC distribution.

  17. Efficient two-level cryogenic power distribution system

    NASA Astrophysics Data System (ADS)

    Mueller, O. M.; Mueller, E. K.

    2002-05-01

    The availability of new technologies such as high-temperature superconducting (HTS) cables, high-voltage, high-speed semiconductor switches, and cryogenic power conversion suggests that one considers how these technologies can be combined and applied effectively to provide a more efficient energy distribution system. The present-day 60 Hz concept is, after all, a century old. Advantages can be obtained by combining DC and high-frequency AC technologies. DC transmission solves the problem of AC losses in HTS cables and high-frequency switching techniques reduce size, weight and cost. This paper proposes and discusses a distribution system based on two DC voltage levels (˜4 kVDC/650 VDC) interconnected with DC/DC converters using high-voltage insulated-gate bipolar transistors (HV-IGBT's), integrated gate-commutated thyristors (IGCT's), or MOS-controlled turn-off thyristors (MTO's) operated at cryogenic temperatures. Cryo-MOSFET DC/AC inverters provide the 60 Hz, 240/120 VAC user voltages. HTS cables supply power as well as the cooling fluid liquid nitrogen (LN2). The load shedding properties of such a system based on the use of LN2 are evaluated. The proposed concept is suitable for city blocks with many high-rise buildings. It provides an increase in efficiency and therefore contributes to the reduction of global warming.

  18. Power-Law Distributions Based on Exponential Distributions: Latent Scaling, Spurious Zipf's Law, and Fractal Rabbits

    NASA Astrophysics Data System (ADS)

    Chen, Yanguang

    2015-03-01

    The difference between the inverse power function and the negative exponential function is significant. The former suggests a complex distribution, while the latter indicates a simple distribution. However, the association of the power-law distribution with the exponential distribution has been seldom researched. This paper is devoted to exploring the relationships between exponential laws and power laws from the angle of view of urban geography. Using mathematical derivation and numerical experiments, I reveal that a power-law distribution can be created through a semi-moving average process of an exponential distribution. For the distributions defined in a one-dimension space (e.g. Zipf's law), the power exponent is 1; while for those defined in a two-dimension space (e.g. Clark's law), the power exponent is 2. The findings of this study are as follows. First, the exponential distributions suggest a hidden scaling, but the scaling exponents suggest a Euclidean dimension. Second, special power-law distributions can be derived from exponential distributions, but they differ from the typical power-law distributions. Third, it is the real power-law distributions that can be related with fractal dimension. This study discloses an inherent link between simplicity and complexity. In practice, maybe the result presented in this paper can be employed to distinguish the real power laws from spurious power laws (e.g. the fake Zipf distribution).

  19. Fuel Cycle Comparison for Distributed Power Technologies

    SciTech Connect

    Elgowainy, A.; Wang, M. Q.

    2008-11-15

    This report examines backup power and prime power systems and addresses the potential energy and environmental effects of substituting fuel cells for existing combustion technologies based on microturbines and internal combustion engines.

  20. Power loss in open cavity diodes and a modified Child-Langmuir law

    SciTech Connect

    Biswas, Debabrata; Kumar, Raghwendra; Puri, R.R.

    2005-09-15

    Diodes used in most high power devices are inherently open. It is shown that under such circumstances, there is a loss of electromagnetic radiation leading to a lower critical current as compared to closed diodes. The power loss can be incorporated in the standard Child-Langmuir framework by introducing an effective potential. The modified Child-Langmuir law can be used to predict the maximum power loss for a given plate separation and potential difference as well as the maximum transmitted current for this power loss. The effectiveness of the theory is tested numerically.

  1. Distributed energy store powered railguns for hypervelocity launch

    NASA Astrophysics Data System (ADS)

    Maas, Brian L.; Bauer, David P.; Marshall, Richard A.

    1993-01-01

    Highly distributed power supplies are proposed as a basis for current difficulties with hypervelocity railgun power-supply compactness. This distributed power supply configuration reduces rail-to-rail voltage behind the main armature, thereby reducing the tendency for secondary armature current formation; secondary current elimination is essential for achieving the efficiencies associated with muzzle velocity above 6 km/sec. Attention is given to analytical and experimental results for two distributed energy storage schemes.

  2. Prediction of reserves using multivariate power-normal mixture distribution

    NASA Astrophysics Data System (ADS)

    Ling, Ang Siew; Hin, Pooi Ah

    2016-10-01

    Recently, in the area on stochastic loss reserving, there are a number of papers which analyze the individual claims data using the Position Dependent Marked Poisson Process. The present paper instead uses a different type of individual data. For the i-th (1≤i≤n) customer, these individual data include the sum insured si together with the amount paid yi j and the amount ai j reported but not yet paid in the j-th (1 ≤ j ≤ 6) development year. A technique based on multivariate power-normal mixture distribution is already available for predicting the future value (yi j + 1, ai j + 1) using the present year value (yi j, ai j) and the sum insured si. Presently the above technique is improved by the transformation of distribution which is defined on the whole real line to one which is non-negative and having approximately the same first four moments as the original distribution. It is found that, for the dataset considered in this paper, the improved method gives a better estimate for the reserve when compared with the chain ladder reserve estimate. Furthermore, the method is expected to provide a fairly reliable value for the Provision of Risk Margin for Adverse Deviation (PRAD).

  3. System optimization of a long-range Brillouin-loss-based distributed fiber sensor.

    PubMed

    Dong, Yongkang; Chen, Liang; Bao, Xiaoyi

    2010-09-20

    We report a high-performance 25 km Brillouin-loss-based distributed fiber sensor through optimizing system parameters. First, the Brillouin spectrum distortion and measurement error induced by the excess amplification on probe pulse are investigated, and the results indicate that a low continuous-wave pump power is essential to decrease the measurement error. Then an optimal pulse pair is determined through the differential Brillouin gain evolution along the entire sensing fiber in a differential pulse-width pair Brillouin optical time domain analysis. Using dispersion-shifted fiber to allow a high-power probe pulse, we realize a 25 km sensing range with a spatial resolution of 30 cm and a strain accuracy of ±20 με, which we believe is the best performance in such a length, to the best of our knowledge.

  4. 26 CFR 1.731-1 - Extent of recognition of gain or loss on distribution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... recognition of gain or loss on distribution. (a) Recognition of gain or loss to partner—(1) Recognition of gain. (i) Where money is distributed by a partnership to a partner, no gain shall be recognized to the partner except to the extent that the amount of money distributed exceeds the adjusted basis of...

  5. 26 CFR 1.731-1 - Extent of recognition of gain or loss on distribution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... of recognition of gain or loss on distribution. (a) Recognition of gain or loss to partner—(1) Recognition of gain. (i) Where money is distributed by a partnership to a partner, no gain shall be recognized to the partner except to the extent that the amount of money distributed exceeds the adjusted...

  6. Price Based Local Power Distribution Management System (Local Power Distribution Manager) v1.0

    SciTech Connect

    BROWN, RICHARD E.; CZARNECKI, STEPHEN; SPEARS, MICHAEL; NORDMAN, BRUCE; BROUGHTON, ALEX; VON HIPPEL, MICHAEL; LIAO, ANNA

    2016-11-28

    A trans-active energy micro-grid controller is implemented in the VOLTTRON distributed control platform. The system uses the price of electricity as the mechanism for conducting transactions that are used to manage energy use and to balance supply and demand. In order to allow testing and analysis of the control system, the implementation is designed to run completely as a software simulation, while allowing the inclusion of selected hardware that physically manages power. Equipment to be integrated with the micro-grid controller must have an IP (Internet Protocol)-based network connection and a software "driver" must exist to translate data communications between the device and the controller.

  7. Novel binary PSO algorithm based optimization of transmission expansion planning considering power losses

    NASA Astrophysics Data System (ADS)

    Astuty; Haryono, T.

    2016-04-01

    Transmission expansion planning (TEP) is one of the issue that have to be faced caused by addition of large scale power generation into the existing power system. Optimization need to be conducted to get optimal solution technically and economically. Several mathematic methods have been applied to provide optimal allocation of new transmission line such us genetic algorithm, particle swarm optimization and tabu search. This paper proposed novel binary particle swarm optimization (NBPSO) to determine which transmission line should be added to the existing power system. There are two scenerios in this simulation. First, considering transmission power losses and the second is regardless transmission power losses. NBPSO method successfully obtain optimal solution in short computation time. Compare to the first scenario, the number of new line in second scenario which regardless power losses is less but produces high power losses that cause the cost becoming extremely expensive.

  8. Power-law ansatz in complex systems: Excessive loss of information

    NASA Astrophysics Data System (ADS)

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  9. Power-law ansatz in complex systems: Excessive loss of information.

    PubMed

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  10. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width, and ratio on total mesh power loss for a wide range of speeds, torques, and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling, and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine pitched gears had higher peak efficiencies but low part load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full load loss except at low speeds.

  11. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  12. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  13. 14 CFR 23.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Power source capacity and distribution. 23.1310 Section 23.1310 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment General § 23.1310 Power source capacity and distribution. (a) Each installation whose...

  14. Inverter power module with distributed support for direct substrate cooling

    DOEpatents

    Miller, David Harold [San Pedro, CA; Korich, Mark D [Chino Hills, CA; Ward, Terence G [Redondo Beach, CA; Mann, Brooks S [Redondo Beach, CA

    2012-08-21

    Systems and/or methods are provided for an inverter power module with distributed support for direct substrate cooling. An inverter module comprises a power electronic substrate. A first support frame is adapted to house the power electronic substrate and has a first region adapted to allow direct cooling of the power electronic substrate. A gasket is interposed between the power electronic substrate and the first support frame. The gasket is configured to provide a seal between the first region and the power electronic substrate. A second support frame is adapted to house the power electronic substrate and joined to the first support frame to form the seal.

  15. A Testbed for Deploying Distributed State Estimation in Power Grid

    SciTech Connect

    Jin, Shuangshuang; Chen, Yousu; Rice, Mark J.; Liu, Yan; Gorton, Ian

    2012-07-22

    Abstract—With the increasing demand, scale and data information of power systems, fast distributed applications are becoming more important in power system operation and control. This paper proposes a testbed for evaluating power system distributed applications, considering data exchange among distributed areas. A high-performance computing (HPC) version of distributed state estimation is implemented and used as a distributed application example. The IEEE 118-bus system is used to deploy the parallel distributed state estimation, and the MeDICi middleware is used for data communication. The performance of the testbed demonstrates its capability to evaluate parallel distributed state estimation by leveraging the HPC paradigm. This testbed can also be applied to evaluate other distributed applications.

  16. Loss of Load Probability Calculation for West Java Power System with Nuclear Power Plant Scenario

    NASA Astrophysics Data System (ADS)

    Azizah, I. D.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.; Shafii, M. A.

    2017-03-01

    Loss of Load Probability (LOLP) index showing the quality and performance of an electrical system. LOLP value is affected by load growth, the load duration curve, forced outage rate of the plant, number and capacity of generating units. This reliability index calculation begins with load forecasting to 2018 using multiple regression method. Scenario 1 with compositions of conventional plants produce the largest LOLP in 2017 amounted to 71.609 days / year. While the best reliability index generated in scenario 2 with the NPP amounted to 6.941 days / year in 2015. Improved reliability of systems using nuclear power more efficiently when compared to conventional plants because it also has advantages such as emission-free, inexpensive fuel costs, as well as high level of plant availability.

  17. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2006-01-01

    Secondary seal leakage in jet engine applications results in power losses to the engine cycle. Likewise, seal power loss in jet engines not only result in efficiency loss but also increase the heat input into the engine resulting in reduced component lives. Experimental work on labyrinth and annular seals was performed at NASA Glenn Research Center to quantify seal leakage and power loss at various temperatures, seal pressure differentials, and surface speeds. Data from annular and labyrinth seals are compared with previous brush and finger seal test results. Data are also compared to literature. Annular and labyrinth seal leakage rates are 2 to 3 times greater than brush and finger seal rates. Seal leakage decreases with increasing speed but increases with increasing test temperature due to thermal expansion mismatch. Also seal power loss increases with surface speed, seal pressure differential, mass flow rate, and radial clearance. Annular and labyrinth seal power losses were higher than those of brush or finger seal data. The brush seal power loss was 15 to 30 percent lower than annular and labyrinth seal power loss.

  18. Combined effect of CVR and penetration of DG in the voltage profile and losses of lowvoltage secondary distribution networks

    NASA Astrophysics Data System (ADS)

    Bokhari, Abdullah

    Demarcations between traditional distribution power systems and distributed generation (DG) architectures are increasingly evolving as higher DG penetration is introduced in the system. The concerns in existing electric power systems (EPSs) to accommodate less restrictive interconnection policies while maintaining reliability and performance of power delivery have been the major challenge for DG growth. In this dissertation, the work is aimed to study power quality, energy saving and losses in a low voltage distributed network under various DG penetration cases. Simulation platform suite that includes electric power system, distributed generation and ZIP load models is implemented to determine the impact of DGs on power system steady state performance and the voltage profile of the customers/loads in the network under the voltage reduction events. The investigation designed to test the DG impact on power system starting with one type of DG, then moves on multiple DG types distributed in a random case and realistic/balanced case. The functionality of the proposed DG interconnection is designed to meet the basic requirements imposed by the various interconnection standards, most notably IEEE 1547, public service commission, and local utility regulation. It is found that implementation of DGs on the low voltage secondary network would improve customer's voltage profile, system losses and significantly provide energy savings and economics for utilities. In a network populated with DGs, utility would have a uniform voltage profile at the customers end as the voltage profile becomes more concentrated around targeted voltage level. The study further reinforced the concept that the behavior of DG in distributed network would improve voltage regulation as certain percentage reduction on utility side would ensure uniform percentage reduction seen by all customers and reduce number of voltage violations.

  19. Brief communication: coaxial lines for multiphase power distribution.

    PubMed

    Barnes, F S; Harwick, P; Banerjee, A

    1996-01-01

    A coaxial cable can be used to reduce the magnetic and electric fields that extend into environments in the vicinity of transmission lines and distribution lines and in-house or building wiring for power distribution systems. The use of the coaxial geometry may prove useful in cases where there are environmental concerns with respect to health effects and in cases where there is a need to run high-speed data communications in close proximity to power distribution systems.

  20. Pressure Loss Modulus for correlation of steady-state {Delta}P across uniformly distributed-loss devices

    SciTech Connect

    Nunz, G.J.

    1993-10-01

    A dimensionless group, called a Pressure Loss Modulus (N{sub PL}), is introduced which, in conjunction with an appropriately defined Reynolds number, is of considerable engineering utility in correlating steady-state {Delta}P vs. flow calibration data and subsequently as a predictor, using the same or a different fluid, in uniformly distributed pressure loss devices. It is particularly useful under operation in the transition regime. Applications of this simple bivariate correlation to three diverse devices of particular interest for small liquid rocket engine fluid systems are discussed: large L/D capillary tube restrictors; packed granular catalyst beds; and stacked vortex-loss disc restrictors.

  1. Minimizing Losses in a Space Laser Power Beaming System

    DTIC Science & Technology

    2010-03-01

    focused sunlight onto enemy ships to set them ablaze (Perram, 2009). In more recent history the inventor Nikola Tesla proposed a wireless power...in which to power modern conveniences than running wires through walls or along ceilings and floors. This Tesla Effect can be easily demonstrated...using a Tesla Coil to ionize air particles and create a current in a modern fluorescent tube. Once the device has been turned on simply holding the

  2. Thresholded Power law Size Distributions of Instabilities in Astrophysics

    NASA Astrophysics Data System (ADS)

    Aschwanden, Markus J.

    2015-11-01

    Power-law-like size distributions are ubiquitous in astrophysical instabilities. There are at least four natural effects that cause deviations from ideal power law size distributions, which we model here in a generalized way: (1) a physical threshold of an instability; (2) incomplete sampling of the smallest events below a threshold x0; (3) contamination by an event-unrelated background xb; and (4) truncation effects at the largest events due to a finite system size. These effects can be modeled in the simplest terms with a “thresholded power law” distribution function (also called generalized Pareto [type II] or Lomax distribution), N(x){dx}\\propto {(x+{x}0)}-a{dx}, where x0 > 0 is positive for a threshold effect, while x0 < 0 is negative for background contamination. We analytically derive the functional shape of this thresholded power law distribution function from an exponential growth evolution model, which produces avalanches only when a disturbance exceeds a critical threshold x0. We apply the thresholded power law distribution function to terrestrial, solar (HXRBS, BATSE, RHESSI), and stellar flare (Kepler) data sets. We find that the thresholded power law model provides an adequate fit to most of the observed data. Major advantages of this model are the automated choice of the power law fitting range, diagnostics of background contamination, physical instability thresholds, instrumental detection thresholds, and finite system size limits. When testing self-organized criticality models that predict ideal power laws, we suggest including these natural truncation effects.

  3. Electric power processing, distribution and control for advanced aerospace vehicles.

    NASA Technical Reports Server (NTRS)

    Krausz, A.; Felch, J. L.

    1972-01-01

    The results of a current study program to develop a rational basis for selection of power processing, distribution, and control configurations for future aerospace vehicles including the Space Station, Space Shuttle, and high-performance aircraft are presented. Within the constraints imposed by the characteristics of power generation subsystems and the load utilization equipment requirements, the power processing, distribution and control subsystem can be optimized by selection of the proper distribution voltage, frequency, and overload/fault protection method. It is shown that, for large space vehicles which rely on static energy conversion to provide electric power, high-voltage dc distribution (above 100 V dc) is preferable to conventional 28 V dc and 115 V ac distribution per MIL-STD-704A. High-voltage dc also has advantages over conventional constant frequency ac systems in many aircraft applications due to the elimination of speed control, wave shaping, and synchronization equipment.

  4. Analysis of Apex Seal Friction Power Loss in Rotary Engines

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Owen, A. Karl

    2010-01-01

    An analysis of the frictional losses from the apex seals in a rotary engine was developed. The modeling was initiated with a kinematic analysis of the rotary engine. Next a modern internal combustion engine analysis code was altered for use in a rotary engine to allow the calculation of the internal combustion pressure as a function of rotor rotation. Finally the forces from the spring, inertial, and combustion pressure on the seal were combined to provide the frictional horsepower assessment.

  5. Statistical analyses support power law distributions found in neuronal avalanches.

    PubMed

    Klaus, Andreas; Yu, Shan; Plenz, Dietmar

    2011-01-01

    The size distribution of neuronal avalanches in cortical networks has been reported to follow a power law distribution with exponent close to -1.5, which is a reflection of long-range spatial correlations in spontaneous neuronal activity. However, identifying power law scaling in empirical data can be difficult and sometimes controversial. In the present study, we tested the power law hypothesis for neuronal avalanches by using more stringent statistical analyses. In particular, we performed the following steps: (i) analysis of finite-size scaling to identify scale-free dynamics in neuronal avalanches, (ii) model parameter estimation to determine the specific exponent of the power law, and (iii) comparison of the power law to alternative model distributions. Consistent with critical state dynamics, avalanche size distributions exhibited robust scaling behavior in which the maximum avalanche size was limited only by the spatial extent of sampling ("finite size" effect). This scale-free dynamics suggests the power law as a model for the distribution of avalanche sizes. Using both the Kolmogorov-Smirnov statistic and a maximum likelihood approach, we found the slope to be close to -1.5, which is in line with previous reports. Finally, the power law model for neuronal avalanches was compared to the exponential and to various heavy-tail distributions based on the Kolmogorov-Smirnov distance and by using a log-likelihood ratio test. Both the power law distribution without and with exponential cut-off provided significantly better fits to the cluster size distributions in neuronal avalanches than the exponential, the lognormal and the gamma distribution. In summary, our findings strongly support the power law scaling in neuronal avalanches, providing further evidence for critical state dynamics in superficial layers of cortex.

  6. A study of power conditioning and power distribution and components

    NASA Technical Reports Server (NTRS)

    Horton, H. M.; Honnell, M. A.

    1973-01-01

    A comprehensive simulation and analysis performed on the operation of the regulator part of the Charger/Battery/Regulator Module (CBRM) are detailed. The CBRM is utilized as an integral component of the Skylab/Apollo Telescope Mount (ATM) electrical power system and contains a switching mode electronic regulator. Implementing circuit analysis techniques, pertinent voltages and currents are calculated; these, in turn, are incorporated into the regulator system study. Investigation of the turn-on and turn-off times associated with the switching circuitry is performed and an examination is made on these calculations. A simulation model computer program is utilized to generate graphs that relate various CBRM parameters to one another.

  7. Historic distribution and recent loss of tigers in China.

    PubMed

    Kang, Aili; Xie, Yan; Tang, Jirong; Sanderson, Eric W; Ginsberg, Joshua R; Zhang, Endi

    2010-12-01

    Historical records can provide important evidence of changes in distributions of wildlife species. Here we discuss the distribution of the tiger (Panthera tigris Linnaeus, 1758) over the past 2000 years in China based on 2635 historical records. We also compare tiger distributions outlined in these records with ecosystem type maps. Throughout this time period, tigers maintained a broad distribution across 7 biomes (from forests to deserts). However, in recent decades the range has been significantly condensed. Today, only 2 populations remain, neither of which is independently viable. Tigers have completely disappeared from the temperate broadleaf and mixed forests of central China, a region that was traditionally their most important biome in China. The continued presence of wild tigers in China is highly dependent on significant conservation measures.

  8. Description of a 20 Kilohertz power distribution system

    NASA Technical Reports Server (NTRS)

    Hansen, I. G.

    1986-01-01

    A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

  9. Calculated CIM Power Distributions for Coil Design

    SciTech Connect

    Hardy, B.J.

    1999-02-17

    Excessive bed expansion and material expulsion have occurred during experiments with the 3-inch diameter Cylindrical Induction Melter (CIM). Both events were attributed in part to the high power density in the bottom of the melter and the correspondingly high temperatures there. It is believed that the high temperatures resulted in the generation of gasses at the bottom of the bed which could not escape. The gasses released during heating and the response of the bed to gas evolution depend upon the composition of the bed.

  10. Optimization of magnetic neurostimulation waveforms for minimum power loss.

    PubMed

    Goetz, S M; Truong, N C; Gerhofer, M G; Peterchev, A V; Herzog, H-G; Weyh, T

    2012-01-01

    Magnetic stimulation is a key tool in experimental brain research and several clinical applications. Whereas coil designs and the spatial field properties have been intensively studied in the literature, the temporal dynamics of the field has received little attention. The available pulse shapes are typically determined by the relatively limited capabilities of commercial stimulation devices instead of efficiency or optimality. Furthermore, magnetic stimulation is relatively inefficient with respect to the required energy compared to other neurostimulation techniques. We therefore analyze and optimize the waveform dynamics with a nonlinear model of a mammalian motor axon for the first time, without any pre-definition of waveform candidates. We implemented an unbiased and stable numerical algorithm using variational calculus in combination with a global optimization method. This approach yields very stable results with comprehensible characteristic properties, such as a first phase which reduces ohmic losses in the subsequent pulse phase. We compare the energy loss of these optimal waveforms with the waveforms generated by existing magnetic stimulation devices.

  11. Space Station Freedom power management and distribution system design

    NASA Technical Reports Server (NTRS)

    Teren, Fred

    1989-01-01

    The design is described of the Space Station Freedom Power Management and Distribution (PMAD) System. In addition, the significant trade studies which were conducted are described, which led to the current PMAD system configuration.

  12. Power distribution in two-dimensional optical network channels

    NASA Astrophysics Data System (ADS)

    Wang, Dong-Xue; Karim, Mohammad A.

    1996-04-01

    The power distribution in two-dimensional optical network channels is analyzed. The maximum number of allowable channels as determined by the characteristics of optical detector is identified, in particular, for neural-network and wavelet-transform applications.

  13. Experimental quantum key distribution with simulated ground-to-satellite photon losses and processing limitations

    NASA Astrophysics Data System (ADS)

    Bourgoin, Jean-Philippe; Gigov, Nikolay; Higgins, Brendon L.; Yan, Zhizhong; Meyer-Scott, Evan; Khandani, Amir K.; Lütkenhaus, Norbert; Jennewein, Thomas

    2015-11-01

    Quantum key distribution (QKD) has the potential to improve communications security by offering cryptographic keys whose security relies on the fundamental properties of quantum physics. The use of a trusted quantum receiver on an orbiting satellite is the most practical near-term solution to the challenge of achieving long-distance (global-scale) QKD, currently limited to a few hundred kilometers on the ground. This scenario presents unique challenges, such as high photon losses and restricted classical data transmission and processing power due to the limitations of a typical satellite platform. Here we demonstrate the feasibility of such a system by implementing a QKD protocol, with optical transmission and full post-processing, in the high-loss regime using minimized computing hardware at the receiver. Employing weak coherent pulses with decoy states, we demonstrate the production of secure key bits at up to 56.5 dB of photon loss. We further illustrate the feasibility of a satellite uplink by generating a secure key while experimentally emulating the varying losses predicted for realistic low-Earth-orbit satellite passes at 600 km altitude. With a 76 MHz source and including finite-size analysis, we extract 3374 bits of a secure key from the best pass. We also illustrate the potential benefit of combining multiple passes together: while one suboptimal "upper-quartile" pass produces no finite-sized key with our source, the combination of three such passes allows us to extract 165 bits of a secure key. Alternatively, we find that by increasing the signal rate to 300 MHz it would be possible to extract 21 570 bits of a secure finite-sized key in just a single upper-quartile pass.

  14. A comparative study of electric power distribution systems for spacecraft

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.

    1990-01-01

    The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.

  15. Power laws in citation distributions: evidence from Scopus.

    PubMed

    Brzezinski, Michal

    Modeling distributions of citations to scientific papers is crucial for understanding how science develops. However, there is a considerable empirical controversy on which statistical model fits the citation distributions best. This paper is concerned with rigorous empirical detection of power-law behaviour in the distribution of citations received by the most highly cited scientific papers. We have used a large, novel data set on citations to scientific papers published between 1998 and 2002 drawn from Scopus. The power-law model is compared with a number of alternative models using a likelihood ratio test. We have found that the power-law hypothesis is rejected for around half of the Scopus fields of science. For these fields of science, the Yule, power-law with exponential cut-off and log-normal distributions seem to fit the data better than the pure power-law model. On the other hand, when the power-law hypothesis is not rejected, it is usually empirically indistinguishable from most of the alternative models. The pure power-law model seems to be the best model only for the most highly cited papers in "Physics and Astronomy". Overall, our results seem to support theories implying that the most highly cited scientific papers follow the Yule, power-law with exponential cut-off or log-normal distribution. Our findings suggest also that power laws in citation distributions, when present, account only for a very small fraction of the published papers (less than 1 % for most of science fields) and that the power-law scaling parameter (exponent) is substantially higher (from around 3.2 to around 4.7) than found in the older literature.

  16. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P.; Donnelly, Matthew K.; Dagle, Jeffery E.

    2006-12-12

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  17. Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

    DOEpatents

    Chassin, David P [Pasco, WA; Donnelly, Matthew K [Kennewick, WA; Dagle, Jeffery E [Richland, WA

    2011-12-06

    Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

  18. Accumulation, loss and molecular distribution of cadmium in Mytilus edulis

    NASA Astrophysics Data System (ADS)

    Scholz, N.

    1980-03-01

    In Mytilus edulis, accumulation and loss of Cd were analyzed under experimental conditions. Cd uptake by the whole soft body is linear, increasing significantly with increasing Cd concentrations in the uptake medium. Until 100 µg Cd l-1, neither limitation of uptake nor any saturation process can be observed. Loss of Cd, measured after transfer of experimentally contaminated mussels to natural sea water, is exponential; biological half lives vary between 14 and 29 days. Gills are the primary sites of Cd uptake from the water, whereas in mid-gut gland, kidney, and mantle the uptake is retarded during the first few days. The mid-gut gland not only bears the main body load of Cd, but also shows the highest Cd concentrations. Gel chromatographic studies of mid-gut gland proteins reveal that Cd is eluated over the whole molecular weight range. Three metallothionein-like proteins with molecular weights of 6,600, 13,200, and 21,000 Dalton could be established. However, they cannot be taken as effective detoxification proteins, because more than 50% of the accumulated metal is bound to high molecular weight proteins.

  19. 62. View of amplifiermodulator control system with power distribution panel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. View of amplifier-modulator control system with power distribution panel on left, control power supply in middle, and amplifier modulator on right, second floor in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  20. Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

    NASA Technical Reports Server (NTRS)

    Soltis, James V.

    1998-01-01

    The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

  1. Power losses in PWM-VSI inverter using NPT or PT IGBT devices

    SciTech Connect

    Blaabjerg, F.; Munk-Nielsen, S.; Pedersen, J.K.; Jaeger, U.

    1995-05-01

    This paper investigates the power losses for two different IGBT technologies (Non Punch Through and Punch Through) for use in PWM-VSI inverters in order to choose the right device technology for a given application. A loss model of the inverter is developed based on experimental determination of the power losses. The loss model is used on two different modulation strategies which are a sine wave with a third harmonic added and a 60{degree}-PWM modulation where only two inverterlegs are active at the same time. The two IGBT technologies are characterized on an advanced measurement system which is described. The total power losses in the inverter are estimated simulation at different conditions and it is concluded that the Non Punch Through technology is most useful for higher switching frequencies, while the Punch Through technology is special useful at lower switching frequencies and high load currents. It is also concluded the 60{degree}-PWM modulation has the lowest power losses and the power losses are almost independent of phase angle cos({phi}) for normal motor operation.

  2. A generalization of the power law distribution with nonlinear exponent

    NASA Astrophysics Data System (ADS)

    Prieto, Faustino; Sarabia, José María

    2017-01-01

    The power law distribution is usually used to fit data in the upper tail of the distribution. However, commonly it is not valid to model data in all the range. In this paper, we present a new family of distributions, the so-called Generalized Power Law (GPL), which can be useful for modeling data in all the range and possess power law tails. To do that, we model the exponent of the power law using a non-linear function which depends on data and two parameters. Then, we provide some basic properties and some specific models of that new family of distributions. After that, we study a relevant model of the family, with special emphasis on the quantile and hazard functions, and the corresponding estimation and testing methods. Finally, as an empirical evidence, we study how the debt is distributed across municipalities in Spain. We check that power law model is only valid in the upper tail; we show analytically and graphically the competence of the new model with municipal debt data in the whole range; and we compare the new distribution with other well-known distributions including the Lognormal, the Generalized Pareto, the Fisk, the Burr type XII and the Dagum models.

  3. Electric Power quality Analysis in research reactor: Impacts on nuclear safety assessment and electrical distribution reliability

    SciTech Connect

    Touati, Said; Chennai, Salim; Souli, Aissa

    2015-07-01

    The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how well a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)

  4. Does caval aplanarity influence power losses across in vitro cavopulmonary connections?

    PubMed

    Gerdes, A; Hanke, T; Ahrens, V; Pfister, G; Sievers, H-H

    2002-01-01

    Optimally designed cavopulmonary connections are desirable to reduce transanastomotic power loss. Since aplanarity of the total cavopulmonary connections results from the natural anterior-posterior position of the superior vena cava and the right pulmonary artery, the aim of this study was to investigate the influence of aplanarity of caval offset on transanastomotic power losses. Two types of cavopulmonary connections, a planar cross-like connection and a nonplanar V-shaped anastomosis, were studied in a mock circulation, comparing for each type native porcine vessels and Perspex glass models. Total flow varied between 1200 and 6000 ml/min at superior to inferior caval flow ratios of SVC/IVC = 50/50% and 33/67%, respectively. Pressures and flows were measured and power losses calculated. No significant differences in power losses were found between the planar and aplanar connections for native vessels or for Perspex glass models. Power losses across the native preparations in each configuration were significantly higher than those in the corresponding Perspex glass model. The simulation of the natural aplanar V-shaped caval offset in total cavopulmonary connections used to bypass the right ventricle seems to have no relevant additional effect on in vitro power losses compared to planar connections.

  5. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2012-02-15

    We investigated the ion-loss distribution on the sidewall of an electron cyclotron resonance (ECR) plasma chamber using the 18-GHz ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex (TRIAC). Similarities and differences between the ion-loss distributions (longitudinal and azimuthal) of different ion species (i.e., radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions that are typical volatile and nonvolatile elements) was qualitatively discussed to understand the element dependence of the charge breeding efficiency. Especially, the similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  6. Analytical Limit Distributions from Random Power-Law Interactions

    NASA Astrophysics Data System (ADS)

    Zaid, Irwin; Mizuno, Daisuke

    2016-07-01

    Nature is full of power-law interactions, e.g., gravity, electrostatics, and hydrodynamics. When sources of such fields are randomly distributed in space, the superposed interaction, which is what we observe, is naively expected to follow a Gauss or Lévy distribution. Here, we present an analytic expression for the actual distributions that converge to novel limits that are in between these already-known limit distributions, depending on physical parameters, such as the concentration of field sources and the size of the probe used to measure the interactions. By comparing with numerical simulations, the origin of non-Gauss and non-Lévy distributions are theoretically articulated.

  7. The integration of renewable energy sources into electric power distribution systems. Volume 1: National assessment

    SciTech Connect

    Barnes, P.R.; Van Dyke, J.W.; Tesche, F.M.; Zaininger, H.W.

    1994-06-01

    Renewable energy technologies such as photovoltaic, solar thermal electricity, and wind turbine power are environmentally beneficial sources of electric power generation. The integration of renewable energy sources into electric power distribution systems can provide additional economic benefits because of a reduction in the losses associated with transmission and distribution lines. Benefits associated with the deferment of transmission and distribution investment may also be possible for cases where there is a high correlation between peak circuit load and renewable energy electric generation, such as photovoltaic systems in the Southwest. Case studies were conducted with actual power distribution system data for seven electric utilities with the participation of those utilities. Integrating renewable energy systems into electric power distribution systems increased the value of the benefits by about 20 to 55% above central station benefits in the national regional assessment. In the case studies presented in Vol. II, the range was larger: from a few percent to near 80% for a case where costly investments were deferred. In general, additional savings of at least 10 to 20% can be expected by integrating at the distribution level. Wind energy systems were found to be economical in good wind resource regions, whereas photovoltaic systems costs are presently a factor of 2.5 too expensive under the most favorable conditions.

  8. Economic growth, climate change, biodiversity loss: distributive justice for the global north and south.

    PubMed

    Rosales, Jon

    2008-12-01

    Economic growth-the increase in production and consumption of goods and services-must be considered within its biophysical context. Economic growth is fueled by biophysical inputs and its outputs degrade ecological processes, such as the global climate system. Economic growth is currently the principal cause of increased climate change, and climate change is a primary mechanism of biodiversity loss. Therefore, economic growth is a prime catalyst of biodiversity loss. Because people desire economic growth for dissimilar reasons-some for the increased accumulation of wealth, others for basic needs-how we limit economic growth becomes an ethical problem. Principles of distributive justice can help construct an international climate-change regime based on principles of equity. An equity-based framework that caps economic growth in the most polluting economies will lessen human impact on biodiversity. When coupled with a cap-and-trade mechanism, the framework can also provide a powerful tool for redistribution of wealth. Such an equity-based framework promises to be more inclusive and therefore more effective because it accounts for the disparate developmental conditions of the global north and south.

  9. Space station automation of common module power management and distribution

    NASA Technical Reports Server (NTRS)

    Miller, W.; Jones, E.; Ashworth, B.; Riedesel, J.; Myers, C.; Freeman, K.; Steele, D.; Palmer, R.; Walsh, R.; Gohring, J.

    1989-01-01

    The purpose is to automate a breadboard level Power Management and Distribution (PMAD) system which possesses many functional characteristics of a specified Space Station power system. The automation system was built upon 20 kHz ac source with redundancy of the power buses. There are two power distribution control units which furnish power to six load centers which in turn enable load circuits based upon a system generated schedule. The progress in building this specified autonomous system is described. Automation of Space Station Module PMAD was accomplished by segmenting the complete task in the following four independent tasks: (1) develop a detailed approach for PMAD automation; (2) define the software and hardware elements of automation; (3) develop the automation system for the PMAD breadboard; and (4) select an appropriate host processing environment.

  10. Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution

    SciTech Connect

    Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

    2010-04-30

    Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

  11. Minimization of the Ohmic Loss of Grooved Polarizer Mirrors in High-Power ECRH Systems

    NASA Astrophysics Data System (ADS)

    Wagner, D.; Leuterer, F.; Kasparek, W.; Stober, J.

    2017-02-01

    A set of two corrugated polarizer mirrors is typically used in high-power electron cyclotron resonance heating (ECRH) systems to provide the required polarization of the ECRH output beam. The ohmic losses of these mirrors can significantly exceed the losses of plane mirrors depending on the polarization of the incident beam with respect to the orientation of the grooves. Since polarizer mirrors incorporated into miter bends of a corrugated waveguide line are limited in size, active water cooling can become critical in high-power cw systems like the one for ITER. The ohmic loss of polarizer mirrors has been investigated experimentally at high power. A strategy to minimize the losses for given mirror geometries has been found.

  12. Optimal load distribution between units in a power plant.

    PubMed

    Bortoni, Edson C; Bastos, Guilherme S; Souza, Luiz E

    2007-10-01

    This paper presents a strategy for load distribution between the generating units in hydro power plants. The objective is to reach the maximum energy conversion efficiency for a given dispatched power. The developed tool employs a heuristic-based combinatorial optimization technique in conjunction with a set of system variables measurement allowing real-time load sharing. The developed equipment is used to give online energy conversion efficiency from each unit of the power plant. No specific previous information about the efficiency of system components is required. Simulation results of the proposed optimization technique when applied to typical hydro power plant data are presented.

  13. Effect of geometry and operating conditions on spur gear system power loss

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    The results of an analysis of the effects of spur gear size, pitch, width and ratio on total mesh power loss for a wide range of speeds, torques and oil viscosities are presented. The analysis uses simple algebraic expressions to determine gear sliding, rolling and windage losses and also incorporates an approximate ball bearing power loss expression. The analysis shows good agreement with published data. Large diameter and fine-pitched gears had higher peak efficiencies but lower part-load efficiency. Gear efficiencies were generally greater than 98 percent except at very low torque levels. Tare (no-load) losses are generally a significant percentage of the full-load loss except at low speeds.

  14. Optimal Operation of Energy Storage in Power Transmission and Distribution

    NASA Astrophysics Data System (ADS)

    Akhavan Hejazi, Seyed Hossein

    In this thesis, we investigate optimal operation of energy storage units in power transmission and distribution grids. At transmission level, we investigate the problem where an investor-owned independently-operated energy storage system seeks to offer energy and ancillary services in the day-ahead and real-time markets. We specifically consider the case where a significant portion of the power generated in the grid is from renewable energy resources and there exists significant uncertainty in system operation. In this regard, we formulate a stochastic programming framework to choose optimal energy and reserve bids for the storage units that takes into account the fluctuating nature of the market prices due to the randomness in the renewable power generation availability. At distribution level, we develop a comprehensive data set to model various stochastic factors on power distribution networks, with focus on networks that have high penetration of electric vehicle charging load and distributed renewable generation. Furthermore, we develop a data-driven stochastic model for energy storage operation at distribution level, where the distribution of nodal voltage and line power flow are modelled as stochastic functions of the energy storage unit's charge and discharge schedules. In particular, we develop new closed-form stochastic models for such key operational parameters in the system. Our approach is analytical and allows formulating tractable optimization problems. Yet, it does not involve any restricting assumption on the distribution of random parameters, hence, it results in accurate modeling of uncertainties. By considering the specific characteristics of random variables, such as their statistical dependencies and often irregularly-shaped probability distributions, we propose a non-parametric chance-constrained optimization approach to operate and plan energy storage units in power distribution girds. In the proposed stochastic optimization, we consider

  15. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control subsystem, volume 1

    NASA Technical Reports Server (NTRS)

    Schmeckpeper, K. R.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.

  16. The Effects of Transients on Photospheric and Chromospheric Power Distributions

    NASA Astrophysics Data System (ADS)

    Samanta, T.; Henriques, V. M. J.; Banerjee, D.; Krishna Prasad, S.; Mathioudakis, M.; Jess, D.; Pant, V.

    2016-09-01

    We have observed a quiet-Sun region with the Swedish 1 m Solar Telescope equipped with the CRISP Imaging SpectroPolarimeter. High-resolution, high-cadence, Hα line scanning images were taken to observe different layers of the solar atmosphere from the photosphere to upper chromosphere. We study the distribution of power in different period bands at different heights. Power maps of the upper photosphere and the lower chromosphere show suppressed power surrounding the magnetic-network elements, known as “magnetic shadows.” These also show enhanced power close to the photosphere, traditionally referred to as “power halos.” The interaction between acoustic waves and inclined magnetic fields is generally believed to be responsible for these two effects. In this study we explore whether small-scale transients can influence the distribution of power at different heights. We show that the presence of transients, like mottles, Rapid Blueshifted Excursions (RBEs), and Rapid Redshifted Excursions (RREs), can strongly influence the power maps. The short and finite lifetime of these events strongly affects all power maps, potentially influencing the observed power distribution. We show that Doppler-shifted transients like RBEs and RREs that occur ubiquitously can have a dominant effect on the formation of the power halos in the quiet Sun. For magnetic shadows, transients like mottles do not seem to have a significant effect on the power suppression around 3 minutes, and wave interaction may play a key role here. Our high-cadence observations reveal that flows, waves, and shocks manifest in the presence of magnetic fields to form a nonlinear magnetohydrodynamic system.

