Science.gov

Sample records for power system loads

  1. Automated load management for spacecraft power systems

    NASA Technical Reports Server (NTRS)

    Lollar, Louis F.

    1987-01-01

    An account is given of the results of a study undertaken by NASA's Marshall Space Flight Center to design and implement the load management techniques for autonomous spacecraft power systems, such as the Autonomously Managed Power System Test Facility. Attention is given to four load-management criteria, which encompass power bus balancing on multichannel power systems, energy balancing in such systems, power quality matching of loads to buses, and contingency load shedding/adding. Full implementation of these criteria calls for the addition of a second power channel.

  2. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1989-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  3. Electric power distribution and load transfer system

    NASA Technical Reports Server (NTRS)

    Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)

    1987-01-01

    A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.

  4. Power quality load management for large spacecraft electrical power systems

    NASA Technical Reports Server (NTRS)

    Lollar, Louis F.

    1988-01-01

    In December, 1986, a Center Director's Discretionary Fund (CDDF) proposal was granted to study power system control techniques in large space electrical power systems. Presented are the accomplishments in the area of power system control by power quality load management. In addition, information concerning the distortion problems in a 20 kHz ac power system is presented.

  5. Load Modeling and Calibration Techniques for Power System Studies

    SciTech Connect

    Chassin, Forrest S.; Mayhorn, Ebony T.; Elizondo, Marcelo A.; Lu, Shuai

    2011-09-23

    Load modeling is the most uncertain area in power system simulations. Having an accurate load model is important for power system planning and operation. Here, a review of load modeling and calibration techniques is given. This paper is not comprehensive, but covers some of the techniques most commonly found in the literature. The advantages and disadvantages of each technique are outlined.

  6. Short-term load forecasting of power system

    NASA Astrophysics Data System (ADS)

    Xu, Xiaobin

    2017-05-01

    In order to ensure the scientific nature of optimization about power system, it is necessary to improve the load forecasting accuracy. Power system load forecasting is based on accurate statistical data and survey data, starting from the history and current situation of electricity consumption, with a scientific method to predict the future development trend of power load and change the law of science. Short-term load forecasting is the basis of power system operation and analysis, which is of great significance to unit combination, economic dispatch and safety check. Therefore, the load forecasting of the power system is explained in detail in this paper. First, we use the data from 2012 to 2014 to establish the partial least squares model to regression analysis the relationship between daily maximum load, daily minimum load, daily average load and each meteorological factor, and select the highest peak by observing the regression coefficient histogram Day maximum temperature, daily minimum temperature and daily average temperature as the meteorological factors to improve the accuracy of load forecasting indicators. Secondly, in the case of uncertain climate impact, we use the time series model to predict the load data for 2015, respectively, the 2009-2014 load data were sorted out, through the previous six years of the data to forecast the data for this time in 2015. The criterion for the accuracy of the prediction is the average of the standard deviations for the prediction results and average load for the previous six years. Finally, considering the climate effect, we use the BP neural network model to predict the data in 2015, and optimize the forecast results on the basis of the time series model.

  7. Load Frequency Control in Power System with Distributed Generation

    NASA Astrophysics Data System (ADS)

    Yukita, Kazuto; Ota, Takuya; Fujimoto, Koji; Goto, Yasuyuki; Ichiyanagi, Katuhiro

    This paper proposes a method to improve the load frequency control in a power system with distributed generation (DG). DG is assumed to include photovoltaic generation, wind power generation, fuel cells and etc. In this paper, a simulation is performed using a microgrid model or island model that is composed of a storage system with either wind power generation or photovoltaic generation system as the DG. The effectiveness of load frequency control (LFC) using a storage system is examined using a power transmission simulator. The model for the experiment has been composed of inverter, battery, synchronous generator and load. Using this model, the comparison examination was done in respect of output setting control and the case in which the PI control was used. As a result, when the output set-point control using power demand estimation method is executed, the control characteristic is very excellent.

  8. Power system very short-term load prediction

    SciTech Connect

    Trudnowski, D.J.; Johnson, J.M.; Whitney, P.

    1997-02-01

    A fundamental objective of a power-system operating and control scheme is to maintain a match between the system`s overall real-power load and generation. To accurately maintain this match, modern energy management systems require estimates of the future total system load. Several strategies and tools are available for estimating system load. Nearly all of these estimate the future load in 1-hour steps over several hours (or time frames very close to this). While hourly load estimates are very useful for many operation and control decisions, more accurate estimates at closer intervals would also be valuable. This is especially true for emerging Area Generation Control (AGC) strategies such as look-ahead AGC. For these short-term estimation applications, future load estimates out to several minutes at intervals of 1 to 5 minutes are required. The currently emerging operation and control strategies being developed by the BPA are dependent on accurate very short-term load estimates. To meet this need, the BPA commissioned the Pacific Northwest National Laboratory (PNNL) and Montana Tech (an affiliate of the University of Montana) to develop an accurate load prediction algorithm and computer codes that automatically update and can reliably perform in a closed-loop controller for the BPA system. The requirements include accurate load estimation in 5-minute steps out to 2 hours. This report presents the results of this effort and includes: a methodology and algorithms for short-term load prediction that incorporates information from a general hourly forecaster; specific algorithm parameters for implementing the predictor in the BPA system; performance and sensitivity studies of the algorithms on BPA-supplied data; an algorithm for filtering power system load samples as a precursor to inputting into the predictor; and FORTRAN 77 subroutines for implementing the algorithms.

  9. Load Frequency Control of AC Microgrid Interconnected Thermal Power System

    NASA Astrophysics Data System (ADS)

    Lal, Deepak Kumar; Barisal, Ajit Kumar

    2017-08-01

    In this paper, a microgrid (MG) power generation system is interconnected with a single area reheat thermal power system for load frequency control study. A new meta-heuristic optimization algorithm i.e. Moth-Flame Optimization (MFO) algorithm is applied to evaluate optimal gains of the fuzzy based proportional, integral and derivative (PID) controllers. The system dynamic performance is studied by comparing the results with MFO optimized classical PI/PID controllers. Also the system performance is investigated with fuzzy PID controller optimized by recently developed grey wolf optimizer (GWO) algorithm, which has proven its superiority over other previously developed algorithm in many interconnected power systems.

  10. Reliability Constrained Priority Load Shedding for Aerospace Power System Automation

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Zhu, Jizhong; Kaddah, Sahar S.; Dolce, James L. (Technical Monitor)

    2000-01-01

    The need for improving load shedding on board the space station is one of the goals of aerospace power system automation. To accelerate the optimum load-shedding functions, several constraints must be involved. These constraints include congestion margin determined by weighted probability contingency, component/system reliability index, generation rescheduling. The impact of different faults and indices for computing reliability were defined before optimization. The optimum load schedule is done based on priority, value and location of loads. An optimization strategy capable of handling discrete decision making, such as Everett optimization, is proposed. We extended Everett method to handle expected congestion margin and reliability index as constraints. To make it effective for real time load dispatch process, a rule-based scheme is presented in the optimization method. It assists in selecting which feeder load to be shed, the location of the load, the value, priority of the load and cost benefit analysis of the load profile is included in the scheme. The scheme is tested using a benchmark NASA system consisting of generators, loads and network.

  11. 46 CFR 112.15-10 - Loads on systems without a temporary emergency power source.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Loads on systems without a temporary emergency power...) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Loads § 112.15-10 Loads on systems without a temporary emergency power source. If there is no temporary emergency power source, the loads...

  12. 46 CFR 112.15-10 - Loads on systems without a temporary emergency power source.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Loads on systems without a temporary emergency power...) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Loads § 112.15-10 Loads on systems without a temporary emergency power source. If there is no temporary emergency power source, the loads...

  13. 46 CFR 112.15-10 - Loads on systems without a temporary emergency power source.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Loads on systems without a temporary emergency power...) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Loads § 112.15-10 Loads on systems without a temporary emergency power source. If there is no temporary emergency power source, the loads...

  14. 46 CFR 112.15-10 - Loads on systems without a temporary emergency power source.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Loads on systems without a temporary emergency power...) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Loads § 112.15-10 Loads on systems without a temporary emergency power source. If there is no temporary emergency power source, the loads...

  15. 46 CFR 112.15-10 - Loads on systems without a temporary emergency power source.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loads on systems without a temporary emergency power...) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Emergency Loads § 112.15-10 Loads on systems without a temporary emergency power source. If there is no temporary emergency power source, the loads...

  16. Improvement of Unbalanced Load Flow Program for Large Power Systems

    NASA Astrophysics Data System (ADS)

    Imai, Shinichi; Suzuki, Haruhiko; Iba, Kenji; Fujiwara, Shuhei

    The idea of unbalanced power flow calculation was proposed many years ago. At that time, however, the needs for such techniques was not an argent issue. But modern power system networks are comprised of long untransposed transmission lines. Therefore, for some kind of analysis, it is now almost impossible to treat a system as though it were a symmetrical network. The aims of most previous studies were oriented to solve voltage/current imbalance in local or small system because local imbalance was a serious concern. This is still an important issue, but more recently our needs have become concentrated on practical bulk power systems, since principal EHV lines are entirely untransposed. Following such a background, we have developed a practical unbalanced load flow program. This program was developed for steady state analysis of large scale of practical networks under many possible unbalanced conditions.

  17. Optimal power flow calculation for power system with UPFC considering load rate equalization

    NASA Astrophysics Data System (ADS)

    Liu, Jiankun; Chen, Jing; Zhang, Qingsong

    2017-06-01

    Unified power flow controller (UPFC) device can change system electrical quantity (such as voltage, impedance, phase angle, etc.) rapidly and flexibly under the premise of maintain security, stability and reliability of power system, thus can improve the transmission power and transmission line utilization, so as to enhance the power supply capacity of the power grid. Based on a thorough study of the steady-state model of UPFC, taking load rate equalization as objective function, the optimal power flow model is established with UPFC, and simplified interior point method is used to solve it. Finally, optimal power flow of 24 continuous sections actual data is calculated on a typical day of Nanjing network. The results show that the optimal power flow calculation with UPFC can optimize the load rate equalization on the basis of eliminating line overload, improving the voltage level of local power network.

  18. Coordination of Economic Load Dispatch and Load Frequency Control for Interconnected Power System

    NASA Astrophysics Data System (ADS)

    Shankar, R.; Chatterjee, K.; Chatterjee, T. K.

    2015-03-01

    This paper deals with the coordination of economic load dispatch and load frequency control concepts of the interconnected power system. The total change in the particular control area is shared by each unit according to their participation factor obtained from the calculation of the economic load dispatch. In this work, two control areas are considered, the first control area contains the combination of hydro, thermal and gas generating unit and in the second control area, it contains the combination of the thermal and hydro generating units. Integral controller is used for secondary controller for load frequency control mechanism. A digital simulation is used in conjunction with the genetic algorithm (GA) technique to determine the optimum parameters of the individual gain of integral controller. Three different types of performance indices are considered to measure the appropriateness of the proposed controller. The optimum values of the gains improve the dynamic performance of the controller and reduce the overshoot and maximum frequency deviation and net tie-line power flow deviation error for a particular load change. To show the effectiveness of the proposed controller, simulation result is shown in result and discussion section.

  19. A robust decentralized load frequency controller for interconnected power systems.

    PubMed

    Dong, Lili; Zhang, Yao; Gao, Zhiqiang

    2012-05-01

    A novel design of a robust decentralized load frequency control (LFC) algorithm is proposed for an inter-connected three-area power system, for the purpose of regulating area control error (ACE) in the presence of system uncertainties and external disturbances. The design is based on the concept of active disturbance rejection control (ADRC). Estimating and mitigating the total effect of various uncertainties in real time, ADRC is particularly effective against a wide range of parameter variations, model uncertainties, and large disturbances. Furthermore, with only two tuning parameters, the controller provides a simple and easy-to-use solution to complex engineering problems in practice. Here, an ADRC-based LFC solution is developed for systems with turbines of various types, such as non-reheat, reheat, and hydraulic. The simulation results verified the effectiveness of the ADRC, in comparison with an existing PI-type controller tuned via genetic algorithm linear matrix inequalities (GALMIs). The comparison results show the superiority of the proposed solution. Moreover, the stability and robustness of the closed-loop system is studied using frequency-domain analysis.

  20. Short term load forecasting of Taiwan power system using a knowledge-based expert system

    SciTech Connect

    Ho, K.L.; Hsu, Y.Y.; Chen, C.F.; Lee, T.E. . Dept. of Electrical Engineering); Liang, C.C.; Lai, T.S.; Chen, K.K. )

    1990-11-01

    A knowledge-based expert system is proposed for the short term load forecasting of Taiwan power system. The developed expert system, which was implemented on a personal computer, was written in PROLOG using a 5-year data base. To benefit from the expert knowledge and experience of the system operator, eleven different load shapes, each with different means of load calculations, are established. With these load shapes at hand, some peculiar load characteristics pertaining to Taiwan Power Company can be taken into account. The special load types considered by the expert system include the extremely low load levels during the week of the Chinese New Year, the special load characteristics of the days following a tropical storm or a typhoon, the partial shutdown of certain factories on Saturdays, and the special event caused by a holiday on Friday or on Tuesday, etc. A characteristic feature of the proposed knowledge-based expert system is that it is easy to add new information and new rules to the knowledge base. To illustrate the effectiveness of the presented expert system, short-term load forecasting is performed on Taiwan power system by using both the developed algorithm and the conventional Box-Jenkins statistical method. It is found that a mean absolute error of 2.52% for a year is achieved by the expert system approach as compared to an error of 3.86% by the statistical method.

  1. Limitations of power conversion systems under transient loads and impact on the pulsed tokamak power reactor

    NASA Astrophysics Data System (ADS)

    Sager, G. T.; Wong, C. P. C.; Kapich, D. D.; McDonald, C. F.; Schleicher, R. W.

    1993-11-01

    The impact of cyclic loading of the power conversion system of a helium-cooled, pulsed tokamak power plant is assessed. Design limits of key components of heat transport systems employing Rankine and Brayton thermodynamic cycles are quantified based on experience in gas-cooled fission reactor design and operation. Cyclic loads due to pulsed tokamak operation are estimated. Expected performance of the steam generator is shown to be incompatible with pulsed tokamak operation without load leveling thermal energy storage. The close cycle gas turbine is evaluated qualitatively based on performance of existing industrial and aeroderivative gas turbines. Advances in key technologies which significantly improve prospects for operation with tokamak fusion plants are reviewed.

  2. Limitations of power conversion systems under transient loads and impact on the pulsed tokamak power reactor

    SciTech Connect

    Sager, G.T.; Wong, C.P.C.; Kapich, D.D.; McDonald, C.F.; Schleicher, R.W.

    1993-11-01

    The impact of cyclic loading of the power conversion system of a helium-cooled, pulsed tokamak power plant is assessed. Design limits of key components of heat transport systems employing Rankie and Brayton thermodynamic cycles are quantified based on experience in gas-cooled fission reactor design and operation. Cyclic loads due to pulsed tokamak operation are estimated. Expected performance of the steam generator is shown to be incompatible with pulsed tokamak operation without load leveling thermal energy storage. The close cycle gas turbine is evaluated qualitatively based on performance of existing industrial and aeroderivative gas turbines. Advances in key technologies which significantly improve prospects for operation with tokamak fusion plants are reviewed.

  3. Loss of Load Probability Calculation for West Java Power System with Nuclear Power Plant Scenario

    NASA Astrophysics Data System (ADS)

    Azizah, I. D.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.; Shafii, M. A.

    2017-03-01

    Loss of Load Probability (LOLP) index showing the quality and performance of an electrical system. LOLP value is affected by load growth, the load duration curve, forced outage rate of the plant, number and capacity of generating units. This reliability index calculation begins with load forecasting to 2018 using multiple regression method. Scenario 1 with compositions of conventional plants produce the largest LOLP in 2017 amounted to 71.609 days / year. While the best reliability index generated in scenario 2 with the NPP amounted to 6.941 days / year in 2015. Improved reliability of systems using nuclear power more efficiently when compared to conventional plants because it also has advantages such as emission-free, inexpensive fuel costs, as well as high level of plant availability.

  4. Short-Term Forecasting of Loads and Wind Power for Latvian Power System: Accuracy and Capacity of the Developed Tools

    NASA Astrophysics Data System (ADS)

    Radziukynas, V.; Klementavičius, A.

    2016-04-01

    The paper analyses the performance results of the recently developed short-term forecasting suit for the Latvian power system. The system load and wind power are forecasted using ANN and ARIMA models, respectively, and the forecasting accuracy is evaluated in terms of errors, mean absolute errors and mean absolute percentage errors. The investigation of influence of additional input variables on load forecasting errors is performed. The interplay of hourly loads and wind power forecasting errors is also evaluated for the Latvian power system with historical loads (the year 2011) and planned wind power capacities (the year 2023).

  5. Service Oriented Architectural Model for Load Flow Analysis in Power Systems

    NASA Astrophysics Data System (ADS)

    Muthu, Balasingh Moses; Veilumuthu, Ramachandran; Ponnusamy, Lakshmi

    2011-07-01

    The main objective of this paper is to develop the Service Oriented Architectural (SOA) Model for representation of power systems, especially of computing load flow analysis of large interconnected power systems. The proposed SOA model has three elements namely load flow service provider, power systems registry and client. The exchange of data using XML makes the power system services standardized and adaptable. The load flow service is provided by the service provider, which is published in power systems registry for enabling universal visibility and access to the service. The message oriented style of SOA using Simple Object Access Protocol (SOAP) makes the service provider and the power systems client to exist in a loosely coupled environment. This proposed model, portraits the load flow services as Web services in service oriented environment. To suit the power system industry needs, it easily integrates with the Web applications which enables faster power system operations.

  6. 77 FR 70484 - Preoperational Testing of Onsite Electric Power Systems To Verify Proper Load Group Assignments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... encompass preoperational testing of electrical power systems used to meet current Station Blackout... COMMISSION Preoperational Testing of Onsite Electric Power Systems To Verify Proper Load Group Assignments, Electrical Separation, and Redundancy AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory...

  7. Fault-tolerant adaptive control for load-following in static space nuclear power systems

    NASA Technical Reports Server (NTRS)

    Parlos, Alexander G.; Onbasioglu, Fetiye O.; Peddicord, Kenneth L.; Metzger, John D.

    1992-01-01

    The possible use of a dual-loop model-based adaptive control system for load following in static space nuclear power systems is investigated. The proposed approach has thus far been applied only to a thermoelectric space nuclear power system but is equally applicable to other static space nuclear power systems such as thermionic systems.

  8. Fault-tolerant adaptive control for load-following in static space nuclear power systems

    NASA Technical Reports Server (NTRS)

    Parlos, Alexander G.; Onbasioglu, Fetiye O.; Peddicord, Kenneth L.; Metzger, John D.

    1992-01-01

    The possible use of a dual-loop model-based adaptive control system for load following in static space nuclear power systems is investigated. The proposed approach has thus far been applied only to a thermoelectric space nuclear power system but is equally applicable to other static space nuclear power systems such as thermionic systems.

  9. An adaptive load-following control system for a space nuclear power system

    NASA Astrophysics Data System (ADS)

    Metzger, John D.; El-Genk, Mohamed S.

    An adaptive load-following control system is proposed for a space nuclear power system. The conceptual design of the SP-100 space nuclear power system proposes operating the nuclear reactor at a base thermal power and accommodating changes in the electrical power demand with a shunt regulator. It is necessary to increase the reactor thermal power if the payload electrical demand exceeds the peak system electrical output for the associated reactor power. When it is necessary to change the nuclear reactor power to meet a change in the power demand, the power ascension or descension must be accomplished in a predetermined manner to avoid thermal stresses in the system and to achieve the desired reactor period. The load-following control system described has the ability to adapt to changes in the system and to changes in the satellite environment. The application is proposed of the model reference adaptive control (MRAC). The adaptive control system has the ability to control the dynamic response of nonlinear systems. Three basic subsets of adaptive control are: (1) gain scheduling, (2) self-tuning regulators, and (3) model reference adaptive control.

  10. The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system

    NASA Technical Reports Server (NTRS)

    Leskovich, R. Thomas; Hansen, Irving G.

    1989-01-01

    The Space Station Freedom power distribution system, which consists of dual redundant 20-kHz, 440-V RMS, single-phase power systems, is discussed. The effect of a typical space station nonlinear load on the measurement of RMS current and voltage at various points in the space station power system has been investigated using the Electromagnetic Transients Program (EMTP). The load current distortion at the user interface, its effect on the distribution system, and its relationship to power factor have been studied. Modeling results are compared to test data. The differences under nonlinear loading are evaluated and presented as a measure of distribution voltage distortion and current measurement accuracy.

  11. Systems and methods for providing power to a load based upon a control strategy

    DOEpatents

    Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

    2013-12-24

    Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

  12. Self-regulating control of parasitic loads in a fuel cell power system

    NASA Technical Reports Server (NTRS)

    Vasquez, Arturo (Inventor)

    2011-01-01

    A fuel cell power system comprises an internal or self-regulating control of a system or device requiring a parasitic load. The internal or self-regulating control utilizes certain components and an interconnection scheme to produce a desirable, variable voltage potential (i.e., power) to a system or device requiring parasitic load in response to varying operating conditions or requirements of an external load that is connected to a primary fuel cell stack of the system. Other embodiments comprise a method of designing such a self-regulated control scheme and a method of operating such a fuel cell power system.

  13. Power Sharing Control between Load-Side Inverters in DC Microgrid for Super High Quality Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Kakigano, Hiroaki; Nada, Kaho; Miura, Yushi; Ise, Toshifumi; Uchida, Ryohei

    DC microgrid is a novel power system using dc distribution in order to provide a super high quality electric power. The dc distribution system is suitable for dc output type distributed generations such as photovoltaic and fuel cells, and energy storages such as batteries and electric double layer capacitors. Power is distributed through dc distribution line and converted to required ac or dc voltage by converters placed near loads. Load-side single phase inverters are connected through transformers in order to share active and reactive power. In this paper, a power sharing control scheme was proposed, and the power sharing characteristics were demonstrated by experimental results.

  14. Load characteristics of wireless power transfer system with different resonant types and resonator numbers

    NASA Astrophysics Data System (ADS)

    Zhang, Yiming; Zhao, Zhengming; Chen, Kainan; Fan, Jun

    2017-05-01

    Wireless Power Transfer (WPT) has been the research focus and applied in many fields. Normally power is transferred wirelessly to charge the battery, which requires specific load characteristics. The load characteristics are essential for the design and operation of the WPT system. This paper investigates the load characteristics of the WPT system with different resonant types and resonator numbers. It is found that in a WPT system with series or LCL resonance under a constant voltage source, the load characteristic is determined by the number of inductors. Even number of inductors results in a constant current characteristic and odd number constant voltage characteristic. Calculations, simulations, and experiments verify the analysis.

  15. Electronic system for high power load control. [solar arrays

    NASA Technical Reports Server (NTRS)

    Miller, E. L. (Inventor)

    1980-01-01

    Parallel current paths are divided into two groups, with control devices in the current paths of one group each having a current limiting resistor, and the control devices in the other group each having no limiting resistor, so that when the control devices of the second group are turned fully on, a short circuit is achieved by the arrangement of parallel current paths. Separate but coordinated control signals are provided to turn on the control devices of the first group and increase their conduction toward saturation as a function of control input, and when fully on, or shortly before, to turn on the control devices of the second group and increase their conduction toward saturation as a function of the control input as that input continues to increase. Electronic means may be used to generate signals. The system may be used for 1-V characteristic measurements of solar arrays as well as for other load control purposes.

  16. Optimization of hybrid power system composed of SMES and flywheel MG for large pulsed load

    NASA Astrophysics Data System (ADS)

    Niiyama, K.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2008-09-01

    A superconducting magnetic storage system (SMES) has some advantages such as rapid large power response and high storage efficiency which are superior to other energy storage systems. A flywheel motor generator (FWMG) has large scaled capacity and high reliability, and hence is broadly utilized for a large pulsed load, while it has comparatively low storage efficiency due to high mechanical loss compared with SMES. A fusion power plant such as International Thermo-Nuclear Experimental Reactor (ITER) requires a large and long pulsed load which causes a frequency deviation in a utility power system. In order to keep the frequency within an allowable deviation, we propose a hybrid power system for the pulsed load, which equips the SMES and the FWMG with the utility power system. We evaluate installation cost and frequency control performance of three power systems combined with energy storage devices; (i) SMES with the utility power, (ii) FWMG with the utility power, (iii) both SMES and FWMG with the utility power. The first power system has excellent frequency power control performance but its installation cost is high. The second system has inferior frequency control performance but its installation cost is the lowest. The third system has good frequency control performance and its installation cost is attained lower than the first power system by adjusting the ratio between SMES and FWMG.

  17. An automated dynamic load for power system development

    NASA Technical Reports Server (NTRS)

    Whitehead, Norma Dugal; Kapustka, Robert E.

    1988-01-01

    This paper describes a dynamic load which is computer-controlled and has an increased bandwidth of more than 10 times that commercially available at the time the development of the project began. The load is 3 kW with a bandwidth of 35 kHz. The hardware and software are described, and the control circuitry is shown.

  18. An automated dynamic load for power system development

    NASA Technical Reports Server (NTRS)

    Whitehead, Norma Dugal; Kapustka, Robert E.

    1988-01-01

    This paper describes a dynamic load which is computer-controlled and has an increased bandwidth of more than 10 times that commercially available at the time the development of the project began. The load is 3 kW with a bandwidth of 35 kHz. The hardware and software are described, and the control circuitry is shown.

  19. Photovoltaic power converter system with a controller configured to actively compensate load harmonics

    DOEpatents

    de Rooij, Michael Andrew; Steigerwald, Robert Louis; Delgado, Eladio Clemente

    2008-12-16

    Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

  20. Real-Time Load-Side Control of Electric Power Systems

    NASA Astrophysics Data System (ADS)

    Zhao, Changhong

    Two trends are emerging from modern electric power systems: the growth of renewable (e.g., solar and wind) generation, and the integration of information technologies and advanced power electronics. The former introduces large, rapid, and random fluctuations in power supply, demand, frequency, and voltage, which become a major challenge for real-time operation of power systems. The latter creates a tremendous number of controllable intelligent endpoints such as smart buildings and appliances, electric vehicles, energy storage devices, and power electronic devices that can sense, compute, communicate, and actuate. Most of these endpoints are distributed on the load side of power systems, in contrast to traditional control resources such as centralized bulk generators. This thesis focuses on controlling power systems in real time, using these load side resources. Specifically, it studies two problems. (1) Distributed load-side frequency control: We establish a mathematical framework to design distributed frequency control algorithms for flexible electric loads. In this framework, we formulate a category of optimization problems, called optimal load control (OLC), to incorporate the goals of frequency control, such as balancing power supply and demand, restoring frequency to its nominal value, restoring inter-area power flows, etc., in a way that minimizes total disutility for the loads to participate in frequency control by deviating from their nominal power usage. By exploiting distributed algorithms to solve OLC and analyzing convergence of these algorithms, we design distributed load-side controllers and prove stability of closed-loop power systems governed by these controllers. This general framework is adapted and applied to different types of power systems described by different models, or to achieve different levels of control goals under different operation scenarios. We first consider a dynamically coherent power system which can be equivalently modeled with

  1. Load flow and state estimation algorithms for three-phase unbalanced power distribution systems

    NASA Astrophysics Data System (ADS)

    Madvesh, Chiranjeevi

    Distribution load flow and state estimation are two important functions in distribution energy management systems (DEMS) and advanced distribution automation (ADA) systems. Distribution load flow analysis is a tool which helps to analyze the status of a power distribution system under steady-state operating conditions. In this research, an effective and comprehensive load flow algorithm is developed to extensively incorporate the distribution system components. Distribution system state estimation is a mathematical procedure which aims to estimate the operating states of a power distribution system by utilizing the information collected from available measurement devices in real-time. An efficient and computationally effective state estimation algorithm adapting the weighted-least-squares (WLS) method has been developed in this research. Both the developed algorithms are tested on different IEEE test-feeders and the results obtained are justified.

  2. An Investigation to Resolve the Interaction Between Fuel Cell, Power Conditioning System and Application Loads

    SciTech Connect

    Sudip K. Mazumder

    2005-12-31

    Development of high-performance and durable solidoxide fuel cells (SOFCs) and a SOFC power-generating system requires knowledge of the feedback effects from the power-conditioning electronics and from application-electrical-power circuits that may pass through or excite the power-electronics subsystem (PES). Therefore, it is important to develop analytical models and methodologies, which can be used to investigate and mitigate the effects of the electrical feedbacks from the PES and the application loads (ALs) on the reliability and performance of SOFC systems for stationary and non-stationary applications. However, any such attempt to resolve the electrical impacts of the PES on the SOFC would be incomplete unless one utilizes a comprehensive analysis, which takes into account the interactions of SOFC, PES, balance-of-plant system (BOPS), and ALs as a whole. SOFCs respond quickly to changes in load and exhibit high part- and full-load efficiencies due to its rapid electrochemistry, which is not true for the thermal and mechanical time constants of the BOPS, where load-following time constants are, typically, several orders of magnitude higher. This dichotomy can affect the lifetime and durability of the SOFCSs and limit the applicability of SOFC systems for load-varying stationary and transportation applications. Furthermore, without validated analytical models and investigative design and optimization methodologies, realizations of cost-effective, reliable, and optimal PESs (and power-management controls), in particular, and SOFC systems, in general, are difficult. On the whole, the research effort can lead to (a) cost-constrained optimal PES design for high-performance SOFCS and high energy efficiency and power density, (b) effective SOFC power-system design, analyses, and optimization, and (c) controllers and modulation schemes for mitigation of electrical impacts and wider-stability margin and enhanced system efficiency.

  3. End-use load control for power system dynamic stability enhancement

    SciTech Connect

    Dagle, J.E.; Winiarski, D.W.; Donnelly, M.K.

    1997-02-01

    Faced with the prospect of increasing utilization of the transmission and distribution infrastructure without significant upgrade, the domestic electric power utility industry is investing heavily in technologies to improve network dynamic performance through a program loosely referred to as Flexible AC Transmission System (FACTS). Devices exploiting recent advances in power electronics are being installed in the power system to offset the need to construct new transmission lines. These devices collectively represent investment potential of several billion dollars over the next decade. A similar development, designed to curtail the peak loads and thus defer new transmission, distribution, and generation investment, falls under a category of technologies referred to as demand side management (DSM). A subset of broader conservation measures, DSM acts directly on the load to reduce peak consumption. DSM techniques include direct load control, in which a utility has the ability to curtail specific loads as conditions warrant. A novel approach has been conceived by Pacific Northwest National Laboratory (PNNL) to combine the objectives of FACTS and the technologies inherent in DSM to provide a distributed power system dynamic controller. This technology has the potential to dramatically offset major investments in FACTS devices by using direct load control to achieve dynamic stability objectives. The potential value of distributed versus centralized grid modulation has been examined by simulating the western power grid under extreme loading conditions. In these simulations, a scenario is analyzed in which active grid stabilization enables power imports into the southern California region to be increased several hundred megawatts beyond present limitations. Modeling results show distributed load control is up to 30 percent more effective than traditional centralized control schemes in achieving grid stability.

  4. Design, development and deployment of public service photovoltaic power/load systems for the Gabonese Republic

    NASA Astrophysics Data System (ADS)

    Kaszeta, William J.

    1987-04-01

    Five different types of public service photovoltaic power/load systems installed in the Gabonese Republic are discussed. The village settings, the systems, performance results and some problems encountered are described. Most of the systems performed well, but some of the systems had problems due to failure of components or installation errors. The project was reasonably successful in collecting and reporting data for system performance evaluation that will be useful for guiding officials and system designers involved in village power applications in developing countries.

  5. Design, development and deployment of public service photovoltaic power/load systems for the Gabonese Republic

    NASA Technical Reports Server (NTRS)

    Kaszeta, William J.

    1987-01-01

    Five different types of public service photovoltaic power/load systems installed in the Gabonese Republic are discussed. The village settings, the systems, performance results and some problems encountered are described. Most of the systems performed well, but some of the systems had problems due to failure of components or installation errors. The project was reasonably successful in collecting and reporting data for system performance evaluation that will be useful for guiding officials and system designers involved in village power applications in developing countries.

  6. Forecasting of hourly load by pattern recognition in a small area power system

    SciTech Connect

    Dehdashti-Shahrokh, A.

    1982-01-01

    An intuitive, logical, simple and efficient method of forecasting hourly load in a small area power system is presented. A pattern recognition approach is used in developing the forecasting model. Pattern recognition techniques are powerful tools in the field of artificial intelligence (cybernetics) and simulate the way the human brain operates to make decisions. Pattern recognition is generally used in analysis of processes where the total physical nature behind the process variation is unkown but specific kinds of measurements explain their behavior. In this research basic multivariate analyses, in conjunction with pattern recognition techniques, are used to develop a linear deterministic model to forecast hourly load. This method assumes that load patterns in the same geographical area are direct results of climatological changes (weather sensitive load), and have occurred in the past as a result of similar climatic conditions. The algorithm described in here searches for the best possible pattern from a seasonal library of load and weather data in forecasting hourly load. To accommodate the unpredictability of weather and the resulting load, the basic twenty-four load pattern was divided into eight three-hour intervals. This division was made to make the model adaptive to sudden climatic changes. The proposed method offers flexible lead times of one to twenty-four hours. The results of actual data testing had indicated that this proposed method is computationally efficient, highly adaptive, with acceptable data storage size and accuracy that is comparable to many other existing methods.

  7. An Estimation Method for Distribution System Load with Photovoltaic Power Generation based on ICA

    NASA Astrophysics Data System (ADS)

    Yamada, Takayoshi; Ishigame, Atsushi; Genji, Takamu

    A large number of Dispersed Generations (DGs) are expected to be installed in distribution systems. Therefore the state estimation is important problem for stable and reliable system operation. However, it is difficult to estimate the total power of DGs connected to a load-side system from a metering spot on the distribution line because at the metering spot only a sum of the active-power from various loads and DGs can be measured. In this paper, we propose an estimation method for unknown DG-outputs connected to a distribution system. This method enables to estimate DG-outputs by analyzing a power flow data measured at one spot using independent component analysis (ICA). The estimation by ICA needs the same number of observations as estimations. However the observation spot is extremely limited in existing distribution system. So we propose an estimation method which enables to estimate DG-outputs and load-changes from only an observation by using known information of load power and a priori knowledge of insolation.

  8. A fast, multi-period economic load dispatch for large-scale power systems

    SciTech Connect

    Ahmed, M.M.; Ghani, M.R.

    1999-11-01

    This paper presents optimized multi-period economic load dispatch solution for large-scale power system operations. The purpose is to achieve the required minimization of the operation cost of power generating units. Linear Programming, LaGrange Relaxation and Branch and Bound Methods were used. The combined algorithms used appear to be fast enough to meet the computation resource requirement of the system and to minimize the operating cost of generation units. An economic load dispatch with six period intervals has been formulated and successfully completed. The results found from the algorithm appears to be modest in both optimizing the operation cost and achieving fast computation time of dynamic economic load dispatch system.

  9. Model Predictive Load Frequency Control of two-area Interconnected Time Delay Power System with TCSC

    NASA Astrophysics Data System (ADS)

    Deng, Yan; Liu, Wenze

    2017-05-01

    In order to reduce the influence of non-linear constraint and time delay on load frequency control of interconnected power system, this paper, based on Model Predictive Control (MPC), designed a load frequency control scheme for two-area interconnected power system with TCSC device. First, considering the Generation Rate Constraint (GRC) and time delay, this paper builds the dynamics model of two-area interconnected power system with Thyristor Controlled Series Compensation device (TCSC). Then the whole system is decomposed into two subsystems. And each subsystem has its own local area MPC controller. Second, collaborative control is implemented by integrating the control information (measurement value, predictive value, etc.) of subsystems’ MPC controllers into the local control goal. In the end, under consideration of physical constraints, the Matlab simulation is conducted. The calculation results showed that the MPC strategy has better dynamic performance and robustness compared to the traditional PI control.

  10. Neuro-Fuzzy Computational Technique to Control Load Frequency in Hydro-Thermal Interconnected Power System

    NASA Astrophysics Data System (ADS)

    Prakash, S.; Sinha, S. K.

    2015-09-01

    In this research work, two areas hydro-thermal power system connected through tie-lines is considered. The perturbation of frequencies at the areas and resulting tie line power flows arise due to unpredictable load variations that cause mismatch between the generated and demanded powers. Due to rising and falling power demand, the real and reactive power balance is harmed; hence frequency and voltage get deviated from nominal value. This necessitates designing of an accurate and fast controller to maintain the system parameters at nominal value. The main purpose of system generation control is to balance the system generation against the load and losses so that the desired frequency and power interchange between neighboring systems are maintained. The intelligent controllers like fuzzy logic, artificial neural network (ANN) and hybrid fuzzy neural network approaches are used for automatic generation control for the two area interconnected power systems. Area 1 consists of thermal reheat power plant whereas area 2 consists of hydro power plant with electric governor. Performance evaluation is carried out by using intelligent (ANFIS, ANN and fuzzy) control and conventional PI and PID control approaches. To enhance the performance of controller sliding surface i.e. variable structure control is included. The model of interconnected power system has been developed with all five types of said controllers and simulated using MATLAB/SIMULINK package. The performance of the intelligent controllers has been compared with the conventional PI and PID controllers for the interconnected power system. A comparison of ANFIS, ANN, Fuzzy and PI, PID based approaches shows the superiority of proposed ANFIS over ANN, fuzzy and PI, PID. Thus the hybrid fuzzy neural network controller has better dynamic response i.e., quick in operation, reduced error magnitude and minimized frequency transients.

  11. A more efficient formulation for computation of the maximum loading points in electric power systems

    SciTech Connect

    Chiang, H.D.; Jean-Jumeau, R.

    1995-05-01

    This paper presents a more efficient formulation for computation of the maximum loading points. A distinguishing feature of the new formulation is that it is of dimension (n + 1), instead of the existing formulation of dimension (2n + 1), for n-dimensional load flow equations. This feature makes computation of the maximum loading points very inexpensive in comparison with those required in the existing formulation. A theoretical basis for the new formulation is provided. The new problem formulation is derived by using a simple reparameterization scheme and exploiting the special properties of the power flow model. Moreover, the proposed test function is shown to be monotonic in the vicinity of a maximum loading point. Therefore, it allows one to monitor the approach to maximum loading points during the solution search process. Simulation results on a 234-bus system are presented.

  12. An operational power management method for the grid containing renewable power systems utilizing short-term weather and load forecasting data

    NASA Astrophysics Data System (ADS)

    Aula, Fadhil T.; Lee, Samuel C.

    2013-04-01

    This paper addresses the problems associated with power management of the grid containing renewable power systems and proposes a method for enhancing its operational power management. Since renewable energy provides uncertain and uncontrollable energy resources, the renewable power systems can only generate irregular power. This power irregularity creates problems affecting the grid power management process and influencing the parallel operations of conventional power plants on the grid. To demonstrate this power management method for this type of grid, weatherdependent wind and photovoltaic power systems are chosen an example. This study also deals with other uncertain quantities which are system loads. In this example, the management method is based on adapting short-term weather and load forecasting data. The new load demand curve (NLDC) can be produced by merging the loads with the power generated from the renewable power systems. The NLDC is used for setting the loads for the baseload power plants and knowing when other plants are needed to increase or decrease their supplies to the grid. This will decrease the irregularity behavior effects of the renewable power system and at the same time will enhance the smoothing of the power management for the grid. The aim of this paper is to show the use of the weather and load forecasting data to achieve the optimum operational power management of the grid contains renewable power systems. An illustrative example of such a power system is presented and verified by simulation.

  13. The fuzzy regression approach to peak load estimation in power distribution systems

    SciTech Connect

    Nazarko, J.; Zalewski, W.

    1999-08-01

    This paper presents a new scheme based on the fuzzy regression analysis for the estimation of peak load in distribution systems. In distribution system, bus load estimation is complicated because system load is usually monitored at only a few points. As a rule receiving nodes are not equipped with stationary measuring instruments so measurements of loads are performed sporadically. In general, the only information commonly available regarding loads, other than major distribution substations and equipment installations, is billing cycle customer kWh consumption. In order to model system uncertainty, inexactness, and random nature of customers` demand, a fuzzy system approach is proposed. This paper presents possibilities of application of the fuzzy set theory to power distribution system calculations. Unreliable and inaccurate input data have been modeled by means of fuzzy numbers. Trapezoidal and triangular forms of fuzzy numbers were used for description of input data. A regression model, expressing the correlation between a substation peak load and a set of customer features (explanatory variables), existing in the substation population, is determined. Simulation studies have been performed to demonstrate the efficiency of the proposed scheme on the basis of actual data obtained at two distribution system substations. The same data have been used for building standard linear regression models. Comparison of the performance of both methods has been done.

  14. Load-Following Voltage Controller Design for a Static Space Nuclear Power System

    SciTech Connect

    Parlos, Alexander G.; Onbasioglou, Fetiye O.; Metzger, John D.

    2000-10-15

    The reliability of static space nuclear power systems (SNPSs) could be improved through the use of backup devices in addition to shunt regulators, as currently proposed for load following. Shunt regulator failure leading to reactor shutdown is possible, as is the possible need to deliver somewhat higher power level to the load than originally expected. A backup system is proposed in SNPSs to eliminate the possibility of a single-point failure in the shunt regulators and to increase the overall system power delivery capability despite changing mission needs and component characteristics. The objective of this paper is to demonstrate the feasibility of such a backup device for voltage regulation in static SNPSs that is capable of overcoming system variations resulting from operation at different power levels. A dynamic compensator is designed using the Linear Quadratic Gaussian with Loop Transfer Recovery method. The resulting compensators are gain scheduled using the SNPS electric power as the scheduling variable, resulting in a nonlinear compensator. The performance of the gain-scheduled compensator is investigated extensively using an SNPS simulator. The simulations demonstrate the effects of the fuel temperature reactivity coefficient variations on the load-following capabilities of the SNPS. Robustness analysis results demonstrate that the proposed controller exhibits significant operational flexibility, and it can be considered for long-term space mission requiring significant levels of autonomy.

  15. Power system security enhancement through direct non-disruptive load control

    NASA Astrophysics Data System (ADS)

    Ramanathan, Badri Narayanan

    The transition to a competitive market structure raises significant concerns regarding reliability of the power grid. A need to build tools for security assessment that produce operating limit boundaries for both static and dynamic contingencies is recognized. Besides, an increase in overall uncertainty in operating conditions makes corrective actions at times ineffective leaving the system vulnerable to instability. The tools that are in place for stability enhancement are mostly corrective and suffer from lack of robustness to operating condition changes. They often pose serious coordination challenges. With deregulation, there have also been ownership and responsibility issues associated with stability controls. However, the changing utility business model and the developments in enabling technologies such as two-way communication, metering, and control open up several new possibilities for power system security enhancement. This research proposes preventive modulation of selected loads through direct control for power system security enhancement. Two main contributions of this research are the following: development of an analysis framework and two conceptually different analysis approaches for load modulation to enhance oscillatory stability, and the development and study of algorithms for real-time modulation of thermostatic loads. The underlying analysis framework is based on the Structured Singular Value (SSV or mu) theory. Based on the above framework, two fundamentally different approaches towards analysis of the amount of load modulation for desired stability performance have been developed. Both the approaches have been tested on two different test systems: CIGRE Nordic test system and an equivalent of the Western Electric Coordinating Council test system. This research also develops algorithms for real-time modulation of thermostatic loads that use the results of the analysis. In line with some recent load management programs executed by utilities, two

  16. Hybrid power system intelligent operation and protection involving distributed architectures and pulsed loads

    NASA Astrophysics Data System (ADS)

    Mohamed, Ahmed

    Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available

  17. High-Power Rf Load

    DOEpatents

    Tantawi, Sami G.; Vlieks, Arnold E.

    1998-09-01

    A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

  18. New approaches to provide ride-through for critical loads in electric power distribution systems

    NASA Astrophysics Data System (ADS)

    Montero-Hernandez, Oscar C.

    2001-07-01

    The extensive use of electronic circuits has enabled modernization, automation, miniaturization, high quality, low cost, and other achievements regarding electric loads in the last decades. However, modern electronic circuits and systems are extremely sensitive to disturbances from the electric power supply. In fact, the rate at which these disturbances happen is considerable as has been documented in recent years. In response to the power quality concerns presented previously, this dissertation is proposing new approaches to provide ride-through for critical loads during voltage disturbances with emphasis on voltage sags. In this dissertation, a new approach based on an AC-DC-AC system is proposed to provide ride-through for critical loads connected in buildings and/or an industrial system. In this approach, a three-phase IGBT inverter with a built in Dc-link voltage regulator is suitably controlled along with static by-pass switches to provide continuous power to critical loads. During a disturbance, the input utility source is disconnected and the power from the inverter is connected to the load. The remaining voltage in the AC supply is converted to DC and compensated before being applied to the inverter and the load. After detecting normal utility conditions, power from the utility is restored to the critical load. In order to achieve an extended ride-through capability a second approach is introduced. In this case, the Dc-link voltage regulator is performed by a DC-DC Buck-Boost converter. This new approach has the capability to mitigate voltage variations below and above the nominal value. In the third approach presented in this dissertation, a three-phase AC to AC boost converter is investigated. This converter provides a boosting action for the utility input voltages, right before they are applied to the load. The proposed Pulse Width Modulation (PWM) control strategy ensures independent control of each phase and compensates for both single-phase or poly

  19. Large Hybrid Energy Systems for Making Low CO2 Load-Following Power and Synthetic Fuel

    SciTech Connect

    Robert S. Cherry; Richard D. Boardman; Steven Aumeier

    2012-02-01

    Hybrid energy systems using nuclear heat sources can economically produce load-following electrical power by exploiting the surplus generation capacity available at night or seasonally to make synthetic fuel. Vehicle fuel is the only current energy use large enough to absorb all the energy capacity that might be diverted from the power industry, and its ease of storage obviates problems with discontinuous synfuel production. The potential benefits and challenges of synfuels integration are illustrated by the production of methanol from natural gas (as a source of carbon) using steam from a light water nuclear power reactor which is assumed to be available in accord with a year's worth of power demand data. Methanol's synthesis process is easily adapted to using 300 C heat from a light water reactor and this simple compound can be further processed into gasoline, biodiesel, or dimethyl ether, fuels which can be used with the current vehicle fleet. A supplemental feed to the methanol process of natural gas (for energy) allows operation at constant full rate when the nuclear heat is being used to produce electrical power. The higher capital costs of such a system are offset by a lower cost of heat and power production from a large base load type of plant and by reduced costs associated with much lower CO2 emissions. Other less tangible economic benefits of this and similar hybrid systems include better use of natural resource for fuels and greater energy services security from the domestic production of vehicle fuel.

  20. AN INVESTIGATION TO RESOLVE THE INTERACTION BETWEEN FUEL CELL, POWER CONDITIONING SYSTEM AND APPLICATION LOADS

    SciTech Connect

    Sudip K. Mazumder; Chuck McKintyre; Dan Herbison; Doug Nelson; Comas Haynes; Michael von Spakovsky; Joseph Hartvigsen; S. Elangovan

    2003-11-03

    Solid-Oxide Fuel Cell (SOFC) stacks respond quickly to changes in load and exhibit high part- and full-load efficiencies due to its rapid electrochemistry. However, this is not true for the thermal, mechanical, and chemical balance-of-plant subsystem (BOPS), where load-following time constants are, typically, several orders of magnitude higher. This dichotomy diminishes the reliability and performance of the electrode with increasing demand of load. Because these unwanted phenomena are not well understood, the manufacturers of SOFC use conservative schemes (such as, delayed load-following to compensate for slow BOPS response or expensive inductor filtering) to control stack responses to load variations. This limits the applicability of SOFC systems for load-varying stationary and transportation applications from a cost standpoint. Thus, a need exists for the synthesis of component- and system-level models of SOFC power-conditioning systems and the development of methodologies for investigating the system-interaction issues (which reduce the lifetime and efficiency of a SOFC) and optimizing the responses of each subsystem, leading to optimal designs of power-conditioning electronics and optimal control strategies, which mitigate the electrical-feedback effects. Equally important are ''multiresolution'' finite-element modeling and simulation studies, which can predict the impact of changes in system-level variables (e.g., current ripple and load-transients) on the local current densities, voltages, and temperature (these parameters are very difficult or cumbersome, if not impossible to obtain) within a SOFC cell. Towards that end, for phase I of this project, sponsored by the U.S. DOE (NETL), we investigate the interactions among fuel cell, power-conditioning system, and application loads and their effects on SOFC reliability (durability) and performance. A number of methodologies have been used in Phase I to develop the steady-state and transient nonlinear models of

  1. Effect of Load on Peak Power of the Bar, Body and System during the Deadlift.

    PubMed

    Blatnik, Justin A; Goodman, Courtney L; Capps, Christopher R; Awelewa, Olumide O; Triplett, Travis N; Erickson, Travis M; McBride, Jeffery M

    2014-09-01

    The purpose of this investigation was to examine how load would affect peak power (PP) of the bar, body and system (bar + body) during the deadlift. Eight healthy males (age = 22.00 ± 2.38 years; height = 1.80 ± 0.05 m; body mass = 88.97 ± 14.88 kg; deadlift one repetition maximum [1RM] = 203.44 ± 21.59 kg, 1RM/BM = 2.32 ± 0.31) with a minimum of 2 years' resistance training experience and a deadlift 1RM over 1.5 times their bodyweight participated in the investigation. During the first session, anthropometric data were recorded and a 1RM deadlift was obtained from the participants. During the second session, participants performed two repetitions at intensities of 30, 40, 50, 60, 70, 80 and 90% of their 1RM in a randomized order. Three-dimensional videography with a force plate was used for data collection and analysis. Peak force (PF), peak velocity (PV), an d PP were calculated for the bar, body, and system (bar + body) during the deadlift. PP occurred at 50%, 30%, and 70% of 1RM for the bar, body, and system, respectively. The optimal loading for the deadlift exercise may vary depending on the desired stimulus and whether the bar, body, or system variables are of most interest. Key pointsPeak power of the bar, body and system vary depending upon load.Loading should be chosen according to desired training effect, with considerations for sport specificity.Additional exercises should be investigated concerning the effect of various loads on power.

