Sample records for practical detection limit

  1. Automated detection of diabetic retinopathy: barriers to translation into clinical practice.

    PubMed

    Abramoff, Michael D; Niemeijer, Meindert; Russell, Stephen R

    2010-03-01

    Automated identification of diabetic retinopathy (DR), the primary cause of blindness and visual loss for those aged 18-65 years, from color images of the retina has enormous potential to increase the quality, cost-effectiveness and accessibility of preventative care for people with diabetes. Through advanced image analysis techniques, retinal images are analyzed for abnormalities that define and correlate with the severity of DR. Translating automated DR detection into clinical practice will require surmounting scientific and nonscientific barriers. Scientific concerns, such as DR detection limits compared with human experts, can be studied and measured. Ethical, legal and political issues can be addressed, but are difficult or impossible to measure. The primary objective of this review is to survey the methods, potential benefits and limitations of automated detection in order to better manage translation into clinical practice, based on extensive experience with the systems we have developed.

  2. Comparison of detection limits in environmental analysis--is it possible? An approach on quality assurance in the lower working range by verification.

    PubMed

    Geiss, S; Einax, J W

    2001-07-01

    Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.

  3. 40 CFR 63.1453 - How do I demonstrate continuous compliance with the emission limitations, work practice standards...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... percent opacity. (c) Baghouses. For each baghouse subject to the operating limit for the bag leak... that the bag leak detection system alarm does not sound for more than 5 percent of the operating time... malfunction of the bag leak detection system are not included in the calculation. (ii) Alarms that occur...

  4. Characterizing bio-optical and ecological features of algal bloom waters for detection and tracking from space

    NASA Astrophysics Data System (ADS)

    Ahmed, S.; Amin, R.; Gladkova, I.; Gilerson, A.; Grossberg, M.; Hlaing, S.; Shariar, F.; Alabi, P.

    2010-04-01

    The detection and monitoring of harmful algal blooms using in-situ field measurements is both labor intensive and is practically limited on achievable temporal and spatial resolutions, since field measurements are typically carried out at a series of discrete points and at discrete times, with practical limitations on temporal continuity. The planning and preparation of remedial measures to reduce health risks, etc., requires detection approaches which can effectively cover larger areas with contiguous spatial resolutions, and at the same time offer a more comprehensive and contemporaneous snapshot of entire blooms as they occur. This is beyond capabilities of in-situ measurements and it is in this context that satellite Ocean Color sensors offer potential advantages for bloom detection and monitoring. In this paper we examine the applications and limitations of an approach we have recently developed for the detection of K. brevis blooms from satellite Ocean Color Sensors measurements, the Red Band Difference Technique, and compare it to other detection algorithm approaches, including a new statistical based approach also proposed here. To achieve more uniform standards of comparisons, the performance of different techniques for detection are applied to the same specific verified blooms occurring off the West Florida Shelf (WFS) that have been verified by in-situ measurements.

  5. Reaching quantum limits for phase-shift detection with semiclassical states

    NASA Astrophysics Data System (ADS)

    Luis, Alfredo

    2004-01-01

    We present two measuring strategies reaching the Heisenberg limit for phase-shift measurements using semiclassical coherent states exclusively. We examine their performance by assuming practical experimental conditions such as losses and nonideal detectors.

  6. Fundamentals of Counting Statistics in Digital PCR: I Just Measured Two Target Copies-What Does It Mean?

    PubMed

    Tzonev, Svilen

    2018-01-01

    Current commercially available digital PCR (dPCR) systems and assays are capable of detecting individual target molecules with considerable reliability. As tests are developed and validated for use on clinical samples, the need to understand and develop robust statistical analysis routines increases. This chapter covers the fundamental processes and limitations of detecting and reporting on single molecule detection. We cover the basics of quantification of targets and sources of imprecision. We describe the basic test concepts: sensitivity, specificity, limit of blank, limit of detection, and limit of quantification in the context of dPCR. We provide basic guidelines how to determine those, how to choose and interpret the operating point, and what factors may influence overall test performance in practice.

  7. Heisenberg limit for displacements with semiclassical states

    NASA Astrophysics Data System (ADS)

    Luis, Alfredo

    2004-04-01

    We analyze the quantum limit to the sensitivity of the detection of small displacements. We focus on the case of free particles and harmonic oscillators as the systems experiencing the displacement. We show that the minimum displacement detectable is proportional to the inverse of the square root of the mean value of the energy in the state experiencing the displacement (Heisenberg limit). We present a measuring scheme that reaches this limit using semiclassical states. We examine the performance of this strategy under realistic practical conditions by computing the effect of imperfections such as losses and nonunit detection efficiencies. This analysis confirms the robustness of this measuring strategy by showing that the experimental imperfections can be suitably compensated by increasing the mean energy of the input state.

  8. Security breaches: tips for assessing and limiting your risks.

    PubMed

    Coons, Leeanne R

    2011-01-01

    As part of their compliance planning, medical practices should undergo a risk assessment to determine any vulnerability within the practice relative to security breaches. Practices should also implement safeguards to limit their risks. Such safeguards include facility access controls, information and electronic media management, use of business associate agreements, and education and enforcement. Implementation of specific policies and procedures to address security incidents is another critical step that medical practices should take as part of their security incident prevention plan. Medical practices should not only develop policies and procedures to prevent, detect, contain, and correct security violations, but should make sure that such policies and procedures are actually implemented in their everyday operations.

  9. AOTF hyperspectral microscope imaging for foodborne bacteria detection

    USDA-ARS?s Scientific Manuscript database

    Food safety is an important public health issue worldwide. Researchers have developed many different methods for detecting foodborne pathogens; however, most technologies currently being used have limitations, in terms of speed, sensitivity and selectivity, for practical use in the food industry. Ac...

  10. Addressing the Limit of Detectability of Residual Oxide Discontinuities in Friction Stir Butt Welds of Aluminum using Phased Array Ultrasound

    NASA Technical Reports Server (NTRS)

    Johnston, P. H.

    2008-01-01

    This activity seeks to estimate a theoretical upper bound of detectability for a layer of oxide embedded in a friction stir weld in aluminum. The oxide is theoretically modeled as an ideal planar layer of aluminum oxide, oriented normal to an interrogating ultrasound beam. Experimentally-measured grain scattering level is used to represent the practical noise floor. Echoes from naturally-occurring oxides will necessarily fall below this theoretical limit, and must be above the measurement noise to be potentially detectable.

  11. Establishing generic remediation goals for the polycyclic aromatic hydrocarbons: critical issues.

    PubMed Central

    LaGoy, P K; Quirk, T C

    1994-01-01

    Polycyclic aromatic hydrocarbons (PAHs) were one of the first classes of compounds identified as carcinogens and are often chemicals of concern at hazardous waste sites. Remediation goals established by regulatory agencies for carcinogenic PAHs in soil are generally either risk based or based on the method detection limits. PAHs are products of incomplete combustion, are components of petroleum, and as such, are prevalent in the environment from both natural and anthropogenic sources. Background concentrations are often above risk- or detection limit-based criteria, and therefore these remediation goals are of limited practical use as target criteria. In addition, the approaches used to establish target criteria do not account for several factors that may produce over- or underestimates of risk associated with the PAHs. Because of the frequency with which these compounds are detected, it is imperative that reasonably achievable and practical remediation goals be established. This paper examines the various factors that contribute to over- and underestimates of risks associated with PAHs and presents an approach for establishing cleanup criteria that takes into account health risks, background concentrations, and achievability. Images p348-a PMID:7925174

  12. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.

    PubMed

    Ball, M J; Robertson, I K; Woods, M

    1994-11-01

    Comparison of cholesterol determinations by nurses using a Reflotron analyser in a general practice setting showed a good correlation with plasma cholesterol determinations by wet chemistry in a clinical biochemistry laboratory. A limited number of comparisons did, however, give a much lower result on the Reflotron. In an experimental situation, small sample volumes (which could result from poor technique) were shown to produce falsely low readings. A simple method which may immediately detect falsely low Reflotron readings is discussed.

  13. Enhanced Detectability of Community Structure in Multilayer Networks through Layer Aggregation.

    PubMed

    Taylor, Dane; Shai, Saray; Stanley, Natalie; Mucha, Peter J

    2016-06-03

    Many systems are naturally represented by a multilayer network in which edges exist in multiple layers that encode different, but potentially related, types of interactions, and it is important to understand limitations on the detectability of community structure in these networks. Using random matrix theory, we analyze detectability limitations for multilayer (specifically, multiplex) stochastic block models (SBMs) in which L layers are derived from a common SBM. We study the effect of layer aggregation on detectability for several aggregation methods, including summation of the layers' adjacency matrices for which we show the detectability limit vanishes as O(L^{-1/2}) with increasing number of layers, L. Importantly, we find a similar scaling behavior when the summation is thresholded at an optimal value, providing insight into the common-but not well understood-practice of thresholding pairwise-interaction data to obtain sparse network representations.

  14. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    PubMed

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  15. Censoring approach to the detection limits in X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Pajek, M.; Kubala-Kukuś, A.

    2004-10-01

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called "nondetects", can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples.

  16. Highly selective luminescent sensing of picric acid based on a water-stable europium metal-organic framework

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Tifeng; Zhu, Fengliang; Cui, Yuanjing, E-mail: cuiyj@zju.edu.cn

    A water-stable metal-organic framework (MOF) EuNDC has been synthesized for selective detection of the well-known contaminant and toxicant picric acid (PA) in aqueous solution. Due to the photo-induced electron transfer and self-absorption mechanism, EuNDC displayed rapid, selective and sensitive detection of PA with a detection limit of 37.6 ppb. Recyclability experiments revealed that EuNDC retains its initial luminescent intensity and same quenching efficiency in each cycle, suggesting high photostability and reusability for long-term sensing applications. The excellent detection performance of EuNDC makes it a promising PA sensing material for practical applications. - Graphical abstract: A water-stable europium-based metal-organic framework hasmore » been reported for highly selective sensing of picric acid (PA) with a detection limit of 37.6 ppb in aqueous solution. - Highlights: • A water-stable metal-organic framework (MOF) EuNDC was synthesized. • The highly selective detection of picric acid with a detection limit of 37.6 ppb was realized. • The detection mechanism were also presented and discussed.« less

  17. Utility of the Mantel-Haenszel Procedure for Detecting Differential Item Functioning in Small Samples

    ERIC Educational Resources Information Center

    Fidalgo, Angel M.; Ferreres, Doris; Muniz, Jose

    2004-01-01

    Sample-size restrictions limit the contingency table approaches based on asymptotic distributions, such as the Mantel-Haenszel (MH) procedure, for detecting differential item functioning (DIF) in many practical applications. Within this framework, the present study investigated the power and Type I error performance of empirical and inferential…

  18. A microcantilever-based silver ion sensor using DNA-functionalized gold nanoparticles as a mass amplifier

    NASA Astrophysics Data System (ADS)

    You, Juneseok; Song, Yeongjin; Park, Chanho; Jang, Kuewhan; Na, Sungsoo

    2017-06-01

    Silver ions have been used to sterilize many products, however, it has recently been demonstrated that silver ions can be toxic. This toxicity has been studied over many years with the lethal concentration at 10 μM. Silver ions can accumulate through the food chain, causing serious health problems in many species. Hence, there is a need for a commercially available silver ion sensor, with high detection sensitivity. In this work, we develop an ultra-sensitive silver ion sensor platform, using cytosine based DNA and gold nanoparticles as the mass amplifier. We achieve a lower detection limit for silver ions of 10 pM; this detection limit is one million times lower than the toxic concentration. Using our sensor platform we examine highly selective characteristics of other typical ions in water from natural sources. Furthermore, our sensor platform is able to detect silver ions in a real practical sample of commercially available drinking water. Our sensor platform, which we have termed a ‘MAIS’ (mass amplifier ion sensor), with a simple detection procedure, high sensitivity, selectivity and real practical applicability has shown potential as an early toxicity assessment of silver ions in the environment.

  19. Estimating the resolution limit of the map equation in community detection

    NASA Astrophysics Data System (ADS)

    Kawamoto, Tatsuro; Rosvall, Martin

    2015-01-01

    A community detection algorithm is considered to have a resolution limit if the scale of the smallest modules that can be resolved depends on the size of the analyzed subnetwork. The resolution limit is known to prevent some community detection algorithms from accurately identifying the modular structure of a network. In fact, any global objective function for measuring the quality of a two-level assignment of nodes into modules must have some sort of resolution limit or an external resolution parameter. However, it is yet unknown how the resolution limit affects the so-called map equation, which is known to be an efficient objective function for community detection. We derive an analytical estimate and conclude that the resolution limit of the map equation is set by the total number of links between modules instead of the total number of links in the full network as for modularity. This mechanism makes the resolution limit much less restrictive for the map equation than for modularity; in practice, it is orders of magnitudes smaller. Furthermore, we argue that the effect of the resolution limit often results from shoehorning multilevel modular structures into two-level descriptions. As we show, the hierarchical map equation effectively eliminates the resolution limit for networks with nested multilevel modular structures.

  20. Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

    PubMed

    Cody, R B; Tamura, J; Finch, J W; Musselman, B D

    1994-03-01

    Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2∶1 for a 500 amol/μL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/μL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.

  1. Deception Detection in a Computer-Mediated Environment: Gender, Trust, and Training Issues

    DTIC Science & Technology

    2003-03-01

    to the understanding of deception detection from both a practical and academic point of view. The lessons learned from the limitations of this...has truly been a learning experience and a great capstone to a challenging Master’s program. I also owe great appreciation to individuals that...83 Academic Implications and Suggestions

  2. Cutaneous T cell lymphoma: Current practices in blood assessment and the utility of T-cell receptor Vβ chain restriction

    PubMed Central

    Gibson, Juliet F; Huang, Jing; Liu, Kristina J; Carlson, Kacie R; Foss, Francine; Choi, Jaehyuk; Edelson, Richard; Hussong, Jerry W.; Mohl, Ramsey; Hill, Sally; Girardi, Sally

    2016-01-01

    Background Accurate quantification of malignant cells in the peripheral blood of patients with cutaneous T cell lymphoma (CTCL) is important for early detection, prognosis, and monitoring disease burden. Objective Determine the spectrum of current clinical practices; critically evaluate elements of current ISCL B1 and B2 staging criteria; and assess the potential role of TCR-Vβ analysis by flow cytometry. Methods We assessed current clinical practices by survey, and performed a retrospective analysis of 161 patients evaluated at Yale (2011-2014) to compare the sensitivity, specificity, PPV, and NPV of parameters for ISCL B2 staging. Results There was heterogeneity in clinical practices among institutions. ISCL B1 criteria did not capture five Yale cohort patients with immunophenotypic abnormalities who later progressed. TCR-Vβ testing was more specific than PCR and aided diagnosis in detecting clonality, but was of limited benefit in quantification of tumor burden. Limitations Because of limited follow-up involving a single center, further investigation will be necessary to conclude whether our proposed diagnostic algorithm is of general clinical benefit. Conclusion We propose further study of “modified B1 criteria”: CD4/CD8 ratio ≥5, %CD4+/CD26- ≥ 20%, %CD4+/CD7- ≥ 20%, with evidence of clonality. TCR-Vβ testing should be considered in future diagnostic and staging algorithms. PMID:26874819

  3. Improving colorectal cancer screening: fact and fantasy

    NASA Astrophysics Data System (ADS)

    Van Dam, Jacques

    2008-02-01

    Premalignant diseases of the gastrointestinal tract, such as Barrett's esophagus, long-standing ulcerative colitis, and adenomatous polyps, have a significantly increased risk for development of adenocarcinoma, most often through an intermediate stage of dysplasia. Adenocarcinoma of the colon is the second most common cancer in the United States. Because patients with colorectal cancer often present with advanced disease, the outcomes are associated with significant morbidity and mortality. Effective methods of early detection are essential. As non-polypoid dysplasia is not visible using conventional endoscopy, surveillance of patients with Barrett's esophagus and ulcerative colitis is performed via a system in which multiple random biopsies are obtained at prescribed intervals. Sampling error and missed diagnoses occur frequently and render current screening methods inadequate. Also, the examination of a tissue biopsy is time consuming and costly, and significant intra- and inter-observer variation may occur. The newer methods discussed herein demonstrate the potential to solve these problems by early detection of disease with high sensitivity and specificity. Conventional endoscopy is based on the observation of white light reflected off the tissue surface. Subtle changes in color and shadow reveal structural changes. New developments in optical imaging go beyond white light, exploiting other properties of light. Several promising methods will be discussed at this meeting and shall be briefly discussed below. However, few such imaging modalities have arrived at our clinical practice. Some much more practical methods to improve colorectal cancer screening are currently being evaluated for their clinical impact. These methods seek to overcome limitations other than those of detecting dysplasia not visible under white light endoscopy. The current standard practice of colorectal cancer screening utilizes colonoscopy, an uncomfortable, sometimes difficult medical procedure. Efforts to improve the practice of colonoscopy will be described. Another limitation of the current practice is the inability to detect polypoid neoplasia that is hidden from view under white light imaging by the natural folds that occur within the colon. A device to overcome this limitation will also be described. Efforts to improve colorectal cancer screening (and thereby decrease the death rate of this second leading cause of cancer death in the United States) are progressing in many arenas. The researcher, basic or clinical, should maintain an up to date overview of the field and how each new technological advance is likely to have a role in the screening and early detection of colorectal cancer.

  4. Long-term implications of observing an expanding cosmological civilization

    NASA Astrophysics Data System (ADS)

    Olson, S. Jay

    2018-01-01

    Suppose that advanced civilizations, separated by a cosmological distance and time, wish to maximize their access to cosmic resources by rapidly expanding into the universe. How does the presence of one limit the expansionistic ambitions of another, and what sort of boundary forms between their expanding domains? We describe a general scenario for any expansion speed, separation distance and time. We then specialize to a question of particular interest: What are the future prospects for a young and ambitious civilization if they can observe the presence of another at a cosmological distance? We treat cases involving the observation of one or two expanding domains. In the single-observation case, we find that almost any plausible detection will limit one's future cosmic expansion to some extent. Also, practical technological limits to expansion speed (well below the speed of light) play an interesting role. If a domain is visible at the time one embarks on cosmic expansion, higher practical limits to expansion speed are beneficial only up to a certain point. Beyond this point, a higher speed limit means that gains in the ability to expand are more than offset by the first-mover advantage of the observed domain. In the case of two visible domains, it is possible to be `trapped' by them if the practical speed limit is high enough and their angular separation in the sky is large enough, i.e. one's expansion in any direction will terminate at a boundary with the two visible civilizations. Detection at an extreme cosmological distance has surprisingly little mitigating effect on our conclusions.

  5. 40 CFR Table 6 to Subpart Kkkkk of... - Continuous Compliance With Emission Limitations and Work Practice Standards

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... or DLS/FF i. If you use a bag leak detection system, initiating corrective action within 1 hour of a bag leak detection system alarm and completing corrective actions in accordance with your OM&M plan... established during the performance test; and iv. If chemicals are added to the scrubber water, collecting the...

  6. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    PubMed

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  7. A sensitive and selective resonance Rayleigh scattering method for quick detection of avidin using affinity labeling Au nanoparticles

    NASA Astrophysics Data System (ADS)

    Wang, Qi; Huang, Xi; Fu, Xuan; Deng, Huan; Ma, Meihu; Cai, Zhaoxia

    2016-06-01

    Avidin is a glycoprotein with antinutritional property, which should be limited in daily food. We developed an affinity biosensor system based on resonance Rayleigh scattering (RRS) and using affinity biotin labeling Au nanoparticles (AuNPs). This method was selective and sensitive for quick avidin detection due to the avidin-biotin affinitive interaction. Under optimal conditions, RRS intensity of biotin-AuNPs increase linearly with an increasing concentration of avidin from 5 to 160 ng/mL. The lower limit of detection was 0.59 ng/mL. This rapid and selective avidin detection method was used in synthetic samples and egg products with recoveries of between 102.97 and 107.92%, thereby demonstrating the feasible and practical application of this assay.

  8. Hybrid Monte Carlo/Deterministic Methods for Accelerating Active Interrogation Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peplow, Douglas E.; Miller, Thomas Martin; Patton, Bruce W

    2013-01-01

    The potential for smuggling special nuclear material (SNM) into the United States is a major concern to homeland security, so federal agencies are investigating a variety of preventive measures, including detection and interdiction of SNM during transport. One approach for SNM detection, called active interrogation, uses a radiation source, such as a beam of neutrons or photons, to scan cargo containers and detect the products of induced fissions. In realistic cargo transport scenarios, the process of inducing and detecting fissions in SNM is difficult due to the presence of various and potentially thick materials between the radiation source and themore » SNM, and the practical limitations on radiation source strength and detection capabilities. Therefore, computer simulations are being used, along with experimental measurements, in efforts to design effective active interrogation detection systems. The computer simulations mostly consist of simulating radiation transport from the source to the detector region(s). Although the Monte Carlo method is predominantly used for these simulations, difficulties persist related to calculating statistically meaningful detector responses in practical computing times, thereby limiting their usefulness for design and evaluation of practical active interrogation systems. In previous work, the benefits of hybrid methods that use the results of approximate deterministic transport calculations to accelerate high-fidelity Monte Carlo simulations have been demonstrated for source-detector type problems. In this work, the hybrid methods are applied and evaluated for three example active interrogation problems. Additionally, a new approach is presented that uses multiple goal-based importance functions depending on a particle s relevance to the ultimate goal of the simulation. Results from the examples demonstrate that the application of hybrid methods to active interrogation problems dramatically increases their calculational efficiency.« less

  9. Impact of ERTS-1 images on management of New Jersey's coastal zone

    NASA Technical Reports Server (NTRS)

    Feinberg, E. B.; Yunghans, R. S.; Stitt, J. A.; Mairs, R. L.

    1974-01-01

    The thrust of New Jersey's ERTS investigation is development of procedures for operational use of ERTS-1 data by the Department of Environmental Protection in the management of the State's coastal zone. Four major areas of concern were investigated: detection of land use changes in the coastal zone; monitoring of offshore waste disposal; siting of ocean outfalls; and allocation of funds for shore protection. ERTS imagery was not useful for shore protection purposes; it was of limited practical value in the evaluation of offshore waste disposal and ocean outfall siting. However, ERTS imagery shows great promise for operational detection of land use changes in the coastal zone. Some constraints for practical change detection have been identified.

  10. APPLICATIONS OF ELECTROCHEMICAL IMMUNOSENSORS TO ENVIRONMENTAL MONITORING

    EPA Science Inventory

    This paper discusses basic electrochemical immunoassay technology. Factors limiting the practical application of antibodies to anlaytical problems are also presented. It addresses the potential use of immunoassay methods based on electrochemical detection for the analysis of env...

  11. Industrial-hygiene characterization of ethylene oxide exposures of hospital and nursing-home workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ringenburg, V.L.; Elliott, L.J.; Morelli-Schroth, P.

    Industrial-hygiene surveys were conducted at 12 hospitals and one nursing home to determine possible employee exposure to ethylene oxide (EtO). Different types of exposure situations existed at each of the facilities as a result of various engineering controls, administrative controls and work practices. Sampling indicated that the time-weighted averages (TWAs) of exposure over periods of 36 to 724 minutes ranged from below the limit of detection to 6.7 parts per million (ppm). Personal short-term exposure levels covering 2 to 30 minutes ranged from less than the limit of detection to 103.2ppm. Factors found to be responsible for these higher-than-permissible levelsmore » of EtO exposure included improper installation or lack of engineering controls (such as improper placement of the sterilizing operations), unbalanced ventilation systems, and lack of administrative controls resulting in inappropriate work practices.« less

  12. Iron pentacarbonyl detection limits in the cigarette smoke matrix using FT-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Parrish, Milton E.; Plunkett, Susan E.; Harward, Charles N.

    2005-11-01

    Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO) 5] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide. An FT-IR puff-by-puff method was developed and the detection limit was determined using two primary reference spectra from different sources to estimate the amount of Fe(CO) 5 present in a high-pressure steel cylinder of CO. We do not detect Fe(CO) 5 in a single 35 mL puff from reference cigarettes or from those cigarette models having cigarette paper made with iron oxide, with a 30-ppbV limit of detection (LOD). Also, it was shown that a filter containing activated carbon would remove Fe(CO) 5.

  13. Binding mode dependent signaling for the detection of Cu2 +: An experimental and theoretical approach with practical applications

    NASA Astrophysics Data System (ADS)

    Ghosh, Soumen; Khan, Mehebub Ali; Ganguly, Aniruddha; Masum, Abdulla Al; Alam, Md. Akhtarul; Guchhait, Nikhil

    2018-02-01

    Two amido-schiff bases (3-Hydroxy-naphthalene-2-carboxylic acid pyren-1-ylmethylene-hydrazide and Naphthalene-2-carboxylic acid pyren-1-ylmethylene-hydrazide) have been synthesized having a common structural unit and only differs by a -OH group in the naphthalene ring. Both of them can detect Cu2 + ion selectively in semi-aqueous medium in distinctly different output modes (one detects Cu2 + by naked-eye color change where as the other detects Cu2 + by fluorescence enhancement). The difference in the binding of Cu 2 + with the compounds is the reason for this observation. The detection limit is found to be micromolar region for compound which contains -OH group whereas the compound without -OH group detects copper in nano-molar region. DFT calculations have been performed in order to demonstrate the structure of the compounds and their copper complexes. Practical utility has been explored by successful paper strip response of both the compounds. The biological applications have been evaluated in RAW 264.7.

  14. Discrepancy detection in the retrieval-enhanced suggestibility paradigm.

    PubMed

    Butler, Brendon Jerome; Loftus, Elizabeth F

    2018-04-01

    Retrieval-enhanced suggestibility (RES) refers to the finding that immediately recalling the details of a witnessed event can increase susceptibility to later misinformation. In three experiments, we sought to gain a deeper understanding of the role that retrieval plays in the RES paradigm. Consistent with past research, initial testing did increase susceptibility to misinformation - but only for those who failed to detect discrepancies between the original event and the post-event misinformation. In all three experiments, subjects who retrospectively detected discrepancies in the post-event narratives were more resistant to misinformation than those who did not. In Experiments 2 and 3, having subjects concurrently assess the consistency of the misinformation narratives negated the RES effect. Interestingly, in Experiments 2 and 3, subjects who had retrieval practice and detected discrepancies were more likely to endorse misinformation than control subjects who detected discrepancies. These results call attention to limiting conditions of the RES effect and highlight the complex relationship between retrieval practice, discrepancy detection, and misinformation endorsement.

  15. Performance limitations of label-free sensors in molecular diagnosis using complex samples

    NASA Astrophysics Data System (ADS)

    Varma, Manoj

    2016-03-01

    Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.

  16. Toward Intelligent Software Defect Detection

    NASA Technical Reports Server (NTRS)

    Benson, Markland J.

    2011-01-01

    Source code level software defect detection has gone from state of the art to a software engineering best practice. Automated code analysis tools streamline many of the aspects of formal code inspections but have the drawback of being difficult to construct and either prone to false positives or severely limited in the set of defects that can be detected. Machine learning technology provides the promise of learning software defects by example, easing construction of detectors and broadening the range of defects that can be found. Pinpointing software defects with the same level of granularity as prominent source code analysis tools distinguishes this research from past efforts, which focused on analyzing software engineering metrics data with granularity limited to that of a particular function rather than a line of code.

  17. A dual-responsive colorimetric and fluorescent chemosensor based on diketopyrrolopyrrole derivative for naked-eye detection of Fe3 + and its practical application

    NASA Astrophysics Data System (ADS)

    Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen

    2018-01-01

    A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe3 + detection was designed and synthesized. In presence of Fe3 +, sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe3 + complex was found as 2.4 × 104 with the lower detection limit of 14.3 nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1H NMR spectra. Sensor L for Fe3 + detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe3 + ions in practical water samples with good recovery.

  18. Estimating bergamot juice adulteration of lemon juice by high-performance liquid chromatography (HPLC) analysis of flavanone glycosides.

    PubMed

    Cautela, Domenico; Laratta, Bruna; Santelli, Francesca; Trifirò, Antonio; Servillo, Luigi; Castaldo, Domenico

    2008-07-09

    The chemical composition of 30 samples of juices obtained from bergamot (Citrus bergamia Risso and Poit.) fruits is reported and compared to the genuineness parameters adopted by Association of the Industry of Juice and Nectars (AIJN) for lemon juice. It was found that the compositional differences between the two juices are distinguishable, although with difficulty. However, these differences are not strong enough to detect the fraudulent addition of bergamot juice to lemon juice. Instead, we found the high-performance liquid chromatography (HPLC) analysis of the flavanones naringin, neohesperidin, and neoeriocitrin, which are present in bergamot juice and practically absent in the lemon juice, is a convenient way to detect and quantify the fraudulent addition of bergamot juice. The method has been validated by calculating the detection and quantification limits according to Eurachem procedures. Employing neoeriocitrin (detection limit = 0.7 mg/L) and naringin (detection limit = 1 mg/L) as markers, it is possible to detect the addition of bergamot juice to lemon juice at the 1% level. When using neohesperidin as a marker (detection limit = 1 mg/L), the minimal percentage of detectable addition of bergamot juice was about 2%. Finally, it is reported that the pattern of flavonoid content of the bergamot juice is similar to those of chinotto (Citrus myrtifolia Raf) and bitter orange (Citrus aurantium L.) juices and that it is possible to distinguish the three kinds of juices by HPLC analysis.

  19. Naked-eye detection of potassium ions in a novel gold nanoparticle aggregation-based aptasensor

    NASA Astrophysics Data System (ADS)

    Naderi, Mahboube; Hosseini, Morteza; Ganjali, Mohammad Reza

    2018-04-01

    In this work, we studied the feasibility of interaction among gold nanoparticles (AuNPs) and a cationic dye in an aptasensor system for the detection of potassium ions. The presence and absence of potassium in the solution was distinguishable by different colors (between orange and green) appeared after reaction. Cationic dye (Y5GL) acts as a new aggregator for AuNP-based sensors which changes the aggregated AuNP solution color from blue-purple to green. In the presence of K+ ions, the aptamer dissociated from the surface of the AuNP so that free AuNPs and cationic dye make the solution green. The aptasensor showed that the analytical linear range was from 10 nM to 50 mM and the detection limit was 4.4 nM. Also, we examined the practicality of this method on a simple paper based platform. The linear range of the colorimetric paper sensor covered of K+ concentration from 10 μM to 40 mM and the detection limit of 6.2 μM was obtained. The selectivity of AuNP aggregation-based sensor improved by the use of cationic dye. Rapidity, simplicity, high sensitivity and excellent selectivity made this assay suitable for practical determination of K+ in real urine samples.

  20. Detection of Landmines by Neutron Backscattering: Effects of Soil Moisture on the Detection System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baysoy, D. Y.; Subasi, M.

    2010-01-21

    Detection of buried land mines by using neutron backscattering technique (NBS) is a well established method. It depends on detecting a hydrogen anomaly in dry soil. Since a landmine and its plastic casing contain much more hydrogen atoms than the dry soil, this anomaly can be detected by observing a rise in the number of neutrons moderated to thermal or epithermal energy. But, the presence of moisture in the soil limits the effectiveness of the measurements. In this work, a landmine detection system using the NBS technique was designed. A series of Monte Carlo calculations was carried out to determinemore » the limits of the system due to the moisture content of the soil. In the simulations, an isotropic fast neutron source ({sup 252}Cf, 100 mug) and a neutron detection system which consists of five {sup 3}He detectors were used in a practicable geometry. In order to see the effects of soil moisture on the efficiency of the detection system, soils with different water contents were tested.« less

  1. Quantum-capacity-approaching codes for the detected-jump channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grassl, Markus; Wei Zhaohui; Ji Zhengfeng

    2010-12-15

    The quantum-channel capacity gives the ultimate limit for the rate at which quantum data can be reliably transmitted through a noisy quantum channel. Degradable quantum channels are among the few channels whose quantum capacities are known. Given the quantum capacity of a degradable channel, it remains challenging to find a practical coding scheme which approaches capacity. Here we discuss code designs for the detected-jump channel, a degradable channel with practical relevance describing the physics of spontaneous decay of atoms with detected photon emission. We show that this channel can be used to simulate a binary classical channel with both erasuresmore » and bit flips. The capacity of the simulated classical channel gives a lower bound on the quantum capacity of the detected-jump channel. When the jump probability is small, it almost equals the quantum capacity. Hence using a classical capacity-approaching code for the simulated classical channel yields a quantum code which approaches the quantum capacity of the detected-jump channel.« less

  2. Predictive inference for best linear combination of biomarkers subject to limits of detection.

    PubMed

    Coolen-Maturi, Tahani

    2017-08-15

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine, machine learning and credit scoring. The receiver operating characteristic (ROC) curve is a useful tool to assess the ability of a diagnostic test to discriminate between two classes or groups. In practice, multiple diagnostic tests or biomarkers are combined to improve diagnostic accuracy. Often, biomarker measurements are undetectable either below or above the so-called limits of detection (LoD). In this paper, nonparametric predictive inference (NPI) for best linear combination of two or more biomarkers subject to limits of detection is presented. NPI is a frequentist statistical method that is explicitly aimed at using few modelling assumptions, enabled through the use of lower and upper probabilities to quantify uncertainty. The NPI lower and upper bounds for the ROC curve subject to limits of detection are derived, where the objective function to maximize is the area under the ROC curve. In addition, the paper discusses the effect of restriction on the linear combination's coefficients on the analysis. Examples are provided to illustrate the proposed method. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Photon theory hypothesis about photon tunneling microscope's subwavelength resolution

    NASA Astrophysics Data System (ADS)

    Zhu, Yanbin; Ma, Junfu

    1995-09-01

    The foundation for the invention of the photon scanning tunneling microscope (PSTM) are the near field scanning optical microscope, the optical fiber technique, the total internal reflection, high sensitive opto-electronic detecting technique and computer technique etc. Recent research results show the subwavelength resolution of 1 - 3 nm is obtained. How to explain the PSTM has got such high subwavelength resolution? What value is the PSTM's limiting of subwavelength resolution? For resolving these problems this paper presented a photon theory hypothesis about PSTM that is based on the following two basic laws: (1) Photon is not only a carrier bringing energy and optical information, but also is a particle occupied fixed space size. (2) When a photon happened reflection, refraction, scattering, etc., only changed its energy and optical information carried, its particle size doesn't change. g (DOT) pphoton equals constant. Using these two basic laws to PSTM, the `evanescent field' is practically a weak photon distribution field and the detecting fiber tip diameter is practically a `gate' which size controlled the photon numbers into fiber tip. Passing through some calculation and inference, the following three conclusions can be given: (1) Under the PSTM's detection system sensitivity is high enough, the diameter D of detecting fiber tip and the near field detecting distance Z are the two most important factors to decide the subwavelength resolution of PSTM. (2) The limiting of PSTM's resolution will be given upon the conditions of D equals pphoton and Z equals pphoton, where pphoton is one photon size. (2) The final resolution limit R of PSTM will be lim R equals pphoton, D yields pphoton, Z yields pphoton.

  4. The evolving science of detection of ‘blood doping’

    PubMed Central

    Lundby, Carsten; Robach, Paul; Saltin, Bengt

    2012-01-01

    Blood doping practices in sports have been around for at least half a century and will likely remain for several years to come. The main reason for the various forms of blood doping to be common is that they are easy to perform, and the effects on exercise performance are gigantic. Yet another reason for blood doping to be a popular illicit practice is that detection is difficult. For autologous blood transfusions, for example, no direct test exists, and the direct testing of misuse with recombinant human erythropoietin (rhEpo) has proven very difficult despite a test exists. Future blood doping practice will likely include the stabilization of the transcription factor hypoxia-inducible factor which leads to an increased endogenous erythropoietin synthesis. It seems unrealistic to develop specific test against such drugs (and the copies hereof originating from illegal laboratories). In an attempt to detect and limit blood doping, the World Anti-Doping Agency (WADA) has launched the Athlete Biological Passport where indirect markers for all types of blood doping are evaluated on an individual level. The approach seemed promising, but a recent publication demonstrates the system to be incapable of detecting even a single subject as ‘suspicious’ while treated with rhEpo for 10–12 weeks. Sad to say, the hope that the 2012 London Olympics should be cleaner in regard to blood doping seems faint. We propose that WADA strengthens the quality and capacities of the National Anti-Doping Agencies and that they work more efficiently with the international sports federations in an attempt to limit blood doping. PMID:22225538

  5. Electrochemical sample matrix elimination for trace-level potentiometric detection with polymeric membrane ion-selective electrodes.

    PubMed

    Chumbimuni-Torres, Karin Y; Calvo-Marzal, Percy; Wang, Joseph; Bakker, Eric

    2008-08-01

    Potentiometric sensors are today sufficiently well understood and optimized to reach ultratrace level (subnanomolar) detection limits for numerous ions. In many cases of practical relevance, however, a high electrolyte background hampers the attainable detection limits. A particularly difficult sample matrix for potentiometric detection is seawater, where the high saline concentration forms a major interfering background and reduces the activity of most trace metals by complexation. This paper describes for the first time a hyphenated system for the online electrochemically modulated preconcentration and matrix elimination of trace metals, combined with a downstream potentiometric detection with solid contact polymeric membrane ion-selective microelectrodes. Following the preconcentration at the bismuth-coated electrode, the deposited metals are oxidized and released to a medium favorable to potentiometric detection, in this case calcium nitrate. Matrix interferences arising from the saline sample medium are thus circumvented. This concept is successfully evaluated with cadmium as a model trace element and offers potentiometric detection down to low parts per billion levels in samples containing 0.5 M NaCl background electrolyte.

  6. Electrochemical Sample Matrix Elimination for Trace Level Potentiometric Detection with Polymeric Membrane Ion-Selective Electrodes

    PubMed Central

    Chumbimuni-Torres, Karin Y.; Calvo-Marzal, Percy; Wang, Joseph; Bakker, Eric

    2008-01-01

    Potentiometric sensors are today sufficiently well understood and optimized to reach ultra-trace level (sub-nanomolar) detection limits for numerous ions. In many cases of practical relevance, however, a high electrolyte background hampers the attainable detection limits. A particularly difficult sample matrix for potentiometric detection is seawater, where the high saline concentration forms a major interfering background and reduces the activity of most trace metals by complexation. This paper describes for the first time a hyphenated system for the online electrochemically modulated preconcentration and matrix elimination (EMPM) of trace metals, combined with a downstream potentiometric detection with solid contact polymeric membrane ion-selective microelectrodes. Following the preconcentration at the bismuth coated electrodes, the deposited metals are oxidized and released to a medium favorable to potentiometric detection, in this case calcium nitrate. Matrix interferences arising from the saline sample medium are thus circumvented. This concept is successfully evaluated with cadmium as a model trace element and offers potentiometric detection down to low parts per billion levels in samples containing 0.5 M NaCl background electrolyte. PMID:18570385

  7. Supporting secure programming in web applications through interactive static analysis.

    PubMed

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2014-07-01

    Many security incidents are caused by software developers' failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases.

  8. Building Practical Apertureless Scanning Near-Field Microscopy

    NASA Astrophysics Data System (ADS)

    Gungordu, M. Zeki

    The fundamental objective of this study is to establish a functional, practical apertureless type scanning near-field optical microscope, and to figure out the working mechanism behind it. Whereas a far-field microscope can measure the propagating field's components, this gives us little information about the features of the sample. The resolution is limited to about half of the wavelength of the illuminating light. On the other hand, the a-SNOM system enables achieving non-propagating components of the field, which provides more details about the sample's features. It is really difficult to measure because the amplitude of this field decays exponentially when the tip is moved away from the sample. The sharpness of the tip is the only limitation for resolution of the a-SNOM system. Consequently, the sharp tips are achieved by using electrochemical etching, and these tips are used to detect near-field signal. Separating the weak a-SNOM system signals from the undesired background signal, the higher demodulation background suppression is utilized by lock-in detection.

  9. Supporting secure programming in web applications through interactive static analysis

    PubMed Central

    Zhu, Jun; Xie, Jing; Lipford, Heather Richter; Chu, Bill

    2013-01-01

    Many security incidents are caused by software developers’ failure to adhere to secure programming practices. Static analysis tools have been used to detect software vulnerabilities. However, their wide usage by developers is limited by the special training required to write rules customized to application-specific logic. Our approach is interactive static analysis, to integrate static analysis into Integrated Development Environment (IDE) and provide in-situ secure programming support to help developers prevent vulnerabilities during code construction. No additional training is required nor are there any assumptions on ways programs are built. Our work is motivated in part by the observation that many vulnerabilities are introduced due to failure to practice secure programming by knowledgeable developers. We implemented a prototype interactive static analysis tool as a plug-in for Java in Eclipse. Our technical evaluation of our prototype detected multiple zero-day vulnerabilities in a large open source project. Our evaluations also suggest that false positives may be limited to a very small class of use cases. PMID:25685513

  10. Method of analysis at the U.S. Geological Survey California Water Science Center, Sacramento Laboratory - determination of haloacetic acid formation potential, method validation, and quality-control practices

    USGS Publications Warehouse

    Zazzi, Barbara C.; Crepeau, Kathryn L.; Fram, Miranda S.; Bergamaschi, Brian A.

    2005-01-01

    An analytical method for the determination of haloacetic acid formation potential of water samples has been developed by the U.S. Geological Survey California Water Science Center Sacramento Laboratory. The haloacetic acid formation potential is measured by dosing water samples with chlorine under specified conditions of pH, temperature, incubation time, darkness, and residual-free chlorine. The haloacetic acids formed are bromochloroacetic acid, bromodichloroacetic acid, dibromochloroacetic acid, dibromoacetic acid, dichloroacetic acid, monobromoacetic acid, monochloroacetic acid, tribromoacetic acid, and trichloroacetic acid. They are extracted, methylated, and then analyzed using a gas chromatograph equipped with an electron capture detector. Method validation experiments were performed to determine the method accuracy, precision, and detection limit for each of the compounds. Method detection limits for these nine haloacetic acids ranged from 0.11 to 0.45 microgram per liter. Quality-control practices include the use of blanks, quality-control samples, calibration verification standards, surrogate recovery, internal standard, matrix spikes, and duplicates.

  11. Binary Detection using Multi-Hypothesis Log-Likelihood, Image Processing

    DTIC Science & Technology

    2014-03-27

    geosynchronous orbit and other scenarios important to the USAF. 2 1.3 Research objectives The question posed in this thesis is how well, if at all, can a...is important to compare them to another modern technique. The third objective is to compare results from another image detection method, specifically...Although adaptive optics is an important technique in moving closer to diffraction limited imaging, it is not currently a practical solution for all

  12. Superhydrophobic SERS substrates based on silicon hierarchical nanostructures

    NASA Astrophysics Data System (ADS)

    Chen, Xuexian; Wen, Jinxiu; Zhou, Jianhua; Zheng, Zebo; An, Di; Wang, Hao; Xie, Weiguang; Zhan, Runze; Xu, Ningsheng; Chen, Jun; She, Juncong; Chen, Huanjun; Deng, Shaozhi

    2018-02-01

    Silicon nanostructures have been cultivated as promising surface enhanced Raman scattering (SERS) substrates in terms of their low-loss optical resonance modes, facile functionalization, and compatibility with today’s state-of-the-art CMOS techniques. However, unlike their plasmonic counterparts, the electromagnetic field enhancements induced by silicon nanostructures are relatively small, which restrict their SERS sensing limit to around 10-7 M. To tackle this problem, we propose here a strategy for improving the SERS performance of silicon nanostructures by constructing silicon hierarchical nanostructures with a superhydrophobic surface. The hierarchical nanostructures are binary structures consisted of silicon nanowires (NWs) grown on micropyramids (MPs). After being modified with perfluorooctyltriethoxysilane (PFOT), the nanostructure surface shows a stable superhydrophobicity with a high contact angle of ˜160°. The substrate can allow for concentrating diluted analyte solutions into a specific area during the evaporation of the liquid droplet, whereby the analytes are aggregated into a small volume and can be easily detected by the silicon nanostructure SERS substrate. The analyte molecules (methylene blue: MB) enriched from an aqueous solution lower than 10-8 M can be readily detected. Such a detection limit is ˜100-fold lower than the conventional SERS substrates made of silicon nanostructures. Additionally, the detection limit can be further improved by functionalizing gold nanoparticles onto silicon hierarchical nanostructures, whereby the superhydrophobic characteristics and plasmonic field enhancements can be combined synergistically to give a detection limit down to ˜10-11 M. A gold nanoparticle-functionalized superhydrophobic substrate was employed to detect the spiked melamine in liquid milk. The results showed that the detection limit can be as low as 10-5 M, highlighting the potential of the proposed superhydrophobic SERS substrate in practical food safety inspection applications.

  13. Development and validation of a multiplex quantitative polymerase chain reaction assay for the detection of Mollicutes impurities in human cells, cultured under good manufacturing practice conditions, and following European Pharmacopoeia requirements and the International Conference on Harmonization guidelines.

    PubMed

    Vanni, Irene; Ugolotti, Elisabetta; Raso, Alessandro; Di Marco, Eddi; Melioli, Giovanni; Biassoni, Roberto

    2012-07-01

    The clinical applications of in vitro manipulated cultured cells and their precursors are often made use of in therapeutic trials. However, tissue cultures can be easily contaminated by the ubiquitous Mollicutes micro-organisms, which can cause various and severe alterations in cellular function. Thus methods able to detect and trace Mollicutes impurities contaminating cell cultures are required before starting any attempt to grow cells under good manufacturing practice (GMP) conditions. We developed a multiplex quantitative polymerase chain reaction (qPCR) assay specific for the 16S-23S rRNA intergenic spacer regions, for the Tuf and P1 cytoadhesin genes, able to detect contaminant Mollicutes species in a single tube reaction. The system was validated by analyzing different cell lines and the positive samples were confirmed by 16S and P1 cytoadhesin gene dideoxy sequencing. Our multiplex qPCR detection system was able to reach a sensitivity, specificity and robustness comparable with the culture and the indicator cell culture method, as required by the European Pharmacopoeia guidelines. We have developed a multiplex qPCR method, validated following International Conference on Harmonization (ICH) guidelines, as a qualitative limit test for impurities, assessing the validation characteristics of limit of detection and specificity. It also follows the European Pharmacopoeia guidelines and Food and Drug Administration (FDA) requirements.

  14. Modified Linnik microscopic interferometry for quantitative depth evaluation of diffraction-limited microgroove

    NASA Astrophysics Data System (ADS)

    Ye, Shiwei; Takahashi, Satoru; Michihata, Masaki; Takamasu, Kiyoshi

    2018-05-01

    The quality control of microgrooves is extremely crucial to ensure the performance and stability of microstructures and improve their fabrication efficiency. This paper introduces a novel optical inspection method and a modified Linnik microscopic interferometer measurement system to detect the depth of microgrooves with a width less than the diffraction limit. Using this optical method, the depth of diffraction-limited microgrooves can be related to the near-field optical phase difference, which cannot be practically observed but can be computed from practical far-field observations. Thus, a modified Linnik microscopic interferometer system based on three identical objective lenses and an optical path reversibility principle were developed. In addition, experiments for standard grating microgrooves on the silicon surface were carried out to demonstrate the feasibility and repeatability of the proposed method and developed measurement system.

  15. How can clinicians detect and treat autism early? Methodological trends of technology use in research

    PubMed Central

    Bölte, S; Bartl-Pokorny, KD; Jonsson, U; Berggren, S; Zhang, D; Kostrzewa, E; Falck-Ytter, T; Einspieler, C; Pokorny, FB; Jones, EJH; Roeyers, H; Charman, T; Marschik, PB

    2018-01-01

    We reviewed original research papers that used quantifiable technology to detect early autism spectrum disorder (ASD) and identified 376 studies from 34 countries from 1965-2013. Publications have increased significantly since 2000, with most coming from the USA. Electroencephalogram, magnetic resonance imaging and eye-tracking were the most frequently used technologies. Conclusion The use of quantifiable technology to detect early ASD has increased in recent decades, but has had limited impact on early detection and treatment. Further scientific developments are anticipated and we hope that they will increasingly be used in clinical practice for early ASD screening, diagnosis and intervention. PMID:26479859

  16. Investigation of light scattering as a technique for detecting discrete soot particles in a luminous flame

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The practicability of using a classical light-scattering technique, involving comparison of angular scattering intensity patterns with theoretically determined Mie and Rayleight patterns, to detect discrete soot particles (diameter less than 50 nm) in premixed propane/air and propane/oxygen-helium flames is considered. The experimental apparatus employed in this investigation included a laser light source, a flat-flame burner, specially coated optics, a cooled photomultiplier detector, and a lock-in voltmeter readout. Although large, agglomerated soot particles were detected and sized, it was not possible to detect small, discrete particles. The limiting factor appears to be background scattering by the system's optics.

  17. Highly selective luminescent sensing of picric acid based on a water-stable europium metal-organic framework

    NASA Astrophysics Data System (ADS)

    Xia, Tifeng; Zhu, Fengliang; Cui, Yuanjing; Yang, Yu; Wang, Zhiyu; Qian, Guodong

    2017-01-01

    A water-stable metal-organic framework (MOF) EuNDC has been synthesized for selective detection of the well-known contaminant and toxicant picric acid (PA) in aqueous solution. Due to the photo-induced electron transfer and self-absorption mechanism, EuNDC displayed rapid, selective and sensitive detection of PA with a detection limit of 37.6 ppb. Recyclability experiments revealed that EuNDC retains its initial luminescent intensity and same quenching efficiency in each cycle, suggesting high photostability and reusability for long-term sensing applications. The excellent detection performance of EuNDC makes it a promising PA sensing material for practical applications.

  18. Fault detection using a two-model test for changes in the parameters of an autoregressive time series

    NASA Technical Reports Server (NTRS)

    Scholtz, P.; Smyth, P.

    1992-01-01

    This article describes an investigation of a statistical hypothesis testing method for detecting changes in the characteristics of an observed time series. The work is motivated by the need for practical automated methods for on-line monitoring of Deep Space Network (DSN) equipment to detect failures and changes in behavior. In particular, on-line monitoring of the motor current in a DSN 34-m beam waveguide (BWG) antenna is used as an example. The algorithm is based on a measure of the information theoretic distance between two autoregressive models: one estimated with data from a dynamic reference window and one estimated with data from a sliding reference window. The Hinkley cumulative sum stopping rule is utilized to detect a change in the mean of this distance measure, corresponding to the detection of a change in the underlying process. The basic theory behind this two-model test is presented, and the problem of practical implementation is addressed, examining windowing methods, model estimation, and detection parameter assignment. Results from the five fault-transition simulations are presented to show the possible limitations of the detection method, and suggestions for future implementation are given.

  19. Proteomic Approaches in Biomarker Discovery: New Perspectives in Cancer Diagnostics

    PubMed Central

    Kocevar, Nina; Komel, Radovan

    2014-01-01

    Despite remarkable progress in proteomic methods, including improved detection limits and sensitivity, these methods have not yet been established in routine clinical practice. The main limitations, which prevent their integration into clinics, are high cost of equipment, the need for highly trained personnel, and last, but not least, the establishment of reliable and accurate protein biomarkers or panels of protein biomarkers for detection of neoplasms. Furthermore, the complexity and heterogeneity of most solid tumours present obstacles in the discovery of specific protein signatures, which could be used for early detection of cancers, for prediction of disease outcome, and for determining the response to specific therapies. However, cancer proteome, as the end-point of pathological processes that underlie cancer development and progression, could represent an important source for the discovery of new biomarkers and molecular targets for tailored therapies. PMID:24550697

  20. Highly sensitive on-site detection of glucose in human urine with naked eye based on enzymatic-like reaction mediated etching of gold nanorods.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Cheng, Fangbin; Zhang, Yaowen; Chen, Lingxin

    2017-03-15

    Based on enzymatic-like reaction mediated etching of gold nanorods (GNRs), an ultrasensitive visual method was developed for on-site detection of urine glucose. With the catalysis of MoO 4 2 - , GNRs were efficiently etched by H 2 O 2 which was generated by glucose-glucose oxidase enzymatic reaction. The etching of GNRs lead to a blue-shift of logitudinal localized surface plasmon resonance of GNRs, accompanied by an obvious color change from blue to red. The peak-shift and the color change can be used for detection of glucose by the spectrophotometer and the naked eyes. Under optimal condition, an excellent sensitivity toward glucose is obtained with a detection limit of 0.1μM and a visual detection limit of 3μM in buffer solution. Benefiting from the high sensitivity, the successful colorimetric detection of glucose in original urine samples was achieved, which indicates the practical applicability to the on-site determination of urine glucose. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A dual-responsive colorimetric and fluorescent chemosensor based on diketopyrrolopyrrole derivative for naked-eye detection of Fe3+ and its practical application.

    PubMed

    Zhang, Shanshan; Sun, Tao; Xiao, Dejun; Yuan, Fang; Li, Tianduo; Wang, Enhua; Liu, Haixia; Niu, Qingfen

    2018-01-15

    A novel dual-responsive colorimetric and fluorescent chemosensor L based on diketopyrrolopyrrole derivative for Fe 3+ detection was designed and synthesized. In presence of Fe 3+ , sensor L displayed strong colorimetric response as amaranth to rose pink and significant fluorescence enhancement and chromogenic change, which served as a naked-eye indicator by an obvious color change from purple to red. The binding constant for L-Fe 3+ complex was found as 2.4×10 4 with the lower detection limit of 14.3nM. The sensing mechanism was investigated in detail by fluorescence measurements, IR and 1 H NMR spectra. Sensor L for Fe 3+ detection also exhibited high anti-interference performance, good reversibility, wide pH response range and instantaneous response time. Furthermore, the sensor L has been used to quantify Fe 3+ ions in practical water samples with good recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The evolving science of detection of 'blood doping'.

    PubMed

    Lundby, Carsten; Robach, Paul; Saltin, Bengt

    2012-03-01

    Blood doping practices in sports have been around for at least half a century and will likely remain for several years to come. The main reason for the various forms of blood doping to be common is that they are easy to perform, and the effects on exercise performance are gigantic. Yet another reason for blood doping to be a popular illicit practice is that detection is difficult. For autologous blood transfusions, for example, no direct test exists, and the direct testing of misuse with recombinant human erythropoietin (rhEpo) has proven very difficult despite a test exists. Future blood doping practice will likely include the stabilization of the transcription factor hypoxia-inducible factor which leads to an increased endogenous erythropoietin synthesis. It seems unrealistic to develop specific test against such drugs (and the copies hereof originating from illegal laboratories). In an attempt to detect and limit blood doping, the World Anti-Doping Agency (WADA) has launched the Athlete Biological Passport where indirect markers for all types of blood doping are evaluated on an individual level. The approach seemed promising, but a recent publication demonstrates the system to be incapable of detecting even a single subject as 'suspicious' while treated with rhEpo for 10-12 weeks. Sad to say, the hope that the 2012 London Olympics should be cleaner in regard to blood doping seems faint. We propose that WADA strengthens the quality and capacities of the National Anti-Doping Agencies and that they work more efficiently with the international sports federations in an attempt to limit blood doping. © 2012 The Authors. British Journal of Pharmacology © 2012 The British Pharmacological Society.

  3. Background correction in forensic photography. II. Photography of blood under conditions of non-uniform illumination or variable substrate color--practical aspects and limitations.

    PubMed

    Wagner, John H; Miskelly, Gordon M

    2003-05-01

    The combination of photographs taken at wavelengths at and bracketing the peak of a narrow absorbance band can lead to enhanced visualization of the substance causing the narrow absorbance band. This concept can be used to detect putative bloodstains by division of a linear photographic image taken at or near 415 nm with an image obtained by averaging linear photographs taken at or near 395 and 435 nm. Nonlinear images can also be background corrected by substituting subtraction for the division. This paper details experimental applications and limitations of this technique, including wavelength selection of the illuminant and at the camera. Characterization of a digital camera to be used in such a study is also detailed. Detection limits for blood using the three wavelength correction method under optimum conditions have been determined to be as low as 1 in 900 dilution, although on strongly patterned substrates blood diluted more than twenty-fold is difficult to detect. Use of only the 435 nm photograph to estimate the background in the 415 nm image lead to a twofold improvement in detection limit on unpatterned substrates compared with the three wavelength method with the particular camera and lighting system used, but it gave poorer background correction on patterned substrates.

  4. Enhanced speed in fluorescence imaging using beat frequency multiplexing

    NASA Astrophysics Data System (ADS)

    Mikami, Hideharu; Kobayashi, Hirofumi; Wang, Yisen; Hamad, Syed; Ozeki, Yasuyuki; Goda, Keisuke

    2016-03-01

    Fluorescence imaging using radiofrequency-tagged emission (FIRE) is an emerging technique that enables higher imaging speed (namely, temporal resolution) in fluorescence microscopy compared to conventional fluorescence imaging techniques such as confocal microscopy and wide-field microscopy. It works based on the principle that it uses multiple intensity-modulated fields in an interferometric setup as excitation fields and applies frequency-division multiplexing to fluorescence signals. Unfortunately, despite its high potential, FIRE has limited imaging speed due to two practical limitations: signal bandwidth and signal detection efficiency. The signal bandwidth is limited by that of an acousto-optic deflector (AOD) employed in the setup, which is typically 100-200 MHz for the spectral range of fluorescence excitation (400-600 nm). The signal detection efficiency is limited by poor spatial mode-matching between two interfering fields to produce a modulated excitation field. Here we present a method to overcome these limitations and thus to achieve higher imaging speed than the prior version of FIRE. Our method achieves an increase in signal bandwidth by a factor of two and nearly optimal mode matching, which enables the imaging speed limited by the lifetime of the target fluorophore rather than the imaging system itself. The higher bandwidth and better signal detection efficiency work synergistically because higher bandwidth requires higher signal levels to avoid the contribution of shot noise and amplifier noise to the fluorescence signal. Due to its unprecedentedly high-speed performance, our method has a wide variety of applications in cancer detection, drug discovery, and regenerative medicine.

  5. Carcass enrichment detects Salmonella from broiler carcasses found to be negative by other sampling methods

    USDA-ARS?s Scientific Manuscript database

    The most frequently used methods to recover Salmonella from processed broiler chicken carcasses involve carcass rinsing or neck skin maceration. These methods are nondestructive and practical, but have limited sensitivity. The standard carcass rinse method uses only 7.5% of the residual rinsate an...

  6. Determination of quality parameters from statistical analysis of routine TLD dosimetry data.

    PubMed

    German, U; Weinstein, M; Pelled, O

    2006-01-01

    Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.

  7. Practical photon number detection with electric field-modulated silicon avalanche photodiodes.

    PubMed

    Thomas, O; Yuan, Z L; Shields, A J

    2012-01-24

    Low-noise single-photon detection is a prerequisite for quantum information processing using photonic qubits. In particular, detectors that are able to accurately resolve the number of photons in an incident light pulse will find application in functions such as quantum teleportation and linear optics quantum computing. More generally, such a detector will allow the advantages of quantum light detection to be extended to stronger optical signals, permitting optical measurements limited only by fluctuations in the photon number of the source. Here we demonstrate a practical high-speed device, which allows the signals arising from multiple photon-induced avalanches to be precisely discriminated. We use a type of silicon avalanche photodiode in which the lateral electric field profile is strongly modulated in order to realize a spatially multiplexed detector. Clearly discerned multiphoton signals are obtained by applying sub-nanosecond voltage gates in order to restrict the detector current.

  8. Redundancy management of inertial systems.

    NASA Technical Reports Server (NTRS)

    Mckern, R. A.; Musoff, H.

    1973-01-01

    The paper reviews developments in failure detection and isolation techniques applicable to gimballed and strapdown systems. It examines basic redundancy management goals of improved reliability, performance and logistic costs, and explores mechanizations available for both input and output data handling. The meaning of redundant system reliability in terms of available coverage, system MTBF, and mission time is presented and the practical hardware performance limitations of failure detection and isolation techniques are explored. Simulation results are presented illustrating implementation coverages attainable considering IMU performance models and mission detection threshold requirements. The implications of a complete GN&C redundancy management method on inertial techniques are also explored.

  9. Sensitive DNA detection and SNP discrimination using ultrabright SERS nanorattles and magnetic beads for malaria diagnostics.

