29 CFR 1910.242 - Hand and portable powered tools and equipment, general.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2011-07-01 2011-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...
29 CFR 1910.242 - Hand and portable powered tools and equipment, general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. ... 29 Labor 5 2010-07-01 2010-07-01 false Hand and portable powered tools and equipment, general... Powered Tools and Other Hand-Held Equipment § 1910.242 Hand and portable powered tools and equipment...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 56.14116 - Hand-held power tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 56.14116 Section 56... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
30 CFR 57.14116 - Hand-held power tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held power tools. 57.14116 Section 57... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14116 Hand-held power tools. (a) Power drills...
Hand and power tools: A compilation
NASA Technical Reports Server (NTRS)
1976-01-01
Some hand and power tools were described. Section One describes several tools and shop techniques that may be useful in the home or commercial shop. Section Two contains descriptions of tools that are particularly applicable to industrial work, and in Section Three a number of metal working tools are presented.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.301 Hand tools. (a) Employers shall not issue or permit the use of unsafe hand tools. (b) Wrenches, including adjustable, pipe, end...
Ergonomic analysis of fastening vibration based on ISO Standard 5349 (2001).
Joshi, Akul; Leu, Ming; Murray, Susan
2012-11-01
Hand-held power tools used for fastening operations exert high dynamic forces on the operator's hand-arm, potentially causing injuries to the operator in the long run. This paper presents a study that analyzed the vibrations exerted by two hand-held power tools used for fastening operations with the operating exhibiting different postures. The two pneumatic tools, a right-angled nut-runner and an offset pistol-grip, are used to install shearing-type fasteners. A tri-axial accelerometer is used to measure the tool's vibration. The position and orientation of the transducer mounted on the tool follows the ISO-5349 Standard. The measured vibration data is used to compare the two power tools at different operating postures. The data analysis determines the number of years required to reach a 10% probability of developing finger blanching. The results indicate that the pistol-grip tool induces more vibration in the hand-arm than the right-angled nut-runner and that the vibrations exerted on the hand-arm vary for different postures. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Analysis of Facial Injuries Caused by Power Tools.
Kim, Jiye; Choi, Jin-Hee; Hyun Kim, Oh; Won Kim, Sug
2016-06-01
The number of injuries caused by power tools is steadily increasing as more domestic woodwork is undertaken and more power tools are used recreationally. The injuries caused by the different power tools as a consequence of accidents are an issue, because they can lead to substantial costs for patients and the national insurance system. The increase in hand surgery as a consequence of the use of power tools and its economic impact, and the characteristics of the hand injuries caused by power saws have been described. In recent years, the authors have noticed that, in addition to hand injuries, facial injuries caused by power tools commonly present to the emergency room. This study aimed to review the data in relation to facial injuries caused by power saws that were gathered from patients who visited the trauma center at our hospital over the last 4 years, and to analyze the incidence and epidemiology of the facial injuries caused by power saws. The authors found that facial injuries caused by power tools have risen continually. Facial injuries caused by power tools are accidental, and they cause permanent facial disfigurements and functional disabilities. Accidents are almost inevitable in particular workplaces; however, most facial injuries could be avoided by providing sufficient operator training and by tool operators wearing suitable protective devices. The evaluation of the epidemiology and patterns of facial injuries caused by power tools in this study should provide the information required to reduce the number of accidental injuries.
1998-01-01
equipped with a constant- pressure switch or control: drills; tappers; fastener drivers; horizontal, vertical, and angle grinders with wheels more than...hand-held power tools must be equipped with either a positive “on-off” control switch, a constant pressure switch , or a “lock-on” control: disc sanders...percussion tools with no means of holding accessories securely, must be equipped with a constant- pressure switch that will shut off the power when the
Electrically powered hand tool
Myers, Kurt S.; Reed, Teddy R.
2007-01-16
An electrically powered hand tool is described and which includes a three phase electrical motor having a plurality of poles; an electrical motor drive electrically coupled with the three phase electrical motor; and a source of electrical power which is converted to greater than about 208 volts three-phase and which is electrically coupled with the electrical motor drive.
Zhang, Jiang; Yuan, Zhen; Huang, Jin; Yang, Qin; Chen, Huafu
2014-12-01
Motor imagery is an experimental paradigm implemented in cognitive neuroscience and cognitive psychology. To investigate the asymmetry of the strength of cortical functional activity due to different single-hand motor imageries, functional magnetic resonance imaging (fMRI) data from right handed normal subjects were recorded and analyzed during both left-hand and right-hand motor imagery processes. Then the average power of blood oxygenation level-dependent (BOLD) signals in temporal domain was calculated using the developed tool that combines Welch power spectrum and the integral of power spectrum approach of BOLD signal changes during motor imagery. Power change analysis results indicated that cortical activity exhibited a stronger power in the precentral gyrus and medial frontal gyrus with left-hand motor imagery tasks compared with that from right-hand motor imagery tasks. These observations suggest that right handed normal subjects mobilize more cortical nerve cells for left-hand motor imagery. Our findings also suggest that the approach based on power differences of BOLD signals is a suitable quantitative analysis tool for quantification of asymmetry of brain activity intensity during motor imagery tasks. Copyright © 2014 Elsevier Inc. All rights reserved.
Safety with Hand and Portable Power Tools. Module SH-14. Safety and Health.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This student module on safety with hand and portable power tools is one of 50 modules concerned with job safety and health. This module discusses the proper use and maintenance of tools, including the need for protective equipment for the worker. Following the introduction, 16 objectives (each keyed to a page in the text) the student is expected…
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF SMALL HAND TOOLS USED IN DIESEL ENGINE MAINTENANCE AND THE OPERATING PRINCIPLES AND MAINTENANCE OF POWER DIVIDERS (GEAR BOXES) USED IN DIESEL ENGINE POWER DISTRIBUTION. TOPICS ARE (1) UNDERSTANDING TORQUE AND HOW IT IS MEASURED, (2) REPAIRING AND REPLACING THREADED…
Easy Ergonomics: A Guide to Selecting Non-Powered Hand Tools
... identifying the presence or absence of basic ergonomic design features (Dababneh et al.*). The right tool will ... Cal/OSHA). Both agencies recognize the importance of design and selection of hand tools in strategies to ...
29 CFR 1926.304 - Woodworking tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.304 Woodworking tools. (a) Disconnect switches. All fixed power driven woodworking tools shall be provided with a disconnect..., power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The...
Chapter 03: Correct use of a hand lens
Alex Wiedenhoeft
2011-01-01
A hand lens is a powerful tool for the identification of wood, but like all tools it must be used correctly to take full advantage of its powers. The hand lens has two main parts, a lens that magnifies the object of interest (generally we use 10X or 14X lenses in wood identification; a 14X lens is recommended for use with this manual) and a housing to hold and protect...
Noise reduction techniques in the design of a pneumatic-driven hand held power tool
NASA Astrophysics Data System (ADS)
Skinner, Christian M.
2005-09-01
Pneumatic-driven hand-held power tools generate noise in the workplace. Current legislation in Europe and the USA aims at protecting workers against noise exposure. In the United States, the Occupational Safety and Health Administration (OSHA) requires that employers create a hearing conservation program if the noise exposure exceeds 85 dB(A). In the European Community under the Directive 2003/10/EC, employers are required to provide hearing protection if the noise exposure within the working environment exceeds 80 dB(A) and must require hearing protection to be worn if the noise exposure exceeds 85 dB(A). This paper examines the sources of noise which contribute to the overall noise from a hand-held power tool. A test plan was developed to identify these individual sources of noise and to determine if structure-borne noise or airborne noise is the dominant source relative to the overall noise level. The measurements were performed per International Standards Organization (ISO) 15744. This paper will describe the methodology used to identify the noise sources and reduce the overall noise of a hand-held power tool.
Occupational Safety. Hand Tools. Pre-Apprenticeship Phase 1 Training.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This self-paced student training module on safety when using hand tools is one of a number of modules developed for Pre-apprenticeship Phase 1 Training. Purpose of the module is to teach students the correct safety techniques for operating common hand- and arm-powered tools, including selection, maintenance, technique, and uses. The module may…
Impact of design features upon perceived tool usability and safety
NASA Astrophysics Data System (ADS)
Wiker, Steven F.; Seol, Mun-Su
2005-11-01
While injuries from powered hand tools are caused by a number of factors, this study looks specifically at the impact of the tools design features on perceived tool usability and safety. The tools used in this study are circular saws, power drills and power nailers. Sixty-nine males and thirty-two females completed an anonymous web-based questionnaire that provided orthogonal view photographs of the various tools. Subjects or raters provided: 1) description of the respondents or raters, 2) description of the responses from the raters, and 3) analysis of the interrelationships among respondent ratings of tool safety and usability, physical metrics of the tool, and rater demographic information. The results of the study found that safety and usability were dependent materially upon rater history of use and experience, but not upon training in safety and usability, or quality of design features of the tools (e.g., grip diameters, trigger design, guards, etc.). Thus, positive and negative transfer of prior experience with use of powered hand tools is far more important than any expectancy that may be driven by prior safety and usability training, or from the visual cues that are provided by the engineering design of the tool.
General Construction Trades. Volume 1. Teacher's Guide.
ERIC Educational Resources Information Center
East Texas State Univ., Commerce. Occupational Curriculum Lab.
Ten units on the world of construction and twelve units on carpentry are presented in this teacher's guide. The construction units include the following: safety; human relations in the shop; grooming and hygiene; hand tools; measurement; portable power tools, stationary power tools; fastening devices; and job application and interview. The…
NASA Astrophysics Data System (ADS)
Dong, Jennie H.; Dong, Ren G.; Rakheja, Subhash; Welcome, Daniel E.; McDowell, Thomas W.; Wu, John Z.
2008-04-01
In this study it was hypothesized that the vibration-induced injuries or disorders in a substructure of human hand-arm system are primarily associated with the vibration power absorption distributed in that substructure. As the first step to test this hypothesis, the major objective of this study is to develop a method for analyzing the vibration power flow and the distribution of vibration power absorptions in the major substructures (fingers, palm-hand-wrist, forearm and upper arm, and shoulder) of the system exposed to hand-transmitted vibration. A five-degrees-of-freedom model of the system incorporating finger- as well as palm-side driving points was applied for the analysis. The mechanical impedance data measured at the two driving points under four different hand actions involving 50 N grip-only, 15 N grip and 35 N push, 30 N grip and 45 N push, and 50 N grip and 50 N push, were used to identify the model parameters. The vibration power absorption distributed in the substructures were evaluated using vibration spectra measured on many tools. The frequency weightings of the distributed vibration power absorptions were derived and compared with the weighting defined in ISO 5349-1 (2001). This study found that vibration power absorption is primarily distributed in the arm and shoulder when operating low-frequency tools such as rammers, while a high concentration of vibration power absorption in the fingers and hand is observed when operating high-frequency tools, such as grinders. The vibration power absorption distributed in palm-wrist and arm is well correlated with the ISO-weighted acceleration, while the finger vibration power absorption is highly correlated with unweighted acceleration. The finger vibration power absorption-based frequency weighting suggested that exposure to vibration in the frequency range of 16-500 Hz could pose higher risks of developing finger disorders. The results support the use of the frequency weighting specified in the current standard for assessing risks of developing disorders in the palm-wrist-arm substructures. The standardized weighting, however, could overestimate low-frequency effects but greatly underestimate high-frequency effects on the development of finger disorders. The results are further discussed to show that the trends observed in the vibration power absorptions distributed in the substructures are consistent with some major findings of various physiological and epidemiological studies, which provides a support to the hypothesis of this study.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Order No. 1803] Approval for Manufacturing Authority; Foreign-Trade Zone 26; Makita Corporation of America; (Hand-Held/Stationary Power Tool and Gasoline/Electric-Powered Lawn and Garden Product Manufacturing); Buford, GA Pursuant to its authority...
A better way of fitting clips? A comparative study with respect to physical workload.
Gaudez, Clarisse; Wild, Pascal; Aublet-Cuvelier, Agnès
2015-11-01
The clip fitting task is a frequently encountered assembly operation in the car industry. It can cause upper limb pain. During task laboratory simulations, upper limb muscular activity and external force were compared for 4 clip fitting methods: with the bare hand, with an unpowered tool commonly used at a company and with unpowered and powered prototype tools. None of the 4 fitting methods studied induced a lower overall workload than the other three. Muscle activity was lower at the dominant limb when using the unpowered tools and at the non-dominant limb with the bare hand or with the powered tool. Fitting clips with the bare hand required a higher external force than fitting with the three tools. Evaluation of physical workload was different depending on whether external force or muscle activity results were considered. Measuring external force only, as recommended in several standards, is insufficient for evaluating physical workload. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Upper-limb tremor suppression with a 7DOF exoskeleton power-assist robot.
Kiguchi, Kazuo; Hayashi, Yoshiaki
2013-01-01
A tremor which is one of the involuntary motions is somewhat rhythmic motion that may occur in various body parts. Although there are several kinds of the tremor, an essential tremor is the most common tremor disorder of the arm. The essential tremor is a disorder of unknown cause, and it is common in the elderly. The essential tremor interferes with a patient's daily living activity, because it may occur during a voluntary motion. If a patient of an essential tremor uses an EMG-based controlled power-assist robot, the robot might misunderstand the user's motion intention because of the effect of the essential tremor. In that case, upper-limb power-assist robots must carry out tremor suppression as well as power-assist, since a person performs various precise tasks with certain tools by the upper-limb in daily living. Therefore, it is important to suppress the tremor at the hand and grasped tool. However, in the case of the tremor suppression control method which suppressed the vibrations of the hand and the tip of the tool, vibration of other part such as elbow might occur. In this paper, the tremor suppression control method for upper-limb power-assist robot is proposed. In the proposed method, the vibration of the elbow is suppressed in addition to the hand and the tip of the tool. The validity of the proposed method was verified by the experiments.
Lin, Jia-Hua; McGorry, Raymond W; Chang, Chien-Chi
2007-05-01
A hand-handle interface force and torque measurement system is introduced to fill the void acknowledged in the international standard ISO 6544, which governs pneumatic, assembly tool reaction torque and force measurement. This system consists of an instrumented handle with a sensor capable of measuring grip force and reaction hand moment when threaded, fastener-driving tools are used by operators. The handle is rigidly affixed to the tool in parallel to the original tool handle allowing normal fastener-driving operations with minimal interference. Demonstration of this proposed system was made with tools of three different shapes: pistol grip, right angle, and in-line. During tool torque buildup, the proposed system measured operators exerting greater grip force on the soft joint than on the hard joint. The system also demonstrated that the soft joint demanded greater hand moment impulse than the hard joint. The results demonstrate that the measurement system can provide supplemental data useful in exposure assessment with power hand tools as proposed in ISO 6544.
Evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration.
Griffin, M J
1998-05-01
A method of evaluating the effectiveness of gloves in reducing the hazards of hand-transmitted vibration is proposed. The glove isolation effectiveness was calculated from: (a) the measured transmissibility of a glove, (b) the vibration spectrum on the handle of a specific tool (or class of tools), and (c) the frequency weighting indicating the degree to which different frequencies of vibration cause injury. With previously reported tool vibration spectra and glove transmissibilities (from 10-1000 Hz), the method was used to test 10 gloves with 20 different powered tools. The frequency weighting for hand-transmitted vibration advocated in British standard 6842 (1987) and international standard 5349 (1986) greatly influences the apparent isolation effectiveness of gloves. With the frequency weighting, the gloves had little effect on the transmission of vibration to the hand from most of the tools. Only for two or three tools (those dominated by high frequency vibration) did any glove provide useful attenuation. Without the frequency weighting, some gloves showed useful attenuation of the vibration on most powered tools. In view of the uncertain effect of the vibration frequency in the causation of disorders from hand-transmitted vibration, it is provisionally suggested that the wearing of a glove by the user of a particular vibratory tool could be encouraged if the glove reduces the transmission of vibration when it is evaluated without the frequency weighting and does not increase the vibration when it is evaluated with the frequency weighting. A current international standard for the measurement and evaluation of the vibration transmitted by gloves can classify a glove as an antivibration glove when it provides no useful attenuation of vibration, whereas a glove providing useful attenuation of vibration on a specific tool can fail the test.
A computer controlled power tool for the servicing of the Hubble Space Telescope
NASA Technical Reports Server (NTRS)
Richards, Paul W.; Konkel, Carl; Smith, Chris; Brown, Lee; Wagner, Ken
1996-01-01
The Hubble Space Telescope (HST) Pistol Grip Tool (PGT) is a self-contained, microprocessor controlled, battery-powered, 3/8-inch-drive hand-held tool. The PGT is also a non-powered ratchet wrench. This tool will be used by astronauts during Extravehicular Activity (EVA) to apply torque to the HST and HST Servicing Support Equipment mechanical interfaces and fasteners. Numerous torque, speed, and turn or angle limits are programmed into the PGT for use during various missions. Batteries are replaceable during ground operations, Intravehicular Activities, and EVA's.
Hand-arm vibration syndrome: a common occupational hazard in industrialized countries.
Heaver, C; Goonetilleke, K S; Ferguson, H; Shiralkar, S
2011-06-01
Regular exposure to hand-transmitted vibration can result in symptoms and signs of peripheral vascular, neurological and other disorders collectively known as the hand-arm vibration syndrome (HAVS). A significant proportion of workers can suffer from HAVS after using vibrating power tools. HAVS is a chronic and progressive disorder. Early recognition and prevention is the key to managing vibrating tool exposures and health effects. This article gives a broad overview of the condition with a detailed account of its pathogenesis, identification and management.
Tools. Unit 9: A Core Curriculum of Related Instruction for Apprentices.
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Occupational and Career Curriculum Development.
The tool handling unit is presented to assist apprentices to acquire a general knowledge on the use of various basic tools. The unit consists of seven modules: (1) introduction to hand tools and small power tools; (2) measuring tools: layout and measuring tools for woodworking; (3) measuring tools: feeler gauge, micrometer, and torque wrench; (4)…
The use of power tools in the insertion of cortical bone screws.
Elliott, D
1992-01-01
Cortical bone screws are commonly used in fracture surgery, most patterns are non-self-tapping and require a thread to be pre-cut. This is traditionally performed using hand tools rather than their powered counterparts. Reasons given usually imply that power tools are more dangerous and cut a less precise thread, but there is no evidence to support this supposition. A series of experiments has been performed which show that the thread pattern cut with either method is identical and that over-penetration with the powered tap is easy to control. The conclusion reached is that both methods produce consistently reliable results but use of power tools is much faster.
Context and hand posture modulate the neural dynamics of tool-object perception.
Natraj, Nikhilesh; Poole, Victoria; Mizelle, J C; Flumini, Andrea; Borghi, Anna M; Wheaton, Lewis A
2013-02-01
Prior research has linked visual perception of tools with plausible motor strategies. Thus, observing a tool activates the putative action-stream, including the left posterior parietal cortex. Observing a hand functionally grasping a tool involves the inferior frontal cortex. However, tool-use movements are performed in a contextual and grasp specific manner, rather than relative isolation. Our prior behavioral data has demonstrated that the context of tool-use (by pairing the tool with different objects) and varying hand grasp postures of the tool can interact to modulate subjects' reaction times while evaluating tool-object content. Specifically, perceptual judgment was delayed in the evaluation of functional tool-object pairings (Correct context) when the tool was non-functionally (Manipulative) grasped. Here, we hypothesized that this behavioral interference seen with the Manipulative posture would be due to increased and extended left parietofrontal activity possibly underlying motor simulations when resolving action conflict due to this particular grasp at time scales relevant to the behavioral data. Further, we hypothesized that this neural effect will be restricted to the Correct tool-object context wherein action affordances are at a maximum. 64-channel electroencephalography (EEG) was recorded from 16 right-handed subjects while viewing images depicting three classes of tool-object contexts: functionally Correct (e.g. coffee pot-coffee mug), functionally Incorrect (e.g. coffee pot-marker) and Spatial (coffee pot-milk). The Spatial context pairs a tool and object that would not functionally match, but may commonly appear in the same scene. These three contexts were modified by hand interaction: No Hand, Static Hand near the tool, Functional Hand posture and Manipulative Hand posture. The Manipulative posture is convenient for relocating a tool but does not afford a functional engagement of the tool on the target object. Subjects were instructed to visually assess whether the pictures displayed correct tool-object associations. EEG data was analyzed in time-voltage and time-frequency domains. Overall, Static Hand, Functional and Manipulative postures cause early activation (100-400ms post image onset) of parietofrontal areas, to varying intensity in each context, when compared to the No Hand control condition. However, when context is Correct, only the Manipulative Posture significantly induces extended neural responses, predominantly over right parietal and right frontal areas [400-600ms post image onset]. Significant power increase was observed in the theta band [4-8Hz] over the right frontal area, [0-500ms]. In addition, when context is Spatial, Manipulative posture alone significantly induces extended neural responses, over bilateral parietofrontal and left motor areas [400-600ms]. Significant power decrease occurred primarily in beta bands [12-16, 20-25Hz] over the aforementioned brain areas [400-600ms]. Here, we demonstrate that the neural processing of tool-object perception is sensitive to several factors. While both Functional and Manipulative postures in Correct context engage predominantly an early left parietofrontal circuit, the Manipulative posture alone extends the neural response and transitions to a late right parietofrontal network. This suggests engagement of a right neural system to evaluate action affordances when hand posture does not support action (Manipulative). Additionally, when tool-use context is ambiguous (Spatial context), there is increased bilateral parietofrontal activation and, extended neural response for the Manipulative posture. These results point to the existence of other networks evaluating tool-object associations when motoric affordances are not readily apparent and underlie corresponding delayed perceptual judgment in our prior behavioral data wherein Manipulative postures had exclusively interfered in judging tool-object content. Copyright © 2012 Elsevier Ltd. All rights reserved.
Fatal hand tool injuries in construction.
Trent, R B; Wyant, W D
1990-08-01
Past research on occupational hand tool injuries has generally focused on nonfatal injuries. Most such injuries occur at the point where energy is transferred to the material being worked, eg, at the edge of a saw blade or the point of a drill. Assuming that hand tool injuries that are fatal will differ from nonfatal injuries, 62 Occupation Safety and Health Administration reports were analyzed. Four patterns emerged when the type of contact with energy was used to classify incidents. Fatal injuries occurred when (1) contact was made with energy that supplies power to the hand tool, (2) energy normally transferred to the material being worked is transferred to the worker, (3) workers or materials fall, and (4) potential energy is encountered in the work environment. Analysis showed that almost all such injuries could be prevented by application of existing safe work practices.
"Digit Anatomy": A New Technique for Learning Anatomy Using Motor Memory
ERIC Educational Resources Information Center
Oh, Chang-Seok; Won, Hyung-Sun; Kim, Kyong-Jee; Jang, Dong-Su
2011-01-01
Gestural motions of the hands and fingers are powerful tools for expressing meanings and concepts, and the nervous system has the capacity to retain multiple long-term motor memories, especially including movements of the hands. We developed many sets of successive movements of both hands, referred to as "digit anatomy," and made…
Cluster: Carpentry. Course: Carpentry. Research Project.
ERIC Educational Resources Information Center
Sanford - Lee County Schools, NC.
The course on carpentry is divided into 14 sequential units, with several task packages within each, covering the following topics: carpentry hand tools; portable power tools; working machine tools; lumber; fasteners and adhesives; plans, specifications, and codes for houses; footings and foundations for a house; household cabinets; floor framing…
Modeling and MBL: Software Tools for Science.
ERIC Educational Resources Information Center
Tinker, Robert F.
Recent technological advances and new software packages put unprecedented power for experimenting and theory-building in the hands of students at all levels. Microcomputer-based laboratory (MBL) and model-solving tools illustrate the educational potential of the technology. These tools include modeling software and three MBL packages (which are…
Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity
NASA Technical Reports Server (NTRS)
1986-01-01
The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
Initiating a Programmatic Assessment Report
ERIC Educational Resources Information Center
Berkaliev, Zaur; Devi, Shavila; Fasshauer, Gregory E.; Hickernell, Fred J.; Kartal, Ozgul; Li, Xiaofan; McCray, Patrick; Whitney, Stephanie; Zawojewski, Judith S.
2014-01-01
In the context of a department of applied mathematics, a program assessment was conducted to assess the departmental goal of enabling undergraduate students to recognize, appreciate, and apply the power of computational tools in solving mathematical problems that cannot be solved by hand, or would require extensive and tedious hand computation. A…
ERIC Educational Resources Information Center
Beausaert, Simon A. J.; Segers, Mien S. R.; Gijselaers, Wim H.
2011-01-01
Today, organizations are increasingly implementing assessment tools such as Personal Development Plans. Although the true power of the tool lies in supporting the employee's continuing professional development, organizations implement the tool for various different purposes, professional development purposes on the one hand and promotion/salary…
Mancarella, Luana; Addimanda, Olga; Cavallari, Carlotta; Meliconi, Riccardo
2017-01-01
Ultrasound is one of the most promising candidates for the detection of inflammation and structural damage in hand osteoarthritis. To evaluate new advances of US as a diagnostic and prognostic tool in hand osteoarthritis assessment. We conducted a Medline on PubMed search for articles about "ultrasonography" and "hand OA" published between January 2012 and 15th April 2016, limiting our search to articles on human adults in English, excluding those involving systemic inflammatory diseases, visualization of joints other than hands, ultrasound guided injections and surgical procedures. Reviews, case reports, letters, position statements and ex vivo studies were excluded. Concordance between ultrasound and conventional radiography and magnetic resonance imaging was evaluated. Total 46 records were identified, and 16 articles were selected: four showed only ultrasound structural damage (osteophytes, cartilage pathology), six only ultrasound inflammatory variables (synovial thickness, effusion and power Doppler signal), six should considered both ultrasound structural and inflammatory features as well as erosions and two were epidemiological studies. Ultrasound synovitis and power Doppler signal were more frequent in erosive hand osteoarthritis. Followup studies found that ultrasound inflammatory features at baseline are independently associated with radiographic progression; power Doppler signal was the strongest predictor of structural damage. Ultrasound is a reliable tool for cartilage and osteophyte assessment (when performed with static images) and shows a good concordance with magnetic resonance imaging for osteophytes, erosions and synovitis. Ultrasound detected inflammation may predict radiographic progression and may be used in prospective clinical trials of hand osteoarthritis and in everyday clinical practice. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Introducing Graduate Students to High-Resolution Mass Spectrometry (HRMS) Using a Hands-On Approach
ERIC Educational Resources Information Center
Stock, Naomi L.
2017-01-01
High-resolution mass spectrometry (HRMS) features both high resolution and high mass accuracy and is a powerful tool for the analysis and quantitation of compounds, determination of elemental compositions, and identification of unknowns. A hands-on laboratory experiment for upper-level undergraduate and graduate students to investigate HRMS is…
Linear modeling of human hand-arm dynamics relevant to right-angle torque tool interaction.
Ay, Haluk; Sommerich, Carolyn M; Luscher, Anthony F
2013-10-01
A new protocol was evaluated for identification of stiffness, mass, and damping parameters employing a linear model for human hand-arm dynamics relevant to right-angle torque tool use. Powered torque tools are widely used to tighten fasteners in manufacturing industries. While these tools increase accuracy and efficiency of tightening processes, operators are repetitively exposed to impulsive forces, posing risk of upper extremity musculoskeletal injury. A novel testing apparatus was developed that closely mimics biomechanical exposure in torque tool operation. Forty experienced torque tool operators were tested with the apparatus to determine model parameters and validate the protocol for physical capacity assessment. A second-order hand-arm model with parameters extracted in the time domain met model accuracy criterion of 5% for time-to-peak displacement error in 93% of trials (vs. 75% for frequency domain). Average time-to-peak handle displacement and relative peak handle force errors were 0.69 ms and 0.21%, respectively. Model parameters were significantly affected by gender and working posture. Protocol and numerical calculation procedures provide an alternative method for assessing mechanical parameters relevant to right-angle torque tool use. The protocol more closely resembles tool use, and calculation procedures demonstrate better performance of parameter extraction using time domain system identification methods versus frequency domain. Potential future applications include parameter identification for in situ torque tool operation and equipment development for human hand-arm dynamics simulation under impulsive forces that could be used for assessing torque tools based on factors relevant to operator health (handle dynamics and hand-arm reaction force).
Power hand tool kinetics associated with upper limb injuries in an automobile assembly plant.
Ku, Chia-Hua; Radwin, Robert G; Karsh, Ben-Tzion
2007-06-01
This study investigated the relationship between pneumatic nutrunner handle reactions, workstation characteristics, and prevalence of upper limb injuries in an automobile assembly plant. Tool properties (geometry, inertial properties, and motor characteristics), fastener properties, orientation relative to the fastener, and the position of the tool operator (horizontal and vertical distances) were measured for 69 workstations using 15 different pneumatic nutrunners. Handle reaction response was predicted using a deterministic mechanical model of the human operator and tool that was previously developed in our laboratory, specific to the measured tool, workstation, and job factors. Handle force was a function of target torque, tool geometry and inertial properties, motor speed, work orientation, and joint hardness. The study found that tool target torque was not well correlated with predicted handle reaction force (r=0.495) or displacement (r=0.285). The individual tool, tool shape, and threaded fastener joint hardness all affected predicted forces and displacements (p<0.05). The average peak handle force and displacement for right-angle tools were twice as great as pistol grip tools. Soft-threaded fastener joints had the greatest average handle forces and displacements. Upper limb injury cases were identified using plant OSHA 200 log and personnel records. Predicted handle forces for jobs where injuries were reported were significantly greater than those jobs free of injuries (p<0.05), whereas target torque and predicted handle displacement did not show statistically significant differences. The study concluded that quantification of handle reaction force, rather than target torque alone, is necessary for identifying stressful power hand tool operations and for controlling exposure to forces in manufacturing jobs involving power nutrunners. Therefore, a combination of tool, work station, and task requirements should be considered.
Technical Errors May Affect Accuracy of Torque Limiter in Locking Plate Osteosynthesis.
Savin, David D; Lee, Simon; Bohnenkamp, Frank C; Pastor, Andrew; Garapati, Rajeev; Goldberg, Benjamin A
2016-01-01
In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P < .0001) different mean (SD) measurements: 1.49 (0.15) Nm and 3.73 (0.79) Nm. Use under drill power at controlled low velocity and at high velocity also resulted in significantly (P < .0001) different mean (SD) measurements: 1.47 (0.14) Nm and 5.37 (0.90) Nm. Maximum single measurement obtained was 9.0 Nm using drill power at high velocity. Locking screw insertion with improper technique may result in higher than expected torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.
Theoretical And Experimental Investigations On The Plasma Of A CO2 High Power Laser
NASA Astrophysics Data System (ADS)
Abel, W.; Wallter, B.
1984-03-01
The CO2 high power laser is increasingly used in material processing. This application of the laser has to meet some requirements: at one hand the laser is a tool free of wastage, but at the other hand is to guarantee that the properties of that tool are constant in time. Therefore power, geometry and mode of the beam have to be stable over long intervalls, even if the laser is used in rough industrial environment. Otherwise laser material processing would not be competitive. The beam quality is affected by all components of the laser - by the CO2 plasma and its IR - amplification, by the resonator which at last generates the beam by optical feedback, and also by the electric power supply whose effects on the plasma may be measured at the laser beam. A transversal flow laser has been developed at the Technical University of Vienna in cooperation with VOest-Alpine AG, Linz (Austria). This laser produces 1 kW of beam power with unfolded resonator. It was subject to investigations presented in this paper.
Simple circuit monitors "third wire" in ac lines
NASA Technical Reports Server (NTRS)
Kojima, T. T.; Stuck, D. E.
1980-01-01
Device detects interruption of ground connection in three-wire electrical equipment and shuts off ac power to prevent shock hazard. Silicon-controlled rectifiers detect floating ground, and deenergize optoelectric relays thereby breaking power connections. Circuit could be incorporated into hand tools, appliances, and other electrical equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Equipment. 367.57 Section 367.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT... equipment accounts hand and other portable tools, that are likely to be lost or stolen or that have...
Recommendations for tool-handle material choice based on finite element analysis.
Harih, Gregor; Dolšak, Bojan
2014-05-01
Huge areas of work are still done manually and require the usages of different powered and non-powered hand tools. In order to increase the user performance, satisfaction, and lower the risk of acute and cumulative trauma disorders, several researchers have investigated the sizes and shapes of tool-handles. However, only a few authors have investigated tool-handles' materials for further optimising them. Therefore, as presented in this paper, we have utilised a finite-element method for simulating human fingertip whilst grasping tool-handles. We modelled and simulated steel and ethylene propylene diene monomer (EPDM) rubber as homogeneous tool-handle materials and two composites consisting of EPDM rubber and EPDM foam, and also EPDM rubber and PU foam. The simulated finger force was set to obtain characteristic contact pressures of 20 kPa, 40 kPa, 80 kPa, and 100 kPa. Numerical tests have shown that EPDM rubber lowers the contact pressure just slightly. On the other hand, both composites showed significant reduction in contact pressure that could lower the risks of acute and cumulative trauma disorders which are pressure-dependent. Based on the results, it is also evident that a composite containing PU foam with a more evident and flat plateau deformed less at lower strain rates and deformed more when the plateau was reached, in comparison to the composite with EPDM foam. It was shown that hyper-elastic foam materials, which take into account the non-linear behaviour of fingertip soft tissue, can lower the contact pressure whilst maintaining low deformation rate of the tool-handle material for maintaining sufficient rate of stability of the hand tool in the hands. Lower contact pressure also lowers the risk of acute and cumulative trauma disorders, and increases comfort whilst maintaining performance. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Agriculture Education. Agriculture Structures.
ERIC Educational Resources Information Center
Stuttgart Public Schools, AR.
This curriculum guide is designed for group instruction of secondary agricultural education students enrolled in one or two semester-long courses in agriculture structures. The guide presents units of study in the following areas: (1) shop safety, (2) identification and general use of hand tools, (3) power tools, (4) carpentry, (5) blueprint…
Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…
Bilingual Vocational Training Program. Auto Body Repair. Module 2.0: Tools and Equipment.
ERIC Educational Resources Information Center
Northern New Mexico Community Coll., El Rito.
This module on tools and equipment is the second of four (CE 028 303-306) in the auto body repair course of a bilingual vocational training program. The course is designed to furnish theoretical and laboratory experience in welding, metal straightening, metal finishing, painting, and use of power and hand tools. Module objectives are for students…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-01
..., GA; Application for Manufacturing Authority; Makita Corporation of America (Hand-Held Power Tool and Gasoline/Electric-Powered Garden Product Manufacturing); Buford, GA An application has been submitted to..., requesting manufacturing authority on behalf of Makita Corporation of America (Makita), located in Buford...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
..., GA; Application for Temporary/ Interim Manufacturing Authority; Makita Corporation of America; (Hand- Held Power Tool and Gasoline/Electric-Powered Garden Product Manufacturing); Buford, GA An application... Georgia Foreign-Trade Zone, Inc., grantee of FTZ 26, requesting temporary/interim manufacturing (T/IM...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Docket T-2-2011] Foreign-Trade Zone 26, Temporary/Interim Manufacturing Authority, Makita Corporation of America, Hand-Held Power Tool and Gasoline/ Electric-Powered Garden Product Manufacturing; Notice of Approval On June 22, 2011, the Executive Secretary...
Energy evaluation of protection effectiveness of anti-vibration gloves.
Hermann, Tomasz; Dobry, Marian Witalis
2017-09-01
This article describes an energy method of assessing protection effectiveness of anti-vibration gloves on the human dynamic structure. The study uses dynamic models of the human and the glove specified in Standard No. ISO 10068:2012. The physical models of human-tool systems were developed by combining human physical models with a power tool model. The combined human-tool models were then transformed into mathematical models from which energy models were finally derived. Comparative energy analysis was conducted in the domain of rms powers. The energy models of the human-tool systems were solved using numerical simulation implemented in the MATLAB/Simulink environment. The simulation procedure demonstrated the effectiveness of the anti-vibration glove as a method of protecting human operators of hand-held power tools against vibration. The desirable effect is achieved by lowering the flow of energy in the human-tool system when the anti-vibration glove is employed.
Power System Electrician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4609
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2009
2009-01-01
The graduate of the Power System Electrician apprenticeship training is a journeyman who will be able to: (1) responsibly do all work tasks expected of a journeyman; (2) supervise, train and coach apprentices; (3) use and maintain hand and power tools to the standards of competency and safety required in the trade; (4) read and interpret drawing,…
Power and Energy: Industrial Arts Curriculum Guide. Grades 9-12. Curriculum Guide 1335 (Tentative).
ERIC Educational Resources Information Center
Louisiana State Dept. of Education, Baton Rouge.
The tentative guide in power and energy for senior high school use is part of a series of industrial arts curriculum materials developed by the State of Louisiana. The course is designed to provide "hands-on" experience with tools and materials along with a study of the industrial processes in power and energy. In addition, the student…
Tactile Gloves for Autonomous Grasping With the NASA/DARPA Robonaut
NASA Technical Reports Server (NTRS)
Martin, T. B.; Ambrose, R. O.; Diftler, M. A.; Platt, R., Jr.; Butzer, M. J.
2004-01-01
Tactile data from rugged gloves are providing the foundation for developing autonomous grasping skills for the NASA/DARPA Robonaut, a dexterous humanoid robot. These custom gloves compliment the human like dexterity available in the Robonaut hands. Multiple versions of the gloves are discussed, showing a progression in using advanced materials and construction techniques to enhance sensitivity and overall sensor coverage. The force data provided by the gloves can be used to improve dexterous, tool and power grasping primitives. Experiments with the latest gloves focus on the use of tools, specifically a power drill used to approximate an astronaut's torque tool.
46 CFR 197.420 - Operations manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... dive team. (b) The operations manual must be modified in writing when adaptation is required because of...) Hand-held power tools; (ii) Welding and burning equipment; and (iii) Explosives. specific diving mode...
Instructional Support System--Occupational Education. Building Industries Occupations.
ERIC Educational Resources Information Center
Abramson, Theodore; And Others
The modules which make up the bulk of this report are the result of a two-week workshop at which thirteen building industries occupations teachers worked toward the development of a student outcome oriented curriculum. These modules are divided into the following occupational units: (1) carpentry (containing hand tools; portable power tools;…
Bricklaying Curriculum: Principles of Bricklaying. Instructional Materials. Revised.
ERIC Educational Resources Information Center
Turcotte, Raymond J.; Hendrix, Laborn J.
This volume is the second in a two-volume core curriculum designed for use in teaching a course in bricklaying. Covered in the first four units are hand tools, power tools, miscellaneous equipment, and builder's levels. The second section of the guide comprises units on the following building materials: mortars, masonry units, and anchors and…
29 CFR 1926.302 - Power-operated hand tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the source of supply or branch line to reduce pressure in case of hose failure. (8) Airless spray guns... the open barrel end. (6) Loaded tools shall not be left unattended. (7) Fasteners shall not be driven...-hardened steel, glass block, live rock, face brick, or hollow tile. (8) Driving into materials easily...
29 CFR 1926.302 - Power-operated hand tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the source of supply or branch line to reduce pressure in case of hose failure. (8) Airless spray guns... the open barrel end. (6) Loaded tools shall not be left unattended. (7) Fasteners shall not be driven...-hardened steel, glass block, live rock, face brick, or hollow tile. (8) Driving into materials easily...
29 CFR 1926.302 - Power-operated hand tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the source of supply or branch line to reduce pressure in case of hose failure. (8) Airless spray guns... the open barrel end. (6) Loaded tools shall not be left unattended. (7) Fasteners shall not be driven...-hardened steel, glass block, live rock, face brick, or hollow tile. (8) Driving into materials easily...
29 CFR 1926.302 - Power-operated hand tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the source of supply or branch line to reduce pressure in case of hose failure. (8) Airless spray guns... the open barrel end. (6) Loaded tools shall not be left unattended. (7) Fasteners shall not be driven...-hardened steel, glass block, live rock, face brick, or hollow tile. (8) Driving into materials easily...
29 CFR 1926.302 - Power-operated hand tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the source of supply or branch line to reduce pressure in case of hose failure. (8) Airless spray guns... the open barrel end. (6) Loaded tools shall not be left unattended. (7) Fasteners shall not be driven...-hardened steel, glass block, live rock, face brick, or hollow tile. (8) Driving into materials easily...
Hand anthropometry of Indian women.
Nag, Anjali; Nag, P K; Desai, Hina
2003-06-01
Data on the physical dimension of the hand of Indian women are scanty. This information is necessary to ascertain human-machine compatibility in the design of manual systems for the bare and gloved hand, such as design and sizing of hand tools, controls, knobs and other applications in different kinds of precision and power grips. The present study was undertaken to generate hand anthropometric data of 95 women, working in informal industries (beedi, agarbatti and garment making). Fifty one hand measurements of the right hand (lengths, breadths, circumferences, depths, spreads and clearances of hand and fingers) were taken, using anthropometric sliding and spreading calipers, measuring tape and handgrip strength dynamometer. The data were statistically analyzed to determine the normality of data and the percentile values of different hand dimensions, and simple and multiple regression analysis were done to determine better predictors of hand length and grip strength. The hand breadths, circumferences and depths were approximately normally distributed, with some deviation in case of the finger lengths. Hand length was significantly correlated with the fist, wrist and finger circumferences. The fist and wrist circumferences, in combination, were better predictors of hand length. The hand lengths, breadths and depths, including finger joints of the Indian women studied were smaller than those of American, British and West Indian women. The hand circumferences of the Indian women were also smaller than the American women. Grip strengths of Indian women (20.36 +/- 3.24 kg) were less than those of American, British and West Indian women. Grip strength was found to be statistically significant with hand dimensions, such as hand height perpendicular to wrist crease (digit 5), proximal interphalangeal joint breadth (digit 3) and hand spread across wedge 1. The women who are forced to frequently use cutters, strippers and other tools, which are not optimally designed to their hand dimensions and strength range, might have higher prevalence of clinical symptoms and disorders of the hand. In view of the human hand-tool interface requirements, the present data on Indian women would be useful for ergo-design applications of hand tools and devices.
Biodynamic response at the palm of the human hand subjected to a random vibration.
Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E
2005-01-01
This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system resonated mostly in the frequency range of 20 to 50 Hz, depending on the specific test treatment and individual characteristics. The maximum vibration power transmission through the palm occurred at the resonant frequency. Increasing the effective palm force generally increased the BR magnitude and resonant frequency. The apparent stiffness measured at the middle frequencies (80-100 Hz) is correlated to the BR in almost the entire frequency range (20-1,000 Hz). Under the same palm force, the push-only action corresponded to the highest BR values while the grip-only action generally produced the lowest values. Since the resonant frequency range matches the dominant vibration frequency range of many percussive tools, it is anticipated that the palm BR and vibration power transmission may have an association with vibration-induced injuries or disorders in the wrist-arm system among the workers using these tools.
Vibration and impulsivity analysis of hand held olive beaters.
Deboli, Roberto; Calvo, Angela; Preti, Christian
2016-07-01
To provide more effective evaluations of hand arm vibration syndromes caused by hand held olive beaters, this study focused on two aspects: the acceleration measured at the tool pole and the analysis of the impulsivity, using the crest factor. The signals were frequency weighted using the weighting curve Wh as described in the ISO 5349-1 standard. The same source signals were also filtered by the Wh-bl filter (ISO/TS 15694), because the weighting filter Wh (unlike the Wh-bl filter) could underestimate the effect of high frequency vibration on vibration-induced finger disorders. Ten (experienced) male operators used three beater models (battery powered) in the real olive harvesting condition. High vibration total values were obtained with values never lower than 20 m(-2). Concerning the crest factor, the values ranged from 5 to more than 22. This work demonstrated that the hand held olive beaters produced high impulsive loads comparable to the industry hand held tools. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Abd El Basset Bakr, Ashraf Mohamed; Hasaneen, Bothina Mohamed; AbdelRasoul Helal Bassiouni, Dina
2018-05-03
Muscle status assessment is crucial for diagnosis of protein energy wasting PEW/cachexia in chronic kidney disease (CKD) population. Hand grip strength (HGS) has been used in muscle power assessment in adult CKD. However, no data is available about its usefulness in children with CKD. Hence, we aimed to study the reliability of HGS in reflecting the muscle power and thus, nutritional status in children with CKD. In this Observational cross sectional study we enrolled 73 CKD children; 45 had end stage kidney disease (ESKD) on hemodialysis (HD) and 28 had CKD but not on dialysis yet. Assessment of children's nutritional status was done through biochemical variables (serum albumin and serum cholesterol) and anthropometric measures (height and BMI). Body composition monitor (BCM) device was used for lean tissue mass (LTM) assessment whilst muscle power was tested by HGS tool. The study showed that 69.8% of CKD patients had HGS values below 10th percentile for age and sex. Moreover, HGS was observed to be more affected in CRI patients and those with non - glomerular causes. HGS was also found to be positively correlated to height but not to lean tissue mass or serum albumin. HGS tool can be used as a reliable bedside tool for nutritional assessment in children with CKD. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Loads produced by a suited subject performing tool tasks without the use of foot restraints
NASA Technical Reports Server (NTRS)
Rajulu, Sudhakar L.; Poliner, Jeffrey; Klute, Glenn K.
1993-01-01
With an increase in the frequency of extravehicular activities (EVA's) aboard the Space Shuttle, NASA is interested in determining the capabilities of suited astronauts while performing manual tasks during an EVA, in particular the situations in which portable foot restraints are not used to stabilize the astronauts. Efforts were made to document the forces that are transmitted to spacecraft while pushing and pulling an object as well as while operating a standard wrench and an automatic power tool. The six subjects studied aboard the KC-135 reduced gravity aircraft were asked to exert a maximum torque and to maintain a constant level of torque with a wrench, to push and pull an EVA handrail, and to operate a Hubble Space Telescope (HST) power tool. The results give an estimate of the forces and moments that an operator will transmit to the handrail as well as to the supporting structure. In general, it was more effective to use the tool inwardly toward the body rather than away from the body. There were no differences in terms of strength capabilities between right and left hands. The power tool was difficult to use. It is suggested that ergonomic redesigning of the power tool may increase the efficiency of power tool use.
Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head.
Xu, Xueyan S; Dong, Ren G; Welcome, Daniel E; Warren, Christopher; McDowell, Thomas W; Wu, John Z
2017-12-01
Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7-12 Hz, the shoulder resonance was 7-9 Hz, and the back and neck resonances were 6-7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods.
Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head
Xu, Xueyan S.; Dong, Ren G.; Welcome, Daniel E.; Warren, Christopher; McDowell, Thomas W.; Wu, John Z.
2016-01-01
Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7–12 Hz, the shoulder resonance was 7–9 Hz, and the back and neck resonances were 6–7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. Relevance to industry Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods. PMID:29123326
Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.
2008-01-01
Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574
Trombert-Paviot, B; Rodrigues, J M; Rogers, J E; Baud, R; van der Haring, E; Rassinoux, A M; Abrial, V; Clavel, L; Idir, H
1999-01-01
GALEN has developed a new generation of terminology tools based on a language independent concept reference model using a compositional formalism allowing computer processing and multiple reuses. During the 4th framework program project Galen-In-Use we applied the modelling and the tools to the development of a new multipurpose coding system for surgical procedures (CCAM) in France. On one hand we contributed to a language independent knowledge repository for multicultural Europe. On the other hand we support the traditional process for creating a new coding system in medicine which is very much labour consuming by artificial intelligence tools using a medically oriented recursive ontology and natural language processing. We used an integrated software named CLAW to process French professional medical language rubrics produced by the national colleges of surgeons into intermediate dissections and to the Grail reference ontology model representation. From this language independent concept model representation on one hand we generate controlled French natural language to support the finalization of the linguistic labels in relation with the meanings of the conceptual system structure. On the other hand the classification manager of third generation proves to be very powerful to retrieve the initial professional rubrics with different categories of concepts within a semantic network.
Validity and inter-observer reliability of subjective hand-arm vibration assessments.
Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen
2014-07-01
Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Watson, Robert A
2014-08-01
To test the hypothesis that machine learning algorithms increase the predictive power to classify surgical expertise using surgeons' hand motion patterns. In 2012 at the University of North Carolina at Chapel Hill, 14 surgical attendings and 10 first- and second-year surgical residents each performed two bench model venous anastomoses. During the simulated tasks, the participants wore an inertial measurement unit on the dorsum of their dominant (right) hand to capture their hand motion patterns. The pattern from each bench model task performed was preprocessed into a symbolic time series and labeled as expert (attending) or novice (resident). The labeled hand motion patterns were processed and used to train a Support Vector Machine (SVM) classification algorithm. The trained algorithm was then tested for discriminative/predictive power against unlabeled (blinded) hand motion patterns from tasks not used in the training. The Lempel-Ziv (LZ) complexity metric was also measured from each hand motion pattern, with an optimal threshold calculated to separately classify the patterns. The LZ metric classified unlabeled (blinded) hand motion patterns into expert and novice groups with an accuracy of 70% (sensitivity 64%, specificity 80%). The SVM algorithm had an accuracy of 83% (sensitivity 86%, specificity 80%). The results confirmed the hypothesis. The SVM algorithm increased the predictive power to classify blinded surgical hand motion patterns into expert versus novice groups. With further development, the system used in this study could become a viable tool for low-cost, objective assessment of procedural proficiency in a competency-based curriculum.
Exposure assessment in health assessments for hand-arm vibration syndrome.
Mason, H J; Poole, K; Young, C
2011-08-01
Assessing past cumulative vibration exposure is part of assessing the risk of hand-arm vibration syndrome (HAVS) in workers exposed to hand-arm vibration and invariably forms part of a medical assessment of such workers. To investigate the strength of relationships between the presence and severity of HAVS and different cumulative exposure metrics obtained from a self-reporting questionnaire. Cumulative exposure metrics were constructed from a tool-based questionnaire applied in a group of HAVS referrals and workplace field studies. These metrics included simple years of vibration exposure, cumulative total hours of all tool use and differing combinations of acceleration magnitudes for specific tools and their daily use, including the current frequency-weighting method contained in ISO 5349-1:2001. Use of simple years of exposure is a weak predictor of HAVS or its increasing severity. The calculation of cumulative hours across all vibrating tools used is a more powerful predictor. More complex calculations based on involving likely acceleration data for specific classes of tools, either frequency weighted or not, did not offer a clear further advantage in this dataset. This may be due to the uncertainty associated with workers' recall of their past tool usage or the variability between tools in the magnitude of their vibration emission. Assessing years of exposure or 'latency' in a worker should be replaced by cumulative hours of tool use. This can be readily obtained using a tool-pictogram-based self-reporting questionnaire and a simple spreadsheet calculation.
29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.
Code of Federal Regulations, 2011 CFR
2011-07-01
... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...
29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.
Code of Federal Regulations, 2012 CFR
2012-07-01
... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...
29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.
Code of Federal Regulations, 2013 CFR
2013-07-01
... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...
29 CFR 570.34 - Occupations that may be performed by minors 14 and 15 years of age.
Code of Federal Regulations, 2014 CFR
2014-07-01
... comparative shopping. (e) Price marking and tagging by hand or machine, assembling orders, packing, and... machines shall mean all fixed or portable machines or tools driven by power and used or designed for...
29 CFR 1926.300 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Personal protective equipment. Employees using hand and power tools and exposed to the hazard of falling... shall be provided with the particular personal protective equipment necessary to protect them from the hazard. All personal protective equipment shall meet the requirements and be maintained according to...
29 CFR 1926.300 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Personal protective equipment. Employees using hand and power tools and exposed to the hazard of falling... shall be provided with the particular personal protective equipment necessary to protect them from the hazard. All personal protective equipment shall meet the requirements and be maintained according to...
Shibata, Nobuyuki; Hosoya, Naoki; Maeda, Setsuo
2008-12-01
Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s2)2/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the basis of the results obtained in this study, we conclude that this hand-arm vibration test system can be used to measure biodynamic response parameters of the human hand-arm system.
Milosevic, Matija; McConville, Kristiina M Valter
2012-01-01
Operation of handheld power tools results in exposure to hand-arm vibrations, which over time lead to numerous health complications. The objective of this study was to evaluate protective equipment and working techniques for the reduction of vibration exposure. Vibration transmissions were recorded during different work techniques: with one- and two-handed grip, while wearing protective gloves (standard, air and anti-vibration gloves) and while holding a foam-covered tool handle. The effect was examined by analyzing the reduction of transmitted vibrations at the wrist. The vibration transmission was recorded with a portable device using a triaxial accelerometer. The results suggest large and significant reductions of vibration with appropriate safety equipment. Reductions of 85.6% were achieved when anti-vibration gloves were used. Our results indicated that transmitted vibrations were affected by several factors and could be measured and significantly reduced.