  17. 26 CFR 1.735-1 - Character of gain or loss on disposition of distributed property.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...—(1) Unrealized receivables. Any gain realized or loss sustained by a partner on a sale or exchange or... property other than a capital asset. (2) Inventory items. Any gain realized or loss sustained by a partner... partner of such inventory items after 5 years from the date of distribution shall be determined as of...

  18. Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

    SciTech Connect

    Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

    2012-07-01

    The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

  19. Forty-seventh annual power distribution conference, 1994

    SciTech Connect

    Not Available

    1994-01-01

    This is a collection of papers presented at the forty-seventh annual Power Distribution Conference in 1994. The topics of the papers include recent developments in distribution grounding, partial discharge analysis of electrical machinery, insulating fluids analysis as a basis for a complete transformer monitoring program, environmental and regulatory issues regarding the use of silicone transformer fluids, locating and identifying harmonic sources, optimizing distribution operations resources, surface launch directional boring units, electrical supply to Dallas/Fort Worth international airport, a microprocessor-based digital feeder monitor with high-impedance fault detection, a modern review of distribution system protective coordination, and Ski Apache electric service improvements.

  20. Power laws, discontinuities and regional city size distributions

    USGS Publications Warehouse

    Garmestani, A.S.; Allen, C.R.; Gallagher, C.M.

    2008-01-01

    Urban systems are manifestations of human adaptation to the natural environment. City size distributions are the expression of hierarchical processes acting upon urban systems. In this paper, we test the entire city size distributions for the southeastern and southwestern United States (1990), as well as the size classes in these regions for power law behavior. We interpret the differences in the size of the regional city size distributions as the manifestation of variable growth dynamics dependent upon city size. Size classes in the city size distributions are snapshots of stable states within urban systems in flux. ?? 2008.

  1. Markers of Inflammation and Fat Distribution following Weight Loss in African American and Caucasian Women

    PubMed Central

    Fisher, Gordon; Hyatt, Tanya C.; Hunter, Gary R.; Oster, Robert A.; Desmond, Renee A.; Gower, Barbara A.

    2013-01-01

    Changes in markers of inflammation (MOI) and fat distribution with weight loss between African American (AA) and Caucasian (C) women have yet to be characterized. The purpose of this study was to examine potential ethnic differences in MOI and regional fat distribution with weight loss, and identify the associations between these markers and changes in regional fat distribution with weight loss among AA and C women. Subjects were 126 healthy, premenopausal women, BMI 27–30 kg/m2. They were placed on a weight loss intervention consisting of diet and/or exercise until a BMI < 25 was achieved. Fat distribution was measured with computed tomography, and body composition with dual-energy X-ray absorptiometry. Serum concentrations of tumor necrosis factor (TNF)-α, soluble tumor necrosis factor receptor (sTNFR)-I, sTNFR-II, C-reactive protein (CRP), and interleukin (IL)-6 were assessed. All MOI and adiposity measures significantly decreased with weight loss. Significant ethnic differences with weight loss were observed for fat mass, body fat, intra-abdominal adipose tissue (IAAT), sTNF-RI, and sTNF-RII. Mixed-model analysis indicated that adjusting for change in IAAT explained ethnic differences in change in TNF-α and the decrease in TNF-α with weight loss, while total fat mass only explained the decrease in sTNF-RI and sTNF-RII with weight loss. In conclusion, all MOI decreased following weight loss among C, whereas only IL-6 and CRP decreased following weight loss in AA. The most distinct phenotypic difference observed was a greater impact of weight loss on TNF-α in C compared to AA, which was directly associated with IAAT in C. PMID:21527894

  2. Edge effect on the power law distribution of granular avalanches.

    PubMed

    Lorincz, Kinga A; Wijngaarden, Rinke J

    2007-10-01

    Many punctuated phenomena in nature are claimed [e.g., by the theory of self-organized criticality (SOC)] to be power-law distributed. In our experiments on a three-dimensional pile of long-grained rice, we find that by only changing the boundary condition of the system, we switch from such power-law-distributed avalanche sizes to quasiperiodic system-spanning avalanches. Conversely, by removing ledges the incidence of system-spanning avalanches is significantly reduced. This may offer a perspective on new avalanche prevention schemes. In addition, our findings may help to explain why the archetype of SOC, the sandpile, was found to have power-law-distributed avalanches in some experiments, while in other experiments quasiperiodic system-spanning avalanches were found.

  3. Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer

    PubMed Central

    Tang, Sai Chun; McDannold, Nathan J.

    2015-01-01

    This paper investigated the power losses of unsegmented and segmented energy coupling coils for wireless energy transfer. Four 30-cm energy coupling coils with different winding separations, conductor cross-sectional areas, and number of turns were developed. The four coils were tested in both unsegmented and segmented configurations. The winding conduction and intrawinding dielectric losses of the coils were evaluated individually based on a well-established lumped circuit model. We found that the intrawinding dielectric loss can be as much as seven times higher than the winding conduction loss at 6.78 MHz when the unsegmented coil is tightly wound. The dielectric loss of an unsegmented coil can be reduced by increasing the winding separation or reducing the number of turns, but the power transfer capability is reduced because of the reduced magnetomotive force. Coil segmentation using resonant capacitors has recently been proposed to significantly reduce the operating voltage of a coil to a safe level in wireless energy transfer for medical implants. Here, we found that it can naturally eliminate the dielectric loss. The coil segmentation method and the power loss analysis used in this paper could be applied to the transmitting, receiving, and resonant coils in two- and four-coil energy transfer systems. PMID:26640745

  4. Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer.

    PubMed

    Tang, Sai Chun; McDannold, Nathan J

    2015-03-01

    This paper investigated the power losses of unsegmented and segmented energy coupling coils for wireless energy transfer. Four 30-cm energy coupling coils with different winding separations, conductor cross-sectional areas, and number of turns were developed. The four coils were tested in both unsegmented and segmented configurations. The winding conduction and intrawinding dielectric losses of the coils were evaluated individually based on a well-established lumped circuit model. We found that the intrawinding dielectric loss can be as much as seven times higher than the winding conduction loss at 6.78 MHz when the unsegmented coil is tightly wound. The dielectric loss of an unsegmented coil can be reduced by increasing the winding separation or reducing the number of turns, but the power transfer capability is reduced because of the reduced magnetomotive force. Coil segmentation using resonant capacitors has recently been proposed to significantly reduce the operating voltage of a coil to a safe level in wireless energy transfer for medical implants. Here, we found that it can naturally eliminate the dielectric loss. The coil segmentation method and the power loss analysis used in this paper could be applied to the transmitting, receiving, and resonant coils in two- and four-coil energy transfer systems.

  5. Optimal reactive power planning for distribution systems considering intermittent wind power using Markov model and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Li, Cheng

    Wind farms, photovoltaic arrays, fuel cells, and micro-turbines are all considered to be Distributed Generation (DG). DG is defined as the generation of power which is dispersed throughout a utility's service territory and either connected to the utility's distribution system or isolated in a small grid. This thesis addresses modeling and economic issues pertaining to the optimal reactive power planning for distribution system with wind power generation (WPG) units. Wind farms are inclined to cause reverse power flows and voltage variations due to the random-like outputs of wind turbines. To deal with this kind of problem caused by wide spread usage of wind power generation, this thesis investigates voltage and reactive power controls in such a distribution system. Consequently static capacitors (SC) and transformer taps are introduced into the system and treated as controllers. For the purpose of getting optimum voltage and realizing reactive power control, the research proposes a proper coordination among the controllers like on-load tap changer (OLTC), feeder-switched capacitors. What's more, in order to simulate its uncertainty, the wind power generation is modeled by the Markov model. In that way, calculating the probabilities for all the scenarios is possible. Some outputs with consecutive and discrete values have been used for transition between successive time states and within state wind speeds. The thesis will describe the method to generate the wind speed time series from the transition probability matrix. After that, utilizing genetic algorithm, the optimal locations of SCs, the sizes of SCs and transformer taps are determined so as to minimize the cost or minimize the power loss, and more importantly improve voltage profiles. The applicability of the proposed method is verified through simulation on a 9-bus system and a 30-bus system respectively. At last, the simulation results indicate that as long as the available capacitors are able to sufficiently

  6. Benefits of Power Electronic Interfaces for Distributed Energy Systems

    SciTech Connect

    Kroposki, B.; Pink, C.; DeBlasio, R.; Thomas, H.; Simoes, M.; Sen, P. K.

    2006-01-01

    Optimization of overall electrical system performance is important for the long-term economic viability of distributed energy (DE) systems. With the increasing use of DE systems in industry and its technological advancement, it is becoming more important to understand the integration of these systems with the electric power systems. New markets and benefits for distributed energy applications include the ability to provide ancillary services, improve energy efficiency, enhance power system reliability, and allow customer choice. Advanced power electronic (PE) interfaces will allow DE systems to provide increased functionality through improved power quality and voltage/VAR support, increase electrical system compatibility by reducing the fault contributions, and flexibility in operations with various other DE sources, while reducing overall interconnection costs. This paper examines the system integration and optimization issues associated with DE systems and show the benefits of using PE interfaces for such applications.

  7. Power optimization of random distributed feedback fiber lasers.

    PubMed

    Vatnik, Ilya D; Churkin, Dmitry V; Babin, Sergey A

    2012-12-17

    We present a comprehensive study of power output characteristics of random distributed feedback Raman fiber lasers. The calculated optimal slope efficiency of the backward wave generation in the one-arm configuration is shown to be as high as ~90% for 1 W threshold. Nevertheless, in real applications a presence of a small reflection at fiber ends can appreciably deteriorate the power performance. The developed numerical model well describes the experimental data.

  8. Electrical Power Distribution and Control Modeling and Analysis

    NASA Technical Reports Server (NTRS)

    Fu, Johnny S.; Liffring, Mark; Mehdi, Ishaque S.

    2001-01-01

    This slide presentation reviews the use of Electrical Power Distribution and Control (EPD&C) Modeling and how modeling can support analysis. The presentation discusses using the EASY5 model to simulate and analyze the Space Shuttle Electric Auxiliary Power Unit. Diagrams of the model schematics are included, as well as graphs of the battery cell impedance, hydraulic load dynamics, and EPD&C response to hydraulic load variations.

  9. System-wide power management control via clock distribution network

    DOEpatents

    Coteus, Paul W.; Gara, Alan; Gooding, Thomas M.; Haring, Rudolf A.; Kopcsay, Gerard V.; Liebsch, Thomas A.; Reed, Don D.

    2015-05-19

    An apparatus, method and computer program product for automatically controlling power dissipation of a parallel computing system that includes a plurality of processors. A computing device issues a command to the parallel computing system. A clock pulse-width modulator encodes the command in a system clock signal to be distributed to the plurality of processors. The plurality of processors in the parallel computing system receive the system clock signal including the encoded command, and adjusts power dissipation according to the encoded command.

  10. Evaluation of power control concepts using the PMAD systems test bed. [Power Management and Distribution

    NASA Technical Reports Server (NTRS)

    Beach, R. F.; Kimnach, G. L.; Jett, T. A.; Trash, L. M.

    1989-01-01

    The Lewis Research Center's Power Management and Distribution (PMAD) System testbed and its use in the evaluation of control concepts applicable to the NASA Space Station Freedom electric power system (EPS) are described. The facility was constructed to allow testing of control hardware and software in an environment functionally similar to the space station electric power system. Control hardware and software have been developed to allow operation of the testbed power system in a manner similar to a supervisory control and data acquisition (SCADA) system employed by utility power systems for control. The system hardware and software are described.

  11. Distribution-Agnostic Stochastic Optimal Power Flow for Distribution Grids: Preprint

    SciTech Connect

    Baker, Kyri; Dall'Anese, Emiliano; Summers, Tyler

    2016-09-01

    This paper outlines a data-driven, distributionally robust approach to solve chance-constrained AC optimal power flow problems in distribution networks. Uncertain forecasts for loads and power generated by photovoltaic (PV) systems are considered, with the goal of minimizing PV curtailment while meeting power flow and voltage regulation constraints. A data- driven approach is utilized to develop a distributionally robust conservative convex approximation of the chance-constraints; particularly, the mean and covariance matrix of the forecast errors are updated online, and leveraged to enforce voltage regulation with predetermined probability via Chebyshev-based bounds. By combining an accurate linear approximation of the AC power flow equations with the distributionally robust chance constraint reformulation, the resulting optimization problem becomes convex and computationally tractable.

  12. DETERMINATION OF INVENTORIES AND POWER DISTRIBUTIONS FOR THE NSBR.

    SciTech Connect

    HANSON, A.L.; DIAMOND, D.J.

    2005-09-12

    This memo presents the details of the methodology for developing fuel inventories for the NBSR along with power distributions predicted with this set of inventories. Several improvements have been made to the MCNP model of the NBSR since a set of calculations was performed in 2002 in support of the NBSR relicensing and SAR update. One of the most significant changes in the model was to divide the fuel elements into upper and lower halves so the effects of uneven burn between the two halves (due to the shim arms) can be determined. The present set of power distributions are provided for comparison with the previous safety analyses.

  13. A Numerical Study of Water Loss Rate Distributions in MDCT-based Human Airway Models

    PubMed Central

    Wu, Dan; Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Lin, Ching-Long

    2015-01-01

    Both three-dimensional (3D) and one-dimensional (1D) computational fluid dynamics (CFD) methods are applied to study regional water loss in three multi-detector row computed-tomography (MDCT)-based human airway models at the minute ventilations of 6, 15 and 30 L/min. The overall water losses predicted by both 3D and 1D models in the entire respiratory tract agree with available experimental measurements. However, 3D and 1D models reveal different regional water loss rate distributions due to the 3D secondary flows formed at bifurcations. The secondary flows cause local skewed temperature and humidity distributions on inspiration acting to elevate the local water loss rate; and the secondary flow at the carina tends to distribute more cold air to the lower lobes. As a result, the 3D model predicts that the water loss rate first increases with increasing airway generation, and then decreases as the air approaches saturation, while the 1D model predicts a monotonic decrease of water loss rate with increasing airway generation. Moreover, the 3D (or 1D) model predicts relatively higher water loss rates in lower (or upper) lobes. The regional water loss rate can be related to the non-dimensional wall shear stress (τ*) by the non-dimensional mass transfer coefficient (h0*) as h0* = 1.15 τ*0.272, R = 0.842. PMID:25869455

  14. 26 CFR 1.735-1 - Character of gain or loss on disposition of distributed property.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... distributed property—(1) Unrealized receivables. Any gain realized or loss sustained by a partner on a sale or... by a partner on a sale or exchange of inventory items (as defined in section 751(d)(2)) received in a... partner of such inventory items after 5 years from the date of distribution shall be determined as of...

  15. Power law distribution of dividends in horse races

    NASA Astrophysics Data System (ADS)

    Park, K.; Domany, E.

    2001-02-01

    We discovered that the distribution of dividends in Korean horse races follows a power law. A simple model of betting is proposed, which reproduces the observed distribution. The model provides a mechanism to arrive at the true underlying winning probabilities, which are initially unknown, in a self-organized collective fashion, through the dynamic process of betting. Numerical simulations yield excellent agreement with the empirical data.

  16. Electric power scheduling - A distributed problem-solving approach

    NASA Technical Reports Server (NTRS)

    Mellor, Pamela A.; Dolce, James L.; Krupp, Joseph C.

    1990-01-01

    Space Station Freedom's power system, along with the spacecraft's other subsystems, needs to carefully conserve its resources and yet strive to maximize overall Station productivity. Due to Freedom's distributed design, each subsystem must work cooperatively within the Station community. There is a need for a scheduling tool which will preserve this distributed structure, allow each subsystem the latitude to satisfy its own constraints, and preserve individual value systems while maintaining Station-wide integrity.

  17. Wind Power Forecasting Error Distributions: An International Comparison; Preprint

    SciTech Connect

    Hodge, B. M.; Lew, D.; Milligan, M.; Holttinen, H.; Sillanpaa, S.; Gomez-Lazaro, E.; Scharff, R.; Soder, L.; Larsen, X. G.; Giebel, G.; Flynn, D.; Dobschinski, J.

    2012-09-01

    Wind power forecasting is expected to be an important enabler for greater penetration of wind power into electricity systems. Because no wind forecasting system is perfect, a thorough understanding of the errors that do occur can be critical to system operation functions, such as the setting of operating reserve levels. This paper provides an international comparison of the distribution of wind power forecasting errors from operational systems, based on real forecast data. The paper concludes with an assessment of similarities and differences between the errors observed in different locations.

  18. A Distributed Cooperative Power Allocation Method for Campus Buildings

    SciTech Connect

    Hao, He; Sun, Yannan; Carroll, Thomas E.; Somani, Abhishek

    2015-09-01

    We propose a coordination algorithm for cooperative power allocation among a collection of commercial buildings within a campus. We introduced thermal and power models of a typical commercial building Heating, Ventilation, and Air Conditioning (HVAC) system, and utilize model predictive control to characterize their power flexibility. The power allocation problem is formulated as a cooperative game using the Nash Bargaining Solution (NBS) concept, in which buildings collectively maximize the product of their utilities subject to their local flexibility constraints and a total power limit set by the campus coordinator. To solve the optimal allocation problem, a distributed protocol is designed using dual decomposition of the Nash bargaining problem. Numerical simulations are performed to demonstrate the efficacy of our proposed allocation method

  19. Experimental study of flow distribution and pressure loss with circumferential inlet and outlet manifolds

    NASA Technical Reports Server (NTRS)

    Dittrich, R. T.

    1972-01-01

    Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.

  20. A Wolf Pack Algorithm for Active and Reactive Power Coordinated Optimization in Active Distribution Network

    NASA Astrophysics Data System (ADS)

    Zhuang, H. M.; Jiang, X. J.

    2016-08-01

    This paper presents an active and reactive power dynamic optimization model for active distribution network (ADN), whose control variables include the output of distributed generations (DGs), charge or discharge power of energy storage system (ESS) and reactive power from capacitor banks. To solve the high-dimension nonlinear optimization model, a new heuristic swarm intelligent method, namely wolf pack algorithm (WPA) with better global convergence and computational robustness, is adapted so that the network loss minimization can be achieved. In this paper, the IEEE33-bus system is used to show the effectiveness of WPA technique compared with other techniques. Numerical tests on the modified IEEE 33-bus system show that WPA for active and reactive multi-period optimization of ADN is exact and effective.

  1. Decisions with Uncertain Consequences—A Total Ordering on Loss-Distributions

    PubMed Central

    König, Sandra; Schauer, Stefan

    2016-01-01

    Decisions are often based on imprecise, uncertain or vague information. Likewise, the consequences of an action are often equally unpredictable, thus putting the decision maker into a twofold jeopardy. Assuming that the effects of an action can be modeled by a random variable, then the decision problem boils down to comparing different effects (random variables) by comparing their distribution functions. Although the full space of probability distributions cannot be ordered, a properly restricted subset of distributions can be totally ordered in a practically meaningful way. We call these loss-distributions, since they provide a substitute for the concept of loss-functions in decision theory. This article introduces the theory behind the necessary restrictions and the hereby constructible total ordering on random loss variables, which enables decisions under uncertainty of consequences. Using data obtained from simulations, we demonstrate the practical applicability of our approach. PMID:28030572

  2. Integrated Computing, Communication, and Distributed Control of Deregulated Electric Power Systems

    SciTech Connect

    Bajura, Richard; Feliachi, Ali

    2008-09-24

    Restructuring of the electricity market has affected all aspects of the power industry from generation to transmission, distribution, and consumption. Transmission circuits, in particular, are stressed often exceeding their stability limits because of the difficulty in building new transmission lines due to environmental concerns and financial risk. Deregulation has resulted in the need for tighter control strategies to maintain reliability even in the event of considerable structural changes, such as loss of a large generating unit or a transmission line, and changes in loading conditions due to the continuously varying power consumption. Our research efforts under the DOE EPSCoR Grant focused on Integrated Computing, Communication and Distributed Control of Deregulated Electric Power Systems. This research is applicable to operating and controlling modern electric energy systems. The controls developed by APERC provide for a more efficient, economical, reliable, and secure operation of these systems. Under this program, we developed distributed control algorithms suitable for large-scale geographically dispersed power systems and also economic tools to evaluate their effectiveness and impact on power markets. Progress was made in the development of distributed intelligent control agents for reliable and automated operation of integrated electric power systems. The methodologies employed combine information technology, control and communication, agent technology, and power systems engineering in the development of intelligent control agents for reliable and automated operation of integrated electric power systems. In the event of scheduled load changes or unforeseen disturbances, the power system is expected to minimize the effects and costs of disturbances and to maintain critical infrastructure operational.

  3. Energy loss distributions of 7 TeV protons axially channeled in the bent <1 1 0> Si crystal

    NASA Astrophysics Data System (ADS)

    Stojanov, Nace; Petrović, Srdjan

    2016-04-01

    In this article, the energy loss distributions of relativistic protons axially channeled in the bent <1 1 0> Si crystal are studied. The crystal thickness is equal to 1 mm, which corresponds to the reduced crystal thickness, Λ, equal to 1.22, whereas the bending angle, α, was varied from 0 to 30 μrad. The proton energy of 7 TeV was chosen in accordance with the concept of using the bent crystals as a tool for selective deflection of the beam halo particles from the LUA9 experiment at LHC. For the continuum interaction potential of the proton and the crystal the Molière's expression was used and the energy loss of a proton was calculated by applying the trajectory dependent stopping power model. Further, the uncertainness of the scattering angle of the proton caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The energy loss distribution of the channeled protons was obtained via the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. The analysis of the obtained theoretical data shows that the shape of the energy loss distribution strongly depends on the horizontal or vertical direction of the curvature of the crystal. The number of dechanneled protons as a function of the bending angle also strongly depends on the direction of the crystal's curvature. As a result, the dechanneling rates and ranges, obtained from the Gompertz type sigmoidal fitting functions, have different sets of values for different bending orientations. We have also studied the influence of the proton beam divergence on the energy loss distribution of channeled protons.

  4. Power Management and Distribution Trades Studies for a Deep-Space Mission Scientific Spacecraft

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Soltis, James V.

    2004-01-01

    As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50kWe to one half of the ion thrusters and science modules but is capable of supplying the total power re3quirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

  5. Power Management and Distribution Trades Studies for a Deep-space Mission Scientific Spacecraft

    NASA Astrophysics Data System (ADS)

    Kimnach, Greg L.; Soltis, James V.

    2004-02-01

    As part of NASA's Project Prometheus, the Nuclear Systems Program, NASA GRC performed trade studies on the various Power Management and Distribution (PMAD) options for a deep-space scientific spacecraft, which would have a nominal electrical power requirement of 100 kWe. These options included AC (1000Hz and 1500Hz) and DC primary distribution at various voltages. The distribution system efficiency, reliability, mass, thermal, corona, space radiation levels, and technology readiness of devices and components were considered. The final proposed system consisted of two independent power distribution channels, sourced by two 3-phase, 110 kVA alternators nominally operating at half-rated power. Each alternator nominally supplies 50 kWe to one-half of the ion thrusters and science modules, but is capable of supplying the total power requirements in the event of loss of one alternator. This paper is an introduction to the methodology for the trades done to arrive at the proposed PMAD architecture. Any opinions expressed are those of the author(s) and do not necessarily reflect the views of Project Prometheus.

  6. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2004-01-01

    Advanced brush and finger seal technologies offer reduced leakage rates over conventional labyrinth seals used in gas turbine engines. To address engine manufacturers concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature Turbine Seal Test Rig. Leakage and power loss test results are compared for these competing seals for operating conditions up to 922 K (1200 F) inlet air temperature, 517 KPa (75 psid) across the seal, and surface velocities up to 366 m/s (1200 ft/s).

  7. Eddy current power loss in structural steel due to cables carrying current in a perpendicular direction

    SciTech Connect

    Namjoshi, K.V.; Lavers, J.D.; Biringer, P.P. . Dept. of Electrical and Computer Engineering)

    1994-01-01

    This paper deals with eddy current power loss in structural steel, in the vicinity of cables carrying current in a perpendicular direction. The configuration is approximated by a long cylinder perpendicular to a filament current. An analytical method is used. Expressions are provided which describe the frequency dependence of the power loss. The influence of the permeability and the physical dimensions is considered. Formulae are given for the impedance of the cylinder in different frequency regions. Numerical results are presented to show the behavior.

  8. Power-law time distribution of large earthquakes.

    PubMed

    Mega, Mirko S; Allegrini, Paolo; Grigolini, Paolo; Latora, Vito; Palatella, Luigi; Rapisarda, Andrea; Vinciguerra, Sergio

    2003-05-09

    We study the statistical properties of time distribution of seismicity in California by means of a new method of analysis, the diffusion entropy. We find that the distribution of time intervals between a large earthquake (the main shock of a given seismic sequence) and the next one does not obey Poisson statistics, as assumed by the current models. We prove that this distribution is an inverse power law with an exponent mu=2.06+/-0.01. We propose the long-range model, reproducing the main properties of the diffusion entropy and describing the seismic triggering mechanisms induced by large earthquakes.

  9. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a

  10. A Stable 0.2-THz Coaxial-Waveguide Gyrotron Traveling-Wave-Tube Amplifier with Distributed Losses

    NASA Astrophysics Data System (ADS)

    Hung, C. L.; Yeh, Y. S.; Chang, T. H.; Fang, R. S.

    2017-01-01

    For high-power operation, a THz gyrotron traveling-wave-tube (gyro-TWT) amplifier must operate in a high-order waveguide mode to enlarge the transverse dimension of an interaction waveguide. However, a gyro-TWT amplifier operating in a high-order waveguide mode is susceptible to spurious oscillations. To improve the device stability, in this study, we investigate the possibility of using a coaxial waveguide with distributed losses as the interaction structure. For the same required attenuation, all threatening oscillating modes can be suppressed using different combinations of losses of inner and outer cylinders. This provides flexibility in designing distributed losses when considering the ohmic loading of the interaction structure. We predict that the 0.2-THz gyro-TWT can stably produce a peak power of 14 kW with an efficiency of 23 %, a 3-dB bandwidth of 3.5 GHz, and a saturated gain of 50 dB for a 20-kV 3-A electron beam with a 5 % velocity spread and 1.0 velocity ratio.

  11. Emergency preparedness for power outages and wi-fi loss: tips for students and educators of online courses.

    PubMed

    Heithaus, Teresa

    2015-01-01

    Severe weather can impact online education due to a loss of power and Internet access that can last hours or weeks. Planning for such losses is essential to enable participation in the online classroom. This article discusses measures that can be used to maintain an online presence in the event of a power outage or loss of Wi-Fi.

  12. High Resolution PV Power Modeling for Distribution Circuit Analysis

    SciTech Connect

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  13. Prestorm estimation of hurricane damage to electric power distribution systems.

    PubMed

    Guikema, Seth D; Quiring, Steven M; Han, Seung-Ryong

    2010-12-01

    Hurricanes frequently cause damage to electric power systems in the United States, leading to widespread and prolonged loss of electric service. Restoring service quickly requires the use of repair crews and materials that must be requested, at considerable cost, prior to the storm. U.S. utilities have struggled to strike a good balance between over- and underpreparation largely because of a lack of methods for rigorously estimating the impacts of an approaching hurricane on their systems. Previous work developed methods for estimating the risk of power outages and customer loss of power, with an outage defined as nontransitory activation of a protective device. In this article, we move beyond these previous approaches to directly estimate damage to the electric power system. Our approach is based on damage data from past storms together with regression and data mining techniques to estimate the number of utility poles that will need to be replaced. Because restoration times and resource needs are more closely tied to the number of poles and transformers that need to be replaced than to the number of outages, this pole-based assessment provides a much stronger basis for prestorm planning by utilities. Our results show that damage to poles during hurricanes can be assessed accurately, provided that adequate past damage data are available. However, the availability of data can, and currently often is, the limiting factor in developing these types of models in practice. Opportunities for further enhancing the damage data recorded during hurricanes are also discussed.

  14. Exploring empowerment in settings: mapping distributions of network power.

    PubMed

    Neal, Jennifer Watling

    2014-06-01

    This paper brings together two trends in the empowerment literature-understanding empowerment in settings and understanding empowerment as relational-by examining what makes settings empowering from a social network perspective. Specifically, extending Neal and Neal's (Am J Community Psychol 48(3/4):157-167, 2011) conception of network power, an empowering setting is defined as one in which (1) actors have existing relationships that allow for the exchange of resources and (2) the distribution of network power among actors in the setting is roughly equal. The paper includes a description of how researchers can examine distributions of network power in settings. Next, this process is illustrated in both an abstract example and using empirical data on early adolescents' peer relationships in urban classrooms. Finally, implications for theory, methods, and intervention related to understanding empowering settings are explored.

  15. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  16. Electron beam machining using rotating and shaped beam power distribution

    DOEpatents

    Elmer, J.W.; O`Brien, D.W.

    1996-07-09

    An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.

  17. Distributed Power Flow Control: Distributed Power Flow Control using Smart Wires for Energy Routing

    SciTech Connect

    2012-04-24

    GENI Project: Smart Wire Grid is developing a solution for controlling power flow within the electric grid to better manage unused and overall transmission capacity. The 300,000 miles of high-voltage transmission line in the U.S. today are congested and inefficient, with only around 50% of all transmission capacity utilized at any given time. Increased consumer demand should be met in part with more efficient and an economical power flow. Smart Wire Grid’s devices clamp onto existing transmission lines and control the flow of power within—much like how internet routers help allocate bandwidth throughout the web. Smart wires could support greater use of renewable energy by providing more consistent control over how that energy is routed within the grid on a real-time basis. This would lessen the concerns surrounding the grid’s inability to effectively store intermittent energy from renewables for later use.

  18. HEMP interaction with an electric power distribution circuit. Final report

    SciTech Connect

    Zaininger, H.W.; Jaszewski, G.M.

    1985-08-01

    A high altitude nuclear burst, detonated at a height of 50 km or more, causes two types of electromagnetic pulses, high altitude EMP (HEMP) and magnetohydrodynamic EMP, which will interact with electric power systems. Previous work indicated that millions of miles of electric distribution systems in the United States may be especially vulnerable to HEMP incident simultaneously throughout large portions of the United States. Purpose of this work was to perform an initial assessment of HEMP induced surges on a simplified electric distribution system. This report presents the assumptions, methodology, and resulting induced transient voltages and currents at various points in the distribution circuit in the microsecond timeframe, considering the impacts of HEMP incident simultaneously throughout the distribution system for a range of parametric conditions. Results of this work suggest that EMP could induce voltage transients that far exceed the basic insulation level (BIL) of distribution systems and that a more detailed analysis is warranted.

  19. Learning geotemporal nonstationary failure and recovery of power distribution.

    PubMed

    Wei, Yun; Ji, Chuanyi; Galvan, Floyd; Couvillon, Stephen; Orellana, George; Momoh, James

    2014-01-01

    Smart energy grid is an emerging area for new applications of machine learning in a nonstationary environment. Such a nonstationary environment emerges when large-scale failures occur at power networks because of external disruptions such as hurricanes and severe storms. Power distribution networks lie at the edge of the grid, and are especially vulnerable to external disruptions. Quantifiable approaches are lacking and needed to learn nonstationary behaviors of large-scale failure and recovery of power distribution. This paper studies such nonstationary behaviors in three aspects. First, a novel formulation is derived for an entire life cycle of large-scale failure and recovery of power distribution. Second, spatial-temporal models of failure and recovery of power distribution are developed as geolocation-based multivariate nonstationary GI(t)/G(t)/∞ queues. Third, the nonstationary spatial-temporal models identify a small number of parameters to be learned. Learning is applied to two real-life examples of large-scale disruptions. One is from Hurricane Ike, where data from an operational network is exact on failures and recoveries. The other is from Hurricane Sandy, where aggregated data is used for inferring failure and recovery processes at one of the impacted areas. Model parameters are learned using real data. Two findings emerge as results of learning: 1) failure rates behave similarly at the two different provider networks for two different hurricanes but differently at the geographical regions and 2) both the rapid and slow-recovery are present for Hurricane Ike but only slow recovery is shown for a regional distribution network from Hurricane Sandy.

  20. Multi-kw dc power distribution system study program

    NASA Technical Reports Server (NTRS)

    Berkery, E. A.; Krausz, A.

    1974-01-01

    The first phase of the Multi-kw dc Power Distribution Technology Program is reported and involves the test and evaluation of a technology breadboard in a specifically designed test facility according to design concepts developed in a previous study on space vehicle electrical power processing, distribution, and control. The static and dynamic performance, fault isolation, reliability, electromagnetic interference characterisitics, and operability factors of high distribution systems were studied in order to gain a technology base for the use of high voltage dc systems in future aerospace vehicles. Detailed technical descriptions are presented and include data for the following: (1) dynamic interactions due to operation of solid state and electromechanical switchgear; (2) multiplexed and computer controlled supervision and checkout methods; (3) pulse width modulator design; and (4) cable design factors.

  1. Using Reanalysis Data for the Prediction of Seasonal Wind Turbine Power Losses Due to Icing

    NASA Astrophysics Data System (ADS)

    Burtch, D.; Mullendore, G. L.; Delene, D. J.; Storm, B.

    2013-12-01

    The Northern Plains region of the United States is home to a significant amount of potential wind energy. However, in winter months capturing this potential power is severely impacted by the meteorological conditions, in the form of icing. Predicting the expected loss in power production due to icing is a valuable parameter that can be used in wind turbine operations, determination of wind turbine site locations and long-term energy estimates which are used for financing purposes. Currently, losses due to icing must be estimated when developing predictions for turbine feasibility and financing studies, while icing maps, a tool commonly used in Europe, are lacking in the United States. This study uses the Modern-Era Retrospective Analysis for Research and Applications (MERRA) dataset in conjunction with turbine production data to investigate various methods of predicting seasonal losses (October-March) due to icing at two wind turbine sites located 121 km apart in North Dakota. The prediction of icing losses is based on temperature and relative humidity thresholds and is accomplished using three methods. For each of the three methods, the required atmospheric variables are determined in one of two ways: using industry-specific software to correlate anemometer data in conjunction with the MERRA dataset and using only the MERRA dataset for all variables. For each season, a percentage of the total expected generated power lost due to icing is determined and compared to observed losses from the production data. An optimization is performed in order to determine the relative humidity threshold that minimizes the difference between the predicted and observed values. Eight seasons of data are used to determine an optimal relative humidity threshold, and a further three seasons of data are used to test this threshold. Preliminary results have shown that the optimized relative humidity threshold for the northern turbine is higher than the southern turbine for all methods

  2. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  3. Improving Advanced Inverter Control Convergence in Distribution Power Flow

    SciTech Connect

    Nagarajan, Adarsh; Palmintier, Bryan; Ding, Fei; Mather, Barry; Baggu, Murali

    2016-11-21

    Simulation of modern distribution system powerflow increasingly requires capturing the impact of advanced PV inverter voltage regulation on powerflow. With Volt/var control, the inverter adjusts its reactive power flow as a function of the point of common coupling (PCC) voltage. Similarly, Volt/watt control curtails active power production as a function of PCC voltage. However, with larger systems and higher penetrations of PV, this active/reactive power flow itself can cause significant changes to the PCC voltage potentially introducing oscillations that slow the convergence of system simulations. Improper treatment of these advanced inverter functions could potentially lead to incorrect results. This paper explores a simple approach to speed such convergence by blending in the previous iteration's reactive power estimate to dampen these oscillations. Results with a single large (5MW) PV system and with multiple 500kW advanced inverters show dramatic improvements using this approach.

  4. Multi-Code Ab Initio Calculation of Ionization Distributions and Radiation Losses for Tungsten in Tokamak Plasmas

    SciTech Connect

    Ralchenko, Yu.; Abdallah, J. Jr.; Colgan, J.; Fontes, C. J.; Foster, M.; Zhang, H. L.; Bar-Shalom, A.; Oreg, J.; Bauche, J.; Bauche-Arnoult, C.; Bowen, C.; Faussurier, G.; Chung, H.-K.; Hansen, S. B.; Lee, R. W.; Scott, H.; Gaufridy de Dortan, F. de; Poirier, M.; Golovkin, I.; Novikov, V.

    2009-09-10

    We present calculations of ionization balance and radiative power losses for tungsten in magnetic fusion plasmas. The simulations were performed within the framework of Non-Local Thermodynamic Equilibrium (NLTE) Code Comparison Workshops utilizing several independent collisional-radiative models. The calculations generally agree with each other; however, a clear disagreement with experimental ionization distributions at low temperatures 2 keV

  5. Chattanooga Electric Power Board Case Study Distribution Automation

    SciTech Connect

    Glass, Jim; Melin, Alexander M.; Starke, Michael R.

    2016-10-01

    In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities considering a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under

  6. Emissivity-corrected power loss calibration for lock-in thermography measurements on silicon solar cells

    SciTech Connect

    Kasemann, Martin; Walter, Benjamin; Meinhardt, Christoph; Ebser, Jan; Kwapil, Wolfram; Warta, Wilhelm

    2008-06-01

    This paper describes power loss calibration procedures with implemented emissivity correction. The determination of our emissivity correction matrix does neither rely on blackbody reference measurements nor on the knowledge of any sample temperatures. To describe the emissivity-corrected power calibration procedures in detail, we review the theory behind lock-in thermography and show experimentally that the lock-in signal is proportional to the power dissipation in the solar cell. Experiments show the successful application of our emissivity correction procedure, which significantly improves the informative value of lock-in thermography images and the reliability of the conclusions drawn from these images.

  7. Distributed renewable power from biomass and other waste fuels

    NASA Astrophysics Data System (ADS)

    Lyons, Chris

    2012-03-01

    The world population is continually growing and putting a burden on our fossil fuels. These fossil fuels such as coal, oil and natural gas are used for a variety of critical needs such as power production and transportation. While significant environmental improvements have been made, the uses of these fuels are still causing significant ecological impacts. Coal power production efficiency has not improved over the past thirty years and with relatively cheap petroleum cost, transportation mileage has not improved significantly either. With the demand for these fossil fuels increasing, ultimately price will also have to increase. This presentation will evaluate alternative power production methods using localized distributed generation from biomass, municipal solid waste and other waste sources of organic materials. The presentation will review various gasification processes that produce a synthetic gas that can be utilized as a fuel source in combustion turbines for clean and efficient combined heat and power. This fuel source can produce base load renewable power. In addition tail gases from the production of bio-diesel and methanol fuels can be used to produce renewable power. Being localized can reduce the need for long and costly transmission lines making the production of fuels and power from waste a viable alternative energy source for the future.

  8. About Losses in Pumping Generators of High-Power Electrodischarge Excimer Lasers

    NASA Astrophysics Data System (ADS)

    Ivanov, N. G.; Losev, V. F.

    2015-04-01

    Energy losses in pumping systems of discharge high-power lasers are investigated. To estimate the losses, the discharge circuit operation was modeled, and its calculation was performed using the program PSpice. Results of measurements and calculations demonstrate that the resistance of a rail gap with electric field distortion exceeds several times the resistance of a single-channel gap without field distortion. A difference in the resistances is explained by different mechanisms of discharge burning: in the first case diffusion mechanism and in the second case the spark mechanism. The low efficiency of the high-power excimer lasers (~1%) is explained by high energy losses in the rail gap that reach more than 50% of the initially stored energy.

  9. Analysis on heat loss characteristics of a 10 kV HTS power substation

    NASA Astrophysics Data System (ADS)

    Teng, Yuping; Dai, Shaotao; Song, Naihao; Zhang, Jingye; Gao, Zhiyuan; Zhu, Zhiqin; Zhou, Weiwei; Wei, Zhourong; Lin, Liangzhen; Xiao, Liye

    2014-09-01

    A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

  10. Theoretical study of pump power distribution on modal instabilities in high power fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Tao, Rumao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Liu, Zejin

    2017-02-01

    Influence of pump power distribution on modal instabilities (MI) is studied numerically, which reveals that the MI threshold is dependent on the pump power distribution in fiber amplifiers and can be increased by optimizing the pump power distribution without any adjustment of other amplifier parameters. It shows that amplifiers with backward or bi-direction pump schemes have a higher threshold than those employing forward pump schemes. For backward pumped amplifiers employing fiber with core/clad diameter being 20/400 µm, the MI threshold yields a 42% increase compared to the forward pumped ones. For bi-direction pumped amplifiers, there exists an optimal power ratio between forward and backward pump power, which results in the highest threshold power. When amplifiers with core/clad diameter being 20/400 µm employ a bi-direction pump scheme at the optimal backward pump power fraction, the threshold can be increased by a factor of approximately 60% with respect to the forward pump configuration. The threshold increment factor reduces as the gain saturation effect weakens. It also shows that the MI threshold can be increased by employing multi-point side pump schemes.