    PubMed

    Ngo, Hoan T; Gandra, Naveen; Fales, Andrew M; Taylor, Steve M; Vo-Dinh, Tuan

    2016-07-15

    One of the major obstacles to implement nucleic acid-based molecular diagnostics at the point-of-care (POC) and in resource-limited settings is the lack of sensitive and practical DNA detection methods that can be seamlessly integrated into portable platforms. Herein we present a sensitive yet simple DNA detection method using a surface-enhanced Raman scattering (SERS) nanoplatform: the ultrabright SERS nanorattle. The method, referred to as the nanorattle-based method, involves sandwich hybridization of magnetic beads that are loaded with capture probes, target sequences, and ultrabright SERS nanorattles that are loaded with reporter probes. Upon hybridization, a magnet was applied to concentrate the hybridization sandwiches at a detection spot for SERS measurements. The ultrabright SERS nanorattles, composed of a core and a shell with resonance Raman reporters loaded in the gap space between the core and the shell, serve as SERS tags for signal detection. Using this method, a specific DNA sequence of the malaria parasite Plasmodium falciparum could be detected with a detection limit of approximately 100 attomoles. Single nucleotide polymorphism (SNP) discrimination of wild type malaria DNA and mutant malaria DNA, which confers resistance to artemisinin drugs, was also demonstrated. These test models demonstrate the molecular diagnostic potential of the nanorattle-based method to both detect and genotype infectious pathogens. Furthermore, the method's simplicity makes it a suitable candidate for integration into portable platforms for POC and in resource-limited settings applications. Copyright © 2016. Published by Elsevier B.V.

  10. Influence of Manure Application on the Environmental Resistome under Finnish Agricultural Practice with Restricted Antibiotic Use.

    PubMed

    Muurinen, Johanna; Stedtfeld, Robert; Karkman, Antti; Pärnänen, Katariina; Tiedje, James; Virta, Marko

    2017-06-06

    The co-occurrence of antibiotic-resistance genes (ARGs) and mobile genetic elements (MGEs) in farm environments can potentially foster the development of antibiotic-resistant pathogens. We studied the resistome of Finnish dairy and swine farms where use of antibiotics is limited to treating bacterial infections and manure is only applied from April to September. The resistome of manure, soil, and tile drainage water from the ditch was investigated from the beginning of the growing season until forage harvest. The relative ARG and MGE abundance was measured using a qPCR array with 363 primer pairs. Manure samples had the highest abundance of ARGs and MGEs, which increased during storage. Immediately following land application, the ARGs abundant in manure were detected in soil, but their abundance decreased over time with many becoming undetectable. This suggests that increases in ARG abundances after fertilizing are temporary and occur annually under agricultural practices that restrict antibiotic use. A few of the ARGs were detected in the ditch water, but most of them were undetected in the manure. Our results document the dissipation and dissemination off farm of ARGs under Finnish limited antibiotic use and suggest that such practices could help reduce the load of antibiotic-resistance genes in the environment.

  11. Prevalence of Screening-Detected Eating Disorders in Chinese Females and Exploratory Associations with Dietary Practices

    PubMed Central

    Watson, Hunna J.; Hamer, Robert M.; Thornton, Laura M.; Peat, Christine M.; Kleiman, Susan C.; Du, Shufa; Wang, Huijin; Bulik, Cynthia M.

    2014-01-01

    Objective China is undergoing dramatic Westernization, hence may be able to provide unique insights into the role of sociocultural factors in disease. The purpose of this exploratory study was two-fold: to describe the prevalence of screening-detected eating disorders and disordered eating in China at the first occasion of assessment in the large-scale China Health and Nutrition Survey (CHNS) and to explore the associations between dietary practices and disordered eating. Regarding the first objective, participants are provincially representative and in subsequent waves will be followed longitudinally. Method CHNS participants were recruited using multistage, cluster random sampling, beginning in 1989. In this study, participants comprised 259 female adolescents (12–17 years) and 979 women (18–35 years) who participated in the CHNS 2009 survey, which is the first CHNS survey to assess disordered eating. Dietary practice-disordered eating associations were investigated with logistic regression adjusting for age, body mass index, and urbanization. Results Of the participants, 6.3% (95% CI: 4.8, 8.2) of adults and 7.8% (95% CI: 5.0, 12.0) of adolescents had a screening-detected eating disorder. Dietary practices had non-significant associations with disordered eating at the general population level, except for protein consumption among women. There was evidence that skipping meals and a high-fat diet may confer risk. Discussion Screening-detected eating disorders in China are lower in prevalence than in developed countries. Dietary practices had fairly limited associations with disordered eating at the general population level; protein consumption, skipping meals, and a high-fat diet are candidate dietary practice exposures for disordered eating. PMID:25407415

  12. Mass spectrometer characterization of halogen gases in air at atmospheric pressure.

    PubMed

    Ivey, Michelle M; Foster, Krishna L

    2005-03-01

    We have developed a new interface for a commercial ion trap mass spectrometer equipped with APCI capable of real-time measurements of gaseous compounds with limits of detection on the order of pptv. The new interface has been tested using the detection of Br2 and Cl2 over synthetic seawater ice at atmospheric pressure as a model system. A mechanical pump is used to draw gaseous mixtures through a glass manifold into the corona discharge area, where the molecules are ionized. Analysis of bromine and chlorine in dry air show that ion intensity is affected by the pumping rate and the position of the glass manifold. The mass spectrometer signals for Br2 are linear in the 0.1-10.6 ppbv range, and the estimated 3sigma detection limit is 20 pptv. The MS signals for Cl2 are linear in the 0.2-25 ppbv range, and the estimated 3sigma detection limit is 1 ppbv. This new interface advances the field of analytical chemistry by introducing a practical modification to a commercially available ion trap mass spectrometer that expands the available methods for performing highly specific and sensitive measurements of gases in air at atmospheric pressure.

  13. Technologies for autonomous integrated lab-on-chip systems for space missions

    NASA Astrophysics Data System (ADS)

    Nascetti, A.; Caputo, D.; Scipinotti, R.; de Cesare, G.

    2016-11-01

    Lab-on-chip devices are ideal candidates for use in space missions where experiment automation, system compactness, limited weight and low sample and reagent consumption are required. Currently, however, most microfluidic systems require external desktop instrumentation to operate and interrogate the chip, thus strongly limiting their use as stand-alone systems. In order to overcome the above-mentioned limitations our research group is currently working on the design and fabrication of "true" lab-on-chip systems that integrate in a single device all the analytical steps from the sample preparation to the detection without the need for bulky external components such as pumps, syringes, radiation sources or optical detection systems. Three critical points can be identified to achieve 'true' lab-on-chip devices: sample handling, analytical detection and signal transduction. For each critical point, feasible solutions are presented and evaluated. Proposed microfluidic actuation and control is based on electrowetting on dielectrics, autonomous capillary networks and active valves. Analytical detection based on highly specific chemiluminescent reactions is used to avoid external radiation sources. Finally, the integration on the same chip of thin film sensors based on hydrogenated amorphous silicon is discussed showing practical results achieved in different sensing tasks.

  14. Market analysis of food products for detection of allergenic walnut (Juglans regia) and pecan (Carya illinoinensis) by real-time PCR.

    PubMed

    López-Calleja, Inés María; de la Cruz, Silvia; González, Isabel; García, Teresa; Martín, Rosario

    2015-06-15

    Two real-time polymerase chain reaction (PCR)-based assays for detection of walnut (Juglans regia) and pecan (Carya illinoinensis) traces in a wide range of processed foods are described here. The method consists on a real-time PCR assay targeting the ITS1 region, using a nuclease (TaqMan) probe labeled with FAM and BBQ. The method was positive for walnut and pecan respectively, and negative for all other heterologous plants and animals tested. Using a series of model samples with defined raw walnut in wheat flour and heat-treated walnut in wheat flour with a range of concentrations of 0.1-100,000 mg kg(-1), a practical detection limit of 0.1 mg kg(-1) of walnut content was estimated. Identical binary mixtures were done for pecan, reaching the same limit of detection of 0.1 mg kg(-1). The assay was successfully trialed on a total of 232 commercial foodstuffs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Remote monitoring of fish in small streams: A unified approach using PIT tags

    USGS Publications Warehouse

    Zydlewski, G.B.; Horton, G.; Dubreuil, T.; Letcher, B.; Casey, S.; Zydlewski, Joseph D.

    2006-01-01

    Accurate assessments of fish populations are often limited by re-observation or recapture events. Since the early 1990s, passive integrated transponders (PIT tags) have been used to understand the biology of many fish species. Until recently, PIT applications in small streams have been limited to physical recapture events. To maximize recapture probability, we constructed PIT antenna arrays in small streams to remotely detect individual fish. Experiences from two different laboratories (three case studies) allowed us to develop a unified approach to applying PIT technology for enhancing data assessments. Information on equipment, its installation, tag considerations, and array construction is provided. Theoretical and practical definitions are introduced to standardize metrics for assessing detection efficiency. We demonstrate how certain conditions (stream discharge, vibration, and ambient radio frequency noise) affect the detection efficiency and suggest that by monitoring these conditions, expectations of efficiency can be modified. We emphasize the importance of consistently estimating detection efficiency for fisheries applications.

  16. Inhomogeneous Poisson process rate function inference from dead-time limited observations.

    PubMed

    Verma, Gunjan; Drost, Robert J

    2017-05-01

    The estimation of an inhomogeneous Poisson process (IHPP) rate function from a set of process observations is an important problem arising in optical communications and a variety of other applications. However, because of practical limitations of detector technology, one is often only able to observe a corrupted version of the original process. In this paper, we consider how inference of the rate function is affected by dead time, a period of time after the detection of an event during which a sensor is insensitive to subsequent IHPP events. We propose a flexible nonparametric Bayesian approach to infer an IHPP rate function given dead-time limited process realizations. Simulation results illustrate the effectiveness of our inference approach and suggest its ability to extend the utility of existing sensor technology by permitting more accurate inference on signals whose observations are dead-time limited. We apply our inference algorithm to experimentally collected optical communications data, demonstrating the practical utility of our approach in the context of channel modeling and validation.

  17. Ag-Modified In2O3/ZnO Nanobundles with High Formaldehyde Gas-Sensing Performance

    PubMed Central

    Fang, Fang; Bai, Lu; Song, Dongsheng; Yang, Hongping; Sun, Xiaoming; Sun, Hongyu; Zhu, Jing

    2015-01-01

    Ag-modified In2O3/ZnO bundles with micro/nano porous structures have been designed and synthesized with by hydrothermal method continuing with dehydration process. Each bundle consists of nanoparticles, where nanogaps of 10–30 nm are present between the nanoparticles, leading to a porous structure. This porous structure brings high surface area and fast gas diffusion, enhancing the gas sensitivity. Consequently, the HCHO gas-sensing performance of the Ag-modified In2O3/ZnO bundles have been tested, with the formaldehyde-detection limit of 100 ppb (parts per billion) and the response and recover times as short as 6 s and 3 s, respectively, at 300 °C and the detection limit of 100 ppb, response time of 12 s and recover times of 6 s at 100 °C. The HCHO sensing detect limitation matches the health standard limitation on the concentration of formaldehyde for indoor air. Moreover, the strategy to synthesize the nanobundles is just two-step heating and easy to scale up. Therefore, the Ag-modified In2O3/ZnO bundles are ready for industrialization and practical applications. PMID:26287205

  18. Diamond-based electrochemical aptasensor realizing a femtomolar detection limit of bisphenol A.

    PubMed

    Ma, Yibo; Liu, Junsong; Li, Hongdong

    2017-06-15

    In this study, we designed and fabricated an electrochemical impedance aptasensor based on Au nanoparticles (Au-NPs) coated boron-doped diamond (BDD) modified with aptamers, and 6-mercapto-1-hexanol (MCH) for the detection of bisphenol A (BPA). The constructed BPA aptasensor exhibits good linearity from 1.0×10 -14 to 1.0×10 -9 molL -1 . The detection limitation of 7.2×10 -15 molL -1 was achieved, which can be attributed to the synergistic effect of combining BDD with Au-NPs, aptamers, and MCH. The examine results of BPA traces in Tris-HCl buffer and in milk, UV spectra of aptamer/BPA and interference test revealed that the novel aptasensors are of high sensitivity, specificity, stability and repeatability, which could be promising in practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A Sensitive DNA Capacitive Biosensor Using Interdigitated Electrodes

    PubMed Central

    Wang, Lei; Veselinovic, Milena; Yang, Lang; Geiss, Brian J.; Dandy, David S.; Chen, Tom

    2017-01-01

    This paper presents a label-free affinity-based capacitive biosensor using interdigitated electrodes. Using an optimized process of DNA probe preparation to minimize the effect of contaminants in commercial thiolated DNA probe, the electrode surface was functionalized with the 24-nucleotide DNA probes based on the West Nile virus sequence (Kunjin strain). The biosensor has the ability to detect complementary DNA fragments with a detection limit down to 20 DNA target molecules (1.5 aM range), making it suitable for a practical point-of-care (POC) platform for low target count clinical applications without the need for amplification. The reproducibility of the biosensor detection was improved with efficient covalent immobilization of purified single-stranded DNA probe oligomers on cleaned gold microelectrodes. In addition to the low detection limit, the biosensor showed a dynamic range of detection from 1 μL−1 to 105 μL−1 target molecules (20 to 2 million targets), making it suitable for sample analysis in a typical clinical application environment. The binding results presented in this paper were validated using fluorescent oligomers. PMID:27619528

  20. Optimization and validation of moving average quality control procedures using bias detection curves and moving average validation charts.

    PubMed

    van Rossum, Huub H; Kemperman, Hans

    2017-02-01

    To date, no practical tools are available to obtain optimal settings for moving average (MA) as a continuous analytical quality control instrument. Also, there is no knowledge of the true bias detection properties of applied MA. We describe the use of bias detection curves for MA optimization and MA validation charts for validation of MA. MA optimization was performed on a data set of previously obtained consecutive assay results. Bias introduction and MA bias detection were simulated for multiple MA procedures (combination of truncation limits, calculation algorithms and control limits) and performed for various biases. Bias detection curves were generated by plotting the median number of test results needed for bias detection against the simulated introduced bias. In MA validation charts the minimum, median, and maximum numbers of assay results required for MA bias detection are shown for various bias. Their use was demonstrated for sodium, potassium, and albumin. Bias detection curves allowed optimization of MA settings by graphical comparison of bias detection properties of multiple MA. The optimal MA was selected based on the bias detection characteristics obtained. MA validation charts were generated for selected optimal MA and provided insight into the range of results required for MA bias detection. Bias detection curves and MA validation charts are useful tools for optimization and validation of MA procedures.

  1. A New Internet Tool for Automatic Evaluation in Control Systems and Programming

    ERIC Educational Resources Information Center

    Munoz de la Pena, D.; Gomez-Estern, F.; Dormido, S.

    2012-01-01

    In this paper we present a web-based innovative education tool designed for automating the collection, evaluation and error detection in practical exercises assigned to computer programming and control engineering students. By using a student/instructor code-fusion architecture, the conceptual limits of multiple-choice tests are overcome by far.…

  2. Understanding new “exploratory” biomarker data: a first look at observed concentrations and associated detection limits

    EPA Science Inventory

    This editorial is the first of a series that each explains one practical aspect of statistics specifically tailored for biomarker data. Each editorial is focused on a very specific concept and gives the rationale, specific method, and a real-world example of a useful tool for da...

  3. Portable visible and near-infrared spectrophotometer for triglyceride measurements.

    PubMed

    Kobayashi, Takanori; Kato, Yukiko Hakariya; Tsukamoto, Megumi; Ikuta, Kazuyoshi; Sakudo, Akikazu

    2009-01-01

    An affordable and portable machine is required for the practical use of visible and near-infrared (Vis-NIR) spectroscopy. A portable fruit tester comprising a Vis-NIR spectrophotometer was modified for use in the transmittance mode and employed to quantify triglyceride levels in serum in combination with a chemometric analysis. Transmittance spectra collected in the 600- to 1100-nm region were subjected to a partial least-squares regression analysis and leave-out cross-validation to develop a chemometrics model for predicting triglyceride concentrations in serum. The model yielded a coefficient of determination in cross-validation (R2VAL) of 0.7831 with a standard error of cross-validation (SECV) of 43.68 mg/dl. The detection limit of the model was 148.79 mg/dl. Furthermore, masked samples predicted by the model yielded a coefficient of determination in prediction (R2PRED) of 0.6856 with a standard error of prediction (SEP) and detection limit of 61.54 and 159.38 mg/dl, respectively. The portable Vis-NIR spectrophotometer may prove convenient for the measurement of triglyceride concentrations in serum, although before practical use there remain obstacles, which are discussed.

  4. Technical aspects and limitations of fractional flow reserve measurement.

    PubMed

    Jerabek, Stepan; Kovarnik, Tomas

    2018-02-27

    The only indication for coronary revascularization is elimination of ischaemia. Invasive hemodynamic methods (fractional flow reserve - FFR and instantaneous wave-free ratio (iFR) are superior to coronary angiography in detection of lesions causing myocardial ischaemia. Current European guidelines for myocardial revascularization recommend using of FFR for detection of functional assessment of lesions severity in category IA and number of these procedures increases. However, routine usage of these methods requires knowledge of technical requirements and limitations. The aim of the study is to summarise good clinical practice for FFR and iFR measurements with explanation of possible technical challenges, that are necessary for increasing of measurement accuracy. Authors describe frequent technical mistakes and malpractice during invasive assessment of lesion severity in coronary arteries.

  5. Liquid biopsy for early detection of lung cancer.

    PubMed

    Hofman, Paul

    2017-01-01

    The possibility of complete recovery for a lung cancer patient depends on very early diagnosis, as it allows total surgical resection. Screening for this cancer in a high-risk population can be performed using a radiological approach, but this holds a certain number of limitations. Liquid biopsy could become an alternative and complementary screening approach to chest imaging for early diagnosis of lung cancer. Several circulating biomarkers indicative of lung cancer can be investigated in blood, such as circulating tumor cells, circulating free nucleic acids (RNA and DNA) and proteins. However, none of these biomarkers have yet been adopted in routine clinical practice and studies are ongoing to confirm or not the usefulness and practical interest in routine early diagnosis and screening for lung cancers. Several potential circulating biomarkers for the early detection of lung cancer exist. When coupled to thoracic imaging, these biomarkers must give diagnosis of a totally resectable lung cancer and potentially provide new recommendations for surveillance by imagery of high-risk populations without a detectable nodule. Optimization of the specificity and sensitivity of the detection methods as well as standardization of the techniques is essential before considering for daily practice a liquid biopsy as an early diagnostic tool, or possibly as a predictive test, of lung cancer.

  6. Power-limited low-thrust trajectory optimization with operation point detection

    NASA Astrophysics Data System (ADS)

    Chi, Zhemin; Li, Haiyang; Jiang, Fanghua; Li, Junfeng

    2018-06-01

    The power-limited solar electric propulsion system is considered more practical in mission design. An accurate mathematical model of the propulsion system, based on experimental data of the power generation system, is used in this paper. An indirect method is used to deal with the time-optimal and fuel-optimal control problems, in which the solar electric propulsion system is described using a finite number of operation points, which are characterized by different pairs of thruster input power. In order to guarantee the integral accuracy for the discrete power-limited problem, a power operation detection technique is embedded in the fourth-order Runge-Kutta algorithm with fixed step. Moreover, the logarithmic homotopy method and normalization technique are employed to overcome the difficulties caused by using indirect methods. Three numerical simulations with actual propulsion systems are given to substantiate the feasibility and efficiency of the proposed method.

  7. Detection of BCG bacteria using a magnetoresistive biosensor: A step towards a fully electronic platform for tuberculosis point-of-care detection.

    PubMed

    Barroso, Teresa G; Martins, Rui C; Fernandes, Elisabete; Cardoso, Susana; Rivas, José; Freitas, Paulo P

    2018-02-15

    Tuberculosis is one of the major public health concerns. This highly contagious disease affects more than 10.4 million people, being a leading cause of morbidity by infection. Tuberculosis is diagnosed at the point-of-care by the Ziehl-Neelsen sputum smear microscopy test. Ziehl-Neelsen is laborious, prone to human error and infection risk, with a limit of detection of 10 4 cells/mL. In resource-poor nations, a more practical test, with lower detection limit, is paramount. This work uses a magnetoresistive biosensor to detect BCG bacteria for tuberculosis diagnosis. Herein we report: i) nanoparticle assembly method and specificity for tuberculosis detection; ii) demonstration of proportionality between BCG cell concentration and magnetoresistive voltage signal; iii) application of multiplicative signal correction for systematic effects removal; iv) investigation of calibration effectiveness using chemometrics methods; and v) comparison with state-of-the-art point-of-care tuberculosis biosensors. Results present a clear correspondence between voltage signal and cell concentration. Multiplicative signal correction removes baseline shifts within and between biochip sensors, allowing accurate and precise voltage signal between different biochips. The corrected signal was used for multivariate regression models, which significantly decreased the calibration standard error from 0.50 to 0.03log 10 (cells/mL). Results show that Ziehl-Neelsen detection limits and below are achievable with the magnetoresistive biochip, when pre-processing and chemometrics are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Time-resolved singlet-oxygen luminescence detection with an efficient and practical semiconductor single-photon detector

    PubMed Central

    Boso, Gianluca; Ke, Damei; Korzh, Boris; Bouilloux, Jordan; Lange, Norbert; Zbinden, Hugo

    2015-01-01

    In clinical applications, such as PhotoDynamic Therapy, direct singlet-oxygen detection through its luminescence in the near-infrared range (1270 nm) has been a challenging task due to its low emission probability and the lack of suitable single-photon detectors. Here, we propose a practical setup based on a negative-feedback avalanche diode detector that is a viable alternative to the current state-of-the art for different clinical scenarios, especially where geometric collection efficiency is limited (e.g. fiber-based systems, confocal microscopy, scanning systems etc.). The proposed setup is characterized with Rose Bengal as a standard photosensitizer and it is used to measure the singlet-oxygen quantum yield of a new set of photosensitizers for site-selective photodynamic therapy. PMID:26819830

  9. Fundamentals and practice for ultrasensitive laser-induced fluorescence detection in microanalytical systems.

    PubMed

    Johnson, Mitchell E; Landers, James P

    2004-11-01

    Laser-induced fluorescence is an extremely sensitive method for detection in chemical separations. In addition, it is well-suited to detection in small volumes, and as such is widely used for capillary electrophoresis and microchip-based separations. This review explores the detailed instrumental conditions required for sub-zeptomole, sub-picomolar detection limits. The key to achieving the best sensitivity is to use an excitation and emission volume that is matched to the separation system and that, simultaneously, will keep scattering and luminescence background to a minimum. We discuss how this is accomplished with confocal detection, 90 degrees on-capillary detection, and sheath-flow detection. It is shown that each of these methods have their advantages and disadvantages, but that all can be used to produce extremely sensitive detectors for capillary- or microchip-based separations. Analysis of these capabilities allows prediction of the optimal means of achieving ultrasensitive detection on microchips.

  10. Homeland Security and Contraband Detection

    NASA Astrophysics Data System (ADS)

    Lanza, R. C.

    Detection of contraband and illicit materials has become increasingly important, especially since the terrorist attacks in the United States on September 11, 2001. The nature of the detection problem embodies both physics issues and a set of operational constraints that limit the practical application of neutrons. The issue under consideration is detection of materials that are considered serious threats; these may include explosives; radioactive materials, fissile materials, and other materials associated with nuclear weapons, often referred to as special nuclear material (SNM). The overriding constraint is in the physics: systems must be based on clean physics; but unlike physics experiments, detection systems work under the limitation that materials must be identified nonintrusively, without interrupting the normal flow of commerce and with a high probability of detection and a low probability of false alarms. A great deal of work has been reported in the literature on neutron-based techniques for detecting explosives and drugs. The largest impetus by far for detecting explosives comes from aviation industry requirements for inspecting luggage and, to a lesser extent, cargo. The major alternative techniques are either X-ray-based or chemical trace detection methods that look for small traces of explosive residues. The limitations of the X-ray and trace methods in detecting explosives are well known, but currently (2008) it is safe to say that no neutron- or nuclear-based technique is being used routinely for security inspection, despite extensive development of these methods. Smuggling of nuclear materials has become a concern, and neutron techniques are particularly attractive for detecting them. Given the limitations of X-ray techniques and the need for SNM detection, it is now useful to reexamine neutron methodologies, particularly imaging. A significant number of neutron-based techniques have been proposed and are under development for security applications, especially SNM detection, but describing how they work is beyond the scope of the chapter. Instead, one particular approach to neutron imaging, neutron resonance radiography (NRR), is discussed in detail as it illustrates many of the issues connected with imaging and detection.

  11. Noninvasive prenatal testing in routine clinical practice--an audit of NIPT and combined first-trimester screening in an unselected Australian population.

    PubMed

    McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus

    2016-02-01

    There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  12. [Automated analyzer of enzyme immunoassay].

    PubMed

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  13. A new fluorescent enhanced probe based on (E)-9-(2-nitrovinyl)-anthracene for the detection of bisulfite anions and its practical application

    NASA Astrophysics Data System (ADS)

    Chao, Jianbin; Liu, Yuhong; Zhang, Yan; Zhang, Yongbin; Huo, Fangjun; Yin, Caixia; Wang, Yu; Qin, Liping

    2015-07-01

    A new fluorescent enhanced probe based on (E)-9-(2-nitrovinyl)-anthracene is developed, which shows high selectivity and sensitivity for the detection of bisulfite anions at Na2HPO4 citric acid buffer solutions (pH 5.0). When addition of HSO3-, the fluorescence intensity is significantly enhanced and the probe displays apparent fluorescence color changes from non-fluorescence to blue under a UV lamp illumination, the solution color also changes from yellow to colorless. The detection limit is determined to be as low as 6.30 μM. This offers another specific colorimetric and fluorescent probe for bisulfite anions detection, furthermore it is applied in detecting the level of bisulfite in sugar samples.

  14. Counting individual ions in the air by tagging them with particles

    NASA Astrophysics Data System (ADS)

    Gorbunov, B.

    2017-07-01

    The quantification of ultra-low concentrations of molecules and ions in gases is of fundamental and practical importance for science and technology, for example, the detection of explosives in airports or biomarkers in medical diagnostics. Often the Faraday cup is employed to transfer ion concentrations in an electric current that is then amplified and measured. One of the main challenges is to increase the sensitivity of detection. A novel concept has been developed that enables detection of individual ions in gases by tagging them with neutral nano-objects. The concentration of ionized molecules was measured and a detection limit of 5 cm-3 was observed. It is anticipated that this concept opens doors for advances in detection sensitivity for many applications including security, medical diagnostic, trace chemical analysis.

  15. Detection and Quantification of Graphene-Family Nanomaterials in the Environment.

    PubMed

    Goodwin, David G; Adeleye, Adeyemi S; Sung, Lipiin; Ho, Kay T; Burgess, Robert M; Petersen, Elijah J

    2018-04-17

    An increase in production of commercial products containing graphene-family nanomaterials (GFNs) has led to concern over their release into the environment. The fate and potential ecotoxicological effects of GFNs in the environment are currently unclear, partially due to the limited analytical methods for GFN measurements. In this review, the unique properties of GFNs that are useful for their detection and quantification are discussed. The capacity of several classes of techniques to identify and/or quantify GFNs in different environmental matrices (water, soil, sediment, and organisms), after environmental transformations, and after release from a polymer matrix of a product is evaluated. Extraction and strategies to combine methods for more accurate discrimination of GFNs from environmental interferences as well as from other carbonaceous nanomaterials are recommended. Overall, a comprehensive review of the techniques available to detect and quantify GFNs are systematically presented to inform the state of the science, guide researchers in their selection of the best technique for the system under investigation, and enable further development of GFN metrology in environmental matrices. Two case studies are described to provide practical examples of choosing which techniques to utilize for detection or quantification of GFNs in specific scenarios. Because the available quantitative techniques are somewhat limited, more research is required to distinguish GFNs from other carbonaceous materials and improve the accuracy and detection limits of GFNs at more environmentally relevant concentrations.

  16. Accuracy of pulmonary auscultation to detect abnormal respiratory mechanics: a cross-sectional diagnostic study.

    PubMed

    Xavier, Glaciele Nascimento; Duarte, Antonio Carlos Magalhães; Melo-Silva, César Augusto; dos Santos, Carlos Eduardo Ventura Gaio; Amado, Veronica Moreira

    2014-12-01

    Pulmonary auscultation is a method used in clinical practice for the evaluation and detection of abnormalities relating to the respiratory system. This method has limitations, as it depends on the experience and hearing acuity of the examiner to determine adventitious sounds. In this context, it's important to analyze whether there is a correlation between auscultation of lung sounds and the behavior of the respiratory mechanical properties of the respiratory system in patients with immediate postoperative cardiac surgery. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. The Role of Coherent Detection

    NASA Technical Reports Server (NTRS)

    Zmuidzinas, J.

    2004-01-01

    Many interesting astronomical objects, such as galaxies, molecular clouds, PDRs, star - forming regions, protostars, evolved stars, planets, and comets, have rich submillimeter spectra. In order to avoid line blending, and to be able to resolve the line shape, it is often necessary to measure these spectra at high resolution. This paper discusses the relative advantages and limitations of coherent and direct detection for high resolution spectroscopy in the submillimeter and far - infrared. In principle, direct detection has a fundamental sensitivity advantage. In practice, it is di.cult to realize this advantage given the sensitivities of existing detectors and reasonable constraints on the instrument volume. Thus, coherent detection can be expected to play an important role in submillimeter and far - infrared astrophysics well into the future.

  18. Evaluation of microplate immunocapture method for detection of Vibrio cholerae, Salmonella Typhi and Shigella flexneri from food.

    PubMed

    Fakruddin, Md; Hossain, Md Nur; Ahmed, Monzur Morshed

    2017-08-29

    Improved methods with better separation and concentration ability for detection of foodborne pathogens are in constant need. The aim of this study was to evaluate microplate immunocapture (IC) method for detection of Salmonella Typhi, Shigella flexneri and Vibrio cholerae from food samples to provide a better alternative to conventional culture based methods. The IC method was optimized for incubation time, bacterial concentration, and capture efficiency. 6 h incubation and log 6 CFU/ml cell concentration provided optimal results. The method was shown to be highly specific for the pathogens concerned. Capture efficiency (CE) was around 100% of the target pathogens, whereas CE was either zero or very low for non-target pathogens. The IC method also showed better pathogen detection ability at different concentrations of cells from artificially contaminated food samples in comparison with culture based methods. Performance parameter of the method was also comparable (Detection limit- 25 CFU/25 g; sensitivity 100%; specificity-96.8%; Accuracy-96.7%), even better than culture based methods (Detection limit- 125 CFU/25 g; sensitivity 95.9%; specificity-97%; Accuracy-96.2%). The IC method poses to be the potential to be used as a method of choice for detection of foodborne pathogens in routine laboratory practice after proper validation.

  19. Immunochromatographic strip assay for the rapid and sensitive detection of Salmonella Typhimurium in artificially contaminated tomato samples.

    PubMed

    Shukla, Shruti; Leem, Hyerim; Lee, Jong-Suk; Kim, Myunghee

    2014-06-01

    This study was designed to confirm the applicability of a liposome-based immunochromatographic assay for the rapid detection of Salmonella enterica subsp. enterica serovar Typhimurium (Salmonella Typhimurium) in artificially contaminated tomato samples. To determine the detection limit and pre-enrichment incubation time (10, 12, and 18 h pre-enrichment in 1% buffered peptone water), the tests were performed with different cell numbers of Salmonella Typhimurium (3 × 10(0), 3 × 10(1), 3 × 10(2), and 3 × 10(3) CFU·mL(-1)) inoculated into 25 g of crushed tomato samples. The assay was able to detect as few as 30 Salmonella Typhimurium cells per 25 g of tomato samples (1.2 cells·g(-1)) after 12 h pre-enrichment incubation. Moreover, when the developed assay was compared with traditional morphological and biochemical culture-based methods as well as colloidal gold nanoparticle-based commercial test strips, the developed assay yielded positive results for the detection of Salmonella Typhimurium within a shorter period time. These findings confirm that the developed assay may have practical application for the sensitive detection of Salmonella Typhimurium in various food samples, including raw vegetables, with a relatively low detection limit and shorter analysis time.

  20. Binary Hypothesis Testing With Byzantine Sensors: Fundamental Tradeoff Between Security and Efficiency

    NASA Astrophysics Data System (ADS)

    Ren, Xiaoqiang; Yan, Jiaqi; Mo, Yilin

    2018-03-01

    This paper studies binary hypothesis testing based on measurements from a set of sensors, a subset of which can be compromised by an attacker. The measurements from a compromised sensor can be manipulated arbitrarily by the adversary. The asymptotic exponential rate, with which the probability of error goes to zero, is adopted to indicate the detection performance of a detector. In practice, we expect the attack on sensors to be sporadic, and therefore the system may operate with all the sensors being benign for extended period of time. This motivates us to consider the trade-off between the detection performance of a detector, i.e., the probability of error, when the attacker is absent (defined as efficiency) and the worst-case detection performance when the attacker is present (defined as security). We first provide the fundamental limits of this trade-off, and then propose a detection strategy that achieves these limits. We then consider a special case, where there is no trade-off between security and efficiency. In other words, our detection strategy can achieve the maximal efficiency and the maximal security simultaneously. Two extensions of the secure hypothesis testing problem are also studied and fundamental limits and achievability results are provided: 1) a subset of sensors, namely "secure" sensors, are assumed to be equipped with better security countermeasures and hence are guaranteed to be benign, 2) detection performance with unknown number of compromised sensors. Numerical examples are given to illustrate the main results.

  1. Towards Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice

    PubMed Central

    Hahn, Jin-Oh; Inan, Omer T.; Mestha, Lalit K.; Kim, Chang-Sei; Töreyin, Hakan; Kyal, Survi

    2015-01-01

    Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known, potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable, ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work towards putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach. PMID:26057530

  2. Assisted inhibition effect of acetylcholinesterase with n-octylphosphonic acid and application in high sensitive detection of organophosphorous pesticides by matrix-assisted laser desorption/ionization Fourier transform mass spectrometry.

    PubMed

    Cai, Tingting; Zhang, Li; Wang, Haoyang; Zhang, Jing; Guo, Yinlong

    2011-11-14

    A simple and practical approach to improve the sensitivity of acetylcholinesterase (AChE)-inhibited method has been developed for monitoring organophosphorous (OP) pesticide residues. In this work, matrix-assisted laser desorption/ionization Fourier transform mass spectrometry (MALDI-FTMS) was used to detect AChE activity. Due to its good salt-tolerance and low sample consumption, MALDI-FTMS facilitates rapid and high-throughput screening of OP pesticides. Here we describe a new method to obtain low detection limits via employing external reagents. Among candidate compounds, n-octylphosphonic acid (n-Octyl-PA) displays assistant effect to enhance AChE inhibition by OP pesticides. In presence of n-Octyl-PA, the percentages of AChE inhibition still kept correlation with OP pesticide concentrations. The detection limits were improved significantly even by 10(2)-10(3) folds in comparison with conventional enzyme-inhibited methods. Different detection limits of OP pesticides with different toxicities were as low as 0.005 μg L(-1) for high toxic pesticides and 0.05 μg L(-1) for low toxic pesticides. Besides, the reliability of results from this method to analyze cowpea samples had been demonstrated by liquid-chromatography tandem mass spectrometry (LC-MS/MS). The application of this commercial available assistant agent shows great promise to detect OP compounds in complicated biological matrix and broadens the mind for high sensitivity detection of OP pesticide residues in agricultural products. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Cutaneous T-cell lymphoma (CTCL): Current practices in blood assessment and the utility of T-cell receptor (TCR)-Vβ chain restriction.

    PubMed

    Gibson, Juliet F; Huang, Jing; Liu, Kristina J; Carlson, Kacie R; Foss, Francine; Choi, Jaehyuk; Edelson, Richard; Hussong, Jerry W; Mohl, Ramsey; Hill, Sally; Girardi, Michael

    2016-05-01

    Accurate quantification of malignant cells in the peripheral blood of patients with cutaneous T-cell lymphoma is important for early detection, prognosis, and monitoring disease burden. We sought to determine the spectrum of current clinical practices; critically evaluate elements of current International Society for Cutaneous Lymphomas (ISCL) B1 and B2 staging criteria; and assess the potential role of T-cell receptor-Vβ analysis by flow cytometry. We assessed current clinical practices by survey, and performed a retrospective analysis of 161 patients evaluated at Yale (2011-2014) to compare the sensitivity, specificity, positive predictive value, and negative predictive value of parameters for ISCL B2 staging. There was heterogeneity in clinical practices among institutions. ISCL B1 criteria did not capture 5 Yale cohort cases with immunophenotypic abnormalities that later progressed. T-cell receptor-Vβ testing was more specific than polymerase chain reaction and aided diagnosis in detecting clonality, but was of limited benefit in quantification of tumor burden. Because of limited follow-up involving a single center, further investigation will be necessary to conclude whether our proposed diagnostic algorithm is of general clinical benefit. We propose further study of modified B1 criteria: CD4/CD8 ratio 5 or greater, %CD4(+) CD26(-) 20% or greater, or %CD4(+) CD7(-) 20% or greater, with evidence of clonality. T-cell receptor-Vβ testing should be considered in future diagnostic and staging algorithms. Copyright © 2015 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Wavelength modulation spectroscopy coupled with an external-cavity quantum cascade laser operating between 7.5 and 8 µm

    NASA Astrophysics Data System (ADS)

    Maity, Abhijit; Pal, Mithun; Maithani, Sanchi; Dutta Banik, Gourab; Pradhan, Manik

    2018-04-01

    We demonstrate a mid-infrared detection strategy with 1f-normalized 2f-wavelength modulation spectroscopy (WMS-2f/1f) using a continuous wave (CW) external-cavity quantum cascade laser (EC-QCL) operating between 7.5 and 8 µm. The detailed performance of the WMS-2f/1f detection method was evaluated by making rotationally resolved measurements in the (ν 4  +  ν 5) combination band of acetylene (C2H2) at 1311.7600 cm-1. A noise-limited detection limit of three parts per billion (ppb) with an integration time of 110 s was achieved for C2H2 detection. The present high-resolution CW-EC-QCL system coupled with the WMS-2f/1f strategy was further validated with an extended range of C2H2 concentration of 0.1-1000 ppm, which shows excellent promise for real-life practical sensing applications. Finally, we utilized the WMS-2f/1f technique to measure the C2H2 concentration in the exhaled breath of smokers.

  5. Fourfold increased detection of Lynch syndrome by raising age limit for tumour genetic testing from 50 to 70 years is cost-effective.

    PubMed

    Sie, A S; Mensenkamp, A R; Adang, E M M; Ligtenberg, M J L; Hoogerbrugge, N

    2014-10-01

    Recognising colorectal cancer (CRC) patients with Lynch syndrome (LS) can increase life expectancy of these patients and their close relatives. To improve identification of this under-diagnosed disease, experts suggested raising the age limit for CRC tumour genetic testing from 50 to 70 years. The present study evaluates the efficacy and cost-effectiveness of this strategy. Probabilistic efficacy and cost-effectiveness analyses were carried out comparing tumour genetic testing of CRC diagnosed at age 70 or below (experimental strategy) versus CRC diagnosed at age 50 or below (current practice). The proportions of LS patients identified and cost-effectiveness including cascade screening of relatives, were calculated by decision analytic models based on real-life data. Using the experimental strategy, four times more LS patients can be identified among CRC patients when compared with current practice. Both the costs to detect one LS patient (€9437/carrier versus €4837/carrier), and the number needed to test for detecting one LS patient (42 versus 19) doubled. When family cascade screening was included, the experimental strategy was found to be highly cost-effective according to Dutch standards, resulting in an overall ratio of €2703 per extra life-year gained in additionally tested patients. Testing all CRC tumours diagnosed at or below age 70 for LS is cost-effective. Implementation is important as relatives from the large number of LS patients that are missed by current practice, can benefit from life-saving surveillance. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Sustaining "meaningful use" of health information technology in low-resource practices.

    PubMed

    Green, Lee A; Potworowski, Georges; Day, Anya; May-Gentile, Rachelle; Vibbert, Danielle; Maki, Bruce; Kiesel, Leslie

    2015-01-01

    The implementation of electronic health records (EHRs) has been extensively studied, but their maintenance once implemented has not. The Regional Extension Center (REC) program provides implementation assistance to priority practices-those with limited financial, technical, and organizational resources-but the assistance is time limited. Our objective was to identify potential barriers to maintenance of meaningful use of EHRs in priority primary care practices using a qualitative observational study for federally qualified health centers (FQHCs) and priority practices in Michigan. We conducted cognitive task analysis (CTA) interviews and direct observations of health information technology implementation in FQHCs. In addition, we conducted semistructured interviews with implementation specialists serving priority practices to detect emergent themes relevant to maintenance. Maintaining EHR technology will require ongoing expert technical support indefinitely beyond implementation to address upgrades and security needs. Maintaining meaningful use for quality improvement will require ongoing support for leadership and change management. Priority practices not associated with larger systems lack access to the necessary technical expertise, financial resources, and leverage with vendors to continue alone. Rural priority practices are particularly challenged, because expertise is often not available locally. Priority practices, especially in rural areas, are at high risk for falling on the wrong side of a "digital divide" as payers and regulators enact increasing expectations for EHR use and information management. For those without affiliation to maintain the necessary expert staff, ongoing support will be needed for those practices to remain viable. © 2015 Annals of Family Medicine, Inc.

  7. Non-targeted analysis of unexpected food contaminants using LC-HRMS.

    PubMed

    Kunzelmann, Marco; Winter, Martin; Åberg, Magnus; Hellenäs, Karl-Erik; Rosén, Johan

    2018-03-29

    A non-target analysis method for unexpected contaminants in food is described. Many current methods referred to as "non-target" are capable of detecting hundreds or even thousands of contaminants. However, they will typically still miss all other possible contaminants. Instead, a metabolomics approach might be used to obtain "true non-target" analysis. In the present work, such a method was optimized for improved detection capability at low concentrations. The method was evaluated using 19 chemically diverse model compounds spiked into milk samples to mimic unknown contamination. Other milk samples were used as reference samples. All samples were analyzed with UHPLC-TOF-MS (ultra-high-performance liquid chromatography time-of-flight mass spectrometry), using reversed-phase chromatography and electrospray ionization in positive mode. Data evaluation was performed by the software TracMass 2. No target lists of specific compounds were used to search for the contaminants. Instead, the software was used to sort out all features only occurring in the spiked sample data, i.e., the workflow resembled a metabolomics approach. Procedures for chemical identification of peaks were outside the scope of the study. Method, study design, and settings in the software were optimized to minimize manual evaluation and faulty or irrelevant hits and to maximize hit rate of the spiked compounds. A practical detection limit was established at 25 μg/kg. At this concentration, most compounds (17 out of 19) were detected as intact precursor ions, as fragments or as adducts. Only 2 irrelevant hits, probably natural compounds, were obtained. Limitations and possible practical use of the approach are discussed.

  8. Colorectal Cancer Screening Uptake's Association with Psychosocial and Sociodemographic Factors among Homeless Blacks and Whites

    ERIC Educational Resources Information Center

    Rogers, Charles R.; Robinson, Cendrine D.; Arroyo, Cassandra; Obidike, Ogechi Jessica; Sewali, Barrett; Okuyemi, Kolawole S.

    2017-01-01

    The homeless represent an extremely disadvantaged population that fare worse than minority groups in access to preventive services and health, and minority groups fare worse than Whites. Early detection screening for colorectal cancer (CRC) saves lives, but empirical data about CRC screening practices among homeless Blacks and Whites are limited.…

  9. Advanced boundary layer transition measurement methods for flight applications

    NASA Technical Reports Server (NTRS)

    Holmes, B. J.; Croom, C. C.; Gail, P. D.; Manuel, G. S.; Carraway, D. L.

    1986-01-01

    In modern laminar flow flight research, it is important to understand the specific cause(s) of laminar to turbulent boundary-layer transition. Such information is crucial to the exploration of the limits of practical application of laminar flow for drag reduction on aircraft. The transition modes of interest in current flight investigations include the viscous Tollmien-Schlichting instability, the inflectional instability at laminar separation, and the crossflow inflectional instability, as well as others. This paper presents the results to date of research on advanced devices and methods used for the study of laminar boundary-layer transition phenomena in the flight environment. Recent advancements in the development of arrayed hot-film devices and of a new flow visualization method are discussed. Arrayed hot-film devices have been designed to detect the presence of laminar separation, and of crossflow vorticity. The advanced flow visualization method utilizes color changes in liquid-crystal coatings to detect boundary-layer transition at high altitude flight conditions. Flight and wind tunnel data are presented to illustrate the design and operation of these advanced methods. These new research tools provide information on disturbance growth and transition mode which is essential to furthering our understanding of practical design limits for applications of laminar flow technology.

  10. Integrated poly(dimethysiloxane) with an intrinsic nonfouling property approaching "absolute" zero background in immunoassays.

    PubMed

    Ma, Hongwei; Wu, Yuanzi; Yang, Xiaoli; Liu, Xing; He, Jianan; Fu, Long; Wang, Jie; Xu, Hongke; Shi, Yi; Zhong, Renqian

    2010-08-01

    The key to achieve a highly sensitive and specific protein microarray assay is to prevent nonspecific protein adsorption to an "absolute" zero level because any signal amplification method will simultaneously amplify signal and noise. Here, we develop a novel solid supporting material, namely, polymer coated initiator integrated poly(dimethysiloxane) (iPDMS), which was able to achieve such "absolute" zero (i.e., below the detection limit of instrument). The implementation of this iPDMS enables practical and high-quality multiplexed enzyme-linked immunosorbent assay (ELISA) of 11 tumor markers. This iPDMS does not need any blocking steps and only require mild washing conditions. It also uses on an average 8-fold less capture antibodies compared with the mainstream nitrocellulose (NC) film. Besides saving time and materials, iPDMS achieved a limit-of-detection (LOD) as low as 19 pg mL(-1), which is sufficiently low for most current clinical diagnostic applications. We expect to see an immediate impact of this iPDMS on the realization of the great potential of protein microarray in research and practical uses such as large scale and high-throughput screening, clinical diagnosis, inspection, and quarantine.

  11. Apricot DNA as an indicator for persipan: detection and quantitation in marzipan using ligation-dependent probe amplification.

    PubMed

    Luber, Florian; Demmel, Anja; Hosken, Anne; Busch, Ulrich; Engel, Karl-Heinz

    2012-06-13

    The confectionery ingredient marzipan is exclusively prepared from almond kernels and sugar. The potential use of apricot kernels, so-called persipan, is an important issue for the quality assessment of marzipan. Therefore, a ligation-dependent probe amplification (LPA) assay was developed that enables a specific and sensitive detection of apricot DNA, as an indicator for the presence of persipan. The limit of detection was determined to be 0.1% persipan in marzipan. The suitability of the method was confirmed by the analysis of 20 commercially available food samples. The integration of a Prunus -specific probe in the LPA assay as a reference allowed for the relative quantitation of persipan in marzipan. The limit of quantitation was determined to be 0.5% persipan in marzipan. The analysis of two self-prepared mixtures of marzipan and persipan demonstrated the applicability of the quantitation method at concentration levels of practical relevance for quality control.

  12. Artificial neural networks in mammography interpretation and diagnostic decision making.

    PubMed

    Ayer, Turgay; Chen, Qiushi; Burnside, Elizabeth S

    2013-01-01

    Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs), in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.

  13. Validation of the LacTek test applied to spiked extracts of tissue samples: determination of performance characteristics.

    PubMed

    Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A

    1999-01-01

    LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).

  14. UV plasmonic device for sensing ethanol and acetone

    NASA Astrophysics Data System (ADS)

    Honda, Mitsuhiro; Ichikawa, Yo; Rozhin, Alex G.; Kulinich, Sergei A.

    2018-01-01

    In the present study, we demonstrate efficient detection of volatile organic vapors with improved sensitivity, exploiting the localized surface plasmon resonance of indium nanograins in the UV range (UV-LSPR). The sensitivity of deep-UV-LSPR measurements toward ethanol was observed to be 0.004 nm/ppm, which is 10 times higher than that of a previously reported visible-LSPR device based on Ag nanoprisms [Sensors 11, 8643 (2011)]. Although practical issues such as improving detection limits are still remaining, the results of the present study suggest that the new approach based on UV-LSPR may open new avenues to the detection of organic molecules in solid, liquid, and gas phases using plasmonic sensors.

  15. Automatic mine detection based on multiple features

    NASA Astrophysics Data System (ADS)

    Yu, Ssu-Hsin; Gandhe, Avinash; Witten, Thomas R.; Mehra, Raman K.

    2000-08-01

    Recent research sponsored by the Army, Navy and DARPA has significantly advanced the sensor technologies for mine detection. Several innovative sensor systems have been developed and prototypes were built to investigate their performance in practice. Most of the research has been focused on hardware design. However, in order for the systems to be in wide use instead of in limited use by a small group of well-trained experts, an automatic process for mine detection is needed to make the final decision process on mine vs. no mine easier and more straightforward. In this paper, we describe an automatic mine detection process consisting of three stage, (1) signal enhancement, (2) pixel-level mine detection, and (3) object-level mine detection. The final output of the system is a confidence measure that quantifies the presence of a mine. The resulting system was applied to real data collected using radar and acoustic technologies.

  16. Acoustic thermometry for detecting quenches in superconducting coils and conductor stacks

    NASA Astrophysics Data System (ADS)

    Marchevsky, M.; Gourlay, S. A.

    2017-01-01

    Quench detection capability is essential for reliable operation and protection of superconducting magnets, coils, cables, and machinery. We propose a quench detection technique based on sensing local temperature variations in the bulk of a superconducting winding by monitoring its transient acoustic response. Our approach is primarily aimed at coils and devices built with high-temperature superconductor materials where quench detection using standard voltage-based techniques may be inefficient due to the slow velocity of quench propagation. The acoustic sensing technique is non-invasive, fast, and capable of detecting temperature variations of less than 1 K in the interior of the superconductor cable stack in a 77 K cryogenic environment. We show results of finite element modeling and experiments conducted on a model superconductor stack demonstrating viability of the technique for practical quench detection, discuss sensitivity limits of the technique, and its various applications.

  17. Low-Complexity Noncoherent Signal Detection for Nanoscale Molecular Communications.

    PubMed

    Li, Bin; Sun, Mengwei; Wang, Siyi; Guo, Weisi; Zhao, Chenglin

    2016-01-01

    Nanoscale molecular communication is a viable way of exchanging information between nanomachines. In this investigation, a low-complexity and noncoherent signal detection technique is proposed to mitigate the inter-symbol-interference (ISI) and additive noise. In contrast to existing coherent detection methods of high complexity, the proposed noncoherent signal detector is more practical when the channel conditions are hard to acquire accurately or hidden from the receiver. The proposed scheme employs the molecular concentration difference to detect the ISI corrupted signals and we demonstrate that it can suppress the ISI effectively. The difference in molecular concentration is a stable characteristic, irrespective of the diffusion channel conditions. In terms of complexity, by excluding matrix operations or likelihood calculations, the new detection scheme is particularly suitable for nanoscale molecular communication systems with a small energy budget or limited computation resource.

  18. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    PubMed

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  19. An efficient probe for rapid detection of cyanide in water at parts per billion levels and naked-eye detection of endogenous cyanide.

    PubMed

    Kumari, Namita; Jha, Satadru; Bhattacharya, Santanu

    2014-03-01

    A new molecular probe based on an oxidized bis-indolyl skeleton has been developed for rapid and sensitive visual detection of cyanide ions in water and also for the detection of endogenously bound cyanide. The probe allows the "naked-eye" detection of cyanide ions in water with a visual color change from red to yellow (Δλmax =80 nm) with the immediate addition of the probe. It shows high selectivity towards the cyanide ion without any interference from other anions. The detection of cyanide by the probe is ratiometric, thus making the detection quantitative. A Michael-type addition reaction of the probe with the cyanide ion takes place during this chemodosimetric process. In water, the detection limit was found to be at the parts per million level, which improved drastically when a neutral micellar medium was employed, and it showed a parts-per-billion-level detection, which is even 25-fold lower than the permitted limits of cyanide in water. The probe could also efficiently detect the endogenously bound cyanide in cassava (a staple food) with a clear visual color change without requiring any sample pretreatment and/or any special reaction conditions such as pH or temperature. Thus the probe could serve as a practical naked-eye probe for "in-field" experiments without requiring any sophisticated instruments. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Highly Sensitive and Practical Detection of Plant Viruses via Electrical Impedance of Droplets on Textured Silicon-Based Devices

    PubMed Central

    Ambrico, Marianna; Ambrico, Paolo Francesco; Minafra, Angelantonio; De Stradis, Angelo; Vona, Danilo; Cicco, Stefania R.; Palumbo, Fabio; Favia, Pietro; Ligonzo, Teresa

    2016-01-01

    Early diagnosis of plant virus infections before the disease symptoms appearance may represent a significant benefit in limiting disease spread by a prompt application of appropriate containment steps. We propose a label-free procedure applied on a device structure where the electrical signal transduction is evaluated via impedance spectroscopy techniques. The device consists of a droplet suspension embedding two representative purified plant viruses i.e., Tomato mosaic virus and Turnip yellow mosaic virus, put in contact with a highly hydrophobic plasma textured silicon surface. Results show a high sensitivity of the system towards the virus particles with an interestingly low detection limit, from tens to hundreds of attomolar corresponding to pg/mL of sap, which refers, in the infection time-scale, to a concentration of virus particles in still-symptomless plants. Such a threshold limit, together with an envisaged engineering of an easily manageable device, compared to more sophisticated apparatuses, may contribute in simplifying the in-field plant virus diagnostics. PMID:27869726

  1. Sustaining “Meaningful Use” of Health Information Technology in Low-Resource Practices

    PubMed Central

    Green, Lee A.; Potworowski, Georges; Day, Anya; May-Gentile, Rachelle; Vibbert, Danielle; Maki, Bruce; Kiesel, Leslie

    2015-01-01

    PURPOSE The implementation of electronic health records (EHRs) has been extensively studied, but their maintenance once implemented has not. The Regional Extension Center (REC) program provides implementation assistance to priority practices—those with limited financial, technical, and organizational resources—but the assistance is time limited. Our objective was to identify potential barriers to maintenance of meaningful use of EHRs in priority primary care practices using a qualitative observational study for federally qualified health centers (FQHCs) and priority practices in Michigan. METHODS We conducted cognitive task analysis (CTA) interviews and direct observations of health information technology implementation in FQHCs. In addition, we conducted semistructured interviews with implementation specialists serving priority practices to detect emergent themes relevant to maintenance. RESULTS Maintaining EHR technology will require ongoing expert technical support indefinitely beyond implementation to address upgrades and security needs. Maintaining meaningful use for quality improvement will require ongoing support for leadership and change management. Priority practices not associated with larger systems lack access to the necessary technical expertise, financial resources, and leverage with vendors to continue alone. Rural priority practices are particularly challenged, because expertise is often not available locally. CONCLUSIONS Priority practices, especially in rural areas, are at high risk for falling on the wrong side of a “digital divide” as payers and regulators enact increasing expectations for EHR use and information management. For those without affiliation to maintain the necessary expert staff, ongoing support will be needed for those practices to remain viable. PMID:25583887

  2. Detection and Management of Diabetes during Pregnancy in Low Resource Settings: Insights into Past and Present Clinical Practices.

    PubMed

    Utz, Bettina; Delamou, Alexandre; Belaid, Loubna; De Brouwere, Vincent

    2016-01-01

    Background. Timely and adequate treatment is important to limit complications of diabetes affecting pregnancy, but there is a lack of knowledge on how these women are managed in low resource settings. Objective . To identify modalities of gestational diabetes detection and management in low and lower middle income countries. Methods . We conducted a scoping review of published literature and searched the databases PubMed, Web of Science, Embase, and African Index Medicus. We included all articles published until April 24, 2016, containing information on clinical practices of detection and management of gestational diabetes irrespective of publication date or language. Results . We identified 23 articles mainly from Asia and sub-Saharan Africa. The majority of studies were conducted in large tertiary care centers and hospital admission was reported in a third of publications. Ambulatory follow-up was generally done by weekly to fortnightly visits, whereas self-monitoring of blood glucose was not the norm. The cesarean section rate for pregnancies affected by diabetes ranged between 20% and 89%. Referral of newborns to special care units was common. Conclusion . The variety of reported provider practices underlines the importance of promoting latest consensus guidelines on GDM screening and management and the dissemination of information regarding their implementation.

  3. A CuNi/C Nanosheet Array Based on a Metal-Organic Framework Derivate as a Supersensitive Non-Enzymatic Glucose Sensor

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Ye, Chen; Li, Xu; Ding, Yaru; Liang, Hongbo; Zhao, Guangyu; Wang, Yan

    2018-06-01

    Bimetal catalysts are good alternatives for non-enzymatic glucose sensors owing to their low cost, high activity, good conductivity, and ease of fabrication. In the present study, a self-supported CuNi/C electrode prepared by electrodepositing Cu nanoparticles on a Ni-based metal-organic framework (MOF) derivate was used as a non-enzymatic glucose sensor. The porous construction and carbon scaffold inherited from the Ni-MOF guarantee good kinetics of the electrode process in electrochemical glucose detection. Furthermore, Cu nanoparticles disturb the array structure of MOF derived films and evidently enhance their electrochemical performances in glucose detection. Electrochemical measurements indicate that the CuNi/C electrode possesses a high sensitivity of 17.12 mA mM-1 cm-2, a low detection limit of 66.67 nM, and a wider linearity range from 0.20 to 2.72 mM. Additionally, the electrode exhibits good reusability, reproducibility, and stability, thereby catering to the practical use of glucose sensors. Similar values of glucose concentrations in human blood serum samples are detected with our electrode and with the method involving glucose-6-phosphate dehydrogenase; the results further demonstrate the practical feasibility of our electrode.

  4. Dispersion compensation of fiber optic communication system with direct detection using artificial neural networks (ANNs)

    NASA Astrophysics Data System (ADS)

    Maghrabi, Mahmoud M. T.; Kumar, Shiva; Bakr, Mohamed H.

    2018-02-01

    This work introduces a powerful digital nonlinear feed-forward equalizer (NFFE), exploiting multilayer artificial neural network (ANN). It mitigates impairments of optical communication systems arising due to the nonlinearity introduced by direct photo-detection. In a direct detection system, the detection process is nonlinear due to the fact that the photo-current is proportional to the absolute square of the electric field intensity. The proposed equalizer provides the most efficient computational cost with high equalization performance. Its performance is comparable to the benchmark compensation performance achieved by maximum-likelihood sequence estimator. The equalizer trains an ANN to act as a nonlinear filter whose impulse response removes the intersymbol interference (ISI) distortions of the optical channel. Owing to the proposed extensive training of the equalizer, it achieves the ultimate performance limit of any feed-forward equalizer (FFE). The performance and efficiency of the equalizer is investigated by applying it to various practical short-reach fiber optic communication system scenarios. These scenarios are extracted from practical metro/media access networks and data center applications. The obtained results show that the ANN-NFFE compensates for the received BER degradation and significantly increases the tolerance to the chromatic dispersion distortion.

  5. Lameness Detection in Dairy Cows: Part 2. Use of Sensors to Automatically Register Changes in Locomotion or Behavior

    PubMed Central

    Van Nuffel, Annelies; Zwertvaegher, Ingrid; Van Weyenberg, Stephanie; Pastell, Matti; Thorup, Vivi M.; Bahr, Claudia; Sonck, Bart; Saeys, Wouter

    2015-01-01

    Simple Summary As lame cows produce less milk and tendto have other health problems, finding and treating lame cows is very importantfor farmers. Sensors that measure behaviors associated with lameness in cowscan help by alerting the farmer of those cows in need of treatment. This reviewgives an overview of sensors for automated lameness detection and discussessome practical considerations for investigating and applying such systems inpractice. Abstract Despite the research on opportunities toautomatically measure lameness in cattle, lameness detection systems are notwidely available commercially and are only used on a few dairy farms. However, farmers need to be aware of the lame cows in their herds in order treat themproperly and in a timely fashion. Many papers have focused on the automatedmeasurement of gait or behavioral cow characteristics related to lameness. Inorder for such automated measurements to be used in a detection system, algorithms to distinguish between non-lame and mildly or severely lame cowsneed to be developed and validated. Few studies have reached this latter stageof the development process. Also, comparison between the different approachesis impeded by the wide range of practical settings used to measure the gait or behavioralcharacteristic (e.g., measurements during normal farming routine or duringexperiments; cows guided or walking at their own speed) and by the differentdefinitions of lame cows. In the majority of the publications, mildly lame cowsare included in the non-lame cow group, which limits the possibility of alsodetecting early lameness cases. In this review, studies that used sensortechnology to measure changes in gait or behavior of cows related to lamenessare discussed together with practical considerations when conducting lamenessresearch. In addition, other prerequisites for any lameness detection system onfarms (e.g., need for early detection, real-time measurements) are discussed. PMID:26479390

  6. Single-pixel imaging using balanced detection and a digital micromirror device

    NASA Astrophysics Data System (ADS)

    Soldevila, F.; Clemente, P.; Tajahuerce, E.; Uribe-Patarroyo, Néstor; Andrés, P.; Lancis, J.