  2. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution DC test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF Program design and development phases, a system Power Management and Distribution (PMAD) DC test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  3. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  4. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  5. Efficient ways for setting up the operation of nuclear power stations in power systems in the base load mode

    NASA Astrophysics Data System (ADS)

    Aminov, R. Z.; Shkret, A. F.; Burdenkova, E. Yu.; Garievskii, M. V.

    2011-05-01

    The results obtained from studies of efficient ways and methods for organizing the operation of developing nuclear power stations in the base load mode are presented. We also show comparative efficiency of different scenarios for unloading condensing thermal power stations, cogeneration stations, combined-cycle power plants, nuclear power stations, and using off-peak electric energy for electricity-intensive loads: pumped-hydroelectric storage, electric-powered heat supply, and electrolysis of water for producing hydrogen and oxygen.

  6. Optimization of disk generator performance for base-load power plant systems applications

    SciTech Connect

    Teare, J D; Loubsky, W J; Lytle, J K; Louis, J F

    1980-01-01

    Disk generators for use in base-load MHD power plants are examined for both open-cycle and closed-cycle operating modes. The OCD cases are compared with PSPEC results for a linear channel; enthalpy extractions up to 23% with 71% isentropic efficiency are achievable with generator inlet conditions similar to those used in PSPEC, thus confirming that the disk configuration is a viable alternative for base-load power generation. The evaluation of closed-cycle disks includes use of a simplified cycle model. High system efficiencies over a wide range of power levels are obtained for effective Hall coefficients in the range 2.3 to 4.9. Cases with higher turbulence (implying ..beta../sub eff/ less than or equal to 2.4) yield high system efficiencies at power levels of 100 to 500 MW/sub e/. All these CCD cases compare favorably with linear channels reported in the GE ECAS study, yielding higher isentropic efficiences for a given enthalpy extraction. Power densities in the range 70 to 170 MW/m/sup 3/ appear feasible, leading to very compact generator configurations.

  7. Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System

    DTIC Science & Technology

    2009-07-30

    Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System Jarrett Goodell and...TITLE AND SUBTITLE Investigation of Control Algorithms for Tracked Vehicle Mobility Load Emulation for a Combat Hybrid Electric Power System 5a...for ~ 22 ton tracked vehicle • Tested and Developed: – Motors, Generators, Batteries, Inverters, DC-DC Converters , Thermal Management, Pulse Power

  8. Load sensing system

    DOEpatents

    Sohns, Carl W.; Nodine, Robert N.; Wallace, Steven Allen

    1999-01-01

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

  9. Design and Stability of Load-Side Primary Frequency Control in Power Systems

    SciTech Connect

    Zhao, CH; Topcu, U; Li, N; Low, S

    2014-05-01

    We present a systematic method to design ubiquitous continuous fast-acting distributed load control for primary frequency regulation in power networks, by formulating an optimal load control (OLC) problem where the objective is to minimize the aggregate cost of tracking an operating point subject to power balance over the network. We prove that the swing dynamics and the branch power flows, coupled with frequency-based load control, serve as a distributed primal-dual algorithm to solve OLC. We establish the global asymptotic stability of a multimachine network under such type of load-side primary frequency control. These results imply that the local frequency deviations on each bus convey exactly the right information about the global power imbalance for the loads to make individual decisions that turn out to be globally optimal. Simulations confirm that the proposed algorithm can rebalance power and resynchronize bus frequencies after a disturbance with significantly improved transient performance.

  10. Study of regeneration system of 300 MW power unit based on nondeaerating heat balance diagram at reduced load

    NASA Astrophysics Data System (ADS)

    Esin, S. B.; Trifonov, N. N.; Sukhorukov, Yu. G.; Yurchenko, A. Yu.; Grigor'eva, E. B.; Snegin, I. P.; Zhivykh, D. A.; Medvedkin, A. V.; Ryabich, V. A.

    2015-09-01

    More than 30 power units of thermal power stations, based on the nondeaerating heat balance diagram, successfully operate in the former Soviet Union. Most of them are power units with a power of 300 MW, equipped with HTGZ and LMZ turbines. They operate according to a variable electric load curve characterized by deep reductions when undergoing night minimums. Additional extension of the range of power unit adjustment makes it possible to maintain the dispatch load curve and obtain profit for the electric power plant. The objective of this research is to carry out estimated and experimental processing of the operating regimes of the regeneration system of steam-turbine plants within the extended adjustment range and under the conditions when the constraints on the regeneration system and its equipment are removed. Constraints concerning the heat balance diagram that reduce the power unit efficiency when extending the adjustment range have been considered. Test results are presented for the nondeaerating heat balance diagram with the HTGZ turbine. Turbine pump and feed electric pump operation was studied at a power unit load of 120-300 MW. The reliability of feed pump operation is confirmed by a stable vibratory condition and the absence of cavitation noise and vibration at a frequency that characterizes the cavitation condition, as well as by oil temperature maintenance after bearings within normal limits. Cavitation performance of pumps in the studied range of their operation has been determined. Technical solutions are proposed on providing a profitable and stable operation of regeneration systems when extending the range of adjustment of power unit load. A nondeaerating diagram of high-pressure preheater (HPP) condensate discharge to the mixer. A regeneration system has been developed and studied on the operating power unit fitted with a deaeratorless thermal circuit of the system for removing the high-pressure preheater heating steam condensate to the mixer

  11. Systems and methods for providing power to a load based upon a control strategy

    DOEpatents

    Perisic, Milun; Lawrence, Christopher P; Ransom, Ray M; Kajouke, Lateef A

    2014-11-04

    Systems and methods are provided for an electrical system. The electrical system, for example, includes a first load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage through the interface and to provide a voltage and current to the first load. The controller may be further configured to, receive information on a second load electrically connected to the voltage source, determine an amount of reactive current to return to the voltage source such that a current drawn by the electrical system and the second load from the voltage source is substantially real, and provide the determined reactive current to the voltage source.

  12. Multi-Temporal Decomposed Wind and Load Power Models for Electric Energy Systems

    NASA Astrophysics Data System (ADS)

    Abdel-Karim, Noha

    This thesis is motivated by the recognition that sources of uncertainties in electric power systems are multifold and may have potentially far-reaching effects. In the past, only system load forecast was considered to be the main challenge. More recently, however, the uncertain price of electricity and hard-to-predict power produced by renewable resources, such as wind and solar, are making the operating and planning environment much more challenging. The near-real-time power imbalances are compensated by means of frequency regulation and generally require fast-responding costly resources. Because of this, a more accurate forecast and look-ahead scheduling would result in a reduced need for expensive power balancing. Similarly, long-term planning and seasonal maintenance need to take into account long-term demand forecast as well as how the short-term generation scheduling is done. The better the demand forecast, the more efficient planning will be as well. Moreover, computer algorithms for scheduling and planning are essential in helping the system operators decide what to schedule and planners what to build. This is needed given the overall complexity created by different abilities to adjust the power output of generation technologies, demand uncertainties and by the network delivery constraints. Given the growing presence of major uncertainties, it is likely that the main control applications will use more probabilistic approaches. Today's predominantly deterministic methods will be replaced by methods which account for key uncertainties as decisions are made. It is well-understood that although demand and wind power cannot be predicted at very high accuracy, taking into consideration predictions and scheduling in a look-ahead way over several time horizons generally results in more efficient and reliable utilization, than when decisions are made assuming deterministic, often worst-case scenarios. This change is in approach is going to ultimately require new

  13. Load sensing system

    DOEpatents

    Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

    1999-05-04

    A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

  14. A robust PID controller based on imperialist competitive algorithm for load-frequency control of power systems.

    PubMed

    Shabani, Hamed; Vahidi, Behrooz; Ebrahimpour, Majid

    2013-01-01

    A new PID controller for resistant differential control against load disturbance is introduced that can be used for load frequency control (LFC) application. Parameters of the controller have been specified by using imperialist competitive algorithm (ICA). Load disturbance, which is due to continuous and rapid changes of small loads, is always a problem for load frequency control of power systems. This paper introduces a new method to overcome this problem that is based on filtering technique which eliminates the effect of this kind of disturbance. The object is frequency regulation in each area of the power system and decreasing of power transfer between control areas, so the parameters of the proposed controller have been specified in a wide range of load changes by means of ICA to achieve the best dynamic response of frequency. To evaluate the effectiveness of the proposed controller, a three-area power system is simulated in MATLAB/SIMULINK. Each area has different generation units, so utilizes controllers with different parameters. Finally a comparison between the proposed controller and two other prevalent PI controllers, optimized by GA and Neural Networks, has been done which represents advantages of this controller over others. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Generation/transmission power system reliability evaluation by Monte-Carlo simulation assuming a fuzzy load description

    SciTech Connect

    Saraiva, J.T.; Miranda, V.; Pinto, L.M.V.G.

    1996-05-01

    This paper presents a Monte-Carlo algorithm considering loads defined by fuzzy numbers. In this methodology states are sampled according to the probabilistic models governing the life cycle of system components while fuzzy concepts are used to model uncertainty related to future load behavior. This model can be used to evaluate generation/transmission power system reliability for long term planning studies as one uses the more adequate uncertainty models for each type of data. For each sampled state a Fuzzy Optimal Power Flow is run so that one builds its power not supplied membership function. The paper proposes new indices reflecting the integration of probabilistic models and fuzzy concepts and discusses the application of variance reduction techniques if loads are defined by fuzzy numbers. A case-study based on the IEEE 30 bus system illustrates this methodology.

  16. Generation/transmission power system reliability evaluation by Monte-Carlo simulation assuming a fuzzy load description

    SciTech Connect

    Saraiva, J.T.; Miranda, V.; Pint, L.M.V.G.

    1995-12-31

    This paper presents a Monte-Carlo algorithm considering loads defined by fuzzy numbers. In this methodology states are sampled according to the probabilistic models governing the life cycle of system components while fuzzy concepts are used to model uncertainty related to future load behavior. This model can be used to evaluate generation/transmission power system reliability for long term planning studies as one uses the more adequate uncertainty models for each type of data. For each sampled state a Fuzzy Optimal Power Flow is run so that one builds its power not supplied membership function. The paper proposes new indices reflecting the integration of probabilistic models and fuzzy concepts and discusses the application of variance reduction techniques if loads are defined by fuzzy numbers. A case-study based on the IEEE 30 bus system illustrates this methodology.

  17. A new control scheme for PID load frequency controller of single-area and multi-area power systems.

    PubMed

    Padhan, Dola Gobinda; Majhi, Somanath

    2013-03-01

    A new control structure with a tuning method to design a PID load frequency controller for power systems is presented. Initially, the controller is designed for single area power system, then it is extended to multi-area case. The controller parameters are obtained by expanding controller transfer function using Laurent series. Relay based identification technique is adopted to estimate power system dynamics. Robustness studies on stability and performance are provided, with respect to uncertainties in the plant parameters. The proposed scheme ensures that overall system remains asymptotically stable for all bounded uncertainties and for system oscillations. Simulation results show the feasibility of the approach and the proposed method improves the load disturbance rejection performance significantly even in the presence of the uncertainties in plant parameters.

  18. Radio frequency power load and associated method

    NASA Technical Reports Server (NTRS)

    Sims, III, William Herbert (Inventor); Chavers, Donald Gregory (Inventor); Richeson, James J. (Inventor)

    2010-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus includes a container and a fluid having an ion source therein, the fluid being contained in the container. Two conductors are immersed in the fluid. A radio frequency transmission system includes a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus includes a fluid having an ion source therein, and two conductors immersed in the fluid. A method of dissipating power generated by a radio frequency transmission system includes the steps of: immersing two conductors of a radio frequency power load apparatus in a fluid having an ion source therein; and connecting the apparatus to an amplifier of the transmission system.

  19. Power management system

    DOEpatents

    Algrain, Marcelo C.; Johnson, Kris W.; Akasam, Sivaprasad; Hoff, Brian D.

    2007-10-02

    A method of managing power resources for an electrical system of a vehicle may include identifying enabled power sources from among a plurality of power sources in electrical communication with the electrical system and calculating a threshold power value for the enabled power sources. A total power load placed on the electrical system by one or more power consumers may be measured. If the total power load exceeds the threshold power value, then a determination may be made as to whether one or more additional power sources is available from among the plurality of power sources. At least one of the one or more additional power sources may be enabled, if available.

  20. An expansion plan for the 60 Hz power distribution system at KSC: LC-39 substations load allocation plan

    NASA Technical Reports Server (NTRS)

    Kalu, Alex

    1990-01-01

    The increasing load density in the LC-39 area of Kennedy Space Center (KSC) can be met by either modifying the existing substation and increasing its capacity or by planning an additional new substation. Evidence that the later approach is more economical, enhances the system reliability, and would produce more satisfactory performance indices is provided. Network theory is the basis for the optimal location determination of the proposed substation. A load reallocation plan which minimizes investment cost and power losses and meets other desirable system features is drafted. The report should be useful to the system designer and can be a useful guideline for future facility planners.

  1. Analysis of a dc bus system with a nonlinear constant power load and its delayed feedback control.

    PubMed

    Konishi, Keiji; Sugitani, Yoshiki; Hara, Naoyuki

    2014-02-01

    This paper tackles a destabilizing problem of a direct-current (dc) bus system with constant power loads, which can be considered a fundamental problem of dc power grid networks. The present paper clarifies scenarios of the destabilization and applies the well-known delayed-feedback control to the stabilization of the destabilized bus system on the basis of nonlinear science. Further, we propose a systematic procedure for designing the delayed feedback controller. This controller can converge the bus voltage exactly on an unstable operating point without accurate information and can track it using tiny control energy even when a system parameter, such as the power consumption of the load, is slowly varied. These features demonstrate that delayed feedback control can be considered a strong candidate for solving the destabilizing problem.

  2. Restrictive loads powered by separate or by common electrical sources

    NASA Technical Reports Server (NTRS)

    Appelbaum, J.

    1989-01-01

    In designing a multiple load electrical system, the designer may wish to compare the performance of two setups: a common electrical source powering all loads, or separate electrical sources powering individual loads. Three types of electrical sources: an ideal voltage source, an ideal current source, and solar cell source powering resistive loads were analyzed for their performances in separate and common source systems. A mathematical proof is given, for each case, indicating the merit of the separate or common source system. The main conclusions are: (1) identical resistive loads powered by ideal voltage sources perform the same in both system setups, (2) nonidentical resistive loads powered by ideal voltage sources perform the same in both system setups, (3) nonidentical resistive loads powered by ideal current sources have higher performance in separate source systems, and (4) nonidentical resistive loads powered by solar cells have higher performance in a common source system for a wide range of load resistances.

  3. Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    SciTech Connect

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-01-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter

  4. Load Control System Reliability

    SciTech Connect

    Trudnowski, Daniel

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  5. Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    SciTech Connect

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.; Ma, Jian; Guttromson, Ross T.; Subbarao, Krishnappa; Chakrabarti, Bhujanga B.

    2010-09-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique

  6. Radio Frequency Power Load and Associated Method

    NASA Technical Reports Server (NTRS)

    Srinivasan, V. Karthik (Inventor); Freestone, Todd M. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A radio frequency power load and associated method. A radio frequency power load apparatus may include a container with an ionized fluid therein. The apparatus may include one conductor immersed in a fluid and another conductor electrically connected to the container. A radio frequency transmission system may include a radio frequency transmitter, a radio frequency amplifier connected to the transmitter and a radio frequency power load apparatus connected to the amplifier. The apparatus may include a fluid having an ion source therein, one conductor immersed in a fluid, and another conductor electrically connected to the container. A method of dissipating power generated by a radio frequency transmission system may include constructing a waveguide with ionized fluid in a container and connecting the waveguide to an amplifier of the transmission system.

  7. A system-level mathematical model for evaluation of power train performance of load-leveled electric-vehicles

    NASA Technical Reports Server (NTRS)

    Purohit, G. P.; Leising, C. J.

    1984-01-01

    The power train performance of load leveled electric vehicles can be compared with that of nonload leveled systems by use of a simple mathematical model. This method of measurement involves a number of parameters including the degree of load leveling and regeneration, the flywheel mechanical to electrical energy fraction, and efficiencies of the motor, generator, flywheel, and transmission. Basic efficiency terms are defined and representative comparisons of a variety of systems are presented. Results of the study indicate that mechanical transfer of energy into and out of the flywheel is more advantageous than electrical transfer. An optimum degree of load leveling may be achieved in terms of the driving cycle, battery characteristics, mode of mechanization, and the efficiency of the components. For state of the art mechanically coupled flyheel systems, load leveling losses can be held to a reasonable 10%; electrically coupled systems can have losses that are up to six times larger. Propulsion system efficiencies for mechanically coupled flywheel systems are predicted to be approximately the 60% achieved on conventional nonload leveled systems.

  8. System for conveniently providing load testing termination of an AC power source having at least one battery

    NASA Astrophysics Data System (ADS)

    Morell, Wilbert J., III

    1995-05-01

    An AC uninterruptible power source is disclosed that provides multiphase power output signals for actual use and a selectable single phase power output signal for use in testing. The AC uninterruptible power source further comprises at least one battery. The single phase output signal is connected to a dummy load by means of a power switch of the break before make type. The invention further includes the dummy load as preferably having metering capabilities to measure the frequency, current, and voltage parameters of the single phase output signal. The arrangement of the present invention allows for the single phase output to be mated to the dummy load without the need of removing input power to the AC uninterruptible power source so as to reduce, or even eliminate, transient caused failures to the AC uninterruptible power source and to its sensitive load equipment which the power source services.

  9. Reactive power optimization using fuzzy load representation

    SciTech Connect

    Abdul-Rahman, K.H.; Shahidehpour, S.M. . Dept. of Electrical and Computer Engineering)

    1994-05-01

    This paper presents a mathematical formulation for the optimal voltage/reactive power control problem taking into account linguistic declaration of system load values. The fuzzy set theory which is based on the feasibility rather than the frequency of occurrence of an outcome is considered, and possibility distributions are assigned to load values and bus voltages. The objective is to minimize power losses considering various load conditions. The problem is decomposed into four subproblems via the Dantzig-Wolfe decomposition for reducing the dimensions of the problem. A second Dantzig-Wolfe decomposition divides each subproblem into several areas leading to a considerable reduction in the dimensions of subproblems. An illustrative example demonstrates the applicability of the approach. The fuzzy approach provides a global solution for the system behavior under various load conditions.

  10. Design of an all-fiber erbium-doped laser system for simulating power load in backbone networks

    NASA Astrophysics Data System (ADS)

    Pobořil, Radek; Bednárek, Lukáš; Vanderka, Aleš; Hájek, Lukáš; Zbořil, Ondřej; Vašinek, Vladimír

    2016-12-01

    This article is focused on the design of an all-fiber laser that was supposed to be used for simulating power load similar to the power load in backbone networks. The first part of the article is a brief introduction to the topic of lasers and erbium doped fiber amplifiers. The following parts present design of a fiber laser with ring cavity, and measuring the ideal length of a doped fiber and the split ratio of the output coupler. After proposing the first stage -a laser- we focused on the construction of the two following stages -EDFA preamplifier and EDFA amplifier. There were used fibers with various levels of erbium ion density, namely ISO-GAIN I6, and Liekki ER110-4/125. The resulting output power of the whole system was 320 mW. This value is sufficient when we take into account that we used only single-mode fibers with energy pumped directly to the fiber core. The output wavelength of the whole laser system was 1559 nm.

  11. An Set-Free, All Digital Controlled Point-of-Load Regulator for Next Generation Power Systems: ADC-POL

    NASA Technical Reports Server (NTRS)

    Adell, Philippe C.; Liu, Tao; Vermeire, Bert; Bakkaloglu, Bertan; Aveline, David

    2011-01-01

    This paper presents a digitally controlled programmable point-of-load regulator for next-generation power systems. A novel digital control scheme was designed to minimize single-event effect (SEE)-induced transient effects. By effectively programming the loop transmission, the POL can trade off transient response time with SET robustness. The IC works with 1 to 5.5 V input voltage, 1-4.5V regulated output voltage, high efficiency (peak efficiency at 94%) and power of up to 5 W. The design was fabricated in the AMI i2t100 0.7 mu m complimentary, metal-oxide semiconductor (CMOS) process and characterized with the Jet Propulsion Laboratory (JPL) pulsed laser system.

  12. Multi-load Groups Coordinated Load Control Strategy Considering Power Network Constraints

    NASA Astrophysics Data System (ADS)

    Liu, Meng; Zhao, Binchao; Wang, Jun; Zhang, Guohui; Wang, Xin

    2017-05-01

    Loads with energy storage property can actively participate in power balance for power systems, this paper takes air conditioner as a controllable load example, proposing a multi-load groups coordinated load control strategy considering power network constraints. Firstly, two load control modes considering recovery of load diversity are designed, blocking power oscillation of aggregated air conditioners. As the same time, air conditioner temperature setpoint recovery control strategy is presented to avoid power recovery peak. Considering inherent characteristics of two load control modes, an coordinated load control mode is designed by combining the both. Basing on this, a multi-load groups coordinated load control strategy is proposed. During the implementing of load control, power network constraints should be satisfied. An indice which can reflect the security of power system operating is defined. By minimizing its value through optimization, the change of air conditioning loads’ aggregated power on each load bus can be calculated. Simulations are conducted on an air conditioners group and New England 10-generator 39-bus system, verifying the effectiveness of the proposed multi-load groups coordinated load control strategy considering power network constraints.

  13. Electronic load for testing power generating devices

    NASA Technical Reports Server (NTRS)

    Friedman, E. B.; Stepfer, G.

    1968-01-01

    Instrument tests various electric power generating devices by connecting the devices to the input of the load and comparing their outputs with a reference voltage. The load automatically adjusts until voltage output of the power generating device matches the reference.

  14. Optimizing the Operation of Windfarms, Energy Storage and Flexible Loads in Modern Power Systems and Deregulated Electricity Markets

    NASA Astrophysics Data System (ADS)

    Dar, Zamiyad

    most turbines is quite close to 1/3 and yaw angle acts as the dominant optimization variable. In the next part of this dissertation, a system comprising of a windfarm and energy storage operating in real-time electricity markets is studied. An Energy-balancing Threshold Price (ETP) policy is proposed to maximize the revenue of a windfarm with on-site storage. We propose and analyze a scheme for a windfarm to store or sell energy based on a threshold price. The threshold price is calculated based on long-term distributions of the electricity price and wind power generation processes, and is chosen so as to balance the energy flows in and out of the storage-equipped windfarm. It is also shown mathematically that the proposed policy is optimal in terms of the long-term revenue generated. Comparing it with the optimal policy that has knowledge of the future, we observe that the revenue obtained by the proposed ETP policy is approximately 90% of the maximum attainable revenue at a storage capacity of 10-15 times the power rating of the windfarm. The intermittent nature of wind power is a hindrance to the efficient participation of windfarms in the day-ahead and forward electricity markets. In this regard, a flexible forward contract is proposed in this dissertation which allows the windfarms to enter into a forward contract with flexible load with an option to deviate from the contracted amount of power. Using such a flexible contract would allow the windfarms to supply more or less than the contracted amount of power in case of unexpected wind conditions or real-time prices. We also propose models for forecasting wind power and real-time electricity prices. The comparison between the proposed contracting framework and a simple fixed contract (currently existing in the market) for different levels of flexibility and load shows that there is a net gain in windfarm revenues, if the transaction price of the two contracts are set equal. Lastly, we present and analyze

  15. Load Modeling and State Estimation Methods for Power Distribution Systems: Final Report

    SciTech Connect

    Tom McDermott

    2010-05-07

    The project objective was to provide robust state estimation for distribution systems, comparable to what has been available on transmission systems for decades. This project used an algorithm called Branch Current State Estimation (BCSE), which is more effective than classical methods because it decouples the three phases of a distribution system, and uses branch current instead of node voltage as a state variable, which is a better match to current measurement.

  16. Power control system and method

    DOEpatents

    Steigerwald, Robert Louis; Anderson, Todd Alan

    2006-11-07

    A power system includes an energy harvesting device, a battery coupled to the energy harvesting device, and a circuit coupled to the energy harvesting device and the battery. The circuit is adapted to deliver power to a load by providing power generated by the energy harvesting device to the load without delivering excess power to the battery and to supplement the power generated by the energy harvesting device with power from the battery if the power generated by the energy harvesting device is insufficient to fully power the load. A method of operating the power system is also provided.

  17. Power control system and method

    DOEpatents

    Steigerwald, Robert Louis [Burnt Hills, NY; Anderson, Todd Alan [Niskayuna, NY

    2008-02-19

    A power system includes an energy harvesting device, a battery coupled to the energy harvesting device, and a circuit coupled to the energy harvesting device and the battery. The circuit is adapted to deliver power to a load by providing power generated by the energy harvesting device to the load without delivering excess power to the battery and to supplement the power generated by the energy harvesting device with power from the battery if the power generated by the energy harvesting device is insufficient to fully power the load. A method of operating the power system is also provided.

  18. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Ashworth, Barry; Riedesel, Joel; Myers, Chris; Miller, William; Jones, Ellen F.; Freeman, Kenneth; Walsh, Richard; Walls, Bryan K.; Weeks, David J.; Bechtel, Robert T.

    1992-01-01

    Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.

  19. Power system

    DOEpatents

    Hickam, Christopher Dale

    2008-03-18

    A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

  20. The effect of real-time pricing on load shifting in a highly renewable power system dominated by generation from the renewable sources of wind and photovoltaics

    NASA Astrophysics Data System (ADS)

    Kies, Alexander; Brown, Tom; Schlachtberger, David; Schramm, Stefan

    2017-04-01

    The supply-demand imbalance is a major concern in the presence of large shares of highly variable renewable generation from sources like wind and photovoltaics (PV) in power systems. Other than the measures on the generation side, such as flexible backup generation or energy storage, sector coupling or demand side management are the most likely option to counter imbalances, therefore to ease the integration of renewable generation. Demand side management usually refers to load shifting, which comprises the reaction of electricity consumers to price fluctuations. In this work, we derive a novel methodology to model the interplay of load shifting and provided incentives via real-time pricing in highly renewable power systems. We use weather data to simulate generation from the renewable sources of wind and photovoltaics, as well as historical load data, split into different consumption categories, such as, heating, cooling, domestic, etc., to model a simplified power system. Together with renewable power forecast data, a simple market model and approaches to incorporate sector coupling [1] and load shifting [2,3], we model the interplay of incentives and load shifting for different scenarios (e.g., in dependency of the risk-aversion of consumers or the forecast horizon) and demonstrate the practical benefits of load shifting. First, we introduce the novel methodology and compare it with existing approaches. Secondly, we show results of numerical simulations on the effects of load shifting: It supports the integration of PV power by providing a storage, which characteristics can be described as "daily" and provides a significant amount of balancing potential. Lastly, we propose an experimental setup to obtain empirical data on end-consumer load-shifting behaviour in response to price incentives. References [1] Brown, T., Schlachtberger, D., Kies. A., Greiner, M., Sector coupling in a highly renewable European energy system, Proc. of the 15th International Workshop on

  1. Testing of Uninterruptible Power Supplies with nonlinear loads

    NASA Astrophysics Data System (ADS)

    Heydt, Gerald; Briggs, Steve; Holcomb, Franklin; Edgar, Daiva

    1994-09-01

    Uninterruptible power supplies (UPS's) are used to provide power to sensitive and critical loads when the commercial supply has been interrupted. These loads may be nonlinear, which in the military often includes communications equipment, adjustable speed drives, fluorescent lighting, and mainframe and small computers. Most electrical characteristics of UPS's are not currently subject to codes and standards, and there are no military specifications for UPS's. Existing standards assume that UPS's will be operated with linear loads. Since most UPS systems are operated with nonlinear loads, there is concern that UPSs will suffer degraded performance or failure when operated with these loads. This work developed a test methodology by which UPS systems can be tested and their susceptibility to nonlinear loads quantified. The tests measure load transfer, efficiency, heating, load support, voltage regulation, and isolation. Several commercially available UPS systems are recommended for testing.

  2. Load Frequency Control by use of a Number of Both Heat Pump Water Heaters and Electric Vehicles in Power System with a Large Integration of Renewable Energy Sources

    NASA Astrophysics Data System (ADS)

    Masuta, Taisuke; Shimizu, Koichiro; Yokoyama, Akihiko

    In Japan, from the viewpoints of global warming countermeasures and energy security, it is expected to establish a smart grid as a power system into which a large amount of generation from renewable energy sources such as wind power generation and photovoltaic generation can be installed. Measures for the power system stability and reliability are necessary because a large integration of these renewable energy sources causes some problems in power systems, e.g. frequency fluctuation and distribution voltage rise, and Battery Energy Storage System (BESS) is one of effective solutions to these problems. Due to a high cost of the BESS, our research group has studied an application of controllable loads such as Heat Pump Water Heater (HPWH) and Electric Vehicle (EV) to the power system control for reduction of the required capacity of BESS. This paper proposes a new coordinated Load Frequency Control (LFC) method for the conventional power plants, the BESS, the HPWHs, and the EVs. The performance of the proposed LFC method is evaluated by the numerical simulations conducted on a power system model with a large integration of wind power generation and photovoltaic generation.

  3. Power systems

    NASA Astrophysics Data System (ADS)

    Kaplan, G.

    1982-01-01

    Significant events in current, prototype, and experimental utility power generating systems in 1981 are reviewed. The acceleration of licensing and the renewal of plans for reprocessing of fuel for nuclear power plants are discussed, including the rise of French reactor-produced electricity to over 40% of the country's electrical output. A 4.5 MW fuel cell neared completion in New York City, while three 2.5 MW NASA-designed windpowered generators began producing power in the state of Washington. Static bar compensators, nonflammable-liquid cooled power transformers, and ZnO surge arrestors were used by utilities for the first time, and the integration of a coal gasifier-combined cycle power plant approached the planning phase. An MHD generator was run for 1000 hours and produced 50-60 kWe, while a 20 MVA superconducting generator was readied for testing.

  4. Comparison of Wind Power and Load Forecasting Error Distributions: Preprint

    SciTech Connect

    Hodge, B. M.; Florita, A.; Orwig, K.; Lew, D.; Milligan, M.

    2012-07-01

    The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent System Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.

  5. Wireless power transfer system

    DOEpatents

    Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron

    2016-02-23

    A system includes a first stage of an inductive power transfer system with an LCL load resonant converter with a switching section, an LCL tuning circuit, and a primary receiver pad. The IPT system includes a second stage with a secondary receiver pad, a secondary resonant circuit, a secondary rectification circuit, and a secondary decoupling converter. The secondary receiver pad connects to the secondary resonant circuit. The secondary resonant circuit connects to the secondary rectification circuit. The secondary rectification circuit connects to the secondary decoupling converter. The second stage connects to a load. The load includes an energy storage element. The second stage and load are located on a vehicle and the first stage is located at a fixed location. The primary receiver pad wirelessly transfers power to the secondary receiver pad across a gap when the vehicle positions the secondary receiver pad with respect to the primary receiver pad.

  6. Shuttle car loading system

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr. (Inventor)

    1985-01-01

    A system is described for loading newly mined material such as coal, into a shuttle car, at a location near the mine face where there is only a limited height available for a loading system. The system includes a storage bin having several telescoping bin sections and a shuttle car having a bottom wall that can move under the bin. With the bin in an extended position and filled with coal the bin sections can be telescoped to allow the coal to drop out of the bin sections and into the shuttle car, to quickly load the car. The bin sections can then be extended, so they can be slowly filled with more while waiting another shuttle car.

  7. A PWM Buck Converter With Load-Adaptive Power Transistor Scaling Scheme Using Analog-Digital Hybrid Control for High Energy Efficiency in Implantable Biomedical Systems.

    PubMed

    Park, Sung-Yun; Cho, Jihyun; Lee, Kyuseok; Yoon, Euisik

    2015-12-01

    We report a pulse width modulation (PWM) buck converter that is able to achieve a power conversion efficiency (PCE) of > 80% in light loads 100 μA) for implantable biomedical systems. In order to achieve a high PCE for the given light loads, the buck converter adaptively reconfigures the size of power PMOS and NMOS transistors and their gate drivers in accordance with load currents, while operating at a fixed frequency of 1 MHz. The buck converter employs the analog-digital hybrid control scheme for coarse/fine adjustment of power transistors. The coarse digital control generates an approximate duty cycle necessary for driving a given load and selects an appropriate width of power transistors to minimize redundant power dissipation. The fine analog control provides the final tuning of the duty cycle to compensate for the error from the coarse digital control. The mode switching between the analog and digital controls is accomplished by a mode arbiter which estimates the average of duty cycles for the given load condition from limit cycle oscillations (LCO) induced by coarse adjustment. The fabricated buck converter achieved a peak efficiency of 86.3% at 1.4 mA and > 80% efficiency for a wide range of load conditions from 45 μA to 4.1 mA, while generating 1 V output from 2.5-3.3 V supply. The converter occupies 0.375 mm(2) in 0.18 μm CMOS processes and requires two external components: 1.2 μF capacitor and 6.8 μH inductor.

  8. Modified DSTATCOM Topology with Reduced DC Link Voltage for Reactive and Harmonic Power Compensation of Unbalanced Nonlinear Load in Distribution System

    NASA Astrophysics Data System (ADS)

    Geddada, Nagesh; Karanki, Srinivas B.; Mishra, Mahesh K.

    2014-06-01

    This paper proposes a modified four-leg distribution static compensator (DSTATCOM) topology for compensation of unbalanced and nonlinear loads in three-phase four-wire distribution system. DSTATCOM, connected in parallel to the load, supplies reactive and harmonic powers demanded by unbalanced nonlinear loads. In this proposed topology, the voltage source inverter (VSI) of DSTATCOM is connected to point of common coupling (point of interconnection of source, load, DSTATCOM) through interface inductor and series capacitance, unlike the conventional topology which consists of interface inductor alone. Load compensation with a lower value of input DC link voltage of VSI is possible in this modified topology compared to conventional topology. A comparative study on modified and conventional topologies in terms of voltage rating of inverter power switches, switching losses in VSI and power rating of input DC capacitor of VSI is presented. The detailed design aspects of DC link capacitor and interface series capacitor are also presented. The reference filter currents are generated using instantaneous symmetrical component theory and are tracked using hysteresis current control technique. A detailed simulation study is carried out, to compare the compensation performances of conventional, modified topologies using PSCAD simulator and experimental studies are done to validate the simulation results.

  9. Optimal load distribution between units in a power plant.

    PubMed

    Bortoni, Edson C; Bastos, Guilherme S; Souza, Luiz E

    2007-10-01

    This paper presents a strategy for load distribution between the generating units in hydro power plants. The objective is to reach the maximum energy conversion efficiency for a given dispatched power. The developed tool employs a heuristic-based combinatorial optimization technique in conjunction with a set of system variables measurement allowing real-time load sharing. The developed equipment is used to give online energy conversion efficiency from each unit of the power plant. No specific previous information about the efficiency of system components is required. Simulation results of the proposed optimization technique when applied to typical hydro power plant data are presented.

  10. Loads for pulsed power cylindrical implosion experiments

    SciTech Connect

    Anderson, W.E.; Armijo, E.V.; Barthell, B.L.; Bartos, J.J.; Bush, H.; Foreman, L.R.; Garcia, F.P.; Gobby, P.L.; Gomez, V.M.; Gurule, V.A.

    1994-07-01

    Pulse power can be used to generate high energy density conditions in convergent hollow cylindrical geometry through the use of appropriate electrode configuration and cylindrical loads. Cylindrically symmetric experiments are conducted with the Pegasus-H inductive store, capacitor energized pulse power facility at Los Alamos using both precision machined cylindrical liner loads and low mass vapor deposited cylindrical foil loads. The liner experiments investigate solid density hydrodynamic topics. Foil loads vaporize from Joule heating to generate an imploding cylindrical plasma which can be used to simulate some fluxes associated with fusion energy processes. Similar experiments are conducted with {open_quotes}Procyon{close_quotes} inductive store pulse power assemblies energized by explosively driven magnetic flux compression.

  11. Common source-multiple load vs. separate source-individual load photovoltaic system

    NASA Technical Reports Server (NTRS)

    Appelbaum, Joseph

    1989-01-01

    A comparison of system performance is made for two possible system setups: (1) individual loads powered by separate solar cell sources; and (2) multiple loads powered by a common solar cell source. A proof for resistive loads is given that shows the advantage of a common source over a separate source photovoltaic system for a large range of loads. For identical loads, both systems perform the same.

  12. Current Limiting and Recovery Characteristics Under Load of Transformer Type SFCL with Rewound Structure Using BSCCO Wire in Model Power System

    NASA Astrophysics Data System (ADS)

    Noda, Sho; Oda, Sayaka; Mori, Masato; Hattori, Keisuke; Baba, Jumpei; Shirai, Yasuyuki

    We have proposed new design of a transformer type SFCL with primary and secondary superconducting coils which has rewound structure. For not so large fault current, the proposed SFCL limits the current by the inductive component by the normal transition of the flux shielding coil (secondary), and for larger fault current, it can give the resistive component additively by the normal transition of the primary coil. The recovery characteristics under load condition and repetitive limiting operation were experimentally investigated in a laboratory scale power system. The SFCL limited twice repetitive faults current and recovered quickly under load condition.

  13. Autonomous power expert system

    NASA Technical Reports Server (NTRS)

    Ringer, Mark J.; Quinn, Todd M.

    1990-01-01

    The goal of the Autonomous Power System (APS) program is to develop and apply intelligent problem solving and control technologies to the Space Station Freedom Electrical Power Systems (SSF/EPS). The objectives of the program are to establish artificial intelligence/expert system technology paths, to create knowledge based tools with advanced human-operator interfaces, and to integrate and interface knowledge-based and conventional control schemes. This program is being developed at the NASA-Lewis. The APS Brassboard represents a subset of a 20 KHz Space Station Power Management And Distribution (PMAD) testbed. A distributed control scheme is used to manage multiple levels of computers and switchgear. The brassboard is comprised of a set of intelligent switchgear used to effectively switch power from the sources to the loads. The Autonomous Power Expert System (APEX) portion of the APS program integrates a knowledge based fault diagnostic system, a power resource scheduler, and an interface to the APS Brassboard. The system includes knowledge bases for system diagnostics, fault detection and isolation, and recommended actions. The scheduler autonomously assigns start times to the attached loads based on temporal and power constraints. The scheduler is able to work in a near real time environment for both scheduling and dynamic replanning.

  14. A distributed model predictive control based load frequency control scheme for multi-area interconnected power system using discrete-time Laguerre functions.

    PubMed

    Zheng, Yang; Zhou, Jianzhong; Xu, Yanhe; Zhang, Yuncheng; Qian, Zhongdong

    2017-03-23

    This paper proposes a distributed model predictive control based load frequency control (MPC-LFC) scheme to improve control performances in the frequency regulation of power system. In order to reduce the computational burden in the rolling optimization with a sufficiently large prediction horizon, the orthonormal Laguerre functions are utilized to approximate the predicted control trajectory. The closed-loop stability of the proposed MPC scheme is achieved by adding a terminal equality constraint to the online quadratic optimization and taking the cost function as the Lyapunov function. Furthermore, the treatments of some typical constraints in load frequency control have been studied based on the specific Laguerre-based formulations. Simulations have been conducted in two different interconnected power systems to validate the effectiveness of the proposed distributed MPC-LFC as well as its superiority over the comparative methods.

  15. Automated Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Thomason, Cindy; Anderson, Paul M.; Martin, James A.

    1990-01-01

    Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

  16. Design and analysis of tilt integral derivative controller with filter for load frequency control of multi-area interconnected power systems.

    PubMed

    Kumar Sahu, Rabindra; Panda, Sidhartha; Biswal, Ashutosh; Chandra Sekhar, G T

    2016-03-01

    In this paper, a novel Tilt Integral Derivative controller with Filter (TIDF) is proposed for Load Frequency Control (LFC) of multi-area power systems. Initially, a two-area power system is considered and the parameters of the TIDF controller are optimized using Differential Evolution (DE) algorithm employing an Integral of Time multiplied Absolute Error (ITAE) criterion. The superiority of the proposed approach is demonstrated by comparing the results with some recently published heuristic approaches such as Firefly Algorithm (FA), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) optimized PID controllers for the same interconnected power system. Investigations reveal that proposed TIDF controllers provide better dynamic response compared to PID controller in terms of minimum undershoots and settling times of frequency as well as tie-line power deviations following a disturbance. The proposed approach is also extended to two widely used three area test systems considering nonlinearities such as Generation Rate Constraint (GRC) and Governor Dead Band (GDB). To improve the performance of the system, a Thyristor Controlled Series Compensator (TCSC) is also considered and the performance of TIDF controller in presence of TCSC is investigated. It is observed that system performance improves with the inclusion of TCSC. Finally, sensitivity analysis is carried out to test the robustness of the proposed controller by varying the system parameters, operating condition and load pattern. It is observed that the proposed controllers are robust and perform satisfactorily with variations in operating condition, system parameters and load pattern. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Designing divertor targets for uniform power load

    NASA Astrophysics Data System (ADS)

    Dekeyser, W.; Reiter, D.; Baelmans, M.

    2015-08-01

    Divertor design for next step fusion reactors heavily relies on 2D edge plasma modeling with codes as e.g. B2-EIRENE. While these codes are typically used in a design-by-analysis approach, in previous work we have shown that divertor design can alternatively be posed as a mathematical optimization problem, and solved very efficiently using adjoint methods adapted from computational aerodynamics. This approach has been applied successfully to divertor target shape design for more uniform power load. In this paper, the concept is further extended to include all contributions to the target power load, with particular focus on radiation. In a simplified test problem, we show the potential benefits of fully including the radiation load in the design cycle as compared to only assessing this load in a post-processing step.

  18. Load Frequency Control of a Two-Area Thermal-Hybrid Power System Using a Novel Quasi-Opposition Harmony Search Algorithm

    NASA Astrophysics Data System (ADS)

    Mahto, Tarkeshwar; Mukherjee, V.

    2016-09-01

    In the present work, a two-area thermal-hybrid interconnected power system, consisting of a thermal unit in one area and a hybrid wind-diesel unit in other area is considered. Capacitive energy storage (CES) and CES with static synchronous series compensator (SSSC) are connected to the studied two-area model to compensate for varying load demand, intermittent output power and area frequency oscillation. A novel quasi-opposition harmony search (QOHS) algorithm is proposed and applied to tune the various tunable parameters of the studied power system model. Simulation study reveals that inclusion of CES unit in both the areas yields superb damping performance for frequency and tie-line power deviation. From the simulation results it is further revealed that inclusion of SSSC is not viable from both technical as well as economical point of view as no considerable improvement in transient performance is noted with its inclusion in the tie-line of the studied power system model. The results presented in this paper demonstrate the potential of the proposed QOHS algorithm and show its effectiveness and robustness for solving frequency and power drift problems of the studied power systems. Binary coded genetic algorithm is taken for sake of comparison.

  19. Blade Pitch Angle Control and its Capacity Reduction Effect on Battery for Load Frequency Control in Power System with a Large Capacity of Wind Power Generation

    NASA Astrophysics Data System (ADS)

    Nishizaki, Yasushi; Irie, Hiroshi; Yokoyama, Akihiko; Tada, Yasuyuki

    Considering interconnection of a large-capacity of wind power generation to the utility grid, it is of great concern that its output power fluctuation has adverse influences, e.g. frequency fluctuation. There have so far been some research works on installation of battery energy storage systems (BESS), as a solution of these problems. However, owing to very high cost of the BESS, its capacity should be as small as possible. In this paper, not only the installation of the BESS as one of measures of suppressing the frequency fluctuation caused by wind power generation, but also blade pitch angle control for blunting the output power of wind turbine generators (WTGs) is also considered. This paper proposes a coordinated control method of the BESS and the blade pitch angle, and evaluates reduction of the capacity of the BESS and the power generation loss caused by blunting the output power which should be originally generated by WTGs.

  20. Electric-Power System Simulator

    NASA Technical Reports Server (NTRS)

    Caldwell, R. W.; Grumm, R. L.; Biedebach, B. L.

    1984-01-01

    Shows different combinations of generation, storage, and load components: display, video monitor with keyboard input to microprocessor, and video monitor for display of load curves and power generation. Planning tool for electric utilities, regulatory agencies, and laymen in understanding basics of electric-power systems operation.

  1. Application of expert system to load composition rate estimation algorithm

    SciTech Connect

    Lim, J.Y.; Kim, J.H.; Kim, J.O.; Singh, C.

    1999-08-01

    A load model is needed for the power system analysis including load flow and stability studies. The load model representation needs the load composition rate indicating the portion of several typical load groups. This paper proposes a refined load composition rate estimation algorithm with input data which are relative coefficients, limit values, and the energy portion of load groups. An expert system is constructed with the consideration of the uncertainty of input data. The load composition rates in several customers in the power system are obtained and the results of case studies show that a reasonable load composition rate is achieved.

  2. A software system used for load distribution at a combined heat and power plant with the complex mix of the equipment and complex schemes of heat and electric power supply

    NASA Astrophysics Data System (ADS)

    Makarch'yan, V. A.; Chernyaev, A. N.; Andryushin, A. V.; Pechenkin, S. P.; Lisitsa, V. I.; Logvinov, E. I.; Molchanov, A. Yu.

    2013-05-01

    The authors describe various approaches to construction of an algorithm for the solution of the problem of load distribution at a combined heat and power (CHP) plant with the complex mix of the equipment and complex schemes of heat and electrical energy supply on the basis of which the software system has been developed. Methods of obtaining energy characteristics of the equipment used for solving the problem of load distribution were studied. The results of the implementation of the software system for load distribution at the CHP-23 plant belonging to OAO Mosenergo are given. Realization of recommendations on maintaining an operational mode of the equipment with due regard for its optimal loading makes it possible to obtain fuel savings of up to 1%.

  3. Overview of High Power Vacuum Dry RF Load Designs

    SciTech Connect

    Krasnykh, Anatoly

    2015-08-27

    A specific feature of RF linacs based on the pulsed traveling wave (TW) mode of operation is that only a portion of the RF energy is used for the beam acceleration. The residual RF energy has to be terminated into an RF load. Higher accelerating gradients require higher RF sources and RF loads, which can stably terminate the residual RF power. RF feeders (from the RF source though the accelerating section to the load) are vacuumed to transmit multi-megawatt high power RF. This overview will outline vacuumed RF loads only. A common method to terminate multi-MW RF power is to use circulated water (or other liquid) as an absorbing medium. A solid dielectric interface (a high quality ceramic) is required to separate vacuum and liquid RF absorber mediums. Using such RF load approaches in TW linacs is troubling because there is a fragile ceramic window barrier and a failure could become catastrophic for linac vacuum and RF systems. Traditional loads comprising of a ceramic disk have limited peak and average power handling capability and are therefore not suitable for high gradient TW linacs. This overview will focus on ''vacuum dry'' or ''all-metal'' loads that do not employ any dielectric interface between vacuum and absorber. The first prototype is an original design of RF loads for the Stanford Two-Mile Accelerator.

  4. Advanced Power Conditioning System

    NASA Technical Reports Server (NTRS)

    Johnson, N. L.