  11. Development of a bionanobattery for distributed power storage systems

    NASA Astrophysics Data System (ADS)

    King, Glen C.; Choi, Sang H.; Chu, Sang-Hyon; Kim, Jae-Woo; Park, Yeonjoon; Lillehei, Peter T.; Watt, Gerald D.; Davis, Robert C.; Harb, John N.

    2004-07-01

    Currently available power storage systems, such as those used to supply power to microelectronic devices, typically consist of a single centralized canister and a series of wires to supply electrical power to where it is needed in a circuit. As the size of electrical circuits and components become smaller, there exists a need for a distributed power system to reduce Joule heating, wiring, and to allow autonomous operation of the various functions performed by the circuit. Our research is being conducted to develop a bio-nanobattery using ferritins reconstituted with both an iron core (Fe-ferritin) and a cobalt core (Co-ferritin). Both Co-ferritin and Fe-ferritin were synthesized and characterized as candidates for the bio-nanobattery. The reducing capability was determined as well as the half-cell electrical potentials, indicating an electrical output of nearly 0.5 V for the battery cell. Ferritins having other metallic cores are also being investigated, in order to increase the overall electrical output. Two dimensional ferritin arrays were also produced on various substrates, demonstrating the necessary building blocks for the bio-nanobattery. The bio-nanobattery will play a key role in moving to a distributed power storage system for electronic applications.

  12. Deviation from power law of the global seismic moment distribution

    NASA Astrophysics Data System (ADS)

    Serra, Isabel; Corral, Álvaro

    2017-01-01

    The distribution of seismic moment is of capital interest to evaluate earthquake hazard, in particular regarding the most extreme events. We make use of likelihood-ratio tests to compare the simple Gutenberg-Richter power-law (PL) distribution with two statistical models that incorporate an exponential tail, the so-called tapered Gutenberg-Richter (Tap) and the truncated gamma, when fitted to the global CMT earthquake catalog. Although the Tap distribution does not introduce any significant improvement of fit respect the PL, the truncated gamma does. Simulated samples of this distribution, with parameters β = 0.68 and mc = 9.15 and reshuffled in order to mimic the time occurrence of the order statistics of the empirical data, are able to explain the temporal heterogeneity of global seismicity both before and after the great Sumatra-Andaman earthquake of 2004.

  13. Deviation from power law of the global seismic moment distribution

    PubMed Central

    Serra, Isabel; Corral, Álvaro

    2017-01-01

    The distribution of seismic moment is of capital interest to evaluate earthquake hazard, in particular regarding the most extreme events. We make use of likelihood-ratio tests to compare the simple Gutenberg-Richter power-law (PL) distribution with two statistical models that incorporate an exponential tail, the so-called tapered Gutenberg-Richter (Tap) and the truncated gamma, when fitted to the global CMT earthquake catalog. Although the Tap distribution does not introduce any significant improvement of fit respect the PL, the truncated gamma does. Simulated samples of this distribution, with parameters β = 0.68 and mc = 9.15 and reshuffled in order to mimic the time occurrence of the order statistics of the empirical data, are able to explain the temporal heterogeneity of global seismicity both before and after the great Sumatra-Andaman earthquake of 2004. PMID:28053311

  14. Power management and distribution considerations for a lunar base

    NASA Technical Reports Server (NTRS)

    Kenny, Barbara H.; Coleman, Anthony S.

    1991-01-01

    Design philosophies and technology needs for the power management and distribution (PMAD) portion of a lunar base power system are discussed. A process is described whereby mission planners may proceed from a knowledge of the PMAD functions and mission performance requirements to a definition of design options and technology needs. Current research efforts at the NASA LRC to meet the PMAD system needs for a Lunar base are described. Based on the requirements, the lunar base PMAD is seen as best being accomplished by a utility like system, although with some additional demands including autonomous operation and scheduling and accurate, predictive modeling during the design process.

  15. Cleaning ability and induced dentin loss of a magnetostrictive ultrasonic instrument at different power settings.

    PubMed

    Lampe Bless, Kathrin; Sener, Beatrice; Dual, Jürg; Attin, Thomas; Schmidlin, Patrick R

    2011-04-01

    Some laboratory studies have evaluated the oscillation mode of ultrasonic scalers. None of them recorded its influence on calculus removal and quantified dental hard tissue loss. This study aimed to compare the performance of a magnetostrictive ultrasonic instrument at different power settings in vitro in relation to the tip oscillation activity. The oscillation activity of the straight Slimline® insert in the Cavitron® ultrasonic scaling device was analyzed at five different power settings with the help of two laser vibrometers. The performance of this instrument was tested on 60 roots of human single-rooted teeth. Twelve roots each were randomly assigned to be instrumented at a given power setting. Every root was instrumented for 120 s at a standardized instrumentation force of 0.1 ± 0.05 N. In addition, another 30 periodontally involved roots with subgingival calculus were instrumented accordingly to assess the calculus removal potential. The surface characteristics after instrumentation were analyzed under scanning electron microscope. The instrumentation at minimum power setting resulted in an mean increase of the root surface roughness of 0.18 ± 0.28 compared to 0.51 ± 0.48 at maximum power setting (P = 0.0327). The loss of dental hard tissue amounted to 11.37 ± 3.64 at minimum compared to 23.37 ± 15.76 at maximum power (P = 0.0010). The higher the power setting, the more calculus was removed. The values of the latter ranged between 4.04 ± 1.87 and 11.26 ± 4.66 mm² of cleaned dentin surface area (P = 0.0065). At lower power settings, a more favorable relation between cleaning ability, loss of dentine, and surface roughness was found.

  16. An estimation method of the fault wind turbine power generation loss based on correlation analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Tao; Zhu, Shourang; Wang, Wei

    2017-01-01

    A method for estimating the power generation loss of a fault wind turbine is proposed in this paper. In this method, the wind speed is estimated and the estimated value of the loss of power generation is given by combining the actual output power characteristic curve of the wind turbine. In the wind speed estimation, the correlation analysis is used, and the normal operation of the wind speed of the fault wind turbine is selected, and the regression analysis method is used to obtain the estimated value of the wind speed. Based on the estimation method, this paper presents an implementation of the method in the monitoring system of the wind turbine, and verifies the effectiveness of the proposed method.

  17. Modeling turbine wakes and power losses within the Horns Rev offshore wind farm using large-eddy simulation

    NASA Astrophysics Data System (ADS)

    Wu, Yu-Ting; Porte-Agel, Fernando

    2013-04-01

    A recently-developed large-eddy simulations (LES) framework is implemented to predict multiple wake flows and the associated power losses within the Horns Rev offshore wind farm under near-neutral stability conditions. A tuning-free Lagrangian scale-dependent dynamic subgrid-scale (SGS) model is used for the parametrization of the SGS stresses. The turbine-generated power outputs and the turbine-induced forces (e.g., thrust, lift, drag) are parameterized using two models: (a) the traditional actuator-disk model without rotation (ADM-NR), which uses the 1D momentum theory to relate the power output and the thrust force with a representative velocity over the rotor (e.g., the disk-averaged velocity); and (b) the actuator-disk model with rotation (ADM-R), which adopts blade element theory to calculate the lift and drag forces (that produce thrust, rotor shaft torque, and power) based on the local blade and flow characteristics. In general, the predicted power outputs obtained using the ADM-R are in good agreement with observed power data from the Horns Rev wind farm. The ADM-NR tends to underestimate the power output. A similar under-prediction is obtained using industry-standard wind-farm models such as the Wind Atlas Analysis and Application Program (WAsP). Simulations using different inflow conditions show that the mean wind direction has a strong effect on the spatial distributions of the time-averaged velocity and the turbulence intensity within the farm. These, in turn, affect the power output and the fatigue loads on the turbines. When the prevailing wind direction is parallel to the turbine rows (i.e., a full wake condition), the velocity deficit and the power losses are largest, and the turbulence intensity levels are highest and have a symmetric pattern (dual-peak at hub height) on both sides of the turbine wakes. A detailed analysis of the turbulence kinetic energy budget in the full wake condition shows an important effect of the increased turbulence level

  18. Power distribution for an Am/Cm bushing melter

    SciTech Connect

    Gong, C.; Hardy, B.J.

    1996-12-31

    Decades of nuclear material production at the Savannah River Site (SRS) has resulted in the generation of large quantities of the isotopes Am{sup 243} and Cm{sup 244}. Currently, the Am and Cm isotopes are stored as a nitric acid solution in a tank. The Am and Cm isotopes have great commercial value but must be transferred to ORNL for processing. The nitric acid solution contains other isotopes and is intensely radioactive, which makes storage a problem and precludes shipment in the liquid form. In order to stabilize the material for onsite storage and to permit transport the material from SRS to ORNL, it has been proposed that the Am and Cm be separated from other isotopes in the solution and vitrified. Vitrification will be effected by depositing a liquid feed stream containing the isotopes in solution, together with a stream of glass frit, onto the top of a molten glass pool in a melter. The glass is non-conducting and the melter is a Platinum/Rhodium alloy vessel which is heated by passing an electric current through it. Because most of the power is required to evaporate the liquid feed at the top of the glass pool, power demands differ for the upper and lower parts of the melter. In addition, the melter is batch fed so that the local power requirements vary with time. In order to design a unique split power supply, which ensures adequate local power delivery, an analysis of the melter power distribution was performed with the ABAQUS finite element code. ABAQUS was used to calculate the electric potential and current density distributions in the melter for a variety of current and potential boundary conditions. The results of the calculation were compared with test data and will be used to compute power densities for input to a computational fluid dynamics model for the melter.

  19. Advanced power supply and distribution systems for Columbus

    NASA Astrophysics Data System (ADS)

    Eggers, Gert

    1988-01-01

    The paper describes power supply and distribution systems to be used on unmanned/man-tended Columbus elements, capable of supplying 10 kW to 30 kW to a variety of users in low earth orbits (LEO's). For the definition of the Electrical Power System (EPS) challenging requirements as the provision of high power levels under hard LEO conditions, maintainability, commonality etc. are to be taken into account. These requirements are to be seen in conjunction with the Columbus IOC (initial operational capability) scenario stipulating that EPS hardware shall be used on the Polar Platform, the Pressurized Module attached to the U.S. Space Station and the Man-Tended Free Flier. According to the availability of European technologies, the baseline in the power generation area is a photovoltaic system which provides three regulated main buses (150 V d.c.) to the users. In order to maintain power supply during eclipse phases, nickel hydrogen batteries will be used for energy storage purposes with nickel cadmium as back-up solution. The power distribution system needs special attention. Due to the elevated voltage levels mechanical switch gear cannot be used any longer. It is to be replaced by solid state power controllers (SSPC). Because these devices show a totally different behaviour with regard to conventional relay contacts, new approaches in the area of switching and protection are necessary. In view of the crucial role of this new technology for the realization of medium voltage d.c. systems, it is of great importance for Columbus and, hence will receive adequate consideration in the paper. In order to cater for effective management and control of the power supply and distribution hardware, a so called power system internal data processing assembly (PINDAP) has been introduced in the EPS. PINDAP is the key to reduced dependence on ground stations (alleviated ground support requirements); it keeps crew involvement in the EPS control process to as minimum and provides

  20. Power system distributed oscilation detection based on Synchrophasor data

    NASA Astrophysics Data System (ADS)

    Ning, Jiawei

    Along with increasing demand for electricity, integration of renewable energy and deregulation of power market, power industry is facing unprecedented challenges nowadays. Within the last couple of decades, several serious blackouts have been taking place in United States. As an effective approach to prevent that, power system small signal stability monitoring has been drawing more interests and attentions from researchers. With wide-spread implementation of Synchrophasors around the world in the last decade, power systems real-time online monitoring becomes much more feasible. Comparing with planning study analysis, real-time online monitoring would benefit control room operators immediately and directly. Among all online monitoring methods, Oscillation Modal Analysis (OMA), a modal identification method based on routine measurement data where the input is unmeasured ambient excitation, is a great tool to evaluate and monitor power system small signal stability. Indeed, high sampling Synchrophasor data around power system is fitted perfectly as inputs to OMA. Existing methods in OMA for power systems are all based on centralized algorithms applying at control centers only; however, with rapid growing number of online Synchrophasors the computation burden at control centers is and will be continually exponentially expanded. The increasing computation time at control center compromises the real-time feature of online monitoring. The communication efforts between substation and control center will also be out of reach. Meanwhile, it is difficult or even impossible for centralized algorithms to detect some poorly damped local modes. In order to avert previous shortcomings of centralized OMA methods and embrace the new changes in the power systems, two new distributed oscillation detection methods with two new decentralized structures are presented in this dissertation. Since the new schemes brought substations into the big oscillation detection picture, the proposed

  1. Synthesis of a low loss Mn-Zn ferrite for power applications

    NASA Astrophysics Data System (ADS)

    Tsakaloudi, Vasiliki; Zaspalis, Vassilios

    2016-02-01

    Current market trends of the switching power supplies industry require even lower energy losses in power conversion systems with maintenance of satisfactory initial permeability levels. Typical operation conditions refer to a frequency of 100 kHz, an induction level of 200 mT and a steady state temperature of 100° C. In this work the development of a polycrystalline Mn-Zn ferrite material that exhibits initial relative magnetic permeability above 2500 and very low power losses at 100 kHz, 200 mmT and 100° C is presented. The Mn-Zn ferrite samples were prepared by the conventional solid state reaction method. Sintering was performed under controlled atmosphere conditions. The combinatorial role of TiO2 and CoO together with Zn content, as well as the effects of the process parameters on the magnetic performance of the Mn-Zn ferrite was evaluated. It is shown that the development of the adequate polycrystalline microstructure that is characterized by (a) high sintered density, (b) homogenous grain size that is free of morphological or chemical pinning defects and (c) high resistivity grain boundary structure, can be achieved by means of appropriate compositional and dopant adjustment, anisotropy control and specific resistivity optimization. The newly developed Mn-Zn ferrite is characterized by high sintered density of 4.91 g/cm3, initial magnetic permeability of 2512 (at 10 kHz, 0.1 mT, 25 °C), high saturation magnetic flux density of 560 mT (at 10 kHz, 1200 A/m, 25 °C) and very low power losses (Pv) of 224 mW/cm3 (at 100 kHz, 200 mT, 100 °C) combined with very low power losses of 470 mW/cm3 even at room temperature, establishing it as ideal for power applications.

  2. Distributed Optimal Generation Control of Shipboard Power Systems

    DTIC Science & Technology

    2012-05-01

    address the needs of SPSs, a fully-distributed, multi - agent system (MAS)-based solution is proposed to optimize the control references of distributed...Transactions on Power Systems, Vol.27, No.1, pp.233-242, Feb. 2012. [4] J. M. Solanki and N. N. Schulz, “Using intelligent multi - agent systems for shipboard...D 2005/2006, pp. 562-567, May 21-24, 2006. [11] J. A. Momoh, K. Alfred and Y. Xia, “Framework for Multi - Agent System (MAS) Detection and Control

  3. Distributed Optimal Generation Control of Shipboard Power Systems

    DTIC Science & Technology

    2012-05-01

    address the needs of SPSs, a fully-distributed, multi - agent system (MAS)-based solution is proposed to optimize the control references of distributed...Systems, Vol.27, No.1, pp.233-242, Feb. 2012. [4] J. M. Solanki and N. N. Schulz, “Using intelligent multi - agent systems for shipboard power...pp. 562-567, May 21-24, 2006. [11] J. A. Momoh, K. Alfred and Y. Xia, “Framework for Multi - Agent System (MAS) Detection and Control of Arcing of

  4. Electric power scheduling: A distributed problem-solving approach

    NASA Technical Reports Server (NTRS)

    Mellor, Pamela A.; Dolce, James L.; Krupp, Joseph C.

    1990-01-01

    Space Station Freedom's power system, along with the spacecraft's other subsystems, needs to carefully conserve its resources and yet strive to maximize overall Station productivity. Due to Freedom's distributed design, each subsystem must work cooperatively within the Station community. There is a need for a scheduling tool which will preserve this distributed structure, allow each subsystem the latitude to satisfy its own constraints, and preserve individual value systems while maintaining Station-wide integrity. The value-driven free-market economic model is such a tool.

  5. Power loss characteristics of a sensing element based on a polymer optical fiber under cyclic tensile elongation.

    PubMed

    Chen, Yung-Chuan; Chen, Li-Wen; Lu, Wei-Hua

    2011-01-01

    In this study, power losses in polymer optical fiber (POF) subjected to cyclic tensile loadings are studied experimentally. The parameters discussed are the cyclic load level and the number of cycles. The results indicate that the power loss in POF specimens increases with increasing load level or number of cycles. The power loss can reach as high as 18.3% after 100 cyclic loadings. Based on the experimental results, a linear equation is proposed to estimate the relationship between the power loss and the number of cycles. The difference between the estimated results and the experimental results is found to be less than 3%.

  6. Optimal Power Flow for Distribution Systems under Uncertain Forecasts

    SciTech Connect

    Dall'Anese, Emiliano; Baker, Kyri; Summers, Tyler

    2016-12-29

    The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

  7. Power-law distribution in Japanese racetrack betting

    NASA Astrophysics Data System (ADS)

    Ichinomiya, Takashi

    2006-08-01

    Gambling is one of the basic economic activities that humans indulge in. An investigation of gambling activities provides deep insights into the economic actions of people and sheds lights on the study of econophysics. In this paper we present an analysis of the distribution of the final odds of the races organized by the Japan Racing Association. The distribution of the final odds Po(x) indicates a clear power-law Po(x)∝1/x, where x represents the final odds. This power-law can be explained on the basis of the assumption that every bettor bets his money on the horse that appears to be the strongest in a race.

  8. Optimal Power Flow for Distribution Systems under Uncertain Forecasts: Preprint

    SciTech Connect

    Dall'Anese, Emiliano; Baker, Kyri; Summers, Tyler

    2016-12-01

    The paper focuses on distribution systems featuring renewable energy sources and energy storage devices, and develops an optimal power flow (OPF) approach to optimize the system operation in spite of forecasting errors. The proposed method builds on a chance-constrained multi-period AC OPF formulation, where probabilistic constraints are utilized to enforce voltage regulation with a prescribed probability. To enable a computationally affordable solution approach, a convex reformulation of the OPF task is obtained by resorting to i) pertinent linear approximations of the power flow equations, and ii) convex approximations of the chance constraints. Particularly, the approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive optimization strategy is then obtained by embedding the proposed OPF task into a model predictive control framework.

  9. Distributed Electrical Power Generation: Summary of Alternative Available Technologies

    DTIC Science & Technology

    2003-09-01

    Technical Report (TR)-01-18, ADA388687. Borbely, Ann-Marie and Jan F. Kreider. 2001. Dis ributed Genera on: The Power Paradigm for the New...Construction Engineering Research Laboratory PO Box 9005 Champaign, IL 61826-9005 Final Report Approved for public release; distribution is...are provided. DISCLAIMER: The contents of this report are not to be used for advertising, publication, or promotional purposes. Citation of trade

  10. Signal losses with real-time three-dimensional power Doppler imaging.

    PubMed

    Garcia, Damien; Fenech, Marianne; Qin, Zhao; Soulez, Gilles; Cloutier, Guy

    2007-10-01

    Power Doppler imaging (PDI) has been shown to be influenced by the wall filter when assessing arterial stenoses. Real-time 3-D Doppler imaging may likely become a widespread practice in the near future, but how the wall filter could affect PDI during the cardiac cycle has not been investigated. The objective of the study was to demonstrate that the wall filter may produce unexpected major signal losses in real-time 3-D PDI. To test our hypothesis, we first validated binary images obtained from analytical simulations with in vitro PDI acquisitions performed in a tube under pulsatile flow conditions. We then simulated PDI images in the presence of a severe stenosis, considering physiological conditions by finite element modeling. Power Doppler imaging simulations revealed important signal losses within the lumen area at different instants of the flow cycle, and there was a very good concordance between measured and predicted PDI binary images in the tube. Our results show that the wall filter may induce severe PDI signal losses that could negatively influence the assessment of vascular stenosis. Clinicians should therefore be aware of this cause of signal loss to properly interpret power Doppler angiographic images.

  11. High-power and narrow-linewidth tunable distributed-reflector laser

    NASA Astrophysics Data System (ADS)

    Kaneko, Toshimitsu; Matsuura, Hiroyuki; Tanizawa, Ken; Uesaka, Katsumi

    2016-02-01

    Deployment of digital coherent transmission technologies to metro networks drives the use of higher-order modulation formats such as PDM-16QAM and downsizing of optical transceivers. A narrow-linewidth (<300 kHz) tunable laser with high output power (>+17 dBm) is very attractive for such purposes, not only because it can compensate for the modulation loss increase caused by a high-peak-to-average ratio of the electrical driving signal of higher-order modulation formats, but also because it can be shared between transmitter and receiver saving the foot-print and power dissipation. This paper reviews the Tunable Distributed Amplification -- Chirped Sampled Grating -- Distributed Reflector (TDA-CSG-DR) laser being developed for metro application.

  12. Distributed Solar Photovoltaic Power Production - Technology and Benefits

    SciTech Connect

    Matos, Al; Stuby, Rick

    2011-11-02

    As part of its nationally recognized Solar 4 All program, PSE&G has partnered with Petra Solar to deploy the world’s first and largest pole attached solar project. The project, based on Petra Solar’s distributed Smart Solar solution, will create a 40 megawatt solar “virtual power plant.” In deployment as 200,000 individual grid-connected solar power producers on utility poles in PSE&G territory, Petra Solar SunWave® solutions leverage Smart Grid communications and high-tech panel-level inverters to implement a robust system with many technical benefits over traditional solar photovoltaic solutions. The program overview, deployment model, smart grid communications and enabling inverter technology and safety features will be presented, as well the future challenges of, and solutions for, solar power intermittency as photovoltaic penetration on the electric grid increases.

  13. Assessment of distributed solar power systems: Issues and impacts

    NASA Astrophysics Data System (ADS)

    Moyle, R. A.; Chernoff, H.; Schweizer, T. C.; Patton, J. B.

    1982-11-01

    The installation of distributed solar-power systems presents electric utilities with a host of questions. Some of the technical and economic impacts of these systems are discussed. Among the technical interconnect issues are isolated operation, power quality, line safety, and metering options. Economic issues include user purchase criteria, structures and installation costs, marketing and product distribution costs, and interconnect costs. An interactive computer program that allows easy calculation of allowable system prices and allowable generation-equipment prices was developed as part of this project. It is concluded that the technical problems raised by distributed solar systems are surmountable, but their resolution may be costly. The stringent purchase criteria likely to be imposed by many potential system users and the economies of large-scale systems make small systems (less than 10 to 20 kW) less attractive than larger systems. Utilities that consider life-cycle costs in making investment decisions and third-party investors who have tax and financial advantages are likely to place the highest value on solar-power systems.

  14. Power Management and Distribution (PMAD) Model Development: Final Report

    NASA Technical Reports Server (NTRS)

    Metcalf, Kenneth J.

    2011-01-01

    Power management and distribution (PMAD) models were developed in the early 1990's to model candidate architectures for various Space Exploration Initiative (SEI) missions. They were used to generate "ballpark" component mass estimates to support conceptual PMAD system design studies. The initial set of models was provided to NASA Lewis Research Center (since renamed Glenn Research Center) in 1992. They were developed to estimate the characteristics of power conditioning components predicted to be available in the 2005 timeframe. Early 90's component and device designs and material technologies were projected forward to the 2005 timeframe, and algorithms reflecting those design and material improvements were incorporated into the models to generate mass, volume, and efficiency estimates for circa 2005 components. The models are about ten years old now and NASA GRC requested a review of them to determine if they should be updated to bring them into agreement with current performance projections or to incorporate unforeseen design or technology advances. This report documents the results of this review and the updated power conditioning models and new transmission line models generated to estimate post 2005 PMAD system masses and sizes. This effort continues the expansion and enhancement of a library of PMAD models developed to allow system designers to assess future power system architectures and distribution techniques quickly and consistently.

  15. Design of Instantaneous High Power Supply System with power distribution management for portable military devices

    NASA Astrophysics Data System (ADS)

    Kwak, Kiho; Kwak, Dongmin; Yoon, Joohong

    2015-08-01

    A design of an Instantaneous High Power Supply System (IHPSS) with a power distribution management (PDM) for portable military devices is newly addressed. The system includes a power board and a hybrid battery that can not only supply instantaneous high power but also maintain stable operation at critical low temperature (-30 °C). The power leakage and battery overcharge are effectively prevented by the optimal PDM. The performance of the proposed system under the required pulse loads and the operating conditions of a Korean Advanced Combat Rifle employed in the battlefield is modeled with simulations and verified experimentally. The system with the IHPSS charged the fuse setter with 1.7 times higher voltage (8.6 V) than the one without (5.4 V) under the pulse discharging rate (1 A at 0.5 duty, 1 ms) for 500 ms.

  16. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    SciTech Connect

    Perkins, R. J.; Ahn, Joonwook; Bell, R. E.; Bertelli, Nicola; Diallo, A.; Gerhardt, S.; Gray, T. K.; Green, David L; Jaeger, E. F.; Hosea, J.; Jaworski, M. A.; LeBlanc, B; Kramer, G.; McLean, Adam G; Maingi, Rajesh; Phillips, C. K.; Podesta, M.; Ryan, Philip Michael; Sabbagh, S. A.; Scotti, F.; Taylor, G.; Wilson, J. R.

    2013-01-01

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  17. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    SciTech Connect

    Perkins, R. J.; Bell, R. E.; Bertelli, N.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; LeBlanc, B. P.; Kramer, G. J.; Maingi, R.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Scotti, F.; Taylor, G.; Wilson, J. R.; Ahn, J-W.; Gray, T. K.; Green, D. L.; McLean, A.; and others

    2014-02-12

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  18. Using reanalysis data for the prediction of seasonal wind turbine power losses due to icing

    NASA Astrophysics Data System (ADS)

    Burtch, Daniel G.

    The Northern Plains region of the United States is home to a significant amount of potential wind energy. However, in winter months capturing this potential power is severely impacted by the meteorological conditions, in the form of icing. Predicting the expected loss in power production due to icing is a valuable parameter that can be used in wind turbine operations, determination of wind turbine site locations and long-term energy estimates which are used for financing purposes. Currently, losses due to icing must be estimated when developing predictions for turbine feasibility and financing studies, while icing maps, a tool commonly used in Europe, are lacking in the United States. This study uses the Modern-Era Retrospective Analysis for Research and Applications (MERRA) dataset in conjunction with turbine production data and in-situ wind measurements to investigate six methods of predicting seasonal losses (October-March) due to icing at two sites located in Petersburg, ND and Valley City, ND. The prediction of icing losses is based on temperature and relative humidity thresholds and is accomplished using six methods. Three methods use a Measure-Correlate-Predict (MCP) and flow model (WAsP) analysis for the determination of wind speeds and MERRA for temperature and relative humidity, while three methods use MERRA for all three variables. For each season from 2002 to 2010, the predicted losses due to icing are determined for a range of relative humidity thresholds and compared with observed icing losses. An optimal relative humidity is then determined and tested on all seasons from 2002 to 2013. The prediction methods are then compared to a common practice used in the wind energy industry of assuming a constant percentage loss for icing over the same time period. The three methods using MERRA data alone show severe deficiencies in the accurate determination of wind speeds which leads to a large underprediction in accurate power output. Of the three MCP

  19. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    PubMed Central

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC. PMID:26792556

  20. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    NASA Astrophysics Data System (ADS)

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.

  1. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    David Deangelis; Rich Depuy; Debashis Dey; Georgia Karvountzi; Nguyen Minh; Max Peter; Faress Rahman; Pavel Sokolov; Deliang Yang

    2004-09-30

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the April to October 2004 reporting period in Task 2.3 (SOFC Scaleup for Hybrid and Fuel Cell Systems) under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL), entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. This study analyzes the performance and economics of power generation systems for central power generation application based on Solid Oxide Fuel Cell (SOFC) technology and fueled by natural gas. The main objective of this task is to develop credible scale up strategies for large solid oxide fuel cell-gas turbine systems. System concepts that integrate a SOFC with a gas turbine were developed and analyzed for plant sizes in excess of 20 MW. A 25 MW plant configuration was selected with projected system efficiency of over 65% and a factory cost of under $400/kW. The plant design is modular and can be scaled to both higher and lower plant power ratings. Technology gaps and required engineering development efforts were identified and evaluated.

  2. Enhanced power quality based single phase photovoltaic distributed generation system

    NASA Astrophysics Data System (ADS)

    Panda, Aurobinda; Pathak, M. K.; Srivastava, S. P.

    2016-08-01

    This article presents a novel control strategy for a 1-ϕ 2-level grid-tie photovoltaic (PV) inverter to enhance the power quality (PQ) of a PV distributed generation (PVDG) system. The objective is to obtain the maximum benefits from the grid-tie PV inverter by introducing current harmonics as well as reactive power compensation schemes in its control strategy, thereby controlling the PV inverter to achieve multiple functions in the PVDG system such as: (1) active power flow control between the PV inverter and the grid, (2) reactive power compensation, and (3) grid current harmonics compensation. A PQ enhancement controller (PQEC) has been designed to achieve the aforementioned objectives. The issue of underutilisation of the PV inverter in nighttime has also been addressed in this article and for the optimal use of the system; the PV inverter is used as a shunt active power filter in nighttime. A prototype model of the proposed system is developed in the laboratory, to validate the effectiveness of the control scheme, and is tested with the help of the dSPACE DS1104 platform.

  3. Full-Scale Prestress Loss Monitoring of Damaged RC Structures Using Distributed Optical Fiber Sensing Technology

    PubMed Central

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams. PMID:22778590

  4. Full-scale prestress loss monitoring of damaged RC structures using distributed optical fiber sensing technology.

    PubMed

    Lan, Chunguang; Zhou, Zhi; Ou, Jinping

    2012-01-01

    For the safety of prestressed structures, prestress loss is a critical issue that will increase with structural damage, so it is necessary to investigate prestress loss of prestressed structures under different damage scenarios. Unfortunately, to date, no qualified techniques are available due to difficulty for sensors to survive in harsh construction environments of long service life and large span. In this paper, a novel smart steel strand based on the Brillouin optical time domain analysis (BOTDA) sensing technique was designed and manufactured, and then series of tests were used to characterize properties of the smart steel strands. Based on prestress loss principle analysis of damaged structures, laboratory tests of two similar beams with different damages were used to verify the concept of full-scale prestress loss monitoring of damaged reinforced concrete (RC) beams by using the smart steel strands. The prestress losses obtained from the Brillouin sensors are compared with that from conventional sensors, which provided the evolution law of prestress losses of damaged RC beams. The monitoring results from the proposed smart strand can reveal both spatial distribution and time history of prestress losses of damaged RC beams.

  5. Design of Distributed Controllers Seeking Optimal Power Flow Solutions Under Communication Constraints

    SciTech Connect

    Dall'Anese, Emiliano; Simonetto, Andrea; Dhople, Sairaj

    2016-12-29

    This paper focuses on power distribution networks featuring inverter-interfaced distributed energy resources (DERs), and develops feedback controllers that drive the DER output powers to solutions of time-varying AC optimal power flow (OPF) problems. Control synthesis is grounded on primal-dual-type methods for regularized Lagrangian functions, as well as linear approximations of the AC power-flow equations. Convergence and OPF-solution-tracking capabilities are established while acknowledging: i) communication-packet losses, and ii) partial updates of control signals. The latter case is particularly relevant since it enables asynchronous operation of the controllers where DER setpoints are updated at a fast time scale based on local voltage measurements, and information on the network state is utilized if and when available, based on communication constraints. As an application, the paper considers distribution systems with high photovoltaic integration, and demonstrates that the proposed framework provides fast voltage-regulation capabilities, while enabling the near real-time pursuit of solutions of AC OPF problems.

  6. Design of Distributed Controllers Seeking Optimal Power Flow Solutions under Communication Constraints: Preprint

    SciTech Connect

    Dall'Anese, Emiliano; Simonetto, Andrea; Dhople, Sairaj

    2016-12-01

    This paper focuses on power distribution networks featuring inverter-interfaced distributed energy resources (DERs), and develops feedback controllers that drive the DER output powers to solutions of time-varying AC optimal power flow (OPF) problems. Control synthesis is grounded on primal-dual-type methods for regularized Lagrangian functions, as well as linear approximations of the AC power-flow equations. Convergence and OPF-solution-tracking capabilities are established while acknowledging: i) communication-packet losses, and ii) partial updates of control signals. The latter case is particularly relevant since it enables asynchronous operation of the controllers where DER setpoints are updated at a fast time scale based on local voltage measurements, and information on the network state is utilized if and when available, based on communication constraints. As an application, the paper considers distribution systems with high photovoltaic integration, and demonstrates that the proposed framework provides fast voltage-regulation capabilities, while enabling the near real-time pursuit of solutions of AC OPF problems.

  7. ELECTRON CYCLOTRON MASER INSTABILITY IN SPACE PLASMAS WITH KAPPA LOSS-CONE DISTRIBUTION

    SciTech Connect

    Tang, J. F.; Wu, D. J.; Yan, Y. H.

    2012-02-01

    It is well known that non-thermal electrons, often modeled by the kappa distribution, are ubiquitously observed in space. Kappa-type distributions have been widely discussed in various plasma environments. On the other hand, when these non-thermal electrons are trapped by magnetic fields in space they frequently have a loss-cone distribution in velocity space. In this paper, we investigated the growth rates of electron cyclotron maser (ECM) instability in space plasmas by using a kappa loss-cone distribution. Based on the cold plasma assumption and weakly relativistic approximation, the results show that non-thermal electrons with such a distribution can excite ECM emission efficiently. The growth rates of O1 and X2 modes both increase with the kappa spectral index ({kappa}) but the growth rate of X2 mode increases slightly more rapidly than that of O1 mode. The present analysis also shows that the growth rates increase rapidly with the loss-cone index {sigma} for {sigma} < 10 but increase comparatively slowly for larger {sigma} values.

  8. Effect of Distributed Photovoltaic Generation on the Voltage Magnitude in a Self-Contained Power Supply System

    NASA Astrophysics Data System (ADS)

    Lukutin, B. V.; Shandarova, E. B.; Makarova, A. F.; Shvartsman, I. B.

    2016-04-01

    A promising way to increase the technical and economic characteristics of standalone power supply systems is to incorporate renewable energy installations in their structure. This saves fuel and extends the operational life of diesel power stations. The most common option is a hybrid system with photovoltaic power stations incorporated into the local network of the diesel power station. This paper deals with the dependence of the deflection voltage and power losses in the electric power transmission line on the graphs of electrical loads, the parameters of elements of the power supply system, connection points and the capacity of distributed photovoltaic power stations. Research has been carried out on the common low-voltage power supply systems of the radial type (0.4 kV) with an installed capacity of up to 100 kW. The studies have been conducted by simulating the operating modes of hybrid power systems of various configurations. As a result of these studies recommendations to reduce losses and voltage variations in the network by selecting the power and photovoltaic power connection points have been put forward.

  9. Economic optimization of the energy transport component of a large distributed solar power plant

    NASA Technical Reports Server (NTRS)

    Turner, R. H.

    1976-01-01

    A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.

  10. Analysis of Loss-of-Offsite-Power Events 1998–2013

    SciTech Connect

    Schroeder, John Alton

    2015-02-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. Risk analyses suggest that loss of all alternating current power contributes over 70% of the overall risk at some U.S. nuclear plants. LOOP event and subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1997 through 2013. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. The emergency diesel generator failure modes considered are failure to start, failure to load and run, and failure to run more than 1 hour. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant trends in LOOP frequencies over the 1997–2013 period are identified. There is a possibility that a significant trend in grid-related LOOP frequency exists that is not easily detected by a simple analysis. Statistically significant increases in recovery times after grid- and switchyard-related LOOPs are identified.

  11. Analysis of Loss-of-Offsite-Power Events 1998–2012

    SciTech Connect

    T. E. Wierman

    2013-10-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. Risk analyses performed loss of all alternating current power contributes over 70% of the overall risk at some U.S. nuclear plants. LOOP event and subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience from fiscal year 1998 through 2012. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. The EDG failure modes considered are failure to start, failure to load and run, and failure to run more than 1 hour. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. A statistically significant increase in industry performance was identified for plant-centered and switchyard-centered LOOP frequencies. There is no statistically significant trend in LOOP durations.

  12. Catchment power and the joint distribution of elevation and travel distance to the outlet

    NASA Astrophysics Data System (ADS)

    Sklar, Leonard S.; Riebe, Clifford S.; Lukens, Claire E.; Bellugi, Dino

    2016-10-01

    The delivery of water, sediment, and solutes by catchments is influenced by the distribution of source elevations and their travel distances to the outlet. For example, elevation affects the magnitude and phase of precipitation, as well as the climatic factors that govern rock weathering, which influence the production rate and initial particle size of sediments. Travel distance, in turn, affects the timing of flood peaks at the outlet and the degree of sediment size reduction by wear, which affects particle size distributions at the outlet. The distributions of elevation and travel distance have been studied extensively but separately, as the hypsometric curve and width function. Yet a catchment can be considered as a collection of points, each with paired values of elevation and travel distance. For every point, the ratio of elevation to travel distance defines the mean slope for transport of mass to the outlet. Recognizing that mean slope is proportional to the average rate of loss of potential energy by water and sediment during transport to the outlet, we use the joint distribution of elevation and travel distance to define two new metrics for catchment geometry: "source-area power", and the corresponding catchment-wide integral "catchment power". We explore patterns in source-area and catchment power across three study catchments spanning a range of relief and drainage area. We then develop an empirical algorithm for generating synthetic source-area power distributions, which can be parameterized with data from natural catchments. This new way of quantifying the three-dimensional geometry of catchments can be used to explore the effects of topography on the distribution on fluxes of water, sediment, isotopes, and other landscape products passing through catchment outlets, and may provide a fresh perspective on problems of both practical and theoretical interest.

  13. Experimental study on guide friction contribution in global power loss of a tooth chain transmission

    NASA Astrophysics Data System (ADS)

    Velicu, R.; Papuc, R.; Gavrila, C. C.; Popa, S.

    2017-02-01

    The subject of the paper is the friction between a tooth chain and the guide. An experimental study is developed with the aim of determining the contribution of chain-guide friction on the global friction of a basic tooth chain transmission. The measurements have been made on a chain friction rig, testing a basic tooth chain transmission with transmission ratio equal to 1, with a controlled tensioning device. The following parameters can be adjusted and measured: rotational speed, tensioning force in the chain, position of the guide, temperature and pressure of the oil used for lubrication. Friction torque at the input shaft is a sum of friction torques coming from bearings, chain and guide. The paper presents the contribution of the guide in the power loss by friction, as percent of the power loss from friction in chain and guide together. Influences of speed, tensioning force and oil temperature are presented.

  14. Polarizing Field and Particle Concentration Dependence of the Magnetic Loss Power in Ferrofluids

    NASA Astrophysics Data System (ADS)

    Fannin, Paul C.; Malaescu, Iosif; Stefu, Nicoleta; Marin, Catalin N.

    2009-05-01

    The frequency (f) and polarizing field (H) dependence of the complex magnetic permeability μ(f,H) = μ'(f,H)-iμ″(f,H), of different magnetic fluid samples, over the range 100 MHz to 6 GHz and 0 to 102.4 kA/m, respectively, were analyzed. Starting from an initial magnetic fluid sample (sample A) with magnetite particles dispersed in kerosene and stabilized with oleic acid, having particle concentration n = 19.16ṡ1022 m-3, three samples were obtained by successive dilution with kerosene (with a dilution ratio 2:3) (samples A1, A2, and A3). Based on the complex magnetic permeability measurements of each sample, and for each field value, values of the specific magnetic loss power were obtained. We have also studied the dependence on particle concentration of the magnetic loss power, both in zero polarizing field and in the presence of the polarizing field.

  15. AC losses in superconductors with a power-law constitutive relation

    NASA Astrophysics Data System (ADS)

    Agassi, Y. D.