    2018-02-01

    Over the past decade, single-pixel imaging (SPI) has established as a viable tool in scenarios where traditional imaging techniques struggle to provide images with acceptable quality in practicable times and reasonable costs. However, SPI still has several limitations inherent to the technique, such as working with spurious light and in real time. Here we present a novel approach, using complementary measurements and a single balanced detector. By using balanced detection, we improve the frame rate of the complementary measurement architectures by a factor of two. Furthermore, the use of a balanced detector provides environmental light immunity to the method.

  7. Synergistic electron transfer effect-based signal amplification strategy for the ultrasensitive detection of dopamine.

    PubMed

    Lu, Qiujun; Chen, Xiaogen; Liu, Dan; Wu, Cuiyan; Liu, Meiling; Li, Haitao; Zhang, Youyu; Yao, Shouzhuo

    2018-05-15

    The selective and sensitive detection of dopamine (DA) is of great significance for the identification of schizophrenia, Huntington's disease, and Parkinson's disease from the perspective of molecular diagnostics. So far, most of DA fluorescence sensors are based on the electron transfer from the fluorescence nanomaterials to DA-quinone. However, the limited electron transfer ability of the DA-quinone affects the level of detection sensitivity of these sensors. In this work, based on the DA can reduce Ag + into AgNPs followed by oxidized to DA-quinone, we developed a novel silicon nanoparticles-based electron transfer fluorescent sensor for the detection of DA. As electron transfer acceptor, the AgNPs and DA-quinone can quench the fluorescence of silicon nanoparticles effectively through the synergistic electron transfer effect. Compared with traditional fluorescence DA sensors, the proposed synergistic electron transfer-based sensor improves the detection sensitivity to a great extent (at least 10-fold improvement). The proposed sensor shows a low detection limit of DA, which is as low as 0.1 nM under the optimal conditions. This sensor has potential applicability for the detection of DA in practical sample. This work has been demonstrated to contribute to a substantial improvement in the sensitivity of the sensors. It also gives new insight into design electron transfer-based sensors. Copyright © 2018. Published by Elsevier B.V.

  8. Validation of the Cepheid GeneXpert for Detecting Ebola Virus in Semen.

    PubMed

    Loftis, Amy James; Quellie, Saturday; Chason, Kelly; Sumo, Emmanuel; Toukolon, Mason; Otieno, Yonnie; Ellerbrok, Heinzfried; Hobbs, Marcia M; Hoover, David; Dube, Karine; Wohl, David A; Fischer, William A

    2017-02-01

    Ebola virus (EBOV) RNA persistence in semen, reported sexual transmission, and sporadic clusters at the end of the 2013-2016 epidemic have prompted recommendations that male survivors refrain from unprotected sex unless their semen is confirmed to be EBOV free. However, there is no fully validated assay for EBOV detection in fluids other than blood. The Cepheid Xpert Ebola assay for EBOV RNA detection was validated for whole semen and blood using samples obtained from uninfected donors and spiked with inactivated EBOV. The validation procedure incorporated standards from Clinical and Laboratory Standards Institute and Good Clinical Laboratory Practices guidelines for evaluating molecular devices for use in infectious disease testing. The assay produced limits of detection of 1000 copies/mL in semen and 275 copies/mL in blood. Limits of detection for both semen and blood increased with longer intervals between collection and testing, with acceptable results obtained up to 72 hours after specimen collection. The Cepheid Xpert Ebola assay is accurate and precise for detecting EBOV in whole semen. A validated assay for EBOV RNA detection in semen informs the care of male survivors of Ebola, as well as recommendations for public health. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  9. Ultrasensitive Detection of Ebola Virus Oligonucleotide Based on Upconversion Nanoprobe/Nanoporous Membrane System.

    PubMed

    Tsang, Ming-Kiu; Ye, WeiWei; Wang, Guojing; Li, Jingming; Yang, Mo; Hao, Jianhua

    2016-01-26

    Ebola outbreaks are currently of great concern, and therefore, development of effective diagnosis methods is urgently needed. The key for lethal virus detection is high sensitivity, since early-stage detection of virus may increase the probability of survival. Here, we propose a luminescence scheme of assay consisting of BaGdF5:Yb/Er upconversion nanoparticles (UCNPs) conjugated with oligonucleotide probe and gold nanoparticles (AuNPs) linked with target Ebola virus oligonucleotide. As a proof of concept, a homogeneous assay was fabricated and tested, yielding a detection limit at picomolar level. The luminescence resonance energy transfer is ascribed to the spectral overlapping of upconversion luminescence and the absorption characteristics of AuNPs. Moreover, we anchored the UCNPs and AuNPs on a nanoporous alumina (NAAO) membrane to form a heterogeneous assay. Importantly, the detection limit was greatly improved, exhibiting a remarkable value at the femtomolar level. The enhancement is attributed to the increased light-matter interaction throughout the nanopore walls of the NAAO membrane. The specificity test suggested that the nanoprobes were specific to Ebola virus oligonucleotides. The strategy combining UCNPs, AuNPs, and NAAO membrane provides new insight into low-cost, rapid, and ultrasensitive detection of different diseases. Furthermore, we explored the feasibility of clinical application by using inactivated Ebola virus samples. The detection results showed great potential of our heterogeneous design for practical application.

  10. Significance and integration of molecular diagnostics in the framework of veterinary practice.

    PubMed

    Aranaz, Alicia

    2015-01-01

    The field of molecular diagnostics in veterinary practice is rapidly evolving. An array of molecular techniques of different complexity is available to facilitate the fast and specific diagnosis of animal diseases. The choice for the adequate technique is dependent on the mission and attributions of the laboratory and requires both a knowledge of the molecular biology basis and of its limitations. The ability to quickly detect pathogens and their characteristics would allow for precise decision-making and target measures such as prophylaxis, appropriate therapy, and biosafety plans to control disease outbreaks. In practice, taking benefit of the huge amount of data that can be obtained using molecular techniques highlights the need of collaboration between veterinarians in the laboratory and practitioners.

  11. Extending Raman's reach: enabling applications via greater sensitivity and speed

    NASA Astrophysics Data System (ADS)

    Creasey, David; Sullivan, Mike; Paul, Chris; Rathmell, Cicely

    2018-02-01

    Over the last decade, miniature fiber optic spectrometers have greatly expanded the ability of Raman spectroscopy to tackle practical applications in the field, from mobile pharmaceutical ID to hazardous material assessment in remote locations. There remains a gap, however, between the typical diode array spectrometer and their more sensitive benchtop analogs. High sensitivity, cooled Raman spectrometers have the potential to narrow that gap by providing greater sensitivity, better SNR, and faster measurement times. In this paper, we'll look at the key factors in the design of high sensitivity miniature Raman spectrometers and their associated accessories, as well as the key metric for direct comparison of these systems - limit of detection. With the availability of our high sensitivity Raman systems operating at wavelengths from the UV to NIR, many applications are now becoming practical in the field, from trace level detection to analysis of complex biological samples.

  12. Quality assurance and gastrointestinal endoscopy: an audit of 500 colonoscopic procedures.

    PubMed

    Denis, Bernard; Weiss, Anne-Marie; Peter, André; Bottlaender, Jacques; Chiappa, Pascale

    2004-12-01

    The aim of this study was to assess the quality of colonoscopic procedures in our endoscopy unit with the goal of improving performance. We prospectively audited 500 consecutive colonoscopic procedures and assessed sixty-two process or outcome indicators for each procedure. Most of the measured indicators were within standard limits: cecal intubation rate (92%), inadequate bowel preparations (24%), inappropriate procedures (9.7%), normal procedures (54%), yield for neoplasia (32%), morbidity (0.4%), and overall patient satisfaction (95.8%). Some indicators were outside standard limits suggesting our practices should be modified: endoscopy withdrawal time less than 6 minutes (78%), forceps removal of polyps (31%), resected polyps not recovered for pathological examination (12%), adenomas with villous elements (22%), patients unsatisfied because of time spent waiting for the procedure (19%), patients unsatisfied because of inadequate explanations (10%). There was no standard for a few indicators: patient discomfort (6.9%), diagnostic success (89%), therapeutic success (92%). Three new indicators were proposed: proportion of patients aged<50 years, number of normal colonoscopic procedures to perform to detect one advanced adenoma or cancer, and proportion of colonoscopic procedures causing discomfort. The diagnostic yield of colonoscopy was dependent on age, gender, indication and appropriateness of indication but not on the prescriber. This audit allowed us to evaluate our endoscopic practices and to detect certain shortcomings and deviations from standards. It enabled us to change some of our practices with the goal of improving the quality of our colonoscopic procedures.

  13. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    PubMed

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Review of the Clinical and Biologic Aspects of Human Papillomavirus-Positive Squamous Cell Carcinomas of the Head and Neck

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blitzer, Grace C.; Smith, Molly A.; Harris, Stephen L.

    Human papillomavirus (HPV), a known etiology of a subset of head-and-neck squamous cell carcinomas (HNCs), causes numerous alterations in normal cellular functions. This article reviews the biology, detection, and treatment of HPV-positive HNC. The role of HPV oncoproteins in tumor development, the natural history of HPV infection, and risk factors for and prevention of transmission of oral HPV are considered. Commonly used methods for detecting HPV infection, including limitations of these methods, are discussed to aid the practicing clinician in using these tests in their clinical practice. Clinical characteristics of HPV-positive HNC, including potential explanations for the improved outcomes seenmore » in patients with HPV-positive HNC, are assessed. Ongoing clinical trials specific for patients with HPV-positive HNC are described, and areas in need of additional research are summarized. Until the results of ongoing trials are known, treatment of HPV-positive HNC should not differ in clinical practice from treatment of similar non-HPV related cancers.« less

  15. Biosensing with optical fiber gratings

    NASA Astrophysics Data System (ADS)

    Chiavaioli, Francesco; Baldini, Francesco; Tombelli, Sara; Trono, Cosimo; Giannetti, Ambra

    2017-06-01

    Optical fiber gratings (OFGs), especially long-period gratings (LPGs) and etched or tilted fiber Bragg gratings (FBGs), are playing an increasing role in the chemical and biochemical sensing based on the measurement of a surface refractive index (RI) change through a label-free configuration. In these devices, the electric field evanescent wave at the fiber/surrounding medium interface changes its optical properties (i.e. intensity and wavelength) as a result of the RI variation due to the interaction between a biological recognition layer deposited over the fiber and the analyte under investigation. The use of OFG-based technology platforms takes the advantages of optical fiber peculiarities, which are hardly offered by the other sensing systems, such as compactness, lightness, high compatibility with optoelectronic devices (both sources and detectors), and multiplexing and remote measurement capability as the signal is spectrally modulated. During the last decade, the growing request in practical applications pushed the technology behind the OFG-based sensors over its limits by means of the deposition of thin film overlays, nanocoatings, and nanostructures, in general. Here, we review efforts toward utilizing these nanomaterials as coatings for high-performance and low-detection limit devices. Moreover, we review the recent development in OFG-based biosensing and identify some of the key challenges for practical applications. While high-performance metrics are starting to be achieved experimentally, there are still open questions pertaining to an effective and reliable detection of small molecules, possibly up to single molecule, sensing in vivo and multi-target detection using OFG-based technology platforms.

  16. A practical approach to tramway track condition monitoring: vertical track defects detection and identification using time-frequency processing technique

    NASA Astrophysics Data System (ADS)

    Bocz, Péter; Vinkó, Ákos; Posgay, Zoltán

    2018-03-01

    This paper presents an automatic method for detecting vertical track irregularities on tramway operation using acceleration measurements on trams. For monitoring of tramway tracks, an unconventional measurement setup is developed, which records the data of 3-axes wireless accelerometers mounted on wheel discs. Accelerations are processed to obtain the vertical track irregularities to determine whether the track needs to be repaired. The automatic detection algorithm is based on time-frequency distribution analysis and determines the defect locations. Admissible limits (thresholds) are given for detecting moderate and severe defects using statistical analysis. The method was validated on frequented tram lines in Budapest and accurately detected severe defects with a hit rate of 100%, with no false alarms. The methodology is also sensitive to moderate and small rail surface defects at the low operational speed.

  17. Application of a Subspace-Based Fault Detection Method to Industrial Structures

    NASA Astrophysics Data System (ADS)

    Mevel, L.; Hermans, L.; van der Auweraer, H.

    1999-11-01

    Early detection and localization of damage allow increased expectations of reliability, safety and reduction of the maintenance cost. This paper deals with the industrial validation of a technique to monitor the health of a structure in operating conditions (e.g. rotating machinery, civil constructions subject to ambient excitations, etc.) and to detect slight deviations in a modal model derived from in-operation measured data. In this paper, a statistical local approach based on covariance-driven stochastic subspace identification is proposed. The capabilities and limitations of the method with respect to health monitoring and damage detection are discussed and it is explained how the method can be practically used in industrial environments. After the successful validation of the proposed method on a few laboratory structures, its application to a sports car is discussed. The example illustrates that the method allows the early detection of a vibration-induced fatigue problem of a sports car.

  18. Urine sample used for detection of toxoplasma gondii infection by loop-mediated isothermal amplification (LAMP).

    PubMed

    Hu, Xin; Pan, Chang-Wang; Li, Ya-Fei; Wang, Han; Tan, Feng

    2012-02-01

    In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Toxoplasma gondii DNA in mice infected with T. gondii PRU strain. This LAMP assay was based on the sequence of highly repetitive B1 gene. The detection limit of T. gondii LAMP assay was 1 pg of T. gondii DNA, which was evaluated using 10-fold serially diluted DNA of cultured parasites. The LAMP assay was also highly specific for T. gondii and able to detect T. gondii DNA in urine of mice treated with dexamethasone at 90 day post infection (p.i.), although this assay could not detect the DNA in mice urine 2-6 days p.i. These results demonstrated that LAMP is effective for evaluation of therapy effectiveness for T. gondii infection. The established LAMP assay may represent a useful and practical tool for the routine diagnosis and therapeutic evaluation of human toxoplasmosis.

  19. Leak detection with expandable coatings

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Developed and evaluated is a system for leak detection that can be easily applied over separable connectors and that expands into a bubble or balloon if a leak is present. This objective is accomplished by using thin films of Parafilm tape wrapped over connectors, which are then overcoated with a special formulation. The low yield strength and the high elongation of the envelope permit bubble formation if leakage occurs. This system is appropriate for welds and other hardware besides separable connectors. The practical limit of this system appears to be for leaks exceeding 0.000001 cc/sec. If this envelope is used to trap gases for mass spectrometer inspection, leaks in the range of ten to the minus 8th power cc/sec. may be detectable.

  20. Perspectives of San Juan healthcare practitioners on the detection deficit in oral premalignant and early cancers in Puerto Rico: a qualitative research study

    PubMed Central

    2011-01-01

    Background In Puerto Rico, relative to the United States, a disparity exists in detecting oral precancers and early cancers. To identify factors leading to the deficit in early detection, we obtained the perspectives of San Juan healthcare practitioners whose practice could be involved in the detection of such oral lesions. Methods Key informant (KI) interviews were conducted with ten clinicians practicing in or around San Juan, Puerto Rico. We then triangulated our KI interview findings with other data sources, including recent literature on oral cancer detection from various geographic areas, current curricula at the University of Puerto Rico Schools of Medicine and Dental Medicine, as well as local health insurance regulations. Results Key informant-identified factors that likely contribute to the detection deficit include: many practitioners are deficient in knowledge regarding oral cancer and precancer; oral cancer screening examinations are limited regarding which patients receive them and the elements included. In Puerto Rico, specialists generally perform oral biopsies, and patient referral can be delayed by various factors, including government-subsidized health insurance, often referred to as Reforma. Reforma-based issues include often inadequate clinician knowledge regarding Reforma requirements/provisions, diagnostic delays related to Reforma bureaucracy, and among primary physicians, a perceived financial disincentive in referring Reforma patients. Conclusions Addressing these issues may be useful in reducing the deficit in detecting oral precancers and early oral cancer in Puerto Rico. PMID:21612663

  1. Hierarchical Flowerlike Gold Nanoparticles Labeled Immunochromatography Test Strip for Highly Sensitive Detection of Escherichia coli O157:H7.

    PubMed

    Zhang, Lei; Huang, Youju; Wang, Jingyun; Rong, Yun; Lai, Weihua; Zhang, Jiawei; Chen, Tao

    2015-05-19

    Gold nanoparticles (AuNPs) labeled lateral-flow test strip immunoassay (LFTS) has been widely used in biomedical, feed/food, and environmental analysis fields. Conventional ILFS assay usually uses spherical AuNPs as labeled probes and shows low detection sensitivity, which further limits its widespread practical application. Unlike spherical AuNP used as labeled probe in conventional ILFS, in our present study, a hierarchical flowerlike AuNP specific probe was designed for LFTS and further used to detect Escherichia coli O157:H7 (E. coli O157:H7). Three types of hierarchical flowerlike AuNPs, such as tipped flowerlike, popcornlike, and large-sized flowerlike AuNPs were synthesized in a one-step method. Compared with other two kinds of Au particles, tipped flowerlike AuNPs probes for LFTS particularly exhibited highly sensitive detection of E. coli O157:H7. The remarkable improvement of detection sensitivity of tipped flowerlike AuNPs probes can be achieved even as low as 10(3) colony-forming units (CFU)/mL by taking advantages of its appropriate size and hierarchical structures, which is superior over the detection performance of conventional LFTS. Using this novel tipped flower AuNPs probes, quantitative detection of E. coli O157:H7 can be obtained partially in a wide concentration range with good repeatability. This hierarchical tipped flower-shaped AuNPs probe for LFTS is promising for the practical applications in widespread analysis fields.

  2. Highly sensitive and selective detection of dopamine using one-pot synthesized highly photoluminescent silicon nanoparticles.

    PubMed

    Zhang, Xiaodong; Chen, Xiaokai; Kai, Siqi; Wang, Hong-Yin; Yang, Jingjing; Wu, Fu-Gen; Chen, Zhan

    2015-03-17

    A simple and highly efficient method for dopamine (DA) detection using water-soluble silicon nanoparticles (SiNPs) was reported. The SiNPs with a high quantum yield of 23.6% were synthesized by using a one-pot microwave-assisted method. The fluorescence quenching capability of a variety of molecules on the synthesized SiNPs has been tested; only DA molecules were found to be able to quench the fluorescence of these SiNPs effectively. Therefore, such a quenching effect can be used to selectively detect DA. All other molecules tested have little interference with the dopamine detection, including ascorbic acid, which commonly exists in cells and can possibly affect the dopamine detection. The ratio of the fluorescence intensity difference between the quenched and unquenched cases versus the fluorescence intensity without quenching (ΔI/I) was observed to be linearly proportional to the DA analyte concentration in the range from 0.005 to 10.0 μM, with a detection limit of 0.3 nM (S/N = 3). To the best of our knowledge, this is the lowest limit for DA detection reported so far. The mechanism of fluorescence quenching is attributed to the energy transfer from the SiNPs to the oxidized dopamine molecules through Förster resonance energy transfer. The reported method of SiNP synthesis is very simple and cheap, making the above sensitive and selective DA detection approach using SiNPs practical for many applications.

  3. Evaluation of sensitivity of TaqMan RT-PCR for rubella virus detection in clinical specimens.

    PubMed

    Okamoto, Kiyoko; Mori, Yoshio; Komagome, Rika; Nagano, Hideki; Miyoshi, Masahiro; Okano, Motohiko; Aoki, Yoko; Ogura, Atsushi; Hotta, Chiemi; Ogawa, Tomoko; Saikusa, Miwako; Kodama, Hiroe; Yasui, Yoshihiro; Minagawa, Hiroko; Kurata, Takako; Kanbayashi, Daiki; Kase, Tetsuo; Murata, Sachiko; Shirabe, Komei; Hamasaki, Mitsuhiro; Kato, Takashi; Otsuki, Noriyuki; Sakata, Masafumi; Komase, Katsuhiro; Takeda, Makoto

    2016-07-01

    An easy and reliable assay for detection of the rubella virus is required to strengthen rubella surveillance. Although a TaqMan RT-PCR assay for detection of the rubella virus has been established in Japan, its utility for diagnostic purposes has not been tested. To allow introduction of the TaqMan RT-PCR into the rubella surveillance system in Japan, the sensitivity of the assay was determined using representative strains for all genotypes and clinical specimens. The detection limits of the method for individual genotypes were examined using viral RNA extracted from 13 representative strains. The assay was also tested at 10 prefectural laboratories in Japan, designated as local reference laboratories for measles and rubella, to allow nationwide application of the assay. The detection limits and amplification efficiencies of the assay were similar among all the representative strains of the 13 genotypes. The TaqMan RT-PCR could detect approximately 90% of throat swab and urine samples taken up to 5days of illness. These samples were determined positive by a highly sensitive nested RT-PCR. The TaqMan RT-PCR could detect at least 10 pfu of rubella virus. Although the sensitivity was somewhat lower than that of the conventional nested RT-PCR, the TaqMan RT-PCR could be more practical to routine tests for rubella laboratory diagnosis and detection in view of the rapid response and reducing risks of contamination. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Superconducting Detectors Come of Age, or Ready to Leave the Lab

    NASA Technical Reports Server (NTRS)

    Moseley, Samuel H.

    2008-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provide a mechanism for high sensitivity detection of submillil.neter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large-scale superconducting detection systems is now being deployed. Improved understanding of the operation of these detectors, combined with rapidly improving fabrication techniques, is quickly expanding the capability of these detectors. I will review the development and application of superconductor-based detectors, the ultimate limits to their performance, and consider prospects for their future applications. Continued advances promise to enable important new measurements in physics, and with appropriate advances in cryogenic infrastncturem, ay result in the use of these detectors in everyday monitoring applications.

  5. Detecting un-authorized genetically modified organisms (GMOs) and derived materials.

    PubMed

    Holst-Jensen, Arne; Bertheau, Yves; de Loose, Marc; Grohmann, Lutz; Hamels, Sandrine; Hougs, Lotte; Morisset, Dany; Pecoraro, Sven; Pla, Maria; Van den Bulcke, Marc; Wulff, Doerte

    2012-01-01

    Genetically modified plants, in the following referred to as genetically modified organisms or GMOs, have been commercially grown for almost two decades. In 2010 approximately 10% of the total global crop acreage was planted with GMOs (James, 2011). More than 30 countries have been growing commercial GMOs, and many more have performed field trials. Although the majority of commercial GMOs both in terms of acreage and specific events belong to the four species: soybean, maize, cotton and rapeseed, there are another 20+ species where GMOs are commercialized or in the pipeline for commercialization. The number of GMOs cultivated in field trials or for commercial production has constantly increased during this time period. So have the number of species, the number of countries involved, the diversity of novel (added) genetic elements and the global trade. All of these factors contribute to the increasing complexity of detecting and correctly identifying GMO derived material. Many jurisdictions, including the European Union (EU), legally distinguish between authorized (and therefore legal) and un-authorized (and therefore illegal) GMOs. Information about the developments, field trials, authorizations, cultivation, trade and observations made in the official GMO control laboratories in different countries around the world is often limited, despite several attempts such as the OECD BioTrack for voluntary dissemination of data. This lack of information inevitably makes it challenging to detect and identify GMOs, especially the un-authorized GMOs. The present paper reviews the state of the art technologies and approaches in light of coverage, practicability, sensitivity and limitations. Emphasis is put on exemplifying practical detection of un-authorized GMOs. Although this paper has a European (EU) bias when examples are given, the contents have global relevance. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. One-step multiplex PCR method for the determination of pecan and Brazil nut allergens in food products.

    PubMed

    Hubalkova, Zora; Rencova, Eva

    2011-10-01

    A one-step polymerase chain reaction (PCR) method for the simultaneous detection of the major allergens of pecan and Brazil nuts was developed. Primer pairs for the amplification of partial sequences of genes encoding the allergens were designed and tested for their specificity on a range of food components. The targeted amplicon size was 173 bp of Ber e 1 gene of Brazil nuts and 72 bp of vicilin-like seed storage protein gene in pecan nuts. The primer pair detecting the noncoding region of the chloroplast DNA was used as the internal control of amplification. The intrinsic detection limit of the PCR method was 100 pg mL(-1) pecan or Brazil nuts DNA. The practical detection limit was 0.1% w/w (1 g kg(-1)). The method was applied for the investigation of 63 samples with the declaration of pecans, Brazil nuts, other different nut species or nuts generally. In 15 food samples pecans and Brazil nuts allergens were identified in the conformity with the food declaration. The presented multiplex PCR method is specific enough and can be used as a fast approach for the detection of major allergens of pecan or Brazil nuts in food. Copyright © 2011 Society of Chemical Industry.

  7. A novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide for sensitive detection of l-lactate tumor biomarker.

    PubMed

    Azzouzi, Sawsen; Rotariu, Lucian; Benito, Ana M; Maser, Wolfgang K; Ben Ali, Mounir; Bala, Camelia

    2015-07-15

    In this work, a novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide (RGO-AuNPs) and l-lactate dehydrogenase (LDH) was developed for the sensing of l-lactate. Firstly, the RGO-AuNPs modified screen printed electrodes were tested for NADH detection showing a wide dynamic range and a low detection limit. Next, the biosensor was constructed by incorporating both enzyme and RGO-AuNPs in a sol gel matrix derived from tetrametoxysilane and methyltrimetoxysilane. The enzyme loading, working pH, and coenzyme concentration were optimized. The biosensor linearly responded to l-lactate in the range of 10µM-5mM and showed a good specific sensitivity of 154µA/mMcm(2) with a detection limit of 0.13µM. This was accompanied by good reproducibility and operational stability. Tests on artificial serum proved that l-lactate can be determined practically without interferences from commonly interfering compounds such as urate, paracetamol and l-ascorbate. Our LDH/RGO-AuNPs/SPCE based biosensor thus performs as electrochemical device for the detection of l-lactate as a viable early cancer bio-marker. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Rapid and sensitive detection of mink circovirus by recombinase polymerase amplification.

    PubMed

    Ge, Junwei; Shi, Yunjia; Cui, Xingyang; Gu, Shanshan; Zhao, Lili; Chen, Hongyan

    2018-06-01

    To date, the pathogenic role of mink circovirus (MiCV) remains unclear, and its prevalence and economic importance are unknown. Therefore, a rapid and sensitive molecular diagnosis is necessary for disease management and epidemiological surveillance. However, only PCR methods can identify MiCV infection at present. In this study, we developed a nested PCR and established a novel recombinase polymerase amplification (RPA) assay for MiCV detection. Sensitivity analysis showed that the detection limit of nested PCR and RPA assay was 10 1 copies/reaction, and these methods were more sensitive than conventional PCR, which has a detection limit of 10 5 copies/reaction. The RPA assay had no cross-reactivity with other related viral pathogens, and amplification was completed in less than 20 min with a simple device. Further assessment of clinical samples showed that the two assays were accurate in identifying positive and negative conventional PCR samples. The detection rate of MiCV by the RPA assay in clinical samples was 38.09%, which was 97% consistent with that by the nested PCR. The developed nested PCR is a highly sensitive tool for practical use, and the RPA assay is a simple, sensitive, and potential alternative method for rapid and accurate MiCV diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Rapid detection and quantification of 2,4-dichlorophenoxyacetic acid in milk using molecularly imprinted polymers-surface-enhanced Raman spectroscopy.

    PubMed

    Hua, Marti Z; Feng, Shaolong; Wang, Shuo; Lu, Xiaonan

    2018-08-30

    We report the development of a molecularly imprinted polymers-surface-enhanced Raman spectroscopy (MIPs-SERS) method for rapid detection and quantification of a herbicide residue 2,4-dichlorophenoxyacetic acid (2,4-D) in milk. MIPs were synthesized via bulk polymerization and utilized as solid phase extraction sorbent to selectively extract and enrich 2,4-D from milk. Silver nanoparticles were synthesized to facilitate the collection of SERS spectra of the extracts. Based on the characteristic band intensity of 2,4-D (391 cm -1 ), the limit of detection was 0.006 ppm and the limit of quantification was 0.008 ppm. A simple logarithmic working range (0.01-1 ppm) was established, satisfying the sensitivity requirement referring to the maximum residue level of 2,4-D in milk in both Europe and North America. The overall test of 2,4-D for each milk sample required only 20 min including sample preparation. This MIPs-SERS method has potential for practical applications in detecting 2,4-D in agri-foods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Gaussian process surrogates for failure detection: A Bayesian experimental design approach

    NASA Astrophysics Data System (ADS)

    Wang, Hongqiao; Lin, Guang; Li, Jinglai

    2016-05-01

    An important task of uncertainty quantification is to identify the probability of undesired events, in particular, system failures, caused by various sources of uncertainties. In this work we consider the construction of Gaussian process surrogates for failure detection and failure probability estimation. In particular, we consider the situation that the underlying computer models are extremely expensive, and in this setting, determining the sampling points in the state space is of essential importance. We formulate the problem as an optimal experimental design for Bayesian inferences of the limit state (i.e., the failure boundary) and propose an efficient numerical scheme to solve the resulting optimization problem. In particular, the proposed limit-state inference method is capable of determining multiple sampling points at a time, and thus it is well suited for problems where multiple computer simulations can be performed in parallel. The accuracy and performance of the proposed method is demonstrated by both academic and practical examples.

  11. Mixed-effects location and scale Tobit joint models for heterogeneous longitudinal data with skewness, detection limits, and measurement errors.

    PubMed

    Lu, Tao

    2017-01-01

    The joint modeling of mean and variance for longitudinal data is an active research area. This type of model has the advantage of accounting for heteroscedasticity commonly observed in between and within subject variations. Most of researches focus on improving the estimating efficiency but ignore many data features frequently encountered in practice. In this article, we develop a mixed-effects location scale joint model that concurrently accounts for longitudinal data with multiple features. Specifically, our joint model handles heterogeneity, skewness, limit of detection, measurement errors in covariates which are typically observed in the collection of longitudinal data from many studies. We employ a Bayesian approach for making inference on the joint model. The proposed model and method are applied to an AIDS study. Simulation studies are performed to assess the performance of the proposed method. Alternative models under different conditions are compared.

  12. Molecularly imprinted covalent organic polymers for the selective extraction of benzoxazole fluorescent whitening agents from food samples.

    PubMed

    Ding, Hui; Wang, Rongyu; Wang, Xiao; Ji, Wenhua

    2018-06-21

    Molecularly imprinted covalent organic polymers were constructed by an imine-linking reaction between 1,3,5-triformylphloroglucinol and 2,6-diaminopyridine and used for the selective solid-phase extraction of benzoxazole fluorescent whitening agents from food samples. Binding experiments showed that imprinting sites on molecularly imprinted polymers had higher selectivity for targets compared with those of the corresponding non-imprinted polymers. Parameters affecting the solid-phase extraction procedure were examined. Under optimal conditions, actual samples were treated and the eluent was analyzed with high-performance liquid chromatography with diode-array detection. The results showed that the established method owned the wide linearity, satisfactory detection limits and quantification limits, and acceptable recoveries. Thus, this developed method possesses the practical potential to the selectively determine benzoxazole fluorescent whitening agents in complex food samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. The detection of problem analytes in a single proficiency test challenge in the absence of the Health Care Financing Administration rule violations.

    PubMed

    Cembrowski, G S; Hackney, J R; Carey, N

    1993-04-01

    The Clinical Laboratory Improvement Act of 1988 (CLIA 88) has dramatically changed proficiency testing (PT) practices having mandated (1) satisfactory PT for certain analytes as a condition of laboratory operation, (2) fixed PT limits for many of these "regulated" analytes, and (3) an increased number of PT specimens (n = 5) for each testing cycle. For many of these analytes, the fixed limits are much broader than the previously employed Standard Deviation Index (SDI) criteria. Paradoxically, there may be less incentive to identify and evaluate analytically significant outliers to improve the analytical process. Previously described "control rules" to evaluate these PT results are unworkable as they consider only two or three results. We used Monte Carlo simulations of Kodak Ektachem analyzers participating in PT to determine optimal control rules for the identification of PT results that are inconsistent with those from other laboratories using the same methods. The analysis of three representative analytes, potassium, creatine kinase, and iron was simulated with varying intrainstrument and interinstrument standard deviations (si and sg, respectively) obtained from the College of American Pathologists (Northfield, Ill) Quality Assurance Services data and Proficiency Test data, respectively. Analytical errors were simulated in each of the analytes and evaluated in terms of multiples of the interlaboratory SDI. Simple control rules for detecting systematic and random error were evaluated with power function graphs, graphs of probability of error detected vs magnitude of error. Based on the simulation results, we recommend screening all analytes for the occurrence of two or more observations exceeding the same +/- 1 SDI limit. For any analyte satisfying this condition, the mean of the observations should be calculated. For analytes with sg/si ratios between 1.0 and 1.5, a significant systematic error is signaled by the mean exceeding 1.0 SDI. Significant random error is signaled by one observation exceeding the +/- 3-SDI limit or the range of the observations exceeding 4 SDIs. For analytes with higher sg/si, significant systematic or random error is signaled by violation of the screening rule (having at least two observations exceeding the same +/- 1 SDI limit). Random error can also be signaled by one observation exceeding the +/- 1.5-SDI limit or the range of the observations exceeding 3 SDIs. We present a practical approach to the workup of apparent PT errors.

  14. Cross-platform evaluation of commercial real-time SYBR green RT-PCR kits for sensitive and rapid detection of European bat Lyssavirus type 1.

    PubMed

    Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence

    2015-01-01

    This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R (2) values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes.

  15. Cross-Platform Evaluation of Commercial Real-Time SYBR Green RT-PCR Kits for Sensitive and Rapid Detection of European Bat Lyssavirus Type 1

    PubMed Central

    Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence

    2015-01-01

    This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R 2 values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes. PMID:25785274

  16. Trellis-coded CPM for satellite-based mobile communications

    NASA Technical Reports Server (NTRS)

    Abrishamkar, Farrokh; Biglieri, Ezio

    1988-01-01

    Digital transmission for satellite-based land mobile communications is discussed. To satisfy the power and bandwidth limitations imposed on such systems, a combination of trellis coding and continuous-phase modulated signals are considered. Some schemes based on this idea are presented, and their performance is analyzed by computer simulation. The results obtained show that a scheme based on directional detection and Viterbi decoding appears promising for practical applications.

  17. Using prescribed fire to reduce the risk of large wildfires: A break-even analysis

    Treesearch

    James M. Saveland

    1987-01-01

    Nearly all wildfires are extinguished when they are still small. The 3-5% that get out of control cause 95% of all wildfire-related costs and damages (Dodge 1972, Wilson 1985). There are two ways to deal with these problem fires. One practice is to limit fire by suppressing fires as soon as possible after they are detected. Increasing the capability of suppression...

  18. Clinically Practical Magnetic Resonance Protocol for Improved Specifically in Breast Cancer Diagnosis

    DTIC Science & Technology

    2006-06-01

    MRI, MRS, DCE, Choline , Perfusion, Breast Cancer, Diagnosis, Specificity 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...data analysis, patient recruitment and consent, and can now perform these tasks independently. 3. Through interactions with the DOD representative (Dr...out at 4 cc/sec during perfusion MRI acquisition. The detection of an apparent choline compounds (Cho) peak (S/N > 2) at 3.23 ppm was defined as

  19. Policies and Practices in the Delivery of HIV Services in Correctional Agencies and Facilities: Results from a Multi-Site Survey

    PubMed Central

    Belenko, Steven; Hiller, Matthew; Visher, Christy; Copenhaver, Michael; O’Connell, Daniel; Burdon, William; Pankow, Jennifer; Clarke, Jennifer; Oser, Carrie

    2013-01-01

    HIV risk is disproportionately high among incarcerated individuals. Corrections agencies have been slow to implement evidence-based guidelines and interventions for HIV prevention, testing, and treatment. The emerging field of implementation science focuses on organizational interventions to facilitate adoption and implementation of evidence-based practices. A survey of among CJ-DATS correctional agency partners revealed that HIV policies and practices in prevention, detection and medical care varied widely, with some corrections agencies and facilities closely matching national guidelines and/or implementing evidence-based interventions. Others, principally attributed to limited resources, had numerous gaps in delivery of best HIV service practices. A brief overview is provided of a new CJ-DATS cooperative research protocol, informed by the survey findings, to test an organization-level intervention to reduce HIV service delivery gaps in corrections. PMID:24078624

  20. Evidence-based care of older people with suspected cognitive impairment in general practice: protocol for the IRIS cluster randomised trial.

    PubMed

    McKenzie, Joanne E; French, Simon D; O'Connor, Denise A; Mortimer, Duncan S; Browning, Colette J; Russell, Grant M; Grimshaw, Jeremy M; Eccles, Martin P; Francis, Jill J; Michie, Susan; Murphy, Kerry; Kossenas, Fiona; Green, Sally E

    2013-08-19

    Dementia is a common and complex condition. Evidence-based guidelines for the management of people with dementia in general practice exist; however, detection, diagnosis and disclosure of dementia have been identified as potential evidence-practice gaps. Interventions to implement guidelines into practice have had varying success. The use of theory in designing implementation interventions has been limited, but is advocated because of its potential to yield more effective interventions and aid understanding of factors modifying the magnitude of intervention effects across trials. This protocol describes methods of a randomised trial that tests a theory-informed implementation intervention that, if effective, may provide benefits for patients with dementia and their carers. This trial aims to estimate the effectiveness of a theory-informed intervention to increase GPs' (in Victoria, Australia) adherence to a clinical guideline for the detection, diagnosis, and management of dementia in general practice, compared with providing GPs with a printed copy of the guideline. Primary objectives include testing if the intervention is effective in increasing the percentage of patients with suspected cognitive impairment who receive care consistent with two key guideline recommendations: receipt of a i) formal cognitive assessment, and ii) depression assessment using a validated scale (primary outcomes for the trial). The design is a parallel cluster randomised trial, with clusters being general practices. We aim to recruit 60 practices per group. Practices will be randomised to the intervention and control groups using restricted randomisation. Patients meeting the inclusion criteria, and GPs' detection and diagnosis behaviours directed toward these patients, will be identified and measured via an electronic search of the medical records nine months after the start of the intervention. Practitioners in the control group will receive a printed copy of the guideline. In addition to receipt of the printed guideline, practitioners in the intervention group will be invited to participate in an interactive, opinion leader-led, educational face-to-face workshop. The theory-informed intervention aims to address identified barriers to and enablers of implementation of recommendations. Researchers responsible for identifying the cohort of patients with suspected cognitive impairment, and their detection and diagnosis outcomes, will be blind to group allocation. Australian New Zealand Clinical Trials Registry: ACTRN12611001032943 (date registered 28 September, 2011).

  1. Perirectal Swab Surveillance for Clostridium difficile by Use of Selective Broth Preamplification and Real-Time PCR Detection of tcdB ▿

    PubMed Central

    Curry, Scott R.; Schlackman, Jessica L.; Hamilton, Travis M.; Henderson, Tatianna K.; Brown, Nakita T.; Marsh, Jane W.; Shutt, Kathleen A.; Brooks, Maria M.; Pasculle, A. William; Muto, Carlene A.; Harrison, Lee H.

    2011-01-01

    Active surveillance testing to identify and isolate asymptomatic carriers of toxigenic Clostridium difficile has been limited by the lack of a test that is sensitive, specific, and timely enough to serve as an infection control tool. We tested DNA preamplified from perirectal surveillance specimens in a liquid medium selective for C. difficile by using a modified commercial real-time PCR assay. All fermenting specimens were subcultured, and isolates were tested for toxigenicity. Culture-positive toxigenic isolates served as the gold standard for comparison with the broth preamplification/PCR assay. The limit of detection for the assay was 1 CFU. Relative to toxigenic anaerobic culture, the sensitivity, specificity, and positive and negative predictive values of this assay were 70/70 (100.0%), 422/426 (99.1%), 70/74 (94.6%), and 422/422 (100.0%), respectively. These data demonstrate that selective broth preamplification and real-time PCR of perirectal swab specimens constitute a practical approach to the detection of asymptomatic C. difficile carriage. PMID:21880961

  2. Development of a micromanipulation method for single cell isolation of prokaryotes and its application in food safety.

    PubMed

    Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud

    2018-01-01

    For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.

  3. Rapid specific and visible detection of porcine circovirus type 3 using loop-mediated isothermal amplification (LAMP).

    PubMed

    Zheng, S; Wu, X; Shi, J; Peng, Z; Gao, M; Xin, C; Liu, Y; Wang, S; Xu, S; Han, H; Yu, J; Sun, W; Cong, X; Li, J; Wang, J

    2018-06-01

    In this study, a rapid and specific assay for the detection of porcine circovirus type 3 (PCV3) was established using loop-mediated isothermal amplification (LAMP). Four primers were specifically designed to amplify PCV3. The LAMP assay was effectively optimized to amplify PCV3 by water bath at 60°C for 60 min. The detection limit was approximately 1 × 10 1 copy in this LAMP assay. Compared to porcine circovirus type 2 (PCV2), both gE and gD genes of pseudorabies virus (PRV) and porcine parvovirus (PPV), the LAMP assay showed a high specific detection of PCV3. A visible detection method was developed using SYBR Green I to recognize the results rapidly. Based on the detection of 20 clinical tissue samples, the LAMP assay was more practical and convenient than classical PCR due to its simplicity, high sensitivity, rapidity, specificity, visibility and cost efficiency. © 2018 Blackwell Verlag GmbH.

  4. The Detection Method of Escherichia coli in Water Resources: A Review

    NASA Astrophysics Data System (ADS)

    Nurliyana, M. R.; Sahdan, M. Z.; Wibowo, K. M.; Muslihati, A.; Saim, H.; Ahmad, S. A.; Sari, Y.; Mansor, Z.

    2018-04-01

    This article reviews several approaches for Escherichia coli (E. coli) bacteria detection from conventional methods, emerging method and goes to biosensor-based techniques. Detection and enumeration of E. coli bacteria usually required long duration of time in obtaining the result since laboratory-based approach is normally used in its assessment. It requires 24 hours to 72 hours after sampling to process the culturing samples before results are available. Although faster technique for detecting E. coli in water such as Polymerase Chain Reaction (PCR) and Enzyme-Linked Immunosorbent Assay (ELISA) have been developed, it still required transporting the samples from water resources to the laboratory, high-cost, complicated equipment usage, complex procedures, as well as the requirement of skilled specialist to cope with the complexity which limit their wide spread practice in water quality detection. Recently, development of biosensor device that is easy to perform, portable, highly sensitive and selective becomes indispensable in detecting extremely lower consolidation of pathogenic E. coli bacteria in water samples.

  5. Sensitive detection of capsaicinoids using a surface plasmon resonance sensor with anti-homovanillic Acid polyclonal antibodies.

    PubMed

    Nakamura, Shingo; Yatabe, Rui; Onodera, Takeshi; Toko, Kiyoshi

    2013-11-13

    Recently, highly functional biosensors have been developed in preparation for possible large-scale terrorist attacks using chemical warfare agents. Practically applicable sensors are required to have various abilities, such as high portability and operability, the capability of performing rapid and continuous measurement, as well as high sensitivity and selectivity. We developed the detection method of capsaicinoids, the main component of some lachrymators, using a surface plasmon resonance (SPR) immunosensor as an on-site detection sensor. Homovanillic acid, which has a vanillyl group similar to capsaicinoids such as capsaicin and dihydrocapsaicin, was bound to Concholepas concholepas hemocyanin (CCH) for use as an immunogen to generate polyclonal antibodies. An indirect competitive assay was carried out to detect capsaicinoids using SPR sensor chips on which different capsaicin analogues were immobilized. For the sensor chip on which 4-hydroxy-3-methoxybenzylamine hydrochloride was immobilized, a detection limit of 150 ppb was achieved. We found that the incubation time was not required and the detection can be completed in five minutes.

  6. Mechanomyographic Parameter Extraction Methods: An Appraisal for Clinical Applications

    PubMed Central

    Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Zuniga, Jorge M.; Hasnan, Nazirah; Wahab, Ahmad Khairi Abdul

    2014-01-01

    The research conducted in the last three decades has collectively demonstrated that the skeletal muscle performance can be alternatively assessed by mechanomyographic signal (MMG) parameters. Indices of muscle performance, not limited to force, power, work, endurance and the related physiological processes underlying muscle activities during contraction have been evaluated in the light of the signal features. As a non-stationary signal that reflects several distinctive patterns of muscle actions, the illustrations obtained from the literature support the reliability of MMG in the analysis of muscles under voluntary and stimulus evoked contractions. An appraisal of the standard practice including the measurement theories of the methods used to extract parameters of the signal is vital to the application of the signal during experimental and clinical practices, especially in areas where electromyograms are contraindicated or have limited application. As we highlight the underpinning technical guidelines and domains where each method is well-suited, the limitations of the methods are also presented to position the state of the art in MMG parameters extraction, thus providing the theoretical framework for improvement on the current practices to widen the opportunity for new insights and discoveries. Since the signal modality has not been widely deployed due partly to the limited information extractable from the signals when compared with other classical techniques used to assess muscle performance, this survey is particularly relevant to the projected future of MMG applications in the realm of musculoskeletal assessments and in the real time detection of muscle activity. PMID:25479326

  7. Peak flow meter with a questionnaire and mini-spirometer to help detect asthma and COPD in real-life clinical practice: a cross-sectional study.

    PubMed

    Thorat, Yogesh T; Salvi, Sundeep S; Kodgule, Rahul R

    2017-05-09

    Peak flow meter with questionnaire and mini-spirometer are considered as alternative tools to spirometry for screening of asthma and chronic obstructive pulmonary disease. However, the accuracy of these tools together, in clinical settings for disease diagnosis, has not been studied. Two hundred consecutive patients with respiratory complaints answered a short symptom questionnaire and performed peak expiratory flow measurements, standard spirometry with Koko spirometer and mini-spirometry (COPD-6). Spirometry was repeated after bronchodilation. Physician made a final diagnosis of asthma, chronic obstructive pulmonary disease and others. One eighty nine patients (78 females) with age 51 ± 17 years with asthma (115), chronic obstructive pulmonary disease (33) and others (41) completed the study. "Breathlessness > 6months" and "cough > 6months" were important symptoms to detect obstructive airways disease. "Asymptomatic period > 2 weeks" had the best sensitivity (Sn) and specificity (Sp) to differentiate asthma and chronic obstructive pulmonary disease. A peak expiratory flow of < 80% predicted was the best cut-off to detect airflow limitation (Sn 90%, Sp 50%). Respiratory symptoms with PEF < 80% predicted, had Sn 84 and Sp 93% to detect OAD. COPD-6 device under-estimated FEV 1 by 13 mL (95% CI: -212, 185). At a cut-off of 0.75, the FEV 1 /FEV 6 had the best accuracy (Sn 80%, Sp 86%) to detect airflow limitation. Peak flow meter with few symptom questions can be effectively used in clinical practice for objective detection of asthma and chronic obstructive pulmonary disease, in the absence of good quality spirometry. Mini-spirometers are useful in detection of obstructive airways diseases but FEV 1 measured is inaccurate. DIFFERENTIATING CONDITIONS IN POORLY-EQUIPPED SETTINGS: A simple questionnaire and peak flow meter measurements can help doctors differentiate between asthma and chronic lung disease. In clinical settings where access to specialist equipment and knowledge is limited, it can be challenging for doctors to tell the difference between asthma and chronic obstructive pulmonary disease (COPD). To determine a viable alternative method for differentiating between these diseases, Rahul Kodgule and colleagues at the Chest Research Foundation in Pune, India, trialed a simplified version of two existing symptom questionnaires, combined with peak flow meter measurements. They assessed 189 patients using this method, and found it aided diagnosis with high sensitivity and specificity. Breathlessness, cough and wheeze were the minimal symptoms required for COPD diagnosis, while the length of asymptomatic periods was most helpful in distinguishing asthma from COPD.

  8. Evaluation of computer-aided detection and diagnosis systems.

    PubMed

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.

  9. BRIEF REPORT: Screening Items to Identify Patients with Limited Health Literacy Skills

    PubMed Central

    Wallace, Lorraine S; Rogers, Edwin S; Roskos, Steven E; Holiday, David B; Weiss, Barry D

    2006-01-01

    BACKGROUND Patients with limited literacy skills are routinely encountered in clinical practice, but they are not always identified by clinicians. OBJECTIVE To evaluate 3 candidate questions to determine their accuracy in identifying patients with limited or marginal health literacy skills. METHODS We studied 305 English-speaking adults attending a university-based primary care clinic. Demographic items, health literacy screening questions, and the Rapid Estimate of Adult Literacy in Medicine (REALM) were administered to patients. To determine the accuracy of the candidate questions for identifying limited or marginal health literacy skills, we plotted area under the receiver operating characteristic (AUROC) curves for each item, using REALM scores as a reference standard. RESULTS The mean age of subjects was 49.5; 67.5% were female, 85.2% Caucasian, and 81.3% insured by TennCare and/or Medicare. Fifty-four (17.7%) had limited and 52 (17.0%) had marginal health literacy skills. One screening question, “How confident are you filling out medical forms by yourself?” was accurate in detecting limited (AUROC of 0.82; 95% confidence interval [CI]=0.77 to 0.86) and limited/marginal (AUROC of 0.79; 95% CI=0.74 to 0.83) health literacy skills. This question had significantly greater AUROC than either of the other questions (P<.01) and also a greater AUROC than questions based on demographic characteristics. CONCLUSIONS One screening question may be sufficient for detecting limited and marginal health literacy skills in clinic populations. PMID:16881950

  10. Emerging technologies in autoantibody testing for rheumatic diseases.

    PubMed

    Olsen, Nancy J; Choi, May Y; Fritzler, Marvin J

    2017-07-24

    Testing for the presence of antinuclear antibodies (ANAs) is a key step in the diagnosis of systemic lupus erythematosus (SLE) and other systemic autoimmune rheumatic diseases (SARD). The standard slide-based indirect immunofluorescence (IIF) test is widely used, but is limited by a relative lack of specificity for SLE and not all SARD-ANAs are detected. Alternative immunoassays that might offer enhanced diagnostic and prognostic information have evolved, and some of these have entered clinical practice. This review summarizes the current state of ANA testing and multiplex techniques for detecting other autoantibodies, the possibility of point-of-care testing, and approaches for applications in early disease stages.

  11. Performance of Self-developing Radiography Films in LVR-15's Neutron Beams

    NASA Astrophysics Data System (ADS)

    Soltes, Jaroslav; Viererbl, Ladislav; Klupak, Vit; Vins, Miroslav; Michalcova, Bozena

    In the search for a suitable detector for demonstration neutron radiography measurements on the zero-power VR-1 training reactor at the Czech Technical University in Prague, some options were considered. Due to the reactor's low power and spatial limitations, an easy and practical solution had to be found. Self-developing films represent a flexible detection tool in x-ray imaging. Therefore, the goal of this study was to evaluate their potential for neutron detection. For this purpose, bare and converter covered films were studied in the thermal and epithermal neutron beams at the LVR-15 research reactor in Rez, Czech Republic.

  12. Fluorenone based fluorescent probe for selective "turn-on" detection of pyrophosphate and alanine

    NASA Astrophysics Data System (ADS)

    Daniel Thangadurai, T.; Nithya, I.; Manjubaashini, N.; Bhuvanesh, N.; Bharathi, G.; Nandhakumar, R.; Nataraj, D.

    2018-06-01

    To sense biologically important entities with different size and dimensions, a fluorenone based fluorescent receptor was designed and synthesized. Probe 1 displayed a distinct fluorescence enhancement emission at 565 nm for pyrophosphate and 530 nm for alanine in polar solvent. The fluorescence titration experiments confirm 1:1 stoichiometric ratio with high-binding constant and very low limit of detection (LoD) values. Receptor 1 showed a highly selective and sensitive recognition to HP2O73 - and to alanine over other competitive anions and amino acids. In addition, the fluorescence lifetime measurement and reversible binding study results support the practical importance of 1.

  13. Machine Learning to Predict, Detect, and Intervene Older Adults Vulnerable for Adverse Drug Events in the Emergency Department.

    PubMed

    Ouchi, Kei; Lindvall, Charlotta; Chai, Peter R; Boyer, Edward W

    2018-06-01

    Adverse drug events (ADEs) are common and have serious consequences in older adults. ED visits are opportunities to identify and alter the course of such vulnerable patients. Current practice, however, is limited by inaccurate reporting of medication list, time-consuming medication reconciliation, and poor ADE assessment. This manuscript describes a novel approach to predict, detect, and intervene vulnerable older adults at risk of ADE using machine learning. Toxicologists' expertise in ADE is essential to creating the machine learning algorithm. Leveraging the existing electronic health records to better capture older adults at risk of ADE in the ED may improve their care.

  14. Prevention of medication errors: detection and audit.

    PubMed

    Montesi, Germana; Lechi, Alessandro

    2009-06-01

    1. Medication errors have important implications for patient safety, and their identification is a main target in improving clinical practice errors, in order to prevent adverse events. 2. Error detection is the first crucial step. Approaches to this are likely to be different in research and routine care, and the most suitable must be chosen according to the setting. 3. The major methods for detecting medication errors and associated adverse drug-related events are chart review, computerized monitoring, administrative databases, and claims data, using direct observation, incident reporting, and patient monitoring. All of these methods have both advantages and limitations. 4. Reporting discloses medication errors, can trigger warnings, and encourages the diffusion of a culture of safe practice. Combining and comparing data from various and encourages the diffusion of a culture of safe practice sources increases the reliability of the system. 5. Error prevention can be planned by means of retroactive and proactive tools, such as audit and Failure Mode, Effect, and Criticality Analysis (FMECA). Audit is also an educational activity, which promotes high-quality care; it should be carried out regularly. In an audit cycle we can compare what is actually done against reference standards and put in place corrective actions to improve the performances of individuals and systems. 6. Patient safety must be the first aim in every setting, in order to build safer systems, learning from errors and reducing the human and fiscal costs.

  15. Integrated bio-fluorescence sensor.

    PubMed

    Thrush, Evan; Levi, Ofer; Ha, Wonill; Wang, Ke; Smith, Stephen J; Harris, James S

    2003-09-26

    Due to the recent explosion in optoelectronics for telecommunication applications, novel optoelectronic sensing structures can now be realized. In this work, we explore the integration of optoelectronic components towards miniature and portable fluorescence sensors. The integration of these micro-fabricated sensors with microfluidics and capillary networks may reduce the cost and complexity of current research instruments and open up a world of new applications in portable biological analysis systems. A novel optoelectronic design that capitalizes on current vertical-cavity surface-emitting laser (VCSEL) technology is explored. Specifically, VCSELs, optical emission filters and PIN photodetectors are fabricated as part of a monolithically integrated near-infrared fluorescence detection system. High-performance lasers and photodetectors have been characterized and integrated to form a complete sensor. Experimental results show that sensor sensitivity is limited by laser background. The laser background is caused by spontaneous emission emitted from the side of the VCSEL excitation source. Laser background will limit sensitivity in most integrated sensing designs due to locating excitation sources and photodetectors in such close proximity, and methods are proposed to reduce the laser background in such designs so that practical fluorescent detection limits can be achieved.

  16. Detectors for Tomorrow's Instruments

    NASA Technical Reports Server (NTRS)

    Moseley, Harvey

    2009-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

  17. Practical and regenerable electrochemical aptasensor based on nanoporous gold and thymine-Hg2+-thymine base pairs for Hg2+ detection.

    PubMed

    Zeng, Guangming; Zhang, Chen; Huang, Danlian; Lai, Cui; Tang, Lin; Zhou, Yaoyu; Xu, Piao; Wang, Hou; Qin, Lei; Cheng, Min

    2017-04-15

    A simple, practical and reusable electrochemical aptasensor, based on thymine-Hg 2+ -thymine (T-Hg 2+ -T) coordination chemistry and nanoporous gold (NPG) for signal amplification, was designed for sensitive and selective detection of mercury ions (Hg 2+ ). The thiol modified T-rich hairpin capture probe was self-assembled onto the surface of the NPG modified electrode for hybridizing with ferrocene-labeled T-rich probe in the presence of Hg 2+ via T-Hg 2+ -T coordination chemistry. As a result, the hairpin capture probe was opened, and the ferrocene tags were close to the NPG modified electrode. Taking advantage of the amplification effect of NPG electrode for increasing the reaction sites of thiol modified capture probe, the proposed electrochemical aptasensor could detect Hg 2+ quantitatively in the range of 0.01-5000nM, with a detection limit as low as 0.0036nM which is much lower than the maximum contamination level for Hg 2+ in drinking water defined by the U.S. Environmental Protection Agency. Moreover, the proposed electrochemical aptasensor can be regenerated by adding cysteine and Mg 2+ . The aptasensor was also used to detect Hg 2+ from real water samples, and the results showed excellent agreement with the values determined by atomic fluorescence spectrometer. This aptasensor showed a promising potential for on-site detecting Hg 2+ in drinking water. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Lameness Detection in Dairy Cows: Part 2. Use of Sensors to Automatically Register Changes in Locomotion or Behavior.

    PubMed

    Van Nuffel, Annelies; Zwertvaegher, Ingrid; Van Weyenberg, Stephanie; Pastell, Matti; Thorup, Vivi M; Bahr, Claudia; Sonck, Bart; Saeys, Wouter

    2015-08-28

    Despite the research on opportunities to automatically measure lameness in cattle, lameness detection systems are not widely available commercially and are only used on a few dairy farms. However, farmers need to be aware of the lame cows in their herds in order treat them properly and in a timely fashion. Many papers have focused on the automated measurement of gait or behavioral cow characteristics related to lameness. In order for such automated measurements to be used in a detection system, algorithms to distinguish between non-lame and mildly or severely lame cows need to be developed and validated. Few studies have reached this latter stage of the development process. Also, comparison between the different approaches is impeded by the wide range of practical settings used to measure the gait or behavioral characteristic (e.g., measurements during normal farming routine or during experiments; cows guided or walking at their own speed) and by the different definitions of lame cows. In the majority of the publications, mildly lame cows are included in the non-lame cow group, which limits the possibility of also detecting early lameness cases. In this review, studies that used sensor technology to measure changes in gait or behavior of cows related to lameness are discussed together with practical considerations when conducting lameness research. In addition, other prerequisites for any lameness detection system on farms (e.g., need for early detection, real-time measurements) are discussed.

  19. A novel colorimetric and "turn-on" fluorimetric chemosensor for selective recognition of CN- ions based on asymmetric azine derivatives in aqueous media

    NASA Astrophysics Data System (ADS)

    Pei, Peng-Xiang; Hu, Jing-Han; Long, Chen; Ni, Peng-Wei

    2018-06-01

    A novel chemosensor 2-((Z)-(((E)-quinolin-2-ylmethylene)hydrazono)methyl)phenol PX has been successfully designed and synthesized, which showed both colorimetric and "turn-on" fluorescence responses for CN- in DMSO/H2O (3:2, v/v; pH = 7.20) solution. The sensor could respond effectively to the stimulation of CN- ions via deprotonation and sensing mechanism of intramolecular charge transfer (ICT). Moreover, the sensor PX was successfully utilized to detect CN- in bitter almond, and the detection limit on fluorescence response of PX towards CN- was down to 4.5 × 10-7 M. Test strips containing PX were also prepared, which could act as a practical colorimetric tool to detect CN- in aqueous media.