ERIC Educational Resources Information Center
Air Force Training Command, Sheppard AFB, TX.
This instructional package is intended for use in training Air Force personnel enrolled in a program for apprentice carpenters. Training includes an introduction to carpentry and provides instruction in the use of carpentry hand, portable power, and shop tools; construction and maintenance of wood structures; installation of building hardware; and…
Stone, John E.; Hynninen, Antti-Pekka; Phillips, James C.; Schulten, Klaus
2017-01-01
All-atom molecular dynamics simulations of biomolecules provide a powerful tool for exploring the structure and dynamics of large protein complexes within realistic cellular environments. Unfortunately, such simulations are extremely demanding in terms of their computational requirements, and they present many challenges in terms of preparation, simulation methodology, and analysis and visualization of results. We describe our early experiences porting the popular molecular dynamics simulation program NAMD and the simulation preparation, analysis, and visualization tool VMD to GPU-accelerated OpenPOWER hardware platforms. We report our experiences with compiler-provided autovectorization and compare with hand-coded vector intrinsics for the POWER8 CPU. We explore the performance benefits obtained from unique POWER8 architectural features such as 8-way SMT and its value for particular molecular modeling tasks. Finally, we evaluate the performance of several GPU-accelerated molecular modeling kernels and relate them to other hardware platforms. PMID:29202130
ERIC Educational Resources Information Center
Air Force Training Command, Sheppard AFB, TX.
This instructional package is intended for use in training Air Force personnel enrolled in a program for apprentice masons. Training includes an introduction to masonry and provides instruction in the use of masons' hand, portable power, and shop tools; construction and maintenance of masonry structures using brick, concrete block, and tile;…
Landscape Management: Field Operator.
ERIC Educational Resources Information Center
Smith, Carole A.
These materials for a six-unit course were developed to prepare secondary and postsecondary students for entry-level positions in landscape management. The six units are on orientation, hand tools, light power equipment, water and watering techniques, planting and maintaining plant beds, and establishing and maintaining turf. The first section is…
Introduction to Horticulture. Teacher Edition. Horticulture Series.
ERIC Educational Resources Information Center
Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
This publication is designed to provide a core of instruction for the many different fields in agricultural/horticultural education. This course contains 21 instructional units that cover the following topics: introduction to horticulture; beginning a career in horticulture; hand and power tools; introduction to safety; growing facilities;…
Aviation Maintenance Technology. General. G104 Technical Mechanics. Instructor Material.
ERIC Educational Resources Information Center
Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
These instructor materials for an aviation maintenance technology course contain five instructional modules. The modules cover the following topics: performing aircraft ground handling and servicing, using hand and power tools and precision measuring instruments, identifying and selecting aircraft hardware, fabricating and installing rigid and…
Mukherjee, Joydeep; Llewellyn, Lyndon E; Evans-Illidge, Elizabeth A
2008-01-01
Microbial marine biodiscovery is a recent scientific endeavour developing at a time when information and other technologies are also undergoing great technical strides. Global visualisation of datasets is now becoming available to the world through powerful and readily available software such as Worldwind™, ArcGIS Explorer™ and Google Earth™. Overlaying custom information upon these tools is within the hands of every scientist and more and more scientific organisations are making data available that can also be integrated into these global visualisation tools. The integrated global view that these tools enable provides a powerful desktop exploration tool. Here we demonstrate the value of this approach to marine microbial biodiscovery by developing a geobibliography that incorporates citations on tropical and near-tropical marine microbial natural products research with Google Earth™ and additional ancillary global data sets. The tools and software used are all readily available and the reader is able to use and install the material described in this article. PMID:19172194
[The hand-arm vibration syndrome: (II). The diagnostic aspects and fitness criteria].
Bovenzi, M
1999-01-01
Part II of this paper reviews the clinical and laboratory methods to diagnose the neurological, vascular and osteoarticular components of the hand-arm vibration syndrome. The prognosis and reversibility of vibration-induced neurological and vascular disorders after cessation of vibration exposure or the introduction of powered tools equipped with vibration isolation systems are discussed on the basis of the results of follow-up clinical investigations and longitudinal epidemiologic studies. Finally, the review debates some of the methodological aspects connected with the health surveillance of vibration-exposed workers and considers the possible medical contra-indications for prolonged exposure to hand-transmitted vibration.
Identifying factors of comfort in using hand tools.
Kuijt-Evers, L F M; Groenesteijn, L; de Looze, M P; Vink, P
2004-09-01
To design comfortable hand tools, knowledge about comfort/discomfort in using hand tools is required. We investigated which factors determine comfort/discomfort in using hand tools according to users. Therefore, descriptors of comfort/discomfort in using hand tools were collected from literature and interviews. After that, the relatedness of a selection of the descriptors to comfort in using hand tools was investigated. Six comfort factors could be distinguished (functionality, posture and muscles, irritation and pain of hand and fingers, irritation of hand surface, handle characteristics, aesthetics). These six factors can be classified into three meaningful groups: functionality, physical interaction and appearance. The main conclusions were that (1) the same descriptors were related to comfort and discomfort in using hand tools, (2) descriptors of functionality are most related to comfort in using hand tools followed by descriptors of physical interaction and (3) descriptors of appearance become secondary in comfort in using hand tools.
Dong, Ren G; Dong, Jennie H; Wu, John Z; Rakheja, Subhash
2007-01-01
The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fingers-handle and palm-handle interfaces, as opposed to the single driving point invariably considered in the reported models. The parameters of the proposed four- and five degrees-of-freedom models are identified through minimization of an rms error function of the model and measured responses under different hand actions, namely, fingers pull, push only, grip only, and combined push and grip. The results show that the responses predicted from both models agree reasonably well with the measured data in terms of distributed as well total impedance magnitude and phase. The variations in the identified model parameters under different hand actions are further discussed in view of the biological system behavior. The proposed models are considered to serve as useful tools for design and assessment of vibration isolation methods, and for developing a hand-arm simulator for vibration analysis of power tools.
DESIGN OF A SMALL – SCALE SOLAR CHIMNEY FOR SUSTAINABLE POWER
After several months of design and testing it has been determined that a small scale solar chimney can be built using nearly any local materials and simple hand tools without needing superior construction knowledge. The biggest obstacle to over come was the weather conditions....
29 CFR 1926.306 - Air receivers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 8 2014-07-01 2014-07-01 false Air receivers. 1926.306 Section 1926.306 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.306 Air receivers. (a) General requirements—(1) Application. This section applies to compressed air receivers, and other equipment used in...
29 CFR 1926.306 - Air receivers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 8 2012-07-01 2012-07-01 false Air receivers. 1926.306 Section 1926.306 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.306 Air receivers. (a) General requirements—(1) Application. This section applies to compressed air receivers, and other equipment used in...
29 CFR 1926.306 - Air receivers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 8 2013-07-01 2013-07-01 false Air receivers. 1926.306 Section 1926.306 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.306 Air receivers. (a) General requirements—(1) Application. This section applies to compressed air receivers, and other equipment used in...
29 CFR 1926.306 - Air receivers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 8 2010-07-01 2010-07-01 false Air receivers. 1926.306 Section 1926.306 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.306 Air receivers. (a) General requirements—(1) Application. This section applies to compressed air receivers, and other equipment used in...
29 CFR 1926.306 - Air receivers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 8 2011-07-01 2011-07-01 false Air receivers. 1926.306 Section 1926.306 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.306 Air receivers. (a) General requirements—(1) Application. This section applies to compressed air receivers, and other equipment used in...
Lecture-Free High School Biology Using an Audience Response System
ERIC Educational Resources Information Center
Barnes, Larry J.
2008-01-01
Audience Response Systems (ARS) represent a powerful new tool for increasing student engagement. ARS technology (known variously as electronic voting systems, personal response systems, interactive student response systems, and classroom performance systems) includes one hand-held remote per student, a receiver (infrared or radio frequency,…
ERIC Educational Resources Information Center
Smith, Dwight; And Others
This instructional package is one of two designed for regular vocational students in the vocational area of building maintenance and engineering. The fifty-three learning modules are organized into ten units: office cleaning; grounds; sanitation; boiler maintenance and operation; power and hand tools; cabinet construction; repair of damaged…
Commercial Carpentry: Instructional Units. INST-BBB08691;BBB12485
ERIC Educational Resources Information Center
Diehl, Donald W.; Penner, Wayman R.
The guide contains 11 sections, each consisting of one or more units of instruction in commercial carpentry. The sections cover the following: introduction (orientation, safety, and applying for a job), leadership, related information (lumber, measuring, and fasteners), power and hand tools, blueprint reading, site preparation and layout, forming,…
A GUIDE FOR EQUIPPING INDUSTRIAL ARTS FACILITIES.
ERIC Educational Resources Information Center
American Industrial Arts Association, Washington, DC. Equipment Guide Committee.
SCHOOL ARCHITECTS, ADMINISTRATORS, PLANNERS, AND INDUSTRIAL ARTS SUPERVISORS AND TEACHERS MAY USE THIS GUIDE IN PLANNING, REVISING, AND EVALUATING FACILITIES. IN THE FIRST PART, HAND TOOLS, MACHINES, AND GENERAL EQUIPMENT ARE LISTED FOR (1) AUTO AND POWER MECHANICS, (2) CERAMICS, (3) DRAFTING, (4) ELECTRICITY-ELECTRONICS, (5) ELEMENTARY, (6)…
Lausberg, Hedda; Kazzer, Philipp; Heekeren, Hauke R; Wartenburger, Isabell
2015-10-01
Neuropsychological lesion studies evidence the necessity to differentiate between various forms of tool-related actions such as real tool use, tool use demonstration with tool in hand and without physical target object, and pantomime without tool in hand. However, thus far, neuroimaging studies have primarily focused only on investigating tool use pantomimes. The present fMRI study investigates pantomime without tool in hand as compared to tool use demonstration with tool in hand in order to explore patterns of cerebral signal modulation associated with acting with imaginary tools in hand. Fifteen participants performed with either hand (i) tool use pantomime with an imaginary tool in hand in response to visual tool presentation and (ii) tool use demonstration with tool in hand in response to visual-tactile tool presentation. In both conditions, no physical target object was present. The conjunction analysis of the right and left hands executions of tool use pantomime relative to tool use demonstration yielded significant activity in the left middle and superior temporal lobe. In contrast, demonstration relative to pantomime revealed large bihemispherically distributed homologous areas of activity. Thus far, fMRI studies have demonstrated the relevance of the left middle and superior temporal gyri in viewing, naming, and matching tools and related actions and contexts. Since in our study all these factors were equally (ir)relevant both in the tool use pantomime and the tool use demonstration conditions, the present findings enhance the knowledge about the function of these brain regions in tool-related cognitive processes. The two contrasted conditions only differ regarding the fact that the pantomime condition requires the individual to act with an imaginary tool in hand. Therefore, we suggest that the left middle and superior temporal gyri are specifically involved in integrating the projected mental image of a tool in the execution of a tool-specific movement concept. Copyright © 2015 Elsevier Ltd. All rights reserved.
Helmich, Ingo; Holle, Henning; Rein, Robert; Lausberg, Hedda
2015-04-01
Divergent findings exist whether left and right hemispheric pre- and postcentral cortices contribute to the production of tool use related hand movements. In order to clarify the neural substrates of tool use demonstrations with tool in hand, tool use pantomimes without tool in hand, and body-part-as-object presentations of tool use (BPO) in a naturalistic mode of execution, we applied functional Near InfraRed Spectroscopy (fNIRS) in twenty-three right-handed participants. Functional NIRS techniques allow for the investigation of brain oxygenation during the execution of complex hand movements with an unlimited movement range. Brain oxygenation patterns were retrieved from 16 channels of measurement above pre- and postcentral cortices of each hemisphere. The results showed that tool use demonstration with tool in hand leads to increased oxygenation as compared to tool use pantomimes in the left hemispheric somatosensory gyrus. Left hand executions of the demonstration of tool use, pantomime of tool use, and BPO of tool use led to increased oxygenation in the premotor and somatosensory cortices of the left hemisphere as compared to right hand executions of either condition. The results indicate that the premotor and somatosensory cortices of the left hemisphere constitute relevant brain structures for tool related hand movement production when using the left hand, whereas the somatosensory cortex of the left hemisphere seems to provide specific mental representations when performing tool use demonstrations with the tool in hand. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Guirguis, Kamal; Price, Daniel S.
1990-01-01
Hand-held power tool shaves excess metal from inside circumference of welded duct. Removes excess metal deposited by penetration of tungsten/inert-gas weld or by spatter from electron-beam weld. Produces smooth transition across joint. Easier to use and not prone to overshaving. Also cuts faster, removing 35 in. (89 cm) of weld bead per hour.
Cabinetmaker: Apprenticeship Course Outline. Apprenticeship and Industry Training. 3610.3
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2010
2010-01-01
The graduate of the Cabinetmaker apprenticeship program is a certified journeyperson who will: (1)know the characteristics of wood, wood products or substitutes used in industrial woodworking; (2) be proficient with the safe use of hand tools, powered machines and equipment used in industrial woodworking; (3) read and interpret plans and…
Specifications of the High-Flux Solar Furnace | Concentrating Solar Power |
Non-imaging compound parabolic Acceptance angle: 14 degrees Entrance diameter: 6 cm Exit diameter secondary concentrator configurations are possible depending on the experimental needs. Back to top XYZ controllers ranging from 2,000 to 30,000 sccm Exhaust hood above experimental area Drill press and hand tools
Development and Evaluation of a Mass Conservation Laboratory Module in a Microfluidics Environment
ERIC Educational Resources Information Center
King, Andrew C.; Hidrovo, Carlos H.
2015-01-01
Laboratory-based instruction is a powerful educational tool that engages students in Science, Technology, Engineering and Mathematics (STEM) disciplines beyond textbook theory. This is true in mechanical engineering education and is often used to provide collegiate-level students a hands-on alternative to course theory. Module-based laboratory…
ERIC Educational Resources Information Center
Steinberg, Alan; And Others
This instructional package is one of three designed for educable mentally impaired students in the vocational area of building maintenance and engineering. The thirty-one learning modules are organized into nine units: grounds; sanitation; boiler maintenance and operation; power and hand tools; cabinet construction; repair of damaged furniture;…
Software Comparison for Renewable Energy Deployment in a Distribution Network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, David Wenzhong; Muljadi, Eduard; Tian, Tian
The main objective of this report is to evaluate different software options for performing robust distributed generation (DG) power system modeling. The features and capabilities of four simulation tools, OpenDSS, GridLAB-D, CYMDIST, and PowerWorld Simulator, are compared to analyze their effectiveness in analyzing distribution networks with DG. OpenDSS and GridLAB-D, two open source software, have the capability to simulate networks with fluctuating data values. These packages allow the running of a simulation each time instant by iterating only the main script file. CYMDIST, a commercial software, allows for time-series simulation to study variations on network controls. PowerWorld Simulator, another commercialmore » tool, has a batch mode simulation function through the 'Time Step Simulation' tool, which obtains solutions for a list of specified time points. PowerWorld Simulator is intended for analysis of transmission-level systems, while the other three are designed for distribution systems. CYMDIST and PowerWorld Simulator feature easy-to-use graphical user interfaces (GUIs). OpenDSS and GridLAB-D, on the other hand, are based on command-line programs, which increase the time necessary to become familiar with the software packages.« less
[A case with apraxia of tool use: selective inability to form a hand posture for a tool].
Hayakawa, Yuko; Fujii, Toshikatsu; Yamadori, Atsushi; Meguro, Kenichi; Suzuki, Kyoko
2015-03-01
Impaired tool use is recognized as a symptom of ideational apraxia. While many studies have focused on difficulties in producing gestures as a whole, using tools involves several steps; these include forming hand postures appropriate for the use of certain tool, selecting objects or body parts to act on, and producing gestures. In previously reported cases, both producing and recognizing hand postures were impaired. Here we report the first case showing a selective impairment of forming hand postures appropriate for tools with preserved recognition of the required hand postures. A 24-year-old, right-handed man was admitted to hospital because of sensory impairment of the right side of the body, mild aphasia, and impaired tool use due to left parietal subcortical hemorrhage. His ability to make symbolic gestures, copy finger postures, and orient his hand to pass a slit was well preserved. Semantic knowledge for tools and hand postures was also intact. He could flawlessly select the correct hand postures in recognition tasks. He only demonstrated difficulties in forming a hand posture appropriate for a tool. Once he properly grasped a tool by trial and error, he could use it without hesitation. These observations suggest that each step of tool use should be thoroughly examined in patients with ideational apraxia.
NASA Astrophysics Data System (ADS)
Eliazar, Iddo
2016-07-01
The study of socioeconomic inequality is of substantial importance, scientific and general alike. The graphic visualization of inequality is commonly conveyed by Lorenz curves. While Lorenz curves are a highly effective statistical tool for quantifying the distribution of wealth in human societies, they are less effective a tool for the visual depiction of socioeconomic inequality. This paper introduces an alternative to Lorenz curves-the hill curves. On the one hand, the hill curves are a potent scientific tool: they provide detailed scans of the rich-poor gaps in human societies under consideration, and are capable of accommodating infinitely many degrees of freedom. On the other hand, the hill curves are a powerful infographic tool: they visualize inequality in a most vivid and tangible way, with no quantitative skills that are required in order to grasp the visualization. The application of hill curves extends far beyond socioeconomic inequality. Indeed, the hill curves are highly effective 'hyperspectral' measures of statistical variability that are applicable in the context of size distributions at large. This paper establishes the notion of hill curves, analyzes them, and describes their application in the context of general size distributions.
Grasping with mechanical intelligence. M.S. Thesis
NASA Technical Reports Server (NTRS)
Ulrich, Nathan Thatcher
1988-01-01
Many robotic hands have been designed and a number have been built. Because of the difficulty of controlling and using complex hands, which usually have nine or more degrees of freedom, the simple one- or two-degree-of-freedom gripper is still the most common robotic end effector. A new category of device is presented: a medium-complexity end effector. With three to five degrees of freedom, such a tool is much easier to control and use, as well as more economical, compact and lightweight than complex hands. In order to increase the versatility, it was necessary to identify grasping primitives and to implement them in the mechanism. In addition, power and enveloping grasps are stressed over fingertip and precision grasps. The design is based upon analysis of object apprehension types, requisite characteristics for active sensing, and a determination of necessary environmental interactions. Contained are the general concepts necessary to the design of a medium-complexity end effector, an analysis of typical performance, and a computer simulation of a grasp planning algorithm specific to this type of mechanism. Finally, some details concerning the UPenn Hand-a tool designed for the research laboratory-are presented.
ERIC Educational Resources Information Center
Rodekohr, Sherie; Waeckerle, Debi
This instructor guide and the corresponding student reference contain 12 units, which cover the following topics: (1) opportunities in the landscaping and turfgrass industries; (2) how plants grow; (3) plant identification; (4) hand and power tools (identification and maintenance); (5) pesticides; (6) installation and maintenance of trees and…
Sawfiler: Apprenticeship Course Outline. Apprenticeship and Industry Training. 4406.3
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2006
2006-01-01
The graduate of the Sawfiler apprenticeship program is a certified journeyperson who will be able to: (1) responsibly do all work tasks expected of a journeyperson; (2) supervise, train and coach apprentices; (3) have a thorough knowledge of trade terminology; (4) use with safety and competence the hand and power tools commonly used in the trade;…
ERIC Educational Resources Information Center
Albright, Jessica C.; Dassenko, David J.; Mohamed, Essa A.; Beussman, Douglas J.
2009-01-01
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important bioanalytical technique in drug discovery, proteomics, and research at the biology-chemistry interface. This is an especially powerful tool when combined with gel separation of proteins and database mining using the mass spectral data. Currently, few hands-on…
Powerline Technician: Apprenticeship Course Outline. Apprenticeship and Industry Training. 2104.4
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2004
2004-01-01
The graduate of the Powerline Technician apprenticeship program is a certified journeyperson who will be able to: (1) responsibly do all work tasks expected of a journeyperson; (2) supervise, train and coach apprentices; (3) use and maintain hand and power tools to the standards of competency and safety required in the trade; (4) construct,…
3-d finite element model development for biomechanics: a software demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollerbach, K.; Hollister, A.M.; Ashby, E.
1997-03-01
Finite element analysis is becoming an increasingly important part of biomechanics and orthopedic research, as computational resources become more powerful, and data handling algorithms become more sophisticated. Until recently, tools with sufficient power did not exist or were not accessible to adequately model complicated, three-dimensional, nonlinear biomechanical systems. In the past, finite element analyses in biomechanics have often been limited to two-dimensional approaches, linear analyses, or simulations of single tissue types. Today, we have the resources to model fully three-dimensional, nonlinear, multi-tissue, and even multi-joint systems. The authors will present the process of developing these kinds of finite element models,more » using human hand and knee examples, and will demonstrate their software tools.« less
Mechanical energy and power flow of the upper extremity in manual wheelchair propulsion.
Guo, Lan-Yuen; Su, Fong-Chin; Wu, Hong-Wen; An, Kai-Nan
2003-02-01
To investigate the characteristics of mechanical energy and power flow of the upper limb during wheelchair propulsion. Mechanical energy and power flow of segments were calculated. Very few studies have taken into account the mechanical energy and power flow of the musculoskeletal system during wheelchair propulsion. Mechanical energy and power flow have proven to be useful tools for investigating locomotion disorders during human gait. Twelve healthy male adults (mean age, 23.5 years) were recruited for this study. Three-dimensional kinematic and kinetic data of the upper extremity were collected during wheelchair propulsion using a Hi-Res Expert Vision system and an instrumented wheel, respectively. During the initiation of the propulsion phase, joint power is generated in the upper arm or is transferred from the trunk downward to the forearm and hand to propel the wheel forward. During terminal propulsion, joint power is transferred upward to the trunk from the forearm and upper arm. The rate of change of mechanical energy and power flow for the forearm and hand have similar patterns, but the upper arm values differ. Joint power plays an important role in energy transfer as well as the energy generated and absorbed by muscles spanning the joints during wheelchair propulsion. Energy and power flow information during wheelchair propulsion allows us to gain a better understanding of the coordination of the movement by the musculoskeletal system.
The effects of vibration-reducing gloves on finger vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2015-01-01
Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new results and knowledge can be used to help select appropriate gloves for the operations of powered hand tools, to help perform risk assessment of the vibration exposure, and to help design better VR gloves. PMID:26543297
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
30 CFR 57.12033 - Hand-held electric tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...
Construction safety in DOE. Part 1, Students guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Handwerk, E C
This report is the first part of a compilation of safety standards for construction activities on DOE facilities. This report covers the following areas: general safety and health provisions; occupational health and environmental control/haz mat; personal protective equipment; fire protection and prevention; signs, signals, and barricades; materials handling, storage, use, and disposal; hand and power tools; welding and cutting; electrical; and scaffolding.
Taking Nanomedicine Teaching into Practice with Atomic Force Microscopy and Force Spectroscopy
ERIC Educational Resources Information Center
Carvalho, Filomena A.; Freitas, Teresa; Santos, Nuno C.
2015-01-01
Atomic force microscopy (AFM) is a useful and powerful tool to study molecular interactions applied to nanomedicine. The aim of the present study was to implement a hands-on atomic AFM course for graduated biosciences and medical students. The course comprises two distinct practical sessions, where students get in touch with the use of an atomic…
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2007
2007-01-01
The graduate of the Appliance Service Technician apprenticeship program is a certified journeyperson who will be able to: (1) responsibly do all work tasks expected of a journeyperson; (2) supervise, train and coach apprentices; (3) use and maintain hand and power tools to the standards of competency and safety required in the trade; (4) by skill…
ERIC Educational Resources Information Center
Alberta Advanced Education and Technology, 2011
2011-01-01
The graduate of the Refrigeration and Air Conditioning Mechanic apprenticeship training is a journeyman who will: (1) supervise, train and coach apprentices; (2) use and maintain hand and power tools to the standards of competency and safety required in the trade; (3) have a thorough knowledge of the principle components of refrigeration systems,…
Bilingual Skills Training Program. Auto Body Repair. Module 3.0: Basic Metal Repair.
ERIC Educational Resources Information Center
Northern New Mexico Community Coll., El Rito.
This module on basic metal repair is the third of four (CE 028 303-306) in the auto body repair course of a bilingual vocational training program. The course is designed to furnish theoretical and laboratory experience in welding, metal straightening, metal finishing, painting, and use of power and hand tools. Module objectives are for students to…
ERIC Educational Resources Information Center
van Pelt, James Clement
2011-01-01
As a scientist, Michael Polanyi made significant advances in chemistry and economics. From that deep hands-on experience, he derived a powerful critique of prevailing ideas of knowledge and the proper role of science. He demonstrated that disregarding or eliminating the personal embodiment of knowing in the tacit dimension in pursuit of purely…
Scaling forecast models for wind turbulence and wind turbine power intermittency
NASA Astrophysics Data System (ADS)
Duran Medina, Olmo; Schmitt, Francois G.; Calif, Rudy
2017-04-01
The intermittency of the wind turbine power remains an important issue for the massive development of this renewable energy. The energy peaks injected in the electric grid produce difficulties in the energy distribution management. Hence, a correct forecast of the wind power in the short and middle term is needed due to the high unpredictability of the intermittency phenomenon. We consider a statistical approach through the analysis and characterization of stochastic fluctuations. The theoretical framework is the multifractal modelisation of wind velocity fluctuations. Here, we consider three wind turbine data where two possess a direct drive technology. Those turbines are producing energy in real exploitation conditions and allow to test our forecast models of power production at a different time horizons. Two forecast models were developed based on two physical principles observed in the wind and the power time series: the scaling properties on the one hand and the intermittency in the wind power increments on the other. The first tool is related to the intermittency through a multifractal lognormal fit of the power fluctuations. The second tool is based on an analogy of the power scaling properties with a fractional brownian motion. Indeed, an inner long-term memory is found in both time series. Both models show encouraging results since a correct tendency of the signal is respected over different time scales. Those tools are first steps to a search of efficient forecasting approaches for grid adaptation facing the wind energy fluctuations.
Perini, Francesca; Caramazza, Alfonso; Peelen, Marius V.
2014-01-01
Functional neuroimaging studies have implicated the left lateral occipitotemporal cortex (LOTC) in both tool and hand perception but the functional role of this region is not fully known. Here, by using a task manipulation, we tested whether tool-/hand-selective LOTC contributes to the discrimination of tool-associated hand actions. Participants viewed briefly presented pictures of kitchen and garage tools while they performed one of two tasks: in the action task, they judged whether the tool is associated with a hand rotation action (e.g., screwdriver) or a hand squeeze action (e.g., garlic press), while in the location task they judged whether the tool is typically found in the kitchen (e.g., garlic press) or in the garage (e.g., screwdriver). Both tasks were performed on the same stimulus set and were matched for difficulty. Contrasting fMRI responses between these tasks showed stronger activity during the action task than the location task in both tool- and hand-selective LOTC regions, which closely overlapped. No differences were found in nearby object- and motion-selective control regions. Importantly, these findings were confirmed by a TMS study, which showed that effective TMS over the tool-/hand-selective LOTC region significantly slowed responses for tool action discriminations relative to tool location discriminations, with no such difference during sham TMS. We conclude that left LOTC contributes to the discrimination of tool-associated hand actions. PMID:25140142
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-06
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-803] Heavy Forged Hand Tools... review on heavy forged hand tools, finished or unfinished, with or without handles from the People's..., 2012) (Tianjin v. United States). \\2\\ See Heavy Forged Hand Tools, Finished or Unfinished, With or...
Trombert-Paviot, B; Rodrigues, J M; Rogers, J E; Baud, R; van der Haring, E; Rassinoux, A M; Abrial, V; Clavel, L; Idir, H
2000-09-01
Generalised architecture for languages, encyclopedia and nomenclatures in medicine (GALEN) has developed a new generation of terminology tools based on a language independent model describing the semantics and allowing computer processing and multiple reuses as well as natural language understanding systems applications to facilitate the sharing and maintaining of consistent medical knowledge. During the European Union 4 Th. framework program project GALEN-IN-USE and later on within two contracts with the national health authorities we applied the modelling and the tools to the development of a new multipurpose coding system for surgical procedures named CCAM in a minority language country, France. On one hand, we contributed to a language independent knowledge repository and multilingual semantic dictionaries for multicultural Europe. On the other hand, we support the traditional process for creating a new coding system in medicine which is very much labour consuming by artificial intelligence tools using a medically oriented recursive ontology and natural language processing. We used an integrated software named CLAW (for classification workbench) to process French professional medical language rubrics produced by the national colleges of surgeons domain experts into intermediate dissections and to the Grail reference ontology model representation. From this language independent concept model representation, on one hand, we generate with the LNAT natural language generator controlled French natural language to support the finalization of the linguistic labels (first generation) in relation with the meanings of the conceptual system structure. On the other hand, the Claw classification manager proves to be very powerful to retrieve the initial domain experts rubrics list with different categories of concepts (second generation) within a semantic structured representation (third generation) bridge to the electronic patient record detailed terminology.
Lott, Gus K; Johnson, Bruce R; Bonow, Robert H; Land, Bruce R; Hoy, Ronald R
2009-01-01
We report on the real-time creation of an application for hands-on neurophysiology in an advanced undergraduate teaching laboratory. Enabled by the rapid software development tools included in the Matlab technical computing environment (The Mathworks, Natick, MA), a team, consisting of a neurophysiology educator and a biophysicist trained as an electrical engineer, interfaced to a course of approximately 15 students from engineering and biology backgrounds. The result is the powerful freeware data acquisition and analysis environment, "g-PRIME." The software was developed from week to week in response to curriculum demands, and student feedback. The program evolved from a simple software oscilloscope, enabling RC circuit analysis, to a suite of tools supporting analysis of neuronal excitability and synaptic transmission analysis in invertebrate model systems. The program has subsequently expanded in application to university courses, research, and high school projects in the US and abroad as free courseware.
Laboratory and Workplace Assessments of Rivet Bucking Bar Vibration Emissions
McDowell, Thomas W.; Warren, Christopher; Xu, Xueyan S.; Welcome, Daniel E.; Dong, Ren G.
2016-01-01
Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool weight, comfort, worker acceptance, and initial cost can be used to make informed bucking bar selections. PMID:25381185
Laboratory and workplace assessments of rivet bucking bar vibration emissions.
McDowell, Thomas W; Warren, Christopher; Xu, Xueyan S; Welcome, Daniel E; Dong, Ren G
2015-04-01
Sheet metal workers operating rivet bucking bars are at risk of developing hand and wrist musculoskeletal disorders associated with exposures to hand-transmitted vibrations and forceful exertions required to operate these hand tools. New bucking bar technologies have been introduced in efforts to reduce workplace vibration exposures to these workers. However, the efficacy of these new bucking bar designs has not been well documented. While there are standardized laboratory-based methodologies for assessing the vibration emissions of many types of powered hand tools, no such standard exists for rivet bucking bars. Therefore, this study included the development of a laboratory-based method for assessing bucking bar vibrations which utilizes a simulated riveting task. With this method, this study evaluated three traditional steel bucking bars, three similarly shaped tungsten alloy bars, and three bars featuring spring-dampeners. For comparison the bucking bar vibrations were also assessed during three typical riveting tasks at a large aircraft maintenance facility. The bucking bars were rank-ordered in terms of unweighted and frequency-weighted acceleration measured at the hand-tool interface. The results suggest that the developed laboratory method is a reasonable technique for ranking bucking bar vibration emissions; the lab-based riveting simulations produced similar rankings to the workplace rankings. However, the laboratory-based acceleration averages were considerably lower than the workplace measurements. These observations suggest that the laboratory test results are acceptable for comparing and screening bucking bars, but the laboratory measurements should not be directly used for assessing the risk of workplace bucking bar vibration exposures. The newer bucking bar technologies exhibited significantly reduced vibrations compared to the traditional steel bars. The results of this study, together with other information such as rivet quality, productivity, tool weight, comfort, worker acceptance, and initial cost can be used to make informed bucking bar selections. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.
Leclère, Franck Marie; Schoofs, Michel; Vogt, Peter; Casoli, Vincent; Mordon, Serge
2015-05-01
Based on previous observations, the 1950-nm diode laser seems to be an ideal wavelength for laser microvascular anastomoses. The data presented here, part of a larger ongoing study, assess its use in emergency hand surgery. Between 2011 and 2014, 11 patients were operated on for hand trauma with laser-assisted microanastomoses (LAMA) and prospectively analysed. LAMA was performed with a 1950-nm diode laser after placement of equidistant stitches. For vessel size <1.5 mm, the following laser parameters were used: spot size 400 μm, five spots for each wall, power 125 mW, and arterial/venous fluence 100/90 J/cm(2) (spot duration 1/0.9 s). Mean operating time for arterial and venous microanastomoses was 7.3 ± 1.4 and 8.7 ± 1.0 min, respectively. Three anastomoses required a secondary laser application. Arterial and venous patency rates were 100 % at the time of surgery. The success rate for the 11 procedures assessed clinically and with the Doppler was 100 %. The technique is compared to the current literature. The 1950-nm LAMA is a reliable tool with excellent results in emergency hand surgery. The system is very compact and transportable for utilization in the emergency operating room.
A hand-powered, portable, low-cost centrifuge for diagnosing anemia in low-resource settings.
Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z Maria; Richards-Kortum, Rebecca
2011-08-01
This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate.
A Hand-Powered, Portable, Low-Cost Centrifuge for Diagnosing Anemia in Low-Resource Settings
Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z. Maria; Richards-Kortum, Rebecca
2011-01-01
This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate. PMID:21813855
MARZKE, MARY W.; MARZKE, R. F.
2000-01-01
The discovery of fossil hand bones from an early human ancestor at Olduvai Gorge in 1960, at the same level as primitive stone tools, generated a debate about the role of tools in the evolution of the human hand that has raged to the present day. Could the Olduvai hand have made the tools? Did the human hand evolve as an adaptation to tool making and tool use? The debate has been fueled by anatomical studies comparing living and fossil human and nonhuman primate hands, and by experimental observations. These have assessed the relative abilities of apes and humans to manufacture the Oldowan tools, but consensus has been hampered by disagreements about how to translate experimental data from living species into quantitative models for predicting the performance of fossil hands. Such models are now beginning to take shape as new techniques are applied to the capture, management and analysis of data on kinetic and kinematic variables ranging from hand joint structure, muscle mechanics, and the distribution and density of bone to joint movements and muscle recruitment during manipulative behaviour. The systematic comparative studies are highlighting a functional complex of features in the human hand facilitating a distinctive repertoire of grips that are apparently more effective for stone tool making than grips characterising various nonhuman primate species. The new techniques are identifying skeletal variables whose form may provide clues to the potential of fossil hominid hands for one-handed firm precision grips and fine precision manoeuvering movements, both of which are essential for habitual and effective tool making and tool use. PMID:10999274
Carpal tunnel syndrome: the role of occupational factors.
Palmer, Keith T
2011-02-01
Carpal tunnel syndrome (CTS) is a fairly common condition in working-aged people, sometimes caused by physical occupational activities, such as repeated and forceful movements of the hand and wrist or use of hand-held, powered, vibratory tools. Symptoms may be prevented or alleviated by primary control measures at work, and some cases of disease are compensable. Following a general description of the disorder, its epidemiology and some of the difficulties surrounding diagnosis, this review focusses on the role of occupational factors in causation of CTS and factors that can mitigate risk. Areas of uncertainty, debate and research interest are emphasised where relevant. Copyright © 2011 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Brinson, Sabrina A.
2009-01-01
Stories are important teaching tools. To ensure that young children are informed and experience more than a handful of African American women and girls' stories and authors, this article showcases notable and little-known accomplishments of exceptional women, real and imaginary. Brinson offers an annotated list of children's literature, fiction…
The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions.
McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G
2016-04-01
Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.
The Effect of a Mechanical Arm System on Portable Grinder Vibration Emissions
McDowell, Thomas W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; Dong, Ren G.
2016-01-01
Mechanical arm systems are commonly used to support powered hand tools to alleviate ergonomic stressors related to the development of workplace musculoskeletal disorders. However, the use of these systems can increase exposure times to other potentially harmful agents such as hand-transmitted vibration. To examine how these tool support systems affect tool vibration, the primary objectives of this study were to characterize the vibration emissions of typical portable pneumatic grinders used for surface grinding with and without a mechanical arm support system at a workplace and to estimate the potential risk of the increased vibration exposure time afforded by the use of these mechanical arm systems. This study also developed a laboratory-based simulated grinding task based on the ISO 28927-1 (2009) standard for assessing grinder vibrations; the simulated grinding vibrations were compared with those measured during actual workplace grinder operations. The results of this study demonstrate that use of the mechanical arm may provide a health benefit by reducing the forces required to lift and maneuver the tools and by decreasing hand-transmitted vibration exposure. However, the arm does not substantially change the basic characteristics of grinder vibration spectra. The mechanical arm reduced the average frequency-weighted acceleration by about 24% in the workplace and by about 7% in the laboratory. Because use of the mechanical arm system can increase daily time-on-task by 50% or more, the use of such systems may actually increase daily time-weighted hand-transmitted vibration exposures in some cases. The laboratory acceleration measurements were substantially lower than the workplace measurements, and the laboratory tool rankings based on acceleration were considerably different than those from the workplace. Thus, it is doubtful that ISO 28927-1 is useful for estimating workplace grinder vibration exposures or for predicting workplace grinder acceleration rank orders. PMID:26628522
OptoBase: A web platform for molecular optogenetics.
Kolar, Katja; Knobloch, Christian; Stork, Hendrik; Žnidarič, Matej; Weber, Wilfried
2018-06-18
OptoBase is an online platform for molecular optogenetics. At its core is a hand-annotated and ontology-supported database that aims to cover all existing optogenetic switches and publications, which is further complemented with a collection of convenient optogenetics-related web tools. OptoBase is meant for both expert optogeneticists, to easily keep track of the field, as well as for all researchers who find optogenetics inviting as a powerful tool to address their biological questions of interest. It is available at https://www.optobase.org. This work also presents OptoBase-based analysis of the trends in molecular optogenetics.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-457-A-D Third Review] Heavy Forged Hand... Heavy Forged Hand Tools From China. AGENCY: United States International Trade Commission. ACTION: Notice... the antidumping duty orders on heavy forged hand tools from China would be likely to lead to...
Computer implemented method, and apparatus for controlling a hand-held tool
NASA Technical Reports Server (NTRS)
Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)
1999-01-01
The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.
Forces associated with pneumatic power screwdriver operation: statics and dynamics.
Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G
2003-10-10
The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders.
Human-Computer Interaction and Information Management Research Needs
2003-10-01
Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be...hand-held personal digital assistants, networked sensors and actuators, and low-power computers on satellites. 5 most complex tools that humans have...calculations using data on external media such as tapes evolved into our multi-functional 21st century systems. More ideas came as networks of computing
Satellite services system overview
NASA Technical Reports Server (NTRS)
Rysavy, G.
1982-01-01
The benefits of a satellite services system and the basic needs of the Space Transportation System to have improved satellite service capability are identified. Specific required servicing equipment are discussed in terms of their technology development status and their operative functions. Concepts include maneuverable television systems, extravehicular maneuvering unit, orbiter exterior lighting, satellite holding and positioning aid, fluid transfer equipment, end effectors for the remote manipulator system, teleoperator maneuvering system, and hand and power tools.
Tool for Crimping Flexible Circuit Leads
NASA Technical Reports Server (NTRS)
Hulse, Aaron; Diftler, Myron A.
2009-01-01
A hand tool has been developed for crimping leads in flexible tails that are parts of some electronic circuits -- especially some sensor circuits. The tool is used to cut the tails to desired lengths and attach solder tabs to the leads. For tailoring small numbers of circuits for special applications, this hand tool is a less expensive alternative to a commercially available automated crimping tool. The crimping tool consists of an off-the-shelf hand crimping tool plus a specialized crimping insert designed specifically for the intended application.
NASA Astrophysics Data System (ADS)
Ren, Jie
2017-12-01
The process by which a kinesin motor couples its ATPase activity with concerted mechanical hand-over-hand steps is a foremost topic of molecular motor physics. Two major routes toward elucidating kinesin mechanisms are the motility performance characterization of velocity and run length, and single-molecular state detection experiments. However, these two sets of experimental approaches are largely uncoupled to date. Here, we introduce an integrative motility state analysis based on a theorized kinetic graph theory for kinesin, which, on one hand, is validated by a wealth of accumulated motility data, and, on the other hand, allows for rigorous quantification of state occurrences and chemomechanical cycling probabilities. An interesting linear scaling for kinesin motility performance across species is discussed as well. An integrative kinetic graph theory analysis provides a powerful tool to bridge motility and state characterization experiments, so as to forge a unified effort for the elucidation of the working mechanisms of molecular motors.
Garmer, Karin; Sperling, Lena; Forsberg, Anette
2002-01-01
A need for a hand-ergonomics training kit has been identified to increase critical thinking concerning choice of hand tools. This study deals with the design, use and evaluation of a hand-ergonomics training kit for use in ergonomics training programmes. The effects on awareness of hand ergonomics among training course participants have been evaluated by means of a questionnaire and interviews at a car production plant in Sweden. The evaluation was carried out about one and a half years after training with the hand-ergonomics training kit. The training kit consists of a guide to practical exercises, equipment for measuring hand size and strength, examples of hand tools for use in practical exercises, equipment for testing and evaluating the hand tools and checklists and judgement forms for qualitative evaluation. In addition, the kit contains relevant scientifically based reference reports on hand ergonomics. The evaluation showed that the practical exercises with the hand-ergonomic training kit had, to a remarkable extent, increased individuals' awareness of anthropometric differences and of the importance of ergonomically well-designed hand tools. After the practical exercises with the training kit, communication within the plant when choosing hand tools seems to be based on objective criteria to a higher degree, however, the results indicate that this communication could be further improved.
Hand preferences in captive orangutans (Pongo pygmaeus).
O'malley, Robert C; McGrew, W C
2006-07-01
The strength of the evidence for population-level handedness in the great apes is a topic of considerable debate, yet there have been few studies of handedness in orangutans. We conducted a study of manual lateralization in a captive group of eight orangutans (Pongo pygmaeus) ranking the degrees of manual preference according to a defined framework. We analyzed five behavioral patterns: eat (one- and two-handed), make/modify tool, oral tool-use, and manual tool-use. Although some individuals showed significant manual preferences for one or more tasks, at the group-level both one-handed and two-handed eating, oral tool-use, and make/modify tool were ranked at level 1 (unlateralized). Manual tool-use was ranked at level 2, with four subjects demonstrating significant hand preferences, but no group-level bias to the right or left. Four subjects also showed hand specialization to the right or left across several tasks. These results are consistent with most previous studies of manual preference in orangutans. The emergence of manual lateralization in orangutans may relate to more complex manipulative tasks. We hypothesize that more challenging manual tasks elicit stronger hand preferences.
Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.
Dong, R G; Rakheja, S; Schopper, A W; Han, B; Smutz, W P
2001-01-01
Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.
Povinelli, Daniel J; Reaux, James E; Frey, Scott H
2010-01-01
Considerable attention has been devoted to behaviors in which tools are used to perform actions in extrapersonal space by extending the reach. Evidence suggests that these behaviors result in an expansion of the body schema and peripersonal space. However, humans often use tools to perform tasks within peripersonal space that cannot be accomplished with the hands. In some of these instances (e.g., cooking), a tool is used as a substitute for the hand in order to pursue actions that would otherwise be hazardous. These behaviors suggest that even during the active use of tools, we maintain non-isomorphic representations that distinguish between our hands and handheld tools. Understanding whether such representations are a human specialization is of potentially great relevance to understand the evolutionary history of technological behaviors including the controlled use of fire. We tested six captive adult chimpanzees to determine whether they would elect to use a tool, rather than their hands, when acting in potentially hazardous vs. nonhazardous circumstances located within reach. Their behavior suggests that, like humans, chimpanzees represent the distinction between the hand vs. tool even during active use. We discuss the implications of this evidence for our understanding of tool use and its evolution.
Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions.
McDowell, Thomas W; Dong, Ren G; Welcome, Daniel E; Xu, Xueyan S; Warren, Christopher
2013-01-01
Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand-arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary: This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction.
Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators
NASA Technical Reports Server (NTRS)
Simons, Rainee N (Inventor); Miranda, Felix Antonio (Inventor)
2007-01-01
A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Tools and Related Equipment § 1915.133 Hand...) Employers shall not issue or permit the use of unsafe hand tools. (b) Wrenches, including crescent, pipe...
Hankir, Ahmed; Holloway, David; Zaman, Rashid; Agius, Mark
2015-09-01
Film possesses an extraordinary power and offers an unrivalled medium for entertainment and escapism. There are many films that revolve around a mental illness theme and the medical specialty that most commonly features in motion picture is psychiatry. Over the last few decades films have become increasingly used as an educational tool in the teaching of psychiatry topics such as mental state examination to undergraduate students. Above and beyond its utility in pedagogy, film also has the power to heal and the term cinematherapy has been coined to reflect this. Indeed, there are case studies of people with first-hand experience of psychopathology who report that watching films with a mental illness theme has contributed to their recovery. We provide a first person narrative from an individual with schizophrenia in which he expounds on the concepts of cinematherpy and metaphorical imagery in films which theme on psychosis.
2016-09-01
10 Fig. 8 Lithium ion polymer battery .................................................................. 11 Fig. 9 PowerBoost 1000C (right) and...7]. http://www.adafruit.com/products/1552. 7. Lithium Ion Polymer Battery –3.7v 2500mAh. [accessed Jul 7]. https://www.adafruit.com/products/328. 8...port directly) RealTek RT5370 Wi-Fi USB adapter 1 Wire-wrapping wires . . . Wire-wrap hand tool . . . Soldering kit . . . alipo: lithium - ion
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Hand tools. 1915.133 Section 1915.133 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Tools and Related Equipment § 1915.133 Hand...
Andres, Michael; Pelgrims, Barbara; Olivier, Etienne
2013-09-01
Neuropsychological studies showed that manipulatory and semantic knowledge can be independently impaired in patients with upper-limb apraxia, leading to different tool use disorders. The present study aimed to dissociate the brain regions involved in judging the hand configuration or the context associated to tool use. We focussed on the left supramarginalis gyrus (SMG) and left middle temporal gyrus (MTG), whose activation, as evidenced by functional magnetic resonance imaging (fMRI) studies, suggests that they may play a critical role in tool use. The distinctive location of SMG in the dorsal visual stream led us to postulate that this parietal region could play a role in processing incoming information about tools to shape hand posture. In contrast, we hypothesized that MTG, because of its interconnections with several cortical areas involved in semantic memory, could contribute to retrieving semantic information necessary to create a contextual representation of tool use. To test these hypotheses, we used neuronavigated transcranial magnetic stimulation (TMS) to interfere transiently with the function of either left SMG or left MTG in healthy participants performing judgement tasks about either hand configuration or context of tool use. We found that SMG virtual lesions impaired hand configuration but not contextual judgements, whereas MTG lesions selectively interfered with judgements about the context of tool use while leaving hand configuration judgements unaffected. This double dissociation demonstrates that the ability to infer a context of use or a hand posture from tool perception relies on distinct processes, performed in the temporal and parietal regions. The present findings suggest that tool use disorders caused by SMG lesions will be characterized by difficulties in selecting the appropriate hand posture for tool use, whereas MTG lesions will yield difficulties in using tools in the appropriate context. Copyright © 2012. Published by Elsevier Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-22
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-803] Heavy Forged Hand Tools (i.e... Administration, Department of Commerce. SUMMARY: As a result of the determinations by the Department of Commerce... on heavy forged hand tools (i.e., [[Page 52314
Subjective scaling of hand-arm vibration.
Maeda, Setsuo; Shibata, Nobuyuki
2008-04-01
The purpose of this research was to establish a scale for comfort with regard to hand-arm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from 1 to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at 1 Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.
Xin-Gang, Zhao; Yu-Zhuo, Zhang; Ling-Zhi, Ren; Yi, Zuo; Zhi-Gong, Wu
2017-10-01
Among the regulatory policies, feed-in tariffs (FIT) and renewable portfolio standards (RPS) are the most popular to promote the development of renewable energy power industry. They can significantly contribute to the expansion of domestic industrial activities in terms of sustainable energy. This paper uses system dynamics (SD) to establish models of long-term development of China's waste incineration power industry under FIT and RPS schemes, and provides a case study by using scenario analysis method. The model, on the one hand, not only clearly shows the complex logical relationship between the factors but also assesses policy effects of the two policy tools in the development of the industry. On the other hand, it provides a reference for scholars to study similar problems in different countries, thereby facilitating an understanding of waste incineration power's long-term sustainable development pattern under FIT and RPS schemes, and helping to provide references for policy-making institutions. The results show that in the perfect competitive market, the implementation of RPS can promote long-term and rapid development of China's waste incineration power industry given the constraints and actions of the mechanisms of RPS quota proportion, the TGC valid period, and fines, compared with FIT. At the end of the paper, policy implications are offered as references for the government. Copyright © 2017 Elsevier Ltd. All rights reserved.
Decoding the neural mechanisms of human tool use
Gallivan, Jason P; McLean, D Adam; Valyear, Kenneth F; Culham, Jody C
2013-01-01
Sophisticated tool use is a defining characteristic of the primate species but how is it supported by the brain, particularly the human brain? Here we show, using functional MRI and pattern classification methods, that tool use is subserved by multiple distributed action-centred neural representations that are both shared with and distinct from those of the hand. In areas of frontoparietal cortex we found a common representation for planned hand- and tool-related actions. In contrast, in parietal and occipitotemporal regions implicated in hand actions and body perception we found that coding remained selectively linked to upcoming actions of the hand whereas in parietal and occipitotemporal regions implicated in tool-related processing the coding remained selectively linked to upcoming actions of the tool. The highly specialized and hierarchical nature of this coding suggests that hand- and tool-related actions are represented separately at earlier levels of sensorimotor processing before becoming integrated in frontoparietal cortex. DOI: http://dx.doi.org/10.7554/eLife.00425.001 PMID:23741616
A two scale modeling and computational framework for vibration-induced Raynaud syndrome.
Hua, Yue; Lemerle, Pierre; Ganghoffer, Jean-François
2017-07-01
Hand-Arm Vibration syndrome (HAVS), usually caused by long-term use of hand-held power tools, can in certain manifestations alter the peripheral blood circulation in the hand-arm region. HAVS typically occurs after exposure to cold, causing an abnormally strong vasoconstriction of blood vessels. A pathoanatomical mechanism suggests that a reduction of the lumen of the blood vessels in VWF (Vibration White Finger) subjects, due to either hypertrophy or thickening of the vessel wall, may be at the origin of the disease. However, the direct and indirect effects of the load of the hand-held tools on the structure of blood vessels remain controversial:.one hypothesis is the mechanical action of vibration on the local acral dysregulation and/or on the vessel histomorphological modifications. Another hypothesis is the participation of the sympathetic nervous system to this dysregulation. In this paper, we assume the modifications as mechanobiological growth and the load-effect relationship may be interpreted as directly or indirectly induced. This work is the first attempt to model the effect of vibration through soft tissues onto the distal capillaries, addressing the double paradigm of multi space-time scales, i.e. low period vibration versus high time constant of the growth phenomenon as well as vibrations propagating in the macroscopic tissue including the microscopic capillary structures subjected to a pathological microstructural evolution. The objective is to lay down the theoretical basis of growth modeling for the small distal artery, with the ability to predict the geometrical and structural changes of the arterial walls caused by vibration exposure. We adopt the key idea of splitting the problem into one global vibration problem at the macroscopic scale and one local growth problem at the micro level. The macroscopic hyperelastic viscous dynamic model of the fingertip cross-section is validated by fitting experimental data. It is then used in steady-state vibration conditions to predict the mechanical fields in the close vicinity of capillaries. The space scale transfer from macroscopic to microscopic levels is ensured by considering a representative volume element (RVE) embedding a single capillary in its center. The vibrations emitted by the hand held power tool are next linked to the capillary growth through the adopted biomechanical growth model at the capillary level. The obtained results show that vibrations induce an increase of the thickness of the capillary's wall, thereby confirming the scenario of vibrations induced reduction of the lumen of blood vessels. Copyright © 2017 Elsevier Ltd. All rights reserved.
Chung, Beom Sun; Chung, Min Suk; Shin, Byeong Seok; Kwon, Koojoo
2018-02-19
The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. © 2018 The Korean Academy of Medical Sciences.
2018-01-01
Background The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. Methods On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. Results All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. Conclusion These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. PMID:29441756
Basic Hand Tools for Bricklaying and Cement Masonry [and] Basic Hand Tools of the Carpenter.
ERIC Educational Resources Information Center
Texas A and M Univ., College Station. Vocational Instructional Services.