    2015-10-01

    The observed constitutive relation between the electrical field and current density in cuprates high temperature superconductors is a power-law of the current. This functional dependence is presumably related to the giant flux-creep domain. It is shown that this constitutive relation reflects the statistical spread of the pinning potential associated with creep motion of vortex bundles. The AC losses emanating from a power-law constitutive relation are calculated in an approach focused on the superconductor's electric field. For a slab geometry in the presence of a parallel AC magnetic field or transport current, the calculated AC-loss scaling laws are consistent with BSCCO data and the critical state model. Extensions of the approach are briefly discussed.

  16. Compact, low-loss and low-power 8×8 broadband silicon optical switch.

    PubMed

    Chen, Long; Chen, Young-kai

    2012-08-13

    We demonstrated a 8×8 broadband optical switch on silicon for transverse-electrical polarization using a switch-and-selector architecture. The switch has a footprint of only 8 mm × 8 mm, minimum on-chip loss of about 4 dB, and a port-to-port insertion loss variation of only 0.8 dB near some spectral regions. The port-to-port isolation is above 30 dB over the entire 80-nm-wide spectral range or above 45 dB near the central 30 nm. We also demonstrated a switching power of less than 1.5 mW per element and a speed of 2 kHz, and estimated the upper bound of total power consumption to be less than 70 mW even without optimization of the default state of the individual switch elements.

  17. Assessment of technologies for predicting insertion loss and directivity of power plant exhaust systems

    NASA Astrophysics Data System (ADS)

    Cummins, Jim R.; Loewenstein, Marshall

    2005-09-01

    Much technology exists for predicting the insertion loss, directivity and radiation of various components in a power plant. For example, the ASHRAE noise guide gives the IL and/or directivity for many duct configurations. Unfortunately, there are also many components or geometries for which there is currently no practical prediction methodology. The state of the technology for predicting insertion loss, directivity and sound radiation by power plant components, especially ducted sources, such as intake and exhaust, is reviewed with emphasis on modeling techniques and verification. Several cases where the normal prediction methods are both adequate and inadequate are presented. Suggestions are given as to methods and/or future development that could provide more accurate, reliable, or useable results.

  18. Solar power generation by use of Stirling engine and heat loss analysis of its cavity receiver

    NASA Astrophysics Data System (ADS)

    Hussain, Tassawar

    Since concentrated power generation by Stirling engine has the highest efficiency therefore efficient power generation by concentrated systems using a Stirling engine was a primary motive of this research. A 1 kW Stirling engine was used to generate solar power using a Fresnel lens as a concentrator. Before operating On-Sun test, engine's performance test was conducted by combustion test. Propane gas with air was used to provide input heat to the Stirling Engine and 350W power was generated with 14% efficiency of the engine. Two kinds of receivers were used for On-Sun test, first type was the Inconel tubes with trapped helium gas and the second one was the heat pipe. Heat pipe with sodium as a working fluid is considered the best approach to transfer the uniform heat from the receiver to the helium gas in the heater head of the engine. A Number of On-Sun experiments were performed to generate the power. A minimum 1kW input power was required to generate power from the Stirling engine but it was concluded that the available Fresnel lens was not enough to provide sufficient input to the Stirling engine and hence engine was lagged to generate the solar power. Later on, for a high energy input a Beam Down system was also used to concentrate the solar light on the heater head of the Stirling engine. Beam down solar system in Masdar City UAE, constructed in 2009 is a variation of central receiver plant with cassegrainian optics. Around 1.5kW heat input was achieved from the Beam Down System and it was predicted that the engine receiver at beam down has the significant heat losses of about 900W. These high heat losses were the major hurdles to get the operating temperature (973K) of the heat pipes; hence power could not be generated even during the Beam Down test. Experiments were also performed to find the most suitable Cavity Receiver configuration for maximum solar radiation utilizations by engine receiver. Dimensionless parameter aperture ration (AR=d/D) and aperture

  19. Life cycle assessment of overhead and underground primary power distribution.

    PubMed

    Bumby, Sarah; Druzhinina, Ekaterina; Feraldi, Rebe; Werthmann, Danae; Geyer, Roland; Sahl, Jack

    2010-07-15

    Electrical power can be distributed in overhead or underground systems, both of which generate a variety of environmental impacts at all stages of their life cycles. While there is considerable literature discussing the trade-offs between both systems in terms of aesthetics, safety, cost, and reliability, environmental assessments are relatively rare and limited to power cable production and end-of-life management. This paper assesses environmental impacts from overhead and underground medium voltage power distribution systems as they are currently built and managed by Southern California Edison (SCE). It uses process-based life cycle assessment (LCA) according to ISO 14044 (2006) and SCE-specific primary data to the extent possible. Potential environmental impacts have been calculated using a wide range of midpoint indicators, and robustness of the results has been investigated through sensitivity analysis of the most uncertain and potentially significant parameters. The studied underground system has higher environmental impacts in all indicators and for all parameter values, mostly due to its higher material intensity. For both systems and all indicators the majority of impact occurs during cable production. Promising strategies for impact reduction are thus cable failure rate reduction for overhead and cable lifetime extension for underground systems.

  20. Estimating spatial distribution of soil loss over Seyhan River Basin in Turkey

    NASA Astrophysics Data System (ADS)

    İrvem, Ahmet; Topaloğlu, Fatih; Uygur, Veli

    2007-03-01

    SummaryThe purpose of this study was to investigate the spatial distribution of annual soil loss in Seyhan River Basin using USLE model. A geographic information system (GIS) was used to generate maps of the USLE factors which are rainfall erosivity ( R), soil erodibility ( K), slope length and steepness ( LS), cover ( C) and conservation practices ( P) factors. By integrating these maps in GIS, spatial distribution of soil loss over the Seyhan River Basin was obtained. Annual average soil loss for the Seyhan River Basin was 16.38 t ha -1 y -1. Annual soil loss more than 200 t ha -1 y -1 in pixel level was in the southern region, while the northern region showed the lower annual values. These results are verified by comparing sediment yield measurements in the basin. An area about 198.25 km 2 (0.96%) experiences extremely severe erosion risk, which needs suitable conservation measures to be adopted on a priority basis. The spatial distribution of erosion risk classes estimated 61.03% very low, 8.76% low, 23.52% moderate, 4.03% severe and 1.70% very severe. Thus, the USLE model was used in a GIS environment to identify regions susceptible to water erosion and needing immediate soil conservation planning and application in the Seyhan River Basin in Turkey.

  1. Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

    SciTech Connect

    Jeong, S. C.; Oyaizu, M.; Imai, N.; Hirayama, Y.; Ishiyama, H.; Miyatake, H.; Niki, K.; Okada, M.; Watanabe, Y. X.; Otokawa, Y.; Osa, A.; Ichikawa, S.

    2011-03-15

    The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

  2. Time series power flow analysis for distribution connected PV generation.

    SciTech Connect

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  3. Power system voltage stability and agent based distribution automation in smart grid

    NASA Astrophysics Data System (ADS)

    Nguyen, Cuong Phuc

    2011-12-01

    negotiation. Communication latency is modeled using a user-defined probability density function. Failure-tolerant communication strategies are developed for agent communications. Major elements of advanced DA are developed in a completely distributed way and successfully tested for several IEEE standard systems, including: Fault Detection, Location, Isolation, and Service Restoration (FLISR); Coordination of Distributed Energy Storage Systems (DES); Distributed Power Flow (DPF); Volt-VAR Control (VVC); and Loss Reduction (LR).

  4. A Multi-Agent Design for Power Distribution Systems Automation

    NASA Astrophysics Data System (ADS)

    Ghorbani, M. Jawad

    A new Multi Agent System (MAS) design for fault location, isolation and restoration in power distribution systems is presented. In proposed approach, when there is a fault in the Power Distribution System (PDS), MAS quickly isolates the fault and restores the service to fault-free zones. Hierarchical coordination strategy is introduced to manage the agents which integrate the advantages of both centralized and decentralized coordination strategies. In this framework, Zone Agent (ZA) locate and isolate the fault based on the locally available information and assist the Feeder Agent (FA) for reconfiguration and restoration. FA can solve the restoration problem using the existing algorithms for the 0-1 Knapsack problem. A novel Q-learning mechanism is also introduced to support the FAs in decision making for restoration. Also a distributed MAS-Based Load Shedding (LS) technique has been used to supply as many of higher priority customers as possible, in case there is more demand than generation. The design is illustrated by the use of simulation case studies for fault location, isolation and restoration on West Virginia Super Circuit (WVSC) and hardware implementation for fault location and isolation in a laboratory platform. The results from the case studies indicate the performance of proposed MAS designs.

  5. Power-law distributions from additive preferential redistributions

    NASA Astrophysics Data System (ADS)

    Ree, Suhan

    2006-02-01

    We introduce a nongrowth model that generates the power-law distribution with the Zipf exponent. There are N elements, each of which is characterized by a quantity, and at each time step these quantities are redistributed through binary random interactions with a simple additive preferential rule, while the sum of quantities is conserved. The situation described by this model is similar to those of closed N -particle systems when conservative two-body collisions are only allowed. We obtain stationary distributions of these quantities both analytically and numerically while varying parameters of the model, and find that the model exhibits the scaling behavior for some parameter ranges. Unlike well-known growth models, this alternative mechanism generates the power-law distribution when the growth is not expected and the dynamics of the system is based on interactions between elements. This model can be applied to some examples such as personal wealths, city sizes, and the generation of scale-free networks when only rewiring is allowed.

  6. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    DOE PAGES

    Dailey, James; Agarwal, Anjali; Toliver, Paul; ...

    2015-11-12

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA.

  7. Loss resilience for two-qubit state transmission using distributed phase sensitive amplification

    PubMed Central

    Dailey, James M.; Agarwal, Anjali; Toliver, Paul; Peters, Nicholas A.

    2015-01-01

    We transmit phase-encoded non-orthogonal quantum states through a 5-km long fibre-based distributed optical phase-sensitive amplifier (OPSA) using telecom-wavelength photonic qubit pairs. The gain is set to equal the transmission loss to probabilistically preserve input states during transmission. While neither state is optimally aligned to the OPSA, each input state is equally amplified with no measurable degradation in state quality. These results promise a new approach to reduce the effects of loss by encoding quantum information in a two-qubit Hilbert space which is designed to benefit from transmission through an OPSA. PMID:26559465

  8. Thermal Diagnosis of Rural Power Grid Distribution Substation Electrical Joints

    NASA Astrophysics Data System (ADS)

    Ge, Le-Yi; Wang, Yue-Xin; Qiao, Yu-Jing

    2016-05-01

    Rural Power Grid Distribution Substation (RPGDS) in long-term operation process, often due to thermal power of the high voltage unit is very big, which leads to serious local heat. In order to ensure the stability, security and reliability, it is necessary to measure and detect for some specific electrical joints of RPGDS. This paper presents a novel diagnosis method based on infrared thermal imaging technology for the specific electrical joints, the method obtains the original infrared thermal image firstly, then carries out following steps as: preprocessing, noise filtering, image enhancement, and extract image edge line, finally, analyzes the results of infrared thermal image data processing. This novel method not only overcomes the shortcomings of traditional contact measurement methods, but can realize fault diagnose more accurately for the electrical joints.

  9. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh

    2004-07-04

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the January to June 2004 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  10. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Faress Rahman; Nguyen Minh

    2004-01-04

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the July 2003 to December 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  11. Tomographic determination of the power distribution in electron beams

    DOEpatents

    Teruya, Alan T.; Elmer, John W.

    1996-01-01

    A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process.

  12. Operational maintenance data for power generation distribution and HVAC components

    SciTech Connect

    Hollis, H.D.; Hale, P.S. Jr.; Arno, R.G.; Briggs, S.J.

    1995-12-31

    This paper describes the culmination of a 24,000 man hour effort to collect operational and maintenance data on 239 power generation, power distribution and HVAC items, including gas turbine generators, diesel engine generators, switch gear assemblies, cables, boilers, piping, valves and chillers. This program was designed to determine the effects of new technology equipment, i.e., equipment installed after 1971, on availability. The central hypothesis was that this new equipment would exhibit a significant increase in availability, with corresponding decreases in required maintenance and the occurrence of failures. Information was obtained on a variety of commercial and industrial facility types (including office buildings, hospitals, water treatment facilities, prisons, utilities, manufacturing facilities, school universities and bank computer centers), with varying degrees of maintenance quality.

  13. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh; Faress Rahman

    2002-12-31

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC during the October 2002 to December 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The following activities have been carried out during this reporting period: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} Part-load performance analysis was conducted {lg_bullet} Primary system concept was down-selected {lg_bullet} Dynamic control model has been developed {lg_bullet} Preliminary heat exchanger designs were prepared {lg_bullet} Pressurized SOFC endurance testing was performed

  14. Probability distributions and confidence intervals for simulated power law noise.

    PubMed

    Ashby, Neil

    2015-01-01

    A method for simulating power law noise in clocks and oscillators is presented based on modification of the spectrum of white phase noise, then Fourier transforming to the time domain. Symmetric real matrices are introduced whose traces-the sums of their eigenvalues-are equal to the Allan variances, in overlapping or non-overlapping forms, as well as for the corresponding forms of the modified Allan variance. We show that the standard expressions for spectral densities, and their relations to Allan variance, are obtained with this method. The matrix eigenvalues determine probability distributions for observing a variance at an arbitrary value of the sampling interval τ, and hence for estimating confidence in the measurements. Examples are presented for the common power-law noises. Extension to other variances such as the Hadamard variance, and variances with dead time, are discussed.

  15. Tomographic determination of the power distribution in electron beams

    DOEpatents

    Teruya, A.T.; Elmer, J.W.

    1996-12-10

    A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams is disclosed. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process. 4 figs.

  16. A distributed control approach for power and energy management in a notional shipboard power system

    NASA Astrophysics Data System (ADS)

    Shen, Qunying

    The main goal of this thesis is to present a power control module (PCON) based approach for power and energy management and to examine its control capability in shipboard power system (SPS). The proposed control scheme is implemented in a notional medium voltage direct current (MVDC) integrated power system (IPS) for electric ship. To realize the control functions such as ship mode selection, generator launch schedule, blackout monitoring, and fault ride-through, a PCON based distributed power and energy management system (PEMS) is developed. The control scheme is proposed as two-layer hierarchical architecture with system level on the top as the supervisory control and zonal level on the bottom as the decentralized control, which is based on the zonal distribution characteristic of the notional MVDC IPS that was proposed as one of the approaches for Next Generation Integrated Power System (NGIPS) by Norbert Doerry. Several types of modules with different functionalities are used to derive the control scheme in detail for the notional MVDC IPS. Those modules include the power generation module (PGM) that controls the function of generators, the power conversion module (PCM) that controls the functions of DC/DC or DC/AC converters, etc. Among them, the power control module (PCON) plays a critical role in the PEMS. It is the core of the control process. PCONs in the PEMS interact with all the other modules, such as power propulsion module (PPM), energy storage module (ESM), load shedding module (LSHED), and human machine interface (HMI) to realize the control algorithm in PEMS. The proposed control scheme is implemented in real time using the real time digital simulator (RTDS) to verify its validity. To achieve this, a system level energy storage module (SESM) and a zonal level energy storage module (ZESM) are developed in RTDS to cooperate with PCONs to realize the control functionalities. In addition, a load shedding module which takes into account the reliability

  17. EMC and power quality standards for 20-kHz power distribution

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1987-01-01

    The Space Station Power Distribution System has been baselined as a sinusoidal single phase, 440 VRMS system. This system has certain unique characteristics directly affecting its application. In particular, existing systematic description and control documents were modified to reflect the high operating frequency. This paper will discuss amendments made on Mil STD 704 (Electrical Power Characteristics), and Mil STD 461-B (Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference). In some cases these amendments reflect changes of several orders of magnitude. Implications and impacts of these changes are discussed.

  18. Single-phase power distribution system power flow and fault analysis

    NASA Technical Reports Server (NTRS)

    Halpin, S. M.; Grigsby, L. L.

    1992-01-01

    Alternative methods for power flow and fault analysis of single-phase distribution systems are presented. The algorithms for both power flow and fault analysis utilize a generalized approach to network modeling. The generalized admittance matrix, formed using elements of linear graph theory, is an accurate network model for all possible single-phase network configurations. Unlike the standard nodal admittance matrix formulation algorithms, the generalized approach uses generalized component models for the transmission line and transformer. The standard assumption of a common node voltage reference point is not required to construct the generalized admittance matrix. Therefore, truly accurate simulation results can be obtained for networks that cannot be modeled using traditional techniques.

  19. Automated fault location and diagnosis on electric power distribution feeders

    SciTech Connect

    Zhu, J.; Lubkeman, D.L.; Girgis, A.A.

    1997-04-01

    This paper presents new techniques for locating and diagnosing faults on electric power distribution feeders. The proposed fault location and diagnosis scheme is capable of accurately identifying the location of a fault upon its occurrence, based on the integration of information available from disturbance recording devices with knowledge contained in a distribution feeder database. The developed fault location and diagnosis system can also be applied to the investigation of temporary faults that may not result in a blown fuse. The proposed fault location algorithm is based on the steady-state analysis of the faulted distribution network. To deal with the uncertainties inherent in the system modeling and the phasor estimation, the fault location algorithm has been adapted to estimate fault regions based on probabilistic modeling and analysis. Since the distribution feeder is a radial network, multiple possibilities of fault locations could be computed with measurements available only at the substation. To identify the actual fault location, a fault diagnosis algorithm has been developed to prune down and rank the possible fault locations by integrating the available pieces of evidence. Testing of the developed fault location and diagnosis system using field data has demonstrated its potential for practical use.

  20. Induced magnetization and power loss for a periodically driven system of ferromagnetic nanoparticles with randomly oriented easy axes

    NASA Astrophysics Data System (ADS)

    Denisov, S. I.; Lyutyy, T. V.; Pedchenko, B. O.; Hryshko, O. M.

    2016-07-01

    We study the effect of an elliptically polarized magnetic field on a system of noninteracting, single-domain ferromagnetic nanoparticles characterized by a uniform distribution of easy axis directions. Our main goal is to determine the average magnetization of this system and the power loss in it. In order to calculate these quantities analytically, we develop a general perturbation theory for the Landau-Lifshitz-Gilbert (LLG) equation and find its steady-state solution for small magnetic field amplitudes. On this basis, we derive the second-order expressions for the average magnetization and power loss, investigate their dependence on the magnetic field frequency, and analyze the role of subharmonic resonances resulting from the nonlinear nature of the LLG equation. For arbitrary amplitudes, the frequency dependence of these quantities is obtained from the numerical solution of this equation. The impact of transitions between different regimes of regular and chaotic dynamics of magnetization, which can be induced in nanoparticles by changing the magnetic field frequency, is examined in detail.

  1. Improved designs for p-i-n OLEDs towards the minimal power loss of devices

    NASA Astrophysics Data System (ADS)

    Qin, Dashan

    2014-05-01

    Currently, the low yield, high power loss, and poor stability of organic light emitting diodes (OLEDs) panels are remaining as the obstacles to the fast growth of the OLED industry, especially for the lighting application. The p-i-n OLEDs have been widely recognized as the promising method to circumvent these bottleneck factors, due to the unique merit of the electrical doping to enable low power loss. In p-i-n OLEDs, the frequently used n-doped electron transport layers (n-ETL1) such as n-BCP, n-Alq3 possess markedly lower conductivities but better capabilities of injecting electrons into ETL such as BCP, Alq3, as compared to another class of n-doped ETLs (n-ETL2), e.g., n-NTCDA, n-PTCDA, n-C60. Thus, in order to minimize the electron loss, we provide the structure of uniting two n-doped layers, cathode/ n-ETL2/ n-ETL1/ ETL. In p-i-n OLEDs, the hole current injected from the single p-doped hole transport layer (p-HTL) into the neat HTL must be limited, because the higher conductivity p-HTL has the higher lying highest occupied molecular orbital (HOMO) level, leading to a larger hole transport energy barrier (φB) at the interface with the neat HTL. Therefore, in order to minimize the hole loss, we suggest the structure of uniting two p-HTLs, anode/ p-HTL2/ p-HTL1/ HTL. The p-HTL2 possesses high-lying HOMO level and thereby high conductivity, decreasing the ohmic loss in the hole conduction; the p-HTL1 features a low-lying HOMO level, reducing the φB.

  2. Winter respiratory C losses provide explanatory power for net ecosystem productivity

    NASA Astrophysics Data System (ADS)

    Haeni, M.; Zweifel, R.; Eugster, W.; Gessler, A.; Zielis, S.; Bernhofer, C.; Carrara, A.; Grünwald, T.; Havránková, K.; Heinesch, B.; Herbst, M.; Ibrom, A.; Knohl, A.; Lagergren, F.; Law, B. E.; Marek, M.; Matteucci, G.; McCaughey, J. H.; Minerbi, S.; Montagnani, L.; Moors, E.; Olejnik, J.; Pavelka, M.; Pilegaard, K.; Pita, G.; Rodrigues, A.; Sanz Sánchez, M. J.; Schelhaas, M.-J.; Urbaniak, M.; Valentini, R.; Varlagin, A.; Vesala, T.; Vincke, C.; Wu, J.; Buchmann, N.

    2017-01-01

    Accurate predictions of net ecosystem productivity (NEPc) of forest ecosystems are essential for climate change decisions and requirements in the context of national forest growth and greenhouse gas inventories. However, drivers and underlying mechanisms determining NEPc (e.g., climate and nutrients) are not entirely understood yet, particularly when considering the influence of past periods. Here we explored the explanatory power of the compensation day (cDOY)—defined as the day of year when winter net carbon losses are compensated by spring assimilation—for NEPc in 26 forests in Europe, North America, and Australia, using different NEPc integration methods. We found cDOY to be a particularly powerful predictor for NEPc of temperate evergreen needleleaf forests (R2 = 0.58) and deciduous broadleaf forests (R2 = 0.68). In general, the latest cDOY correlated with the lowest NEPc. The explanatory power of cDOY depended on the integration method for NEPc, forest type, and whether the site had a distinct winter net respiratory carbon loss or not. The integration methods starting in autumn led to better predictions of NEPc from cDOY then the classical calendar method starting 1 January. Limited explanatory power of cDOY for NEPc was found for warmer sites with no distinct winter respiratory loss period. Our findings highlight the importance of the influence of winter processes and the delayed responses of previous seasons' climatic conditions on current year's NEPc. Such carry-over effects may contain information from climatic conditions, carbon storage levels, and hydraulic traits of several years back in time.

  3. An Efficacious Multi-Objective Fuzzy Linear Programming Approach for Optimal Power Flow Considering Distributed Generation

    PubMed Central

    Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri

    2016-01-01

    This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality. PMID:26954783

  4. An Efficacious Multi-Objective Fuzzy Linear Programming Approach for Optimal Power Flow Considering Distributed Generation.

    PubMed

    Warid, Warid; Hizam, Hashim; Mariun, Norman; Abdul-Wahab, Noor Izzri

    2016-01-01

    This paper proposes a new formulation for the multi-objective optimal power flow (MOOPF) problem for meshed power networks considering distributed generation. An efficacious multi-objective fuzzy linear programming optimization (MFLP) algorithm is proposed to solve the aforementioned problem with and without considering the distributed generation (DG) effect. A variant combination of objectives is considered for simultaneous optimization, including power loss, voltage stability, and shunt capacitors MVAR reserve. Fuzzy membership functions for these objectives are designed with extreme targets, whereas the inequality constraints are treated as hard constraints. The multi-objective fuzzy optimal power flow (OPF) formulation was converted into a crisp OPF in a successive linear programming (SLP) framework and solved using an efficient interior point method (IPM). To test the efficacy of the proposed approach, simulations are performed on the IEEE 30-busand IEEE 118-bus test systems. The MFLP optimization is solved for several optimization cases. The obtained results are compared with those presented in the literature. A unique solution with a high satisfaction for the assigned targets is gained. Results demonstrate the effectiveness of the proposed MFLP technique in terms of solution optimality and rapid convergence. Moreover, the results indicate that using the optimal DG location with the MFLP algorithm provides the solution with the highest quality.

  5. Energy loss distributions of relativistic protons axially channeled in a bent silicon crystal

    NASA Astrophysics Data System (ADS)

    Stojanov, Nace; Petrović, Srdjan; Nešković, Nebojša

    2013-05-01

    A detailed study of the energy loss distributions of the relativistic protons axially channeled in the bent < 100 > Si crystals is presented in this work. The bending angle was varied from 0 to 20 μrad, while the crystal thickness was equal to 1 mm. The proton energy was chosen to be 7 TeV in accordance with the Large Hadron Collider (LHC) project, at the European Organization for Nuclear Research (CERN), in Geneva, Switzerland. The energy loss distributions of the channeled protons were generated using the numerical solution of the proton equations of motion in the transverse plane and the computer simulation method. An accurate energy loss model was used, which takes into account the trajectory dependence of the energy loss of protons during their motion through the crystal channels. Further, the dispersion of the proton's scattering angle caused by its collisions with the electrons of the crystal and the divergence of the proton beam were taken into account. The calculated dependence of the number of dechanneled protons on the bending angle was excellently fitted by the Gompertz type dechanneling function.

  6. Evaluation of Potential Energy Loss Reduction and Savings for U. S. Army Electrical Distribution Systems

    DTIC Science & Technology

    1993-09-01

    CtC 14z 8 4io x 0L F. x L 00 Oi I I L 8 0 CLU 100 Three Phase Substation Secondary Prmary Feeders I• Phase A I I -t L Phase C Common Ti Cto LUIJ...losses. 63 USACERL DISTRIBUTION Chief of Enarmer 4th Infamy Div (MECH) TVADOC US Mslary Aedcmry I(M6 ATTN: CE•IC-lA4-LH 42) ATN: AFZC-FE £1913 ATTN: DEN

  7. Saturation of cyclotron maser instability driven by an electron loss-cone distribution

    NASA Technical Reports Server (NTRS)

    Kuo, S. P.; Lee, M. C.

    1986-01-01

    The resonance diffusion of electrons in velocity space caused by the excited EM wave fields is considered to be the dominant saturation process of cyclotron maser instability that is driven by an electron loss-cone distribution. An upper bound of the saturation level is derived analytically. Since the resulting saturation level is low, the resonance diffusion is indeed responsible for the saturation of the cyclotron maser instability.

  8. Shortening-induced torque depression in old men: implications for age-related power loss.

    PubMed

    Power, Geoffrey A; Makrakos, Demetri P; Stevens, Daniel E; Herzog, Walter; Rice, Charles L; Vandervoort, Anthony A

    2014-09-01

    Following active muscle shortening, the steady-state isometric torque at the final muscle length is lower than the steady-state torque obtained for a purely isometric contraction at that same final muscle length. This well-documented property of skeletal muscle is termed shortening-induced torque depression (TD). Despite many investigations into the mechanisms of weakness and power loss in old age, the influence of muscle shortening on the history dependence of isometric torque production remains to be elucidated. Thus, it is unclear whether older adults are disadvantaged for torque and power production following a dynamic shortening contraction. The purpose of this study was to evaluate shortening-induced TD in older adults, and to determine whether shortening-induced TD is related to power loss. Maximal voluntary isometric dorsiflexion contractions (MVC; 10s) in 8 young (25.5±3.7years) and 9 old (76.1±5.4years) men were performed on a HUMAC NORM dynamometer as a reference, and then again following an active shortening of 40° joint excursion (40°PF-0°PF) at angular velocities of 15°/s and 120°/s. Work and instantaneous power were derived during shortening. Shortening-induced TD was calculated and expressed as a percentage by determining the mean torque value over 1s during the isometric steady state of the MVC following shortening, divided by the mean torque value for the same 1s time period during the isometric reference MVC. To assess muscle activation, electromyography (root mean square; EMGRMS) of the tibialis anterior (TA) and soleus (SOL) was calculated at identical time points used in assessing shortening-induced TD, and voluntary activation (VA) was assessed using the interpolated twitch technique. Old were 18% weaker than young for MVC, and ~40% less powerful for 15°/s and 120°/s of shortening. Old produced 37% and 21% less work for 15°/s and 120°/s than young, respectively. Furthermore, old experienced 60% and 70% greater shortening-induced TD

  9. Use of Transition Modeling to Enable the Computation of Losses for Variable-Speed Power Turbine

    NASA Technical Reports Server (NTRS)

    Ameri, Ali A.

    2012-01-01

    To investigate the penalties associated with using a variable speed power turbine (VSPT) in a rotorcraft capable of vertical takeoff and landing, various analysis tools are required. Such analysis tools must be able to model the flow accurately within the operating envelope of VSPT. For power turbines low Reynolds numbers and a wide range of the incidence angles, positive and negative, due to the variation in the shaft speed at relatively fixed corrected flows, characterize this envelope. The flow in the turbine passage is expected to be transitional and separated at high incidence. The turbulence model of Walters and Leylek was implemented in the NASA Glenn-HT code to enable a more accurate analysis of such flows. Two-dimensional heat transfer predictions of flat plate flow and two-dimensional and three-dimensional heat transfer predictions on a turbine blade were performed and reported herein. Heat transfer computations were performed because it is a good marker for transition. The final goal is to be able to compute the aerodynamic losses. Armed with the new transition model, total pressure losses for three-dimensional flow of an Energy Efficient Engine (E3) tip section cascade for a range of incidence angles were computed in anticipation of the experimental data. The results obtained form a loss bucket for the chosen blade.

  10. Distributed optimal power and rate control in wireless sensor networks.

    PubMed

    Tang, Meiqin; Bai, Jianyong; Li, Jing; Xin, Yalin

    2014-01-01

    With the rapid development of wireless sensor networks, reducing energy consumption is becoming one of the important factors to extend node lifetime, and it is necessary to adjust the launching power of each node because of the limited energy available to the sensor nodes in the networks. This paper proposes a power and rate control model based on the network utility maximization (NUM) framework, where a weighting factor is used to reflect the influence degree of the sending power and transmission rate to the utility function. In real networks, nodes interfere with each other in the procedure of transmitting signal, which may lead to signal transmission failure and may negatively have impacts on networks throughput. Using dual decomposition techniques, the NUM problem is decomposed into two distributed subproblems, and then the conjugate gradient method is applied to solve the optimization problem with the calculation of the Hessian matrix and its inverse in order to guarantee fast convergence of the algorithm. The convergence proof is also provided in this paper. Numerical examples show that the proposed solution achieves significant throughput compared with exiting approaches.

  11. Distributed Optimal Power and Rate Control in Wireless Sensor Networks

    PubMed Central

    Tang, Meiqin; Bai, Jianyong; Li, Jing; Xin, Yalin

    2014-01-01

    With the rapid development of wireless sensor networks, reducing energy consumption is becoming one of the important factors to extend node lifetime, and it is necessary to adjust the launching power of each node because of the limited energy available to the sensor nodes in the networks. This paper proposes a power and rate control model based on the network utility maximization (NUM) framework, where a weighting factor is used to reflect the influence degree of the sending power and transmission rate to the utility function. In real networks, nodes interfere with each other in the procedure of transmitting signal, which may lead to signal transmission failure and may negatively have impacts on networks throughput. Using dual decomposition techniques, the NUM problem is decomposed into two distributed subproblems, and then the conjugate gradient method is applied to solve the optimization problem with the calculation of the Hessian matrix and its inverse in order to guarantee fast convergence of the algorithm. The convergence proof is also provided in this paper. Numerical examples show that the proposed solution achieves significant throughput compared with exiting approaches. PMID:24895654

  12. Fuel cycle comparison of distributed power generation technologies.

    SciTech Connect

    Elgowainy, A.; Wang, M. Q.; Energy Systems

    2008-12-08

    The fuel-cycle energy use and greenhouse gas (GHG) emissions associated with the application of fuel cells to distributed power generation were evaluated and compared with the combustion technologies of microturbines and internal combustion engines, as well as the various technologies associated with grid-electricity generation in the United States and California. The results were primarily impacted by the net electrical efficiency of the power generation technologies and the type of employed fuels. The energy use and GHG emissions associated with the electric power generation represented the majority of the total energy use of the fuel cycle and emissions for all generation pathways. Fuel cell technologies exhibited lower GHG emissions than those associated with the U.S. grid electricity and other combustion technologies. The higher-efficiency fuel cells, such as the solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC), exhibited lower energy requirements than those for combustion generators. The dependence of all natural-gas-based technologies on petroleum oil was lower than that of internal combustion engines using petroleum fuels. Most fuel cell technologies approaching or exceeding the DOE target efficiency of 40% offered significant reduction in energy use and GHG emissions.

  13. Development of a current collection loss management system for SDI homopolar power supplies

    SciTech Connect

    Brown, D.W.

    1989-01-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operate continuously at 2 kA/cm{sup 2}, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To data, no system has achieved these conditions simultaneously. This is the annual report covering the second year period of performance on DOE contract DE-AC03-86SF16518. Major areas covered include design, construction and operation of a cryogenically cooled brush test rig, design and construction of a high speed brush test rig, optimization study for homopolar machines, loss analysis of the current collection system, and an application study which defines the air-core homopolar construction necessary to achieve the goal of 80--90 kW/kg generator power density. 17 figs., 2 tabs.

  14. Impact of high power and angle of incidence on prism corrections for visual field loss

    NASA Astrophysics Data System (ADS)

    Jung, Jae-Hyun; Peli, Eli

    2014-06-01

    Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high-power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results in substantial errors. We analyze the effects of high prism power and incidence angle on the field expansion, size of the apical scotomas, and image compression/expansion. We analyze and illustrate the effects of reflections within the Fresnel prisms, primarily due to reflections at the bases, and secondarily due to surface reflections. The strength and location of these effects differs materially depending on whether the serrated prismatic surface is placed toward or away from the eye, and this affects the contribution of the reflections to visual confusion, diplopia, false alarms, and loss of contrast. We conclude with suggestions for controlling and mitigating these effects in clinical practice.

  15. Development of a current collection loss management system for SDI homopolar power supplies

    NASA Astrophysics Data System (ADS)

    Brown, D. W.

    1991-04-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operate continuously at 2 kA/sq cm, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To date, no system has achieved these conditions simultaneously. This is the final report covering the three year period of performance on DOE contract AC03-86SF-16518. Major areas covered include design, construction and operation of a cryogenically cooled brush test rig, design and construction of a high speed brush test rig, optimization study for homopolar machines, loss analysis of the current collection system, and an application study which defines the air-core homopolar construction necessary to achieve the goal of 80 kW/kg generator power density.

  16. Development of a current collection loss management system for SDI homopolar power supplies

    SciTech Connect

    Hannan, W.F. III.

    1987-01-01

    High speed, high power density current collection systems have been identified as an enabling technology required to construct homopolar power supplies to meet SDI missions. This work is part of a three-year effort directed towards the analysis, experimental verification, and prototype construction of a current collection system designed to operated continuously at 2 kA/cm{sup 2}, at a rubbing speed of 200 m/s, and with acceptable losses in a space environment. To data, no system has achieved these conditions simultaneously. This is the annual report covering the first year period of performance on DOE contract DE-AC03-86SF16518. Major areas covered include design and construction of a cryogenically-cooled brush test rig, design of a high speed brush test rig, loss analysis of the current collection system, and an application study which defines the air core homopolar construction necessary to achieve the goal of 80--90 kW/kg generator power density. 15 figs.

  17. Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review

    SciTech Connect

    Wu, Shuang-Ying; Xiao, Lan; Li, You-Rong; Cao, Yiding

    2010-08-15

    The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. The studies related to those applications may provide valuable information for the solar receiver design, which may otherwise be ignored by a solar system designer. Finally, future development directions and the issues that need to be further investigated are also suggested. It is believed that this comprehensive review will be beneficial to the design, simulation, performance assessment and applications of the solar parabolic dish cavity receivers. (author)

  18. Power law distributions and dynamic behaviour of stock markets

    NASA Astrophysics Data System (ADS)

    Richmond, P.

    2001-04-01

    A simple agent model is introduced by analogy with the mean field approach to the Ising model for a magnetic system. Our model is characterised by a generalised Langevin equation = F ϕ + G ϕ t where t is the usual Gaussian white noise, i.e.: t t' = 2Dδ t-t' and t = 0. Both the associated Fokker Planck equation and the long time probability distribution function can be obtained analytically. A steady state solution may be expressed as P ϕ = exp{ - Ψ ϕ - ln G(ϕ)} where Ψ ϕ = - F/ G dϕ and Z is a normalization factor. This is explored for the simple case where F ϕ = Jϕ + bϕ2 - cϕ3 and fluctuations characterised by the amplitude G ϕ = ϕ + ɛ when it readily yields for ϕ>>ɛ, a distribution function with power law tails, viz: P ϕ = exp{ 2bϕ-cϕ2 /D}. The parameter c ensures convergence of the distribution function for large values of ϕ. It might be loosely associated with the activity of so-called value traders. The parameter J may be associated with the activity of noise traders. Output for the associated time series show all the characteristics of familiar financial time series providing J < 0 and D | J|.

  19. A heuristic nonlinear constructive method for electric power distribution system reconfiguration

    NASA Astrophysics Data System (ADS)

    McDermott, Thomas E.

    1998-12-01

    The electric power distribution system usually operates in a radial configuration, with tie switches between circuits to provide alternate feeds. The losses would be minimized if all switches were closed, but this is not done because it complicates the system's protection against overcurrents. Whenever a component fails, some of the switches must be operated to restore power to as many customers as possible. As loads vary with time, switch operations may reduce losses in the system. Both of these are applications for reconfiguration. The problem is combinatorial, which precludes algorithms that guarantee a global optimum. Most existing reconfiguration algorithms fall into two categories. In the first, branch exchange, the system operates in a feasible radial configuration and the algorithm opens and closes candidate switches in pairs. In the second, loop cutting, the system is completely meshed and the algorithm opens candidate switches to reach a feasible radial configuration. Reconfiguration algorithms based on linearized transshipment, neural networks, heuristics, genetic algorithms, and simulated annealing have also been reported, but not widely used. These existing reconfiguration algorithms work with a simplified model of the power system, and they handle voltage and current constraints approximately, if at all. The algorithm described here is a constructive method, using a full nonlinear power system model that accurately handles constraints. The system starts with all switches open and all failed components isolated. An optional network power flow provides a lower bound on the losses. Then the algorithm closes one switch at a time to minimize the increase in a merit figure, which is the real loss divided by the apparent load served. The merit figure increases with each switch closing. This principle, called discrete ascent optimal programming (DAOP), has been applied to other power system problems, including economic dispatch and phase balancing. For

  20. Simulation of the ohmic loss in photovoltaic laser-power converters for wavelengths of 809 and 1064 nm

    SciTech Connect

    Emelyanov, V. M. Mintairov, S. A.; Sorokina, S. V.; Khvostikov, V. P.; Shvarts, M. Z.

    2016-01-15

    The method of mathematical simulation is used to examine the influence exerted by the characteristics of the epitaxial structure and contact grid of photovoltaic laser-power converters on their ohmic loss. The maximum attainable photoconverter efficiency at a Gaussian distribution of the laser-beam intensity on the surface of a photovoltaic converter and at dark-current densities of p–n junctions typical of structures grown by the metal-organic vapor-phase epitaxy (MOVPE) technique are determined. An approach to finding the optimal parameters of GaAs and In{sub 0.24}Ga{sub 0.76}As/GaAs photovoltaic converters in relation to the optical power being converted is suggested, and the structural parameters for incident-power values of 5, 20, and 50 W at wavelengths of 809 and 1064 nm are determined. It is found that, at laser-light intensities of up to 5 W, >60% efficiency can be achieved in laser-light conversion at a wavelength of 809 nm and >55% efficiency, at a wavelength of 1064 nm.

  1. Design of a power management and distribution system for a thermionic-diode powered spacecraft

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.

    1996-01-01

    The Electrical Systems Development Branch of the Power Technology Division at the NASA Lewis Research Center in Cleveland, Ohio is designing a Power Management and Distribution (PMAD) System for the Air Force's Integrated Solar Upper Stage (ISUS) Engine Ground Test Demonstration (EGD). The ISUS program uses solar-thermal propulsion to perform orbit transfers from Low Earth Orbit (LEO) to Geosynchronous Orbit (GEO) and from LEO to Molnya. The ISUS uses the same energy conversion receiver to perform the LEO to High Earth Orbit (HEO) transfer and to generate on-orbit electric power for the payloads. On-orbit power generation is accomplished via two solar concentrators heating a dual-cavity graphite-core which has Thermionic Diodes (TMD's) encircling each cavity. The graphite core and concentrators together are called the Receiver and Concentrator (RAC). The TDM-emitters reach peak temperatures of approximately 2200K, and the TID-collectors are run at approximately 1000K. Because of the high Specific Impulse (I(sup sp)) of solar thermal propulsion relative to chemical propulsion, and because a common bus is used for communications, GN&C, power, etc., a substantial increase in payload weight is possible. This potentially allows for a stepdown in the required launch vehicle size or class for similar payload weight using conventional chemical propulsion and a separate spacecraft bus. The ISUS power system is to provide 1000W(sub e) at 28+/-6V(sub dc) to the payload/spacecraft from a maximum TID generation capability of 1070W(sub e) at 2200K. Producing power with this quality, protecting the spacecraft from electrical faults and accommodating operational constraints of the TID's are the responsibilities of the PMAD system. The design strategy and system options examined along with the proposed designs for the Flight and EGD configurations are discussed herein.