  20. Identification Of Cells With A Compact Microscope Imaging System With Intelligent Controls

    NASA Technical Reports Server (NTRS)

    McDowell, Mark (Inventor)

    2006-01-01

    A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking mic?oscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

  1. Employing a hydrazine linked asymmetric double naphthalene hybrid for efficient naked eye detection of F-: Crystal structure with real application for F-

    NASA Astrophysics Data System (ADS)

    Bhattacharyya, Arghyadeep; Makhal, Subhash Chandra; Ghosh, Soumen; Guchhait, Nikhil

    2018-06-01

    An asymmetric hydrazide, (12E, 13E)-2-((naphthalen-1-yl) methylene)-1-(1-(2-hydroxynaphthalen-6-yl) ethylidene) hydrazine (abbreviated as AH) is synthesized and characterized by standard techniques and crystal structure of AH has been obtained. The naked eye detection of F- in aqueous acetonitrile (acetonitrile: water = 7:3/v:v) by AH has been investigated by UV-Visible titration and in presence of other anions, the limit of detection being 1.31 × 10-6(M). The mechanism of F- sensing has been explored by 1H NMR titration. AH undergoes hydrogen bonding with F- followed by deprotonation. The practical utility of AH has been explored by successful test kit response and color change in toothpaste solution.

  2. Tracking of Cells with a Compact Microscope Imaging System with Intelligent Controls

    NASA Technical Reports Server (NTRS)

    McDowell, Mark (Inventor)

    2007-01-01

    A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously

  3. Tracking of cells with a compact microscope imaging system with intelligent controls

    NASA Technical Reports Server (NTRS)

    McDowell, Mark (Inventor)

    2007-01-01

    A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to auto-focus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

  4. Operation of a Cartesian Robotic System in a Compact Microscope with Intelligent Controls

    NASA Technical Reports Server (NTRS)

    McDowell, Mark (Inventor)

    2006-01-01

    A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to autofocus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

  5. Task-oriented situation recognition

    NASA Astrophysics Data System (ADS)

    Bauer, Alexander; Fischer, Yvonne

    2010-04-01

    From the advances in computer vision methods for the detection, tracking and recognition of objects in video streams, new opportunities for video surveillance arise: In the future, automated video surveillance systems will be able to detect critical situations early enough to enable an operator to take preventive actions, instead of using video material merely for forensic investigations. However, problems such as limited computational resources, privacy regulations and a constant change in potential threads have to be addressed by a practical automated video surveillance system. In this paper, we show how these problems can be addressed using a task-oriented approach. The system architecture of the task-oriented video surveillance system NEST and an algorithm for the detection of abnormal behavior as part of the system are presented and illustrated for the surveillance of guests inside a video-monitored building.

  6. Encapsulation of Hemin in Metal-Organic Frameworks for Catalyzing the Chemiluminescence Reaction of the H2O2-Luminol System and Detecting Glucose in the Neutral Condition.

    PubMed

    Luo, Fenqiang; Lin, Yaolin; Zheng, Liyan; Lin, Xiaomei; Chi, Yuwu

    2015-06-03

    Novel metal-organic frameworks (MOFs) based solid catalysts have been synthesized by encapsulating Hemin into the HKUST-1 MOF materials. These have been first applied in the chemiluminescence field with outstanding performance. The functionalized MOFs not only maintain an excellent catalytic activity inheriting from Hemin but also can be cyclically utilized as solid mimic peroxidases in the neutral condition. The synthesized Hemin@HKUST-1 composites have been used to develop practical sensors for H2O2 and glucose with wide response ranges and low detection limits. It was envisioned that catalyst-functionalized MOFs for chemiluminescence sensing would have promising applications in green, selective, and sensitive detection of target analytes in the future.

  7. Adaptive distributed outlier detection for WSNs.

    PubMed

    De Paola, Alessandra; Gaglio, Salvatore; Lo Re, Giuseppe; Milazzo, Fabrizio; Ortolani, Marco

    2015-05-01

    The paradigm of pervasive computing is gaining more and more attention nowadays, thanks to the possibility of obtaining precise and continuous monitoring. Ease of deployment and adaptivity are typically implemented by adopting autonomous and cooperative sensory devices; however, for such systems to be of any practical use, reliability and fault tolerance must be guaranteed, for instance by detecting corrupted readings amidst the huge amount of gathered sensory data. This paper proposes an adaptive distributed Bayesian approach for detecting outliers in data collected by a wireless sensor network; our algorithm aims at optimizing classification accuracy, time complexity and communication complexity, and also considering externally imposed constraints on such conflicting goals. The performed experimental evaluation showed that our approach is able to improve the considered metrics for latency and energy consumption, with limited impact on classification accuracy.

  8. Acknowledged Dependence and the Virtues of Perinatal Hospice

    PubMed Central

    Cobb, Aaron D.

    2016-01-01

    Prenatal screening can lead to the detection and diagnosis of significantly life-limiting conditions affecting the unborn child. Recognizing the difficulties facing parents who decide to continue the pregnancy, some have proposed perinatal hospice as a new modality of care. Although the medical literature has begun to devote significant attention to these practices, systematic philosophical reflection on perinatal hospice has been relatively limited. Drawing on Alasdair MacIntyre’s account of the virtues of acknowledged dependence, I contend that perinatal hospice manifests and facilitates virtues essential to living well with human dependency and vulnerability. For this reason, perinatal hospice deserves broad support within society. PMID:26661051

  9. Visual detection of glial cell line-derived neurotrophic factor based on a molecular translator and isothermal strand-displacement polymerization reaction.

    PubMed

    Zhang, Li-Yong; Xing, Tao; Du, Li-Xin; Li, Qing-Min; Liu, Wei-Dong; Wang, Ji-Yue; Cai, Jing

    2015-01-01

    Glial cell line-derived neurotrophic factor (GDNF) is a small protein that potently promotes the survival of many types of neurons. Detection of GDNF is vital to monitoring the survival of sympathetic and sensory neurons. However, the specific method for GDNF detection is also un-discovered. The purpose of this study is to explore the method for protein detection of GDNF. A novel visual detection method based on a molecular translator and isothermal strand-displacement polymerization reaction (ISDPR) has been proposed for the detection of GDNF. In this study, a molecular translator was employed to convert the input protein to output deoxyribonucleic acid signal, which was further amplified by ISDPR. The product of ISDPR was detected by a lateral flow biosensor within 30 minutes. This novel visual detection method based on a molecular translator and ISDPR has very high sensitivity and selectivity, with a dynamic response ranging from 1 pg/mL to 10 ng/mL, and the detection limit was 1 pg/mL of GDNF. This novel visual detection method exhibits high sensitivity and selectivity, which is very simple and universal for GDNF detection to help disease therapy in clinical practice.

  10. Parental feeding practices associated with children's eating and weight: What are parents of toddlers and preschool children doing?

    PubMed

    Russell, Catherine Georgina; Haszard, Jillian J; Taylor, Rachael W; Heath, Anne-Louise M; Taylor, Barry; Campbell, Karen J

    2018-05-26

    Parental feeding practices are associated with children's eating behaviours and weight, yet current use of such practices lacks detailed description. This limits our understanding of which behaviours to target to promote healthy growth. We explored the frequency with which a range of parental feeding practices occurs in mothers of toddler and preschool children. Combined data from four Australasian trials of healthy feeding and growth were utilized, each using the Comprehensive Feeding Practices Questionnaire (CFPQ). Data were included from mothers of toddlers (1.3-2 years; n = 1344) and preschool children (4-6 years; n = 795). Means and standard deviations for each CFPQ dimension were calculated for the two age groups. Scores were categorised by frequency, and percentages in each category calculated. Linear regression analysis determined associations between socio-demographics and feeding practices. In both age groups, mothers reported extensive use of some CFPQ dimensions including modelling, encouraging balance and variety, and healthy food environment (between 84% and 100% reported using these practices 'usually' to 'often'). Greater variation existed for other practices including pressure to eat and restriction for health. Food as a reward and pressure to eat were used more with preschool children (M = 2.5, SD = 1.0 and M = 3.1 SD = 0.9) than with toddlers (M = 1.7, SD = 0.8 and M = 2.5 SD = 0.9). For both age groups, mothers' age, education, SEP and BMI category, or the child's BMI, sex, or age predicted use of some feeding practices. Feeding practices such as modelling and providing a healthy food environment are important, but interventions are unlikely to detect effects as most parents report following best practice. In contrast, given greater variability in reported use of other feeding practices like pressure to eat and restriction for health these constructs may be more likely to detect change. Copyright © 2018. Published by Elsevier Ltd.

  11. A practical tissue sampling method using ordinary paper for molecular detection of infectious bursal disease virus RNA by RT-PCR.

    PubMed

    Maw, Min Thein; Yamaguchi, Tsuyoshi; Kasanga, Christopher J; Terasaki, Kaori; Fukushi, Hideto

    2006-12-01

    A practical sampling method for bursal tissue using ordinary paper for molecular diagnosis of infectious bursal disease (IBD) was established. IBD virus-infected bursa was directly smeared on chromatography paper, filter paper, or stationery copy paper and was then fixed with absolute ethanol, Tris-HCl-saturated phenol, or phenol:chloroform:isoamyl alcohol (25:24:1). Flinders Technology Associates (FTA) card, which is designed for the collection of biological samples for molecular detection, was also used. After storage at 37 C for up to 30 days, total RNA directly extracted from the tissue fixed on the papers and FTA card were subjected to reverse transcriptase-polymerase chain reaction (RT-PCR) for detection of IBD virus (IBDV) RNA. In addition, the ability of each chemical used in the fixation and the FTA card to inactivate IBDV was evaluated. Regardless of the paper quality, storage period, and fixation method, IBDV RNA was consistently detected in all of the samples. IBDV in the bursal tissue was inactivated with phenol but not with ethanol or the unknown chemicals in FTA card. These results show that ordinary papers sustain the viral RNA, as does FTA card, but phenol fixation is superior to FTA card in inactivating IBDV. The new sampling method using ordinary paper with phenol fixation is safe, inexpensive, simple, and easy, and is thus suitable for conducting a global survey of IBD even where laboratory resources are limited. This practical method should contribute to the control of IBD worldwide.

  12. Development of a rapid assay for the diagnosis of Myxobolus cerebralis in fish and oligochaetes using loop-mediated isothermal amplification.

    PubMed

    El-Matbouli, M; Soliman, H

    2005-09-01

    A loop-mediated isothermal amplification assay was developed for the rapid detection of Myxobolus cerebralis in both fish and oligochaete hosts. The assay was optimized to amplify parasitic DNA by incubation with Bst DNA polymerase and a set of six specially constructed primers at 65 degrees C for 60 min. The amplification products were detected visually using SYBR Green I dye which gave identical results to gel electrophoresis analysis. Parasite DNA was detected from infected oligochaetes, and from the anal fin, caudal fin, dorsal fin and operculum of clinically infected fish. This 'Myxo-LAMP' assay has a detection limit similar to that of a polymerase chain reaction assay (10(-6)), but is more rapid and only requires a water bath for amplification and is therefore practical for simple and rapid diagnosis of infected tissue.

  13. SWAN - Detection of explosives by means of fast neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.

    2016-10-01

    In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project "Accelerators & Detectors" (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.

  14. Circulating tumor DNA as a liquid biopsy target for detection of pancreatic cancer

    PubMed Central

    Takai, Erina; Yachida, Shinichi

    2016-01-01

    Most pancreatic cancer patients present with advanced metastatic disease, resulting in extremely poor 5-year survival, mainly because of the lack of a reliable modality for early detection and limited therapeutic options for advanced disease. Therefore, there is a need for minimally-invasive diagnostic tools for detecting pancreatic cancer at an early stage, when curative surgery and also novel therapeutic approaches including precision medicine may be feasible. The “liquid biopsy” addresses these unmet clinical needs based on the concept that simple peripheral blood sampling and detection of circulating tumor DNA (ctDNA) could provide diagnostic information. In this review, we provide an overview of the current status of blood-based tests for diagnosis of pancreatic cancer and the potential utility of ctDNA for precision medicine. We also discuss challenges that remain to be addressed in developing practical ctDNA-based liquid biopsy approaches for early diagnosis of pancreatic cancer. PMID:27784960

  15. Circulating tumor DNA as a liquid biopsy target for detection of pancreatic cancer.

    PubMed

    Takai, Erina; Yachida, Shinichi

    2016-10-14

    Most pancreatic cancer patients present with advanced metastatic disease, resulting in extremely poor 5-year survival, mainly because of the lack of a reliable modality for early detection and limited therapeutic options for advanced disease. Therefore, there is a need for minimally-invasive diagnostic tools for detecting pancreatic cancer at an early stage, when curative surgery and also novel therapeutic approaches including precision medicine may be feasible. The "liquid biopsy" addresses these unmet clinical needs based on the concept that simple peripheral blood sampling and detection of circulating tumor DNA (ctDNA) could provide diagnostic information. In this review, we provide an overview of the current status of blood-based tests for diagnosis of pancreatic cancer and the potential utility of ctDNA for precision medicine. We also discuss challenges that remain to be addressed in developing practical ctDNA-based liquid biopsy approaches for early diagnosis of pancreatic cancer.

  16. A rapid, naked-eye detection of hypochlorite and bisulfite using a robust and highly-photostable indicator dye Quinaldine Red in aqueous medium

    NASA Astrophysics Data System (ADS)

    Dutta, Tanoy; Chandra, Falguni; Koner, Apurba L.

    2018-02-01

    A ;naked-eye; detection of health hazardous bisulfite (HSO3-) and hypochlorite (ClO-) using an indicator dye (Quinaldine Red, QR) in a wide range of pH is demonstrated. The molecule contains a quinoline moiety linked to an N,N-dimethylaniline moiety with a conjugated double bond. Treatment of QR with HSO3- and ClO-, in aqueous solution at near-neutral pH, resulted in a colorless product with high selectivity and sensitivity. The detection limit was 47.8 μM and 0.2 μM for HSO3- and ClO- respectively. However, ClO- was 50 times more sensitive and with 2 times faster response compared to HSO3-. The detail characterization and related analysis demonstrate the potential of QR for a rapid, robust and highly efficient colorimetric sensor for the practical applications to detect hypochlorite in water samples.

  17. Affinity Biosensors for Detection of Mycotoxins in Food.

    PubMed

    Evtugyn, Gennady; Subjakova, Veronika; Melikishvili, Sopio; Hianik, Tibor

    2018-01-01

    This chapter reviews recent achievements in methods of detection of mycotoxins in food. Special focus is on the biosensor technology that utilizes antibodies and nucleic acid aptamers as receptors. Development of biosensors is based on the immobilization of antibodies or aptamers onto various conventional supports like gold layer, but also on nanomaterials such as graphene oxide, carbon nanotubes, and quantum dots that provide an effective platform for achieving high sensitivity of detection using various physical methods, including electrochemical, mass sensitive, and optical. The biosensors developed so far demonstrate high sensitivity typically in subnanomolar limit of detection. Several biosensors have been validated in real samples. The sensitivity of biosensors is similar and, in some cases, even better than traditional analytical methods such as ELISA or chromatography. We believe that future trends will be focused on improving biosensor properties toward practical application in food industry. © 2018 Elsevier Inc. All rights reserved.

  18. Nitrogen doped carbon nanodots as fluorescent probes for selective detection and quantification of Ferric(III) ions

    NASA Astrophysics Data System (ADS)

    Chin, Suk-Fun; Tan, Shao-Chien; Pang, Suh-Cem; Ng, Sing-Muk

    2017-11-01

    Nitrogen (N) doped carbon dots (N-CDs) that showed blue fluorescence with quantum yield (QY) of 12.25% were synthesized by one step microwave irradiation of lysine in ortho-phosphoric acid at 1000 W for 5 min. The as-synthesized N-CDs were successfully explored as fluorescent probes for selective detection of ferric (Fe3+) ions in aqueous condition with a linear range from 0.2 to 5.0 mM and a detection limit of 0.074 mM ± 0.081 (S/N = 3). The N-CDs exhibited high selectivity towards the detection of Fe3+ ions even in the presence of interfering ions. The N-CDs also demonstrated the potential of practical application for determining of Fe3+ ions concentration in real samples with high recovery rate and low relative standard deviation error.

  19. Cobalt oxide nanosheets wrapped onto nickel foam for non-enzymatic detection of glucose

    NASA Astrophysics Data System (ADS)

    Meng, Shangjun; Wu, Meiyan; Wang, Qian; Dai, Ziyang; Si, Weili; Huang, Wei; Dong, Xiaochen

    2016-08-01

    Ultra-sensitive and highly selective detection of glucose is essential for the clinical diagnosis of diabetes. In this paper, an ultra-sensitive glucose sensor was successfully fabricated based on cobalt oxide (Co3O4) nanosheets directly grown on nickel foam through a simple hydrothermal method. Characterizations indicated that the Co3O4 nanosheets are completely and uniformly wrapped onto the surface of nickel foam to form a three-dimensional heterostructure. The resulting self-standing electrochemical electrode presents a high performance for the non-enzymatic detection of glucose, including short response time (<10 s), ultra-sensitivity (12.97 mA mM-1 cm-2), excellent selectivity and low detection limit (0.058 μM, S/N = 3). These results indicate that Co3O4 nanosheets wrapped onto nickel foam are a low-cost, practical, and high performance electrochemical electrode for bio sensing.

  20. High effective algorithm of the detection and identification of substance using the noisy reflected THz pulse

    NASA Astrophysics Data System (ADS)

    Trofimov, Vyacheslav A.; Varentsova, Svetlana A.; Trofimov, Vladislav V.; Tikhomirov, Vasily V.

    2015-08-01

    Principal limitations of the standard THz-TDS method for the detection and identification are demonstrated under real conditions (at long distance of about 3.5 m and at a high relative humidity more than 50%) using neutral substances thick paper bag, paper napkins and chocolate. We show also that the THz-TDS method detects spectral features of dangerous substances even if the THz signals were measured in laboratory conditions (at distance 30-40 cm from the receiver and at a low relative humidity less than 2%); silicon-based semiconductors were used as the samples. However, the integral correlation criteria, based on SDA method, allows us to detect the absence of dangerous substances in the neutral substances. The discussed algorithm shows high probability of the substance identification and a reliability of realization in practice, especially for security applications and non-destructive testing.

  1. Assessing access to MRI of patients with magnetic resonance-conditional pacemaker and implantable cardioverter defibrillator systems: the Really ProMRI study design.

    PubMed

    Maglia, Giampiero; Curnis, Antonio; Brieda, Marco; Anaclerio, Matteo; Caccavo, Vincenzo; Bonfanti, Paolo; Melissano, Donato; Caravati, Fabrizio; Giovene, Lisa; Gargaro, Alessio

    2015-10-01

    Despite the fact that magnetic resonance (MR)-conditional pacemaker and lead systems have been introduced more than 5 years ago, it is still not clear whether they have actually facilitated the access of pacemaker patients to this important diagnostic tool. Factors limiting MR scans in daily practice in patients with MR-conditional cardiac implantable electronic device (CIED) systems may be related to organizational, cultural and sometimes legal aspects. The Really ProMRI registry is an ongoing survey designed to assess the annual rate of MR examinations in patients with MR-conditional implants, with either pacemakers or implantable cardioverter defibrillators, and to detect the main factors limiting MRI. The primary endpoint of the Really ProMRI registry is to assess the current access to MRI of patients with MR-conditional pacemaker or implantable cardioverter defibrillator systems during normal practice. Data in the literature reported a 17% annual incidence of medical conditions requiring MRI in CIED patients. The Really ProMRI registry has been designed to detect 4.5% absolute difference with an 80% statistical power, by recruiting 600 patients already implanted with MR-conditional CIED implant. Patients will be followed up for 1 year, during which they will be asked to refer any prescription, execution or denial of an MR examination by patient questionnaires and original source documents. The ongoing Really ProMRI registry will assess the actual rate of and factors limiting the access to MRI for patients with MR-conditional CIEDs.

  2. How valuable is physical examination of the cardiovascular system?

    PubMed

    Elder, Andrew; Japp, Alan; Verghese, Abraham

    2016-07-27

    Physical examination of the cardiovascular system is central to contemporary teaching and practice in clinical medicine. Evidence about its value focuses on its diagnostic accuracy and varies widely in methodological quality and statistical power. This makes collation, analysis, and understanding of results difficult and limits their application to daily clinical practice. Specific factors affecting interpretation and clinical application include poor standardisation of observers' technique and training, the study of single signs rather than multiple signs or signs in combination with symptoms, and the tendency to compare physical examination directly with technological aids to diagnosis rather than explore diagnostic strategies that combine both. Other potential aspects of the value of physical examination, such as cost effectiveness or patients' perceptions, are poorly studied. This review summarises the evidence for the clinical value of physical examination of the cardiovascular system. The best was judged to relate to the detection and evaluation of valvular heart disease, the diagnosis and treatment of heart failure, the jugular venous pulse in the assessment of central venous pressure, and the detection of atrial fibrillation, peripheral arterial disease, impaired perfusion, and aortic and carotid disease. Although technological aids to diagnosis are likely to become even more widely available at the point of care, the evidence suggests that further research into the value of physical examination of the cardiovascular system is needed, particularly in low resource settings and as a potential means of limiting inappropriate overuse of technological aids to diagnosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Comparison of direct and heterodyne detection optical intersatellite communication links

    NASA Technical Reports Server (NTRS)

    Chen, C. C.; Gardner, C. S.

    1987-01-01

    The performance of direct and heterodyne detection optical intersatellite communication links are evaluated and compared. It is shown that the performance of optical links is very sensitive to the pointing and tracking errors at the transmitter and receiver. In the presence of random pointing and tracking errors, optimal antenna gains exist that will minimize the required transmitter power. In addition to limiting the antenna gains, random pointing and tracking errors also impose a power penalty in the link budget. This power penalty is between 1.6 to 3 dB for a direct detection QPPM link, and 3 to 5 dB for a heterodyne QFSK system. For the heterodyne systems, the carrier phase noise presents another major factor of performance degradation that must be considered. In contrast, the loss due to synchronization error is small. The link budgets for direct and heterodyne detection systems are evaluated. It is shown that, for systems with large pointing and tracking errors, the link budget is dominated by the spatial tracking error, and the direct detection system shows a superior performance because it is less sensitive to the spatial tracking error. On the other hand, for systems with small pointing and tracking jitters, the antenna gains are in general limited by the launch cost, and suboptimal antenna gains are often used in practice. In which case, the heterodyne system has a slightly higher power margin because of higher receiver sensitivity.

  4. Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Najafi, Massieh; Auslander, David M.; Bartlett, Peter L.

    2010-05-30

    Many studies have shown that energy savings of five to fifteen percent are achievable in commercial buildings by detecting and correcting building faults, and optimizing building control systems. However, in spite of good progress in developing tools for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most approaches use numerical filtering or parameter estimation methods to compare data from energy meters and building sensors to predictions from mathematical or statistical models. They are effective when models are relatively accurate and data contain few errors. In this paper, we address the case where models aremore » imperfect and data are variable, uncertain, and can contain error. We apply a Bayesian updating approach that is systematic in managing and accounting for most forms of model and data errors. The proposed method uses both knowledge of first principle modeling and empirical results to analyze the system performance within the boundaries defined by practical constraints. We demonstrate the approach by detecting faults in commercial building air handling units. We find that the limitations that exist in air handling unit diagnostics due to practical constraints can generally be effectively addressed through the proposed approach.« less

  5. Practical application of a patient satisfaction survey.

    PubMed

    Margo, K L; Margo, G M

    1990-01-01

    Patient satisfaction surveys are a practical method for studying one aspect of quality of care in an HMO. This report details the use of a patient satisfaction survey for this purpose. The focus is on the instrument chosen and the type of analyses carried out. Despite the interest and potential usefulness of the data obtained, the organizational response to the study can be the rate-limiting factor for using the findings. In general, the method can be used for periodic monitoring and as a valid method for detecting or confirming suspected trouble spots in the system. To be successful, the data must be interpreted in the spirit of a shared commitment to quality care.

  6. Revisiting Antipsychotic-induced Akathisia: Current Issues and Prospective Challenges

    PubMed Central

    Salem, Haitham; Nagpal, Caesa; Pigott, Teresa; Teixeira, Antonio Lucio

    2017-01-01

    Background: Akathisia continues to be a significant challenge in current neurological and psychiatric practice. Prompt and accurate detection is often difficult and there is a lack of consensus concerning the neurobiological basis of akathisia. No definitive treatment has been established for akathisia despite numerous preclinical and clinical studies. Method: We reviewed antipsychotic-induced akathisia including its clinical presentation, proposed underlying pathophysiology, current and under investigation therapeutic strategies. Conclusion: Despite the initial promise that second generation antipsychotics would be devoid of akathisia effects, this has not been confirmed. Currently, there are limited therapeutic options for the clinical practice and the evidence supporting the most widely used treatments (beta blockers, anticholinergic drugs) is still absent or inconsistent. PMID:27928948

  7. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection

    NASA Astrophysics Data System (ADS)

    Zang, Yaping; Zhang, Fengjiao; Huang, Dazhen; Gao, Xike; di, Chong-An; Zhu, Daoben

    2015-03-01

    The utilization of organic devices as pressure-sensing elements in artificial intelligence and healthcare applications represents a fascinating opportunity for the next-generation electronic products. To satisfy the critical requirements of these promising applications, the low-cost construction of large-area ultra-sensitive organic pressure devices with outstanding flexibility is highly desired. Here we present flexible suspended gate organic thin-film transistors (SGOTFTs) as a model platform that enables ultra-sensitive pressure detection. More importantly, the unique device geometry of SGOTFTs allows the fine-tuning of their sensitivity by the suspended gate. An unprecedented sensitivity of 192 kPa-1, a low limit-of-detection pressure of <0.5 Pa and a short response time of 10 ms were successfully realized, allowing the real-time detection of acoustic waves. These excellent sensing properties of SGOTFTs, together with their advantages of facile large-area fabrication and versatility in detecting various pressure signals, make SGOTFTs a powerful strategy for spatial pressure mapping in practical applications.

  8. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection

    PubMed Central

    Zang, Yaping; Zhang, Fengjiao; Huang, Dazhen; Gao, Xike; Di, Chong-an; Zhu, Daoben

    2015-01-01

    The utilization of organic devices as pressure-sensing elements in artificial intelligence and healthcare applications represents a fascinating opportunity for the next-generation electronic products. To satisfy the critical requirements of these promising applications, the low-cost construction of large-area ultra-sensitive organic pressure devices with outstanding flexibility is highly desired. Here we present flexible suspended gate organic thin-film transistors (SGOTFTs) as a model platform that enables ultra-sensitive pressure detection. More importantly, the unique device geometry of SGOTFTs allows the fine-tuning of their sensitivity by the suspended gate. An unprecedented sensitivity of 192 kPa−1, a low limit-of-detection pressure of <0.5 Pa and a short response time of 10 ms were successfully realized, allowing the real-time detection of acoustic waves. These excellent sensing properties of SGOTFTs, together with their advantages of facile large-area fabrication and versatility in detecting various pressure signals, make SGOTFTs a powerful strategy for spatial pressure mapping in practical applications. PMID:25872157

  9. A compact and portable optofluidic device for detection of liquid properties and label-free sensing

    NASA Astrophysics Data System (ADS)

    Lahoz, F.; Martín, I. R.; Walo, D.; Gil-Rostra, J.; Yubero, F.; Gonzalez-Elipe, A. R.

    2017-06-01

    Optofluidic lasers have been widely investigated over the last few years mainly because they can be easily integrated in sensor devices. However, high power pulse lasers are required as excitation sources, which, in practice, limit the portability of the system. Trying to overcome some of these limitations, in this paper we propose the combined use of a small CW laser with a Fabry-Perot optofluidic planar microcavity showing high sensitivity and versatility for detection of liquid properties and label-free sensing. Firstly, a fluorescein solution in ethanol is used to demonstrate the high performances of the FP microcavity as a temperature sensor both in the laser (high pump power above laser threshold) and in the fluorescence (low pump power) regimes. A shift in the wavelength of the resonant cavity modes is used to detect changes in the temperature and our results show that high sensitivities could be already obtained using cheap and portable CW diode lasers. In the second part of the paper, the demonstration of this portable device for label-free sensing is illustrated under low CW pumping. The wavelength positions of the optofluidic resonant modes are used to detect glucose concentrations in water solutions using a protein labelled with a fluorescent dye as the active medium.

  10. Effects of different excitation waveforms on detection and characterisation of delamination in PV modules by active infrared thermography

    NASA Astrophysics Data System (ADS)

    Sinha, Archana; Gupta, Rajesh

    2017-10-01

    Delamination significantly affects the performance and reliability of photovoltaic (PV) modules. Recently, an active infrared thermography approach using step heating has been exploited for the detection and characterisation of delamination in PV modules. However, step heating takes longer observation time and causes overheating problems. This paper presents the effects of different thermal excitation waveforms namely rectangular, half-sine and short pulse, on the detection and characterisation of delamination in PV module by experiments and simulations. For simulation, a 3-dimensional electro-thermal model of heat conduction, based on resistance-capacitance network approach, has been exploited to study the variation in maximum thermal contrast and peak contrast time with the delamination thickness and heating parameters. Results show that the rectangular waveform provides better detection of delamination due to higher absolute contrast, while the half-sine waveform allows better characterisation of delamination in the PV modules with low-cost and low-power heat source. The high-energy short pulse enabled quick visualisation of delamination, but has limited practical implementation. The advantages and limitations of each waveform have been highlighted to assess the specific requirement for appropriate choice in the non-destructive thermographic inspection of delamination in PV modules at the manufacturing units or outdoor fields.

  11. Real-time PCR assay for the detection and quantification of Legionella pneumophila in environmental water samples: utility for daily practice.

    PubMed

    Morio, Florent; Corvec, Stéphane; Caroff, Nathalie; Le Gallou, Florence; Drugeon, Henri; Reynaud, Alain

    2008-07-01

    We developed a quantitative real-time PCR assay targeting the mip gene of Legionella pneumophila for a prospective study from September 2004 to April 2005. It was compared with a standard culture method (French guideline AFNOR T90-431), analysing 120 water samples collected to monitor the risk related to Legionellae at Nantes hospital and to investigate a case of legionellosis acquired from hospital environment. Samples from six distinct water distribution systems were analysed by DNA extraction, amplification and detection with specific primers and FRET probes. The detection limit was 100 genomic units of L. pneumophila per liter (GU/l), the positivity threshold about 600 GU/l and the quantification limit 800 GU/l. PCR results were divided into three groups: negative (n=63), positive but non-quantifiable (n=22) or positive (n=35). PCR showed higher sensitivity than culture, whereas four culture-positive samples appeared negative by PCR (PCR inhibitor detected for two of them). Although no correlation was observed between both methods and real-time PCR cannot substitute for the reference method, it represents an interesting complement. Its sensitivity, reproducibility and rapidity appear particularly interesting in epidemic contexts in order to identify the source of contamination or to evaluate critical points of contamination in water distribution systems.

  12. Novel and remarkable enhanced-fluorescence system based on gold nanoclusters for detection of tetracycline.

    PubMed

    Yang, Xiaoming; Zhu, Shanshan; Dou, Yao; Zhuo, Yan; Luo, Yawen; Feng, Yuanjiao

    2014-05-01

    Tetracycline and Eu(3+), while coexisting, usually appear as a complex by chelating. This complex shows low fluorescence intensity, leading to its limitation of analytical goals. Gold nanoclusters (AuNCs), emerging as novel nano-material, are attracting increasing attentions in multiple fields. Herein, gold nanoclusters first function as a fluorescence-enhanced reagent rather than a conventional fluorescent-probe, and a dramatic enhanced-fluorescence system was built based on Eu(3+)-Tetracycline complex (EuTC) by introducing gold nanoclusters. Simultaneously, three types of gold nanoclusters were employed for exploring various conditions likely affecting the system, which demonstrate that no other gold nanoclusters than DNA-templated gold nanoclusters enormously caused fluorescence-enhancement of EuTC. Moreover, this enhanced-fluorescence system permitted available detection of tetracycline (TC) in a linear range of 0.01-5 μM, with a detection limit of 4 nM at a signal-to-noise ratio of 3. Significantly, the practicality of this method for detection of TC in human urine and milk samples was validated, demonstrating its advantages of simplicity, sensitivity and low cost. Interestingly, this system described here is probably promising for kinds of applications based on its dramatically enhanced-fluorescence. © 2013 Published by Elsevier B.V.

  13. Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.

    PubMed

    Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J

    2015-07-01

    The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide

    PubMed Central

    Koudelkova, Zuzana; Syrovy, Tomas; Ambrozova, Pavlina; Moravec, Zdenek; Kubac, Lubomir; Hynek, David; Adam, Vojtech

    2017-01-01

    In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 µg·L−1 for Zn(II), 3 and 10 µg·L−1 for Cd(II), 3 and 10 µg·L−1 for Pb(II), 3 and 10 µg·L−1 for Cu(II), and 3 and 10 µg·L−1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 µg·L−1 for Zn(II), 25 µg·L−1 for Cd(II), 3 µg·L−1 for Pb(II) and 3 µg·L−1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters. PMID:28792450

  15. Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide.

    PubMed

    Koudelkova, Zuzana; Syrovy, Tomas; Ambrozova, Pavlina; Moravec, Zdenek; Kubac, Lubomir; Hynek, David; Richtera, Lukas; Adam, Vojtech

    2017-08-09

    In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 µg·L -1 for Zn(II), 3 and 10 µg·L -1 for Cd(II), 3 and 10 µg·L -1 for Pb(II), 3 and 10 µg·L -1 for Cu(II), and 3 and 10 µg·L -1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 µg·L -1 for Zn(II), 25 µg·L -1 for Cd(II), 3 µg·L -1 for Pb(II) and 3 µg·L -1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.

  16. A digital boxcar integrator for IMS spectra

    NASA Technical Reports Server (NTRS)

    Cohen, Martin J.; Stimac, Robert M.; Wernlund, Roger F.; Parker, Donald C.

    1995-01-01

    When trying to detect or quantify a signal at or near the limit of detectability, it is invariably embeded in the noise. This statement is true for nearly all detectors of any physical phenomena and the limit of detectability, hopefully, occurs at very low signal-to-noise levels. This is particularly true of IMS (Ion Mobility Spectrometers) spectra due to the low vapor pressure of several chemical compounds of great interest and the small currents associated with the ionic detection process. Gated Integrators and Boxcar Integrators or Averagers are designed to recover fast, repetitive analog signals. In a typical application, a time 'Gate' or 'Window' is generated, characterized by a set delay from a trigger or gate pulse and a certain width. A Gated Integrator amplifies and integrates the signal that is present during the time the gate is open, ignoring noise and interference that may be present at other times. Boxcar Integration refers to the practice of averaging the output of the Gated Integrator over many sweeps of the detector. Since any signal present during the gate will add linearly, while noise will add in a 'random walk' fashion as the square root of the number of sweeps, averaging N sweeps will improve the 'Signal-to-Noise Ratio' by a factor of the square root of N.

  17. An ATMND/SGI based label-free and fluorescence ratiometric aptasensor for rapid and highly sensitive detection of cocaine in biofluids.

    PubMed

    Wang, Jiamian; Song, Jie; Wang, Xiuyun; Wu, Shuo; Zhao, Yanqiu; Luo, Pinchen; Meng, Changgong

    2016-12-01

    A label-free ratiometric fluorescence aptasensor has been developed for the rapid and sensitive detection of cocaine in complex biofluids. The fluorescent aptasensor is composed of a non-labeled GC-38 cocaine aptamer which serves as a basic sensing unit and two fluorophores, 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and SYBR Green I (SGI) which serves as a signal reporter and a build-in reference, respectively. The detection principle is based on a specific cocaine mediated ATMND displacement reaction and the corresponding change in the fluorescence ratio of ATMND to SGI. Due to the high affinity of the non-labeled aptamer, the good precision originated from the ratiometric method, and the good fluorescence quantum yield of the fluorophore, the aptasensor shows good analytical performance with respect to cocaine detection. Under optimal conditions, the aptasensor shows a linear range of 0.10-10μM and a low limit of detection of 56nM, with a fast response of 20s. The low limit of detection is comparable to most of the fluorescent aptasensors with signal amplification strategies and much lower than all of the unamplified cocaine aptasensors. Practical sample analysis in a series of complex biofluids, including urine, saliva and serum, also indicates the good precision, stability, and high sensitivity of the aptasensor, which may have great potential for the point-of-care screening of cocaine in complex biofluids. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Medicolegal affairs. International Academy of Cytology Task Force summary. Diagnostic Cytology Towards the 21st Century: An International Expert Conference and Tutorial.

    PubMed

    Frable, W J; Austin, R M; Greening, S E; Collins, R J; Hillman, R L; Kobler, T P; Koss, L G; Mitchell, H; Perey, R; Rosenthal, D L; Sidoti, M S; Somrak, T M

    1998-01-01

    Increasing litigation over alleged false negative cervical cytologic (CC) smears threatens the viability of this test for cervical cancer detection. The problem appears to be largely American but is beginning to appear in some other countries. In the vast majority of cases there is either a settlement or jury verdict for the plaintiff based largely on the testimony of expert witnesses. Cases are judged on an individual basis without significant consideration of the general performance of the CC smear in laboratories operating in compliance with a wide array of laboratory regulations and with documented and comprehensive quality control practices in place. It is acknowledged that there are problem laboratories and cytology practitioners. There is an emerging issue of automated preparation and screening devices and issues of informed patient consent. Cytology professionals have done an extraordinary and commendable job of educating the public about the benefits of the CC smear. We have been less successful and conscientious about explaining and defining the limitations of the CC test. There is a need for public and professional education as to the benefits and limitations of the CC smear for cervical cancer detection. The process suggested is to work with women's groups, public health agencies, government agencies, and state and national legislatures and to coordinate professional committees working on liability issues. Contextual information could be included with the CC smear report to indicate that a negative report confers a low probability of developing cervical cancer. It is suggested that appropriate language and a menu of statements be developed. Increased efforts should be directed to physician education with respect to informed consent concerning the benefits and limitations of CC smear testing and the application of new technology to improve smear accuracy. The process should include development of appropriate statements on the use of alternative technology. The profession should develop "process guidelines" for review of CC smears in the context of possible litigation, including standardized methods for blind slide review of smears that reduce or eliminate context and outcome bias. It is suggested that review panels be anonymous, that the process be standardized and that there be limitations on liability for participating organizations. Professional cytopathology and pathology societies should formulate acceptable guidelines for expert witnesses. The standards should be applicable to both defendant and plaintiff experts. All materials to the extent practical, including consultant opinions, should be available for peer review. Professional cytopathology and pathology societies should monitor expert testimony for objectivity and scientific accuracy. For the near future, litigation will continue to focus on false negative CC smears on a case-by-case basis. Laboratories and individuals can reduce the risk of malpractice liability by directing their attention to proactive quality control and quality assurance methods. In the final analysis, consumer education about the benefits and limitations of the test is key to limiting malpractice claims. To stem the tide of continued medicolegal challenges to the integrity of cytology practice, the cytology community has now focused its efforts on developing and utilizing standards that convey to patients, attorneys and cytologists the contemporary status of and reasonable expectations for the practice of cytology. Guidelines such as those for uniform reporting terminology and clinical management of cervical abnormalities form the basis of cytology practice standards on which legal standards of practice can be based. Consensus conference reports, clinical management trials and scientifically valid studies of false negative rates that analyze the type, frequency and cause of missed cases represent sounder methods of establishing defensible

  19. Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma.

    PubMed

    Wright, Chadwick L; Maly, Joseph J; Zhang, Jun; Knopp, Michael V

    2017-01-01

    PET with fluorodeoxyglucose F 18 ( 18 F FDG-PET) is a meaningful biomarker for the detection, targeted biopsy, and treatment of lymphoma. This article reviews the evolution of 18 F FDG-PET as a putative biomarker for lymphoma and addresses the current capabilities, challenges, and opportunities to enable precision medicine practices for lymphoma. Precision nuclear medicine is driven by new imaging technologies and methodologies to more accurately detect malignant disease. Although quantitative assessment of response is limited, such technologies will enable a more precise metabolic mapping with much higher definition image detail and thus may make it a robust and valid quantitative response assessment methodology. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Time-dependent local density measurements in unsteady flows

    NASA Technical Reports Server (NTRS)

    Mckenzie, R. L.; Monson, D. J.; Exberger, R. J.

    1979-01-01

    A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

  1. A follow up study of occupational exposure to 4,4'-methylene-bis(2-chloroaniline) (MbOCA) and isocyanates in polyurethane manufacture in the UK.

    PubMed

    Keen, C; Coldwell, M; McNally, K; Baldwin, P; McAlinden, J; Cocker, J

    2012-08-13

    This is a follow up survey of exposure to 4,4'-methylene-bis(2-chloroaniline) (MbOCA) and isocyanates in the UK polyurethane industry. Urine samples (n=446) were collected from 90 different workers. MbOCA levels were below the limit of detection in 170 samples and 26 were above the UK Biological Monitoring Guidance Value (BMGV) of 15 μmol MbOCA/mol creatinine. Detailed advice and guidance was given to each workplace at the end of the survey in 2008 and the 90% value reduced from 10 to 3 μmol MbOCA/mol creatinine in samples collected since. There was a positive correlation between glove contamination and urinary MbOCA and levels were dependent upon individual working practices especially how gloves were used. Of the 446 samples analysed for urinary metabolites of toluene diisocyanate 280 were below the detection limit and 126 were above the BMGV (1 μmol/mol creatinine). Of the 326 urine samples that were analysed for metabolites of methylenediphenyl diisocyanate, 270 were below the detection limit and 13 were above the BMGV for isocyanates. There was no correlation between urinary levels of isocyanates and MbOCA suggesting different routes of absorption, most likely inhalation and dermal respectively. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Some consideration for evaluation of structural integrity of aging aircraft

    NASA Astrophysics Data System (ADS)

    Terada, Hiroyuki; Asada, Hiroo

    The objective of this paper is to examine the achievement and the limitation of state-of-the-art of the methodology of damage tolerant design and the subjects to be solved for further improvement. The topics discussed are: the basic concept of full-scale fatigue testing, fracture mechanics applications, repair of detected damages, inspection technology, and determination of inspection intervals, reliability assessment for practical application, and the importance of various kinds of data acquisition.

  3. Mindfulness-based stress reduction teachers, practice characteristics, cancer incidence, and health: a nationwide ecological description.

    PubMed

    Robb, Sara Wagner; Benson, Kelsey; Middleton, Lauren; Meyers, Christine; Hébert, James R

    2015-02-14

    Studies have demonstrated the potential of the Mindfulness-Based Stress Reduction (MBSR) program to improve the condition of individuals with health outcomes such as hypertension, diabetes, and chronic pain; improve psychological well-being; reduce stress levels; and increase survival among cancer patients. To date, only one study has focused on the effect of long-term meditation on stress, showing a positive protective relationship. However, the relationship between meditation and cancer incidence remains unexplored. The objective of this study was to describe the state-level relationship between MBSR instructors and their practices and county-level health outcomes, including cancer incidence, in the United States. This ecologic study was performed using geospatial mapping and descriptive epidemiology of statewide MBSR characteristics and overall health, mental health state rankings, and age-adjusted cancer incidence rates. Weak to moderate state-level correlations between meditation characteristics and colorectal and cervical cancer incidence were detected, with states with more meditation (e.g., more MBSR teachers per population) correlated with a decreased cancer incidence. A negative correlation was detected between lung & bronchus cancer and years teaching MBSR only. Moderate positive correlations were detected between Hodgkin's Lymphoma and female breast cancer in relation to all meditation characteristics. Statistically significant correlations with moderate coefficients were detected for overall health ranks and all meditation characteristics, most strongly for total number of years teaching MBSR and total number of years of general meditation practice. Our analyses might suggest that a relationship exists between the total number of MBSR teachers per state and the total number of years of general meditation practice per state, and colorectal and cervical cancer incidence. Positive correlations were observed with overall health rankings. Despite this study's limitations, its findings could serve to generate hypotheses and to inform and motivate a new focus on meditation and stress reduction in relation to cancer incidence, with specific relevance to colorectal and cervical cancer.

  4. Captan and fenitrothion dissipation in field-treated cauliflowers and effect of household processing.

    PubMed

    Fernández-Cruz, María L; Barreda, Mercedes; Villarroya, Mercedes; Peruga, Arantzazu; Llanos, Susana; García-Baudín, José M

    2006-07-01

    Field trial studies have been performed with captan and fenitrothion on cauliflower to propose maximum residue limits and to study the dissipation of the pesticides. Residue levels have been determined at different times following good laboratory practice using gas chromatography with mass spectrometric detection. The behaviour of residue levels of these compounds after household processing has been analysed using gas chromatography with electron capture detection. Seven days after treatment, residue levels of captan could be detected, but not of fenitrothion. The half-lives of dissipation for captan and fenitrothion were calculated as 0.9 and 1.8 days respectively. Washing did not significantly affect the residual amounts of captan and fenitrothion observed in raw vegetables; however, after cooking, captan had degraded completely, whereas residue levels of fenitrothion were not modified significantly.

  5. SNaPshot and StripAssay as Valuable Alternatives to Direct Sequencing for KRAS Mutation Detection in Colon Cancer Routine Diagnostics

    PubMed Central

    Fariña Sarasqueta, Arantza; Moerland, Elna; de Bruyne, Hanneke; de Graaf, Henk; Vrancken, Tamara; van Lijnschoten, Gesina; van den Brule, Adriaan J.C.

    2011-01-01

    Although direct sequencing is the gold standard for KRAS mutation detection in routine diagnostics, it remains laborious, time consuming, and not very sensitive. Our objective was to evaluate SNaPshot and the KRAS StripAssay as alternatives to sequencing for KRAS mutation detection in daily practice. KRAS exon 2–specific PCR followed by sequencing or by a SNaPshot reaction was performed. For the StripAssay, a mutant-enriched PCR was followed by hybridization to KRAS-specific probes bound to a nitrocellulose strip. To test sensitivities, dilution series of mutated DNA in wild-type DNA were made. Additionally, direct sequencing and SNaPshot were evaluated in 296 colon cancer samples. Detection limits of direct sequencing, SNaPshot, and StripAssay were 20%, 10%, and 1% tumor cells, respectively. Direct sequencing and SNaPshot can detect all 12 mutations in KRAS codons 12 and 13, whereas the StripAssay detects 10 of the most frequent ones. Workload and time to results are comparable for SNaPshot and direct sequencing. SNaPshot is flexible and easy to multiplex. The StripAssay is less time consuming for daily laboratory practice. SNaPshot is more flexible and slightly more sensitive than direct sequencing. The clinical evaluation showed comparable performances between direct sequencing and SNaPshot. The StripAssay is rapid and an extremely sensitive assay that could be considered when few tumor cells are available. However, found mutants should be confirmed to avoid risk of false positives. PMID:21354055

  6. Radiologic evaluation of nonalcoholic fatty liver disease

    PubMed Central

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  7. Challenges in miniaturized automotive long-range lidar system design

    NASA Astrophysics Data System (ADS)

    Fersch, Thomas; Weigel, Robert; Koelpin, Alexander

    2017-05-01

    This paper discusses the current technical limitations posed on endeavors to miniaturize lidar systems for use in automotive applications and how to possibly extend those limits. The focus is set on long-range scanning direct time of flight LiDAR systems using APD photodetectors. Miniaturization evokes severe problems in ensuring absolute laser safety while maintaining the systems' performance in terms of maximum range, signal-to-noise ratio, detection probability, pixel density, or frame rate. Based on hypothetical but realistic specifications for an exemplary system the complete lidar signal path is calculated. The maximum range of the system is used as a general performance indicator. It is determined with the minimum signal-to-noise ratio required to detect an object. Various system parameters are varied to find their impact on the system's range. The reduction of the laser's pulse width and the right choice for the transimpedance amplifier's amplification have shown to be practicable measures to double the system's range.

  8. Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques

    NASA Astrophysics Data System (ADS)

    Vavrik, D.; Jakubek, J.; Jandejsek, I.; Krejci, F.; Kumpova, I.; Zemlicka, J.

    2015-04-01

    This work is focused on the development of instrumental radiographic methods for detection of delaminations in layered carbon fibre reinforced plastic composites used in the aerospace industry. The main limitation of current visualisation techniques is a very limited possibility to image so-called closed delaminations in which delaminated layers are in contact practically with no physical gap. In this contribution we report the development of innovative methods for closed delamination detection using an X-ray phase contrast technique for which the distance between delamination surfaces is not relevant. The approach is based on the energetic sensitivity of phase-enhanced radiography. Based on the applied methodology, we can distinguish both closed and open delamination. Further we have demonstrated the possibility to visualise open delaminations characterised by a physical gap between delaminated layers. This delamination type was successfully identified and visualized utilizing a high resolution and computed tomography table-top technique based on proper beam-hardening effect correction.

  9. External evaluation of the Dimension Vista 1500® intelligent lab system.

    PubMed

    Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne

    2012-09-01

    Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.

  10. Rapid Detection Methods for Asphalt Pavement Thicknesses and Defects by a Vehicle-Mounted Ground Penetrating Radar (GPR) System

    PubMed Central

    Dong, Zehua; Ye, Shengbo; Gao, Yunze; Fang, Guangyou; Zhang, Xiaojuan; Xue, Zhongjun; Zhang, Tao

    2016-01-01

    The thickness estimation of the top surface layer and surface layer, as well as the detection of road defects, are of great importance to the quality conditions of asphalt pavement. Although ground penetrating radar (GPR) methods have been widely used in non-destructive detection of pavements, the thickness estimation of the thin top surface layer is still a difficult problem due to the limitations of GPR resolution and the similar permittivity of asphalt sub-layers. Besides, the detection of some road defects, including inadequate compaction and delamination at interfaces, require further practical study. In this paper, a newly-developed vehicle-mounted GPR detection system is introduced. We used a horizontal high-pass filter and a modified layer localization method to extract the underground layers. Besides, according to lab experiments and simulation analysis, we proposed theoretical methods for detecting the degree of compaction and delamination at the interface, respectively. Moreover, a field test was carried out and the estimated results showed a satisfactory accuracy of the system and methods. PMID:27929409

  11. Multifunctional paper strip based on GO-veiled Ag nanoparticles with highly SERS sensitive and deliverable properties for high-performance molecular detection.

    PubMed

    Yang, Cheng; Xu, Yuanyuan; Wang, Minghong; Li, Tianming; Huo, Yanyan; Yang, Chuanxi; Man, Baoyuan

    2018-04-16

    The development of paper-based SERS substrates that can allow multi-component detection in real-word scenarios is of great value for applications in molecule detection under complex conditions. Here, a multifunctional SERS-based paper sensing substrate has been developed through the uniform patterning of high-density arrays of GO-isolated Ag nanoparticles on the hydrophilic porous cellulose paper strip (GO@AgNP@paper). Wet-chemical synthesis was used to provide the cover of SERS hot spots on any part of the paper, not just limited surface deposition. In virtue of the inherent ability of paper to deliver analytes by the capillary force, the detection ability of the GO@AgNP@paper substrate was greatly promoted, allowing as low as 10 -19 M R6G detection from microliter-volume (50 μL) samples. For the components with different polarity, the paper substrate can be used as an all-in-one machine to achieve the integration of separation and high-sensitive detection for ultralow mixture components, which improves the practical application value of SERS-based paper devices.

  12. Sensitive Detection of Capsaicinoids Using a Surface Plasmon Resonance Sensor with Anti-Homovanillic Acid Polyclonal Antibodies

    PubMed Central

    Nakamura, Shingo; Yatabe, Rui; Onodera, Takeshi; Toko, Kiyoshi

    2013-01-01

    Recently, highly functional biosensors have been developed in preparation for possible large-scale terrorist attacks using chemical warfare agents. Practically applicable sensors are required to have various abilities, such as high portability and operability, the capability of performing rapid and continuous measurement, as well as high sensitivity and selectivity. We developed the detection method of capsaicinoids, the main component of some lachrymators, using a surface plasmon resonance (SPR) immunosensor as an on-site detection sensor. Homovanillic acid, which has a vanillyl group similar to capsaicinoids such as capsaicin and dihydrocapsaicin, was bound to Concholepas concholepas hemocyanin (CCH) for use as an immunogen to generate polyclonal antibodies. An indirect competitive assay was carried out to detect capsaicinoids using SPR sensor chips on which different capsaicin analogues were immobilized. For the sensor chip on which 4-hydroxy-3-methoxybenzylamine hydrochloride was immobilized, a detection limit of 150 ppb was achieved. We found that the incubation time was not required and the detection can be completed in five minutes. PMID:25586413

  13. Rapid Detection Methods for Asphalt Pavement Thicknesses and Defects by a Vehicle-Mounted Ground Penetrating Radar (GPR) System.

    PubMed

    Dong, Zehua; Ye, Shengbo; Gao, Yunze; Fang, Guangyou; Zhang, Xiaojuan; Xue, Zhongjun; Zhang, Tao

    2016-12-06

    The thickness estimation of the top surface layer and surface layer, as well as the detection of road defects, are of great importance to the quality conditions of asphalt pavement. Although ground penetrating radar (GPR) methods have been widely used in non-destructive detection of pavements, the thickness estimation of the thin top surface layer is still a difficult problem due to the limitations of GPR resolution and the similar permittivity of asphalt sub-layers. Besides, the detection of some road defects, including inadequate compaction and delamination at interfaces, require further practical study. In this paper, a newly-developed vehicle-mounted GPR detection system is introduced. We used a horizontal high-pass filter and a modified layer localization method to extract the underground layers. Besides, according to lab experiments and simulation analysis, we proposed theoretical methods for detecting the degree of compaction and delamination at the interface, respectively. Moreover, a field test was carried out and the estimated results showed a satisfactory accuracy of the system and methods.

  14. Genetic testing for patients with renal disease: procedures, pitfalls, and ethical considerations.

    PubMed

    Korf, B R

    1999-07-01

    The Human Genome Project is rapidly producing insights into the molecular basis of human genetic disorders. The most immediate clinical benefit is the advent of new diagnostic methods. Molecular diagnostic tools are available for several genetic renal disorders and are in development for many more. Two general approaches to molecular diagnosis are linkage-based testing and direct mutation detection. The former is used when the gene has not been cloned but has been mapped in relation to polymorphic loci. Linkage-based testing is also helpful when a large diversity of mutations makes direct detection difficult. Limitations include the need to study multiple family members, the need for informative polymorphisms, and genetic heterogeneity. Direct mutation detection is limited by genetic heterogeneity and the need to distinguish nonpathogenic allelic variants from pathogenic mutations. Molecular testing raises a number of complex ethical issues, including those associated with prenatal or presymptomatic diagnosis. In addition, there are concerns about informed consent, privacy, genetic discrimination, and technology transfer for newly developed tests. Health professionals need to be aware of the technical and ethical implications of these new methods of testing, as well as the complexities in test interpretation, as molecular approaches are increasingly integrated into medical practice.

  15. Pen-on-paper strategy for point-of-care testing: Rapid prototyping of fully written microfluidic biosensor.

    PubMed

    Li, Zedong; Li, Fei; Xing, Yue; Liu, Zhi; You, Minli; Li, Yingchun; Wen, Ting; Qu, Zhiguo; Ling Li, Xiao; Xu, Feng

    2017-12-15

    Paper-based microfluidic biosensors have recently attracted increasing attentions in point-of-care testing (POCT) territories benefiting from their affordable, accessible and eco-friendly features, where technologies for fabricating such biosensors are preferred to be equipment free, easy-to-operate and capable of rapid prototyping. In this work, we developed a pen-on-paper (PoP) strategy based on two custom-made pens, i.e., a wax pen and a conductive-ink pen, to fully write paper-based microfluidic biosensors through directly writing both microfluidic channels and electrodes. Particularly, the proposed wax pen is competent to realize one-step fabrication of wax channels on paper, as the melted wax penetrates into paper during writing process without any post-treatments. The practical applications of the fabricated paper-based microfluidic biosensors are demonstrated by both colorimetric detection of Salmonella typhimurium DNA with detection limit of 1nM and electrochemical measurement of glucose with detection limit of 1mM. The developed PoP strategy for making microfluidic biosensors on paper characterized by true simplicity, prominent portability and excellent capability for rapid prototyping shows promising prospect in POCT applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Separation of oxalate, formate and glycolate in human body fluid samples by capillary electrophoresis with contactless conductometric detection.

    PubMed

    Kubáň, Petr; Ďurč, Pavol; Bittová, Miroslava; Foret, František

    2014-01-17

    A new method for rapid determination of toxic metabolites after methanol and ethylene glycol intoxication - oxalate, formate and glycolate in various body fluid samples (blood serum, saliva, urine, exhaled breath condensate) by capillary electrophoresis with contactless conductometric detection was developed. A selective separation of the three target analytes from other constituents present in the analyzed biological matrices was achieved in less than 6min in a fused silica capillary of 25μm I.D. using an electrolyte comprising 50mM l-histidine and 50mM 2-(N-morpholino)ethanesulfonic acid at pH 6.1. The only sample preparation was dilution with deionized water. The limits of detection were 0.4, 0.6 and 1.3μM and limits of quantitation 1.3, 1.9 and 4.2μM for oxalate, formate and glycolate, respectively. The method provides a simple and rapid diagnostic test in suspected intoxication and is able to distinguish the ingested liquid, based on its metabolite trace. The method presents a fast screening tool that can be applicable in clinical practice. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Astronomical aspects of cosmic threats: new problems and approaches to asteroid—comet hazard following the chelyabinsk event of February 15, 2013

    NASA Astrophysics Data System (ADS)

    Shustov, B. M.; Shugarov, A. S.; Naroenkov, S. A.; Prokhorov, M. E.

    2015-10-01

    A new definition of hazardous celestial bodies (HCBs) is introduced, in which the lower limit of the size of a HCB is reduced to 10 m. A new definition for threatening and collisional orbits of DCBs is introduced. The main astronomical factors that must be taken into account when creating systems for the detection of HCBs are analyzed. The most important of these are the uniformity of the distribution of points (regions) for the appearance of HCBs on the celestial sphere in near-Earth space and the practical limit for the velocity of approach of a HCB of 20 km/s (for 90% of bodies). It is shown that the creation of a system for the nearby detection of asteroids and comets arriving from the daytime sky requires the use of a space-based system. A concept for such a system, in which one or several optical telescopes are placed in the vicinity of the libration point L1 for the Sun—Earth system, is developed. Preliminary plans for such a system, called the System for the Detection of Daytime Asteroids (SDDA), are briefly described.

  18. Mycobacterium tuberculosis and whole genome sequencing: a practical guide and online tools available for the clinical microbiologist.

    PubMed

    Satta, G; Atzeni, A; McHugh, T D

    2017-02-01

    Whole genome sequencing (WGS) has the potential to revolutionize the diagnosis of Mycobacterium tuberculosis infection but the lack of bioinformatic expertise among clinical microbiologists is a barrier for adoption. Software products for analysis should be simple, free of charge, able to accept data directly from the sequencer (FASTQ files) and to provide the basic functionalities all-in-one. The main aim of this narrative review is to provide a practical guide for the clinical microbiologist, with little or no practical experience of WGS analysis, with a specific focus on software products tailor-made for M. tuberculosis analysis. With sequencing performed by an external provider, it is now feasible to implement WGS analysis in the routine clinical practice of any microbiology laboratory, with the potential to detect resistance weeks before traditional phenotypic culture methods, but the clinical microbiologist should be aware of the limitations of this approach. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Visual detection of glial cell line-derived neurotrophic factor based on a molecular translator and isothermal strand-displacement polymerization reaction

    PubMed Central

    Zhang, Li-Yong; Xing, Tao; Du, Li-Xin; Li, Qing-Min; Liu, Wei-Dong; Wang, Ji-Yue; Cai, Jing

    2015-01-01

    Background Glial cell line-derived neurotrophic factor (GDNF) is a small protein that potently promotes the survival of many types of neurons. Detection of GDNF is vital to monitoring the survival of sympathetic and sensory neurons. However, the specific method for GDNF detection is also un-discovered. The purpose of this study is to explore the method for protein detection of GDNF. Methods A novel visual detection method based on a molecular translator and isothermal strand-displacement polymerization reaction (ISDPR) has been proposed for the detection of GDNF. In this study, a molecular translator was employed to convert the input protein to output deoxyribonucleic acid signal, which was further amplified by ISDPR. The product of ISDPR was detected by a lateral flow biosensor within 30 minutes. Results This novel visual detection method based on a molecular translator and ISDPR has very high sensitivity and selectivity, with a dynamic response ranging from 1 pg/mL to 10 ng/mL, and the detection limit was 1 pg/mL of GDNF. Conclusion This novel visual detection method exhibits high sensitivity and selectivity, which is very simple and universal for GDNF detection to help disease therapy in clinical practice. PMID:25848224

  20. Missed, Misused, or Mismanaged: Improving Early Detection Systems to Optimize Child Outcomes

    ERIC Educational Resources Information Center

    Macy, Marisa; Marks, Kevin; Towle, Alexander

    2014-01-01

    Early detection efforts have been shown to vary greatly in practice, and there is a general lack of systematic accountability built into monitoring early detection effort impact. This article reviews current early detection practices and the drawbacks of these practices, with particular attention given to prevalent issues of mismeasurement,…

  1. 40 CFR 63.7500 - What emission limits, work practice standards, and operating limits must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Industrial, Commercial, and Institutional Boilers and Process Heaters Emission Limits and Work Practice... emission limit and work practice standard in Table 1 to this subpart that applies to your boiler or process... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What emission limits, work practice...