    1971-01-01

    The second portion of the advanced power conditioning system development program is reported. Five 100-watt parallel power stages with majority-vote-logic feedback-regulator were breadboarded and tested to the design goals. The input voltage range was 22.1 to 57.4 volts at loads from zero to 500 watts. The maximum input ripple current was 200 mA pk-pk (not including spikes) at 511 watts load; the output voltage was 56V dc with a maximum change of 0.89 volts for all variations of line, load, and temperature; the maximum output ripple was 320 mV pk-pk at 512 watts load (dependent on filter capacitance value); the maximum efficiency was 93.9% at 212 watts and 50V dc input; the minimum efficiency was 87.2% at 80-watt load and 50V dc input; the efficiency was above 90% from 102 watts to 372 watts; the maximum excursion for an 80-watt load change was 2.1 volts with a recovery time of 7 milliseconds; and the unit performed within regulation limits from -20 C to +85 C. During the test sequence, margin tests and failure mode tests were run with no resulting degradation in performance.

  5. Control circuit maintains unity power factor of reactive load

    NASA Technical Reports Server (NTRS)

    Kramer, M.; Martinage, L. H.

    1966-01-01

    Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.

  6. Offshore tanker loading system

    SciTech Connect

    Baan, J. de; Heijst, W.J. van.

    1994-01-04

    The present invention relates to an improved flexible loading system which provides fluid communication between a subsea pipeline and a surface vessel including a hose extending from the subsea pipeline to a first buoyancy tank, a second hose extending from the first buoyancy tank to a central buoyancy tank, a second buoyancy tank, means connecting said second buoyancy tank to the sea floor and to the central buoyancy tank whereby the forces exerted on said central buoyant tank by said second hose and said connecting means are balanced to cause said central buoyancy tank to maintain a preselected position, a riser section extending upwardly from said central buoyancy tank and means on the upper termination for engagement by a vessel on the surface to raise said upper termination onto the vessel to complete the communication for moving fluids between the subsea pipeline and the vessel. In one form the means for connecting between the sea floor to the second buoyancy tank includes an anchor on the sea floor and lines extending from the anchor to the second buoyancy tank and from the second buoyancy tank to the central buoyancy tank. In another form of the invention the means for connecting is a third hose extending from a second subsea pipeline to the second buoyancy tank and a fourth hose extending from the second buoyancy tank to the central buoyancy tank. The central buoyancy tank is preferred to be maintained at a level below the water surface which allows full movement of the vessel while connected to the riser section. A swivel may be positioned in the riser section and a pressure relief system may be included in the loading system to protect it from sudden excess pressures. 17 figs.

  7. Simple power supply for power load controlled isoelectric focusing.

    PubMed

    Duša, Filip; Slais, Karel

    2014-04-01

    The power supply for IEF based on features of the Cockcroft-Walton voltage multiplier (CW VM) is described in this work. The article describes a design of the IEF power supply, its electric characteristics, and testing by IEF analysis. A circuit diagram of the power supply included two opposite charged branches (each consisting of four voltage doublers). The designed CW VM was powered by 230 V/50 Hz alternate current and it generated up to 5 kV and 90 mW at the output. Voltage and current characteristics of the power supply were measured by known load resistances in the range from 10 kΩ to 1 GΩ, which is a common resistance range for IEF strip geometry. Further, the power supply was tested by a separation of a model mixture of colored pI markers using a 175 × 3 × 0.5 mm focusing bed. Automatically limited power load enabled analysis of samples without previous optimization of the focusing voltage or electric current time courses according to sample composition. Moreover, the developed power supply did not produce any intrinsic heat and was easy to set up with cheap and commonly available parts.

  8. Data centers as dispatchable loads to harness stranded power

    DOE PAGES

    Kim, Kibaek; Yang, Fan; Zavala, Victor M.; ...

    2016-07-20

    Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast,more » optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.« less

  9. Data centers as dispatchable loads to harness stranded power

    SciTech Connect

    Kim, Kibaek; Yang, Fan; Zavala, Victor M.; Chien, Andrew A.

    2016-07-20

    Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast, optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.

  10. Load characteristics of high power sandwich piezoelectric ultrasonic transducers.

    PubMed

    Shuyu, Lin

    2005-03-01

    Based on the equivalent circuit theory, the load characteristics of high power piezoelectric ultrasonic sandwich transducers are studied. Two types of loads are studied. One is liquid load as in ultrasonic cleaning, and the other is solid load as in ultrasonic drilling and machining. The effect of load and structure of the transducer on the resonance frequency of the transducer is analyzed. It is shown that the effect of load on the resonance frequency of sandwich transducers with different structures is different. For liquid load as in ultrasonic cleaning, the effect of the load on the resonance frequency of the sandwich transducer with symmetrical structure is the largest. It is the smallest for the transducer with its displacement node in the back metal cylinder. For solid load as in ultrasonic drilling and machining, the effect of the load on the resonance frequency of the sandwich transducer with its displacement node in the front metal cylinder is the largest. It is also the smallest for the transducer with its displacement node in the back metal cylinder. On the other hand, for some applications, such as ultrasonic drilling, when the lateral dimension of the tool is much less than that of the transducer, its effect on the resonance frequency of the transducer is small. The conclusions are useful in designing vibrating systems for different ultrasonic applications.

  11. Automated Power Systems Management (APSM)

    NASA Technical Reports Server (NTRS)

    Bridgeforth, A. O.

    1981-01-01

    A breadboard power system incorporating autonomous functions of monitoring, fault detection and recovery, command and control was developed, tested and evaluated to demonstrate technology feasibility. Autonomous functions including switching of redundant power processing elements, individual load fault removal, and battery charge/discharge control were implemented by means of a distributed microcomputer system within the power subsystem. Three local microcomputers provide the monitoring, control and command function interfaces between the central power subsystem microcomputer and the power sources, power processing and power distribution elements. The central microcomputer is the interface between the local microcomputers and the spacecraft central computer or ground test equipment.

  12. Real power regulation for the utility power grid via responsive loads

    DOEpatents

    McIntyre, Timothy J [Knoxville, TN; Kirby, Brendan J [Knoxville, TN; Kisner, Roger A

    2009-05-19

    A system for dynamically managing an electrical power system that determines measures of performance and control criteria for the electric power system, collects at least one automatic generation control (AGC) input parameter to at least one AGC module and at least one automatic load control (ALC) input parameter to at least one ALC module, calculates AGC control signals and loads as resources (LAR) control signals in response to said measures of performance and control criteria, propagates AGC control signals to power generating units in response to control logic in AGC modules, and propagates LAR control signals to at least one LAR in response to control logic in ALC modules.

  13. 20-kW solar photovoltaic flat-panel power system for an uninterruptible power-system load in El Paso, Texas. Phase II. System fabrication. Final report October 1, 1979-May 31, 1981

    SciTech Connect

    Risser, V.V.

    1981-12-01

    The system plans, construction, integration and test, and performance evaluation are discussed for the photovoltaic power supply at the Newman Power Station in El Paso, Texas. The system consists of 64 parallel-connected panels, each panel containing nine series-connected photovoltaic modules. The system is connected, through power monitoring equipment, to an existing DC bus that supplies uninterruptible power to a computer that controls the power generating equipment. The site is described and possible environmental hazards are assessed. Site preparation and the installation of the photovoltaic panels, electrical cabling, and instrumentation subsystems are described. System testing includes initial system checkout, module performance test, control system test. A training program for operators and maintenance personnel is briefly described, including visual aids. Performance data collection and analysis are described, and actual data are compared with a computer simulation. System drawings are included. (LEW)

  14. Shunt regulation electric power system

    NASA Technical Reports Server (NTRS)

    Wright, W. H.; Bless, J. J. (Inventor)

    1971-01-01

    A regulated electric power system having load and return bus lines is described. A plurality of solar cells interconnected in a power supplying relationship and having a power shunt tap point electrically spaced from the bus lines is provided. A power dissipator is connected to the shunt tap point and provides for a controllable dissipation of excess energy supplied by the solar cells. A dissipation driver is coupled to the power dissipator and controls its conductance and dissipation and is also connected to the solar cells in a power taping relationship to derive operating power therefrom. An error signal generator is coupled to the load bus and to a reference signal generator to provide an error output signal which is representative of the difference between the electric parameters existing at the load bus and the reference signal generator. An error amplifier is coupled to the error signal generator and the dissipation driver to provide the driver with controlling signals.

  15. Automatic calorimetry system monitors RF power

    NASA Technical Reports Server (NTRS)

    Harness, B. W.; Heiberger, E. C.

    1969-01-01

    Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

  16. Controllable Bidirectional dc Power Sources For Large Loads

    NASA Technical Reports Server (NTRS)

    Tripp, John S.; Daniels, Taumi S.

    1995-01-01

    System redesigned for greater efficiency, durability, and controllability. Modern electronically controlled dc power sources proposed to supply currents to six electromagnets used to position aerodynamic test model in wind tunnel. Six-phase bridge rectifier supplies load with large current at voltage of commanded magnitude and polarity. Current-feedback circuit includes current-limiting feature giving some protection against overload.

  17. Aging and service wear of spring-loaded pressure relief valves used in safety-related systems at nuclear power plants

    SciTech Connect

    Staunton, R.H.; Cox, D.F.

    1995-03-01

    Spring-loaded pressure relief valves (PRVS) are used in some safety-related applications at nuclear power plants. In general, they are used in systems where, during accidents, pressures may rise to levels where pressure safety relief is required for protection of personnel, system piping, and components. This report documents a study of PRV aging and considers the severity and causes of service wear and how it is discovered and corrected in various systems, valve sizes, etc. Provided in this report are results of the examination of the recorded failures and identification of trends and relationships/correlations in the failures when all failure-related parameters are considered. Components that comprise a typical PRV, how those components fail, when they fail, and the current testing frequencies and methods are also presented in detail.

  18. Autonomous power system brassboard

    NASA Technical Reports Server (NTRS)

    Merolla, Anthony

    1992-01-01

    The Autonomous Power System (APS) brassboard is a 20 kHz power distribution system which has been developed at NASA Lewis Research Center, Cleveland, Ohio. The brassboard exists to provide a realistic hardware platform capable of testing artificially intelligent (AI) software. The brassboard's power circuit topology is based upon a Power Distribution Control Unit (PDCU), which is a subset of an advanced development 20 kHz electrical power system (EPS) testbed, originally designed for Space Station Freedom (SSF). The APS program is designed to demonstrate the application of intelligent software as a fault detection, isolation, and recovery methodology for space power systems. This report discusses both the hardware and software elements used to construct the present configuration of the brassboard. The brassboard power components are described. These include the solid-state switches (herein referred to as switchgear), transformers, sources, and loads. Closely linked to this power portion of the brassboard is the first level of embedded control. Hardware used to implement this control and its associated software is discussed. An Ada software program, developed by Lewis Research Center's Space Station Freedom Directorate for their 20 kHz testbed, is used to control the brassboard's switchgear, as well as monitor key brassboard parameters through sensors located within these switches. The Ada code is downloaded from a PC/AT, and is resident within the 8086 microprocessor-based embedded controllers. The PC/AT is also used for smart terminal emulation, capable of controlling the switchgear as well as displaying data from them. Intelligent control is provided through use of a T1 Explorer and the Autonomous Power Expert (APEX) LISP software. Real-time load scheduling is implemented through use of a 'C' program-based scheduling engine. The methods of communication between these computers and the brassboard are explored. In order to evaluate the features of both the

  19. Autonomous power system brassboard

    NASA Astrophysics Data System (ADS)

    Merolla, Anthony

    1992-10-01

    The Autonomous Power System (APS) brassboard is a 20 kHz power distribution system which has been developed at NASA Lewis Research Center, Cleveland, Ohio. The brassboard exists to provide a realistic hardware platform capable of testing artificially intelligent (AI) software. The brassboard's power circuit topology is based upon a Power Distribution Control Unit (PDCU), which is a subset of an advanced development 20 kHz electrical power system (EPS) testbed, originally designed for Space Station Freedom (SSF). The APS program is designed to demonstrate the application of intelligent software as a fault detection, isolation, and recovery methodology for space power systems. This report discusses both the hardware and software elements used to construct the present configuration of the brassboard. The brassboard power components are described. These include the solid-state switches (herein referred to as switchgear), transformers, sources, and loads. Closely linked to this power portion of the brassboard is the first level of embedded control. Hardware used to implement this control and its associated software is discussed. An Ada software program, developed by Lewis Research Center's Space Station Freedom Directorate for their 20 kHz testbed, is used to control the brassboard's switchgear, as well as monitor key brassboard parameters through sensors located within these switches. The Ada code is downloaded from a PC/AT, and is resident within the 8086 microprocessor-based embedded controllers. The PC/AT is also used for smart terminal emulation, capable of controlling the switchgear as well as displaying data from them. Intelligent control is provided through use of a T1 Explorer and the Autonomous Power Expert (APEX) LISP software. Real-time load scheduling is implemented through use of a 'C' program-based scheduling engine. The methods of communication between these computers and the brassboard are explored. In order to evaluate the features of both the

  20. Advanced Solar Power Systems

    NASA Technical Reports Server (NTRS)

    Atkinson, J. H.; Hobgood, J. M.

    1984-01-01

    The Advanced Solar Power System (ASPS) concentrator uses a technically sophisticated design and extensive tooling to produce very efficient (80 to 90%) and versatile energy supply equipment which is inexpensive to manufacture and requires little maintenance. The advanced optical design has two 10th order, generalized aspheric surfaces in a Cassegrainian configuration which gives outstanding performance and is relatively insensitive to temperature changes and wind loading. Manufacturing tolerances also have been achieved. The key to the ASPS is the direct absorption of concentrated sunlight in the working fluid by radiative transfers in a black body cavity. The basic ASPS design concepts, efficiency, optical system, and tracking and focusing controls are described.

  1. Low reflectance high power RF load

    DOEpatents

    Ives, R. Lawrence; Mizuhara, Yosuke M.

    2016-02-02

    A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

  2. Expert system requirements for power system restoration

    SciTech Connect

    Adibi, M.M. ); Kafka, R.J. ); Milanicz, D.P. )

    1994-08-01

    This paper is one of series presented on behalf of the System Operation Subcommittee with the intent of focusing industry attention on power system restoration. Expert systems are being considered for restoring bulk power supplies. In general, there are three restoration periods following a major power disturbance: establishment of initial sources of power, re-integration of a skeleton of the bulk power supply, and minimization of the unserved loads. Expert systems together with analytical tools have the potential of addressing the restoration procedures over these three periods. This paper describes the expert system requirements from the point of view of the practicing power engineers with emphasis placed on the initial power sources and requirements. The paper draws on the previous reports by the Power System Restoration Working Group.

  3. Remote Area Power Supply (RAPS) load and resource profiles.

    SciTech Connect

    Giles, Lauren; Skolnik, Edward G.; Marchionini, Brian; Fall, Ndeye K.

    2007-07-01

    In 1997, an international team interested in the development of Remote Area Power Supply (RAPS) systems for rural electrification projects around the world was organized by the International Lead Zinc Research Organization (ILZRO) with the support of Sandia National Laboratories (SNL). The team focused on defining load and resource profiles for RAPS systems. They identified single family homes, small communities, and villages as candidates for RAPS applications, and defined several different size/power requirements for each. Based on renewable energy and resource data, the team devised a ''strawman'' series of load profiles. A RAPS system typically consists of a renewable and/or conventional generator, power conversion equipment, and a battery. The purpose of this report is to present data and information on insolation levels and load requirements for ''typical'' homes, small communities, and larger villages around the world in order to facilitate the development of robust design practices for RAPS systems, and especially for the storage battery component. These systems could have significant impact on areas of the world that would otherwise not be served by conventional electrical grids.

  4. Switching power pulse system

    DOEpatents

    Aaland, K.

    1983-08-09

    A switching system for delivering pulses of power from a source to a load using a storage capacitor charged through a rectifier, and maintained charged to a reference voltage level by a transistor switch and voltage comparator. A thyristor is triggered to discharge the storage capacitor through a saturable reactor and fractional turn saturable transformer having a secondary to primary turn ratio N of n:l/n = n[sup 2]. The saturable reactor functions as a soaker'' while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor charges, and then switches to a low impedance state to dump the charge of the storage capacitor into the load through the coupling capacitor. The transformer is comprised of a multilayer core having two secondary windings tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe for a linear particle accelerator and capacitance of a pulse forming network. To hold off discharge of the capacitance until it is fully charged, a saturable core is provided around the resistive beampipe to isolate the beampipe from the capacitance until it is fully charged. 5 figs.

  5. Effect of hydraulic loading rate on pollutant removal efficiency in subsurface infiltration system under intermittent operation and micro-power aeration.

    PubMed

    Yang, Yongqiang; Zhan, Xuan; Wu, Shijun; Kang, Mingliang; Guo, Jianan; Chen, Fanrong

    2016-04-01

    The low hydraulic loading rate (HLR) greatly restricts the wide application of subsurface wastewater infiltration system (SWIS) in densely populated areas. To increase the HLR, an innovative SWIS was developed using cyclic operation mode. In each cycle, a wastewater feeding period is followed by a drying period, in which the aeration is conducted by a medium-pressure fan. Results indicated that the removal rate of TOC and NH4(+)-N were more than 85% at HLR of 0.5m(3)/m(2)d, whereas the TN removal rate was lower than 20%, indicating that the aeration was efficient and denitrification process was largely limited in the SWIS. When HLR decreased from 0.5 to 0.2m(3)/m(2)d, the pollutant removal efficiency enhanced slightly except for TN. Overall, the intermittent operation and micro-power aeration, combined with shunting the pollutant loading were really helpful for SWIS to achieve higher HLR, which offers a reference for the design of innovative SWIS. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Pluto Express power system architecture

    SciTech Connect

    Carr, G.A.

    1996-12-31

    The Pluto Express power system must answer the challenge of the next generation spacecraft by reducing its power, mass and volume envelopes. Technology developed by the New Millennium Program will enable the power system to meet the stringent requirements for the Pluto Express mission without exceeding the spacecraft mass and volume budgets. Traditionally, there has been an increasing trend of the percentage of mass of the power system electronics with respect to the total spacecraft mass. With all of the previous technology focus on high density digital packaging, the power system electronics have not been keeping pace forcing the spacecraft to absorb a relative increase in the power system mass. The increasing trend can be reversed by using mixed signal ASICs and high density multi-chip-module (MCM) packaging techniques validated by the New Millennium Program. As the size of the spacecraft shrinks, the power system electronics must become tightly integrated with the spacecraft loads. The power system architecture needs the flexibility to accommodate the specific load requirements without sacrificing the capability for growth or reduction as the spacecraft requirements change throughout the development. Modularity is a key requirement that will reduce the overall power system cost. Although the focus has been on shrinking the power system volume and mass, the efficiency and functionality cannot be ignored. Increased efficiency and functionality will only enhance the power systems capability to reduce spacecraft power requirements. The combination of the New Millennium packaging technologies with the Pluto Express power system architecture will produce a product with the capability to meet a wide range of mission profiles while reducing system development costs.

  7. Speed And Power Control Of An Engine By Modulation Of The Load Torque

    DOEpatents

    Ziph, Benjamin; Strodtman, Scott; Rose, Thomas K

    1999-01-26

    A system and method of speed and power control for an engine in which speed and power of the engine is controlled by modulation of the load torque. The load torque is manipulated in order to cause engine speed, and hence power to be changed. To accomplish such control, the load torque undergoes a temporary excursion in the opposite direction of the desired speed and power change. The engine and the driven equipment will accelerate or decelerate accordingly as the load torque is decreased or increased, relative to the essentially fixed or constant engine torque. As the engine accelerates or decelerates, its power increases or decreases in proportion.

  8. A Proposal of a Load/Source Simulator Based on the UPFC (Unified Power Flow Controller) and Operating Performance of a 200-V, 10-kW Laboratory System

    NASA Astrophysics Data System (ADS)

    Taguchi, Yoshiaki; Akagi, Hirofumi

    The main purpose of a load/source simulator is to imitate an actual load/source in terms of power or current. This paper proposes a novel load/source simulator based on the unified power flow controller that is one of FACTS devices. This system takes the following prominent advantage: The converter volt-ampere rating required for the proposed system is much smaller than that for a conventional system based on a BTB (Back-To-Back) converter. Experimental results obtained from a 200-V, 10-kW laboratory system confirm the viability and effectiveness of the system. This paper also discusses the control method theoretically, and analyzes a voltage fluctuation of the dc link, thus leading to system design.

  9. Loading spout and wheel for 1913 power grain shovel inside ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Loading spout and wheel for 1913 power grain shovel inside covered hopper loading dock at railroad level looking west - Stewart Company Grain Elevator, 16 West Carson Street, Pittsburgh, Allegheny County, PA

  10. IPLS: Interactive Pallet Loading System.

    DTIC Science & Technology

    1981-06-01

    AD-AI01 410 FLOR IDA UNIV GAINESVILLE DEPT OF INDUSTRIAL AND SYS--ETC F/6 15/5 IPLS. INTERACTIVE PALLET LOADING SYSTEM.(U) .JN 81 T J HODGSON. N0OCIA...76-C 0096 UNCLASSIFIEDRR69L * unuuuu L~EhEEEE / IPL SINTERACTIVE PALLET LOADING SYSTEM Research Report No. 8]-9 by Thorn J. Hodgson June, 1981...COVEREo IPLS: INTERACTIVE PALLET LOADING SyS Technical / j ’.l e P a t . | - f F O M IN G O R G . R E P O R T N U M B E R--81-9 7. AuTmo, .. s

  11. Potential for solar-powered base-load capacity

    NASA Astrophysics Data System (ADS)

    Stoll, Brady; Deinert, Mark

    2013-04-01

    In 2010 nuclear power accounted for 27% of electricity production in Japan. The March 2011 disaster at the Fukushima Daiichi power station resulted in the closure of all of Japans nuclear power plants and it remains an open question as to how many will reopen. Even before the loss of nuclear capacity there were efforts in Japan to foster the use of renewable energy, including large-scale solar power. Nuclear power plants in Japan operated beyond base load with excess energy being stored in large scale pumped hydroelectric storage systems. Here we show how coupling these storage systems to rooftop solar systems in Tokyo could compensate for the loss of nuclear power. Data from a study of rooftop space, and a 34-year data set of average daily irradiance in the Tokyo metropolitan area were used. If current generation PV systems were placed on the available rooftop space in greater Tokyo, this coupled system could provide for 20% of Toyo's nuclear capacity with a capacity factor of 0.99. Using pumped hydroelectric storage with six times this rooftop area could completely provide for TEPCO's nuclear capacity with a capacity factor of 0.98.

  12. Short-term load forecasting study of wind power based on Elman neural network

    NASA Astrophysics Data System (ADS)

    Tian, Xinran; Yu, Jing; Long, Teng; Liu, Jicheng

    2017-01-01

    Since wind power has intermittent, irregular and volatility nature, improving load forecasting accuracy of wind power has significant influence on controlling wind system and guarantees stable operation of power grids. This paper constructed the wind farm loading forecasting in short-term based on Elman neural network, and made a numerical example analysis. . Examples show that, using input delayed of feedback Elman neural network, can reflect the inherent laws of wind load operation better, so as to present a new idea for short-term load forecasting of wind power.

  13. Soldier System Power Sources

    DTIC Science & Technology

    2006-12-31

    capability 21 Photovoltaic Power Sources 23 Maximum Power Tracking in Solar Arrays 23 Optimum Configuration of Solar Array for Enhanced Power Generation...Sources", IEEE Transactions on Power Elec- tronics, vol. 20, No. 1, pp. 244-253, Jan. 2005. 9. S. Liu, R. Dougal, E. Solodovnik, "Maximum Power Tracking and...eguate FRetulat Fig. 5.5. Flow chart of control algorithm. 22 Soldier System Power Sources Final Project Report PHOTOVOLTAIC POWER SOURCES MAXIMUM POWER

  14. TOPEX electrical power system

    NASA Technical Reports Server (NTRS)

    Chetty, P. R. K.; Roufberg, Lew; Costogue, Ernest

    1991-01-01

    The TOPEX mission requirements which impact the power requirements and analyses are presented. A description of the electrical power system (EPS), including energy management and battery charging methods that were conceived and developed to meet the identified satellite requirements, is included. Analysis of the TOPEX EPS confirms that all of its electrical performance and reliability requirements have been met. The TOPEX EPS employs the flight-proven modular power system (MPS) which is part of the Multimission Modular Spacecraft and provides high reliability, abbreviated development effort and schedule, and low cost. An energy balance equation, unique to TOPEX, has been derived to confirm that the batteries will be completely recharged following each eclipse, under worst-case conditions. TOPEX uses three NASA Standard 50AH Ni-Cd batteries, each with 22 cells in series. The MPS contains battery charge control and protection based on measurements of battery currents, voltages, temperatures, and computed depth-of-discharge. In case of impending battery depletion, the MPS automatically implements load shedding.

  15. TOPEX electrical power system

    NASA Technical Reports Server (NTRS)

    Chetty, P. R. K.; Roufberg, Lew; Costogue, Ernest

    1991-01-01

    The TOPEX mission requirements which impact the power requirements and analyses are presented. A description of the electrical power system (EPS), including energy management and battery charging methods that were conceived and developed to meet the identified satellite requirements, is included. Analysis of the TOPEX EPS confirms that all of its electrical performance and reliability requirements have been met. The TOPEX EPS employs the flight-proven modular power system (MPS) which is part of the Multimission Modular Spacecraft and provides high reliability, abbreviated development effort and schedule, and low cost. An energy balance equation, unique to TOPEX, has been derived to confirm that the batteries will be completely recharged following each eclipse, under worst-case conditions. TOPEX uses three NASA Standard 50AH Ni-Cd batteries, each with 22 cells in series. The MPS contains battery charge control and protection based on measurements of battery currents, voltages, temperatures, and computed depth-of-discharge. In case of impending battery depletion, the MPS automatically implements load shedding.

  16. Load measurement system with load cell lock-out mechanism

    NASA Technical Reports Server (NTRS)

    Le, Thang; Carroll, Monty; Liu, Jonathan

    1995-01-01

    In the frame work of the project Shuttle Plume Impingement Flight Experiment (SPIFEX), a Load Measurement System was developed and fabricated to measure the impingement force of Shuttle Reaction Control System (RCS) jets. The Load Measurement System is a force sensing system that measures any combination of normal and shear forces up to 40 N (9 lbf) in the normal direction and 22 N (5 lbf) in the shear direction with an accuracy of +/- 0.04 N (+/- 0.01 lbf) Since high resolution is required for the force measurement, the Load Measurement System is built with highly sensitive load cells. To protect these fragile load cells in the non-operational mode from being damaged due to flight loads such as launch and landing loads of the Shuttle vehicle, a motor driven device known as the Load Cell Lock-Out Mechanism was built. This Lock-Out Mechanism isolates the load cells from flight loads and re-engages the load cells for the force measurement experiment once in space. With this highly effective protection system, the SPIFEX load measurement experiment was successfully conducted on STS-44 in September 1994 with all load cells operating properly and reading impingement forces as expected.

  17. Switching power pulse system

    DOEpatents

    Aaland, Kristian

    1983-01-01

    A switching system for delivering pulses of power from a source (10) to a load (20) using a storage capacitor (C3) charged through a rectifier (D1, D2), and maintained charged to a reference voltage level by a transistor switch (Q1) and voltage comparator (12). A thyristor (22) is triggered to discharge the storage capacitor through a saturable reactor (18) and fractional turn saturable transformer (16) having a secondary to primary turn ratio N of n:l/n=n.sup.2. The saturable reactor (18) functions as a "soaker" while the thyristor reaches saturation, and then switches to a low impedance state. The saturable transformer functions as a switching transformer with high impedance while a load coupling capacitor (C4) charges, and then switches to a low impedance state to dump the charge of the storage capacitor (C3) into the load through the coupling capacitor (C4). The transformer is comprised of a multilayer core (26) having two secondary windings (28, 30) tightly wound and connected in parallel to add their output voltage and reduce output inductance, and a number of single turn windings connected in parallel at nodes (32, 34) for the primary winding, each single turn winding linking a different one of the layers of the multilayer core. The load may be comprised of a resistive beampipe (40) for a linear particle accelerator and capacitance of a pulse forming network (42). To hold off discharge of the capacitance until it is fully charged, a saturable core (44) is provided around the resistive beampipe (40) to isolate the beampipe from the capacitance (42) until it is fully charged.

  18. Power system restoration issues

    SciTech Connect

    Adibi, M.M. ); Kafka, R.J. )

    1991-04-01

    This article describes some of the problems encountered in the three phases of power system restoration (PSR). The three phases of PSR are: Planning for restart and reintegration of the bulk power supply; Actions during system degradation for saving and retaining critical sources of power; Restoration when the power system has stabilized at some degraded level.

  19. Power amplification in an isolated muscle–tendon unit is load dependent

    PubMed Central

    Sawicki, Gregory S.; Sheppard, Peter; Roberts, Thomas J.

    2015-01-01

    ABSTRACT During rapid movements, tendons can act like springs, temporarily storing work done by muscles and then releasing it to power body movements. For some activities, such as frog jumping, energy is released from tendon much more rapidly than it is stored, thus amplifying muscle power output. The period during which energy is loaded into a tendon by muscle work may be aided by a catch mechanism that restricts motion, but theoretical studies indicate that power can be amplified in a muscle–tendon load system even in the absence of a catch. To explore the limits of power amplification with and without a catch, we studied the bullfrog plantaris muscle–tendon during in vitro contractions. A novel servomotor controller allowed us to measure muscle–tendon unit (MTU) mechanical behavior during contractions against a variety of simulated inertial-gravitational loads, ranging from zero to 1× the peak isometric force of the muscle. Power output of the MTU system was load dependent and power amplification occurred only at intermediate loads, reaching ∼1.3× the peak isotonic power output of the muscle. With a simulated anatomical catch mechanism in place, the highest power amplification occurred at the lowest loads, with a maximum amplification of more than 4× peak isotonic muscle power. At higher loads, the benefits of a catch for MTU performance diminished sharply, suggesting that power amplification >2.5× may come at the expense of net mechanical work delivered to the load. PMID:26449973

  20. Vehicle load-equalization system

    NASA Technical Reports Server (NTRS)

    Creasy, W. K.

    1976-01-01

    System uses cables and associated pulleys to form closed-loop suspension system for terrain compensation. Loop causes reactions at each of three wheels in response to loading at remaining wheel. Simplicity of design should be of interest to designers and manufacturers of construction equipment and off-road vehicles.

  1. Venezuelan energy resources and electric power system

    SciTech Connect

    Altimari, J.

    1994-06-01

    This article discusses the changing energy policy of Venezuela which is intended to make its electric power sector more competitive. The topics of the article include an overview of the power industry (both private and public utilities), energy sources, power system capacity, generation resources, power demand, load management, and energy conservation.

  2. High power s-band vacuum load

    SciTech Connect

    Neubauer, Michael; Dudas, Alan; Krasnykh, Anatoly

    2016-12-29

    Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

  3. Characterizing and analyzing ramping events in wind power, solar power, load, and netload

    DOE PAGES

    Cui, Mingjian; Zhang, Jie; Feng, Cong; ...

    2017-04-07

    Here, one of the biggest concerns associated with integrating a large amount of renewable energy into the power grid is the ability to handle large ramps in the renewable power output. For the sake of system reliability and economics, it is essential for power system operators to better understand the ramping features of renewable, load, and netload. An optimized swinging door algorithm (OpSDA) is used and extended to accurately and efficiently detect ramping events. For wind power ramps detection, a process of merging 'bumps' (that have a different changing direction) into adjacent ramping segments is included to improve the performancemore » of the OpSDA method. For solar ramps detection, ramping events that occur in both clear-sky and measured (or forecasted) solar power are removed to account for the diurnal pattern of solar generation. Ramping features are extracted and extensively compared between load and netload under different renewable penetration levels (9.77%, 15.85%, and 51.38%). Comparison results show that (i) netload ramp events with shorter durations and smaller magnitudes occur more frequently when renewable penetration level increases, and the total number of ramping events also increases; and (ii) different ramping characteristics are observed in load and netload even with a low renewable penetration level.« less

  4. Photovoltaic power systems workshop

    NASA Technical Reports Server (NTRS)

    Killian, H. J.; Given, R. W.

    1978-01-01

    Discussions are presented on apparent deficiencies in NASA planning and technology development relating to a standard power module (25-35 kW) and to future photovoltaic power systems in general. Topics of discussion consider the following: (1) adequate studies on power systems; (2) whether a standard power system module should be developed from a standard spacecraft; (3) identification of proper approaches to cost reduction; (4) energy storage avoidance; (5) attitude control; (6) thermal effects of heat rejection on solar array configuration stability; (7) assembly of large power systems in space; and (8) factoring terrestrial photovoltaic work into space power systems for possible payoff.

  5. 17. Station Power Center 1 and Load Center 1, view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Station Power Center 1 and Load Center 1, view to the northwest. The power center is the cabinet on the right and the load center is the cabinet on the left of the photograph. A door to the generator barrel of Unit 1 is visible in the background. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  6. Power Plant Systems Analysis

    NASA Technical Reports Server (NTRS)

    Williams, J. R.; Yang, Y. Y.

    1973-01-01

    Three basic thermodynamic cycles of advanced nuclear MHD power plant systems are studied. The effect of reactor exit temperature and space radiator temperature on the overall thermal efficiency of a regenerative turbine compressor power plant system is shown. The effect of MHD pressure ratio on plant efficiency is also described, along with the dependence of MHD power output, compressor power requirement, turbine power output, mass flow rate of H2, and overall plant efficiency on the reactor exit temperature for a specific configuration.

  7. Bifurcation Analysis of a DC-DC Bidirectional Power Converter Operating with Constant Power Loads

    NASA Astrophysics Data System (ADS)

    Cristiano, Rony; Pagano, Daniel J.; Benadero, Luis; Ponce, Enrique

    Direct current (DC) microgrids (MGs) are an emergent option to satisfy new demands for power quality and integration of renewable resources in electrical distribution systems. This work addresses the large-signal stability analysis of a DC-DC bidirectional converter (DBC) connected to a storage device in an islanding MG. This converter is responsible for controlling the balance of power (load demand and generation) under constant power loads (CPLs). In order to control the DC bus voltage through a DBC, we propose a robust sliding mode control (SMC) based on a washout filter. Dynamical systems techniques are exploited to assess the quality of this switching control strategy. In this sense, a bifurcation analysis is performed to study the nonlinear stability of a reduced model of this system. The appearance of different bifurcations when load parameters and control gains are changed is studied in detail. In the specific case of Teixeira Singularity (TS) bifurcation, some experimental results are provided, confirming the mathematical predictions. Both a deeper insight in the dynamic behavior of the controlled system and valuable design criteria are obtained.

  8. Reactive Power Compensating System.

    DOEpatents

    Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.

    1985-01-04

    The circuit was designed for the specific application of wind-driven induction generators. It has great potential for application in any situation where a varying reactive power load is present, such as with induction motors or generators, or for transmission network compensation.

  9. Large autonomous spacecraft electrical power system (LASEPS)

    NASA Technical Reports Server (NTRS)

    Dugal-Whitehead, Norma R.; Johnson, Yvette B.

    1992-01-01

    NASA - Marshall Space Flight Center is creating a large high voltage electrical power system testbed called LASEPS. This testbed is being developed to simulate an end-to-end power system from power generation and source to loads. When the system is completed it will have several power configurations, which will include several battery configurations. These configurations are: two 120 V batteries, one or two 150 V batteries, and one 250 to 270 V battery. This breadboard encompasses varying levels of autonomy from remote power converters to conventional software control to expert system control of the power system elements. In this paper, the construction and provisions of this breadboard are discussed.

  10. Large autonomous spacecraft electrical power system (LASEPS)

    NASA Technical Reports Server (NTRS)

    Dugal-Whitehead, Norma R.; Johnson, Yvette B.

    1992-01-01

    NASA - Marshall Space Flight Center is creating a large high voltage electrical power system testbed called LASEPS. This testbed is being developed to simulate an end-to-end power system from power generation and source to loads. When the system is completed it will have several power configurations, which will include several battery configurations. These configurations are: two 120 V batteries, one or two 150 V batteries, and one 250 to 270 V battery. This breadboard encompasses varying levels of autonomy from remote power converters to conventional software control to expert system control of the power system elements. In this paper, the construction and provisions of this breadboard are discussed.

  11. Influence of load by high power on the optical coupler

    NASA Astrophysics Data System (ADS)

    Bednarek, Lukas; Poboril, Radek; Vanderka, Ales; Hajek, Lukas; Nedoma, Jan; Vasinek, Vladimir

    2016-12-01

    Nowadays, aging of the optical components is a very current topic. Therefore, some investigations are focused on this area, so that the aging of the optical components is accelerated by thermal, high power and gamma load. This paper deals by findings of the influence of the load by laser with high optical power on the transmission parameters of the optical coupler. The investigated coupler has one input and eight outputs (1x8). Load by laser with high optical power is realized using a fiber laser with a cascade configuration EDFA amplifiers. The output power of the amplifier is approximately 250 mW. Duration of the load is moving from 104 hours to 139 hours. After each load, input power and output powers of all branches are measured. Following parameters of the optical coupler are calculated using formulas: the insertion losses of the individual branches, split ratio, total losses, homogeneity of the losses and cross-talk between different branches. All measurements are performed at wavelengths 1310 nm and 1550 nm. Individual optical powers are measured 20 times, due to the exclusion of statistical error of the measurement. After measuring, the coupler is connected to the amplifier for next cycle of the load. The paper contains an evaluation of the results of the coupler before and after four cycles of the burden.

  12. DC switching regulated power supply for driving an inductive load

    DOEpatents

    Dyer, G.R.

    1983-11-29

    A dc switching regulated power supply for driving an inductive load is provided. The regulator basic circuit is a bridge arrangement of diodes and transistors. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. A dc power supply is connected to the input of the bridge and the output is connected to the load. A servo controller is provided to control the switching rate of the transistors to maintain a desired current to the load. The regulator may be operated in three stages or modes: (1) for current runup in the load, both first and second transistor switch arrays are turned on and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned off, and load current flywheels through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays off, allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load.

  13. DC switching regulated power supply for driving an inductive load

    DOEpatents

    Dyer, George R.

    1986-01-01

    A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

  14. Cogeneration power systems

    NASA Technical Reports Server (NTRS)

    Davis, H. S.

    1978-01-01

    Cogeneration is defined as the combination of electrical generation and process heat for more efficient use of fuel. Comparisons of energy utilization in conventional electric power plants and cogeneration electric power plants are presented. Characteristics of various cogeneration systems are also presented. Systems are analyzed for use in utility systems and industrial systems. Economic and cost analysis are reviewed.

  15. Space station power system

    NASA Technical Reports Server (NTRS)

    Baraona, Cosmo R.

    1987-01-01

    The major requirements and guidelines that affect the space station configuration and power system are explained. The evolution of the space station power system from the NASA program development-feasibility phase through the current preliminary design phase is described. Several early station concepts are described and linked to the present concept. Trade study selections of photovoltaic system technologies are described in detail. A summary of present solar dynamic and power management and distribution systems is also given.

  16. Fault-tolerant electrical power system

    NASA Astrophysics Data System (ADS)

    Mehdi, Ishaque S.; Weimer, Joseph A.

    1987-10-01

    An electrical system that will meet the requirements of a 1990s two-engine fighter is being developed in the Fault-Tolerant Electrical Power System (FTEPS) program, sponsored by the AFWAL Aero Propulsion Laboratory. FTEPS will demonstrate the generation and distribution of fault-tolerant, reliable, electrical power required for future aircraft. The system incorporates MIL-STD-1750A digital processors and MIL-STD-1553B data buses for control and communications. Electrical power is distributed through electrical load management centers by means of solid-state power controllers for fault protection and individual load control. The system will provide uninterruptible power to flight-critical loads such as the flight control and mission computers with sealed lead-acid batteries. Primary power is provided by four 60 kVA variable speed constant frequency generators. Buildup and testing of the FTEPS demonstrator is expected to be complete by May 1988.

  17. Power Load Margin Concept: Key Components of Adulthood.

    ERIC Educational Resources Information Center

    Weiman, Elaine R.

    In March 1959, Howard McClusky introduced his Power Load Margin (PLM) theory and proposed that it be used for studying the adult years and for developing and building realistic educational programs for adults. His formula, which states that the key components of adulthood are load (the demands made upon the individual by self and society) and…

  18. Power Load Margin Concept: Key Components of Adulthood.

    ERIC Educational Resources Information Center

    Weiman, Elaine R.

    In March 1959, Howard McClusky introduced his Power Load Margin (PLM) theory and proposed that it be used for studying the adult years and for developing and building realistic educational programs for adults. His formula, which states that the key components of adulthood are load (the demands made upon the individual by self and society) and…

  19. Measurements and Modelling of Base Station Power Consumption under Real Traffic Loads

    PubMed Central

    Lorincz, Josip; Garma, Tonko; Petrovic, Goran

    2012-01-01

    Base stations represent the main contributor to the energy consumption of a mobile cellular network. Since traffic load in mobile networks significantly varies during a working or weekend day, it is important to quantify the influence of these variations on the base station power consumption. Therefore, this paper investigates changes in the instantaneous power consumption of GSM (Global System for Mobile Communications) and UMTS (Universal Mobile Telecommunications System) base stations according to their respective traffic load. The real data in terms of the power consumption and traffic load have been obtained from continuous measurements performed on a fully operated base station site. Measurements show the existence of a direct relationship between base station traffic load and power consumption. According to this relationship, we develop a linear power consumption model for base stations of both technologies. This paper also gives an overview of the most important concepts which are being proposed to make cellular networks more energy-efficient. PMID:22666026

  20. Measurements and modelling of base station power consumption under real traffic loads.

    PubMed

    Lorincz, Josip; Garma, Tonko; Petrovic, Goran

    2012-01-01

    Base stations represent the main contributor to the energy consumption of a mobile cellular network. Since traffic load in mobile networks significantly varies during a working or weekend day, it is important to quantify the influence of these variations on the base station power consumption. Therefore, this paper investigates changes in the instantaneous power consumption of GSM (Global System for Mobile Communications) and UMTS (Universal Mobile Telecommunications System) base stations according to their respective traffic load. The real data in terms of the power consumption and traffic load have been obtained from continuous measurements performed on a fully operated base station site. Measurements show the existence of a direct relationship between base station traffic load and power consumption. According to this relationship, we develop a linear power consumption model for base stations of both technologies. This paper also gives an overview of the most important concepts which are being proposed to make cellular networks more energy-efficient.

  1. Maximum power training load determination and its effects on load-power relationship, maximum strength, and vertical jump performance.

    PubMed

    Smilios, Ilias; Sotiropoulos, Konstantinos; Christou, Marios; Douda, Helen; Spaias, Aggelos; Tokmakidis, Savvas P

    2013-05-01

    This study examines the changes in maximum strength, vertical jump performance, and the load-velocity and load-power relationship after a resistance training period using a heavy load and an individual load that maximizes mechanical power output with and without including body mass in power calculations. Forty-three moderately trained men (age: 22.7 ± 2.5 years) were separated into 4 groups, 2 groups of maximum power, 1 where body mass was not included in the calculations of the load that maximizes mechanical power (Pmax - bw, n = 11) and another where body mass was included in the calculations (Pmax + bw, n = 9), a high load group (HL-90%, n = 12), and a control group (C, n = 11). The subjects performed 4-6 sets of jump squat and the repeated-jump exercises for 6 weeks. For the jump squat, the HL-90% group performed 3 repetitions at each set with a load of 90% of 1 repetition maximum (1RM), the Pmax - bw group 5 repetitions with loads 48-58% of 1RM and the Pmax + bw 8 repetitions with loads 20-37% of 1RM. For the repeated jump, all the groups performed 6 repetitions at each set. All training groups improved (p < 0.05) maximum strength in the semisquat exercise (HL-90%: 15.2 ± 7.1, Pmax - bw: 6.6 ± 4.7, Pmax + bw: 6.9 ± 7.1, and C: 0 ± 4.3%) and the HL-90% group presented higher values (p < 0.05) than the other groups did. All training groups improved similarly (p < 0.05) squat (HL-90%: 11.7 ± 7.9, Pmax - bw: 14.5 ± 11.8, Pmax + bw: 11.3 ± 7.9, and C: -2.2 ± 5.5%) and countermovement jump height (HL-90%: 8.6 ± 7.9, Pmax - bw: 10.9 ± 9.4, Pmax + bw: 8.8 ± 4.3, and C: 0.4 ± 6%). The HL-90% and the Pmax - bw group increased (p < 0.05) power output at loads of 20, 35, 50, 65, and 80% of 1RM and the Pmax + bw group at loads of 20 and 35% of 1RM. The inclusion or not of body mass to determine the load that maximizes mechanical power output affects the long-term adaptations differently in the load-power relationship. Thus, training load selection will depend

  2. Automated fuel pin loading system

    DOEpatents

    Christiansen, D.W.; Brown, W.F.; Steffen, J.M.

    An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inerted as a batch prior to welding of end caps by one of two disclosed welding systems.

  3. Automated fuel pin loading system

    DOEpatents

    Christiansen, David W.; Brown, William F.; Steffen, Jim M.

    1985-01-01

    An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

  4. Comparison of Deterministic and Probabilistic Radial Distribution Systems Load Flow

    NASA Astrophysics Data System (ADS)

    Gupta, Atma Ram; Kumar, Ashwani

    2017-08-01

    Distribution system network today is facing the challenge of meeting increased load demands from the industrial, commercial and residential sectors. The pattern of load is highly dependent on consumer behavior and temporal factors such as season of the year, day of the week or time of the day. For deterministic radial distribution load flow studies load is taken as constant. But, load varies continually with a high degree of uncertainty. So, there is a need to model probable realistic load. Monte-Carlo Simulation is used to model the probable realistic load by generating random values of active and reactive power load from the mean and standard deviation of the load and for solving a Deterministic Radial Load Flow with these values. The probabilistic solution is reconstructed from deterministic data obtained for each simulation. The main contribution of the work is: Finding impact of probable realistic ZIP load modeling on balanced radial distribution load flow. Finding impact of probable realistic ZIP load modeling on unbalanced radial distribution load flow. Compare the voltage profile and losses with probable realistic ZIP load modeling for balanced and unbalanced radial distribution load flow.

  5. Monitoring Wind Turbine Loading Using Power Converter Signals

    NASA Astrophysics Data System (ADS)

    Rieg, C. A.; Smith, C. J.; Crabtree, C. J.

    2016-09-01

    The ability to detect faults and predict loads on a wind turbine drivetrain's mechanical components cost-effectively is critical to making the cost of wind energy competitive. In order to investigate whether this is possible using the readily available power converter current signals, an existing permanent magnet synchronous generator based wind energy conversion system computer model was modified to include a grid-side converter (GSC) for an improved converter model and a gearbox. The GSC maintains a constant DC link voltage via vector control. The gearbox was modelled as a 3-mass model to allow faults to be included. Gusts and gearbox faults were introduced to investigate the ability of the machine side converter (MSC) current (I q) to detect and quantify loads on the mechanical components. In this model, gearbox faults were not detectable in the I q signal due to shaft stiffness and damping interaction. However, a model that predicts the load change on mechanical wind turbine components using I q was developed and verified using synthetic and real wind data.

  6. Economical space power systems

    NASA Technical Reports Server (NTRS)

    Burkholder, J. H.

    1980-01-01

    A commercial approach to design and fabrication of an economical space power system is investigated. Cost projections are based on a 2 kW space power system conceptual design taking into consideration the capability for serviceability, constraints of operation in space, and commercial production engineering approaches. A breakdown of the system design, documentation, fabrication, and reliability and quality assurance estimated costs are detailed.

  7. International Space Station Power Systems

    NASA Technical Reports Server (NTRS)

    Propp, Timothy William

    2001-01-01

    This viewgraph presentation gives a general overview of the International Space Station Power Systems. The topics include: 1) The Basics of Power; 2) Space Power Systems Design Constraints; 3) Solar Photovoltaic Power Systems; 4) Energy Storage for Space Power Systems; 5) Challenges of Operating Power Systems in Earth Orbit; 6) and International Space Station Electrical Power System.

  8. Power system commonality study

    NASA Astrophysics Data System (ADS)

    Littman, Franklin D.