  2. Gyroharmonic maser instability for weakly relativistic electrons with a loss-cone distribution

    NASA Technical Reports Server (NTRS)

    Yoon, Peter H.; Krauss-Varban, D.

    1990-01-01

    The weakly relativisitic dielectric tensor for a system of electrons comprised of cold and energetic populations, embedded in a neutralizing background, is reformulated in terms of an infinite series representation in powers of lamba = alpha ck(perpendicular)/omega (c), where alpha-squared is a parameter proportional to the average thermal energy of the energetic electrons, k(perpendicular) is the perpendicular component of the wave vector k, and omega (c) is the electron gyrofrequency. The energetic electrons are assumed to have a loss-cone feature in the perpendicular momentum space. The present formalism can be used in the problem of cyclotron maser as well as more general gyroharmonic maser (i.e., multiharmonics) emissions resulting from weakly relativistic loss-cone electrons. This is because, unlike the previous theories in which certain approximations such as the single-harmonic approximations are made, the present formalism retains contributions from the entire harmonics.

  3. Loss Analysis of High Power Stirling-Type Pulse Tube Cryocooler

    NASA Astrophysics Data System (ADS)

    Nakano, K.; Hiratsuka, Y.

    2015-12-01

    For the purpose of cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES) and current fault limiters, cryocoolers should be compact in size, light-weight, and have high efficiency and reliability. In order to meet the demand of HTS devices world-wide, the cryocooler needs to have COP efficiency >0.1. We have developed a high power Stirling-type pulse tube cryocooler (SPTC) with an in-line expander. The experimental results were reported in June 2012[1]. The cooling capacity was 210 W at 77 K and the minimum temperature was 37 K when the compressor input power was 3.8 kW. Accordingly, the COP was about 0.055. To further improve the efficiency, the energy losses in the cryocooler were analyzed. The experimental results and the numerical calculation results are reported in this paper.

  4. Impact of Increasing Distributed Wind Power and Wind Turbine Siting on Rural Distribution Feeder Voltage Profiles: Preprint

    SciTech Connect

    Allen, A.; Zhang, Y. C.; Hodge, B. M.

    2013-09-01

    Many favorable wind energy resources in North America are located in remote locations without direct access to the transmission grid. Building transmission lines to connect remotely-located wind power plants to large load centers has become a barrier to increasing wind power penetration in North America. By connecting utility-sized megawatt-scale wind turbines to the distribution system, wind power supplied to consumers could be increased greatly. However, the impact of including megawatt-scale wind turbines on distribution feeders needs to be studied. The work presented here examined the impact that siting and power output of megawatt-scale wind turbines have on distribution feeder voltage. This is the start of work to present a general guide to megawatt-scale wind turbine impact on the distribution feeder and finding the amount of wind power that can be added without adversely impacting the distribution feeder operation, reliability, and power quality.

  5. Transmission-reflection analysis for localization of temporally successive multipoint perturbations in a distributed fiber-optic loss sensor based on Rayleigh backscattering.

    PubMed

    Spirin, Vasilii V

    2003-03-01

    A novel method is presented for the localization of multipoint loss-inducing perturbations in a distributed fiber-optic sensor. The proposed simple technique is based on measurement of the transmitted and the Rayleigh-backscattered powers of an unmodulated light launched into a sensing fiber. The positions of consecutive perturbations are determined by measuring the slopes of the dependence of normalized Rayleigh-backscattering power versus the square of normalized transmitted power. It is shown that these slopes uniquely depend on the positions of the disturbances along the test fiber. The method allows localization of any number of the perturbations that appear one after another at different positions along the test fiber without ambiguity. Good agreement is obtained between calculated and experimentally measured slopes for a loss that was consecutively induced near the source and remote ends of 2.844-km-long fiber.

  6. Watershed Scale Stable Isotope Distribution and Implications on Soil Organic Carbon Loss Monitoring under Hydrologic Uncertainty

    NASA Astrophysics Data System (ADS)

    Ahmed, I.; Karim, A.; Boutton, T. W.; Strom, K.; Fox, J.

    2013-12-01

    The thematic focus of this 3-year period multidisciplinary USDA-CBG collaborative applied research is integrated monitoring of soil organic carbon (SOC) loss from multi-use lands using state-of-the-art stable isotope science under uncertain hydrologic influences. In this study, SOC loss and water runoff are being monitored on a 150 square kilometer watershed in Houston, Texas, using natural rainfall events, and total organic carbon/nitrogen concentration (TOC/TN) and stable isotope ratio (δ13C, δ15N) measurements with different land-use types. The work presents the interdisciplinary research results to uncover statistically valid and scientifically sound ways to monitor SOC loss by (i) application of Bayesian Markov Chain Monte Carlo statistical models to assess the relationship between rainfall-runoff and SOC release during soil erosion in space and time, (ii) capturing the episodic nature of rainfall events and its role in the spatial distribution of SOC loss from water erosion, (iii) stable isotope composition guided fingerprinting (source and quantity) of SOC by considering various types of erosion processes common in a heterogeneous watershed, to be able to tell what percentage of SOC is lost from various land-use types (Fox and Papanicolaou, 2008), (iv) creating an integrated watershed scale statistical soil loss monitoring model driven by spatial and temporal correlation of flow and stable isotope composition (Ahmed et. al., 2013a,b), and (v) creation of an integrated decision support system (DSS) for sustainable management of SOC under hydrologic uncertainty to assist the end users. References: Ahmed, I., Karim, A., Boutton, T.W., and Strom, K.B. (2013a). 'Monitoring Soil Organic Carbon Loss from Erosion Using Stable Isotopes.' Proc., Soil Carbon Sequestration, International Conference, May 26-29, Reykjavik, Iceland. Ahmed, I, Bouttom, T.W., Strom, K. B., Karim, A., and Irvin-Smith, N. (2013b). 'Soil carbon distribution and loss monitoring in the

  7. Leadership in Mammalian Societies: Emergence, Distribution, Power, and Payoff.

    PubMed

    Smith, Jennifer E; Gavrilets, Sergey; Mulder, Monique Borgerhoff; Hooper, Paul L; El Mouden, Claire; Nettle, Daniel; Hauert, Christoph; Hill, Kim; Perry, Susan; Pusey, Anne E; van Vugt, Mark; Smith, Eric Alden

    2016-01-01

    Leadership is an active area of research in both the biological and social sciences. This review provides a transdisciplinary synthesis of biological and social-science views of leadership from an evolutionary perspective, and examines patterns of leadership in a set of small-scale human and non-human mammalian societies. We review empirical and theoretical work on leadership in four domains: movement, food acquisition, within-group conflict mediation, and between-group interactions. We categorize patterns of variation in leadership in five dimensions: distribution (across individuals), emergence (achieved versus inherited), power, relative payoff to leadership, and generality (across domains). We find that human leadership exhibits commonalities with and differences from the broader mammalian pattern, raising interesting theoretical and empirical issues.

  8. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Kurt Montgomery; Nguyen Minh

    2003-08-01

    This report summarizes the work performed by Honeywell during the October 2001 to December 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The conceptual and demonstration system designs were proposed and analyzed, and these systems have been modeled in Aspen Plus. Work has also started on the assembly of dynamic component models and the development of the top-level controls requirements for the system. SOFC stacks have been fabricated and performance mapping initiated.

  9. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect

    Nguyen Minh

    2002-03-31

    This report summarizes the work performed by Honeywell during the January 2002 to March 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. For this reporting period the following activities have been carried out: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} System-level performance model was created {lg_bullet} Dynamic control models are being developed {lg_bullet} Mechanical properties of candidate heat exchanger materials were investigated {lg_bullet} SOFC performance mapping as a function of flow rate and pressure was completed

  10. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Unknown

    2002-03-01

    This report summarizes the work performed by Honeywell during the July 2001 to September 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. An internal program kickoff was held at Honeywell in Torrance, CA. The program structure was outlined and the overall technical approach for the program was presented to the team members. Detail program schedules were developed and detailed objectives were defined. Initial work has begun on the system design and pressurized SOFC operation.

  11. Spatial variation in water loss predicts terrestrial salamander distribution and population dynamics.

    PubMed

    Peterman, W E; Semlitsch, R D

    2014-10-01

    Many patterns observed in ecology, such as species richness, life history variation, habitat use, and distribution, have physiological underpinnings. For many ectothermic organisms, temperature relationships shape these patterns, but for terrestrial amphibians, water balance may supersede temperature as the most critical physiologically limiting factor. Many amphibian species have little resistance to water loss, which restricts them to moist microhabitats, and may significantly affect foraging, dispersal, and courtship. Using plaster models as surrogates for terrestrial plethodontid salamanders (Plethodon albagula), we measured water loss under ecologically relevant field conditions to estimate the duration of surface activity time across the landscape. Surface activity time was significantly affected by topography, solar exposure, canopy cover, maximum air temperature, and time since rain. Spatially, surface activity times were highest in ravine habitats and lowest on ridges. Surface activity time was a significant predictor of salamander abundance, as well as a predictor of successful recruitment; the probability of a juvenile salamander occupying an area with high surface activity time was two times greater than an area with limited predicted surface activity. Our results suggest that survival, recruitment, or both are demographic processes that are affected by water loss and the ability of salamanders to be surface-active. Results from our study extend our understanding of plethodontid salamander ecology, emphasize the limitations imposed by their unique physiology, and highlight the importance of water loss to spatial population dynamics. These findings are timely for understanding the effects that fluctuating temperature and moisture conditions predicted for future climates will have on plethodontid salamanders.

  12. Structured Coupling of Probability Loss Distributions: Assessing Joint Flood Risk in Multiple River Basins.

    PubMed

    Timonina, Anna; Hochrainer-Stigler, Stefan; Pflug, Georg; Jongman, Brenden; Rojas, Rodrigo

    2015-11-01

    Losses due to natural hazard events can be extraordinarily high and difficult to cope with. Therefore, there is considerable interest to estimate the potential impact of current and future extreme events at all scales in as much detail as possible. As hazards typically spread over wider areas, risk assessment must take into account interrelations between regions. Neglecting such interdependencies can lead to a severe underestimation of potential losses, especially for extreme events. This underestimation of extreme risk can lead to the failure of riskmanagement strategies when they are most needed, namely, in times of unprecedented events. In this article, we suggest a methodology to incorporate such interdependencies in risk via the use of copulas. We demonstrate that by coupling losses, dependencies can be incorporated in risk analysis, avoiding the underestimation of risk. Based on maximum discharge data of river basins and stream networks, we present and discuss different ways to couple loss distributions of basins while explicitly incorporating tail dependencies. We distinguish between coupling methods that require river structure data for the analysis and those that do not. For the later approach we propose a minimax algorithm to choose coupled basin pairs so that the underestimation of risk is avoided and the use of river structure data is not needed. The proposed methodology is especially useful for large-scale analysis and we motivate and apply our method using the case of Romania. The approach can be easily extended to other countries and natural hazards.

  13. Associations between Obesity, Body Fat Distribution, Weight Loss and Weight Cycling on Serum Pesticide Concentrations

    PubMed Central

    Frugé, Andrew Dandridge; Cases, Mallory Gamel; Schildkraut, Joellen Martha; Demark-Wahnefried, Wendy

    2016-01-01

    Objective Preliminary studies suggest pesticides may be linked to increased cancer risk. Since most pesticides are lipophilic and stored within adipose tissue, serum levels of organochlorines are affected not only by environmental exposures, but also by factors related to lipid turnover and storage. Our objective was to investigate whether serum organochlorines are influenced by weight loss, body fat distribution, and weight cycling. Methods Ten overweight women were recruited upon entry into a weight loss program and surveyed regarding weight history, childbearing/lactation, and exposure to environmental contaminants. Anthropometric measures and phlebotomy were conducted at baseline and at four weeks (mean weight loss=5.1 kg). Serum was analyzed for 19 common polychlorinated pesticides and metabolites and 10 PCB congeners. Results Organochlorine levels were not significantly affected by weight loss nor associated with body mass index (BMI). Strong positive correlations were noted between levels of DDE/DDT and age (DDE β=0.6986/p=0.0246/DDT β=0.6536/p=0.0404) and between DDE/DDT and waist-to-hip ratio (WHR) (DDE β=0.4356/p=0.0447/DDT β=0.8108/p=0.0044). Trends were noted for decreased levels of DDT in women who reported more episodes of weight cycling. Conclusion Serum organochlorine levels may be affected not only by age, but also factors related to lipid turnover (i.e., episodes of weight cycling and WHR), and warrants further study. PMID:27478857

  14. Measurements of the Ech Power and of the Transmission Line Losses on Diii-D

    NASA Astrophysics Data System (ADS)

    Cengher, M.; Lohr, J.; Gorelov, I. A.; Grosnickle, W. H.; Ponce, D.; Johnson, P.

    2009-04-01

    The measurement of the power injected by the electron cyclotron heating (ECH) system in the DIII-D tokamak is a critical requirement for analysis of experiments, for tuning the gyrotrons for maximum power and efficiency, for tracking long-term operational trends and for providing a warning of problems with the system. The ECH system at General Atomics consists of six 110 GHz, 1 MW class gyrotrons. The rf power generated by each gyrotron is determined from calorimetry, using the relevant temperature and flow measurements from the cooling circuits of cavity, matching optics unit and dummy loads. The rf pulse length and time dependence are measured using an rf monitor at the first miter bend in the transmission line. The direct measurement of the efficiencies of four of the transmission lines was performed using a high power, small dummy load (SDL) placed alternately in 2 positions of each DIII-D waveguide line, at accessible points close the beginning and the end of each line. Total losses in the transmission lines range from 21.2% to 30.7%. Experimental results are compared to theoretical predictions of the performance of the components and waveguide lines.

  15. The impact of distributed generation on the Thailand's electric power system

    NASA Astrophysics Data System (ADS)

    Fuangfoo, Pradit

    Typically, subtransmission and distribution systems are a radial configuration and have only one source from a main grid. The subtransmission and distribution systems are usually not designed to operate with the Distributed Generation (DG) connecting to the systems. In recent years, the installation capacity of DG has increased significantly in the Electrical Power System (EPS), particularly in the subtransmission and distribution systems due to the economical and technical benefits associated with DG such as higher efficiencies, reduced system losses, and enhanced system reliability. If the penetration level of DG continues to increase while the EPS remain unchanged, technical conflicts may develop in the future. In this dissertation, the impact study focuses on the Thailand's EPS. The research performs systematic approach to evaluate the impact of DG on the whole Thailand's ESP and on the local system (subtransmission and distribution systems). This dissertation investigates the effect of DG on both steady-stead and dynamic performance of the whole system. The influence of penetration level together with types and operation modes of DGs are also included. The steady-state study analyzes the effect of DG on voltage profile, system losses, and transmission line usages during normal and abnormal condition, whereas the dynamic impact concentrates on the effect of DG on dynamic stability and small signal stability. The investigated results can be drawn into the policy to determine the maximum penetration level of DG spread out the whole system to avoid the adverse effect from DG. Similarly, the impact study of DG on local system (subtransmission and distribution system) also includes the influence of DG on steady-state and dynamic performance of the system. The steady-state impact of DG on local system focuses on voltage profile, system losses, protection coordination, harmonics, and system reliability. For dynamic impact of DG on local system, the main concern is

  16. C -parameter distribution at N3LL' including power corrections

    NASA Astrophysics Data System (ADS)

    Hoang, André H.; Kolodrubetz, Daniel W.; Mateu, Vicent; Stewart, Iain W.

    2015-05-01

    We compute the e+e- C -parameter distribution using the soft-collinear effective theory with a resummation to next-to-next-to-next-to-leading-log prime accuracy of the most singular partonic terms. This includes the known fixed-order QCD results up to O (αs3), a numerical determination of the two-loop nonlogarithmic term of the soft function, and all logarithmic terms in the jet and soft functions up to three loops. Our result holds for C in the peak, tail, and far tail regions. Additionally, we treat hadronization effects using a field theoretic nonperturbative soft function, with moments Ωn. To eliminate an O (ΛQCD) renormalon ambiguity in the soft function, we switch from the MS ¯ to a short distance "Rgap" scheme to define the leading power correction parameter Ω1. We show how to simultaneously account for running effects in Ω1 due to renormalon subtractions and hadron-mass effects, enabling power correction universality between C -parameter and thrust to be tested in our setup. We discuss in detail the impact of resummation and renormalon subtractions on the convergence. In the relevant fit region for αs(mZ) and Ω1, the perturbative uncertainty in our cross section is ≃ 2.5 % at Q =mZ.

  17. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect

    Faress Rahman; Nguyen Minh

    2003-07-01

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC during the January 2003 to June 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. This report summarizes the results obtained to date on: System performance analysis and model optimization; Reliability and cost model development; System control including dynamic model development; Heat exchanger material tests and life analysis; Pressurized SOFC evaluation; and Pre-baseline system definition for coal gasification fuel cell system concept.

  18. C -parameter distribution at N 3 LL ' including power corrections

    DOE PAGES

    Hoang, André H.; Kolodrubetz, Daniel W.; Mateu, Vicent; ...

    2015-05-15

    We compute the e⁺e⁻ C-parameter distribution using the soft-collinear effective theory with a resummation to next-to-next-to-next-to-leading-log prime accuracy of the most singular partonic terms. This includes the known fixed-order QCD results up to O(α3s), a numerical determination of the two-loop nonlogarithmic term of the soft function, and all logarithmic terms in the jet and soft functions up to three loops. Our result holds for C in the peak, tail, and far tail regions. Additionally, we treat hadronization effects using a field theoretic nonperturbative soft function, with moments Ωn. To eliminate an O(ΛQCD) renormalon ambiguity in the soft function, we switchmore » from the MS¯ to a short distance “Rgap” scheme to define the leading power correction parameter Ω1. We show how to simultaneously account for running effects in Ω1 due to renormalon subtractions and hadron-mass effects, enabling power correction universality between C-parameter and thrust to be tested in our setup. We discuss in detail the impact of resummation and renormalon subtractions on the convergence. In the relevant fit region for αs(mZ) and Ω1, the perturbative uncertainty in our cross section is ≅ 2.5% at Q=mZ.« less

  19. In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing: Preprint

    SciTech Connect

    Spataru, Sergiu; Hacke, Pater; Sera, Dezso

    2015-09-15

    We analyze the degradation of multi-crystalline silicon photovoltaic modules undergoing simultaneous thermal, mechanical, and humidity stress testing to develop a dark environmental chamber in-situ measurement procedure for determining module power loss. From the analysis we determine three main categories of failure modes associated with the module degradation consisting of: shunting, recombination losses, increased series resistance losses, and current mismatch losses associated with a decrease in photo-current generation by removal of some cell areas due to cell fractures. Based on the analysis, we propose an in-situ module power loss monitoring procedure that relies on dark current-voltage measurements taken during the stress test, and initial and final module flash testing, to determine the power degradation characteristic of the module.

  20. Distributed beam loss monitor based on the Cherenkov effect in an optical fiber

    NASA Astrophysics Data System (ADS)

    Maltseva, Yu; Emanov, F. A.; Petrenko, A. V.; Prisekin, V. G.

    2015-05-01

    This review discusses a distributed beam loss monitor which is based on the Cherenkov effect in an optical fiber and which has been installed at the VEPP-5 Injection Complex at the Budker Institute of Nuclear Physics. The principle of the device operation consists in detecting the Cherenkov radiation generated in an optical fiber by relativistic charged particles that are produced in an electromagnetic shower when highly relativistic beam particles (electrons or positrons) hit the accelerator vacuum chamber wall. Our experiments used a photomultiplier tube (PMT) to detect the Cherenkov light. Knowing when the PMT signal arrives tells us where the beam loss occurs. Using a 20-m-long optical fiber allowed a detector spatial resolution of 3 m. The way to improve the resolution is to optimize the monitor working conditions and optical fiber and PMT parameters, potentially leading to a resolution of as fine as 0.5 m according to our estimates.

  1. A distributed optical fiber sensing system for synchronous vibration and loss measurement

    NASA Astrophysics Data System (ADS)

    Zhang, Xu-ping; Qiao, Wei-yan; Sun, Zhen-hong; Shan, Yuan-yuan; Zeng, Jie; Zhang, Yi-xin

    2016-09-01

    We propose a fully distributed fusion system combining phase-sensitive optical time-domain reflectometry (Φ-OTDR) and OTDR for synchronous vibration and loss measurement by setting an ingenious frequency sweep rate ( FSR) of the optical source. The relationships between FSR, probe pulse width and repeat period are given to balance the amplitude fluctuation of OTDR traces, the dead zone probability and the measurable frequency range of vibration events. In the experiment, we achieve synchronous vibration and loss measurement with FSR of 40 MHz/s, the proble pulse width of 100 ns and repeat rate of 0.4 ms. The fluctuation of OTDR trace is less than 0.45 dB when the signal-to-noise ratio ( SNR) is over 12 dB for a captured vibration event located at 9.1 km. The proposed method can be used for not only detection but also early warning of damage events in optical communication networks.

  2. A reformer to generate hydrogen for distributed power applications

    SciTech Connect

    Cole, J.A.; Kumar, R.V.; West, J.; Lyon, R.K.

    1998-07-01

    The generation of power using fuel cells is a promising technology for distributed electric power generation applications. Steam reforming of fossil fuels remains the most thermodynamically efficient means for production of hydrogen. Unfortunately, current steam reforming technology achieves high efficiencies only at very large scales, and remains impractical at the small production rates needed for small- to medium-size distributed power applications. A novel reformer process, called unmixed reforming, or UMR, has been developed for the conversion of hydrocarbon fuels (natural gas, diesel, gasoline) to hydrogen. The reformer promises high thermodynamic efficiency as heat is generated right on the catalytic bed unlike conventional reforming. The controlled combustion on the reforming catalyst using a patented technology called unmixed combustion provides the heat for the endothermic reforming reaction. The reformer generates a high-purity hydrogen product stream, which can then be used by fuel cells with minimal processing. The unmixed reformer is a packed-bed consisting of finely divided nickel supported on a ceramic matrix mixed with a calcium oxide bearing matrix such as dolomite. UMR consists of three process steps. During the first step air is passed over the packed-bed reactor to oxidize the nickel. The heat released during the oxidation reaction raises the temperature of the bed and decomposes the dolomite releasing carbon dioxide into a vent gas stream. In the subsequent step fuel passed over the packed-bed reduces the NiO back to Ni and further increases the temperature. In the final step, fuel and steam react to produce hydrogen through conventional steam reforming chemistry. The calcium oxide captures some of the carbon dioxide formed during the reforming reaction and thus shifts the reforming reactions to higher conversions, hence improving the purity of the hydrogen product stream. Although product hydrogen concentrations may be 75--85%, the CO content

  3. Complex additive systems for Mn-Zn ferrites with low power loss

    SciTech Connect

    Töpfer, J. Angermann, A.

    2015-05-07

    Mn-Zn ferrites were prepared via an oxalate-based wet-chemical synthesis process. Nanocrystalline ferrite powders with particle size of 50 nm were sintered at 1150 °C with 500 ppm CaO and 100 ppm SiO{sub 2} as standard additives. A fine-grained, dense microstructure with grain size of 4–5 μm was obtained. Simultaneous addition of Nb{sub 2}O{sub 5}, ZrO{sub 2}, V{sub 2}O{sub 5}, and SnO{sub 2} results low power losses, e.g., 65 mW/cm{sup 3} (500 kHz, 50 mT, 80 °C) and 55 mW/cm{sup 3} (1 MHz, 25 mT, 80 °C). Loss analysis shows that eddy current and residual losses were minimized through formation of insulating grain boundary phases, which is confirmed by transmission electron microscopy. Addition of SnO{sub 2} increases the ferrous ion concentration and affects anisotropy as reflected in permeability measurements μ(T)

  4. Power law olivine crystal size distributions in lithospheric mantle xenoliths

    NASA Astrophysics Data System (ADS)

    Armienti, P.; Tarquini, S.

    2002-12-01

    Olivine crystal size distributions (CSDs) have been measured in three suites of spinel- and garnet-bearing harzburgites and lherzolites found as xenoliths in alkaline basalts from Canary Islands, Africa; Victoria Land, Antarctica; and Pali Aike, South America. The xenoliths derive from lithospheric mantle, from depths ranging from 80 to 20 km. Their textures vary from coarse to porphyroclastic and mosaic-porphyroclastic up to cataclastic. Data have been collected by processing digital images acquired optically from standard petrographic thin sections. The acquisition method is based on a high-resolution colour scanner that allows image capturing of a whole thin section. Image processing was performed using the VISILOG 5.2 package, resolving crystals larger than about 150 μm and applying stereological corrections based on the Schwartz-Saltykov algorithm. Taking account of truncation effects due to resolution limits and thin section size, all samples show scale invariance of crystal size distributions over almost three orders of magnitude (0.2-25 mm). Power law relations show fractal dimensions varying between 2.4 and 3.8, a range of values observed for distributions of fragment sizes in a variety of other geological contexts. A fragmentation model can reproduce the fractal dimensions around 2.6, which correspond to well-equilibrated granoblastic textures. Fractal dimensions >3 are typical of porphyroclastic and cataclastic samples. Slight bends in some linear arrays suggest selective tectonic crushing of crystals with size larger than 1 mm. The scale invariance shown by lithospheric mantle xenoliths in a variety of tectonic settings forms distant geographic regions, which indicate that this is a common characteristic of the upper mantle and should be taken into account in rheological models and evaluation of metasomatic models.

  5. Exponential and power-law mass distributions in brittle fragmentation

    NASA Astrophysics Data System (ADS)

    Åström, J. A.; Linna, R. P.; Timonen, J.; Møller, Peder Friis; Oddershede, Lene

    2004-08-01

    Generic arguments, a minimal numerical model, and fragmentation experiments with gypsum disk are used to investigate the fragment-size distribution that results from dynamic brittle fragmentation. Fragmentation is initiated by random nucleation of cracks due to material inhomogeneities, and its dynamics are pictured as a process of propagating cracks that are unstable against side-branch formation. The initial cracks and side branches both merge mutually to form fragments. The side branches have a finite penetration depth as a result of inherent damping. Generic arguments imply that close to the minimum strain (or impact energy) required for fragmentation, the number of fragments of size s scales as s-(2D-1)/Df1(-(2/λ)Ds)+f2(-s0-1(λ+s1/D)D) , where D is the Euclidean dimension of the space, λ is the penetration depth, and f1 and f2 can be approximated by exponential functions. Simulation results and experiments can both be described by this theoretical fragment-size distribution. The typical largest fragment size s0 was found to diverge at the minimum strain required for fragmentation as it is inversely related to the density of initially formed cracks. Our results also indicate that scaling of s0 close to this divergence depends on, e.g., loading conditions, and thus is not universal. At the same time, the density of fragment surface vanishes as L-1 , L being the linear dimension of the brittle solid. The results obtained provide an explanation as to why the fragment-size distributions found in nature can have two components, an exponential as well as a power-law component, with varying relative weights.

  6. Aging Management Guideline for commercial nuclear power plants: Power and distribution transformers

    SciTech Connect

    Toman, G.; Gazdzinski, R.

    1994-05-01

    This Aging Management Guideline (AMG) provides recommended methods for effective detection and mitigation of age-related degradation mechanisms in power and distribution transformers important to license renewal in commercial nuclear power plants. The intent of this AMG to assist plant maintenance and operations personnel in maximizing the safe, useful life of these components. It also supports the documentation of effective aging management programs required under the License Renewal Rule 10 CFR Part 54. This AMG is presented in a manner which allows personnel responsible for performance analysis and maintenance to compare their plant-specific aging mechanisms (expected or already experienced) and aging management program activities to the more generic results and recommendations presented herein.

  7. Poynting flux in the neighbourhood of a point charge in arbitrary motion and radiative power losses

    NASA Astrophysics Data System (ADS)

    Singal, Ashok K.

    2016-07-01

    We examine the electromagnetic fields in the neighbourhood of a ‘point charge’ in arbitrary motion and thereby determine the Poynting flux across a spherical surface of vanishingly small radius surrounding the charge. We show that the radiative power losses from a point charge turn out to be proportional to the scalar product of the instantaneous velocity and the first time-derivative of the acceleration of the charge. This may seem to be discordant with the familiar Larmor formula where the instantaneous power radiated from a charge is proportional to the square of acceleration. However, it seems that the root cause of the discrepancy actually lies in Larmor’s formula, which is derived using the acceleration fields but without due consideration for the Poynting flux associated with the velocity-dependent self-fields ‘co-moving’ with the charge. Further, while deriving Larmor’s formula, one equates the Poynting flux through a surface at some later time to the radiation loss by the enclosed charge at the retarded time. Poynting’s theorem, on the other hand, relates the outgoing radiation flux from a closed surface to the rate of energy decrease within the enclosed volume, all calculated for the same given instant only. Here we explicitly show the absence of any Poynting flux in the neighbourhood of an instantly stationary point charge, implying no radiative losses from such a charge, which is in complete conformity with energy conservation. We further show how Larmor’s formula is still able to serve our purpose in the vast majority of cases. It is further shown that Larmor’s formula in general violates momentum conservation and, in the case of synchrotron radiation, leads to a potentially incorrect conclusion about the pitch angle changes of the radiating charges, and that only the radiation reaction formula yields a correct result, consistent with special relativity.

  8. Practical Considerations For Optical Power Loss Measurements During Outside Plant Installations

    NASA Astrophysics Data System (ADS)

    Grebe, Robert K.; Caron, Bernard G.

    1984-08-01

    The techniques for predicting total transmission system losses in a fiber optic cable installation involving multiple splices are relatively well known, and significant work has been done in the field of laboratory measurement techniques for quantifying cable (fiber) characteristics and performance characteristics of splices and connectors. The shift of this technology from the laboratory to the actual environment of a field installation, however, poses some significantly different problems to the user of fiber optic cables and splices. The basic instrument available for field use in testing optical links is the Optical-Time-Domain-Reflectometer (OTDR). An OTDR can be used to check the loss profile (dB/km) of a fiber within a cable prior to the cable installation, and to locate installation induced faults in the cable. The capability of the OTDR above to characterize splice losses in an actual installation can be significantly degraded depending on the location of the splice with respect to cable faults, the length of the cable (fiber) run, the characteristics of the individual fibers being spliced, and the ability of the OTDR operator to interpret the-data the instrument is presenting. By following some specific procedures regarding the sequence of installation and testing, and through better understanding of the performance of optical fibers and splices where actually installed in the outside plant environment, installation crews can significantly reduce installation time and time lost because of faults in an individual link that must be reworked. Addi-tional testing with instruments specifically intended for optical power measurement can provide a realistic basis for evaluation of the overall performance of a completely installed link and will give the transmission engineer a solid reference base for use in system set-up in addition to evaluation of system deterioration. Records made through OTDR measurements and optical power instrument readings can be used to

  9. Validating MCNP for LEU Fuel Design via Power Distribution Comparisons

    SciTech Connect

    Primm, Trent; Maldonado, G Ivan; Chandler, David

    2008-11-01

    The mission of the Reduced Enrichment for Research and Test Reactors (RERTR) Program is to minimize and, to the extent possible, eliminate the use of highly enriched uranium (HEU) in civilian nuclear applications by working to convert research and test reactors, as well as radioisotope production processes, to low enriched uranium (LEU) fuel and targets. Oak Ridge National Lab (ORNL) is reviewing the design bases and key operating criteria including fuel operating parameters, enrichment-related safety analyses, fuel performance, and fuel fabrication in regard to converting the fuel of the High Flux Isotope Reactor (HFIR) from HEU to LEU. The purpose of this study is to validate Monte Carlo methods currently in use for conversion analyses. The methods have been validated for the prediction of flux values in the reactor target, reflector, and beam tubes, but this study focuses on the prediction of the power density profile in the core. A current 3-D Monte Carlo N-Particle (MCNP) model was modified to replicate the HFIR Critical Experiment 3 (HFIRCE-3) core of 1965. In this experiment, the power profile was determined by counting the gamma activity at selected locations in the core. Foils (chunks of fuel meat and clad) were punched out of the fuel elements in HFIRCE-3 following irradiation and experimental relative power densities were obtained by measuring the activity of these foils and comparing each foil s activity to the activity of a normalizing foil. The current work consisted of calculating corresponding activities by inserting volume tallies into the modified MCNP model to represent the punchings. The average fission density was calculated for each foil location and then normalized to the normalizing foil. Power distributions were obtained for the clean core (no poison in moderator and symmetrical rod position at 17.5 inches) and fully poisoned-moderator (1.35 g B/liter in moderator and rods fully withdrawn) conditions. The observed deviations between the

  10. Creating markets for combined heat and power and clean distributed generation in New York State.

    PubMed

    Bourgeois, Thomas G; Hedman, Bruce; Zalcman, Fred

    2003-01-01

    Combined heat and power (CHP) is the simultaneous production of electrical or mechanical power and thermal energy from in a single process. Because thermal output from the generation of electricity is captured and utilized onsite, CHP systems can achieve efficiencies from 60% to as high as 90%. In contrast generation of electric power at sites remote from the loads served often results in efficiencies of 33% or less due to losses in generation and transmission and distribution of the power to ultimate end users. A well designed CHP system is the essence of energy efficiency. It may also provide significant environmental benefits. However, the full promise of CHP for improving the efficiency and productivity of businesses and the quality of the environment is unlikely to be realized given the current market structure and regulatory environment in which CHP projects are forced to compete. This paper examines the market structure and regulatory obstacles that hinder the development of more robust markets for CHP in New York State.

  11. LIQHYSMES - spectral power distributions of imbalances and implications for the SMES

    NASA Astrophysics Data System (ADS)

    Sander, M.; Gehring, R.; Neumann, H.

    2014-05-01

    LIQHYSMES, the recently proposed hybrid energy storage concept for variable renewable energies, combines the storage of LIQuid HYdrogen (LH2) with Superconducting Magnetic Energy Storage (SMES). LH2 as the bulk energy carrier is used for the large scale stationary longer-term energy storage, and the SMES cooled by the LH2 bath, provides highest power over shorter periods and at superior efficiencies. Both together contribute to the balancing of electric load or supply fluctuations from seconds to several hours, days or even weeks. Here different spectral power distributions of such imbalances between electricity supply and load reflecting different sources of fluctuations in the range between 1 sec and 15 minutes are considered. Some related implications for MgB2-based 100 MW-SMES operated at maximum fields of 2 T and 4 T, are considered for these buffering scenarios. Requirements as regards the storage capacity and correspondingly the minimum size of the LH2 storage tank are derived. The related loss contributions with a particular focus on the ramping losses are analysed.

  12. Partial Shade Evaluation of Distributed Power Electronics for Photovoltaic Systems: Preprint

    SciTech Connect

    Deline, C.; Meydbrav, J.; Donovan, M.

    2012-06-01

    Site survey data for several residential installations are provided, showing the extent and frequency of shade throughout the year. This background information is used to design a representative shading test that is conducted on two side-by-side 8-kW photovoltaic (PV) installations. One system is equipped with a standard string inverter, while the other is equipped with microinverters on each solar panel. Partial shade is applied to both systems in a comprehensive range of shading conditions, simulating one of three shade extents. Under light shading conditions, the microinverter system produced the equivalent of 4% annual performance improvement, relative to the string inverter system. Under moderate shading conditions, the microinverter system outperformed the string inverter system by 8%, and under heavy shading the microinverter increased relative performance by 12%. In all three cases, the percentage of performance loss that is recovered by the use of distributed power electronics is 40%-50%. Additionally, it was found that certain shading conditions can lead to additional losses in string inverters due to peak-power tracking errors and voltage limitations.

  13. [Temporal and spatial distribution characteristics of nitrogen losses in hilly area of Taihu Lake].

    PubMed

    Wang, Peng; Gao, Chao; Yao, Qi; Han, Long-Xi; Shen, Xia

    2006-08-01

    Four typical land uses in hilly area of Taihu Lake were studied on temporal and spatial distribution characteristics of nitrogen losses in surface runoff under natural rainfall through experiment in situ. The medium value of event mean concentration (EMC) of ammonia nitrogen (NH4(+) -N) which dominated agricultural N in surface runoff accounted for 44.5% of total nitrogen (TN), while nitrite nitrogen (NO2(-) -N) accounted for 1.8%. Concentration of nitrogen in runoff had significantly seasonal variation which was related to meteorologic conditions such as rainfall, temperature, and agricultural activities. Temporal variabilities of site mean concentration (SMC) for TN, NH4(+) -N, NO3(-) -N and NO2(-) -N were decreased sequentially. The highest SMC value of TN, NH(+) -N and NO3(-) -N in upland runoff and N2(-) -N in bamboo grove were observed. The spatial distribution of nitrogen losses was determined by fertilizer application and vegetation coverage. Spatial variabilities for SMC of nitrogen were less than temporal variabilities. It was found that transportation fluxes of nitrogen in surface runoff from upland and vegetable plot were higher than that from chestnut orchard and bamboo forest which have significantly related to surface runoff volume.

  14. The place of solar power: an economic analysis of concentrated and distributed solar power

    PubMed Central

    2012-01-01

    Background This paper examines the cost and benefits, both financial and environmental, of two leading forms of solar power generation, grid-tied photovoltaic cells and Dish Stirling Systems, using conventional carbon-based fuel as a benchmark. Methods First we define how these solar technologies will be implemented and why. Then we delineate a model city and its characteristics, which will be used to test the two methods of solar-powered electric distribution. Then we set the constraining assumptions for each technology, which serve as parameters for our calculations. Finally, we calculate the present value of the total cost of conventional energy needed to power our model city and use this as a benchmark when analyzing both solar models’ benefits and costs. Results The preeminent form of distributed electricity generation, grid-tied photovoltaic cells under net-metering, allow individual homeowners a degree of electric self-sufficiency while often turning a profit. However, substantial subsidies are required to make the investment sensible. Meanwhile, large dish Stirling engine installations have a significantly higher potential rate of return, but face a number of pragmatic limitations. Conclusions This paper concludes that both technologies are a sensible investment for consumers, but given that the dish Stirling consumer receives 6.37 dollars per watt while the home photovoltaic system consumer receives between 0.9 and 1.70 dollars per watt, the former appears to be a superior option. Despite the large investment, this paper deduces that it is far more feasible to get few strong investors to develop a solar farm of this magnitude, than to get 150,000 households to install photovoltaic arrays in their roofs. Potential implications of the solar farm construction include an environmental impact given the size of land require for this endeavour. However, the positive aspects, which include a large CO2 emission reduction aggregated over the lifespan of the farm

  15. Space vehicle electrical power processing distribution and control study. Volume 1: Summary

    NASA Technical Reports Server (NTRS)

    Krausz, A.

    1972-01-01

    A concept for the processing, distribution, and control of electric power for manned space vehicles and future aircraft is presented. Emphasis is placed on the requirements of the space station and space shuttle configurations. The systems involved are referred to as the processing distribution and control system (PDCS), electrical power system (EPS), and electric power generation system (EPGS).

  16. Wind Power Forecasting Error Distributions over Multiple Timescales: Preprint

    SciTech Connect

    Hodge, B. M.; Milligan, M.

    2011-03-01

    In this paper, we examine the shape of the persistence model error distribution for ten different wind plants in the ERCOT system over multiple timescales. Comparisons are made between the experimental distribution shape and that of the normal distribution.

  17. The distribution of absorptive power dissipation in irradiated nanoparticulate system

    NASA Astrophysics Data System (ADS)

    Li, Jiayu; Yang, Jian; Gu, Xiaobing

    2016-10-01

    The knowledge of local radiant absorption is important to the nanostructure optimization, it is beneficial to the applications in energy harvesting, optical heating, photocatalysis, etc. In this paper, FDTD model is constructed for the distribution of absorptive power dissipation in irradiated nanoparticulate system. The theoretical model extended from Mie theory is used to examine the FDTD model, the parameters and conditions set for FDTD simulation are confirmed based on the comparison. Then, the influence of Ag nanoparticle on the absorptive properties of nearby TiO2 nanoparticle is investigated by FDTD simulation at the wavelength of 0.25 μm. It is indicated that suitable distance between TiO2 and Ag particles is beneficial to the spectral radiant absorption of TiO2 particle. Considering the agglomeration of nanoparticles and the oxidation at the TiO2-Ag interface, the Ag core coated with Al2O3 shell is suggested, and the simulated results indicated that the shell thickness and the Ag core size need to be optimized for enhancing the radiant absorption of TiO2 particle.

  18. RHF RELAP5 model and preliminary loss-of-offsite-power simulation results for LEU conversion

    SciTech Connect

    Licht, J. R.; Bergeron, A.; Dionne, B.; Thomas, F.