Intended for student use, this unit discusses and illustrates the tools used in brick and masonry and carpentry. Contents of the brick and masonry section include informative materials on bricklaying tools (brick trowels, joint tools, levels, squares, line and accessories, rules, hammers and chisels, tool kits) and cement masonry tools (tampers,…
Discover Space Weather and Sun's Superpowers: Using CCMC's innovative tools and applications
NASA Astrophysics Data System (ADS)
Mendoza, A. M. M.; Maddox, M. M.; Kuznetsova, M. M.; Chulaki, A.; Rastaetter, L.; Mullinix, R.; Weigand, C.; Boblitt, J.; Taktakishvili, A.; MacNeice, P. J.; Pulkkinen, A. A.; Pembroke, A. D.; Mays, M. L.; Zheng, Y.; Shim, J. S.
2015-12-01
Community Coordinated Modeling Center (CCMC) has developed a comprehensive set of tools and applications that are directly applicable to space weather and space science education. These tools, some of which were developed by our student interns, are capable of serving a wide range of student audiences, from middle school to postgraduate research. They include a web-based point of access to sophisticated space physics models and visualizations, and a powerful space weather information dissemination system, available on the web and as a mobile app. In this demonstration, we will use CCMC's innovative tools to engage the audience in real-time space weather analysis and forecasting and will share some of our interns' hands-on experiences while being trained as junior space weather forecasters. The main portals to CCMC's educational material are ccmc.gsfc.nasa.gov and iswa.gsfc.nasa.gov
Hand-independent representation of tool-use pantomimes in the left anterior intraparietal cortex.
Ogawa, Kenji; Imai, Fumihito
2016-12-01
Previous neuropsychological studies of ideomotor apraxia (IMA) indicated impairments in pantomime actions for tool use for both right and left hands following lesions of parieto-premotor cortices in the left hemisphere. Using functional magnetic resonance imaging (fMRI) with multi-voxel pattern analysis (MVPA), we tested the hypothesis that the left parieto-premotor cortices are involved in the storage or retrieval of hand-independent representation of tool-use actions. In the fMRI scanner, one of three kinds of tools was displayed in pictures or letters, and the participants made pantomimes of the use of these tools using the right hand for the picture stimuli or with the left hand for the letters. We then used MVPA to classify which kind of tool the subjects were pantomiming. Whole-brain searchlight analysis revealed successful decoding using the activities largely in the contralateral primary sensorimotor region, ipsilateral cerebellum, and bilateral early visual area, which may reflect differences in low-level sensorimotor components for three types of pantomimes. Furthermore, a successful cross-classification between the right and left hands was possible using the activities of the left inferior parietal lobule (IPL) near the junction of the anterior intraparietal sulcus. Our finding indicates that the left anterior intraparietal cortex plays an important role in the production of tool-use pantomimes in a hand-independent manner, and independent of stimuli modality.
Tool use and the distalization of the end-effector
Bonaiuto, James B.; Jacobs, Stéphane; Frey, Scott H.
2009-01-01
We review recent neurophysiological data from macaques and humans suggesting that the use of tools extends the internal representation of the actor’s hand, and relate it to our modeling of the visual control of grasping. We introduce the idea that, in addition to extending the body schema to incorporate the tool, tool use involves distalization of the end-effector from hand to tool. Different tools extend the body schema in different ways, with a displaced visual target and a novel, task-specific processing of haptic feedback to the hand. This distalization is critical in order to exploit the unique functional capacities engendered by complex tools. PMID:19347356
The recalibration of tactile perception during tool use is body-part specific
Cawley-Bennett, Andrew; Longo, Matthew R.; Saygin, Ayse P.
2018-01-01
Two decades of research have demonstrated that using a tool modulates spatial representations of the body. Whether this embodiment is specific to representations of the tool-using limb or extends to representations of other body parts has received little attention. Several studies of other perceptual phenomena have found that modulations to the primary somatosensory representation of the hand transfers to the face, due in part to their close proximity in primary somatosensory cortex. In the present study, we investigated whether tool-induced recalibration of tactile perception on the hand transfers to the cheek. Participants verbally estimated the distance between two tactile points applied to either their hand or face, before and after using a hand-shaped tool. Tool use recalibrated tactile distance perception on the hand—in line with previous findings—but left perception on the cheek unchanged. This finding provides support for the idea that embodiment is body-part specific. Furthermore, it suggests that tool-induced perceptual recalibration occurs at a level of somatosensory processing, where representations of the hand and face have become functionally disentangled. PMID:28702834
NASA Astrophysics Data System (ADS)
Haddag, B.; Kagnaya, T.; Nouari, M.; Cutard, T.
2013-01-01
Modelling machining operations allows estimating cutting parameters which are difficult to obtain experimentally and in particular, include quantities characterizing the tool-workpiece interface. Temperature is one of these quantities which has an impact on the tool wear, thus its estimation is important. This study deals with a new modelling strategy, based on two steps of calculation, for analysis of the heat transfer into the cutting tool. Unlike the classical methods, considering only the cutting tool with application of an approximate heat flux at the cutting face, estimated from experimental data (e.g. measured cutting force, cutting power), the proposed approach consists of two successive 3D Finite Element calculations and fully independent on the experimental measurements; only the definition of the behaviour of the tool-workpiece couple is necessary. The first one is a 3D thermomechanical modelling of the chip formation process, which allows estimating cutting forces, chip morphology and its flow direction. The second calculation is a 3D thermal modelling of the heat diffusion into the cutting tool, by using an adequate thermal loading (applied uniform or non-uniform heat flux). This loading is estimated using some quantities obtained from the first step calculation, such as contact pressure, sliding velocity distributions and contact area. Comparisons in one hand between experimental data and the first calculation and at the other hand between measured temperatures with embedded thermocouples and the second calculation show a good agreement in terms of cutting forces, chip morphology and cutting temperature.
Ostolaza, M; Abudarham, J; Dilascio, S; Drault-Boedo, E; Gallo, S; Garcete, A; Kramer, M; Maiaru, M; Mendelevich, A; Modica, M; Peralta, F; Sanchez-Correa, C
2017-04-01
In clinical practice it is important to be able to assess the function of the upper limb of the patient who has suffered a stroke. There is currently no systemic review that could identify assessment tools for the 'fine use of the hand' and 'use of both hand and arm'. Primary, to identify observational tools which can assess the fine use of the hand and the use of both hand and arm in patients with stroke sequels. Secondary, to analyze the bias risk in the included articles, describing and categorizing the clinical utility, validity and reliability. A search was carried in Medline, LILACS, SciELO and Open Grey, which included articles published until October 2015. Studies that validate assessing tools of the upper limb in subjects with a stroke sequel which evaluate the fine use of the hand and the use of both hand and arm were included. Eleven tools in evaluate observational haven been selected, which assess the fine use of the hand and the use of hand and arm. In every case both validity and reliability have been reported, but clinical utility has been less considered for assessment. The studies that researched these tools showed a high risk of bias in their development. ARAT-19 showed a lower bias risk, but when it has to do with applicability and the reference trial is taken into account, the level of concern is high.
Tool making, hand morphology and fossil hominins.
Marzke, Mary W
2013-11-19
Was stone tool making a factor in the evolution of human hand morphology? Is it possible to find evidence in fossil hominin hands for this capability? These questions are being addressed with increasingly sophisticated studies that are testing two hypotheses; (i) that humans have unique patterns of grip and hand movement capabilities compatible with effective stone tool making and use of the tools and, if this is the case, (ii) that there exist unique patterns of morphology in human hands that are consistent with these capabilities. Comparative analyses of human stone tool behaviours and chimpanzee feeding behaviours have revealed a distinctive set of forceful pinch grips by humans that are effective in the control of stones by one hand during manufacture and use of the tools. Comparative dissections, kinematic analyses and biomechanical studies indicate that humans do have a unique pattern of muscle architecture and joint surface form and functions consistent with the derived capabilities. A major remaining challenge is to identify skeletal features that reflect the full morphological pattern, and therefore may serve as clues to fossil hominin manipulative capabilities. Hominin fossils are evaluated for evidence of patterns of derived human grip and stress-accommodation features.
Tool making, hand morphology and fossil hominins
Marzke, Mary W.
2013-01-01
Was stone tool making a factor in the evolution of human hand morphology? Is it possible to find evidence in fossil hominin hands for this capability? These questions are being addressed with increasingly sophisticated studies that are testing two hypotheses; (i) that humans have unique patterns of grip and hand movement capabilities compatible with effective stone tool making and use of the tools and, if this is the case, (ii) that there exist unique patterns of morphology in human hands that are consistent with these capabilities. Comparative analyses of human stone tool behaviours and chimpanzee feeding behaviours have revealed a distinctive set of forceful pinch grips by humans that are effective in the control of stones by one hand during manufacture and use of the tools. Comparative dissections, kinematic analyses and biomechanical studies indicate that humans do have a unique pattern of muscle architecture and joint surface form and functions consistent with the derived capabilities. A major remaining challenge is to identify skeletal features that reflect the full morphological pattern, and therefore may serve as clues to fossil hominin manipulative capabilities. Hominin fossils are evaluated for evidence of patterns of derived human grip and stress-accommodation features. PMID:24101624
Skylight book. Capturing the Sun and the Moon: a guide to creating natural light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burns, A.
1976-01-01
The following topics are covered: planning; essential tools: hand and power; safety hints; curb installation; plexiglas or plate glass skylight; the plexiglas box skylight; tips on working with plexiglas; checking for leaks; framing the shaftway; electric work; shaftwall insulation; covering the shaftway with drywall; other kinds of wall coverings; internal storm windows; plants under your skylight; skylight manufacturers; and places to buy things. There are 38 pages of pictures of the use of skylights. (MHR)
NASA Technical Reports Server (NTRS)
Easton, John W.; Struk, Peter M.
2012-01-01
The Component Repair Experiment-1 (CRE-1) examines the capability for astronauts to perform electronics repair tasks in space. The goal is to determine the current capabilities and limits for the crew, and to make recommendations to improve and expand the range of work that astronauts may perform. CRE-1 provided two-layer, functional circuit boards and replacement components, a small tool kit, written and video training materials, and 1 hr of hands on training for the crew slated to perform the experiment approximately 7 months prior to the mission. Astronauts Michael Fincke and Sandra Magnus performed the work aboard the International Space Station (ISS) in February and March 2009. The astronauts were able to remove and replace components successfully, demonstrating the feasibility of performing component-level electronics repairs within a spacecraft. Several unsuccessful tasks demonstrated areas in need of improvement. These include improved and longer training prior to a mission, an improved soldering iron with a higher operating temperature and steady power source, video training and practice boards for refresher work or practice before a repair, and improved and varied hand tools and containment system.
Map showing relative ease of excavation in the Salina quadrangle, Utah
Williams, Paul L.
1972-01-01
This map shows the relative ease (or difficulty) with which rocks and surficial deposits can be excavated. Because of rapidly changing technology of excavation and considerable local variability of many rock units, it is not practical to specifically categorize rock units according to type of equipment needed for their excavations. However, it may be stated in general that rock units classed as very easy and easy can in most places be excavated by hand tools and by light machinery such as backhoes and small bulldozers; units included in easy to difficult require blasting and (or) heavy machinery such as rippers and large bulldozers for resistant rocks, and hand tools or light power equipment for soft rocks; and units classes as difficult and very difficult probably require blasting and heavy machinery.The excavation units shown here are based on map units of the geologic map of the Salina quadrangle. Where bedrock is mantled with thin unmapped surficial deposits, ease of excavation shown is that of the bedrock, not that of the thin surficial mantle; where surficial deposits are mapped, ease of excavation shown is that of surficial deposits.
Power flow as a complement to statistical energy analysis and finite element analysis
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1987-01-01
Present methods of analysis of the structural response and the structure-borne transmission of vibrational energy use either finite element (FE) techniques or statistical energy analysis (SEA) methods. The FE methods are a very useful tool at low frequencies where the number of resonances involved in the analysis is rather small. On the other hand SEA methods can predict with acceptable accuracy the response and energy transmission between coupled structures at relatively high frequencies where the structural modal density is high and a statistical approach is the appropriate solution. In the mid-frequency range, a relatively large number of resonances exist which make finite element method too costly. On the other hand SEA methods can only predict an average level form. In this mid-frequency range a possible alternative is to use power flow techniques, where the input and flow of vibrational energy to excited and coupled structural components can be expressed in terms of input and transfer mobilities. This power flow technique can be extended from low to high frequencies and this can be integrated with established FE models at low frequencies and SEA models at high frequencies to form a verification of the method. This method of structural analysis using power flo and mobility methods, and its integration with SEA and FE analysis is applied to the case of two thin beams joined together at right angles.
Task-specific motor performance and musculoskeletal response in self-classified right handers.
Kumar, Sameer; Mandal, Manas K
2003-11-01
We examined the difference between the left and right hand motor performance (in terms of erg produced) of self-classified right handers (15 men, 15 women) for power (task involving muscle force) and skilled (task involving precision and eye hand coordination) tasks. Musculoskeletal response during task performance was measured by electromyogram to test the hypothesis that performance with the nondominant hand would trigger more generalized muscle tension. The difference between the left and right hand performance of men was nonsignificant for power task; for women, right hand performance was significantly superior than left for such task. Men excelled in power and women excelled in skilled tasks relative to their counterparts. Generalized muscle tension was significantly more during the left than the right hand performance for power but not for skilled tasks.
The dark side of photovoltaic — 3D simulation of glare assessing risk and discomfort
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rose, Thomas; Wollert, Alexander
2015-04-15
Photovoltaic (PV) systems form an important force in the implementation of renewable energies, but as we all know, the force has always its dark side. Besides efficiency considerations and discussions about architectures of power distribution networks, the increasing numbers of installations of PV systems for implementing renewable energies have secondary effects. PV systems can generate glare due to optical reflections and hence might be a serious concern. On the one hand, glare could affect safety, e.g. regarding traffic. On the other hand, glare is a constant source of discomfort in vicinities of PV systems. Hence, assessment of glare is decisivemore » for the success of renewable energies near municipalities and traffic zones for the success of solar power. Several courts decided on the change of PV systems and even on their de-installation because of glare effects. Thus, location-based assessments are required to limit potential reflections and to avoid risks for public infrastructure or discomfort of residents. The question arises on how to calculate reflections accurately according to the environment's topography. Our approach is founded in a 3D-based simulation methodology to calculate and visualize reflections based on the geometry of the environment of PV systems. This computational model is implemented by an interactive tool for simulation and visualization. Hence, project planners receive flexible assistance for adjusting the parameters of solar panels amid the planning process and in particular before the installation of a PV system. - Highlights: • Solar panels cause glare that impacts neighborhoods and traffic infrastructures. • Glare might cause disability and discomfort. • 3D environment for the calculation of glare • Interactive tool to simulate and visualize reflections • Impact assessment of solar power plant farms.« less
A Prosthetic Hand Body Area Controller Based on Efficient Pattern Recognition Control Strategies.
Benatti, Simone; Milosevic, Bojan; Farella, Elisabetta; Gruppioni, Emanuele; Benini, Luca
2017-04-15
Poliarticulated prosthetic hands represent a powerful tool to restore functionality and improve quality of life for upper limb amputees. Such devices offer, on the same wearable node, sensing and actuation capabilities, which are not equally supported by natural interaction and control strategies. The control in state-of-the-art solutions is still performed mainly through complex encoding of gestures in bursts of contractions of the residual forearm muscles, resulting in a non-intuitive Human-Machine Interface (HMI). Recent research efforts explore the use of myoelectric gesture recognition for innovative interaction solutions, however there persists a considerable gap between research evaluation and implementation into successful complete systems. In this paper, we present the design of a wearable prosthetic hand controller, based on intuitive gesture recognition and a custom control strategy. The wearable node directly actuates a poliarticulated hand and wirelessly interacts with a personal gateway (i.e., a smartphone) for the training and personalization of the recognition algorithm. Through the whole system development, we address the challenge of integrating an efficient embedded gesture classifier with a control strategy tailored for an intuitive interaction between the user and the prosthesis. We demonstrate that this combined approach outperforms systems based on mere pattern recognition, since they target the accuracy of a classification algorithm rather than the control of a gesture. The system was fully implemented, tested on healthy and amputee subjects and compared against benchmark repositories. The proposed approach achieves an error rate of 1.6% in the end-to-end real time control of commonly used hand gestures, while complying with the power and performance budget of a low-cost microcontroller.
A Prosthetic Hand Body Area Controller Based on Efficient Pattern Recognition Control Strategies
Benatti, Simone; Milosevic, Bojan; Farella, Elisabetta; Gruppioni, Emanuele; Benini, Luca
2017-01-01
Poliarticulated prosthetic hands represent a powerful tool to restore functionality and improve quality of life for upper limb amputees. Such devices offer, on the same wearable node, sensing and actuation capabilities, which are not equally supported by natural interaction and control strategies. The control in state-of-the-art solutions is still performed mainly through complex encoding of gestures in bursts of contractions of the residual forearm muscles, resulting in a non-intuitive Human-Machine Interface (HMI). Recent research efforts explore the use of myoelectric gesture recognition for innovative interaction solutions, however there persists a considerable gap between research evaluation and implementation into successful complete systems. In this paper, we present the design of a wearable prosthetic hand controller, based on intuitive gesture recognition and a custom control strategy. The wearable node directly actuates a poliarticulated hand and wirelessly interacts with a personal gateway (i.e., a smartphone) for the training and personalization of the recognition algorithm. Through the whole system development, we address the challenge of integrating an efficient embedded gesture classifier with a control strategy tailored for an intuitive interaction between the user and the prosthesis. We demonstrate that this combined approach outperforms systems based on mere pattern recognition, since they target the accuracy of a classification algorithm rather than the control of a gesture. The system was fully implemented, tested on healthy and amputee subjects and compared against benchmark repositories. The proposed approach achieves an error rate of 1.6% in the end-to-end real time control of commonly used hand gestures, while complying with the power and performance budget of a low-cost microcontroller. PMID:28420135
NASA Technical Reports Server (NTRS)
Chandler, Faith T. (Inventor); Arnett, Michael C. (Inventor); Garton, Harry L. (Inventor); Valentino, William D. (Inventor)
2003-01-01
A fastener starter tool includes a number of spring retention fingers for retaining a small part, or combination of parts. The tool has an inner housing, which holds the spring retention fingers, a hand grip, and an outer housing configured to slide over the inner housing and the spring retention fingers toward and away from the hand grip, exposing and opening, or respectively, covering and closing, the spring retention fingers. By sliding the outer housing toward (away from) the hand grip, a part can be released from (retained by) the tool. The tool may include replaceable inserts, for retaining parts, such as screws, and configured to limit the torque applied to the part, to prevent cross threading. The inner housing has means to transfer torque from the hand grip to the insert. The tool may include replaceable bits, the inner housing having means for transferring torque to the replaceable bit.
An IoT-Enabled Stroke Rehabilitation System Based on Smart Wearable Armband and Machine Learning.
Yang, Geng; Deng, Jia; Pang, Gaoyang; Zhang, Hao; Li, Jiayi; Deng, Bin; Pang, Zhibo; Xu, Juan; Jiang, Mingzhe; Liljeberg, Pasi; Xie, Haibo; Yang, Huayong
2018-01-01
Surface electromyography signal plays an important role in hand function recovery training. In this paper, an IoT-enabled stroke rehabilitation system was introduced which was based on a smart wearable armband (SWA), machine learning (ML) algorithms, and a 3-D printed dexterous robot hand. User comfort is one of the key issues which should be addressed for wearable devices. The SWA was developed by integrating a low-power and tiny-sized IoT sensing device with textile electrodes, which can measure, pre-process, and wirelessly transmit bio-potential signals. By evenly distributing surface electrodes over user's forearm, drawbacks of classification accuracy poor performance can be mitigated. A new method was put forward to find the optimal feature set. ML algorithms were leveraged to analyze and discriminate features of different hand movements, and their performances were appraised by classification complexity estimating algorithms and principal components analysis. According to the verification results, all nine gestures can be successfully identified with an average accuracy up to 96.20%. In addition, a 3-D printed five-finger robot hand was implemented for hand rehabilitation training purpose. Correspondingly, user's hand movement intentions were extracted and converted into a series of commands which were used to drive motors assembled inside the dexterous robot hand. As a result, the dexterous robot hand can mimic the user's gesture in a real-time manner, which shows the proposed system can be used as a training tool to facilitate rehabilitation process for the patients after stroke.
Aldien, Yasser; Marcotte, Pierre; Rakheja, Subhash; Boileau, Paul-Emile
2005-07-01
The biodynamic responses of the hand-arm system under x(h)-axis vibration are investigated in terms of the driving point mechanical impedance (DPMI) and absorbed power in a laboratory study. For this purpose, seven healthy male subjects are exposed to two levels of random vibration in the 8-1,000 Hz frequency range, using three instrumented cylindrical handles of different diameters (30, 40 and 50 mm), and different combinations of grip (10, 30 and 50 N) and push (0, 25 and 50 N) forces. The experiments involve grasping the handle while adopting two different postures, involving elbow flexion of 90 degrees and 180 degrees, with wrist in the neutral position for both postures. The analyses of the results revealed peak DPMI magnitude and absorbed power responses near 25 Hz and 150 Hz, for majority of the test conditions considered. The frequency corresponding to the peak response increased with increasing hand forces. Unlike the absorbed power, the DPMI response was mostly observed to be insensitive to variations in the excitation magnitude. The handle diameter revealed obvious effects on the DPMI magnitude, specifically at frequencies above 250 Hz, which was not evident in the absorbed power due to relatively low velocity at higher frequencies. The influence of hand forces was also evident on the DPMI magnitude response particularly at frequencies. above 100 Hz, while the effect of hand-arm posture on the DPMI magnitude was nearly negligible. The magnitude of power absorbed within the hand and arm was observed to be strongly dependent upon the excitation level over the entire frequency range, while the influence of hand-arm posture on the total absorbed power was observed to be important. The effect of variations in the hand forces on the absorbed power was relatively small for the bent elbow posture, while an increase in either the grip or the push force coupled with the extended arm posture resulted in considerably higher energy absorption. The results suggested that the handle size, hand-arm posture and hand forces, produce coupled effect on the biodynamic response of the hand-arm system.
Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration
Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.
2016-01-01
BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for better effectiveness for protecting the fingers. PMID:27867313
Hopkins, William D; Meguerditchian, Adrien; Coulon, Olivier; Misiura, Maria; Pope, Sarah; Mareno, Mary Catherine; Schapiro, Steven J
2017-02-01
Among nonhuman primates, chimpanzees are well known for their sophistication and diversity of tool use in both captivity and the wild. The evolution of tool manufacture and use has been proposed as a driving mechanism for the development of increasing brain size, complex cognition and motor skills, as well as the population-level handedness observed in modern humans. Notwithstanding, our understanding of the neurological correlates of tool use in chimpanzees and other primates remains poorly understood. Here, we assessed the hand preference and performance skill of chimpanzees on a tool use task and correlated these data with measures of neuroanatomical asymmetries in the inferior frontal gyrus (IFG) and the pli-de-passage fronto-parietal moyen (PPFM). The IFG is the homolog to Broca's area in the chimpanzee brain and the PPFM is a buried gyrus that connects the pre- and post-central gyri and corresponds to the motor-hand area of the precentral gyrus. We found that chimpanzees that performed the task better with their right compared to left hand showed greater leftward asymmetries in the IFG and PPFM. This association between hand performance and PPFM asymmetry was particularly robust for right-handed individuals. Based on these findings, we propose that the evolution of tool use was associated with increased left hemisphere specialization for motor skill. We further suggest that lateralization in motor planning, rather than hand preference per se, was selected for with increasing tool manufacture and use in Hominid evolution. Copyright © 2016 Elsevier B.V. All rights reserved.
Hopkins, William D.; Meguerditchian, Adrien; Coulon, Olivier; Misiura, Maria; Pope, Sarah; Mareno, Mary Catherine; Schapiro, Steven J.
2017-01-01
Among nonhuman primates, chimpanzees are well known for their sophistication and diversity of tool use in both captivity and the wild. The evolution of tool manufacture and use has been proposed as a driving mechanism for the development of increasing brain size, complex cognition and motor skills, as well as the population-level handedness observed in modern humans. Notwithstanding, our understanding of the neurological correlates of tool use in chimpanzees and other primates remains poorly understood. Here, we assessed the hand preference and performance skill of chimpanzees on a tool use task and correlated these data with measures of neuroanatomical asymmetries in the inferior frontal gyrus (IFG) and the pli-de-passage fronto-parietal moyen (PPFM). The IFG is the homolog to Broca’s area in the chimpanzee brain and the PPFM is a buried gyrus that connects the pre- and post-central gyri and corresponds to the motor-hand area of the precentral gyrus. We found that chimpanzees that performed the task better with their right compared to left hand showed greater leftward asymmetries in the IFG and PPFM. This association between hand performance and PPFM asymmetry was particularly robust for right-handed individuals. Based on these findings, we propose that the evolution of tool use was associated with increased left hemisphere specialization for motor skill. We further suggest that lateralization in motor planning, rather than hand preference per se, was selected for with increasing tool manufacture and use in Hominid evolution. PMID:27816558
Humle, Tatyana; Matsuzawa, Tetsuro
2009-01-01
Population-level right handedness is a human universal, whose evolutionary origins are the source of considerable empirical and theoretical debate. Although our closest neighbor, the chimpanzee, shows some evidence for population-level handedness in captivity, there is little evidence from the wild. Tool-use measures of hand use in chimpanzees have yielded a great deal of variation in directionality and strength in hand preference, which still remains largely unexplored and unexplained. Data on five measures of hand use across four tool-use skills--ant-dipping, algae-scooping, pestle-pounding and nut-cracking--among the wild chimpanzees of Bossou, Guinea, West Africa, are presented here. This study aims to explore age- and sex-class effects, as well as the influence of task motor, cognitive and haptic demands, on the strength and directionality of hand preference within and across all five measures of hand use. Although there was no age- or sex-class effect on the directionality of hand preference, immature
NASA Technical Reports Server (NTRS)
2010-01-01
Topics covered include: Burnishing Techniques Strengthen Hip Implants; Signal Processing Methods Monitor Cranial Pressure; Ultraviolet-Blocking Lenses Protect, Enhance Vision; Hyperspectral Systems Increase Imaging Capabilities; Programs Model the Future of Air Traffic Management; Tail Rotor Airfoils Stabilize Helicopters, Reduce Noise; Personal Aircraft Point to the Future of Transportation; Ducted Fan Designs Lead to Potential New Vehicles; Winglets Save Billions of Dollars in Fuel Costs; Sensor Systems Collect Critical Aerodynamics Data; Coatings Extend Life of Engines and Infrastructure; Radiometers Optimize Local Weather Prediction; Energy-Efficient Systems Eliminate Icing Danger for UAVs; Rocket-Powered Parachutes Rescue Entire Planes; Technologies Advance UAVs for Science, Military; Inflatable Antennas Support Emergency Communication; Smart Sensors Assess Structural Health; Hand-Held Devices Detect Explosives and Chemical Agents; Terahertz Tools Advance Imaging for Security, Industry; LED Systems Target Plant Growth; Aerogels Insulate Against Extreme Temperatures; Image Sensors Enhance Camera Technologies; Lightweight Material Patches Allow for Quick Repairs; Nanomaterials Transform Hairstyling Tools; Do-It-Yourself Additives Recharge Auto Air Conditioning; Systems Analyze Water Quality in Real Time; Compact Radiometers Expand Climate Knowledge; Energy Servers Deliver Clean, Affordable Power; Solutions Remediate Contaminated Groundwater; Bacteria Provide Cleanup of Oil Spills, Wastewater; Reflective Coatings Protect People and Animals; Innovative Techniques Simplify Vibration Analysis; Modeling Tools Predict Flow in Fluid Dynamics; Verification Tools Secure Online Shopping, Banking; Toolsets Maintain Health of Complex Systems; Framework Resources Multiply Computing Power; Tools Automate Spacecraft Testing, Operation; GPS Software Packages Deliver Positioning Solutions; Solid-State Recorders Enhance Scientific Data Collection; Computer Models Simulate Fine Particle Dispersion; Composite Sandwich Technologies Lighten Components; Cameras Reveal Elements in the Short Wave Infrared; Deformable Mirrors Correct Optical Distortions; Stitching Techniques Advance Optics Manufacturing; Compact, Robust Chips Integrate Optical Functions; Fuel Cell Stations Automate Processes, Catalyst Testing; Onboard Systems Record Unique Videos of Space Missions; Space Research Results Purify Semiconductor Materials; and Toolkits Control Motion of Complex Robotics.
Simulation Tools and Techniques for Analyzing the Impacts of Photovoltaic System Integration
NASA Astrophysics Data System (ADS)
Hariri, Ali
Solar photovoltaic (PV) energy integration in distribution networks is one of the fastest growing sectors of distributed energy integration. The growth in solar PV integration is incentivized by various clean power policies, global interest in solar energy, and reduction in manufacturing and installation costs of solar energy systems. The increase in solar PV integration has raised a number of concerns regarding the potential impacts that might arise as a result of high PV penetration. Some impacts have already been recorded in networks with high PV penetration such as in China, Germany, and USA (Hawaii and California). Therefore, network planning is becoming more intricate as new technologies are integrated into the existing electric grid. The integrated new technologies pose certain compatibility concerns regarding the existing electric grid infrastructure. Therefore, PV integration impact studies are becoming more essential in order to have a better understanding of how to advance the solar PV integration efforts without introducing adverse impacts into the network. PV impact studies are important for understanding the nature of the new introduced phenomena. Understanding the nature of the potential impacts is a key factor for mitigating and accommodating for said impacts. Traditionally, electric power utilities relied on phasor-based power flow simulations for planning their electric networks. However, the conventional, commercially available, phasor-based simulation tools do not provide proper visibility across a wide spectrum of electric phenomena. Moreover, different types of simulation approaches are suitable for specific types of studies. For instance, power flow software cannot be used for studying time varying phenomena. At the same time, it is not practical to use electromagnetic transient (EMT) tools to perform power flow solutions. Therefore, some electric phenomena caused by the variability of PV generation are not visible using the conventional utility simulation software. On the other hand, EMT simulation tools provide high accuracy and visibility over a wide bandwidth of frequencies at the expense of larger processing and memory requirements, limited network size, and long simulation time. Therefore, there is a gap in simulation tools and techniques that can efficiently and effectively identify potential PV impact. New planning simulation tools are needed in order to accommodate for the simulation requirements of new integrated technologies in the electric grid. The dissertation at hand starts by identifying some of the potential impacts that are caused by high PV penetration. A phasor-based quasi-static time series (QSTS) analysis tool is developed in order to study the slow dynamics that are caused by the variations in the PV generation that lead to voltage fluctuations. Moreover, some EMT simulations are performed in order to study the impacts of PV systems on the electric network harmonic levels. These studies provide insights into the type and duration of certain impacts, as well as the conditions that may lead to adverse phenomena. In addition these studies present an idea about the type of simulation tools that are sufficient for each type of study. After identifying some of the potential impacts, certain planning tools and techniques are proposed. The potential PV impacts may cause certain utilities to refrain from integrating PV systems into their networks. However, each electric network has a certain limit beyond which the impacts become substantial and may adversely interfere with the system operation and the equipment along the feeder; this limit is referred to as the hosting limit (or hosting capacity). Therefore, it is important for utilities to identify the PV hosting limit on a specific electric network in order to safely and confidently integrate the maximum possible PV systems. In the following dissertation, two approaches have been proposed for identifying the hosing limit: 1. Analytical approach: this is a theoretical mathematical approach that demonstrated the understanding of the fundamentals of electric power system operation. It provides an easy way to estimate the maximum amount of PV power that can be injected at each node in the network. This approach has been tested and validated. 2. Stochastic simulation software approach: this approach provides a comprehensive simulation software that can be used in order to identify the PV hosting limit. The software performs a large number of stochastic simulation while varying the PV system size and location. The collected data is then analyzed for violations in the voltage levels, voltage fluctuations and reverse power flow. (Abstract shortened by ProQuest.).
Riolfi, A; Perbellini, L
2010-01-01
The use of nailfold capillaroscopy combined with skin thermometry in the study of microcirculation of the hands in workers exposed to hand-arm vibration is assessed. Fifty-eight subjects were studied; 40 asymptomatic forestry workers exposed to hand-arm vibration, 13 forestry workers exposed to hand-arm vibration with Raynaud-like symptoms confirmed by skin thermometry; 5 controls. Reduction of capillary density was observed in workers exposed to vibrating tools with respect to controls. Tortuosity of capillary loops was significantly more frequent in subjects exposed to vibrating tools than in controls. No statistically significant difference in capillary vessels of the hands was found between asymptomatic exposed subjects and workers affected by Raynaud-like symptoms. In our sample nailfold capillaroscopy shows good sensibilty and specificity in detecting capillary modifications secondary to exposure to hand-vibration. Weaker evidence is instead given in order to actual disturbances of hands circulation in chronic exposure to vibrating tools.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-04
... Carolina. The workers are engaged in activities related to the production of mechanic's hand tool sets. The... production of mechanic's hand tool sets to a foreign country. Based on these findings, the Department is...
Vibration-reducing gloves: transmissibility at the palm of the hand in three orthogonal directions
McDowell, Thomas W.; Dong, Ren G.; Welcome, Daniel E.; Xu, Xueyan S.; Warren, Christopher
2015-01-01
Vibration-reducing (VR) gloves are commonly used as a means to help control exposures to hand-transmitted vibrations generated by powered hand tools. The objective of this study was to characterise the vibration transmissibility spectra and frequency-weighted vibration transmissibility of VR gloves at the palm of the hand in three orthogonal directions. Seven adult males participated in the evaluation of seven glove models using a three-dimensional hand–arm vibration test system. Three levels of hand coupling force were applied in the experiment. This study found that, in general, VR gloves are most effective at reducing vibrations transmitted to the palm along the forearm direction. Gloves that are found to be superior at reducing vibrations in the forearm direction may not be more effective in the other directions when compared with other VR gloves. This casts doubts on the validity of the standardised glove screening test. Practitioner Summary This study used human subjects to measure three-dimensional vibration transmissibility of vibration-reducing gloves at the palm and identified their vibration attenuation characteristics. This study found the gloves to be most effective at reducing vibrations along the forearm direction. These gloves did not effectively attenuate vibration along the handle axial direction. PMID:24160755
Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.
Lee, Dong-Rour; Jong-Soon Kim, Laurentius
2016-08-10
The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.
Park, George D; Reed, Catherine L
2015-10-01
Despite attentional prioritization for grasping space near the hands, tool-use appears to transfer attentional bias to the tool's end/functional part. The contributions of haptic and visual inputs to attentional distribution along a tool were investigated as a function of tool-use in near (Experiment 1) and far (Experiment 2) space. Visual attention was assessed with a 50/50, go/no-go, target discrimination task, while a tool was held next to targets appearing near the tool-occupied hand or tool-end. Target response times (RTs) and sensitivity (d-prime) were measured at target locations, before and after functional tool practice for three conditions: (1) open-tool: tool-end visible (visual + haptic inputs), (2) hidden-tool: tool-end visually obscured (haptic input only), and (3) short-tool: stick missing tool's length/end (control condition: hand occupied but no visual/haptic input). In near space, both open- and hidden-tool groups showed a tool-end, attentional bias (faster RTs toward tool-end) before practice; after practice, RTs near the hand improved. In far space, the open-tool group showed no bias before practice; after practice, target RTs near the tool-end improved. However, the hidden-tool group showed a consistent tool-end bias despite practice. Lack of short-tool group results suggested that hidden-tool group results were specific to haptic inputs. In conclusion, (1) allocation of visual attention along a tool due to tool practice differs in near and far space, and (2) visual attention is drawn toward the tool's end even when visually obscured, suggesting haptic input provides sufficient information for directing attention along the tool.
Data are from Mars, Tools are from Venus
NASA Technical Reports Server (NTRS)
Lee, H. Joe
2017-01-01
Although during the data production phase, the data producers will usually ensure the products to be easily used by the specific power users the products serve. However, most data products are also posted for general public to use. It is not straightforward for data producers to anticipate what tools that these general end-data users are likely to use. In this talk, we will try to help fill in the gap by going over various tools related to Earth Science and how they work with the existing NASA HDF (Hierarchical Data Format) data products and the reasons why some products cannot be visualized or analyzed by existing tools. One goal is for to give insights for data producers on how to make their data product more interoperable. On the other hand, we also provide some hints for end users on how to make tools work with existing HDF data products. (tool category list: check the comments) HDF-EOS tools: HDFView HDF-EOS Plugin, HEG, h4tonccf, hdf-eos2 dumper, NCL, MATLAB, IDL, etc.net; CDF-Java tools: Panoply, IDV, toosUI, NcML, etc.net; CDF-C tools: ArcGIS Desktop, GrADS, NCL, NCO, etc.; GDAL tools: ArcGIS Desktop, QGIS, Google Earth, etc.; CSV tools: ArcGIS Online, MS Excel, Tableau, etc.
NASA Technical Reports Server (NTRS)
Kovarik, Madeline
1993-01-01
Intelligent computer aided training systems hold great promise for the application of this technology to mainstream education and training. Yet, this technology, which holds such a vast potential impact for the future of education and training, has had little impact beyond the enclaves of government research labs. This is largely due to the inaccessibility of the technology to those individuals in whose hands it can have the greatest impact, teachers and educators. Simply throwing technology at an educator and expecting them to use it as an effective tool is not the answer. This paper provides a background into the use of technology as a training tool. MindLink, developed by HyperTech Systems, provides trainers with a powerful rule-based tool that can be integrated directly into a Windows application. By embedding expert systems technology it becomes more accessible and easier to master.
Chosen Striking Location and the User-Tool-Environment System
ERIC Educational Resources Information Center
Wagman, Jeffrey B.; Taylor, Kona R.
2004-01-01
Controlling a hand-held tool requires that the tool user bring the tool into contact with an environmental surface in a task-appropriate manner. This, in turn, requires applying muscular forces so as to overcome how the object resists being moved about its various axes. Perceived properties of hand-held objects tend to be constrained by inertial…
ERIC Educational Resources Information Center
Sigford, Ann; Nelson, Nancy
1998-01-01
Presents a program for elementary teachers to learn how to use hand tools and household appliances to teach the principles of physics. The lesson helps teachers become familiar with simple hand tools, combat the apprehension of mechanical devices, and develop an interest in tools and technology. Session involves disassembling appliances to…
Ultrafast disk technology enables next generation micromachining laser sources
NASA Astrophysics Data System (ADS)
Heckl, Oliver H.; Weiler, Sascha; Luzius, Severin; Zawischa, Ivo; Sutter, Dirk
2013-02-01
Ultrashort pulsed lasers based on thin disk technology have entered the 100 W regime and deliver several tens of MW peak power without chirped pulse amplification. Highest uptime and insensitivity to back reflections make them ideal tools for efficient and cost effective industrial micromachining. Frequency converted versions allow the processing of a large variety of materials. On one hand, thin disk oscillators deliver more than 30 MW peak power directly out of the resonator in laboratory setups. These peak power levels are made possible by recent progress in the scaling of the pulse energy in excess of 40 μJ. At the corresponding high peak intensity, thin disk technology profits from the limited amount of material and hence the manageable nonlinearity within the resonator. Using new broadband host materials like for example the sesquioxides will eventually reduce the pulse duration during high power operation and further increase the peak power. On the other hand industry grade amplifier systems deliver even higher peak power levels. At closed-loop controlled 100W, the TruMicro Series 5000 currently offers the highest average ultrafast power in an industry proven product, and enables efficient micromachining of almost any material, in particular of glasses, ceramics or sapphire. Conventional laser cutting of these materials often requires UV laser sources with pulse durations of several nanoseconds and an average power in the 10 W range. Material processing based on high peak power laser sources makes use of multi-photon absorption processes. This highly nonlinear absorption enables micromachining driven by the fundamental (1030 nm) or frequency doubled (515 nm) wavelength of Yb:YAG. Operation in the IR or green spectral range reduces the complexity and running costs of industrial systems initially based on UV light sources. Where UV wavelength is required, the TruMicro 5360 with a specified UV crystal life-time of more than 10 thousand hours of continues operation at 15W is an excellent choice. Currently this is the world's most powerful industrial sub-10 ps UV laser.
Anthropomorphic Telemanipulation System in Terminus Control Mode
NASA Technical Reports Server (NTRS)
Jau, Bruno M.; Lewis, M. Anthony; Bejczy, Antal K.
1994-01-01
This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.
Costs and benefits of tool-use on the perception of reachable space.
Bourgeois, Jérémy; Farnè, Alessandro; Coello, Yann
2014-05-01
Previous studies have shown that using a tool modifies in a short time-scale both near-body space perception and arm-length representation in the body schema. However, to date no research has specifically investigated the effect of tool-use on an action-related perceptual task. We report here a study assessing the effect of tool-use on the perception of reachable space for perceptual estimates made in reference to either the tool or the hand. Using the tool on distal objects resulted in an extension of perceived reachable space with the tool and reduced the variability of reachability estimates. Tool use also extended perceived reachable space with the hand, but with a concomitant increase of the variability of reachability estimates. These findings suggest that tool incorporation into the represented arm following tool-use improves the anticipation of action possibilities with the tool, while hand representation becomes less accurate. Copyright © 2014 Elsevier B.V. All rights reserved.
Flynn, Kevin; Swintek, Joe; Johnson, Rodney
2017-02-01
Because of various Congressional mandates to protect the environment from endocrine disrupting chemicals (EDCs), the United States Environmental Protection Agency (USEPA) initiated the Endocrine Disruptor Screening Program. In the context of this framework, the Office of Research and Development within the USEPA developed the Medaka Extended One Generation Reproduction Test (MEOGRT) to characterize the endocrine action of a suspected EDC. One important endpoint of the MEOGRT is fecundity of medaka breeding pairs. Power analyses were conducted to determine the number of replicates needed in proposed test designs and to determine the effects that varying reproductive parameters (e.g. mean fecundity, variance, and days with no egg production) would have on the statistical power of the test. The MEOGRT Reproduction Power Analysis Tool (MRPAT) is a software tool developed to expedite these power analyses by both calculating estimates of the needed reproductive parameters (e.g. population mean and variance) and performing the power analysis under user specified scenarios. Example scenarios are detailed that highlight the importance of the reproductive parameters on statistical power. When control fecundity is increased from 21 to 38 eggs per pair per day and the variance decreased from 49 to 20, the gain in power is equivalent to increasing replication by 2.5 times. On the other hand, if 10% of the breeding pairs, including controls, do not spawn, the power to detect a 40% decrease in fecundity drops to 0.54 from nearly 0.98 when all pairs have some level of egg production. Perhaps most importantly, MRPAT was used to inform the decision making process that lead to the final recommendation of the MEOGRT to have 24 control breeding pairs and 12 breeding pairs in each exposure group. Published by Elsevier Inc.
A learning–based approach to artificial sensory feedback leads to optimal integration
Dadarlat, Maria C.; O’Doherty, Joseph E.; Sabes, Philip N.
2014-01-01
Proprioception—the sense of the body’s position in space—plays an important role in natural movement planning and execution and will likewise be necessary for successful motor prostheses and Brain–Machine Interfaces (BMIs). Here, we demonstrated that monkeys could learn to use an initially unfamiliar multi–channel intracortical microstimulation (ICMS) signal, which provided continuous information about hand position relative to an unseen target, to complete accurate reaches. Furthermore, monkeys combined this artificial signal with vision to form an optimal, minimum–variance estimate of relative hand position. These results demonstrate that a learning–based approach can be used to provide a rich artificial sensory feedback signal, suggesting a new strategy for restoring proprioception to patients using BMIs as well as a powerful new tool for studying the adaptive mechanisms of sensory integration. PMID:25420067
NASA: Biomedical applications team
NASA Technical Reports Server (NTRS)
1981-01-01
The status of projects involving the adaptation of NASA technologies for medical purposes is reviewed. Devices for the measurement of joint deformation of arthritic hands, the development of an artificial pancreas, provision of an auditory signal to avert epileptic seizures, are described along with the control of medication levels, a compressed air tank to supply power for field dentistry, and an electroencephalogram monitor. The use of the Lixiscope as a portable fluoroscope, thermal laminates for hand and foot warmers for patients with Raynaud's syndrome, and the use of absorptive coatings for instruments for controlling medication levels are described. The applicability of occupation health and safety practices to industry, computerized patient scheduling, impregnation of the common facial tissue with an agent for killing respiratory viruses, commercial applications of anthropometric data, and multispectral image analysis of the skin as a diagnostic tool are reviewed.
Rosset, Saharon; Aharoni, Ehud; Neuvirth, Hani
2014-07-01
Issues of publication bias, lack of replicability, and false discovery have long plagued the genetics community. Proper utilization of public and shared data resources presents an opportunity to ameliorate these problems. We present an approach to public database management that we term Quality Preserving Database (QPD). It enables perpetual use of the database for testing statistical hypotheses while controlling false discovery and avoiding publication bias on the one hand, and maintaining testing power on the other hand. We demonstrate it on a use case of a replication server for GWAS findings, underlining its practical utility. We argue that a shift to using QPD in managing current and future biological databases will significantly enhance the community's ability to make efficient and statistically sound use of the available data resources. © 2014 WILEY PERIODICALS, INC.
Hand anthropometry survey of rural farm workers in south-eastern Nigeria.
Obi, Okey Francis
2016-04-01
The importance of hand anthropometry as it relates to design of hand tools particularly for farm workers have been established; however, anthropometric data for this group of agricultural workers have continued to remain scarce. A survey of hand anthropometry relevant in design of agricultural hand tools was carried out on 200 male and 100 female adult farm workers in south-eastern Nigeria. Comparison of the male and female data obtained showed that male dimensions were higher than that recorded for the females. The hand anthropometric data of the male and female farm workers were compared with that of other populations but no clear distinction was observed. It was however clear that the following hand dimensions, 2nd Joint to root digit 3 and width at tip digit 3 recorded for Nigerian farm workers were highest and lowest, respectively, compared to other populations. Practitioner Summary: Hand anthropometric data relevant in design of hand tools have continued to remain scarce particularly for farm workers. Hand anthropometry survey of farm workers carried out in south-eastern Nigeria revealed higher dimensions for males than females; however, no clear distinction was observed in comparison with other populations.
Madl, Amy K; Clark, Katherine; Paustenbach, Dennis J
2007-01-01
In recent years, questions have been raised about the health risks to persons who have been occupationally exposed to asbestos-containing gaskets and packing materials used in pipes, valves, and machinery (pumps, autos, etc.). Up until the late 1970s, these materials were widely used throughout industrial and maritime operations, refineries, chemical plants, naval ships, and energy plants. Seven simulation studies and four work-site industrial hygiene studies of industrial and maritime settings involving the collection of more than 300 air samples were evaluated to determine the likely airborne fiber concentrations to which a worker may have been exposed while working with encapsulated asbestos-containing gaskets and packing materials. Each study was evaluated for the representativeness of work practices, analytical methods, sample size, and potential for asbestos contamination (e.g., insulation on valves or pipes used in the study). Specific activities evaluated included the removal and installation of gaskets and packings, flange cleaning, and gasket formation. In all but one of the studies relating to the replacement of gaskets and packing using hand-held tools, the short-term average exposures were less than the current 30-min OSHA excursion limit of 1 fiber per cubic centimeter (f/cc) and all of the long-term average exposures were less than the current 8-h permissible exposure limit time-weighted average (PEL-TWA) of 0.1 f/cc. The weight of evidence indicates that the use of hand tools and hand-operated power tools to remove or install gaskets or packing as performed by pipefitters or other tradesmen in nearly all plausible situations would not have produced airborne concentrations in excess of contemporaneous regulatory levels.
Report on the ''ESO Python Boot Camp — Pilot Version''
NASA Astrophysics Data System (ADS)
Dias, B.; Milli, J.
2017-03-01
The Python programming language is becoming very popular within the astronomical community. Python is a high-level language with multiple applications including database management, handling FITS images and tables, statistical analysis, and more advanced topics. Python is a very powerful tool both for astronomical publications and for observatory operations. Since the best way to learn a new programming language is through practice, we therefore organised a two-day hands-on workshop to share expertise among ESO colleagues. We report here the outcome and feedback from this pilot event.
Proposal for the design of a zero gravity tool storage device
NASA Technical Reports Server (NTRS)
Stuckwisch, Sue; Carrion, Carlos A.; Phillips, Lee; Laughlin, Julia; Francois, Jason
1994-01-01
Astronauts frequently use a variety of hand tools during space missions, especially on repair missions. A toolbox is needed to allow storage and retrieval of tools with minimal difficulties. The toolbox must contain tools during launch, landing, and on-orbit operations. The toolbox will be used in the Shuttle Bay and therefore must withstand the hazardous space environment. The three main functions of the toolbox in space are: to protect the tools from the space environment and from damaging one another, to allow for quick, one-handed access to the tools; and to minimize the heat transfer between the astronaut's hand and the tools. This proposal explores the primary design issues associated with the design of the toolbox. Included are the customer and design specifications, global and refined function structures, possible solution principles, concept variants, and finally design recommendations.
An IoT-Enabled Stroke Rehabilitation System Based on Smart Wearable Armband and Machine Learning
Yang, Geng; Pang, Gaoyang; Zhang, Hao; Li, Jiayi; Deng, Bin; Pang, Zhibo; Xu, Juan; Jiang, Mingzhe; Liljeberg, Pasi; Xie, Haibo; Yang, Huayong
2018-01-01
Surface electromyography signal plays an important role in hand function recovery training. In this paper, an IoT-enabled stroke rehabilitation system was introduced which was based on a smart wearable armband (SWA), machine learning (ML) algorithms, and a 3-D printed dexterous robot hand. User comfort is one of the key issues which should be addressed for wearable devices. The SWA was developed by integrating a low-power and tiny-sized IoT sensing device with textile electrodes, which can measure, pre-process, and wirelessly transmit bio-potential signals. By evenly distributing surface electrodes over user’s forearm, drawbacks of classification accuracy poor performance can be mitigated. A new method was put forward to find the optimal feature set. ML algorithms were leveraged to analyze and discriminate features of different hand movements, and their performances were appraised by classification complexity estimating algorithms and principal components analysis. According to the verification results, all nine gestures can be successfully identified with an average accuracy up to 96.20%. In addition, a 3-D printed five-finger robot hand was implemented for hand rehabilitation training purpose. Correspondingly, user’s hand movement intentions were extracted and converted into a series of commands which were used to drive motors assembled inside the dexterous robot hand. As a result, the dexterous robot hand can mimic the user’s gesture in a real-time manner, which shows the proposed system can be used as a training tool to facilitate rehabilitation process for the patients after stroke. PMID:29805919
Using homogenization, sonication and thermo-sonication to inactivate fungi
Bevilacqua, Antonio; Sinigaglia, Milena; Corbo, Maria Rosaria
2016-01-01
Ultrasound (US), Thermo-sonication (TS) and High Pressure Homogenization (HPH) were studied as tools to inactivate the spores of Penicillium spp. and Mucor spp. inoculated in distilled water. For US, the power ranged from 40% to 100%, pulse from 2 to 10 s, and duration of the treatment from 2 to 10 min. TS was performed combining US (40–80% of power, for 8 min and pulse of 2 s) with a thermal treatment (50, 55 and 60°C at 4, 8 and 12 min). Homogenization was done at 30–150 MPa for 1, 2 and 3 times. Power was the most important factors to determine the antifungal effect of US and TS towards the conidia of Penicillium spp.; on the other hand, in US treatments Mucor spp. was also affected by pulse and time. HPH exerted a significant antifungal effect only if the highest pressures were applied for 2–3 times. PMID:27375964
On the formalization of multi-scale and multi-science processes for integrative biology
Díaz-Zuccarini, Vanessa; Pichardo-Almarza, César
2011-01-01
The aim of this work is to introduce the general concept of ‘Bond Graph’ (BG) techniques applied in the context of multi-physics and multi-scale processes. BG modelling has a natural place in these developments. BGs are inherently coherent as the relationships defined between the ‘elements’ of the graph are strictly defined by causality rules and power (energy) conservation. BGs clearly show how power flows between components of the systems they represent. The ‘effort’ and ‘flow’ variables enable bidirectional information flow in the BG model. When the power level of a system is low, BGs degenerate into signal flow graphs in which information is mainly one-dimensional and power is minimal, i.e. they find a natural limitation when dealing with populations of individuals or purely kinetic models, as the concept of energy conservation in these systems is no longer relevant. The aim of this work is twofold: on the one hand, we will introduce the general concept of BG techniques applied in the context of multi-science and multi-scale models and, on the other hand, we will highlight some of the most promising features in the BG methodology by comparing with examples developed using well-established modelling techniques/software that could suggest developments or refinements to the current state-of-the-art tools, by providing a consistent framework from a structural and energetic point of view. PMID:22670211
Yun, Gi Jeong; Chun, Min Ho; Park, Ji Young; Kim, Bo Ryun
2011-06-01
To investigate the synergic effects of mirror therapy and neuromuscular electrical stimulation (NMES) for hand function in stroke patients. Sixty patients with hemiparesis after stroke were included (41 males and 19 females, average age 63.3 years). Twenty patients had NMES applied and simultaneously underwent mirror therapy. Twenty patients had NMES applied only, and twenty patients underwent mirror therapy only. Each treatment was done five days per week, 30 minutes per day, for three weeks. NMES was applied on the surface of the extensor digitorum communis and extensor pollicis brevis for open-hand motion. Muscle tone, Fugl-Meyer assessment, and power of wrist and hand were evaluated before and after treatment. There were significant improvements in the Fugl-Meyer assessment score in the wrist, hand and coordination, as well as power of wrist and hand in all groups after treatment. The mirror and NMES group showed significant improvements in the Fugl-Meyer scores of hand, wrist, coordination and power of hand extension compared to the other groups. However, the power of hand flexion, wrist flexion, and wrist extension showed no significant differences among the three groups. Muscle tone also showed no significant differences in the three groups. Our results showed that there is a synergic effect of mirror therapy and NMES on hand function. Therefore, a hand rehabilitation strategy combined with NMES and mirror therapy may be more helpful for improving hand function in stroke patients than NMES or mirror therapy only.