    1992-07-01

    A limited top level study was completed to determine the commonality of power system/subsystem concepts within potential lunar and Mars surface power system architectures. A list of power system concepts with high commonality was developed which can be used to synthesize power system architectures which minimize development cost. Examples of potential high commonality power system architectures are given in this report along with a mass comparison. Other criteria such as life cycle cost (which includes transportation cost), reliability, safety, risk, and operability should be used in future, more detailed studies to select optimum power system architectures. Nineteen potential power system concepts were identified and evaluated for planetary surface applications including photovoltaic arrays with energy storage, isotope, and nuclear power systems. A top level environmental factors study was completed to assess environmental impacts on the identified power system concepts for both lunar and Mars applications. Potential power system design solutions for commonality between Mars and lunar applications were identified. Isotope, photovoltaic array (PVA), regenerative fuel cell (RFC), stainless steel liquid-metal cooled reactors (less than 1033 K maximum) with dynamic converters, and in-core thermionic reactor systems were found suitable for both lunar and Mars environments. The use of SP-100 thermoelectric (TE) and SP-100 dynamic power systems in a vacuum enclosure may also be possible for Mars applications although several issues need to be investigated further (potential single point failure of enclosure, mass penalty of enclosure and active pumping system, additional installation time and complexity). There are also technical issues involved with development of thermionic reactors (life, serviceability, and adaptability to other power conversion units). Additional studies are required to determine the optimum reactor concept for Mars applications. Various screening

  9. Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies

    DTIC Science & Technology

    2012-09-01

    electric ships, being aware of the stability issues associated with direct current (DC)-DC and DC-alternating current (AC) power converters and...problem here is that in MVDC shipboard power systems, the DC-DC converters are used to supply constant power to electrical loads, and these loads have...OF A CONSTANT POWER LOAD SERVICED BY A BUCK CONVERTER AS THE SOURCE IMPEDANCE VARIES by George J. Roth September 2012 Thesis Advisor

  10. Power modules and projected power systems evolution

    NASA Technical Reports Server (NTRS)

    Brantley, L. W.

    1978-01-01

    Photovoltaic, solar thermal, and nuclear power systems are considered to supply future earth orbital electrical power requirements. A growth scenario from a 25-kW Power Module in the early Shuttle era to the 5- to 10-GW Satellite Power System in the year 2000 is presented. Photovoltaic systems are presently baselined in this evolution. The Photovoltaic Power System and subsystem growth projections, consistent with this scenario, were developed and are summarized.

  11. Space Nuclear Power Systems

    NASA Technical Reports Server (NTRS)

    Houts, Michael G.

    2012-01-01

    Fission power and propulsion systems can enable exciting space exploration missions. These include bases on the moon and Mars; and the exploration, development, and utilization of the solar system. In the near-term, fission surface power systems could provide abundant, constant, cost-effective power anywhere on the surface of the Moon or Mars, independent of available sunlight. Affordable access to Mars, the asteroid belt, or other destinations could be provided by nuclear thermal rockets. In the further term, high performance fission power supplies could enable both extremely high power levels on planetary surfaces and fission electric propulsion vehicles for rapid, efficient cargo and crew transfer. Advanced fission propulsion systems could eventually allow routine access to the entire solar system. Fission systems could also enable the utilization of resources within the solar system.

  12. Electrical power generating system

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1983-01-01

    A power generating system for adjusting coupling an induction motor, as a generator, to an A.C. power line wherein the motor and power line are connected through a triac is described. The triac is regulated to normally turn on at a relatively late point in each half cycle of its operation, whereby at less than operating speed, and thus when the induction motor functions as a motor rather than as a generator, power consumption from the line is substantially reduced.

  13. TPX power systems design overview

    SciTech Connect

    Neumeyer, C.; Bronner, G.; Lu, E.; Ramakrishnan, S.; Jackson, M.

    1993-11-01

    The power systems for the Tokamak Physics Experiment (TPX) supply the Toroidal Field (TF). Poloidal Field (PF), Field Error Correction (FEC), and Fast Vertical Position Control (FVPC) coil systems, the Neutral Beam (NB), Ion Cyclotron (IC), Lower Hybrid (LH) and Electron Cyclotron (EC) heating and current drive systems, and all balance of plant loads. Existing equipment from the Tokamak Fusion Test Reactor (TFTR), including the motor-generator (MG) sets and the rectifiers, can be adapted for the supply of the TPX PF systems. A new TF power supply is required. A new substation is required for the heating and current drive systems (NB, IC, LH, and EC). The baseline TPX load can be taken directly from the grid without special provision, whereas if all upgrade options are undertaken, a modest amount of reactive compensation will be required. This paper describes the conceptual design of the power systems, with emphasis on the AC, TF, and PF Systems, and the quench protection of the superconducting coils.

  14. Simplified Load-Following Control for a Fuel Cell System

    NASA Technical Reports Server (NTRS)

    Vasquez, Arturo

    2010-01-01

    A simplified load-following control scheme has been proposed for a fuel cell power system. The scheme could be used to control devices that are important parts of a fuel cell system but are sometimes characterized as parasitic because they consume some of the power generated by the fuel cells.

  15. Load controller and method to enhance effective capacity of a photovoltaic power supply using a dynamically determined expected peak loading

    DOEpatents

    Perez, Richard

    2005-05-03

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply.

  16. Automated Loads Analysis System (ATLAS)

    NASA Technical Reports Server (NTRS)

    Gardner, Stephen; Frere, Scot; O’Reilly, Patrick

    2013-01-01

    ATLAS is a generalized solution that can be used for launch vehicles. ATLAS is used to produce modal transient analysis and quasi-static analysis results (i.e., accelerations, displacements, and forces) for the payload math models on a specific Shuttle Transport System (STS) flight using the shuttle math model and associated forcing functions. This innovation solves the problem of coupling of payload math models into a shuttle math model. It performs a transient loads analysis simulating liftoff, landing, and all flight events between liftoff and landing. ATLAS utilizes efficient and numerically stable algorithms available in MSC/NASTRAN.

  17. Power Systems integration

    NASA Technical Reports Server (NTRS)

    Brantley, L. W.

    1982-01-01

    Power systems integration in large flexible space structures is discussed with emphasis upon body control. A solar array is discussed as a typical example of spacecraft configuration problems. Information on how electric batteries dominate life-cycle costs is presented in chart form. Information is given on liquid metal droplet generators and collectors, hot spot analysis, power dissipation in solar arrays, solar array protection optimization, and electromagnetic compatibility for a power system platform.

  18. Contrast loading: power output and rest interval effects on neuromuscular performance.

    PubMed

    Sotiropoulos, Konstantinos; Smilios, Ilias; Douda, Helen; Chritou, Marios; Tokmakidis, Savvas P

    2014-05-01

    This study examined the effect of rest interval after the execution of a jump-squat set with varied external mechanical-power outputs on repeated-jump (RJ) height, mechanical power, and electromyographic (EMG) activity. Twelve male volleyball players executed 6 RJs before and 1, 3, 5, 7, and 10 min after the execution of 6 repetitions of jump squats with a load: maximized mechanical-power output (Pmax), 70% of Pmax, 130% of Pmax, and control, without extra load. RJ height did not change (P = .44) after the jump squats, mechanical power was higher (P = .02) 5 min after the 130%Pmax protocol, and EMG activity was higher (P = .001) after all exercise protocols compared with control. Irrespective of the time point, however, when the highest RJ set for each individual was analyzed, height, mechanical power, and EMG activity were higher (P = .001-.04) after all loading protocols compared with control, with no differences observed (P = .53-.72) among loads. Rest duration for a contrast-training session should be individually determined regardless of the load and mechanical-power output used to activate the neuromuscular system. The load that maximizes external mechanical-power output compared with a heavier or a lighter load, using the jump-squat exercise, is not more effective for increasing jumping performance afterward.

  19. Power amplification in an isolated muscle-tendon unit is load dependent.

    PubMed

    Sawicki, Gregory S; Sheppard, Peter; Roberts, Thomas J

    2015-11-01

    During rapid movements, tendons can act like springs, temporarily storing work done by muscles and then releasing it to power body movements. For some activities, such as frog jumping, energy is released from tendon much more rapidly than it is stored, thus amplifying muscle power output. The period during which energy is loaded into a tendon by muscle work may be aided by a catch mechanism that restricts motion, but theoretical studies indicate that power can be amplified in a muscle-tendon load system even in the absence of a catch. To explore the limits of power amplification with and without a catch, we studied the bullfrog plantaris muscle-tendon during in vitro contractions. A novel servomotor controller allowed us to measure muscle-tendon unit (MTU) mechanical behavior during contractions against a variety of simulated inertial-gravitational loads, ranging from zero to 1× the peak isometric force of the muscle. Power output of the MTU system was load dependent and power amplification occurred only at intermediate loads, reaching ∼1.3× the peak isotonic power output of the muscle. With a simulated anatomical catch mechanism in place, the highest power amplification occurred at the lowest loads, with a maximum amplification of more than 4× peak isotonic muscle power. At higher loads, the benefits of a catch for MTU performance diminished sharply, suggesting that power amplification >2.5× may come at the expense of net mechanical work delivered to the load. © 2015. Published by The Company of Biologists Ltd.

  20. Wireless power charging using point of load controlled high frequency power converters

    DOEpatents

    Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.

    2015-10-13

    An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

  1. Load optimised piezoelectric generator for powering battery-less TPMS

    NASA Astrophysics Data System (ADS)

    Blažević, D.; Kamenar, E.; Zelenika, S.

    2013-05-01

    The design of a piezoelectric device aimed at harvesting the kinetic energy of random vibrations on a vehicle's wheel is presented. The harvester is optimised for powering a Tire Pressure Monitoring System (TPMS). On-road experiments are performed in order to measure the frequencies and amplitudes of wheels' vibrations. It is hence determined that the highest amplitudes occur in an unperiodic manner. Initial tests of the battery-less TPMS are performed in laboratory conditions where tuning and system set-up optimization is achieved. The energy obtained from the piezoelectric bimorph is managed by employing the control electronics which converts AC voltage to DC and conditions the output voltage to make it compatible with the load (i.e. sensor electronics and transmitter). The control electronics also manages the sleep/measure/transmit cycles so that the harvested energy is efficiently used. The system is finally tested in real on-road conditions successfully powering the pressure sensor and transmitting the data to a receiver in the car cockpit.

  2. TROPIX Power System Architecture

    NASA Technical Reports Server (NTRS)

    Manner, David B.; Hickman, J. Mark

    1995-01-01

    This document contains results obtained in the process of performing a power system definition study of the TROPIX power management and distribution system (PMAD). Requirements derived from the PMADs interaction with other spacecraft systems are discussed first. Since the design is dependent on the performance of the photovoltaics, there is a comprehensive discussion of the appropriate models for cells and arrays. A trade study of the array operating voltage and its effect on array bus mass is also presented. A system architecture is developed which makes use of a combination of high efficiency switching power convertors and analog regulators. Mass and volume estimates are presented for all subsystems.

  3. TROPIX power system architecture

    NASA Astrophysics Data System (ADS)

    Manner, David B.; Hickman, J. Mark

    1995-09-01

    This document contains results obtained in the process of performing a power system definition study of the TROPIX power management and distribution system (PMAD). Requirements derived from the PMADs interaction with other spacecraft systems are discussed first. Since the design is dependent on the performance of the photovoltaics, there is a comprehensive discussion of the appropriate models for cells and arrays. A trade study of the array operating voltage and its effect on array bus mass is also presented. A system architecture is developed which makes use of a combination of high efficiency switching power convertors and analog regulators. Mass and volume estimates are presented for all subsystems.

  4. Optimal shifting of Photovoltaic and load fluctuations from fuel cell and electrolyzer to lead acid battery in a Photovoltaic/hydrogen standalone power system for improved performance and life time

    NASA Astrophysics Data System (ADS)

    Tesfahunegn, S. G.; Ulleberg, Ø.; Vie, P. J. S.; Undeland, T. M.

    Cost reduction is very critical in the pursuit of realizing more competitive clean and sustainable energy systems. In line with this goal a control method that enables minimization of the cost associated with performance and life time degradation of fuel cell and electrolyzer, and cost of battery replacement in PV/hydrogen standalone power systems is developed. The method uses the advantage of existing peak shaving battery to suppress short-term PV and load fluctuations while reducing impact on the cycle life of the battery itself. This is realized by diverting short-term cyclic charge/discharge events induced by PV/load power fluctuations to the upper band of the battery state of charge regime while operating the fuel cell and electrolyzer systems along stable (smooth) power curves. Comparative studies of the developed method with two other reference cases demonstrate that the proposed method fares better with respect to defined performance indices as fluctuation suppression rate and mean state of charge. Modeling of power electronics and design of controllers used in the study are also briefly discussed in Appendix A.

  5. A Tool for Model-Based Generation of Scenario-driven Electric Power Load Profiles

    NASA Technical Reports Server (NTRS)

    Rozek, Matthew L.; Donahue, Kenneth M.; Ingham, Michel D.; Kaderka, Justin D.

    2015-01-01

    Power consumption during all phases of spacecraft flight is of great interest to the aerospace community. As a result, significant analysis effort is exerted to understand the rates of electrical energy generation and consumption under many operational scenarios of the system. Previously, no standard tool existed for creating and maintaining a power equipment list (PEL) of spacecraft components that consume power, and no standard tool existed for generating power load profiles based on this PEL information during mission design phases. This paper presents the Scenario Power Load Analysis Tool (SPLAT) as a model-based systems engineering tool aiming to solve those problems. SPLAT is a plugin for MagicDraw (No Magic, Inc.) that aids in creating and maintaining a PEL, and also generates a power and temporal variable constraint set, in Maple language syntax, based on specified operational scenarios. The constraint set can be solved in Maple to show electric load profiles (i.e. power consumption from loads over time). SPLAT creates these load profiles from three modeled inputs: 1) a list of system components and their respective power modes, 2) a decomposition hierarchy of the system into these components, and 3) the specification of at least one scenario, which consists of temporal constraints on component power modes. In order to demonstrate how this information is represented in a system model, a notional example of a spacecraft planetary flyby is introduced. This example is also used to explain the overall functionality of SPLAT, and how this is used to generate electric power load profiles. Lastly, a cursory review of the usage of SPLAT on the Cold Atom Laboratory project is presented to show how the tool was used in an actual space hardware design application.

  6. Novel Musculoskeletal Loading and Assessment System

    NASA Technical Reports Server (NTRS)

    Downs, Meghan E.

    2017-01-01

    Ground based and ISS (International Space Station) exercise research have shown that axial loading via two-point loading at the shoulders and load quality (i.e. consistent load and at least 1:1 concentric to eccentric ratio) are extremely important to optimize musculoskeletal adaptations to resistance exercise. The Advanced Resistance Exercise Device (ARED) is on ISS now and is the "state of the art" for resistance exercise capabilities in microgravity; however, the ARED is far too large and power consuming for exploration vehicles. The single cable exercise device design selected for MPCV (Multi-Purpose Crew Vehicle), does not readily allow for the two-point loading at the shoulders.

  7. Modeling of DC spacecraft power systems

    NASA Technical Reports Server (NTRS)

    Berry, F. C.

    1995-01-01

    Future spacecraft power systems must be capable of supplying power to various loads. This delivery of power may necessitate the use of high-voltage, high-power dc distribution systems to transmit power from the source to the loads. Using state-of-the-art power conditioning electronics such as dc-dc converters, complex series and parallel configurations may be required at the interface between the source and the distribution system and between the loads and the distribution system. This research will use state-variables to model and simulate a dc spacecraft power system. Each component of the dc power system will be treated as a multiport network, and a state model will be written with the port voltages as the inputs. The state model of a component will be solved independently from the other components using its state transition matrix. A state-space averaging method is developed first in general for any dc-dc switching converter, and then demonstrated in detail for the particular case of the boost power stage. General equations for both steady-state (dc) and dynamic effects (ac) are obtained, from which important transfer functions are derived and applied to a special case of the boost power stage.

  8. Power system characteristics for more electric aircraft

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.

    1993-01-01

    It should not be suprising that more electric aircraft must meet significantly more difficult electrical power system requirements than were considereed when today's power distribution systems were being developed. Electric power, no longer a secondary system, will become a critical element of the primary control system. Functional reliability requiirements will be extremely stringent and can only be met by controlling element redundancy within a distributed power system. Existing electrical systems were not developed to have both the power system and the control/sensing elements distributed and yet meet the requirements of lighting tolerance and high intensity radio frequency (HIRF). In addition, the operation of electric actuators involves high transient loading and reverse energy flows. Such phenomena were also not anticipated when power quality was specified for either 270 vdc or 400 Hertz ac power systems. This paper will expand upon the issues and discuss some of the technologies involved in their resolution.

  9. Study of Flexible Load Dispatch to Improve the Capacity of Wind Power Absorption

    NASA Astrophysics Data System (ADS)

    Yunlei, Yang; Shifeng, Zhang; Xiao, Chang; Da, Lei; Min, Zhang; Jinhao, Wang; Shengwen, Li; Huipeng, Li

    2017-05-01

    The dispatch method which track the trend of load demand by arranging the generation scheme of controllable hydro or thermal units faces great difficulties and challenges. With the increase of renewable energy sources such as wind power and photovoltaic power introduced to grid, system has to arrange much more spinning reserve units to compensate the unbalanced power. How to exploit the peak-shaving potential of flexible load which can be shifted with time or storage energy has become many scholars’ research direction. However, the modelling of different kinds of load and control strategy is considerably difficult, this paper choose the Air Conditioner with compressor which can storage energy in fact to study. The equivalent thermal parameters of Air Conditioner has been established. And with the use of “loop control” strategies, we can predict the regulated power of Air Conditioner. Then we established the Gen-Load optimal scheduling model including flexible load based on traditional optimal scheduling model. At last, an improved IEEE-30 case is used to verify. The result of simulation shows that flexible load can fast-track renewable power changes. More than that, with flexible load and reasonable incentive method to consumers, the operating cost of the system can be greatly cut down.

  10. The Ames Power Monitoring System

    NASA Technical Reports Server (NTRS)

    Osetinsky, Leonid; Wang, David

    2003-01-01

    The Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also

  11. Demand Response For Power System Reliability: FAQ

    SciTech Connect

    Kirby, Brendan J

    2006-12-01

    Demand response is the most underutilized power system reliability resource in North America. Technological advances now make it possible to tap this resource to both reduce costs and improve. Misconceptions concerning response capabilities tend to force loads to provide responses that they are less able to provide and often prohibit them from providing the most valuable reliability services. Fortunately this is beginning to change with some ISOs making more extensive use of load response. This report is structured as a series of short questions and answers that address load response capabilities and power system reliability needs. Its objective is to further the use of responsive load as a bulk power system reliability resource in providing the fastest and most valuable ancillary services.

  12. Overload protection system for power inverter

    NASA Technical Reports Server (NTRS)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  13. Knowledge-based systems for power management

    NASA Technical Reports Server (NTRS)

    Lollar, L. F.

    1992-01-01

    NASA-Marshall's Electrical Power Branch has undertaken the development of expert systems in support of further advancements in electrical power system automation. Attention is given to the features (1) of the Fault Recovery and Management Expert System, (2) a resource scheduler or Master of Automated Expert Scheduling Through Resource Orchestration, and (3) an adaptive load-priority manager, or Load Priority List Management System. The characteristics of an advisory battery manager for the Hubble Space Telescope, designated the 'nickel-hydrogen expert system', are also noted.

  14. Study on load forecasting to data centers of high power density based on power usage effectiveness

    NASA Astrophysics Data System (ADS)

    Zhou, C. C.; Zhang, F.; Yuan, Z.; Zhou, L. M.; Wang, F. M.; Li, W.; Yang, J. H.

    2016-08-01

    There is usually considerable energy consumption in data centers. Load forecasting to data centers is in favor of formulating regional load density indexes and of great benefit to getting regional spatial load forecasting more accurately. The building structure and the other influential factors, i.e. equipment, geographic and climatic conditions, are considered for the data centers, and a method to forecast the load of the data centers based on power usage effectiveness is proposed. The cooling capacity of a data center and the index of the power usage effectiveness are used to forecast the power load of the data center in the method. The cooling capacity is obtained by calculating the heat load of the data center. The index is estimated using the group decision-making method of mixed language information. An example is given to prove the applicability and accuracy of this method.

  15. Modular, high power, variable R dynamic electrical load simulator

    NASA Technical Reports Server (NTRS)

    Joncas, K. P.

    1974-01-01

    The design of a previously developed basic variable R load simulator was entended to increase its power dissipation and transient handling capabilities. The delivered units satisfy all design requirements, and provides for a high power, modular simulation capability uniquely suited to the simulation of complex load responses. In addition to presenting conclusions and recommendations and pertinent background information, the report covers program accomplishments; describes the simulator basic circuits, transfer characteristic, protective features, assembly, and specifications; indicates the results of simulator evaluation, including burn-in and acceptance testing; provides acceptance test data; and summarizes the monthly progress reports.

  16. SITE ELECTRICAL POWER SYSTEM DESCRIPTION DOCUMENT

    SciTech Connect

    E.P. McCann

    1999-04-16

    The Site Electrical Power System receives and distributes utility power to all North Portal site users. The major North Portal users are the Protected Area including the subsurface facility and Balance of Plant areas. The system is remotely monitored and controlled from the Surface Operations Monitoring and Control System. The system monitors power quality and provides the capability to transfer between Off-Site Utility and standby power (including dedicated safeguards and security power). Standby power is only distributed to selected loads for personnel safety and essential operations. Security power is only distributed to essential security operations. The standby safeguards and security power is independent from all other site power. The system also provides surface lighting, grounding grid, and lightning protection for the North Portal. The system distributes power during construction, operation, caretaker, and closure phases of the repository. The system consists of substation equipment (disconnect switches, breakers, transformers and grounding equipment) and power distribution cabling from substation to the north portal switch gear building. Additionally, the system includes subsurface facility substation (located on surface), switch-gear, standby diesel generators, underground duct banks, power cables and conduits, switch-gear building and associated distribution equipment for power distribution. Each area substation distributes power to the electrical loads and includes the site grounding, site lighting and lightning protection equipment. The site electrical power system distributes power of sufficient quantity and quality to meet users demands. The Site Electrical Power System interfaces with the North Portal surface systems requiring electrical power. The system interfaces with the Subsurface Electrical Distribution System which will supply power to the underground facilities from the North Portal. Power required for the South Portal and development side

  17. Power Systems Control Architecture

    SciTech Connect

    James Davidson

    2005-01-01

    A diagram provided in the report depicts the complexity of the power systems control architecture used by the national power structure. It shows the structural hierarchy and the relationship of the each system to those other systems interconnected to it. Each of these levels provides a different focus for vulnerability testing and has its own weaknesses. In evaluating each level, of prime concern is what vulnerabilities exist that provide a path into the system, either to cause the system to malfunction or to take control of a field device. An additional vulnerability to consider is can the system be compromised in such a manner that the attacker can obtain critical information about the system and the portion of the national power structure that it controls.

  18. Satellite power system operations

    NASA Technical Reports Server (NTRS)

    Pugh, F. L.; Gordon, A. I.

    1980-01-01

    A projection of the electrical energy demands over the next 30 to 50 years, coupled with reasonable assessments of known or developable energy sources, indicates that a shortage of electrical energy will occur about the turn of the century. Recognizing the criticality of such a shortage, the Department of Energy is currently evaluating alternative power generation concepts. One of these candidate concepts is the Satellite Power System. The power levels considered during the evaluation of the various satellite systems have ranged from 5 to 10 GW. It is apparent that, with this power level, both the satellite and the rectenna must be very large and encompass a large number of complex operational system activities. Major elements of the Satellite Power System (SPS) consist of a power satellite placed in a geosynchronous equatorial orbit, and a dedicated ground receiving station (GRS) located at a selected site within the continental United States. The nominal power output of the SPS is established at 5 gigawatts (5 million kilowatts) although, because of various system constraints or losses, it may actually produce between 4 and 5 gigawatts.

  19. An analysis of space power system masses

    NASA Technical Reports Server (NTRS)

    Kenny, Barbara H.; Cull, Ronald C.; Kankam, M. D.

    1990-01-01

    Various space electrical power system masses are analyzed with particular emphasis on the power management and distribution (PMAD) portion. The electrical power system (EPS) is divided into functional blocks: source, interconnection, storage, transmission, distribution, system control and load. The PMAD subsystem is defined as all the blocks between the source, storage and load, plus the power conditioning equipment required for the source, storage and load. The EPS mass of a wide range of spacecraft is then classified as source, storage or PMAD and tabulated in a database. The intent of the database is to serve as a reference source for PMAD masses of existing and in-design spacecraft. The PMAD masses in the database range from 40 kg/kW to 183 kg/kW across the spacecraft systems studied. Factors influencing the power system mass are identified. These include the total spacecraft power requirements, total amount of load capacity and physical size of the spacecraft. It is found that a new utility class of power systems, represented by Space Station Freedom, is evolving.

  20. An analysis of space power system masses

    SciTech Connect

    Kenny, B.H.; Cull, R.C.; Kankam, M.D.

    1990-01-01

    Various space electrical power system masses are analyzed with particular emphasis on the power management and distribution (PMAD) portion. The electrical power system (EPS) is divided into functional blocks: source, interconnection, storage, transmission, distribution, system control and load. The PMAD subsystem is defined as all the blocks between the source, storage and load, plus the power conditioning equipment required for the source, storage and load. The EPS mass of a wide range of spacecraft is then classified as source, storage or PMAD and tabulated in a database. The intent of the database is to serve as a reference source for PMAD masses of existing and in-design spacecraft. The PMAD masses in the database range from 40 kg/kW to 183 kg/kW across the spacecraft systems studied. Factors influencing the power system mass are identified. These include the total spacecraft power requirements, total amount of load capacity and physical size of the spacecraft. It is found that a new utility class of power systems, represented by Space Station Freedom, is evolving.

  1. Load-Following Power Timeline Analyses for the International Space Station

    NASA Technical Reports Server (NTRS)

    Fincannon, James; Delleur, Ann; Green, Robert; Hojnicki, Jeffrey

    1996-01-01

    Spacecraft are typically complex assemblies of interconnected systems and components that have highly time-varying thermal communications, and power requirements. It is essential that systems designers be able to assess the capability of the spacecraft to meet these requirements which should represent a realistic projection of demand for these resources once the vehicle is on-orbit. To accomplish the assessment from the power standpoint, a computer code called ECAPS has been developed at NASA Lewis Research Center that performs a load-driven analysis of a spacecraft power system given time-varying distributed loading and other mission data. This program is uniquely capable of synthesizing all of the changing spacecraft conditions into a single, seamless analysis for a complete mission. This paper presents example power load timelines with which numerous data are integrated to provide a realistic assessment of the load-following capabilities of the power system. Results of analyses show how well the power system can meet the time-varying power resource demand.

  2. Cruise Missile Power System

    DTIC Science & Technology

    1986-03-01

    fluxuations decrease to 0 at yoke and shaft. The argument is made by averaging the air gap around the rotor as the rotor turns. The air gap is nearly...other altitudes and maximum load conditions . Figure 28 shows the effect of using the 110 OF inlet air temperature on system efficiency. Mass flow rates...verify the validity of the system cooling method. o Instrumentation - Airflow. The condition of the air , both upstream and downstream of the generator

  3. AC power system breadboard

    NASA Technical Reports Server (NTRS)

    Wappes, Loran J.; Sundberg, R.; Mildice, J.; Peterson, D.; Hushing, S.

    1987-01-01

    The object of this program was to design, build, test, and deliver a high-frequency (20-kHz) Power System Breadboard which would electrically approximate a pair of dual redundant power channels of an IOC Space Station. This report describes that program, including the technical background, and discusses the results, showing that the major assumptions about the characteristics of this class of hardware (size, mass, efficiency, control, etc.) were substantially correct. This testbed equipment has been completed and delivered to LeRC, where it is operating as a part of the Space Station Power System Test Facility.

  4. Power system applications for PASC converter systems

    SciTech Connect

    Donnelly, M.K.; Johnson, R.M.

    1994-04-01

    This paper shows, using computer EMTP simulations, some preliminary results of applying pulse amplitude synthesis and control (PASC) technology to single-source level voltage converter system. The method can be applied to any single terminal pair source with appropriate modifications in power extraction interface and computer control program to match source and load impedance characteristics. The PASC realization as discussed here employs banks of transformers, one bank per phase, in which the primaries are connected in parallel through a switch matrix to the dc source. Two opposite polarity primaries per transformer are pulsed alternatively in time to produce an oscillatory sinusoidal output waveform. PASC conversion system capabilities to produce both leading and lagging power factor power output in single-phase and three-phase {Delta} or Y configurations are illustrated. EMTP simulations are used to demonstrate the converter capabilities. Also included are discussions regarding harmonics and potential control strategies to adapt the converter to an application or to minimize harmonics.

  5. Power system applications for PASC converter systems

    NASA Astrophysics Data System (ADS)

    Donnelly, M. K.; Johnson, R. M.

    1994-04-01

    This paper shows, using computer EMTP simulations, some preliminary results of applying pulse amplitude synthesis and control (PASC) technology to single-source level voltage converter system. The method can be applied to any single terminal pair source with appropriate modifications in power extraction interface and computer control program to match source and load impedance characteristics. The PASC realization as discussed here employs banks of transformers, one bank per phase, in which the primaries are connected in parallel through a switch matrix to the dc source. Two opposite polarity primaries per transformer are pulsed alternatively in time to produce an oscillatory sinusoidal output waveform. PASC conversion system capabilities to produce both leading and lagging power factor power output in single-phase and three-phase (Delta) or Y configurations are illustrated. EMTP simulations are used to demonstrate the converter capabilities. Also included are discussions regarding harmonics and potential control strategies to adapt the converter to an application or to minimize harmonics.

  6. Power system applications for PASC converter systems

    SciTech Connect

    Donnelly, M.K.; Johnson, R.M.

    1995-01-01

    This paper shows, using computer EMTP simulations, some preliminary results of applying pulse amplitude synthesis and control (PASC) technology to single-source voltage converter systems. The method can be applied to any single terminal pair source with appropriate modifications in power extraction interface and computer control program to match source and load impedance characteristics. The PASC realization as discussed here employs banks of transformers, one bank per phase, in which the primary are connected in parallel through a switch matrix to the dc source. Two opposite polarity primaries per transformer are pulsed alternatively in time to produce an oscillatory sinusoidal output waveform. PASC conversion system capabilities to produce both leading and lagging power factor power output in single-phase and three-phase {Delta} or Y configurations are illustrated. EHTP simulations are used to demonstrate the converter capabilities. Also included are discussions regarding harmonics and potential control strategies to adapt the converter to an application or to minimize harmonics.

  7. System Measures Loads In Bolts

    NASA Technical Reports Server (NTRS)

    Allison, Sidney G.

    1994-01-01

    Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

  8. Dummy load technique for power efficiency estimation in rf discharges

    NASA Astrophysics Data System (ADS)

    Savas, S. E.; Horne, D. E.; Sadowski, R. W.

    1986-07-01

    We have developed a simulated load technique for estimating power dissipation and effective impedance of the discharge which is useful over a wide range of driver frequencies. This is used to calculate the power delivered to the plasma and plasma current for frequencies from 0.12 to 13.56 MHz. This technique allows an efficiency calibration curve to be made for a given match circuit which can be quickly applied to any new discharge condition to give match efficiency.

  9. Research on improvement of power quality of Micro - grid based on SVG pulse load

    NASA Astrophysics Data System (ADS)

    Lv, Chuang; Xie, Pu

    2017-05-01

    Pulse load will make the micro-grid public bus power to produce a high peak pulse due to its cyclical pulsation characteristics,, and make the micro-grid voltage fluctuations, frequency fluctuations, voltage and current distortion, power factor reduction and other adverse effects. In order to suppress the adverse effects of the pulse load on the microgrid and improve the power quality of the microgrid, this paper established the SVG simulation model in Matlab / Simulink environment, the superiority of SVG is verified by comparing the improvement of power quality before and after adding the SVG to microgrid system. The results show that the SVG model can suppress the adverse effects effectively of the pulse load on the microgrid, which is of great value and significance to the reactive power compensation and harmonic suppression of the microgrid.

  10. Solar Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  11. Solar Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  12. Solar Powered Refrigeration System

    NASA Astrophysics Data System (ADS)

    Ewert, Michael K.; Bergeron, David J., III

    2002-09-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  13. Direct current uninterruptible power supply method and system

    DOEpatents

    Sinha, Gautam

    2003-12-02

    A method and system are described for providing a direct current (DC) uninterruptible power supply with the method including, for example: continuously supplying fuel to a turbine; converting mechanical power from the turbine into alternating current (AC) electrical power; converting the AC electrical power to DC power within a predetermined voltage level range; supplying the DC power to a load; and maintaining a DC load voltage within the predetermined voltage level range by adjusting the amount of fuel supplied to the turbine.

  14. POWER GRID DYNAMICS: ENHANCING POWER SYSTEM OPERATION THROUGH PRONY ANALYSIS

    SciTech Connect

    Ray, C.; Huang, Z.

    2007-01-01

    Prony Analysis is a technique used to decompose a signal into a series consisting of weighted complex exponentials and promises to be an effi cient way of recognizing sensitive lines during faults in power systems such as the U.S. Power grid. Positive Sequence Load Flow (PSLF) was used to simulate the performance of a simple two-area-four-generator system and the reaction of the system during a line fault. The Dynamic System Identifi cation (DSI) Toolbox was used to perform Prony analysis and use modal information to identify key transmission lines for power fl ow adjustment to improve system damping. The success of the application of Prony analysis methods to the data obtained from PSLF is reported, and the key transmission line for adjustment is identifi ed. Future work will focus on larger systems and improving the current algorithms to deal with networks such as large portions of the Western Electricity Coordinating Council (WECC) power grid.

  15. Power Systems Development Facility

    SciTech Connect

    Southern Company Services

    2009-01-31

    In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, has routinely demonstrated gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This final report summarizes the results of the technology development work conducted at the PSDF through January 31, 2009. Twenty-one major gasification test campaigns were completed, for a total of more than 11,000 hours of gasification operation. This operational experience has led to significant advancements in gasification technologies.

  16. The Palletized Load System: Just Another Truck?

    DTIC Science & Technology

    1991-12-19

    APPROVAL Student: Major Daniel V. Sulka, US Amy Title of Monograph: The Palletized Load System.... Just Another Truck? __________••._________ , Monograph...Director. Graduate Philip J. Brookes, PHD Degree Program Accepted this _ day of _ _ ,_1991 -- • . , , i I II I__ _ 1991 ABSTRACT THE PALLETIZED LOAD...SYSTEM.... JUST ANOTHER TRUCK? by Major Daniel V. Sulka, USA, 61 pages. This monograph examines the Palletized Load System to determine if it will

  17. Lunar power systems

    NASA Astrophysics Data System (ADS)

    Criswell, D. R.; Waldron, R. D.; Aldrin, B.

    Small areas of the moon's east and west limb surfaces can be transformed into solar collectors and transmitters, furnishing microwave power beam receivers on the moonward side of the earth with large amounts of inexpensive electricity. The receiving antennas would be 6-15 times smaller in area than a terrestrial photovoltaic array of comparable power. The lunar environment is inherently suited to the construction and long term operation of thin film-based systems for the conversion of diffuse sunlight into electricity; lunar soil, moreover, can be readily processed into glasses, ceramics, and agglutinates. The conversion of a 10,000-sq km lunar surface area into power conversion systems would allow the earth to be supplied with more power than it currently consumes.

  18. Fuel-cell powered uninterruptible power supply systems: Design considerations

    NASA Astrophysics Data System (ADS)

    Choi, Woojin; Howze, Jo. W.; Enjeti, Prasad

    A 1-kVA fuel cell powered, line-interactive uninterruptible power supply (UPS) system that employs modular (fuel cell and power converter) blocks is introduced. Two commercially available proton-exchange membrane fuel cell (25-39 V, 500 W) modules together with suitable dc-dc and dc-ac power electronic converter modules are employed. A supercapacitor module is also used to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor (reformers). Further energy stored in the supercapacitor is also utilized to handle a momentary overload such as 200% for a short duration. Due to the absence of batteries, the system satisfies the demand for an environmentally clean source of energy. A complete design that defines the amount of hydrogen storage required for a power outage of 1 h, and the sizing of the supercapacitors for transient load demand is presented for a 1-kVA UPS.

  19. Monitoring Locomotor Load in Soccer: Is Metabolic Power, Powerful?

    PubMed

    Buchheit, M; Manouvrier, C; Cassirame, J; Morin, J-B

    2015-12-01

    The aim of the present study was to examine the validity and reliability of metabolic power (P) estimated from locomotor demands during soccer-specific drills. 14 highly-trained soccer players performed a soccer-specific circuit with the ball (3×1-min bouts, interspersed with 30-s passive recovery) on 2 different occasions. Locomotor activity was monitored with 4-Hz GPSs, while oxygen update (VO2) was collected with a portable gas analyzer. P was calculated using either net VO2 responses and traditional calorimetry principles (PVO2, W.kg(-1)) or locomotor demands (PGPS, W.kg(-1)). Distance covered into different speed, acceleration and P zones was recorded. While PGPS was 29±10% lower than PVO2 (d<- 3) during the exercise bouts, it was 85±7% lower (d<- 8) during recovery phases. The typical error between PGPS vs. PVO2 was moderate: 19.8%, 90% confidence limits: (18.4;21.6). The correlation between both estimates of P was small: 0.24 (0.14;0.33). Very large day-to-day variations were observed for acceleration, deceleration and > 20 W.kg(-1) distances (all CVs > 50%), while average Po2 and PGPS showed CVs < 10%. ICC ranged from very low- (acceleration and > 20 W.kg(-1) distances) to-very high (PVO2). PGPS largely underestimates the energy demands of soccer-specific drills, especially during the recovery phases. The poor reliability of PGPS >20 W.kg(-1) questions its value for monitoring purposes in soccer.

  20. Effect of unloading and loading on power in simulated countermovement and squat jumps.

    PubMed

    Bobbert, Maarten F

    2014-06-01

    In the literature, substantial decreases in power output in jumping have been described for both unloading and loading, and these have been attributed to the intrinsic force-velocity-power relationship of muscle. The purpose of this study was to gain a solid understanding of how and why unloading and loading affect power output during jumping. Vertical jumps were simulated with a model of the musculoskeletal system, consisting of four rigid segments actuated by six muscles. Muscle stimulation over time was optimized to ensure maximal performance in each loading condition. It was found that, in contrast to what is reported in the literature, unloading by an extra vertical force of -60% of body weight caused a small increase in the peak of the rate of change of the effective energy of the center of mass (dEeff/dt). Loading by an extra vertical force of +60% of body weight caused a decrease in peak dEeff/dt, but this decrease was much smaller than that described in the literature. The small variations in peak dEeff/dt among loading conditions in the simulated jumps were only in part due to the intrinsic force-velocity-power relationship of muscle. Why did the effects of unloading and loading in the simulation model deviate from effects reported in subjects? One possible explanation is that subjects tend to make a smaller countermovement when loaded; in the simulation model, making a smaller countermovement caused a major reduction in peak dEeff/dt. A second possible explanation is that subjects cannot quickly optimize their control and therefore produce submaximal power output in unfamiliar loading conditions. The effects of unloading and loading are due only in part to the intrinsic force-velocity-power relationship of muscle.

  1. Phase protection system for ac power lines

    NASA Technical Reports Server (NTRS)

    Wong, W. J. (Inventor)

    1974-01-01

    The system described provides protection for phase sensitive loads from being or remaining connected to ac power lines whenever a phase reversal occurs. It comprises a solid state phase detection circuit, a dc power relay circuit, an ac-to-dc converter for energizing the relay circuit, and a bistable four terminal transducer coupled between the phase detection circuit and the power relay circuit, for controlling both circuits.

  2. Load and Rate of Change of Load Detection System.

    DTIC Science & Technology

    The present invention relates to a system for detecting and recording the level and rate of change of landing loads in the struts of aircraft landing...to a minimum pressure to record the level and rate of change of pressure detected by the sensor.

  3. Engineers stretch power delivery systems with technology

    SciTech Connect

    Beaty, W.

    1996-09-01

    Efforts to increase electric power transmission capacity by four major distributors are described in the article. The Pennsylvania-Jersey-Maryland Power Pool restructuring for operation as an independent system operator is discussed, and equipment upgrades are briefly outlined. The Inex project of American Electric Power, which uses a unified power flow controller to operator a flexible alternating current transmission system (FACTS), is highlighted. Options being considered by Electricite de France are directed at making full use of existing resources; these include optimizing conductor alloy materials and shapes, operating at maximum conductor temperatures, and using FACTS technology to maintain voltages, adjust power flows, and improve network stability. Increasing capacity in the National Grid Company (NGC) system in the United Kingdom involves a combination of load sharing according to thermal capabilities. Technical considerations of NGCs measures to more evenly match load flows to line ratings are also discussed.

  4. Laser satellite power systems

    SciTech Connect

    Walbridge, E.W.

    1980-01-01

    A laser satellite power system (SPS) converts solar power captured by earth-orbiting satellites into electrical power on the earth's surface, the satellite-to-ground transmission of power being effected by laser beam. The laser SPS may be an alternative to the microwave SPS. Microwaves easily penetrate clouds while laser radiation does not. Although there is this major disadvantage to a laser SPS, that system has four important advantages over the microwave alternative: (1) land requirements are much less, (2) radiation levels are low outside the laser ground stations, (3) laser beam sidelobes are not expected to interfere with electromagnetic systems, and (4) the laser system lends itself to small-scale demonstration. After describing lasers and how they work, the report discusses the five lasers that are candidates for application in a laser SPS: electric discharge lasers, direct and indirect solar pumped lasers, free electron lasers, and closed-cycle chemical lasers. The Lockheed laser SPS is examined in some detail. To determine whether a laser SPS will be worthy of future deployment, its capabilities need to be better understood and its attractiveness relative to other electric power options better assessed. First priority should be given to potential program stoppers, e.g., beam attenuation by clouds. If investigation shows these potential program stoppers to be resolvable, further research should investigate lasers that are particularly promising for SPS application.

  5. Analytical tool requirements for power system restoration

    SciTech Connect

    Adibi, M.M. ); Borkoski, J.N. ); Kafka, R.J. )

    1994-08-01

    This paper is one of series presented by Power System Restoration Working Group (SRWG) on behalf of the System, Operation Subcommittee with the intent of focusing industry attention on power system restoration. In this paper a set of analytical tools is specified which together describe the static, transient and dynamic behavior of a power system during restoration. These tools are identified and described for restoration planning, training and operation. Their applications cover all stages of restoration including pre-disturbance condition, post-disturbance status, post-restoration target system, and minimization of unserved loads. The paper draws on the previous reports by the SRWG.

  6. Distributed Power System for Microsatellites

    DTIC Science & Technology

    2004-12-15

    bus voltage and output current and imple- ments a peak- power - tracking algorithm. Thus if an increase in current demand from the PWM DC- DC converter...the ring bus should be selected to directly power the satellite’s largest load. The solar array controller must have a peak- power - tracking algorithm to

  7. Integrated power system

    SciTech Connect

    Waddington, C.

    1987-10-13

    An integrated power system is described for transmitting power from a gas turbine engine, including a gas producer and a free turbine engine, to the driving elements of a vehicle comprising: a pair of independent output shafts; a pair of combining planetary gear systems, each being drivingly coupled to an associated one of the output shafts; a variable speed transmission drivingly coupled to the free power turbine; drive means operatively connecting the transmission and each of the combining planetary gear systems; steering means operatively coupled to each of the combining planetary gear systems for selectively driving at least one of the combining planetary gear systems; the steering means including a variable displacement hydraulic motor in driving engagement with the planetary gear systems and an hydraulic pump in driving engagement with the transmission for supplying fluid under pressure to the hydraulic motor to thereby effect steering of the vehicle; a fuel control for controlling the power output of the gas turbine engine; and an adjustable relief valve operatively interposed between the hydraulic motor and the hydraulic pump, the valve being responsive to the fuel control to establish a maximum fluid pressure imparted by the hydraulic pump to the hydraulic motor.

  8. Eigenfrequency of Hydraulic Systems of Loading Device

    NASA Astrophysics Data System (ADS)

    Vašina, Martin; Hružík, Lumír; Bureček, Adam

    2016-03-01

    Eigenfrequency of hydraulic systems belongs to important dynamic quantities. If the excitation frequency of a given hydraulic system is equal to the system eigenfrequency, high-amplitude pressure and flow pulsations can arise. It has a negative influence on load of hydraulic elements, system tightness etc. For this reason it is necessary to eliminate the operation of the hydraulic system at its eigenfrequency. The paper deals with experimental determination of the system eigenfrequency in various operating modes of the investigated loading device.

  9. Compensation of Reactive Power of Isolated Wind-Diesel Hybrid Power Systems

    NASA Astrophysics Data System (ADS)

    Sharma, P.; Bhatti, T. S.; Ramakrishna, K. S. S.

    2012-03-01

    This paper presents the automatic reactive power control of an isolated wind-diesel hybrid power system with a synchronous generator (SG) for a diesel genset and an induction generator (IG) with wind energy conversion systems (WECS) to generate electricity. To reduce the gap between reactive power generation and demand, a variable source of reactive power is used such as static synchronous compensator (STATCOM). The mathematical model of the system based on reactive power flow equations is developed. Three examples of the wind-diesel hybrid power systems are considered with different wind power generation capacities to study the effect of the wind power generation on the system performance. The study is based on small signal analysis by considering IEEE type-1 excitation system for the SG. The paper also shows the transient performance of the hybrid systems for 1 % step increase in reactive power load and 1 % step increase in reactive power load plus 1 % step increase in input wind power.

  10. The physics of power systems operation

    NASA Astrophysics Data System (ADS)

    Ohler, C.

    2015-08-01

    The article explains the operation of power systems from the point of view of physics. Physicists imagine things, rather than in terms of impedances and circuits, in terms of fields and energy conversions. The account is concrete and simple. The use of alternating current entails the issue of reactive power. Reactive power consists of energy that oscillates between electrical and magnetic fields, it flows on top of the active power which carries the useful energy. The control of active and reactive power is essential for the power system's reliable operation. The frequency of a power system is the same everywhere. The stability of the frequency indicates that generation and demand of active power are equal, a decline in frequency indicates a lack of generation relative to the demand. Adapting the electrical power injected into the system is the way of frequency control. Because of the parasitic inductances and capacitances of overhead lines, cables, and transformers, the voltage at different locations of the power system depends on the load. The voltage is regulated by the combined action of generator excitation, transformer tap changers and series compensation in order to provide consumers with a stable voltage supply. The integration of solar cells and wind turbines into the power system poses some challenges. But the power system is able to accommodate large amounts of fluctuating renewable power generation if the right complementary measures are taken.

  11. Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading

    DOEpatents

    Perez, Richard

    2003-04-01

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

  12. Mini-Scale Power Distribution Network Feeding Trapezoidal-Wave Voltages to Power Electronic Loads with Diode Rectifiers

    NASA Astrophysics Data System (ADS)

    Noguchi, Toshihiko; Imoto, Masaru; Sato, Yoshikazu

    This paper proposes a novel three-phase power distribution system feeding trapezoidal voltages to various power electronic loads with diode rectifier front-ends. The network distributes trapezoidal voltages generated by synchronous superposition of wave-shaping voltages onto sinusoidal voltages available from a utility power grid. The power distribution by the trapezoidal voltages allows reducing harmonics of the line currents without electronic switching devices because of a spontaneously widened conduction period of the current waveforms. The reduction of the harmonic currents also contributes to improve total power factor at the load input terminals and efficiency of the power transmission cables. Since the diodes of the rectifiers successively commutate the trapezoidal waves during periods of their flat parts, not only total harmonic distortion of the currents is improved, but also voltage ripple across the dc-buses of the rectifiers can effectively be reduced with less filter capacitors. In addition, the system offers an uninterruptible power supply function by immediately changing its outputs from the wave-shaping voltages to the trapezoidal voltages when interruption occurs in the power grid. In this paper, a prototype of the system is experimentally examined from various angles of operating characteristics and test results are presented to prove feasibility of the proposed system.

  13. Power line detection system

    DOEpatents

    Latorre, Victor R.; Watwood, Donald B.

    1994-01-01

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

  14. Power line detection system

    DOEpatents

    Latorre, V.R.; Watwood, D.B.

    1994-09-27

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

  15. TOPEX/Poseidon electrical power system -- Performance

    SciTech Connect

    Sherwood, R.; Deligiannis, F.

    1996-12-31

    This paper shows that the power system performance (batteries, solar array, power regulator) on-board the TOPEX/Poseidon satellite has met or exceeded pre-launch predictions, and has successfully managed the performance of NiCd batteries which had shown anomalous performance on other missions such as UARS and GRO. The battery performance is addressed through the following parameters: end-of-discharge voltage, peak charge current, charge to discharge ratio, and voltage differential. The solar array performance discussion includes voltage, current and power. There is also a discussion of the power regulator efficiency and the satellite load power history.

  16. Power variables and bilateral force differences during unloaded and loaded squat jumps in high performance alpine ski racers.