  2. Classical vs. evolved quenching parameters and procedures in scintillation measurements: The importance of ionization quenching

    NASA Astrophysics Data System (ADS)

    Bagán, H.; Tarancón, A.; Rauret, G.; García, J. F.

    2008-07-01

    The quenching parameters used to model detection efficiency variations in scintillation measurements have not evolved since the decade of 1970s. Meanwhile, computer capabilities have increased enormously and ionization quenching has appeared in practical measurements using plastic scintillation. This study compares the results obtained in activity quantification by plastic scintillation of 14C samples that contain colour and ionization quenchers, using classical (SIS, SCR-limited, SCR-non-limited, SIS(ext), SQP(E)) and evolved (MWA-SCR and WDW) parameters and following three calibration approaches: single step, which does not take into account the quenching mechanism; two steps, which takes into account the quenching phenomena; and multivariate calibration. Two-step calibration (ionization followed by colour) yielded the lowest relative errors, which means that each quenching phenomenon must be specifically modelled. In addition, the sample activity was quantified more accurately when the evolved parameters were used. Multivariate calibration-PLS also yielded better results than those obtained using classical parameters, which confirms that the quenching phenomena must be taken into account. The detection limits for each calibration method and each parameter were close to those obtained theoretically using the Currie approach.

  3. Novel analytical approach to a multi-sugar whole gut permeability assay.

    PubMed

    van Wijck, Kim; van Eijk, Hans M H; Buurman, Wim A; Dejong, Cornelis H C; Lenaerts, Kaatje

    2011-09-15

    Many pathophysiological conditions are associated with increased gastrointestinal permeability, reflecting an elevated risk of endotoxaemia, inflammation, and sepsis. Permeability tests are increasingly used in clinical practice to obtain information on gastrointestinal functioning, but tests are often restricted to the small intestine, and require large oral sugar doses. Therefore, a novel multi-sugar assay was developed, allowing assessment of whole gut permeability changes in urinary and plasma samples collected at regular intervals from 10 healthy volunteers at baseline and after intake of monosaccharides (rhamnose and erythritol) and disaccharides (sucrose, lactulose, and sucralose). Samples were analyzed by isocratic cation-exchange LC-MS. Sample preparation and detection conditions were optimized. After centrifugation, chromatographic separation was achieved on an IOA-1000 column set at 30°C. Column effluent was mixed with ammonia for sugar-ammonium adduct formation. The lower limit of detection was 0.05 μmol/L for disaccharides and 0.1 μmol/L for monosaccharides. Linearity for each probe was between 1 and 1000 μmol/L (R(2): 0.9987-0.9999). Coefficients of variation were <5% in urine, and <9% in plasma. Recovery data were within the 90% to 110% range at all spiked concentrations. This highly sensitive novel LC-MS approach resulted in a significant decrease of the detection limit for all sugar probes, allowing a 5-fold reduction of the commonly used lactulose dose and the addition of sugar probes to also assess the gastroduodenal and colon permeability. In combination with its extended application in plasma, these features make the novel assay a promising tool in the assessment of site-specific changes in gastrointestinal permeability in clinical practice. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Bacterial contamination of the hands of food handlers as indicator of hand washing efficacy in some convenient food industries in South Africa.

    PubMed

    Aa, Lambrechts; Is, Human; Jh, Doughari; Jfr, Lues

    2014-07-01

    Hands of ready-to-eat food service employees have been shown to be vectors in the spread of foodborne disease, mainly because of poor personal hygiene and accounting for approximately 97% of food borne illnesses in food service establishments and homes. Our objective was to evaluate the efficacy of hand washing practices and sanitation before commencing work among food handlers in the convenient food industry in Gauteng, South Africa. A total of 230 samples were collected, involving 100% of the food handlers, in 8 selected convenient food outlets with their main focus on preparing ready-to-eat foods. The workers' cleaned and disinfected dominant hands were sampled for Total Plate Count (TPC), Staphylococcus aureus and Escherichia coli. Bacteria were isolated and counted using standard methods. The highest bacterial count from the hand samples was 7.4 x 10(3) cfu.cm(-2) and the lowest showed no detectable growth. Although hands with a count of 0 cfu.cm(-2) were found in all of the plants, the results indicated that all the plants exceeded the legal limit for food surfaces or hands of < 100 cfu.cm(-2) when the average bacterial counts on hands were compared. Sixty percent of the TPC analysed exceeded the legal limit and only 18% of the food handlers had no bacteria detectable on their hands. One sample tested positive for E. coli and S. aureus could not be detected on the hands of any of the food handlers. The study revealed that hand hygiene is unsatisfactory and may have serious implications for public health due to contamination of food from food handlers' hands. This therefore underlined the importance of further training to improve food handlers' knowledge of good hand washing practices.

  5. Detecting Precontact Anthropogenic Microtopographic Features in a Forested Landscape with Lidar: A Case Study from the Upper Great Lakes Region, AD 1000-1600

    PubMed Central

    Howey, Meghan C. L.; Sullivan, Franklin B.; Tallant, Jason; Kopple, Robert Vande; Palace, Michael W.

    2016-01-01

    Forested settings present challenges for understanding the full extent of past human landscape modifications. Field-based archaeological reconnaissance in forests is low-efficiency and most remote sensing techniques are of limited utility, and together, this means many past sites and features in forests are unknown. Archaeologists have increasingly used light detection and ranging (lidar), a remote sensing tool that uses pulses of light to measure reflecting surfaces at high spatial resolution, to address these limitations. Archaeology studies using lidar have made significant progress identifying permanent structures built by large-scale complex agriculturalist societies. Largely unaccounted for, however, are numerous small and more practical modifications of landscapes by smaller-scale societies. Here we show these may also be detectable with lidar by identifying remnants of food storage pits (cache pits) created by mobile hunter-gatherers in the upper Great Lakes during Late Precontact (ca. AD 1000–1600) that now only exist as subtle microtopographic features. Years of intensive field survey identified 69 cache pit groups between two inland lakes in northern Michigan, almost all of which were located within ~500 m of a lakeshore. Applying a novel series of image processing techniques and statistical analyses to a high spatial resolution DTM we created from commercial-grade lidar, our detection routine identified 139 high potential cache pit clusters. These included most of the previously known clusters as well as several unknown clusters located >1500 m from either lakeshore, much further from lakeshores than all previously identified cultural sites. Food storage is understood to have emerged regionally as a risk-buffering strategy after AD 1000 but our results indicate the current record of hunter-gatherer cache pit food storage is markedly incomplete and this practice and its associated impact on the landscape may be greater than anticipated. Our study also demonstrates the potential of harnessing commercial-grade lidar for other fine-grained archaeology applications. PMID:27584031

  6. Detecting Precontact Anthropogenic Microtopographic Features in a Forested Landscape with Lidar: A Case Study from the Upper Great Lakes Region, AD 1000-1600.

    PubMed

    Howey, Meghan C L; Sullivan, Franklin B; Tallant, Jason; Kopple, Robert Vande; Palace, Michael W

    2016-01-01

    Forested settings present challenges for understanding the full extent of past human landscape modifications. Field-based archaeological reconnaissance in forests is low-efficiency and most remote sensing techniques are of limited utility, and together, this means many past sites and features in forests are unknown. Archaeologists have increasingly used light detection and ranging (lidar), a remote sensing tool that uses pulses of light to measure reflecting surfaces at high spatial resolution, to address these limitations. Archaeology studies using lidar have made significant progress identifying permanent structures built by large-scale complex agriculturalist societies. Largely unaccounted for, however, are numerous small and more practical modifications of landscapes by smaller-scale societies. Here we show these may also be detectable with lidar by identifying remnants of food storage pits (cache pits) created by mobile hunter-gatherers in the upper Great Lakes during Late Precontact (ca. AD 1000-1600) that now only exist as subtle microtopographic features. Years of intensive field survey identified 69 cache pit groups between two inland lakes in northern Michigan, almost all of which were located within ~500 m of a lakeshore. Applying a novel series of image processing techniques and statistical analyses to a high spatial resolution DTM we created from commercial-grade lidar, our detection routine identified 139 high potential cache pit clusters. These included most of the previously known clusters as well as several unknown clusters located >1500 m from either lakeshore, much further from lakeshores than all previously identified cultural sites. Food storage is understood to have emerged regionally as a risk-buffering strategy after AD 1000 but our results indicate the current record of hunter-gatherer cache pit food storage is markedly incomplete and this practice and its associated impact on the landscape may be greater than anticipated. Our study also demonstrates the potential of harnessing commercial-grade lidar for other fine-grained archaeology applications.

  7. Chronic disease detection and access: does access improve detection, or does detection make access more difficult?

    PubMed

    Anwar, Mohammed Saqib; Baker, Richard; Walker, Nicola; Mainous, Arch G; Bankart, M John

    2012-05-01

    The recorded detection of chronic disease by practices is generally lower than the prevalence predicted by population surveys. To determine whether patient-reported access to general practice predicts the recorded detection rates of chronic diseases in that setting. A cross-sectional study involving 146 general practices in Leicestershire and Rutland, England. The numbers of patients recorded as having chronic disease (coronary heart disease, chronic obstructive pulmonary disease, hypertension, diabetes) were obtained from Quality and Outcomes Framework (QOF) practice disease registers for 2008-2009. Characteristics of practice populations (deprivation, age, sex, ethnicity, proportion reporting poor health, practice turnover, list size) and practice performance (achievement of QOF disease indicators, patient experience of being able to consult a doctor within 2 working days and book an appointment >2 days in advance) were included in regression models. Patient characteristics (deprivation, age, poor health) and practice characteristics (list size, turnover, QOF achievement) were associated with recorded detection of more than one of the chronic diseases. Practices in which patients were more likely to report being able to book appointments had reduced recording rates of chronic disease. Being able to consult a doctor within 2 days was not associated with levels of recorded chronic disease. Practices with high levels of deprivation and older patients have increased rates of recorded chronic disease. As the number of patients recorded with chronic disease increased, the capacity of practices to meet patients' requests for appointments in advance declined. The capacity of some practices to detect and manage chronic disease may need improving.

  8. Culturally Competent Practice: A Mixed Methods Study Among Students, Academics and Alumni of Clinical Psychology Master’s Programs in the Netherlands

    PubMed Central

    Geerlings, Lennie R. C.; Thompson, Claire L.; Kraaij, Vivian; Keijsers, Ger P. J.

    2018-01-01

    This is the first research into preparation for multicultural clinical psychology practice in Europe. It applies the theory of multicultural counselling competency (MCC) to a case study in the Netherlands. It was hypothesized that cross-cultural practice experience, identification as a cultural minority, and satisfaction with cultural training was associated with MCC. The Multicultural Awareness Knowledge and Skills Survey was completed by 106 participants (22 students, 10 academics, 74 alumni) from clinical psychology masters’ programs. MANOVA detected a main effect of cross-cultural experience on MCC for all groups and universities. The data were enriched with exploratory qualitative data from 14 interviews (5 students, 5 academics, 4 alumni). Interpretative Phenomenological Analysis revealed three themes: limitations of clinical psychology, strategies for culturally competent practice, and strategies for cultural competency development. These outcomes suggest that cultural competency continues to require attention in master’s programs. The paper makes recommendations for further research enquiry related to training clinical psychologists to practice in Europe’s multicultural societies. PMID:29899800

  9. Are we pharmacovigilant enough in ophthalmic practice?

    PubMed Central

    Dubey, Ashok; Handu, Shailendra S

    2013-01-01

    No drug is absolutely safe. Pharmacovigilance is the science related to detection, assessment, understanding and prevention of adverse effects or any other possible drug-related problems. The ocular medications and devices can cause localized and systemic adverse effects. Not all adverse effects are known when a drug or device is launched in market because of limitations of clinical trials. Many adverse effects are recognized due to the spontaneous reporting of the vigilant doctors who observe and report such events encountered in their practice. Despite a large ophthalmic patient population base, India does not have robust adverse drug reaction (ADR) database because of lack of reporting culture. Government of India recently launched the Pharmacovigilance Programme of India (PvPI) to monitor ADRs and create awareness among the healthcare professionals about the importance of ADRs. Suspecting and reporting a possible drug reaction is very important in developing a safe and rational ophthalmic practice. PMID:23571233

  10. FORUM: Effective management of ecological resilience – are we there yet?

    USGS Publications Warehouse

    Spears, Bryan M.; Ives, Stephen C.; Angeler, David G.; Allen, Craig R.; Birk, Sebastian; Carvalho, Laurence; Cavers, Stephen; Daunt, Francis; Morton, R. Daniel; Pocock, Michael J. O.; Rhodes, Glenn; Thackeray, Stephen J.

    2015-01-01

    Ecological resilience is developing into a credible paradigm for policy development and environmental management for preserving natural capital in a rapidly changing world. However, resilience emerges from complex interactions, limiting the translation of theory into practice.Main limitations include the following: (i) difficulty in quantification and detection of changes in ecological resilience, (ii) a lack of empirical evidence to support preventative or proactive management and (iii) difficulties in managing processes operating across socio-ecological systems that vary in space and time.We highlight recent research with the potential to address these limitations including new and/or improved indicators of resilience and tools to assess scale as a driver of resilience.Synthesis and applications. Effective resilience-based management must be adaptive in nature. To support this, we propose an operational model using resilience-based iterative management actions operating across scales.

  11. Bacteriophages and dairy fermentations

    PubMed Central

    Marcó, Mariángeles Briggiler; Moineau, Sylvain; Quiberoni, Andrea

    2012-01-01

    This review highlights the main strategies available to control phage infection during large-scale milk fermentation by lactic acid bacteria. The topics that are emphasized include the factors influencing bacterial activities, the sources of phage contamination, the methods available to detect and quantify phages, as well as practical solutions to limit phage dispersion through an adapted factory design, the control of air flow, the use of adequate sanitizers, the restricted used of recycled products, and the selection and growth of bacterial cultures. PMID:23275866

  12. Electrochemical methods for monitoring of environmental carcinogens.

    PubMed

    Barek, J; Cvacka, J; Muck, A; Quaiserová, V; Zima, J

    2001-04-01

    The use of modern electroanalytical techniques, namely differential pulse polarography, differential pulse voltammetry on hanging mercury drop electrode or carbon paste electrode, adsorptive stripping voltammetry and high performance liquid chromatography with electrochemical detection for the determination of trace amounts of carcinogenic N-nitroso compounds, azo compounds, heterocyclic compounds, nitrated polycyclic aromatic hydrocarbons and aromatic and heterocyclic amines is discussed. Scope and limitations of these methods are described and some practical applications based on their combination with liquid-liquid or solid phase extraction are given.

  13. A critical appraisal of instruments to measure outcomes of interprofessional education.

    PubMed

    Oates, Matthew; Davidson, Megan

    2015-04-01

    Interprofessional education (IPE) is believed to prepare health professional graduates for successful collaborative practice. A range of instruments have been developed to measure the outcomes of IPE. An understanding of the psychometric properties of these instruments is important if they are to be used to measure the effectiveness of IPE. This review set out to identify instruments available to measure outcomes of IPE and collaborative practice in pre-qualification health professional students and to critically appraise the psychometric properties of validity, responsiveness and reliability against contemporary standards for instrument design. Instruments were selected from a pool of extant instruments and subjected to critical appraisal to determine whether they satisfied inclusion criteria. The qualitative and psychometric attributes of the included instruments were appraised using a checklist developed for this review. Nine instruments were critically appraised, including the widely adopted Readiness for Interprofessional Learning Scale (RIPLS) and the Interdisciplinary Education Perception Scale (IEPS). Validity evidence for instruments was predominantly based on test content and internal structure. Ceiling effects and lack of scale width contribute to the inability of some instruments to detect change in variables of interest. Limited reliability data were reported for two instruments. Scale development and scoring protocols were generally reported by instrument developers, but the inconsistent application of scoring protocols for some instruments was apparent. A number of instruments have been developed to measure outcomes of IPE in pre-qualification health professional students. Based on reported validity evidence and reliability data, the psychometric integrity of these instruments is limited. The theoretical test construction paradigm on which instruments have been developed may be contributing to the failure of some instruments to detect change in variables of interest following an IPE intervention. These limitations should be considered in any future research on instrument design. © 2015 John Wiley & Sons Ltd.

  14. Quality Factor Effect on the Wireless Range of Microstrip Patch Antenna Strain Sensors

    PubMed Central

    Daliri, Ali; Galehdar, Amir; Rowe, Wayne S. T.; John, Sabu; Wang, Chun H.; Ghorbani, Kamran

    2014-01-01

    Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA) design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection. PMID:24451457

  15. Quality factor effect on the wireless range of microstrip patch antenna strain sensors.

    PubMed

    Daliri, Ali; Galehdar, Amir; Rowe, Wayne S T; John, Sabu; Wang, Chun H; Ghorbani, Kamran

    2014-01-02

    Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA) design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection.

  16. QCM-nanomagnetic beads biosensor for lead ion detection.

    PubMed

    Zhang, Qingli; Cui, Haixia; Xiong, Xingliang; Chen, Jun; Wang, Ying; Shen, Jia; Luo, Yiting; Chen, Longcong

    2018-01-15

    As lead poses a serious threat to humans even in small amounts, all kinds of lead detection sensors with high sensitivity and selectivity are being constantly improved and put forward. In this report, a novel, simple and label-free quartz crystal microbalance (QCM) biosensor is proposed for detecting lead ions (Pb 2+ ). The biosensor takes full advantage of the high specificity of GR-5 DNAzyme to Pb 2+ and the high sensitivity of QCM. In particular, nanomagnetic beads (NMBs) are used as a novel and effective mean of signal amplification in the biosensor because of their mass and their ability to enhance the inductive effect, which are very beneficial for both higher sensitivity and a lower detection limit. In practice, GR-5 DNAzyme, innovatively combined with NMBs, was modified on the gold electrode of the QCM through gold-sulfur self-assembly. When the electrode was exposed to Pb 2+ solution, DNAzyme was severed into two parts at the RNA site (rA), along with the release of NMBs, which caused a great increase in frequency shift of the QCM electrode. Finally, a perfect linear correlation between the logarithm of Pb 2+ concentration and the change in frequency was obtained from 1 pM to 50 nM, with a detection limit as low as 0.3 pM. Moreover, the biosensor shows both an average recovery of 97 ± 6% in a drinking water sample and an excellent specificity for Pb 2+ compared with other metal ions.

  17. Cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles: a highly efficient SERS substrate for pesticide detection

    NASA Astrophysics Data System (ADS)

    Sun, Mei; Zhao, Aiwu; Wang, Dapeng; Wang, Jin; Chen, Ping; Sun, Henghui

    2018-04-01

    As a novel surface-enhanced Raman spectroscopic (SERS) nanocomposite, cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles (NPs) were synthesized for the first time. Cube-like α-Fe2O3 NPs with uniform size were achieved by optimizing reaction temperature and time. Firstly, the cube-like Fe3O4@SiO2 with good dispersity was achieved by calcining α-Fe2O3@SiO2 NPs in hydrogen atmosphere at 360 °C for 2.5 h, followed by self-assembling a PEI shell via sonication. Furthermore, the Au@Ag particles were densely assembled on the Fe3O4@SiO2 NPs to form the Fe3O4@SiO2@Au@Ag composite structure via strong Ag-N interaction. The obtained nanocomposites exhibited an excellent SERS behavior, reflected by the low detection of limit (p-ATP) at the 5 × 10-14 M level. Moreover, these nanocubes were used for the detection of thiram, and the detection limit can reach 5 × 10-11 M. Meanwhile, the U.S. Environmental Protection Agency specifies that the residue in fruit must be lower than 7 ppm. Hence, the resulting substrate with high SERS activity has great practical potential applications in the rapid detection of chemical, biological, and environment pollutants with a simple portable Raman instrument at trace level.

  18. Cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles: a highly efficient SERS substrate for detection of pesticide.

    PubMed

    Sun, Mei; Zhao, Aiwu; Wang, Dapeng; Wang, Jin; Chen, Ping; Sun, Henghui

    2018-02-09

    As a novel SERS nanocomposities, cube-like Fe3O4@SiO2@Au@Ag magnetic nanoparticles have been synthesized for the first time. Cube-like α-Fe2O3 NPs with uniform size can be achieved by optimizing reaction temperature and time. Firstly, the cube-like Fe3O4@SiO2 with good dispersity were achieved by calcining α-Fe2O3@SiO2 NPs in hydrogen atmosphere at 360 °C for 2.5 h, followed by self-assembling PEI shell via sonication. Furthermore, the Au@Ag particles can be densely assembled on the Fe3O4@SiO2 NPs to form the Fe3O4@SiO2@Au@Ag composite structure via strong Ag-N interaction. The obtained nanocomposites exhibit an excellent surface-enhanced Raman (SERS) behavior, reflected from low detection of limit (p-ATP) at 5×10-14 M level. Moreover, these nanocubes are used for detection of thiram and the detection limit can reach up to 5×10-11 M, while the rule of U.S. Environmental Protection Agency specifies that the residue in fruit must be lower than 7 ppm. Hence, the resulting substrate with high SERS activity has great practical potential applications in rapid detection of chemical, biological and environment pollutants with a simple portable Raman instrument at trace level. © 2018 IOP Publishing Ltd.

  19. A practical and highly sensitive C3N4-TYR fluorescent probe for convenient detection of dopamine

    NASA Astrophysics Data System (ADS)

    Li, Hao; Yang, Manman; Liu, Juan; Zhang, Yalin; Yang, Yanmei; Huang, Hui; Liu, Yang; Kang, Zhenhui

    2015-07-01

    The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules.The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03316k

  20. An SPR based sensor for allergens detection.

    PubMed

    Ashley, J; Piekarska, M; Segers, C; Trinh, L; Rodgers, T; Willey, R; Tothill, I E

    2017-02-15

    A simple, sensitive and label-free optical sensor method was developed for allergens analysis using α-casein as the biomarker for cow's milk detection, to be used directly in final rinse samples of cleaning in place systems (CIP) of food manufacturers. A Surface Plasmon Resonance (SPR) sensor chip consisting of four sensing arrays enabling the measurement of samples and control binding events simultaneously on the sensor surface was employed in this work. SPR offers several advantages in terms of label free detection, real time measurements and superior sensitivity when compared to ELISA based techniques. The gold sensor chip was used to immobilise α-casein-polyclonal antibody using EDC/NHS coupling procedure. The performance of the assay and the sensor was first optimised and characterised in pure buffer conditions giving a detection limit of 58ngmL -1 as a direct binding assay. The assay sensitivity can be further improved by using sandwich assay format and amplified with nanoparticles. However, at this stage this is not required as the detection limit achieved exceeded the required allergens detection levels of 2µgmL -1 for α-S1-casein. The sensor demonstrated good selectivity towards the α-casein as the target analyte and adequate recoveries from CIP final rinse wash samples. The sensor would be useful tool for monitoring allergen levels after cleaning procedures, providing additional data that may better inform upon wider food allergen risk management decision(s) that are made by food manufacturer. In particular, this sensor could potentially help validate or optimise cleaning practices for a given food manufacturing process. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The analysis of tetracyclines, quinolones, macrolides, lincosamides, pleuromutilins, and sulfonamides in chicken feathers using UHPLC-MS/MS in order to monitor antibiotic use in the poultry sector.

    PubMed

    Jansen, Larissa J M; Bolck, Yvette J C; Rademaker, Janneau; Zuidema, Tina; Berendsen, Bjorn J A

    2017-08-01

    In The Netherlands, all antibiotic treatments should be registered at the farm and in a central database. To enforce correct antibiotic use and registration, and to enforce prudent use of antibiotics, there is a need for methods that are able to detect antibiotic treatments. Ideally, such a method is able to detect antibiotic applications during the entire lifespan of an animal, including treatments administered during the first days of the animals' lives. Monitoring tissue, as is common practice, only provides a limited window of opportunity, as residue levels in tissue soon drop below measurable quantities. The analysis of feathers proves to be a promising tool in this respect. Furthermore, a qualitative confirmatory method was developed for the analyses of six major groups of antibiotics in ground chicken feathers, aiming for a detection limit as low as reasonably possible. The method was validated according to Commission Decision 2002/657/EC. All compounds comply with the criteria and, as a matter of fact, 58% of the compounds could also be quantified according to regulations. Additionally, we demonstrated that a less laborious method, in which whole feathers were analyzed, proved successful in the detection of applied antibiotics. Most compounds could be detected at levels of 2 μg kg -1 or below with the exception of sulfachloropyridazine, tylosin, and tylvalosin. This demonstrates the effectiveness of feather analysis to detect antibiotic use to allow effective enforcement of antibiotic use and prevent the illegal, off-label, and nonregistered use of antibiotics.

  2. 40 CFR 63.2378 - How do I demonstrate continuous compliance with the emission limitations, operating limits, and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance with the emission limitations, operating limits, and work practice standards? 63.2378 Section 63... limits, and work practice standards? (a) You must demonstrate continuous compliance with each emission limitation, operating limit, and work practice standard in Tables 2 through 4 to this subpart that applies to...

  3. Methods for Detecting Early Warnings of Critical Transitions in Time Series Illustrated Using Simulated Ecological Data

    PubMed Central

    Dakos, Vasilis; Carpenter, Stephen R.; Brock, William A.; Ellison, Aaron M.; Guttal, Vishwesha; Ives, Anthony R.; Kéfi, Sonia; Livina, Valerie; Seekell, David A.; van Nes, Egbert H.; Scheffer, Marten

    2012-01-01

    Many dynamical systems, including lakes, organisms, ocean circulation patterns, or financial markets, are now thought to have tipping points where critical transitions to a contrasting state can happen. Because critical transitions can occur unexpectedly and are difficult to manage, there is a need for methods that can be used to identify when a critical transition is approaching. Recent theory shows that we can identify the proximity of a system to a critical transition using a variety of so-called ‘early warning signals’, and successful empirical examples suggest a potential for practical applicability. However, while the range of proposed methods for predicting critical transitions is rapidly expanding, opinions on their practical use differ widely, and there is no comparative study that tests the limitations of the different methods to identify approaching critical transitions using time-series data. Here, we summarize a range of currently available early warning methods and apply them to two simulated time series that are typical of systems undergoing a critical transition. In addition to a methodological guide, our work offers a practical toolbox that may be used in a wide range of fields to help detect early warning signals of critical transitions in time series data. PMID:22815897

  4. An automated optofluidic biosensor platform combining interferometric sensors and injection moulded microfluidics.

    PubMed

    Szydzik, C; Gavela, A F; Herranz, S; Roccisano, J; Knoerzer, M; Thurgood, P; Khoshmanesh, K; Mitchell, A; Lechuga, L M

    2017-08-08

    A primary limitation preventing practical implementation of photonic biosensors within point-of-care platforms is their integration with fluidic automation subsystems. For most diagnostic applications, photonic biosensors require complex fluid handling protocols; this is especially prominent in the case of competitive immunoassays, commonly used for detection of low-concentration, low-molecular weight biomarkers. For this reason, complex automated microfluidic systems are needed to realise the full point-of-care potential of photonic biosensors. To fulfil this requirement, we propose an on-chip valve-based microfluidic automation module, capable of automating such complex fluid handling. This module is realised through application of a PDMS injection moulding fabrication technique, recently described in our previous work, which enables practical fabrication of normally closed pneumatically actuated elastomeric valves. In this work, these valves are configured to achieve multiplexed reagent addressing for an on-chip diaphragm pump, providing the sample and reagent processing capabilities required for automation of cyclic competitive immunoassays. Application of this technique simplifies fabrication and introduces the potential for mass production, bringing point-of-care integration of complex automated microfluidics into the realm of practicality. This module is integrated with a highly sensitive, label-free bimodal waveguide photonic biosensor, and is demonstrated in the context of a proof-of-concept biosensing assay, detecting the low-molecular weight antibiotic tetracycline.

  5. Rapid single cell detection of Staphylococcus aureus by aptamer-conjugated gold nanoparticles

    PubMed Central

    Chang, Yi-Chung; Yang, Chia-Ying; Sun, Ruei-Lin; Cheng, Yi-Feng; Kao, Wei-Chen; Yang, Pan-Chyr

    2013-01-01

    Staphylococcus aureus is one of the most important human pathogens, causing more than 500,000 infections in the United States each year. Traditional methods for bacterial culture and identification take several days, wasting precious time for patients who are suffering severe bacterial infections. Numerous nucleic acid-based detection methods have been introduced to address this deficiency; however, the costs and requirement for expensive equipment may limit the widespread use of such technologies. Thus, there is an unmet demand of new platform technology to improve the bacterial detection and identification in clinical practice. In this study, we developed a rapid, ultra-sensitive, low cost, and non-polymerase chain reaction (PCR)-based method for bacterial identification. Using this method, which measures the resonance light-scattering signal of aptamer-conjugated gold nanoparticles, we successfully detected single S. aureus cell within 1.5 hours. This new platform technology may have potential to develop a rapid and sensitive bacterial testing at point-of-care. PMID:23689505

  6. Rapid single cell detection of Staphylococcus aureus by aptamer-conjugated gold nanoparticles.

    PubMed

    Chang, Yi-Chung; Yang, Chia-Ying; Sun, Ruei-Lin; Cheng, Yi-Feng; Kao, Wei-Chen; Yang, Pan-Chyr

    2013-01-01

    Staphylococcus aureus is one of the most important human pathogens, causing more than 500,000 infections in the United States each year. Traditional methods for bacterial culture and identification take several days, wasting precious time for patients who are suffering severe bacterial infections. Numerous nucleic acid-based detection methods have been introduced to address this deficiency; however, the costs and requirement for expensive equipment may limit the widespread use of such technologies. Thus, there is an unmet demand of new platform technology to improve the bacterial detection and identification in clinical practice. In this study, we developed a rapid, ultra-sensitive, low cost, and non-polymerase chain reaction (PCR)-based method for bacterial identification. Using this method, which measures the resonance light-scattering signal of aptamer-conjugated gold nanoparticles, we successfully detected single S. aureus cell within 1.5 hours. This new platform technology may have potential to develop a rapid and sensitive bacterial testing at point-of-care.

  7. The application of microwave photonic detection in quantum communication

    NASA Astrophysics Data System (ADS)

    Diao, Wenting; Zhuang, Yongyong; Song, Xuerui; Wang, Liujun; Duan, Chongdi

    2018-03-01

    Quantum communication has attracted much attention in recent years, provides an ultimate level of security, and uniquely it is one of the most likely practical quantum technologies at present. In order to realize global coverage of quantum communication networks, not only need the help of satellite to realize wide area quantum communication, need implementation of optical fiber system to realize city to city quantum communication, but also, it is necessary to implement end-to-end quantum communications intercity and wireless quantum communications that can be received by handheld devices. Because of the limitation of application of light in buildings, it needs quantum communication with microwave band to achieve quantum reception of wireless handheld devices. The single microwave photon energy is very low, it is difficult to directly detect, which become a difficulty in microwave quantum detection. This paper summarizes the mode of single microwave photon detection methods and the possibility of application in microwave quantum communication, and promotes the development of quantum communication in microwave band and quantum radar.

  8. Enzyme-Encapsulated Liposome-Linked Immunosorbent Assay Enabling Sensitive Personal Glucose Meter Readout for Portable Detection of Disease Biomarkers.

    PubMed

    Lin, Bingqian; Liu, Dan; Yan, Jinmao; Qiao, Zhi; Zhong, Yunxin; Yan, Jiawei; Zhu, Zhi; Ji, Tianhai; Yang, Chaoyong James

    2016-03-23

    There is considerable demand for sensitive, selective, and portable detection of disease-associated proteins, particularly in clinical practice and diagnostic applications. Portable devices are highly desired for detection of disease biomarkers in daily life due to the advantages of being simple, rapid, user-friendly, and low-cost. Herein we report an enzyme-encapsulated liposome-linked immunosorbent assay for sensitive detection of proteins using personal glucose meters (PGM) for portable quantitative readout. Liposomes encapsulating a large amount of amyloglucosidase or invertase are surface-coated with recognition elements such as aptamers or antibodies for target recognition. By translating molecular recognition signal into a large amount of glucose with the encapsulated enzyme, disease biomarkers such as thrombin or C-reactive protein (CRP) can be quantitatively detected by a PGM with a high detection limit of 1.8 or 0.30 nM, respectively. With the advantages of portability, ease of use, and low-cost, the method reported here has potential for portable and quantitative detection of various targets for different POC testing scenarios, such as rapid diagnosis in clinic offices, health monitoring at the bedside, and chemical/biochemical safety control in the field.

  9. Fluorescent Metal-Organic Framework (MOF) as a Highly Sensitive and Quickly Responsive Chemical Sensor for the Detection of Antibiotics in Simulated Wastewater.

    PubMed

    Zhu, Xian-Dong; Zhang, Kun; Wang, Yu; Long, Wei-Wei; Sa, Rong-Jian; Liu, Tian-Fu; Lü, Jian

    2018-02-05

    A Zn(II)-based fluorescent metal-organic framework (MOF) was synthesized and applied as a highly sensitive and quickly responsive chemical sensor for antibiotic detection in simulated wastewater. The fluorescent chemical sensor, denoted FCS-1, exhibited enhanced fluorescence derived from its highly ordered, 3D MOF structure as well as excellent water stability in the practical pH range of simulated antibiotic wastewater (pH = 3.0-9.0). Remarkably, FCS-1 was able to effectively detect a series of sulfonamide antibiotics via photoinduced electron transfer that caused detectable fluorescence quenching, with fairly low detection limits. Two influences impacting measurements related to wastewater treatment and water quality monitoring, the presence of heavy-metal ions and the pH of solutions, were studied in terms of fluorescence quenching, which was nearly unaffected in sulfonamide-antibiotic detection. Additionally, the effective detection of sulfonamide antibiotics was rationalized by the theoretical computation of the energy bands of sulfonamide antibiotics, which revealed a good match between the energy bands of FCS-1 and sulfonamide antibiotics, in connection with fluorescence quenching in this system.

  10. Strategies for early melanoma detection: approaches to the patient with nevi

    PubMed Central

    Goodson, Agnessa G.; Grossman, Douglas

    2009-01-01

    Given its propensity to metastasize, and lack of effective therapies for most patients with advanced disease, early detection of melanoma is a clinical imperative. Although there are no non-invasive techniques for definitive diagnosis of melanoma, and the “gold standard” remains biopsy with histologic examination, a variety of modalities may facilitate early melanoma diagnosis and the detection of new and changing nevi. This article reviews general clinical principles of early melanoma detection, and various modalities that are currently available or on the horizon, providing the clinician with an up-to-date understanding of management strategies for their patients with numerous or atypical nevi. Learning objectives At the conclusion of this learning activity, participants should: 1) understand the clinical importance of early melanoma detection; 2) appreciate the challenges of early melanoma diagnosis and which patients are at highest risk; 3) know general principles of early melanoma detection; 4) be familiar with current and emerging modalities that may facilitate early melanoma diagnosis and the detection of new and changing nevi; 5) know the advantages and limitations of each modality; and 6) be able to practice a combined approach to the patient with numerous or clinically atypical nevi. PMID:19389517

  11. Tracing Acetylene Dissolved in Transformer Oil by Tunable Diode Laser Absorption Spectrum.

    PubMed

    Ma, Guo-Ming; Zhao, Shu-Jing; Jiang, Jun; Song, Hong-Tu; Li, Cheng-Rong; Luo, Ying-Ting; Wu, Hao

    2017-11-02

    Dissolved gas analysis (DGA) is widely used in monitoring and diagnosing of power transformer, since the insulation material in the power transformer decomposes gases under abnormal operation condition. Among the gases, acetylene, as a symbol of low energy spark discharge and high energy electrical faults (arc discharge) of power transformer, is an important monitoring parameter. The current gas detection method used by the online DGA equipment suffers from problems such as cross sensitivity, electromagnetic compatibility and reliability. In this paper, an optical gas detection system based on TDLAS technology is proposed to detect acetylene dissolved in transformer oil. We selected a 1530.370 nm laser in the near infrared wavelength range to correspond to the absorption peak of acetylene, while using the wavelength modulation strategy and Herriott cell to improve the detection precision. Results show that the limit of detection reaches 0.49 ppm. The detection system responds quickly to changes of gas concentration and is easily to maintenance while has no electromagnetic interference, cross-sensitivity, or carrier gas. In addition, a complete detection process of the system takes only 8 minutes, implying a practical prospect of online monitoring technology.

  12. The detection of T-Nos, a genetic element present in GMOs, by cross-priming isothermal amplification with real-time fluorescence.

    PubMed

    Zhang, Fang; Wang, Liu; Fan, Kai; Wu, Jian; Ying, Yibin

    2014-05-01

    An isothermal cross-priming amplification (CPA) assay for Agrobacterium tumefaciens nopaline synthase terminator (T-Nos) was established and investigated in this work. A set of six specific primers, recognizing eight distinct regions on the T-Nos sequence, was designed. The CPA assay was performed at a constant temperature, 63 °C, and detected by real-time fluorescence. The results indicated that real-time fluorescent CPA had high specificity, and the limit of detection was 1.06 × 10(3) copies of rice genomic DNA, which could be detected in 40 min. Comparison of real-time fluorescent CPA and conventional polymerase chain reaction (PCR) was also performed. Results revealed that real-time fluorescent CPA had a comparable sensitivity to conventional real-time PCR and had taken a shorter time. In addition, different contents of genetically modified (GM)-contaminated rice seed powder samples were detected for practical application. The result showed real-time fluorescent CPA could detect 0.5 % GM-contaminated samples at least, and the whole reaction could be finished in 35 min. Real-time fluorescent CPA is sensitive enough to monitor labeling systems and provides an attractive method for the detection of GMO.

  13. Electrochemical sensing of bisphenol using a multilayer graphene nanobelt modified photolithography patterned platinum electrode

    NASA Astrophysics Data System (ADS)

    Karthick Kannan, Padmanathan; Hu, Chunxiao; Morgan, Hywel; Moshkalev, Stanislav A.; Sekhar Rout, Chandra

    2016-09-01

    An electrochemical sensor has been developed for the detection of Bisphenol-A (BPA) using photolithographically patterned platinum electrodes modified with multilayer graphene nanobelts (GNB). Compared to bare electrodes, the GNB modified electrode exhibited enhanced BPA oxidation current, due to the high effective surface area and high adsorption capacity of the GNB. The sensor showed a linear response over the concentration range from 0.5 μM-9 μM with a very low limit of detection = 37.33 nM. In addition, the sensor showed very good stability and reproducibility with good specificity, demonstrating that GNB is potentially a new material for the development of a practical BPA electrochemical sensor with application in both industrial and plastic industries.

  14. Real-time multiplexed digital cavity-enhanced spectroscopy

    DOE PAGES

    Boyson, Toby K.; Dagdigian, Paul J.; Pavey, Karl D.; ...

    2015-10-01

    Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. In addition, this Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylatemore » and show parts-per-billion per root hertz sensitivity measured in real-time.« less

  15. Evolution of regulatory targets for drinking water quality.

    PubMed

    Sinclair, Martha; O'Toole, Joanne; Gibney, Katherine; Leder, Karin

    2015-06-01

    The last century has been marked by major advances in the understanding of microbial disease risks from water supplies and significant changes in expectations of drinking water safety. The focus of drinking water quality regulation has moved progressively from simple prevention of detectable waterborne outbreaks towards adoption of health-based targets that aim to reduce infection and disease to a level well below detection limits at the community level. This review outlines the changes in understanding of community disease and waterborne risks that prompted development of these targets, and also describes their underlying assumptions and current context. Issues regarding the appropriateness of selected target values, and how continuing changes in knowledge and practice may influence their evolution, are also discussed.

  16. Next-Generation Sequencing in Oncology: Genetic Diagnosis, Risk Prediction and Cancer Classification

    PubMed Central

    Kamps, Rick; Brandão, Rita D.; van den Bosch, Bianca J.; Paulussen, Aimee D. C.; Xanthoulea, Sofia; Blok, Marinus J.; Romano, Andrea

    2017-01-01

    Next-generation sequencing (NGS) technology has expanded in the last decades with significant improvements in the reliability, sequencing chemistry, pipeline analyses, data interpretation and costs. Such advances make the use of NGS feasible in clinical practice today. This review describes the recent technological developments in NGS applied to the field of oncology. A number of clinical applications are reviewed, i.e., mutation detection in inherited cancer syndromes based on DNA-sequencing, detection of spliceogenic variants based on RNA-sequencing, DNA-sequencing to identify risk modifiers and application for pre-implantation genetic diagnosis, cancer somatic mutation analysis, pharmacogenetics and liquid biopsy. Conclusive remarks, clinical limitations, implications and ethical considerations that relate to the different applications are provided. PMID:28146134

  17. Heteronuclear Correlation SSNMR Spectroscopy with Indirect Detection under Fast Magic-Angle Spinning [Book Chapter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayshi, Takeshi; Nishiyama, Yusuke; Pruski, Marek

    The main focus of this chapter is to address experimental strategies on the subject by providing a hands-on guide to fast MAS experiments, with a particular focus on indirect detection. Although our experience is limited to our respective laboratories in Ames and Yokohama, we hope that our descriptions of experimental setups and optimization procedures are sufficiently general to be applicable to all modern instruments. The chapter is organized as follows. Section 2 below introduces briefly the fast MAS technology and its main advantages. In Section 3, we describe the hardware associated with this remarkable technology and provide practical advices onmore » its use, including procedures for loading and unloading the samples, maintaining the probe, reducing t 1 noise, etc. In Section 4, we describe the principles and hands-on aspects of experiments involving the indirect detection of spin-1/2 and 14N nuclei« less

  18. Breath analysis using external cavity diode lasers: a review

    NASA Astrophysics Data System (ADS)

    Bayrakli, Ismail

    2017-04-01

    Most techniques that are used for diagnosis and therapy of diseases are invasive. Reliable noninvasive methods are always needed for the comfort of patients. Owing to its noninvasiveness, ease of use, and easy repeatability, exhaled breath analysis is a very good candidate for this purpose. Breath analysis can be performed using different techniques, such as gas chromatography mass spectrometry (MS), proton transfer reaction-MS, and selected ion flow tube-MS. However, these devices are bulky and require complicated procedures for sample collection and preconcentration. Therefore, these are not practical for routine applications in hospitals. Laser-based techniques with small size, robustness, low cost, low response time, accuracy, precision, high sensitivity, selectivity, low detection limit, real-time, and point-of-care detection have a great potential for routine use in hospitals. In this review paper, the recent advances in the fields of external cavity lasers and breath analysis for detection of diseases are presented.

  19. Limits to detection of generalized synchronization in delay-coupled chaotic oscillators.

    PubMed

    Kato, Hideyuki; Soriano, Miguel C; Pereda, Ernesto; Fischer, Ingo; Mirasso, Claudio R

    2013-12-01

    We study how reliably generalized synchronization can be detected and characterized from time-series analysis. To that end, we analyze synchronization in a generalized sense of delay-coupled chaotic oscillators in unidirectional ring configurations. The generalized synchronization condition can be verified via the auxiliary system approach; however, in practice, this might not always be possible. Therefore, in this study, widely used indicators to directly quantify generalized and phase synchronization from noise-free time series of two oscillators are employed complementarily to the auxiliary system approach. In our analysis, none of the indices provide the consistent results of the auxiliary system approach. Our findings indicate that it is a major challenge to directly detect synchronization in a generalized sense between two oscillators that are connected via a chain of other oscillators, even if the oscillators are identical. This has major consequences for the interpretation of the dynamics of coupled systems and applications thereof.

  20. Monitoring the Wobbe Index of Natural Gas Using Fiber-Enhanced Raman Spectroscopy.

    PubMed

    Sandfort, Vincenz; Trabold, Barbara M; Abdolvand, Amir; Bolwien, Carsten; Russell, Philip St. J; Wöllenstein, Jürgen; Palzer, Stefan

    2017-11-24

    The fast and reliable analysis of the natural gas composition requires the simultaneous quantification of numerous gaseous components. To this end, fiber-enhanced Raman spectroscopy is a powerful tool to detect most components in a single measurement using a single laser source. However, practical issues such as detection limit, gas exchange time and background Raman signals from the fiber material still pose obstacles to utilizing the scheme in real-world settings. This paper compares the performance of two types of hollow-core photonic crystal fiber (PCF), namely photonic bandgap PCF and kagomé-style PCF, and assesses their potential for online determination of the Wobbe index. In contrast to bandgap PCF, kagomé-PCF allows for reliable detection of Raman-scattered photons even below 1200 cm -1 , which in turn enables fast and comprehensive assessment of the natural gas quality of arbitrary mixtures.

  1. A new FRET ratiometric fluorescent chemosensor for Hg2+ and its application in living EC 109 cells

    NASA Astrophysics Data System (ADS)

    Song, Jianhua; Huai, Manxiu; Wang, Cuicui; Xu, Zhanhui; Zhao, Yufen; Ye, Yong

    2015-03-01

    On the basis of fluorescent resonance energy transfer, a new fluorophore dyad (L) bearing rhodamine B and naphthalimide was developed as fluorescent ratiometric chemosensor for Hg2+ in aqueous solution. L exhibited high selectivity and excellent sensitivity towards Hg2+ with a broad pH span (1.0-8.0) and the detection limit of L was 2.11 × 10-8 M. Sensor L for the detection of Hg2+ was rapid and the recognizing event could complete in 2.5 min. A significant change in the color could be used for naked-eye detection. The selective fluorescence response of L to Hg2+ is due to the Hg2+-promoted ring opening of spirolactam of rhodamine moiety, leading to a cyclization reaction of thiourea moiety. In addition, fluorescence imaging experiments of Hg2+ in living EC 109 cells demonstrated its value of practical applications in biological systems.

  2. Monitoring the Wobbe Index of Natural Gas Using Fiber-Enhanced Raman Spectroscopy

    PubMed Central

    Sandfort, Vincenz; Trabold, Barbara M.; Abdolvand, Amir; Bolwien, Carsten; Russell, Philip St. J.; Wöllenstein, Jürgen

    2017-01-01

    The fast and reliable analysis of the natural gas composition requires the simultaneous quantification of numerous gaseous components. To this end, fiber-enhanced Raman spectroscopy is a powerful tool to detect most components in a single measurement using a single laser source. However, practical issues such as detection limit, gas exchange time and background Raman signals from the fiber material still pose obstacles to utilizing the scheme in real-world settings. This paper compares the performance of two types of hollow-core photonic crystal fiber (PCF), namely photonic bandgap PCF and kagomé-style PCF, and assesses their potential for online determination of the Wobbe index. In contrast to bandgap PCF, kagomé-PCF allows for reliable detection of Raman-scattered photons even below 1200 cm−1, which in turn enables fast and comprehensive assessment of the natural gas quality of arbitrary mixtures. PMID:29186768

  3. Nickel-Cobalt Oxide Decorated Three-Dimensional Graphene as an Enzyme Mimic for Glucose and Calcium Detection.

    PubMed

    Wu, Meiyan; Meng, Shangjun; Wang, Qian; Si, Weili; Huang, Wei; Dong, Xiaochen

    2015-09-30

    Glucose and calcium ion play key roles in human bodies. The needlelike NiCo2O4 nanostructures are in situ deposited on three-dimensional graphene foam (3DGF) by a facile hydrothermal procedure. The structure and morphology of the hierarchical NiCo2O4/3DGF are characterized by scanning electron microscopy, transmission electron microscopy, and X-ray diffraction. With the self-standing NiCo2O4/3DGF as electrochemical electrode, it can realize the high-sensitivity detections for glucose and calcium ion. The limit of detection can reach 0.38 and 4.45 μM, respectively. In addition, the electrochemical electrode presents excellent selectivity for glucose and calcium ion. This study demonstrates that NiCo2O4/3DGF is a unique and promising material for practical application in both glucose and calcium ion sensing.

  4. High-Level Data Races

    NASA Technical Reports Server (NTRS)

    Artho, Cyrille; Havelund, Klaus; Biere, Armin; Koga, Dennis (Technical Monitor)

    2003-01-01

    Data races are a common problem in concurrent and multi-threaded programming. They are hard to detect without proper tool support. Despite the successful application of these tools, experience shows that the notion of data race is not powerful enough to capture certain types of inconsistencies occurring in practice. In this paper we investigate data races on a higher abstraction layer. This enables us to detect inconsistent uses of shared variables, even if no classical race condition occurs. For example, a data structure representing a coordinate pair may have to be treated atomically. By lifting the meaning of a data race to a higher level, such problems can now be covered. The paper defines the concepts view and view consistency to give a notation for this novel kind of property. It describes what kinds of errors can be detected with this new definition, and where its limitations are. It also gives a formal guideline for using data structures in a multi-threading environment.

  5. Design, properties and application of a facile fluorescence switch for Cu(II).

    PubMed

    Diao, Haipeng; Niu, Weiping; Liu, Wen; Feng, Liheng; Xie, Jun

    2017-01-05

    A facile fluorescence switch based on Schiff base 2,2'-[1,3-phenylenbis- (methylidynenitrilo)]bis[benzenethiol] (PMBB) has been developed and used to sensing metal ions. UV-vis absorption and fluorescence emission spectra show that the PMBB receptor has high selectivity and sensitivity for Cu(II) ions. Based on the photoinduced electron transfer (PET) and chelation enhanced fluorescence (CHEF) mechanisms, the receptor exhibits an fluorescence "turn-on" switch signal for Cu(II). The 1:1 binding mode of PMBB and Cu (II) ions can be obtained by the Job-plot and ESI-Mass spectra data. Noticeably, the color changes (from colorless to yellow) of PMBB solutions for Cu(II) sensing can be observed by naked eyes in the sunlight. The detection limit of the receptor for Cu(II) may reach 10(-7)mol/L with a good linear relation in the lower concentrations of Cu(II). To develop the practical application, the Cu(II) ions in swimming pool water samples were detected. Results show that PMBB receptor as a fluorescent probe can use to detect the trace level of Cu(II) in the environmental samples. This work contributes to providing a facile strategy for designing efficient probes and developing their practical application value. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A new electrochemical sensor for highly sensitive and selective detection of nitrite in food samples based on sonochemical synthesized Calcium Ferrite (CaFe2O4) clusters modified screen printed carbon electrode.

    PubMed

    Balasubramanian, Paramasivam; Settu, Ramki; Chen, Shen-Ming; Chen, Tse-Wei; Sharmila, Ganapathi

    2018-08-15

    Herein, we report a novel, disposable electrochemical sensor for the detection of nitrite ions in food samples based on the sonochemical synthesized orthorhombic CaFe 2 O 4 (CFO) clusters modified screen printed electrode. As synthesized CFO clusters were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transformer infrared spectroscopy (FT-IR), Thermogravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and amperometry (i-t). Under optimal condition, the CFO modified electrode displayed a rapid current response to nitrite, a linear response range from 0.016 to 1921 µM associated with a low detection limit 6.6 nM. The suggested sensor also showed the excellent sensitivity of 3.712 μA μM -1  cm -2 . Furthermore, a good reproducibility, long-term stability and excellent selectivity were also attained on the proposed sensor. In addition, the practical applicability of the sensor was investigated via meat samples, tap water and drinking water, and showed desirable recovery rate, representing its possibilities for practical application. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Technical specifications of low-frequency radio identification bedload tracking from field experiments: Differences in antennas, tags and operators

    NASA Astrophysics Data System (ADS)

    Arnaud, F.; Piégay, H.; Vaudor, L.; Bultingaire, L.; Fantino, G.

    2015-06-01

    Low-frequency passive integrated transponders (PIT tags) have been increasingly used for tracking bedload transport in gravel-bed rivers. Prior studies have reported high recovery rates in small streams, while recovery rates remained much lower in large systems, in large part because of the limited reading distance of the tags (< 1 m). Some laboratory tests have identified controlling factors for detection ranges (tag and antenna size, tag orientation, burial, submergence, etc.). Beyond these tests, improving our understanding of PIT tag functioning, using different equipment within different environments, is still needed in order to select the most suitable device for each geomorphic context. We address this knowledge gap with technical specifications for a low-frequency radio identification (RFID) device by working for the first time with real fluvial constraints, i.e., the gravel deposits and the aquatic channel. The three-dimensional detection envelopes of two types of tags and three types of antennas are quantified as well as the effect of practices (interoperator bias, battery power) on the detection. The interoperator variability and the intertag variability can be considered as negligible. The influence of burial in dry and water-saturated sediment and the influence of water immersion are shown to be minor. Finally, we summarize practical implications for RFID bedload tracking through these experiments.

  8. Rapid and sensitive detection of early esophageal squamous cell carcinoma with fluorescence probe targeting dipeptidylpeptidase IV

    PubMed Central

    Onoyama, Haruna; Kamiya, Mako; Kuriki, Yugo; Komatsu, Toru; Abe, Hiroyuki; Tsuji, Yosuke; Yagi, Koichi; Yamagata, Yukinori; Aikou, Susumu; Nishida, Masato; Mori, Kazuhiko; Yamashita, Hiroharu; Fujishiro, Mitsuhiro; Nomura, Sachiyo; Shimizu, Nobuyuki; Fukayama, Masashi; Koike, Kazuhiko; Urano, Yasuteru; Seto, Yasuyuki

    2016-01-01

    Early detection of esophageal squamous cell carcinoma (ESCC) is an important prognosticator, but is difficult to achieve by conventional endoscopy. Conventional lugol chromoendoscopy and equipment-based image-enhanced endoscopy, such as narrow-band imaging (NBI), have various practical limitations. Since fluorescence-based visualization is considered a promising approach, we aimed to develop an activatable fluorescence probe to visualize ESCCs. First, based on the fact that various aminopeptidase activities are elevated in cancer, we screened freshly resected specimens from patients with a series of aminopeptidase-activatable fluorescence probes. The results indicated that dipeptidylpeptidase IV (DPP-IV) is specifically activated in ESCCs, and would be a suitable molecular target for detection of esophageal cancer. Therefore, we designed, synthesized and characterized a series of DPP-IV-activatable fluorescence probes. When the selected probe was topically sprayed onto endoscopic submucosal dissection (ESD) or surgical specimens, tumors were visualized within 5 min, and when the probe was sprayed on biopsy samples, the sensitivity, specificity and accuracy reached 96.9%, 85.7% and 90.5%. We believe that DPP-IV-targeted activatable fluorescence probes are practically translatable as convenient tools for clinical application to enable rapid and accurate diagnosis of early esophageal cancer during endoscopic or surgical procedures. PMID:27245876

  9. Simple, Rapid, Sensitive, and Versatile SWNT-Paper Sensor for Environmental Toxin Detection Competitive with ELISA

    PubMed Central

    Wang, Libing; Chen, Wei; Xu, Dinghua; Shim, Bong Sup; Zhu, Yingyue; Sun, Fengxia; Liu, Liqiang; Peng, Chifang; Jin, Zhengyu; Xu, Chuanlai; Kotov, Nicholas A.

    2009-01-01

    Safety of water was for a long time and still is one of the most pressing needs for many countries and different communities. Despite the fact that there are potentially many methods to evaluate water safety, finding a simple, rapid, versatile, and inexpensive method for detection of toxins in everyday items is still a great challenge. In this study, we extend the concept of composites obtained impregnation of porous fibrous materials, such as fabrics and papers, by single walled carbon-nanotubes (SWNTs) toward very simple but high-performance biosensors. They utilize the strong dependence of electrical conductivity through nanotubes percolation network on the width of nanotubes-nanotube tunneling gap and can potentially satisfy all the requirements outlined above for the routine toxin monitoring. An antibody to the microcystin-LR (MC-LR), one of the common culprits in mass poisonings, was dispersed together with SWNTs. This dispersion was used to dip-coat the paper rendering it conductive. The change in conductivity of the paper was used to sense the MC-LR in the water rapidly and accurately. The method has the linear detection range up to 10 nmol/L and non-linear detection up to 40 nmol/L. The limit of detection was found to be 0.6 nmol/L (0.6 ng/mL), which satisfies the strictest World Health Organization standard for MC-LR content in drinking water (1 ng/mL), and is comparable to the detection limit of traditional ELISA method of MC-LR detection, while drastically reducing the time of analysis by more than an order of magnitude, which is one of the major hurdles in practical applications. Similar technology of sensor preparation can also be used for a variety of other rapid environmental sensors. PMID:19928776

  10. Investigation of the Sensitivity of Transmission Raman Spectroscopy for Polymorph Detection in Pharmaceutical Tablets.

    PubMed

    Feng, Hanzhou; Bondi, Robert W; Anderson, Carl A; Drennen, James K; Igne, Benoît

    2017-08-01

    Polymorph detection is critical for ensuring pharmaceutical product quality in drug substances exhibiting polymorphism. Conventional analytical techniques such as X-ray powder diffraction and solid-state nuclear magnetic resonance are utilized primarily for characterizing the presence and identity of specific polymorphs in a sample. These techniques have encountered challenges in analyzing the constitution of polymorphs in the presence of other components commonly found in pharmaceutical dosage forms. Laborious sample preparation procedures are usually required to achieve satisfactory data interpretability. There is a need for alternative techniques capable of probing pharmaceutical dosage forms rapidly and nondestructively, which is dictated by the practical requirements of applications such as quality monitoring on production lines or when quantifying product shelf lifetime. The sensitivity of transmission Raman spectroscopy for detecting polymorphs in final tablet cores was investigated in this work. Carbamazepine was chosen as a model drug, polymorph form III is the commercial form, whereas form I is an undesired polymorph that requires effective detection. The concentration of form I in a direct compression tablet formulation containing 20% w/w of carbamazepine, 74.00% w/w of fillers (mannitol and microcrystalline cellulose), and 6% w/w of croscarmellose sodium, silicon dioxide, and magnesium stearate was estimated using transmission Raman spectroscopy. Quantitative models were generated and optimized using multivariate regression and data preprocessing. Prediction uncertainty was estimated for each validation sample by accounting for all the main variables contributing to the prediction. Multivariate detection limits were calculated based on statistical hypothesis testing. The transmission Raman spectroscopic model had an absolute prediction error of 0.241% w/w for the independent validation set. The method detection limit was estimated at 1.31% w/w. The results demonstrated that transmission Raman spectroscopy is a sensitive tool for polymorphs detection in pharmaceutical tablets.

  11. A novel method for detection of phosphorylation in single cells by surface enhanced Raman scattering (SERS) using composite organic-inorganic nanoparticles (COINs).

    PubMed

    Shachaf, Catherine M; Elchuri, Sailaja V; Koh, Ai Leen; Zhu, Jing; Nguyen, Lienchi N; Mitchell, Dennis J; Zhang, Jingwu; Swartz, Kenneth B; Sun, Lei; Chan, Selena; Sinclair, Robert; Nolan, Garry P

    2009-01-01

    Detection of single cell epitopes has been a mainstay of immunophenotyping for over three decades, primarily using fluorescence techniques for quantitation. Fluorescence has broad overlapping spectra, limiting multiplexing abilities. To expand upon current detection systems, we developed a novel method for multi-color immuno-detection in single cells using "Composite Organic-Inorganic Nanoparticles" (COINs) Raman nanoparticles. COINs are Surface-Enhanced Raman Scattering (SERS) nanoparticles, with unique Raman spectra. To measure Raman spectra in single cells, we constructed an automated, compact, low noise and sensitive Raman microscopy device (Integrated Raman BioAnalyzer). Using this technology, we detected proteins expressed on the surface in single cells that distinguish T-cells among human blood cells. Finally, we measured intracellular phosphorylation of Stat1 (Y701) and Stat6 (Y641), with results comparable to flow cytometry. Thus, we have demonstrated the practicality of applying COIN nanoparticles for measuring intracellular phosphorylation, offering new possibilities to expand on the current fluorescent technology used for immunoassays in single cells.