    2014-08-01

    The purpose of this document is to describe the current state of the RELAP5 model for the Institut Laue-Langevin High Flux Reactor (RHF) located in Grenoble, France, and provide an update to the key information required to complete, for example, simulations for a loss of offsite power (LOOP) accident. A previous status report identified a list of 22 items to be resolved in order to complete the RELAP5 model. Most of these items have been resolved by ANL and the RHF team. Enough information was available to perform preliminary safety analyses and define the key items that are still required. Section 2 of this document describes the RELAP5 model of RHF. The final part of this section briefly summarizes previous model issues and resolutions. Section 3 of this document describes preliminary LOOP simulations for both HEU and LEU fuel at beginning of cycle conditions.

  19. An experimental study of energy loss mechanisms and efficiency considerations in the low power dc arcjet

    NASA Technical Reports Server (NTRS)

    Curran, F. M.

    1985-01-01

    The potential utility of the low power dc arcjet in auxiliary propulsion was investigated. It was indicated that improvements in the areas of stability, energy efficiency, reliability, and electrode erosion are necessary to obtain a useful device. A water-cooled arcjet simulator was tested to investigate both the energy loss mechanisms at the electrodes and the stability of different conventional arcjet configurations in the presence of a vortex flow field. It is shown that in certain configurations only 25 to 30 percent of the input energy is lost to the electrodes. It is also shown that vortex stabilization is not difficult to obtain in many cases at the flow rates used and that a careful starting procedure is effective in minimizing electrode damage.

  20. An experimental study of energy loss mechanisms and efficiency consideration in the low power dc arcjet

    NASA Technical Reports Server (NTRS)

    Curran, F. M.

    1985-01-01

    The potential utility of the low power dc arcjet in auxiliary propulsion was investigated. It was indicated that improvements in the areas of stability, energy efficiency, reliability, and electrode erosion are necessary to obtain a useful device. A water-cooled arcjet simulator was tested to investigate both the energy loss mechanisms at the electrodes and the stability of different conventional arcjet configurations in the presence of a vortex flow field. It is shown that in certain configurations only 25 to 30% of the input energy is lost to the electrodes. It is also shown that vortex stabilization is not difficult to obtain in many cases at the flow rates used and that a careful starting procedure is effective in minimizing electrode damage.

  1. Distributed solid state programmable thermostat/power controller

    NASA Technical Reports Server (NTRS)

    Alexander, Jane C. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2008-01-01

    A self-contained power controller having a power driver switch, programmable controller, communication port, and environmental parameter measuring device coupled to a controllable device. The self-contained power controller needs only a single voltage source to power discrete devices, analog devices, and the controlled device. The programmable controller has a run mode which, when selected, upon the occurrence of a trigger event changes the state of a power driver switch and wherein the power driver switch is maintained by the programmable controller at the same state until the occurrence of a second event.

  2. Determination analaysis of the power losses of transformers with continuously transpored conductors (CTC) based fuzzy logic

    NASA Astrophysics Data System (ADS)

    Kaloko, Bambang Sri; Atsari, Erinna Dyah

    2017-03-01

    Electric motive force which flows into the iron core continuously on a plate - plate iron isolated may cause heat posed by current eddy (eddy current). No water loss occurs due to detainees on the circuit at the the flow of current load because this loss happened on the entanglement of the transformer is made of copper. Continuously Transposed Conductors (CTC) consist of a number of enameled rectangular wires (5-84 strands) made into an assembly. Each strand is transposed in turn to each position in the cable and is then covered with layers of insulation paper. Continuously Transposed Conductors are used in winding wires for medium and ultra high power transformers. CTC is manufactured by OFHC copper and indeed, is able to supply polyester roped. CTC which has been designed to reduce production cost, oil pocket and improve cooling efficiency. Hardened type CTC (CPR1, CPR2, and CPR3: BS1432) and Self-bonding CTC which can be used to improve mechanical and electrical strength are also available. This analysis is performed using the methods of fuzzy logic in taking account of the resources.

  3. Power requirement of the geodynamo from ohmic losses in numerical and laboratory dynamos.

    PubMed

    Christensen, Ulrich R; Tilgner, Andreas

    2004-05-13

    In the Earth's fluid outer core, a dynamo process converts thermal and gravitational energy into magnetic energy. The power needed to sustain the geomagnetic field is set by the ohmic losses (dissipation due to electrical resistance). Recent estimates of ohmic losses cover a wide range, from 0.1 to 3.5 TW, or roughly 0.3-10% of the Earth's surface heat flow. The energy requirement of the dynamo puts constraints on the thermal budget and evolution of the core through Earth's history. Here we use a set of numerical dynamo models to derive scaling relations between the core's characteristic dissipation time and the core's magnetic and hydrodynamic Reynolds numbers--dimensionless numbers that measure the ratio of advective transport to magnetic and viscous diffusion, respectively. The ohmic dissipation of the Karlsruhe dynamo experiment supports a simple dependence on the magnetic Reynolds number alone, indicating that flow turbulence in the experiment and in the Earth's core has little influence on its characteristic dissipation time. We use these results to predict moderate ohmic dissipation in the range of 0.2-0.5 TW, which removes the need for strong radioactive heating in the core and allows the age of the solid inner core to exceed 2.5 billion years.

  4. Vertical distribution of overpotentials and irreversible charge losses in lithium ion battery electrodes.

    PubMed

    Klink, Stefan; Schuhmann, Wolfgang; La Mantia, Fabio

    2014-08-01

    Porous lithium ion battery electrodes are characterized using a vertical distribution of cross-currents. In an appropriate simplification, this distribution can be described by a transmission line model (TLM) consisting of infinitely thin electrode layers. To investigate the vertical distribution of currents, overpotentials, and irreversible charge losses in a porous graphite electrode in situ, a multi-layered working electrode (MWE) was developed as the experimental analogue of a TLM. In this MWE, each layer is in ionic contact but electrically insulated from the other layers by a porous separator. It was found that the negative graphite electrodes get lithiated and delithiated stage-by-stage and layer-by-layer. Several mass-transport- as well as non-mass-transport-limited processes could be identified. Local current densities can reach double the average, especially on the outermost layer at the beginning of each intercalation stage. Furthermore, graphite particles close to the counter electrode act as "electrochemical sieve" reducing the impurities present in the electrolyte such as water.

  5. Suprathermal electron loss cone distributions in the solar wind: Ulysses observations

    NASA Technical Reports Server (NTRS)

    Phillips, J. L.; Feldman, W. C.; Gosling, J. T.; Hammond, C. M.; Forsyth, R. J.

    1995-01-01

    Solar wind suprathermal electron distributions in the solar wind generally carry a field-aligned antisunward heat flux. Within coronal mass ejections and upstream of strong shocks driven by corotating interaction regions (CIRs), counterstreaming electron beams are observed. We present observations by the Ulysses solar wind plasma experiment of a new class of suprathermal electron signatures. At low solar latitudes and heliocentric distances beyond 3.5 AU Ulysses encountered several intervals, ranging in duration from 1 hour to 22 hours, in which the suprathermal distributions included an antisunward field-aligned beam and a return population with a flux dropout typically spanning +/- 60 deg from the sunward field-aligned direction. All events occurred within CIRs, downstream of the forward and reverse shocks or waves bounding the interaction regions. We evaluate the hypothesis that the sunward-moving electrons result from reflection of the antisunward beams at magnetic field compressions downstream from the observations, with wide loss cones caused by the relatively weak compression ratio. This hypothesis requires that field magnitude within the CIRs actually increase with increasing field-aligned distance from the Sun. Details of the electron distributions and ramifications for CIR and shock geometry will be presented.

  6. Impact of Uncertainty on Calculations for Recovery from Loss of Offsite Power

    SciTech Connect

    Dana L. Kelly

    2010-06-01

    Uncertainty, both aleatory and epistemic, can have a significant impact on estimated probabilities of recovering from loss of offsite power within a specified time window, and such probabilities are an input to risk-informed decisions as to the significance of inspection findings in the U.S. Nuclear Regulatory Commission’s Reactor Oversight Process. In particular, the choice of aleatory model for offsite power recovery time can have a significant impact on the estimated nonrecovery probability, especially if epistemic uncertainty regarding parameters in the aleatory model is accounted for properly. In past and current analyses, such uncertainty has largely been ignored. This paper examines the impact of both aleatory and epistemic uncertainty on the results, using modern open-source Bayesian inference software, which implements Markov chain Monte Carlo sampling. It includes examples of time-dependent convolution calculations to show the impact that uncertainty can have on this increasingly frequent type of calculation, also. The results show that the “point estimate” result, which is an input to risk-informed decisions, can easily be uncertain by a factor of 10 if both aleatory and epistemic uncertainties are considered. The paper also illustrates the use of Bayesian model selection criteria to aid in the choice of aleatory model.

  7. The Role of Distributed Generation and Combined Heat and Power (CHP) Systems in Data Centers

    EPA Pesticide Factsheets

    This report reviews how distributed generation (DG) resources such as fuel cells, reciprocating engines, and gas turbines can offer powerful energy efficiency savings in data centers, particularly when configured in combined heat and power (CHP) mode.

  8. Computer Simulations of Contributions of Néel and Brown Relaxation to Specific Loss Power of Magnetic Fluids in Hyperthermia

    NASA Astrophysics Data System (ADS)

    Phong, Pham Thanh; Nguyen, Luu Huu; Manh, Do Hung; Lee, In-Ja; Phuc, Nguyen Xuan

    2017-04-01

    In this study, the degree of the contribution of particular relaxation losses to the specific loss power are calculated for a number of magnetic fluids, including Fe3O4, CoFe2O4, MnFe2O4, FeCo, FePt and La0.7Sr0.3MnO3 nanoparticles in various viscosities. We found that the specific loss of every fluid studied increases linearly with particle saturation magnetization. The competition between Néel and Brownian relaxation contributions gives rise to a peak at a critical diameter in the plot of specific loss power versus diameter. The critical diameter does not change with saturation magnetization but monotonically decreases with increasing magnetic anisotropy. If particle diameter is smaller than 6-11 nm, the maximum loss power tends to diminish and the heating effect to switch off. According to how the materials respond to viscosity change, the hyperthermia materials can be classified into two groups. One is hard nanoparticles with high anisotropy of which the critical diameter decreases with viscosity and the specific loss power versus saturation magnetization rate decreases strongly. The other is soft nanoparticles with low anisotropy of which the properties are insensitive to the viscosity of the fluid. We discuss our simulated results in relation to recent experimental findings.

  9. Power distribution in complex environmental negotiations: Does balance matter?

    USGS Publications Warehouse

    Burkardt, N.; Lamb, B.L.; Taylor, J.G.

    1997-01-01

    We studied six interagency negotiations covering Federal Energy Regulatory Commission (FERC) hydroelectric power licenses. Negotiations occurred between state and federal resource agencies and developers over project operations and natural resource mitigation. We postulated that a balance of power among parties was necessary for successful negotiations. We found a complex relationship between balanced power and success and conclude that a balance of power was associated with success in these negotiations. Power played a dynamic role in the bargaining and illuminates important considerations for regulatory design.

  10. Status of 20 kHz space station power distribution technology

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1988-01-01

    Power Distribution on the NASA Space Station will be accomplished by a 20 kHz sinusoidal, 440 VRMS, single phase system. In order to minimize both system complexity and the total power coversion steps required, high frequency power will be distributed end-to-end in the system. To support the final design of flight power system hardware, advanced development and demonstrations have been made on key system technologies and components. The current status of this program is discussed.

  11. Advanced Power Electronics Interfaces for Distributed Energy Workshop Summary: August 24, 2006, Sacramento, California

    SciTech Connect

    Treanton, B.; Palomo, J.; Kroposki, B.; Thomas, H.

    2006-10-01

    The Advanced Power Electronics Interfaces for Distributed Energy Workshop, sponsored by the California Energy Commission Public Interest Energy Research program and organized by the National Renewable Energy Laboratory, was held Aug. 24, 2006, in Sacramento, Calif. The workshop provided a forum for industry stakeholders to share their knowledge and experience about technologies, manufacturing approaches, markets, and issues in power electronics for a range of distributed energy resources. It focused on the development of advanced power electronic interfaces for distributed energy applications and included discussions of modular power electronics, component manufacturing, and power electronic applications.

  12. Suprathermal electron loss cone distributions in the solar wind: Ulysses observations

    SciTech Connect

    Phillips, J.L.; Feldman, W.C.; Gosling, J.T.; Hammond, C.M.; Forsyth, R.J.

    1995-09-01

    We present observations by the Ulysses solar wind plasma experiment of a new class of suprathermal electron signatures. At low solar latitudes and heliocentric distances beyond 3.37 AU Ulysses encountered seven intervals, ranging in duration from 1 hour to 22 hours, in which the suprathermal distributions included an antisunward field-aligned beam and a return population with a flux dropout typically spanning {plus_minus}60 ft from the sunward field-aligned direction. All events occurred between the forward and reverse shocks or waves bounding corotating interaction regions (CIRs). The observations support a scenario in which the sunward-moving electrons result from reflection of the prevailing antisunward field-aligned beam at magnetic field compressions downstream from the spacecraft, with wide loss cones caused by the relatively weak mirror ratio. This hypothesis requires that the field magnitude within the CIRs actually increased locally with increasing field-aligned distance from the Sun.

  13. Communication: Investigation of the electron momentum density distribution of nanodiamonds by electron energy-loss spectroscopy

    SciTech Connect

    Feng, Zhenbao; Yang, Bing; Lin, Yangming; Su, Dangsheng

    2015-12-07

    The electron momentum distribution of detonation nanodiamonds (DND) was investigated by recording electron energy-loss spectra at large momentum transfer in the transmission electron microscope (TEM), which is known as electron Compton scattering from solid (ECOSS). Compton profile of diamond film obtained by ECOSS was found in good agreement with prior photon experimental measurement and theoretical calculation that for bulk diamond. Compared to the diamond film, the valence Compton profile of DND was found to be narrower, which indicates a more delocalization of the ground-state charge density for the latter. Combining with other TEM characterizations such as high-resolution transmission electron spectroscopy, diffraction, and energy dispersive X-ray spectroscopy measurements, ECOSS was shown to be a great potential technique to study ground-state electronic properties of nanomaterials.

  14. Fiber-distributed Ultra-wideband noise radar with steerable power spectrum and colorless base station.

    PubMed

    Zheng, Jianyu; Wang, Hui; Fu, Jianbin; Wei, Li; Pan, Shilong; Wang, Lixian; Liu, Jianguo; Zhu, Ninghua

    2014-03-10

    A fiber-distributed Ultra-wideband (UWB) noise radar was achieved, which consists of a chaotic UWB noise source based on optoelectronic oscillator (OEO), a fiber-distributed transmission link, a colorless base station (BS), and a cross-correlation processing module. Due to a polarization modulation based microwave photonic filter and an electrical UWB pass-band filter embedded in the feedback loop of the OEO, the power spectrum of chaotic UWB signal could be shaped and notch-filtered to avoid the spectrum-overlay-induced interference to the narrow band signals. Meanwhile, the wavelength-reusing could be implemented in the BS by means of the distributed polarization modulation-to-intensity modulation conversion. The experimental comparison for range finding was carried out as the chaotic UWB signal was notch-filtered at 5.2 GHz and 7.8 GHz or not. Measured results indicate that space resolution with cm-level could be realized after 3-km fiber transmission thanks to the excellent self-correlation property of the UWB noise signal provided by the OEO. The performance deterioration of the radar raised by the energy loss of the notch-filtered noise signal was negligible.

  15. Optimal operation management of fuel cell/wind/photovoltaic power sources connected to distribution networks

    NASA Astrophysics Data System (ADS)

    Niknam, Taher; Kavousifard, Abdollah; Tabatabaei, Sajad; Aghaei, Jamshid

    2011-10-01

    In this paper a new multiobjective modified honey bee mating optimization (MHBMO) algorithm is presented to investigate the distribution feeder reconfiguration (DFR) problem considering renewable energy sources (RESs) (photovoltaics, fuel cell and wind energy) connected to the distribution network. The objective functions of the problem to be minimized are the electrical active power losses, the voltage deviations, the total electrical energy costs and the total emissions of RESs and substations. During the optimization process, the proposed algorithm finds a set of non-dominated (Pareto) optimal solutions which are stored in an external memory called repository. Since the objective functions investigated are not the same, a fuzzy clustering algorithm is utilized to handle the size of the repository in the specified limits. Moreover, a fuzzy-based decision maker is adopted to select the 'best' compromised solution among the non-dominated optimal solutions of multiobjective optimization problem. In order to see the feasibility and effectiveness of the proposed algorithm, two standard distribution test systems are used as case studies.

  16. Proposal for Wireless Power Distribution System with Capacitive Coupling Using One-Pulse Switching Active Capacitor

    NASA Astrophysics Data System (ADS)

    Funato, Hirohito; Chiku, Yuki; Harakawa, Ken-Ichi

    Wireless electric power distribution is an attractive means of supplying power to mobile equipment such as mobile phones and electric vehicles. Magnetic field coupling is the most popular method for wireless power distribution. However, this method has certain disadvantages such as power decrease in the case of inexact placement of couplings. Wireless power distribution with capacitive coupling has been proposed to overcome the disadvantages of wireless power distribution with magnetic field coupling. It is, however, difficult to transfer high power owing to the small capacitance of capacitive coupling. The authors propose a new power converter suitable for wireless power distribution with capacitive coupling using a novel one-pulse switching active capacitor (OPSAC) to enhance power transfer. The proposed system improves the power transfer efficiency without LC resonance and is hence robust to parameter change. In this paper, a wireless power distribution system with improved OPSAC (I-OPSAC) is proposed. In the I-OPSAC, the dc voltage source for the inverter is replaced by a capacitor because the OPSAC behaves like a reactive element. The I-OPSAC shows stable operation without any feedback loop including dc capacitor voltage control. In this paper, a control scheme and the detailed operational characteristics are reported, in addition to the simulations and experimental results.

  17. Three dimensional numerical prediction of icing related power and energy losses on a wind turbine

    NASA Astrophysics Data System (ADS)

    Sagol, Ece

    Regions of Canada experience harsh winter conditions that may persist for several months. Consequently, wind turbines located in these regions are exposed to ice accretion and its adverse effects, from loss of power to ceasing to function altogether. Since the weather-related annual energy production loss of a turbine may be as high as 16% of the nominal production for Canada, estimating these losses before the construction of a wind farm is essential for investors. A literature survey shows that most icing prediction methods and codes are developed for aircraft, and, as this information is mostly considered corporate intellectual property, it is not accessible to researchers in other domains. Moreover, aircraft icing is quite different from wind turbine icing. Wind turbines are exposed to icing conditions for much longer periods than aircraft, perhaps for several days in a harsh climate, whereas the maximum length of exposure of an aircraft is about 3-4 hours. In addition, wind turbine blades operate at subsonic speeds, at lower Reynolds numbers than aircraft, and their physical characteristics are different. A few icing codes have been developed for wind turbine icing nevertheless. However, they are either in 2D, which does not consider the 3D characteristics of the flow field, or they focus on simulating each rotation in a time-dependent manner, which is not practical for computing long hours of ice accretion. Our objective in this thesis is to develop a 3D numerical methodology to predict rime ice shape and the power loss of a wind turbine as a function of wind farm icing conditions. In addition, we compute the Annual Energy Production of a sample turbine under both clean and icing conditions. The sample turbine we have selected is the NREL Phase VI experimental wind turbine installed on a wind farm in Sweden, the icing events at which have been recorded and published. The proposed method is based on computing and validating the clean performance of the turbine

  18. Heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter

    NASA Astrophysics Data System (ADS)

    Sung, Hae-Jin; Go, Byeong-Soo; Jiang, Zhenan; Park, Minwon; Yu, In-Keun

    2016-11-01

    The development of an effective high-temperature superconducting (HTS) generator is currently a research focus; however, the reduction of heat loss of a large-scale HTS generator is a challenge. This study deals with a heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter. The generator module consists of an HTS rotor of the generator and an HTS flux pump exciter. The specifications of the module were described, and the detailed configuration of the module was illustrated. For the heat loss analysis of the module, the excitation loss of the flux pump exciter, eddy current loss of all of the structures in the module, radiation loss, and conduction loss of an HTS coil supporter were assessed using a 3D finite elements method program. In the case of the conduction loss, different types of the supporters were compared to find out the supporter of the lowest conduction loss in the module. The heat loss analysis results of the module were reflected in the design of the generator module and discussed in detail. The results will be applied to the design of large-scale superconducting generators for wind turbines including a cooling system.

  19. Heat loss distribution: Impedance and thermal loss analyses in LiFePO4/graphite 18650 electrochemical cell

    NASA Astrophysics Data System (ADS)

    Balasundaram, Manikandan; Ramar, Vishwanathan; Yap, Christopher; Lu, Li; Tay, Andrew A. O.; Palani, Balaya

    2016-10-01

    We report here thermal behaviour and various components of heat loss of 18650-type LiFePO4/graphite cell at different testing conditions. In this regard, the total heat generated during charging and discharging processes at various current rates (C) has been quantified in an Accelerating Rate Calorimeter experiment. Irreversible heat generation, which depends on applied current and internal cell resistance, is measured under corresponding charge/discharge conditions using intermittent pulse techniques. On the other hand, reversible heat generation which depends on entropy changes of the electrode materials during the cell reaction is measured from the determination of entropic coefficient at various states of charge/discharge. The contributions of irreversible and reversible heat generation to the total heat generation at both high and low current rates are evaluated. At every state of charge/discharge, the nature of the cell reaction is found to be either exothermic or endothermic which is especially evident at low C rates. In addition, electrochemical impedance spectroscopy measurements are performed on above 18650 cells at various states of charge to determine the components of internal resistance. The findings from the impedance and thermal loss analysis are helpful for understanding the favourable states of charge/discharge for battery operation, and designing better thermal management systems.

  20. Vertical distribution of dry mass in cereals straw and its loss during harvesting

    NASA Astrophysics Data System (ADS)

    Zajaç, T.; Oleksy, A.; Stokłosa, A.; Klimek-Kopyra, A.; Macuda, J.

    2013-01-01

    The study aimed at evaluating the distribution of mass in the straw of cereal species and also at assessing the straw yield and its losses resulting from the amount of the stubble left in the field. It was found empirically that the wheat culms are composed of five internodes, and in barley, triticale and oats of six. The highest straw mass per 1 cm was found in the second internode in both forms of wheat and winter triticale, whereas barley and oats gathered the highest weight in the first internode. In the southern part of Silesia species and forms of cereals differed in the straw yield, which can be arranged as follows, from the highest: winter wheat > spring wheat, winter triticale, winter barley, and oats > spring barley. Due to the specific distribution of dry matter in each of internodes of both wheat forms - winter and spring, they loose less stubble mass (22 and 24%, respectively), comparing to other cereals, especially spring barley, which loose 31% yield of straw in the stubble of 15 cm height.

  1. High voltage-high power components for large space power distribution systems

    NASA Technical Reports Server (NTRS)

    Renz, D. D.

    1984-01-01

    Space power components including a family of bipolar power switching transistors, fast switching power diodes, heat pipe cooled high frequency transformers and inductors, high frequency conduction cooled transformers, high power-high frequency capacitors, remote power controllers and rotary power transfer devices were developed. Many of these components such as the power switching transistors, power diodes and the high frequency capacitor are commercially available. All the other components were developed to the prototype level. The dc/dc series resonant converters were built to the 25 kW level.

  2. Computer Calculations of Eddy-Current Power Loss in Rotating Titanium Wheels and Rims in Localized Axial Magnetic Fields

    SciTech Connect

    Mayhall, D J; Stein, W; Gronberg, J B

    2006-05-15

    We have performed preliminary computer-based, transient, magnetostatic calculations of the eddy-current power loss in rotating titanium-alloy and aluminum wheels and wheel rims in the predominantly axially-directed, steady magnetic fields of two small, solenoidal coils. These calculations have been undertaken to assess the eddy-current power loss in various possible International Linear Collider (ILC) positron target wheels. They have also been done to validate the simulation code module against known results published in the literature. The commercially available software package used in these calculations is the Maxwell 3D, Version 10, Transient Module from the Ansoft Corporation.

  3. Power tails of index distributions in chinese stock market

    NASA Astrophysics Data System (ADS)

    Zhang, J. W.; Zhang, Y.; Kleinert, H.

    2007-04-01

    The power α of the Lévy tails of stock market fluctuations discovered in recent years are generally believed to be universal. We show that for the Chinese stock market this is not true, the powers depending strongly on anomalous daily index changes short before market closure, and weakly on the opening data.

  4. Distributed Energy Resources, Power Quality and Reliability - Background

    SciTech Connect

    Schienbein, Lawrence A.; DeSteese, John G.

    2002-01-31

    Power quality [PQ] and power reliability [PR] gained importance in the industrialized world as the pace of installation of sensitive appliances and other electrical loads by utility customers accelerated, beginning in the mid 1980s. Utility-grid-connected customers rapidly discovered that this equipment was increasingly sensitive to various abnormalities in the electricity supply.

  5. Ammonia thermochemical energy transport in a distributed collector solar thermal power plant

    NASA Astrophysics Data System (ADS)

    Williams, O. M.

    1981-01-01

    A thermochemical energy transport system based on ammonia dissociation/synthesis is shown to have potential for reliable cost-effective operation in a distributed collector solar thermal power plant. Liquid ammonia returned to the central plant from a shaded absorber remains inherently separated from the synthesis gas mixture returned from an exposed absorber, enabling the maintenance of a centralized fluid control. Temporal characteristics of the ammonia-based solar thermochemical absorbers are developed by numerical analysis. Sources of energy loss are examined, and it is shown that flow rates to individual absorbers may cover a 12% range of variation without degradation to the overall energy transport efficiency. Operation of the absorber array is examined under conditions of extreme insolation variation due to a scattered cloud cover. The importance of minimizing the absorber thermal capacity is discussed in relation to the available energy required to restore operation after each cloud period. It is shown that the system is relatively immune to large energy losses in this area, compared to the alternative system where both the pipelines and absorbers must be reheated.

  6. Improving Power Quality in Low-Voltage Networks Containing Distributed Energy Resources

    NASA Astrophysics Data System (ADS)

    Mazumder, Sumit; Ghosh, Arindam; Zare, Firuz

    2013-05-01

    Severe power quality problems can arise when a large number of single-phase distributed energy resources (DERs) are connected to a low-voltage power distribution system. Due to the random location and size of DERs, it may so happen that a particular phase generates excess power than its load demand. In such an event, the excess power will be fed back to the distribution substation and will eventually find its way to the transmission network, causing undesirable voltage-current unbalance. As a solution to this problem, the article proposes the use of a distribution static compensator (DSTATCOM), which regulates voltage at the point of common coupling (PCC), thereby ensuring balanced current flow from and to the distribution substation. Additionally, this device can also support the distribution network in the absence of the utility connection, making the distribution system work as a microgrid. The proposals are validated through extensive digital computer simulation studies using PSCADTM.

  7. Assessment of hindlimb gait as a powerful indicator of axonal loss in a murine model of progressive CNS demyelination

    PubMed Central

    McGavern, Dorian B.; Zoecklein, Laurie; Sathornsumetee, Sith; Rodriguez, Moses

    2017-01-01

    Identifying the role of axonal injury in the development of permanent, irreversible neurologic disability is important to the study of central nervous system (CNS) demyelinating diseases. Our understanding of neurologic dysfunction in demyelinating diseases and the ability to assess therapeutic interventions depends on the development of objective functional assays that can non-invasively measure axonal loss. In this study, we demonstrate in a murine model of progressive CNS demyelination that assessment of the hindlimb width of stride provides a powerful indicator of axonal loss and can dissociate between deficits induced by demyelination versus axonal loss. PMID:10986359

  8. Design of low-loss 1-3 piezoelectric composites for high-power transducer applications.

    PubMed

    Lee, Hyeong Jae; Zhang, Shujun

    2012-09-01

    Lead zirconate titanate (PZT)/polymer 1-3 composites have improved electromechanical properties compared with monolithic counterparts, but possess a low mechanical quality factor, limiting their use in high-power transducer applications. The goal of this work was to improve the mechanical quality factor of 1-3 PZT/polymer composites by optimizing the polymer materials. Theoretical analysis and modeling were performed for optimum composite design and various polymers were prepared and characterized. 1-3 piezocomposites were constructed and their electromechanical properties were experimentally determined. The results demonstrated that the composites with high-thermal-conductivity polymers generally have degraded electromechanical properties with significantly decreased mechanical quality factors, whereas the composites filled with low-loss and low-moduli polymers were found to have higher mechanical quality factors with higher electromechanical coupling factors: Q(m) ~ 200 and k(t) ~ 0.68 for PZT4 composites; Q(m) ~ 400 and k(t) ~ 0.6 for PZT8 composites. The improved mechanical quality factor of 1-3 piezocomposites may offer improved performance and thermal stability of transducers under high-drive operation.

  9. Design of Low-Loss 1–3 Piezoelectric Composites for High-Power Transducer Applications

    PubMed Central

    Lee, Hyeong Jae; Zhang, Shujun

    2013-01-01

    Lead zirconate titanate (PZT)/polymer 1–3 composites have improved electromechanical properties compared with monolithic counterparts, but possess a low mechanical quality factor, limiting their use in high-power transducer applications. The goal of this work was to improve the mechanical quality factor of 1–3 PZT/polymer composites by optimizing the polymer materials. Theoretical analysis and modeling were performed for optimum composite design and various polymers were prepared and characterized. 1–3 piezocomposites were constructed and their electromechanical properties were experimentally determined. The results demonstrated that the composites with high-thermal-conductivity polymers generally have degraded electromechanical properties with significantly decreased mechanical quality factors, whereas the composites filled with low-loss and low-moduli polymers were found to have higher mechanical quality factors with higher electrome-chanical coupling factors: Qm ~ 200 and kt ~ 0.68 for PZT4 composites; Qm ~ 400 and kt ~ 0.6 for PZT8 composites. The improved mechanical quality factor of 1–3 piezocomposites may offer improved performance and thermal stability of transducers under high-drive operation. PMID:23007769

  10. Systems analysis of the space shuttle. [communication systems, computer systems, and power distribution

    NASA Technical Reports Server (NTRS)

    Schilling, D. L.; Oh, S. J.; Thau, F.

    1975-01-01

    Developments in communications systems, computer systems, and power distribution systems for the space shuttle are described. The use of high speed delta modulation for bit rate compression in the transmission of television signals is discussed. Simultaneous Multiprocessor Organization, an approach to computer organization, is presented. Methods of computer simulation and automatic malfunction detection for the shuttle power distribution system are also described.

  11. Megawatt Space Power Conditioning, Distribution, and Control Study

    DTIC Science & Technology

    1988-03-01

    2.4.1 Reactor Transmision Interface 16 2.4.2 Transmission Converter Interface 16 2.4.3 Klystrode Accelerator Interface 16 2.5 Summary and Development...iii CONTENTS (Continued) Page 3.2 Power Sources 43 3.2.1 Prime Power 43 3.2.2 Rotating Machines 47 3.2.2.1 Alternators 47 3.2.3 Static Power...they can be categorized as follows: 2.2.1 Alternating Current (ac) Devices. These are all turbine- generator machines , which can be driven by any

  12. Development of An On-Line, Core Power Distribution Monitoring System

    SciTech Connect

    Tunc ALdemir; Don Miller; Peng Wang

    2007-10-02

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  13. Advanced distribution, switching, and conversion technology for fluids/combustion facility electric power control

    NASA Astrophysics Data System (ADS)

    Poljak, Mark D.; Soltis, James V.; Fox, David A.

    1997-01-01

    The Electrical Power Control Unit (EPCU) under development for use in the Fluids/Combustion Facility (FCF) on International Space Station (ISS) is the precursor of modular power distribution and conversion concepts for future high power and small spacecraft applications. The EPCU is built from modular, current limiting Flexible Remote Power Controllers (FRPCs) and paralleled power converters packaged into a common orbital replacement unit. Multiple EPCUs are combined at the next higher level of integration to form the three-rack FCF Electrical Power System (EPS). This modular building block approach allows for the quick development of expandable power systems tailored to customer needs.

  14. A majorization-minimization approach to design of power distribution networks

    SciTech Connect

    Johnson, Jason K; Chertkov, Michael

    2010-01-01

    We consider optimization approaches to design cost-effective electrical networks for power distribution. This involves a trade-off between minimizing the power loss due to resistive heating of the lines and minimizing the construction cost (modeled by a linear cost in the number of lines plus a linear cost on the conductance of each line). We begin with a convex optimization method based on the paper 'Minimizing Effective Resistance of a Graph' [Ghosh, Boyd & Saberi]. However, this does not address the Alternating Current (AC) realm and the combinatorial aspect of adding/removing lines of the network. Hence, we consider a non-convex continuation method that imposes a concave cost of the conductance of each line thereby favoring sparser solutions. By varying a parameter of this penalty we extrapolate from the convex problem (with non-sparse solutions) to the combinatorial problem (with sparse solutions). This is used as a heuristic to find good solutions (local minima) of the non-convex problem. To perform the necessary non-convex optimization steps, we use the majorization-minimization algorithm that performs a sequence of convex optimizations obtained by iteratively linearizing the concave part of the objective. A number of examples are presented which suggest that the overall method is a good heuristic for network design. We also consider how to obtain sparse networks that are still robust against failures of lines and/or generators.

  15. Self-Powered WSN for Distributed Data Center Monitoring.

    PubMed

    Brunelli, Davide; Passerone, Roberto; Rizzon, Luca; Rossi, Maurizio; Sartori, Davide

    2016-01-02

    Monitoring environmental parameters in data centers is gathering nowadays increasing attention from industry, due to the need of high energy efficiency of cloud services. We present the design and the characterization of an energy neutral embedded wireless system, prototyped to monitor perpetually environmental parameters in servers and racks. It is powered by an energy harvesting module based on Thermoelectric Generators, which converts the heat dissipation from the servers. Starting from the empirical characterization of the energy harvester, we present a power conditioning circuit optimized for the specific application. The whole system has been enhanced with several sensors. An ultra-low-power micro-controller stacked over the energy harvesting provides an efficient power management. Performance have been assessed and compared with the analytical model for validation.

  16. Electric Power Generation, Transmission and Distribution (NAICS 2211)

    EPA Pesticide Factsheets

    Find EPA regulatory information for electrical utilities, including coal-fired power plants. Includes links to NESHAPs for RICE, stationary combustion engines, fossil fuel waste, cooling water, effluent guidelines. Find information on the MATS rule.

  17. Space power distribution system technology. Volume 3: Test facility design

    NASA Technical Reports Server (NTRS)

    Decker, D. K.; Cannady, M. D.; Cassinelli, J. E.; Farber, B. F.; Lurie, C.; Fleck, G. W.; Lepisto, J. W.; Messner, A.; Ritterman, P. F.

    1983-01-01

    The AMPS test facility is a major tool in the attainment of more economical space power. The ultimate goals of the test facility, its primary functional requirements and conceptual design, and the major equipment it contains are discussed.

  18. Self-Powered WSN for Distributed Data Center Monitoring

    PubMed Central

    Brunelli, Davide; Passerone, Roberto; Rizzon, Luca; Rossi, Maurizio; Sartori, Davide

    2016-01-01

    Monitoring environmental parameters in data centers is gathering nowadays increasing attention from industry, due to the need of high energy efficiency of cloud services. We present the design and the characterization of an energy neutral embedded wireless system, prototyped to monitor perpetually environmental parameters in servers and racks. It is powered by an energy harvesting module based on Thermoelectric Generators, which converts the heat dissipation from the servers. Starting from the empirical characterization of the energy harvester, we present a power conditioning circuit optimized for the specific application. The whole system has been enhanced with several sensors. An ultra-low-power micro-controller stacked over the energy harvesting provides an efficient power management. Performance have been assessed and compared with the analytical model for validation. PMID:26729135

  19. Spatial and temporal distribution of mass loss from the Greenland Ice Sheet since AD 1900.

    PubMed

    Kjeldsen, Kristian K; Korsgaard, Niels J; Bjørk, Anders A; Khan, Shfaqat A; Box, Jason E; Funder, Svend; Larsen, Nicolaj K; Bamber, Jonathan L; Colgan, William; van den Broeke, Michiel; Siggaard-Andersen, Marie-Louise; Nuth, Christopher; Schomacker, Anders; Andresen, Camilla S; Willerslev, Eske; Kjær, Kurt H

    2015-12-17

    The response of the Greenland Ice Sheet (GIS) to changes in temperature during the twentieth century remains contentious, largely owing to difficulties in estimating the spatial and temporal distribution of ice mass changes before 1992, when Greenland-wide observations first became available. The only previous estimates of change during the twentieth century are based on empirical modelling and energy balance modelling. Consequently, no observation-based estimates of the contribution from the GIS to the global-mean sea level budget before 1990 are included in the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. Here we calculate spatial ice mass loss around the entire GIS from 1900 to the present using aerial imagery from the 1980s. This allows accurate high-resolution mapping of geomorphic features related to the maximum extent of the GIS during the Little Ice Age at the end of the nineteenth century. We estimate the total ice mass loss and its spatial distribution for three periods: 1900-1983 (75.1 ± 29.4 gigatonnes per year), 1983-2003 (73.8 ± 40.5 gigatonnes per year), and 2003-2010 (186.4 ± 18.9 gigatonnes per year). Furthermore, using two surface mass balance models we partition the mass balance into a term for surface mass balance (that is, total precipitation minus total sublimation minus runoff) and a dynamic term. We find that many areas currently undergoing change are identical to those that experienced considerable thinning throughout the twentieth century. We also reveal that the surface mass balance term shows a considerable decrease since 2003, whereas the dynamic term is constant over the past 110 years. Overall, our observation-based findings show that during the twentieth century the GIS contributed at least 25.0 ± 9.4 millimetres of global-mean sea level rise. Our result will help to close the twentieth-century sea level budget, which remains crucial for evaluating the reliability of models used to

  20. Spatial and temporal distribution of mass loss from the Greenland Ice Sheet since AD 1900

    NASA Astrophysics Data System (ADS)

    Kjeldsen, Kristian K.; Korsgaard, Niels J.; Bjørk, Anders A.; Khan, Shfaqat A.; Box, Jason E.; Funder, Svend; Larsen, Nicolaj K.; Bamber, Jonathan L.; Colgan, William; van den Broeke, Michiel; Siggaard-Andersen, Marie-Louise; Nuth, Christopher; Schomacker, Anders; Andresen, Camilla S.; Willerslev, Eske; Kjær, Kurt H.

    2015-12-01

    The response of the Greenland Ice Sheet (GIS) to changes in temperature during the twentieth century remains contentious, largely owing to difficulties in estimating the spatial and temporal distribution of ice mass changes before 1992, when Greenland-wide observations first became available. The only previous estimates of change during the twentieth century are based on empirical modelling and energy balance modelling. Consequently, no observation-based estimates of the contribution from the GIS to the global-mean sea level budget before 1990 are included in the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. Here we calculate spatial ice mass loss around the entire GIS from 1900 to the present using aerial imagery from the 1980s. This allows accurate high-resolution mapping of geomorphic features related to the maximum extent of the GIS during the Little Ice Age at the end of the nineteenth century. We estimate the total ice mass loss and its spatial distribution for three periods: 1900-1983 (75.1 ± 29.4 gigatonnes per year), 1983-2003 (73.8 ± 40.5 gigatonnes per year), and 2003-2010 (186.4 ± 18.9 gigatonnes per year). Furthermore, using two surface mass balance models we partition the mass balance into a term for surface mass balance (that is, total precipitation minus total sublimation minus runoff) and a dynamic term. We find that many areas currently undergoing change are identical to those that experienced considerable thinning throughout the twentieth century. We also reveal that the surface mass balance term shows a considerable decrease since 2003, whereas the dynamic term is constant over the past 110 years. Overall, our observation-based findings show that during the twentieth century the GIS contributed at least 25.0 ± 9.4 millimetres of global-mean sea level rise. Our result will help to close the twentieth-century sea level budget, which remains crucial for evaluating the reliability of models used to

  1. AC/DC Smart Control And Power Sharing of DC Distribution Systems

    DTIC Science & Technology

    2012-02-10

    Thesis submitted in partial requirement for the degree of MASTER OF SCIENCE in ELECTRICAL ENGINEERING by Mohamed Anwar Elshaer 2012...will play vital role in electric power systems. It allows residents and businesses the potential to generate electrical energy to sell surplus power...better method for electrical power delivery. This concept is inspired by the possibility of efficient integration of small distributed generation

  2. A High Power Density DC-DC Converter for Distributed PV Architectures

    SciTech Connect

    Agamy, Mohammed S; Chi, Song; Elasser, Ahmed; Harfman-Todorovic, Maja; Jiang, Yan; Mueller, Frank; Tao, Fengfeng

    2012-06-01

    In order to maximize solar energy harvesting capabilities, power converters have to be designed for high efficiency and good MPPT and voltage/current performance. When many converters are used in distributed systems, power density also becomes an important factor as it allows for simpler system integration. In this paper a high power density string dc-dc converter suitable for distributed medium to large scale PV installation is presented. A simple partial power processing topology, implemented with all silicon carbide devices provides high efficiency as well as high power density. A 3.5kW, 100kHz converter is designed and tested to verify the proposed methods.