    PubMed

    Patterson, Carson; Raschner, Christian; Platzer, Hans-Peter

    2009-05-01

    The purpose of this paper was to investigate the power-load relationship and to compare power variables and bilateral force imbalances between sexes with squat jumps. Twenty men and 17 women, all members of the Austrian alpine ski team (junior and European Cup), performed unloaded and loaded (barbell loads equal to 25, 50, 75, and 100% body weight [BW]) squat jumps with free weights using a specially designed spotting system. Ground reaction force records from 2 force platforms were used to calculate relative average power (P), relative average power in the first 100 ms of the jump (P01), relative average power in the first 200 ms of the jump (P02), jump height, percentage of best jump height (%Jump), and maximal force difference between dominant and nondominant leg (Fmaxdiff). The men displayed significantly higher values at all loads for P and jump height (p < 0.05). No significant differences were found in P01. The men had significantly higher P02 at all loads except 75% BW). Maximum P was reached at light loads (men at 25% BW and women at 0% BW), and P decreased uniformly thereafter. Individual power-load curves show a deflection point. It is proposed that the load where the power-load deflection point occurs be used as the power training load and not the load at which maximum P is reached. It is also proposed that loads not be described in %1-repetition maximum (RM), but as %BW. This system can be used to safely assess and train power with loaded jumps and free weights.

  17. UNISAT-3 Power System

    NASA Astrophysics Data System (ADS)

    Santoni, Fabio; Piergentili, Fabrizio; Bulgarelli, Fabio; Graziani, Filippo

    2005-05-01

    An overview of the UNISAT-3 microsatellite power subsystem is given. This is an educational, low weight and low cost microsatellite designed, built, launched and operated in space by students and professors of Scuola di Ingegneria Aerospaziale, at University of Rome "La Sapienza". The satellite power system is based on terrestrial technology solar arrays and NiCd batteries. The microsatellite hosts other solar arrays, including multi-junction solar cells and mono- crystalline silicon high efficiency solar cells, in order to compare their behaviour in orbit. Moreover a MPPT (Maximum Power Point Tracking ) system has been designed and tested, and it is a technological payload of UNISAT-3. The MPPT design follows the studies performed in the field of solar powered racing cars, with modifications to make the system suitable for use in space. The system design, numerical simulation and hardware ground testing are described in the paper. The experiment and the performance evaluation criterion are described, together with the preliminary results of the first eight months of operation in orbit.

  18. Short-term load and wind power forecasting using neural network-based prediction intervals.

    PubMed

    Quan, Hao; Srinivasan, Dipti; Khosravi, Abbas

    2014-02-01

    Electrical power systems are evolving from today's centralized bulk systems to more decentralized systems. Penetrations of renewable energies, such as wind and solar power, significantly increase the level of uncertainty in power systems. Accurate load forecasting becomes more complex, yet more important for management of power systems. Traditional methods for generating point forecasts of load demands cannot properly handle uncertainties in system operations. To quantify potential uncertainties associated with forecasts, this paper implements a neural network (NN)-based method for the construction of prediction intervals (PIs). A newly introduced method, called lower upper bound estimation (LUBE), is applied and extended to develop PIs using NN models. A new problem formulation is proposed, which translates the primary multiobjective problem into a constrained single-objective problem. Compared with the cost function, this new formulation is closer to the primary problem and has fewer parameters. Particle swarm optimization (PSO) integrated with the mutation operator is used to solve the problem. Electrical demands from Singapore and New South Wales (Australia), as well as wind power generation from Capital Wind Farm, are used to validate the PSO-based LUBE method. Comparative results show that the proposed method can construct higher quality PIs for load and wind power generation forecasts in a short time.

  19. Object-oriented programming, C++ and power system simulation

    SciTech Connect

    Zhou, E.Z.

    1996-02-01

    Application of OOP concepts and the C++ programming language to power system simulation has been explored. An efficient platform for power system simulation applications has been proposed. By emulating a physical power lab, a generic power network container has been built. A module, which can be used to solve sparse matrix equations of any data types, has been implemented. Two load flow applications: a dc load flow and an ac load flow have been discussed. It is found that the OOP based C++ load flow programs are as efficient as their non-OOP counterparts.

  20. Heavy Vehicle Essential Power Systems Workshop

    SciTech Connect

    Susan Rogers

    2001-12-12

    Essential power is a crosscutting technology area that addresses the efficient and practical management of electrical and thermal requirements on trucks. Essential Power Systems: any function on the truck, that is not currently involved in moving the truck, and requires electrical or mechanical energy; Truck Lights; Hotel Loads (HVAC, computers, appliances, lighting, entertainment systems); Pumps, starter, compressor, fans, trailer refrigeration; Engine and fuel heating; and Operation of power lifts and pumps for bulk fluid transfer. Transition from ''belt and gear driven'' to auxiliary power generation of electricity - ''Truck Electrification'' 42 volts, DC and/ or AC; All electrically driven auxiliaries; Power on demand - manage electrical loads; Benefits include: increased fuel efficiency, reduced emission both when truck is idling and moving down the road.

  1. Suboptimal greedy power allocation schemes for discrete bit loading.

    PubMed

    Al-Hanafy, Waleed; Weiss, Stephan

    2013-01-01

    We consider low cost discrete bit loading based on greedy power allocation (GPA) under the constraints of total transmit power budget, target BER, and maximum permissible QAM modulation order. Compared to the standard GPA, which is optimal in terms of maximising the data throughput, three suboptimal schemes are proposed, which perform GPA on subsets of subchannels only. These subsets are created by considering the minimum SNR boundaries of QAM levels for a given target BER. We demonstrate how these schemes can significantly reduce the computational complexity required for power allocation, particularly in the case of a large number of subchannels. Two of the proposed algorithms can achieve near optimal performance including a transfer of residual power between subsets at the expense of a very small extra cost. By simulations, we show that the two near optimal schemes, while greatly reducing complexity, perform best in two separate and distinct SNR regions.

  2. Suboptimal Greedy Power Allocation Schemes for Discrete Bit Loading

    PubMed Central

    2013-01-01

    We consider low cost discrete bit loading based on greedy power allocation (GPA) under the constraints of total transmit power budget, target BER, and maximum permissible QAM modulation order. Compared to the standard GPA, which is optimal in terms of maximising the data throughput, three suboptimal schemes are proposed, which perform GPA on subsets of subchannels only. These subsets are created by considering the minimum SNR boundaries of QAM levels for a given target BER. We demonstrate how these schemes can significantly reduce the computational complexity required for power allocation, particularly in the case of a large number of subchannels. Two of the proposed algorithms can achieve near optimal performance including a transfer of residual power between subsets at the expense of a very small extra cost. By simulations, we show that the two near optimal schemes, while greatly reducing complexity, perform best in two separate and distinct SNR regions. PMID:24501578

  3. Analysis of large power systems

    NASA Technical Reports Server (NTRS)

    Dommel, H. W.

    1975-01-01

    Computer-oriented power systems analysis procedures in the electric utilities are surveyed. The growth of electric power systems is discussed along with the solution of sparse network equations, power flow, and stability studies.

  4. Prospects of thermionic power systems

    NASA Technical Reports Server (NTRS)

    Shimada, K.

    1978-01-01

    Potential thermionic power systems for space or terrestrial applications are described so that the development goals can be clearly identified. The thermionic power systems considered are a space nuclear power system, a fossil-fuel thermionic topping steam power system, a solar thermionic topping steam power system, and advanced systems. Attention is given to a discussion of the current status of technology development in thermionic converters and associated elements in power systems. Future prospects of thermionic power systems are also discussed. It is concluded that thermionic conversion has a great potential for a variety of applications.

  5. Power systems testing

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The Space Station Freedom (SSF) will give the U.S. a permanent manned presence in space in 1999. The SSF underwent its final design concept in 1991. Launches of hardware will begin in late 1995, and the SSF will become operational in the man tended configuration in 1997. Additional Space Shuttle flights between 1997 and 1999 will complete the SSF. Along with international partners, a crew of four astronauts will conduct long-term experimentation in the microgravity environment of the orbiting spacecraft. Lewis Research Center, along with its prime contractor, will provide the electrical power system (EPS) for SSF. Two major testing facilities at the Lewis Research Center will support the Lewis EPS. The Power Systems Facility provides test beds for life testing the station batteries and the power management distribution system testbed. This testbed simulates two channels of the EPS. The Space Power Facility at the Lewis Plum Brook Station is the largest vacuum chamber in the world. Within this chamber, a simulated space environment, testing of full-size EPS components will occur.

  6. Analysis of Wind Power and Load Data at Multiple Time Scales

    SciTech Connect

    Coughlin, Katie; Eto, J.H.

    2010-12-20

    In this study we develop and apply new methods of data analysis for high resolution wind power and system load time series, to improve our understanding of how to characterize highly variable wind power output and the correlations between wind power and load. These methods are applied to wind and load data from the ERCOT region, and wind power output from the PJM and NYISO areas. We use a wavelet transform to apply mathematically well-defined operations of smoothing and differencing to the time series data. This approach produces a set of time series of the changes in wind power and load (or ?deltas?), over a range of times scales from a few seconds to approximately one hour. A number of statistical measures of these time series are calculated. We present sample distributions, and devise a method for fitting the empirical distribution shape in the tails. We also evaluate the degree of serial correlation, and linear correlation between wind and load. Our examination of the data shows clearly that the deltas do not follow a Gaussian shape; the distribution is exponential near the center and appears to follow a power law for larger fluctuations. Gaussian distributions are frequently used in modeling studies. These are likely to over-estimate the probability of small to moderate deviations. This in turn may lead to an over-estimation of the additional reserve requirement (hence the cost) for high penetration of wind. The Gaussian assumption provides no meaningful information about the real likelihood of large fluctuations. The possibility of a power law distribution is interesting because it suggests that the distribution shape for of wind power fluctuations may become independent of system size for large enough systems.

  7. Heatpipe power system development

    SciTech Connect

    Houts, M.G.; Poston, D.I.

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The objective of the project was to develop a design approach that could enable the development of near-term, low-cost, space fission-power systems. Sixteen desired attributes were identified for such systems and detailed analyses were performed to verify that they are feasible. Preliminary design work was performed on one concept, the Heatpipe Power system (HPS). As a direct result of this project, funding was obtained from the National Aeronautics and Space Administration to build and test an HPS module. The module tests went well, and they now have funding to build a bimodal module.

  8. Impact evaluation of conducted UWB transients on loads in power-line networks

    NASA Astrophysics Data System (ADS)

    Li, Bing; Månsson, Daniel

    2017-09-01

    Nowadays, faced with the ever-increasing dependence on diverse electronic devices and systems, the proliferation of potential electromagnetic interference (EMI) becomes a critical threat for reliable operation. A typical issue is the electronics working reliably in power-line networks when exposed to electromagnetic environment. In this paper, we consider a conducted ultra-wideband (UWB) disturbance, as an example of intentional electromagnetic interference (IEMI) source, and perform the impact evaluation at the loads in a network. With the aid of fast Fourier transform (FFT), the UWB transient is characterized in the frequency domain. Based on a modified Baum-Liu-Tesche (BLT) method, the EMI received at the loads, with complex impedance, is computed. Through inverse FFT (IFFT), we obtain time-domain responses of the loads. To evaluate the impact on loads, we employ five common, but important quantifiers, i.e., time-domain peak, total signal energy, peak signal power, peak time rate of change and peak time integral of the pulse. Moreover, to perform a comprehensive analysis, we also investigate the effects of the attributes (capacitive, resistive, or inductive) of other loads connected to the network, the rise time and pulse width of the UWB transient, and the lengths of power lines. It is seen that, for the loads distributed in a network, the impact evaluation of IEMI should be based on the characteristics of the IEMI source, and the network features, such as load impedances, layout, and characteristics of cables.

  9. Microwave power transmission system wherein level of transmitted power is controlled by reflections from receiver

    NASA Technical Reports Server (NTRS)

    Robinson, W. J., Jr. (Inventor)

    1974-01-01

    A microwave, wireless, power transmission system is described in which the transmitted power level is adjusted to correspond with power required at a remote receiving station. Deviations in power load produce an antenna impedance mismatch causing variations in energy reflected by the power receiving antenna employed by the receiving station. The variations in reflected energy are sensed by a receiving antenna at the transmitting station and used to control the output power of a power transmitter.

  10. High power connection system

    SciTech Connect

    Schaefer, Christopher E.; Beer, Robert C.; McCall, Mark D.

    2000-01-01

    A high power connection system adapted for automotive environments which provides environmental and EMI shielding includes a female connector, a male connector, and a panel mount. The female connector includes a female connector base and a snap fitted female connector cover. The male connector includes a male connector base and a snap fitted male connector cover. The female connector base has at least one female power terminal cavity for seatably receiving a respective female power terminal. The male connector base has at least one male power terminal cavity for seatably receiving a respective male power terminal. The female connector is covered by a cover seal and a conductive shroud. A pair of lock arms protrude outward from the front end of the male connector base, pass through the panel mount and interface with a lever of a lever rotatably connected to the shroud to thereby mechanically assist mating of the male and female connectors. Safety terminals in the male and female connectors provide a last-to-connect-first-to-break connection with an HVIL circuit.

  11. Power conditioning unit for photovoltaic power systems

    NASA Astrophysics Data System (ADS)

    Beghin, G.; Nguyen Phuoc, V. T.

    Operational features and components of a power conditioning unit for interconnecting solar cell module powers with a utility grid are outlined. The two-stage unit first modifies the voltage to desired levels on an internal dc link, then inverts the current in 2 power transformers connected to a vector summation control to neutralize harmonic distortion up to the 11th harmonic. The system operates in parallel with the grid with extra inductors to absorb line-to-line voltage and phase differences, and permits peak power use from the PV array. Reactive power is gained internally, and a power system controller monitors voltages, frequencies, and currents. A booster preregulator adjusts the input voltage from the array to provide voltage regulation for the inverter, and can commutate 450 amps. A total harmonic distortion of less than 5 percent is claimed, with a rating of 5 kVA, 50/60 Hz, 3-phase, and 4-wire.

  12. Autonomously managed electrical power systems

    NASA Technical Reports Server (NTRS)

    Callis, Charles P.

    1986-01-01

    The electric power systems for future spacecraft such as the Space Station will necessarily be more sophisticated and will exhibit more nearly autonomous operation than earlier spacecraft. These new power systems will be more reliable and flexible than their predecessors offering greater utility to the users. Automation approaches implemented on various power system breadboards are investigated. These breadboards include the Hubble Space Telescope power system test bed, the Common Module Power Management and Distribution system breadboard, the Autonomusly Managed Power System (AMPS) breadboard, and the 20 kilohertz power system breadboard. Particular attention is given to the AMPS breadboard. Future plans for these breadboards including the employment of artificial intelligence techniques are addressed.

  13. The equal load-sharing model of cascade failures in power grids

    NASA Astrophysics Data System (ADS)

    Scala, Antonio; De Sanctis Lucentini, Pier Giorgio

    2016-11-01

    Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing power demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into ;super-grids;.

  14. A Load Frequency Control in an Off-Grid Sustainable Power System Based on a Parameter Adaptive PID-Type Fuzzy Controller

    NASA Astrophysics Data System (ADS)

    Ronilaya, Ferdian; Miyauchi, Hajime

    2014-10-01

    This paper presents a new implementation of a parameter adaptive PID-type fuzzy controller (PAPIDfc) for a grid-supporting inverter of battery to alleviate frequency fluctuations in a wind-diesel power system. A variable speed wind turbine that drives a permanent magnet synchronous generator is assumed for demonstrations. The PAPIDfc controller is built from a set of control rules that adopts the droop method and uses only locally measurable frequency signal. The output control signal is determined from the knowledge base and the fuzzy inference. The input-derivative gain and the output-integral gain of the PAPIDfc are tuned online. To ensure safe battery operating limits, we also propose a protection scheme called intelligent battery protection (IBP). Several simulation experiments are performed by using MATLAB®/SimPowersystems™. Next, to verify the scheme's effectiveness, the simulation results are compared with the results of conventional controllers. The results demonstrate the effectiveness of the PAPIDfc scheme to control a grid-supporting inverter of the battery in the reduction of frequency fluctuations.

  15. Grid-Tied Photovoltaic Power System

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.

    2011-01-01

    A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM

  16. Power systems facility

    NASA Technical Reports Server (NTRS)

    1989-01-01

    In 1984, the President directed NASA to undertake the development of Space Station Freedom, the next step in a broad-based U.S. civil space program to develop space-flight capabilities and to exploit space for scientific, technological, and commercial purposes. Under that direction, NASA awarded contracts in 1985 for concept definition and preliminary design studies. Those studies have been completed and the Space Station Freedom Program is now in the final design and development phase, leading to a permanently manned space station that will be operational in the mid-1990's. Here at the Lewis Research Center, with Rocketdyne, we are developing and building the S.S. Freedom electric power system (EPS) hardware and software. A major portion of the EPS will be tested at Lewis. The Power Systems Facility was specifically designed for testing the EPS and uses the latest in testing equipment.

  17. Displacement-load force-perceived weight relationships in lifting objects with power-assist

    NASA Astrophysics Data System (ADS)

    Rahman, S. M. Mizanoor; Ikeura, Ryojun; Nobe, Masaya; Sawai, Hideki

    2010-01-01

    This paper deals with the design of a 1-DOF power assist system (PAS) for lifting objects in vertical direction based on a hypothesis that pertains to operator's weight perception. We particularly studied the relationships among object's displacement, load force (vertical lifting force) and perceived weight for the objects lifted with the PAS. We also compared the load force features for power-assist-lifted objects to that for manually lifted objects for equal heaviness. Finally, we proposed using the findings to develop human-friendly PASs for lifting heavy objects in industries such as construction, military operations, manufacturing and assembly, logistics and transport, mining etc.

  18. Displacement-load force-perceived weight relationships in lifting objects with power-assist

    NASA Astrophysics Data System (ADS)

    Rahman, S. M. Mizanoor; Ikeura, Ryojun; Nobe, Masaya; Sawai, Hideki

    2009-12-01

    This paper deals with the design of a 1-DOF power assist system (PAS) for lifting objects in vertical direction based on a hypothesis that pertains to operator's weight perception. We particularly studied the relationships among object's displacement, load force (vertical lifting force) and perceived weight for the objects lifted with the PAS. We also compared the load force features for power-assist-lifted objects to that for manually lifted objects for equal heaviness. Finally, we proposed using the findings to develop human-friendly PASs for lifting heavy objects in industries such as construction, military operations, manufacturing and assembly, logistics and transport, mining etc.

  19. Application of Classification Methods for Forecasting Mid-Term Power Load Patterns

    NASA Astrophysics Data System (ADS)

    Piao, Minghao; Lee, Heon Gyu; Park, Jin Hyoung; Ryu, Keun Ho

    Currently an automated methodology based on data mining techniques is presented for the prediction of customer load patterns in long duration load profiles. The proposed approach in this paper consists of three stages: (i) data preprocessing: noise or outlier is removed and the continuous attribute-valued features are transformed to discrete values, (ii) cluster analysis: k-means clustering is used to create load pattern classes and the representative load profiles for each class and (iii) classification: we evaluated several supervised learning methods in order to select a suitable prediction method. According to the proposed methodology, power load measured from AMR (automatic meter reading) system, as well as customer indexes, were used as inputs for clustering. The output of clustering was the classification of representative load profiles (or classes). In order to evaluate the result of forecasting load patterns, the several classification methods were applied on a set of high voltage customers of the Korea power system and derived class labels from clustering and other features are used as input to produce classifiers. Lastly, the result of our experiments was presented.

  20. Analysis on capability of load following for nuclear power plants abroad and its enlightenment

    NASA Astrophysics Data System (ADS)

    Zheng, Kuan; Zhang, Fu-qiang; Deng, Ting-ting; Zhang, Jin-fang; Hao, Weihua

    2017-01-01

    With the acceleration adjustment of China’s energy structure, the development of nuclear power plants in China has been going back to the fast track. While as the trend of slowing electric power demand is now unmistakable, it enforces the power system to face much greater pressure in some coastal zones where the nuclear power plants are of a comparative big proportion, such as Fujian province and Liaoning province. In this paper, the capability of load following of nuclear power plants of some developed countries with high proportion of nuclear power generation such as France, US and Japan are analysed, also from the aspects including the safety, the economy and their practical operation experience is studied. The feasibility of nuclear power plants to participate in the peak regulation of system is also studied and summarized. The results of this paper could be of good reference value for the China’s nuclear power plants to participate in system load following, and also of great significance for the development of the nuclear power plants in China.

  1. Method to Estimate Long-term Change of Heat and Electric Power Daily Load Curves in Japan

    NASA Astrophysics Data System (ADS)

    Oda, Takuya; Akisawa, Atushi; Kashiwagi, Takao

    The rapid spread of CHP systems will put pressure on the regional power system to requiring an examination of the power and heat output of CHP systems. When considering the country-wide potential of the CHP system one should examine such system in coordination with the grid power system. It is essential to calculate the heat and power demand at end-use level. In the paper, annual heat and power demands of end-use sectors are forecast to the year 2025 based on 20 year data. Regression analysis is used. Estimated annual demands are divided into the seasonal hourly demands considering demand characteristics. Daily load curves of heat and power demands are determined for the Japanese end-use sectors, and the annual changes of such demands are shown by duration curves of heat to power ratios. Moreover, the grid power daily load curves are computed numerically from the estimated heat and power demands at manufacturing, residential and commercial sectors. Such load curves also consider self-generated power at manufacturing industry and own consumption of the grid power. Estimating heat and power demands allow for a joint analysis between the power system and the future phasing in of CHP systems.

  2. Space station electrical power distribution analysis using a load flow approach

    NASA Technical Reports Server (NTRS)

    Emanuel, Ervin M.

    1987-01-01

    The space station's electrical power system will evolve and grow in a manner much similar to the present terrestrial electrical power system utilities. The initial baseline reference configuration will contain more than 50 nodes or busses, inverters, transformers, overcurrent protection devices, distribution lines, solar arrays, and/or solar dynamic power generating sources. The system is designed to manage and distribute 75 KW of power single phase or three phase at 20 KHz, and grow to a level of 300 KW steady state, and must be capable of operating at a peak of 450 KW for 5 to 10 min. In order to plan far into the future and keep pace with load growth, a load flow power system analysis approach must be developed and utilized. This method is a well known energy assessment and management tool that is widely used throughout the Electrical Power Utility Industry. The results of a comprehensive evaluation and assessment of an Electrical Distribution System Analysis Program (EDSA) is discussed. Its potential use as an analysis and design tool for the 20 KHz space station electrical power system is addressed.

  3. Test and evaluation of load converter topologies used in the Space Station Freedom Power Management and distribution DC test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station Freedom dc Electrical Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switchmode converter, and a switching full-bridge forward converter. The topology, operation principles, and tests results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  4. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  5. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    NASA Technical Reports Server (NTRS)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  6. Hybrid robust predictive optimization method of power system dispatch

    DOEpatents

    Chandra, Ramu Sharat; Liu, Yan; Bose, Sumit; de Bedout, Juan Manuel

    2011-08-02

    A method of power system dispatch control solves power system dispatch problems by integrating a larger variety of generation, load and storage assets, including without limitation, combined heat and power (CHP) units, renewable generation with forecasting, controllable loads, electric, thermal and water energy storage. The method employs a predictive algorithm to dynamically schedule different assets in order to achieve global optimization and maintain the system normal operation.

  7. Concentrating Solar Power Systems

    NASA Astrophysics Data System (ADS)

    Pitz-Paal, R.

    2017-07-01

    Development of Concentrating Solar Power Systems has started about 40 years ago. A first commercial implementation was performed between 1985 and 1991 in California. However, a drop in gas prices caused a longer period without further deployment. It was overcome in 2007 when new incentive schemes for renewables in Spain and the US enabled a commercial restart. In 2016, almost 100 commercial CSP plants with more than 5GW are installed worldwide. This paper describes the physical background of CSP technology, its technical characteristics and concepts. Furthermore, it discusses system performances, cost structures and the expected advancement.

  8. Lunar power systems

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The findings of a study on the feasibility of several methods of providing electrical power for a permanently manned lunar base are provided. Two fundamentally different methods for lunar electrical power generation are considered. One is the use of a small nuclear reactor and the other is the conversion of solar energy to electricity. The baseline goal was to initially provide 300 kW of power with growth capability to one megawatt and eventually to 10 megawatts. A detailed, day by day scenario for the establishment, build-up, and operational activity of the lunar base is presented. Also presented is a conceptual approach to a supporting transportation system which identifies the number, type, and deployment of transportation vehicles required to support the base. An approach to the use of solar cells in the lunar environment was developed. There are a number of heat engines which are applicable to solar/electric conversions, and these are examined. Several approaches to energy storage which were used by the electric power utilities were examined and those which could be used at a lunar base were identified.

  9. Lunar power systems

    NASA Astrophysics Data System (ADS)

    1986-12-01

    The findings of a study on the feasibility of several methods of providing electrical power for a permanently manned lunar base are provided. Two fundamentally different methods for lunar electrical power generation are considered. One is the use of a small nuclear reactor and the other is the conversion of solar energy to electricity. The baseline goal was to initially provide 300 kW of power with growth capability to one megawatt and eventually to 10 megawatts. A detailed, day by day scenario for the establishment, build-up, and operational activity of the lunar base is presented. Also presented is a conceptual approach to a supporting transportation system which identifies the number, type, and deployment of transportation vehicles required to support the base. An approach to the use of solar cells in the lunar environment was developed. There are a number of heat engines which are applicable to solar/electric conversions, and these are examined. Several approaches to energy storage which were used by the electric power utilities were examined and those which could be used at a lunar base were identified.

  10. Multivoltage high power electrical power system

    NASA Astrophysics Data System (ADS)

    Hyvarinen, W. E.

    Applications are being identified where the optimum aircraft electrical system may not be the conventional 400 Hz approach. The requirements for a multivoltage high power airborne electrical system are presented. The methodology used to define and evaluate operating parameters, system configuration and control philosophy are presented. The approach recommended for this application is described.

  11. Three-Phase Load Flow for Unbalanced Systems.

    NASA Astrophysics Data System (ADS)

    Chang, Yih-Ping

    Traditionally, transmission systems are assumed to be balanced in power system analysis. A single phase positive sequence circuit is used in transmission system load flow analysis to simplify the study. However, when untransposed transmission lines are used in a power system due to economic considerations, space limitation; or when large unbalanced load is on the system; or when an unbalance contingency occurs on the system, this assumption may not hold true. The unbalance condition in some isolated systems are so precarious that disaster can result. One such incident occurred on a generator unit of the third nuclear power plant of Taipower in 1985. In that particular case, the turbine blades were broken and a spark ignited the liquid hydrogen when the blade vibration resonated with the 120.5 Hz rotor current. One cause of this rotor current generation is system unbalance. The unbalanced three-phase load flow program is needed in today's power system analysis. An advanced three-phase unbalanced transmission load flow program, capable of locating the unbalanced problem of large electric network systems, was proposed to be developed and tested in this research. Features of this program include simultaneous power flow of multiple voltage levels on an individual phase basis; PV bus generator, cogenerator, transformer simulation, and load modeling. It is found that delta-grounded wye step-up transformer reduces the convergence speed greatly. When too many delta-grounded wye step-up transformers exist in a large scale system and a quick approximate result of the unbalance conditions is needed, these step-up transformers can be substituted by grounded-wye to grounded-wye type transformers. This is tested on a Taipower system case which included 345KV, 161KV and 69KV feeders, network transformers, 34 PV bus generators and 188 three-phase buses. Impending unbalance problems in Taipower system were located. When not too many delta-grounded wye type transformers are in the

  12. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  13. Power delivery system

    SciTech Connect

    Moroto, S.; Sakakibara, S.

    1987-06-16

    This patent describes a power delivery system for connecting a transmission to an output shaft of an engine, the transmission including a dog clutch for establishing a power transmission route by the engagement of the dog clutch, the power delivery system comprising; a clutch for disconnecting the engagement between an output member of the fluid coupling and the output shaft when the dog clutch is operated in order to switch between an on-state and an off-state. The clutch includes a clutch plate case in the form of a hollow cylinder which is connected to the turbine shell. A clutch disk wheel connected to the output shaft. A first set of clutch plates supports the clutch plate case, and a second set of clutch plates supports the clutch disk wheel. The first and second sets of clutch plates are positioned within the case adjacent the radially inward periphery of the fluid coupling; the clutch is engaged when the first and second sets of clutch plates are selectively pressed; an oil pump for supplying oil into the fluid coupling case; and the oil pump positioned within the case adjacent the radially inward periphery of the clutch.

  14. Fuzzy system applications for short-term electric load forecasting

    NASA Astrophysics Data System (ADS)

    Al-Kandari, Ahmad Mohammad

    Load forecasting is an important function in economic power generation, allocation between plants (Unit Commitment Scheduling), maintenance scheduling, and for system security applications such as peak shaving by power interchange with interconnected utilities. In this thesis the problem of fuzzy short term load forecasting is formulated and solved. The thesis starts with a discussion of conventional algorithms used in short-term load forecasting. These algorithms are based on least error squares and least absolute value. The theory behind each algorithm is explained. Three different models are developed and tested in the first part of the thesis. The first model (A) is a regression model that takes into account the weather parameters in summer and winter seasons. The second model (B) is a harmonics based model, which does not account for weather parameters, but considers the parameters as a function of time. Model (B) can be used where variations in weather parameters are not available. Finally, model (C) is created as a hybrid combination of models A and B. The parameters of the three models are estimated using the two static estimation algorithms and are used later to predict the load for twenty-four hours ahead. The results obtained are discussed and conclusions are drawn for these models. In the second part of the thesis new fuzzy models are developed for crisp load power with fuzzy load parameters and for fuzzy load power with fuzzy load parameters. Three fuzzy models (A), (B) and (C) are developed. The fuzzy load model (A) is a fuzzy linear regression model for summer and winter seasons. Model (B) is a harmonic fuzzy model, which does not account for weather parameters. Finally fuzzy load model (C) is a hybrid combination of fuzzy load models (A) and (B). Estimating the fuzzy parameters for the three models turns out to be one of linear optimization. The fuzzy parameters are obtained for the three models. These parameters are used to predict the load as a

  15. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    NASA Technical Reports Server (NTRS)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  16. Power Management and Distribution System Developed for Thermionic Power Converters

    NASA Technical Reports Server (NTRS)

    Baez, Anastacio N.

    1998-01-01

    A spacecraft solar, bimodal system combines propulsion and power generation into a single integrated system. An Integrated Solar Upper Stage (ISUS) provides orbital transfer capabilities, power generation for payloads, and onboard propulsion to the spacecraft. A key benefit of a bimodal system is a greater payload-to-spacecraft mass ratio resulting in lower launch vehicle requirements. Scaling down to smaller launch vehicles increases space access by reducing overall mission cost. NASA has joined efforts with the Air Force Phillips Laboratory to develop enabling technologies for such a system. The NASA/Air Force bimodal concept uses solar concentrators to focus energy into an integrated power plant. This power plant consists of a graphite core that stores thermal energy within a cavity. An array of thermionic converters encircles the graphite cavity and provides electrical energy conversion functions. During the power generation phase of the bimodal system, the thermionic converters are exposed to the heated cavity and convert the thermal energy to electricity. Near-term efforts of the ISUS bimodal program are focused on a ground demonstration of key technologies in order to proceed to a full space flight test. Thermionic power generation is one key technology of the bimodal concept. Thermionic power converters impose unique operating requirements upon a power management and distribution (PMAD) system design. Single thermionic converters supply large currents at very low voltages. Operating voltages can vary over a range of up to 3 to 1 as a function of operating temperature. Most spacecraft loads require regulated 28-volts direct-current (Vdc) power. A combination of series-connected converters and powerprocessing boosters is required to deliver power to the spacecraft's payloads at this level.

  17. Power control and management of the grid containing largescale wind power systems

    NASA Astrophysics Data System (ADS)

    Aula, Fadhil Toufick

    The ever increasing demand for electricity has driven many countries toward the installation of new generation facilities. However, concerns such as environmental pollution and global warming issues, clean energy sources, high costs associated with installation of new conventional power plants, and fossil fuels depletion have created many interests in finding alternatives to conventional fossil fuels for generating electricity. Wind energy is one of the most rapidly growing renewable power sources and wind power generations have been increasingly demanded as an alternative to the conventional fossil fuels. However, wind power fluctuates due to variation of wind speed. Therefore, large-scale integration of wind energy conversion systems is a threat to the stability and reliability of utility grids containing these systems. They disturb the balance between power generation and consumption, affect the quality of the electricity, and complicate load sharing and load distribution managing and planning. Overall, wind power systems do not help in providing any services such as operating and regulating reserves to the power grid. In order to resolve these issues, research has been conducted in utilizing weather forecasting data to improve the performance of the wind power system, reduce the influence of the fluctuations, and plan power management of the grid containing large-scale wind power systems which consist of doubly-fed induction generator based energy conversion system. The aims of this research, my dissertation, are to provide new methods for: smoothing the output power of the wind power systems and reducing the influence of their fluctuations, power managing and planning of a grid containing these systems and other conventional power plants, and providing a new structure of implementing of latest microprocessor technology for controlling and managing the operation of the wind power system. In this research, in order to reduce and smooth the fluctuations, two

  18. Nuclear power propulsion system for spacecraft

    NASA Astrophysics Data System (ADS)

    Koroteev, A. S.; Oshev, Yu. A.; Popov, S. A.; Karevsky, A. V.; Solodukhin, A. Ye.; Zakharenkov, L. E.; Semenkin, A. V.

    2015-12-01

    The proposed designs of high-power space tugs that utilize solar or nuclear energy to power an electric jet engine are reviewed. The conceptual design of a nuclear power propulsion system (NPPS) is described; its structural diagram, gas circuit, and electric diagram are discussed. The NPPS incorporates a nuclear reactor, a thermal-to-electric energy conversion system, a system for the conversion and distribution of electric energy, and an electric propulsion system. Two criterion parameters were chosen in the considered NPPS design: the temperature of gaseous working medium at the nuclear reactor outlet and the rotor speed of turboalternators. The maintenance of these parameters at a given level guarantees that the needed electric voltage is generated and allows for power mode control. The processes of startup/shutdown and increasing/reducing the power, the principles of distribution of electric energy over loads, and the probable emergencies for the proposed NPPS design are discussed.

  19. Agreement between the force platform method and the combined method measurements of power output during the loaded countermovement jump.

    PubMed

    Mundy, Peter D; Lake, Jason P; Carden, Patrick J C; Smith, Neal A; Lauder, Mike A

    2016-01-01

    There are two perceived criterion methods for measuring power output during the loaded countermovement jump (CMJ): the force platform method and the combined method (force platform + optoelectronic motion capture system). Therefore, the primary aim of the present study was to assess agreement between the force platform method and the combined method measurements of peak power and mean power output during the CMJ across a spectrum of loads. Forty resistance-trained team sport athletes performed maximal effort CMJ with additional loads of 0 (body mass only), 25, 50, 75 and 100% of body mass (BM). Bias was present for peak velocity, mean velocity, peak power and mean power at all loads investigated, and present for mean force up to 75% of BM. Peak velocity, mean velocity, peak power and mean power 95% ratio limits of agreement were clinically unacceptable at all loads investigated. The 95% ratio limits of agreement were widest at 0% of BM and decreased linearly as load increased. Therefore, the force platform method and the combined method cannot be used interchangeably for measuring power output during the loaded CMJ. As such, if power output is to be meaningfully investigated, a standardised method must be adopted.

  20. Dielectric Loaded Broadband Gyro-TWT System

    DTIC Science & Technology

    1993-12-31

    A•wov•] f~ •ubic re] ease ;a AD-A277 889 -4 LLV t Final Report 01 Jan 92 - 31 Dec 93 DIELECTRIC LOADED BROADBAND GYRO- TWT SYSTEM Professor N. C...Loaded Broadband Gyro- TWT System" CONTRACT / GRANT NO.: F49620-92-J-O 175 CONTRACT / GRANT VALUE: $89,816 Acce’son For CONTRACT / GRANT PERIOD OF... Broadband Dielectric-Loaded Gyro- TWT Amplifier," submitted for publication to Physics Review Letters, October, 1993. A. Gover, F.V. Hartemann, G.P. Le

  1. Power Control System for the AGIILE Satellite

    NASA Astrophysics Data System (ADS)

    Ebale, G.; Lamantia, A.; La Bella, M.

    2005-05-01

    This paper describes the operation and design of the AGILE (Astrorivelatore Gamma a Immagini Leggero) power control system PEB (Power Electronic Box); the satellite is based on the MITA bus (Minisatellite Italiano a Tecnologia Avanzata). The main design drivers are: • Efficiency of the system due to size limitation of the solar array and battery • Mass • Redundancy management. The unit provides an unregulated bus of 22.5÷35VDC and manages an average power to the loads of about 210W, with peak values up to 350W.

  2. Solar energy thermally powered electrical generating system

    NASA Technical Reports Server (NTRS)

    Owens, William R. (Inventor)

    1989-01-01

    A thermally powered electrical generating system for use in a space vehicle is disclosed. The rate of storage in a thermal energy storage medium is controlled by varying the rate of generation and dissipation of electrical energy in a thermally powered electrical generating system which is powered from heat stored in the thermal energy storage medium without exceeding a maximum quantity of heat. A control system (10) varies the rate at which electrical energy is generated by the electrical generating system and the rate at which electrical energy is consumed by a variable parasitic electrical load to cause storage of an amount of thermal energy in the thermal energy storage system at the end of a period of insolation which is sufficient to satisfy the scheduled demand for electrical power to be generated during the next period of eclipse. The control system is based upon Kalman filter theory.

  3. Matlab for Forecasting of Electric Power Load Based on BP Neural Network

    NASA Astrophysics Data System (ADS)

    Wang, Xi-Ping; Shi, Ming-Xi

    Modeling and predicting electricity consumption play a vital role both in developed and developing countries for policy makers and related organizations. Improve load forecasting technology level is not only beneficial to plan power management and make reasonable construction plan, but also good for saving energy and reducing power cost, and then, it can improve the economic benefits and social benefit for power system. BP neural network is one of the most widely used neural networks and it has many advantages in the power load forecasting. Matlab has become the best technology application software which has been internationally recognized, the software has many characteristics, such as data visualization function and neural network toolbox, for these, it is the essential software when we do some research on neural network.

  4. Solar Dynamic Power System Fault Diagnosis

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Dias, Lakshman G.

    1996-01-01

    The objective of this research is to conduct various fault simulation studies for diagnosing the type and location of faults in the power distribution system. Different types of faults are simulated at different locations within the distribution system and the faulted waveforms are monitored at measurable nodes such as at the output of the DDCU's. These fault signatures are processed using feature extractors such as FFT and wavelet transforms. The extracted features are fed to a clustering based neural network for training and subsequent testing using previously unseen data. Different load models consisting of constant impedance and constant power are used for the loads. Open circuit faults and short circuit faults are studied. It is concluded from present studies that using features extracted from wavelet transforms give better success rates during ANN testing. The trained ANN's are capable of diagnosing fault types and approximate locations in the solar dynamic power distribution system.

  5. Power Systems Development Facility

    SciTech Connect

    2003-07-01

    This report discusses Test Campaign TC12 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (SW) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). While operating as a gasifier, either air or oxygen can be used as the oxidant. Test run TC12 began on May 16, 2003, with the startup of the main air compressor and the lighting of the gasifier start-up burner. The Transport Gasifier operated until May 24, 2003, when a scheduled outage occurred to allow maintenance crews to install the fuel cell test unit and modify the gas clean-up system. On June 18, 2003, the test run resumed when operations relit the start-up burner, and testing continued until the scheduled end of the run on July 14, 2003. TC12 had a total of 733 hours using Powder River Basin (PRB) subbituminous coal. Over the course of the entire test run, gasifier temperatures varied between 1,675 and 1,850 F at pressures from 130 to 210 psig.

  6. Space Station power system selection

    NASA Technical Reports Server (NTRS)

    Rice, R. R.

    1986-01-01

    The Space Station power system selection process is described with attention given to management organization and technical considerations. A hybrid power system was chosen because of the large life cycle cost savings. The power management and distribution system that was chosen was the 400 Hz system.

  7. High voltage solar cell power generating system

    NASA Technical Reports Server (NTRS)

    Levy, E., Jr.; Opjorden, R. W.; Hoffman, A. C.

    1974-01-01

    A laboratory solar power system regulated by on-panel switches has been delivered for operating high power (3 kW), high voltage (15,000 volt) loads (communication tubes, ion thrusters). The modular system consists of 26 solar arrays, each with an integral light source and cooling system. A typical array contains 2,560 series-connected cells. Each light source consists of twenty 500-watt tungsten iodide lamps providing plus or minus 5 percent uniformity at one solar constant. An array temperature of less than 40 C is achieved using an infrared filter, a water-cooled plate, a vacuum hold-down system, and air flushing.

  8. Power System Harmonic Elimination to Improve Power Quality

    NASA Astrophysics Data System (ADS)

    Chandrasekaran, K.; Ramachandaramurthy, V. K.

    2015-06-01

    An improvised RLC interface filter for a Dynamic Voltage Restorer (DVR) is proposed. The RLC filter is connected in the front end between the IGBT based Voltage Source Inverter (VSI) and the injection transformer and is able to eliminate voltage harmonics in the system and also switching harmonics generated from VSI. The voltage at the sensitive load end is pure sinusoidal. In this method, the DVR produced Pulse Width Modulation (PWM) voltage with voltage harmonic canceling the voltage harmonic generated from the supply main. The VSI handles harmonic power. The low order switching harmonics generated by the IGBT based VSI is suppressed. The DVR has greater voltage injection capability. Good dynamic and transient results recorded and Total Harmonic Distortion (THD) at the sensitive load end is minimized. The voltage at the sensitive load is sinusoidal and at 1.0 pu. PSCAD/EMTDC is used to validate the performance of the interface filter and the DVR. Simulated results are presented.

  9. Simulation of a Wireless Power Transfer System for Electric Vehicles with Power Factor Correction

    SciTech Connect

    Pickelsimer, Michael C; Tolbert, Leon M; Ozpineci, Burak; Miller, John M

    2012-01-01

    Wireless power transfer has been a popular topic of recent research. Most research has been done to address the limitations of coil-to-coil efficiency. However, little has been done to address the problem associated with the low input power factor with which the systems operate. This paper details the steps taken to analyze a wireless power transfer system from the view of the power grid under a variety of loading conditions with and without power factor correction.

  10. Plug and Process Loads Capacity and Power Requirements Analysis

    SciTech Connect

    Sheppy, M.; Gentile-Polese, L.

    2014-09-01

    This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

  11. Hybrid Photovoltaic-Hydrogen Power Conditioning System

    NASA Astrophysics Data System (ADS)

    Garrigos, A.; Blanes, J. M.; Carrasco, J. A.; Maset, E.; Ejea, J. B.; Ferreres, A.; Sanchis, E.

    2011-10-01

    This paper explores a power conditioning unit for photovoltaic/hydrogen based energy systems. Similar power conversion techniques, compared to traditional space power systems, are applied. An S4R regulator is devised with an unregulated battery bus as primary output and a secondary path to feed and electrolyser. A modular fuel cell converter completes the system and it operates when photovoltaic energy is not available or load demand exceeds solar power, i. e. like a traditional BDR. An ancillary battery keeps the unregulated bus voltage distributed in the system and it also aids the fuel cell during transients or start-up due to its limited speed. A 1kW breadboard has been designed and implemented to corroborate the proposed system.

  12. Faculty Teaching Loads in the UNC System

    ERIC Educational Resources Information Center

    Schalin, Jay

    2014-01-01

    This paper explores the teaching loads of faculty in the University of North Carolina (UNC) system. Salaries for faculty members are the single largest cost of higher education in the UNC system, accounting for approximately half of expenditures. The system's funding formula for its 16 college campuses is largely dependent upon the number of…

  13. A high-power switch-mode dc power supply for dynamic loads

    SciTech Connect

    Shimer, D.W.; Lange, A.C.; Bombay, J.N.

    1994-06-23

    High-voltage dc power supplies are often required to operate with highly dynamic loads, such as arcs. A switch-mode dc power supply can offer significant advantages over conventional thyristor-based dc power supplies under such conditions. It can quickly turn off the supply to extinguish the arc, and it can quickly recover after the arc. It has a relatively small output filter capacitance, which results in small stored energy available to the arc. A 400-kW, 50-kV switch-mode dc power supply for an electron-beam gun that exploits these advantages was designed and tested. It uses four 100-kW, current-source-type dc-dc converters with inputs in parallel and outputs in series. The dc-dc converters operate at 20 kHz in the voltage regulator part and 10 kHz in the inverter, transformer, and output rectifier part of the circuit. Insulated gate bipolar transistors (IGBTs) are used as the power switches. Special techniques are used to protect the power supply and load against arcs and hard shorts. The power supply has an efficiency of 93%, an output voltage ripple of 1%, and fast dynamic response. In addition, it is nearly one-third the size of conventional power supplies.

  14. Power Systems Development Facility

    SciTech Connect

    Southern Company Services

    2004-04-30

    This report discusses Test Campaign TC15 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Power Generation, Inc. (SPG) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or gasifier using a particulate control device (PCD). While operating as a gasifier, either air or oxygen can be used as the oxidant. Test run TC15 began on April 19, 2004, with the startup of the main air compressor and the lighting of the gasifier startup burner. The Transport Gasifier was shutdown on April 29, 2004, accumulating 200 hours of operation using Powder River Basin (PRB) subbituminous coal. About 91 hours of the test run occurred during oxygen-blown operations. Another 6 hours of the test run was in enriched-air mode. The remainder of the test run, approximately 103 hours, took place during air-blown operations. The highest operating temperature in the gasifier mixing zone mostly varied from 1,800 to 1,850 F. The gasifier exit pressure ran between 200 and 230 psig during air-blown operations and between 110 and 150 psig in oxygen-enhanced air operations.

  15. Power training using pneumatic machines vs. plate-loaded machines to improve muscle power in older adults.

    PubMed

    Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F

    2017-11-01

    Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate-loaded

  16. Load control system. [for space shuttle external tank ground tests

    NASA Technical Reports Server (NTRS)

    Grosse, J. C.

    1977-01-01

    The load control system developed for the shuttle external structural tests is described. The system consists of a load programming/display module, and a load control module along with the following hydraulic system components: servo valves, dump valves, hydraulic system components, and servo valve manifold blocks. One load programming/display subsystem can support multiple load control subsystem modules.

  17. Power factor control system for AC induction motors

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1977-01-01

    A power factor control system for use with ac induction motors was designed which samples lines voltage and current through the motor and decreases power input to the motor proportional to the detected phase displacement between current and voltage. This system provides, less power to the motor, as it is less loaded.

  18. Smart Power Supply for Battery-Powered Systems

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Greer, Lawrence; Prokop, Norman F.; Flatico, Joseph M.

    2010-01-01

    A power supply for battery-powered systems has been designed with an embedded controller that is capable of monitoring and maintaining batteries, charging hardware, while maintaining output power. The power supply is primarily designed for rovers and other remote science and engineering vehicles, but it can be used in any battery alone, or battery and charging source applications. The supply can function autonomously, or can be connected to a host processor through a serial communications link. It can be programmed a priori or on the fly to return current and voltage readings to a host. It has two output power busses: a constant 24-V direct current nominal bus, and a programmable bus for output from approximately 24 up to approximately 50 V. The programmable bus voltage level, and its output power limit, can be changed on the fly as well. The power supply also offers options to reduce the programmable bus to 24 V when the set power limit is reached, limiting output power in the case of a system fault detected in the system. The smart power supply is based on an embedded 8051-type single-chip microcontroller. This choice was made in that a credible progression to flight (radiation hard, high reliability) can be assumed as many 8051 processors or gate arrays capable of accepting 8051-type core presently exist and will continue to do so for some time. To solve the problem of centralized control, this innovation moves an embedded microcontroller to the power supply and assigns it the task of overseeing the operation and charging of the power supply assets. This embedded processor is connected to the application central processor via a serial data link such that the central processor can request updates of various parameters within the supply, such as battery current, bus voltage, remaining power in battery estimations, etc. This supply has a direct connection to the battery bus for common (quiescent) power application. Because components from multiple vendors may have

  19. POWER SYSTEMS DEVELOPMENT FACILITY

    SciTech Connect

    Unknown

    2002-11-01

    This report discusses test campaign GCT4 of the Kellogg Brown & Root, Inc. (KBR) transport reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The transport reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using one of two possible particulate control devices (PCDs). The transport reactor was operated as a pressurized gasifier during GCT4. GCT4 was planned as a 250-hour test run to continue characterization of the transport reactor using a blend of several Powder River Basin (PRB) coals and Bucyrus limestone from Ohio. The primary test objectives were: Operational Stability--Characterize reactor loop and PCD operations with short-term tests by varying coal-feed rate, air/coal ratio, riser velocity, solids-circulation rate, system pressure, and air distribution. Secondary objectives included the following: Reactor Operations--Study the devolatilization and tar cracking effects from transient conditions during transition from start-up burner to coal. Evaluate the effect of process operations on heat release, heat transfer, and accelerated fuel particle heat-up rates. Study the effect of changes in reactor conditions on transient temperature profiles, pressure balance, and product gas composition. Effects of Reactor Conditions on Synthesis Gas Composition--Evaluate the effect of air distribution, steam/coal ratio, solids-circulation rate, and reactor temperature on CO/CO{sub 2} ratio, synthesis gas Lower Heating Value (LHV), carbon conversion, and cold and hot gas efficiencies. Research Triangle Institute (RTI) Direct Sulfur Recovery Process (DSRP) Testing--Provide syngas in support of the DSRP commissioning. Loop Seal Operations--Optimize loop seal operations and investigate increases to previously achieved maximum solids-circulation rate.