Lee, Sang-Yeol; Park, Yi-Jeong; Park, Hye-Min; Bae, Hae-Jin; Yu, Min-Ji; Choi, Hee-Won; Hwang, Na-Young
2014-02-01
[Purpose] This study verified the changes in muscle activities and grasping power during maximal isometric exercise of the forearm and masseter muscle with and without a mandibular orthopedic repositioning appliance (MORA). It also offers basic data for defining the correlation of function of hand with mouth. [Methods] EMG was used to measure masticatory muscle, flexor bundle and extensor bundle activities with or without MORA while subjects performed the hook grip and pinch grip. The measuring tool used for measuring grip strength was the same as that used for measuring pinch and hook strength. The subjects were 28 healthy young adults. [Result] Muscle activity and grasping power significantly increased when wearing the MORA. [Conclusion] The result indicates that wearing MORA can increase muscle activity and grasping power of forearm and masseter muscle. We think wearing MORA might help improve the function of the forearm because it activates the function of the masseter.
NASA Technical Reports Server (NTRS)
1972-01-01
A selection of new hand tools, modifications of existing tools, and techniques developed in the course of NASA research and development projects are presented. The items are presented in two sections: tools for cable and connector applications, and tools for welding applications. Safety is emphasized, together with ease of operation and use in restricted areas or hazardous environments. The discussions are directed primarily toward the technician engaged in assembly or maintenance of mechanical or electrical equipment.
Chatzigianni, Athina; Halazonetis, Demetrios J
2009-10-01
Cervical vertebrae shape has been proposed as a diagnostic factor for assessing skeletal maturation in orthodontic patients. However, evaluation of vertebral shape is mainly based on qualitative criteria. Comprehensive quantitative measurements of shape and assessments of its predictive power have not been reported. Our aims were to measure vertebral shape by using the tools of geometric morphometrics and to evaluate the correlation and predictive power of vertebral shape on skeletal maturation. Pretreatment lateral cephalograms and corresponding hand-wrist radiographs of 98 patients (40 boys, 58 girls; ages, 8.1-17.7 years) were used. Skeletal age was estimated from the hand-wrist radiographs. The first 4 vertebrae were traced, and 187 landmarks (34 fixed and 153 sliding semilandmarks) were used. Sliding semilandmarks were adjusted to minimize bending energy against the average of the sample. Principal components analysis in shape and form spaces was used for evaluating shape patterns. Shape measures, alone and combined with centroid size and age, were assessed as predictors of skeletal maturation. Shape alone could not predict skeletal maturation better than chronologic age. The best prediction was achieved with the combination of form space principal components and age, giving 90% prediction intervals of approximately 200 maturation units in the girls and 300 units in the boys. Similar predictive power could be obtained by using centroid size and age. Vertebrae C2, C3, and C4 gave similar results when examined individually or combined. C1 showed lower correlations, signifying lower integration with hand-wrist maturation. Vertebral shape is strongly correlated to skeletal age but does not offer better predictive value than chronologic age.
Laterality of Grooming and Tool Use in a Group of Captive Bonobos (Pan paniscus).
Brand, Colin M; Marchant, Linda F; Boose, Klaree J; White, Frances J; Rood, Tabatha M; Meinelt, Audra
2017-01-01
Humans exhibit population level handedness for the right hand; however, the evolution of this behavioral phenotype is poorly understood. Here, we compared the laterality of a simple task (grooming) and a complex task (tool use) to investigate whether increasing task difficulty elicited individual hand preference among a group of captive bonobos (Pan paniscus). Subjects were 17 bonobos housed at the Columbus Zoo and Aquarium. Laterality of grooming was recorded using group scans; tool use was recorded using all-occurrence sampling. Grooming was characterized as unimanual or bimanual, and both tasks were scored as right-handed or left-handed. Most individuals did not exhibit significant hand preference for unimanual or bimanual (asymmetrical hand use) grooming, although 1 individual was lateralized for each. For the 8 subjects who engaged in termite fishing enough for statistical testing, 7 individuals exhibited significant laterality and strong individual hand preference. Four subjects preferred their left hand, 3 preferred their right, and 1 had no preference. Grooming, a simple behavior, was not lateralized in this group, yet a more complex behavior revealed a strong individual hand preference, and these results are congruent with other recent findings that demonstrate complex tasks elicit hand preference in bonobos. © 2017 S. Karger AG, Basel.
Agricultural Farm-Related Injuries in Bangladesh and Convenient Design of Working Hand Tools.
Parvez, M S; Shahriar, M M
2018-01-01
Injuries during cultivation of land are the significant causes of recession for an agricultural country like Bangladesh. Thousands of tools are used in agricultural farm having much probability of getting injury at their workplaces. For the injury prevention, proper hand tool designs need to be recommended with ergonomic evaluations. This paper represents the main causes of agricultural injuries among the Bangladeshi farmers. Effective interventions had been discussed in this paper to reduce the rate of injury. This study was carried out in the Panchagarh district of Bangladesh. Data on 434 agricultural injuries were collected and recorded. About 67% injuries of all incidents were due to hand tools, and the remaining 33% were due to machinery or other sources. Though most of the injuries were not serious, about 22% injuries were greater than or equal to AIS 2 (Abbreviated Injury Scale). The practical implication of this study is to design ergonomically fit agricultural hand tools for Bangladeshi farmers in order to avoid their injuries.
Serino, Andrea; Canzoneri, Elisa; Marzolla, Marilena; di Pellegrino, Giuseppe; Magosso, Elisa
2015-01-01
Stimuli from different sensory modalities occurring on or close to the body are integrated in a multisensory representation of the space surrounding the body, i.e., peripersonal space (PPS). PPS dynamically modifies depending on experience, e.g., it extends after using a tool to reach far objects. However, the neural mechanism underlying PPS plasticity after tool use is largely unknown. Here we use a combined computational-behavioral approach to propose and test a possible mechanism accounting for PPS extension. We first present a neural network model simulating audio-tactile representation in the PPS around one hand. Simulation experiments showed that our model reproduced the main property of PPS neurons, i.e., selective multisensory response for stimuli occurring close to the hand. We used the neural network model to simulate the effects of a tool-use training. In terms of sensory inputs, tool use was conceptualized as a concurrent tactile stimulation from the hand, due to holding the tool, and an auditory stimulation from the far space, due to tool-mediated action. Results showed that after exposure to those inputs, PPS neurons responded also to multisensory stimuli far from the hand. The model thus suggests that synchronous pairing of tactile hand stimulation and auditory stimulation from the far space is sufficient to extend PPS, such as after tool-use. Such prediction was confirmed by a behavioral experiment, where we used an audio-tactile interaction paradigm to measure the boundaries of PPS representation. We found that PPS extended after synchronous tactile-hand stimulation and auditory-far stimulation in a group of healthy volunteers. Control experiments both in simulation and behavioral settings showed that the same amount of tactile and auditory inputs administered out of synchrony did not change PPS representation. We conclude by proposing a simple, biological-plausible model to explain plasticity in PPS representation after tool-use, which is supported by computational and behavioral data. PMID:25698947
Serino, Andrea; Canzoneri, Elisa; Marzolla, Marilena; di Pellegrino, Giuseppe; Magosso, Elisa
2015-01-01
Stimuli from different sensory modalities occurring on or close to the body are integrated in a multisensory representation of the space surrounding the body, i.e., peripersonal space (PPS). PPS dynamically modifies depending on experience, e.g., it extends after using a tool to reach far objects. However, the neural mechanism underlying PPS plasticity after tool use is largely unknown. Here we use a combined computational-behavioral approach to propose and test a possible mechanism accounting for PPS extension. We first present a neural network model simulating audio-tactile representation in the PPS around one hand. Simulation experiments showed that our model reproduced the main property of PPS neurons, i.e., selective multisensory response for stimuli occurring close to the hand. We used the neural network model to simulate the effects of a tool-use training. In terms of sensory inputs, tool use was conceptualized as a concurrent tactile stimulation from the hand, due to holding the tool, and an auditory stimulation from the far space, due to tool-mediated action. Results showed that after exposure to those inputs, PPS neurons responded also to multisensory stimuli far from the hand. The model thus suggests that synchronous pairing of tactile hand stimulation and auditory stimulation from the far space is sufficient to extend PPS, such as after tool-use. Such prediction was confirmed by a behavioral experiment, where we used an audio-tactile interaction paradigm to measure the boundaries of PPS representation. We found that PPS extended after synchronous tactile-hand stimulation and auditory-far stimulation in a group of healthy volunteers. Control experiments both in simulation and behavioral settings showed that the same amount of tactile and auditory inputs administered out of synchrony did not change PPS representation. We conclude by proposing a simple, biological-plausible model to explain plasticity in PPS representation after tool-use, which is supported by computational and behavioral data.
The penology of racial innocence: the erasure of racism in the study and practice of punishment.
Murakawa, Naomi; Beckett, Katherine
2010-01-01
In post–civil rights America, the ascendance of “law-and-order” politics and “postracial” ideology have given rise to what we call the penology of racial innocence. The penology of racial innocence is a framework for assessing the role of race in penal policies and institutions, one that begins with the presumption that criminal justice is innocent of racial power until proven otherwise. Countervailing sociolegal changes render this framework particularly problematic. On the one hand, the definition of racism has contracted in antidiscrimination law and in many social scientific studies of criminal justice, so that racism is defined narrowly as intentional and causally discrete harm. On the other hand, criminal justice institutions have expanded to affect historically unprecedented numbers of people of color, with penal policies broadening in ways that render the identification of racial intent and causation especially difficult. Analyses employing the penology of racial innocence examine the ever-expanding criminal justice system with limited definitions of racism, ultimately contributing to the erasure of racial power. Both racism and criminal justice operate in systemic and serpentine ways; our conceptual tools and methods, therefore, need to be equally systemic and capacious.
An Experimental Investigation of Dextrous Robots Using EVA Tools and Interfaces
NASA Technical Reports Server (NTRS)
Ambrose, Robert; Culbert, Christopher; Rehnmark, Frederik
2001-01-01
This investigation of robot capabilities with extravehicular activity (EVA) equipment looks at how improvements in dexterity are enabling robots to perform tasks once thought to be beyond machines. The approach is qualitative, using the Robonaut system at the Johnson Space Center (JSC), performing task trials that offer a quick look at this system's high degree of dexterity and the demands of EVA. Specific EVA tools attempted include tether hooks, power torque tools, and rock scoops, as well as conventional tools like scissors, wire strippers, forceps, and wrenches. More complex EVA equipment was also studied, with more complete tasks that mix tools, EVA hand rails, tethers, tools boxes, PIP pins, and EVA electrical connectors. These task trials have been ongoing over an 18 month period, as the Robonaut system evolved to its current 43 degree of freedom (DOF) configuration, soon to expand to over 50. In each case, the number of teleoperators is reported, with rough numbers of attempts and their experience level, with a subjective difficulty rating assigned to each piece of EVA equipment and function. JSC' s Robonaut system was successful with all attempted EVA hardware, suggesting new options for human and robot teams working together in space.
Pinter, Daniela; Pegritz, Sandra; Pargfrieder, Christa; Reiter, Gudrun; Wurm, Walter; Gattringer, Thomas; Linderl-Madrutter, Regina; Neuper, Claudia; Fazekas, Franz; Grieshofer, Peter; Enzinger, Christian
2013-01-01
The brain mechanisms underlying successful recovery of hand fuenction after stroke are still not fully understood, although functional MRI (fMRI) studies underline the importance of neuronal plasticity. We explored potential changes in brain activity in 7 patients with subacute to chronic stroke (69 ± 8 years) with moderate- to high-grade distal paresis of the upper limb (Motricity Index: 59.4) after standardized robotic finger-hand rehabilitation training, in addition to conventional rehabilitation therapy for 3 weeks. Behavioral and fMRI assessments were carried out before and after training to characterize changes in brain activity and behavior. The Motricity Index (pre: 59.4, post: 67.2, P < .05) and grip force (pre: 7.26, post: 11.87, P < .05) of the paretic hand increased significantly after rehabilitation. On fMRI, active movement of the affected (left) hand resulted in contralesional (ie, ipsilateral) activation of the primary sensorimotor cortex prior to rehabilitation. After rehabilitation, activation appeared "normalized," including the ipsilesional primary sensorimotor cortex and supplementary motor area (SMA). No changes and no abnormalities of activation maps were seen during movement of the unaffected hand. Subsequent region-of-interest analyses showed no significant ipsilesional activation increases after rehabilitation. Despite behavioral improvements, we failed to identify consistent patterns of functional reorganization in our sample. This warrants caution in the use of fMRI as a tool to explore neural plasticity in heterogeneous samples lacking sufficient statistical power.
Goldenberg, Georg
2013-08-01
In typical right-handed patients both apraxia and aphasia are caused by damage to the left hemisphere, which also controls the dominant right hand. In left-handed subjects the lateralities of language and of control of the dominant hand can dissociate. This permits disentangling the association of apraxia with aphasia from that with handedness. Pantomime of tool use, actual tool use and imitation of meaningless hand and finger postures were examined in 50 consecutive left-handed subjects with unilateral hemisphere lesions. There were three aphasic patients with pervasive apraxia caused by left-sided lesions. As the dominant hand is controlled by the right hemisphere, they constitute dissociations of apraxia from handedness. Conversely there were also three patients with pervasive apraxia caused by right brain lesions without aphasia. They constitute dissociations of apraxia from aphasia. Across the whole group of patients dissociations from handedness and from aphasia were observed for all manifestations of apraxia, but their frequency depended on the type of apraxia. Defective pantomime and defective tool use occurred rarely without aphasia, whereas defective imitation of hand, but not finger, postures was more frequent after right than left brain damage. The higher incidence of defective imitation of hand postures in right brain damage was mainly due to patients who had also hemi-neglect. This interaction alerts to the possibility that the association of right hemisphere damage with apraxia has to do with spatial aptitudes of the right hemisphere rather than with its control of the dominant left hand. Comparison with data from right-handed patients showed no differences between the severity of apraxia for imitation of hand or finger postures, but impairment on pantomime of tool use was milder in apraxic left-handers than in apraxic right-handers. This alleviation of the severity of apraxia corresponded with a similar alleviation of the severity of aphasia as manifested by a lower proportion of left-handed patients with global aphasia.
Hand tools: A complization. [for industrial application
NASA Technical Reports Server (NTRS)
1974-01-01
Technical information is provided for recent developments in hand tools for assembly and disassembly application, for materials finishing, and for inspection, analysis, and testing. Photographs or diagrams accompany each description and patent information is included with several articles.
Martin-Martin, Jaime; Cuesta-Vargas, Antonio I
2014-12-11
Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessment allows the clinician to know more about the motor component and its relation to movement. Therefore, the purpose of this study was the kinematic and electromyography analysis during functional hand movements. Ten subjects carried out six functional movements (terminal pinch, termino-lateral pinch, tripod pinch, power grip, extension grip and ball grip). Muscle activity (hand and forearm) was measured in real time using electromyograms, acquired with the Mega ME 6000, whilst acceleration was measured using the AcceleGlove. Electrical activity and acceleration variables were recorded simultaneously during the carrying out of the functional movements. The acceleration outcome variables were the modular vectors of each finger of the hand and the palm. In the electromyography, the main variables were normalized by the mean and by the maximum muscle activity of the thenar region, hypothenar, first interosseous dorsal, wrist flexors, carpal flexors and wrist extensors. Knowing muscle behavior allows the clinician to take a more direct approach in the treatment. Based on the results, the tripod grip shows greater kinetic activity and the middle finger is the most relevant in this regard. Ball grip involves most muscle activity, with the thenar region playing a fundamental role in hand activity. Relating muscle activation, movements, individual load and displacement offers the possibility to proceed with rehabilitation by individual component.
Ferreira, Luciane Ouriques
2013-04-01
This article presents some contrasts that exist between the discourses of public policies concerning women's health care, especially with respect to indigenous women, and the ethnological discourse which emphasizes the specificity of gender relations within indigenous societies. We worked on the assumption that the development of these public policies as well as the organization of health care services offered, which in fact are necessary, have a transforming effect on prevailing gender relations within Amerindian Societies. On the one hand, gender relations between indigenous people are associated with the domains of kinship and corporeality. On the other hand, the process of creating public policies, by means of biomedical intervention and the medicalization of the female body, constitutes a powerful tool for body modeling and the construction of subjectivities contributing to making women worthy of citizenship. The female gender is under discussion and its content is being negotiated.
Effect of shelf aging on vibration transmissibility of anti-vibration gloves
SHIBATA, Nobuyuki
2017-01-01
Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by environmental conditions such as temperature, humidity, and photo-irradiation, which cause material degradation and aging. This study focused on the influence of shelf aging on the vibration attenuation performance of air-packaged anti-vibration gloves following 2 yr of shelf aging. Effects of shelf aging on the vibration attenuation performance of anti-vibration gloves were examined according to the Japan industrial standard JIS T8114 test protocol. The findings indicate that shelf aging induces the reduction of vibration attenuation performance in air-packaged anti-vibration gloves. PMID:28978817
Discovering New Drugs on the Cellular Level
NASA Technical Reports Server (NTRS)
2005-01-01
With the Vision for Space Exploration calling for a sustained human presence in space, astronauts will need to grow plants, while in orbit, for nourishment that they will not receive from only consuming dehydrated foods. As a potential source of food for long-duration missions, space-grown plants could also give astronauts an important psychological boost, as fresh vegetables could serve as a welcomed change from monotonous meals consisting of reconstituted foods in plastic bags. Even more, these plants could likely aid in the recycling of air and wastewater on spacecraft. With a helping hand from a company by the name of Biolog, Inc., NASA is studying the impacts of decreased gravity and spaceborne bacteria on the plants being grown for food in space. With a helping hand from NASA, this very same company is creating powerful new cell- and bacteria-analysis tools for use in discovering and developing new drugs on Earth.
Design and ergonomics. Methods for integrating ergonomics at hand tool design stage.
Marsot, Jacques; Claudon, Laurent
2004-01-01
As a marked increase in the number of musculoskeletal disorders was noted in many industrialized countries and more specifically in companies that require the use of hand tools, the French National Research and Safety Institute (INRS) launched in 1999 a research project on the topic of integrating ergonomics into hand tool design, and more particularly to a design of a boning knife. After a brief recall of the difficulties of integrating ergonomics at the design stage, the present paper shows how 3 design methodological tools--Functional Analysis, Quality Function Deployment and TRIZ--have been applied to the design of a boning knife. Implementation of these tools enabled us to demonstrate the extent to which they are capable of responding to the difficulties of integrating ergonomics into product design.
Some lemma on spectrum of eigen value regarding power method
NASA Astrophysics Data System (ADS)
Jamali, A. R. M. Jalal Uddin; Alam, Md. Sah
2017-04-01
Eigen value problems arise in almost all science and engineering fields. There exist some smart methods in literature in which most of them are able to find only Eigen values but could not find corresponding Eigen vectors. There exist many engineering as well as scientific fields in which both largest as well as smallest Eigen pairs are required. Power method is very simple but a powerful tool for finding largest Eigen value and corresponding Eigen vector (Eigen-pair). Again Inverse Power method is applied to find out smallest Eigen-pair and/or desire Eigen-pairs. But it is known that Inverse Power method is computationally very costly. On the other hand by using shifting property, Power method can find further Eigen-pairs. But the position of this Eigen value in the set of spectrum of the Eigen values is not identified. In this regard we proposed four lemma associate with Modified Power method. Each Lemma is proved ornately. The Modified Power method is implemented and illustrates an example for the verification of the Lemma. By using lemma the modified power algorithm is able to find out both largest and smallest Eigen-pairs successfully and efficiently in some cases. Moreover by the help of the Lemma, algorithm is able to detect the nature (positive and negative) of the Eigen values.
ERIC Educational Resources Information Center
Magosso, Elisa; Ursino, Mauro; di Pellegrino, Giuseppe; Ladavas, Elisabetta; Serino, Andrea
2010-01-01
Visual peripersonal space (i.e., the space immediately surrounding the body) is represented by multimodal neurons integrating tactile stimuli applied on a body part with visual stimuli delivered near the same body part, e.g., the hand. Tool use may modify the boundaries of the peri-hand area, where vision and touch are integrated. The neural…
First Person Experience of Body Transfer in Virtual Reality
Slater, Mel; Spanlang, Bernhard; Sanchez-Vives, Maria V.; Blanke, Olaf
2010-01-01
Background Altering the normal association between touch and its visual correlate can result in the illusory perception of a fake limb as part of our own body. Thus, when touch is seen to be applied to a rubber hand while felt synchronously on the corresponding hidden real hand, an illusion of ownership of the rubber hand usually occurs. The illusion has also been demonstrated using visuomotor correlation between the movements of the hidden real hand and the seen fake hand. This type of paradigm has been used with respect to the whole body generating out-of-the-body and body substitution illusions. However, such studies have only ever manipulated a single factor and although they used a form of virtual reality have not exploited the power of immersive virtual reality (IVR) to produce radical transformations in body ownership. Principal Findings Here we show that a first person perspective of a life-sized virtual human female body that appears to substitute the male subjects' own bodies was sufficient to generate a body transfer illusion. This was demonstrated subjectively by questionnaire and physiologically through heart-rate deceleration in response to a threat to the virtual body. This finding is in contrast to earlier experimental studies that assume visuotactile synchrony to be the critical contributory factor in ownership illusions. Our finding was possible because IVR allowed us to use a novel experimental design for this type of problem with three independent binary factors: (i) perspective position (first or third), (ii) synchronous or asynchronous mirror reflections and (iii) synchrony or asynchrony between felt and seen touch. Conclusions The results support the notion that bottom-up perceptual mechanisms can temporarily override top down knowledge resulting in a radical illusion of transfer of body ownership. The research also illustrates immersive virtual reality as a powerful tool in the study of body representation and experience, since it supports experimental manipulations that would otherwise be infeasible, with the technology being mature enough to represent human bodies and their motion. PMID:20485681
Pilot study of digital tools to support multimodal hand hygiene in a clinical setting.
Thirkell, Gary; Chambers, Joanne; Gilbart, Wayne; Thornhill, Kerrill; Arbogast, James; Lacey, Gerard
2018-03-01
Digital tools for hand hygiene do not share data, limiting their potential to support multimodal programs. The Christie NHS Foundation Trust, United Kingdom, worked with GOJO (in the United States), MEG (in Ireland), and SureWash (in Ireland) to integrate their systems and pilot their combined use in a clinical setting. A 28-bed medical oncology unit piloted the system for 5 weeks. Live data from the tools were combined to create a novel combined risk status metric that was displayed publicly and via a management Web site. The combined risk status reduced over the pilot period. However, larger and longer duration studies are required to reach statistical significance. Staff and especially patient reaction was positive in that 70% of the hand hygiene training events were by patients. The digital tools did not negatively impact clinical workflow and received positive engagement from staff and patients. The combined risk status did not change significantly over the short pilot period because there was also no specific hand hygiene improvement campaign underway at the time of the pilot study. The results indicate that integrated digital tools can provide both rich data and novel tools that both measure impact and provide feedback to support the implementation of multimodal hand hygiene campaigns, reducing the need for significant additional personnel resources. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
Lehotsky, Ákos; Morvai, Júlia; Szilágyi, László; Bánsághi, Száva; Benkó, Alíz; Haidegger, Tamás
2017-07-01
Hand hygiene is probably the most effective tool of nosocomial infection prevention, however, proper feedback and control is needed to develop the individual hand hygiene practice. Assessing the efficiency of modern education tools, and digital demonstration and verification equipment during their wide-range deployment. 1269 healthcare workers took part in a training organized by our team. The training included the assessment of the participants' hand hygiene technique to identify the most often missed areas. The hand hygiene technique was examined by a digital device. 33% of the participants disinfected their hands incorrectly. The most often missed sites are the fingertips (33% on the left hand, 37% on the right hand) and the thumbs (42% on the left hand, 32% on the right hand). The feedback has a fundamental role in the development of the hand hygiene technique. With the usage of electronic devices feedback can be provided efficiently and simply. Orv Hetil. 2017; 158(29): 1143-1148.
Rossol, Nathaniel; Cheng, Irene; Rui Shen; Basu, Anup
2014-01-01
Real-time control of visual display systems via mid-air hand gestures offers many advantages over traditional interaction modalities. In medicine, for example, it allows a practitioner to adjust display values, e.g. contrast or zoom, on a medical visualization interface without the need to re-sterilize the interface. However, when users are holding a small tool (such as a pen, surgical needle, or computer stylus) the need to constantly put the tool down in order to make hand gesture interactions is not ideal. This work presents a novel interface that automatically adjusts for gesturing with hands and hand-held tools to precisely control medical displays. The novelty of our interface is that it uses a single set of gestures designed to be equally effective for fingers and hand-held tools without using markers. This type of interface was previously not feasible with low-resolution depth sensors such as Kinect, but is now achieved by using the recently released Leap Motion controller. Our interface is validated through a user study on a group of people given the task of adjusting parameters on a medical image.
Moro, Maria Luisa; Morsillo, Filomena; Nascetti, Simona; Parenti, Mita; Allegranzi, Benedetta; Pompa, Maria Grazia; Pittet, Didier
2017-01-01
A national hand hygiene promotion campaign based on the World Health Organization (WHO) multimodal, Clean Care is Safer Care campaign was launched in Italy in 2007. One hundred seventy-five hospitals from 14 of 20 Italian regions participated. Data were collected using methods and tools provided by the WHO campaign, translated into Italian. Hand hygiene compliance, ward infrastructure, and healthcare workers’ knowledge and perception of healthcare-associated infections and hand hygiene were evaluated before and after campaign implementation. Compliance data from the 65 hospitals returning complete data for all implementation tools were analysed using a multilevel approach. Overall, hand hygiene compliance increased in the 65 hospitals from 40% to 63% (absolute increase: 23%, 95% confidence interval: 22–24%). A wide variation in hand hygiene compliance among wards was observed; inter-ward variability significantly decreased after campaign implementation and the level of perception was the only item associated with this. Long-term sustainability in 48 of these 65 hospitals was assessed in 2014 using the WHO Hand Hygiene Self-Assessment Framework tool. Of the 48 hospitals, 44 scored in the advanced/intermediate categories of hand hygiene implementation progress. The median hand hygiene compliance achieved at the end of the 2007–2008 campaign appeared to be sustained in 2014. PMID:28661390
Ensuring Patient Safety in Care Transitions: An Empirical Evaluation of a Handoff Intervention Tool
Abraham, Joanna; Kannampallil, Thomas; Patel, Bela; Almoosa, Khalid; Patel, Vimla L.
2012-01-01
Successful handoffs ensure smooth, efficient and safe patient care transitions. Tools and systems designed for standardization of clinician handoffs often focuses on ensuring the communication activity during transitions, with limited support for preparatory activities such as information seeking and organization. We designed and evaluated a Handoff Intervention Tool (HAND-IT) based on a checklist-inspired, body system format allowing structured information organization, and a problem-case narrative format allowing temporal description of patient care events. Based on a pre-post prospective study using a multi-method analysis we evaluated the effectiveness of HAND-IT as a documentation tool. We found that the use of HAND-IT led to fewer transition breakdowns, greater tool resilience, and likely led to better learning outcomes for less-experienced clinicians when compared to the current tool. We discuss the implications of our results for improving patient safety with a continuity of care-based approach. PMID:23304268
Improving physician's hand over among oncology staff using standardized communication tool
Alolayan, Ashwaq; Alkaiyat, Mohammad; Ali, Yosra; Alshami, Mona; Al-Surimi, Khaled; Jazieh, Abdul-Rahman
2017-01-01
Cancer patients are frequently admitted to hospital for many reasons. During their hospitalization they are handled by different physicians and other care providers. Maintaining good communication among physicians is essential to assure patient safety and the delivery of quality patient care. Several incidents of miscommunication issues have been reported due to lack of a standardized communication tool for patients' hand over among physicians at our oncology department. Hence, this improvement project aims at assessing the impact of using a standardized communication tool on improving patients' hand over and quality of patient care. A quality improvement team has been formed to address the issue of cancer patients' hand over. We adopted specific hand over tool to be used by physicians. This tool was developed based on well-known and validated communication tool called ISBAR - Identify, Situation, Background, Assessment and Recommendation, which contains pertinent information about the patient's condition. The form should be shared at a specific point in time during the handover process. We monitored the compliance of physician's with this tool over 16 weeks embedded by four ‘purposive’ and ‘sequential’ Plan-Do-Study-Act (PDSA) cycles; where each PDSA cycle was developed based on the challenges faced and lessons learned in each step and the result of the previous PDSA cycle. Physicians compliance rate of using the tool had improved significantly from 45% (baseline) to 100% after the fourth PDSA cycle. Other process measure was measuring acknowledgment of hand over receipt email at two checkpoints at 8:00 – 9:00 a.m. and 4:00 – 5:00 p.m. The project showed that using a standardized handover form as a daily communication method between physicians is a useful idea and feasible to improve cancer patients handover with positive impact on many aspects of healthcare process and outcomes. PMID:28174657
Unsteady computational fluid dynamics in front crawl swimming.
Samson, Mathias; Bernard, Anthony; Monnet, Tony; Lacouture, Patrick; David, Laurent
2017-05-01
The development of codes and power calculations currently allows the simulation of increasingly complex flows, especially in the turbulent regime. Swimming research should benefit from these technological advances to try to better understand the dynamic mechanisms involved in swimming. An unsteady Computational Fluid Dynamics (CFD) study is conducted in crawl, in order to analyse the propulsive forces generated by the hand and forearm. The k-ω SST turbulence model and an overset grid method have been used. The main objectives are to analyse the evolution of the hand-forearm propulsive forces and to explain this relative to the arm kinematics parameters. In order to validate our simulation model, the calculated forces and pressures were compared with several other experimental and numerical studies. A good agreement is found between our results and those of other studies. The hand is the segment that generates the most propulsive forces during the aquatic stroke. As the pressure component is the main source of force, the orientation of the hand-forearm in the absolute coordinate system is an important kinematic parameter in the swimming performance. The propulsive forces are biggest when the angles of attack are high. CFD appears as a very valuable tool to better analyze the mechanisms of swimming performance and offers some promising developments, especially for optimizing the performance from a parametric study.
Department of Energy Construction Safety Reference Guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-09-01
DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.
NASA Technical Reports Server (NTRS)
Casey, E. J.; Commadore, C. C.; Ingles, M. E.
1980-01-01
Long wire bundles twist into uniform spiral harnesses with help of simple apparatus. Wires pass through spacers and through hand-held tool with hole for each wire. Ends are attached to low speed bench motor. As motor turns, operator moves hand tool away forming smooth twists in wires between motor and tool. Technique produces harnesses that generate less radio-frequency interference than do irregularly twisted cables.
A Network Selection Algorithm Considering Power Consumption in Hybrid Wireless Networks
NASA Astrophysics Data System (ADS)
Joe, Inwhee; Kim, Won-Tae; Hong, Seokjoon
In this paper, we propose a novel network selection algorithm considering power consumption in hybrid wireless networks for vertical handover. CDMA, WiBro, WLAN networks are candidate networks for this selection algorithm. This algorithm is composed of the power consumption prediction algorithm and the final network selection algorithm. The power consumption prediction algorithm estimates the expected lifetime of the mobile station based on the current battery level, traffic class and power consumption for each network interface card of the mobile station. If the expected lifetime of the mobile station in a certain network is not long enough compared the handover delay, this particular network will be removed from the candidate network list, thereby preventing unnecessary handovers in the preprocessing procedure. On the other hand, the final network selection algorithm consists of AHP (Analytic Hierarchical Process) and GRA (Grey Relational Analysis). The global factors of the network selection structure are QoS, cost and lifetime. If user preference is lifetime, our selection algorithm selects the network that offers longest service duration due to low power consumption. Also, we conduct some simulations using the OPNET simulation tool. The simulation results show that the proposed algorithm provides longer lifetime in the hybrid wireless network environment.
Comparison of shoulder load during power-assisted and purely hand-rim wheelchair propulsion.
Kloosterman, Marieke G M; Eising, Hilde; Schaake, Leendert; Buurke, Jaap H; Rietman, Johan S
2012-06-01
Repetitive forces and moments are among the work requirements of hand-rim wheelchair propulsion that are related to shoulder injuries. No previous research has been published about the influence of power-assisted wheelchair propulsion on these work requirements. The purpose of our study was therefore to determine the influence of power-assisted propulsion on shoulder biomechanics and muscle activation patterns. We also explored the theoretical framework for the effectiveness of power-assisted propulsion in preventing shoulder injuries by decreasing the work requirements of hand-rim wheelchair propulsion. Nine non-wheelchair users propelled a hand-rim wheelchair on a treadmill at 0.9 m/s. Shoulder biomechanics, and muscle activation patterns, were compared between propulsion with and without power-assist. Propulsion frequency did not differ significantly between the two conditions (Wilcoxon Signed Rank test/significance level/effect size:4/.314/-.34). During power-assisted propulsion we found significantly decreased maximum shoulder flexion and internal rotation angles (1/.015/-.81 and 0/.008/-.89) and decreased peak force on the rim (0/.008/-.89). This resulted in decreased shoulder flexion, adduction and internal rotation moments (2/.021/-.77; 0/.008/-.89 and 1/.011/-.85) and decreased forces at the shoulder in the posterior, superior and lateral directions (2/.021/-.77; 2/.008/-.89 and 2/.024/-.75). Muscle activation in the pectoralis major, posterior deltoid and triceps brachii was also decreased (2/.038/-.69; 1/.015/-.81 and 1/.021/-.77). Power-assist influenced the work requirements of hand-rim wheelchair propulsion by healthy subjects. It was primarily the kinetics at rim and shoulder which were influenced by power-assisted propulsion. Additional research with actual hand-rim wheelchair users is required before extrapolation to routine clinical practice. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kazama, Toshiharu; Hanajima, Naohiko; Shimizu, Kazumichi; Satoh, Kohki
To foster engineers with creative power, Muroran Institute of Technology established Manufacturing and Engineering Design Center (MEDeC) that concentrates on Monozukuri. MEDeC consists of three project groups : i) Education Support Group provides educational support for practical training classes on and off campus and PDCA (plan-do-check-action) -conscious engineering design education related to Monozukuri ; ii) Fundamental Manufacturing Research Group carries out nurture research into fundamental and innovative technology of machining and manufacturing, and iii) Regional Cooperation Group coordinates the activities in cooperation with bureau, schools and industries in and around Muroran City. MEDeC has a fully integrated collection of machine tools and hand tools for manufacturing, an atelier, a tatara workplace, implements for measurement and related equipment designed for practically teaching state-of-the-practice manufacturing methods.
Optimal visual-haptic integration with articulated tools.
Takahashi, Chie; Watt, Simon J
2017-05-01
When we feel and see an object, the nervous system integrates visual and haptic information optimally, exploiting the redundancy in multiple signals to estimate properties more precisely than is possible from either signal alone. We examined whether optimal integration is similarly achieved when using articulated tools. Such tools (tongs, pliers, etc) are a defining characteristic of human hand function, but complicate the classical sensory 'correspondence problem' underlying multisensory integration. Optimal integration requires establishing the relationship between signals acquired by different sensors (hand and eye) and, therefore, in fundamentally unrelated units. The system must also determine when signals refer to the same property of the world-seeing and feeling the same thing-and only integrate those that do. This could be achieved by comparing the pattern of current visual and haptic input to known statistics of their normal relationship. Articulated tools disrupt this relationship, however, by altering the geometrical relationship between object properties and hand posture (the haptic signal). We examined whether different tool configurations are taken into account in visual-haptic integration. We indexed integration by measuring the precision of size estimates, and compared our results to optimal predictions from a maximum-likelihood integrator. Integration was near optimal, independent of tool configuration/hand posture, provided that visual and haptic signals referred to the same object in the world. Thus, sensory correspondence was determined correctly (trial-by-trial), taking tool configuration into account. This reveals highly flexible multisensory integration underlying tool use, consistent with the brain constructing internal models of tools' properties.
Modeling and simulation of biological systems using SPICE language
Lallement, Christophe; Haiech, Jacques
2017-01-01
The article deals with BB-SPICE (SPICE for Biochemical and Biological Systems), an extension of the famous Simulation Program with Integrated Circuit Emphasis (SPICE). BB-SPICE environment is composed of three modules: a new textual and compact description formalism for biological systems, a converter that handles this description and generates the SPICE netlist of the equivalent electronic circuit and NGSPICE which is an open-source SPICE simulator. In addition, the environment provides back and forth interfaces with SBML (System Biology Markup Language), a very common description language used in systems biology. BB-SPICE has been developed in order to bridge the gap between the simulation of biological systems on the one hand and electronics circuits on the other hand. Thus, it is suitable for applications at the interface between both domains, such as development of design tools for synthetic biology and for the virtual prototyping of biosensors and lab-on-chip. Simulation results obtained with BB-SPICE and COPASI (an open-source software used for the simulation of biochemical systems) have been compared on a benchmark of models commonly used in systems biology. Results are in accordance from a quantitative viewpoint but BB-SPICE outclasses COPASI by 1 to 3 orders of magnitude regarding the computation time. Moreover, as our software is based on NGSPICE, it could take profit of incoming updates such as the GPU implementation, of the coupling with powerful analysis and verification tools or of the integration in design automation tools (synthetic biology). PMID:28787027
Compact and low-cost humanoid hand powered by nylon artificial muscles.
Wu, Lianjun; Jung de Andrade, Monica; Saharan, Lokesh Kumar; Rome, Richard Steven; Baughman, Ray H; Tadesse, Yonas
2017-02-03
This paper focuses on design, fabrication and characterization of a biomimetic, compact, low-cost and lightweight 3D printed humanoid hand (TCP Hand) that is actuated by twisted and coiled polymeric (TCP) artificial muscles. The TCP muscles were recently introduced and provided unprecedented strain, mechanical work, and lifecycle (Haines et al 2014 Science 343 868-72). The five-fingered humanoid hand is under-actuated and has 16 degrees of freedom (DOF) in total (15 for fingers and 1 at the palm). In the under-actuated hand designs, a single actuator provides coupled motions at the phalanges of each finger. Two different designs are presented along with the essential elements consisting of actuators, springs, tendons and guide systems. Experiments were conducted to investigate the performance of the TCP muscles in response to the power input (power magnitude, type of wave form such as pulsed or square wave, and pulse duration) and the resulting actuation stroke and force generation. A kinematic model of the flexor tendons was developed to simulate the flexion motion and compare with experimental results. For fast finger movements, short high-power pulses were employed. Finally, we demonstrated the grasping of various objects using the humanoid TCP hand showing an array of functions similar to a natural hand.
ERIC Educational Resources Information Center
Bowyer, James
2015-01-01
Four components of the Kodály concept are delineated here: philosophy, objectives, essential tools, and lesson planning process. After outlining the tenets of the Kodály philosophy and objectives, the article presents the Kodály concept's essential tools, including singing, movable "do" solfège, rhythm syllables, hand signs, singing on…
Moro, Maria Luisa; Morsillo, Filomena; Nascetti, Simona; Parenti, Mita; Allegranzi, Benedetta; Pompa, Maria Grazia; Pittet, Didier
2017-06-08
A national hand hygiene promotion campaign based on the World Health Organization (WHO) multimodal, Clean Care is Safer Care campaign was launched in Italy in 2007. One hundred seventy-five hospitals from 14 of 20 Italian regions participated. Data were collected using methods and tools provided by the WHO campaign, translated into Italian. Hand hygiene compliance, ward infrastructure, and healthcare workers' knowledge and perception of healthcare-associated infections and hand hygiene were evaluated before and after campaign implementation. Compliance data from the 65 hospitals returning complete data for all implementation tools were analysed using a multilevel approach. Overall, hand hygiene compliance increased in the 65 hospitals from 40% to 63% (absolute increase: 23%, 95% confidence interval: 22-24%). A wide variation in hand hygiene compliance among wards was observed; inter-ward variability significantly decreased after campaign implementation and the level of perception was the only item associated with this. Long-term sustainability in 48 of these 65 hospitals was assessed in 2014 using the WHO Hand Hygiene Self-Assessment Framework tool. Of the 48 hospitals, 44 scored in the advanced/intermediate categories of hand hygiene implementation progress. The median hand hygiene compliance achieved at the end of the 2007-2008 campaign appeared to be sustained in 2014. This article is copyright of The Authors, 2017.
Almeida, Jorge; Amaral, Lénia; Garcea, Frank E; Aguiar de Sousa, Diana; Xu, Shan; Mahon, Bradford Z; Martins, Isabel Pavão
2018-05-24
A major principle of organization of the visual system is between a dorsal stream that processes visuomotor information and a ventral stream that supports object recognition. Most research has focused on dissociating processing across these two streams. Here we focus on how the two streams interact. We tested neurologically-intact and impaired participants in an object categorization task over two classes of objects that depend on processing within both streams-hands and tools. We measured how unconscious processing of images from one of these categories (e.g., tools) affects the recognition of images from the other category (i.e., hands). Our findings with neurologically-intact participants demonstrated that processing an image of a hand hampers the subsequent processing of an image of a tool, and vice versa. These results were not present in apraxic patients (N = 3). These findings suggest local and global inhibitory processes working in tandem to co-register information across the two streams.
Unusual hand postures but not familiar tools show motor equivalence with precision grasping.
Tang, Rixin; Whitwell, Robert L; Goodale, Melvyn A
2016-06-01
A central question in sensorimotor control is whether or not actions performed with the hands and corresponding actions performed with tools share a common underlying motor plan, even though different muscles and effectors are engaged. There is certainly evidence that tools used to extend the reach of the limb can be incorporated into the body schema after training. But even so, it is not clear whether or not actions such as grasping with tools and grasping with the fingers share the same programming network, i.e. show 'motor equivalence'. Here we first show that feedback-appropriate motor programming for grasps with atypical hand postures readily transfers to stereotypical precision grasps. In stark contrast, however, we find no evidence for an analogous transfer of the programming for grasps using tools to the same stereotypical precision grasps. These findings have important implications for our understanding of body schema. Although the extension of the limb that is afforded by tool use may be incorporated into the body schema, the programming of a grasping movement made with tools appears to resist such incorporation. It could be the case that the proprioceptive signals from the limb can be easily updated to reflect the end of a tool held in the hand, but the motor programs and sensory signals associated with grasping with the thumb and finger cannot be easily adapted to control the opening and closing of a tool. Instead, new but well-practiced motor programs are put in place for tool use that do not exhibit motor equivalence with manual grasping. Copyright © 2016 Elsevier B.V. All rights reserved.
Mosquera, M.; Geribàs, N.; Bargalló, A.; Llorente, M.; Riba, D.
2012-01-01
Clear hand laterality patterns in humans are widely accepted. However, humans only elicit a significant hand laterality pattern when performing complementary role differentiation (CRD) tasks. Meanwhile, hand laterality in chimpanzees is weaker and controversial. Here we have reevaluated our results on hand laterality in chimpanzees housed in naturalistic environments at Fundació Mona (Spain) and Chimfunshi Wild Orphanage (Zambia). Our results show that the difference between hand laterality in humans and chimpanzees is not as great as once thought. Furthermore, we found a link between hand laterality and task complexity and also an even more interesting connection: CRD tasks elicited not only the hand laterality but also the use of tools. This paper aims to turn attention to the importance of this threefold connection in human evolution: the link between CRD tasks, hand laterality, and tool use, which has important evolutionary implications that may explain the development of complex behaviour in early hominins. PMID:22550466
Mosquera, M; Geribàs, N; Bargalló, A; Llorente, M; Riba, D
2012-01-01
Clear hand laterality patterns in humans are widely accepted. However, humans only elicit a significant hand laterality pattern when performing complementary role differentiation (CRD) tasks. Meanwhile, hand laterality in chimpanzees is weaker and controversial. Here we have reevaluated our results on hand laterality in chimpanzees housed in naturalistic environments at Fundació Mona (Spain) and Chimfunshi Wild Orphanage (Zambia). Our results show that the difference between hand laterality in humans and chimpanzees is not as great as once thought. Furthermore, we found a link between hand laterality and task complexity and also an even more interesting connection: CRD tasks elicited not only the hand laterality but also the use of tools. This paper aims to turn attention to the importance of this threefold connection in human evolution: the link between CRD tasks, hand laterality, and tool use, which has important evolutionary implications that may explain the development of complex behaviour in early hominins.
Venson, José Eduardo; Bevilacqua, Fernando; Berni, Jean; Onuki, Fabio; Maciel, Anderson
2018-05-01
Mobile devices and software are now available with sufficient computing power, speed and complexity to allow for real-time interpretation of radiology exams. In this paper, we perform a multivariable user study that investigates concordance of image-based diagnoses provided using mobile devices on the one hand and conventional workstations on the other hand. We performed a between-subjects task-analysis using CT, MRI and radiography datasets. Moreover, we investigated the adequacy of the screen size, image quality, usability and the availability of the tools necessary for the analysis. Radiologists, members of several teams, participated in the experiment under real work conditions. A total of 64 studies with 93 main diagnoses were analyzed. Our results showed that 56 cases were classified with complete concordance (87.69%), 5 cases with almost complete concordance (7.69%) and 1 case (1.56%) with partial concordance. Only 2 studies presented discordance between the reports (3.07%). The main reason to explain the cause of those disagreements was the lack of multiplanar reconstruction tool in the mobile viewer. Screen size and image quality had no direct impact on the mobile diagnosis process. We concluded that for images from emergency modalities, a mobile interface provides accurate interpretation and swift response, which could benefit patients' healthcare. Copyright © 2018 Elsevier B.V. All rights reserved.
Kloosterman, Marieke G M; Buurke, Jaap H; de Vries, Wiebe; Van der Woude, Lucas H V; Rietman, Johan S
2015-10-01
This study aims to compare hand-rim and power-assisted hand-rim propulsion on potential risk factors for shoulder overuse injuries: intensity and repetition of shoulder loading and force generation in the extremes of shoulder motion. Eleven experienced hand-rim wheelchair users propelled an instrumented wheelchair on a treadmill while upper-extremity kinematic, kinetic and surface electromyographical data was collected during propulsion with and without power-assist. As a result during power-assisted propulsion the peak resultant force exerted at the hand-rim decreased and was performed with significantly less abduction and internal rotation at the shoulder. At shoulder level the anterior directed force and internal rotation and flexion moments decreased significantly. In addition, posterior and the minimal inferior directed forces and the external rotation moment significantly increased. The stroke angle decreased significantly, as did maximum shoulder flexion, extension, abduction and internal rotation. Stroke-frequency significantly increased. Muscle activation in the anterior deltoid and pectoralis major also decreased significantly. In conclusion, compared to hand-rim propulsion power-assisted propulsion seems effective in reducing potential risk factors of overuse injuries with the highest gain on decreased range of motion of the shoulder joint, lower peak propulsion force on the rim and reduced muscle activity. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Prosthetic Hand For Holding Rods, Tools, And Handles
NASA Technical Reports Server (NTRS)
Belcher, Jewell G., Jr.; Vest, Thomas W.
1995-01-01
Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.
76 FR 50755 - Heavy Forged Hand Tools From China
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-16
... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 731-TA-457-A-D (Third Review)] Heavy Forged... heavy forged hand tools from China would be likely to lead to continuation or recurrence of material.... The views of the Commission are contained in USITC Publication 4250 (August 2011), entitled Heavy...
Coenen, Michaela; Rudolf, Klaus-Dieter; Kus, Sandra; Dereskewitz, Caroline
2018-05-24
The International Classification of Functioning, Disability and Health (ICF) provides a standardized language of almost 1500 ICF categories for coding information about functioning and contextual factors. Short lists (ICF Core Sets) are helpful tools to support the implementation of the ICF in clinical routine. In this paper we report on the implementation of ICF Core Sets in clinical routine using the "ICF Core Sets for Hand Conditions" and the "Lighthouse Project Hand" as an example. Based on the ICF categories of the "Brief ICF Core Set for Hand Conditions", the ICF-based assessment tool (ICF Hand A ) was developed aiming to guide the assessment and treatment of patients with injuries and diseases located at the hand. The ICF Hand A facilitates the standardized assessment of functioning - taking into consideration of a holistic view of the patients - along the continuum of care ranging from acute care to rehabilitation and return to work. Reference points for the assessment of the ICF Hand A are determined in treatment guidelines for selected injuries and diseases of the hand along with recommendations for acute treatment and care, procedures and interventions of subsequent treatment and rehabilitation. The assessment of the ICF Hand A according to the defined reference points can be done using electronic clinical assessment tools and allows for an automatic generation of a timely medical report of a patient's functioning. In the future, the ICF Hand A can be used to inform the coding of functioning in ICD-11.
Electromechanical hand incorporates touch sensors and trigger function
NASA Technical Reports Server (NTRS)
Dane, D. H.
1970-01-01
Electromechanical hand incorporates touch sensors, concealed fingers, and a structure that allows the hand to hold a tool on a flat surface. The hands can be mounted on most types of existing manipulators either directly or by means of modified mounting brackets.
Perceptual attraction in tool use: evidence for a reliability-based weighting mechanism.
Debats, Nienke B; Ernst, Marc O; Heuer, Herbert
2017-04-01
Humans are well able to operate tools whereby their hand movement is linked, via a kinematic transformation, to a spatially distant object moving in a separate plane of motion. An everyday example is controlling a cursor on a computer monitor. Despite these separate reference frames, the perceived positions of the hand and the object were found to be biased toward each other. We propose that this perceptual attraction is based on the principles by which the brain integrates redundant sensory information of single objects or events, known as optimal multisensory integration. That is, 1 ) sensory information about the hand and the tool are weighted according to their relative reliability (i.e., inverse variances), and 2 ) the unisensory reliabilities sum up in the integrated estimate. We assessed whether perceptual attraction is consistent with optimal multisensory integration model predictions. We used a cursor-control tool-use task in which we manipulated the relative reliability of the unisensory hand and cursor position estimates. The perceptual biases shifted according to these relative reliabilities, with an additional bias due to contextual factors that were present in experiment 1 but not in experiment 2 The biased position judgments' variances were, however, systematically larger than the predicted optimal variances. Our findings suggest that the perceptual attraction in tool use results from a reliability-based weighting mechanism similar to optimal multisensory integration, but that certain boundary conditions for optimality might not be satisfied. NEW & NOTEWORTHY Kinematic tool use is associated with a perceptual attraction between the spatially separated hand and the effective part of the tool. We provide a formal account for this phenomenon, thereby showing that the process behind it is similar to optimal integration of sensory information relating to single objects. Copyright © 2017 the American Physiological Society.
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
30 CFR 56.12033 - Hand-held electric tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...
48 CFR 218.201 - Contingency operation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... hours of business related courses do not apply to DoD employees or members of the armed forces who are....7002, Restrictions on food, clothing, fabrics, specialty metals, and hand or measuring tools: (1... hand or measuring tools in support of contingency operations, or for which the use of other than...
48 CFR 218.201 - Contingency operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hours of business related courses do not apply to DoD employees or members of the armed forces who are....7002, Restrictions on food, clothing, fabrics, specialty metals, and hand or measuring tools: (1... hand or measuring tools in support of contingency operations, or for which the use of other than...