  12. A Novel Method for Detection of Phosphorylation in Single Cells by Surface Enhanced Raman Scattering (SERS) using Composite Organic-Inorganic Nanoparticles (COINs)

    PubMed Central

    Shachaf, Catherine M.; Elchuri, Sailaja V.; Koh, Ai Leen; Zhu, Jing; Nguyen, Lienchi N.; Mitchell, Dennis J.; Zhang, Jingwu; Swartz, Kenneth B.; Sun, Lei; Chan, Selena; Sinclair, Robert; Nolan, Garry P.

    2009-01-01

    Background Detection of single cell epitopes has been a mainstay of immunophenotyping for over three decades, primarily using fluorescence techniques for quantitation. Fluorescence has broad overlapping spectra, limiting multiplexing abilities. Methodology/Principal Findings To expand upon current detection systems, we developed a novel method for multi-color immuno-detection in single cells using “Composite Organic-Inorganic Nanoparticles” (COINs) Raman nanoparticles. COINs are Surface-Enhanced Raman Scattering (SERS) nanoparticles, with unique Raman spectra. To measure Raman spectra in single cells, we constructed an automated, compact, low noise and sensitive Raman microscopy device (Integrated Raman BioAnalyzer). Using this technology, we detected proteins expressed on the surface in single cells that distinguish T-cells among human blood cells. Finally, we measured intracellular phosphorylation of Stat1 (Y701) and Stat6 (Y641), with results comparable to flow cytometry. Conclusions/Significance Thus, we have demonstrated the practicality of applying COIN nanoparticles for measuring intracellular phosphorylation, offering new possibilities to expand on the current fluorescent technology used for immunoassays in single cells. PMID:19367337

  13. Varying face occlusion detection and iterative recovery for face recognition

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Hu, Zhengping; Sun, Zhe; Zhao, Shuhuan; Sun, Mei

    2017-05-01

    In most sparse representation methods for face recognition (FR), occlusion problems were usually solved via removing the occlusion part of both query samples and training samples to perform the recognition process. This practice ignores the global feature of facial image and may lead to unsatisfactory results due to the limitation of local features. Considering the aforementioned drawback, we propose a method called varying occlusion detection and iterative recovery for FR. The main contributions of our method are as follows: (1) to detect an accurate occlusion area of facial images, an image processing and intersection-based clustering combination method is used for occlusion FR; (2) according to an accurate occlusion map, the new integrated facial images are recovered iteratively and put into a recognition process; and (3) the effectiveness on recognition accuracy of our method is verified by comparing it with three typical occlusion map detection methods. Experiments show that the proposed method has a highly accurate detection and recovery performance and that it outperforms several similar state-of-the-art methods against partial contiguous occlusion.

  14. Multi-Frequency Signal Detection Based on Frequency Exchange and Re-Scaling Stochastic Resonance and Its Application to Weak Fault Diagnosis.

    PubMed

    Liu, Jinjun; Leng, Yonggang; Lai, Zhihui; Fan, Shengbo

    2018-04-25

    Mechanical fault diagnosis usually requires not only identification of the fault characteristic frequency, but also detection of its second and/or higher harmonics. However, it is difficult to detect a multi-frequency fault signal through the existing Stochastic Resonance (SR) methods, because the characteristic frequency of the fault signal as well as its second and higher harmonics frequencies tend to be large parameters. To solve the problem, this paper proposes a multi-frequency signal detection method based on Frequency Exchange and Re-scaling Stochastic Resonance (FERSR). In the method, frequency exchange is implemented using filtering technique and Single SideBand (SSB) modulation. This new method can overcome the limitation of "sampling ratio" which is the ratio of the sampling frequency to the frequency of target signal. It also ensures that the multi-frequency target signals can be processed to meet the small-parameter conditions. Simulation results demonstrate that the method shows good performance for detecting a multi-frequency signal with low sampling ratio. Two practical cases are employed to further validate the effectiveness and applicability of this method.

  15. A highly stable electrochemiluminescence sensing system of cadmium sulfide nanowires/graphene hybrid for supersensitive detection of pentachlorophenol

    NASA Astrophysics Data System (ADS)

    Deng, Yanan; Chang, Quanying; Yin, Kai; Liu, Chengbin; Wang, Ying

    2017-10-01

    A highly stable and effective electrochemiluminescence (ECL) sensing system of cadmium sulfide nanowires/reduced graphene oxide (CdS NWS/rGO) hybrid is presented for supersensitive detection of pentachlorophenol (PCP). CdS nanowire is for the first time exploited in ECL sensing. The rGO served as both ECL signal amplifier and immobilization platform, can perfectly enhance the ECL intensity and stability of the sensing system. With S2O82- as coreactant, the ECL signal can be significantly quenched by the addition of PCP. The established ECL sensing system presents a wider linear range from 1.0 × 10-14 to 1.0 × 10-8 M and a much low detection limit of 2 × 10-15 M under the optimum test conditions (e.g., pH 7.0 and 100 mM S2O82-). Furthermore, the ECL sensing system displays a good selectivity for PCP detection. The practicability of the ECL sensing system in real water sample shows that this system could be promisingly applied in the analytical detection of PCP in real water environments.

  16. Automated intelligent video surveillance system for ships

    NASA Astrophysics Data System (ADS)

    Wei, Hai; Nguyen, Hieu; Ramu, Prakash; Raju, Chaitanya; Liu, Xiaoqing; Yadegar, Jacob

    2009-05-01

    To protect naval and commercial ships from attack by terrorists and pirates, it is important to have automatic surveillance systems able to detect, identify, track and alert the crew on small watercrafts that might pursue malicious intentions, while ruling out non-threat entities. Radar systems have limitations on the minimum detectable range and lack high-level classification power. In this paper, we present an innovative Automated Intelligent Video Surveillance System for Ships (AIVS3) as a vision-based solution for ship security. Capitalizing on advanced computer vision algorithms and practical machine learning methodologies, the developed AIVS3 is not only capable of efficiently and robustly detecting, classifying, and tracking various maritime targets, but also able to fuse heterogeneous target information to interpret scene activities, associate targets with levels of threat, and issue the corresponding alerts/recommendations to the man-in- the-loop (MITL). AIVS3 has been tested in various maritime scenarios and shown accurate and effective threat detection performance. By reducing the reliance on human eyes to monitor cluttered scenes, AIVS3 will save the manpower while increasing the accuracy in detection and identification of asymmetric attacks for ship protection.

  17. Rolling chain amplification based signal-enhanced electrochemical aptasensor for ultrasensitive detection of ochratoxin A.

    PubMed

    Huang, Lin; Wu, Jingjing; Zheng, Lei; Qian, Haisheng; Xue, Feng; Wu, Yucheng; Pan, Daodong; Adeloju, Samuel B; Chen, Wei

    2013-11-19

    A novel electrochemical aptasensor is described for rapid and ultrasensitive detection of ochratoxin A (OTA) based on signal enhancement with rolling circle amplification (RCA). The primer for RCA was designed to compose of a two-part sequence, one part of the aptamer sequence directed against OTA while the other part was complementary to the capture probe on the electrode surface. In the presence of target OTA, the primer, originally hybridized with the RCA padlock, is replaced to combine with OTA. This induces the inhibition of RCA and decreases the OTA sensing signal obtained with the electrochemical aptasensor. Under the optimized conditions, ultrasensitive detection of OTA was achieved with a limit of detection (LOD) of 0.065 ppt (pg/mL), which is much lower than previously reported. The electrochemical aptasensor was also successfully applied to the determination of OTA in wine samples. This ultrasensitive electrochemical aptasensor is of great practical importance in food safety and could be widely extended to the detection of other toxins by replacing the sequence of the recognition aptamer.

  18. Nucleic acid in-situ hybridization detection of infectious agents

    NASA Astrophysics Data System (ADS)

    Thompson, Curtis T.

    2000-04-01

    Limitations of traditional culture methods and newer polymerase chain reaction (PCR)-based methods for detection and speciation of infectious agents demonstrate the need for more rapid and better diagnostics. Nucleic acid hybridization is a detection technology that has gained wide acceptance in cancer and prenatal cytogenetics. Using a modification of the nucleic acid hybridization technique known as fluorescence in-situ hybridization, infectious agents can be detected in a variety of specimens with high sensitivity and specificity. The specimens derive from all types of human and animal sources including body fluids, tissue aspirates and biopsy material. Nucleic acid hybridization can be performed in less than one hour. The result can be interpreted either using traditional fluorescence microscopy or automated platforms such as micro arrays. This paper demonstrates proof of concept for nucleic acid hybridization detection of different infectious agents. Interpretation within a cytologic and histologic context is possible with fluorescence microscopic analysis, thereby providing confirmatory evidence of hybridization. With careful probe selection, nucleic acid hybridization promises to be a highly sensitive and specific practical diagnostic alternative to culture, traditional staining methods, immunohistochemistry and complicated nucleic acid amplification tests.

  19. Detecting Thermal Cloaks via Transient Effects

    PubMed Central

    Sklan, Sophia R.; Bai, Xue; Li, Baowen; Zhang, Xiang

    2016-01-01

    Recent research on the development of a thermal cloak has concentrated on engineering an inhomogeneous thermal conductivity and an approximate, homogeneous volumetric heat capacity. While the perfect cloak of inhomogeneous κ and inhomogeneous ρcp is known to be exact (no signals scattering and only mean values penetrating to the cloak’s interior), the sensitivity of diffusive cloaks to defects and approximations has not been analyzed. We analytically demonstrate that these approximate cloaks are detectable. Although they work as perfect cloaks in the steady-state, their transient (time-dependent) response is imperfect and a small amount of heat is scattered. This is sufficient to determine the presence of a cloak and any heat source it contains, but the material composition hidden within the cloak is not detectable in practice. To demonstrate the feasibility of this technique, we constructed a cloak with similar approximation and directly detected its presence using these transient temperature deviations outside the cloak. Due to limitations in the range of experimentally accessible volumetric specific heats, our detection scheme should allow us to find any realizable cloak, assuming a sufficiently large temperature difference. PMID:27605153

  20. Role of contrast-enhanced ultrasonography with Sonazoid for hepatocellular carcinoma: evidence from a 10-year experience.

    PubMed

    Maruyama, Hitoshi; Sekimoto, Tadashi; Yokosuka, Osamu

    2016-05-01

    Hepatocellular carcinoma (HCC) represents primary liver cancer. Because the development of HCC limits the prognosis as well as the quality of life of the patients, its management should be properly conducted based on an accurate diagnosis. The liver is the major target organ of ultrasound (US), which is the simple, non-invasive, and real-time imaging method available worldwide. Microbubble-based contrast agents are safe and reliable and have become popular, which has resulted in the improvement of diagnostic performances of US due to the increased detectability of the peripheral blood flow. Sonazoid (GE Healthcare, Waukesha, WI, USA), a second-generation contrast agent, shows the unique property of accumulation in the liver and spleen. Contrast-enhanced US with Sonazoid is now one of the most frequently used modalities in the practical management of liver tumors, including the detection and characterization of the nodule, evaluation of the effects of non-surgical treatment, intraoperative support, and post-treatment surveillance. This article reviews the 10-year evidence for contrast-enhanced US with Sonazoid in the practical management of HCC.

  1. Tamper-indicating seals : practices, problems, and standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, R. G.

    2003-01-01

    Tamper-indicating seals have been used by customs officials for over 7,000 years. Today, seals are widely used to help counter theft, smuggling, sabotage, vandalism, terrorism, and espionage. Despite their antiquity and modern widespread use, however, there remains considerable confusion about seals, as well as a lot of misconceptions, wishful thinking, sloppy terminology, and poor practice. The absence of meaningful norms and standards, together with the surprisingly limited amount of research and development (R&D) in the field of tamper detection, has also hindered the effective use of seals. The Vulnerability Assessment Team (VAT) at Los Alamos National Laboratory has intensively studiedmore » tamper-indicating seals for the last 12 years. We have engaged in vulnerability assessments, R&D, consulting, and training for over two dozen United States government agencies and private companies, as well as for the International Atomic Energy Agency (IAEA) and Euratom. The VAT has also analyzed over 200 different types of seals in detail. This paper summarizes some of our conclusions, recommendations, and warnings regarding seals and tamper detection.« less

  2. Predicting the onset of psychosis in patients at clinical high risk: practical guide to probabilistic prognostic reasoning.

    PubMed

    Fusar-Poli, P; Schultze-Lutter, F

    2016-02-01

    Prediction of psychosis in patients at clinical high risk (CHR) has become a mainstream focus of clinical and research interest worldwide. When using CHR instruments for clinical purposes, the predicted outcome is but only a probability; and, consequently, any therapeutic action following the assessment is based on probabilistic prognostic reasoning. Yet, probabilistic reasoning makes considerable demands on the clinicians. We provide here a scholarly practical guide summarising the key concepts to support clinicians with probabilistic prognostic reasoning in the CHR state. We review risk or cumulative incidence of psychosis in, person-time rate of psychosis, Kaplan-Meier estimates of psychosis risk, measures of prognostic accuracy, sensitivity and specificity in receiver operator characteristic curves, positive and negative predictive values, Bayes' theorem, likelihood ratios, potentials and limits of real-life applications of prognostic probabilistic reasoning in the CHR state. Understanding basic measures used for prognostic probabilistic reasoning is a prerequisite for successfully implementing the early detection and prevention of psychosis in clinical practice. Future refinement of these measures for CHR patients may actually influence risk management, especially as regards initiating or withholding treatment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  4. Using SPOT-5 images in rice farming for detecting BPH (Brown Plant Hopper)

    NASA Astrophysics Data System (ADS)

    Ghobadifar, F.; Wayayok, A.; Shattri, M.; Shafri, H.

    2014-06-01

    Infestation of rice plant-hopper such as Brown Plant Hopper (BPH) (Nilaparvata lugens) is one of the most notable risk in rice yield in tropical areas especially in Asia. In order to use visible and infrared images to detect stress in rice production caused by BPH infestation, several remote sensing techniques have been developed. Initial recognition of pest infestation by means of remote sensing will spreads, for precision farming practice. To address this issue, detection of sheath blight in rice farming was examined by using SPOT-5 images. Specific image indices such as Normalized decrease food production costs, limit environmental hazards, and enhance natural pest control before the problem Normalized Difference Vegetation Index (NDVI), Standard difference indices (SDI) and Ratio Vegetation Index (RVI) were used for analyses using ENVI 4.8 and SPSS software. Results showed that all the indices to recognize infected plants are significant at α = 0.01. Examination of the association between the disease indices indicated that band 3 (near infrared) and band 4 (mid infrared) have a relatively high correlation. The selected indices declared better association for detecting healthy plants from diseased ones. Consequently, these sorts of indices especially NDVI could be valued as indicators for developing techniques for detecting the sheath blight of rice by using remote sensing. This infers that they are useful for crop disease detection but the spectral resolution is probably not sufficient to distinguish plants with light infections (low severity level). Using the index as an indicator can clarify the threshold for zoning the outbreaks. Quick assessment information is very useful in precision farming to practice site specific management such as pesticide application.

  5. A molecular rotor based ratiometric sensor for basic amino acids

    NASA Astrophysics Data System (ADS)

    Pettiwala, Aafrin M.; Singh, Prabhat K.

    2018-01-01

    The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples.

  6. Amplified fluorescent aptasensor through catalytic recycling for highly sensitive detection of ochratoxin A.

    PubMed

    Wei, Yin; Zhang, Ji; Wang, Xu; Duan, Yixiang

    2015-03-15

    This paper describes a novel approach utilizing nano-graphite-aptamer hybrid and DNase I for the amplified detection of ochratoxin A (OTA) for the first time. Nano-graphite can effectively quench the fluorescence of carboxyfluorescein (FAM) labeled OTA specific aptamer due to their strong π-π; stacking interactions; while upon OTA addition, it will bind with aptamer to fold into an OTA-aptamerG-quadruplex structure, which does not adsorb on the surface of nano-graphite and thus retains the dye fluorescence. Meanwhile, the G-quadruplex structure can be cleaved by DNase I, and in such case OTA is delivered from the complex. The released OTA then binds other FAM-labeled aptamers on the nano-graphite surface, and touches off another target recycling, resulting in the successive release of dye-labeled aptamers from the nano-graphite, which leads to significant amplification of the signal. Under the optimized conditions, the present amplified sensing system exhibits high sensitivity toward OTA with a limit of detection of 20nM (practical measurement), which is about 100-fold higher than that of traditional unamplified homogeneous assay. Our developed method also showed high selectivity against other interference molecules and can be applied for the detection of OTA in real red wine samples. The proposed assay is simple, cost-effective, and might open a door for the development of new assays for other biomolecules. This aptasensor is of great practical importance in food safety and could be widely extended to the detection of other toxins by replacing the sequence of the recognition aptamer. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Liquid Biopsy and Therapeutic Targets: Present and Future Issues in Thoracic Oncology

    PubMed Central

    Hofman, Paul

    2017-01-01

    The practice of liquid biopsy (LB) has revolutionized the care of patients with metastatic lung cancer. Many oncologists now use this approach in daily practice, applying precise procedures for the detection of activating or resistance mutations in EGFR. These tests are performed with plasma DNA and have been approved as companion diagnostic test for patients treated with tyrosine kinase inhibitors. ALK is another important target in lung cancer since it leads to treatment of patients who are positive for a rearrangement in ALK identified with tumor tissue. By analogy with EGFR, LB for detection of genomic alterations in ALK (rearrangements or mutations) has been rapidly adopted in the clinic. However, this promising approach has some limitations and has not yet been disseminated as much as the blood test targeting EGFR. In addition to these two therapeutic targets LB can be used for evaluation of the genomic status of other genes of interest of patients with lung cancer (ROS1, RET, NTRK MET, BRAF, HER2, etc.). LB can be performed to evaluate a specific target or for a more or less complex panel of genes. Considering the number of potential targets for clinical trials, techniques of next-generation sequencing of circulating DNA are on the rise. This review will provide an update on the contribution of LB to care of patients with metastatic lung cancer, including the present limits of this approach, and will consider certain perspectives. PMID:29125548

  8. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification.

    PubMed

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64 °C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 10(3) cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 10(3) cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness.

  9. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification

    PubMed Central

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64°C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 103 cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 103 cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness. PMID:26208001

  10. Detection of diethylene glycol adulteration in propylene glycol--method validation through a multi-instrument collaborative study.

    PubMed

    Li, Xiang; Arzhantsev, Sergey; Kauffman, John F; Spencer, John A

    2011-04-05

    Four portable NIR instruments from the same manufacturer that were nominally identical were programmed with a PLS model for the detection of diethylene glycol (DEG) contamination in propylene glycol (PG)-water mixtures. The model was developed on one spectrometer and used on other units after a calibration transfer procedure that used piecewise direct standardization. Although quantitative results were produced, in practice the instrument interface was programmed to report in Pass/Fail mode. The Pass/Fail determinations were made within 10s and were based on a threshold that passed a blank sample with 95% confidence. The detection limit was then established as the concentration at which a sample would fail with 95% confidence. For a 1% DEG threshold one false negative (Type II) and eight false positive (Type I) errors were found in over 500 samples measured. A representative test set produced standard errors of less than 2%. Since the range of diethylene glycol for economically motivated adulteration (EMA) is expected to be above 1%, the sensitivity of field calibrated portable NIR instruments is sufficient to rapidly screen out potentially problematic materials. Following method development, the instruments were shipped to different sites around the country for a collaborative study with a fixed protocol to be carried out by different analysts. NIR spectra of replicate sets of calibration transfer, system suitability and test samples were all processed with the same chemometric model on multiple instruments to determine the overall analytical precision of the method. The combined results collected for all participants were statistically analyzed to determine a limit of detection (2.0% DEG) and limit of quantitation (6.5%) that can be expected for a method distributed to multiple field laboratories. Published by Elsevier B.V.

  11. Bull trout (Salvelinus confluentus) movement in relation to water temperature, season, and habitat features in Arrowrock Reservoir, Idaho, 2012

    USGS Publications Warehouse

    Maret, Terry R.; Schultz, Justin E.

    2013-01-01

    Acoustic telemetry was used to determine spring to summer (April–August) movement and habitat use of bull trout (Salvelinus confluentus) in Arrowrock Reservoir (hereafter “Arrowrock”), a highly regulated reservoir in the Boise River Basin of southwestern Idaho. Water management practices annually use about 86 percent of the reservoir water volume to satisfy downstream water demands. These practices might be limiting bull trout habitat and movement patterns. Bull trout are among the more thermally sensitive coldwater species in North America, and the species is listed as threatened throughout the contiguous United States under the Endangered Species Act. Biweekly water-temperature and dissolved-oxygen profiles were collected by the Bureau of Reclamation at three locations in Arrowrock to characterize habitat conditions for bull trout. Continuous streamflow and water temperature also were measured immediately upstream of the reservoir on the Middle and South Fork Boise Rivers, which influence habitat conditions in the riverine zones of the reservoir. In spring 2012, 18 bull trout ranging in total length from 306 to 630 millimeters were fitted with acoustic transmitters equipped with temperature and depth sensors. Mobile boat tracking and fixed receivers were used to detect released fish. Fish were tagged from March 28 to April 20 and were tracked through most of August. Most bull trout movements were detected in the Middle Fork Boise River arm of the reservoir. Fifteen individual fish were detected at least once after release. Water surface temperature at each fish detection location ranged from 6.0 to 16.2 degrees Celsius (°C) (mean=10.1°C), whereas bull trout body temperatures were colder, ranging from 4.4 to 11.6°C (mean=7.3°C). Bull trout were detected over deep-water habitat, ranging from 8.0 to 42.6 meters (m) (mean=18.1 m). Actual fish depths were shallower than total water depth, ranging from 0.0 to 24.5 m (mean=6.7 m). The last bull trout was detected in early June, suggesting that fish used little, if any, summertime habitat within the reservoir. Water-quality profile measurements indicated that temperature could limit bull trout use of the reservoir during warm, summer months that coincide with decreased water volume. Thermal refuge during this study appeared to be limited based on scarcity of water that was 15°C and cooler. From the first week of August through the latter part of September, little if any suitable habitat remained for bull trout, with most temperatures exceeding 15°C at all locations where water quality profiles were measured.

  12. Breath acetone as a potential marker in clinical practice.

    PubMed

    Ruzsányi, Veronika; Péter Kalapos, Miklós

    2017-06-01

    In recent decades, two facts have changed the opinion of researchers about the function of acetone in humans. Firstly, it has turned out that acetone cannot be regarded as simply a waste product of metabolism, because there are several pathways in which acetone is produced or broken down. Secondly, methods have emerged making possible its detection in exhaled breath, thereby offering an attractive alternative to investigation of blood and urine samples. From a clinical point of view the measurement of breath acetone levels is important, but there are limitations to its wide application. These limitations can be divided into two classes, technical and biological limits. The technical limits include the storage of samples, detection threshold, standardization of clinical settings, and the price of instruments. When considering the biological ranges of acetone, personal factors such as race, age, gender, weight, food consumption, medication, illicit drugs, and even profession/class have to be taken into account to use concentration information for disorders. In some diseases such as diabetes mellitus and lung cancer, as well as in nutrition-related behavior such as starvation and ketogenic diet, breath acetone has been extensively examined. At the same time, there is a lack of investigations in other cases in which ketosis is also evident, such as in alcoholism or an inborn error of metabolism. In summary, the detection of acetone in exhaled breath is a useful and promising tool for diagnosis and it can be used as a marker to follow the effectiveness of treatments in some disorders. However, further endeavors are needed for clarification of the exact distribution of acetone in different body compartments and evaluation of its complex role in humans, especially in those cases in which a ketotic state also occurs.

  13. Brain Monitoring with Electroencephalography and the Electroencephalogram-Derived Bispectral Index During Cardiac Surgery

    PubMed Central

    Kertai, Miklos D.; Whitlock, Elizabeth L.; Avidan, Michael S.

    2011-01-01

    Cardiac surgery presents particular challenges for the anesthesiologist. In addition to standard and advanced monitors typically used during cardiac surgery, anesthesiologists may consider monitoring the brain with raw or processed electroencephalography (EEG). There is strong evidence that a protocol incorporating the processed EEG Bispectral Index (BIS) decreases the incidence intraoperative awareness compared with standard practice. However there is conflicting evidence that incorporating the BIS into cardiac anesthesia practice improves “fast-tracking,” decreases anesthetic drug use, or detects cerebral ischemia. Recent research, including many cardiac surgical patients, shows that a protocol based on BIS monitoring is not superior to a protocol based on end tidal anesthetic concentration monitoring in preventing awareness. There has been a resurgence of interest in the anesthesia literature in limited montage EEG monitoring, including nonproprietary processed indices. This has been accompanied by research showing that with structured training, anesthesiologists can glean useful information from the raw EEG trace. In this review, we discuss both the hypothesized benefits and limitations of BIS and frontal channel EEG monitoring in the cardiac surgical population. PMID:22253267

  14. Observations on military exploitation of explosives detection technologies

    NASA Astrophysics Data System (ADS)

    Faust, Anthony A.; de Ruiter, C. J.; Ehlerding, Anneli; McFee, John E.; Svinsås, Eirik; van Rheenen, Arthur D.

    2011-06-01

    Accurate and timely detection of explosives, energetic materials, and their associated compounds would provide valuable information to military commanders in a wide range of military operations: protection of fast moving convoys from mobile or static IED threats; more deliberate countermine and counter-IED operations during route or area clearance; and static roles such as hasty or deliberate checkpoints, critical infrastructure protection and support to public security. The detection of hidden explosive hazards is an extremely challenging problem, as evidenced by the fact that related research has been ongoing in many countries for at least seven decades and no general purpose solution has yet been found. Technologies investigated have spanned all major scientific fields, with emphasis on the physical sciences, life sciences, engineering, robotics, computer technology and mathematics. This paper will present a limited, operationally-focused overview of the current status of detection technologies. Emphasis will be on those technologies that directly detect the explosive hazard, as opposed to those that detect secondary properties of the threat, such as the casing, associated wires or electronics. Technologies that detect explosives include those based on nuclear radiation and terahertz radiation, as well as trace and biological detection techniques. Current research areas of the authors will be used to illustrate the practical applications.

  15. Theoretical detection threshold of the proton-acoustic range verification technique.

    PubMed

    Ahmad, Moiz; Xiang, Liangzhong; Yousefi, Siavash; Xing, Lei

    2015-10-01

    Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1-10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. The calculated noise in the transducer was 12-28 mPa, depending on the transducer central frequency (70-380 kHz). The minimum number of protons detectable by the technique was on the order of 3-30 × 10(6) per pulse, with 30-800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10(6) protons/pulse and beam current.

  16. Theoretical detection threshold of the proton-acoustic range verification technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, Moiz; Yousefi, Siavash; Xing, Lei, E-mail: lei@stanford.edu

    2015-10-15

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method.more » Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10{sup 6} protons/pulse and beam current.« less

  17. Theoretical detection threshold of the proton-acoustic range verification technique

    PubMed Central

    Ahmad, Moiz; Xiang, Liangzhong; Yousefi, Siavash; Xing, Lei

    2015-01-01

    Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 106 per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 106 protons/pulse and beam current. PMID:26429247

  18. An automatic detection software for differential reflection spectroscopy

    NASA Astrophysics Data System (ADS)

    Yuksel, Seniha Esen; Dubroca, Thierry; Hummel, Rolf E.; Gader, Paul D.

    2012-06-01

    Recent terrorist attacks have sprung a need for a large scale explosive detector. Our group has developed differential reflection spectroscopy which can detect explosive residue on surfaces such as parcel, cargo and luggage. In short, broad band ultra-violet and visible light is shone onto a material (such as a parcel) moving on a conveyor belt. Upon reflection off the surface, the light intensity is recorded with a spectrograph (spectrometer in combination with a CCD camera). This reflected light intensity is then subtracted and normalized with the next data point collected, resulting in differential reflection spectra in the 200-500 nm range. Explosives show spectral finger-prints at specific wavelengths, for example, the spectrum of 2,4,6, trinitrotoluene (TNT) shows an absorption edge at 420 nm. Additionally, we have developed an automated software which detects the characteristic features of explosives. One of the biggest challenges for the algorithm is to reach a practical limit of detection. In this study, we introduce our automatic detection software which is a combination of principal component analysis and support vector machines. Finally we present the sensitivity and selectivity response of our algorithm as a function of the amount of explosive detected on a given surface.

  19. Label-Free Nanopore Biosensor for Rapid and Highly Sensitive Cocaine Detection in Complex Biological Fluids.

    PubMed

    Rauf, Sana; Zhang, Ling; Ali, Asghar; Liu, Yang; Li, Jinghong

    2017-02-24

    Detection of very low amounts of illicit drugs such as cocaine in clinical fluids like serum continues to be important for many areas in the fight against drug trafficking. Herein, we constructed a label-free nanopore biosensor for rapid and highly sensitive detection of cocaine in human serum and saliva samples based on target-induced strand release strategy. In this bioassay, an aptamer for cocaine was prehybridized with a short complementary DNA. Owing to cocaine specific binding with aptamer, the short DNA strand was displaced from aptamer and translocation of this output DNA through α-hemolysin nanopore generated distinct spike-like current blockages. When plotted in double-logarithmic scale, a linear relationship between target cocaine concentration and output DNA event frequency was obtained in a wide concentration range from 50 nM to 100 μM of cocaine, with the limit of detection down to 50 nM. In addition, this aptamer-based sensor method was successfully applied for cocaine detection in complex biological fluids like human saliva and serum samples with great selectivity. Simple preparation, low cost, rapid, label-free, and real sample detection are the motivating factors for practical application of the proposed biosensor.

  20. Experimental investigation of observation error in anuran call surveys

    USGS Publications Warehouse

    McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.

    2010-01-01

    Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.

  1. Integrated Magneto-Chemical Sensor For On-Site Food Allergen Detection.

    PubMed

    Lin, Hsing-Ying; Huang, Chen-Han; Park, Jongmin; Pathania, Divya; Castro, Cesar M; Fasano, Alessio; Weissleder, Ralph; Lee, Hakho

    2017-10-24

    Adverse food reactions, including food allergies, food sensitivities, and autoimmune reaction (e.g., celiac disease) affect 5-15% of the population and remain a considerable public health problem requiring stringent food avoidance and epinephrine availability for emergency events. Avoiding problematic foods is practically difficult, given current reliance on prepared foods and out-of-home meals. In response, we developed a portable, point-of-use detection technology, termed integrated exogenous antigen testing (iEAT). The system consists of a disposable antigen extraction device coupled with an electronic keychain reader for rapid sensing and communication. We optimized the prototype iEAT system to detect five major food antigens in peanuts, hazelnuts, wheat, milk, and eggs. Antigen extraction and detection with iEAT requires <10 min and achieves high-detection sensitivities (e.g., 0.1 mg/kg for gluten, lower than regulatory limits of 20 mg/kg). When testing under restaurant conditions, we were able to detect hidden food antigens such as gluten within "gluten-free" food items. The small size and rapid, simple testing of the iEAT system should help not only consumers but also other key stakeholders such as clinicians, food industries, and regulators to enhance food safety.

  2. Compressor stability management

    NASA Astrophysics Data System (ADS)

    Dhingra, Manuj

    Dynamic compressors are susceptible to aerodynamic instabilities while operating at low mass flow rates. These instabilities, rotating stall and surge, are detrimental to engine life and operational safety, and are thus undesirable. In order to prevent stability problems, a passive technique, involving fuel flow scheduling, is currently employed on gas turbines. The passive nature of this technique necessitates conservative stability margins, compromising performance and/or efficiency. In the past, model based active control has been proposed to enable reduction of margin requirements. However, available compressor stability models do not predict the different stall inception patterns, making model based control techniques practically infeasible. This research presents active stability management as a viable alternative. In particular, a limit detection and avoidance approach has been used to maintain the system free of instabilities. Simulations show significant improvements in the dynamic response of a gas turbine engine with this approach. A novel technique has been developed to enable real-time detection of stability limits in axial compressors. It employs a correlation measure to quantify the chaos in the rotor tip region. Analysis of data from four axial compressors shows that the value of the correlation measure decreases as compressor loading is increased. Moreover, sharp drops in this measure have been found to be relevant for stability limit detection. The significance of these drops can be captured by tracking events generated by the downward crossing of a selected threshold level. It has been observed that the average number of events increases as the stability limit is approached in all the compressors studied. These events appear to be randomly distributed in time. A stochastic model for the time between consecutive events has been developed and incorporated in an engine simulation. The simulation has been used to highlight the importance of the threshold level to successful stability management. The compressor stability management concepts have also been experimentally demonstrated on a laboratory axial compressor rig. The fundamental nature of correlation measure has opened avenues for its application besides limit detection. The applications presented include stage load matching in a multi-stage compressor and monitoring the aerodynamic health of rotor blades.

  3. Based on time and spatial-resolved SERS mapping strategies for detection of pesticides.

    PubMed

    Ma, Bingbing; Li, Pan; Yang, Liangbao; Liu, Jinhuai

    2015-08-15

    For the sensitive and convenient detection of pesticides, several sensing methods and materials have been widely explored. However, it is still a challenge to obtain sensitive, simple detection techniques for pesticides. Here, the simple and sensitive Time-resolved SERS mapping (T-SERS) and Spatial-resolved SERS mapping (S-SERS) are presented for detection of pesticides by using Au@Ag NPs as SERS substrate. The Time-resolved SERS mapping (T-SERS) is based on state translation nanoparticles from the wet state to the dry state to realize SERS measurements. During the SERS measurement, adhesive force drives the particles closer together and then average interparticle gap becomes smaller. Following, air then begins to intersperse into the liquid network and the particles are held together by adhesive forces at the solid-liquid-air interface. In the late stage of water evaporation, all particles are uniformly distributed. Thus, so called hotspots matrix that can hold hotspots between every two adjacent particles in efficient space with minimal polydispersity of particle size are achieved, accompanying the red-shift of surface plasmon peak and appearance of an optimal SPR resonated sharply with excitation wavelength. Here, we found that the T-SERS method exhibits the detection limits of 1-2 orders of magnitude higher than that of S-SERS. On the other hand, the T-SERS is very simple method with high detection sensitivity, better reproducibility (RSD=10.8%) and is beneficial to construction of a calibration curve in comparison with that of Spatial-resolved SERS mapping (S-SERS). Most importantly, as a result of its remarkable sensitivity, T-SERS mapping strategies have been applied to detection of several pesticides and the detect limit can down to 1nM for paraoxon, 0.5nM for sumithion. In short, T-SERS mapping measurement promises to open a market for SERS practical detection with prominent advantages. Copyright © 2015. Published by Elsevier B.V.

  4. A novel and practical approach for determination of the acoustic nonlinearity parameter using a pulse-echo method

    NASA Astrophysics Data System (ADS)

    Jeong, Hyunjo; Zhang, Shuzeng; Barnard, Dan; Li, Xiongbing

    2016-02-01

    Measurements of the acoustic nonlinearity parameter β are frequently made for early detection of damage in various materials. The practical implementation of the measurement technique has been limited to the through-transmission setup for determining the nonlinearity parameter of the second harmonic wave. In this work, a feasibility study is performed to assess the possibility of using pulse-echo methods in determining the nonlinearity parameter β of solids with a stress-free boundary. The multi-Gaussian beam model is developed based on the quasilinear theory of the KZK equation. Simulation results and discussion are presented for the reflected beam fields of the fundamental and second harmonic waves, the uncorrected β behavior and the properties of total correction that incorporate reflection, attenuation and diffraction effects.

  5. Two-dimensional distributed-phase-reference protocol for quantum key distribution

    NASA Astrophysics Data System (ADS)

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A. Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-12-01

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable.

  6. Two-dimensional distributed-phase-reference protocol for quantum key distribution.

    PubMed

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-12-22

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable.

  7. Two-dimensional distributed-phase-reference protocol for quantum key distribution

    PubMed Central

    Bacco, Davide; Christensen, Jesper Bjerge; Castaneda, Mario A. Usuga; Ding, Yunhong; Forchhammer, Søren; Rottwitt, Karsten; Oxenløwe, Leif Katsuo

    2016-01-01

    Quantum key distribution (QKD) and quantum communication enable the secure exchange of information between remote parties. Currently, the distributed-phase-reference (DPR) protocols, which are based on weak coherent pulses, are among the most practical solutions for long-range QKD. During the last 10 years, long-distance fiber-based DPR systems have been successfully demonstrated, although fundamental obstacles such as intrinsic channel losses limit their performance. Here, we introduce the first two-dimensional DPR-QKD protocol in which information is encoded in the time and phase of weak coherent pulses. The ability of extracting two bits of information per detection event, enables a higher secret key rate in specific realistic network scenarios. Moreover, despite the use of more dimensions, the proposed protocol remains simple, practical, and fully integrable. PMID:28004821

  8. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... calculated method detection limit. To insure that the estimate of the method detection limit is a good...) where: MDL = the method detection limit t(n-1,1- α=.99) = the students' t value appropriate for a 99... Determination of the Method Detection Limit-Revision 1.11 B Appendix B to Part 136 Protection of Environment...

  9. Material limitations on the detection limit in refractometry.

    PubMed

    Skafte-Pedersen, Peder; Nunes, Pedro S; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  10. Limiting majoron self-interactions from gravitational wave experiments

    NASA Astrophysics Data System (ADS)

    Addazi, Andrea; Marcianò, Antonino

    2018-01-01

    We show how majoron models may be tested/limited in gravitational wave experiments. In particular, the majoron self-interaction potential may induce a first order phase transition, producing gravitational waves from bubble collisions. We dub such a new scenario the violent majoron model, because it would be associated with a violent phase transition in the early Universe. Sphaleron constraints can be avoided if the global U{(1)}B-L is broken at scales lower than the electroweak scale, provided that the B-L spontaneously breaking scale is lower than 10 TeV in order to satisfy the cosmological mass density bound. The possibility of a sub-electroweak phase transition is practically unconstrained by cosmological bounds and it may be detected within the sensitivity of the next generation of gravitational wave experiments: eLISA, DECIGO and BBO. We also comment on its possible detection in the next generation of electron-positron colliders, where majoron production can be observed from the Higgs portals in missing transverse energy channels. Supported by the Shanghai Municipality, through the grant No. KBH1512299, and by Fudan University, through the grant No. JJH1512105

  11. Long-distance continuous-variable quantum key distribution using non-Gaussian state-discrimination detection

    NASA Astrophysics Data System (ADS)

    Liao, Qin; Guo, Ying; Huang, Duan; Huang, Peng; Zeng, Guihua

    2018-02-01

    We propose a long-distance continuous-variable quantum key distribution (CVQKD) with a four-state protocol using non-Gaussian state-discrimination detection. A photon subtraction operation, which is deployed at the transmitter, is used for splitting the signal required for generating the non-Gaussian operation to lengthen the maximum transmission distance of the CVQKD. Whereby an improved state-discrimination detector, which can be deemed as an optimized quantum measurement that allows the discrimination of nonorthogonal coherent states beating the standard quantum limit, is applied at the receiver to codetermine the measurement result with the conventional coherent detector. By tactfully exploiting the multiplexing technique, the resulting signals can be simultaneously transmitted through an untrusted quantum channel, and subsequently sent to the state-discrimination detector and coherent detector, respectively. Security analysis shows that the proposed scheme can lengthen the maximum transmission distance up to hundreds of kilometers. Furthermore, by taking the finite-size effect and composable security into account we obtain the tightest bound of the secure distance, which is more practical than that obtained in the asymptotic limit.

  12. Sol-gel immobilized short-chain poly(ethylene glycol) coating for capillary microextraction of underivatized polar analytes.

    PubMed

    Kulkarni, Sameer; Shearrow, Anne M; Malik, Abdul

    2007-12-07

    Sol-gel coating with covalently bonded low-molecular-weight (MW<300 Da) poly(ethylene glycol) (PEG) chains was developed for capillary microextraction (CME). The sol-gel chemistry proved effective in the immobilization of low-molecular-weight PEGs thanks to the formation of chemical bonds between the organic-inorganic hybrid sol-gel PEG coating and the fused silica capillary inner surface. This chemical anchorage provided excellent thermal and solvent stability to the created sol-gel PEG coating as is evidenced by its high upper limit of allowable conditioning temperature (340 degrees C) and its practically identical performance before and after rinsing with various solvents. The prepared sol-gel PEG coating provided simultaneous extraction of moderately polar and highly polar analytes from aqueous samples without requiring derivatization, pH adjustment or salting-out procedures. Detection limits on the order of nanogram per liter (ng/L) were achieved in CME-GC-flame ionization detection experiments designed for the preconcentration and trace analysis of both highly polar and moderately polar compounds extracted directly from aqueous media using sol-gel short-chain PEG coated microextraction capillaries.

  13. Intestinal Carriage of Carbapenemase-Producing Organisms: Current Status of Surveillance Methods

    PubMed Central

    Jacobs, Michael R.; Wilson, Brigid; Kaye, Keith; Donskey, Curtis J.; Perez, Federico

    2015-01-01

    SUMMARY Carbapenemases have become a significant mechanism for broad-spectrum β-lactam resistance in Enterobacteriaceae and other Gram-negative bacteria such as Pseudomonas and Acinetobacter spp. Intestinal carriage of carbapenemase-producing organisms (CPOs) is an important source of transmission. Isolation of carriers is one strategy that can be used to limit the spread of these bacteria. In this review, we critically examine the clinical performance, advantages, and disadvantages of methods available for the detection of intestinal carriage of CPOs. Culture-based methods (Centers for Disease Control and Prevention [CDC] protocols, chromogenic media, specialized agars, and double-disk synergy tests) for detecting carriage of CPOs are convenient due to their ready availability and low cost, but their limited sensitivity and long turnaround time may not always be optimal for infection control practices. Contemporary nucleic acid amplification techniques (NAATs) such as real-time PCR, hybridization assays, loop-mediated isothermal amplification (LAMP), or a combined culture and NAAT approach may provide fast results and/or added sensitivity and specificity compared with culture-based methods. Infection control practitioners and clinical microbiologists should be aware of the strengths and limitations of available methods to determine the most suitable approach for their medical facility to fit their infection control needs. PMID:26511484

  14. A Review of Oil Spill Remote Sensing

    PubMed Central

    Brown, Carl E.

    2017-01-01

    The technical aspects of oil spill remote sensing are examined and the practical uses and drawbacks of each technology are given with a focus on unfolding technology. The use of visible techniques is ubiquitous, but limited to certain observational conditions and simple applications. Infrared cameras offer some potential as oil spill sensors but have several limitations. Both techniques, although limited in capability, are widely used because of their increasing economy. The laser fluorosensor uniquely detects oil on substrates that include shoreline, water, soil, plants, ice, and snow. New commercial units have come out in the last few years. Radar detects calm areas on water and thus oil on water, because oil will reduce capillary waves on a water surface given moderate winds. Radar provides a unique option for wide area surveillance, all day or night and rainy/cloudy weather. Satellite-carried radars with their frequent overpass and high spatial resolution make these day–night and all-weather sensors essential for delineating both large spills and monitoring ship and platform oil discharges. Most strategic oil spill mapping is now being carried out using radar. Slick thickness measurements have been sought for many years. The operative technique at this time is the passive microwave. New techniques for calibration and verification have made these instruments more reliable. PMID:29301212

  15. A Review of Oil Spill Remote Sensing.

    PubMed

    Fingas, Merv; Brown, Carl E

    2017-12-30

    The technical aspects of oil spill remote sensing are examined and the practical uses and drawbacks of each technology are given with a focus on unfolding technology. The use of visible techniques is ubiquitous, but limited to certain observational conditions and simple applications. Infrared cameras offer some potential as oil spill sensors but have several limitations. Both techniques, although limited in capability, are widely used because of their increasing economy. The laser fluorosensor uniquely detects oil on substrates that include shoreline, water, soil, plants, ice, and snow. New commercial units have come out in the last few years. Radar detects calm areas on water and thus oil on water, because oil will reduce capillary waves on a water surface given moderate winds. Radar provides a unique option for wide area surveillance, all day or night and rainy/cloudy weather. Satellite-carried radars with their frequent overpass and high spatial resolution make these day-night and all-weather sensors essential for delineating both large spills and monitoring ship and platform oil discharges. Most strategic oil spill mapping is now being carried out using radar. Slick thickness measurements have been sought for many years. The operative technique at this time is the passive microwave. New techniques for calibration and verification have made these instruments more reliable.

  16. Determination of Ten Macrolide Drugs in Environmental Water Using Molecularly Imprinted Solid-Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Song, Xuqin; Zhou, Tong; Li, Jiufeng; Zhang, Meiyu; Xie, Jingmeng; He, Limin

    2018-05-14

    With the extensive application of antibiotics in livestock, their contamination of the aquatic environment has received more attention. Molecularly imprinted polymer (MIP), as an eco-friendly and durable solid-phase extraction material, has shown great potential for the separation and enrichment of antibiotics in water. This study aims at developing a practical and economical method based on molecularly imprinted solid phase extraction (MISPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously detecting ten macrolide drugs in different sources of water samples. The MIP was synthesized by bulk polymerization using tylosin as the template and methacrylic acid as the functional monomer. The MIP exhibited a favorable load-bearing capacity for water (>90 mL), which is more than triple that of non-molecularly imprinted polymers (NIP). The mean recoveries of macrolides at four spiked concentration levels (limit of quantification, 40, 100, and 400 ng/L) were 62.6⁻100.9%, with intra-day and inter-day relative standard deviations below 12.6%. The limit of detection and limit of quantification were 1.0⁻15.0 ng/L and 3.0⁻40.0 ng/L, respectively. Finally, the proposed method was successfully applied to the analysis of real water samples.

  17. Effect of Routine Surveillance Imaging on the Outcomes of Patients With Classical Hodgkin Lymphoma After Autologous Hematopoietic Cell Transplantation.

    PubMed

    Kapke, Jonathan T; Epperla, Narendranath; Shah, Namrata; Richardson, Kristin; Carrum, George; Hari, Parameswaran N; Pingali, Sai R; Hamadani, Mehdi; Karmali, Reem; Fenske, Timothy S

    2017-07-01

    Patients with relapsed and refractory classical Hodgkin lymphoma (cHL) are often treated with autologous hematopoietic cell transplantation (auto-HCT). After auto-HCT, most transplant centers implement routine surveillance imaging to monitor for disease relapse; however, there is limited evidence to support this practice. In this multicenter, retrospective study, we identified cHL patients (n = 128) who received auto-HCT, achieved complete remission (CR) after transplantation, and then were followed with routine surveillance imaging. Of these, 29 (23%) relapsed after day 100 after auto-HCT. Relapse was detected clinically in 14 patients and with routine surveillance imaging in 15 patients. When clinically detected relapse was compared with to radiographically detected relapse respectively, the median overall survival (2084 days [range, 225-4161] vs. 2737 days [range, 172-2750]; P = .51), the median time to relapse (247 days [range, 141-3974] vs. 814 days [range, 96-1682]; P = .30) and the median postrelapse survival (674 days [range, 13-1883] vs. 1146 days [range, 4-2548]; P = .52) were not statistically different. In patients who never relapsed after auto-HCT, a median of 4 (range, 1-25) surveillance imaging studies were performed over a median follow-up period of 3.5 years. A minority of patients with cHL who achieve CR after auto-HCT will ultimately relapse. Surveillance imaging detected approximately half of relapses; however, outcomes were similar for those whose relapse was detected using routine surveillance imaging versus detected clinically in between surveillance imaging studies. There appears to be limited utility for routine surveillance imaging in cHL patients who achieve CR after auto-HCT. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    NASA Astrophysics Data System (ADS)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  19. Annoyance, detection and recognition of wind turbine noise.

    PubMed

    Van Renterghem, Timothy; Bockstael, Annelies; De Weirt, Valentine; Botteldooren, Dick

    2013-07-01

    Annoyance, recognition and detection of noise from a single wind turbine were studied by means of a two-stage listening experiment with 50 participants with normal hearing abilities. In-situ recordings made at close distance from a 1.8-MW wind turbine operating at 22 rpm were mixed with road traffic noise, and processed to simulate indoor sound pressure levels at LAeq 40 dBA. In a first part, where people were unaware of the true purpose of the experiment, samples were played during a quiet leisure activity. Under these conditions, pure wind turbine noise gave very similar annoyance ratings as unmixed highway noise at the same equivalent level, while annoyance by local road traffic noise was significantly higher. In a second experiment, listeners were asked to identify the sample containing wind turbine noise in a paired comparison test. The detection limit of wind turbine noise in presence of highway noise was estimated to be as low as a signal-to-noise ratio of -23 dBA. When mixed with local road traffic, such a detection limit could not be determined. These findings support that noticing the sound could be an important aspect of wind turbine noise annoyance at the low equivalent levels typically observed indoors in practice. Participants that easily recognized wind-turbine(-like) sounds could detect wind turbine noise better when submersed in road traffic noise. Recognition of wind turbine sounds is also linked to higher annoyance. Awareness of the source is therefore a relevant aspect of wind turbine noise perception which is consistent with previous research. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. State of the art in hair analysis for detection of drug and alcohol abuse.

    PubMed

    Pragst, Fritz; Balikova, Marie A

    2006-08-01

    Hair differs from other materials used for toxicological analysis because of its unique ability to serve as a long-term storage of foreign substances with respect to the temporal appearance in blood. Over the last 20 years, hair testing has gained increasing attention and recognition for the retrospective investigation of chronic drug abuse as well as intentional or unintentional poisoning. In this paper, we review the physiological basics of hair growth, mechanisms of substance incorporation, analytical methods, result interpretation and practical applications of hair analysis for drugs and other organic substances. Improved chromatographic-mass spectrometric techniques with increased selectivity and sensitivity and new methods of sample preparation have improved detection limits from the ng/mg range to below pg/mg. These technical advances have substantially enhanced the ability to detect numerous drugs and other poisons in hair. For example, it was possible to detect previous administration of a single very low dose in drug-facilitated crimes. In addition to its potential application in large scale workplace drug testing and driving ability examination, hair analysis is also used for detection of gestational drug exposure, cases of criminal liability of drug addicts, diagnosis of chronic intoxication and in postmortem toxicology. Hair has only limited relevance in therapy compliance control. Fatty acid ethyl esters and ethyl glucuronide in hair have proven to be suitable markers for alcohol abuse. Hair analysis for drugs is, however, not a simple routine procedure and needs substantial guidelines throughout the testing process, i.e., from sample collection to results interpretation.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faidy, C.

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  2. [Resistant hypertension by unadvertised non-compliance detected by psychiatric expertise and drug dosages].

    PubMed

    Didier, R; Gilard, M; Denolle, T

    2018-06-01

    The management of patients with resistant hypertension remains a major challenge in daily clinical practice in order to limit macro and microvascular impact. However, lack of compliance often remains one of the main etiologies of resistant hypertension. Through a clinical case of complex therapeutic non-compliance, we will detail the frequency, the screening and the management of therapeutic non-compliance. Finally, we will specify the contribution of drug dosages and psychological expertise in screening non-observant patients with presumed resistant hypertension. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  3. Analysis of a novel sensor interrogation technique based on fiber cavity ring-down (CRD) loop and OTDR

    NASA Astrophysics Data System (ADS)

    Yüksel, Kivilcim; Yilmaz, Anil

    2018-07-01

    We present the analysis of a remote sensor based on fiber Cavity Ring-Down (CRD) loop interrogated by an Optical Time Domain Reflectometer (OTDR) taking into account both practical limitations and the related signal processing. A commercial OTDR is used for both pulse generation and sensor output detection. This allows obtaining a compact and simple design for intensity-based sensor applications. This novel sensor interrogation approach is experimentally demonstrated by placing a variable attenuator inside the fiber loop that mimics a sensor head.

  4. A colorimetric turn-on optical chemosensor for Cu2+ ions and its application as solid state sensor

    NASA Astrophysics Data System (ADS)

    Pannipara, Mehboobali; Al-Sehemi, Abdullah G.; Assiri, Mohammed; Kalam, Abul

    2018-05-01

    We report a novel coumarin based optical chemosensor (Probe 1) for the selective and sensitive detection of Cu2+ ions in aqueous medium. The addition of Cu2+ ions to Probe 1 shows distinct color change from light yellow to pinkish red color under visible light with the sensing limit of 1.54 μM. Moreover, practical utility of Probe 1 as solid state optical sensor (test paper, TLC plates) for sensing Cu2+ has been demonstrated by instantaneous "naked eye" response.

  5. Decision support methods for the detection of adverse events in post-marketing data.

    PubMed

    Hauben, M; Bate, A

    2009-04-01

    Spontaneous reporting is a crucial component of post-marketing drug safety surveillance despite its significant limitations. The size and complexity of some spontaneous reporting system databases represent a challenge for drug safety professionals who traditionally have relied heavily on the scientific and clinical acumen of the prepared mind. Computer algorithms that calculate statistical measures of reporting frequency for huge numbers of drug-event combinations are increasingly used to support pharamcovigilance analysts screening large spontaneous reporting system databases. After an overview of pharmacovigilance and spontaneous reporting systems, we discuss the theory and application of contemporary computer algorithms in regular use, those under development, and the practical considerations involved in the implementation of computer algorithms within a comprehensive and holistic drug safety signal detection program.

  6. Sagnac-interferometer-based fresnel flow probe.

    PubMed

    Tselikov, A; Blake, J

    1998-10-01

    We used a near-diffraction-limited flow or light-wave-interaction pipe to produce a Sagnac-interferometer-based Fresnel drag fluid flowmeter capable of detecting extremely small flow rates. An optimized design of the pipe along with the use of a state-of-the-art Sagnac interferometer results in a minimum-detectable water flow rate of 2.4 nl/s [1 drop/(5 h)]. The flowmeter's capability of measuring the water consumption by a small plant in real time has been demonstrated. We then designed an automated alignment system that finds and maintains the optimum fiber-coupling regime, which makes the applications of the Fresnel-drag-based flowmeters practical, especially if the length of the interaction pipe is long. Finally, we have applied the automatic alignment technique to an air flowmeter.

  7. Probing the gravitational Faraday rotation using quasar X-ray microlensing.

    PubMed

    Chen, Bin

    2015-11-17

    The effect of gravitational Faraday rotation was predicted in the 1950s, but there is currently no practical method for measuring this effect. Measuring this effect is important because it will provide new evidence for correctness of general relativity, in particular, in the strong field limit. We predict that the observed degree and angle of the X-ray polarization of a cosmologically distant quasar microlensed by the random star field in a foreground galaxy or cluster lens vary rapidly and concurrently with flux during caustic-crossing events using the first simulation of quasar X-ray microlensing polarization light curves. Therefore, it is possible to detect gravitational Faraday rotation by monitoring the X-ray polarization of gravitationally microlensed quasars. Detecting this effect will also confirm the strong gravity nature of quasar X-ray emission.

  8. What is the current practice of therapists in the measurement of somatosensation in children with cerebral palsy and other neurological disorders?

    PubMed

    Walmsley, Corrin; Taylor, Susan; Parkins, Timothy; Carey, Leeanne; Girdler, Sonya; Elliott, Catherine

    2018-04-01

    Somatosensation is the ability to detect and recognise body sensations such as touch, vibration, pressure, pain, temperature and proprioception. Cerebral palsy is a neurological disorder that is often accompanied by impairments in somatosensation. Current somatosensory assessments have limited psychometrics established for use with these children. The aim of this study was to identify therapists' current practice and perspectives related to the assessment of somatosensation in children with neurological disorders. A cross-sectional questionnaire was used to identify the somatosensory assessments currently used in clinical practice, time allocated to assessment, and therapists' satisfaction and confidence using the available assessments of somatosensation. The questionnaire was adapted from a previously utilised questionnaire that identified therapists' use of somatosensory assessments with adults post-stroke. A total of 135 therapists responded to the questionnaire. Seventy-nine (92%) occupational therapists and 44 (89.7%) physiotherapists indicated that they currently assessed or treated children with somatosensory deficits. Sixty-four (82.1%) occupational therapists and 38 (86.3%) physiotherapists regarded assessment of somatosensation in children with neurological disorders as important to very important. However, only seven (8.8%) occupational therapists and seven (15.9%) physiotherapists reported confidence in their ability to do so. The methods with which therapists detect and measure somatosensory impairment in children with neurological disorders are variable, with non-standardised and/or informal assessments most frequently used. Despite there being recommendations of best practice for the assessment of specific domains of somatosensation in children with cerebral palsy, current practice does not yet mirror these recommendations. Additionally, therapists have low satisfaction and confidence with what they are currently using, highlighting the need for a comprehensive and standardised assessment of somatosensation for use in children with neurological disorders. © 2017 Occupational Therapy Australia.

  9. Material Limitations on the Detection Limit in Refractometry

    PubMed Central

    Skafte-Pedersen, Peder; Nunes, Pedro S.; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly. PMID:22291513

  10. Clinical testing of BRCA1 and BRCA2: a worldwide snapshot of technological practices.

    PubMed

    Toland, Amanda Ewart; Forman, Andrea; Couch, Fergus J; Culver, Julie O; Eccles, Diana M; Foulkes, William D; Hogervorst, Frans B L; Houdayer, Claude; Levy-Lahad, Ephrat; Monteiro, Alvaro N; Neuhausen, Susan L; Plon, Sharon E; Sharan, Shyam K; Spurdle, Amanda B; Szabo, Csilla; Brody, Lawrence C

    2018-01-01

    Clinical testing of BRCA1 and BRCA2 began over 20 years ago. With the expiration and overturning of the BRCA patents, limitations on which laboratories could offer commercial testing were lifted. These legal changes occurred approximately the same time as the widespread adoption of massively parallel sequencing (MPS) technologies. Little is known about how these changes impacted laboratory practices for detecting genetic alterations in hereditary breast and ovarian cancer genes. Therefore, we sought to examine current laboratory genetic testing practices for BRCA1 / BRCA2 . We employed an online survey of 65 questions covering four areas: laboratory characteristics, details on technological methods, variant classification, and client-support information. Eight United States (US) laboratories and 78 non-US laboratories completed the survey. Most laboratories (93%; 80/86) used MPS platforms to identify variants. Laboratories differed widely on: (1) technologies used for large rearrangement detection; (2) criteria for minimum read depths; (3) non-coding regions sequenced; (4) variant classification criteria and approaches; (5) testing volume ranging from 2 to 2.5 × 10 5 tests annually; and (6) deposition of variants into public databases. These data may be useful for national and international agencies to set recommendations for quality standards for BRCA1/BRCA2 clinical testing. These standards could also be applied to testing of other disease genes.

  11. Microfluidic Capillaric Circuit for Rapid and Facile Bacteria Detection.

    PubMed

    Olanrewaju, Ayokunle Oluwafemi; Ng, Andy; DeCorwin-Martin, Philippe; Robillard, Alessandra; Juncker, David

    2017-06-20

    Urinary tract infections (UTI) are one of the most common bacterial infections and would greatly benefit from a rapid point-of-care diagnostic test. Although significant progress has been made in developing microfluidic systems for nucleic acid and whole bacteria immunoassay tests, their practical application is limited by complex protocols, bulky peripherals, and slow operation. Here we present a microfluidic capillaric circuit (CC) optimized for rapid and automated detection of bacteria in urine. Molds for CCs were constructed using previously established design rules, then 3D-printed and replicated into poly(dimethylsiloxane). CCs autonomously and sequentially performed all liquid delivery steps required for the assay. For efficient bacteria capture, on-the-spot packing of antibody-functionalized microbeads was completed in <20 s followed by autonomous sequential delivery of 100 μL of bacteria sample, biotinylated detection antibodies, fluorescent streptavidin conjugate, and wash buffer for a total volume ≈115 μL. The assay was completed in <7 min. Fluorescence images of the microbead column revealed captured bacteria as bright spots that were easily counted manually or using an automated script for user-independent assay readout. The limit of detection of E. coli in synthetic urine was 1.2 × 10 2 colony-forming-units per mL (CFU/mL), which is well below the clinical diagnostic criterion (>10 5 CFU/mL) for UTI. The self-powered, peripheral-free CC presented here has potential for use in rapid point-of-care UTI screening.