  3. Electromagnetic and thermal analysis of distributed cooled high power millimeter wave windows

    SciTech Connect

    Nelson, S.D.; Reitter, T.; Caplan, M.

    1995-05-12

    The sectional high-frequency internally-cooled window, as proposed by General Atomics, has unique potential for allowing microwave sources to reach multi-megawatt CW levels with application to ECRH. Designs are being investigated using computational electromagnetic (EM), thermal, and mechanical codes at 110 GHz and 170 GHz to examine the design tradeoffs between RF performance and thermal mechanical safety margins. The EM analyses are for the window, under vacuum at one MW and includes variations in the shapes of the cooling fins, the surface treatment of the window elements themselves, the cooling fin tip treatment, the window pitch angle, and the waveguide effects. One advantage of the distributed cooled window is it`s extensibility to higher power levels. Results in the modeling efforts are presented showing the EM field concentrations (which then will feed into the thermal analysis), the energy scattering/reflection, the transmitted launch angle variation as a function of physical geometry, and the spatial energy distribution and loss as a function of time and position.

  4. Comparison of Calculated and Experimental Total-Pressure Loss and Airflow Distribution in Tubular Turbojet Combustors with Tapered Liners

    NASA Technical Reports Server (NTRS)

    Grobman, Jack S.

    1959-01-01

    Incompressible-flow calculations were performed to determine the effects of combustor geometric and operating variables on pressure loss and airflow distribution in a tubular combustor with a tapered liner. The calculations include the effects of momentum transfer between annulus and liner gas streams, annulus wall friction, heat release, and discharge coefficients of liner air-entry holes. Generalized curves are presented which show the effects of liner-wall inclination, liner open hole area, and temperature rise across the combustor on pressure loss and airflow distribution for a representative parabolic liner hole distribution. A comparison of the experimental data from 12 tapered liners with the theoretical calculations indicates that reasonable design estimates can be made from the generalized curves. The calculated pressure losses of the tapered liners are compared with those previously reported for tubular liners.

  5. Impacts of propagating, frustrated and surface modes on radiative, electrical and thermal losses in nanoscale-gap thermophotovoltaic power generators.

    PubMed

    Bernardi, Michael P; Dupré, Olivier; Blandre, Etienne; Chapuis, Pierre-Olivier; Vaillon, Rodolphe; Francoeur, Mathieu

    2015-06-26

    The impacts of radiative, electrical and thermal losses on the performances of nanoscale-gap thermophotovoltaic (nano-TPV) power generators consisting of a gallium antimonide cell paired with a broadband tungsten and a radiatively-optimized Drude radiator are analyzed. Results reveal that surface mode mediated nano-TPV power generation with the Drude radiator outperforms the tungsten radiator, dominated by frustrated modes, only for a vacuum gap thickness of 10 nm and if both electrical and thermal losses are neglected. The key limiting factors for the Drude- and tungsten-based devices are respectively the recombination of electron-hole pairs at the cell surface and thermalization of radiation with energy larger than the cell absorption bandgap. A design guideline is also proposed where a high energy cutoff above which radiation has a net negative effect on nano-TPV power output due to thermal losses is determined. It is shown that the power output of a tungsten-based device increases by 6.5% while the cell temperature decreases by 30 K when applying a high energy cutoff at 1.45 eV. This work demonstrates that design and optimization of nano-TPV devices must account for radiative, electrical and thermal losses.

  6. Impacts of propagating, frustrated and surface modes on radiative, electrical and thermal losses in nanoscale-gap thermophotovoltaic power generators

    PubMed Central

    Bernardi, Michael P.; Dupré, Olivier; Blandre, Etienne; Chapuis, Pierre-Olivier; Vaillon, Rodolphe; Francoeur, Mathieu

    2015-01-01

    The impacts of radiative, electrical and thermal losses on the performances of nanoscale-gap thermophotovoltaic (nano-TPV) power generators consisting of a gallium antimonide cell paired with a broadband tungsten and a radiatively-optimized Drude radiator are analyzed. Results reveal that surface mode mediated nano-TPV power generation with the Drude radiator outperforms the tungsten radiator, dominated by frustrated modes, only for a vacuum gap thickness of 10 nm and if both electrical and thermal losses are neglected. The key limiting factors for the Drude- and tungsten-based devices are respectively the recombination of electron-hole pairs at the cell surface and thermalization of radiation with energy larger than the cell absorption bandgap. A design guideline is also proposed where a high energy cutoff above which radiation has a net negative effect on nano-TPV power output due to thermal losses is determined. It is shown that the power output of a tungsten-based device increases by 6.5% while the cell temperature decreases by 30 K when applying a high energy cutoff at 1.45 eV. This work demonstrates that design and optimization of nano-TPV devices must account for radiative, electrical and thermal losses. PMID:26112658

  7. Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses

    PubMed Central

    Papadatou, Eleni; Del Águila-Carrasco, Antonio J.; Esteve-Taboada, José J.; Madrid-Costa, David; Cerviño-Expósito, Alejandro

    2017-01-01

    AIM To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. METHODS Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. RESULTS The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about −3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens. CONCLUSION In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient's visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome. PMID:28149785

  8. A Preliminary Analysis of the Economics of Using Distributed Energy as a Source of Reactive Power Supply

    SciTech Connect

    Li, Fangxing; Kueck, John D; Rizy, D Tom; King, Thomas F

    2006-04-01

    the best way to allocate the benefit among customers, utilities, transmission companies or RTOs. With the hidden benefits discovered, it will be easier for the policy maker to re-assess the value of reactive power and to form a sound competitive market for this service. Along with the capability of DE to provide local reactive power, a market needs to exist to promote the operation of DE to regulate voltage and net power factor. There are a number of potential benefits that have been identified including capacity relief, loss reduction, improved system reliability, extended equipment life, reduced transport of reactive power from the G&T, and improved local voltage regulation and power factor. An attempt has been made using very simple data and cases to quantify these benefits. Only the model of a larger and more detailed distribution system with DE can truly give a full picture of the benefits that reactive power from local DE can provide.

  9. Simulation of a Lunar Surface Base Power Distribution Network for the Constellation Lunar Surface Systems

    NASA Technical Reports Server (NTRS)

    Mintz, Toby; Maslowski, Edward A.; Colozza, Anthony; McFarland, Willard; Prokopius, Kevin P.; George, Patrick J.; Hussey, Sam W.

    2010-01-01

    The Lunar Surface Power Distribution Network Study team worked to define, breadboard, build and test an electrical power distribution system consistent with NASA's goal of providing electrical power to sustain life and power equipment used to explore the lunar surface. A testbed was set up to simulate the connection of different power sources and loads together to form a mini-grid and gain an understanding of how the power systems would interact. Within the power distribution scheme, each power source contributes to the grid in an independent manner without communication among the power sources and without a master-slave scenario. The grid consisted of four separate power sources and the accompanying power conditioning equipment. Overall system design and testing was performed. The tests were performed to observe the output and interaction of the different power sources as some sources are added and others are removed from the grid connection. The loads on the system were also varied from no load to maximum load to observe the power source interactions.

  10. Comment on "probability distribution of power fluctuations in turbulence".

    PubMed

    Nadarajah, Saralees; Ongodiebi, Zuonaki

    2014-06-01

    Bandi et al. [Phys. Rev. E 79, 016309 (2009)] reported a closed form expression for the probability density function of the product of two correlated normal random variables and proposed an approximation for the distribution of its mean. Here, we question the closed form expression and derive exact expressions for the distribution of the mean. The proposed approximation is shown to be poor.

  11. A novel fault diagnosis method of PV based-on power loss and I-V characteristics

    NASA Astrophysics Data System (ADS)

    Chen, Y. H.; Liang, R.; Tian, Y.; Wang, F.

    2016-08-01

    The power loss and the changes of internal I-V output characteristics of photovoltaic (PV) module in the typical fault condition were analyzed. We proposed an on-line real time fault diagnosis method for PV module, which takes into account the power loss and the internal I-V characteristics. Taking into account the changes of temperature and irradiation, the running status of the PV module were simulated in real time. Firstly, by comparing the simulated power with the measured power, it could determine whether the abnormal power loss has occurred. Then based on the change of output voltage, it could decide if short-circuit fault has occurred and estimate the number of short circuited cells roughly. Further, the value of fill factor (FF) can be utilized to determine whether aging fault has occurred and to acquire the remaining service life of the module. The results of simulation and experiment show that this method can effectively detect the partial shadow short-circuit fault and aging fault. It proves the feasibility and accuracy of the fault diagnosis method.

  12. Transformer failure and common-mode loss of instrument power at Nine Mile Point Unit 2 on August 13, 1991

    SciTech Connect

    Not Available

    1991-10-01

    On August 13, 1991, at Nine Mile Point Unit 2 nuclear power plant, located near Scriba, New York, on Lake Ontario, the main transformer experienced an internal failure that resulted in degraded voltage which caused the simultaneous loss of five uninterruptible power supplies, which in turn caused the loss of several nonsafety systems, including reactor control rod position indication, some reactor power and water indication, control room annunciators, the plant communications system, the plant process computer, and lighting at some locations. The reactor was subsequently brought to a safe shutdown. Following this event, the US Nuclear Regulatory Commission dispatched an Incident Investigation Team to the site to determine what happened, to identify the probable causes, and to make appropriate findings and conclusions. This report describes the incident, the methodology used by the team in its investigation, and presents and the team's findings and conclusions. 59 figs., 14 tabs.

  13. Distributed Control of Inverter-Based Lossy Microgrids for Power Sharing and Frequency Regulation Under Voltage Constraints

    SciTech Connect

    Chang, Chin-Yao; Zhang, Wei

    2016-01-19

    This paper presents a new distributed control framework to coordinate inverter-interfaced distributed energy resources (DERs) in island microgrids. We show that under bounded load uncertainties, the proposed control method can steer the microgrid to a desired steady state with synchronized inverter frequency across the network and proportional sharing of both active and reactive powers among the inverters. We also show that such convergence can be achieved while respecting constraints on voltage magnitude and branch angle differences. The controller is robust under various contingency scenarios, including loss of communication links and failures of DERs. The proposed controller is applicable to lossy mesh microgrids with heterogeneous R/X distribution lines and reasonable parameter variations. Simulations based on various microgrid operation scenarios are also provided to show the effectiveness of the proposed control method.

  14. Microgrids, virtual power plants and our distributed energy future

    SciTech Connect

    Asmus, Peter

    2010-12-15

    Opportunities for VPPs and microgrids will only increase dramatically with time, as the traditional system of building larger and larger centralized and polluting power plants by utilities charging a regulated rate of return fades. The key questions are: how soon will these new business models thrive - and who will be in the driver's seat? (author)

  15. Protecting Intelligent Distributed Power Grids against Cyber Attacks

    SciTech Connect

    Dong Wei; Yan Lu; Mohsen Jafari; Paul Skare; Kenneth Rohde

    2010-12-31

    Like other industrial sectors, the electrical power industry is facing challenges involved with the increasing demand for interconnected operations and control. The electrical industry has largely been restructured due to deregulation of the electrical market and the trend of the Smart Grid. This moves new automation systems from being proprietary and closed to the current state of Information Technology (IT) being highly interconnected and open. However, while gaining all of the scale and performance benefits of IT, existing IT security challenges are acquired as well. The power grid automation network has inherent security risks due to the fact that the systems and applications for the power grid were not originally designed for the general IT environment. In this paper, we propose a conceptual layered framework for protecting power grid automation systems against cyber attacks. The following factors are taken into account: (1) integration with existing, legacy systems in a non-intrusive fashion; (2) desirable performance in terms of modularity, scalability, extendibility, and manageability; (3) alignment to the 'Roadmap to Secure Control Systems in the Energy Sector' and the future smart grid. The on-site system test of the developed prototype security system is briefly presented as well.

  16. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1310 Power... storage device. (3) Essential loads after failure of— (i) Any one engine on two-engine airplanes; and (ii) Any two engines on airplanes with three or more engines. (4) Essential loads for which an...

  17. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1310 Power... storage device. (3) Essential loads after failure of— (i) Any one engine on two-engine airplanes; and (ii) Any two engines on airplanes with three or more engines. (4) Essential loads for which an...

  18. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1310 Power... storage device. (3) Essential loads after failure of— (i) Any one engine on two-engine airplanes; and (ii) Any two engines on airplanes with three or more engines. (4) Essential loads for which an...

  19. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1310 Power... storage device. (3) Essential loads after failure of— (i) Any one engine on two-engine airplanes; and (ii) Any two engines on airplanes with three or more engines. (4) Essential loads for which an...

  20. 14 CFR 25.1310 - Power source capacity and distribution.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment General § 25.1310 Power... storage device. (3) Essential loads after failure of— (i) Any one engine on two-engine airplanes; and (ii) Any two engines on airplanes with three or more engines. (4) Essential loads for which an...

  1. Photovoltaic Power System and Power Distribution Demonstration for the Desert RATS Program

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony; Jakupca, Ian; Mintz, Toby; Herlacher, Mike; Hussey, Sam

    2012-01-01

    A stand alone, mobile photovoltaic power system along with a cable deployment system was designed and constructed to take part in the Desert Research And Technology Studies (RATS) lunar surface human interaction evaluation program at Cinder Lake, Arizona. The power system consisted of a photovoltaic array/battery system. It is capable of providing 1 kW of electrical power. The system outputs were 48 V DC, 110 V AC, and 220 V AC. A cable reel with 200 m of power cable was used to provide power from the trailer to a remote location. The cable reel was installed on a small trailer. The reel was powered to provide low to no tension deployment of the cable. The cable was connected to the 220 V AC output of the power system trailer. The power was then converted back to 110 V AC on the cable deployment trailer for use at the remote site. The Scout lunar rover demonstration vehicle was used to tow the cable trailer and deploy the power cable. This deployment was performed under a number of operational scenarios, manned operation, remote operation and tele-robotically. Once deployed, the cable was used to provide power, from the power system trailer, to run various operational tasks at the remote location.

  2. Modeling, control, and dispatch of photovoltaic-based power distribution systems

    NASA Astrophysics Data System (ADS)

    Carrasco, Miguel

    Small-scale generators, also called distributed generators (DGs), are primed to play a central role in future distribution systems. If properly integrated, DGs present two main advantages: (i) they help decongest existing transmission grids; and (ii) CO2 emissions are reduced since most DGs are based on renewables like wind and solar. Their integration into distribution systems is one of the main challenges the power industry will be facing in the coming years. Photovoltaic (PV) power generation represents a key technology for realizing the DG concept. In this dissertation, technical solutions are developed that enable an increased penetration of PV systems, while improving the efficiency, reliability, and power quality of power distribution grids. The presented research spans from PV array modeling, parameter identification and estimation methods, through advanced control strategies for the power electronic interfaces, to system--level optimal dispatch strategies. Simulation-based and experimental validation results show the performance of the proposed techniques.

  3. Nonactive-Power-Related Ancillary Services provided by Distribute Energy Resources

    SciTech Connect

    Xu, Yan; Tolbert, Leon M; Rizy, D Tom; Kueck, John D

    2006-01-01

    The nonactive-power-related ancillary services provided by distributed energy (DE) resources are categorized by voltage regulation, reactive power compensation, power factor correction, voltage and/or current unbalance compensation, and harmonics compensation. An instantaneous nonactive power theory is adopted to control the DE system to provide these ancillary services. Three control schemes, including nonactive current compensation, power factor correction, and voltage regulation, are developed which can perform one or more of the ancillary services. The control schemes are implemented in a DE system in simulation and experiments. The simulation and the experimental results show that DE is feasible for providing nonactive-power-related ancillary services.

  4. Computer model for electrochemical cell performance loss over time in terms of capacity, power, and conductance (CPC)

    SciTech Connect

    Gering, Kevin L.

    2015-09-01

    Available capacity, power, and cell conductance figure centrally into performance characterization of electrochemical cells (such as Li-ion cells) over their service life. For example, capacity loss in Li-ion cells is due to a combination of mechanisms, including loss of free available lithium, loss of active host sites, shifts in the potential-capacity curve, etc. Further distinctions can be made regarding irreversible and reversible capacity loss mechanisms. There are tandem needs for accurate interpretation of capacity at characterization conditions (cycling rate, temperature, etc.) and for robust self-consistent modeling techniques that can be used for diagnostic analysis of cell data as well as forecasting of future performance. Analogous issues exist for aging effects on cell conductance and available power. To address these needs, a modeling capability was developed that provides a systematic analysis of the contributing factors to battery performance loss over aging and to act as a regression/prediction platform for cell performance. The modeling basis is a summation of self-consistent chemical kinetics rate expressions, which as individual expressions each covers a distinct mechanism (e.g., loss of active host sites, lithium loss), but collectively account for the net loss of premier metrics (e.g., capacity) over time for a particular characterization condition. Specifically, sigmoid-based rate expressions are utilized to describe each contribution to performance loss. Through additional mathematical development another tier of expressions is derived and used to perform differential analyses and segregate irreversible versus reversible contributions, as well as to determine concentration profiles over cell aging for affected Li+ ion inventory and fraction of active sites that remain at each time step. Reversible fade components are surmised by comparing fade rates at fast versus slow cycling conditions. The model is easily utilized for predictive

  5. Distributed Leadership: The Uses and Abuses of Power

    ERIC Educational Resources Information Center

    Lumby, Jacky

    2013-01-01

    In about a decade the theory of distributed leadership has moved from a tool to better understand the ecology of leadership to a widely prescribed practice. This article considers how to account for its spread and dominance and what purpose it serves. The concept offers an enticing suggestion of including more in leadership, and even sometimes…

  6. Space power distribution system technology. Volume 1: Reference EPS design

    NASA Technical Reports Server (NTRS)

    Decker, D. K.; Cannady, M. D.; Cassinelli, J. E.; Farber, B. F.; Lurie, C.; Fleck, G. W.; Lepisto, J. W.; Massner, A.; Ritterman, P. F.

    1983-01-01

    The multihundred kilowatt electrical power aspects of a mannable space platform in low Earth orbit is analyzed from a cost and technology viewpoint. At the projected orbital altitudes, Shuttle launch and servicing are technically and economically viable. Power generation is specified as photovoltaic consistent with projected planning. The cost models and trades are based upon a zero interest rate (the government taxes concurrently as required), constant dollars (1980), and costs derived in the first half of 1980. Space platform utilization of up to 30 years is evaluated to fully understand the impact of resupply and replacement as satellite missions are extended. Such lifetimes are potentially realizable with Shuttle servicing capability and are economically desirable.

  7. Light propagation characteristics in photonic crystal fibers with α-power profiles of air hole diameter distributions and their application to fiber collimator

    NASA Astrophysics Data System (ADS)

    Yokota, Hirohisa; Higuchi, Keiichi; Imai, Yoh

    2016-08-01

    Light propagation characteristics in photonic crystal fibers (PCFs) with α-power profiles of air hole diameter distributions were theoretically investigated. It was clarified that the intensity peak of the beam propagating in the PCF with Gaussian beam excitation varied periodically with little power attenuation. It was found that the envelope of the periodic intensity variation depended on α. We theoretically demonstrated that the PCF with the α-power profile of the air hole diameter distribution could be applied to a collimator for a conventional PCF with uniform air holes in Gaussian beam excitation to reduce coupling loss, where a PCF of appropriate length with the α-power air hole diameter distribution was spliced to a conventional PCF. It was also found that the coupling efficiency was higher for a larger α.

  8. Large space systems technology electronics: Data and power distribution

    NASA Astrophysics Data System (ADS)

    Dunbar, W. G.

    1980-02-01

    The development of hardware technology and manufacturing techniques required to meet space platform and antenna system needs in the 1980s is discussed. Preliminary designs for manned and automatically assembled space power system cables, connectors, and grounding and bonding materials and techniques are reviewed. Connector concepts, grounding design requirements, and bonding requirements are discussed. The problem of particulate debris contamination for large structure spacecraft is addressed.

  9. Large space systems technology electronics: Data and power distribution

    NASA Technical Reports Server (NTRS)

    Dunbar, W. G.

    1980-01-01

    The development of hardware technology and manufacturing techniques required to meet space platform and antenna system needs in the 1980s is discussed. Preliminary designs for manned and automatically assembled space power system cables, connectors, and grounding and bonding materials and techniques are reviewed. Connector concepts, grounding design requirements, and bonding requirements are discussed. The problem of particulate debris contamination for large structure spacecraft is addressed.

  10. Cascading Failures in Coupled Distributed Power Grids and Communication Networks

    DTIC Science & Technology

    2013-08-01

    system structure design We considered the control and communication system of the power grid as a hierarchical system . Control and communication...would perform the local control actions as well as implementing necessary remote control signals. We decomposed the transmission grid into sub- systems ...based on the control regions defined over it. We assumed that in each sub- system , the control regions utilized controlling and monitoring agents

  11. Load flow and state estimation algorithms for three-phase unbalanced power distribution systems

    NASA Astrophysics Data System (ADS)

    Madvesh, Chiranjeevi

    Distribution load flow and state estimation are two important functions in distribution energy management systems (DEMS) and advanced distribution automation (ADA) systems. Distribution load flow analysis is a tool which helps to analyze the status of a power distribution system under steady-state operating conditions. In this research, an effective and comprehensive load flow algorithm is developed to extensively incorporate the distribution system components. Distribution system state estimation is a mathematical procedure which aims to estimate the operating states of a power distribution system by utilizing the information collected from available measurement devices in real-time. An efficient and computationally effective state estimation algorithm adapting the weighted-least-squares (WLS) method has been developed in this research. Both the developed algorithms are tested on different IEEE test-feeders and the results obtained are justified.

  12. Anode-cathode power distribution systems and methods of using the same for electrochemical reduction

    DOEpatents

    Koehl, Eugene R; Barnes, Laurel A; Wiedmeyer, Stanley G; Williamson, Mark A; Willit, James L

    2014-01-28

    Power distribution systems are useable in electrolytic reduction systems and include several cathode and anode assembly electrical contacts that permit flexible modular assembly numbers and placement in standardized connection configurations. Electrical contacts may be arranged at any position where assembly contact is desired. Electrical power may be provided via power cables attached to seating assemblies of the electrical contacts. Cathode and anode assembly electrical contacts may provide electrical power at any desired levels. Pairs of anode and cathode assembly electrical contacts may provide equal and opposite electrical power; different cathode assembly electrical contacts may provide different levels of electrical power to a same or different modular cathode assembly. Electrical systems may be used with an electrolyte container into which the modular cathode and anode assemblies extend and are supported above, with the modular cathode and anode assemblies mechanically and electrically connecting to the respective contacts in power distribution systems.

  13. Distributions of TEC Fluctuations and Losses of Lock Associated with Equatorial Plasma Bubbles

    NASA Astrophysics Data System (ADS)

    Nakata, H.; Kikuchi, H.; Tsugawa, T.; Otsuka, Y.; Takano, T.; Shimakura, S.; Shiokawa, K.; Ogawa, T.

    2009-12-01

    Equatorial plasma bubbles (EPBs) are local depletions of the electron density in the ionosphere. Due to field-aligned irregularities (FAIs) with various spatial scales, EPBs affect wide-band radio waves and cause scintillations in GPS navigation system. Strong scintillation can cause a GPS receiver to lose lock on GPS signals because of rapid variations of signal amplitude and phase, and limit the availability of carrier phase measurements. Since the scintillation is caused by Fresnel diffraction, the spatial scale of FAIs that causes the scintillation of GPS signals is about 2-300 m. Therefore, loss of phase lock (LOL) on GPS signals is a reference of hundred-meter-scale FAIs. As EPBs are also associated with fluctuations of the total electron content (TEC), the enhancement of Rate of TEC change index (ROTI) occurs around EPBs. Assuming that the altitude of the ionosphere is about 400 km, the velocity of the pierce point of the GPS radio wave at the ionospheric altitude is approximately 70 m/s around the zenith. Thus, ROTI averaged during 5 minutes is a reference of ten-kilometer-scale fluctuations. In this study, we analyzed LOL and 5-min. ROTI associated with EPBs to examine the spatial and temporal scales of electron density disturbances associated with EPBs. We selected 11 EPBs from 630-nm airglow images obtained by all-sky imager at Sata, Japan, in 2001. LOL and ROTI are obtained from GPS data from GPS Earth Observation Network (GEONET) of Japan, which consists of more than 1000 GPS receivers. As a result, it is shown that both LOL and the enhancement of ROTI are observed in 8 events out of 11 events. The distributions of LOL are approximately consistent with the areas in which the ionospheric electron density is depleted. The enhancements of ROTI are observed in the vicinities of EPBs. The enhancement of ROTI expands especially in the west side of EPBs. After the EPBs pass through, therefore, LOLs are vanished but the enhancements of ROTI last a while. This

  14. Multiple-scattering distributions and angular dependence of the energy loss of slow protons in copper and silver

    NASA Astrophysics Data System (ADS)

    Cantero, E. D.; Lantschner, G. H.; Eckardt, J. C.; Lovey, F. C.; Arista, N. R.

    2010-04-01

    Measurements of angular distributions and of the angular dependence of the energy loss of 4-, 6-, and 9-keV protons transmitted through thin Cu and Ag polycrystalline foils are presented. By means of standard multiple-scattering model calculations it is found that a V(r)∝r-2.8 potential leads to significantly better fits of the angular distributions than the standard Thomas Fermi, Lenz-Jensen, or Ziegler-Biersack-Littmark potentials. A theoretical model for the angular dependence of the energy loss based on considering geometric effects on a frictional inelastic energy loss plus an angular-dependent elastic contribution and the effects of foil roughness reproduces the experimental data. This agrees with previous results in Au and Al, therefore extending the applicability of the model to other metallic elements.

  15. The Power of Heterogeneity: Parameter Relationships from Distributions

    PubMed Central

    Röding, Magnus; Bradley, Siobhan J.; Williamson, Nathan H.; Dewi, Melissa R.; Nann, Thomas; Nydén, Magnus

    2016-01-01

    Complex scientific data is becoming the norm, many disciplines are growing immensely data-rich, and higher-dimensional measurements are performed to resolve complex relationships between parameters. Inherently multi-dimensional measurements can directly provide information on both the distributions of individual parameters and the relationships between them, such as in nuclear magnetic resonance and optical spectroscopy. However, when data originates from different measurements and comes in different forms, resolving parameter relationships is a matter of data analysis rather than experiment. We present a method for resolving relationships between parameters that are distributed individually and also correlated. In two case studies, we model the relationships between diameter and luminescence properties of quantum dots and the relationship between molecular weight and diffusion coefficient for polymers. Although it is expected that resolving complicated correlated relationships require inherently multi-dimensional measurements, our method constitutes a useful contribution to the modelling of quantitative relationships between correlated parameters and measurements. We emphasise the general applicability of the method in fields where heterogeneity and complex distributions of parameters are obstacles to scientific insight. PMID:27182701

  16. Analysis of Power Quality Based on Real Data and Quality Improvement at Campus Distribution System

    NASA Astrophysics Data System (ADS)

    Kawasaki, Shoji; Matsuki, Junya; Hayashi, Yasuhiro; Ito, Akitoshi

    In recent years, a lot of equipments have been made using the inverter technology from home electric appliances to office automation apparatuses and industrial equipments with the development of power electronics technology. The voltage distortion of a distribution system has increased due to the harmonic currents generated from these apparatuses, and the increase in harmonics continues to be expected. In addition, the distribution system forms the circuit of harmonic distortion expansion by the prevalence of static capacitor without L for power factor improvement. Moreover, the voltage imbalance occurs by diversification of loads or imbalanced connection of single-phase loads. The deterioration of power quality in the distribution system causes various problems such as the overheating of equipments and malfunction of rotating machines. Since the power quality changes according to air temperature and date, it is desirable to measure the voltages and currents continuously for a long time. In this study, the authors focus attention on the distribution system in the University of Fukui campus, and the authors have measured the voltages and currents in the distribution system for a long period with WAMS (Wide Area Measurement System) using NCT (Network Computing Terminal). Based on the obtained data, the authors analyzed the power quality of the campus distribution system from viewpoints of voltage imbalance, current imbalance, voltage THD (Total Harmonic Distortion), and current THD. Furthermore, the improvement effect of power quality of the campus distribution system by exchange of single-phase load connection is described.

  17. Distributed Processing System for Restoration of Electric Power Distribution Network Using Two-Layered Contract Net Protocol

    NASA Astrophysics Data System (ADS)

    Kodama, Yu; Hamagami, Tomoki

    Distributed processing system for restoration of electric power distribution network using two-layered CNP is proposed. The goal of this study is to develop the restoration system which adjusts to the future power network with distributed generators. The state of the art of this study is that the two-layered CNP is applied for the distributed computing environment in practical use. The two-layered CNP has two classes of agents, named field agent and operating agent in the network. In order to avoid conflicts of tasks, operating agent controls privilege for managers to send the task announcement messages in CNP. This technique realizes the coordination between agents which work asynchronously in parallel with others. Moreover, this study implements the distributed processing system using a de-fact standard multi-agent framework, JADE(Java Agent DEvelopment framework). This study conducts the simulation experiments of power distribution network restoration and compares the proposed system with the previous system. We confirmed the results show effectiveness of the proposed system.

  18. Determining the distribution loss of brown eared-pheasant (Crossoptilon mantchuricum) using historical data and potential distribution estimates.

    PubMed

    Li, Yilin; Li, Xinhai; Song, Zitan; Ding, Changqing

    2016-01-01

    We analyzed the synchronous relationship between forest cover and species distribution to explain the contraction in the distribution range of the brown eared-pheasant (Crossoptilon mantchuricum) in China. Historical resources can provide effective records for reconstructing long-term distribution dynamics. The brown eared-pheasant's historical distribution from 25 to 1947 CE, which included the three provinces of Shaanxi, Shanxi, and Hebei based on this species' habitat selection criteria, the history of the forests, ancient climate change records, and fossil data. The current species distribution covers Shaanxi, Shanxi, and Hebei provinces, as well as Beijing city, while Shanxi remains the center of the distribution area. MaxEnt model indicated that the suitable conditions of the brown eared-pheasant had retreated to the western regions of Shanxi and that the historical distribution area had reduced synchronously with the disappearance of local forest cover in Shanxi. We built a correlative relationship between the presence/absence of brown eared-pheasants and forest coverage and found that forest coverage in the north, northeast, central, and southeast areas of the Shanxi province were all less than 10% in 1911. Wild brown eared-pheasants are stable in the Luliang Mountains, where forest coverage reached 13.2% in 2000. Consequently, we concluded that the distribution of this species is primarily determined by vegetation conditions and that forest cover was the most significant determining factor.

  19. Determining the distribution loss of brown eared-pheasant (Crossoptilon mantchuricum) using historical data and potential distribution estimates

    PubMed Central

    Song, Zitan

    2016-01-01

    We analyzed the synchronous relationship between forest cover and species distribution to explain the contraction in the distribution range of the brown eared-pheasant (Crossoptilon mantchuricum) in China. Historical resources can provide effective records for reconstructing long-term distribution dynamics. The brown eared-pheasant’s historical distribution from 25 to 1947 CE, which included the three provinces of Shaanxi, Shanxi, and Hebei based on this species’ habitat selection criteria, the history of the forests, ancient climate change records, and fossil data. The current species distribution covers Shaanxi, Shanxi, and Hebei provinces, as well as Beijing city, while Shanxi remains the center of the distribution area. MaxEnt model indicated that the suitable conditions of the brown eared-pheasant had retreated to the western regions of Shanxi and that the historical distribution area had reduced synchronously with the disappearance of local forest cover in Shanxi. We built a correlative relationship between the presence/absence of brown eared-pheasants and forest coverage and found that forest coverage in the north, northeast, central, and southeast areas of the Shanxi province were all less than 10% in 1911. Wild brown eared-pheasants are stable in the Luliang Mountains, where forest coverage reached 13.2% in 2000. Consequently, we concluded that the distribution of this species is primarily determined by vegetation conditions and that forest cover was the most significant determining factor. PMID:27781161

  20. Synergy of inelastic and elastic energy loss. Temperature effects and electronic stopping power dependence

    DOE PAGES

    Zarkadoula, Eva; Xue, Haizhou; Zhang, Yanwen; ...

    2015-06-16

    A combination of an inelastic thermal spike model suitable for insulators and molecular dynamics simulations is used to study the effects of temperature and electronic energy loss on ion track formation, size and morphology in SrTiO3 systems with pre-existing disorder. We find temperature dependence of the ion track size. In addition, we find a threshold in the electronic energy loss for a given pre-existing defect concentration, which indicates a threshold in the synergy between the inelastic and elastic energy loss.

  1. Synergy of inelastic and elastic energy loss. Temperature effects and electronic stopping power dependence

    SciTech Connect

    Zarkadoula, Eva; Xue, Haizhou; Zhang, Yanwen; Weber, William J.

    2015-06-16

    A combination of an inelastic thermal spike model suitable for insulators and molecular dynamics simulations is used to study the effects of temperature and electronic energy loss on ion track formation, size and morphology in SrTiO3 systems with pre-existing disorder. We find temperature dependence of the ion track size. In addition, we find a threshold in the electronic energy loss for a given pre-existing defect concentration, which indicates a threshold in the synergy between the inelastic and elastic energy loss.

  2. GENERIC VERIFICATION PROTOCOL: DISTRIBUTED GENERATION AND COMBINED HEAT AND POWER FIELD TESTING PROTOCOL

    EPA Science Inventory

    This report is a generic verification protocol by which EPA’s Environmental Technology Verification program tests newly developed equipment for distributed generation of electric power, usually micro-turbine generators and internal combustion engine generators. The protocol will ...

  3. A multi-agent approach for a self-reconfigurable electric power distribution system

    NASA Astrophysics Data System (ADS)

    Gómez–Gualdrón, Janeth G.; Vélez-Reyes, Miguel

    2006-05-01

    Electric power distribution systems can be found almost everywhere, from ship power systems to data centers. In many critical applications, there is needed to maintain minimal operating capability under fault conditions. To carry out this goal it is necessary to develop energy distribution control techniques, which let implement a self-reconfigurable energy distribution system. This research project is looking at the implementation of multi-agent systems to develop a self-reconfigurable electric power distribution system. A prototype of a Multi-Agent system is proposed to reconfigure the system in order to maximize the number of served loads with highest priority. The shipboard power system is simulated in Matlab TM Simulink TM and the Multi-Agent System is implemented using Java programming language and JADE platform.

  4. Do wealth distributions follow power laws? Evidence from ‘rich lists’

    NASA Astrophysics Data System (ADS)

    Brzezinski, Michal

    2014-07-01

    We use data on the wealth of the richest persons taken from the 'rich lists' provided by business magazines like Forbes to verify if the upper tails of wealth distributions follow, as often claimed, a power-law behaviour. The data sets used cover the world's richest persons over 1996-2012, the richest Americans over 1988-2012, the richest Chinese over 2006-2012, and the richest Russians over 2004-2011. Using a recently introduced comprehensive empirical methodology for detecting power laws, which allows for testing the goodness of fit as well as for comparing the power-law model with rival distributions, we find that a power-law model is consistent with data only in 35% of the analysed data sets. Moreover, even if wealth data are consistent with the power-law model, they are usually also consistent with some rivals like the log-normal or stretched exponential distributions.

  5. Influence of laser power on atom probe tomographic analysis of boron distribution in silicon.

    PubMed

    Tu, Y; Takamizawa, H; Han, B; Shimizu, Y; Inoue, K; Toyama, T; Yano, F; Nishida, A; Nagai, Y

    2017-02-01

    The relationship between the laser power and the three-dimensional distribution of boron (B) in silicon (Si) measured by laser-assisted atom probe tomography (APT) is investigated. The ultraviolet laser employed in this study has a fixed wavelength of 355nm. The measured distributions are almost uniform and homogeneous when using low laser power, while clear B accumulation at the low-index pole of single-crystalline Si and segregation along the grain boundaries in polycrystalline Si are observed when using high laser power (100pJ). These effects are thought to be caused by the surface migration of atoms, which is promoted by high laser power. Therefore, for ensuring a high-fidelity APT measurement of the B distribution in Si, high laser power is not recommended.

  6. A Model to Predict Shelf-Life Loss Ofhorticultural Produce During Distribution Withfluctuated Temperature and Vehicle Vibration

    NASA Astrophysics Data System (ADS)

    Gong, Weiwei; Li, Daoliang; Liu, Xue; Yue, Jun; Fu, Zetian

    Fresh fruits and vegetables has become a public concern from the food security aspect. And the prediction of shelf-life loss under the fluctuated temperature becomes one of the key problems in food supply chain operation. So this paper identifies the impact aspects of produce decaying during distribution. For the key temperature factor, the process is divided into three phases: sorting, traveling and door-opening. Based on time-temperature function, a model of shelf-life loss of horticultural produce during distribution is developed by evaluating respiration rate of vegetables and fruits considering both the environment fluctuated temperature and vehicle vibration during traveling. Taking eggplant as an example, the numerical experiment result demonstrates that the average cost for ambient distribution is 2.8 times of the insulation way.

  7. Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/electrical power generation subsystem

    NASA Technical Reports Server (NTRS)

    Patton, Jeff A.

    1986-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C)/Electrical Power Generation (EPG) hardware. The EPD and C/EPG hardware is required for performing critical functions of cryogenic reactant storage, electrical power generation and product water distribution in the Orbiter. Specifically, the EPD and C/EPG hardware consists of the following components: Power Section Assembly (PSA); Reactant Control Subsystem (RCS); Thermal Control Subsystem (TCS); Water Removal Subsystem (WRS); and Power Reactant Storage and Distribution System (PRSDS). The IOA analysis process utilized available EPD and C/EPG hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

  8. Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

    NASA Technical Reports Server (NTRS)

    Jeffries, K. S.; Renz, D. D.

    1984-01-01

    A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

  9. The Case for Natural Gas Fueled Solid Oxide Fuel Cell Power Systems for Distributed Generation

    SciTech Connect

    Chick, Lawrence A.; Weimar, Mark R.; Whyatt, Greg A.; Powell, Michael R.

    2015-02-01

    Natural-gas-fueled solid oxide fuel cell (NGSOFC) power systems yield electrical conversion efficiencies exceeding 60% and may become a viable alternative for distributed generation (DG) if stack life and manufacturing economies of scale can be realized. Currently, stacks last approximately 2 years and few systems are produced each year because of the relatively high cost of electricity from the systems. If mass manufacturing (10,000 units per year) and a stack life of 15 years can be reached, the cost of electricity from an NGSOFC system is estimated to be about 7.7 ¢/kWh, well within the price of commercial and residential retail prices at the national level (9.9-10¢/kWh and 11-12 ¢/kWh, respectively). With an additional 5 ¢/kWh in estimated additional benefits from DG, NGSOFC could be well positioned to replace the forecasted 59-77 gigawatts of capacity loss resulting from coal plant closures due to stricter emissions regulations and low natural gas prices.

  10. Stationarity of the inter-event power-law distributions

    PubMed Central

    2017-01-01

    A number of human activities exhibit a bursty pattern, namely periods of very high activity that are followed by rest periods. Records of these processes generate time series of events whose inter-event times follow a probability distribution that displays a fat tail. The grounds for such phenomenon are not yet clearly understood. In the present work we use the freely available Wikipedia’s editing records to unravel some features of this phenomenon. We show that even though the probability to start editing is conditioned by the circadian 24 hour cycle, the conditional probability for the time interval between successive edits at a given time of the day is independent from the latter. We confirm our findings with the activity of posting on the social network Twitter. Our results suggest that there is an intrinsic humankind scheduling pattern: after overcoming the encumbrance of starting an activity, there is a robust distribution of new related actions, which does not depend on the time of day at which the activity started. PMID:28346480

  11. Application of the mobility power flow approach to structural response from distributed loading

    NASA Technical Reports Server (NTRS)

    Cuschieri, J. M.

    1988-01-01

    The problem of the vibration power flow through coupled substructures when one of the substructures is subjected to a distributed load is addressed. In all the work performed thus far, point force excitation was considered. However, in the case of the excitation of an aircraft fuselage, distributed loading on the whole surface of a panel can be as important as the excitation from directly applied forces at defined locations on the structures. Thus using a mobility power flow approach, expressions are developed for the transmission of vibrational power between two coupled plate substructures in an L configuration, with one of the surfaces of one of the plate substructures being subjected to a distributed load. The types of distributed loads that are considered are a force load with an arbitrary function in space and a distributed load similar to that from acoustic excitation.