Component separation for cosmic microwave background radiation
NASA Astrophysics Data System (ADS)
Fernández-Cobos, R.; Vielva, P.; Barreiro, R. B.; Martínez-González, E.
2011-11-01
Cosmic microwave background (CMB) radiation data obtained by different experiments contains, besides the desired signal, a superposition of microwave sky contributions mainly due to, on the one hand, synchrotron radiation, free-free emission and re-emission of dust clouds in our galaxy; and, on the other hand, extragalactic sources. We present an analytical method, using a wavelet decomposition on the sphere, to recover the CMB signal from microwave maps. Being applied to both temperature and polarization data, it is shown as a significant powerful tool when it is used in particularly polluted regions of the sky. The applied wavelet has the advantages of requiring little computering time in its calculations being adapted to the HEALPix pixelization scheme (which is the format that the community uses to report the CMB data) and offering the possibility of multi-resolution analysis. The decomposition is implemented as part of a template fitting method, minimizing the variance of the resulting map. The method was tested with simulations of WMAP data and results have been positive, with improvements up to 12% in the variance of the resulting full sky map and about 3% in low contaminate regions. Finally, we also present some preliminary results with WMAP data in the form of an angular cross power spectrum C_ℓ^{TE}, consistent with the spectrum offered by WMAP team.
Vibration syndrome in railway track maintenance workers.
Virokannas, H; Anttonen, H; Niskanen, J
1995-01-01
An inquiry was sent to all railway maintenance workers in three railway districts in Finland and hand-arm vibration was measured on the handlebars of tools used by maintenance workers. The study group included 252 (82%) subjects, whose mean age was 41 years and who had worked in track maintenance for 14 years (SD 9). In Finland there are over 600 railway maintenance workers who use vibrating tools. The frequency-weighted acceleration of hand-arm vibration was calculated according to the ISO 5349 standard. Hand-held tamping machines had caused most of the vibration exposure, and aw4h was 10.6 m/s2 measured on the handlebar of tamping machine, but many workers also used other vibrating tools. The annual vibration level was 2.5 m/s2 when the use of all vibrating tools and the exposure time was taken into account. In the questionnaire the prevalence of vibration-induced white finger (VWF) was 14% in the entire material, and the prevalence of VWF increased significantly with the total duration of the maintenance work. In addition, 39% of the subjects had suffered numbness of the hands, and the prevalence of hand numbness also increased significantly with the total duration of maintenance work. According to the measurements of vibration and the prevalence of hand symptoms the present investigation indicates vibration syndrome as being related to railway track maintenance work. In the exposure group, where tamping machines mainly were used and exposure to other vibration was small, the prevalence of VWF was also significantly higher, but the prevalence of hand numbness insignificant compared with the control group. In this study vascular and nerve hand symptoms were considered to cause serious trouble in work by 4-11% of the maintenance workers.
Technology in the teaching of neuroscience: enhanced student learning.
Griffin, John D
2003-12-01
The primary motivation for integrating any form of education technology into a particular course or curriculum should always be to enhance student learning. However, it can be difficult to determine which technologies will be the most appropriate and effective teaching tools. Through the alignment of technology-enhanced learning experiences with a clear set of learning objectives, teaching becomes more efficient and effective and learning is truly enhanced. In this article, I describe how I have made extensive use of technology in two neuroscience courses that differ in structure and content. Course websites function as resource centers and provide a forum for student interaction. PowerPoint presentations enhance formal lectures and provide an organized outline of presented material. Some lectures are also supplemented with interactive CD-ROMs, used in the presentation of difficult physiological concepts. In addition, a computer-based physiological recording system is used in laboratory sessions, improving the hands-on experience of group learning while reinforcing the concepts of the research method. Although technology can provide powerful teaching tools, the enhancement of the learning environment is still dependent on the instructor. It is the skill and enthusiasm of the instructor that determines whether technology will be used effectively.
The Robonaut 2 Hand - Designed to do Work with Tools
NASA Technical Reports Server (NTRS)
Bridgwater, L. B.; Ihrke, C. A.; Diftler, M. A.; Abdallah, M. E.; Radford, N. A.; Rogers, J. M.; Yayathi, S.; Askew, R. S.; Linn, D. M.
2011-01-01
The second generation Robonaut hand has many advantages over its predecessor. This mechatronic device is more dexterous and has improved force control and sensing giving it the capability to grasp and actuate a wider range of tools. It can achieve higher peak forces at higher speeds than the original. Developed as part of a partnership between General Motors and NASA, the hand is designed to more closely approximate a human hand. Having a more anthropomorphic design allows the hand to attain a larger set of useful grasps for working with human interfaces. Key to the hand s improved performance is the use of lower friction drive elements and a redistribution of components from the hand to the forearm, permitting more sensing in the fingers and palm where it is most important. The following describes the design, mechanical/electrical integration, and control features of the hand. Lessons learned during the development and initial operations along with planned refinements to make it more effective are presented.
NASA Technical Reports Server (NTRS)
Charles, Steve; Williams, Roy
1989-01-01
Data describing the microsurgeon's hand dynamics was recorded and analyzed in order to provide an accurate model for the telemicrosurgery application of the Bimanual Telemicro-operation Test Bed. The model, in turn, will guide the development of algorithms for the control of robotic systems in bimanual telemicro-operation tasks. Measurements were made at the hand-tool interface and include position, acceleration and force between the tool-finger interface. Position information was captured using an orthogonal pulsed magnetic field positioning system resulting in measurements in all six degrees-of-freedom (DOF). Acceleration data at the hands was obtained using accelerometers positioned in a triaxial arrangement on the back of the hand allowing measurements in all three cartesian-coordinate axes. Force data was obtained by using miniature load cells positioned between the tool and the finger and included those forces experienced perpendicular to the tool shaft and those transferred from the tool-tissue site. Position data will provide a minimum/maximum reference frame for the robotic system's work space or envelope. Acceleration data will define the response times needed by the robotic system in order to emulate and subsequently outperform the human operator's tool movements. The force measurements will aid in designing a force-reflective, force-scaling system as well as defining the range of forces the robotic system will encounter. All analog data was acquired by a 16-channel analog-to-digital conversion system residing in a IBM PC/AT-compatible computer at the Center's laboratory. The same system was also used to analyze and present the data.
Masedunskas, Andrius; Milberg, Oleg; Porat-Shliom, Natalie; Sramkova, Monika; Wigand, Tim; Amornphimoltham, Panomwat; Weigert, Roberto
2012-01-01
Intravital microscopy is an extremely powerful tool that enables imaging several biological processes in live animals. Recently, the ability to image subcellular structures in several organs combined with the development of sophisticated genetic tools has made possible extending this approach to investigate several aspects of cell biology. Here we provide a general overview of intravital microscopy with the goal of highlighting its potential and challenges. Specifically, this review is geared toward researchers that are new to intravital microscopy and focuses on practical aspects of carrying out imaging in live animals. Here we share the know-how that comes from first-hand experience, including topics such as choosing the right imaging platform and modality, surgery and stabilization techniques, anesthesia and temperature control. Moreover, we highlight some of the approaches that facilitate subcellular imaging in live animals by providing numerous examples of imaging selected organelles and the actin cytoskeleton in multiple organs. PMID:22992750
The use of diet in the treatment of epilepsy.
Bailey, Elizabeth E; Pfeifer, Heidi H; Thiele, Elizabeth A
2005-02-01
Fasting and other dietary regimens have been used to treat epilepsy since biblical times. The ketogenic diet, which mimics the metabolism of fasting, was used by modern physicians to treat intractable epilepsy beginning in the 1920s. With the rising popularity of drug treatments however, the ketogenic diet lost its previous status and was used in only a handful of clinics for most of the 20th century. The diet regained widespread recognition as a viable treatment option beginning in 1992 due to the efforts of parent advocate groups. Despite challenges to implementation of the treatment, the ketogenic diet has significant potential as a powerful tool for fighting epilepsy.
Can we influence prescribing patterns?
Sbarbaro, J A
2001-09-15
A variety of programming techniques and methods of training have been employed to change physician behavior. Didactic continuing medical education lectures and clinical guidelines have had minimal impact, although endorsement of national professional guidelines by local opinion leaders appears to have a positive influence on the impact of professional guidelines. Interactive, hands-on workshops, performance reporting, and peer/patient feedback are also effective. Changing prescribing habits has been equally difficult. Drug utilization letters involving both pharmacist and physician have more impact than do letters sent only to the physician. Academic detailing, when properly executed, has been consistently effective. When combined with these strategies, closed formularies become a powerful tool in changing prescribing behavior.
Sung, Peng-Cheng
2014-01-01
This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.
ERIC Educational Resources Information Center
Miles, Barbara
This paper examines the importance of hands for the person who is deafblind, reviews hand development, and identifies specific teaching skills that facilitate hand development and expressiveness in persons who are deafblind. It notes that the hands of a deafblind individual serve not only as tools but also as sense organs (to compensate for their…
Human-scale interaction for virtual model displays: a clear case for real tools
NASA Astrophysics Data System (ADS)
Williams, George C.; McDowall, Ian E.; Bolas, Mark T.
1998-04-01
We describe a hand-held user interface for interacting with virtual environments displayed on a Virtual Model Display. The tool, constructed entirely of transparent materials, is see-through. We render a graphical counterpart of the tool on the display and map it one-to-one with the real tool. This feature, combined with a capability for touch- sensitive, discrete input, results in a useful spatial input device that is visually versatile. We discuss the tool's design and interaction techniques it supports. Briefly, we look at the human factors issues and engineering challenges presented by this tool and, in general, by the class of hand-held user interfaces that are see-through.
The influence of cooling forearm/hand and gender on estimation of handgrip strength.
Cheng, Chih-Chan; Shih, Yuh-Chuan; Tsai, Yue-Jin; Chi, Chia-Fen
2014-01-01
Handgrip strength is essential in manual operations and activities of daily life, but the influence of forearm/hand skin temperature on estimation of handgrip strength is not well documented. Therefore, the present study intended to investigate the effect of local cooling of the forearm/hand on estimation of handgrip strength at various target force levels (TFLs, in percentage of MVC) for both genders. A cold pressor test was used to lower and maintain the hand skin temperature at 14°C for comparison with the uncooled condition. A total of 10 male and 10 female participants were recruited. The results indicated that females had greater absolute estimation deviations. In addition, both genders had greater absolute deviations in the middle range of TFLs. Cooling caused an underestimation of grip strength. Furthermore, a power function is recommended for establishing the relationship between actual and estimated handgrip force. Statement of relevance: Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Practitioner Summary: It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force
Casellato, Claudia; Gandolla, Marta; Crippa, Alessandro; Pedrocchi, Alessandra
2017-07-01
Autism spectrum disorder (ASD) is a multifaceted neurodevelopmental disorder characterized by a persistence of social and communication impairment, and restricted and repetitive behaviors. However, motor disorders have also been described, but not objectively assessed. Most studies showed inefficient eye-hand coordination and motor learning in children with ASD; in other experiments, mechanisms of acquisition of internal models in self-generated movements appeared to be normal in autism. In this framework, we have developed a robotic protocol, recording gaze and hand data during upper limb tasks, in which a haptic pen-like handle is moved along specific trajectories displayed on the screen. The protocol includes trials of reaching under a perturbing force field and catching moving targets, with or without visual availability of the whole path. We acquired 16 typically-developing scholar-age children and one child with ASD as a case study. Speed-accuracy tradeoff, motor performance, and gaze-hand spatial coordination have been evaluated. Compared to typically developing peers, in the force field sequence, the child with ASD showed an intact but delayed learning, and more variable gazehand patterns. In the catching trials, he showed less efficient movements, but an intact capability of exploiting the available a-priori plan. The proposed protocol represents a powerful tool, easily tunable, for quantitative (longitudinal) assessment, and for subject-tailored training in ASD.
Single trial detection of hand poses in human ECoG using CSP based feature extraction.
Kapeller, C; Schneider, C; Kamada, K; Ogawa, H; Kunii, N; Ortner, R; Pruckl, R; Guger, C
2014-01-01
Decoding brain activity of corresponding highlevel tasks may lead to an independent and intuitively controlled Brain-Computer Interface (BCI). Most of today's BCI research focuses on analyzing the electroencephalogram (EEG) which provides only limited spatial and temporal resolution. Derived electrocorticographic (ECoG) signals allow the investigation of spatially highly focused task-related activation within the high-gamma frequency band, making the discrimination of individual finger movements or complex grasping tasks possible. Common spatial patterns (CSP) are commonly used for BCI systems and provide a powerful tool for feature optimization and dimensionality reduction. This work focused on the discrimination of (i) three complex hand movements, as well as (ii) hand movement and idle state. Two subjects S1 and S2 performed single `open', `peace' and `fist' hand poses in multiple trials. Signals in the high-gamma frequency range between 100 and 500 Hz were spatially filtered based on a CSP algorithm for (i) and (ii). Additionally, a manual feature selection approach was tested for (i). A multi-class linear discriminant analysis (LDA) showed for (i) an error rate of 13.89 % / 7.22 % and 18.42 % / 1.17 % for S1 and S2 using manually / CSP selected features, where for (ii) a two class LDA lead to a classification error of 13.39 % and 2.33 % for S1 and S2, respectively.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-803] Heavy Forged Hand Tools (i.e... Administration, International Trade Administration, Department of Commerce. SUMMARY: On January 3, 2011, the Department of Commerce (``Department'') initiated a sunset review of the antidumping duty orders on heavy...
The Use of Hand Tools in Agricultural Mechanics.
ERIC Educational Resources Information Center
Montana State Univ., Bozeman. Dept. of Agricultural and Industrial Education.
This document contains a unit for teaching the use of hand tools in agricultural mechanics in Montana. It consists of an outline of the unit and seven lesson plans. The unit outline contains the following components: situation, aims and goals, list of lessons, student activities, teacher activities, special equipment needed, and references. The…
Judging and Actualizing Intrapersonal and Interpersonal Affordances
ERIC Educational Resources Information Center
Richardson, Michael J.; Marsh, Kerry L.; Baron, Reuben M.
2007-01-01
The current study investigated the perception of intrapersonal, interpersonal, and tool-based grasping possibilities. In Experiment 1, participants judged whether they would grasp planks of wood-presented in ascending, descending, and random orders of length-using one hand (1H), two hands (2H), or with a tool that extended their reach (TH). In…
NASA Astrophysics Data System (ADS)
Hadi, Nik Azran Ab; Rashid, Wan Norhisyam Abd; Hashim, Nik Mohd Zarifie; Mohamad, Najmiah Radiah; Kadmin, Ahmad Fauzan
2017-10-01
Electricity is the most powerful energy source in the world. Engineer and technologist combined and cooperated to invent a new low-cost technology and free carbon emission where the carbon emission issue is a major concern now due to global warming. Renewable energy sources such as hydro, wind and wave are becoming widespread to reduce the carbon emissions, on the other hand, this effort needs several novel methods, techniques and technologies compared to coal-based power. Power quality of renewable sources needs in depth research and endless study to improve renewable energy technologies. The aim of this project is to investigate the impact of renewable electric generator on its local distribution system. The power farm was designed to connect to the local distribution system and it will be investigated and analyzed to make sure that energy which is supplied to customer is clean. The MATLAB tools are used to simulate the overall analysis. At the end of the project, a summary of identifying various voltage fluctuates data sources is presented in terms of voltage flicker. A suggestion of the analysis impact of wave power generation on its local distribution is also presented for the development of wave generator farms.
Handle grip span for optimising finger-specific force capability as a function of hand size.
Lee, Soo-Jin; Kong, Yong-Ku; Lowe, Brian D; Song, Seongho
2009-05-01
Five grip spans (45 to 65 mm) were tested to evaluate the effects of handle grip span and user's hand size on maximum grip strength, individual finger force and subjective ratings of comfort using a computerised digital dynamometer with independent finger force sensors. Forty-six males participated and were assigned into three hand size groups (small, medium, large) according to their hands' length. In general, results showed the 55- and 50-mm grip spans were rated as the most comfortable sizes and showed the largest grip strength (433.6 N and 430.8 N, respectively), whereas the 65-mm grip span handle was rated as the least comfortable size and the least grip strength. With regard to the interaction effect of grip span and hand size, small and medium-hand participants rated the best preference for the 50- to 55-mm grip spans and the least for the 65-mm grip span, whereas large-hand participants rated the 55- to 60-mm grip spans as the most preferred and the 45-mm grip span as the least preferred. Normalised grip span (NGS) ratios (29% and 27%) are the ratios of user's hand length to handle grip span. The NGS ratios were obtained and applied for suggesting handle grip spans in order to maximise subjective comfort as well as gripping force according to the users' hand sizes. In the analysis of individual finger force, the middle finger force showed the highest contribution (37.5%) to the total finger force, followed by the ring (28.7%), index (20.2%) and little (13.6%) finger. In addition, each finger was observed to have a different optimal grip span for exerting the maximum force, resulting in a bow-contoured shaped handle (the grip span of the handle at the centre is larger than the handle at the end) for two-handle hand tools. Thus, the grip spans for two-handle hand tools may be designed according to the users' hand/finger anthropometrics to maximise subjective ratings and performance based on this study. Results obtained in this study will provide guidelines for hand tool designers and manufacturers for designing grip spans of two-handle tools, which can maximise handle comfort and performance.
Tremor and hand-arm vibration syndrome (HAVS) in road maintenance workers.
Bast-Pettersen, Rita; Ulvestad, Bente; Færden, Karl; Clemm, Thomas Aleksander C; Olsen, Raymond; Ellingsen, Dag Gunnar; Nordby, Karl-Christian
2017-01-01
The aim of this study was to evaluate postural and rest tremor among workers using vibrating hand tools, taking into account the possible effects of toxicants such as alcohol and tobacco. A further aim was to study workers diagnosed with hand-arm vibration syndrome (HAVS) at the time of examination. This study comprises 103 road maintenance workers, 55 exposed to vibrating hand tools (age 41.0 years; range 21-62) and 48 referents (age 38.5 years; range 19-64). They were examined with the CATSYS Tremor Pen ® . Exposure to vibrating tools and serum biomarkers of alcohol and tobacco consumption were measured. Cumulative exposure to vibrating tools was associated with increased postural (p < 0.01) and rest tremor (p < 0.05) and with a higher Center Frequency of postural tremor (p < 0.01) among smokers and users of smokeless tobacco. Rest tremor Center Frequency was higher than postural tremor frequency (p < 0.001). The main findings indicate an association between cumulative exposure to hand-held vibrating tools, tremor parameters and consumption of tobacco products. The hand position is important when testing for tremor. Rest tremor had a higher Center Frequency. Postural tremor was more strongly associated with exposure than rest tremor. The finding of increased tremor among the HAVS subjects indicated that tremor might be a part of the clinical picture of a HAVS diagnosis. As with all cross-sectional studies, inferences should be made with caution when drawing conclusions about associations between exposure and possible effects. Future research using longitudinal design is required to validate the findings of the present study.
Vosbikian, Michael M; Harper, Carl M; Byers, Ashlyn; Gutman, Adva; Novack, Victor; Iorio, Matthew L
2017-04-01
Over 50,000 power saw-related injuries occur annually in the United States. Numerous safety measures have been implemented to protect the users of these tools. This study was designed to determine which interventions, if any, have had a positive impact on the safety of the consumer or laborer. We queried the National Electronic Injury Surveillance System database for hand and upper-extremity injuries attributed to power saws from 1997 to 2014. Demographic information including age, sex, date of injury, device, location, body part involved, diagnosis, and disposition was recorded. We performed statistical analysis using interrupted time series analysis to evaluate the incidence of injury with respect to specific safety guidelines as well as temporal trends including patients' age. An 18% increase in power saw-related injuries was noted from 1997 (44,877) to 2005 (75,037). From 2006 to 2015 an annual decrease of 5.8% was observed. This was correlated with regulations for power saw use by the Consumer Safety Product Commission (CPSC) and Underwriters Laboratories. Mean age of injured patients increased from 48.8 to 52.9 years whereas the proportion of subjects aged less than 50 years decreased from 52.8% to 41.9%. These trends were most pronounced after the 2006 CPSC regulations. The incidence of power saw injuries increased from 1997 to 2005, with a subsequent decrease from 2006 to 2015. The guidelines for safer operation and improvements in equipment, mandated by the CPSC and Underwriters Laboratories, appeared to have been successful in precipitating a decrease in the incidence of power saw injuries to the upper extremity, particularly in the younger population. The publication of safety regulations has been noted to have an association with a decreased incidence in power saw injuries. Based on this, clinicians should take an active role in their practice as well as in their professional societies to educate and counsel patients to prevent further injury. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Thermography applied acupuncture and qi-gong
NASA Astrophysics Data System (ADS)
Qin, Yuwen; Ji, Hong-Wei; Chen, Jin-Long; Li, Hong-Qi
1997-04-01
Thermographic technique can be used to measure temperature distribution of body surface in real-time, non-contact and full-field, which has been successfully used in medical diagnosis, remote sensing, and NDT, etc. The authors have developed a thermographic experiment that can be applied to inspect the effect of action of acupuncture and qi-gong (a system of deep breathing exercises) by measuring the temperature of hand and arm. The observation is performed respectively by thermography for the dynamic changes of temperature of the arm and hand after acupuncture therapy and qi-gong therapy. Thermographic results show that the temperature on the collateral channels increases markedly. In the meantime, it can be seen that the above therapies of Chinese medicine can stimulate the channel collateral system. This also contributes a new basis to the effect of action of the therapies of Chinese medicine. The work shows that thermographic technique is a powerful tool for research in Chinese medicine. In this paper, some thermal images are obtained from the persons treated with acupuncture and qi- gong.
NASA Astrophysics Data System (ADS)
Noguera, José M.; Correyero, Beatriz
After the consolidation of weblogs as interactive narratives and producers, audiovisual formats are gaining ground on the Web. Videos are spreading all over the Internet and establishing themselves as a new medium for political propaganda inside social media with tools so powerful like YouTube. This investigation proceeds in two stages: on one hand we are going to examine how this audiovisual formats have enjoyed an enormous amount of attention in blogs during the Spanish pre-electoral campaign for the elections of March 2008. On the other hand, this article tries to investigate the social impact of this phenomenon using data from a content analysis of the blog discussion related to these videos centered on the most popular Spanish political blogs. Also, we study when the audiovisual political messages (made by politicians or by users) "born" and "die" in the Web and with what kind of rules they do.
Problems of Mathematical Finance by Stochastic Control Methods
NASA Astrophysics Data System (ADS)
Stettner, Łukasz
The purpose of this paper is to present main ideas of mathematics of finance using the stochastic control methods. There is an interplay between stochastic control and mathematics of finance. On the one hand stochastic control is a powerful tool to study financial problems. On the other hand financial applications have stimulated development in several research subareas of stochastic control in the last two decades. We start with pricing of financial derivatives and modeling of asset prices, studying the conditions for the absence of arbitrage. Then we consider pricing of defaultable contingent claims. Investments in bonds lead us to the term structure modeling problems. Special attention is devoted to historical static portfolio analysis called Markowitz theory. We also briefly sketch dynamic portfolio problems using viscosity solutions to Hamilton-Jacobi-Bellman equation, martingale-convex analysis method or stochastic maximum principle together with backward stochastic differential equation. Finally, long time portfolio analysis for both risk neutral and risk sensitive functionals is introduced.
A streamlined software environment for situated skills
NASA Technical Reports Server (NTRS)
Yu, Sophia T.; Slack, Marc G.; Miller, David P.
1994-01-01
This paper documents a powerful set of software tools used for developing situated skills. These situated skills form the reactive level of a three-tiered intelligent agent architecture. The architecture is designed to allow these skills to be manipulated by a task level engine which is monitoring the current situation and selecting skills necessary for the current task. The idea is to coordinate the dynamic activations and deactivations of these situated skills in order to configure the reactive layer for the task at hand. The heart of the skills environment is a data flow mechanism which pipelines the currently active skills for execution. A front end graphical interface serves as a debugging facility during skill development and testing. We are able to integrate skills developed in different languages into the skills environment. The power of the skills environment lies in the amount of time it saves for the programmer to develop code for the reactive layer of a robot.
Computational resources for ribosome profiling: from database to Web server and software.
Wang, Hongwei; Wang, Yan; Xie, Zhi
2017-08-14
Ribosome profiling is emerging as a powerful technique that enables genome-wide investigation of in vivo translation at sub-codon resolution. The increasing application of ribosome profiling in recent years has achieved remarkable progress toward understanding the composition, regulation and mechanism of translation. This benefits from not only the awesome power of ribosome profiling but also an extensive range of computational resources available for ribosome profiling. At present, however, a comprehensive review on these resources is still lacking. Here, we survey the recent computational advances guided by ribosome profiling, with a focus on databases, Web servers and software tools for storing, visualizing and analyzing ribosome profiling data. This review is intended to provide experimental and computational biologists with a reference to make appropriate choices among existing resources for the question at hand. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Aghanejad, Iman; Markley, Loïc
2017-11-01
We present spatial frequency maps of power flow in metamaterials and photonic crystals in order to provide insights into their electromagnetic responses and further our understanding of backward power in periodic structures. Since 2001, many different structures across the electromagnetic spectrum have been presented in the literature as exhibiting an isotropic negative effective index. Although these structures all exhibit circular or spherical equifrequency contours that resemble those of left-handed media, here we show through k -space diagrams that the distribution of power in the spatial frequency domain can vary considerably across these structures. In particular, we show that backward power arises from high-order right-handed harmonics in photonic crystals, magnetodielectric crystals, and across the layers of coupled-plasmonic-waveguide metamaterials, while arising from left-handed harmonic pairs in split-ring resonator and wire composites, plasmonic crystals, and along the layers of coupled-plasmonic-waveguide metamaterials. We also show that the fishnet structure exhibits the same left-handed harmonic pairs as the latter group. These observations allow us to categorize different metamaterials according to their spatial spectral source of backward power and identify the mechanism behind negative refraction at a given interface. Finally, we discuss how k -space maps of power flow can be used to explain the high or low transmittance of power into different metamaterial or photonic crystal structures.
Dissecting children's observational learning of complex actions through selective video displays.
Flynn, Emma; Whiten, Andrew
2013-10-01
Children can learn how to use complex objects by watching others, yet the relative importance of different elements they may observe, such as the interactions of the individual parts of the apparatus, a model's movements, and desirable outcomes, remains unclear. In total, 140 3-year-olds and 140 5-year-olds participated in a study where they observed a video showing tools being used to extract a reward item from a complex puzzle box. Conditions varied according to the elements that could be seen in the video: (a) the whole display, including the model's hands, the tools, and the box; (b) the tools and the box but not the model's hands; (c) the model's hands and the tools but not the box; (d) only the end state with the box opened; and (e) no demonstration. Children's later attempts at the task were coded to establish whether they imitated the hierarchically organized sequence of the model's actions, the action details, and/or the outcome. Children's successful retrieval of the reward from the box and the replication of hierarchical sequence information were reduced in all but the whole display condition. Only once children had attempted the task and witnessed a second demonstration did the display focused on the tools and box prove to be better for hierarchical sequence information than the display focused on the tools and hands only. Copyright © 2013 Elsevier Inc. All rights reserved.
[Optimization of end-tool parameters based on robot hand-eye calibration].
Zhang, Lilong; Cao, Tong; Liu, Da
2017-04-01
A new one-time registration method was developed in this research for hand-eye calibration of a surgical robot to simplify the operation process and reduce the preparation time. And a new and practical method is introduced in this research to optimize the end-tool parameters of the surgical robot based on analysis of the error sources in this registration method. In the process with one-time registration method, firstly a marker on the end-tool of the robot was recognized by a fixed binocular camera, and then the orientation and position of the marker were calculated based on the joint parameters of the robot. Secondly the relationship between the camera coordinate system and the robot base coordinate system could be established to complete the hand-eye calibration. Because of manufacturing and assembly errors of robot end-tool, an error equation was established with the transformation matrix between the robot end coordinate system and the robot end-tool coordinate system as the variable. Numerical optimization was employed to optimize end-tool parameters of the robot. The experimental results showed that the one-time registration method could significantly improve the efficiency of the robot hand-eye calibration compared with the existing methods. The parameter optimization method could significantly improve the absolute positioning accuracy of the one-time registration method. The absolute positioning accuracy of the one-time registration method can meet the requirements of the clinical surgery.
NASA Technical Reports Server (NTRS)
Miller, Darcy
2000-01-01
Foreign object debris (FOD) is an important concern while processing space flight hardware. FOD can be defined as "The debris that is left in or around flight hardware, where it could cause damage to that flight hardware," (United Space Alliance, 2000). Just one small screw left unintentionally in the wrong place could delay a launch schedule while it is retrieved, increase the cost of processing, or cause a potentially fatal accident. At this time, there is not a single solution to help reduce the number of dropped parts such as screws, bolts, nuts, and washers during installation. Most of the effort is currently focused on training employees and on capturing the parts once they are dropped. Advances in ergonomics and hand tool design suggest that a solution may be possible, in the form of specialty hand tools, which secure the small parts while they are being handled. To assist in the development of these new advances, a test methodology was developed to conduct a usability evaluation of hand tools, while performing tasks with risk of creating FOD. The methodology also includes hardware in the form of a testing board and the small parts that can be installed onto the board during a test. The usability of new hand tools was determined based on efficiency and the number of dropped parts. To validate the methodology, participants were tested while performing a task that is representative of the type of work that may be done when processing space flight hardware. Test participants installed small parts using their hands and two commercially available tools. The participants were from three groups: (1) students, (2) engineers / managers and (3) technicians. The test was conducted to evaluate the differences in performance when using the three installation methods, as well as the difference in performance of the three participant groups.
Increased Force Variability in Chronic Stroke: Contributions of Force Modulation below 1 Hz
Lodha, Neha; Misra, Gaurav; Coombes, Stephen A.; Christou, Evangelos A.; Cauraugh, James H.
2013-01-01
Increased force variability constitutes a hallmark of arm disabilities following stroke. Force variability is related to the modulation of force below 1 Hz in healthy young and older adults. However, whether the increased force variability observed post stroke is related to the modulation of force below 1 Hz remains unknown. Thus, the purpose of this study was to compare force modulation below 1 Hz in chronic stroke and age-matched healthy individuals. Both stroke and control individuals (N = 26) performed an isometric grip task to submaximal force levels. Coefficient of variation quantified force variability, and power spectrum density of force quantified force modulation below 1 Hz with a high resolution (0.07 Hz). Analyses indicated that force variability was greater for the stroke group compared with to healthy controls and for the paretic hand compared with the non-paretic hand. Force modulation below 1 Hz differentiated the stroke individuals and healthy controls, as well as the paretic and non-paretic hands. Specifically, stroke individuals (paretic hand) exhibited greater power ∼0.2 Hz (0.07–0.35 Hz) and lesser power ∼0.6 Hz (0.49–0.77 Hz) compared to healthy controls (non-dominant hand). Similarly, the paretic hand exhibited greater power ∼0.2 Hz, and lesser power ∼0.6 Hz than the non-paretic hand. Moreover, variability of force was strongly predicted from the modulation of specific frequencies below 1 Hz (R 2 = 0.80). Together, these findings indicate that the modulation of force below 1 Hz provides significant insight into changes in motor control after stroke. PMID:24386208
Hand-rearing and sex determination tool for the Taveta golden weaver (Ploceus castaneiceps).
Breeding, Shawnlei; Ferrie, Gina M; Schutz, Paul; Leighty, Katherine A; Plassé, Chelle
2012-01-01
Improvements in the ability to hand-rear birds in captivity have aided zoological institutions in the sustainable management of these species, and have provided opportunities to examine their physical growth in varying conditions. Monitoring the weight gain and development of chicks is an important aspect of developing a hand-rearing protocol. In this paper we provide the institutional history for a colonial species of passerine, the Taveta golden weaver, at Disney's Animal Kingdom®, in order to demonstrate the methods of establishing a successful breeding program which largely incorporates hand-rearing in management of the population. We also tested if we could accurately predict sex of chicks using weights collected on Day 14 during the hand-rearing process. Using this tool, we were able to correctly determine sex before fledging in more than 83% of chicks. Early sex determination is important in captive species for genetic management and husbandry purposes. While genetic sexing can be expensive, we found that using growth curves to determine sex can be a reliable and cost-effective tool for population management of a colonial passerine. © 2012 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Chambers, Lin H.; Alston, Erica J.; Diones, D. D.; Moore, S. W.; Oots, P. C.; Phelps, C. S.; Mims, Forrest M., III
2006-01-01
On the one hand, locating the right dataset, then figuring out how to use it, is a daunting task that is familiar to almost any scientist or graduate student in the fields of Earth system science. On the other hand, the ability to explore authentic Earth system science data, through inquiry-based education, is an important goal in US national education standards. Fortunately, in the digital age, tools are emerging that can make such data exploration commonplace at all educational levels. This paper describes the conception and development of one project that aims to bridge this gap: Mentoring and inquiry using NASA Data on Atmospheric and Earth science for Teachers and Amateurs (MY NASA DATA; mynasadata.larc.nasa.gov). With funding from NASA's Science Mission Directorate, this project was launched in early 2004 with the aim of developing microsets and identifying other enablers for making data accessible. A key feature of the project is a Live Access Server, the first educational implementation of this open source software, developed by NOAA, that makes it possible to explore multiple data formats through a single interface. This powerful tool is made more useful to the primary target audiences (K-12 and amateur scientists) through careful selection of the data offered, user-friendly explanations of the tool itself, and age-appropriate explanations of the parameters. However experience already shows that graduate students and even practicing scientists can also make use of this resource. The website also hosts teacher-contributed lesson plans, and seeks to feature reports of research projects that use the data.
Engineering of Impulse Mechanism for Mechanical Hander Power Tools
NASA Astrophysics Data System (ADS)
Nikolaevich Drozdov, Anatoliy
2018-03-01
The solution to the problem of human security in cities should be considered on the basis of an integrated and multidisciplinary approach, including issues of security and ecology in the application of technical means used to ensure the viability and development of technocracy. In this regard, an important task is the creation of a safe technique with improved environmental properties with high technological characteristics. This primarily relates to mechanised tool — the division of technological machines with built in engines is that their weight is fully or partially perceived by the operator’s hands, making the flow and control of the car. For this subclass of machines is characterized by certain features: a built-in motor, perception of at least part of their weight by the operator during the work, the implementation of feeding and management at the expense of the muscular power of the operator. Therefore, among the commonly accepted technical and economic characteristics, machines in this case, important ergonomic (ergonomics), regulation of levels which ensures the safety of the operator. To ergonomics include vibration, noise characteristics, mass, and force feeding machine operator. Vibration is a consequence of the dynamism of the system operator machine - processed object (environment) in which the engine energy is redistributed among all the structures, causing their instability. In the machine vibration caused by technological and constructive (transformative mechanisms) unbalance of individual parts of the drive, the presence of technological and design (impact mechanisms) clearances and other reasons. This article describes a new design of impulse mechanism for hander power tools (wrenches, screwdrivers) with enhanced torque. The article substantiates a simulation model of dynamic compression process in an operating chamber during impact, provides simulation results and outlines further lines of research.
Marin-Webb, Victor; Jessen, Heiko; Kopp, Ute; Jessen, Arne B; Hahn, Katrin
2016-01-01
HIV-associated neurocognitive disorders (HAND) are widely present among people living with HIV. Especially its milder forms, asymptomatic neurocognitive impairment (ANI) and mild neurocognitive disorder (MND), remain highly prevalent worldwide. Diagnosing these conditions is subject to a time and resource consuming neuropsychological assessment. Selecting patients at a higher risk of cognitive impairment by using a simple but effective screening tool helps to organise access to further neuropsychological diagnosis. The International HIV Dementia Scale (IHDS) has until now been a well-established screening tool in African and American countries, however these populations' demographics defer significantly from ours, so using the same parameters could be ineffective. To calculate the prevalence of this condition among people attending an HIV outpatient clinic in Berlin and to validate the use of the IHDS as a screening tool for HAND in a German-speaking population. We screened 480 HIV-infected patients using the IHDS, 89% of them were on a stable antiretroviral treatment. Ninety of them completed a standardised neuropsychological battery of tests and a specific cognitive complaints questionnaire. The same procedure was applied to a control group of 30 HIV-negative participants. HAND diagnosis was established according to the Frascati criteria. The overall prevalence of HAND in our cohort was 43% (20% ANI, 17% MND and 6% HIV-associated dementia). The optimal cut-off on the IHDS for detecting HAND cases was set at 11 and achieved both a sensitivity and a specificity of 80%. When specifically screening for the more severe form of HAND, HIV-associated dementia, a cut-off value of 10 offered an increase in both sensitivity (94%) and specificity (86%). The Youden Index for diagnostic accuracy was 0.6 and 0.8, respectively. The prevalence of HAND was comparable to the reported by recent studies performed in countries with a similar economic development. The study confirms the IHDS to be a useful HAND screening tool in primary care settings and establishes new recommendations for its use in German-speaking countries.
Genetic basis in motor skill and hand preference for tool use in chimpanzees (Pan troglodytes).
Hopkins, William D; Reamer, Lisa; Mareno, Mary Catherine; Schapiro, Steven J
2015-02-07
Chimpanzees are well known for their tool using abilities. Numerous studies have documented variability in tool use among chimpanzees and the role that social learning and other factors play in their development. There are also findings on hand use in both captive and wild chimpanzees; however, less understood are the potential roles of genetic and non-genetic mechanisms in determining individual differences in tool use skill and laterality. Here, we examined heritability in tool use skill and handedness for a probing task in a sample of 243 captive chimpanzees. Quantitative genetic analysis, based on the extant pedigrees, showed that overall both tool use skill and handedness were significantly heritable. Significant heritability in motor skill was evident in two genetically distinct populations of apes, and between two cohorts that received different early social rearing experiences. We further found that motor skill decreased with age and that males were more commonly left-handed than females. Collectively, these data suggest that though non-genetic factors do influence tool use performance and handedness in chimpanzees, genetic factors also play a significant role, as has been reported in humans. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Easy-To-Use Connector-Assembly Tool
NASA Technical Reports Server (NTRS)
Redmon, John W., Jr.; Jankowski, Fred
1988-01-01
Tool compensates for user's loss of dexterity under awkward conditions. Has jaws that swivel over 180 degree so angle adjusts with respect to handles. Oriented and held in position most comfortable and effective for user in given situation. Jaws lined with rubber pads so they conform to irregularly shaped parts and grips firmly but gently. Once tool engages part, it locks on it so user can release handles without losing part. Ratchet mechanism in tool allows user to work handles back and forth in confined space to connect or disconnect part. Quickly positioned, locked, and released. Gives user feel of its grip on part. Frees grasping muscles from work during part of task, giving user greater freedom to move hand. Operates with only one hand, leaving user's other hand free to manipulate wiring or other parts. Also adapts to handling and positioning extremely-hot or extremely-cold fluid lines, contaminated objects, abrasive or sharp objects, fragile items, and soft objects.
Reduced Mu Power in Response to Unusual Actions Is Context-Dependent in 1-Year-Olds
Langeloh, Miriam; Buttelmann, David; Matthes, Daniel; Grassmann, Susanne; Pauen, Sabina; Hoehl, Stefanie
2018-01-01
During social interactions infants predict and evaluate other people’s actions. Previous behavioral research found that infants’ imitation of others’ actions depends on these evaluations and is context-dependent: 1-year-olds predominantly imitated an unusual action (turning on a lamp with one’s forehead) when the model’s hands were free compared to when the model’s hands were occupied or restrained. In the present study, we adapted this behavioral paradigm to a neurophysiological study measuring infants’ brain activity while observing usual and unusual actions via electroencephalography. In particular, we measured differences in mu power (6 – 8 Hz) associated with motor activation. In a between-subjects design, 12- to 14-month-old infants watched videos of adult models demonstrating that their hands were either free or restrained. Subsequent test frames showed the models turning on a lamp or a soundbox by using their head or their hand. Results in the hands-free condition revealed that 12- to 14-month-olds displayed a reduction of mu power in frontal regions in response to unusual and thus unexpected actions (head touch) compared to usual and expected actions (hand touch). This may be explained by increased motor activation required for updating prior action predictions in response to unusual actions though alternative explanations in terms of general attention or cognitive control processes may also be considered. In the hands-restrained condition, responses in mu frequency band did not differ between action outcomes. This implies that unusual head-touch actions compared to hand-touch actions do not necessarily evoke a reduction of mu power. Thus, we conclude that reduction of mu frequency power is context-dependent during infants’ action perception. Our results are interpreted in terms of motor system activity measured via changes in mu frequency band as being one important neural mechanism involved in action prediction and evaluation from early on. PMID:29441034
Assessment of the severity of injuries to hands by powered wood splitters.
Lindqvist, Aron; Berglund, Maria; von Kieseritzky, Johanna; Nilsson, Olle
2010-11-01
Our aim was to rate the severity of injuries to hands by powered wood splitters. The patients were identified from a computerised registry, and the cause of injury was confirmed by written questionnaire and structured telephone interview. Information about the anatomy of the injury was gathered from patients' records and radiographs. Severity of injury was rated according to the Hand Injury Severity Scoring System (HISS system) and the Injury Severity Score (ISS). The reliability of HISS rating was tested. The mean Hand Injury Severity Score (HISS) was 63 and the mean ISS was 3.7. Twenty-five (19%) of patients had minor, 41 (31%) had moderate, 30 (23%) had severe, and 35 (27 %) had major injuries when scored by the HISS system. Children's injuries were more severe than those of adults. There was no difference in severity between injuries made by wedge and screw splitters. It is not possible to avoid serious hand injuries from powered wood splitters completely by prohibiting one of the two main types of splitter.
Rubinsten, Orly
2015-01-01
In recent years, cognitive neuroscience research has identified several biological and cognitive features of number processing deficits that may now make it possible to diagnose mental or educational impairments in arithmetic, even earlier and more precisely than is possible using traditional assessment tools. We provide two sets of recommendations for improving cognitive assessment tools, using the important case of mathematics as an example. (1) neurocognitive tests would benefit substantially from incorporating assessments (based on findings from cognitive neuroscience) that entail systematic manipulation of fundamental aspects of number processing. Tests that focus on evaluating networks of core neurocognitive deficits have considerable potential to lead to more precise diagnosis and to provide the basis for designing specific intervention programs tailored to the deficits exhibited by the individual child. (2) implicit knowledge, derived from inspection of variables that are irrelevant to the task at hand, can also provide a useful assessment tool. Implicit knowledge is powerful and plays an important role in human development, especially in cases of psychiatric or neurological deficiencies (such as math learning disabilities or math anxiety).
30 CFR 75.1728 - Power-driven pulleys.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hands except on slow-moving equipment especially designed for hand feeding. (b) Pulleys of conveyors shall not be cleaned manually while the conveyor is in motion. (c) Coal spilled beneath belt conveyor... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1728 Power-driven pulleys. (a) Belts...
Takahashi, Chie; Watt, Simon J.
2014-01-01
When we hold an object while looking at it, estimates from visual and haptic cues to size are combined in a statistically optimal fashion, whereby the “weight” given to each signal reflects their relative reliabilities. This allows object properties to be estimated more precisely than would otherwise be possible. Tools such as pliers and tongs systematically perturb the mapping between object size and the hand opening. This could complicate visual-haptic integration because it may alter the reliability of the haptic signal, thereby disrupting the determination of appropriate signal weights. To investigate this we first measured the reliability of haptic size estimates made with virtual pliers-like tools (created using a stereoscopic display and force-feedback robots) with different “gains” between hand opening and object size. Haptic reliability in tool use was straightforwardly determined by a combination of sensitivity to changes in hand opening and the effects of tool geometry. The precise pattern of sensitivity to hand opening, which violated Weber's law, meant that haptic reliability changed with tool gain. We then examined whether the visuo-motor system accounts for these reliability changes. We measured the weight given to visual and haptic stimuli when both were available, again with different tool gains, by measuring the perceived size of stimuli in which visual and haptic sizes were varied independently. The weight given to each sensory cue changed with tool gain in a manner that closely resembled the predictions of optimal sensory integration. The results are consistent with the idea that different tool geometries are modeled by the brain, allowing it to calculate not only the distal properties of objects felt with tools, but also the certainty with which those properties are known. These findings highlight the flexibility of human sensory integration and tool-use, and potentially provide an approach for optimizing the design of visual-haptic devices. PMID:24592245
The Influence of Wheelchair Propulsion Hand Pattern on Upper Extremity Muscle Power and Stress
Slowik, Jonathan S.; Requejo, Philip S.; Mulroy, Sara J.; Neptune, Richard R.
2016-01-01
The hand pattern (i.e., full-cycle hand path) used during manual wheelchair propulsion is frequently classified as one of four distinct hand pattern types: arc, single loop, double loop and semicircular. Current clinical guidelines recommend the use of the semicircular pattern, which is based on advantageous levels of broad biomechanical metrics implicitly related to the demand placed on the upper extremity (e.g., lower cadence). However, an understanding of the influence of hand pattern on specific measures of upper extremity muscle demand (e.g., muscle power and stress) is needed to help make such recommendations, but these quantities are difficult and impractical to measure experimentally. The purpose of this study was to use musculoskeletal modeling and forward dynamics simulations to investigate the influence of the hand pattern used on specific measures of upper extremity muscle demand. The simulation results suggest that the double loop and semicircular patterns produce the most favorable levels of overall muscle stress and total muscle power. The double loop pattern had the lowest full-cycle and recovery-phase upper extremity demand but required high levels of muscle power during the relatively short contact phase. The semicircular pattern had the second-lowest full-cycle levels of overall muscle stress and total muscle power, and demand was more evenly distributed between the contact and recovery phases. These results suggest that in order to decrease upper extremity demand, manual wheelchair users should use either the double loop or semicircular pattern when propelling their wheelchairs at a self-selected speed on level ground. PMID:27062591
Adeleye, Adedoyin Abiodun; Akanbi, Olusegun Gabriel
2015-01-01
Cutting scissors are important working tools for Nigerian custom tailors (CTs) but its usage apparently does not meet the ergonomics need of these artisans. A survey was carried out amongst CTs using questionnaires to obtain their background social-occupational demographics and observation methods to study their work performance, use of scissors and any cumulative trauma disorder (CTD) in their hands. Thicknesses of various fabrics were measured and comparison between Western world's custom tailoring job and the Nigerian type was done. The results showed some CTD risk factors with finger contusions on the 71 CTs evaluated. The right-hand contusions were traced to the constant usage of unpadded manual scissors with ungloved hands. Disparity between Western and Nigerian tailoring practice may account for the high occurrence of disorders in Nigerian CTs. Since hand dimensions are crucial in the design of hand tools, it is therefore concluded that hand anthropometry of Nigerian CTs and soft padding of manual scissors may mitigate CTD burdens on CTs' hands. Cumulative trauma disorders on the hands of low-income Nigerian CTs needed investigation. This was done via self-assessment and observational methods of the artisans’ work system. Frequent usage of unpadded manual scissors with un-gloved hands cause and exacerbate the problem. Hand anthropometry of users is crucial in scissors manufacturing.
Faivre, Nathan; Dönz, Jonathan; Scandola, Michele; Dhanis, Herberto; Bello Ruiz, Javier; Bernasconi, Fosco; Salomon, Roy; Blanke, Olaf
2017-01-04
Vision is known to be shaped by context, defined by environmental and bodily signals. In the Taylor illusion, the size of an afterimage projected on one's hand changes according to proprioceptive signals conveying hand position. Here, we assessed whether the Taylor illusion does not just depend on the physical hand position, but also on bodily self-consciousness as quantified through illusory hand ownership. Relying on the somatic rubber hand illusion, we manipulated hand ownership, such that participants embodied a rubber hand placed next to their own hand. We found that an afterimage projected on the participant's hand drifted depending on illusory ownership between the participants' two hands, showing an implication of self-representation during the Taylor illusion. Oscillatory power analysis of electroencephalographic signals showed that illusory hand ownership was stronger in participants with stronger α suppression over left sensorimotor cortex, whereas the Taylor illusion correlated with higher β/γ power over frontotemporal regions. Higher γ connectivity between left sensorimotor and inferior parietal cortex was also found during illusory hand ownership. These data show that afterimage drifts in the Taylor illusion do not only depend on the physical hand position but also on subjective ownership, which itself is based on the synchrony of somatosensory signals from the two hands. The effect of ownership on afterimage drifts is associated with β/γ power and γ connectivity between frontoparietal regions and the visual cortex. Together, our results suggest that visual percepts are not only influenced by bodily context but are self-grounded, mapped on a self-referential frame. Vision is influenced by the body: in the Taylor illusion, the size of an afterimage projected on one's hand changes according to tactile and proprioceptive signals conveying hand position. Here, we report a new phenomenon revealing that the perception of afterimages depends not only on bodily signals, but also on the sense of self. Relying on the rubber hand illusion, we manipulated hand ownership, so that participants embodied a rubber hand placed next to their own hand. We found that visual afterimages projected on the participant's hand drifted laterally, only when the rubber hand was embodied. Electroencephalography revealed spectral dissociations between somatic and visual effects, and higher γ connectivity along the dorsal visual pathways when the rubber hand was embodied. Copyright © 2017 the authors 0270-6474/17/370011-12$15.00/0.
Neufuss, Johanna; Humle, Tatyana; Cremaschi, Andrea; Kivell, Tracy L
2017-02-01
There has been an enduring interest in primate tool-use and manipulative abilities, most often with the goal of providing insight into the evolution of human manual dexterity, right-hand preference, and what behaviours make humans unique. Chimpanzees (Pan troglodytes) are arguably the most well-studied tool-users amongst non-human primates, and are particularly well-known for their complex nut-cracking behaviour, which has been documented in several West African populations. However, their sister-taxon, the bonobos (Pan paniscus), rarely engage in even simple tool-use and are not known to nut-crack in the wild. Only a few studies have reported tool-use in captive bonobos, including their ability to crack nuts, but details of this complex tool-use behaviour have not been documented before. Here, we fill this gap with the first comprehensive analysis of bonobo nut-cracking in a natural environment at the Lola ya Bonobo sanctuary, Democratic Republic of the Congo. Eighteen bonobos were studied as they cracked oil palm nuts using stone hammers. Individual bonobos showed exclusive laterality for using the hammerstone and there was a significant group-level right-hand bias. The study revealed 15 hand grips for holding differently sized and weighted hammerstones, 10 of which had not been previously described in the literature. Our findings also demonstrated that bonobos select the most effective hammerstones when nut-cracking. Bonobos are efficient nut-crackers and not that different from the renowned nut-cracking chimpanzees of Bossou, Guinea, which also crack oil palm nuts using stones. © 2016 Wiley Periodicals, Inc.
Removal of simulated biofilm: a preclinical ergonomic comparison of instruments and operators.
Graetz, Christian; Plaumann, Anna; Rauschenbach, Sebastian; Bielfeldt, Jule; Dörfer, Christof E; Schwendicke, Falk
2016-07-01
Periodontal scaling might cause musculoskeletal disorders, and scaling instruments might not only have different effectiveness and efficiency but also differ in their ergonomic properties. The present study assessed ergonomic working patterns of experienced (EO) and less experienced operators (LO) when using hand and powered devices for periodontal scaling and root planning. In an experimental study using periodontally affected manikins, sonic (AIR), ultrasonic (TIG) and hand instruments (GRA) were used by 11 operators (7 EO/4 LO) during simulated supportive periodontal therapy. Using an electronic motion monitoring system, we objectively assessed the working frequency and positioning of hand, neck and head. Operators' subjective evaluation of the instruments was recorded using a questionnaire. Hand instruments were used with the lowest frequency (2.57 ± 1.08 s(-1)) but greatest wrist deviation (59.57 ± 53.94°). EO used instruments more specifically than LO, and generally worked more ergonomically, with less inclination of head and neck in both the frontal and sagittal planes, especially when using hand instruments. All groups found hand instruments more tiring and difficult to use than powered instruments. Regardless of operators' experience, powered instruments were used more ergonomically and were subjectively preferred compared to hand instruments. The use of hand instruments has potential ergonomic disadvantages. However, with increasing experience, operators are able to recognise and mitigate possible risks.
van den Noort, Josien C; Verhagen, Rens; van Dijk, Kees J; Veltink, Peter H; Vos, Michelle C P M; de Bie, Rob M A; Bour, Lo J; Heida, Ciska T
2017-10-01
This proof-of-principle study describes the methodology and explores and demonstrates the applicability of a system, existing of miniature inertial sensors on the hand and a separate force sensor, to objectively quantify hand motor symptoms in patients with Parkinson's disease (PD) in a clinical setting (off- and on-medication condition). Four PD patients were measured in off- and on- dopaminergic medication condition. Finger tapping, rapid hand opening/closing, hand pro/supination, tremor during rest, mental task and kinetic task, and wrist rigidity movements were measured with the system (called the PowerGlove). To demonstrate applicability, various outcome parameters of measured hand motor symptoms of the patients in off- vs. on-medication condition are presented. The methodology described and results presented show applicability of the PowerGlove in a clinical research setting, to objectively quantify hand bradykinesia, tremor and rigidity in PD patients, using a single system. The PowerGlove measured a difference in off- vs. on-medication condition in all tasks in the presented patients with most of its outcome parameters. Further study into the validity and reliability of the outcome parameters is required in a larger cohort of patients, to arrive at an optimal set of parameters that can assist in clinical evaluation and decision-making.