  12. Quantitative detection method for Roundup Ready soybean in food using duplex real-time PCR MGB chemistry.

    PubMed

    Samson, Maria Cristina; Gullì, Mariolina; Marmiroli, Nelson

    2010-07-01

    Methodologies that enable the detection of genetically modified organisms (GMOs) (authorized and non-authorized) in food and feed strongly influence the potential for adequate updating and implementation of legislation together with labeling requirements. Quantitative polymerase chain reaction (qPCR) systems were designed to boost the sensitivity and specificity on the identification of GMOs in highly degraded DNA samples; however, such testing will become economically difficult to cope with due to increasing numbers of approved genetically modified (GM) lines. Multiplexing approaches are therefore in development to provide cost-efficient solution. Construct-specific primers and probe were developed for quantitative analysis of Roundup Ready soybean (RRS) event glyphosate-tolerant soybean (GTS) 40-3-2. The lectin gene (Le1) was used as a reference gene, and its specificity was verified. RRS- and Le1-specific quantitative real-time PCR (qRTPCR) were optimized in a duplex platform that has been validated with respect to limit of detection (LOD) and limit of quantification (LOQ), as well as accuracy. The analysis of model processed food samples showed that the degradation of DNA has no adverse or little effects on the performance of quantification assay. In this study, a duplex qRTPCR using TaqMan minor groove binder-non-fluorescent quencher (MGB-NFQ) chemistry was developed for specific detection and quantification of RRS event GTS 40-3-2 that can be used for practical monitoring in processed food products.

  13. Determination of propineb and its metabolites propylenethiourea and propylenediamine in banana and soil using gas chromatography with flame photometric detection and LC-MS/MS analysis.

    PubMed

    Song, Shiming; Wei, Jie; Chen, Zhaojie; Lei, Yuhao; Zhang, Yan; Deng, Cheng; Tan, Huihua; Li, Xuesheng

    2018-03-04

    A sensitive and specific method for the determination of propineb and its metabolites, propylenethiourea (PTU) and propylenediamine (PDA), using gas chromatography with flame photometric detection (GC-FPD) and LC-MS/MS was developed and validated. Propineb and its metabolite residue dynamics in supervised field trials under Good Agricultural Practice (GAP) conditions in banana and soil were studied. Recovery of propineb (as CS 2 ), PDA and PTU ranged from 75.3 to 115.4% with RSD (n = 5) of 1.3-11.1%. The limit of quantification (LOQ) of CS 2 , PDA and PTU ranged from 0.005 to 0.01 mg kg -1 , and the limit of detection (LOD) ranged from 0.0015 to 0.0033 mg kg -1 . Dissipation experiments showed that the half-life of propineb in banana and soil ranged from 4.4 to 13.3 days. PTU was found in banana with a half-life of 31.5-69.3 days, while levels of PDA were less than 0.01 mg kg -1 in banana and soil. It has been suggested that PTU is the major metabolite of propineb in banana. The method was demonstrated to be reliable and sensitive for the routine monitoring of propineb and its metabolites in banana and soil. It also serves as a reference for the detection and monitoring of dithiocarbamates (DTCs) residues and the evaluation of their metabolic pathway.

  14. Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold Nanodendrites/Chitosan Nanoparticles.

    PubMed

    Sorouri, Rahim; Bagheri, Hasan; Afkhami, Abbas; Salimian, Jafar

    2017-05-09

    In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs) has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE) for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A). BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The charge transfer resistance (R CT ) changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN)₆ 3-/4- as a redox probe at pH = 7.4. A linear relationship was observed between the %∆ R CT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg·mL -1 with a detection limit (S/N = 3) of 0.15 pg·mL -1 . The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples.

  15. Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold Nanodendrites/Chitosan Nanoparticles

    PubMed Central

    Sorouri, Rahim; Bagheri, Hasan; Afkhami, Abbas; Salimian, Jafar

    2017-01-01

    In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs) has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE) for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A). BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The charge transfer resistance (RCT) changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN)63−/4− as a redox probe at pH = 7.4. A linear relationship was observed between the %∆RCT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg·mL−1 with a detection limit (S/N = 3) of 0.15 pg·mL−1. The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples. PMID:28486408

  16. 76 FR 29992 - Loan Policies and Operations; Lending and Leasing Limits and Risk Management

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-24

    ... System institutions by strengthening their risk mitigation practices and abilities to withstand volatile... leasing practices. In addition, one commenter recommended that there be consistent limits for titles I and... limit was not the best solution to address unsafe lending practices. Rather than lower the limit for...

  17. Novel images extraction model using improved delay vector variance feature extraction and multi-kernel neural network for EEG detection and prediction.

    PubMed

    Ge, Jing; Zhang, Guoping

    2015-01-01

    Advanced intelligent methodologies could help detect and predict diseases from the EEG signals in cases the manual analysis is inefficient available, for instance, the epileptic seizures detection and prediction. This is because the diversity and the evolution of the epileptic seizures make it very difficult in detecting and identifying the undergoing disease. Fortunately, the determinism and nonlinearity in a time series could characterize the state changes. Literature review indicates that the Delay Vector Variance (DVV) could examine the nonlinearity to gain insight into the EEG signals but very limited work has been done to address the quantitative DVV approach. Hence, the outcomes of the quantitative DVV should be evaluated to detect the epileptic seizures. To develop a new epileptic seizure detection method based on quantitative DVV. This new epileptic seizure detection method employed an improved delay vector variance (IDVV) to extract the nonlinearity value as a distinct feature. Then a multi-kernel functions strategy was proposed in the extreme learning machine (ELM) network to provide precise disease detection and prediction. The nonlinearity is more sensitive than the energy and entropy. 87.5% overall accuracy of recognition and 75.0% overall accuracy of forecasting were achieved. The proposed IDVV and multi-kernel ELM based method was feasible and effective for epileptic EEG detection. Hence, the newly proposed method has importance for practical applications.

  18. Aggregation, Validation, and Generalization of Qualitative Data - Methodological and Practical Research Strategies Illustrated by the Research Process of an empirically Based Typology.

    PubMed

    Weis, Daniel; Willems, Helmut

    2017-06-01

    The article deals with the question of how aggregated data which allow for generalizable insights can be generated from single-case based qualitative investigations. Thereby, two central challenges of qualitative social research are outlined: First, researchers must ensure that the single-case data can be aggregated and condensed so that new collective structures can be detected. Second, they must apply methods and practices to allow for the generalization of the results beyond the specific study. In the following, we demonstrate how and under what conditions these challenges can be addressed in research practice. To this end, the research process of the construction of an empirically based typology is described. A qualitative study, conducted within the framework of the Luxembourg Youth Report, is used to illustrate this process. Specifically, strategies are presented which increase the likelihood of generalizability or transferability of the results, while also highlighting their limitations.

  19. [Are non-invasive tests going to replace liver biopsy for diagnosis of liver fibrosis?].

    PubMed

    Restellini, Sophie; Spahr, Laurent

    2012-06-27

    Liver fibrosis is associated with chronic liver diseases, and may evolve into cirrhosis that may be complicated by liver failure and portal hypertension. Detection and quantification of liver fibrosis is a key point in the follow-up of patients with chronic liver diseases. Liver biopsy is the gold standard method to assess and quantify fibrosis, but its invasiveness is a limiting factor in everyday clinical practice. Non invasive markers using either biological or radiological parameters have been developed and may decrease the need for liver biopsy in some cases. However, information is limited to fibrosis, and cut-offs values and diagnostic accuracies for significant fibrosis may vary according to the etiology of liver disease. Liver biopsy allows the assessment of intermediate stages of fibrosis and describes accompanying lesions.

  20. Flexible Microsphere-Embedded Film for Microsphere-Enhanced Raman Spectroscopy.

    PubMed

    Xing, Cheng; Yan, Yinzhou; Feng, Chao; Xu, Jiayu; Dong, Peng; Guan, Wei; Zeng, Yong; Zhao, Yan; Jiang, Yijian

    2017-09-27

    Dielectric microspheres with extraordinary microscale optical properties, such as photonic nanojets, optical whispering-gallery modes (WGMs), and directional antennas, have drawn interest in many research fields. Microsphere-enhanced Raman spectroscopy (MERS) is an alternative approach for enhanced Raman detection by dielectric microstructures. Unfortunately, fabrication of microsphere monolayer arrays is the major challenge of MERS for practical applications on various specimen surfaces. Here we report a microsphere-embedded film (MF) by immersing a highly refractive microsphere monolayer array in the poly(dimethylsiloxane) (PDMS) film as a flexible MERS sensing platform for one- to three-dimensional (1D to 3D) specimen surfaces. The directional antennas and wave-guided whispering-gallery modes (WG-WGMs) contribute to the majority of Raman enhancement by the MFs. Moreover, the MF can be coupled with surface-enhanced Raman spectroscopy (SERS) to provide an extra >10-fold enhancement. The limit of detection is therefore improved for sensing of crystal violet (CV) and Sudan I molecules in aqueous solutions at concentrations down to 10 -7 M. A hybrid dual-layer microsphere enhancer, constructed by depositing a MF onto a microsphere monolayer array, is also demonstrated, wherein the WG-WGMs become dominant and boost the enhancement ratio >50-fold. The present work opens up new opportunities for design of cost-effective and flexible MERS sensing platforms as individual or associated techniques toward practical applications in ultrasensitive Raman detection.

  1. Electrochemical detection of C-reactive protein using Copper nanoparticles and hybridization chain reaction amplifying signal.

    PubMed

    Zhang, Junjun; Zhang, Wenjuan; Guo, Jinjin; Wang, Junchun; Zhang, Yuzhong

    2017-12-15

    In this study, a sandwich-type electrochemical immunosensor for the detection of C-reactive protein (CRP) is described. In design, Copper nanoparticles (Cu NPs) were used for signal tag and hybridization chain reaction (HCR)amplified output signal. The immunosensor fabrication involved three steps: (i) primary antibodies (Ab 1 ) were immobilized on the surface of gold nanoparticles (Au NPs); (ii) the sandwich-type structure formation contained "primary antibodies-antigen-secondary antibodies conjugated with primer (Ab 2 -S 0 )"; and (iii) long DNA concatemers intercalating amounts of Cu NPs was linked to the sandwich-type structure via hybridization reaction. Differential pulse voltammetry (DPV) was used to record the response signal of the immunosensor in phosphate-buffered saline (PBS). Under optimal conditions, the anodic peak currents of Cu NPs at the peak potential of about 0.08V(VS.SCE) were linear with the logarithm of CRP concentration in the range of 1.0 fg mL -1 to 100 ng mL -1 with a detection limit of 0.33 fg mL -1 (at signal/noise [S/N] = 3). In addition, the practical application of immunosensor was evaluated by analyzing CRP in real human serum samples, the recoveries obtained were within 95.3%-103.8%, indicating the immunosensor possessed potential application ability for practical disease diagnosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Cascade Signal Amplification Based on Copper Nanoparticle-Reported Rolling Circle Amplification for Ultrasensitive Electrochemical Detection of the Prostate Cancer Biomarker.

    PubMed

    Zhu, Ye; Wang, Huijuan; Wang, Lin; Zhu, Jing; Jiang, Wei

    2016-02-03

    An ultrasensitive and highly selective electrochemical assay was first attempted by combining the rolling circle amplification (RCA) reaction with poly(thymine)-templated copper nanoparticles (CuNPs) for cascade signal amplification. As proof of concept, prostate specific antigen (PSA) was selected as a model target. Using a gold nanoparticle (AuNP) as a carrier, we synthesized the primer-AuNP-aptamer bioconjugate for signal amplification by increasing the primer/aptamer ratio. The specific construction of primer-AuNP-aptamer/PSA/anti-PSA sandwich structure triggered the effective RCA reaction, in which thousands of tandem poly(thymine) repeats were generated and directly served as the specific templates for the subsequent CuNP formation. The signal readout was easily achieved by dissolving the RCA product-templated CuNPs and detecting the released copper ions with differential pulse stripping voltammetry. Because of the designed cascade signal amplification strategy, the newly developed method achieved a linear range of 0.05-500 fg/mL, with a remarkable detection limit of 0.020 ± 0.001 fg/mL PSA. Finally, the feasibility of the developed method for practical application was investigated by analyzing PSA in the real clinical human serum samples. The ultrasensitivity, specificity, convenience, and capability for analyzing the clinical samples demonstrate that this method has great potential for practical disease diagnosis applications.

  3. Rainwater harvesting in American Samoa: current practices and indicative health risks.

    PubMed

    Kirs, Marek; Moravcik, Philip; Gyawali, Pradip; Hamilton, Kerry; Kisand, Veljo; Gurr, Ian; Shuler, Christopher; Ahmed, Warish

    2017-05-01

    Roof-harvested rainwater (RHRW) is an important alternative source of water that many island communities can use for drinking and other domestic purposes when groundwater and/or surface water sources are contaminated, limited, or simply not available. The aim of this pilot-scale study was to investigate current RHRW practices in American Samoa (AS) and to evaluate and compare the quality of water from common potable water sources including RHRW stored in tanks, untreated stream water, untreated municipal well water, and treated municipal tap water samples. Samples were analyzed using culture-based methods, quantitative polymerase chain reaction (qPCR), and 16S amplicon sequencing-based methods. Based on indicator bacteria (total coliform and Escherichia coli) concentrations, the quality of RHRW was slightly lower than well and chlorinated tap water but exceeded that of untreated stream water. Although no Giardia or Leptospira spp. were detected in any of the RHRW samples, 86% of the samples were positive for Cryptosporidium spp. All stream water samples tested positive for Cryptosporidium spp. Opportunistic pathogens (Pseudomonas aeruginosa and Mycobacterium intracellulare) were also detected in the RHRW samples (71 and 21% positive samples, respectively). Several potentially pathogenic genera of bacteria were also detected in RHRW by amplicon sequencing. Each RHRW system was characterized by distinct microbial communities, 77% of operational taxonomic units (OTUs) were detected only in a single tank, and no OTU was shared by all the tanks. Risk of water-borne illness increased in the following order: chlorinated tap water/well water < RHRW < stream water. Frequent detection of opportunistic pathogens indicates that RHRW should be treated before use. Stakeholder education on RHRW system design options as well as on importance of regular cleaning and proper management techniques could improve the quality of the RHRW in AS.

  4. Evaluation of computer-aided detection and diagnosis systemsa)

    PubMed Central

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-01-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365

  5. A molecular rotor based ratiometric sensor for basic amino acids.

    PubMed

    Pettiwala, Aafrin M; Singh, Prabhat K

    2018-01-05

    The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.

    2015-12-01

    Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.

  7. Giant Gold Nanowire Vesicle-Based Colorimetric and SERS Dual-Mode Immunosensor for Ultrasensitive Detection of Vibrio parahemolyticus.

    PubMed

    Guo, Zhiyong; Jia, Yaru; Song, Xinxin; Lu, Jing; Lu, Xuefei; Liu, Baoqing; Han, Jiaojiao; Huang, Youju; Zhang, Jiawei; Chen, Tao

    2018-05-15

    Conventional methods for the detection of Vibrio parahemolyticus (VP) usually need tedious, labor-intensive processes, and have low sensitivity, which further limits their practical applications. Herein, we developed a simple and efficient colorimetry and surface-enhanced Raman scattering (SERS) dual-mode immunosensor for sensitive detection of VP, by employing giant Au vesicles with anchored tiny gold nanowires (AuNW) as a smart probe. Due to the larger specific surface and special hollow structure of giant Au vesicles, silver staining would easily lead to vivid color change for colorimetric analysis and further amplify SERS signals. The t-test was further used to determine if two sets of data from colorimetry and SERS were significantly different from each other. The result shows that there was no significant difference between data from the two methods. Two sets of data can mutually validate each other and avoid false positive and negative detection. The designed colorimetry-SERS dual-mode sensor would be very promising in various applications such as food safety inspection, personal healthcare, and on-site environmental monitoring.

  8. Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity

    PubMed Central

    Jensen, Kasper; Budvytyte, Rima; Thomas, Rodrigo A.; Wang, Tian; Fuchs, Annette M.; Balabas, Mikhail V.; Vasilakis, Georgios; Mosgaard, Lars D.; Stærkind, Hans C.; Müller, Jörg H.; Heimburg, Thomas; Olesen, Søren-Peter; Polzik, Eugene S.

    2016-01-01

    Magnetic fields generated by human and animal organs, such as the heart, brain and nervous system carry information useful for biological and medical purposes. These magnetic fields are most commonly detected using cryogenically-cooled superconducting magnetometers. Here we present the first detection of action potentials from an animal nerve using an optical atomic magnetometer. Using an optimal design we are able to achieve the sensitivity dominated by the quantum shot noise of light and quantum projection noise of atomic spins. Such sensitivity allows us to measure the nerve impulse with a miniature room-temperature sensor which is a critical advantage for biomedical applications. Positioning the sensor at a distance of a few millimeters from the nerve, corresponding to the distance between the skin and nerves in biological studies, we detect the magnetic field generated by an action potential of a frog sciatic nerve. From the magnetic field measurements we determine the activity of the nerve and the temporal shape of the nerve impulse. This work opens new ways towards implementing optical magnetometers as practical devices for medical diagnostics. PMID:27417378

  9. Preparation of highly stable fullerene C60 decorated graphene oxide nanocomposite and its sensitive electrochemical detection of dopamine in rat brain and pharmaceutical samples.

    PubMed

    Thirumalraj, Balamurugan; Palanisamy, Selvakumar; Chen, Shen-Ming; Lou, Bih-Show

    2016-01-15

    The research community has continuously paid much attention on the preparation of hybrid of carbon nanomaterials owing to combine their unique properties. Herein, we report the preparation of highly stable fullerene C60 (C60) wrapped graphene oxide (GO) nanocomposite by using a simple sonication method. The fabricated GO-C60 nanocomposite modified glassy carbon electrode shows a good sensitivity and lower oxidation overpotential towards dopamine (DA) than that of pristine GO and C60. The fabricated sensor detects the DA in the linear response range of 0.02-73.5μM. The limit of detection is estimated to be 0.008μM based on 3σ with a sensitivity of 4.23μAμM(-1)cm(-2). The fabricated sensor also exhibits other features such as good selectivity, stability, reproducibility and repeatability. The proposed sensor exhibits good practicality towards the detection of DA in rat brain and commercial DA injection samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Standoff detection of explosives and chemical agents using broadly tuned external-cavity quantum cascade lasers (EC-QCLs)

    NASA Astrophysics Data System (ADS)

    Takeuchi, Eric B.; Rayner, Timothy; Weida, Miles; Crivello, Salvatore; Day, Timothy

    2007-10-01

    Civilian soft targets such as transportation systems are being targeted by terrorists using IEDs and suicide bombers. Having the capability to remotely detect explosives, precursors and other chemicals would enable these assets to be protected with minimal interruption of the flow of commerce. Mid-IR laser technology offers the potential to detect explosives and other chemicals in real-time and from a safe standoff distance. While many of these agents possess "fingerprint" signatures in the mid-IR (i.e. in the 3-20 micron regime), their effective interrogation by a practical, field-deployable system has been limited by size, complexity, reliability and cost constraints of the base laser technology. Daylight Solutions has addressed these shortcomings by developing compact, portable, broadly tunable mid-IR laser sources based upon external-cavity quantum cascade technology. This technology is now being applied by Daylight in system level architectures for standoff and remote detection of explosives, precursors and chemical agents. Several of these architectures and predicted levels of performance will be presented.

  11. Multiplex real-time PCR assay for detection of pathogenic Vibrio parahaemolyticus strains.

    PubMed

    He, Peiyan; Chen, Zhongwen; Luo, Jianyong; Wang, Henghui; Yan, Yong; Chen, Lixia; Gao, Wenjie

    2014-01-01

    Foodborne disease caused by pathogenic Vibrio parahaemolyticus has become a serious public health problem in many countries. Rapid diagnosis and the identification of pathogenic V. parahaemolyticus are very important in the context of public health. In this study, an EvaGreen-based multiplex real-time PCR assay was established for the detection of pathogenic V. parahaemolyticus. This assay targeted three genetic markers of V. parahaemolyticus (species-specific gene toxR and virulence genes tdh and trh). The assay could unambiguously identify pathogenic V. parahaemolyticus with a minimum detection limit of 1.4 pg genomic DNA per reaction (concentration giving a positive multiplex real-time PCR result in 95% of samples). The specificity of the assay was evaluated using 72 strains of V. parahaemolyticus and other bacteria. A validation of the assay with clinical samples confirmed its sensitivity and specificity. Our data suggest the newly established multiplex real-time PCR assay is practical, cost-effective, specific, sensitive and capable of high-throughput detection of pathogenic V. parahaemolyticus. Copyright © 2014. Published by Elsevier Ltd.

  12. Development of sandwich ELISA for testing bovine β-lactoglobulin allergenic residues by specific polyclonal antibody against human IgE binding epitopes.

    PubMed

    He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing

    2017-07-15

    Bovine β-lactoglobulin (BLG) is the main allergen in cows' milk, and the most commonly used method for detecting BLG is enzyme-linked immunosorbent assay (ELISA). However, antibodies used in commercial ELISA kits do not recognize specifically BLG IgE epitopes. Here, an antibody specific to IgE linear epitopes for BLG was used to develop a sandwich ELISA using a rabbit anti-BLG polyclonal antibody. The linear range for BLG detection was 31.25-8000ng/mL and limit of detection was 1.96ng/mL. BLG content in dairy samples was determined, and there was a good agreement between this immunoassay and reversed-phase high-performance liquid chromatography with high recovery. Additionally, BLG content in food samples had an average recovery of 104.25%. Allergenic residues were also detected in hydrolyzed infant formulas. The method developed could be a practical approach to determine BLG and its allergenic residues in food with a high degree of sensitivity, reliability and recovery. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A proof of concept study to assess the potential of PCR testing to detect natural Mycobacterium bovis infection in South American camelids.

    PubMed

    Crawshaw, Timothy R; Chanter, Jeremy I; McGoldrick, Adrian; Line, Kirsty

    2014-02-07

    Cases of Mycobacterium bovis infection South American camelids have been increasing in Great Britain. Current antemortem immunological tests have some limitations. Cases at post mortem examination frequently show extensive pathology. The feasibility of detecting Mycobacterium bovis DNA in clinical samples was investigated. A sensitive extraction methodology was developed and used on nasal swabs and faeces taken post-mortem to assess the potential for a PCR test to detect Mycobacterium bovis in clinical samples. The gross pathology of the studied South American camelids was scored and a significantly greater proportion of South American camelids with more severe pathology were positive in both the nasal swab and faecal PCR tests. A combination of the nasal swab and faecal PCR tests detected 63.9% of all the South American camelids with pathology that were tested. The results suggest that antemortem diagnosis of Mycobacterium bovis in South American camelids may be possible using a PCR test on clinical samples, however more work is required to determine sensitivity and specificity, and the practicalities of applying the test in the field.

  14. Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity

    NASA Astrophysics Data System (ADS)

    Jensen, Kasper; Budvytyte, Rima; Thomas, Rodrigo A.; Wang, Tian; Fuchs, Annette M.; Balabas, Mikhail V.; Vasilakis, Georgios; Mosgaard, Lars D.; Stærkind, Hans C.; Müller, Jörg H.; Heimburg, Thomas; Olesen, Søren-Peter; Polzik, Eugene S.

    2016-07-01

    Magnetic fields generated by human and animal organs, such as the heart, brain and nervous system carry information useful for biological and medical purposes. These magnetic fields are most commonly detected using cryogenically-cooled superconducting magnetometers. Here we present the first detection of action potentials from an animal nerve using an optical atomic magnetometer. Using an optimal design we are able to achieve the sensitivity dominated by the quantum shot noise of light and quantum projection noise of atomic spins. Such sensitivity allows us to measure the nerve impulse with a miniature room-temperature sensor which is a critical advantage for biomedical applications. Positioning the sensor at a distance of a few millimeters from the nerve, corresponding to the distance between the skin and nerves in biological studies, we detect the magnetic field generated by an action potential of a frog sciatic nerve. From the magnetic field measurements we determine the activity of the nerve and the temporal shape of the nerve impulse. This work opens new ways towards implementing optical magnetometers as practical devices for medical diagnostics.

  15. Ion-exclusion/cation-exchange chromatography with dual detection of the conductivity and spectrophotometry for the simultaneous determination of common inorganic anionic species and cations in river and wastewater.

    PubMed

    Nakatani, Nobutake; Kozaki, Daisuke; Mori, Masanobu; Hasebe, Kiyoshi; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2011-01-01

    Simultaneous determinations of common inorganic anionic species (SO(4)(2-), Cl(-), NO(3)(-), phosphate and silicate) and cations (Na(+), NH(4)(+), K(+), Mg(2+) and Ca(2+)) were conducted using an ion-chromatography system with dual detection of conductivity and spectrophotometry in tandem. The separation of ionic species on a weakly acidic cation-exchange resin was accomplished using a mixture of 100 mM ascorbic acid and 4 mM 18-crown-6 as an acidic eluent (pH 2.6), after which the ions were detected using a conductivity detector. Subsequently, phosphate and silicate were analyzed based on derivatization with molybdate and spectrophotometry at 700 nm. The detection limits at S/N = 3 ranged from 0.11 to 2.9 µM for analyte ionic species. This method was applied to practical river water and wastewater with acceptable criteria for the anion-cation balance and comparisons of the measured and calculated electrical conductivity, demonstrating the usefulness of the present method for water quality monitoring.

  16. Nanofiber-net-binary structured membranes for highly sensitive detection of trace HCl gas

    NASA Astrophysics Data System (ADS)

    Wang, Xianfeng; Wang, Jialin; Si, Yang; Ding, Bin; Yu, Jianyong; Sun, Gang; Luo, Wenjing; Zheng, Gang

    2012-11-01

    This work describes the detection of trace hydrogen chloride (HCl) gas through analyses of the resonance frequency signal from quartz crystal microbalance (QCM) sensors coated with polyaniline (PANI) functionalized polyamide 6 (PA 6) (PANI-PA 6) nanofiber-net-binary (NNB) structured membranes. The PA 6 NNB substrate comprising nanofibers and spider-web-like nano-nets fabricated by a versatile electro-spinning/netting (ESN) process offered an ideal interface for the uniform PANI functionalization and enhanced sensing performance. Benefiting from the large specific surface area, high porosity, and strong adhesive force to the QCM electrode of the PANI-PA 6 NNB membranes, the developed HCl-selective sensors exhibited a rapid response, good reproducibility and stability, and low detection limit (7 ppb) at room temperature. Additionally, the PANI-PA 6 NNB sensing membranes presented visible color changes upon cycled exposure to HCl and ammonia, suggesting their potential application in the development of colorimetric sensors. The PANI-PA 6 NNB coated QCM sensors are considered to be a promising candidate for trace HCl gas detection in practical applications.

  17. Curcumin-cysteine and curcumin-tryptophan conjugate as fluorescence turn on sensors for picric Acid in aqueous media.

    PubMed

    Gogoi, Bedanta; Sen Sarma, Neelotpal

    2015-06-03

    Rapid detection of picric acid in real sample is of outmost importance from the perspective of health, safety, and environment. In this study, a very simple and cost-effective detection of picric acid is accomplished by developing a couple of biobased conjugates curcumin-cysteine (CC) and curcumin-tryptophan (CT), which undergo efficient fluorescence turn on toward picric acid in aqueous media. Both the probes experience about 26.5-fold fluorescence enhancements at 70 nM concentration of the analyte. Here, the fluorescence turn on process is governed by the aggregation induced emission, which is induced from the electrostatic interaction between the conjugates with picric acid. The detection limit of CC and CT are about 13.51 and 13.54 nM of picric acid, respectively. Importantly, both the probes exhibit high selectivity and low interference of other analogues toward the detection of picric acid. In addition, the probes are highly photostable, show low response time and are practically applicable for sensing picric acid in real environmental samples, which is the ultimate goal of this work.

  18. Precisely Determining Ultralow level UO22+ in Natural Water with Plasmonic Nanowire Interstice Sensor

    NASA Astrophysics Data System (ADS)

    Gwak, Raekeun; Kim, Hongki; Yoo, Seung Min; Lee, Sang Yup; Lee, Gyoung-Ja; Lee, Min-Ku; Rhee, Chang-Kyu; Kang, Taejoon; Kim, Bongsoo

    2016-01-01

    Uranium is an essential raw material in nuclear energy generation; however, its use raises concerns about the possibility of severe damage to human health and the natural environment. In this work, we report an ultrasensitive uranyl ion (UO22+) detection method in natural water that uses a plasmonic nanowire interstice (PNI) sensor combined with a DNAzyme-cleaved reaction. UO22+ induces the cleavage of DNAzymes into enzyme strands and released strands, which include Raman-active molecules. A PNI sensor can capture the released strands, providing strong surface-enhanced Raman scattering signal. The combination of a PNI sensor and a DNAzyme-cleaved reaction significantly improves the UO22+ detection performance, resulting in a detection limit of 1 pM and high selectivity. More importantly, the PNI sensor operates perfectly, even in UO22+-contaminated natural water samples. This suggests the potential usefulness of a PNI sensor in practical UO22+-sensing applications. We anticipate that diverse toxic metal ions can be detected by applying various ion-specific DNA-based ligands to PNI sensors.

  19. Ultrasensitive one-step rapid detection of ochratoxin A by the folding-based electrochemical aptasensor.

    PubMed

    Wu, Jingjing; Chu, Huaqin; Mei, Zhanlong; Deng, Yi; Xue, Feng; Zheng, Lei; Chen, Wei

    2012-11-13

    A one-step electrochemical aptasensor using the thiol- and methylene blue- (MB-) dual-labeled aptamer modified gold electrode for determination of ochratoxin A (OTA) was presented in this research. The aptamer against OTA was covalently immobilized on the surface of the electrode by the self-assembly effect and used as recognition probes for OTA detection by the binding induced folding of the aptamer. Under the optimal conditions, the developed electrochemical aptasensor demonstrated a wide linear range from 0.1 pg mL(-1) to 1000 pg mL(-1) with the limit of detection (LOD) of 0.095 pg mL(-1), which was an extraordinary sensitivity compared with other common methods for OTA detection. Moreover, as a practical application, this proposed electrochemical aptasensor was used to monitor the OTA level in red wine samples without any special pretreatment and with satisfactory results obtained. Study results showed that this electrochemical aptasensor could be a potential useful platform for on-site OTA measurement in real complex samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Urine specific gravity as an indicator of dehydration in Olympic combat sport athletes; considerations for research and practice.

    PubMed

    Zubac, Damir; Reale, Reid; Karnincic, Hrvoje; Sivric, Anamaria; Jelaska, Igor

    2018-05-10

    Urine specific gravity (U SG ) is the most commonly reported biochemical marker used in research and applied settings to detect fluid deficits in athletes, including those participating in combat sports. Despite the popularity of its use, there has been a growing debate regarding the diagnostic accuracy and the applicability of U SG in characterizing whole-body fluid status and fluctuations. Moreover, recent investigations report universally high prevalence of hypohydration (∼90%) via U SG assessment in combat sport athletes, often in spite of stable body-mass. Given the widespread use in both research and practice, and its use in a regulatory sense as a 'hydration test' in combat sports as a means to detect dehydration at the time of weigh-in; understanding the limitations and applicability of U SG assessment is of paramount importance. Inconsistencies in findings of U SG readings, possibly as a consequence of diverse methodological research approaches and/or overlooked confounding factors, preclude a conclusive position stand within current combat sports research and practice. Thus the primary aim of this paper is to critically review the literature regarding U SG assessment of hydration status in combat sports research and practice. When taken on balance, the existing literature suggests: the use of laboratory derived benchmarks in applied settings, inconsistent sampling methodologies, the incomplete picture of how various confounding factors affect end-point readings, and the still poorly understood potential of renal adaptation to dehydration in combat athletes; make the utility of hydration assessment via U SG measurement quite problematic, particularly when diet and training is not controlled.

  1. Associations between management practices and major reproductive parameters of Holstein-Friesian replacement heifers.

    PubMed

    Fodor, I; Baumgartner, W; Abonyi-Tóth, Zs; Lang, Zs; Ózsvári, L

    2018-01-01

    The aim of this study was to assess the relationship between the reproductive management practices and the performance of replacement heifers on large commercial dairy farms. The individual data of 14,763 heifers, first inseminated in 2014, were analysed from 33 Holstein-Friesian dairy herds in Hungary. The relationships between management practices and major reproductive parameters (age at first service, AFS; age at first calving, AFC; conception risk to first insemination, CR1; and pregnancy status at 20 months of age) were examined by mixed-effects models, with the herd as the random effect. The results showed that farms using oestrus detection aids experienced reduced AFS (p<0.001) and AFC (p=0.001). Observation of oestrus for shorter periods instead of continuously showed a tendency towards lower AFC (p=0.057) and was associated with higher odds of pregnancy at 20 months of age (p=0.020). Heifers on farms using sexed semen had younger AFS, but poorer CR1, compared to those using conventional semen exclusively (p<0.05). In addition, the odds of heifers being pregnant by 20 months of age was higher on farms with more experience using sexed semen (p=0.020). Frequent pregnancy diagnosis (i.e. more than once per week) was associated with younger AFC (p=0.023). Our results suggest the use of certain advanced reproductive management practices for heifer reproductive management in large dairy herds (e.g. oestrus detection aids), which can improve reproductive efficiency considerably, but are currently used only to a limited extent. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparative Effectiveness of Digital Versus Film-Screen Mammography in Community Practice in the United States

    PubMed Central

    Kerlikowske, Karla; Hubbard, Rebecca A.; Miglioretti, Diana L.; Geller, Berta M.; Yankaskas, Bonnie C.; Lehman, Constance D.; Taplin, Stephen H.; Sickles, Edward A.

    2013-01-01

    Background Few studies have examined the comparative effectiveness of digital versus film-screen mammography in U.S. community practice. Objective To determine whether the interpretive performance of digital and film-screen mammography differs. Design Prospective cohort study. Setting Mammography facilities in the Breast Cancer Surveillance Consortium. Participants 329 261 women aged 40 to 79 years underwent 869 286 mammograms (231 034 digital; 638 252 film-screen). Measurements Invasive cancer or ductal carcinoma in situ diagnosed within 12 months of a digital or film-screen examination and calculation of mammography sensitivity, specificity, cancer detection rates, and tumor outcomes. Results Overall, cancer detection rates and tumor characteristics were similar for digital and film-screen mammography, but the sensitivity and specificity of each modality varied by age, tumor characteristics, breast density, and menopausal status. Compared with film-screen mammography, the sensitivity of digital mammography was significantly higher for women aged 60 to 69 years (89.9% vs. 83.0%; P = 0.014) and those with estrogen receptor-negative cancer (78.5% vs. 65.8%; P = 0.016); borderline significantly higher for women aged 40 to 49 years (82.4% vs. 75.6%; P = 0.071), those with extremely dense breasts (83.6% vs. 68.1%; P= 0.051), and pre- or perimenopausal women (87.1% vs. 81.7%; P = 0.057); and borderline significantly lower for women aged 50 to 59 years (80.5% vs. 85.1%; P = 0.097). The specificity of digital and film-screen mammography was similar by decade of age, except for women aged 40 to 49 years (88.0% vs. 89.7%; P< 0.001). Limitation Statistical power for subgroup analyses was limited. Conclusion Overall, cancer detection with digital or film-screen mammography is similar in U.S. women aged 50 to 79 years undergoing screening mammography. Women aged 40 to 49 years are more likely to have extremely dense breasts and estrogen receptor-negative tumors; if they are offered mammography screening, they may choose to undergo digital mammography to optimize cancer detection. Primary Funding Source National Cancer Institute. PMID:22007043

  3. Screening versus routine practice in detection of atrial fibrillation in patients aged 65 or over: cluster randomised controlled trial

    PubMed Central

    Fitzmaurice, David A; Jowett, Sue; Mant, Jonathon; Murray, Ellen T; Holder, Roger; Raftery, J P; Bryan, S; Davies, Michael; Lip, Gregory Y H; Allan, T F

    2007-01-01

    Objectives To assess whether screening improves the detection of atrial fibrillation (cluster randomisation) and to compare systematic and opportunistic screening. Design Multicentred cluster randomised controlled trial, with subsidiary trial embedded within the intervention arm. Setting 50 primary care centres in England, with further individual randomisation of patients in the intervention practices. Participants 14 802 patients aged 65 or over in 25 intervention and 25 control practices. Interventions Patients in intervention practices were randomly allocated to systematic screening (invitation for electrocardiography) or opportunistic screening (pulse taking and invitation for electrocardiography if the pulse was irregular). Screening took place over 12 months in each practice from October 2001 to February 2003. No active screening took place in control practices. Main outcome measure Newly identified atrial fibrillation. Results The detection rate of new cases of atrial fibrillation was 1.63% a year in the intervention practices and 1.04% in control practices (difference 0.59%, 95% confidence interval 0.20% to 0.98%). Systematic and opportunistic screening detected similar numbers of new cases (1.62% v 1.64%, difference 0.02%, −0.5% to 0.5%). Conclusion Active screening for atrial fibrillation detects additional cases over current practice. The preferred method of screening in patients aged 65 or over in primary care is opportunistic pulse taking with follow-up electrocardiography. Trial registration Current Controlled Trials ISRCTN19633732. PMID:17673732

  4. Multisensor fusion for the detection of mines and minelike targets

    NASA Astrophysics Data System (ADS)

    Hanshaw, Terilee

    1995-06-01

    The US Army's Communications and Electronics Command through the auspices of its Night Vision and Electronics Sensors Directorate (CECOM-NVESD) is actively applying multisensor techniques to the detection of mine targets. This multisensor research results from the 'detection activity' with its broad range of operational conditions and targets. Multisensor operation justifies significant attention by yielding high target detection and low false alarm statistics. Furthermore, recent advances in sensor and computing technologies make its practical application realistic and affordable. The mine detection field-of-endeavor has since its WWI baptismal investigated the known spectra for applicable mine observation phenomena. Countless sensors, algorithms, processors, networks, and other techniques have been investigated to determine candidacy for mine detection. CECOM-NVESD efforts have addressed a wide range of sensors spanning the spectrum from gravity field perturbations, magentic field disturbances, seismic sounding, electromagnetic fields, earth penetrating radar imagery, and infrared/visible/ultraviolet surface imaging technologies. Supplementary analysis has considered sensor candidate applicability by testing under field conditions (versus laboratory), in determination of fieldability. As these field conditions directly effect the probability of detection and false alarms, sensor employment and design must be considered. Consequently, as a given sensor's performance is influenced directly by the operational conditions, tradeoffs are necessary. At present, mass produced and fielded mine detection techniques are limited to those incorporating a single sensor/processor methodology such as, pulse induction and megnetometry, as found in hand held detectors. The most sensitive fielded systems can detect minute metal components in small mine targets but result in very high false alarm rates reducing velocity in operation environments. Furthermore, the actual speed of advance for the entire mission (convoy, movement to engagement, etc.) is determined by the level of difficulty presented in clearance or avoidance activities required in response to the potential 'targets' marked throughout a detection activity. Therefore the application of fielded hand held systems to convoy operations in clearly impractical. CECOM-NVESD efforts are presently seeking to overcome these operational limitations by substantially increasing speed of detection while reducing the false alarm rate through the application of multisensor techniques. The CECOM-NVESD application of multisensor techniques through integration/fusion methods will be defined in this paper.

  5. Multiplex enrichment quantitative PCR (ME-qPCR): a high-throughput, highly sensitive detection method for GMO identification.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wei, Shuang; Zhixin, Du; Wang, Chenguang; Wu, Xiyang; Li, Feiwu; Zhu, Shuifang

    2017-04-01

    Among all of the high-throughput detection methods, PCR-based methodologies are regarded as the most cost-efficient and feasible methodologies compared with the next-generation sequencing or ChIP-based methods. However, the PCR-based methods can only achieve multiplex detection up to 15-plex due to limitations imposed by the multiplex primer interactions. The detection throughput cannot meet the demands of high-throughput detection, such as SNP or gene expression analysis. Therefore, in our study, we have developed a new high-throughput PCR-based detection method, multiplex enrichment quantitative PCR (ME-qPCR), which is a combination of qPCR and nested PCR. The GMO content detection results in our study showed that ME-qPCR could achieve high-throughput detection up to 26-plex. Compared to the original qPCR, the Ct values of ME-qPCR were lower for the same group, which showed that ME-qPCR sensitivity is higher than the original qPCR. The absolute limit of detection for ME-qPCR could achieve levels as low as a single copy of the plant genome. Moreover, the specificity results showed that no cross-amplification occurred for irrelevant GMO events. After evaluation of all of the parameters, a practical evaluation was performed with different foods. The more stable amplification results, compared to qPCR, showed that ME-qPCR was suitable for GMO detection in foods. In conclusion, ME-qPCR achieved sensitive, high-throughput GMO detection in complex substrates, such as crops or food samples. In the future, ME-qPCR-based GMO content identification may positively impact SNP analysis or multiplex gene expression of food or agricultural samples. Graphical abstract For the first-step amplification, four primers (A, B, C, and D) have been added into the reaction volume. In this manner, four kinds of amplicons have been generated. All of these four amplicons could be regarded as the target of second-step PCR. For the second-step amplification, three parallels have been taken for the final evaluation. After the second evaluation, the final amplification curves and melting curves have been achieved.

  6. Electromagnetic diagnostic techniques for hypervelocity projectile detection, velocity measurement, and size characterization: Theoretical concept and first experimental test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uhlig, W. Casey; Heine, Andreas, E-mail: andreas.heine@emi.fraunhofer.de

    2015-11-14

    A new measurement technique is suggested to augment the characterization and understanding of hypervelocity projectiles before impact. The electromagnetic technique utilizes magnetic diffusion principles to detect particles, measure velocity, and indicate relative particle dimensions. It is particularly suited for detection of small particles that may be difficult to track utilizing current characterization methods, such as high-speed video or flash radiography but can be readily used for large particle detection, where particle spacing or location is not practical for other measurement systems. In this work, particles down to 2 mm in diameter have been characterized while focusing on confining the detection signalmore » to enable multi-particle characterization with limited particle-to-particle spacing. The focus of the paper is on the theoretical concept and the analysis of its applicability based on analytical and numerical calculation. First proof-of-principle experimental tests serve to further validate the method. Some potential applications are the characterization of particles from a shaped-charge jet after its break-up and investigating debris in impact experiments to test theoretical models for the distribution of particles size, number, and velocity.« less

  7. Highly selective and sensitive coumarin-triazole-based fluorometric 'turn-off' sensor for detection of Pb2+ ions.

    PubMed

    Shaily; Kumar, Ajay; Parveen, Iram; Ahmed, Naseem

    2018-06-01

    Exposure to even very low concentrations of Pb 2+ is known to cause cardiovascular, neurological, developmental, and reproductive disorders, and affects children in particular more severely. Consequently, much effort has been dedicated to the development of colorimetric and fluorescent sensors that can selectively detect Pb 2+ ions. Here, we describe the development of a triazole-based fluorescent sensor L5 for Pb 2+ ion detection. The fluorescence intensity of chemosensor L5 was selectively quenched by Pb 2+ ions and a clear color change from colorless to yellow could be observed by the naked eye. Chemosensor L5 exhibited high sensitivity and selectivity towards Pb 2+ ions in phosphate-buffered solution [20 mM, 1:9 DMSO/H 2 O (v/v), pH 8.0] with a 1:1 binding stoichiometry, a detection limit of 1.9 nM and a 6.76 × 10 6  M -1 binding constant. Additionally, low-cost and easy-to-prepare test strips impregnated with chemosensor L5 were also produced for efficient of Pb 2+ detection and proved the practical use of this test. Copyright © 2018 John Wiley & Sons, Ltd.

  8. Efficient ensemble system based on the copper binding motif for highly sensitive and selective detection of cyanide ions in 100% aqueous solutions by fluorescent and colorimetric changes.

    PubMed

    Jung, Kwan Ho; Lee, Keun-Hyeung

    2015-09-15

    A peptide-based ensemble for the detection of cyanide ions in 100% aqueous solutions was designed on the basis of the copper binding motif. 7-Nitro-2,1,3-benzoxadiazole-labeled tripeptide (NBD-SSH, NBD-SerSerHis) formed the ensemble with Cu(2+), leading to a change in the color of the solution from yellow to orange and a complete decrease of fluorescence emission. The ensemble (NBD-SSH-Cu(2+)) sensitively and selectively detected a low concentration of cyanide ions in 100% aqueous solutions by a colorimetric change as well as a fluorescent change. The addition of cyanide ions instantly removed Cu(2+) from the ensemble (NBD-SSH-Cu(2+)) in 100% aqueous solutions, resulting in a color change of the solution from orange to yellow and a "turn-on" fluorescent response. The detection limits for cyanide ions were lower than the maximum allowable level of cyanide ions in drinking water set by the World Health Organization. The peptide-based ensemble system is expected to be a potential and practical way for the detection of submicromolar concentrations of cyanide ions in 100% aqueous solutions.

  9. Effects of Sampling and Spatio/Temporal Granularity in Traffic Monitoring on Anomaly Detectability

    NASA Astrophysics Data System (ADS)

    Ishibashi, Keisuke; Kawahara, Ryoichi; Mori, Tatsuya; Kondoh, Tsuyoshi; Asano, Shoichiro

    We quantitatively evaluate how sampling and spatio/temporal granularity in traffic monitoring affect the detectability of anomalous traffic. Those parameters also affect the monitoring burden, so network operators face a trade-off between the monitoring burden and detectability and need to know which are the optimal paramter values. We derive equations to calculate the false positive ratio and false negative ratio for given values of the sampling rate, granularity, statistics of normal traffic, and volume of anomalies to be detected. Specifically, assuming that the normal traffic has a Gaussian distribution, which is parameterized by its mean and standard deviation, we analyze how sampling and monitoring granularity change these distribution parameters. This analysis is based on observation of the backbone traffic, which exhibits spatially uncorrelated and temporally long-range dependence. Then we derive the equations for detectability. With those equations, we can answer the practical questions that arise in actual network operations: what sampling rate to set to find the given volume of anomaly, or, if the sampling is too high for actual operation, what granularity is optimal to find the anomaly for a given lower limit of sampling rate.

  10. Multi-Frequency Signal Detection Based on Frequency Exchange and Re-Scaling Stochastic Resonance and Its Application to Weak Fault Diagnosis

    PubMed Central

    Leng, Yonggang; Fan, Shengbo

    2018-01-01

    Mechanical fault diagnosis usually requires not only identification of the fault characteristic frequency, but also detection of its second and/or higher harmonics. However, it is difficult to detect a multi-frequency fault signal through the existing Stochastic Resonance (SR) methods, because the characteristic frequency of the fault signal as well as its second and higher harmonics frequencies tend to be large parameters. To solve the problem, this paper proposes a multi-frequency signal detection method based on Frequency Exchange and Re-scaling Stochastic Resonance (FERSR). In the method, frequency exchange is implemented using filtering technique and Single SideBand (SSB) modulation. This new method can overcome the limitation of "sampling ratio" which is the ratio of the sampling frequency to the frequency of target signal. It also ensures that the multi-frequency target signals can be processed to meet the small-parameter conditions. Simulation results demonstrate that the method shows good performance for detecting a multi-frequency signal with low sampling ratio. Two practical cases are employed to further validate the effectiveness and applicability of this method. PMID:29693577

  11. A comparison of infant and toddler feeding practices of mothers with and without histories of eating disorders

    PubMed Central

    Hoffman, Elizabeth R.; Bentley, Margaret E.; Hamer, Robert M.; Hodges, Eric A.; Ward, Dianne S.; Bulik, Cynthia M.

    2012-01-01

    This preliminary study surveyed the feeding practices of mothers with eating disorder histories through evaluation of mothers’ reported feeding styles, child diet composition, and restrictive special approaches to feeding. For this non-randomized cohort study, 25 mothers with eating disorder histories and 25 mothers with no history of an eating disorder with children ages 6–36 months were selected such that the groups were similar based on child age group and child sex. Mothers were compared on self-reported feeding style using the Infant Feeding Styles Questionnaire and on child diet composition and special feeding approaches using a modified version of the Toddler Diet Questionnaire from the Women, Infants, and Children program. Mothers with eating disorder histories scored lower on the restrictive feeding style subscale than controls. No significant differences were detected between groups in child diet including the percentage of mothers who breastfed, duration of breastfeeding, age at solid food introduction, daily number of meals or snacks, or daily frequency of consumption of fruits, vegetables, or protein foods. Mothers with eating disorder histories were more likely to report taking a restrictive special approach to feeding such as limiting processed foods or feeding organic foods only. Although mothers with eating disorder histories may not differ greatly from control mothers in terms of child diet composition (smaller effects may not have been detected due to limited sample size), they may be more likely to take restrictive special approaches to feeding which mirror dietary rules common in individuals with eating disorders. PMID:22784046

  12. Methods of analysis and quality-assurance practices of the U.S. Geological Survey organic laboratory, Sacramento, California; determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Crepeau, Kathryn L.; Domagalski, Joseph L.; Kuivila, Kathryn

    1994-01-01

    Analytical method and quality-assurance practices were developed for a study of the fate and transport of pesticides in the Sacramento-San Joaquin Delta and the Sacramento and San Joaquin River. Water samples were filtered to remove suspended parti- culate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide, and the pesticides were eluted with three 2-milliliter aliquots of hexane:diethyl ether (1:1). The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for analytes determined per 1,500-milliliter samples ranged from 0.006 to 0.047 microgram per liter. Recoveries ranged from 47 to 89 percent for 12 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.05 and 0.26 microgram per liter. The method was modified to improve the pesticide recovery by reducing the sample volume to 1,000 milliliters. Internal standards were added to improve quantitative precision and accuracy. The analysis also was expanded to include a total of 21 pesticides. The method detection limits for 1,000-milliliter samples ranged from 0.022 to 0.129 microgram per liter. Recoveries ranged from 38 to 128 percent for 21 pesticides in organic-free, Sacramento River and San Joaquin River water samples fortified at 0.10 and 0.75 microgram per liter.

  13. A comparison of infant and toddler feeding practices of mothers with and without histories of eating disorders.

    PubMed

    Hoffman, Elizabeth R; Bentley, Margaret E; Hamer, Robert M; Hodges, Eric A; Ward, Dianne S; Bulik, Cynthia M

    2014-07-01

    This preliminary study surveyed the feeding practices of mothers with eating disorder histories through evaluation of mothers' reported feeding styles, child diet composition and restrictive special approaches to feeding. For this non-randomised cohort study, 25 mothers with eating disorder histories and 25 mothers with no history of an eating disorder with children ages 6-36 months were selected such that the groups were similar based on child age group and child sex. Mothers were compared on self-reported feeding style using the Infant Feeding Styles Questionnaire and on child diet composition and special feeding approaches using a modified version of the Toddler Diet Questionnaire from the Women, Infants, and Children program. Mothers with eating disorder histories scored lower on the restrictive feeding style subscale than controls. No significant differences were detected between groups in child diet including the percentage of mothers who breastfed, duration of breastfeeding, age at solid food introduction, daily number of meals or snacks or daily frequency of consumption of fruits, vegetables or protein foods. Mothers with eating disorder histories were more likely to report taking a restrictive special approach to feeding such as limiting processed foods or feeding organic foods only. Although mothers with eating disorder histories may not differ greatly from control mothers in terms of child diet composition (smaller effects may not have been detected due to limited sample size), they may be more likely to take restrictive special approaches to feeding which mirror dietary rules common in individuals with eating disorders. © 2012 John Wiley & Sons Ltd.

  14. 40 CFR 63.9814 - What reports must I submit and when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... any emission limitations (emission limit, operating limit, or work practice standard) that apply to... limitations during the reporting period. (6) If there were no periods during which any affected CPMS was out... deviation from an emission limitation (emission limit, operating limit, or work practice standard) that...

  15. [Potential antimicrobial drug interactions in clinical practice: consequences of polypharmacy and multidrug resistance].

    PubMed

    Martínez-Múgica, Cristina

    2015-12-01

    Polypharmacy is a growing problem nowadays, which can increase the risk of potential drug interactions, and result in a loss of effectiveness. This is particularly relevant to the anti-infective therapy, especially when infection is produced by resistant bacteria, because therapeutic options are limited and interactions can cause treatment failure. All antimicrobial prescriptions were retrospectively reviewed during a week in the Pharmacy Department, in order to detect potential drug-interactions and analysing their clinical significance. A total of 314 antimicrobial prescriptions from 151 patients were checked. There was at least one potential interaction detected in 40% of patients, being more frequent and severe in those infected with multidrug-resistant microorganisms. Drugs most commonly involved were quinolones, azoles, linezolid and vancomycin. Potential drug interactions with antimicrobial agents are a frequent problem that can result in a loss of effectiveness. This is why they should be detected and avoided when possible, in order to optimize antimicrobial therapy, especially in case of multidrug resistant infections.

  16. Face recognition for criminal identification: An implementation of principal component analysis for face recognition

    NASA Astrophysics Data System (ADS)

    Abdullah, Nurul Azma; Saidi, Md. Jamri; Rahman, Nurul Hidayah Ab; Wen, Chuah Chai; Hamid, Isredza Rahmi A.

    2017-10-01

    In practice, identification of criminal in Malaysia is done through thumbprint identification. However, this type of identification is constrained as most of criminal nowadays getting cleverer not to leave their thumbprint on the scene. With the advent of security technology, cameras especially CCTV have been installed in many public and private areas to provide surveillance activities. The footage of the CCTV can be used to identify suspects on scene. However, because of limited software developed to automatically detect the similarity between photo in the footage and recorded photo of criminals, the law enforce thumbprint identification. In this paper, an automated facial recognition system for criminal database was proposed using known Principal Component Analysis approach. This system will be able to detect face and recognize face automatically. This will help the law enforcements to detect or recognize suspect of the case if no thumbprint present on the scene. The results show that about 80% of input photo can be matched with the template data.

  17. Indirect glyphosate detection based on ninhydrin reaction and surface-enhanced Raman scattering spectroscopy

    NASA Astrophysics Data System (ADS)

    Xu, Meng-Lei; Gao, Yu; Li, Yali; Li, Xueliang; Zhang, Huanjie; Han, Xiao Xia; Zhao, Bing; Su, Liang

    2018-05-01

    Glyphosate is one of the most commonly-used and non-selective herbicides in agriculture, which may directly pollute the environment and threaten human health. A simple and effective approach to assessment of its damage to the natural environment is thus quite necessary. However, traditional chromatography-based detection methods usually suffer from complex pretreatment procedures. Herein, we propose a simple and sensitive method for the determination of glyphosate by combining ninhydrin reaction and surface-enhanced Raman scattering (SERS) spectroscopy. The product (purple color dye, PD) of the ninhydrin reaction is found to SERS-active and directly correlate with the glyphosate concentration. The limit of detection of the proposed method for glyphosate is as low as 1.43 × 10- 8 mol·L- 1 with a relatively wider linear concentration range (1.0 × 10- 7-1.0 × 10- 4 mol·L- 1), which demonstrates its great potential in rapid, highly sensitive concentration determination of glyphosate in practical applications for safety assessment of food and environment.

  18. Crosswalk navigation for people with visual impairments on a wearable device

    NASA Astrophysics Data System (ADS)

    Cheng, Ruiqi; Wang, Kaiwei; Yang, Kailun; Long, Ningbo; Hu, Weijian; Chen, Hao; Bai, Jian; Liu, Dong

    2017-09-01

    Detecting and reminding of crosswalks at urban intersections is one of the most important demands for people with visual impairments. A real-time crosswalk detection algorithm, adaptive extraction and consistency analysis (AECA), is proposed. Compared with existing algorithms, which detect crosswalks in ideal scenarios, the AECA algorithm performs better in challenging scenarios, such as crosswalks at far distances, low-contrast crosswalks, pedestrian occlusion, various illuminances, and the limited resources of portable PCs. Bright stripes of crosswalks are extracted by adaptive thresholding, and are gathered to form crosswalks by consistency analysis. On the testing dataset, the proposed algorithm achieves a precision of 84.6% and a recall of 60.1%, which are higher than the bipolarity-based algorithm. The position and orientation of crosswalks are conveyed to users by voice prompts so as to align themselves with crosswalks and walk along crosswalks. The field tests carried out in various practical scenarios prove the effectiveness and reliability of the proposed navigation approach.

  19. Detecting Vessels Carrying Migrants Using Machine Learning

    NASA Astrophysics Data System (ADS)

    Sfyridis, A.; Cheng, T.; Vespe, M.

    2017-10-01

    Political instability, conflicts and inequalities result into significant flows of people worldwide, moving to different countries in search of a better life, safety or to be reunited with their families. Irregular crossings into Europe via sea routes, despite not being new, have recently increased together with the loss of lives of people in the attempt to reach EU shores. This highlights the need to find ways to improve the understanding of what is happening at sea. This paper, intends to expand the knowledge available on practices among smugglers and contribute to early warning and maritime situational awareness. By identifying smuggling techniques and based on anomaly detection methods, behaviours of interest are modelled and one class support vector machines are used to classify unlabelled data and detect potential smuggling vessels. Nine vessels are identified as potentially carrying irregular migrants and refugees. Though, further inspection of the results highlights possible misclassifications caused by data gaps and limited knowledge on smuggling tactics. Accepted classifications are considered subject to further investigation by the authorities.

  20. Enhanced light extraction of plastic scintillator using large-area photonic crystal structures fabricated by hot embossing.

    PubMed

    Chen, Xueye; Liu, Bo; Wu, Qiang; Zhu, Zhichao; Zhu, Jingtao; Gu, Mu; Chen, Hong; Liu, Jinliang; Chen, Liang; Ouyang, Xiaoping

    2018-04-30

    Plastic scintillators are widely used in various radiation measurement systems. However, detection efficiency and signal-to-noise are limited due to the total internal reflection, especially for weak signal detection situations. In the present investigation, large-area photonic crystals consisting of an array of periodic truncated cone holes were prepared based on hot embossing technology aiming at coupling with the surface of plastic scintillator to improve the light extraction efficiency and directionality control. The experimental results show that a maximum enhancement of 64% at 25° emergence angle along Γ-M orientation and a maximum enhancement of 58% at 20° emergence angle along Γ-K orientation were obtained. The proposed fabrication method of photonic crystal scintillator can avoid complicated pattern transfer processes used in most traditional methods, leading to a simple, economical method for large-area preparation. The photonic crystal scintillator demonstrated in this work is of great value for practical applications of nuclear radiation detection.

  1. Sensitive Nonenzymatic Electrochemical Glucose Detection Based on Hollow Porous NiO

    NASA Astrophysics Data System (ADS)

    He, Gege; Tian, Liangliang; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Pu, Wanrong; Zhang, Jinkun; Li, Lu

    2018-01-01

    Transition metal oxides (TMOs) have attracted extensive research attentions as promising electrocatalytic materials. Despite low cost and high stability, the electrocatalytic activity of TMOs still cannot satisfy the requirements of applications. Inspired by kinetics, the design of hollow porous structure is considered as a promising strategy to achieve superior electrocatalytic performance. In this work, cubic NiO hollow porous architecture (NiO HPA) was constructed through coordinating etching and precipitating (CEP) principle followed by post calcination. Being employed to detect glucose, NiO HPA electrode exhibits outstanding electrocatalytic activity in terms of high sensitivity (1323 μA mM-1 cm-2) and low detection limit (0.32 μM). The excellent electrocatalytic activity can be ascribed to large specific surface area (SSA), ordered diffusion channels, and accelerated electron transfer rate derived from the unique hollow porous features. The results demonstrate that the NiO HPA could have practical applications in the design of nonenzymatic glucose sensors. The construction of hollow porous architecture provides an effective nanoengineering strategy for high-performance electrocatalysts.