  12. Power-law and exponential rank distributions: A panoramic Gibbsian perspective

    SciTech Connect

    Eliazar, Iddo

    2015-04-15

    Rank distributions are collections of positive sizes ordered either increasingly or decreasingly. Many decreasing rank distributions, formed by the collective collaboration of human actions, follow an inverse power-law relation between ranks and sizes. This remarkable empirical fact is termed Zipf’s law, and one of its quintessential manifestations is the demography of human settlements — which exhibits a harmonic relation between ranks and sizes. In this paper we present a comprehensive statistical-physics analysis of rank distributions, establish that power-law and exponential rank distributions stand out as optimal in various entropy-based senses, and unveil the special role of the harmonic relation between ranks and sizes. Our results extend the contemporary entropy-maximization view of Zipf’s law to a broader, panoramic, Gibbsian perspective of increasing and decreasing power-law and exponential rank distributions — of which Zipf’s law is one out of four pillars.

  13. Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants

    SciTech Connect

    Agamy, Mohammed; Elasser, Ahmed; Sabate, Juan Antonio; Galbraith, Anthony William; Harfman Todorovic, Maja

    2014-09-09

    A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

  14. A new field-sensing method to measure the power loss of electrical steel sheet under two-dimensional measuring conditions

    SciTech Connect

    Birkfeld, M.; Hempel, K.A.

    1996-09-01

    A sensor system is proposed that allows a fast and integral measurement of the power loss in the sample volume independent of the geometry and positioning of the sample in the setup. The power loss is determined under various two-dimensional measuring conditions. The obtained values are compared to those investigated with standard methods.

  15. High power singlemode GaInAs lasers with distributed Bragg reflectors

    NASA Technical Reports Server (NTRS)

    O'Brien, S.; Parke, R.; Welch, D. F.; Mehuys, D.; Scifres, D.

    1992-01-01

    High power singlemode strained GaInAs lasers have been fabricated which use buried second order gratings as distributed Bragg reflectors. The lasers operate in an edge emitting fashion with CW powers in excess of 110 mW with single longitudinal and transverse mode operation at 971.9 nm up to 42 mW.

  16. Power of the Independent Samples t Test under a Prevalent Psychometric Measure Distribution.

    ERIC Educational Resources Information Center

    Sawilowsky, Shlomo S.; Hillman, Stephen B.

    1992-01-01

    Notes that studies in psychology often have low power because of inadequate sample size and that prevalent psychometric distributions are sometimes radically nonnormal. Demonstrates robustness of independent samples t-test with respect to Type I error. Shows that researchers may use power tables based on population normality without modification…

  17. Electrical Power Transmission and Distribution Safety. Module SH-40. Safety and Health.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on electrical power transmission and distribution safety is one of 50 modules concerned with job safety and health. This module focuses on some of the general safety rules, techniques, and procedures that are essential in establishing a safe environment for the electrical power transmission worker. Following the introduction,…

  18. Power Distribution and Adoption of Agricultural Innovations: A Structural Analysis of Villages in Pakistan.

    ERIC Educational Resources Information Center

    Freeman, David M.; And Others

    1982-01-01

    Data collected from a sample of farmers representing 15 Pakistani villages show that greater equality in village power distribution is positively related to greater adoption of agricultural technology as analyzed at the village level. When effects of water control are parceled out, the power-adoption relationship is strengthened. (LC)

  19. Minimization of the energy loss of nuclear power plants in case of partial in-core monitoring system failure

    NASA Astrophysics Data System (ADS)

    Zagrebaev, A. M.; Ramazanov, R. N.; Lunegova, E. A.

    2017-01-01

    In this paper we consider the optimization problem minimize of the energy loss of nuclear power plants in case of partial in-core monitoring system failure. It is possible to continuation of reactor operation at reduced power or total replacement of the channel neutron measurements, requiring shutdown of the reactor and the stock of detectors. This article examines the reconstruction of the energy release in the core of a nuclear reactor on the basis of the indications of height sensors. The missing measurement information can be reconstructed by mathematical methods, and replacement of the failed sensors can be avoided. It is suggested that a set of ‘natural’ functions determined by means of statistical estimates obtained from archival data be constructed. The procedure proposed makes it possible to reconstruct the field even with a significant loss of measurement information. Improving the accuracy of the restoration of the neutron flux density in partial loss of measurement information to minimize the stock of necessary components and the associated losses.

  20. Calculated power distribution of a thermionic, beryllium oxide reflected, fast-spectrum reactor

    NASA Technical Reports Server (NTRS)

    Mayo, W.; Lantz, E.

    1973-01-01

    A procedure is developed and used to calculate the detailed power distribution in the fuel elements next to a beryllium oxide reflector of a fast-spectrum, thermionic reactor. The results of the calculations show that, although the average power density in these outer fuel elements is not far from the core average, the power density at the very edge of the fuel closest to the beryllium oxide is about 1.8 times the core avearge.

  1. Technology survey of electrical power generation and distribution for MIUS application

    NASA Technical Reports Server (NTRS)

    Gill, W. L.; Redding, T. E.

    1975-01-01

    Candidate electrical generation power systems for the modular integrated utility systems (MIUS) program are described. Literature surveys were conducted to cover both conventional and exotic generators. Heat-recovery equipment associated with conventional power systems and supporting equipment are also discussed. Typical ranges of operating conditions and generating efficiencies are described. Power distribution is discussed briefly. Those systems that appear to be applicable to MIUS have been indicated, and the criteria for equipment selection are discussed.

  2. Impact of Distributed Wind on Bulk Power System Operations in ISO-NE (Presentation)

    SciTech Connect

    Brancucci Martinez-Anido, C.; Hodge, B. M.; Palchak, D.; Miettinen, J.

    2014-11-01

    The work presented in the paper corresponding to this presentation aims to study the impact of a range of penetration levels of distributed wind on the operation of the electric power system at the transmission level. This presentation is an overview of a case study on the power system in Independent System Operator New England. It is analyzed using PLEXOS, a commercial power system simulation tool

  3. Performance and Economic Analysis of Distributed Power Electronics in Photovoltaic Systems

    SciTech Connect

    Deline, C.; Marion, B.; Granata, J.; Gonzalez, S.

    2011-01-01

    Distributed electronics like micro-inverters and DC-DC converters can help recover mismatch and shading losses in photovoltaic (PV) systems. Under partially shaded conditions, the use of distributed electronics can recover between 15-40% of annual performance loss or more, depending on the system configuration and type of device used. Additional value-added features may also increase the benefit of using per-panel distributed electronics, including increased safety, reduced system design constraints and added monitoring and diagnostics. The economics of these devices will also become more favorable as production volume increases, and integration within the solar panel?s junction box reduces part count and installation time. Some potential liabilities of per-panel devices include increased PV system cost, additional points of failure, and an insertion loss that may or may not offset performance gains under particular mismatch conditions.

  4. Effects of non-uniform distributions of gain and loss in photonic crystals

    NASA Astrophysics Data System (ADS)

    Cerjan, Alexander; Fan, Shanhui

    2016-12-01

    We present a {k}\\cdot {p} theory of photonic crystals containing gain and loss in which the gain and loss are added to separate primitive cells of the underlying Hermitian system, thereby creating a supercell photonic crystal. We show that the supercell bands of this system can merge outward from the degenerate contour formed from folding the bands of the underlying Hermitian system into the supercell Brillouin zone, but that other accidental degeneracies in the band structure of the underlying Hermitian system do not yield band merging behavior. Finally, we show that the modal coupling matrix in PhCs with balanced gain and loss is trace-less, and thus the imaginary components of the eigenvalues can only move relative to one another as the strength of the gain and loss is varied, without any collective motion.

  5. Industry sector analysis, Indonesia: Electric power distribution equipment. Export trade information

    SciTech Connect

    Sihombing, P.

    1991-08-20

    The market survey covers the electric power distribution equipment market in Indonesia. The analysis contains statistical and narrative information on projected market demand, end-users; receptivity of Indonesian consumers to U.S. products; the competitive situation, and market access (tariffs, non-tariff barriers, standards, taxes, distribution channels). It also contains key contact information.

  6. Exponential and power-law contact distributions represent different atmospheric conditions.

    PubMed

    Reynolds, A M

    2011-12-01

    It is well known that the dynamics of plant disease epidemics are very sensitive to the functional form of the contact distribution?the probability distribution function for the distance of viable fungal spore movement until deposition. Epidemics can take the form of a constant-velocity travelling wave when the contact distribution is exponentially bounded. Fat-tailed contact distributions, on the other hand, lead to epidemic spreads that accelerate over time. Some empirical data for contact distributions can be well represented by negative exponentials while other data are better represented by fat-tailed inverse power laws. Here we present data from numerical simulations that suggest that negative exponentials and inverse power laws are not competing candidate forms of the contact distribution but are instead representative of different atmospheric conditions. Contact distributions for atmospheric boundary-layers with stabilities ranging from strongly convective (a hot windless day time scenario) to stable stratification (a cold windy night time scenario) but without precipitation events are calculated using well-established state-of-the-art Lagrangian stochastic (particle tracking) dispersal models. Contact distributions are found to be well represented by exponentials for strongly convective conditions; a -3/2 inverse power law for convective boundary-layers with wind shear; and by a -2/3 inverse power law for stably stratified conditions.

  7. Progress in L-Band Power Distribution System R&D at SLAC

    SciTech Connect

    Nantista, Christopher; Adolphsen, Chris; Wang, Faya; /SLAC

    2008-10-20

    We report on the L-band RF power distribution system (PDS) developed at SLAC for Fermilab's NML superconducting test accelerator facility. The makeup of the system, which allows tailoring of the power distribution to cavities by pairs, is briefly described. Cold test measurements of the system and the results of high power processing are presented. We also investigate the feasibility of eliminating the expensive, lossy circulators from the PDS by pair-feeding cavities through custom 3-dB hybrids. A computational model is used to simulate the impact on cavity field stability due to the reduced cavity-to-cavity isolation.

  8. Dielectric spectroscopy measurements on very low loss cross-linked polyethylene power cables

    NASA Astrophysics Data System (ADS)

    Liu, Tong; Fothergill, John; Dodd, Steve; Nilsson, Ulf

    2009-08-01

    The principles of dielectric spectroscopy are reviewed and the techniques in both time and frequency domains are explored in search of appropriate methods for measurement on low loss XLPE cables. By combining the techniques of frequency response analyzer, transformer ratio bridge and discharging current measurements, some preliminary tests results on homopolymer XLPE model cables have been presented and analyzed, in a wide frequency range of 10-4Hz~2×104Hz. Dielectric loss mechanisms of XLPE cables are discussed based on the measurement results.

  9. Transport coefficients in Lorentz plasmas with the power-law kappa-distribution

    SciTech Connect

    Jiulin, Du

    2013-09-15

    Transport coefficients in Lorentz plasma with the power-law κ-distribution are studied by means of using the transport equation and macroscopic laws of Lorentz plasma without magnetic field. Expressions of electric conductivity, thermoelectric coefficient, and thermal conductivity for the power-law κ-distribution are accurately derived. It is shown that these transport coefficients are significantly modified by the κ-parameter, and in the limit of the parameter κ→∞ they are reduced to the standard forms for a Maxwellian distribution.

  10. Time-dependent Kramers escape rate in overdamped system with power-law distribution

    NASA Astrophysics Data System (ADS)

    Zhou, Yanjun; Yin, Cangtao

    2016-05-01

    The probability distribution of Brownian particles moving in an overdamped complex system follows the generalized Smoluchowski equation, which can be rigorously proven that the exact time-dependent solution for this equation follows Tsallis form. Time-dependent escape rate in overdamped system with power-law distributions is then established based on the flux over population theory. The stationary state escape rate in overdamped system with power-law distribution which has been obtained before based on mean first passage time theory is recovered from time-dependent escape rate as time toward infinity.

  11. 1.38 MW peak power dual-loss modulated sub-nanosecond green laser with EO and graphene

    NASA Astrophysics Data System (ADS)

    Tang, Wenjing; Zhao, Jia; Yang, Kejian; Zhao, Shengzhi; Li, Guiqiu; Li, Dechun; Li, Tao; Qiao, Wenchao

    2016-12-01

    By simultaneously employing electro-optic (EO) modulator and Graphene saturable absorber (SA) in a dual-loss-modulated Q-switched and mode-locking (QML) Nd:Lu0.15Y0.85VO4/KTP green laser, the sub-nanosecond single mode-locking green laser is demonstrated with high peak power, low repetition rate and high stability. The monolayer and 3-layer graphene sheets grown by chemical vapor deposition (CVD) method were used as SAs in the experiment. When the pump power reached 10.72 W, the maximum peak power obtained from the doubly QML laser with EO and monolayer graphene-SA was 1.38 MW, corresponding to a pulse duration of 480 ps. The shortest pulse width of 340 ps was obtained with a 3-layer graphene-SA.

  12. Independent Orbiter Assessment (IOA): Analysis of the Electrical Power Distribution and Control Subsystem, Volume 2

    NASA Technical Reports Server (NTRS)

    Schmeckpeper, K. R.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list.

  13. Universal inverse power-law distribution for temperature and rainfall in the UK region

    NASA Astrophysics Data System (ADS)

    Selvam, A. M.

    2014-06-01

    Meteorological parameters, such as temperature, rainfall, pressure, etc., exhibit selfsimilar space-time fractal fluctuations generic to dynamical systems in nature such as fluid flows, spread of forest fires, earthquakes, etc. The power spectra of fractal fluctuations display inverse power-law form signifying long-range correlations. A general systems theory model predicts universal inverse power-law form incorporating the golden mean for the fractal fluctuations. The model predicted distribution was compared with observed distribution of fractal fluctuations of all size scales (small, large and extreme values) in the historic month-wise temperature (maximum and minimum) and total rainfall for the four stations Oxford, Armagh, Durham and Stornoway in the UK region, for data periods ranging from 92 years to 160 years. For each parameter, the two cumulative probability distributions, namely cmax and cmin starting from respectively maximum and minimum data value were used. The results of the study show that (i) temperature distributions (maximum and minimum) follow model predicted distribution except for Stornowy, minimum temperature cmin. (ii) Rainfall distribution for cmin follow model predicted distribution for all the four stations. (iii) Rainfall distribution for cmax follows model predicted distribution for the two stations Armagh and Stornoway. The present study suggests that fractal fluctuations result from the superimposition of eddy continuum fluctuations.

  14. Power law distribution in high frequency financial data? An econometric analysis

    NASA Astrophysics Data System (ADS)

    Todorova, Lora; Vogt, Bodo

    2011-11-01

    Power law distributions are very common in natural sciences. We analyze high frequency financial data from XETRA and the NYSE using maximum likelihood estimation and the Kolmogorov-Smirnov statistic to test whether the power law hypothesis holds also for these data. We find that the universality and scale invariance properties of the power law are violated. Furthermore, the returns of Daimler Chrysler and SAP traded simultaneously on both exchanges follow a power law at one exchange, but not at the other. These results raise some questions about the no-arbitrage condition. Finally, we find that an exponential function provides a better fit for the tails of the sample distributions than a power law function.

  15. Impact of Distributed Wind on Bulk Power System Operations in ISO-NE: Preprint

    SciTech Connect

    Brancucci Martinez-Anido, C.; Hodge, B. M.; Palchak, D.; Miettinen, J.

    2014-09-01

    The work presented in this paper aims to study the impact of a range of penetration levels of distributed wind on the operation of the electric power system at the transmission level. This paper presents a case study on the power system in Independent System Operator New England. It is analyzed using PLEXOS, a commercial power system simulation tool. The results show that increasing the integration of distributed wind reduces total variable electricity generation costs, coal- and gas-fired electricity generation, electricity imports, and CO2 emissions, and increases wind curtailment. The variability and uncertainty of wind power also increases the start-up and shutdown costs and ramping of most conventional power plants.

  16. Impact of Distributed Wind on Bulk Power System Operations in ISO-NE

    SciTech Connect

    Brancucci Martinez-Anido, Carlo; Hodge, Bri-Mathias; Palchak, David; Miettinen, Jari

    2014-11-13

    The work presented in this paper aims to study the impact of a range of penetration levels of distributed wind on the operation of the electric power system at the transmission level. This paper presents a case study on the power system in Independent System Operator New England. It is analyzed using PLEXOS, a commercial power system simulation tool. The results show that increasing the integration of distributed wind reduces total variable electricity generation costs, coal- and gas-fired electricity generation, electricity imports, and CO2 emissions, and increases wind curtailment. The variability and uncertainty of wind power also increases the start-up and shutdown costs and ramping of most conventional power plants.

  17. Drift Loss-Cone Distributions Electrons in the Jovian Synchrotron Zone from 06 and VIP4 Models

    NASA Technical Reports Server (NTRS)

    Wang, K.; Bolton, S. J.; Gulkis, S.; Levin, S. M.

    2000-01-01

    Relativistic electrons (10-50 MeV) play an important role to account for the observed synchrotron decimetric radiation in Jupiter's inner radiation belt (L < 4). A detailed knowledge of these electron distributions is required to understand the synchrotron emission observations and the associated on-going physical processes. In this paper, instead of assuming electrons drift along constant L-shell at the magnetic equator as many earlier studies adopted, we calculate the size of the theoretical drift-loss cone for relativistic electrons using both the O6 and VIP4 magnetic field models. Model maps of the synchrotron emission for specific electron distributions are shown for comparison.

  18. Space-based solar power generation using a distributed network of satellites and methods for efficient space power transmission

    NASA Astrophysics Data System (ADS)

    McLinko, Ryan M.; Sagar, Basant V.

    2009-12-01

    Space-based solar power (SSP) generation is being touted as a solution to our ever-increasing energy consumption and dependence on fossil fuels. Satellites in Earth's orbit can capture solar energy through photovoltaic cells and transmit that power to ground based stations. Solar cells in orbit are not hindered by weather, clouds, or night. The energy generated by this process is clean and pollution-free. Although the concept of space-based solar power was initially proposed nearly 40 years ago, the level of technology in photovoltaics, power transmission, materials, and efficient satellite design has finally reached a level of maturity that makes solar power from space a feasible prospect. Furthermore, new strategies in methods for solar energy acquisition and transmission can lead to simplifications in design, reductions in cost and reduced risk. This paper proposes using a distributed array of small satellites to collect power from the Sun, as compared to the more traditional SSP design that consists of one monolithic satellite. This concept mitigates some of SSP's most troublesome historic constraints, such as the requirement for heavy lift launch vehicles and the need for significant assembly in space. Instead, a larger number of smaller satellites designed to collect solar energy are launched independently. A high frequency beam will be used to aggregate collected power into a series of transmission antennas, which beam the energy to Earth's surface at a lower frequency. Due to the smaller power expectations of each satellite and the relatively short distance of travel from low earth orbit, such satellites can be designed with smaller arrays. The inter-satellite rectenna devices can also be smaller and lighter in weight. Our paper suggests how SSP satellites can be designed small enough to fit within ESPA standards and therefore use rideshare to achieve orbit. Alternatively, larger versions could be launched on Falcon 9s or on Falcon 1s with booster stages

  19. Enhanced magnetic domain relaxation frequency and low power losses in Zn2+ substituted manganese ferrites potential for high frequency applications

    NASA Astrophysics Data System (ADS)

    Praveena, K.; Chen, Hsiao-Wen; Liu, Hsiang-Lin; Sadhana, K.; Murthy, S. R.

    2016-12-01

    Nowadays electronic industries prerequisites magnetic materials, i.e., iron rich materials and their magnetic alloys. However, with the advent of high frequency applications, the standard techniques of reducing eddy current losses, using iron cores, were no longer efficient or cost effective. Current market trends of the switched mode power supplies industries required even low energy losses in power conversion with maintenance of adequate initial permeability. From the above point of view, in the present study we aimed at the production of Manganese-Zinc ferrites prepared via solution combustion method using mixture of fuels and achieved low loss, high saturation magnetization, high permeability, and high magnetic domain relaxation frequency. The as-synthesized Zn2+ substituted MnFe2O4 were characterized by X-ray diffractometer (XRD) and transmission electron microscopy (TEM). The fractions of Mn2+, Zn2+ and Fe2+ cations occupying tetrahedral sites along with Fe occupying octahedral sites within the unit cell of all ferrite samples were estimated by Raman scattering spectroscopy. The magnetic domain relaxation was investigated by inductance spectroscopy (IS) and the observed magnetic domain relaxation frequency (fr) was increased with the increase in grain size. The real and imaginary part of permeability (μ‧ and μ″) increased with frequency and showed a maximum above 100 MHz. This can be explained on the basis of spin rotation and domain wall motion. The saturation magnetization (Ms), remnant magnetization (Mr) and magneton number (μB) decreased gradually with increasing Zn2+ concentration. The decrease in the saturation magnetization was discussed with Yafet-Kittel (Y-K) model. The Zn2+ concentration increases the relative number of ferric ions on the A sites, reduces the A-B interactions. The frequency dependent total power losses decreased as the zinc concentration increased. At 1 MHz, the total power loss (Pt) changed from 358 mW/cm3 for x=0-165 mW/cm3

  20. Power Distribution at the Bottom of the Pyramid: Illumination through Affordable and Sustainable Solution of Gram Power

    NASA Astrophysics Data System (ADS)

    Pandey, Nisha; Sarswat, Prashant

    2016-03-01

    Energy plays a vital role in the socio -economic development, mainly due to the dependency of indispensable amenities on electricity. However, a matter of concern is developing country domestic power needs and inadequate supply. One of the cases is Indian subcontinent, where more than 50,000 villages still not have access to uninterrupted electric power. `Power theft' is a major challenge due to the lack of adequate energy supply and the financial constraints. Long distances, inaccurate and inflated electricity bills are the other issues lead to default on payments. Gram Power, a social enterprise, is providing a smart metering and affordable solution in areas where the extension of existing grid supply is economically not viable. India's first solar powered micro-grid (centralized array of solar panels) in Rajasthan was established by this initiative. The core innovation is a smart distribution technology that consists of smart meters with recharging facility and grid monitoring, to provide on-demand, theft-proof power through centralized servers with a pay-as-you-use schedule. The details of the changes, socio-economic transformation, and operational sustainability of such a community engagement model will be discussed in this study.

  1. How to implement decoy-state quantum key distribution for a satellite uplink with 50-dB channel loss

    SciTech Connect

    Meyer-Scott, Evan; Yan, Zhizhong; MacDonald, Allison; Bourgoin, Jean-Philippe; Huebel, Hannes; Jennewein, Thomas

    2011-12-15

    Quantum key distribution (QKD) takes advantage of fundamental properties of quantum physics to allow two distant parties to share a secret key; however, QKD is hampered by a distance limitation of a few hundred kilometers on Earth. The most immediate solution for global coverage is to use a satellite, which can receive separate QKD transmissions from two or more ground stations and act as a trusted node to link these ground stations. In this article we report on a system capable of performing QKD in the high loss regime expected in an uplink to a satellite using weak coherent pulses and decoy states. Such a scenario profits from the simplicity of its receiver payload, but has so far been considered to be infeasible due to very high transmission losses (40-50 dB). The high loss is overcome by implementing an innovative photon source and advanced timing analysis. Our system handles up to 57 dB photon loss in the infinite key limit, confirming the viability of the satellite uplink scenario. We emphasize that while this system was designed with a satellite uplink in mind, it could just as easily overcome high losses on any free space QKD link.

  2. 22 CFR 211.9 - Liability for loss damage or improper distribution of commodities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and other factors affecting its accuracy, or an explanation of why a scale was not used and how weight... specify how such losses occurred; (E) Obtain copies of port and/or ship records including scale weights... bill(s) of lading, (B) The related outturn or survey report(s), (C) Evidence showing the amount...

  3. Comprehensive evaluation of power grid projects' investment benefits under the reform of transmission and distribution price

    NASA Astrophysics Data System (ADS)

    Wang, Yongli; Wang, Gang; Zuo, Yi; Fan, Lisha; Ling, Yunpeng

    2017-03-01

    On March 15, 2015, the Central Office issued the "Opinions on Further Deepening the Reform of Electric Power System" (Zhong Fa No. 9). This policy marks the central government officially opened a new round of electricity reform. As a programmatic document under the new situation to comprehensively promote the reform of the power system, No. 9 document will be approved as a separate transmission and distribution of electricity prices, which is the first task of promoting the reform of the power system. Grid tariff reform is not only the transmission and distribution price of a separate approval, more of the grid company input-output relationship and many other aspects of deep-level adjustments. Under the background of the reform of the transmission and distribution price, the main factors affecting the input-output relationship, such as the main business, electricity pricing, and investment approval, financial accounting and so on, have changed significantly. The paper designed the comprehensive evaluation index system of power grid projects' investment benefits under the reform of transmission and distribution price to improve the investment efficiency of power grid projects after the power reform in China.

  4. Space station electrical power distribution analysis using a load flow approach

    NASA Technical Reports Server (NTRS)

    Emanuel, Ervin M.

    1987-01-01

    The space station's electrical power system will evolve and grow in a manner much similar to the present terrestrial electrical power system utilities. The initial baseline reference configuration will contain more than 50 nodes or busses, inverters, transformers, overcurrent protection devices, distribution lines, solar arrays, and/or solar dynamic power generating sources. The system is designed to manage and distribute 75 KW of power single phase or three phase at 20 KHz, and grow to a level of 300 KW steady state, and must be capable of operating at a peak of 450 KW for 5 to 10 min. In order to plan far into the future and keep pace with load growth, a load flow power system analysis approach must be developed and utilized. This method is a well known energy assessment and management tool that is widely used throughout the Electrical Power Utility Industry. The results of a comprehensive evaluation and assessment of an Electrical Distribution System Analysis Program (EDSA) is discussed. Its potential use as an analysis and design tool for the 20 KHz space station electrical power system is addressed.

  5. Automation in the Space Station module power management and distribution Breadboard

    NASA Technical Reports Server (NTRS)

    Walls, Bryan; Lollar, Louis F.

    1990-01-01

    The Space Station Module Power Management and Distribution (SSM/PMAD) Breadboard, located at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, models the power distribution within a Space Station Freedom Habitation or Laboratory module. Originally designed for 20 kHz ac power, the system is now being converted to high voltage dc power with power levels on a par with those expected for a space station module. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level process consists of fast, simple (from a computing standpoint) switchgear, capable of quickly safing the system. The next level consists of local load center processors called Lowest Level Processors (LLP's). These LLP's execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. The level above the LLP's contains a Communication and Algorithmic Controller (CAC) which coordinates communications with the highest level. Finally, at this highest level, three cooperating Artificial Intelligence (AI) systems manage load prioritization, load scheduling, load shedding, and fault recovery and management. The system provides an excellent venue for developing and examining advanced automation techniques. The current system and the plans for its future are examined.

  6. Quantitative estimation of farmland soil loss by wind-erosion using improved particle-size distribution comparison method (IPSDC)

    NASA Astrophysics Data System (ADS)

    Rende, Wang; Zhongling, Guo; Chunping, Chang; Dengpan, Xiao; Hongjun, Jiang

    2015-12-01

    The rapid and accurate estimation of soil loss by wind erosion still remains challenge. This study presents an improved scheme for estimating the soil loss by wind erosion of farmland. The method estimates the soil loss by wind erosion based on a comparison of the relative contents of erodible and non-erodible particles between the surface and sub-surface layers of the farmland ploughed layer after wind erosion. It is based on the features that the soil particle-size distribution of the sampling soil layer (approximately 2 cm) is relatively uniform, and that on the surface layer, wind erosion causes the relative numbers of erodible and non-erodible particles to decrease and increase, respectively. Estimations were performed using this method for the wind erosion periods (WEP) from Oct. of 2012 to May of 2013 and from Oct. of 2013 to April of 2014 and a large wind-erosion event (WEE) on May 3, 2014 in the Bashang area of Hebei Province. The results showed that the average soil loss of farmland by wind erosion from Oct. of 2012 to May of 2013 was 2852.14 g/m2 with an average depth of 0.21 cm, while soil loss by wind from Oct. of 2013 to April of 2014 was 1199.17 g/m2 with a mean depth of 0.08 cm. During the severe WEE on May 3, 2014, the average soil loss of farmland by wind erosion was 1299.19 g/m2 with an average depth of 0.10 cm. The soil loss by wind erosion of ploughed and raked fields (PRF) was approximately twice as large as that of oat-stubble fields (OSF). The improved method of particle-size distribution comparison (IPSDC) has several advantages. It can not only calculate the wind erosion amount, but also the wind deposition amount. Slight changes in the sampling thickness and in the particle diameter range of the non-erodible particles will not obviously influence the results. Furthermore, the method is convenient, rapid, simple to implement. It is suitable for estimating the soil loss or deposition by wind erosion of farmland with flat surfaces and high

  7. Intelligent Monitoring System With High Temperature Distributed Fiberoptic Sensor For Power Plant Combustion Processes

    SciTech Connect

    Kwang Y. Lee; Stuart S. Yin; Andre Boheman

    2005-12-26

    The objective of the proposed work is to develop an intelligent distributed fiber optical sensor system for real-time monitoring of high temperature in a boiler furnace in power plants. Of particular interest is the estimation of spatial and temporal distributions of high temperatures within a boiler furnace, which will be essential in assessing and controlling the mechanisms that form and remove pollutants at the source, such as NOx. The basic approach in developing the proposed sensor system is three fold: (1) development of high temperature distributed fiber optical sensor capable of measuring temperatures greater than 2000 C degree with spatial resolution of less than 1 cm; (2) development of distributed parameter system (DPS) models to map the three-dimensional (3D) temperature distribution for the furnace; and (3) development of an intelligent monitoring system for real-time monitoring of the 3D boiler temperature distribution. Under Task 1, we set up a dedicated high power, ultrafast laser system for fabricating in-fiber gratings in harsh environment optical fibers, successfully fabricated gratings in single crystal sapphire fibers by the high power laser system, and developed highly sensitive long period gratings (lpg) by electric arc. Under Task 2, relevant mathematical modeling studies of NOx formation in practical combustors. Studies show that in boiler systems with no swirl, the distributed temperature sensor may provide information sufficient to predict trends of NOx at the boiler exit. Under Task 3, we investigate a mathematical approach to extrapolation of the temperature distribution within a power plant boiler facility, using a combination of a modified neural network architecture and semigroup theory. The 3D temperature data is furnished by the Penn State Energy Institute using FLUENT. Given a set of empirical data with no analytic expression, we first develop an analytic description and then extend that model along a single axis. Extrapolation

  8. Analysis of the working process and mechanical losses in a Stirling engine for a solar power unit

    SciTech Connect

    Makhkamov, K.K.; Ingham, D.B.

    1999-05-01

    In this paper a second level mathematical model for the computational simulation of the working process of a 1-kW Stirling engine has been used and the results obtained are presented. The internal circuit of the engine in the calculation scheme was divided into five chambers, namely, the expansion space, heater, regenerator, cooler and the compression space, and the governing system of ordinary differential equations for the energy and mass conservation were solved in each chamber by Euler`s method. In addition, mechanical losses in the construction of the engine have been determined and the computational results show that the mechanical losses for this particular design of the Stirling engine may be up to 50% of the indicated power of the engine.

  9. Recovery of inter-row shading losses using differential power-processing submodule DC–DC converters

    DOE PAGES

    Doubleday, Kate; Choi, Beomseok; Maksimovic, Dragan; ...

    2016-06-17

    Large commercial photovoltaic (PV) systems can experience regular and predictable energy loss due to both inter-row shading and reduced diffuse irradiance in tightly spaced arrays. This article investigates the advantages of replacing bypass diodes with submodule-integrated DC-DC converters (subMICs) to mitigate these losses. Yearly simulations of commercial-scale PV systems were conducted considering a range of row-to-row pitches. In the limit case of array spacing (unity ground coverage), subMICs can confer a 7% increase in annual energy output and peak energy density (kW h/m2). Simulation results are based on efficiency assumptions experimentally confirmed by prototype submodule differential power-processing converters.

  10. A compact and low-loss 1×8 optical power splitter using silica-based PLC on quartz substrate

    NASA Astrophysics Data System (ADS)

    Wang, Liangliang; An, Junming; Wu, Yuanda; Zhang, Jiashun; Wang, Yue; Li, Jianguang; Wang, Hongjie; Zhang, Xiaoguang; Pan, Pan; Zhang, Liyao; Dai, Hongqing; Liu, Ruidan; Zhong, Fei; Zha, Qiang; Hu, Xiongwei; Zhao, Degang

    2014-02-01

    In this paper, a compact, low-loss and good-uniformity 1×8 optical power splitter with new Y-branch structure is demonstrated using silica-based PLC technology on quartz substrate. Broadening waveguide and transition waveguide of the new Y-branch are optimized by using 3D BPM. The measurement results show that the insertion loss (IL) and the uniformity (UNIF) of the splitters are less than 9.5 dB and 0.35 dB, respectively, in the wavelength range from 1.26 μm to 1.65 μm, and the total product ratio of premium grade in a whole 6 in. wafer is more than 95%. The results mean that our technology completely satisfies the need of mass manufacture.

  11. Recovery of inter-row shading losses using differential power-processing submodule DC–DC converters

    SciTech Connect

    Doubleday, Kate; Choi, Beomseok; Maksimovic, Dragan; Deline, Chris; Olalla, Carlos

    2016-06-17

    Large commercial photovoltaic (PV) systems can experience regular and predictable energy loss due to both inter-row shading and reduced diffuse irradiance in tightly spaced arrays. This article investigates the advantages of replacing bypass diodes with submodule-integrated DC-DC converters (subMICs) to mitigate these losses. Yearly simulations of commercial-scale PV systems were conducted considering a range of row-to-row pitches. In the limit case of array spacing (unity ground coverage), subMICs can confer a 7% increase in annual energy output and peak energy density (kW h/m2). Simulation results are based on efficiency assumptions experimentally confirmed by prototype submodule differential power-processing converters.

  12. Hybrid power system intelligent operation and protection involving distributed architectures and pulsed loads

    NASA Astrophysics Data System (ADS)

    Mohamed, Ahmed

    Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available

  13. Arrayed narrow linewidth erbium-doped waveguide-distributed feedback lasers on an ultra-low-loss silicon-nitride platform.

    PubMed

    Belt, Michael; Huffman, Taran; Davenport, Michael L; Li, Wenzao; Barton, Jonathon S; Blumenthal, Daniel J

    2013-11-15

    We demonstrate an array of erbium-doped waveguide-distributed feedback lasers on an ultra-low-loss Si(3)N(4) platform. Sidewall gratings providing the lasing feedback are defined in the silicon-nitride layer using 248 nm stepper lithography, while the gain is provided by a reactive co-sputtered erbium-doped aluminum-oxide layer. We observe lasing output over a 12 nm wavelength range (1531-1543 nm) from the array of five separate lasers. Output powers of 8 μW and lasing linewidths of 501 kHz are obtained. Single-mode operation is confirmed, with side-mode suppression ratios over 35 dB for all designs.

  14. Ion Distribution And Electronic Stopping Power For Au ions In Silicon Carbide

    SciTech Connect

    Jin, Ke; Zhang, Yanwen; Xue, Haizhou; Zhu, Zihua; Weber, William J.

    2013-07-15

    Accurate knowledge of ion distribution and electronic stopping power for heavy ions in light targets is highly desired due to the large errors in prediction by the widely used Stopping and Range of Ions in Matter (SRIM) code. In this study, Rutherford backscattering spectrometry (RBS)and secondary ion mass spectrometry (SIMS) are used as complementary techniques to determine the distribution of Au ions in SiC with energie sfrom 700 keV to 15 MeV. In addition, asingle ion technique with an improved data analysis procedure is applied to measure the electronic stopping power for Au ions in SiC with energies up to ~70 keV/nucleon. Large overestimation of the electronic stopping power is found by SRIM prediction in the low energy regime up to ~50 keV/nucleon. The stopping power data and the ion ranges are crosschecked with each other and a good agreement is achieved.

  15. The in vivo distribution of brain tissue loss in Richardson's syndrome and PSP-parkinsonism: a VBM-DARTEL study.

    PubMed

    Agosta, Federica; Kostić, Vladimir S; Galantucci, Sebastiano; Mesaros, Sarlota; Svetel, Marina; Pagani, Elisabetta; Stefanova, Elka; Filippi, Massimo

    2010-08-01

    In this study, we wished to test, using magnetic resonance imaging and voxel-based morphometry (VBM), whether specific cortical and subcortical patterns of brain grey (GM) and white matter (WM) tissue loss can be detected in patients with Richardson's syndrome (PSP-RS) and progressive supranuclear palsy-parkinsonism (PSP-P), and possibly account for their clinical heterogeneity. Twenty patients with PSP, classified as PSP-RS (10 patients) or PSP-P (10 patients), and 24 healthy controls were studied. The Statistical Parametric Mapping (SPM5) and the Diffeomorphic Anatomical Registration using Exponentiated Lie algebra method were used to perform a VBM analysis. Compared with controls, both patient groups showed GM loss in the central midbrain, cerebellar lobes, caudate nuclei, frontotemporal cortices and right hippocampus. WM loss was detected in both conditions in the midbrain, left superior cerebellar peduncle, internal capsulae, and left premotor and bilateral prefrontal regions. Compared with PSP-P, patients with PSP-RS showed additional regions of GM loss in the midbrain, left cerebellar lobe and dentate nuclei. PSP-RS was also associated with a more severe WM loss in the midbrain, internal capsulae, and orbitofrontal, prefrontal and precentral/premotor regions, bilaterally. Patients with PSP-P showed a more pronounced GM loss only in the frontal cortex, bilaterally. This study shows that, albeit the overall pattern of brain atrophy associated with PSP appears remarkably consistent across the spectrum of clinical features recorded in life, major anatomical differences between these two conditions do exist. Such a different topographical distribution of tissue damage may account for the clinical differences between PSP-RS and PSP-P.

  16. Intensity and absorbed-power distribution in a cylindrical solar-pumped dye laser

    NASA Technical Reports Server (NTRS)

    Williams, M. D.

    1984-01-01

    The internal intensity and absorbed-power distribution of a simplified hypothetical dye laser of cylindrical geometry is calculated. Total absorbed power is also calculated and compared with laboratory measurements of lasing-threshold energy deposition in a dye cell to determine the suitability of solar radiation as a pump source or, alternatively, what modifications, if any, are necessary to the hypothetical system for solar pumping.

  17. Enhanced Recovery Utilizing Variable Frequency Drives and a Distributed Power System

    SciTech Connect

    Randy Peden; Sanjiv Shah

    2005-07-26

    This report describes complete results of the project entitled ''Enhanced Recovery Utilizing Variable Frequency Drives and a Distributed Power System''. This demonstration project was initiated in July 2003 and completed in March 2005. The objective of the project was to develop an integrated power production/variable frequency drive system that could easily be deployed in the oil field that would increase production and decrease operating costs. This report describes all the activities occurred and documents results of the demonstration.

  18. Power conversion distribution system using a resonant high-frequency AC link

    NASA Technical Reports Server (NTRS)

    Sood, P. K.; Lipo, T. A.

    1986-01-01

    Static power conversion systems based on a resonant high frequency (HF) link offers a significant reduction in the size and weight of the equipment over that achieved with conventional approaches, especially when multiple sources and loads are to be integrated. A faster system response and absence of audible noise are the other principal characteristics of such systems. A conversion configuration based on a HF link which is suitable for applications requiring distributed power is proposed.

  19. Advanced electrical power, distribution and control for the Space Transportation System

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.; Brandhorst, Henry W., Jr.

    1990-01-01

    High frequency power distribution and management is a technology ready state of development. As such, a system employs the fewest power conversion steps, and employs zero current switching for those steps. It results in the most efficiency, and lowest total parts system count when equivalent systems are compared. The operating voltage and frequency are application specific trade off parameters. However, a 20 kHz Hertz system is suitable for wide range systems.

  20. Giant third-order nonlinearity from low-loss electrochemical graphene oxide film with a high power stability

    NASA Astrophysics Data System (ADS)

    Ren, Jun; Zheng, Xiaorui; Tian, Zhiming; Li, Dan; Wang, Pu; Jia, Baohua

    2016-11-01

    Giant third-order nonlinear absorption and refraction of electrochemical graphene oxide (EGO) film were investigated in the femtosecond regime using the single beam Z-scan technique. The excellent chemical stability of the EGO film under high-power illumination up to 400 mJ/cm2 is demonstrated, which can be attributed to the low oxidation degree revealed by the optical and Raman spectroscopies. High and broadband linear transmission over 70% has been observed from the visible to the infrared range. The low-loss EGO film with giant third-order nonlinearity, excellent chemical stability, large-scale preparation and flexible integration has a great potential for high-power nonlinear optical applications.