ERIC Educational Resources Information Center
Hawkins, Ian; Phelps, Amy J.
2013-01-01
The use of virtual laboratories has become an increasing issue regarding science laboratories due to the increasing cost of hands-on laboratories, and the increase in distance education. Recent studies have looked at the use of virtual tools for laboratory to be used as supplements to the regular hands-on laboratories but many virtual tools have…
[Sustainable development finds its place in the hospital].
Fraleux, Dorothée
2012-01-01
Driven by the Committee of Sustainable Development in Healthcare, an association founded in 2006, a real momentum of sustainable development in hospitals has been instigated. Drawing on a variety of approaches, sustainable development in hospitals goes hand in hand with modernity and is based on practical tools such as the self-diagnosis tool used as an indicator of sustainable development in healthcare.
Portable concealed weapon detection using millimeter-wave FMCW radar imaging
NASA Astrophysics Data System (ADS)
Johnson, Michael A.; Chang, Yu-Wen
2001-02-01
Unobtrusive detection of concealed weapons on persons or in abandoned bags would provide law enforcement a powerful tool to focus resources and increase traffic throughput in high- risk situations. We have developed a fast image scanning 94 GHz radar system that is suitable for portable operation and remote viewing of radar data. This system includes a novel fast image-scanning antenna that allows for the acquisition of medium resolution 3D millimeter wave images of stationary targets with frame times on order of one second. The 3D radar data allows for potential isolation of concealed weapons from body and environmental clutter such as nearby furniture or other people. The radar is an active system so image quality is not affected indoors, emitted power is however very low so there are no health concerns for operator or targets. The low power operation is still sufficient to penetrate heavy clothing or material. Small system size allows for easy transport and rapid deployment of the system as well as an easy migration path to future hand held systems.
Combination drilling and skiving tool
Stone, William J.
1989-01-01
A combination drilling and skiving tool including a longitudinally extending hollow skiving sleeve slidably and concentrically mounted on a right-handed twist drill. Dogs or pawls provided on the internal periphery of the skiving sleeve engage with the helical grooves of the drill. During a clockwise rotation of the tool, the drill moves downwardly and the sleeve translates upwardly, so that the drill performs a drilling operation on a workpiece. On the other hand, the drill moves upwardly and the sleeve translates downwardly, when the tool is rotated in a counter-clockwise direction, and the sleeve performs a skiving operation. The drilling and skiving operations are separate, independent and exclusive of each other.
Grasp posture alters visual processing biases near the hands
Thomas, Laura E.
2015-01-01
Observers experience biases in visual processing for objects within easy reach of their hands that may assist them in evaluating items that are candidates for action. I investigated the hypothesis that hand postures affording different types of actions differentially bias vision. Across three experiments, participants performed global motion detection and global form perception tasks while their hands were positioned a) near the display in a posture affording a power grasp, b) near the display in a posture affording a precision grasp, or c) in their laps. Although the power grasp posture facilitated performance on the motion task, the precision grasp posture instead facilitated performance on the form task. These results suggest that the visual system weights processing based on an observer’s current affordances for specific actions: fast and forceful power grasps enhance temporal sensitivity, while detail-oriented precision grasps enhance spatial sensitivity. PMID:25862545
Hands-On Universe: A Global Program for Education and Public Outreach in Astronomy
NASA Astrophysics Data System (ADS)
Boër, M.; Thiébaut, C.; Pack, H.; Pennypaker, C.; Isaac, M.; Melchior, A.-L.; Faye, S.; Ebisuzaki, T.
Hands-On Universe (HOU) is an educational program that enables students to investigate the Universe while applying tools and concepts from science, math, and technology. Using the Internet, HOU participants around the world request observations from an automated telescope, download images from a large image archive, and analyze them with the aid of user-friendly image processing software. This program is now in many countries, including the USA, France, Germany, Sweden, Japan, and Australia. A network of telescopes has been established, many of them remotely operated. Students in the classroom are able to make night observations during the day, using a telescope in another country. An archive of images taken on large telescopes is also accessible, as well as resources for teachers. Students deal with real research projects, e.g., the search for asteroids, which resulted in the discovery of a Kuiper Belt object by high-school students. Not only does Hands-On Universe give the general public access to professional astronomy, it also demonstrates the use of a complex automated system, data processing techniques, and automation. Using telescopes located in many countries over the globe, a powerful and genuine cooperation between teachers and children from various countries is promoted, with a clear educational goal.
The Progression of Podcasting/Vodcasting in a Technical Physics Class
NASA Astrophysics Data System (ADS)
Glanville, Y. J.
2010-11-01
Technology such as Microsoft PowerPoint presentations, clickers, podcasting, and learning management suites is becoming prevalent in classrooms. Instructors are using these media in both large lecture hall settings and small classrooms with just a handful of students. Traditionally, each of these media is instructor driven. For instance, podcasting (audio recordings) provided my technical physics course with supplemental notes to accompany a traditional algebra-based physics lecture. Podcasting is an ideal tool for this mode of instruction, but podcasting/vodcasting is also an ideal technique for student projects and student-driven learning. I present here the various podcasting/vodcasting projects my students and I have undertaken over the last few years.
Commerce and genetic diagnostics.
Silverman, Paul H
1995-01-01
The revolution in molecular biology and molecular genetics has begun to reveal the sequence of events that links genes and disease. As a result of activities such as the Human Genome Project, a parallel revolution in technology is bringing nearer to hand the possibility of readily available genetic diagnostics. Genetic testing services have begun to move out of the academic medical centers and into the private enterprise arena. Under these circumstances it is important to understand the factors affecting the availability and application of this powerful predictive tool in a for-profit mode. How does the marketplace encourage or discourage genetic testing? Will the same market influences that generate pharmaceutical sales be operating to "sell" genetic tests?
Editor’s message: Groundwater modeling fantasies - Part 2, down to earth
Voss, Clifford I.
2011-01-01
Simplicity is the final achievement. After one has played a vast quantity of notes and more notes, it is simplicity that emerges as the crowning reward of art. (Frédéric Chopin, a musician and composer, quoted in If Not God, Then What? by Fost 2007)Despite the dubious developments discussed in part 1 of this Editor’s Message (Voss 2011), groundwater modeling really does represent the state of the art in hydrogeology, and groundwater modeling is in fact one of our most powerful tools for enhancing hydrogeologic understanding and for informing management of subsurface resources, at least when in the hands of competent hydrologists.
Motility, Force Generation, and Energy Consumption of Unicellular Parasites.
Hochstetter, Axel; Pfohl, Thomas
2016-07-01
Motility is a key factor for pathogenicity of unicellular parasites, enabling them to infiltrate and evade host cells, and perform several of their life-cycle events. State-of-the-art methods of motility analysis rely on a combination of optical tweezers with high-resolution microscopy and microfluidics. With this technology, propulsion forces, energies, and power generation can be determined so as to shed light on the motion mechanisms, chemotactic behavior, and specific survival strategies of unicellular parasites. With these new tools in hand, we can elucidate the mechanisms of motility and force generation of unicellular parasites, and identify ways to manipulate and eventually inhibit them. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation
NASA Astrophysics Data System (ADS)
Riyadi, Munawar A.; Nugraha, A.; Santoso, M. B.; Septaditya, D.; Prakoso, T.
2017-04-01
Common weight scales cannot assess body composition or determine fat mass and fat-fress mass that make up the body weight. This research propose bio-impedance analysis (BIA) tool capable to body composition assessment. This tool uses four electrodes, two of which are used for 50 kHz sine wave current flow to the body and the rest are used to measure the voltage produced by the body for impedance analysis. Parameters such as height, weight, age, and gender are provided individually. These parameters together with impedance measurements are then in the process to produce a body fat percentage. The experimental result shows impressive repeatability for successive measurements (stdev ≤ 0.25% fat mass). Moreover, result on the hand to hand node scheme reveals average absolute difference of total subjects between two analyzer tools of 0.48% (fat mass) with maximum absolute discrepancy of 1.22% (fat mass). On the other hand, the relative error normalized to Omron’s HBF-306 as comparison tool reveals less than 2% relative error. As a result, the system performance offers good evaluation tool for fat mass in the body.
Tools for language: patterned iconicity in sign language nouns and verbs.
Padden, Carol; Hwang, So-One; Lepic, Ryan; Seegers, Sharon
2015-01-01
When naming certain hand-held, man-made tools, American Sign Language (ASL) signers exhibit either of two iconic strategies: a handling strategy, where the hands show holding or grasping an imagined object in action, or an instrument strategy, where the hands represent the shape or a dimension of the object in a typical action. The same strategies are also observed in the gestures of hearing nonsigners identifying pictures of the same set of tools. In this paper, we compare spontaneously created gestures from hearing nonsigning participants to commonly used lexical signs in ASL. Signers and gesturers were asked to respond to pictures of tools and to video vignettes of actions involving the same tools. Nonsigning gesturers overwhelmingly prefer the handling strategy for both the Picture and Video conditions. Nevertheless, they use more instrument forms when identifying tools in pictures, and more handling forms when identifying actions with tools. We found that ASL signers generally favor the instrument strategy when naming tools, but when describing tools being used by an actor, they are significantly more likely to use more handling forms. The finding that both gesturers and signers are more likely to alternate strategies when the stimuli are pictures or video suggests a common cognitive basis for differentiating objects from actions. Furthermore, the presence of a systematic handling/instrument iconic pattern in a sign language demonstrates that a conventionalized sign language exploits the distinction for grammatical purpose, to distinguish nouns and verbs related to tool use. Copyright © 2014 Cognitive Science Society, Inc.
Kong, Yong-Ku; Kim, Dae-Min
2015-01-01
The design and shape of hand tool handles are critical factors for preventing musculoskeletal disorders (MSDs) caused by the use of hand tools. We explored how these factors are related to total force and individual finger force in males and females with various hand anthropometrics. Using the MFFM system, we assessed four indices of anthropometry, and measured total force and individual finger force on various handle designs and shapes. Both total force and individual finger force were significant according to gender and handle shape. Total grip strength to the handle shape indicated the greatest strength with D shape and the least with A shape. From the regression analysis of hand anthropometric indices, the value of R was respectably high at 0.608-0.696. The current study examined the gender and handle shape factors affecting grip strength based on the force measurements from various handle types, in terms of influence on different hand anthropometric indices.
Studying "The Political" in International Aid to Education: Methodological Considerations
ERIC Educational Resources Information Center
Knutsson, Beniamin; Lindberg, Jonas
2017-01-01
The point of departure of this article is an apparent antinomy. On the one hand, there is the powerful argument in political theory on the emergence and consolidation of a post-political condition. On the other hand, research in international and comparative education demonstrates how conflicts and power asymmetries continue to characterize…
Hand function in workers with hand-arm vibration syndrome.
Cederlund, R; Isacsson, A; Lundborg, G
1999-01-01
Hand-arm vibration syndrome has been specially addressed in the Scandinavian countries in recent years, but the syndrome is still not sufficiently recognized in many countries. The object of this preliminary study was to describe the nature and character of vibration-induced impairment in the hands of exposed workers. Twenty symptomatic male workers (aged 28 to 65 years) subjected to vibration by hand-held tools were interviewed about subjective symptoms and activities of daily living and were assessed with a battery of objective tests for sensibility, dexterity, grip function, and grip strength. The test results were compared with normative data. The majority of patients complained of cold intolerance, numbness, pain, sensory impairment, and difficulties in handling manual tools and in handwriting. The various objective tests showed considerable variation in indications of pathologic outcome, revealing differences in sensitivity to detect impaired hand function. Semmes-Weinstein monofilament testing for perception of light touch-deep pressure sensation, the small-object shape identification test, and moving two-point discrimination testing for functional sensibility provided the most indications of pathologic outcomes. The authors conclude that vibration-exposed patients present considerable impairment in hand function.
iGrab: hand orthosis powered by twisted and coiled polymer muscles
NASA Astrophysics Data System (ADS)
Saharan, Lokesh; de Andrade, Monica Jung; Saleem, Wahaj; Baughman, Ray H.; Tadesse, Yonas
2017-10-01
Several works have been reported in powered hand orthosis in the last ten years for assistive or rehabilitative purposes. However, most of these approaches uses conventional actuators such as servo motors to power orthosis. In this work, we demonstrate the recently reported twisted and coiled polymeric (TCP) muscles to drive a compact, light, inexpensive and wearable upper extremity device, iGrab. A 3D printed orthotic hand module was designed, developed and tested for the performance. The device has six 2-ply muscles of diameter 1.35 mm with a length of 380 mm. We used a single 2-ply muscle for each finger and two 2-ply muscles for the thumb. Pulsed actuation of the muscles at 1.8 A current for 25 s with 7% duty cycle under natural cooling showed full flexion of the fingers within 2 s. Modeling and simulation were performed on the device using standard Euler-Lagrangian equations. Our artificial muscles powered hand orthosis demonstrated the capability of pinching and picking objects of different shapes, weights, and sizes.
Jesensek Papez, B; Palfy, M; Mertik, M; Turk, Z
2009-01-01
This study further evaluated a computer-based infrared thermography (IRT) system, which employs artificial neural networks for the diagnosis of carpal tunnel syndrome (CTS) using a large database of 502 thermal images of the dorsal and palmar side of 132 healthy and 119 pathological hands. It confirmed the hypothesis that the dorsal side of the hand is of greater importance than the palmar side when diagnosing CTS thermographically. Using this method it was possible correctly to classify 72.2% of all hands (healthy and pathological) based on dorsal images and > 80% of hands when only severely affected and healthy hands were considered. Compared with the gold standard electromyographic diagnosis of CTS, IRT cannot be recommended as an adequate diagnostic tool when exact severity level diagnosis is required, however we conclude that IRT could be used as a screening tool for severe cases in populations with high ergonomic risk factors of CTS.
Cantero-Téllez, Raquel; Naughton, Nancy; Algar, Lori; Valdes, Kristin
2018-02-28
Systematic review. Mirror therapy is a treatment used to address hand function following a stroke. Measurement of outcomes using appropriate assessment tools is crucial; however, many assessment options exist. The purpose of this study is to systematically review outcome measures that are used to assess hand function following mirror therapy after stroke and, in addition, to identify the psychometric and descriptive properties of the included measures and through the linking process determine if the outcome measures are representative of the International Classification of Functioning, Disability and Health (ICF). Following a comprehensive literature search, outcome measures used in the included studies were linked to the ICF and analyzed based on descriptive information and psychometric properties. Eleven studies met inclusion criteria and included 24 different assessment tools to measure hand or upper limb function. Most outcome measures used in the selected studies (63%) were rated by the evaluating therapist. Thirteen outcome measures (54%) linked to the ICF body function category and 10 measures (42%) linked to activities and participation. One outcome measure was linked to not defined, and all other ICF categories were not represented. A majority of outcome measures have been assessed for validity, reliability, and responsiveness, but responsiveness was the least investigated psychometric property. Current studies on mirror therapy after stroke are not consistent in the assessment tools used to determine hand function. Understanding of study outcomes requires analysis of the assessment tools. The outcome measures used in the included studies are not representative of personal and environmental factors, but tools linking to body functions and activities and participations provide important information on functional outcome. Integrating a combination of measures that are psychometrically sound and reflective of the ICF should be considered for assessment of hand function after mirror therapy after stroke. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
2014-01-01
Topics covered include: Innovative Software Tools Measure Behavioral Alertness; Miniaturized, Portable Sensors Monitor Metabolic Health; Patient Simulators Train Emergency Caregivers; Solar Refrigerators Store Life-Saving Vaccines; Monitors Enable Medication Management in Patients' Homes; Handheld Diagnostic Device Delivers Quick Medical Readings; Experiments Result in Safer, Spin-Resistant Aircraft; Interfaces Visualize Data for Airline Safety, Efficiency; Data Mining Tools Make Flights Safer, More Efficient; NASA Standards Inform Comfortable Car Seats; Heat Shield Paves the Way for Commercial Space; Air Systems Provide Life Support to Miners; Coatings Preserve Metal, Stone, Tile, and Concrete; Robots Spur Software That Lends a Hand; Cloud-Based Data Sharing Connects Emergency Managers; Catalytic Converters Maintain Air Quality in Mines; NASA-Enhanced Water Bottles Filter Water on the Go; Brainwave Monitoring Software Improves Distracted Minds; Thermal Materials Protect Priceless, Personal Keepsakes; Home Air Purifiers Eradicate Harmful Pathogens; Thermal Materials Drive Professional Apparel Line; Radiant Barriers Save Energy in Buildings; Open Source Initiative Powers Real-Time Data Streams; Shuttle Engine Designs Revolutionize Solar Power; Procedure-Authoring Tool Improves Safety on Oil Rigs; Satellite Data Aid Monitoring of Nation's Forests; Mars Technologies Spawn Durable Wind Turbines; Programs Visualize Earth and Space for Interactive Education; Processor Units Reduce Satellite Construction Costs; Software Accelerates Computing Time for Complex Math; Simulation Tools Prevent Signal Interference on Spacecraft; Software Simplifies the Sharing of Numerical Models; Virtual Machine Language Controls Remote Devices; Micro-Accelerometers Monitor Equipment Health; Reactors Save Energy, Costs for Hydrogen Production; Cameras Monitor Spacecraft Integrity to Prevent Failures; Testing Devices Garner Data on Insulation Performance; Smart Sensors Gather Information for Machine Diagnostics; Oxygen Sensors Monitor Bioreactors and Ensure Health and Safety; Vision Algorithms Catch Defects in Screen Displays; and Deformable Mirrors Capture Exoplanet Data, Reflect Lasers.
Prieur, Jacques; Pika, Simone; Blois-Heulin, Catherine; Barbu, Stéphanie
2018-04-14
Understanding variations of apes' laterality between activities is a central issue when investigating the evolutionary origins of human hemispheric specialization of manual functions and language. We assessed laterality of 39 chimpanzees in a non-communication action similar to termite fishing that we compared with data on five frequent conspecific-directed gestures involving a tool previously exploited in the same subjects. We evaluated, first, population-level manual laterality for tool-use in non-communication actions; second, the influence of sociodemographic factors (age, sex, group, and hierarchy) on manual laterality in both non-communication actions and gestures. No significant right-hand bias at the population level was found for non-communication tool use, contrary to our previous findings for gestures involving a tool. A multifactorial analysis revealed that hierarchy and age particularly modulated manual laterality. Dominants and immatures were more right-handed when using a tool in gestures than in non-communication actions. On the contrary, subordinates, adolescents, young and mature adults as well as males were more right-handed when using a tool in non-communication actions than in gestures. Our findings support the hypothesis that some primate species may have a specific left-hemisphere processing gestures distinct from the cerebral system processing non-communication manual actions and to partly support the tool use hypothesis. Copyright © 2018 Elsevier B.V. All rights reserved.
Radio-frequency powered glow discharge device and method with high voltage interface
Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.
1994-06-28
A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.
Radio-frequency powered glow discharge device and method with high voltage interface
Duckworth, Douglas C.; Marcus, R. Kenneth; Donohue, David L.; Lewis, Trousdale A.
1994-01-01
A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.
Williams-Hatala, Erin Marie; Hatala, Kevin G; Gordon, McKenzie; Key, Alastair; Kasper, Margaret; Kivell, Tracy L
2018-06-01
It is widely agreed that biomechanical stresses imposed by stone tool behaviors influenced the evolution of the human hand. Though archaeological evidence suggests that early hominins participated in a variety of tool behaviors, it is unlikely that all behaviors equally influenced modern human hand anatomy. It is more probable that a behavior's likelihood of exerting a selective pressure was a weighted function of the magnitude of stresses associated with that behavior, the benefits received from it, and the amount of time spent performing it. Based on this premise, we focused on the first part of that equation and evaluated magnitudes of stresses associated with stone tool behaviors thought to have been commonly practiced by early hominins, to determine which placed the greatest loads on the digits. Manual pressure data were gathered from 39 human subjects using a Novel Pliance ® manual pressure system while they participated in multiple Plio-Pleistocene tool behaviors: nut-cracking, marrow acquisition with a hammerstone, flake production with a hammerstone, and handaxe and flake use. Manual pressure distributions varied significantly according to behavior, though there was a tendency for regions of the hand subject to the lowest pressures (e.g., proximal phalanges) to be affected less by behavior type. Hammerstone use during marrow acquisition and flake production consistently placed the greatest loads on the digits collectively, on each digit and on each phalanx. Our results suggest that, based solely on the magnitudes of stresses, hammerstone use during marrow acquisition and flake production are the most likely of the assessed behaviors to have influenced the anatomical and functional evolution of the human hand. Copyright © 2018 Elsevier Ltd. All rights reserved.
Dong, Ren G; Welcome, Daniel E; McDowell, Thomas W; Wu, John Z; Schopper, Aaron W
2006-01-01
The objectives of this study are to derive the frequency weighting from three vibration power absorption (VPA) methods (finger VPA, palm VPA, and total or hand VPA), and to explore whether these energy methods are better than the currently accepted acceleration method. To calculate the VPA weightings, the mechanical impedance of eight subjects exposed to a broadband random vibration spectrum in the z(h)-axis using 18 combinations of hand couplings and applied forces was measured. The VPA weightings were compared with the frequency weighting specified in ISO 5349-1 [2001. Mechanical Vibration--Measurement and Evaluation of Human Exposure to Hand--Transmitted Vibration--Part 1: General Requirements. International Organization for Standardization, Geneva, Switzerland]. This study found that the hand and palm VPA weightings are very similar to the ISO weighting but the finger VPA weighting for the combined grip and push action is much higher than the ISO weighting at frequencies higher than 25 Hz. Therefore, this study predicted that the total power absorption of the entire hand-arm system is likely to be correlated with psychophysical response or subjective sensation. However, if the ISO weighting method cannot yield good predictions of the vibration-induced disorders in the fingers and hand, the hand and palm energy methods are unlikely to yield significantly better predictions. The finger VPA is a vibration measure between unweighted and ISO weighted accelerations. The palm VPA method may have some value for studying the disorders in the wrist-arm system.
Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike
2018-05-01
The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P < .05) when comparing postinjury to baseline measures. At the wrist, carpometacarpal and carpal joint injuries were highly detected with an average difference of 32.6% ( P < .05). Other injuries provided varied results. In the absence of pathology, up to 15% difference between left and right scores can be considered normal with a predominance observed below 10%. A difference of 20% can be indicative of a form of pathology, although pathologies can also be present with lower difference or no apparent changes. A difference of >20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.
Ławniczek-Wałczyk, Anna; Gołofit-Szymczak, Małgorzata; Cyprowski, Marcin; Stobnicka, Agata; Górny, Rafał L
2017-04-01
The aim of this study was to characterize the ways of spreading of the most common bacterial species isolated from workers as well as from the air and raw materials at the workplaces in power plant utilizing biomass sources. To monitor microbial transmission and identify the source of contamination in the working environment, a combination of molecular and biochemical methods was applied. The study was carried out at workplaces in power plant utilizes biomass as a main fuel source. At each of the studied workplaces, bioaerosol particles were collected on sterile Teflon filters using personal conical inhalable samplers (CIS), and biomass samples (straw pellets and briquettes, corn briquettes, sunflower pellets and wood chips) were directly taken from their storage places. Simultaneously with that, the swab samples from the hands of ten workers and their used respiratory masks (of FFP2 class) were also collected after the work shift to evaluate individual workers' microbial contamination. In all collected samples, total bacterial concentrations were assessed and the most common microbial isolates were identified to the species level using both biochemical (API tests) and molecular polymerase chain reaction (PCR), followed by random amplification of polymorphic DNA (RAPD) typing methods. The mean concentrations of culturable bacteria in the air and in biomass samples at the studied workplaces were high, i.e. 1.2 × 10 6 cfu/m 3 and 3.8 × 10 4 cfu/g, respectively. The number of bacteria in the swab and mask samples also reached a high level of 1.4 × 10 4 cfu/ml and 1.9 × 10 3 cfu/cm 2 , respectively. Among the most frequently isolated microorganisms from all types of samples were Gram-positive bacteria of the genus Bacillus and Staphylococcus xylosus. 37 bacterial strains belonging to the genus Bacillus (B. licheniformis 8, B. pumilus 15 and B. subtilis 4) and Staphylococcus (10) were genotyped by the RAPD-PCR method. Based on RAPD-PCR analyses, the genomic similarity among 19 Bacillus strains isolated from biomass, air, protective mask and hand samples as well as 6 S. xylosus strains isolated from air, mask and hand samples exceeded 80%. This study demonstrated that biomass is the primary source of bacteria at power plant workplaces. These results also revealed that biomass-associated bacteria can be easily transferred to workers' hands and mask during their routine activities. To improve health protection at the workplaces, adequate training courses on hand hygiene and how to use and remove respiratory masks correctly for workers should be introduced as a key element of the prevention strategy. From the occupational point of view, the PCR-based methods seem to be an efficient tool for a fast and precise typing of bacterial strains isolated from different sources in the occupational environment. Such methods may help to implement appropriate prophylactic procedures and minimize transmission of infectious agents at workplaces.
Charissou, Camille; Amarantini, David; Baurès, Robin; Berton, Eric; Vigouroux, Laurent
2017-11-01
The mechanisms governing the control of musculoskeletal redundancy remain to be fully understood. The hand is highly redundant, and shows different functional role of extensors according to its configuration for a same functional task of finger flexion. Through intermuscular coherence analysis combined with hand musculoskeletal modelling during maximal isometric hand contractions, our aim was to better understand the neural mechanisms underlying the control of muscle force coordination and agonist-antagonist co-contraction. Thirteen participants performed maximal isometric flexions of the fingers in two configurations: power grip (Power) and finger-pressing on a surface (Press). Hand kinematics and force/moment measurements were used as inputs in a musculoskeletal model of the hand to determine muscular tensions and co-contraction. EMG-EMG coherence analysis was performed between wrist and finger flexors and extensor muscle pairs in alpha, beta and gamma frequency bands. Concomitantly with tailored muscle force coordination and increased co-contraction between Press and Power (mean difference: 48.08%; p < 0.05), our results showed muscle-pair-specific modulation of intermuscular coupling, characterized by pair-specific modulation of EMG-EMG coherence between Power and Press (p < 0.05), and a negative linear association between co-contraction and intermuscular coupling for the ECR/FCR agonist-antagonist muscle pair (r = - 0.65; p < 0.05). This study brings new evidence that pair-specific modulation of EMG-EMG coherence is related to modulation of muscle force coordination during hand contractions. Our results highlight the functional importance of intermuscular coupling as a mechanism contributing to the control of muscle force synergies and agonist-antagonist co-contraction.
White, David B.
1991-01-01
An electrical safety device for use in power tools that is designed to automatically discontinue operation of the power tool upon physical contact of the tool with a concealed conductive material. A step down transformer is used to supply the operating power for a disconnect relay and a reset relay. When physical contact is made between the power tool and the conductive material, an electrical circuit through the disconnect relay is completed and the operation of the power tool is automatically interrupted. Once the contact between the tool and conductive material is broken, the power tool can be quickly and easily reactivated by a reset push button activating the reset relay. A remote reset is provided for convenience and efficiency of operation.
Prosthetic Tool For Holding Small Ferromagnetic Parts
NASA Technical Reports Server (NTRS)
Norton, William E.; Carden, James R.; Belcher, Jewell G., Jr.; Vest, Thomas W.
1995-01-01
Tool attached to prosthetic hand or arm enables user to hold nails, screws, nuts, rivets, and other small ferromagnetic objects on small magnetic tip. Device adjusted to hold nail or screw at proper angle for hammering or for use of screwdriver, respectively. Includes base connector with threaded outer surface and lower male member inserted in standard spring-action, quick-connect/quick-disconnect wrist adapter on prosthetic hand or arm.
Evaluation of hand sensibility: a review.
Novak, C B
2001-01-01
Many assessment devices and measures have been described to evaluate sensibility, with little consensus on the optimal measurement tool. The purpose of this paper is to review the assessment methods and devices used in the evaluation of hand sensibility. Consideration is given to the characteristics of each measurement tool, the information necessary for complete patient evaluation, and the battery of valid and reliable measurements that provide the most complete and accurate patient assessment.
There's Enough Space for Everyone
NASA Technical Reports Server (NTRS)
Schumacher, Daniel M.
2010-01-01
Only a few fortunate people have the opportunity to go into space and experience the wonders of our universe first-hand. But thanks to social media and virtual worlds, many unique opportunities exist for us to learn, explore and experience what s out there from wherever we are. NASA and Marshall Space Flight Center (MSFC) are making this even easier to do. From blogs to Twitter messages, from Facebook pages to Flickr Photo sites, NASA is leveraging social media to share never-before-seen footage and inside information on spaceflight, scientific discoveries and other space activities. Over the last year, Marshall has reached more than half-a-million viewers through its high-profile, real-time blogs. Through its Watching a Launch blog, visitors were invited to take the "virtual" rides of their lives as they received a first-hand account of seeing a powerful shuttle launch - up close and personal. Through the Shuttle Ferry Flight blog, they got to experience the Shuttle Atlantis journey home to Kennedy Space Center as it rode "piggyback" on a modified Boeing 747 airplane. This year, Marshall s Flickr photo galleries have been visited over 700,000 times, Ares rocket videos have been viewed on iTunes, YouTube, TeacherTube and NASA Web sites more than 1.2 million times, and Marshall s Facebook Page has over 2,800 "friends" who regularly follow NASA. Social media tools have been a powerful way to reach and inspire the public, but NASA has also used these tools effectively to promote education and outreach. From events such as the Great Moonbuggy Race to the Student Launch Initiative, Marshall has used social networks to interest, excite and engage students. This presentation shares some of NASA s experiences on what has worked . . . and what hasn't . . . and seeks to spread the message that through social media "there's enough space for everyone."
Workplace screening for hand dermatitis: a pilot study.
Nichol, K; Copes, R; Spielmann, S; Kersey, K; Eriksson, J; Holness, D L
2016-01-01
Health care workers (HCWs) are at increased risk for developing occupational skin disease (OSD) such as dermatitis primarily due to exposure to wet work. Identification of risk factors and workplace screening can help early detection of OSD to avoid the condition becoming chronic. To determine risk factors and clinical findings for hand dermatitis using a workplace screening tool. Employees at a large teaching hospital in Toronto, Canada, were invited to complete a two-part hand dermatitis screening tool. Part 1 inquired about hand hygiene practices and Part 2 comprised a visual assessment of participants' hands by a health professional and classification as (i) normal, (ii) mild dermatitis or (iii) moderate/severe dermatitis. Risk factors were determined using chi-square and Cochran-Armitage analysis on a dichotomous variable, where Yes represented either a mild or moderate/severe disease classification. There were 183 participants out of 643 eligible employees; response rate 28%. Mild or moderate/severe dermatitis was present in 72% of participants. These employees were more likely to work directly with patients, have worked longer in a health care setting, wash hands and change gloves more frequently, wear gloves for more hours per day, have a history of eczema or dermatitis and report a current rash on the hands or rash in the past 12 months. There was a high percentage of HCWs with dermatitis and risk factors for dermatitis. These findings argue for increased attention to prevention and early identification of hand dermatitis and support further testing of the workplace screening tool. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
BuddySuite: Command-Line Toolkits for Manipulating Sequences, Alignments, and Phylogenetic Trees.
Bond, Stephen R; Keat, Karl E; Barreira, Sofia N; Baxevanis, Andreas D
2017-06-01
The ability to manipulate sequence, alignment, and phylogenetic tree files has become an increasingly important skill in the life sciences, whether to generate summary information or to prepare data for further downstream analysis. The command line can be an extremely powerful environment for interacting with these resources, but only if the user has the appropriate general-purpose tools on hand. BuddySuite is a collection of four independent yet interrelated command-line toolkits that facilitate each step in the workflow of sequence discovery, curation, alignment, and phylogenetic reconstruction. Most common sequence, alignment, and tree file formats are automatically detected and parsed, and over 100 tools have been implemented for manipulating these data. The project has been engineered to easily accommodate the addition of new tools, is written in the popular programming language Python, and is hosted on the Python Package Index and GitHub to maximize accessibility. Documentation for each BuddySuite tool, including usage examples, is available at http://tiny.cc/buddysuite_wiki. All software is open source and freely available through http://research.nhgri.nih.gov/software/BuddySuite. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution 2017. This work is written by US Government employees and is in the public domain in the US.
Multisurface fixture permits easy grinding of tool bit angles
NASA Technical Reports Server (NTRS)
Jones, C. R.
1966-01-01
Multisurface fixture with a tool holder permits accurate grinding and finishing of right and left hand single point threading tools. All angles are ground by changing the fixture position to rest at various references angles without removing the tool from the holder.
Evaluation of a hand hygiene campaign in outpatient health care clinics.
Kukanich, Kate Stenske; Kaur, Ramandeep; Freeman, Lisa C; Powell, Douglas A
2013-03-01
To improve hand hygiene in two outpatient health care clinics through the introduction of a gel sanitizer and an informational poster. In this interventional study, health care workers at two outpatient clinics were observed for frequency of hand hygiene (attempts versus opportunities). Gel sanitizer and informational posters were introduced together as an intervention. Direct observation of the frequency of hand hygiene was performed during baseline, intervention, and follow-up. A poststudy survey of health care workers was also distributed and collected. In both clinics, the frequency of hand hygiene was poor at baseline (11% and 21%) but improved significantly after intervention (36% and 54%) and was maintained through the follow-up period (32% and 51%). Throughout the study, postcontact hand hygiene was observed significantly more often than precontact hand hygiene. In both clinics, health care workers reported a preference for soap and water; yet observations showed that when the intervention made gel sanitizer available, sanitizer use predominated. Fifty percent of the surveyed health care workers considered the introduction of gel sanitizer to be an effective motivating tool for improving hand hygiene. Hand hygiene performance by health care workers in outpatient clinics may be improved through promoting the use of gel sanitizer and using informational posters. Compared with surveys, direct observation by trained observers may provide more accurate information about worker preferences for hand hygiene tools.
APT, The Phase I Tool for HST Cycle 12
NASA Astrophysics Data System (ADS)
Blacker, B.; Berch, M.; Curtis, G.; Douglas, R.; Downes, R.; Krueger, A.; O'Dea, C.
2002-12-01
In our continuing effort to streamline our systems and improve service to the science community, the Space Telescope Science Institute (STScI) is developing and releasing, APT - The Astronomer's Proposal Tool as the new interface for Hubble Space Telescope (HST) Phase I and Phase II proposal submissions for HST Cycle 12. The goal of the APT, is to bring state of the art technology, more visual tools and power into the hands of proposers so that they can optimize the scientific return of their HST programs. Proposing for HST and other missions, consists of requesting observing time and/or archival research funding. This step is called Phase I, where the scientific merit of a proposal is considered by a community based peer-review process. Accepted proposals then proceed thru Phase II, where the observations are specified in sufficient detail to enable scheduling on the telescope. In this paper we will present our concept and implementation plans for our Phase I development and submission tool, APT. In addition, we will go behind the scenes and discuss the implications for the Science Policies Division (SPD) and other groups at the STScI caused by a new submission tool and submission output products. The Space Telescope Science Institute (STScI) is operated by the Association of Universities for Research in Astronomy, Inc., for the National Aeronautics and Space Administration.
Action observation network in childhood: a comparative fMRI study with adults.
Biagi, Laura; Cioni, Giovanni; Fogassi, Leonardo; Guzzetta, Andrea; Sgandurra, Giuseppina; Tosetti, Michela
2016-11-01
Very little is known about the action observation network and the mirror neuron system (AON/MNS) in children and its age-related properties compared with those observed in adults. In the present fMRI study we explored the activation of areas belonging to the AON/MNS in children and adults during observation of complex hand-grasping actions, as compared to observation of simple grasping acts executed with the left and the right hand, seen from a first person perspective. The results indicate that during the action observation tasks in children there was activation of a cortical network similar to that found in adults, including the premotor cortex, the posterior part of the inferior frontal gyrus and the posterior parietal lobe. However, the activation in children was more widespread and showed a higher inter-subject variability compared with adults. Furthermore, the activated network seems more lateralized to the left hemisphere in adults and more bilateral in children, with a linear growth of lateralization index as a function of age. Finally, in children the activation in the anterior intraparietal cortex (AIP) of each hemisphere was higher during observation of the contralateral hand (hand identity effect) and during the observation of complex actions relative to simple grasping acts, confirming the role of AIP for action-related hand identity previously described in adults. These results support the assumption that structure and size of action representations are sensitive to mechanisms of development and show physiological plasticity. These properties of the AON/MNS could constitute a powerful tool for spontaneous reorganization and recovery of motor deficits after brain injury in children and in adults, as well as for specific rehabilitation programmes. © 2015 John Wiley & Sons Ltd.
Martí-Margarit, Anna; Manresa, Josep M; Herdman, Mike; Pujol, Ramon; Serra, Consol; Flyvholm, Mary-Ann; Giménez-Arnau, Ana M
2015-04-01
Hand eczema is an impacting cutaneous disease. Globally valid tools that help to diagnose hand and forearm eczema are required. To validate the questions to detect hand and/or forearm eczema included in the "Nordic Occupational Skin Questionnaire" (NOSQ-2002) in the Spanish language. A prospective pilot study was conducted with 80 employees of a cleaning company and a retrospective one involving 2,546 individuals. The responses were analysed for sensitivity, specificity and positive and negative predictive values. The final diagnosis according to the patients' hospital records, the specialty care records and the physical examination was taken as gold standard. The Dermatology Life Quality Index (DLQI) was also evaluated. Sensitivity and specificity, in a worst case scenario (WC) combining both questions, were 96.5% and 66.7%, respectively, and in a per protocol (PP) analysis, were 96.5% and 75.2%. The questions validated detected eczema effectively, making this tool suitable for use e.g. in multicentre epidemiological studies or clinical trials.
Trends in fluorescence imaging and related techniques to unravel biological information.
Haustein, Elke; Schwille, Petra
2007-09-01
Optical microscopy is among the most powerful tools that the physical sciences have ever provided biology. It is indispensable for basic lab work, as well as for cutting edge research, as the visual monitoring of life processes still belongs to the most compelling evidences for a multitude of biomedical applications. Along with the rapid development of new probes and methods for the analysis of laser induced fluorescence, optical microscopy over past years experienced a vast increase of both new techniques and novel combinations of established methods to study biological processes with unprecedented spatial and temporal precision. On the one hand, major technical advances have significantly improved spatial resolution. On the other hand, life scientists are moving toward three- and even four-dimensional cell biology and biophysics involving time as a crucial coordinate to quantitatively understand living specimen. Monitoring the whole cell or tissue in real time, rather than producing snap-shot-like two-dimensional projections, will enable more physiological and, thus, more clinically relevant experiments, whereas an increase in temporal resolution facilitates monitoring fast nonperiodic processes as well as the quantitative analysis of characteristic dynamics.
Trends in fluorescence imaging and related techniques to unravel biological information
Haustein, Elke; Schwille, Petra
2007-01-01
Optical microscopy is among the most powerful tools that the physical sciences have ever provided biology. It is indispensable for basic lab work, as well as for cutting edge research, as the visual monitoring of life processes still belongs to the most compelling evidences for a multitude of biomedical applications. Along with the rapid development of new probes and methods for the analysis of laser induced fluorescence, optical microscopy over past years experienced a vast increase of both new techniques and novel combinations of established methods to study biological processes with unprecedented spatial and temporal precision. On the one hand, major technical advances have significantly improved spatial resolution. On the other hand, life scientists are moving toward three- and even four-dimensional cell biology and biophysics involving time as a crucial coordinate to quantitatively understand living specimen. Monitoring the whole cell or tissue in real time, rather than producing snap-shot-like two-dimensional projections, will enable more physiological and, thus, more clinically relevant experiments, whereas an increase in temporal resolution facilitates monitoring fast nonperiodic processes as well as the quantitative analysis of characteristic dynamics. PMID:19404444
Sensitivity of charge transport measurements to local inhomogeneities
NASA Astrophysics Data System (ADS)
Koon, Daniel; Wang, Fei; Hjorth Petersen, Dirch; Hansen, Ole
2012-02-01
We derive analytic expressions for the sensitivity of resistive and Hall measurements to local variations in a specimen's material properties in the combined linear limit of both small magnetic fields and small perturbations, presenting exact, algebraic expressions both for four-point probe measurements on an infinite plane and for symmetric, circular van der Pauw discs. We then generalize the results to obtain corrections to the sensitivities both for finite magnetic fields and for finite perturbations. Calculated functions match published results and computer simulations, and provide an intuitive, visual explanation for experimental misassignment of carrier type in n-type ZnO and agree with published experimental results for holes in a uniform material. These results simplify calculation and plotting of the sensitivities on an NxN grid from a problem of order N^5 to one of order N^3 in the arbitrary case and of order N^2 in the handful of cases that can be solved exactly, putting a powerful tool for inhomogeneity analysis in the hands of the researcher: calculation of the sensitivities requires little more than the solution of Laplace's equation on the specimen geometry.
Visuo-Haptic Mixed Reality with Unobstructed Tool-Hand Integration.
Cosco, Francesco; Garre, Carlos; Bruno, Fabio; Muzzupappa, Maurizio; Otaduy, Miguel A
2013-01-01
Visuo-haptic mixed reality consists of adding to a real scene the ability to see and touch virtual objects. It requires the use of see-through display technology for visually mixing real and virtual objects, and haptic devices for adding haptic interaction with the virtual objects. Unfortunately, the use of commodity haptic devices poses obstruction and misalignment issues that complicate the correct integration of a virtual tool and the user's real hand in the mixed reality scene. In this work, we propose a novel mixed reality paradigm where it is possible to touch and see virtual objects in combination with a real scene, using commodity haptic devices, and with a visually consistent integration of the user's hand and the virtual tool. We discuss the visual obstruction and misalignment issues introduced by commodity haptic devices, and then propose a solution that relies on four simple technical steps: color-based segmentation of the hand, tracking-based segmentation of the haptic device, background repainting using image-based models, and misalignment-free compositing of the user's hand. We have developed a successful proof-of-concept implementation, where a user can touch virtual objects and interact with them in the context of a real scene, and we have evaluated the impact on user performance of obstruction and misalignment correction.
Implicit and Explicit Representations of Hand Position in Tool Use
Rand, Miya K.; Heuer, Herbert
2013-01-01
Understanding the interactions of visual and proprioceptive information in tool use is important as it is the basis for learning of the tool's kinematic transformation and thus skilled performance. This study investigated how the CNS combines seen cursor positions and felt hand positions under a visuo-motor rotation paradigm. Young and older adult participants performed aiming movements on a digitizer while looking at rotated visual feedback on a monitor. After each movement, they judged either the proprioceptively sensed hand direction or the visually sensed cursor direction. We identified asymmetric mutual biases with a strong visual dominance. Furthermore, we found a number of differences between explicit and implicit judgments of hand directions. The explicit judgments had considerably larger variability than the implicit judgments. The bias toward the cursor direction for the explicit judgments was about twice as strong as for the implicit judgments. The individual biases of explicit and implicit judgments were uncorrelated. Biases of these judgments exhibited opposite sequential effects. Moreover, age-related changes were also different between these judgments. The judgment variability was decreased and the bias toward the cursor direction was increased with increasing age only for the explicit judgments. These results indicate distinct explicit and implicit neural representations of hand direction, similar to the notion of distinct visual systems. PMID:23894307
Gentilucci, Maurizio; Campione, Giovanna Cristina; Dalla Volta, Riccardo; Bernardis, Paolo
2009-12-01
Does the mirror system affect the control of speech? This issue was addressed in behavioral and Transcranial Magnetic Stimulation (TMS) experiments. In behavioral experiment 1, participants pronounced the syllable /da/ while observing (1) a hand grasping large and small objects with power and precision grasps, respectively, (2) a foot interacting with large and small objects and (3) differently sized objects presented alone. Voice formant 1 was higher when observing power as compared to precision grasp, whereas it remained unaffected by observation of the different types of foot interaction and objects alone. In TMS experiment 2, we stimulated hand motor cortex, while participants observed the two types of grasp. Motor Evoked Potentials (MEPs) of hand muscles active during the two types of grasp were greater when observing power than precision grasp. In experiments 3-5, TMS was applied to tongue motor cortex of participants silently pronouncing the syllable /da/ and simultaneously observing power and precision grasps, pantomimes of the two types of grasps, and differently sized objects presented alone. Tongue MEPs were greater when observing power than precision grasp either executed or pantomimed. Finally, in TMS experiment 6, the observation of foot interaction with large and small objects did not modulate tongue MEPs. We hypothesized that grasp observation activated motor commands to the mouth as well as to the hand that were congruent with the hand kinematics implemented in the observed type of grasp. The commands to the mouth selectively affected postures of phonation organs and consequently basic features of phonological units.
Ioannou, Christopher; Knight, Matthew; Daniele, Luca; Flueckiger, Lee; Tan, Ezekiel S L
2016-10-17
The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. Torque for both hand and power screw insertion was measured through a load cell, registering 6.66 points per second. This was performed in a controlled environment using synthetic bone, a locking plate and locking screws to simulate plate fixation. Screws were inserted by hand and by drill with torque values measured. The surgical torque limiter (1.5 Nm) was effective as the highest recorded reading in the study was 1.409 Nm. Comparatively, there is a statistically significant difference between screw insertion methods. Torque produced for manually driven screw insertion into locking plates was 1.289 Nm (95 % CI 1.269-1.308) with drill-powered screw insertion at 0.740 Nm (95 % CI 0.723-0.757). The surgical torque limiter proved to be effective as per product specifications. Screws inserted under power produce significantly less torque when compared to manual insertion by hand. This is likely related to the mechanism of the torque limiter when being used at higher speeds for which it was designed. We conclude that screws may be inserted using power to the plate with the addition of a torque limiter. It is recommended that all screws inserted by drill be hand tightened to achieve adequate torque values.
Mugisa, Dana J; Katimbo, Abia; Sempiira, John E; Kisaalita, William S
2016-05-01
Sub-Saharan African women on small-acreage farms carry a disproportionately higher labor burden, which is one of the main reasons they are unable to produce for both home and the market and realize higher incomes. Labor-saving interventions such as hand-tools are needed to save time and/or increase productivity in, for example, land preparation for crop and animal agriculture, post-harvest processing, and meeting daily energy and water needs. Development of such tools requires comprehensive and content-specific anthropometric data or body dimensions and existing databases based on Western women may be less relevant. We conducted measurements on 89 women to provide preliminary results toward answering two questions. First, how well existing databases are applicable in the design of hand-tools for sub-Saharan African women. Second, how universal body dimension predictive models are among ethnic groups. Our results show that, body dimensions between Bantu and Nilotic ethnolinguistic groups are different and both are different from American women. These results strongly support the need for establishing anthropometric databases for sub-Saharan African women, toward hand-tool design. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Investigation of Flash Fill{reg_sign} as a thermal backfill material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayers, P.H.; Charlton, C.B.; Frishette, C.W.
1995-09-01
Flash Fill{reg_sign} was created as a fast-setting, flowable backfill material made entirely from coal combustion by-products and water. Its quick-setting, self-leveling, self-compacting characteristics makes trench road repairs faster, easier, and more economical. Other uses include building foundations, fill around pipes, gas lines, and manholes, and replacement of weak subgrade beneath rooters. Flash Fill can be hand-excavated without the use of power assisted tools or machinery. To enhance thermal resistivity, the original Flash Fill mix was modified to include concrete sand. This resulted in a new Flash Fill, designated FSAND, with all of the aforementioned desirable characteristics of Flash Fill andmore » a thermal resistivity of approximately 50{degree} C-cm/watt. Thermal resistivity tests using conventional laboratory thermal probes, high-current thermal tests, and moisture migration tests have been performed to determine the properties of FSAND. As a result of these tests, FSAND has been approved for use as power cable thermal backfill on all AEP System distribution projects.« less
Analysis of log-periodic power law singularity patterns in time series related to credit risk
NASA Astrophysics Data System (ADS)
Wosnitza, Jan Henrik; Sornette, Didier
2015-04-01
The log-periodic (super-exponential) power law singularity (LPPLS) has become a promising tool for predicting extreme behavior of self-organizing systems in natural sciences and finance. Some researchers have recently proposed to employ the LPPLS on credit risk markets. The review article at hand summarizes four papers in this field and shows how they are linked. After structuring the research questions, we collect the corresponding answers from the four articles. This eventually gives us an overall picture of the application of the LPPLS to credit risk data. Our literature review begins with grounding the view that credit default swap (CDS) spreads are hotbeds for LPPLS patterns and it ends up with drawing attention to the recently proposed alarm index for the prediction of institutional bank runs. By presenting a new field of application for the LPPLS, the reviewed strand of literature further substantiates the LPPLS hypothesis. Moreover, the results suggest that CDS spread trajectories belong to a different universality class than, for instance, stock prices.
The VRFurnace: A Virtual Reality Application for Energy System Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Peter Eric
2001-01-01
The VRFurnace is a unique VR application designed to analyze a complete coal-combustion CFD model of a power plant furnace. Although other applications have been created that analyze furnace performance, no other has included the added complications of particle tracking and the reactions associated with coal combustion. Currently the VRFurnace is a versatile analysis tool. Data translators have been written to allow data from most of the major commercial CFD software packages as well as standard data formats of hand-written code to be uploaded into the VR application. Because of this almost any type of CFD model of any powermore » plant component can be analyzed immediately. The ease of use of the VRFurnace is another of its qualities. The menu system created for the application not only guides first time users through the various button combinations but it also helps the experienced user keep track of which tool is being used. Because the VRFurnace was designed for use in the C6 device at Iowa State University's Virtual Reality Applications Center it is naturally a collaborative project. The projection-based system allows many people to be involved in the analysis process. This type of environment opens the design process to not only include CFD analysts but management teams and plant operators as well by making it easier for engineers to explain design changes. The 3D visualization allows power plant components to be studied in the context of their natural physical environments giving engineers a chance to use their innate pattern recognition and intuitive skills to bring to light key relationships that may have previously gone unrecognized. More specifically, the tools that have been developed make better use of the third dimension that the synthetic environment provides. Whereas the plane tools make it easier to track down interesting features of a given flow field, the box tools allow the user to focus on these features and reduce the data load on the computer.« less
Shape Memory Polymers: A Joint Chemical and Materials Engineering Hands-On Experience
ERIC Educational Resources Information Center
Seif, Mujan; Beck, Matthew
2018-01-01
Hands-on experiences are excellent tools for increasing retention of first year engineering students. They also encourage interdisciplinary collaboration, a critical skill for modern engineers. In this paper, we describe and evaluate a joint Chemical and Materials Engineering hands-on lab that explores cross-linking and glass transition in…
Production rates for crews using hand tools on firelines
Lisa Haven; T. Parkin Hunter; Theodore G. Storey
1982-01-01
Reported rates at which hand crews construct firelines can vary widely because of differences in fuels, fire and measurement conditions, and fuel resistance-to-control classification schemes. Real-time fire dispatching and fire simulation planning models, however, require accurate estimates of hand crew productivity. Errors in estimating rate of fireline production...
29 CFR 780.312 - “Hand harvest laborer” defined.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Employees who hand pick small undesirable fruit prior to harvesting in order to insure a better crop would..., such as a “blueberry picking tool.” “Hand-harvesting” refers only to soil-grown crops and does not... almost simultaneously with the picking and before transportation to the concentration point on the farm...
29 CFR 780.312 - “Hand harvest laborer” defined.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Employees who hand pick small undesirable fruit prior to harvesting in order to insure a better crop would..., such as a “blueberry picking tool.” “Hand-harvesting” refers only to soil-grown crops and does not... almost simultaneously with the picking and before transportation to the concentration point on the farm...
Relationship between Systems-Level Factors and Hand Hygiene Adherence
Dunn-Navarra, Ann-Margaret; Cohen, Bevin; Stone, Patricia W.; Pogorzelska, Monika; Jordan, Sarah; Larson, Elaine
2010-01-01
This study was a cross sectional descriptive survey of acute care hospitals in California to describe staff hand hygiene compliance and related predictors, and explore the relationship between hand hygiene adherence to health care-associated infections. Although there was a relatively small sample size, institutions with morning huddles reported a significantly higher proportion of ≥95% hand hygiene compliance. Huddles are an organizational tool to improve teamwork and communication and may offer promise to influence hand hygiene adherence. PMID:20489659
Behavioral and functional strategies during tool use tasks in bonobos.