  20. Power variation during the functioning of nonlinear load

    NASA Astrophysics Data System (ADS)

    Panoiu, C.; Rob, R.; Panoiu, M.

    2016-02-01

    Present paper studies the variation of active, reactive, distorted and apparent powers measured during the functioning of an electro thermal installation with electromagnetic induction. In order to analyze these electrical parameters, measurement sets were accomplished using two methods. The first method is based on using a power quality analyzer and the second method consists in using a data acquisition system that contains an adapting interface and a data acquisition board connected to a computer.

  1. Electronic load as part of the test complex of the power processing unit of electric and plasma propulsion

    NASA Astrophysics Data System (ADS)

    Chubov, S. V.; Soldatov, A. I.

    2017-02-01

    This article provides the advantages and technical solutions for the use of electronic loads as part of a testing complex of power and management systems of electric and plasma propulsion of three types. The paper shows the parameters that were applied to select the electronic loads and describes their functionality.

  2. Solar thermal power system

    DOEpatents

    Bennett, Charles L.

    2010-06-15

    A solar thermal power generator includes an inclined elongated boiler tube positioned in the focus of a solar concentrator for generating steam from water. The boiler tube is connected at one end to receive water from a pressure vessel as well as connected at an opposite end to return steam back to the vessel in a fluidic circuit arrangement that stores energy in the form of heated water in the pressure vessel. An expander, condenser, and reservoir are also connected in series to respectively produce work using the steam passed either directly (above a water line in the vessel) or indirectly (below a water line in the vessel) through the pressure vessel, condense the expanded steam, and collect the condensed water. The reservoir also supplies the collected water back to the pressure vessel at the end of a diurnal cycle when the vessel is sufficiently depressurized, so that the system is reset to repeat the cycle the following day. The circuital arrangement of the boiler tube and the pressure vessel operates to dampen flow instabilities in the boiler tube, damp out the effects of solar transients, and provide thermal energy storage which enables time shifting of power generation to better align with the higher demand for energy during peak energy usage periods.

  3. Fuel cell stack compressive loading system

    DOEpatents

    Fahle, Ronald W.; Reiser, Carl A.

    1982-01-01

    A fuel cell module comprising a stack of fuel cells with reactant gas manifolds sealed against the external surfaces of the stack includes a constraint system for providing a compressive load on the stack wherein the constraint system maintains the stack at a constant height (after thermal expansion) and allows the compressive load to decrease with time as a result of the creep characteristics of the stack. Relative motion between the manifold sealing edges and the stack surface is virtually eliminated by this constraint system; however it can only be used with a stack having considerable resiliency and appropriate thermal expansion and creep characteristics.

  4. Design of advanced fossil-fuel systems (DAFFS): a study of three developing technologies for coal-fired, base-load electric power generation. Integrated coal-gasification/combined power plant with BGC/Lurgi gasification process

    SciTech Connect

    Not Available

    1983-06-01

    The objectives of this report are to present the facility description, plant layouts and additional information which define the conceptual engineering design, and performance and cost estimates for the BGC/Lurgi Integrated Gasification Combined Cycle (IGCC) power plant. Following the introductory comments, the results of the British Gas Corporation (BGC)/Lurgi IGCC power plant study are summarized in Section 2. In Secion 3, a description of plant systems and facilities is provided. Section 4 includes pertinent performance information and assessments of availability, natural resource requirements and environmental impact. Estimates of capital costs, operating and maintenance costs and cost of electricity are presented in Section 5. A Bechtel Group Inc. (BGI) assessment and comments on the designs provided by Burns and Roe-Humphreys and Glasgow Synthetic Fuels, Inc. (BRHG) are included in Section 6. The design and cost estimate reports which were prepared by BRHG for those items within their scope of responsibility are included as Appendices A and B, respectively. Apendix C is an equipment list for items within the BGI scope. The design and cost estimate classifications chart referenced in Section 5 is included as Appendix D. 8 references, 18 figures, 5 tables.

  5. Satellite Power System (SPS)

    NASA Technical Reports Server (NTRS)

    Edler, H. G.

    1978-01-01

    Potential organizational options for a solar power satellite system (SPS) were investigated. Selection and evaluation criteria were determined to include timeliness, reliability, and adequacy to contribute meaningfully to the U.S. supply; political feasibility (both national and international); and cost effectiveness (including environmental and other external costs). Based on these criteria, four organizational alternatives appeared to offer reasonable promise as potential options for SPS. A large number of key issues emerged as being factors which would influence the final selection process. Among these issues were a variety having to do with international law, international institutions, environmental controls, economics, operational flexibility, congressional policies, commercial-vs-governmental ownership, national dedication, and national and operational stategic issues.

  6. Intelligent systems for strategic power infrastructure defense

    NASA Astrophysics Data System (ADS)

    Jung, Ju-Hwan

    A fault or disturbance in a power system can be severe due to the sources of vulnerability such as human errors, protection and control system failures, a failure of communication networks to deliver critical control signals, and market and load uncertainties. There have been several catastrophic failures resulting from disturbances involving the sources of vulnerability while power systems are designed to withstand disturbances or faults. To avoid catastrophic failures or minimize the impact of a disturbance(s), the state of the power system has to be analyzed correctly and preventive or corrective self-healing control actions have to be deployed. This dissertation addresses two aspects of power systems: Defense system and diagnosis, both concerned with the power system analysis and operation during events involving faults or disturbances. This study is intended to develop a defense system that is able to assess power system vulnerability and to perform self-healing control actions based on the system-wide analysis. In order to meet the requirements of the system-wide analysis, the defense system is designed with multi-agent system technologies. Since power systems are dynamic and uncertain the self-healing control actions need to be adaptive. This study applies the reinforcement learning technique to provide a theoretical basis for adaptation. One of the important issues in adaptation is the convergence of the learning algorithm. An appropriate convergence criterion is derived and an application with a load-shedding scheme is demonstrated in this study. This dissertation also demonstrates the feasibility of the defense system and self-healing control actions through multi-agent system technologies. The other subject of this research is to investigate the methodology for on-line fault diagnosis using the information from Sequence-of-Events Recorders (SER). The proposed multiple-hypothesis analysis generates one or more hypothetical fault scenarios to interpret the

  7. Electrical power systems (Jamaica). Electrical power systems, July 1992. Export trade information

    SciTech Connect

    Not Available

    1992-07-01

    The United States presently supplies 70% of Jamaica's demand for Electrical Power Systems. Market demand is not limited to the requirements of the National Power Company. There is domestic demand created by the need to have backup or stand-by facilities during load shedding or power outages. Ongoing refurbishing programs and the ultimate need to increase the capacity of the Public Service Company will facilitate an ongoing demand for power systems. The market is very steady and will gain momentum lasting well beyond 1993.

  8. Power output in vertical jumps: does optimum loading depend on activity profiles?

    PubMed

    Pazin, Nemanja; Berjan, Bobana; Nedeljkovic, Aleksandar; Markovic, Goran; Jaric, Slobodan

    2013-03-01

    The previously proposed maximum dynamic output hypothesis (MDO: i.e. the optimum load for maximizing the power output during jumping is one's own body) was tested on individuals of various activity profiles. Forty males (10 strength-trained athletes, 10 speed-trained athletes, 10 physically active non-athletes, and 10 sedentary individuals) performed different vertical jumps on a force plate while a pulley system was used to either reduce or increase the subject's body weight by 10-30 %. As expected, an increase in external loading resulted in a significant increase (p < 0.001) in force output and a concomitant decrease of peak jumping velocity in all groups of participants. The main finding, however, was that all groups revealed the maximum peak and mean power output at approximately the subjects' own body weight although their weight represented prominently different percentage of their maximum dynamic strength. While a significant (p < 0.05), albeit moderate, 'group × load' interaction in one jump was observed for the peak power output, the individual optimum load for maximizing the power output number did not differ among the groups. Although apparently further research on various types of movements is needed, the present results provide, so far, the strongest support of the MDO hypothesis.

  9. Spacecraft power system architecture to mitigate spacecraft charging effects

    NASA Technical Reports Server (NTRS)

    Manner, David B. (Inventor)

    1997-01-01

    A power system architecture for a spacecraft and a method of a power supply for a spacecraft are presented which take advantage of the reduced plasma interaction associated with positive ground high voltage photovoltaic arrays and provide a negative ground power supply for electrical loads of the spacecraft. They efficiently convert and regulate power to the load bus and reduce power system mass and complexity. The system and method ground the positive terminal of the solar arrays to the spacecraft hull, and using a power converter to invert the electric sign, permit a negative ground for the electrical distribution bus and electrical components. A number of variations including a load management system and a battery management system having charging and recharging devices are presented.

  10. Anticipatory regulation of complex power systems

    NASA Astrophysics Data System (ADS)

    Fieno, Thomas Edward

    Electric generation control is performed in a distributed manner to supply power to geographically defined control areas. The goal of generation control is to keep the inadvertent flow of power across a control area's boundary as small as possible. If a difference exists between the power supplied and the power demanded in a control area, the load deficit or surplus would be either borrowed from or stored as the kinetic energy in rotating machines on the grid. This thesis addresses the challenge of matching the power demand of a local area grid with the power delivered by a coal-fired power plant. An anticipatory controller for a model power plant is presented to prescribe the power output into the grid. The control system forecasts what the future demand of the power customers in a control area is likely to be and modifies the fuel input to the power generation facility in order to match the predicted demand. A neural network was found to be an adaptable and robust prediction mechanism for the highly nonlinear data found in the power consumption patterns in a residential area of the Commonwealth Edison grid. The corresponding control schedule of the power plant was tuned to match the anticipated demand using an iterative neural network approach. The use of neural networks and an iterative scheme allows the controller design in this research to be applied to a broad range of control problems. The control methodology presented takes into account limits in the magnitude and rate of control actions. Simulations show that this implementation of anticipatory control of electric power demand is effective and especially well suited to dynamic systems that include a dead time or control limitations. The response of the anticipatory neural network control system was shown to be more energy efficient than feedback control for a typical thermal power regulation facility and to have a much smoother, reduced control effort.

  11. Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads

    SciTech Connect

    Olama, Mohammed M; Sharma, Isha; Kuruganti, Teja; Fugate, David L

    2017-01-01

    In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis of building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.

  12. High power ac/dc variable R dynamic electrical load simulator

    NASA Technical Reports Server (NTRS)

    Joncas, K. P.

    1974-01-01

    A study program was undertaken to investigate various concepts and techniques for identifying and simulating both the steady-state and dynamic characteristics of electrical loads for use during integrated system test and evaluation. The development of hardware capable of providing the simulation capability is discussed. A general purpose simulator was developed with the capability of realizing a variety of models where element values were discretely variable. The different models, each corresponding to real spacecraft equipment, are set up manually for each case by suitable switching and patching. The models are capable of duplicating the dynamic and steady-state response of real loads at full power.

  13. Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

    SciTech Connect

    Sheppy, M.; Torcellini, P.; Gentile-Polese, L.

    2014-08-01

    Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

  14. Power Management Integrated Circuit for Indoor Photovoltaic Energy Harvesting System

    NASA Astrophysics Data System (ADS)

    Jain, Vipul

    In today's world, power dissipation is a main concern for battery operated mobile devices. Key design decisions are being governed by power rather than area/delay because power requirements are growing more stringent every year. Hence, a hybrid power management system is proposed, which uses both a solar panel to harvest energy from indoor lighting and a battery to power the load. The system tracks the maximum power point of the solar panel and regulates the battery and microcontroller output load voltages through the use of an on-chip switched-capacitor DC-DC converter. System performance is verified through simulation at the 180nm technology node and is made to be integrated on-chip with 0.25 second startup time, 79% efficiency, --8/+14% ripple on the load, an average 1micro A of quiescent current (3.7micro W of power) and total on-chip area of 1.8mm2 .

  15. New Paradigm of Power System Planning under Competitive Environment

    NASA Astrophysics Data System (ADS)

    Mori, Hiroyuki

    This paper presents a new paradigm of power system planning under competitive environment. As the liberalization of power systems become more competitive, power systems are faced with new aspects that the conventional bundled power company has never encountered. The conventional power system planning methods do not match the requirements of competitive environment. In practice, the power system liberalization brings about new environment that puts emphasis on the profit maximization and the risk minimization. Thus, the problem formulation of power system planning should be reformulated to reflect the new aspects in power systems. As the tasks of power system planning, this paper outlines transmission network expansion planning, distribution network expansion planning, and unit commitment under competitive environment. In addition, new tasks such as very short-term load forecasting, electricity price forecasting, and wind power forecasting are described.

  16. Superconductivity for electric power systems: Program overview

    SciTech Connect

    Not Available

    1995-02-01

    Largely due to government and private industry partnerships, electric power applications based upon high-temperature superconductivity are now being designed and tested only seven years after the discovery of the high-temperature superconductors. These applications offer many benefits to the national electric system including: increased energy efficiency, reduced equipment size, reduced emissions, increased stability/reliability, deferred expansion, and flexible electricity dispatch/load management. All of these benefits have a common outcome: lower electricity costs and improved environmental quality. The U.S. Department of Energy (DOE) sponsors research and development through its Superconductivity Program for Electric Power Systems. This program will help develop the technology needed for U.S. industries to commercialize high-temperature superconductive electric power applications. DOE envisions that by 2010 the U.S. electric power systems equipment industry will regain a major share of the global market by offering superconducting products that outperform the competition.

  17. 40 CFR 86.129-80 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... power, test weight, and inertia weight class determination. (a) (b) Power absorption unit adjustment—light-duty trucks. (1) The power absorption unit shall be adjusted to reproduce road load power at 50... of the table. (c) Power absorption unit adjustment—light-duty vehicles. (1) The power absorption...

  18. Design of fluid-loaded piezoelectric transducers for acoustic power considerations

    NASA Astrophysics Data System (ADS)

    Grosh, Karl; Lin, Yuan; Nelli Silva, Emilio C.; Kikuchi, Noboru

    1998-07-01

    In this paper, a design methodology for enhancing the acoustic power radiated from fluid-loaded piezoelectric transducers at a particular operating frequency is developed. For many applications the operating frequency is fixed by the absorption of the material and the desired depth of penetration (e.g., therapeutic ultrasound). For therapeutic ultrasound and other industrial applications, the acoustic power is the critical figure of merit. The acoustic power radiated from the transducer system is computed from a finite element formulation of the coupled acoustic, elastic, piezoelectric equations of motion. The sensitivities of the acoustic power to two design variables: the length of the piezoelectric element and the thickness of the matching layer, are derived. Using these sensitivities, a novel design methodology in which remeshing is avoided is developed and the effectiveness of the method is studied. Results from the application of this framework for transducer design demonstrate the dramatic increase in radiated power possible from this two member design space.

  19. Hybrid electric vehicle power management system

    SciTech Connect

    Bissontz, Jay E.

    2015-08-25

    Level voltage levels/states of charge are maintained among a plurality of high voltage DC electrical storage devices/traction battery packs that are arrayed in series to support operation of a hybrid electric vehicle drive train. Each high voltage DC electrical storage device supports a high voltage power bus, to which at least one controllable load is connected, and at least a first lower voltage level electrical distribution system. The rate of power transfer from the high voltage DC electrical storage devices to the at least first lower voltage electrical distribution system is controlled by DC-DC converters.

  20. Power Transfer in Physical Systems.

    ERIC Educational Resources Information Center

    Kaeck, Jack A.

    1990-01-01

    Explores the power transfer using (1) a simple electric circuit consisting of a power source with internal resistance; (2) two different mechanical systems (gravity driven and constant force driven); (3) ecological examples; and (4) a linear motor. (YP)

  1. Power Transfer in Physical Systems.

    ERIC Educational Resources Information Center

    Kaeck, Jack A.

    1990-01-01

    Explores the power transfer using (1) a simple electric circuit consisting of a power source with internal resistance; (2) two different mechanical systems (gravity driven and constant force driven); (3) ecological examples; and (4) a linear motor. (YP)

  2. Power management circuits for self-powered systems based on micro-scale solar energy harvesting

    NASA Astrophysics Data System (ADS)

    Yoon, Eun-Jung; Yu, Chong-Gun

    2016-03-01

    In this paper, two types of power management circuits for self-powered systems based on micro-scale solar energy harvesting are proposed. First, if a solar cell outputs a very low voltage, less than 0.5 V, as in miniature solar cells or monolithic integrated solar cells, such that it cannot directly power the load, a voltage booster is employed to step up the solar cell's output voltage, and then a power management unit (PMU) delivers the boosted voltage to the load. Second, if the output voltage of a solar cell is enough to drive the load, the PMU directly supplies the load with solar energy. The proposed power management systems are designed and fabricated in a 0.18-μm complementary metal-oxide-semiconductor process, and their performances are compared and analysed through measurements.

  3. Ferrite Loaded Coils for Improved Wireless Power Transfer Efficiency

    DTIC Science & Technology

    2015-09-01

    Vehicles requires physical electrical contact between the vehicle and a docking station specifically designed to accommodate only one particular...hull size. Inductive power transfer using mutually coupled coils eliminates physical contact , which can lead to an electrical short in a seawater...INTENTIONALLY LEFT BLANK v ABSTRACT Recharging the battery system on Navy Autonomous Underwater Vehicles requires physical electrical contact

  4. Determination of appropriate DC voltage for switched mode power supply (SMPS) loads

    NASA Astrophysics Data System (ADS)

    Setiawan, Eko Adhi; Setiawan, Aiman; Purnomo, Andri; Djamal, Muchlishah Hadi

    2017-03-01

    Nowadays, most of modern and efficient household electronic devices operated based on Switched Mode Power Supply (SMPS) technology which convert AC voltage from the grid to DC voltage. Based on theory and experiment, SMPS loads could be supplied by DC voltage. However, the DC voltage rating to energize electronic home appliances is not standardized yet. This paper proposed certain method to determine appropriate DC voltage, and investigated comparison of SMPS power consumption which is supplied from AC and DC voltage. To determine the appropriate DC voltage, lux value of several lamps which have same specification energized by using AC voltage and the results is using as reference. Then, the lamps were supplied by various DC voltage to obtain the trends of the lux value to the applied DC voltage. After that, by using the trends and the reference lux value, the appropriate DC voltage can be determined. Furthermore, the power consumption on home appliances such as mobile phone, laptop and personal computer by using AC voltage and the appropriate DC voltage were conducted. The results show that the total power consumption of AC system is higher than DC system. The total power (apparent power) consumed by the lamp, mobile phone and personal computer which operated in 220 VAC were 6.93 VA, 34.31 VA and 105.85 VA respectively. On the other hand, under 277 VDC the load consumption were 5.83 W, 19.11 W and 74.46 W respectively.

  5. Impurity levels and power loading in the PDX tokamak with high power neutral beam injection

    SciTech Connect

    Fonck, R.J.; Bell, M.; Bol, K.

    1982-10-01

    The PDX tokamak provides an experimental facility for the direct comparison of various impurity control techniques under reactor-like conditions. Four neutral beam lines can inject up to 6 MW for 300 ms. Carbon rail limiter discharges have been used to test the effectiveness of perpendicular injection, but non-disruptive full power operation for > 100 ms is difficult without extensive conditioning. Initial tests of a toroidal bumper limiter indicate reduced power loading and roughly similar impurity levels compared to the carbon rail limiter discharges. Poloidal divertor discharges with up to 5 MW of injected power are cleaner than similar circular discharges, and the power is deposited in a remote divertor chamber. High density divertor operation indicates a reduction of impurity flow velocity in the divertor and enhanced recycling in the divertor region during neutral injection.

  6. Compact X-band high power load using magnetic stainless steel

    SciTech Connect

    Tantawi, S.G. |; Vlieks, A.E.

    1995-05-01

    We present design and experimental results of a high power X-band load. The load is formed as a disk-loaded waveguide structure using lossy, Type 430 stainless steel. The design parameters have been optimized using the recently developed mode-matching code MLEGO. The load has been designed for compactness while maintaining a band width greater than 300 MHz.

  7. Control of an afterburner in a diesel fuel cell power unit under variable load

    NASA Astrophysics Data System (ADS)

    Dolanc, Gregor; Pregelj, Boštjan; Petrovčič, Janko; Samsun, Remzi Can

    2017-01-01

    In this paper, the control system for a catalytic afterburner in a diesel fuel cell auxiliary power unit is presented. The catalytic afterburner is used to burn the non-utilised hydrogen and other possible combustible components of the fuel cell anode off-gas. To increase the energy efficiency of the auxiliary power unit, the thermal energy released in the catalytic afterburner is utilised to generate the steam for the fuel processor. For optimal operation of the power unit in all modes of operation including load change, stable steam generation is required and overall energy balance must be kept within design range. To achieve this, the reaction temperature of the catalytic afterburner must be stable in all modes of operation. Therefore, we propose the afterburner temperature control based on mass and thermal balances. Finally, we demonstrate the control system using the existing prototype of the diesel fuel cell auxiliary power unit.

  8. Power System Control Study. Phase I. Integrated Control Techniques. Phase II. Detail Design and System Modeling.

    DTIC Science & Technology

    1981-03-01

    reliable and fault tolerant system. The advanced control technologies integrated include:electric engine start, automatic load manage- ment...Generation System Study .............................. 104 5.2 Reliability Assessment of Power System .................... 119 5.3 EMUX Processor...132 30 Best Main Power System Configuration Based on Reliability Assessment ..................................... 133 31 Main and Emergency Power

  9. Analysis of Mesh Distribution Systems Considering Load Models and Load Growth Impact with Loops on System Performance

    NASA Astrophysics Data System (ADS)

    Kumar Sharma, A.; Murty, V. V. S. N.

    2014-12-01

    The distribution system is the final link between bulk power system and consumer end. A distinctive load flow solution method is used for analysis of the load flow of radial and weakly meshed network based on Kirchhoff's Current Law (KCL) and KVL. This method has excellent convergence characteristics for both radial as well as weakly meshed structure and is based on bus injection to branch current and branch-current to bus-voltage matrix. The main contribution of the paper is: (i) an analysis has been carried out for a weekly mesh network considering number of loops addition and its impact on the losses, kW and kVAr requirements from a system, and voltage profile, (ii) different load models, realistic ZIP load model and load growth impact on losses, voltage profile, kVA and kVAr requirements, (iii) impact of addition of loops on losses, voltage profile, kVA and kVAr requirements from substation, and (iv) comparison of system performance with radial distribution system. Voltage stability is a major concern in planning and operation of power systems. This paper also includes identifying the closeness critical bus which is the most sensitive to the voltage collapse in radial distribution networks. Node having minimum value of voltage stability index is the most sensitive node. Voltage stability index values are computed for meshed network with number of loops added in the system. The results have been obtained for IEEE 33 and 69 bus test system. The results have also been obtained for radial distribution system for comparison.

  10. Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems

    SciTech Connect

    Peng, Fang Zheng; Lai, Jih-Sheng

    1996-10-01

    A generalized theory of instantaneous reactive power for three-phase power systems is proposed in this paper. This theory gives a generalized definition of instantaneous reactive power, which is valid for sinusoidal or nonsinusoidal, balanced or unbalanced, three- phase power systems with or without zero-sequence currents and/or voltages. The properties and physical meanings of the newly defined instantaneous reactive power are discussed in detail. With this new reactive power theory, it is very easy to calculate and decompose all components, such as fundamental active/reactive power and current, harmonic current, etc. Reactive power and/or harmonic compensation systems for a three-phase distorted power system with and without zero-sequence components in the source voltage and/or load current are then used as examples to demonstrate the measurement, decomposition, and compensation of reactive power and harmonics.

  11. Transport aircraft loading and balancing system: Using a CLIPS expert system for military aircraft load planning

    NASA Technical Reports Server (NTRS)

    Richardson, J.; Labbe, M.; Belala, Y.; Leduc, Vincent

    1994-01-01

    The requirement for improving aircraft utilization and responsiveness in airlift operations has been recognized for quite some time by the Canadian Forces. To date, the utilization of scarce airlift resources has been planned mainly through the employment of manpower-intensive manual methods in combination with the expertise of highly qualified personnel. In this paper, we address the problem of facilitating the load planning process for military aircraft cargo planes through the development of a computer-based system. We introduce TALBAS (Transport Aircraft Loading and BAlancing System), a knowledge-based system designed to assist personnel involved in preparing valid load plans for the C130 Hercules aircraft. The main features of this system which are accessible through a convivial graphical user interface, consists of the automatic generation of valid cargo arrangements given a list of items to be transported, the user-definition of load plans and the automatic validation of such load plans.

  12. Grey prediction model of power load based on exponential smoothing improvement

    NASA Astrophysics Data System (ADS)

    Wu, Di

    2017-08-01

    Grey system theory has the advantages of needing little sample data and calculating no characteristic quantity; it is widely applied in power load prediction; but it has certain limitation the larger the data discretization degree is, the larger the gray scale is and the larger the influence on prediction precision is. The paper improves original data of grey prediction by exponential smoothing to reduce data fluctuation and improve prediction precision.

  13. A location selection policy of live virtual machine migration for power saving and load balancing.

    PubMed

    Zhao, Jia; Ding, Yan; Xu, Gaochao; Hu, Liang; Dong, Yushuang; Fu, Xiaodong

    2013-01-01

    Green cloud data center has become a research hotspot of virtualized cloud computing architecture. And load balancing has also been one of the most important goals in cloud data centers. Since live virtual machine (VM) migration technology is widely used and studied in cloud computing, we have focused on location selection (migration policy) of live VM migration for power saving and load balancing. We propose a novel approach MOGA-LS, which is a heuristic and self-adaptive multiobjective optimization algorithm based on the improved genetic algorithm (GA). This paper has presented the specific design and implementation of MOGA-LS such as the design of the genetic operators, fitness values, and elitism. We have introduced the Pareto dominance theory and the simulated annealing (SA) idea into MOGA-LS and have presented the specific process to get the final solution, and thus, the whole approach achieves a long-term efficient optimization for power saving and load balancing. The experimental results demonstrate that MOGA-LS evidently reduces the total incremental power consumption and better protects the performance of VM migration and achieves the balancing of system load compared with the existing research. It makes the result of live VM migration more high-effective and meaningful.

  14. Load controller and method to enhance effective capacity of a photovoltaic power supply

    DOEpatents

    Perez, Richard

    2000-01-01

    A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The renewable supply may comprise, for example, a photovoltaic power supply or a wind-based power supply.

  15. POWER SYSTEMS DEVELOPMENT FACILITY

    SciTech Connect

    Unknown

    2002-05-01

    This report discusses test campaign GCT3 of the Halliburton KBR transport reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The transport reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using one of two possible particulate control devices (PCDs). The transport reactor was operated as a pressurized gasifier during GCT3. GCT3 was planned as a 250-hour test run to commission the loop seal and continue the characterization of the limits of operational parameter variations using a blend of several Powder River Basin coals and Bucyrus limestone from Ohio. The primary test objectives were: (1) Loop Seal Commissioning--Evaluate the operational stability of the loop seal with sand and limestone as a bed material at different solids circulation rates and establish a maximum solids circulation rate through the loop seal with the inert bed. (2) Loop Seal Operations--Evaluate the loop seal operational stability during coal feed operations and establish maximum solids circulation rate. Secondary objectives included the continuation of reactor characterization, including: (1) Operational Stability--Characterize the reactor loop and PCD operations with short-term tests by varying coal feed, air/coal ratio, riser velocity, solids circulation rate, system pressure, and air distribution. (2) Reactor Operations--Study the devolatilization and tar cracking effects from transient conditions during transition from start-up burner to coal. Evaluate the effect of process operations on heat release, heat transfer, and accelerated fuel particle heat-up rates. Study the effect of changes in reactor conditions on transient temperature profiles, pressure balance, and product gas composition. (3) Effects of Reactor Conditions on Syngas Composition--Evaluate the effect of air distribution, steam

  16. Sodium borohydride based hybrid power system

    NASA Astrophysics Data System (ADS)

    Richardson, Bradley S.; Birdwell, Joseph F.; Pin, François G.; Jansen, John F.; Lind, Randall F.

    Sodium borohydride's properties make it a good source of hydrogen for use with a fuel cell for an on-demand system that is easily controllable and has no idle costs. Previous work, as described in the literature, indicated that ruthenium (Ru) is an efficient catalyst for generating hydrogen from sodium borohydride. Tests were conducted to evaluate catalyst loading with the results of these tests indicating that the hydrolysis rate is affected by the loading of the catalyst. It was also apparent that the substrate surface is not completely occupied by Ru at the lower loadings, and that increased loadings are needed to optimize the reaction rate. A differential rate test with a fixed bed reactor was also conducted. It was observed that temperature has a significant effect on the rate of reaction. Feed rate also affected the rate of reaction with lower feed rates (longer residence time in the reactor) having higher reaction rates. A bench-top hybrid system was also developed and tested. This test bed demonstrated how a system based on a chemically generated hydrogen-fed proton exchange membrane fuel cell could be integrated with batteries to provide a hybrid power system that can meet the demands of a highly varying electrical load up to four times the rated output of the fuel cell.

  17. Multi-time scale dynamics in power electronics-dominated power systems

    NASA Astrophysics Data System (ADS)

    Yuan, Xiaoming; Hu, Jiabing; Cheng, Shijie

    2017-09-01

    Electric power infrastructure has recently undergone a comprehensive transformation from electromagnetics to semiconductors. Such a development is attributed to the rapid growth of power electronic converter applications in the load side to realize energy conservation and on the supply side for renewable generations and power transmissions using high voltage direct current transmission. This transformation has altered the fundamental mechanism of power system dynamics, which demands the establishment of a new theory for power system control and protection. This paper presents thoughts on a theoretical framework for the coming semiconducting power systems.

  18. Multi-time scale dynamics in power electronics-dominated power systems

    NASA Astrophysics Data System (ADS)

    Yuan, Xiaoming; Hu, Jiabing; Cheng, Shijie

    2017-07-01

    Electric power infrastructure has recently undergone a comprehensive transformation from electromagnetics to semiconductors. Such a development is attributed to the rapid growth of power electronic converter applications in the load side to realize energy conservation and on the supply side for renewable generations and power transmissions using high voltage direct current transmission. This transformation has altered the fundamental mechanism of power system dynamics, which demands the establishment of a new theory for power system control and protection. This paper presents thoughts on a theoretical framework for the coming semiconducting power systems.

  19. Alteration of LV end-diastolic volume by controlling the power of the continuous-flow LVAD, so it is synchronized with cardiac beat: development of a native heart load control system (NHLCS).

    PubMed

    Umeki, Akihide; Nishimura, Takashi; Ando, Masahiko; Takewa, Yoshiaki; Yamazaki, Kenji; Kyo, Shunei; Ono, Minoru; Tsukiya, Tomonori; Mizuno, Toshihide; Taenaka, Yoshiyuki; Tatsumi, Eisuke

    2012-06-01

    There are many reports comparing pulsatile and continuous-flow left ventricular assist devices (LVAD). But continuous-flow LVAD with the pulsatile driving technique had not been tried or discussed before our group's report. We have previously developed and introduced a power-control unit for a centrifugal LVAD (EVAHEART®; Sun Medical), which can change the speed of rotation so it is synchronized with the heart beat. By use of this unit we analyzed the end-diastolic volume (EDV) to determine whether it is possible to change the native heart load. We studied 5 goats with normal hearts and 5 goats with acute LV dysfunction because of micro-embolization of the coronary artery. We used 4 modes, "circuit-clamp", "continuous", "counter-pulse", and "co-pulse", with the bypass rate (BR) 100%. We raised the speed of rotation of the LVAD in the diastolic phase with the counter-pulse mode, and raised it in the systolic phase with the co-pulse mode. As a result, the EDV decreased in the counter-pulse mode and increased in the co-pulse mode, compared with the continuous mode (p < 0.05), in both the normal and acute-heart-failure models. This result means it may be possible to achieve favorable EDV and native heart load by controlling the rotation of continuous-flow LVAD, so it is synchronized with the cardiac beat. This novel driving system may be of great benefit to patients with end-stage heart failure, especially those with ischemic etiology.

  20. Space Station Power System issues

    NASA Technical Reports Server (NTRS)

    Forestieri, A. F.

    1985-01-01

    A number of attractive options are available for the Space Station Power System. These include a photovoltaic system or solar dynamic system for power generation, batteries or fuel cells for energy storage and ac or dc for power management and distribution. These options are being explored during the present preliminary design and definition phase of the Space Station Program. Final selections are presently targeted for January 1986.

  1. Operating health analysis of electric power systems

    NASA Astrophysics Data System (ADS)

    Fotuhi-Firuzabad, Mahmud

    The required level of operating reserve to be maintained by an electric power system can be determined using both deterministic and probabilistic techniques. Despite the obvious disadvantages of deterministic approaches there is still considerable reluctance to apply probabilistic techniques due to the difficulty of interpreting a single numerical risk index and the lack of sufficient information provided by a single index. A practical way to overcome difficulties is to embed deterministic considerations in the probabilistic indices in order to monitor the system well-being. The system well-being can be designated as healthy, marginal and at risk. The concept of system well-being is examined and extended in this thesis to cover the overall area of operating reserve assessment. Operating reserve evaluation involves the two distinctly different aspects of unit commitment and the dispatch of the committed units. Unit commitment health analysis involves the determination of which unit should be committed to satisfy the operating criteria. The concepts developed for unit commitment health, margin and risk are extended in this thesis to evaluate the response well-being of a generating system. A procedure is presented to determine the optimum dispatch of the committed units to satisfy the response criteria. The impact on the response wellbeing being of variations in the margin time, required regulating margin and load forecast uncertainty are illustrated. The effects on the response well-being of rapid start units, interruptible loads and postponable outages are also illustrated. System well-being is, in general, greatly improved by interconnection with other power systems. The well-being concepts are extended to evaluate the spinning reserve requirements in interconnected systems. The interconnected system unit commitment problem is decomposed into two subproblems in which unit scheduling is performed in each isolated system followed by interconnected system evaluation

  2. Nanosatellite Power System Considerations

    NASA Technical Reports Server (NTRS)

    Robyn, M.; Thaller, L.; Scott, D.

    1995-01-01

    The capability to build complex electronic functions into compact packages is opening the path to miniature satellites on the order of 1 kg mass, 10 cm across, packed with the computing processors, motion controllers, measurement sensors, and communications hardware necessary for operation. Power generation will be from short strings of silicon or gallium arsenide-based solar photovoltaic cells with the array power maximized by a peak power tracker (PPT). Energy storage will utilize a low voltage battery with nickel cadmium or lithium ion cells as the most likely selections for rechargeables and lithium (MnO2-Li) primary batteries for one shot short missions.

  3. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near power lines with no load. (a) This section establishes procedures and criteria that must be met for...

  4. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near power lines with no load. (a) This section establishes procedures and criteria that must be met for...

  5. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near power lines with no load. (a) This section establishes procedures and criteria that must be met for...

  6. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or near power lines with no load. (a) This section establishes procedures and criteria that must be met for...

  7. Design of power control system using SMES and SVC for fusion power plant

    NASA Astrophysics Data System (ADS)

    Niiyama, K.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2008-02-01

    A SMES (Superconducting Magnetic Energy Storage System) system with converter composed of self-commutated valve devices such as GTO and IGBT is available to control active and reactive power simultaneously. A SVC (Static Var Compensators) or STATCOM (Static Synchronous Compensator) is widely employed to reduce reactive power in power plants and substations. Owing to progress of power electronics technology using GTO and IGBT devices, power converters in the SMES system and the SVC can easily control power flow in few milliseconds. Moreover, since the valve devices for the SMES are equivalent to those for the SVC, the device cost must be reduced. In this paper the basic control system combined with the SMES and SVC is designed for large pulsed loads of a nuclear fusion power plant. This combined system largely expands the reactive power control region as well as the active one. The simulation results show that the combined system is effective and prospective for the nuclear fusion power plant.

  8. Spur-Gear-System Efficiency at Part and Full Load

    NASA Technical Reports Server (NTRS)

    Anderson, N. E.; Loewenthal, S. H.

    1980-01-01

    A simple method for predicting the part- and full-load power loss of a steel spur gearset of arbitrary geometry supported by ball bearings is described. The analysis algebraically accounts for losses due to gear sliding, rolling traction, and windage in addition to support-ball-bearing losses. The analysis compares favorably with test data. A theoretical comparison of the component losses indicates that losses due to gear rolling traction, windage, and support bearings are significant and should be included along with gear sliding loss in a calculation of gear-system power loss.

  9. Space solar power systems

    NASA Technical Reports Server (NTRS)

    Toliver, C.

    1977-01-01

    Studies were done on the feasibility of placing a solar power station called POwersat, in space. A general description of the engineering features are given as well as a brief discussion of the economic considerations.

  10. Power system monitoring and source control of the Space Station Freedom dc-power system testbed

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  11. Power system monitoring and source control of the Space Station Freedom DC power system testbed

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  12. Power system monitoring and source control of the Space Station Freedom dc-power system testbed

    NASA Technical Reports Server (NTRS)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the dc Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  13. A Novel Multiobjective Control of DVR to Enhance Power Quality of Sensitive Load.

    PubMed

    Pandu, Sathish Babu; Nagappan, Kamaraj

    2015-01-01

    The Dynamic Voltage Restorer (DVR) is one of the fast, flexible, and cost effective solutions available in compensating the voltage-related power quality problems in power distribution systems. In this paper is discussed how power quality enhancement of sensitive load is achieved by applying three versions of Autonomous Group Particle Swarm Optimization like AGPSO1, AGPSO2, and AGPSO3 for tuning the Proportional-Integral DVR controller under balanced and nonlinear load conditions. A novel multiobjective function is formulated to express the control performance of the system, which is quantified using three power quality indices such as Total Harmonic Distortion (THD), voltage sag index, and RMS voltage variation. The obtained results are compared with the Proportional-Integral (PI) controller tuned by Ziegler-Nichols (ZN) method and also by Simple Particle Swarm Optimization based PI controlled DVR. The proposed methodology has improved the performance in terms of the considered power quality indices and the simulation has been carried out in MATLAB/Simulink environment.

  14. A Novel Multiobjective Control of DVR to Enhance Power Quality of Sensitive Load

    PubMed Central

    Pandu, Sathish Babu; Nagappan, Kamaraj

    2015-01-01

    The Dynamic Voltage Restorer (DVR) is one of the fast, flexible, and cost effective solutions available in compensating the voltage-related power quality problems in power distribution systems. In this paper is discussed how power quality enhancement of sensitive load is achieved by applying three versions of Autonomous Group Particle Swarm Optimization like AGPSO1, AGPSO2, and AGPSO3 for tuning the Proportional-Integral DVR controller under balanced and nonlinear load conditions. A novel multiobjective function is formulated to express the control performance of the system, which is quantified using three power quality indices such as Total Harmonic Distortion (THD), voltage sag index, and RMS voltage variation. The obtained results are compared with the Proportional-Integral (PI) controller tuned by Ziegler-Nichols (ZN) method and also by Simple Particle Swarm Optimization based PI controlled DVR. The proposed methodology has improved the performance in terms of the considered power quality indices and the simulation has been carried out in MATLAB/Simulink environment. PMID:26613100

  15. Implementing a Nuclear Power Plant Model for Evaluating Load-Following Capability on a Small Grid

    NASA Astrophysics Data System (ADS)

    Arda, Samet Egemen

    A pressurized water reactor (PWR) nuclear power plant (NPP) model is introduced into Positive Sequence Load Flow (PSLF) software by General Electric in order to evaluate the load-following capability of NPPs. The nuclear steam supply system (NSSS) consists of a reactor core, hot and cold legs, plenums, and a U-tube steam generator. The physical systems listed above are represented by mathematical models utilizing a state variable lumped parameter approach. A steady-state control program for the reactor, and simple turbine and governor models are also developed. Adequacy of the isolated reactor core, the isolated steam generator, and the complete PWR models are tested in Matlab/Simulink and dynamic responses are compared with the test results obtained from the H. B. Robinson NPP. Test results illustrate that the developed models represents the dynamic features of real-physical systems and are capable of predicting responses due to small perturbations of external reactivity and steam valve opening. Subsequently, the NSSS representation is incorporated into PSLF and coupled with built-in excitation system and generator models. Different simulation cases are run when sudden loss of generation occurs in a small power system which includes hydroelectric and natural gas power plants besides the developed PWR NPP. The conclusion is that the NPP can respond to a disturbance in the power system without exceeding any design and safety limits if appropriate operational conditions, such as achieving the NPP turbine control by adjusting the speed of the steam valve, are met. In other words, the NPP can participate in the control of system frequency and improve the overall power system performance.

  16. Integration of ocean thermal energy conversion power plants with existing power systems

    SciTech Connect

    Arunasalam, N.

    1986-01-01

    The problem of integrating an Ocean Thermal Energy Conversion (OTEC) power plant with existing power systems is studied. A nonlinear model of an OTEC power system is developed. The dynamics of the large local induction motor load, and the coaxial cable connection to the mainland are included in the model. The effect of the motor load and the coaxial cable on the steady-state stability of the OTEC power plant is investigated using linearized analysis. The transient stability of the OTEC system is investigated through simulation. The contribution made by the motor load and the coaxial cable to the transient stability is studied. The occurrence of self excitation phenomena is analyzed using linear methods and simulation. The effects of wave and vessel motion on the electrical power output of the OTEC plant is investigated.

  17. Photovoltaic power system reliability considerations

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.

    1980-01-01

    An example of how modern engineering and safety techniques can be used to assure the reliable and safe operation of photovoltaic power systems is presented. This particular application is for a solar cell power system demonstration project designed to provide electric power requirements for remote villages. The techniques utilized involve a definition of the power system natural and operating environment, use of design criteria and analysis techniques, an awareness of potential problems via the inherent reliability and FMEA methods, and use of fail-safe and planned spare parts engineering philosophy.

  18. Electric Power Load Analysis (EPLA) for Surface Ships

    DTIC Science & Technology

    2012-09-17

    b. Air operation for aircraft carriers. c. Debarking operation for cargo and amphibious warfare ships. DDS 310-1 REV 1 7 d. Replenishment-at-sea...carrier. Emergency ship control and the larger electrical load associate with selected weapons or limited air operations (recovery and strike down of...operating load to the connected load of the equipment. If the load is intermittent or cyclic, such as an air compressor motor, the factor shall be selected

  19. High-Speed Resistance Training Modifies Load-Velocity and Load-Power Relationships in Parkinson's Disease.

    PubMed

    Ni, Meng; Signorile, Joseph F

    2017-10-01

    Ni, M and Signorile, JF. High-speed resistance training modifies load-velocity and load-power relationships in Parkinson's disease. J Strength Cond Res 31(10): 2866-2875, 2017-Muscle power is a major neuromuscular factor affecting motor function and independence in patients with Parkinson's disease (PD), and it is commonly targeted using high-speed exercise. This study examined the changes in velocities (Vpp) and percent loads (%1RMpp) at peak power and load-velocity (L-V) and load-power (L-P) relationships, resulting from resistance training because of exercise choice and loading in older patients with PD. Fourteen older adults with mild to moderate PD participated in a 12-week randomized controlled power training trial. Changes in L-V and L-P relationships for the biceps curl, chest press, leg press, hip abduction, and seated calf were assessed using pneumatic resistance machines at loads ranging from 30 through 90% of subjects' 1 repetition maximum for each exercise. Significant increases in Vpp were seen for biceps curl, leg press, hip abduction, and seated calf and decreases in %1RMpp were noted for biceps curl and hip abduction. Additionally, unique patterns of change were seen in these relationships across exercises, with biceps curl, chest press, and leg press showing the greatest shifts at the lower load end of the loading spectrum, and hip abduction and seated calf showing greatest responses at the higher end. The patterns of change in L-V and L-P relationships provide evidence for the unique responses of the specific muscle groups and joints to the exercises evaluated and offer a framework for more exacting exercise prescriptions in patients with PD.

  20. Fault Diagnosis of Power Systems Using Intelligent Systems

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Oliver, Walter E. , Jr.

    1996-01-01

    The power system operator's need for a reliable power delivery system calls for a real-time or near-real-time Al-based fault diagnosis tool. Such a tool will allow NASA ground controllers to re-establish a normal or near-normal degraded operating state of the EPS (a DC power system) for Space Station Alpha by isolating the faulted branches and loads of the system. And after isolation, re-energizing those branches and loads that have been found not to have any faults in them. A proposed solution involves using the Fault Diagnosis Intelligent System (FDIS) to perform near-real time fault diagnosis of Alpha's EPS by downloading power transient telemetry at fault-time from onboard data loggers. The FDIS uses an ANN clustering algorithm augmented with a wavelet transform feature extractor. This combination enables this system to perform pattern recognition of the power transient signatures to diagnose the fault type and its location down to the orbital replaceable unit. FDIS has been tested using a simulation of the LeRC Testbed Space Station Freedom configuration including the topology from the DDCU's to the electrical loads attached to the TPDU's. FDIS will work in conjunction with the Power Management Load Scheduler to determine what the state of the system was at the time of the fault condition. This information is used to activate the appropriate diagnostic section, and to refine if necessary the solution obtained. In the latter case, if the FDIS reports back that it is equally likely that the faulty device as 'start tracker #1' and 'time generation unit,' then based on a priori knowledge of the system's state, the refined solution would be 'star tracker #1' located in cabinet ITAS2. It is concluded from the present studies that artificial intelligence diagnostic abilities are improved with the addition of the wavelet transform, and that when such a system such as FDIS is coupled to the Power Management Load Scheduler, a faulty device can be located and isolated

  1. Fault Diagnosis of Power Systems Using Intelligent Systems

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Oliver, Walter E. , Jr.

    1996-01-01

    The power system operator's need for a reliable power delivery system calls for a real-time or near-real-time Al-based fault diagnosis tool. Such a tool will allow NASA ground controllers to re-establish a normal or near-normal degraded operating state of the EPS (a DC power system) for Space Station Alpha by isolating the faulted branches and loads of the system. And after isolation, re-energizing those branches and loads that have been found not to have any faults in them. A proposed solution involves using the Fault Diagnosis Intelligent System (FDIS) to perform near-real time fault diagnosis of Alpha's EPS by downloading power transient telemetry at fault-time from onboard data loggers. The FDIS uses an ANN clustering algorithm augmented with a wavelet transform feature extractor. This combination enables this system to perform pattern recognition of the power transient signatures to diagnose the fault type and its location down to the orbital replaceable unit. FDIS has been tested using a simulation of the LeRC Testbed Space Station Freedom configuration including the topology from the DDCU's to the electrical loads attached to the TPDU's. FDIS will work in conjunction with the Power Management Load Scheduler to determine what the state of the system was at the time of the fault condition. This information is used to activate the appropriate diagnostic section, and to refine if necessary the solution obtained. In the latter case, if the FDIS reports back that it is equally likely that the faulty device as 'start tracker #1' and 'time generation unit,' then based on a priori knowledge of the system's state, the refined solution would be 'star tracker #1' located in cabinet ITAS2. It is concluded from the present studies that artificial intelligence diagnostic abilities are improved with the addition of the wavelet transform, and that when such a system such as FDIS is coupled to the Power Management Load Scheduler, a faulty device can be located and isolated

  2. Energy analysis of load-induced flutter instability in classical models of electric power networks

    SciTech Connect

    Kwatny, H.G.; Yu, X.M. )

    1989-12-01

    In this paper, the authors consider the local structure of energy functions for electric power networks near points (parameter values) of incipient flutter instability. Previous work by several investigators clearly indicate the subtle nature of energy functions and energy- like Lyapunov functions when the system exhibits such an instability mechanism. In fact the question of existence of an energy function under these circumstances has been raised. The issue is important because it is now well known that power systems with loads contain such bifurcation points. It is shown, herein, that a local energy function does exist in a sense consistent with the inverse problem of analytical mechanics. However, sufficiently near points of flutter instability the energy function for both stable and unstable systems is not sign definite. Such an energy function can not be used as a Lyapunov function. Nevertheless, it is possible to obtain natural Lyapunov functions by combining the energy function with one or more additional first integrals. The analysis is based on the association of the linearized undamped power system with loads with a quadratic Hamiltonian system. General (universal) perturbations of the normal forms of the degenerate quadratic Hamiltonians at such bifurcation points are derived and lead to the stated conclusions. An example is included.