Bardo, Ameline; Borel, Antony; Meunier, Hélène; Guéry, Jean-Pascal; Pouydebat, Emmanuelle
2016-09-01
Different primate species have developed extensive capacities for grasping and manipulating objects. However, the manual abilities of primates remain poorly known from a dynamic point of view. The aim of the present study was to quantify the functional and behavioral strategies used by captive bonobos (Pan paniscus) during tool use tasks. The study was conducted on eight captive bonobos which we observed during two tool use tasks: food extraction from a large piece of wood and food recovery from a maze. We focused on grasping postures, in-hand movements, the sequences of grasp postures used that have not been studied in bonobos, and the kind of tools selected. Bonobos used a great variety of grasping postures during both tool use tasks. They were capable of in-hand movement, demonstrated complex sequences of contacts, and showed more dynamic manipulation during the maze task than during the extraction task. They arrived on the location of the task with the tool already modified and used different kinds of tools according to the task. We also observed individual manual strategies. Bonobos were thus able to develop in-hand movements similar to humans and chimpanzees, demonstrated dynamic manipulation, and they responded to task constraints by selecting and modifying tools appropriately, usually before they started the tasks. These results show the necessity to quantify object manipulation in different species to better understand their real manual specificities, which is essential to reconstruct the evolution of primate manual abilities. © 2016 Wiley Periodicals, Inc.
Magnet-wire wrapping tool for integrated circuits
NASA Technical Reports Server (NTRS)
Takahashi, T. H.
1972-01-01
Wire-dispensing tool which resembles mechanical pencil is used to wrap magnet wire around integrated circuit terminals uniformly and securely without damaging insulative coating on wire. Tool is hand-held and easily manipulated to execute wire wrapping movements.
Flex Sensor Based Biofeedback Monitoring for Post-Stroke Fingers Myopathy Patients
NASA Astrophysics Data System (ADS)
Garda, Y. R.; Caesarendra, W.; Tjahjowidodo, T.; Turnip, A.; Wahyudati, S.; Nurhasanah, L.; Sutopo, D.
2018-04-01
Hands are one of the crucial parts of the human body in carrying out daily activities. Accidents on the hands decreasing in motor skills of the hand so that therapy is necessary to restore motor function of the hand. In addition to accidents, hand disabilities can be caused by certain diseases, e.g. stroke. Stroke is a partial destruction of the brain. It occurs if the arteries that drain blood to the brain are blocked, or if torn or leak. The purpose of this study to make biofeedback monitoring equipment for post-stroke hands myopathy patients. Biofeedback is an alternative method of treatment that involves measuring body functions measured subjects such as skin temperature, sweat activity, blood pressure, heart rate and hand paralysis due to stroke. In this study, the sensor used for biofeedback monitoring tool is flex sensor. Flex sensor is a passive resistive device that changes its resistance as the sensor is bent. Flex sensor converts the magnitude of the bend into electrical resistance, the greater the bend the greater the resistance value. The monitoring used in this biofeedback monitoring tool uses Graphical User Interface (GUI) in C# programming language. The motivation of the study is to monitor and record the progressive improvement of the hand therapy. Patients who experienced post-stroke can see the therapy progress quantitatively.
The Exact Art and Subtle Science of DC Smelting: Practical Perspectives on the Hot Zone
NASA Astrophysics Data System (ADS)
Geldenhuys, Isabel J.
2017-02-01
Increasingly, sustainable smelting requires technology that can process metallurgically complex, low-grade, ultra-fine and waste materials. It is likely that more applications for direct current (DC) technology will inevitably follow in the future as DC open-arc furnaces have some wonderful features that facilitate processing of a variety of materials in an open-arc open-bath configuration. A DC open-arc furnace allows for optimization and choice of chemistry to benefit the process, rather than being constrained by the electrical or physical properties of the material. In a DC configuration, the power is typically supplied by an open arc, providing relative independence and thus an extra degree of freedom. However, if the inherent features of the technology are misunderstood, much of the potential may never be realised. It is thus important to take cognisance of the freedom an operator will have as a result of the open arc and ensure that operating strategies are implemented. This extra degree of freedom hands an operator a very flexible tool, namely virtually unlimited power. Successful open-arc smelting is about properly managing the balance between power and feed, and practical perspectives on the importance of power and feed balance are presented to highlight this aspect as the foundation of proper open-arc furnace control.
Hermsdörfer, Joachim; Li, Yong; Randerath, Jennifer; Goldenberg, Georg; Johannsen, Leif
2012-04-01
Movement goals and task mechanics differ substantially between actual tool use and corresponding pantomimes. In addition, apraxia seems to be more severe during pantomime than during actual tool use. Comparisons of these two modes of action execution using quantitative methods of movement analyses are rare. In the present study, repetitive scooping movements with a ladle from a bowl into a plate were recorded and movement kinematics was analyzed. Brain-damaged patients using their ipsilesional hand and healthy control subjects were tested in three conditions: pantomime, demonstration with the tool only, and actual use in the normal context. Analysis of the hand trajectories during the transport component revealed clear differences between the tasks, such as slower actual use and moderate deficits in patients with left brain damage (LBD). LBD patients were particularly impaired in the scooping component: LBD patients with apraxia exhibited reduced hand rotation at the bowl and the plate. The deficit was most obvious during pantomime but actual use was also affected, and reduced hand rotation was consistent across conditions as indicated by strong pair-wise correlations between task conditions. In healthy control subjects, correlations between movement parameters were most evident between the pantomime and demonstration conditions but weak in correlation pairs involving actual use. From these findings and published neuroimaging evidence, we conclude that for a specific tool-use action, common motor schemas are activated but are adjusted and modified according to the actual task constraints and demands. An apraxic LBD individual can show a deficit across all three action conditions, but the severity can differ substantially between conditions.
Education and Outreach with the Virtual Astronomical Observatory
NASA Astrophysics Data System (ADS)
Lawton, Brandon L.; Eisenhamer, B.; Raddick, M. J.; Mattson, B. J.; Harris, J.
2012-01-01
The Virtual Observatory (VO) is an international effort to bring a large-scale electronic integration of astronomy data, tools, and services to the global community. The Virtual Astronomical Observatory (VAO) is the U.S. NSF- and NASA-funded VO effort that seeks to put efficient astronomical tools in the hands of U.S. astronomers, students, educators, and public outreach leaders. These tools will make use of data collected by the multitude of ground- and space-based missions over the previous decades. Many future missions will also be incorporated into the VAO tools when they launch. The Education and Public Outreach (E/PO) program for the VAO is led by the Space Telescope Science Institute in collaboration with the HEASARC E/PO program and Johns Hopkins University. VAO E/PO efforts seek to bring technology, real-world astronomical data, and the story of the development and infrastructure of the VAO to the general public, formal education, and informal education communities. Our E/PO efforts will be structured to provide uniform access to VAO information, enabling educational opportunities across multiple wavelengths and time-series data sets. The VAO team recognizes that many VO programs have built powerful tools for E/PO purposes, such as Microsoft's World Wide Telescope, SDSS Sky Server, Aladin, and a multitude of citizen-science tools available from Zooniverse. We are building partnerships with Microsoft, Zooniverse, and NASA's Night Sky Network to leverage the communities and tools that already exist to meet the needs of our audiences. Our formal education program is standards-based and aims to give teachers the tools to use real astronomical data to teach the STEM subjects. To determine which tools the VAO will incorporate into the formal education program, needs assessments will be conducted with educators across the U.S.
Chang, Yun-Chorng; Lu, Sih-Chen; Chung, Hsin-Chan; Wang, Shih-Ming; Tsai, Tzung-Da; Guo, Tzung-Fang
2013-01-01
Various infra-red and planar chiral metamaterials were fabricated using the modified Nanospherical-Lens Lithography. By replacing the light source with a hand-held ultraviolet lamp, its asymmetric light emission pattern produces the elliptical-shaped photoresist holes after passing through the spheres. The long axis of the ellipse is parallel to the lamp direction. The fabricated ellipse arrays exhibit localized surface plasmon resonance in mid-infra-red and are ideal platforms for surface enhanced infra-red absorption (SEIRA). We also demonstrate a way to design and fabricate complicated patterns by tuning parameters in each exposure step. This method is both high-throughput and low-cost, which is a powerful tool for future infra-red metamaterials applications. PMID:24284941
Twelkmeyer, Brigitte; Tardif, Nicolas; Rooyackers, Olav
2017-05-01
The purpose of this review is to recapture recent advances in cachexia-related diseases, mainly cancer cachexia, and treatment using genomic, transcriptomics, proteomic, and metabolomics-related techniques. From recent studies in the cancer cachexia field it is clear that the tumor has a direct effect on distant organs via its secretome. The affected pathways on the other hand were largely known from earlier studies with changes in energy-related pathways (mainly lipid metabolism) and the protein degradation pathways. Treatment-oriented studies use mostly rodent models and in-vivo cultures and it is too early for human studies. Omics tools are powerful if used in the right way. Omics research has identified the tumor as an important player in cancer cachexia and some interesting novel treatments have been found in experimental models.
Mathur, Shawn; Schmidt, Christian
2007-01-01
Sovereign power is retained and shared by the citizens of a country. Using electoral tools, governing structures are formed to ensure protection of national interests. As with any institution, proper control of the government guarantees its adherence to the tasks delegated to it by its citizens. In turn, citizens have to be provided with, and are encouraged to access and evaluate, information generated by the government. On the other hand, governments generate sensitive information (e.g., intelligence, internal reports, etc) that are required for self-evaluation and defense against threats to the nation. Governments are granted a privilege to collect, store and use such information to perform necessary tasks. How far does governmental privilege go relative tothe intrinsic right of citizens to access and evaluate information? PMID:17608934
Dynamical characteristics of surface EMG signals of hand grasps via recurrence plot.
Ouyang, Gaoxiang; Zhu, Xiangyang; Ju, Zhaojie; Liu, Honghai
2014-01-01
Recognizing human hand grasp movements through surface electromyogram (sEMG) is a challenging task. In this paper, we investigated nonlinear measures based on recurrence plot, as a tool to evaluate the hidden dynamical characteristics of sEMG during four different hand movements. A series of experimental tests in this study show that the dynamical characteristics of sEMG data with recurrence quantification analysis (RQA) can distinguish different hand grasp movements. Meanwhile, adaptive neuro-fuzzy inference system (ANFIS) is applied to evaluate the performance of the aforementioned measures to identify the grasp movements. The experimental results show that the recognition rate (99.1%) based on the combination of linear and nonlinear measures is much higher than those with only linear measures (93.4%) or nonlinear measures (88.1%). These results suggest that the RQA measures might be a potential tool to reveal the sEMG hidden characteristics of hand grasp movements and an effective supplement for the traditional linear grasp recognition methods.
When pliers become fingers in the monkey motor system
Umiltà, M. A.; Escola, L.; Intskirveli, I.; Grammont, F.; Rochat, M.; Caruana, F.; Jezzini, A.; Gallese, V.; Rizzolatti, G.
2008-01-01
The capacity to use tools is a fundamental evolutionary achievement. Its essence stands in the capacity to transfer a proximal goal (grasp a tool) to a distal goal (e.g., grasp food). Where and how does this goal transfer occur? Here, we show that, in monkeys trained to use tools, cortical motor neurons, active during hand grasping, also become active during grasping with pliers, as if the pliers were now the hand fingers. This motor embodiment occurs both for normal pliers and for “reverse pliers,” an implement that requires finger opening, instead of their closing, to grasp an object. We conclude that the capacity to use tools is based on an inherently goal-centered functional organization of primate cortical motor areas. PMID:18238904
Kapetanakis, Myron; Zhou, Wu; Oxley, Mark P.; ...
2015-09-25
Photon-based spectroscopies have played a central role in exploring the electronic properties of crystalline solids and thin films. They are a powerful tool for probing the electronic properties of nanostructures, but they are limited by lack of spatial resolution. On the other hand, electron-based spectroscopies, e.g., electron energy loss spectroscopy (EELS), are now capable of subangstrom spatial resolution. Core-loss EELS, a spatially resolved analog of x-ray absorption, has been used extensively in the study of inhomogeneous complex systems. In this paper, we demonstrate that low-loss EELS in an aberration-corrected scanning transmission electron microscope, which probes low-energy excitations, combined with amore » theoretical framework for simulating and analyzing the spectra, is a powerful tool to probe low-energy electron excitations with atomic-scale resolution. The theoretical component of the method combines density functional theory–based calculations of the excitations with dynamical scattering theory for the electron beam. We apply the method to monolayer graphene in order to demonstrate that atomic-scale contrast is inherent in low-loss EELS even in a perfectly periodic structure. The method is a complement to optical spectroscopy as it probes transitions entailing momentum transfer. The theoretical analysis identifies the spatial and orbital origins of excitations, holding the promise of ultimately becoming a powerful probe of the structure and electronic properties of individual point and extended defects in both crystals and inhomogeneous complex nanostructures. The method can be extended to probe magnetic and vibrational properties with atomic resolution.« less
Influence of crank length and crank width on maximal hand cycling power and cadence.
Krämer, Christian; Hilker, Lutz; Böhm, Harald
2009-07-01
The effect of different crank lengths and crank widths on maximal hand cycling power, cadence and handle speed were determined. Crank lengths and crank widths were adapted to anthropometric data of the participants as the ratio to forward reach (FR) and shoulder breadth (SB), respectively. 25 able-bodied subjects performed maximal inertial load hand cycle ergometry using crank lengths of 19, 22.5 and 26% of FR and 72, 85 and 98% of SB. Maximum power ranged from 754 (246) W for the crank geometry short wide (crank length x crank width) to 873 (293) W for the combination long middle. Every crank length differed significantly (P < 0.05) from each other, whereas no significant effect of crank width to maximum power output was revealed. Optimal cadence decreased significantly (P < 0.001) with increasing crank length from 124.8 (0.9) rpm for the short to 107.5 (1.6) rpm for the long cranks, whereas optimal handle speed increased significantly (P < 0.001) with increasing crank length from 1.81 (0.01) m/s for the short to 2.13 (0.03) m/s for the long cranks. Crank width did neither influence optimal cadence nor optimal handle speed significantly. From the results of this study, for maximum hand cycling power, a crank length to FR ratio of 26% for a crank width to SB ratio of 85% is recommended.
6. REMAINS OF WATER POWERED MACHINERY USED TO POWER GRIST ...
6. REMAINS OF WATER POWERED MACHINERY USED TO POWER GRIST MILL. NOTE BELT HANGING FROM WOODEN WHEEL IN UPPER RIGHT HAND CORNER OF PHOTOGRAPH. - Plante Grist Mill, U.S. Route 44, Chepachet, Providence County, RI
Jiang, Tianxiao; Liu, Su; Pellizzer, Giuseppe; Aydoseli, Aydin; Karamursel, Sacit; Sabanci, Pulat A.; Sencer, Altay; Gurses, Candan; Ince, Nuri F.
2018-01-01
Functional mapping of eloquent cortex before the resection of a tumor is a critical procedure for optimizing survival and quality of life. In order to locate the hand area of the motor cortex in two patients with low-grade gliomas (LGG), we recorded electrocorticogram (ECoG) from a 113 channel hybrid high-density grid (64 large contacts with diameter of 2.7 mm and 49 small contacts with diameter of 1 mm) while they executed hand clenching movements. We investigated the spatio-spectral characteristics of the neural oscillatory activity and observed that, in both patients, the hand movements were consistently associated with a wide spread power decrease in the low frequency band (LFB: 8–32 Hz) and a more localized power increase in the high frequency band (HFB: 60–280 Hz) within the sensorimotor region. Importantly, we observed significant power increase in the ultra-high frequency band (UFB: 300–800 Hz) during hand movements of both patients within a restricted cortical region close to the central sulcus, and the motor cortical “hand knob.” Among all frequency bands we studied, the UFB modulations were closest to the central sulcus and direct cortical stimulation (DCS) positive site. Both HFB and UFB modulations exhibited different timing characteristics at different locations. Power increase in HFB and UFB starting before movement onset was observed mostly at the anterior part of the activated cortical region. In addition, the spatial patterns in HFB and UFB indicated a probable postcentral shift of the hand motor function in one of the patients. We also compared the task related subband modulations captured by the small and large contacts in our hybrid grid. We did not find any significant difference in terms of band power changes. This study shows initial evidence that event-driven neural oscillatory activity recorded from ECoG can reach up to 800 Hz. The spatial distribution of UFB oscillations was found to be more focalized and closer to the central sulcus compared to LFB and HFB. More studies are needed to characterize further the functional significance of UFB relative to LFB and HFB. PMID:29535603
Jiang, Tianxiao; Liu, Su; Pellizzer, Giuseppe; Aydoseli, Aydin; Karamursel, Sacit; Sabanci, Pulat A; Sencer, Altay; Gurses, Candan; Ince, Nuri F
2018-01-01
Functional mapping of eloquent cortex before the resection of a tumor is a critical procedure for optimizing survival and quality of life. In order to locate the hand area of the motor cortex in two patients with low-grade gliomas (LGG), we recorded electrocorticogram (ECoG) from a 113 channel hybrid high-density grid (64 large contacts with diameter of 2.7 mm and 49 small contacts with diameter of 1 mm) while they executed hand clenching movements. We investigated the spatio-spectral characteristics of the neural oscillatory activity and observed that, in both patients, the hand movements were consistently associated with a wide spread power decrease in the low frequency band (LFB: 8-32 Hz) and a more localized power increase in the high frequency band (HFB: 60-280 Hz) within the sensorimotor region. Importantly, we observed significant power increase in the ultra-high frequency band (UFB: 300-800 Hz) during hand movements of both patients within a restricted cortical region close to the central sulcus, and the motor cortical "hand knob." Among all frequency bands we studied, the UFB modulations were closest to the central sulcus and direct cortical stimulation (DCS) positive site. Both HFB and UFB modulations exhibited different timing characteristics at different locations. Power increase in HFB and UFB starting before movement onset was observed mostly at the anterior part of the activated cortical region. In addition, the spatial patterns in HFB and UFB indicated a probable postcentral shift of the hand motor function in one of the patients. We also compared the task related subband modulations captured by the small and large contacts in our hybrid grid. We did not find any significant difference in terms of band power changes. This study shows initial evidence that event-driven neural oscillatory activity recorded from ECoG can reach up to 800 Hz. The spatial distribution of UFB oscillations was found to be more focalized and closer to the central sulcus compared to LFB and HFB. More studies are needed to characterize further the functional significance of UFB relative to LFB and HFB.
NASA Technical Reports Server (NTRS)
Peters, Gregory
2010-01-01
A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni/Cad rechargeable battery. Power usage was less than 1 Wh/ cm3 even when sampling strong basalts, so many samples could be taken on a single battery charge.
Three Degree of Freedom Parallel Mechanical Linkage
NASA Technical Reports Server (NTRS)
Adelstein, Bernard D. (Inventor)
1998-01-01
A three degree of freedom parallel mechanism or linkage that couples three degree of freedom translational displacements at an endpoint, such as a handle, a hand grip, or a robot tool, to link rotations about three axes that are fixed with respect to a common base or ground link. The mechanism includes a three degree of freedom spherical linkage formed of two closed loops, and a planar linkage connected to the endpoint. The closed loops are rotatably interconnected, and made of eight rigid links connected by a plurality of single degree of freedom revolute joints. Three of these revolute joints are base joints and are connected to a common ground. such that the axis lines passing through the revolute joints intersect at a common fixed center point K forming the center of a spherical work volume in which the endpoint is capable of moving. 'Me three degrees of freedom correspond to the spatial displacement of the endpoint, for instance. The mechanism provides a new overall spatial kinematic linkage composed of a minimal number of rigid links and rotary joints. The mechanism has improved mechanical stiffness, and conveys mechanical power bidirectionally between the human operator and the electromechanical actuators. It does not require gears, belts. cable, screw or other types of transmission elements, and is useful in applications requiring full backdrivability. Thus, this invention can serve as the mechanical linkage for actively powered devices such as compliant robotic manipulators and force-reflecting hand controllers, and passive devices such as manual input devices for computers and other systems.
Planning maximally smooth hand movements constrained to nonplanar workspaces.
Liebermann, Dario G; Krasovsky, Tal; Berman, Sigal
2008-11-01
The article characterizes hand paths and speed profiles for movements performed in a nonplanar, 2-dimensional workspace (a hemisphere of constant curvature). The authors assessed endpoint kinematics (i.e., paths and speeds) under the minimum-jerk model assumptions and calculated minimal amplitude paths (geodesics) and the corresponding speed profiles. The authors also calculated hand speeds using the 2/3 power law. They then compared modeled results with the empirical observations. In all, 10 participants moved their hands forward and backward from a common starting position toward 3 targets located within a hemispheric workspace of small or large curvature. Comparisons of modeled observed differences using 2-way RM-ANOVAs showed that movement direction had no clear influence on hand kinetics (p < .05). Workspace curvature affected the hand paths, which seldom followed geodesic lines. Constraining the paths to different curvatures did not affect the hand speed profiles. Minimum-jerk speed profiles closely matched the observations and were superior to those predicted by 2/3 power law (p < .001). The authors conclude that speed and path cannot be unambiguously linked under the minimum-jerk assumption when individuals move the hand in a nonplanar 2-dimensional workspace. In such a case, the hands do not follow geodesic paths, but they preserve the speed profile, regardless of the geometric features of the workspace.
Geu, Matthew; Madsen, Robert; Weber, Erica; Burnett, Michael; Barrett, Steven
2006-01-01
Several tricycles, one a customized power assisted tricycle, and the second a hand powered tricycle were developed, which offered a unique opportunity to serve multiple purposes in several children's development throughout Wyoming. In Both cases these tricycles provide the children with the opportunity to gain muscle mass, strength, coordination, and confidence. The power assisted tricycle was completed as a senior design project in 2002, and over time safety enhancements have been completed to make the tricycle safer for operation. Unfortunately, the safety system enhancements were not acceptable for it to be released for use. For this reason the tricycle was further redesigned to include more redundant safety systems which will allow the tricycle to be safe for the child's use. The second tricycle was designed to allow for a group of children who have limited use of their legs, to be able to use the same tricycle to give them more upper body strength. A gear system using multiple gear sprockets was adapted to a preexisting tricycle to provide hand power rather than foot power. Without these improvements, the children would not have the opportunity to use these tricycles to help with their development.
Melorheostosis of the hand in a 7-year-old girl.
Sommer, Andrea; Voelker, Thomas; Scheer, Ianina; Roth, Johannes; Keitzer, Rolf; Amthauer, Holger; Stöver, Brigitte
2005-12-01
Melorheostosis of the hand is rare. We report a 7-year-old girl who presented with a contracture of the left hand. Diagnosis was made by conventional radiography and bone scintigraphy. MRI proved to be a very useful tool to visualize the soft-tissue changes. This is especially important when surgical repair is considered.
Perceptual impairment and psychomotor control in virtual laparoscopic surgery.
Wilson, Mark R; McGrath, John S; Vine, Samuel J; Brewer, James; Defriend, David; Masters, Richard S W
2011-07-01
It is recognised that one of the major difficulties in performing laparoscopic surgery is the translation of two-dimensional video image information to a three-dimensional working area. However, research has tended to ignore the gaze and eye-hand coordination strategies employed by laparoscopic surgeons as they attempt to overcome these perceptual constraints. This study sought to examine if measures related to tool movements, gaze strategy, and eye-hand coordination (the quiet eye) differentiate between experienced and novice operators performing a two-handed manoeuvres task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Twenty-five right-handed surgeons were categorised as being either experienced (having led more than 60 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The 10 experienced and 15 novice surgeons completed the "two-hand manoeuvres" task from the LAP Mentor basic skills learning environment while wearing a gaze registration system. Performance, movement, gaze, and eye-hand coordination parameters were recorded and compared between groups. The experienced surgeons completed the task significantly more quickly than the novices, used significantly fewer movements, and displayed shorter tool paths. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. A more detailed analysis of a difficult subcomponent of the task revealed that experienced operators used a significantly longer aiming fixation (the quiet eye period) to guide precision grasping movements and hence needed fewer grasp attempts. The findings of the study provide further support for the utility of examining strategic gaze behaviour and eye-hand coordination measures to help further our understanding of how experienced surgeons attempt to overcome the perceptual difficulties inherent in the laparoscopic environment.
NASA Astrophysics Data System (ADS)
Doran, Rosa
Bringing space exploration recent results and future challenges and opportunities to the knowledge of students has been a preoccupation of educators and space agencies for quite some time. The will to foster student’s interest and reawaken their interest for science topics and in particular research is something occupying the minds of educators in all corners of the globe. But the challenge is growing literally at the speed of light. We are in the age of “Big Data”. Information is available, opportunities to build smart algorithms flourishing. The problem at hand is how we are going to make use of all this possibilities. How can we prepare students to the challenges already upon them? How can we create a scientifically literate and conscious new generation? They are the future of mankind and therefore this is a priority and should quickly be recognized as such. Empowering teachers for this challenge is the key to face the challenges and hold the opportunities. Teachers and students need to learn how to establish fruitful collaboration in the pursuit of meaningful teaching and learning experiences. Teachers need to embrace the opportunities this ICT world is offering and accompany student’s path as tutors and not as explorers themselves. In this training session we intend to explore tools and repositories that bring real cutting edge science to the hands of educators and their students. A full space exploration will be revealed. Planetarium Software - Some tools tailored to prepare an observing session or to explore space mission’s results will be presented in this topic. Participants will also have the opportunity to learn how to plan an observing session. This reveals to be an excellent tool to teach about celestial movements and give students a sense of what it means to explore for instance the Solar System. Robotic Telescopes and Radio Antennas - Having planned an observing session the participants will be introduced to the use of robotic telescopes, a very powerful tool that allows educators to address a diversity of topics ranging from ICT tools to the Exploration of our Universe. Instead of using traditional methods to teach about certain subjects for instance: stellar spectra, extra-solar planets or the classification of galaxies, they can use these powerful tools. Among other advantages a clear benefit of such tool is that teachers can use telescopes during regular classroom hours, provided they choose one located in the opposite part of the planet, where it is night time. Participants will also have the opportunity to use one of the radio antennas devoted for education from the EUHOU Consortium (European Hands-on Universe). A map of the arms of our galaxy will be built during the training session. Image Processing - After acquiring the images participants will be introduced to Salsa J, an image processing software that allows educators to explore the potential of astronomical images. The first example will be a simple measurement task: measuring craters on the Moon. Further exploration will guide them from luminosity studies to the construction of colour images, from making movies exhibiting the circular motion of the Sun to Jupiter Moons dance around the planet. e-learning repositories - In the ICT age it is very important that educators have support and know where to find meaningful and curriculum adapted resources for the construction of modern lessons. Some repositories will be presented in this session. Examples of such repositories are: Discover the Cosmos and EUHOU or a congregator of such repositories with quite advanced possibilities to support the work of teachers, the Open Discovery Space portal. This type of sessions are being successfully implemented by the Galileo Teacher Training Program team in Portugal under the scope of the EC funded GO-LAB project. This is a project devoted to demonstrate innovative ways to involve teachers and students in e-Science through the use of virtual labs, that simulate experiments, in order to spark young people’s interest in science and in following scientific careers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chen; Wang, Jianhui; Ton, Dan
Recent severe power outages caused by extreme weather hazards have highlighted the importance and urgency of improving the resilience of the electric power grid. As the distribution grids still remain vulnerable to natural disasters, the power industry has focused on methods of restoring distribution systems after disasters in an effective and quick manner. The current distribution system restoration practice for utilities is mainly based on predetermined priorities and tends to be inefficient and suboptimal, and the lack of situational awareness after the hazard significantly delays the restoration process. As a result, customers may experience an extended blackout, which causes largemore » economic loss. On the other hand, the emerging advanced devices and technologies enabled through grid modernization efforts have the potential to improve the distribution system restoration strategy. However, utilizing these resources to aid the utilities in better distribution system restoration decision-making in response to extreme weather events is a challenging task. Therefore, this paper proposes an integrated solution: a distribution system restoration decision support tool designed by leveraging resources developed for grid modernization. We first review the current distribution restoration practice and discuss why it is inadequate in response to extreme weather events. Then we describe how the grid modernization efforts could benefit distribution system restoration, and we propose an integrated solution in the form of a decision support tool to achieve the goal. The advantages of the solution include improving situational awareness of the system damage status and facilitating survivability for customers. The paper provides a comprehensive review of how the existing methodologies in the literature could be leveraged to achieve the key advantages. The benefits of the developed system restoration decision support tool include the optimal and efficient allocation of repair crews and resources, the expediting of the restoration process, and the reduction of outage durations for customers, in response to severe blackouts due to extreme weather hazards.« less
NASA Technical Reports Server (NTRS)
Saini, Subhash; Frumkin, Michael; Hribar, Michelle; Jin, Hao-Qiang; Waheed, Abdul; Yan, Jerry
1998-01-01
Porting applications to new high performance parallel and distributed computing platforms is a challenging task. Since writing parallel code by hand is extremely time consuming and costly, porting codes would ideally be automated by using some parallelization tools and compilers. In this paper, we compare the performance of the hand written NAB Parallel Benchmarks against three parallel versions generated with the help of tools and compilers: 1) CAPTools: an interactive computer aided parallelization too] that generates message passing code, 2) the Portland Group's HPF compiler and 3) using compiler directives with the native FORTAN77 compiler on the SGI Origin2000.
Modeling strength data for CREW CHIEF
NASA Technical Reports Server (NTRS)
Mcdaniel, Joe W.
1990-01-01
The Air Force has developed CREW CHIEF, a computer-aided design (CAD) tool for simulating and evaluating aircraft maintenance to determine if the required activities are feasible. CREW CHIEF gives the designer the ability to simulate maintenance activities with respect to reach, accessibility, strength, hand tool operation, and materials handling. While developing the CREW CHIEF, extensive research was performed to describe workers strength capabilities for using hand tools and manual handling of objects. More than 100,000 strength measures were collected and modeled for CREW CHIEF. These measures involved both male and female subjects in the 12 maintenance postures included in CREW CHIEF. The data collection and modeling effort are described.
Mengelkoch, Larry J; Highsmith, M Jason; Morris, Merry L
2014-09-01
Mobility devices for dancers with physical mobility impairments have previously been limited to traditional manual or power wheelchairs. The hands-free torso-controlled mobility chair is a unique powered mobility device which allows greater freedom and expression of movement of the trunk and upper extremities. This study compared differences in energy expenditure during a standardized dance activity using three mobility devices: the hands-free torso-controlled mobility chair, a manual sports wheelchair with hand-arm control, and an electric power chair with hand-joystick control. An experienced dancer with C7 incomplete spinal cord injury (SCI) and an experienced able-bodied dancer were recruited for testing. Three measurement trials were obtained for each chair per subject. Oxygen uptake (VO2) and heart rate (HR) were measured continuously during the dance activity. Immediately following the dance activity, subjects rated perceived exertion. Significant differences (p ≤ 0.05) and similar linear patterns in VO2 and HR responses were observed between chairs for both dancers. When the hands-free mobility chair was used, the dance activity required a moderate level of energy expenditure compared to the manual sports chair or electric power chair for both dancers. Higher ratings of perceived exertion were observed in the manual chair compared to the other chairs for the dancer with SCI, but were similar between chairs for the able-bodied dancer. These results suggest that for a dancer with high-level SCI, the hands-free torso-controlled mobility chair may offer improved freedom and expressive movement possibilities and is an energy-efficient mobility device.
Why Is Hand Washing So Important? (For Parents)
... sneezing after being outside (playing, gardening, walking the dog, etc.) Don't underestimate the power of hand washing! ... Poisoning Diarrhea Tips From School Nurses on Keeping Students Healthy " ...
Protocols and participatory democracy in a 'North-South' product development partnership.
Montgomery, Catherine M
2012-09-01
Global product development partnerships (PDPs) for new health technologies have become an increasingly important part of the science and development landscape over the past two decades. Polarised positions are adopted by those scrutinising the power and governance of these public-private formations; on the one hand, they are seen as successful social technology innovations, on the other as regressive and imperialistic regimes of neo-colonialism. Answering recent calls for research to examine the actors, governance, context and dynamics of PDPs, this article presents a sociological case study of one particular partnership, the Microbicides Development Programme (MDP). Interviews were conducted with a cross-section of programme staff in the UK and Zambia, and discourses analysed through a Foucauldian lens of governmentality. This article suggests that two tools of government were central to MDP's cohesiveness: institutional discourses of participatory democracy and capacity building and scientific protocols. Through these material-semiotic tools, the scientific community, junior operational researchers and the funder were successfully enrolled into the programme and governed by a central body based in the UK. This article draws on Nikolas Rose's work to discuss these socio-scientific discourses as technologies of government, and provides a non-dualistic account of power and governance in a North-South PDP. © 2012 The Author. Sociology of Health & Illness © 2012 Foundation for the Sociology of Health & Illness/Blackwell Publishing Ltd.
Development of Hand-Held Thermographic Inspection Technologies
DOT National Transportation Integrated Search
2009-09-01
This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detectin...
Development of hand-held thermographic inspection technologies.
DOT National Transportation Integrated Search
2009-09-01
This study explored the application of hand-held thermographic cameras for the detection of subsurface delaminations in concrete : bridges. The goal of the research was to provide maintenance and inspection personnel with an effective tool for detect...
Morphology of muscle attachment sites in the modern human hand does not reflect muscle architecture.
Williams-Hatala, E M; Hatala, K G; Hiles, S; Rabey, K N
2016-06-23
Muscle attachment sites (entheses) on dry bones are regularly used by paleontologists to infer soft tissue anatomy and to reconstruct behaviors of extinct organisms. This method is commonly applied to fossil hominin hand bones to assess their abilities to participate in Paleolithic stone tool behaviors. Little is known, however, about how or even whether muscle anatomy and activity regimes influence the morphologies of their entheses, especially in the hand. Using the opponens muscles from a sample of modern humans, we tested the hypothesis that aspects of hand muscle architecture that are known to be influenced by behavior correlate with the size and shape of their associated entheses. Results show no consistent relationships between these behaviorally-influenced aspects of muscle architecture and entheseal morphology. Consequently, it is likely premature to infer patterns of behavior, such as stone tool making in fossil hominins, from these same entheses.
Morphology of muscle attachment sites in the modern human hand does not reflect muscle architecture
Williams-Hatala, E. M.; Hatala, K. G.; Hiles, S.; Rabey, K. N.
2016-01-01
Muscle attachment sites (entheses) on dry bones are regularly used by paleontologists to infer soft tissue anatomy and to reconstruct behaviors of extinct organisms. This method is commonly applied to fossil hominin hand bones to assess their abilities to participate in Paleolithic stone tool behaviors. Little is known, however, about how or even whether muscle anatomy and activity regimes influence the morphologies of their entheses, especially in the hand. Using the opponens muscles from a sample of modern humans, we tested the hypothesis that aspects of hand muscle architecture that are known to be influenced by behavior correlate with the size and shape of their associated entheses. Results show no consistent relationships between these behaviorally-influenced aspects of muscle architecture and entheseal morphology. Consequently, it is likely premature to infer patterns of behavior, such as stone tool making in fossil hominins, from these same entheses. PMID:27334440
NASA Astrophysics Data System (ADS)
Zhang, G. Q.; To, S.
2014-08-01
Cutting force and its power spectrum analysis was thought to be an effective method monitoring tool wear in many cutting processes and a significant body of research has been conducted on this research area. However, relative little similar research was found in ultra-precision fly cutting. In this paper, a group of experiments were carried out to investigate the cutting forces and its power spectrum characteristics under different tool wear stages. Result reveals that the cutting force increases with the progress of tool wear. The cutting force signals under different tool wear stages were analyzed using power spectrum analysis. The analysis indicates that a characteristic frequency does exist in the power spectrum of the cutting force, whose power spectral density increases with the increasing of tool wear level, this characteristic frequency could be adopted to monitor diamond tool wear in ultra-precision fly cutting.
Prehensile control of a hand prosthesis by a microcontroller.
Chappell, P H; Kyberd, P J
1991-09-01
The functional replacement of a natural hand and wrist is usually achieved by a split hook or an electrically powered and myoelectrically controlled artificial hand with one degree of freedom. In contrast to the commercial devices, this paper describes an experimental hand with four electric motors, nineteen sensors, and control algorithms which are written for a microcontroller. The hand significantly improves the prehension capabilities of an artificial device and leads to a design which is easily controlled by a user as it mimics the control system of the natural hand.
Radiation Mitigation and Power Optimization Design Tools for Reconfigurable Hardware in Orbit
NASA Technical Reports Server (NTRS)
French, Matthew; Graham, Paul; Wirthlin, Michael; Wang, Li; Larchev, Gregory
2005-01-01
The Reconfigurable Hardware in Orbit (RHinO)project is focused on creating a set of design tools that facilitate and automate design techniques for reconfigurable computing in space, using SRAM-based field-programmable-gate-array (FPGA) technology. In the second year of the project, design tools that leverage an established FPGA design environment have been created to visualize and analyze an FPGA circuit for radiation weaknesses and power inefficiencies. For radiation, a single event Upset (SEU) emulator, persistence analysis tool, and a half-latch removal tool for Xilinx/Virtex-II devices have been created. Research is underway on a persistence mitigation tool and multiple bit upsets (MBU) studies. For power, synthesis level dynamic power visualization and analysis tools have been completed. Power optimization tools are under development and preliminary test results are positive.
Hand tool permits shrink sizing of assembled tubing
NASA Technical Reports Server (NTRS)
Millett, A.; Odor, M.
1966-01-01
Portable tool sizes tubing ends without disassembling the tubing installation. The shrink sizing tool is clamped to the tubing and operated by a ratchet wrench. A gear train forces the tubing end against an appropriate die or mandrel to effect the sizing.
Routine hand hygiene audit by direct observation: has nemesis arrived?
Gould, D J; Drey, N S; Creedon, S
2011-04-01
Infection prevention and control experts have expended valuable health service time developing and implementing tools to audit health workers' hand hygiene compliance by direct observation. Although described as the 'gold standard' approach to hand hygiene audit, this method is labour intensive and may be inaccurate unless performed by trained personnel who are regularly monitored to ensure quality control. New technological devices have been developed to generate 'real time' data, but the cost of installing them and using them during routine patient care has not been evaluated. Moreover, they do not provide as much information about the hand hygiene episode or the context in which hand hygiene has been performed as direct observation. Uptake of hand hygiene products offers an inexpensive alternative to direct observation. Although product uptake would not provide detailed information about the hand hygiene episode or local barriers to compliance, it could be used as a continuous monitoring tool. Regular inspection of the data by infection prevention and control teams and clinical staff would indicate when and where direct investigation of practice by direct observation and questioning of staff should be targeted by highly trained personnel to identify local problems and improve practice. Copyright © 2011 the Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures.
Tirloni, Adriana Seára; Reis, Diogo Cunha Dos; Ramos, Eliane; Moro, Antônio Renato Pereira
2017-07-26
Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student's t test or Wilcoxon were used ( p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife ( p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife ( p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers' hands.
Thermographic Evaluation of the Hands of Pig Slaughterhouse Workers Exposed to Cold Temperatures
Ramos, Eliane
2017-01-01
Brazil was rated the fourth leading producer and exporter of pork meat in the world. The aim of this study was to evaluate the temperature of the hands of pig slaughterhouse workers and its relation to the thermal sensation of the hands and the use of a cutting tool. The study included 106 workers in a pig slaughterhouse. An infrared camera FlirThermaCAM E320 (Flir Systems, Wilsonville, OR, USA) was used to collect the images of the dorsal and palmar surfaces of both hands. A numerical scale was used to obtain the thermal sensation. Chi-square test, Pearson correlation and Student’s t test or Wilcoxon were used (p ≤ 0.05). The majority of workers felt cold in the hands (66%) and workers who used the knife felt the coldest. There was an association between the thermal sensation and the use of knife (p = 0.001). Workers who used the tool showed correlation between the thermal sensation and the temperatures of the left fingers, with a difference between the temperatures of the right and left hands of those who used the knife (p ≤ 0.05). The hands (left) that manipulated the products presented the lowest temperatures. Findings indicate that employers of pig slaughterhouses should provide gloves with adequate thermal insulation to preserve the health of workers’ hands. PMID:28933764
Beyond Consolidation: U.S. Government International Broadcasting in the Post-Cold War Era
1994-01-01
vii A c kowledgments .......................................... xiii 1. INTRODUCTION ....................................... 1 2. THE UNITED STATES IN...military power more generally, is diminishing in relevance, paced by the decline of U.S. economic preponderance. The difference between military and...economic power on the one hand, and political and moral authority on the other hand, has been made starkly clear at the beginning of the post-Cold War era
Standardized Curriculum for Machine Tool Operation/Machine Shop.
ERIC Educational Resources Information Center
Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.
Standardized vocational education course titles and core contents for two courses in Mississippi are provided: machine tool operation/machine shop I and II. The first course contains the following units: (1) orientation; (2) shop safety; (3) shop math; (4) measuring tools and instruments; (5) hand and bench tools; (6) blueprint reading; (7)…
Hakkers, C S; Beunders, A J M; Ensing, M H M; Barth, R E; Boelema, S; Devillé, W L J; Tempelman, H A; Coutinho, R A; Hoepelman, A I M; Arends, J E; van Zandvoort, M J E
2018-02-01
HIV-associated neurocognitive disorders (HAND) are frequently occurring comorbidities in HIV-positive patients, diagnosed by means of a neuropsychological assessment (NPA). Due to the magnitude of the HIV-positive population in Sub-Saharan Africa, easy-to-use cognitive screening tools are essential. This was a cross-sectional clinical trial involving 44 HIV-positive patients (on stable cART) and 73 HIV-negative controls completing an NPA, the International HIV Dementia Scale (IHDS), and a culturally appropriate cognitive screening tool, the Montreal Cognitive Assessment-Basic (MoCA-B). HAND were diagnosed by calculating Z-scores using internationally published normative data on NPA, as well as by using data from the HIV-negative group to validate the MoCA-B. One hundred and seventeen patients were included (25% male, median age 35 years, median 11 years of education). A moderate correlation was found between the MoCA-B and NPA total Z-score (Pearson's r=0.36, p=0.02). Area under the curve (AUC) values for MoCA-B and IHDS were 0.59 and 0.70, respectively. The prevalence of HAND in HIV-positive patients was 66% when calculating Z-scores using published normative data versus 48% when using the data from the present HIV-negative cohort. The MoCA-B appeared not to be a valid screening tool for HAND in this setting. The prevalence of HAND in this setting is high, but appeared overestimated when using published norms. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Can hand laterality be identified through lithic technology?
Bargalló, Amèlia; Mosquera, Marina
2014-01-01
In this paper we present a new method for inferring handedness from lithic evidence. The study was conducted by means of an experimental programme in stone-knapping, after which the resulting lithic products (tools) were analysed. These lithic tools were produced by 15 inexpert knappers (8 right-handed and 7 left-handed), because we were not able to find a statistically significant number of left-handed expert knappers. We considered inexpert knappers to include individuals who had never struck two pebbles together, as well as individuals who were quite familiar with prehistoric tools and had had some degree of practice. The Mann-Whitney U test proved that all of them produced flakes with the same technical features, so within this sample expertise was not a factor that affected the presence or absence of the technical features analysed to determine hand laterality. The results of the experiment indicate that no single variable can be used to determine the laterality of the knapper, but rather the evidence of handedness lies in the combination of several variables. Furthermore, not all the flakes display the entire set of significant features. Therefore this study concludes that it is not possible to determine the handedness of a knapper through a single variable present on his or her flakes, but it may be possible to determine laterality by examining a combination of technical variables on a number of his or her pieces. Archaeologically, only well-preserved knapping events with numerous refitting products can be assigned to a left- or a right-handed knapper.
Point-cloud-to-point-cloud technique on tool calibration for dental implant surgical path tracking
NASA Astrophysics Data System (ADS)
Lorsakul, Auranuch; Suthakorn, Jackrit; Sinthanayothin, Chanjira
2008-03-01
Dental implant is one of the most popular methods of tooth root replacement used in prosthetic dentistry. Computerize navigation system on a pre-surgical plan is offered to minimize potential risk of damage to critical anatomic structures of patients. Dental tool tip calibrating is basically an important procedure of intraoperative surgery to determine the relation between the hand-piece tool tip and hand-piece's markers. With the transferring coordinates from preoperative CT data to reality, this parameter is a part of components in typical registration problem. It is a part of navigation system which will be developed for further integration. A high accuracy is required, and this relation is arranged by point-cloud-to-point-cloud rigid transformations and singular value decomposition (SVD) for minimizing rigid registration errors. In earlier studies, commercial surgical navigation systems from, such as, BrainLAB and Materialize, have flexibility problem on tool tip calibration. Their systems either require a special tool tip calibration device or are unable to change the different tool. The proposed procedure is to use the pointing device or hand-piece to touch on the pivot and the transformation matrix. This matrix is calculated every time when it moves to the new position while the tool tip stays at the same point. The experiment acquired on the information of tracking device, image acquisition and image processing algorithms. The key success is that point-to-point-cloud requires only 3 post images of tool to be able to converge to the minimum errors 0.77%, and the obtained result is correct in using the tool holder to track the path simulation line displayed in graphic animation.
The Performance of Left-Handed Participants on a Preferential Reaching Test
ERIC Educational Resources Information Center
Mamolo, Carla M.; Roy, Eric A.; Bryden, Pamela J.; Rohr, Linda E.
2005-01-01
Previous research in our laboratory has examined the distribution of preferred hand (PH) reaches in working space with right-handed participants. In one study, we examined the effects of tool position and task demands on the frequency of PH reaches with right-handers (Mamolo, Roy, Bryden, & Rohr, 2004). We found that PH reaches were at a maximum…
The Hand Burn Severity (HABS) score: A simple tool for stratifying severity of hand burns.
Bache, Sarah E; Fitzgerald O'Connor, Edmund; Theodorakopoulou, Evgenia; Frew, Quentin; Philp, Bruce; Dziewulski, Peter
2017-02-01
Hand burns represent a unique challenge to the burns team due to the intricate structure and unrivalled functional importance of the hand. The initial assessment and prognosis relies on consideration of the specific site involved as well as depth of the burn. We created a simple severity score that could be used by referring non-specialists and researchers alike. The Hand Burn Severity (HABS) score stratifies hand burns according to severity with a numerical value of between 0 (no burn) and 18 (most severe) per hand. Three independent assessors scored the photographs of 121 burned hands of 106 adult and paediatric patients, demonstrating excellent inter-rater reliability (r=0.91, p<0.0001 on testing with Lin's correlation coefficient). A significant relationship was shown between the HABS score and a reliable binary outcome of the requirement for surgical excision on Mann-Whitney U testing (U=152; Z=9.8; p=0.0001). A receiver operator characteristic (ROC) curve analysis found a cut off score of 5.5, indicating that those with a HABS score below 6 did not require an operation, whereas those with a score above 6 did. The HABS score was shown to be more sensitive and specific that assessment of burn depth alone. The HABS score is a simple to use tool to stratify severity at initial presentation of hand burns which will be useful when referring, and when reporting outcomes. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
The evolutionary history of the hominin hand since the last common ancestor of Pan and Homo
Tocheri, Matthew W; Orr, Caley M; Jacofsky, Marc C; Marzke, Mary W
2008-01-01
Molecular evidence indicates that the last common ancestor of the genus Pan and the hominin clade existed between 8 and 4 million years ago (Ma). The current fossil record indicates the Pan-Homo last common ancestor existed at least 5 Ma and most likely between 6 and 7 Ma. Together, the molecular and fossil evidence has important consequences for interpreting the evolutionary history of the hand within the tribe Hominini (hominins). Firstly, parsimony supports the hypothesis that the hand of the last common ancestor most likely resembled that of an extant great ape overall (Pan, Gorilla, and Pongo), and that of an African ape in particular. Second, it provides a context for interpreting the derived changes to the hand that have evolved in various hominins. For example, the Australopithecus afarensis hand is likely derived in comparison with that of the Pan–Homo last common ancestor in having shorter fingers relative to thumb length and more proximo-distally oriented joints between its capitate, second metacarpal, and trapezium. This evidence suggests that these derived features evolved prior to the intensification of stone tool-related hominin behaviors beginning around 2.5 Ma. However, a majority of primitive features most likely present in the Pan-Homo last common ancestor are retained in the hands of Australopithecus, Paranthropus/early Homo, and Homo floresiensis. This evidence suggests that further derived changes to the hands of other hominins such as modern humans and Neandertals did not evolve until after 2.5 Ma and possibly even later than 1.5 Ma, which is currently the earliest evidence of Acheulian technology. The derived hands of modern humans and Neandertals may indicate a morphological commitment to tool-related manipulative behaviors beyond that observed in other hominins, including those (e.g. H. floresiensis) which may be descended from earlier tool-making species. PMID:18380869
Nilsson, Lisbeth; Durkin, Josephine
2017-10-01
To explore the knowledge necessary for adoption and implementation of the Assessment of Learning Powered mobility use (ALP) tool in different practice settings for both adults and children. To consult with a diverse population of professionals working with adults and children, in different countries and various settings; who were learning about or using the ALP tool, as part of exploring and implementing research findings. Classical grounded theory with a rigorous comparative analysis of data from informants together with reflections on our own rich experiences of powered mobility practice and comparisons with the literature. A core category learning tool use and a new theory of cognizing tool use, with its interdependent properties: motivation, confidence, permissiveness, attentiveness and co-construction has emerged which explains in greater depth what enables the application of the ALP tool. The scientific knowledge base on tool use learning and the new theory conveys the information necessary for practitioner's cognizing how to apply the learning approach of the ALP tool in order to enable tool use learning through powered mobility practice as a therapeutic intervention in its own right. This opens up the possibility for more children and adults to have access to learning through powered mobility practice. Implications for rehabilitation Tool use learning through powered mobility practice is a therapeutic intervention in its own right. Powered mobility practice can be used as a rehabilitation tool with individuals who may not need to become powered wheelchair users. Motivation, confidence, permissiveness, attentiveness and co-construction are key properties for enabling the application of the learning approach of the ALP tool. Labelling and the use of language, together with honing observational skills through viewing video footage, are key to developing successful learning partnerships.
APT, The Phase I tool for HST Cycle 12
NASA Astrophysics Data System (ADS)
Blacker, Brett S.; Bertch, Maria; Curtis, Gary; Douglas, Robert E., Jr.; Krueger, Anthony P.
2002-12-01
In the continuing effort to streamline our systems and improve service to the science community, the Space Telescope Science Institute (STScI) is developing and releasing, APT The Astronomer’s Proposal Tool as the new interface for Hubble Space Telescope (HST) Phase I and Phase II proposal submissions for HST Cycle 12. APT, was formerly called the Scientist’s Expert Assistant (SEA), which started as a prototype effort to try and bring state of the art technology, more visual tools and power into the hands of proposers so that they can optimize the scientific return of their programs as well as HST. Proposing for HST and other missions, consists of requesting observing time and/or archival research funding. This step is called Phase I, where the scientific merit of a proposal is considered by a community based peer-review process. Accepted proposals then proceed thru Phase II, where the observations are specified in sufficient detail to enable scheduling on the telescope. In this paper, we will present our concept and implementation plans for our Phase I development and submission tool, APT. More importantly, we will go behind the scenes and discuss why it’s important for the Science Policies Division (SPD) and other groups at the STScI to have a new submission tool and submission output products. This paper is an update of the status of the HST Phase I Proposal Processing System that was described in the published paper “A New Era for HST Phase I Development and Submission.”
NASA Technical Reports Server (NTRS)
1974-01-01
Space technology utilization for developing tools, adapters, and fixtures and procedures for assembling, installing, and servicing electrical components and equipment are discussed. Some of the items considered are: (1) pivotal screwdriver, (2) termination locator tool for shielded cables, (3) solder application tools, (4) insulation and shield removing tool, and (5) torque wrench adapter for cable connector engaging ring. Diagrams of the various tools and devices are provided.
Cutting holes in fabric-faced panels
NASA Technical Reports Server (NTRS)
Peterson, S. A.
1981-01-01
Tool has 2 carbide inserts that bore clean holes through fibrous material with knifelike slicing action. Cutting edge of insert is curved, with plane inner surface at 30 degree angle to tool axis. Drill press or hand-held drill can be used to hold cutting tool.