  3. Galileo spacecraft power management and distribution system

    NASA Technical Reports Server (NTRS)

    Detwiler, R. C.; Smith, R. L.

    1990-01-01

    The Galileo PMAD (power management and distribution system) is described, and the design drivers that established the final as-built hardware are discussed. The spacecraft is powered by two general-purpose heat-source-radioisotope thermoelectric generators. Power bus regulation is provided by a shunt regulator. Galileo PMAD distributes a 570-W beginning of mission (BOM) power source to a user complement of some 137 load elements. Extensive use of pyrotechnics requires two pyro switching subassemblies. They initiate 148 squibs which operate the 47 pyro devices on the spacecraft. Detection and correction of faults in the Galileo PMAD is an autonomous feature dictated by requirements for long life and reliability in the absence of ground-based support. Volatile computer memories in the spacecraft command and data system and attitude control system require a continuous source of backup power during all anticipated power bus fault scenarios. Power for the Jupiter Probe is conditioned, isolated, and controlled by a Probe interface subassembly. Flight performance of the spacecraft and the PMAD has been successful to date, with no major anomalies.

  4. Power outputs of a machine squat-jump across a spectrum of loads.

    PubMed

    Harris, Nigel K; Cronin, John B; Hopkins, Will G

    2007-11-01

    The load that maximizes mechanical power output (Pmax) has received considerable research attention owing to its perceived importance to training prescription. However, it may be that identifying Pmax is of little importance if the difference in power output about Pmax is insubstantial. Additionally, comparing the effect of load on power output between studies is problematic due to various methodological differences. The purpose of this study therefore was to quantify the concentric power output for a machine squat-jump across a spectrum of loads (10-100% of 1 repetition maximum [1RM]). To estimate Pmax load and proximate loads a quadratic was fitted to the power output (Watts) and load (% of 1RM) of 18 well-trained rugby athletes. Pmax for peak and mean power output occurred at 21.6 +/- 7.1% of 1RM (mean +/- SD) and 39.0 +/- 8.6% of 1RM, respectively. A 20% change in load either side of the maximum resulted in a mean decrease of only 9.9% (90% confidence limits +/-2.4%) and 5.4% (+/-0.9%) in peak and mean power respectively; standard deviations about these means (representing individual differences in the decrease) were 6.0% and 2.1%, respectively (90% confidence limits x//1.34). It appears that most athletes have a broad peak in their power profile for peak or mean power. The preoccupation of identifying one load for maximizing power output would seem less meaningful than many practitioners and scientists believe.

  5. The space station power system

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The requirements for electrical power by the proposed Space Station Freedom are discussed. The options currently under consideration are examined. The three power options are photovoltaic, solar dynamic, and a hybrid system. Advantages and disadvantages of each system are tabulated. Drawings and artist concepts of the Space Station configuration are provided.

  6. Maintenance of photovoltaic power systems

    NASA Astrophysics Data System (ADS)

    Hall, M. R.

    1984-08-01

    This publication establishes standard practices for inspection, testing, and maintenance of photovoltaic power systems at Dept. of the Navy installations. The practices and procedures are recommended to ensure reliable operation of the power systems. The manual covers photovoltaic-array, battery, voltage-regulator, inverter, and wiring subsystems. In addition, this manual provides a troubleshooting guide and self-study questions and answers.

  7. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

    SciTech Connect

    Yang, Rui; Zhang, Yingchen

    2016-08-01

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  8. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems

    SciTech Connect

    Yang, Rui; Zhang, Yingchen

    2016-11-14

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  9. Radial current high power dummy load for characterizing the high power laser triggered transformer-type accelerator

    NASA Astrophysics Data System (ADS)

    Yin, Yi; Zhong, Hui-Huang; Liu, Jin-Liang; Ren, He-Ming; Yang, Jian-Hua; Zhang, Xiao-Ping; Hong, Zhi-qiang

    2010-09-01

    A radial-current aqueous resistive solution load was applied to characterize a laser triggered transformer-type accelerator. The current direction in the dummy load is radial and is different from the traditional load in the axial. Therefore, this type of dummy load has smaller inductance and fast response characteristic. The load was designed to accommodate both the resistance requirement of accelerator and to allow optical access for the laser. Theoretical and numerical calculations of the load's inductance and capacitance are given. The equivalent circuit of the dummy load is calculated in theory and analyzed with a PSPICE code. The simulation results agree well with the theoretical analysis. At last, experiments of the dummy load applied to the high power spiral pulse forming line were performed; a quasisquare pulse voltage is obtained at the dummy load.

  10. Reactive power compensating system

    DOEpatents

    Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.

    1987-01-01

    The reactive power of an induction machine is compensated by providing fixed capacitors on each phase line for the minimum compensation required, sensing the current on one line at the time its voltage crosses zero to determine the actual compensation required for each phase, and selecting switched capacitors on each line to provide the balance of the compensation required.

  11. Optimization of power systems with voltage security constraints

    NASA Astrophysics Data System (ADS)

    Rosehart, William Daniel

    As open access market principles are applied to power systems, significant changes in their operation and control are occurring. In the new marketplace, power systems are operating under higher loading conditions as market influences demand greater attention to operating cost versus stability margins. Since stability continues to be a basic requirement in the operation of any power system, new tools are being considered to analyze the effect of stability on the operating cost of the system, so that system stability can be incorporated into the costs of operating the system. In this thesis, new optimal power flow (OPF) formulations are proposed based on multi-objective methodologies to optimize active and reactive power dispatch while maximizing voltage security in power systems. The effects of minimizing operating costs, minimizing reactive power generation and/or maximizing voltage stability margins are analyzed. Results obtained using the proposed Voltage Stability Constrained OPF formulations are compared and analyzed to suggest possible ways of costing voltage security in power systems. When considering voltage stability margins the importance of system modeling becomes critical, since it has been demonstrated, based on bifurcation analysis, that modeling can have a significant effect of the behavior of power systems, especially at high loading levels. Therefore, this thesis also examines the effects of detailed generator models and several exponential load models. Furthermore, because of its influence on voltage stability, a Static Var Compensator model is also incorporated into the optimization problems.

  12. Limits to power system growth

    SciTech Connect

    Slater, S.M.; Klein, A.C. ); Webb, B.J. ); Pauley, K.A. )

    1993-01-15

    In the design of space nuclear power systems a variety of conversion techniques may be used, each with its own advantages and disadvantages. A study was performed which analyzed over 120 proposed system designs. The designs were compared to identify the optimum conversion system as a function of power level and find limits to specific mass (kg/kWe) for each power cycle. Furthermore, the component masses were studied to determine which component of the overall design contributes the most to total system mass over a variety of power levels. The results can provide a focus for future research efforts by selecting the best conversion technology for the desired power range, and optimizing the system component which contributes most to the total mass.

  13. Electrical power systems for Mars

    NASA Astrophysics Data System (ADS)

    Giudici, Robert J.

    1986-05-01

    Electrical power system options for Mars Manned Modules and Mars Surface Bases were evaluated for both near-term and advanced performance potential. The power system options investigated for the Mission Modules include photovoltaics, solar thermal, nuclear reactor, and isotope power systems. Options discussed for Mars Bases include the above options with the addition of a brief discussion of open loop energy conversion of Mars resources, including utilization of wind, subsurface thermal gradients, and super oxides. Electrical power requirements for Mission Modules were estimated for three basic approaches: as a function of crew size; as a function of electric propulsion; and as a function of transmission of power from an orbiter to the surface of Mars via laser or radio frequency. Mars Base power requirements were assumed to be determined by production facilities that make resources available for follow-on missions leading to the establishment of a permanently manned Base. Requirements include the production of buffer gas and propellant production plants.

  14. Electrical power systems for Mars

    NASA Technical Reports Server (NTRS)

    Giudici, Robert J.

    1986-01-01

    Electrical power system options for Mars Manned Modules and Mars Surface Bases were evaluated for both near-term and advanced performance potential. The power system options investigated for the Mission Modules include photovoltaics, solar thermal, nuclear reactor, and isotope power systems. Options discussed for Mars Bases include the above options with the addition of a brief discussion of open loop energy conversion of Mars resources, including utilization of wind, subsurface thermal gradients, and super oxides. Electrical power requirements for Mission Modules were estimated for three basic approaches: as a function of crew size; as a function of electric propulsion; and as a function of transmission of power from an orbiter to the surface of Mars via laser or radio frequency. Mars Base power requirements were assumed to be determined by production facilities that make resources available for follow-on missions leading to the establishment of a permanently manned Base. Requirements include the production of buffer gas and propellant production plants.

  15. The ATS-6 power system - An optimized design for maximum power source utilization

    NASA Technical Reports Server (NTRS)

    Lavigna, T. A.

    1975-01-01

    The modified power system design adopted for the ATS-6 satellite is described. This design featured a shunt-boost configuration to provide direct power from the solar array to the loads for maximum efficiency. In addition, shunt power dissipators were used, not only as a means of power system regulation, but also for thermal control. A brief description of the spacecraft and of the initial series regulator power system design (which was unable to meet mission requirements) precede the discussion. The shunt boost system provides excellent utilization of array power with an 8 to 10% increase in efficiency over the original configuration; good array-battery static and dynamic load sharing; excellent flexibility in accommodating mission requirements; and low electromagnetic interference.

  16. Assessing the variation in the load that produces maximal upper-body power.

    PubMed

    Argus, Christos K; Gill, Nicholas D; Keogh, Justin W L; Hopkins, Will G

    2014-01-01

    Substantial variation in the load that produces maximal power has been reported. It has been suggested that the variation observed may be due to differences in subjects' physical characteristics. Therefore, the aim of this study was to determine the extent in which anthropometric measures correlate with the load that produces maximal power. Anthropometric measures (upper-arm length, forearm length, total arm length, and upper-arm girth) and bench press strength were assessed in 26 professional rugby union players. Peak power was then determined in the bench press throw exercise using loads of 20-60% of one repetition maximum (1RM) in the bench press exercise. Maximal power occurred at 30 ± 14% 1RM (mean ± SD). Upper-arm length had the highest correlation with the load maximizing power: -0.61 (90% confidence limits -0.35 to -0.78), implying loads of 22 vs. 38% 1RM maximize power for players with typically long vs. short upper-arm length. Correlations for forearm length, total arm length, and upper-arm girth to the load that maximized power were -0.29 (0.04 to -0.57), -0.56 (-0.28 to -0.75), and -0.29 (0.04 to -0.57), respectively. The relationship between 1RM and the load that produced maximal power was r = -0.23 (0.10 to -0.52). The between-subject variation in the load that maximized power observed (SD = ±14% of 1RM) may have been due to differences in anthropometric characteristics, and absolute strength and power outputs. Indeed, athletes with longer limbs and larger girths and greater maximal strength and power outputs used a lower percentage of 1RM loads to achieve maximum power. Therefore, we recommend individual assessment of the load that maximizes power output.

  17. Arcing on dc power systems

    NASA Technical Reports Server (NTRS)

    Moores, Greg; Heller, R. P.; Sutanto, Surja; Dugal-Whitehead, Norma R.

    1992-01-01

    Unexpected and undesirable arcing on dc power systems can produce hazardous situations aboard space flights. The potential for fire and shock might exist in a situation where there is a broken conductor, a loose power connection, or a break in the insulation of the power cable. Such arcing has been found to be reproducible in a laboratory environment. Arcing tests show that the phenomena can last for several seconds and yet be undetectable by present protection schemes used in classical power relaying and remote power controller applications. This paper characterizes the arcing phenomena and suggests future research that is needed.

  18. Arcing on dc power systems

    NASA Technical Reports Server (NTRS)

    Moores, Greg; Heller, R. P.; Sutanto, Surja; Dugal-Whitehead, Norma R.

    1992-01-01

    Unexpected and undesirable arcing on dc power systems can produce hazardous situations aboard space flights. The potential for fire and shock might exist in a situation where there is a broken conductor, a loose power connection, or a break in the insulation of the power cable. Such arcing has been found to be reproducible in a laboratory environment. Arcing tests show that the phenomena can last for several seconds and yet be undetectable by present protection schemes used in classical power relaying and remote power controller applications. This paper characterizes the arcing phenomena and suggests future research that is needed.

  19. Communication Simulations for Power System Applications

    SciTech Connect

    Fuller, Jason C.; Ciraci, Selim; Daily, Jeffrey A.; Fisher, Andrew R.; Hauer, Matthew L.

    2013-05-29

    New smart grid technologies and concepts, such as dynamic pricing, demand response, dynamic state estimation, and wide area monitoring, protection, and control, are expected to require considerable communication resources. As the cost of retrofit can be high, future power grids will require the integration of high-speed, secure connections with legacy communication systems, while still providing adequate system control and security. While considerable work has been performed to create co-simulators for the power domain with load models and market operations, limited work has been performed in integrating communications directly into a power domain solver. The simulation of communication and power systems will become more important as the two systems become more inter-related. This paper will discuss ongoing work at Pacific Northwest National Laboratory to create a flexible, high-speed power and communication system co-simulator for smart grid applications. The framework for the software will be described, including architecture considerations for modular, high performance computing and large-scale scalability (serialization, load balancing, partitioning, cross-platform support, etc.). The current simulator supports the ns-3 (telecommunications) and GridLAB-D (distribution systems) simulators. Ongoing and future work will be described, including planned future expansions for a traditional transmission solver. A test case using the co-simulator, utilizing a transactive demand response system created for the Olympic Peninsula and AEP gridSMART demonstrations, requiring two-way communication between distributed and centralized market devices, will be used to demonstrate the value and intended purpose of the co-simulation environment.

  20. The characterization of secondary lithium-ion battery degradation when operating complex, ultra-high power pulsed loads

    NASA Astrophysics Data System (ADS)

    Wong, Derek N.

    The US Navy is actively developing all electric fleets, raising serious questions about what is required of onboard power supplies in order to properly power the ship's electrical systems. This is especially relevant when choosing a viable power source to drive high power propulsion and electric weapon systems in addition to the conventional loads deployed aboard these types of vessels. Especially when high pulsed power loads are supplied, the issue of maintaining power quality becomes important and increasingly complex. Conventionally, a vessel's electrical power is generated using gas turbine or diesel driven motor-generator sets that are very inefficient when they are used outside of their most efficient load condition. What this means is that if the generator is not being utilized continuously at its most efficient load capacity, the quality of the output power may also be effected and fall outside of the acceptable power quality limits imposed through military standards. As a solution to this potential problem, the Navy has proposed using electrochemical storage devices since they are able to buffer conventional generators when the load is operating below the generator's most efficient power level or able to efficiently augment a generator when the load is operating in excess of the generator's most efficient power rating. Specifically, the US Navy is interested in using commercial off-the-shelf (COTS) lithium-ion batteries within an intelligently controlled energy storage module that could act as either a prime power supply for on-board pulsed power systems or as a backup generator to other shipboard power systems. Due to the unique load profile of high-rate pulsed power systems, the implementation of lithium-ion batteries within these complex systems requires them to be operated at very high rates and the effects these things have on cell degradation has been an area of focus. There is very little published research into the effects that high power transient

  1. The theoretical limits to the power output of a muscle-tendon complex with inertial and gravitational loads.

    PubMed Central

    Galantis, Apostolos; Woledge, Roger C

    2003-01-01

    When a muscle delivers power to an inertial load through a spring, the peak power can exceed the maximum that the muscle alone could produce. Using normalized differential equations relating dimensionless quantities we show, by solving the equations either analytically or numerically, that one dimensionless constant (Xi), representing the inertial load, is sufficient to specify the behaviour during shortening of a muscle-tendon complex with linear force-velocity and force-extension properties. In the presence of gravity, an additional constant (Gamma), representing the gravitational acceleration, is required. Nonlinear force-velocity and force-extension relationships each introduce an additional constant, representing their curvature. In the absence of gravity the power output delivered to an inertial load is limited to approximately 1.4 times the maximum power of the muscle alone, and when gravity is present the power delivered is limited to approximately twice the power of muscle alone. These limits are found for the purely inertial load at Xi ca. 1 and with gravity acting at XiGamma = 0.5 with Xi arbitrarily small. The effects of nonlinear muscle and tendon properties tend to cancel each other out and do not produce large deviations from these optima. A lever system of constant ratio between muscle and load does not alter these limits. Cams and catches are required to exceed these limits and attain the high power outputs sometimes observed during explosive animal movement. PMID:12965015

  2. The theoretical limits to the power output of a muscle-tendon complex with inertial and gravitational loads.

    PubMed

    Galantis, Apostolos; Woledge, Roger C

    2003-07-22

    When a muscle delivers power to an inertial load through a spring, the peak power can exceed the maximum that the muscle alone could produce. Using normalized differential equations relating dimensionless quantities we show, by solving the equations either analytically or numerically, that one dimensionless constant (Xi), representing the inertial load, is sufficient to specify the behaviour during shortening of a muscle-tendon complex with linear force-velocity and force-extension properties. In the presence of gravity, an additional constant (Gamma), representing the gravitational acceleration, is required. Nonlinear force-velocity and force-extension relationships each introduce an additional constant, representing their curvature. In the absence of gravity the power output delivered to an inertial load is limited to approximately 1.4 times the maximum power of the muscle alone, and when gravity is present the power delivered is limited to approximately twice the power of muscle alone. These limits are found for the purely inertial load at Xi ca. 1 and with gravity acting at XiGamma = 0.5 with Xi arbitrarily small. The effects of nonlinear muscle and tendon properties tend to cancel each other out and do not produce large deviations from these optima. A lever system of constant ratio between muscle and load does not alter these limits. Cams and catches are required to exceed these limits and attain the high power outputs sometimes observed during explosive animal movement.

  3. National Launch System cycle 1 loads and models data book

    NASA Technical Reports Server (NTRS)

    Bugg, F.; Brunty, J.; Ernsberger, G.; Mcghee, D.; Gagliano, L.; Harrington, F.; Meyer, D.; Blades, E.

    1992-01-01

    This document contains preliminary cycle 1 loads for the National Launch System (NLS) 1 and 2 vehicles. The loads provided and recommended as design loads represent the maximum load expected during prelaunch and flight regimes, i.e., limit loads, except that propellant tank ullage pressure has not been included. Ullage pressure should be added to the loads book values for cases where the addition results in higher loads. The loads must be multiplied by the appropriate factors of safety to determine the ultimate loads for which the structure must be capable.

  4. Power Aware Distributed Systems

    DTIC Science & Technology

    2004-01-01

    employment of codes developed for correction of doubled errors or interleaving can be useful in the considered case. 2.3.3.3 Differential QPSK 2.3.3.3.1...Electronics Center, Leuven, Belgium) on memory optimization techniques for turbo codes . Currently, he is pursuing his Ph.D. degree UCLA, focusing on...DISTRIBUTION UNLIMITED. 12b. DISTRIBUTION CODE 13. ABSTRACT (Maximum 200 Words) The goal of PADS was to study power aware management techniques

  5. 14 CFR 23.395 - Control system loads.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.395 Control system loads. (a) Each flight control system and its supporting structure must...

  6. 14 CFR 23.395 - Control system loads.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.395 Control system loads. (a) Each flight control system and its supporting structure must...

  7. 14 CFR 23.395 - Control system loads.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.395 Control system loads. (a) Each flight control system and its supporting structure must...

  8. 14 CFR 23.395 - Control system loads.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.395 Control system loads. (a) Each flight control system and its supporting structure must...

  9. 14 CFR 23.395 - Control system loads.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Structure Control Surface and System Loads § 23.395 Control system loads. (a) Each flight control system and its supporting structure must...

  10. Performance of the LAGUNA pulsed power system

    SciTech Connect

    Goforth, J.H.; Caird, R.S.; Fowler, C.M.; Greene, A.E.; Kruse, H.W.; Lindemuth, I.R.; Oona, H.; Reinovsky, R.E.

    1987-01-01

    The goal of the LAGUNA experimental series of the Los Alamos National Laboratory TRAILMASTER program is to accelerate an annular aluminum plasma z-pinch to greater than one hundred kilojoules of implosion kinetic energy. To accomplish this, an electrical pulse >5.5 MA must be delivered to a 20 nH load in approx.1 ..mu..s. The pulsed power system for these experiments consists of a capacitor bank for initial energy storage, a helical explosive-driven magnetic-flux compression generator for the prime power supply and opening and closing switches for power conditioning. While we have not yet achieved our design goal of 15 MA delivered to the inductive store of the system, all major components have functioned successfully at the 10 MA level. Significant successes and some difficulties experienced in these experiments are described.

  11. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  12. Energy loss analysis of an integrated space power distribution system

    NASA Technical Reports Server (NTRS)

    Kankam, M. D.; Ribeiro, P. F.

    1992-01-01

    The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

  13. Coordinated power control of unified power flow controller and its application for enhancing dynamic power system performance

    NASA Astrophysics Data System (ADS)

    Fang, Wanliang

    This thesis focuses on reporting my research study on a problem area relating to use of Unified Power Flow Controller (UPFC) for coordinating load flow in power systems so as to enhance their static and dynamic performance by having more secure and economical operation and higher dynamic stability margin. UPFC is considered as one of the most promising devices for implementing the Flexible AC Transmission System (FACTS) concept. Although development of UPFC is still on an infant stage, probing into its impact on power system operation is actively pursued and significant effort has been devoted to put it forward as a practical FACTS device and as a challenging academic research object. In order to consider UPFC as a basic power system element, it has to be involved in associated load flow computation essentially for power system control analysis and operational planning. An up front problem for design engineers is therefore pointing to a need to modify existing load flow program so as to accommodate interactions of UPFCs. A lot of research output start coming out but their computational efficiency are not high enough. In this regard, I propose two methods to perform the UPFC embedded load flow calculation to cater for two different types of application. The first one caters for analyzing direct control of load flow on transmission lines with embedded UPFCs. In this type of problem, active and reactive power of the lines, as well as the magnitude of bus voltages are priori given. The load flow solution can then be obtained and enables the UPFC parameters to be determined with a significantly improved computational efficiency. The second one works in contrary to the first one by which parameters of UPFCs are given before hand and the load flow calculation is performed for conforming a feasible operation. It can be regarded as an indirect load flow control calculation which is useful in planning stage for incorporating UPFC into existing system and/or carrying out

  14. Large lead/acid batteries for frequency regulation, load levelling and solar power applications

    NASA Astrophysics Data System (ADS)

    Wagner, R.

    Lead/acid batteries are suitable for a multitude of utility applications. This paper presents some examples where large lead/acid batteries have been used for frequency regulation, load levelling and solar power applications. The operational experiences are given together with a discussion about the design and technical specialities of these batteries. In 1986, a 17 MW/14 MWh battery was installed at BEWAG in Berlin which, at that time, was the largest lead/acid battery in the world. Designed to strengthen Berlin's 'island' system, it was used since the beginning of 1987 for frequency regulation and spinning reserve. In December 1993, when Berlin was connected to the electricity grid, frequency regulation was no longer required but the battery was still used for spinning reserve. For many years, the industrial battery plant of Hagen in Soest has used a large lead/acid battery for load levelling. The experience gained during more than ten years shows that load levelling and peak shaving can be a marked benefit for customers and utilities with regard to reducing their peak demand. In the summer of 1992, a 216 V and 2200 Ah lead/acid battery with positive tubular plates and gelled electrolyte was installed at a solar power plant in Flanitzhutte, a small village in the south of Germany which is not connected to the electricity grid. A report is given of the first years of use and includes a discussion about the best charge strategy for such gel batteries when used for solar power applications.

  15. Power law scaling in synchronization of brain signals depends on cognitive load.

    PubMed

    Tinker, Jesse; Velazquez, Jose Luis Perez

    2014-01-01

    As it has several features that optimize information processing, it has been proposed that criticality governs the dynamics of nervous system activity. Indications of such dynamics have been reported for a variety of in vitro and in vivo recordings, ranging from in vitro slice electrophysiology to human functional magnetic resonance imaging. However, there still remains considerable debate as to whether the brain actually operates close to criticality or in another governing state such as stochastic or oscillatory dynamics. A tool used to investigate the criticality of nervous system data is the inspection of power-law distributions. Although the findings are controversial, such power-law scaling has been found in different types of recordings. Here, we studied whether there is a power law scaling in the distribution of the phase synchronization derived from magnetoencephalographic recordings during executive function tasks performed by children with and without autism. Characterizing the brain dynamics that is different between autistic and non-autistic individuals is important in order to find differences that could either aid diagnosis or provide insights as to possible therapeutic interventions in autism. We report in this study that power law scaling in the distributions of a phase synchrony index is not very common and its frequency of occurrence is similar in the control and the autism group. In addition, power law scaling tends to diminish with increased cognitive load (difficulty or engagement in the task). There were indications of changes in the probability distribution functions for the phase synchrony that were associated with a transition from power law scaling to lack of power law (or vice versa), which suggests the presence of phenomenological bifurcations in brain dynamics associated with cognitive load. Hence, brain dynamics may fluctuate between criticality and other regimes depending upon context and behaviors.

  16. Scaling of advanced power systems

    NASA Astrophysics Data System (ADS)

    Wiley, Robert L.

    1991-12-01

    Parts of a study conducted to examine state-of-the-art power systems applicable to future military spacecraft are summarized. The study focused on burst-mode megawatt-class CW power, such as might be applied to SDIO directed energy systems, but lower-power, continuous-duty subsystems were included in less detail. A set of simple mass and volume algorithms has been developed to approximate several prime systems, and these were incorporated into a Lotus 1-2-3 spreadsheet. Among the power subsystems included in that study were primary batteries, alkaline primary fuel cells, and combustion turbogenerators. These systems, which are the most likely candidates for mobile battlefield power, are described in this paper.

  17. Space power systems technology

    NASA Astrophysics Data System (ADS)

    Coulman, George A.

    1994-03-01

    Reported here is a series of studies which examine several potential catalysts and electrodes for some fuel cell systems, some materials for space applications, and mathematical modeling and performance predictions for some solid oxide fuel cells and electrolyzers. The fuel cell systems have a potential for terrestrial applications in addition to solar energy conversion in space applications. Catalysts and electrodes for phosphoric acid fuel cell systems and for polymer electrolyte membrane (PEM) fuel cell and electrolyzer systems were examined.

  18. Space power systems technology

    NASA Technical Reports Server (NTRS)

    Coulman, George A.

    1994-01-01

    Reported here is a series of studies which examine several potential catalysts and electrodes for some fuel cell systems, some materials for space applications, and mathematical modeling and performance predictions for some solid oxide fuel cells and electrolyzers. The fuel cell systems have a potential for terrestrial applications in addition to solar energy conversion in space applications. Catalysts and electrodes for phosphoric acid fuel cell systems and for polymer electrolyte membrane (PEM) fuel cell and electrolyzer systems were examined.

  19. Control performance standards based load-frequency controller considering redox flow batteries coordinate with interline power flow controller

    NASA Astrophysics Data System (ADS)

    Chidambaram, I. A.; Paramasivam, B.

    2012-12-01

    This paper proposes a sophisticate application of redox flow batteries (RFB) coordinate with Interline Power Flow Controller (IPFC) for the improvement of Load Frequency Control (LFC) of a multiple units two- area power system. The Interline Power Flow Controller is to stabilize the frequency oscillations of the inter-area mode in the interconnected power system by the dynamic control of tie-line power flow. The redox flow batteries, which are not aged to the frequent charging and discharging, have a quick response and outstanding function during overload conditions. In addition to leveling load, the battery is advantageous for secondary control in the power system and maintenance of power quality of distributes power resources. The Bacterial Foraging Optimization (BFO) algorithm is use to optimize the parameters of the cost functions for designing the integral controller. Compliance with North American Electric Reliability Council (NERC) standards for Load Frequency Control has also been establishes in this work. Simulation studies reveal that the RFB coordinate with IPFC units has greater potential for improving the system dynamic performance.

  20. Transient and steady-state tests of the space power research engine with resistive and motor loads

    NASA Astrophysics Data System (ADS)

    Rauch, Jeffrey S.; Kankam, M. David

    1995-01-01

    The NASA Lewis Research Center (LeRC) has been testing free-piston Stirling engine/linear alternators (FPSE/LA) to develop advanced power convertors for space-based electrical power generation. Tests reported herein were performed to evaluate the interaction and transient behavior of FPSE/LA-based power systems with typical user loads. Both resistive and small induction motor loads were tested with the space power research engine (SPRE) power system. Tests showed that the control system could maintain constant long term voltage and stable periodic operation over a large range of engine operating parameters and loads. Modest resistive load changes were shown to cause relatively large voltage and, therefore, piston and displacer amplitude excursions. Starting a typical small induction motor was shown to cause large and, in some cases, deleterious voltage transients. The tests identified the need for more effective controls, if FPSE/LAs are to be used for stand-alone power systems. The tests also generated a large body of transient dynamic data useful for analysis code validation.

  1. Transient and Steady-state Tests of the Space Power Research Engine with Resistive and Motor Loads

    NASA Technical Reports Server (NTRS)

    Rauch, Jeffrey S.; Kankam, M. David

    1995-01-01

    The NASA Lewis Research Center (LeRC) has been testing free-piston Stirling engine/linear alternators (FPSE/LA) to develop advanced power convertors for space-based electrical power generation. Tests reported herein were performed to evaluate the interaction and transient behavior of FPSE/LA-based power systems with typical user loads. Both resistive and small induction motor loads were tested with the space power research engine (SPRE) power system. Tests showed that the control system could maintain constant long term voltage and stable periodic operation over a large range of engine operating parameters and loads. Modest resistive load changes were shown to cause relatively large voltage and, therefore, piston and displacer amplitude excursions. Starting a typical small induction motor was shown to cause large and, in some cases, deleterious voltage transients. The tests identified the need for more effective controls, if FPSE/LAs are to be used for stand-alone power systems. The tests also generated a large body of transient dynamic data useful for analysis code validation.

  2. Long Endurance Underwater Power System

    DTIC Science & Technology

    1989-08-04

    report, it was determined that the Alwatt at 6000 m will have a starting voltage of around 0.22 volts. However, at 0.22 volts and 0.15 A-hr/g of Al, 14.7... determined that the Alwatt would produce 2.3 W. Based on the assumption that the Alwatt power would be used for the various hotel loads, 1.15 W or 50% of the...Consumpdon rate 1.93E..04 Qh mA3/s Hydrogen consumption rate 8.40E.02 P/wden W/kg Gravimetric Power density 2.OOE+02 P/vden WlmA3 Volumetric Power density

  3. The Meteosat Second Generation (MSG) power system

    SciTech Connect

    Haines, J.E.; Levins, D.; Robben, A.; Sepers, A.

    1997-12-31

    Under the direction of the European Meteorological Satellite Organization (EUMETSAT) and the European Space Agency (ESA), space industries within Europe are in the process of developing a new series of larger and more performant geostationary weather satellites. The initial three spacecraft within this new series, which are known by the name of Meteosat Second Generation (MSG), are due to be progressively launched from the year 2000 onwards. The major objective of this mission is the continuation of the European weather watch and space borne atmospheric sensing services provided by the present series of Meteosat spacecraft. To satisfy this mission requirement, the payload compliment to be supported by MSG will consist of a comprehensive earth viewing instrument capable of operating in both the infra-red and visible spectrum, an earth radiation measurement system and a search and rescue facility. In furnishing the power needs for these payloads, the power generating element on the spin stabilized MSG spacecraft consists of a body mounted solar array, capable of providing 628 watts of electrical power at the end of seven years of geosynchronous orbital lifetime. The energy storage elements for the spacecraft consists of two, 29 ampere-hour batteries, while centralized power management is achieved by the Power Control Unit (PCU), which satisfies the payload and battery re-charge demands by controlling the available solar array power. Power distribution for the spacecraft electrical loads and heaters is achieved by the Power Distribution Unit (PDU) and for the pyrotechnic devices by the Pyrotechnic Release Unit.

  4. Power system restoration planning

    SciTech Connect

    Adibi, M.M. ); Fink, L.H.

    1994-02-01

    System restoration, as an extraordinary mode of system operation, requires careful planning and operator training. The generic tasks of restoration include determination of system and equipment status, preparation of plants and network for systematic restoration, reenergization of the network, and system rebuilding. The procedures for developing an effective restoration plan include formation of a qualified planning team, review of relevant system characteristics, formulation of assumptions regarding blackout scenarios, agreement on restoration goals, development of strategy and tactics, validation of the plan, training, and documentation.

  5. Advanced radiator systems for space power

    NASA Technical Reports Server (NTRS)

    Mattick, A. T.; Hertzberg, A.

    1987-01-01

    Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

  6. Electrical power system WP-04

    NASA Technical Reports Server (NTRS)

    Nored, Donald L.

    1990-01-01

    Viewgraphs on Space Station Freedom Electrical Power System (EPS) WP-40 are presented. Topics covered include: key EPS technical requirements; photovoltaic power module systems; solar array assembly; blanket containment box and box positioning subassemblies; solar cell; bypass diode assembly; Kapton with atomic oxygen resistant coating; sequential shunt unit; gimbal assembly; energy storage subsystem; thermal control subsystem; direct current switching unit; integrated equipment assembly; PV cargo element; PMAD system; and PMC and AC architecture.

  7. System performance predictions for Space Station Freedom's electric power system

    NASA Technical Reports Server (NTRS)

    Kerslake, Thomas W.; Hojnicki, Jeffrey S.; Green, Robert D.; Follo, Jeffrey C.

    1993-01-01

    Space Station Freedom Electric Power System (EPS) capability to effectively deliver power to housekeeping and user loads continues to strongly influence Freedom's design and planned approaches for assembly and operations. The EPS design consists of silicon photovoltaic (PV) arrays, nickel-hydrogen batteries, and direct current power management and distribution hardware and cabling. To properly characterize the inherent EPS design capability, detailed system performance analyses must be performed for early stages as well as for the fully assembled station up to 15 years after beginning of life. Such analyses were repeatedly performed using the FORTRAN code SPACE (Station Power Analysis for Capability Evaluation) developed at the NASA Lewis Research Center over a 10-year period. SPACE combines orbital mechanics routines, station orientation/pointing routines, PV array and battery performance models, and a distribution system load-flow analysis to predict EPS performance. Time-dependent, performance degradation, low earth orbit environmental interactions, and EPS architecture build-up are incorporated in SPACE. Results from two typical SPACE analytical cases are presented: (1) an electric load driven case and (2) a maximum EPS capability case.

  8. Optimal Load and Power Spectrum During Jerk and Back Jerk in Competitive Weightlifters.

    PubMed

    Flores, Francisco Javier; Sedano, Silvia; Redondo, Juan C

    2017-03-01

    Flores, FJ, Sedano, S, and Redondo, JC. Optimal load and power spectrum during jerk and back jerk in competitive weightlifters. J Strength Cond Res 31(3): 809-816, 2017-Although the ability to develop high levels of power is considered as a key component of success in many sporting activities, the optimal load (Pmax load) that maximizes power output (Pmax) remains controversial mainly during weightlifting movements. The aim of the present study was to determine Pmax load and optimal power spectrum (OPS) required to elicit Pmax by comparing jerk and back jerk exercises in competitive weightlifters. Thirteen male competitive weightlifters participated in 2 testing sessions. The first session involved performing one repetition maximum (1RM) in the back jerk and jerk and the second session assessed a power test across a spectrum of loads (30-90%) of each subject's 1RM in the predetermined exercises tested. Relative load had a significant effect on peak power, with Pmax load being obtained at 90% of the subjects' 1RM in both exercises assessed. There was no significant difference between the power outputs at 80% of 1RM compared with 90% of 1RM. Furthermore, Pmax load and OPS were the same for jerk and back jerk, whereas peak power in the back jerk demonstrated no significant increases in every load of the power-load curve. We can conclude that it may be advantageous to use loads equivalent to 80-90% of the 1RM in jerk and back jerk in competitive weightlifters when training to maximize power.

  9. Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power

    NASA Technical Reports Server (NTRS)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason R.; Nash, Roxanne E.; Sinka, Joseph; Bloomberg, Jacob J.

    2009-01-01

    Maximal power output occurs when subjects perform ballistic exercises using loads of 30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of

  10. Load-dependent regulation of neuromuscular system

    NASA Technical Reports Server (NTRS)

    Ohira, Yoshinobu; Kawano, Fuminori; Stevens, James L.; Wang, Xiao D.; Ishihara, Akihiko

    2004-01-01

    Roles of gravitational loading, sarcomere length, and/or tension development on the electromyogram (EMG) of soleus and afferent neurogram recorded at the L5 segmental level of spinal cord were investigated during parabolic flight of a jet airplane or hindlimb suspension in conscious rats. Both EMG and neurogram levels were increased when the gravity levels were elevated from 1-G to 2-G during the parabolic flight. They were decreased when the hindlimbs were unloaded by exposure to actual microgravity or by suspension. These phenomena were related to passive shortening of muscle fibers and/or sarcomeres. Unloading-related decrease in sarcomere length was greater at the central rather than the proximal and distal regions of fibers. These activities and tension development were not detected when the mean sarcomere length was less than 2.03 micrometers. It is suggested that load-dependent regulation of neuromuscular system is related to the tension development which is influenced by sarcomere length.

  11. Load-dependent regulation of neuromuscular system

    NASA Technical Reports Server (NTRS)

    Ohira, Yoshinobu; Kawano, Fuminori; Stevens, James L.; Wang, Xiao D.; Ishihara, Akihiko

    2004-01-01

    Roles of gravitational loading, sarcomere length, and/or tension development on the electromyogram (EMG) of soleus and afferent neurogram recorded at the L5 segmental level of spinal cord were investigated during parabolic flight of a jet airplane or hindlimb suspension in conscious rats. Both EMG and neurogram levels were increased when the gravity levels were elevated from 1-G to 2-G during the parabolic flight. They were decreased when the hindlimbs were unloaded by exposure to actual microgravity or by suspension. These phenomena were related to passive shortening of muscle fibers and/or sarcomeres. Unloading-related decrease in sarcomere length was greater at the central rather than the proximal and distal regions of fibers. These activities and tension development were not detected when the mean sarcomere length was less than 2.03 micrometers. It is suggested that load-dependent regulation of neuromuscular system is related to the tension development which is influenced by sarcomere length.

  12. Power generation systems and methods

    NASA Technical Reports Server (NTRS)

    Jones, Jack A. (Inventor); Chao, Yi (Inventor)

    2011-01-01

    A power generation system includes a plurality of submerged mechanical devices. Each device includes a pump that can be powered, in operation, by mechanical energy to output a pressurized output liquid flow in a conduit. Main output conduits are connected with the device conduits to combine pressurized output flows output from the submerged mechanical devices into a lower number of pressurized flows. These flows are delivered to a location remote of the submerged mechanical devices for power generation.

  13. Power systems for future missions

    NASA Technical Reports Server (NTRS)

    Gill, S. P.; Frye, P. E.; Littman, Franklin D.; Meisl, C. J.

    1994-01-01

    A comprehensive scenario of future missions was developed and applicability of different power technologies to these missions was assessed. Detailed technology development roadmaps for selected power technologies were generated. A simple methodology to evaluate economic benefits of current and future power system technologies by comparing Life Cycle Costs of potential missions was developed. The methodology was demonstrated by comparing Life Cycle Costs for different implementation strategies of DIPS/CBC technology to a selected set of missions.

  14. Passive Microwave Power Distribution Systems.

    DTIC Science & Technology

    wavelength by switching a reciprocal latching ferrite phase shifter in the stub, in response to termination of microwave power from one of the feed tubes....A standby microwave transmitter power amplifier tube is switched into a microwave power distribution system for a phased array in microseconds when...after the switching is completed, the switching being accomplished by changing electrical length of a quarter-wavelength waveguide stub to one-half

  15. Power turbine ventilation system

    NASA Technical Reports Server (NTRS)

    Wakeman, Thomas G. (Inventor); Brown, Richard W. (Inventor)

    1991-01-01

    Air control mechanism within a power turbine section of a gas turbine engine. The power turbine section includes a rotor and at least one variable pitch propulsor blade. The propulsor blade is coupled to and extends radially outwardly of the rotor. A first annular fairing is rotatable with the propulsor blade and interposed between the propulsor blade and the rotor. A second fairing is located longitudinally adjacent to the first fairing. The first fairing and the second fairing are differentially rotatable. The air control mechanism includes a platform fixedly coupled to a radially inner end of the propulsor blade. The platform is generally positioned in a first opening and a first fairing. The platform and the first fairing define an outer space. In a first position corresponding with a first propulsor blade pitch, the platform is substantially conformal with the first fairing. In a second position corresponding with the second propulsor blade pitch, an edge portion of the platform is displaced radially outwardly from the first fairing. When the blades are in the second position and rotating about the engine axis, the displacement of the edge portion with respect to the first fairing allows air to flow from the outer space to the annular cavity.

  16. Intelligent Energy Management in a Two Power-Bus Vehicle System

    DTIC Science & Technology

    2011-08-09

    Dirty Bus Branch 28V Battery Permanent Magnetic DC Motor Field Controlled DC generator Load Clean Bus Branch 28V Battery Bus Bus 19 DISTRIBUTION...Motor Field Controlled DC generator DC Power Supply Electronic Load DC Power Supply (125V, 3A) Permanent Magnetic DC Motor Field Controlled DC generator...Battery Lithium Battery Load Electronic Load Clean Bus Branch Original System Demo System Hydraulic System Permanent DC Motor Alternator Field

  17. Research on Load Energy Efficiency of DC Power Supply

    NASA Astrophysics Data System (ADS)

    Yue, Qing; Sun, Yiwei; Li, Ke; Li, Mengyu

    Traditional distribution network based on AC current has severely suffered from low efficiency in actual application, especially when an increasing numbers of home appliances are technically rely on DC current. In this paper, the energy efficiency of DC distribution system was analysed by means of comparison with traditional AC system. Firstly four types of typical appliances were discussed in terms of energy efficiency, which are the server, air conditioner, laptop computer and lighting. And then Models were further built up to perform the case study of three familiar situations in modern life, namely a typical living apartment, an office building and a data center. Finally, the power efficiencies of the three buildings were sorted up for comparison and analysis.

  18. A method of power load forecasting based on PCA-BP neural network

    NASA Astrophysics Data System (ADS)

    Ling, Xiejin

    2017-04-01

    The prediction of the power load is a complicated, nonlinear and affected by many factors question. In this article, the author uses Principal Component Analysis (PCA) to filter specific numbers principal components at first. After that, BP neural network is applied to forecast short term power load by the principal components. The results finally show the method is accurate and reliable.

  19. An Advanced Buffet Load Alleviation System

    NASA Technical Reports Server (NTRS)

    Burnham, Jay K.; Pitt, Dale M.; White, Edward V.; Henderson, Douglas A.; Moses, Robert W.

    2001-01-01

    This paper describes the development of an advanced buffet load alleviation (BLA) system that utilizes distributed piezoelectric actuators in conjunction with an active rudder to reduce the structural dynamic response of the F/A-18 aircraft vertical tails to buffet loads. The BLA system was defined analytically with a detailed finite-element-model of the tail structure and piezoelectric actuators. Oscillatory aerodynamics were included along with a buffet forcing function to complete the aeroservoelastic model of the tail with rudder control surface. Two single-input-single-output (SISO) controllers were designed, one for the active rudder and one for the active piezoelectric actuators. The results from the analytical open and closed loop simulations were used to predict the system performance. The objective of this BLA system is to extend the life of vertical tail structures and decrease their life-cycle costs. This system can be applied to other aircraft designs to address suppression of structural vibrations on military and commercial aircraft.

  20. The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed

    NASA Astrophysics Data System (ADS)

    Kelley, Jay Paul

    As the Navy's demands for high power transient loads evolves, so too does the need for alternative energy sources to back-up the more traditional power generation. Such applications in need of support include electrical grid backup and directed energy weapon systems such as electromagnetic launchers, laser systems, and high power microwave generators, among others. Among the alternative generation sources receiving considerable attention are energy storage devices such as rechargeable electrochemical batteries and capacitors. In such applications as those mentioned above, these energy storage devices offer the ability to serve a dual role as both a power source to the various loads as well high power loads themselves to the continual generation when the high power transient loads are in periods of downtime. With the recent developments in electrochemical energy storage, lithium-ion batteries (LIBs) seem like the obvious choice, but previous research has shown that the elevated rates of charging can be detrimental to both the cycle life and the operational life span of the device. In order to preserve the batteries, their charge rate must be limited. One proposed method to accomplish the dual role task mentioned above, while preserving the life of the batteries, is by combining high energy density LIBs with high power density electric double layer capacitors (EDLCs) or lithium-ion capacitors (LICs) using controllable power electronics to adjust the flow of power to and from each device. Such a configuration is typically referred to as hybrid energy storage module (HESM). While shipboard generators start up, the combined high energy density and high power density of the HESM provides the capability to source critical loads for an extended period of time at the high rates they demand. Once the generator is operationally efficient, the HESM can act as a high energy reservoir to harvest the energy from the generator while the loads are in short periods of inactivity

  1. Phase change energy storage for solar dynamic power systems

    NASA Technical Reports Server (NTRS)

    Chiaramonte, F. P.; Taylor, J. D.

    1992-01-01

    This paper presents the results of a transient computer simulation that was developed to study phase change energy storage techniques for Space Station Freedom (SSF) solar dynamic (SD) power systems. Such SD systems may be used in future growth SSF configurations. Two solar dynamic options are considered in this paper: Brayton and Rankine. Model elements consist of a single node receiver and concentrator, and takes into account overall heat engine efficiency and power distribution characteristics. The simulation not only computes the energy stored in the receiver phase change material (PCM), but also the amount of the PCM required for various combinations of load demands and power system mission constraints. For a solar dynamic power system in low earth orbit, the amount of stored PCM energy is calculated by balancing the solar energy input and the energy consumed by the loads corrected by an overall system efficiency. The model assumes an average 75 kW SD power system load profile which is connected to user loads via dedicated power distribution channels. The model then calculates the stored energy in the receiver and subsequently estimates the quantity of PCM necessary to meet peaking and contingency requirements. The model can also be used to conduct trade studies on the performance of SD power systems using different storage materials.

  2. Phase change energy storage for solar dynamic power systems

    NASA Technical Reports Server (NTRS)

    Chiaramonte, F. P.; Taylor, J. D.

    1992-01-01

    This paper presents the results of a transient computer simulation that was developed to study phase change energy storage techniques for Space Station Freedom (SSF) solar dynamic (SD) power systems. Such SD systems may be used in future growth SSF configurations. Two solar dynamic options are considered in this paper: Brayton and Rankine. Model elements consist of a single node receiver and concentrator, and takes into account overall heat engine efficiency and power distribution characteristics. The simulation not only computes the energy stored in the receiver phase change material (PCM), but also the amount of the PCM required for various combinations of load demands and power system mission constraints. For a solar dynamic power system in low earth orbit, the amount of stored PCM energy is calculated by balancing the solar energy input and the energy consumed by the loads corrected by an overall system efficiency. The model assumes an average 75 kW SD power system load profile which is connected to user loads via dedicated power distribution channels. The model then calculates the stored energy in the receiver and subsequently estimates the quantity of PCM necessary to meet peaking and contingency requirements. The model can also be used to conduct trade studies on the performance of SD power systems using different storage materials.

  3. Appropriate Loads for Peak-Power During Resisted Sprinting on a Non-Motorized Treadmill

    PubMed Central

    Andre, Matthew J.; Fry, Andrew C.; Lane, Michael T.

    2013-01-01

    The purpose of this study was to determine the load which allows the highest peak power for resisted sprinting on a non-motorized treadmill and to determine if other variables are related to individual differences. Thirty college students were tested for vertical jump, vertical jump peak and mean power, 10 m sprint, 20 m sprint, leg press 1 RM, leg press 1 RM relative to body weight, leg press 1 RM relative to lean body mass, leg press 1 RM power, and leg press power at 80% of 1 RM. Participants performed eight resisted sprints on a non-motorized treadmill, with increasing relative loads expressed as percent of body weight. Sprint peak power was measured for each load. Pearson correlations were used to determine if relationships between the sprint peak power load and the other variables were significant. The sprint peak power load had a mode of 35% with 73% of all participants having a relative sprint peak power load between 25–35%. Significant correlations occurred between sprint peak power load and body weight, lean body mass, vertical jump peak and mean power, leg press 1 RM, leg press 1 RM relative to lean body mass, leg press 1 RM power, and leg press power at 80% of 1 RM (r = 0.44, 0.43, 0.39, 0.37, 0.47, 0.39, 0.46, and 0.47, respectively). Larger, stronger, more powerful athletes produced peak power at a higher relative load during resisted sprinting on a non-motorized treadmill. PMID:24233103

  4. Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system: system load following capability

    SciTech Connect

    Lessard, R.D.; Blecher, W.A.; Merrick, D.