Lisasi, Esther; Kulanga, Ahaz; Muiruri, Charles; Killewo, Lucy; Fadhili, Ndimangwa; Mimano, Lucy; Kapanda, Gibson; Tibyampansha, Dativa; Ibrahim, Glory; Nyindo, Mramba; Mteta, Kien; Kessi, Egbert; Ntabaye, Moshi; Bartlett, John
2014-08-01
The Kilimanjaro Christian Medical University (KCMU) College and the Medical Education Partnership Initiative (MEPI) are addressing the crisis in Tanzanian health care manpower by modernizing the college's medical education with new tools and techniques. With a $10 million MEPI grant and the participation of its partner, Duke University, KCMU is harnessing the power of information technology (IT) to upgrade tools for students and faculty. Initiatives in eLearning have included bringing fiber-optic connectivity to the campus, offering campus-wide wireless access, opening student and faculty computer laboratories, and providing computer tablets to all incoming medical students. Beyond IT, the college is also offering wet laboratory instruction for hands-on diagnostic skills, team-based learning, and clinical skills workshops. In addition, modern teaching tools and techniques address the challenges posed by increasing numbers of students. To provide incentives for instructors, a performance-based compensation plan and teaching awards have been established. Also for faculty, IT tools and training have been made available, and a medical education course management system is now being widely employed. Student and faculty responses have been favorable, and the rapid uptake of these interventions by students, faculty, and the college's administration suggests that the KCMU College MEPI approach has addressed unmet needs. This enabling environment has transformed the culture of learning and teaching at KCMU College, where a path to sustainability is now being pursued.
Lisasi, Esther; Kulanga, Ahaz; Muiruri, Charles; Killewo, Lucy; Fadhili, Ndimangwa; Mimano, Lucy; Kapanda, Gibson; Tibyampansha, Dativa; Ibrahim, Glory; Nyindo, Mramba; Mteta, Kien; Kessi, Egbert; Ntabaye, Moshi; Bartlett, John
2014-01-01
The Kilimanjaro Christian Medical University (KCMU) College and the Medical Education Partnership Initiative (MEPI) are addressing the crisis in Tanzanian health care manpower by modernizing the college’s medical education with new tools and techniques. With a $10 million MEPI grant and the participation of its partner, Duke University, KCMU is harnessing the power of information technology (IT) to upgrade tools for students and faculty. Initiatives in eLearning have included bringing fiber-optic connectivity to the campus, offering campus-wide wireless access, opening student and faculty computer laboratories, and providing computer tablets to all incoming medical students. Beyond IT, the college is also offering wet laboratory instruction for hands-on diagnostic skills, team-based learning, and clinical skills workshops. In addition, modern teaching tools and techniques address the challenges posed by increasing numbers of students. To provide incentives for instructors, a performance-based compensation plan and teaching awards have been established. Also for faculty, IT tools and training have been made available, and a medical education course management system is now being widely employed. Student and faculty responses have been favorable, and the rapid uptake of these interventions by students, faculty, and the college’s administration suggests that the KCMU College MEPI approach has addressed unmet needs. This enabling environment has transformed the culture of learning and teaching at KCMU College, where a path to sustainability is now being pursued. PMID:25072581
Spacecraft Electrical Power System (EPS) generic analysis tools and techniques
NASA Technical Reports Server (NTRS)
Morris, Gladys M.; Sheppard, Mark A.
1992-01-01
An overview is provided of the analysis tools and techiques used in modeling the Space Station Freedom electrical power system, as well as future space vehicle power systems. The analysis capabilities of the Electrical Power System (EPS) are described and the EPS analysis tools are surveyed.
Power Plant Model Validation Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
The PPMV is used to validate generator model using disturbance recordings. The PPMV tool contains a collection of power plant models and model validation studies, as well as disturbance recordings from a number of historic grid events. The user can import data from a new disturbance into the database, which converts PMU and SCADA data into GE PSLF format, and then run the tool to validate (or invalidate) the model for a specific power plant against its actual performance. The PNNL PPMV tool enables the automation of the process of power plant model validation using disturbance recordings. The tool usesmore » PMU and SCADA measurements as input information. The tool automatically adjusts all required EPCL scripts and interacts with GE PSLF in the batch mode. The main tool features includes: The tool interacts with GE PSLF; The tool uses GE PSLF Play-In Function for generator model validation; Database of projects (model validation studies); Database of the historic events; Database of the power plant; The tool has advanced visualization capabilities; and The tool automatically generates reports« less
Conger, Scott A; Scott, Stacy N; Bassett, David R
2014-07-01
To examine the relationship between hand rim propulsion power and energy expenditure (EE) during wheelchair wheeling and to investigate whether adding other variables to the model could improve on the prediction of EE. Individuals who use manual wheelchairs (n=14) performed five different wheeling activities in a wheelchair with a PowerTap power meter hub built into the right rear wheel. Activities included wheeling on a smooth, level surface at three different speeds (4.5, 5.5 and 6.5 km/h), wheeling on a rubberised track at one speed (5.5 km/h) and wheeling on a sidewalk course that included uphill and downhill segments at a self-selected speed. EE was measured using a portable indirect calorimetry system. Stepwise linear regression was performed to predict EE from power output variables. A repeated-measures analysis of variance was used to compare the measured EE to the estimates from the power models. Bland-Altman plots were used to assess the agreement between the criterion values and the predicted values. EE and power were significantly correlated (r=0.694, p<0.001). Regression analysis yielded three significant prediction models utilising measured power; measured power and speed; and measured power, speed and heart rate. No significant differences were found between measured EE and any of the prediction models. EE can be accurately and precisely estimated based on hand rim propulsion power. These results indicate that power could be used as a method to assess EE in individuals who use wheelchairs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Hand synergies during reach-to-grasp.
Mason, C R; Gomez, J E; Ebner, T J
2001-12-01
An emerging viewpoint is that the CNS uses synergies to simplify the control of the hand. Previous work has shown that static hand postures for mimed grasps can be described by a few principal components in which the higher order components explained only a small fraction of the variance yet provided meaningful information. Extending that earlier work, this study addressed whether the entire act of grasp can be described by a small number of postural synergies and whether these synergies are similar for different grasps. Five right-handed adults performed five types of reach-to-grasps including power grasp, power grasp with a lift, precision grasp, and mimed power grasp and mimed precision grasp of 16 different objects. The object shapes were cones, cylinders, and spindles, systematically varied in size to produce a large range of finger joint angle combinations. Three-dimensional reconstructions of 21 positions on the hand and wrist throughout the reach-to-grasp were obtained using a four-camera video system. Singular value decomposition on the temporal sequence of the marker positions was used to identify the common patterns ("eigenpostures") across the 16 objects for each task and their weightings as a function of time. The first eigenposture explained an average of 97.3 +/- 0.89% (mean +/- SD) of the variance of the hand shape, and the second another 1.9 +/- 0.85%. The first eigenposture was characterized by an open hand configuration that opens and closes during reach. The second eigenposture contributed to the control of the thumb and long fingers, particularly in the opening of the hand during the reach and the closing in preparation for object grasp. The eigenpostures and their temporal evolutions were similar across subjects and grasps. The higher order eigenpostures, although explaining only small amounts of the variance, contributed to the movements of the fingers and thumb. These findings suggest that much of reach-to-grasp is effected using a base posture with refinements in finger and thumb positions added in time to yield unique hand shapes.
The Role of Motor Learning in Spatial Adaptation near a Tool
Brown, Liana E.; Doole, Robert; Malfait, Nicole
2011-01-01
Some visual-tactile (bimodal) cells have visual receptive fields (vRFs) that overlap and extend moderately beyond the skin of the hand. Neurophysiological evidence suggests, however, that a vRF will grow to encompass a hand-held tool following active tool use but not after passive holding. Why does active tool use, and not passive holding, lead to spatial adaptation near a tool? We asked whether spatial adaptation could be the result of motor or visual experience with the tool, and we distinguished between these alternatives by isolating motor from visual experience with the tool. Participants learned to use a novel, weighted tool. The active training group received both motor and visual experience with the tool, the passive training group received visual experience with the tool, but no motor experience, and finally, a no-training control group received neither visual nor motor experience using the tool. After training, we used a cueing paradigm to measure how quickly participants detected targets, varying whether the tool was placed near or far from the target display. Only the active training group detected targets more quickly when the tool was placed near, rather than far, from the target display. This effect of tool location was not present for either the passive-training or control groups. These results suggest that motor learning influences how visual space around the tool is represented. PMID:22174944
Future Naval Concepts -- Crew Reductions through Improved Damage Control Communications (FNC-CRIDCC)
2007-04-18
10/06 On Hand FNC01013-1014 1 Vostek VRX -24L M Receiver 7/10/06 On Hand FNC01015 1 Vostek VRX -24L MIL Receiver 7/10/06 On Hand FNC01016...1 Vostek VRX -24L Z Receiver 7/10/06 On Hand FNC01017 2 Vostek M-808 Receiver 7/10/06 On Hand FNC01018-1019 2 Vostek HPX-916...Vostek Power Supply 200mA/6V for M-808 7/10/06 On Hand FNC01029-1034 1 Vostek VRX -24LTS/M Receiver 7/10/06 On Hand FNC01035 6 Black Box
Teaching Web Security Using Portable Virtual Labs
ERIC Educational Resources Information Center
Chen, Li-Chiou; Tao, Lixin
2012-01-01
We have developed a tool called Secure WEb dEvelopment Teaching (SWEET) to introduce security concepts and practices for web application development. This tool provides introductory tutorials, teaching modules utilizing virtualized hands-on exercises, and project ideas in web application security. In addition, the tool provides pre-configured…
The Locus of Tool-Transformation Costs
ERIC Educational Resources Information Center
Kunde, Wilfried; Pfister, Roland; Janczyk, Markus
2012-01-01
Transformations of hand movements by tools such as levers or electronic input devices can invoke performance costs compared to untransformed movements. This study investigated by means of the Psychological Refractory Period (PRP) paradigm at which stage of information processing such tool-transformation costs arise. We used an inversion…
Effect of a powered drive on pushing and pulling forces when transporting bariatric hospital beds.
Wiggermann, Neal
2017-01-01
Powered drives designed to assist with moving hospital beds are commercially available but no studies have evaluated whether they reduce the push and pull forces likely contributing to injury in caregivers. This study measured hand forces of 10 caregivers maneuvering a manual and powered bariatric bed through simulated hospital environments (hallway, elevator, and ramp). Peak push and pull forces exceeded previously established psychophysical limits for all activities with the manual bed. For the powered bed, peak forces were significantly (p < 0.05) lower for all tasks, and below psychophysical limits. Powered drive reduced peak forces between 38% (maneuvering into elevator) and 94% (descending ramp). Powered drive also reduced stopping distance by 55%. When maneuvering, the integral of hand force was 34% lower with powered drive, but average forces during straight-line pushing did not differ between beds. Powered drive may reduce the risk of injury or the number of caregivers needed for transport. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yokoyama, Osamu; Nakayama, Yoshihisa
2016-01-01
The caudal cingulate motor area (CMAc) and the supplementary motor area (SMA) play important roles in movement execution. The present study examined the neural mechanisms underlying these roles by investigating local field potentials (LFPs) from these areas while monkeys pressed buttons with either their left or right hand. During hand movement, power increases in the high-gamma (80–120 Hz) and theta (3–8 Hz) bands and a power decrease in the beta (12–30 Hz) band were observed in both the CMAc and SMA. High-gamma and beta activity in the SMA predominantly represented contralateral hand movements, whereas activity in the CMAc preferentially represented movement of either hand. Theta activity in both brain regions most frequently reflected movement of either hand, but a contralateral hand bias was more evident in the SMA than in the CMAc. An analysis of the relationships of the laterality representations between the high-gamma and theta bands at each recording site revealed that, irrespective of the hand preference for the theta band, the high-gamma band in the SMA preferentially represented contralateral hand movement, whereas the high-gamma band in the CMAc represented movement of either hand. These findings suggest that the input-output relationships for ipsilateral and contralateral hand movements in the CMAc and SMA differ in terms of their functionality. The CMAc may transform the input signals representing general aspects of movement into commands to perform movements with either hand, whereas the SMA may transform the input signals into commands to perform movement with the contralateral hand. PMID:26792884
ERIC Educational Resources Information Center
Burke, Victoria; Greenberg, Daphne
2010-01-01
There are many readability tools that instructors can use to help adult learners select reading materials. We describe and compare different types of readability tools: formulas calculated by hand, tools found on the Web, tools embedded in a word processing program, and readability tools found in a commercial software program. Practitioners do not…
Image Analysis of DNA Fiber and Nucleus in Plants.
Ohmido, Nobuko; Wako, Toshiyuki; Kato, Seiji; Fukui, Kiichi
2016-01-01
Advances in cytology have led to the application of a wide range of visualization methods in plant genome studies. Image analysis methods are indispensable tools where morphology, density, and color play important roles in the biological systems. Visualization and image analysis methods are useful techniques in the analyses of the detailed structure and function of extended DNA fibers (EDFs) and interphase nuclei. The EDF is the highest in the spatial resolving power to reveal genome structure and it can be used for physical mapping, especially for closely located genes and tandemly repeated sequences. One the other hand, analyzing nuclear DNA and proteins would reveal nuclear structure and functions. In this chapter, we describe the image analysis protocol for quantitatively analyzing different types of plant genome, EDFs and interphase nuclei.
Hanson, Leanne; Holmquist-Johnson, Christopher L.; Cowardin, Michelle L.
2014-01-01
The Raven sUAS is a hand-launched reconnaissance and data-gathering tool developed for the U.S. Department of Defense by AeroVironment, Inc. Originally designed to provide aerial observation, day or night, at line-of-site ranges up to 6.2 miles (10 kilometers), the Raven sUAS has a wingspan of 4.5 feet (1.38 meters) and weighs 4.2 pounds (1.9 kilograms). A 60-minute lithium-ion rechargeable battery powers the system which also transmits live video (color or infrared imagery), compass headings, and location information to a ground control station. The Raven sUAS is typically operated by a three-person flight crew consisting of a pilot, mission operator, and a trained observer.
Seeing the World in a Grain of Sand
NASA Astrophysics Data System (ADS)
Clucas, T.; Wirth, G. S.
2015-12-01
Enabling people to trigger and to witness landscape change is a powerful method of communicating scientific concepts. Alaska EPSCoR and GINA have found an effective tool for this effort in their "Augmented-Reality Sandbox," an engaging hands-on interface that can be used to teach about topography, hydrology, natural hazards, and landscape change. People are consistently excited about the sandbox, the success of which has led EPSCoR to construct mobile versions which have traveled to remote Alaskan communities. EPSCoR has also developed model curricula that use the sandbox to teach basic topography and hydrology skills, and is working on advanced lessons based around hydrologic and landscape hazards. Instructions on building a mobile sandbox, curricula, and video of the sandbox in action are available at www.alaska.edu/epscor/Augmented-Reality%20Sandbox/
Gamma-Ray Pulsar Light Curves as Probes of Magnetospheric Structure
NASA Technical Reports Server (NTRS)
Harding, A. K.
2016-01-01
The large number of gamma-ray pulsars discovered by the Fermi Gamma-Ray Space Telescope since its launch in 2008 dwarfs the handful that were previously known. The variety of observed light curves makes possible a tomography of both the ensemble-averaged field structure and the high-energy emission regions of a pulsar magnetosphere. Fitting the gamma-ray pulsar light curves with model magnetospheres and emission models has revealed that most of the high-energy emission, and the particles acceleration, takes place near or beyond the light cylinder, near the current sheet. As pulsar magnetosphere models become more sophisticated, it is possible to probe magnetic field structure and emission that are self-consistently determined. Light curve modeling will continue to be a powerful tool for constraining the pulsar magnetosphere physics.
A Multigrasp Hand Prosthesis for Providing Precision and Conformal Grasps
Bennett, Daniel A.; Dalley, Skyler A.; Truex, Don; Goldfarb, Michael
2015-01-01
This paper presents the design of an anthropomorphic prosthetic hand that incorporates four motor units in a unique configuration to explicitly provide both precision and conformal grasp capability. The paper describes the design of the hand prosthesis, and additionally describes the design of an embedded control system located in the palm of the hand that enables self-contained control of hand movement. Following the design description, the paper provides experimental characterizations of hand performance, including digit force capability, bandwidth of digit movement, physical properties such as size and mass, and electrical power measurements during activities of daily living. PMID:26167111
EMU battery/SMM power tool characterization study
NASA Technical Reports Server (NTRS)
Palandati, C.
1982-01-01
The power tool which will be used to replace the attitude control system in the SMM spacecraft was modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery was tested for the power tool application. The results are that the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.
Young Scientist in the Classroom (II)
NASA Astrophysics Data System (ADS)
Doran, Rosa
2016-07-01
Bringing space exploration recent results and future challenges and opportunities has been a preoccupation of educators and space agencies for quite some time. The will to foster student's interest and reawaken their interest for science topics and in particular research is something occupying the minds of educators in all corners of the globe. But the challenge is growing literally at the speed of light. We are in the age of "Big Data". Information is available, opportunities to build smart algorithms flourishing. The problem at hand is how we are going to make use of all this possibilities. How can we prepare students to the challenges already upon them? How can we create a scientifically literate and conscious new generation? They are the future of mankind and therefore this is a priority and should quickly be recognized as such. Empowering teachers for this challenge is the key to face the challenges and hold the opportunities. Teachers and students need to learn how to establish fruitful collaboration in the pursuit of meaningful teaching and learning experiences. Teachers need to embrace the opportunities this ICT world is offering and accompany student's path as tutors and not as explorers themselves. In this training session we intend to explore tools and repositories that bring real cutting edge science to the hands of educators and their students. A full space exploration will be revealed. Planetarium Software - Some tools tailored to prepare an observing session or to explore space mission's results will be presented in this topic. Participants will also have the opportunity to learn how to plan an observing session. This reveals to be an excellent tool to teach about celestial movements and give students a sense of what it means to explore for instance the Solar System. Robotic Telescopes - Having planned an observing session the participants will be introduced to the use of robotic telescopes, a very powerful tool that allows educators to address a diversity of topics ranging from ICT tools to the Exploration of our Universe. Instead of using traditional methods to teach about certain subjects for instance: stellar spectra, extra-solar planets of the classification of galaxies, they can use these powerful tools. Among other advantages a clear benefit of such tool is that teachers can use telescopes during regular classroom hours, provided they choose one located in the opposite part of the planet, where it is night time. Image Processing - After acquiring the images participants will be introduced to Salsa J, an image processing software that allows educators to explore the potential of astronomical images. The first example will be a simple measurement task: measuring craters on the Moon. Further exploration will guide them from luminosity studies until the construction of colour images or movies exhibiting the circular motion of the Sun or Jupiter Moons dance around the planet. Inquiry Based Learning - In the era of big data it is crucial to develop in students the capacity to creatively find solutions to a diversity of problems. In this session we will share with participants new models to engage students in the use of the scientific method while learning curriculum contents. Examples of cutting edge platforms embedding online labs and assessment tools will be explored.
Young Scientist in the Classroom (I)
NASA Astrophysics Data System (ADS)
Doran, Rosa
2016-07-01
Bringing space exploration recent results and future challenges and opportunities has been a preoccupation of educators and space agencies for quite some time. The will to foster student's interest and reawaken their interest for science topics and in particular research is something occupying the minds of educators in all corners of the globe. But the challenge is growing literally at the speed of light. We are in the age of "Big Data". Information is available, opportunities to build smart algorithms flourishing. The problem at hand is how we are going to make use of all this possibilities. How can we prepare students to the challenges already upon them? How can we create a scientifically literate and conscious new generation? They are the future of mankind and therefore this is a priority and should quickly be recognized as such. Empowering teachers for this challenge is the key to face the challenges and hold the opportunities. Teachers and students need to learn how to establish fruitful collaboration in the pursuit of meaningful teaching and learning experiences. Teachers need to embrace the opportunities this ICT world is offering and accompany student's path as tutors and not as explorers themselves. In this training session we intend to explore tools and repositories that bring real cutting edge science to the hands of educators and their students. A full space exploration will be revealed. Planetarium Software - Some tools tailored to prepare an observing session or to explore space mission's results will be presented in this topic. Participants will also have the opportunity to learn how to plan an observing session. This reveals to be an excellent tool to teach about celestial movements and give students a sense of what it means to explore for instance the Solar System. Robotic Telescopes - Having planned an observing session the participants will be introduced to the use of robotic telescopes, a very powerful tool that allows educators to address a diversity of topics ranging from ICT tools to the Exploration of our Universe. Instead of using traditional methods to teach about certain subjects for instance: stellar spectra, extra-solar planets of the classification of galaxies, they can use these powerful tools. Among other advantages a clear benefit of such tool is that teachers can use telescopes during regular classroom hours, provided they choose one located in the opposite part of the planet, where it is night time. Image Processing - After acquiring the images participants will be introduced to Salsa J, an image processing software that allows educators to explore the potential of astronomical images. The first example will be a simple measurement task: measuring craters on the Moon. Further exploration will guide them from luminosity studies until the construction of colour images or movies exhibiting the circular motion of the Sun or Jupiter Moons dance around the planet. Inquiry Based Learning - In the era of big data it is crucial to develop in students the capacity to creatively find solutions to a diversity of problems. In this session we will share with participants new models to engage students in the use of the scientific method while learning curriculum contents. Examples of cutting edge platforms embedding online labs and assessment tools will be explored.
Young Scientist in the Classroom (III)
NASA Astrophysics Data System (ADS)
Doran, Rosa
2016-07-01
Bringing space exploration recent results and future challenges and opportunities has been a preoccupation of educators and space agencies for quite some time. The will to foster student's interest and reawaken their interest for science topics and in particular research is something occupying the minds of educators in all corners of the globe. But the challenge is growing literally at the speed of light. We are in the age of "Big Data". Information is available, opportunities to build smart algorithms flourishing. The problem at hand is how we are going to make use of all this possibilities. How can we prepare students to the challenges already upon them? How can we create a scientifically literate and conscious new generation? They are the future of mankind and therefore this is a priority and should quickly be recognized as such. Empowering teachers for this challenge is the key to face the challenges and hold the opportunities. Teachers and students need to learn how to establish fruitful collaboration in the pursuit of meaningful teaching and learning experiences. Teachers need to embrace the opportunities this ICT world is offering and accompany student's path as tutors and not as explorers themselves. In this training session we intend to explore tools and repositories that bring real cutting edge science to the hands of educators and their students. A full space exploration will be revealed. Planetarium Software - Some tools tailored to prepare an observing session or to explore space mission's results will be presented in this topic. Participants will also have the opportunity to learn how to plan an observing session. This reveals to be an excellent tool to teach about celestial movements and give students a sense of what it means to explore for instance the Solar System. Robotic Telescopes - Having planned an observing session the participants will be introduced to the use of robotic telescopes, a very powerful tool that allows educators to address a diversity of topics ranging from ICT tools to the Exploration of our Universe. Instead of using traditional methods to teach about certain subjects for instance: stellar spectra, extra-solar planets of the classification of galaxies, they can use these powerful tools. Among other advantages a clear benefit of such tool is that teachers can use telescopes during regular classroom hours, provided they choose one located in the opposite part of the planet, where it is night time. Image Processing - After acquiring the images participants will be introduced to Salsa J, an image processing software that allows educators to explore the potential of astronomical images. The first example will be a simple measurement task: measuring craters on the Moon. Further exploration will guide them from luminosity studies until the construction of colour images or movies exhibiting the circular motion of the Sun or Jupiter Moons dance around the planet. Inquiry Based Learning - In the era of big data it is crucial to develop in students the capacity to creatively find solutions to a diversity of problems. In this session we will share with participants new models to engage students in the use of the scientific method while learning curriculum contents. Examples of cutting edge platforms embedding online labs and assessment tools will be explored.
Young Scientist in the Classroom (IV)
NASA Astrophysics Data System (ADS)
Doran, Rosa
2016-07-01
Bringing space exploration recent results and future challenges and opportunities has been a preoccupation of educators and space agencies for quite some time. The will to foster student's interest and reawaken their interest for science topics and in particular research is something occupying the minds of educators in all corners of the globe. But the challenge is growing literally at the speed of light. We are in the age of "Big Data". Information is available, opportunities to build smart algorithms flourishing. The problem at hand is how we are going to make use of all this possibilities. How can we prepare students to the challenges already upon them? How can we create a scientifically literate and conscious new generation? They are the future of mankind and therefore this is a priority and should quickly be recognized as such. Empowering teachers for this challenge is the key to face the challenges and hold the opportunities. Teachers and students need to learn how to establish fruitful collaboration in the pursuit of meaningful teaching and learning experiences. Teachers need to embrace the opportunities this ICT world is offering and accompany student's path as tutors and not as explorers themselves. In this training session we intend to explore tools and repositories that bring real cutting edge science to the hands of educators and their students. A full space exploration will be revealed. Planetarium Software - Some tools tailored to prepare an observing session or to explore space mission's results will be presented in this topic. Participants will also have the opportunity to learn how to plan an observing session. This reveals to be an excellent tool to teach about celestial movements and give students a sense of what it means to explore for instance the Solar System. Robotic Telescopes - Having planned an observing session the participants will be introduced to the use of robotic telescopes, a very powerful tool that allows educators to address a diversity of topics ranging from ICT tools to the Exploration of our Universe. Instead of using traditional methods to teach about certain subjects for instance: stellar spectra, extra-solar planets of the classification of galaxies, they can use these powerful tools. Among other advantages a clear benefit of such tool is that teachers can use telescopes during regular classroom hours, provided they choose one located in the opposite part of the planet, where it is night time. Image Processing - After acquiring the images participants will be introduced to Salsa J, an image processing software that allows educators to explore the potential of astronomical images. The first example will be a simple measurement task: measuring craters on the Moon. Further exploration will guide them from luminosity studies until the construction of colour images or movies exhibiting the circular motion of the Sun or Jupiter Moons dance around the planet. Inquiry Based Learning - In the era of big data it is crucial to develop in students the capacity to creatively find solutions to a diversity of problems. In this session we will share with participants new models to engage students in the use of the scientific method while learning curriculum contents. Examples of cutting edge platforms embedding online labs and assessment tools will be explored.
48 CFR 225.7001 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Mooring Chain. (c) “End product” is defined in the clause at 252.225-7012, Preference for Certain Domestic Commodities. (d) Hand or measuring tools means those tools listed in Federal supply classifications 51 and 52...
48 CFR 225.7001 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Mooring Chain. (c) “End product” is defined in the clause at 252.225-7012, Preference for Certain Domestic Commodities. (d) Hand or measuring tools means those tools listed in Federal supply classifications 51 and 52...
48 CFR 225.7001 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Mooring Chain. (c) “End product” is defined in the clause at 252.225-7012, Preference for Certain Domestic Commodities. (d) Hand or measuring tools means those tools listed in Federal supply classifications 51 and 52...
48 CFR 225.7001 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Mooring Chain. (c) “End product” is defined in the clause at 252.225-7012, Preference for Certain Domestic Commodities. (d) Hand or measuring tools means those tools listed in Federal supply classifications 51 and 52...
48 CFR 225.7001 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Mooring Chain. (c) “End product” is defined in the clause at 252.225-7012, Preference for Certain Domestic Commodities. (d) Hand or measuring tools means those tools listed in Federal supply classifications 51 and 52...
Pilot study of a point-of-use decision support tool for cancer clinical trials eligibility.
Breitfeld, P P; Weisburd, M; Overhage, J M; Sledge, G; Tierney, W M
1999-01-01
Many adults with cancer are not enrolled in clinical trials because caregivers do not have the time to match the patient's clinical findings with varying eligibility criteria associated with multiple trials for which the patient might be eligible. The authors developed a point-of-use portable decision support tool (DS-TRIEL) to automate this matching process. The support tool consists of a hand-held computer with a programmable relational database. A two-level hierarchic decision framework was used for the identification of eligible subjects for two open breast cancer clinical trials. The hand-held computer also provides protocol consent forms and schemas to further help the busy oncologist. This decision support tool and the decision framework on which it is based could be used for multiple trials and different cancer sites.
Pilot Study of a Point-of-use Decision Support Tool for Cancer Clinical Trials Eligibility
Breitfeld, Philip P.; Weisburd, Marina; Overhage, J. Marc; Sledge, George; Tierney, William M.
1999-01-01
Many adults with cancer are not enrolled in clinical trials because caregivers do not have the time to match the patient's clinical findings with varying eligibility criteria associated with multiple trials for which the patient might be eligible. The authors developed a point-of-use portable decision support tool (DS-TRIEL) to automate this matching process. The support tool consists of a hand-held computer with a programmable relational database. A two-level hierarchic decision framework was used for the identification of eligible subjects for two open breast cancer clinical trials. The hand-held computer also provides protocol consent forms and schemas to further help the busy oncologist. This decision support tool and the decision framework on which it is based could be used for multiple trials and different cancer sites. PMID:10579605
Güner, A; Altan, L; Kasapoğlu Aksoy, M
2018-05-01
In mild and moderate cases of carpal tunnel syndrome (CTS), the conservative approach is suggested. The purpose of this study is to assess and compare the effect of low-power laser versus the combination of low-power laser and kinesiotaping on pain, muscle strength, functionality, and electrophysiologic parameters in the patients with CTS. The study was planned as single-blind, prospective, randomized control. 64 hands diagnosed with CTS were included in the study. The patients were randomly divided into three groups by closed envelope method. Low-power laser therapy was applied to Group 1 (21 hands), kinesiotaping and low-power laser therapy in group 2 (22 hands), sham laser therapy in Group 3 (21 hands). All patients were assessed by visual numeric pain scale (VNS), hand grip strength (HGS), finger pinch strength (FPS), the Boston Carpal Tunnel Syndrome Questionnaire (BCTSQ), before treatment, after treatment (3rd week), and after (12th week) 3 months the treatment with the same physician. Motor and sensory nerve conduction studies were performed with electroneuromyography (ENMG) before the treatment (0th week) and at the end of the 12th week. Comparison of the group 1 with the group 3 showed significantly better improvement in the former in VNS, BCTSQ at 3rd week and 12th week compared to 0th week, and in FPS and HGS at 3rd week. Comparison of the group 2 with the group 3 showed significantly better improvement in the former VNS, BCTSQ, FPS and HGS at 3rd and 12th week compared to 0th week. When Group 1 and Group 2 were compared there was no statistically significant difference in any parameters in the 3rd week, but there was a statistically significant difference in favor of group 2 in FPS and HGS parameters at the 12th week. We have found that the kinesiotaping method applied with low-power laser treatment does not provide any additional benefit to the low-power laser treatment in the short term, however, in the long term, the increase in the HGS and FPS has occurred. In conclusion, low-power laser and kinesiotaping method in the treatment of CTS may be an effective and reliable treatment option in clinical parameters.
Exploring the Outdoor Classroom with a Hand Lens.
ERIC Educational Resources Information Center
Rillo, Thomas J.
Information about hand lenses and their use in the classroom and out-of-doors for curriculum enrichment is presented in this paper. Some basic attributes of the hand lens, including shape, focal length, and magnification power, are described. Directions for making holders for the lenses in the classroom are given. Two classroom activities and 14…
Barnes, Brian B.; Wilson, Michael B.; Carr, Peter W.; Vitha, Mark F.; Broeckling, Corey D.; Heuberger, Adam L.; Prenni, Jessica; Janis, Gregory C.; Corcoran, Henry; Snow, Nicholas H.; Chopra, Shilpi; Dhandapani, Ramkumar; Tawfall, Amanda; Sumner, Lloyd W.; Boswell, Paul G.
2014-01-01
Gas chromatography-mass spectrometry (GC-MS) is a primary tool used to identify compounds in complex samples. Both mass spectra and GC retention times are matched to those of standards, but it is often impractical to have standards on hand for every compound of interest, so we must rely on shared databases of MS data and GC retention information. Unfortunately, retention databases (e.g. linear retention index libraries) are experimentally restrictive, notoriously unreliable, and strongly instrument dependent, relegating GC retention information to a minor, often negligible role in compound identification despite its potential power. A new methodology called “retention projection” has great potential to overcome the limitations of shared chromatographic databases. In this work, we tested the reliability of the methodology in five independent laboratories. We found that even when each lab ran nominally the same method, the methodology was 3-fold more accurate than retention indexing because it properly accounted for unintentional differences between the GC-MS systems. When the labs used different methods of their own choosing, retention projections were 4- to 165-fold more accurate. More importantly, the distribution of error in the retention projections was predictable across different methods and labs, thus enabling automatic calculation of retention time tolerance windows. Tolerance windows at 99% confidence were generally narrower than those widely used even when physical standards are on hand to measure their retention. With its high accuracy and reliability, the new retention projection methodology makes GC retention a reliable, precise tool for compound identification, even when standards are not available to the user. PMID:24205931
Differential Inactivation of Fungal Spores in Water and on Seeds by Ozone and Arc Discharge Plasma
Kang, Min Ho; Pengkit, Anchalee; Choi, Kihong; Jeon, Seong Sil; Choi, Hyo Won; Shin, Dong Bum; Choi, Eun Ha; Uhm, Han Sup; Park, Gyungsoon
2015-01-01
Seed sterilization is essential for preventing seed borne fungal diseases. Sterilization tools based on physical technologies have recently received much attention. However, available information is very limited in terms of efficiency, safety, and mode of action. In this study, we have examined antifungal activity of ozone and arc discharge plasma, potential tools for seed sterilization. In our results, ozone and arc discharge plasma have shown differential antifungal effects, depending on the environment associated with fungal spores (freely submerged in water or infected seeds). Ozone inactivates Fusarium fujikuroi (fungus causing rice bakanae disease) spores submerged in water more efficiently than arc discharge plasma. However, fungal spores associated with or infecting rice seeds are more effectively deactivated by arc discharge plasma. ROS generated in water by ozone may function as a powerful fungicidal factor. On the other hand, shockwave generated from arc discharge plasma may have greatly contributed to antifungal effects on fungus associated with rice seeds. In support of this notion, addition of ultrasonic wave in ozone generating water has greatly increased the efficiency of seed disinfection. PMID:26406468
Genetically Encoded Catalytic Hairpin Assembly for Sensitive RNA Imaging in Live Cells.
Mudiyanselage, Aruni P K K Karunanayake; Yu, Qikun; Leon-Duque, Mark A; Zhao, Bin; Wu, Rigumula; You, Mingxu
2018-06-26
DNA and RNA nanotechnology has been used for the development of dynamic molecular devices. In particular, programmable enzyme-free nucleic acid circuits, such as catalytic hairpin assembly, have been demonstrated as useful tools for bioanalysis and to scale up system complexity to an extent beyond current cellular genetic circuits. However, the intracellular functions of most synthetic nucleic acid circuits have been hindered by challenges in the biological delivery and degradation. On the other hand, genetically encoded and transcribed RNA circuits emerge as alternative powerful tools for long-term embedded cellular analysis and regulation. Herein, we reported a genetically encoded RNA-based catalytic hairpin assembly circuit for sensitive RNA imaging inside living cells. The split version of Broccoli, a fluorogenic RNA aptamer, was used as the reporter. One target RNA can catalytically trigger the fluorescence from tens-to-hundreds of Broccoli. As a result, target RNAs can be sensitively detected. We have further engineered our circuit to allow easy programming to image various target RNA sequences. This design principle opens the arena for developing a large variety of genetically encoded RNA circuits for cellular applications.
Respiratory mechanics to understand ARDS and guide mechanical ventilation.
Mauri, Tommaso; Lazzeri, Marta; Bellani, Giacomo; Zanella, Alberto; Grasselli, Giacomo
2017-11-30
As precision medicine is becoming a standard of care in selecting tailored rather than average treatments, physiological measurements might represent the first step in applying personalized therapy in the intensive care unit (ICU). A systematic assessment of respiratory mechanics in patients with the acute respiratory distress syndrome (ARDS) could represent a step in this direction, for two main reasons. Approach and Main results: On the one hand, respiratory mechanics are a powerful physiological method to understand the severity of this syndrome in each single patient. Decreased respiratory system compliance, for example, is associated with low end expiratory lung volume and more severe lung injury. On the other hand, respiratory mechanics might guide protective mechanical ventilation settings. Improved gravitationally dependent regional lung compliance could support the selection of positive end-expiratory pressure and maximize alveolar recruitment. Moreover, the association between driving airway pressure and mortality in ARDS patients potentially underlines the importance of sizing tidal volume on respiratory system compliance rather than on predicted body weight. The present review article aims to describe the main alterations of respiratory mechanics in ARDS as a potent bedside tool to understand severity and guide mechanical ventilation settings, thus representing a readily available clinical resource for ICU physicians.
Slater, James; Rill, Velisar
2004-04-01
Coronary artery disease (CAD) is the leading cause of morbidity and mortality in the United States and other industrialized countries. In the undeveloped world a similar epidemic is brewing. A new pathophysiologic paradigm has emerged, which assigns the mediators of inflammation a much larger role in the disease process. This paradigm has helped explain the unpredictable nature of many adverse consequences of CAD. The long latent phase of the disease, and often sudden initial presentation, make efforts at early detection extremely important. Considerable work has been devoted to identify, as well as influence, predisposing risk factors for developing arteriosclerosis. Novel markers of inflammation, like C-reactive protein, have been identified and compared to traditional risk factors. In addition, new imaging modalities introduce the possibility of screening for subclinical disease. Electron beam and multidetector computed tomography (CT) scanners, as well as other techniques, are emerging as powerful tools to detect early disease presence and allow intervention to take place before major clinical events occur. Advances in our understanding of the pathophysiology of CAD, and our ability to image the stages of silent disease will go hand in hand to revolutionize our approach to prevention and treatment of this deadly malady.
Slater, James; Rill, Velisar
2003-04-01
Coronary artery disease (CAD) is the leading cause of morbidity and mortality in the United States and industrialized countries. In the undeveloped world a similar epidemic is brewing. A new pathophysiologic paradigm has emerged, which assigns the mediators of inflammation a much larger role in the disease process. This paradigm has helped explain the unpredictable nature of many adverse consequences of CAD. The long latent phase of the disease and often sudden initial presentation make efforts at early detection extremely important. Considerable work has been devoted to identify as well as influence predisposing risk factors for developing arteriosclerosis. Novel markers of inflammation, like C-reactive protein, have been identified and compared to traditional risk factors. In addition, new imaging modalities introduce the possibility of screening for sub-clinical disease. Electron-beam and spiral CT scanners, as well as other techniques, are emerging as powerful tools to detect early disease presence and allow intervention to take place before major clinical events occur. Advances in our understanding of the pathophysiology and our ability to image the stages of silent disease will go hand in hand to revolutionize our approach to prevention and treatment of this deadly disease.
Hernandez-Castro, Luis E; Paterno, Marta; Villacís, Anita G; Andersson, Björn; Costales, Jaime A; De Noia, Michele; Ocaña-Mayorga, Sofía; Yumiseva, Cesar A; Grijalva, Mario J; Llewellyn, Martin S
2017-07-01
Rhodnius ecuadoriensis is the main triatomine vector of Chagas disease, American trypanosomiasis, in Southern Ecuador and Northern Peru. Genomic approaches and next generation sequencing technologies have become powerful tools for investigating population diversity and structure which is a key consideration for vector control. Here we assess the effectiveness of three different 2b restriction site-associated DNA (2b-RAD) genotyping strategies in R. ecuadoriensis to provide sufficient genomic resolution to tease apart microevolutionary processes and undertake some pilot population genomic analyses. The 2b-RAD protocol was carried out in-house at a non-specialized laboratory using 20 R. ecuadoriensis adults collected from the central coast and southern Andean region of Ecuador, from June 2006 to July 2013. 2b-RAD sequencing data was performed on an Illumina MiSeq instrument and analyzed with the STACKS de novo pipeline for loci assembly and Single Nucleotide Polymorphism (SNP) discovery. Preliminary population genomic analyses (global AMOVA and Bayesian clustering) were implemented. Our results showed that the 2b-RAD genotyping protocol is effective for R. ecuadoriensis and likely for other triatomine species. However, only BcgI and CspCI restriction enzymes provided a number of markers suitable for population genomic analysis at the read depth we generated. Our preliminary genomic analyses detected a signal of genetic structuring across the study area. Our findings suggest that 2b-RAD genotyping is both a cost effective and methodologically simple approach for generating high resolution genomic data for Chagas disease vectors with the power to distinguish between different vector populations at epidemiologically relevant scales. As such, 2b-RAD represents a powerful tool in the hands of medical entomologists with limited access to specialized molecular biological equipment.
Villacís, Anita G.; Andersson, Björn; Costales, Jaime A.; De Noia, Michele; Ocaña-Mayorga, Sofía; Yumiseva, Cesar A.; Grijalva, Mario J.; Llewellyn, Martin S.
2017-01-01
Background Rhodnius ecuadoriensis is the main triatomine vector of Chagas disease, American trypanosomiasis, in Southern Ecuador and Northern Peru. Genomic approaches and next generation sequencing technologies have become powerful tools for investigating population diversity and structure which is a key consideration for vector control. Here we assess the effectiveness of three different 2b restriction site-associated DNA (2b-RAD) genotyping strategies in R. ecuadoriensis to provide sufficient genomic resolution to tease apart microevolutionary processes and undertake some pilot population genomic analyses. Methodology/Principal findings The 2b-RAD protocol was carried out in-house at a non-specialized laboratory using 20 R. ecuadoriensis adults collected from the central coast and southern Andean region of Ecuador, from June 2006 to July 2013. 2b-RAD sequencing data was performed on an Illumina MiSeq instrument and analyzed with the STACKS de novo pipeline for loci assembly and Single Nucleotide Polymorphism (SNP) discovery. Preliminary population genomic analyses (global AMOVA and Bayesian clustering) were implemented. Our results showed that the 2b-RAD genotyping protocol is effective for R. ecuadoriensis and likely for other triatomine species. However, only BcgI and CspCI restriction enzymes provided a number of markers suitable for population genomic analysis at the read depth we generated. Our preliminary genomic analyses detected a signal of genetic structuring across the study area. Conclusions/Significance Our findings suggest that 2b-RAD genotyping is both a cost effective and methodologically simple approach for generating high resolution genomic data for Chagas disease vectors with the power to distinguish between different vector populations at epidemiologically relevant scales. As such, 2b-RAD represents a powerful tool in the hands of medical entomologists with limited access to specialized molecular biological equipment. PMID:28723901
Design of a water-powered DTH hammer for deep drilling application
NASA Astrophysics Data System (ADS)
Cho, Min Jae; Kim, Donguk; Oh, Joo Young; Yook, Se-Jin; Kim, Young Won
2017-11-01
A DTH (Down-the-hole) hammer powered by highly pressurized fluid is a drilling tool using the motion of percussion of a drill bit. In retrospect, a DTH by using compressed air as a power source has been widely used in drilling industries such as applications of mining, geothermal etc. On the other hand, another type of a DTH that uses pressurized water, called a water hammer, has recently seen deep drilling applications, while it has been rarely investigated. In this study, we designed a water-powered DTH hammer which mainly consists of several components such as a piston, a poppet valve, a cap and a bit for deep drilling applications. We optimized the components of the hammer on the basis of the results of 1D analysis using commercial software of AMESIM. An experimental study has been also conducted to investigate a performance of the designed water hammer. We measured a pressure distribution inside the hammer system as a function of time, and it thus estimates a frequency of impaction of the bit, which has been also analyzed in frequency domain. In addition, some important parameters have been discussed in conjunction with a limitation of impaction frequency as input pressure. We believe that this study provides design rules of a water-based DTH for deep drilling applications. This work is supported by KITECH of Korean government.
Wilson, Mark; McGrath, John; Vine, Samuel; Brewer, James; Defriend, David; Masters, Richard
2010-10-01
Surgical simulation is increasingly used to facilitate the adoption of technical skills during surgical training. This study sought to determine if gaze control parameters could differentiate between the visual control of experienced and novice operators performing an eye-hand coordination task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Typically adopted hand movement metrics reflect only one half of the eye-hand coordination relationship; therefore, little is known about how hand movements are guided and controlled by vision. A total of 14 right-handed surgeons were categorised as being either experienced (having led more than 70 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The eight experienced and six novice surgeons completed the eye-hand coordination task from the LAP Mentor basic skills package while wearing a gaze registration system. A variety of performance, movement, and gaze parameters were recorded and compared between groups. The experienced surgeons completed the task significantly more quickly than the novices, but only the economy of movement of the left tool differentiated skill level from the LAP Mentor parameters. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. The findings of the study provide support for the utility of assessing strategic gaze behaviour to better understand the way in which surgeons utilise visual information to plan and control tool movements in a virtual reality laparoscopic environment. It is hoped that by better understanding the limitations of the psychomotor system, effective gaze training programs may be developed.
McGrath, John; Vine, Samuel; Brewer, James; Defriend, David; Masters, Richard
2010-01-01
Background Surgical simulation is increasingly used to facilitate the adoption of technical skills during surgical training. This study sought to determine if gaze control parameters could differentiate between the visual control of experienced and novice operators performing an eye-hand coordination task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Typically adopted hand movement metrics reflect only one half of the eye-hand coordination relationship; therefore, little is known about how hand movements are guided and controlled by vision. Methods A total of 14 right-handed surgeons were categorised as being either experienced (having led more than 70 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The eight experienced and six novice surgeons completed the eye-hand coordination task from the LAP Mentor basic skills package while wearing a gaze registration system. A variety of performance, movement, and gaze parameters were recorded and compared between groups. Results The experienced surgeons completed the task significantly more quickly than the novices, but only the economy of movement of the left tool differentiated skill level from the LAP Mentor parameters. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. Conclusion The findings of the study provide support for the utility of assessing strategic gaze behaviour to better understand the way in which surgeons utilise visual information to plan and control tool movements in a virtual reality laparoscopic environment. It is hoped that by better understanding the limitations of the psychomotor system, effective gaze training programs may be developed. PMID:20333405
Srigley, J A; Corace, K; Hargadon, D P; Yu, D; MacDonald, T; Fabrigar, L; Garber, G
2015-11-01
Despite the importance of hand hygiene in preventing transmission of healthcare-associated infections, compliance rates are suboptimal. Hand hygiene is a complex behaviour and psychological frameworks are promising tools to influence healthcare worker (HCW) behaviour. (i) To review the effectiveness of interventions based on psychological theories of behaviour change to improve HCW hand hygiene compliance; (ii) to determine which frameworks have been used to predict HCW hand hygiene compliance. Multiple databases and reference lists of included studies were searched for studies that applied psychological theories to improve and/or predict HCW hand hygiene. All steps in selection, data extraction, and quality assessment were performed independently by two reviewers. The search yielded 918 citations; seven met eligibility criteria. Four studies evaluated hand hygiene interventions based on psychological frameworks. Interventions were informed by goal setting, control theory, operant learning, positive reinforcement, change theory, the theory of planned behaviour, and the transtheoretical model. Three predictive studies employed the theory of planned behaviour, the transtheoretical model, and the theoretical domains framework. Interventions to improve hand hygiene adherence demonstrated efficacy but studies were at moderate to high risk of bias. For many studies, it was unclear how theories of behaviour change were used to inform the interventions. Predictive studies had mixed results. Behaviour change theory is a promising tool for improving hand hygiene; however, these theories have not been extensively examined. Our review reveals a significant gap in the literature and indicates possible avenues for novel research. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Drawings of the Modular Equipment Transporter and Hand Tool Carrier
1970-10-12
S70-50762 (November 1970) --- A line drawing illustrating layout view of the modular equipment transporter (MET) and its equipment. A MET (or Rickshaw, as it has been nicknamed) will be used on the lunar surface for the first time during the Apollo 14 lunar landing mission. The Rickshaw will serve as a portable workbench with a place for the Apollo lunar hand tools (ALHT) and their carrier, three cameras, two sample container bags, a special environment sample container (SESC), a lunar portable magnetometer (LPM) and spare film magazines.
SMART micro-scissors with dual motors and OCT sensors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Yeo, Chaebeom; Jang, Seonjin; Park, Hyun-cheol; Gehlbach, Peter L.; Song, Cheol
2017-02-01
Various end-effectors of microsurgical instruments have been developed and studied. Also, many approaches to stabilize the tool-tip using robotics have been studied such as the steady hand robot system, Micron, and SMART system. In our previous study, the horizontal SMART micro-scissors with a common path swept source OCT distance and one linear piezoelectric (PZT) motor was demonstrated as a microsurgical system. Because the outer needle is connected with a mechanical handle and moved to engage the tool tip manually, the tool tip position is instantaneously changed during the engaging. The undesirable motion can make unexpected tissue damages and low surgical accuracy. In this study, we suggest a prototype horizontal SMART micro-scissors which has dual OCT sensors and two motors to improve the tremor cancellation. Dual OCT sensors provide two distance information. Front OCT sensor detects a distance from the sample surface to the tool tip. Rear OCT sensors gives current PZT motor movement, acting like a motor encoder. The PZT motor can compensate the hand tremor with a feedback loop control. The manual engaging of tool tip in previous SMART system is replaced by electrical engaging using a squiggle motor. Compared with previous study, this study showed better performance in the hand tremor reduction. From the result, the SMART with automatic engaging may become increasingly valuable in microsurgical instruments.
Development of Asset Management Decision Support Tools for Power Equipment
NASA Astrophysics Data System (ADS)
Okamoto, Tatsuki; Takahashi, Tsuguhiro
Development of asset management decision support tools become very intensive in order to reduce maintenance cost of power equipment due to the liberalization of power business. This article reviews some aspects of present status of asset management decision support tools development for power equipment based on the papers published in international conferences, domestic conventions, and several journals.
When does tool use become distinctively human?: Hammering in young children
Kahrs, Björn; Lockman, Jeffrey J.; Jung, Wendy
2013-01-01
This study examines the development of hammering within an ontogenetic and evolutionary framework using motion-capture technology. Twenty-four right-handed toddlers (19–35 months) wore reflective markers while hammering a peg into a peg-board. The study focuses on the motor characteristics that make tool use uniquely human: wrist involvement, lateralization, and handle use. Older children showed more distally controlled movements, characterized by relatively more reliance on the wrist, but only when hammering with their right hand. Greater age, use of the right hand, and more wrist involvement were associated with higher accuracy; handle use did not systematically change with age. Collectively, the results provide new insights about the emergence of hammering in young children and when hammering begins to manifest distinctively human characteristics. PMID:24128178
About the Managing and Transforming Waste Streams Tool
The Managing and Transforming Waste Streams Tool was developed by a team of zero waste consultants and solid waste program managers making informed observations from hands-on work in communities, with contributions from EPA.
Muhumuza, Christine; Gomersall, Judith Streak; Fredrick, Makumbi E; Atuyambe, Lynn; Okiira, Christopher; Mukose, Aggrey; Ssempebwa, John
2015-03-01
The hands of a health care worker are a common vehicle of pathogen transmission in hospital settings. Health care worker hand hygiene is therefore critical for patients' well being. Whilst failure of health care workers to comply with the best hand hygiene practice is a problem in all health care settings, issues of lack of access to adequate cleaning equipment and in some cases even running water make practicing good hand hygiene particularly difficult in low-resource developing country settings. This study reports an audit and feedback project that focused on the hand hygiene of the health care worker in the pediatric special care unit of the Mulago National Referral Hospital, which is a low-resource setting in Uganda. To improve hand hygiene among health care workers in the pediatric special care unit and thereby contribute to reducing transmission of health care worker-associated pathogens. The Joanna Briggs Institute three-phase Practical Application of Clinical Evidence System audit and feedback tool for promoting evidence utilization and change in health care was used. In phase one of the project, stakeholders were engaged and seven evidence-based audit criteria were developed. A baseline audit was then conducted. In phase two, barriers underpinning areas of noncompliance found in the baseline audit were identified and three strategies - education, reminders and provision of hand cleaning equipment - were implemented to overcome them. In phase three, a follow-up audit was conducted. Compliance with best practice hygiene was found to be poor in the baseline audit for all but one of the audit criteria. Following the implementation of the strategies, hand hygiene improved. The compliance rate increased substantially across all criteria. Staff education achieved 100%, whilst criterion 4 increased to 70%. However, use of alcohol-based hand-rub for hand hygiene only improved to 66%, and for six of the seven audit criteria, compliance remained below 74%. The project provides another example of how audit can be used as a tool to improve health practice, even in a low-resource setting. At the same time, it showed how difficult it is to achieve compliance with best hand hygiene practice in a low-resource hospital. The project highlights the importance of continued education/awareness raising on the importance of good hand hygiene practice as well as investment in infrastructure and cleaning supplies for achieving and sustaining good hand hygiene among workers in a low-resource hospital setting. A key contribution of the project was the legacy it left in the form of knowledge about how to use audit and feedback as a tool to promote the best practice. A similar project has been implemented in the maternity ward at the hospital and further audits are planned.