    1981-09-01

    The load-following capability of fluidized bed combustion-augmented compressed air energy storage systems was evaluated. The results are presented in two parts. The first part is an Executive Summary which provides a concise overview of all major elements of the study including the conclusions, and, second, a detailed technical report describing the part-load and load following capability of both the pressurized fluid bed combustor and the entire pressurized fluid bed combustor/compressed air energy storage system. The specific tasks in this investigation were to: define the steady-state, part-load operation of the CAES open-bed PFBC; estimate the steady-state, part-load performance of the PFBC/CAES system and evaluate any possible operational constraints; simulate the performance of the PFBC/CAES system during transient operation and assess the load following capability of the system; and establish a start-up procedure for the open-bed PFBC and evaluate the impact of this procedure. The conclusions are encouraging and indicate that the open-bed PFBC/CAES power plant should provide good part-load and transient performance, and should have no major equipment-related constraints, specifically, no major problems associated with the performance or design of either the open-end PFBC or the PFBC/CAES power plant in steady-state, part-load operation are envisioned. The open-bed PFBC/CAES power plant would have a load following capability which would be responsive to electric utility requirements for a peak-load power plant. The open-bed PFBC could be brought to full operating conditions within 15 min after routine shutdown, by employing a hot-start mode of operation. The PFBC/CAES system would be capable of rapid changes in output power (12% of design load per minute) over a wide output power range (25% to 100% of design output). (LCL)

  5. Modeling a constant power load for nickel-hydrogen battery testing using SPICE

    NASA Technical Reports Server (NTRS)

    Bearden, Douglas B.; Lollar, Louis F.; Nelms, R. M.

    1990-01-01

    The effort to design and model a constant power load for the HST (Hubble Space Telescope) nickel-hydrogen battery tests is described. The constant power load was designed for three different simulations on the batteries: life cycling, reconditioning, and capacity testing. A dc-dc boost converter was designed to act as this constant power load. A boost converter design was chosen because of the low test battery voltage (4 to 6 VDC) generated and the relatively high power requirement of 60 to 70 W. The SPICE model was shown to consistently predict variations in the actual circuit as various designs were attempted. It is concluded that the confidence established in the SPICE model of the constant power load ensures its extensive utilization in future efforts to improve performance in the actual load circuit.

  6. Economic Evaluation of Space Solar Power System

    NASA Astrophysics Data System (ADS)

    Matsuoka, L.

    2004-12-01

    In this paper, we evaluate the value that the solar panels will be set on the orbit from the economic standpoint and consider the necessity of the Space Solar Power System (SSPS). In order to these evaluations, we compare the SSPS with the photovoltaic power system on the ground (PVPSG). Firstly, we examined the generation cost of the PVPSG. When the PVPSG do not have some storage system and can not supply the electricity for the base-load power, the cost of generating power calculated is about 8.1 yen/kWh in the minimum cost cases, the cost of the equipments around the solar cell is the predictive values. The SSPS is expensive slightly than it of the PVPSG in this future scenario. Secondary, we suppose the case that the PVPSG have to have some storage system in order that the PVPSG need to send the electricity stably. The pumped hydropower, the lead battery and the fuel cell are assumed as the storages in this paper. In these cases, the costs of generating power become expensive over 30 yen/kWh. It is possible that the SSPS is not expensive than it with some cost reductions about the transportation cost to the earth orbit.

  7. A Systems Model for Power Technology Assessment

    NASA Technical Reports Server (NTRS)

    Hoffman, David J.

    2002-01-01

    A computer model is under continuing development at NASA Glenn Research Center that enables first-order assessments of space power technology. The model, an evolution of NASA Glenn's Array Design Assessment Model (ADAM), is an Excel workbook that consists of numerous spreadsheets containing power technology performance data and sizing algorithms. Underlying the model is a number of databases that contain default values for various power generation, energy storage and power management and distribution component parameters. These databases are actively maintained by a team of systems analysts so that they contain state-of-art data as well as the most recent technology performance projections. Sizing of the power subsystems can be accomplished either by using an assumed mass specific power (W/kg) or energy (Wh/kg) or by a bottoms-up calculation that accounts for individual component performance and masses. The power generation, energy storage and power management and distribution subsystems are sized for given mission requirements for a baseline case and up to three alternatives. This allows four different power systems to be sized and compared using consistent assumptions and sizing algorithms. The component sizing models contained in the workbook are modular so that they can be easily maintained and updated. All significant input values have default values loaded from the databases that can be over-written by the user. The default data and sizing algorithms for each of the power subsystems are described in some detail. The user interface and workbook navigational features are also discussed. Finally, an example study case that illustrates the model's capability is presented.

  8. Powerful Midwest Storm System

    NASA Image and Video Library

    This animation of imagery from NOAA’s GOES-13 satellite shows themovement of storm systems in the south central United States on May 20,2013. Warm, moist gulf air flowing across Texas, Oklahoma...

  9. Fault diagnosis of power systems

    SciTech Connect

    Sekine, Y. ); Akimoto, Y. ); Kunugi, M. )

    1992-05-01

    Fault diagnosis of power systems plays a crucial role in power system monitoring and control that ensures stable supply of electrical power to consumers. In the case of multiple faults or incorrect operation of protective devices, fault diagnosis requires judgment of complex conditions at various levels. For this reason, research into application of knowledge-based systems go an early start and reports of such systems have appeared in may papers. In this paper, these systems are classified by the method of inference utilized in the knowledge-based systems for fault diagnosis of power systems. The characteristics of each class and corresponding issues as well as the state-of-the-art techniques for improving their performance are presented. Additional topics covered are user interfaces, interfaces with energy management systems (EMS's), and expert system development tools for fault diagnosis. Results and evaluation of actual operation in the field are also discussed. Knowledge-based fault diagnosis of power systems will continue to disseminate.

  10. Water Powered Bioassay System

    DTIC Science & Technology

    2004-06-01

    capillary micropump 27 Figure 30: Slow dripping/separation of a droplet from a capillary 4.1.5 Micro Osmotic Pumping Nano Droplet...stored and delivered fluidic pressure and, with a combination of pumps and valves, formed the basic micro fluidic processing unit. The addition of...System, Microvalve, Micro -Accumulator, Micro Dialysis Needle, Bioassay System, Water Activated, Micro Osmotic Pump 16. PRICE CODE 17. SECURITY

  11. Constant Power Allocation Methods for SC-FDMA Systems

    NASA Astrophysics Data System (ADS)

    Pao, Wei-Cheng; Chen, Yung-Fang; Chang, Dah-Chung

    A simple suboptimal power allocation method is proposed for SC-FDMA systems. It is known that the performance of constant power-based allocation methods is close to that of optimal solutions. In this letter, by utilizing the waterfilling condition inequality derived for SC-FDMA systems, a threshold is set to select subcarriers for loading constant power to these selected subcarriers. It offers competitive performance as confirmed by the simulation results.

  12. Digital data processing system dynamic loading analysis

    NASA Technical Reports Server (NTRS)

    Lagas, J. J.; Peterka, J. J.; Tucker, A. E.

    1976-01-01

    Simulation and analysis of the Space Shuttle Orbiter Digital Data Processing System (DDPS) are reported. The mated flight and postseparation flight phases of the space shuttle's approach and landing test configuration were modeled utilizing the Information Management System Interpretative Model (IMSIM) in a computerized simulation modeling of the ALT hardware, software, and workload. System requirements simulated for the ALT configuration were defined. Sensitivity analyses determined areas of potential data flow problems in DDPS operation. Based on the defined system requirements and the sensitivity analyses, a test design is described for adapting, parameterizing, and executing the IMSIM. Varying load and stress conditions for the model execution are given. The analyses of the computer simulation runs were documented as results, conclusions, and recommendations for DDPS improvements.

  13. Power enhanced frequency conversion system

    NASA Technical Reports Server (NTRS)

    Sanders, Steven (Inventor); Lang, Robert J. (Inventor); Waarts, Robert G. (Inventor)

    2001-01-01

    A frequency conversion system includes at least one source providing a first near-IR wavelength output including a gain medium for providing high power amplification, such as double clad fiber amplifier, a double clad fiber laser or a semiconductor tapered amplifier to enhance the power output level of the near-IR wavelength output. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Ra-man/Brillouin amplifier or oscillator between the high power source and the NFM device.

  14. Cryogenic Systems and Superconductive Power

    DTIC Science & Technology

    subsystem suitable for providing reliable long-lived cryogenic refrigeration for a superconductive ship propulsion system; and, Provide a sound...technical basis for subsequent applications of superconductive power in the area of ship propulsion .

  15. Probability problems in seismic risk analysis and load combinations for nuclear power plants

    SciTech Connect

    George, L.L.

    1983-01-01

    This workshop describes some probability problems in power plant reliability and maintenance analysis. The problems are seismic risk analysis, loss of load probability, load combinations, and load sharing. The seismic risk problem is to compute power plant reliability given an earthquake and the resulting risk. Component survival occurs if its peak random response to the earthquake does not exceed its strength. Power plant survival is a complicated Boolean function of component failures and survivals. The responses and strengths of components are dependent random processes, and the peak responses are maxima of random processes. The resulting risk is the expected cost of power plant failure.

  16. Interconnection of a photovoltaic power generation system with the grid

    NASA Astrophysics Data System (ADS)

    Corbefin, R.; Vacelet, G.

    Converting photovoltaic system-generated power into a form compatible with grid-furnished power and simultaneously ensuring that maximal power is drawn from the solar system is discussed. A converter is interposed between the solar-derived electricity and the grid lines, allowing the user to apply the power to a load, feed excess power to the grid, and receive power from the grid when the photovoltaic output is too low to fill demand. A dc-ac converter is described, with microprocessor controlled transistorized switching to adapt the solar output to the load amplitude on demand, while maintaining constant voltage. An adaptor allows the converter to take its amplitude, phase, and frequency regulation from the grid, and also assures that power will flow only toward the grid.

  17. GCLAS: a graphical constituent loading analysis system

    USGS Publications Warehouse

    McKallip, T.E.; Koltun, G.F.; Gray, J.R.; Glysson, G.D.

    2001-01-01

    The U. S. Geological Survey has developed a program called GCLAS (Graphical Constituent Loading Analysis System) to aid in the computation of daily constituent loads transported in stream flow. Due to the relative paucity with which most water-quality data are collected, computation of daily constituent loads is moderately to highly dependent on human interpretation of the relation between stream hydraulics and constituent transport. GCLAS provides a visual environment for evaluating the relation between hydraulic and other covariate time series and the constituent chemograph. GCLAS replaces the computer program Sedcalc, which is the most recent USGS sanctioned tool for constructing sediment chemographs and computing suspended-sediment loads. Written in a portable language, GCLAS has an interactive graphical interface that permits easy entry of estimated values and provides new tools to aid in making those estimates. The use of a portable language for program development imparts a degree of computer platform independence that was difficult to obtain in the past, making implementation more straightforward within the USGS' s diverse computing environment. Some of the improvements introduced in GCLAS include (1) the ability to directly handle periods of zero or reverse flow, (2) the ability to analyze and apply coefficient adjustments to concentrations as a function of time, streamflow, or both, (3) the ability to compute discharges of constituents other than suspended sediment, (4) the ability to easily view data related to the chemograph at different levels of detail, and (5) the ability to readily display covariate time series data to provide enhanced visual cues for drawing the constituent chemograph.

  18. Power Systems Advanced Research

    SciTech Connect

    California Institute of Technology

    2007-03-31

    In the 17 quarters of the project, we have accomplished the following milestones - first, construction of the three multiwavelength laser scattering machines for different light scattering study purposes; second, build up of simulation software package for simulation of field and laboratory particulates matters data; third, carried out field online test on exhaust from combustion engines with our laser scatter system. This report gives a summary of the results and achievements during the project's 16 quarters period. During the 16 quarters of this project, we constructed three multiwavelength scattering instruments for PM2.5 particulates. We build up a simulation software package that could automate the simulation of light scattering for different combinations of particulate matters. At the field test site with our partner, Alturdyne, Inc., we collected light scattering data for a small gas turbine engine. We also included the experimental data feedback function to the simulation software to match simulation with real field data. The PM scattering instruments developed in this project involve the development of some core hardware technologies, including fast gated CCD system, accurately triggered Passively Q-Switched diode pumped lasers, and multiwavelength beam combination system. To calibrate the scattering results for liquid samples, we also developed the calibration system which includes liquid PM generator and size sorting instrument, i.e. MOUDI. In this report, we give the concise summary report on each of these subsystems development results.

  19. Design, construction and evaluation of two large photovoltaic power systems

    SciTech Connect

    Solman, F. J.; Nichols, B. E.

    1980-01-01

    A description and comparison of two large photovoltaic electric power systems is presented. The smaller system is designed for economic viability in the near future and provides 70 to 90 percent of the electric requirements for its prime load, a daytime AM radio station. The second system is a stand-alone power system suitable for a remote residential and light industrial community. No electric utility grid is present at this location so the management of a backup Diesel generator is also required.

  20. The ac power system testbed

    NASA Technical Reports Server (NTRS)

    Mildice, J.; Sundberg, R.

    1987-01-01

    The object of this program was to design, build, test, and deliver a high frequency (20 kHz) Power System Testbed which would electrically approximate a single, separable power channel of an IOC Space Station. That program is described, including the technical background, and the results are discussed showing that the major assumptions about the characteristics of this class of hardware (size, mass, efficiency, control, etc.) were substantially correct. This testbed equipment was completed and delivered and is being operated as part of the Space Station Power System Test Facility.

  1. The Effect of External Loading on Force and Power Production during Plyometric Push-ups.

    PubMed

    Hinshaw, Taylour J; Stephenson, Mitchell L; Sha, Zhanxin; Dai, Boyi

    2017-04-15

    One common exercise to train upper body strength and power is the push-up. Training at the loads that would produce the greatest power is an effective way to increase peak power. The purpose of the current study was to quantify the changes in peak force, peak power, and peak velocity among a modified plyometric push-up and plyometric push-ups with or without external loading in physically-active young adults. Eighteen male and seventeen female participants completed four push-ups: (1) modified plyometric push-up on the knees, (2) plyometric push-up without external loading, (3) plyometric push-up with an external load of 5% body weight, and (4) plyometric push-up with an external load of 10% body weight. Two force platforms were set up to collect vertical ground reaction forces at the hands and feet. The modified plyometric push-up demonstrated the lowest force, power, and velocity (5.4 ≥ Cohen's dz ≥ 1.2). Peak force and force at peak velocity increased (3.8 ≥ Cohen's dz ≥ 0.3) and peak velocity and velocity at peak power decreased (1.4 ≥ Cohen's dz ≥ 0.8) for the push-up without external loading compared with the two push-ups with external loading. No significant differences were observed for peak power among the push-ups with or without external loading (0.4 ≥ Cohen's dz ≥ 0.1). While peak power is similar with or without external loading, push-ups without external loading may be more beneficial for a quick movement, and push-ups with external loading may be more beneficial for a greater force production.

  2. Optimal loading range for the development of peak power output in the hexagonal barbell jump squat.

    PubMed

    Turner, Thomas S; Tobin, Daniel P; Delahunt, Eamonn

    2015-06-01

    Recent studies indicate that the utilization of the hexagonal barbell jump squat (HBJS) compared with the traditional barbell jump squat may offer a superior method of developing peak power. The notion that a single optimal load may be prescribed in training programs aiming to develop peak power is subject to debate. The purpose of this study was to identify the optimal load corresponding with peak power output during the HBJS in professional rugby union players. Seventeen professional rugby union players participated in this study. Participants performed 3 unloaded countermovement jumps on a force plate and 3 HBJS at each of the following randomized loads: 10, 20, 30, and 40% of box squat 1 repetition maximum (1RM). Peak power output was the dependent variable of interest. A one-way repeated measures analysis of variance was conducted to compare peak power output across each load. Peak power output was the dependent variable of interest. A significant main effect for load was observed (Wilk's Lambda = 0.11, F(4,13) = 18.07, p < 0.01, partial η2 = 0.88). Results of the Bonferroni-adjusted pairwise comparisons indicated that peak power output in the HBJS is optimized at a load range between 10 and 20% of box squat 1RM. The results of this study indicate that the use of the HBJS with a training load between 10 and 20% of box squat 1RM optimizes peak power output in professional rugby union players.

  3. Hydro power flexibility for power systems with variable renewable energy sources: an IEA Task 25 collaboration: Hydro power flexibility for power systems

    SciTech Connect

    Huertas-Hernando, Daniel; Farahmand, Hossein; Holttinen, Hannele; Kiviluoma, Juha; Rinne, Erkka; Söder, Lennart; Milligan, Michael; Ibanez, Eduardo; Martínez, Sergio Martín; Gomez-Lazaro, Emilio; Estanqueiro, Ana; Rodrigues, Luis; Carr, Luis; van Roon, Serafin; Orths, Antje Gesa; Eriksen, Peter Børre; Forcione, Alain; Menemenlis, Nickie

    2016-06-20

    Hydro power is one of the most flexible sources of electricity production. Power systems with considerable amounts of flexible hydro power potentially offer easier integration of variable generation, e.g., wind and solar. However, there exist operational constraints to ensure mid-/long-term security of supply while keeping river flows and reservoirs levels within permitted limits. In order to properly assess the effective available hydro power flexibility and its value for storage, a detailed assessment of hydro power is essential. Due to the inherent uncertainty of the weather-dependent hydrological cycle, regulation constraints on the hydro system, and uncertainty of internal load as well as variable generation (wind and solar), this assessment is complex. Hence, it requires proper modeling of all the underlying interactions between hydro power and the power system, with a large share of other variable renewables. A summary of existing experience of wind integration in hydro-dominated power systems clearly points to strict simulation methodologies. Recommendations include requirements for techno-economic models to correctly assess strategies for hydro power and pumped storage dispatch. These models are based not only on seasonal water inflow variations but also on variable generation, and all these are in time horizons from very short term up to multiple years, depending on the studied system. Another important recommendation is to include a geographically detailed description of hydro power systems, rivers' flows, and reservoirs as well as grid topology and congestion.

  4. Security Policies for Mitigating the Risk of Load Altering Attacks on Smart Grid Systems

    SciTech Connect

    Ryutov, Tatyana; AlMajali, Anas; Neuman, Clifford

    2015-04-01

    While demand response programs implement energy efficiency and power quality objectives, they bring potential security threats to the Smart Grid. The ability to influence load in a system enables attackers to cause system failures and impacts the quality and integrity of power delivered to customers. This paper presents a security mechanism to monitor and control load according to a set of security policies during normal system operation. The mechanism monitors, detects, and responds to load altering attacks. We examined the security requirements of Smart Grid stakeholders and constructed a set of load control policies enforced by the mechanism. We implemented a proof of concept prototype and tested it using the simulation environment. By enforcing the proposed policies in this prototype, the system is maintained in a safe state in the presence of load drop attacks.

  5. Design description of the Schuchuli Village photovoltaic power system

    NASA Technical Reports Server (NTRS)

    Ratajczak, A. F.; Vasicek, R. W.; Delombard, R.

    1981-01-01

    A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

  6. Design description of the Schuchuli Village photovoltaic power system

    NASA Astrophysics Data System (ADS)

    Ratajczak, A. F.; Vasicek, R. W.; Delombard, R.

    1981-05-01

    A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

  7. Simulating fast and slow dynamic effects in power systems

    SciTech Connect

    de Mello, F.P.; Feltes, J.W.; Laskowski, T.F.; Oppel, L.J. )

    1992-07-01

    Electric power systems comprise a nearly infinite number of devices, exhibiting dynamic characteristics in a wide range of bandwidths and with significant nonlinear effects. Historically, the nature of these devices, the robust configuration of the electric power system, and its loading were such that the interaction between devices became relatively unimportant in system performance several seconds after disturbances. Greater utilization of electric plant, through heavier system loadings, interconnections, and increasing use of controls, has at times necessitated predictions of system performance through simulation extending over a time range of tens of seconds to several minutes. The phenomena occurring over this extended time frame has been referred to as long-term dynamics. There are basically two classes of problems involving long-term dynamics. One is the problem of islanding with significant imbalances between load and generation where prime mover action in response to frequency deviations is significant. The other concerns problems of insufficient damping and/or synchronizing power, and voltage collapse.

  8. Application of Hybrid Optimization-Expert System for Optimal Power Management on Board Space Power Station

    NASA Technical Reports Server (NTRS)

    Momoh, James; Chattopadhyay, Deb; Basheer, Omar Ali AL

    1996-01-01

    The space power system has two sources of energy: photo-voltaic blankets and batteries. The optimal power management problem on-board has two broad operations: off-line power scheduling to determine the load allocation schedule of the next several hours based on the forecast of load and solar power availability. The nature of this study puts less emphasis on speed requirement for computation and more importance on the optimality of the solution. The second category problem, on-line power rescheduling, is needed in the event of occurrence of a contingency to optimally reschedule the loads to minimize the 'unused' or 'wasted' energy while keeping the priority on certain type of load and minimum disturbance of the original optimal schedule determined in the first-stage off-line study. The computational performance of the on-line 'rescheduler' is an important criterion and plays a critical role in the selection of the appropriate tool. The Howard University Center for Energy Systems and Control has developed a hybrid optimization-expert systems based power management program. The pre-scheduler has been developed using a non-linear multi-objective optimization technique called the Outer Approximation method and implemented using the General Algebraic Modeling System (GAMS). The optimization model has the capability of dealing with multiple conflicting objectives viz. maximizing energy utilization, minimizing the variation of load over a day, etc. and incorporates several complex interaction between the loads in a space system. The rescheduling is performed using an expert system developed in PROLOG which utilizes a rule-base for reallocation of the loads in an emergency condition viz. shortage of power due to solar array failure, increase of base load, addition of new activity, repetition of old activity etc. Both the modules handle decision making on battery charging and discharging and allocation of loads over a time-horizon of a day divided into intervals of 10

  9. Application of Hybrid Optimization-Expert System for Optimal Power Management on Board Space Power Station

    NASA Technical Reports Server (NTRS)

    Momoh, James; Chattopadhyay, Deb; Basheer, Omar Ali AL

    1996-01-01

    The space power system has two sources of energy: photo-voltaic blankets and batteries. The optimal power management problem on-board has two broad operations: off-line power scheduling to determine the load allocation schedule of the next several hours based on the forecast of load and solar power availability. The nature of this study puts less emphasis on speed requirement for computation and more importance on the optimality of the solution. The second category problem, on-line power rescheduling, is needed in the event of occurrence of a contingency to optimally reschedule the loads to minimize the 'unused' or 'wasted' energy while keeping the priority on certain type of load and minimum disturbance of the original optimal schedule determined in the first-stage off-line study. The computational performance of the on-line 'rescheduler' is an important criterion and plays a critical role in the selection of the appropriate tool. The Howard University Center for Energy Systems and Control has developed a hybrid optimization-expert systems based power management program. The pre-scheduler has been developed using a non-linear multi-objective optimization technique called the Outer Approximation method and implemented using the General Algebraic Modeling System (GAMS). The optimization model has the capability of dealing with multiple conflicting objectives viz. maximizing energy utilization, minimizing the variation of load over a day, etc. and incorporates several complex interaction between the loads in a space system. The rescheduling is performed using an expert system developed in PROLOG which utilizes a rule-base for reallocation of the loads in an emergency condition viz. shortage of power due to solar array failure, increase of base load, addition of new activity, repetition of old activity etc. Both the modules handle decision making on battery charging and discharging and allocation of loads over a time-horizon of a day divided into intervals of 10

  10. Elastic recoil can either amplify or attenuate muscle-tendon power, depending on inertial vs. fluid dynamic loading.

    PubMed

    Richards, Christopher T; Sawicki, Gregory S

    2012-11-21

    Frog jumps exceed muscle power limits. To achieve this, a muscle may store elastic energy in tendon before it is released rapidly, producing 'power amplification' as tendon recoil assists the muscle to accelerate the load. Do the musculoskeletal modifications conferring power amplification help or hinder frog swimming? We used a Hill-type mathematical model of a muscle-tendon (MT) with contractile element (CE) and series elastic element (SEE) properties of frogs. We varied limb masses from 0.3 to 30 g, foot-fin areas from 0.005 to 50 cm(2) and effective mechanical advantage (EMA=in-lever/out-lever) from 0.025 to 0.1. 'Optimal' conditions produced power amplification of ~19% greater than the CE limit. Yet, other conditions caused ~80% reduction of MT power (power attenuation) due to SEE recoil absorbing power from (rather than adding to) the CE. The tendency for elastic recoil to cause power amplification vs. attenuation was load dependent: low fluid drag loads, high limb mass and EMA=0.1 caused power amplification whereas high drag, low mass and low EMA (=0.025) caused attenuation. Power amplification emerged when: (1) CE shortening velocity is 1/3V(max), (2) elastic energy storage is neither too high nor too low, and (3). peak inertial-drag force ratio ≥ ~1.5. Excessive elastic energy storage delayed the timing of recoil, causing power attenuation. Thus our model predicts that for fluid loads, the benefit from a compliant tendon is modest, and when the system is 'poorly tuned' (i.e., inappropriate EMA), MT power attenuation can be severe. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Space Station power system issues

    NASA Technical Reports Server (NTRS)

    Giudici, R. J.

    1985-01-01

    Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite.

  12. Solar-Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  13. Solar-Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2001-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  14. Solar-Powered Refrigeration System

    NASA Technical Reports Server (NTRS)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  15. Solar-Powered Refrigeration System

    NASA Astrophysics Data System (ADS)

    Ewert, Michael K.; Bergeron, David J., III

    2002-10-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  16. Application of the mobility power flow approach to structural response from distributed loading

    NASA Technical Reports Server (NTRS)

    Cuschieri, J. M.

    1988-01-01

    The problem of the vibration power flow through coupled substructures when one of the substructures is subjected to a distributed load is addressed. In all the work performed thus far, point force excitation was considered. However, in the case of the excitation of an aircraft fuselage, distributed loading on the whole surface of a panel can be as important as the excitation from directly applied forces at defined locations on the structures. Thus using a mobility power flow approach, expressions are developed for the transmission of vibrational power between two coupled plate substructures in an L configuration, with one of the surfaces of one of the plate substructures being subjected to a distributed load. The types of distributed loads that are considered are a force load with an arbitrary function in space and a distributed load similar to that from acoustic excitation.

  17. Development of an analytical tool to study power quality of AC power systems for large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. Alan; Kankam, M. David

    1991-01-01

    A harmonic power flow program applicable to space power systems with sources of harmonic distortion is described. The algorithm is a modification of the Electric Power Research Institute's HARMFLO program which assumes a three phase, balanced, AC system with loads of harmonic distortion. The modified power flow program can be used with single phase, AC systems. Early results indicate that the required modifications and the models developed are quite adequate for the analysis of a 20 kHz testbed built by General Dynamics Corporation. This is demonstrated by the acceptable correlation of present results with published data. Although the results are not exact, the discrepancies are relatively small.

  18. Development of an analytical tool to study power quality of ac power systems for large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. A.; Kankam, M. D.

    1991-01-01

    A harmonic power flow program applicable to space power systems with sources of harmonic distortion is described. The algorithm is a modification of Electric Power Research Institute's HARMFLO program which assumes a three-phase, balanced, ac system with loads of harmonic distortion. The modified power flow program can be used with single phase, ac systems. Early results indicate that the required modifications and the models developed are quite adequate for the analysis of a 20-kHz testbed built by General Dynamics Corporation. This is demonstrated by the acceptable correlation of the present results with published data. Although the results are not exact, the discrepancies are relatively small.

  19. Conceptual definition of Automated Power Systems Management. [for planetary spacecraft

    NASA Technical Reports Server (NTRS)

    Imamura, M. S.; Skelly, L.; Weiner, H.

    1977-01-01

    Automated Power Systems Management (APSM) is defined as the capability of a spacecraft power system to automatically perform monitoring, computational, command, and control functions without ground intervention. Power systems for future planetary spacecraft must have this capability because they must perform up to 10 years, and accommodate real-time changes in mission execution autonomously. Specific APSM functions include fault detection, isolation, and correction; system performance and load profile prediction; power system optimization; system checkout; and data storage and transmission control. This paper describes the basic method of implementing these specific functions. The APSM hardware includes a central power system computer and a processor dedicated to each major power system subassembly along with digital interface circuitry. The major payoffs anticipated are in enhancement of spacecraft reliability and life and reduction of overall spacecraft program cost.

  20. Corrective Measures for the Effective Load Management and Control Under Disturbance at Bhusawal Thermal Power Station: Case Study

    NASA Astrophysics Data System (ADS)

    Ballal, Makarand Sudhakar; Ballal, Deepali Makarand; Suryawanshi, Hiralal Murlidhar; Mishra, Mahesh Kumar

    2014-04-01

    A modern power grid needs to become smarter in order to provide an affordable, reliable, and sustainable supply of electricity. The objective of this work is to investigate the discrepancies in power flow control under the abnormal circumstances and to maintain grid stability. This paper reports investigation into the factors that influence the dynamic behavior of the power control from Bhusawal Thermal Power Station (BTPS), India. The problems of existing power system are discussed by considering the case studies of BTPS substation and very efficient solutions are proposed to resolves these hurdles. Load flow studies are carried out for different cases, considering realistic load condition before and after disturbances. Simulation is performed in MATLAB environment and recorded parameters are compared with simulation results.

  1. Poynting vector analysis for wireless power transfer between magnetically coupled coils with different loads.

    PubMed

    Guo, Yunsheng; Li, Jiansheng; Hou, Xiaojuan; Lv, Xiaolong; Liang, Hao; Zhou, Ji; Wu, Hongya

    2017-04-07

    Wireless power transfer is a nonradiative type of transmission that is performed in the near-field region. In this region, the electromagnetic fields that are produced by both the transmitting and receiving coils are evanescent fields, which should not transmit energy. This then raises the question of how the energy can be transferred. Here we describe a theoretical study of the two evanescent field distributions at different terminal loads. It is shown that the essential principle of wireless energy transfer is the superposition of the two evanescent fields, and the resulting superimposed field is mediated through the terminal load. If the terminal load is either capacitive or inductive, then the superimposed field cannot transfer the energy because its Poynting vector is zero; in contrast, if the load is resistive, energy can then be conveyed from the transmitting coil to the receiving coil. The simulation results for the magnetic field distributions and the time-domain current waveforms agree very well with the results of the theoretical analysis. This work thus provides a comprehensive understanding of the energy transfer mechanism involved in the magnetic resonant coupling system.

  2. Smart Grid - Transforming Power System Operations

    SciTech Connect

    Widergren, Steven E.; Kirkham, Harold

    2010-04-28

    Abstract—Electric power systems are entering a new realm of operations. Large amounts of variable generation tax our ability to reliably operate the system. Couple this with a greater reliance on the electricity network to serve consumer demand that is likely to rise significantly even as we drive for greater efficiency. Trade-offs between energy and environmental needs will be constantly negotiated, while a reliable supply of electricity needs even greater assurance in a world where threats of disruption have risen. Smart grid capabilities are being proposed to help address the challenges confronting system operations. This paper reviews the impact of smart grid functionality on transforming power system operations. It explores models for distributed energy resources (DER – generation, storage, and load) that are appearing on the system. It reviews the evolving nature of electricity markets to deal with this complexity and a change of emphasis on signals from these markets to affect power system control. Smart grid capabilities will also impact reliable operations, while cyber security issues must be addressed as a culture change that influences all system design, implementation, and maintenance. Lastly, the paper explores significant questions for further research and the need for a simulation environment that supports such investigation and informs deployments to mitigate operational issues as they arise.

  3. Design description of the Schuchuli village photovoltaic power system

    SciTech Connect

    Ratajczak, A.F.; Vasicek, R.W.; DeLombard, R.

    1981-05-01

    The engineering design of a stand-alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is described. The purpose of this experiment was to demonstrate that a stand-alone photovoltaic power system could provide dependable power for basic human needs in a remote village environment. The power system was designed as a limited energy, all 120-V(d.c.) system to which loads cannot be arbitrarily added. The system consists of a 3.5-kW (peak) PV array, 2380 ampere-hours of battery storage, an Electrical Equipment Building, a 120-V(d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, and a sewing machine in the Domestic Services Building; and lights for each of the homes and communal buildings. In addition, a solar hot water heater was provided to supply hot water for the washing machine and communal laundry. The system employs automatic control systems which provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority loads at the expense of low priority loads as the main battery becomes depleted. The engineering design includes loads profiles and loads descriptions; an explanation of the PV array and battery sizing methodology; descriptions of the mechanical designs; electrical designs and descriptions of the array, battery, controls, instrumentation and distribution system; and a discussion of safety features.

  4. Solar Power Satellite Microwave Power Transmission System Description Executive Summary

    NASA Technical Reports Server (NTRS)

    Woodcock, G. R.

    1980-01-01

    The history of the concept of microwave power beaming to Earth is reviewed with emphasis on transmission frequency selection. Constraints on the system power level results from (1) required rejection of waste heat resulting from inefficiencies in the cover conversion of dc electric power to microwave power; (2) the rf power intensity in the ionosphere; and (3) the effect of sidelobe level on aperture illumination factors. Transmitter arrangement, the power distribution system, attitude control, subarrays, waveguides, and alignment are discussed.

  5. Controlling power systems during emergencies

    SciTech Connect

    Kirschen, D.S.; Wollenberg, B.F.; Irisarri, G.D.; Bann, J.J.; Miller, B.N.

    1989-04-01

    Economic and social factors in many parts of the world now require power systems to be operated at less generation reserve and closer to transmission flow and contingency voltage limits than formerly practiced. The result has been an increase in the complexity of power systems operations. The installation of computerized Energy Management Systems (EMS) has helped alleviate some of these difficulties: Supervisory Control And Data-Acquisition (SCADA) systems have made possible the centralization of the decision-making process. Advanced applications such as optimal power flow and security analysis have helped operators maintain the system in a secure and optimal state. Expert system technology is now being implemented in EMS installations to provide operators with the tools necessary to meet the needs just described. This article explores some applications of expert systems to power system control and shows how they can be used to alleviate the burden on the operators during emergency periods. To this end, the design and implementation of two applications are presented: An intelligent alarm processor (IAP); and A program for the diagnosis of system faults (DSF).

  6. 76 FR 48159 - Integrated System Power Rates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-08

    ... Southwestern Power Administration Integrated System Power Rates AGENCY: Southwestern Power Administration, DOE... component of the Integrated System rates for power and energy, the Purchased Power Adder (PPA), produces... finalized Integrated System Rate Proposal, Power Repayment Studies, and Rate Design Study in support of the...

  7. Velocity- and power-load relationships of the bench pull vs. bench press exercises.

    PubMed

    Sánchez-Medina, L; González-Badillo, J J; Pérez, C E; Pallarés, J G

    2014-03-01

    This study compared the velocity- and power-load relationships of the antagonistic upper-body exercises of prone bench pull (PBP) and bench press (BP). 75 resistance-trained athletes performed a progressive loading test in each exercise up to the one-repetition maximum (1RM) in random order. Velocity and power output across the 30-100% 1RM were significantly higher for PBP, whereas 1RM strength was greater for BP. A very close relationship was observed between relative load and mean propulsive velocity for both BP (R2=0.97) and PBP (R2=0.94) which enables us to estimate %1RM from velocity using the obtained prediction equations. Important differences in the load that maximizes power output (Pmax) and the power profiles of both exercises were found according to the outcome variable used: mean (MP), peak (PP) or mean propulsive power (MPP). When MP was considered, the Pmax load was higher (56% BP, 70% PBP) than when PP (37% BP, 41% PBP) or MPP (37% BP, 46% PBP) were used. For each variable there was a broad range of loads at which power output was not significantly different. The differing velocity- and power-load relationships between PBP and BP seem attributable to the distinct muscle architecture and moment arm levers involved in these exercises. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Parallel processing methods for space based power systems

    NASA Technical Reports Server (NTRS)

    Berry, F. C.

    1993-01-01

    This report presents a method for doing load-flow analysis of a power system by using a decomposition approach. The power system for the Space Shuttle is used as a basis to build a model for the load-flow analysis. To test the decomposition method for doing load-flow analysis, simulations were performed on power systems of 16, 25, 34, 43, 52, 61, 70, and 79 nodes. Each of the power systems was divided into subsystems and simulated under steady-state conditions. The results from these tests have been found to be as accurate as tests performed using a standard serial simulator. The division of the power systems into different subsystems was done by assigning a processor to each area. There were 13 transputers available, therefore, up to 13 different subsystems could be simulated at the same time. This report has preliminary results for a load-flow analysis using a decomposition principal. The report shows that the decomposition algorithm for load-flow analysis is well suited for parallel processing and provides increases in the speed of execution.

  9. Ultracapacitor-Based Uninterrupted Power Supply System

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.

    2011-01-01

    The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less

  10. Optical power source control system

    NASA Astrophysics Data System (ADS)

    Husbands, C. R.

    1984-05-01

    An optical power source control system having a four port optical coupler, an optical receiver and associated comparator circuits operably connected to the optical transmission line connecting the source to an output connector. When the output connector is mated with another connector, the receiver senses the optical energy reflected from the glass/air and air/glass interfaces of the connectors and provides an appropriate signal. This signal is sufficiently high when compared to a threshold voltage level to permit the power source to operate. When the output connector is in the unmated condition the reflected optical power from the air/glass interface is no longer present and therefore the signal from the receiver falls below the threshold voltage level. With this reduced signal level, power flow to the optical source is removed or reduced thereby controlling the operation of the optical power source.

  11. Space Heating Load Estimation Procedure for CHP Systems sizing

    NASA Astrophysics Data System (ADS)

    Vocale, P.; Pagliarini, G.; Rainieri, S.

    2015-11-01

    Due to its environmental and energy benefits, the Combined Heat and Power (CHP) represents certainly an important measure to improve energy efficiency of buildings. Since the energy performance of the CHP systems strongly depends on the fraction of the useful cogenerated heat (i.e. the cogenerated heat that is actually used to meet building thermal demand), in building applications of CHP, it is necessary to know the space heating and cooling loads profile to optimise the system efficiency. When the heating load profile is unknown or difficult to calculate with a sufficient accuracy, as may occur for existing buildings, it can be estimated from the cumulated energy uses by adopting the loads estimation procedure (h-LEP). With the aim to evaluate the useful fraction of the cogenerated heat for different operating conditions in terms of buildings characteristics, weather data and system capacity, the h-LEP is here implemented with a single climate variable: the hourly average dry- bulb temperature. The proposed procedure have been validated resorting to the TRNSYS simulation tool. The results, obtained by considering a building for hospital use, reveal that the useful fraction of the cogenerated heat can be estimated with an average accuracy of ± 3%, within the range of operative conditions considered in the present study.

  12. Solar Dynamic Power System Stability Analysis and Control

    NASA Technical Reports Server (NTRS)

    Momoh, James A.; Wang, Yanchun

    1996-01-01

    The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.

  13. Peak power and blade loads on stall-regulated rotors as influenced by different airfoil families

    SciTech Connect

    Tangler, J.L.; Tu, P.K.C.

    1988-08-01

    At the Solar Energy Research Institute (SERI), new airfoils have been developed to help improve the performance and economics of horizontal-axis wind turbines (HAWTS). The objective of this study was to compare the performance characteristics of one of these airfoil families to other commonly used airfoil series for a typical three-bladed, stall-regulated HAWT. The traditional airfoil series chosen for comparison with SERI's new thin airfoil family were the NACA 23XXX, NACA 44XX, and NASA LS(1). The Micon 110 wind turbine was chosen because it is a typical three-bladed, stall-regulated rigid rotor system. The performance characteristics of the different airfoil series were derived analytically using the Eppler airfoil design code in the analysis mode. On a relative basis, this approach to comparing airfoils was considered more accurate than using airfoil performance characteristics based on wind-tunnel test data. After generating the performance characteristics for each airfoil series, the subsequent rotor performance and blade loads were calculated using SERI's PROPSH computer code. Resulting annual energy output, which is dependent on the wind-speed distribution, was calculated using SERI's Systems Engineering and Analysis Computer Code (SEACC). The results of the study show that fixed-wing airfoils generally result in excessive peak power for stall regulated, rigid rotors. By operating the wind turbine at a less desirable blade pitch angle, peak power can be reduced at the expense of higher mean blade loads and lower annual energy output. In contrast, the thin airfoil family was designed to reduce peak power at optimum blade pitch to minimize blade loads and maximize annual energy output. 7 refs., 12 figs.

  14. Piezoelectric power generation for civil infrastructure systems

    NASA Astrophysics Data System (ADS)

    Erturk, A.; Inman, D. J.

    2011-04-01

    Civil infrastructure systems (CIS) employ various small electronic components ranging from temperature and humidity sensors used in buildings to acoustics emission sensors used for damage detection in bridges. Other than solar energy that has already found several applications in CIS; moving loads, surface strain fluctuations, and wind energy available in the vicinity of CIS constitute important sources of energy that can be converted into electricity. This paper focuses on low power generation from these energy sources using piezoelectric transduction. Moving loads caused by travelling vehicles can be used for exciting piezoceramics located on the road. Structural vibrations resulting from various sources such as support motions and interaction of CIS with the surrounding fluid may yield local surface strain fluctuations. Wind energy is available not only due to regular atmospheric flow but also due to the motion of vehicles travelling at relatively high speeds. This paper investigates and formulates (1) the electromechanical moving load problem for slender bridges with a piezoelectric cantilever and with embedded piezoceramics, (2) the problem of piezoelectric power generation from surface strain fluctuations using a piezoceramic patch, and (3) piezoelectric energy harvesting from wind excitation through aeroelastic flutter.

  15. Load calculation and system evaluation for electric vehicle climate control

    SciTech Connect

    Aceves-Saborio, S.; Comfort, W.J. III

    1993-10-27

    Providing air conditioning for electric vehicles (EVs) represents an important challenge, because vapor compression air conditioners, which are common in gasoline powered vehicles, may consume a substantial part of the total energy stored in the EV battery. This report consists of two major parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can be used to provide the desired cooling and heating in EVs. Four cases are studied. Short range and full range EVs are each analyzed twice, first with the regular vehicle equipment, and then with a fan and heat reflecting windows, to reduce hot soak. Recent legislation has allowed the use of combustion heating whenever the ambient temperature drops below 5{degrees}C. This has simplified the problem of heating, and made cooling the most important problem. Therefore, systems described in this project are designed for cooling, and their applicability to heating at temperatures above 5{degrees}C is described. If the air conditioner systems cannot be used to cover the whole heating load at 5{degrees}C, then the vehicle requires a complementary heating system (most likely a heat recovery system or electric resistance heating). Air conditioners are ranked according to their overall weight. The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation.

  16. Effects of loading and size on maximum power output and gait characteristics in geckos.

    PubMed

    Irschick, Duncan J; Vanhooydonck, Bieke; Herrel, Anthony; Andronescu, Anemone

    2003-11-01

    Stride length, stride frequency and power output are all factors influencing locomotor performance. Here, we first test whether mass-specific power output limits climbing performance in two species of geckos (Hemidactylus garnoti and Gekko gecko) by adding external loads to their bodies. We then test whether body size has a negative effect on mass-specific power output. Finally, we test whether loading affects kinematics in both gecko species. Lizards were induced to run vertically on a smooth wooden surface with loads of 0-200% of body mass (BM) in H. garnoti and 0-100% BM in G. gecko. For each stride, we calculated angular and linear kinematics (e.g. trunk angle, stride length), performance (maximum speed) and mean mass-specific power output per stride. The addition of increasingly large loads caused an initial increase in maximum mass-specific power output in both species, but for H. garnoti, mass-specific power output remained constant at higher loads (150% and 200% BM), even though maximum velocity declined. This result, in combination with the fact that stride frequency showed no evidence of leveling off as speed increased in either species, suggests that power limits maximum speed. In addition, the large gecko (G. gecko) produced significantly less power than the smaller H. garnoti, despite the fact that both species ran at similar speeds. This difference disappeared, however, when we recalculated power output based on higher maximum speeds for unloaded G. gecko moving vertically obtained by other researchers. Finally, the addition of external loads did not affect speed modulation in either species: both G. gecko and H. garnoti increase speed primarily by increasing stride frequency, regardless of loading condition. For a given speed, both species take shorter but more strides with heavier loads, but for a given load, G. gecko attains similar speeds to H. garnoti by taking longer but fewer strides.

  17. Solar-powered cooling system

    SciTech Connect

    Farmer, Joseph C

    2013-12-24

    A solar-powered adsorption-desorption refrigeration and air conditioning system uses nanostructural materials made of high specific surface area adsorption aerogel as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material. A circulation system circulates refrigerant from the nanostructural material to a cooling unit.

  18. Mine shaft conveyance load-monitoring system

    SciTech Connect

    Beus, M.J.; McCoy, W.G.

    1995-12-31

    Technology to enhance safety features for mine shafts and elevators is being investigated by researchers at the US Bureau of Mines. The objective of this research is to prevent injuries and fatalities related to hoist and elevator operations. Mine Safety and Health Administration statistics indicate that several factors contribute to hoisting accidents. A significant number of these factors are related to lack of adequate information on the position of the conveyance coupled with slack or overloaded rope resulting from obstructions or misalignments in the hoistway. Typically, this information is determined from sensors located in the hoist room. Subsequently, hoist and elevator control may be compromised and accidents result. This paper describes development of a slack rope sensor and data-transmission and collection hardware to sense conditions and acquire data directly from the hoisting conveyance. A new type of load cell senses wire rope tension at the conveyance. A new type of load cell senses wire rope tension at the conveyance. A multichannel signal processing board has been designed and fabricated and is undergoing both static testing to evaluate long-term stability and dynamic testing under simulated hoisting conditions. Analog signals from the sensors are sampled at 100-ms intervals. Data transmission between the moving conveyance and the hoistroom is accomplished via a 2,400-baud FM radio modem. Data are acquired at the conveyance or in the hoistroom through a serial communications port on a laptop computer. Software has been written to acquire, analyze, and process the data. The resulting system will allow operating personnel to determine conveyance load, and thus rope tension and slack or overload rope conditions, in relation to conveyance position in the hoistway.

  19. Integrated high power VCSEL systems

    NASA Astrophysics Data System (ADS)

    Moench, Holger; Conrads, Ralf; Gronenborn, Stephan; Gu, Xi; Miller, Michael; Pekarski, Pavel; Pollmann-Retsch, Jens; Pruijmboom, Armand; Weichmann, Ulrich

    2016-03-01

    High power VCSEL systems are a novel laser source used for thermal treatment in industrial manufacturing. These systems will be applied in many applications, which have not used a laser source before. This is enabled by the unique combination of efficiency, compactness and robustness. High power VCSEL system technology encompasses elements far beyond the VCSEL chip itself: i.e. heat sinks, bonding technology and integrated optics. This paper discusses the optimization of these components and processes specifically for building high-power laser systems with VCSEL arrays. New approaches help to eliminate components and process steps and make the system more robust and easier to manufacture. New cooler concepts with integrated electrical and mechanical interfaces have been investigated and offer advantages for high power system design. The bonding process of chips on sub-mounts and coolers has been studied extensively and for a variety of solder materials. High quality of the interfaces as well as good reliability under normal operation and thermal cycling have been realized. A viable alternative to soldering is silver sintering. The very positive results which have been achieved with a variety of technologies indicate the robustness of the VCSEL chips and their suitability for high power systems. Beam shaping micro-optics can be integrated on the VCSEL chip in a wafer scale process by replication of lenses in a polymer layer. The performance of VCSEL arrays with integrated collimation lenses has been positively evaluated and the integrated chips are fully compatible with all further assembly steps. The integrated high power systems make the application even easier and more robust. New examples in laser material processing and pumping of solid state lasers are presented.

  20. Technological inductive power transfer systems

    NASA Astrophysics Data System (ADS)

    Madzharov, Nikolay D.; Nemkov, Valentin S.

    2017-05-01

    Inductive power transfer is a very fast expanding technology with multiple design principles and practical implementations ranging from charging phones and computers to bionic systems, car chargers and continuous power transfer in technological lines. Only a group of devices working in near magnetic field is considered. This article is devoted to overview of different inductive power transfer (IPT) devices. The review of literature in this area showed that industrial IPT are not much discussed and examined. The authors have experience in design and implementation of several types of IPTs belonging to wireless automotive chargers and to industrial application group. Main attention in the article is paid to principles and design of technological IPTs