  2. SERS Detection of Biomolecules by Highly Sensitive and Reproducible Raman-Enhancing Nanoparticle Array

    NASA Astrophysics Data System (ADS)

    Chan, Tzu-Yi; Liu, Ting-Yu; Wang, Kuan-Syun; Tsai, Kun-Tong; Chen, Zhi-Xin; Chang, Yu-Chi; Tseng, Yi-Qun; Wang, Chih-Hao; Wang, Juen-Kai; Wang, Yuh-Lin

    2017-05-01

    This paper describes the preparation of nanoarrays composed of silver nanoparticles (AgNPs: 20-50 nm) for use as surface-enhanced Raman scattering (SERS) substrates. The AgNPs were grown on porous anodic aluminum oxide (AAO) templates by electrochemical plating, and the inter-channel gap of AAO channels is between 10 and 20 nm. The size and interparticle gap of silver particles were adjusted in order to achieve optimal SERS signals and characterized by scanning electron microscopy, atomic force microscopy, and Raman spectroscopy. The fluctuation of SERS intensity is about 10-20% when measuring adenine solutions, showing a great reproducible SERS sensing. The nanoparticle arrays offer a large potential for practical applications as shown by the SERS-based quantitative detection and differentiation of adenine (A), thymine (T), cytosine (C), guanine (G), β-carotene, and malachite green. The respective detection limits are <1 ppb for adenine and <0.63 ppm for β-carotene and malachite green, respectively.

  3. Environmental 90Sr measurements

    USGS Publications Warehouse

    Paul, M.; Berkovits, D.; Cecil, L.D.; Feldstein, H.; Hershkowitz, A.; Kashiv, Y.; Vogt, S.

    1997-01-01

    90Sr (T1/2 = 28.5 years) is a long-lived radionuclide produced in nuclear fission. Fast radiochemical detection of 90Sr in environmental samples is not feasible using current analytical methods. Accelerator Mass Spectrometry (AMS) measurements of 90Sr were made with the Rehovot 14UD Pelletron accelerator at a terminal voltage of 11 or 12 MV using our standard detection system. Injection of hydride ions (SrH3-) was chosen owing to high beam intensity and low Coulomb explosion effects. 90Sr ions were identified and discriminated from isobaric 90Zr by measuring time of flight, total energy and three independent energy-loss signals in an ionization chamber. A reference sample and a ground-water sample were successfully measured. The detection limit determined for a laboratory blank by the residual counts in the 90Sr region is 90Sr/Sr = 3 ?? 10-13, corresponding in practice to (2-4) ?? 10790Sr atoms or about 0.5-1 pCi/L in environmental water samples.

  4. Simulation study and guidelines to generate Laser-induced Surface Acoustic Waves for human skin feature detection

    NASA Astrophysics Data System (ADS)

    Li, Tingting; Fu, Xing; Chen, Kun; Dorantes-Gonzalez, Dante J.; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2015-12-01

    Despite the seriously increasing number of people contracting skin cancer every year, limited attention has been given to the investigation of human skin tissues. To this regard, Laser-induced Surface Acoustic Wave (LSAW) technology, with its accurate, non-invasive and rapid testing characteristics, has recently shown promising results in biological and biomedical tissues. In order to improve the measurement accuracy and efficiency of detecting important features in highly opaque and soft surfaces such as human skin, this paper identifies the most important parameters of a pulse laser source, as well as provides practical guidelines to recommended proper ranges to generate Surface Acoustic Waves (SAWs) for characterization purposes. Considering that melanoma is a serious type of skin cancer, we conducted a finite element simulation-based research on the generation and propagation of surface waves in human skin containing a melanoma-like feature, determine best pulse laser parameter ranges of variation, simulation mesh size and time step, working bandwidth, and minimal size of detectable melanoma.

  5. Single photon detection and timing in the Lunar Laser Ranging Experiment.

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.

    1972-01-01

    The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

  6. Electrochemical Sensing toward Trace As(III) Based on Mesoporous MnFe₂O₄/Au Hybrid Nanospheres Modified Glass Carbon Electrode.

    PubMed

    Zhou, Shaofeng; Han, Xiaojuan; Fan, Honglei; Liu, Yaqing

    2016-06-22

    Au nanoparticles decorated mesoporous MnFe₂O₄ nanocrystal clusters (MnFe₂O₄/Au hybrid nanospheres) were used for the electrochemical sensing of As(III) by square wave anodic stripping voltammetry (SWASV). Modified on a cheap glass carbon electrode, these MnFe₂O₄/Au hybrid nanospheres show favorable sensitivity (0.315 μA/ppb) and limit of detection (LOD) (3.37 ppb) toward As(III) under the optimized conditions in 0.1 M NaAc-HAc (pH 5.0) by depositing for 150 s at the deposition potential of -0.9 V. No obvious interference from Cd(II) and Hg(II) was recognized during the detection of As(III). Additionally, the developed electrode displayed good reproducibility, stability, and repeatability, and offered potential practical applicability for electrochemical detection of As(III) in real water samples. The present work provides a potential method for the design of new and cheap sensors in the application of electrochemical determination toward trace As(III) and other toxic metal ions.

  7. Nonimaging aspects of follow-up in breast cancer reconstruction.

    PubMed

    Wood, W C

    1991-09-01

    Follow-up of patients with breast cancer is directed to the early detection of recurrent or metastatic disease and the detection of new primary breast cancer. The survival benefit of early detection is limited to some patients with local failure or new primary tumors. That imaging is not used in follow-up of patients who have had breast cancer reconstruction is related to possible interference with this putative benefit by the reconstructive procedure. Such follow-up is accomplished by the patient's own surveillance, clinical examination, and laboratory testing supplemented by imaging studies. Clinical follow-up trials of women who have undergone breast reconstructive surgery show no evidence that locally recurrent breast carcinoma is masked when compared with follow-up of women who did not undergo reconstructive procedures. Reshaping of the contralateral breast to match the reconstructed breast introduces the possibility of interference with palpation as well as mammographic distortion in some women. This is an uncommon practical problem except when complicated by fat necrosis.

  8. Karst topography : noninvasive geophysical detection methods and construction techniques.

    DOT National Transportation Integrated Search

    2013-10-01

    The objective of this project was to investigate the current state of the practice with regards to karst detection : methods and current karst construction practices and to recommend the best practices for use by the Virginia : Department of Transpor...

  9. Maternal controlling feeding practices and girls’ inhibitory control interact to predict changes in BMI and eating in the absence of hunger from 5 to 7 y1234

    PubMed Central

    Rollins, Brandi Y; Loken, Eric; Savage, Jennifer S; Birch, Leann L

    2014-01-01

    Background: Mothers use a range of feeding practices to limit children's intake of palatable snacks (eg, keeping snacks out of reach, not bringing snacks into the home), but less is known about the effects of these practices on children's eating and weight outcomes. Objective: The objective was to identify distinct feeding practice profiles and evaluate the interactive effects of these profiles and girls’ temperament (inhibitory control and approach) on girls’ eating behaviors and weight outcomes at 5 and 7 y. Design: Participants included 180 mother-daughter dyads; measures were mothers’ reports of controlling feeding practices and girls’ height and weight, eating in the absence of hunger (EAH) at 5 y, and inhibitory control (a measure of behavioral inhibition) and approach (a measure of appetitive motivation) at 7 y. Results: Latent profile analysis of maternal feeding practices showed 4 feeding profiles based on maternal use of limit-setting practices and keeping snacks out of girls’ physical reach, a restrictive practice: Unlimited Access to Snacks, Sets Limits+Does Not Restrict Snacks, Sets Limits+Restricts High Fat/Sugar Snacks, and Sets Limits+Restricts All Snacks. Girls whose mothers used Sets Limits+Restricts All Snacks had a higher approach and EAH at 5 y. Low inhibitory control girls whose mothers used Sets Limits+Restricts All Snacks or Unlimited Access to Snacks had greater increases in EAH and body mass index (BMI) from 5 to 7 y. Conclusions: Effects of maternal control on girls’ EAH and BMI may differ by the type of practice used (eg, limit-setting or restrictive practices). Girls with low inhibitory control were more susceptible to the negative effects of low and high control. PMID:24284443

  10. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging

    NASA Astrophysics Data System (ADS)

    Rose, P. B.; Erickson, A. S.; Mayer, M.; Nattress, J.; Jovanovic, I.

    2016-04-01

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as “searching for a needle in a haystack” because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method from being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material’s areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.

  11. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Jr., P. B.; Erickson, A. S.; Mayer, Michael F.

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as “searching for a needle in a haystack” because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method frommore » being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material’s areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.« less

  12. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging

    DOE PAGES

    Rose, P. B.; Erickson, A. S.; Mayer, M.; ...

    2016-04-18

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as “searching for a needle in a haystack” because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method frommore » being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material’s areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.« less

  13. Spectral Transfer Learning Using Information Geometry for a User-Independent Brain-Computer Interface

    PubMed Central

    Waytowich, Nicholas R.; Lawhern, Vernon J.; Bohannon, Addison W.; Ball, Kenneth R.; Lance, Brent J.

    2016-01-01

    Recent advances in signal processing and machine learning techniques have enabled the application of Brain-Computer Interface (BCI) technologies to fields such as medicine, industry, and recreation; however, BCIs still suffer from the requirement of frequent calibration sessions due to the intra- and inter-individual variability of brain-signals, which makes calibration suppression through transfer learning an area of increasing interest for the development of practical BCI systems. In this paper, we present an unsupervised transfer method (spectral transfer using information geometry, STIG), which ranks and combines unlabeled predictions from an ensemble of information geometry classifiers built on data from individual training subjects. The STIG method is validated in both off-line and real-time feedback analysis during a rapid serial visual presentation task (RSVP). For detection of single-trial, event-related potentials (ERPs), the proposed method can significantly outperform existing calibration-free techniques as well as outperform traditional within-subject calibration techniques when limited data is available. This method demonstrates that unsupervised transfer learning for single-trial detection in ERP-based BCIs can be achieved without the requirement of costly training data, representing a step-forward in the overall goal of achieving a practical user-independent BCI system. PMID:27713685

  14. Spectral Transfer Learning Using Information Geometry for a User-Independent Brain-Computer Interface.

    PubMed

    Waytowich, Nicholas R; Lawhern, Vernon J; Bohannon, Addison W; Ball, Kenneth R; Lance, Brent J

    2016-01-01

    Recent advances in signal processing and machine learning techniques have enabled the application of Brain-Computer Interface (BCI) technologies to fields such as medicine, industry, and recreation; however, BCIs still suffer from the requirement of frequent calibration sessions due to the intra- and inter-individual variability of brain-signals, which makes calibration suppression through transfer learning an area of increasing interest for the development of practical BCI systems. In this paper, we present an unsupervised transfer method (spectral transfer using information geometry, STIG), which ranks and combines unlabeled predictions from an ensemble of information geometry classifiers built on data from individual training subjects. The STIG method is validated in both off-line and real-time feedback analysis during a rapid serial visual presentation task (RSVP). For detection of single-trial, event-related potentials (ERPs), the proposed method can significantly outperform existing calibration-free techniques as well as outperform traditional within-subject calibration techniques when limited data is available. This method demonstrates that unsupervised transfer learning for single-trial detection in ERP-based BCIs can be achieved without the requirement of costly training data, representing a step-forward in the overall goal of achieving a practical user-independent BCI system.

  15. eHealth in cardiovascular medicine: A clinical update.

    PubMed

    Saner, Hugo; van der Velde, Enno

    2016-10-01

    Demographic changes, progress in medicine technology and regional problems in providing healthcare to low density populations are posing great challenges to our healthcare systems. Rapid progress in computer sciences and information technologies have a great impact on the way healthcare will be delivered in the near future. This article describes opportunities and challenges of eHealth and telemedicine in the framework of our health systems and, in particular, in the context of today's cardiology services. The most promising applications of eHealth and telemedicine include: (a) prevention and lifestyle interventions; (b) chronic disease management including hypertension, diabetes and heart failure; (c) arrhythmia detection including early detection of atrial fibrillation and telemonitoring of devices such as pacemaker, internal cardioverter defibrillators and implantable rhythm monitoring devices; (d) telerehabilitation. Major obstacles to the integration of eHealth and telemedicine into daily clinical practice include limited large-scale evidence, in particular, for cost-effectiveness, as well as lack of interoperability, inadequate or fragmented legal frameworks and lack of reimbursement. An important challenge for those involved in these new technologies will be to keep the main focus on patient's individual needs and to carefully evaluate the evidence behind the practice. © The European Society of Cardiology 2016.

  16. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging

    PubMed Central

    Rose, P. B.; Erickson, A. S.; Mayer, M.; Nattress, J.; Jovanovic, I.

    2016-01-01

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as “searching for a needle in a haystack” because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method from being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material’s areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications. PMID:27087555

  17. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging.

    PubMed

    Rose, P B; Erickson, A S; Mayer, M; Nattress, J; Jovanovic, I

    2016-04-18

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as "searching for a needle in a haystack" because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method from being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material's areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.

  18. A comparison of DNA extraction protocols from blood spotted on FTA cards for the detection of tick-borne pathogens by Reverse Line Blot hybridization.

    PubMed

    Hailemariam, Zerihun; Ahmed, Jabbar Sabir; Clausen, Peter-Henning; Nijhof, Ard Menzo

    2017-01-01

    An essential step in the molecular detection of tick-borne pathogens (TBPs) in blood is the extraction of DNA. When cooled storage of blood under field conditions prior to DNA extraction in a dedicated laboratory is not possible, the storage of blood on filter paper forms a promising alternative. We evaluated six DNA extraction methods from blood spotted on FTA Classic ® cards (FTA cards), to determine the optimal protocol for the subsequent molecular detection of TBPs by PCR and the Reverse Line Blot hybridization assay (RLB). Ten-fold serial dilutions of bovine blood infected with Babesia bovis, Theileria mutans, Anaplasma marginale or Ehrlichia ruminantium were made by dilution with uninfected blood and spotted on FTA cards. Subsequently, DNA was extracted from FTA cards using six different DNA extraction protocols. DNA was also isolated from whole blood dilutions using a commercial kit. PCR/RLB results showed that washing of 3mm discs punched from FTA cards with FTA purification reagent followed by DNA extraction using Chelex ® resin was the most sensitive procedure. The detection limit could be improved when more discs were used as starting material for the DNA extraction, whereby the use of sixteen 3mm discs proved to be most practical. The presented best practice method for the extraction of DNA from blood spotted on FTA cards will facilitate epidemiological studies on TBPs. It may be particularly useful for field studies where a cold chain is absent. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. The relationship between organizational policies and practices and work limitations among hospital patient care workers.

    PubMed

    Sparer, Emily H; Boden, Leslie I; Sorensen, Glorian; Dennerlein, Jack T; Stoddard, Anne; Wagner, Gregory R; Nagler, Eve M; Hashimoto, Dean M; Hopcia, Karen; Sabbath, Erika L

    2018-05-29

    We examined relationships between organizational policies and practices (OPPs) (safety practices, ergonomic practices, and people-oriented culture) and work limitations in a sample of hospital workers. We used the 6-item Work Limitations Questionnaire (WLQ) to assess workers' perceptions of health-related work limitations. Self-reported OPPs and the WLQ were collected from workers in Boston, Massachusetts (n = 1277). We conducted random-intercept multi-level logistic regression models for each OPP using stepwise selection of covariates. As the unit-average ergonomic practice score increased by one, the odds of a worker reporting work limitations decreased by approximately 39% (P-value = 0.018), adjusted for job title, age, and body mass index. A similar relationship existed for people-oriented culture (P-value = 0.038). The association between safety practices and work limitations was similar, but not statistically significant. This study demonstrated the importance of workplace OPPs. OPPs that promote positive and supportive environments and that foster improvements in ergonomics may help reduce work limitations. © 2018 Wiley Periodicals, Inc.

  20. Development of E-Learning Materials for Machining Safety Education

    NASA Astrophysics Data System (ADS)

    Nakazawa, Tsuyoshi; Mita, Sumiyoshi; Matsubara, Masaaki; Takashima, Takeo; Tanaka, Koichi; Izawa, Satoru; Kawamura, Takashi

    We developed two e-learning materials for Manufacturing Practice safety education: movie learning materials and hazard-detection learning materials. Using these video and sound media, students can learn how to operate machines safely with movie learning materials, which raise the effectiveness of preparation and review for manufacturing practice. Using these materials, students can realize safety operation well. Students can apply knowledge learned in lectures to the detection of hazards and use study methods for hazard detection during machine operation using the hazard-detection learning materials. Particularly, the hazard-detection learning materials raise students‧ safety consciousness and increase students‧ comprehension of knowledge from lectures and comprehension of operations during Manufacturing Practice.

  1. Biomolecule detection based on Si single-electron transistors for practical use

    NASA Astrophysics Data System (ADS)

    Nakajima, Anri; Kudo, Takashi; Furuse, Sadaharu

    2013-07-01

    Experimental and theoretical analyses demonstrated that ultra-sensitive biomolecule detection can be achieved using a Si single-electron transistor (SET). A multi-island channel structure was used to enable room-temperature operation. Coulomb oscillation increases transconductance without increasing channel width, which increases detection sensitivity to a charged target. A biotin-modified SET biosensor was used to detect streptavidin at a dilute concentration. In addition, an antibody-functionalized SET biosensor was used for immunodetection of prostate-specific antigen, demonstrating its suitability for practical use. The feasibility of ultra-sensitive detection of biomolecules for practical use by using a SET biosensor was clearly proven through this systematic study.

  2. Microbial Fuels Cell-Based Biosensor for Toxicity Detection: A Review

    PubMed Central

    Zhou, Tuoyu; Han, Huawen; Liu, Pu; Xiong, Jian; Tian, Fake; Li, Xiangkai

    2017-01-01

    With the unprecedented deterioration of environmental quality, rapid recognition of toxic compounds is paramount for performing in situ real-time monitoring. Although several analytical techniques based on electrochemistry or biosensors have been developed for the detection of toxic compounds, most of them are time-consuming, inaccurate, or cumbersome for practical applications. More recently, microbial fuel cell (MFC)-based biosensors have drawn increasing interest due to their sustainability and cost-effectiveness, with applications ranging from the monitoring of anaerobic digestion process parameters (VFA) to water quality detection (e.g., COD, BOD). When a MFC runs under correct conditions, the voltage generated is correlated with the amount of a given substrate. Based on this linear relationship, several studies have demonstrated that MFC-based biosensors could detect heavy metals such as copper, chromium, or zinc, as well as organic compounds, including p-nitrophenol (PNP), formaldehyde and levofloxacin. Both bacterial consortia and single strains can be used to develop MFC-based biosensors. Biosensors with single strains show several advantages over systems integrating bacterial consortia, such as selectivity and stability. One of the limitations of such sensors is that the detection range usually exceeds the actual pollution level. Therefore, improving their sensitivity is the most important for widespread application. Nonetheless, MFC-based biosensors represent a promising approach towards single pollutant detection. PMID:28956857

  3. Microbial Fuels Cell-Based Biosensor for Toxicity Detection: A Review.

    PubMed

    Zhou, Tuoyu; Han, Huawen; Liu, Pu; Xiong, Jian; Tian, Fake; Li, Xiangkai

    2017-09-28

    With the unprecedented deterioration of environmental quality, rapid recognition of toxic compounds is paramount for performing in situ real-time monitoring. Although several analytical techniques based on electrochemistry or biosensors have been developed for the detection of toxic compounds, most of them are time-consuming, inaccurate, or cumbersome for practical applications. More recently, microbial fuel cell (MFC)-based biosensors have drawn increasing interest due to their sustainability and cost-effectiveness, with applications ranging from the monitoring of anaerobic digestion process parameters (VFA) to water quality detection (e.g., COD, BOD). When a MFC runs under correct conditions, the voltage generated is correlated with the amount of a given substrate. Based on this linear relationship, several studies have demonstrated that MFC-based biosensors could detect heavy metals such as copper, chromium, or zinc, as well as organic compounds, including p -nitrophenol (PNP), formaldehyde and levofloxacin. Both bacterial consortia and single strains can be used to develop MFC-based biosensors. Biosensors with single strains show several advantages over systems integrating bacterial consortia, such as selectivity and stability. One of the limitations of such sensors is that the detection range usually exceeds the actual pollution level. Therefore, improving their sensitivity is the most important for widespread application. Nonetheless, MFC-based biosensors represent a promising approach towards single pollutant detection.

  4. Non-aggregation based label free colorimetric sensor for the detection of Cu2+ based on catalyzing etching of gold nanorods by dissolve oxygen.

    PubMed

    Liu, Jia-Ming; Jiao, Li; Lin, Li-Ping; Cui, Ma-Lin; Wang, Xin-Xing; Zhang, Li-Hong; Zheng, Zhi-Yong; Jiang, Shu-Lian

    2013-12-15

    A label-free non-aggregation colorimetric sensor has been designed for the detection of Cu(2+), based on Cu(2+) catalyzing etching of gold nanorods (AuNRs) along longitudinal axis induced by dissolve oxygen in the presence of S2O3(2-), which caused the aspect ratio (length/width) of AuNRs to decrease and the color of the solution to distinctly change. The linear range and the detection limit (LD, calculated by 10 Sb/k, n=11) of this sensor were 0.080-4.8 µM Cu(2+) and 0.22 µM Cu(2+), respectively. This sensor has been utilized to detect Cu(2+) in tap water and human serum samples with the results agreeing well with those of inductively coupled plasma-mass spectroscopy (ICP-MS), showing its remarkable practicality. In order to prove the possibility of catalyzing AuNRs non-aggregation colorimetric sensor for the detection of Cu(2+), the morphological structures of AuNRs were characterized by high resolution transmission electron microscopy (HRTEM) and the sensing mechanism of colorimetric sensor for the detection of Cu(2+) was also discussed. © 2013 Elsevier B.V. All rights reserved.

  5. Carbon nanoparticle for highly sensitive and selective fluorescent detection of mercury(II) ion in aqueous solution.

    PubMed

    Li, Hailong; Zhai, Junfeng; Tian, Jingqi; Luo, Yonglan; Sun, Xuping

    2011-08-15

    In this article, carbon nanoparticles (CNPs) were used as a novel fluorescent sensing platform for highly sensitive and selective Hg(2+) detection. To the best of our knowledge, this is the first example of CNPs obtained from candle soot used in this type of sensor. The general concept used in this approach is based on that adsorption of the fluorescently labeled single-stranded DNA (ssDNA) probe by CNP via π-π stacking interactions between DNA bases and CNP leads to substantial dye fluorescence quenching; however, in the presence of Hg(2+), T-Hg(2+)-T induced hairpin structure does not adsorb on CNP and thus retains the dye fluorescence. A detection limit as low as 10nM was achieved. The present CNP-based biosensor for Hg(2+) detection exhibits remarkable specificity against other possible metal ions. Furthermore, superior selectivity performance was observed when Hg(2+) detection was carried out in the presence of a large amount of other interference ions. Finally, in order to evaluate its potential practical application, Hg(2+) detection was conducted with the use of lake water other than pure buffer and it is believed that it holds great promise for real sample analysis upon further development. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Ultra-sensitive and selective Hg{sup 2+} detection based on fluorescent carbon dots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ruihua; Li, Haitao; Kong, Weiqian

    2013-07-15

    Graphical abstract: Fluorescent carbon dots were efficiently synthesized by one-step sodium hydroxide-assisted reflux method from PEG and demonstrated to show high selectivity toward Hg2+ ions detection. - Highlights: • FCDs were synthesized by one-step sodium hydroxide-assisted reflux method from PEG. • The FCDs emit blue photoluminescence and have upconversion fluorescent property. • The FCDs show ultra-sensitive detective ability for Hg{sup 2+} ions. - Abstract: Fluorescent carbon dots (FCDs) were efficiently synthesized by one-step sodium hydroxide-assisted reflux method from poly(ethylene glycol) (PEG). The obtained FCDs exhibit excellent water-solubility and high stability. Under the UV irradiation, the FCDs could emit bright bluemore » photoluminescence, and also they were found to show excellent up-conversion fluorescence. It was further demonstrated that such FCDs can serve as effective fluorescent sensing platform for Hg{sup 2+} ions detection with ultra-sensitivity and selectivity. The sensing system achieved a limit of detection as low as 1 fM, which is much lower than all the previous reported sensing systems for Hg{sup 2+} ions detection. This FCDs sensing system has been successfully applied for the analysis of Hg{sup 2+} ions in water samples from river, lake, and tap water, showing good practical feasibility.« less

  7. Application of Natural Isotopic Abundance ¹H-¹³C- and ¹H-¹⁵N-Correlated Two-Dimensional NMR for Evaluation of the Structure of Protein Therapeutics.

    PubMed

    Arbogast, Luke W; Brinson, Robert G; Marino, John P

    2016-01-01

    Methods for characterizing the higher-order structure of protein therapeutics are in great demand for establishing consistency in drug manufacturing, for detecting drug product variations resulting from modifications in the manufacturing process, and for comparing a biosimilar to an innovator reference product. In principle, solution NMR can provide a robust approach for characterization of the conformation(s) of protein therapeutics in formulation at atomic resolution. However, molecular weight limitations and the perceived need for stable isotope labeling have to date limited its practical applications in the biopharmaceutical industry. Advances in NMR magnet and console technologies, cryogenically cooled probes, and new rapid acquisition methodologies, particularly selective optimized flip-angle short transient pulse schemes and nonuniform sampling, have greatly ameliorated these limitations. Here, we describe experimental methods for the collection and analysis of 2D (1)H(N)-(15)N-amide- and (1)H-(13)C-methyl-correlated spectra applied to protein drug products at natural isotopic abundance, including representatives from the rapidly growing class of monoclonal antibody (mAb) therapeutics. Practical aspects of experimental setup and data acquisition for both standard and rapid acquisition NMR techniques are described. Furthermore, strategies for the statistical comparison of 2D (1)H(N)-(15)N-amide- and (1)H-(13)C-methyl-correlated spectra are detailed. 2016 Published by Elsevier Inc.

  8. Laser Diagnostics for Reacting Flows

    DTIC Science & Technology

    2010-01-11

    noise characteristics of the diagnostic will be in the shot - noise limit , a fundamental limit of the LIF signal intensity... noise related to the discrete nature of photons. In the shot - noise limit , the fluctuation detection limit can be predicted using nVP B S f f  1...detection limit was shot - noise limited . Figure 2.2.3 illustrates the fluctuation detection limits for line LIF imaging. Figure 2.2.3a

  9. Fire behavior and risk analysis in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1988-01-01

    Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.

  10. Method for the determination of organophosphate insecticides in water, sediment and biota.

    PubMed

    Tse, Hung; Comba, Michael; Alaee, Mehran

    2004-01-01

    A procedure for the determination of 13 organophosphate insecticides (OPs) in water, sediment and biota at low ppb levels is described. Samples were extracted with dichloromethane or acetone/hexane and cleaned up with micro-column silica gel chromatography. Measurements were made by dual capillary column gas chromatography using both nitrogen-phosphorus (NPD) and electron capture (ECD) detection. Recoveries from fortified water samples ranged from 76% to 102% for all sample types. Practical detection limits ranged between 0.003 and 0.029 microg/l in natural water samples, 0.0004-0.005 microg/g w.w. for sediments, and 0.001-0.005 microg/g w.w for biota using the NPD and ECD method. Losses in sediments were experienced when sulphur was removed. Precision and accuracy were not affected in sediment samples where sulphur was not removed.

  11. Probing the gravitational Faraday rotation using quasar X-ray microlensing

    PubMed Central

    Chen, Bin

    2015-01-01

    The effect of gravitational Faraday rotation was predicted in the 1950s, but there is currently no practical method for measuring this effect. Measuring this effect is important because it will provide new evidence for correctness of general relativity, in particular, in the strong field limit. We predict that the observed degree and angle of the X-ray polarization of a cosmologically distant quasar microlensed by the random star field in a foreground galaxy or cluster lens vary rapidly and concurrently with flux during caustic-crossing events using the first simulation of quasar X-ray microlensing polarization light curves. Therefore, it is possible to detect gravitational Faraday rotation by monitoring the X-ray polarization of gravitationally microlensed quasars. Detecting this effect will also confirm the strong gravity nature of quasar X-ray emission. PMID:26574051

  12. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.

    PubMed

    Korun, M; Vodenik, B; Zorko, B

    2018-03-01

    A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Detection of the 35S promoter in transgenic maize via various isothermal amplification techniques: a practical approach.

    PubMed

    Zahradnik, Celine; Kolm, Claudia; Martzy, Roland; Mach, Robert L; Krska, Rudolf; Farnleitner, Andreas H; Brunner, Kurt

    2014-11-01

    In 2003 the European Commission introduced a 0.9% threshold for food and feed products containing genetically modified organism (GMO)-derived components. For commodities containing GMO contents higher than this threshold, labelling is mandatory. To provide a DNA-based rapid and simple detection method suitable for high-throughput screening of GMOs, several isothermal amplification approaches for the 35S promoter were tested: strand displacement amplification, nicking-enzyme amplification reaction, rolling circle amplification, loop-mediated isothermal amplification (LAMP) and helicase-dependent amplification (HDA). The assays developed were tested for specificity in order to distinguish between samples containing genetically modified (GM) maize and non-GM maize. For those assays capable of this discrimination, tests were performed to determine the lower limit of detection. A false-negative rate was determined to rule out whether GMO-positive samples were incorrectly classified as GMO-negative. A robustness test was performed to show reliable detection independent from the instrument used for amplification. The analysis of three GM maize lines showed that only LAMP and HDA were able to differentiate between the GMOs MON810, NK603, and Bt11 and non-GM maize. Furthermore, with the HDA assay it was possible to realize a detection limit as low as 0.5%. A false-negative rate of only 5% for 1% GM maize for all three maize lines shows that HDA has the potential to be used as an alternative strategy for the detection of transgenic maize. All results obtained with the LAMP and HDA assays were compared with the results obtained with a previously reported real-time PCR assay for the 35S promoter in transgenic maize. This study presents two new screening assays for detection of the 35S promoter in transgenic maize by applying the isothermal amplification approaches HDA and LAMP.

  14. Wide field-of-view dual-band multispectral muzzle flash detection

    NASA Astrophysics Data System (ADS)

    Montoya, J.; Melchor, J.; Spiliotis, P.; Taplin, L.

    2013-06-01

    Sensor technologies are undergoing revolutionary advances, as seen in the rapid growth of multispectral methodologies. Increases in spatial, spectral, and temporal resolution, and in breadth of spectral coverage, render feasible sensors that function with unprecedented performance. A system was developed that addresses many of the key hardware requirements for a practical dual-band multispectral acquisition system, including wide field of view and spectral/temporal shift between dual bands. The system was designed using a novel dichroic beam splitter and dual band-pass filter configuration that creates two side-by-side images of a scene on a single sensor. A high-speed CMOS sensor was used to simultaneously capture data from the entire scene in both spectral bands using a short focal-length lens that provided a wide field-of-view. The beam-splitter components were arranged such that the two images were maintained in optical alignment and real-time intra-band processing could be carried out using only simple arithmetic on the image halves. An experiment related to limitations of the system to address multispectral detection requirements was performed. This characterized the system's low spectral variation across its wide field of view. This paper provides lessons learned on the general limitation of key hardware components required for multispectral muzzle flash detection, using the system as a hardware example combined with simulated multispectral muzzle flash and background signatures.

  15. Efficient double-quenching of electrochemiluminescence from CdS:Eu QDs by hemin-graphene-Au nanorods ternary composite for ultrasensitive immunoassay

    PubMed Central

    Liu, Jing; Cui, Meirong; Zhou, Hong; Zhang, Shusheng

    2016-01-01

    A novel ternary composite of hemin-graphene-Au nanorods (H-RGO-Au NRs) with high electrocatalytic activity was synthesized by a simple method. And this ternary composite was firstly used in construction of electrochemiluminescence (ECL) immunosensor due to its double-quenching effect of quantum dots (QDs). Based on the high electrocatalytic activity of ternary complexes for the reduction of H2O2 which acted as the coreactant of QDs-based ECL, as a result, the ECL intensity of QDs decreased. Besides, due to the ECL resonance energy transfer (ECL-RET) strategy between the large amount of Au nanorods (Au NRs) on the ternary composite surface and the CdS:Eu QDs, the ECL intensity of QDs was further quenched. Based on the double-quenching effect, a novel ultrasensitive ECL immunoassay method for detection of carcinoembryonic antigen (CEA) which is used as a model biomarker analyte was proposed. The designed immunoassay method showed a linear range from 0.01 pg mL−1 to 1.0 ng mL−1 with a detection limit of 0.01 pg mL−1. The method showing low detection limit, good stability and acceptable fabrication reproducibility, provided a new approach for ECL immunoassay sensing and significant prospect for practical application. PMID:27460868

  16. A method for limiting data acquisition in a high-resolution gamma-ray spectrometer during On-Site Inspection activities under the Comprehensive Nuclear-Test-Ban Treaty

    NASA Astrophysics Data System (ADS)

    Aviv, O.; Lipshtat, A.

    2018-05-01

    On-Site Inspection (OSI) activities under the Comprehensive Nuclear-Test-Ban Treaty (CTBT) allow limitations to measurement equipment. Thus, certain detectors require modifications to be operated in a restricted mode. The accuracy and reliability of results obtained by a restricted device may be impaired. We present here a method for limiting data acquisition during OSI. Limitations are applied to a high-resolution high-purity germanium detector system, where the vast majority of the acquired data that is not relevant to the inspection is filtered out. The limited spectrum is displayed to the user and allows analysis using standard gamma spectrometry procedures. The proposed method can be incorporated into commercial gamma-ray spectrometers, including both stationary and mobile-based systems. By applying this procedure to more than 1000 spectra, representing various scenarios, we show that partial data are sufficient for reaching reliable conclusions. A comprehensive survey of potential false-positive identifications of various radionuclides is presented as well. It is evident from the results that the analysis of a limited spectrum is practically identical to that of a standard spectrum in terms of detection and quantification of OSI-relevant radionuclides. A future limited system can be developed making use of the principles outlined by the suggested method.

  17. Limited angle tomographic breast imaging: A comparison of parallel beam and pinhole collimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wessell, D.E.; Kadrmas, D.J.; Frey, E.C.

    1996-12-31

    Results from clinical trials have suggested no improvement in lesion detection with parallel hole SPECT scintimammography (SM) with Tc-99m over parallel hole planar SM. In this initial investigation, we have elucidated some of the unique requirements of SPECT SM. With these requirements in mind, we have begun to develop practical data acquisition and reconstruction strategies that can reduce image artifacts and improve image quality. In this paper we investigate limited angle orbits for both parallel hole and pinhole SPECT SM. Singular Value Decomposition (SVD) is used to analyze the artifacts associated with the limited angle orbits. Maximum likelihood expectation maximizationmore » (MLEM) reconstructions are then used to examine the effects of attenuation compensation on the quality of the reconstructed image. All simulations are performed using the 3D-MCAT breast phantom. The results of these simulation studies demonstrate that limited angle SPECT SM is feasible, that attenuation correction is needed for accurate reconstructions, and that pinhole SPECT SM may have an advantage over parallel hole SPECT SM in terms of improved image quality and reduced image artifacts.« less

  18. Non-adherence in seniors with dementia - a serious problem of routine clinical practice.

    PubMed

    Lužný, Jan; Ivanová, Kateřina; Juríčková, Lubica

    2014-01-01

    Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment - a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  19. Ochratoxin A in cereal-based baby foods: occurrence and safety evaluation.

    PubMed

    Beretta, B; De Domenico, R; Gaiaschi, A; Ballabio, C; Galli, C L; Gigliotti, C; Restani, P

    2002-01-01

    Ochratoxin A is a typical cereal contaminant with strong nephrotoxic activity. To estimate the quantity of ochratoxin A that can be taken in by a child in the weaning period, several samples of cereal-based baby foods were analysed. Although most samples analysed contained ochratoxin A in undetectable amounts or below the Italian legal limit of 0.5 microg kg(-1), some irregular products were found. In particular, the analyses of the 119 batches (338 samples) of baby foods considered indicated that: 20 batches (16.8%) contained detectable quantities of ochratoxin A and four of these (3.4% of the total) contained ochratoxin A above the Italian permitted value. All samples coming from agricultural practices based on integrated pest management contained undetectable amounts of ochratoxin A, while approximately 5% of batches coming from conventional and organic agricultural practices were above the legal limit. On the basis of the established provisional tolerable weekly intake (PTWI), there is no significant toxicological risk for a child who occasionally consumes a formula with ochratoxin concentration slightly above the permitted level. However, stricter controls have to be applied to reject the batches containing irregular concentrations of ochratoxin A.

  20. Quantitation in chiral capillary electrophoresis: theoretical and practical considerations.

    PubMed

    D'Hulst, A; Verbeke, N

    1994-06-01

    Capillary electrophoresis (CE) represents a decisive step forward in stereoselective analysis. The present paper deals with the theoretical aspects of the quantitation of peak separation in chiral CE. Because peak shape is very different in CE with respect to high performance liquid chromatography (HPLC), the resolution factor Rs, commonly used to describe the extent of separation between enantiomers as well as unrelated compounds, is demonstrated to be of limited value for the assessment of chiral separations in CE. Instead, the conjunct use of a relative chiral separation factor (RCS) and the percent chiral separation (% CS) is advocated. An array of examples is given to illustrate this. The practical aspects of method development using maltodextrins--which have been proposed previously as a major innovation in chiral selectors applicable in CE--are documented with the stereoselective analysis of coumarinic anticoagulant drugs. The possibilities of quantitation using CE were explored under two extreme conditions. Using ibuprofen, it has been demonstrated that enantiomeric excess determinations are possible down to a 1% level of optical contamination and stereoselective determinations are still possible with a good precision near the detection limit, increasing sample load by very long injection times. The theoretical aspects of this possibility are addressed in the discussion.

  1. Chained lightning: part III--Emerging technology, novel therapeutic strategies, and new energy modalities for radiosurgery.

    PubMed

    Hoh, Daniel J; Liu, Charles Y; Chen, Joseph C T; Pagnini, Paul G; Yu, Cheng; Wang, Michael Y; Apuzzo, Michael L J

    2007-12-01

    Radiosurgery is fundamentally the harnessing of energy and delivering it to a focal target for a therapeutic effect. The evolution of radiosurgical technology and practice has served toward refining methodologies for better conformal energy delivery. In the past, this has resulted in developing strategies for improved beam generation and delivery. Ultimately, however, our current instrumentation and treatment modalities may be approaching a practical limit with regard to further optimizing energy containment. In looking forward, several strategies are emerging to circumvent these limitations and improve conformal radiosurgery. Refinement of imaging techniques through functional imaging and nanoprobes for cancer detection may benefit lesion localization and targeting. Methods for enhancing the biological effect while reducing radiation-induced changes are being examined through dose fractionation schedules. Radiosensitizers and photosensitizers are being investigated as agents for modulating the biological response of tissues to radiation and alternative energy forms. Discovery of new energy modalities is being pursued through development of microplanar beams, free electron lasers, and high-intensity focused ultrasound. The exploration of these future possibilities will provide the tools for radiosurgical treatment of a broader spectrum of diseases for the next generation.

  2. 40 CFR 445.11 - Effluent limitations attainable by the application of the best practicable control technology...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 445.11 Section 445.11... attainable by the application of the best practicable control technology currently available (BPT). Except as... the following effluent limitations which represent the application of BPT: Effluent Limitations...

  3. The microbial quality of drinking water in Manonyane community: Maseru District (Lesotho).

    PubMed

    Gwimbi, P

    2011-09-01

    Provision of good quality household drinking water is an important means of improving public health in rural communities especially in Africa; and is the rationale behind protecting drinking water sources and promoting healthy practices at and around such sources. To examine the microbial content of drinking water from different types of drinking water sources in Manonyane community of Lesotho. The community's hygienic practices around the water sources are also assessed to establish their contribution to water quality. Water samples from thirty five water sources comprising 22 springs, 6 open wells, 6 boreholes and 1 open reservoir were assessed. Total coliform and Escherichia coli bacteria were analyzed in water sampled. Results of the tests were compared with the prescribed World Health Organization desirable limits. A household survey and field observations were conducted to assess the hygienic conditions and practices at and around the water sources. Total coliform were detected in 97% and Escherichia coli in 71% of the water samples. The concentration levels of Total coliform and Escherichia coli were above the permissible limits of the World Health Organization drinking water quality guidelines in each case. Protected sources had significantly less number of colony forming units (cfu) per 100 ml of water sample compared to unprotected sources (56% versus 95%, p < 0.05). Similarly in terms of Escherichia coli, protected sources had less counts (7% versus 40%, p < 0.05) compared with those from unprotected sources. Hygiene conditions and practices that seemed to potentially contribute increased total coliform and Escherichia coli counts included non protection of water sources from livestock faeces, laundry practices, and water sources being down slope of pit latrines in some cases. These findings suggest source water protection and good hygiene practices can improve the quality of household drinking water where disinfection is not available. The results also suggest important lines of inquiry and provide support and input for environmental and public health programmes, particularly those related to water and sanitation.

  4. Management of hypertension at the community level in sub-Saharan Africa (SSA): towards a rational use of available resources.

    PubMed

    Twagirumukiza, M; Van Bortel, L M

    2011-01-01

    Hypertension is emerging in many developing nations as a leading cause of cardiovascular mortality, morbidity and disability in adults. In sub-Saharan African (SSA) countries it has specificities such as occurring in young and active adults, resulting in severe complications dominated by heart failure and taking place in limited-resource settings in which an individual's access to treatment (affordability) is very limited. Within this context of restrained economic conditions, the greatest gains for SSA in controlling the hypertension epidemic lie in its prevention. Attempts should be made to detect hypertensive patients early before irreversible organ damage becomes apparent, and to provide them with the best possible and affordable non-pharmacological and pharmacological treatment. Therefore, efforts should be made for detection and early management at the community level. In this context, a standardized algorithm of management can help in the rational use of available resources. Although many international and regional guidelines have been published, they cannot apply to SSA settings because the economy of the countries and affordability of the patients do not allow access to advocated treatment. In addition, none of them suggest a clear algorithm of management for limited-resource settings at the community level. In line with available data and analysing existing guidelines, a practical algorithm for management of hypertension at the community level, including treatment affordability, has been suggested in the present work.

  5. Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2

    PubMed Central

    Du, Hong; El-Mohri, Youcef; Zhao, Qihua; Su, Zhong; Yamamoto, Jin; Wang, Yi

    2009-01-01

    Active matrix, flat-panel x-ray imagers based on a-Si:H thin film transistors offer many advantages and are widely utilized in medical imaging applications. Unfortunately, the detective quantum efficiency (DQE) of conventional flat-panel imagers incorporating scintillators or a-Se photoconductors is significantly limited by their relatively modest signal to noise ratio, particularly in applications involving low x-ray exposures or high spatial resolution. For this reason, polycrystalline HgI2 is of considerable interest by virtue of its low effective work function, high atomic number, and the possibility of large-area deposition. In this study, a detailed investigation of the properties of prototype, flat-panel arrays coated with two forms of this high-gain photoconductor are reported. Encouragingly, high x-ray sensitivity, low dark current, and spatial resolution close to the theoretical limits were observed from a number of prototypes. In addition, input-quantum-limited DQE performance was measured from one of the prototypes at relatively low exposures. However, high levels of charge trapping, lag, and polarization, as well as pixel-to-pixel variations in x-ray sensitivity are of concern. While the results of the current study are promising, further development will be required to realize prototypes exhibiting the characteristics necessary to allow practical implementation of this approach. PMID:18296765

  6. Review of Current Data Exchange Practices: Providing Descriptive Data to Assist with Building Operations Decisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Livingood, W.; Stein, J.; Considine, T.

    Retailers who participate in the U.S. Department of Energy Commercial Building Energy Alliances (CBEA) identified the need to enhance communication standards. The means are available to collect massive numbers of buildings operational data, but CBEA members have difficulty transforming the data into usable information and energy-saving actions. Implementing algorithms for automated fault detection and diagnostics and linking building operational data to computerized maintenance management systems are important steps in the right direction, but have limited scalability for large building portfolios because the algorithms must be configured for each building.

  7. [Improvement of the determination method of benzene, toluene, ethylbenzene and xylene(BTEX) in water using activated carbon fiber solid-phase microextraction/gas chromatography-mass spectrometry(GC-MS)].

    PubMed

    Jia, Jin-ping; Feng, Xue; Fang, Neng-hu; Huang, Jia-liang

    2002-01-01

    The methods of direct injection, carbon disulfide extraction and activated carbon fiber solid-phase microextraction/GC-MS, usually used in the determination of BTEX in water matrix, are compared and discussed. Experimental data of linearity, precision and limit of detection illustrate that the last one is better than the two other methods. This method was tested by the practical sample experiments and expected to be a simple and sensitive new method for the analysis of BTEX in water.

  8. Pediatric regional anesthesia: what is the current safety record?

    PubMed

    Polaner, David M; Drescher, Jessica

    2011-07-01

    The use of regional anesthetics, whether as adjuncts, primary anesthetics or postoperative analgesia, is increasingly common in pediatric practice. Data on safety remain limited because of the paucity of very large-scale prospective studies that are necessary to detect low incidence events, although several studies either have been published or have reported preliminary results. This paper will review the data on complications and risk in pediatric regional anesthesia. Information currently available suggests that regional blockade, when performed properly, carries a very low risk of morbidity and mortality in appropriately selected infants and children. © 2010 Blackwell Publishing Ltd.

  9. Evaluation of the biophysical limitations on photosynthesis of four varietals of Brassica rapa

    NASA Astrophysics Data System (ADS)

    Pleban, J. R.; Mackay, D. S.; Aston, T.; Ewers, B.; Weinig, C.

    2014-12-01

    Evaluating performance of agricultural varietals can support the identification of genotypes that will increase yield and can inform management practices. The biophysical limitations of photosynthesis are amongst the key factors that necessitate evaluation. This study evaluated how four biophysical limitations on photosynthesis, stomatal response to vapor pressure deficit, maximum carboxylation rate by Rubisco (Ac), rate of photosynthetic electron transport (Aj) and triose phosphate use (At) vary between four Brassica rapa genotypes. Leaf gas exchange data was used in an ecophysiological process model to conduct this evaluation. The Terrestrial Regional Ecosystem Exchange Simulator (TREES) integrates the carbon uptake and utilization rate limiting factors for plant growth. A Bayesian framework integrated in TREES here used net A as the target to estimate the four limiting factors for each genotype. As a first step the Bayesian framework was used for outlier detection, with data points outside the 95% confidence interval of model estimation eliminated. Next parameter estimation facilitated the evaluation of how the limiting factors on A different between genotypes. Parameters evaluated included maximum carboxylation rate (Vcmax), quantum yield (ϕJ), the ratio between Vc-max and electron transport rate (J), and trios phosphate utilization (TPU). Finally, as trios phosphate utilization has been shown to not play major role in the limiting A in many plants, the inclusion of At in models was evaluated using deviance information criteria (DIC). The outlier detection resulted in a narrowing in the estimated parameter distributions allowing for greater differentiation of genotypes. Results show genotypes vary in the how limitations shape assimilation. The range in Vc-max , a key parameter in Ac, was 203.2 - 223.9 umol m-2 s-1 while the range in ϕJ, a key parameter in AJ, was 0.463 - 0.497 umol m-2 s-1. The added complexity of the TPU limitation did not improve model performance in the genotypes assessed based on DIC. By identifying how varietals differ in their biophysical limitations on photosynthesis genotype selection can be informed for agricultural goals. Further work aims at applying this approach to a fifth limiting factor on photosynthesis, mesophyll conductance.

  10. Making it stick: convection, reaction and diffusion in surface-based biosensors.

    PubMed

    Squires, Todd M; Messinger, Robert J; Manalis, Scott R

    2008-04-01

    The past decade has seen researchers develop and apply novel technologies for biomolecular detection, at times approaching hard limits imposed by physics and chemistry. In nearly all sensors, the transport of target molecules to the sensor can play as critical a role as the chemical reaction itself in governing binding kinetics, and ultimately performance. Yet rarely does an analysis of the interplay between diffusion, convection and reaction motivate experimental design or interpretation. Here we develop a physically intuitive and practical understanding of analyte transport for researchers who develop and employ biosensors based on surface capture. We explore the qualitatively distinct behaviors that result, develop rules of thumb to quickly determine how a given system will behave, and derive order-of-magnitude estimates for fundamental quantities of interest, such as fluxes, collection rates and equilibration times. We pay particular attention to collection limits for micro- and nanoscale sensors, and highlight unexplained discrepancies between reported values and theoretical limits.

  11. Limits of detection and decision. Part 4

    NASA Astrophysics Data System (ADS)

    Voigtman, E.

    2008-02-01

    Probability density functions (PDFs) have been derived for a number of commonly used limit of detection definitions, including several variants of the Relative Standard Deviation of the Background-Background Equivalent Concentration (RSDB-BEC) method, for a simple linear chemical measurement system (CMS) having homoscedastic, Gaussian measurement noise and using ordinary least squares (OLS) processing. All of these detection limit definitions serve as both decision and detection limits, thereby implicitly resulting in 50% rates of Type 2 errors. It has been demonstrated that these are closely related to Currie decision limits, if the coverage factor, k, is properly defined, and that all of the PDFs are scaled reciprocals of noncentral t variates. All of the detection limits have well-defined upper and lower limits, thereby resulting in finite moments and confidence limits, and the problem of estimating the noncentrality parameter has been addressed. As in Parts 1-3, extensive Monte Carlo simulations were performed and all the simulation results were found to be in excellent agreement with the derived theoretical expressions. Specific recommendations for harmonization of detection limit methodology have also been made.

  12. Coronary artery disease detection - limitations of stress testing in left ventricular dysfunction

    PubMed Central

    Bomb, Ritin; Kumar, Senthil; Chockalingam, Anand

    2017-01-01

    Incidental diagnosis of left ventricular systolic dysfunction (LVD) is common in clinical practice. The prevalence of asymptomatic LVD (Ejection Fraction, EF < 50%) is 6.0% in men and 0.8% in women and is twice as common as symptomatic LVD. The timely and definitive exclusion of an ischemic etiology is central to optimizing care and reducing mortality in LVD. Advances in cardiovascular imaging provide many options for imaging of patients with left ventricular dysfunction. Clinician experience, patient endurance, imaging modality characteristics, cost and safety determine the choice of testing. In this review, we have compared the diagnostic utility of established tests - nuclear and echocardiographic stress testing with newer techniques like coronary computerized tomography and cardiac magnetic resonance imaging and highlight their inherent limitations in patients with underlying left ventricular dysfunction. PMID:28515848

  13. Modified SPC for short run test and measurement process in multi-stations

    NASA Astrophysics Data System (ADS)

    Koh, C. K.; Chin, J. F.; Kamaruddin, S.

    2018-03-01

    Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.

  14. Promotion, prevention and protection: interventions at the population- and community-levels for mental, neurological and substance use disorders in low- and middle-income countries.

    PubMed

    Petersen, Inge; Evans-Lacko, Sara; Semrau, Maya; Barry, Margaret M; Chisholm, Dan; Gronholm, Petra; Egbe, Catherine O; Thornicroft, Graham

    2016-01-01

    In addition to services within the health system, interventions at the population and community levels are also important for the promotion of mental health, primary prevention of mental, neurological and substance use (MNS) disorders, identification and case detection of MNS disorders; and to a lesser degree treatment, care and rehabilitation. This study aims to identify "best practice" and "good practice" interventions that can feasibly be delivered at these population- and community-levels in low- and middle-income countries (LMICs), to aid the identification of resource efficiencies and allocation in LMICs. A narrative review was conducted given the wide range of relevant interventions. Expert consensus was used to identify "best practice" at the population-level on the basis of existing quasi-experimental natural experiments and cost effectiveness, with small scale emerging and promising evidence comprising "good practice". At the community-level, using expert consensus, the ACE (Assessing Cost-Effectiveness in Prevention Project) grading system was used to differentiate "best practice" interventions with sufficient evidence from "good practice" interventions with limited but promising evidence. At the population-level, laws and regulations to control alcohol demand and restrict access to lethal means of suicide were considered "best practice". Child protection laws, improved control of neurocysticercosis and mass awareness campaigns were identified as "good practice". At the community level, socio-emotional learning programmes in schools and parenting programmes during infancy were identified as "best practice". The following were all identified as "good practice": Integrating mental health promotion strategies into workplace occupational health and safety policies; mental health information and awareness programmes as well as detection of MNS disorders in schools; early child enrichment/preschool educational programs and parenting programs for children aged 2-14 years; gender equity and/or economic empowerment programs for vulnerable groups; training of gatekeepers to identify people with MNS disorders in the community; and training non-specialist community members at a neighbourhood level to assist with community-based support and rehabilitation of people with mental disorders. Interventions provided at the population- and community-levels have an important role to play in promoting mental health, preventing the onset, and protecting those with MNS disorders. The importance of inter-sectoral engagement and the need for further research on interventions at these levels in LMICs is highlighted.

  15. Increased detection of Barrett’s esophagus and esophageal dysplasia with adjunctive use of wide-area transepithelial sample with three-dimensional computer-assisted analysis (WATS)

    PubMed Central

    Gross, Seth A; Smith, Michael S; Kaul, Vivek

    2017-01-01

    Background Barrett’s esophagus (BE) and esophageal dysplasia (ED) are frequently missed during screening and surveillance esophagoscopy because of sampling error associated with four-quadrant random forceps biopsy (FB). Aim The aim of this article is to determine if wide-area transepithelial sampling with three-dimensional computer-assisted analysis (WATS) used adjunctively with FB can increase the detection of BE and ED. Methods In this multicenter prospective trial, patients screened for suspected BE and those with known BE undergoing surveillance were enrolled. Patients at 25 community-based practices underwent WATS adjunctively to targeted FB and random four-quadrant FB. Results Of 4203 patients, 594 were diagnosed with BE by FB alone, and 493 additional cases were detected by adding WATS, increasing the overall detection of BE by 83% (493/594, 95% CI 74%–93%). Low-grade dysplasia (LGD) was diagnosed in 26 patients by FB alone, and 23 additional cases were detected by adding WATS, increasing the detection of LGD by 88.5% (23/26, 95% CI 48%–160%). Conclusions Adjunctive use of WATS to FB significantly improves the detection of both BE and ED. Sampling error, an inherent limitation associated with screening and surveillance, can be improved with WATS allowing better informed decisions to be made about the management and subsequent treatment of these patients. PMID:29881608

  16. Development of a Reverse Transcription Loop-Mediated Isothermal Amplification Method for the Rapid Detection of Subtype H7N9 Avian Influenza Virus

    PubMed Central

    Bao, Hongmei; Zhao, Yuhui; Wang, Yunhe; Xu, Xiaolong; Shi, Jianzhong; Zeng, Xianying; Wang, Xiurong; Chen, Hualan

    2014-01-01

    A novel influenza A (H7N9) virus has emerged in China. To rapidly detect this virus from clinical samples, we developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of the H7N9 virus. The minimum detection limit of the RT-LAMP assay was 0.01 PFU H7N9 virus, making this method 100-fold more sensitive to the detection of the H7N9 virus than conventional RT-PCR. The H7N9 virus RT-LAMP assays can efficiently detect different sources of H7N9 influenza virus RNA (from chickens, pigeons, the environment, and humans). No cross-reactive amplification with the RNA of other subtype influenza viruses or of other avian respiratory viruses was observed. The assays can effectively detect H7N9 influenza virus RNA in drinking water, soil, cloacal swab, and tracheal swab samples that were collected from live poultry markets, as well as human H7N9 virus, in less than 30 min. These results suggest that the H7N9 virus RT-LAMP assays were efficient, practical, and rapid diagnostic methods for the epidemiological surveillance and diagnosis of influenza A (H7N9) virus from different resource samples. PMID:24689044

  17. Automatic on-line detection system design research on internal defects of metal materials based on optical fiber F-P sensing technology

    NASA Astrophysics Data System (ADS)

    Xia, Liu; Shan, Ning; Chao, Ban; Caoshan, Wang

    2016-10-01

    Metal materials have been used in aerospace and other industrial fields widely because of its excellent characteristics, so its internal defects detection is very important. Ultrasound technology is used widely in the fields of nondestructive detection because of its excellent characteristic. But the conventional detection instrument for ultrasound, which has shortcomings such as low intelligent level and long development cycles, limits its development. In this paper, the theory of ultrasound detection is analyzed. A computational method of the defects distributional position is given. The non-contact type optical fiber F-P interference cavity structure is designed and the length of origin cavity is given. The real-time on-line ultrasound detecting experiment devices for internal defects of metal materials is established based on the optical fiber F-P sensing system. The virtual instrument of automation ultrasound detection internal defects is developed based on LabVIEW software and the experimental study is carried out. The results show that this system can be used in internal defect real-time on-line locating of engineering structures effectively. This system has higher measurement precision. Relative error is 6.7%. It can be met the requirement of engineering practice. The system is characterized by simple operation, easy realization. The software has a friendly interface, good expansibility, and high intelligent level.

  18. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment

    PubMed Central

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-01-01

    Digital PCR has developed rapidly since it was first reported in the 1990s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products. PMID:26239916

  19. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  20. Development of a colloidal gold immunochromatographic test strip for detection of lymphocystis disease virus in fish.

    PubMed

    Sheng, X Z; Song, J L; Zhan, W B

    2012-10-01

    To develop a gold immunochromatographic test strip for on-site rapid detection of lymphocystis disease virus (LCDV). Monodispersional colloidal gold and gold-labelled anti-LCDV monoclonal antibody (McAb) 2D11 were prepared and characterized by UV-visible spectroscopy and transmission electron microscopy. Gold-labelled probe was used as the detection antibody, and goat anti-mouse IgG at the control line and anti-LCDV McAb 1A8 at the test line of the test strip served as the capture antibody. The positive results could be easily judged by the presence of a red test line with naked eye within 10 min. The test strip, in good agreement with enzyme-linked immunosorbent assay and dot-blotting in sensitivity and LCDV detection, gave a detection limit of 1 μg ml(-1) of LCDV and was stable for 6 months at room temperature and 12 months at 4°C. The test strip was specific, simple and convenient for rapid detection of LCDV presenting good stability and reproducibility. This ready-to-use test strip allows on-site rapid detection of LCDV in fish without the requirement of specialized equipments and professional personnel, which could augment the practical application for diagnosis of LCDV even in disadvantage areas. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  1. Biosensing near the neutrality point of graphene

    PubMed Central

    Fu, Wangyang; Feng, Lingyan; Panaitov, Gregory; Kireev, Dmitry; Mayer, Dirk; Offenhäusser, Andreas; Krause, Hans-Joachim

    2017-01-01

    Over the past decade, the richness of electronic properties of graphene has attracted enormous interest for electrically detecting chemical and biological species using this two-dimensional material. However, the creation of practical graphene electronic sensors greatly depends on our ability to understand and maintain a low level of electronic noise, the fundamental reason limiting the sensor resolution. Conventionally, to reach the largest sensing response, graphene transistors are operated at the point of maximum transconductance, where 1/f noise is found to be unfavorably high and poses a major limitation in any attempt to further improve the device sensitivity. We show that operating a graphene transistor in an ambipolar mode near its neutrality point can markedly reduce the 1/f noise in graphene. Remarkably, our data reveal that this reduction in the electronic noise is achieved with uncompromised sensing response of the graphene chips and thus significantly improving the signal-to-noise ratio—compared to that of a conventionally operated graphene transistor for conductance measurement. As a proof-of-concept demonstration of the usage of the aforementioned new sensing scheme to a broader range of biochemical sensing applications, we selected an HIV-related DNA hybridization as the test bed and achieved detections at picomolar concentrations. PMID:29075669

  2. Application of nickel zinc ferrite/graphene nanocomposite as a modifier for fabrication of a sensitive electrochemical sensor for determination of omeprazole in real samples.

    PubMed

    Afkhami, Abbas; Bahiraei, Atousa; Madrakian, Tayyebeh

    2017-06-01

    In the present study, a simple and highly sensitive sensor for the determination of omeprazole based on nickel-zinc ferrite/graphene modified glassy carbon electrode is reported. The morphology and electro analytical performance of the fabricated sensor were characterized with X-ray diffraction spectrometry, Fourier transform infrared spectrometry, scanning electron microscopy, electrochemical impedance spectroscopy, cyclic voltammetry, differential pulse voltammetry and operation of the sensor. Results were compared with those achieved at the graphene modified glassy carbon electrode and bare glassy carbon electrode. Under the optimized experimental conditions, linear response was over the range of 0.03-100.0µmolL -1 . The lower detection limit was found to be 0.015µmolL -1 . The effect of different interferences on the anodic current response of OMZ was investigated. By measuring the concentrations of omeprazole in plasma and pharmaceutical samples, the practical application of the modified electrode was evaluated. This revealed that the nickel-zinc ferrite/graphene modified glassy carbon electrode shows excellent analytical performance for the determination of omeprazole with a very low detection limit, high sensitivity, and very good accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Evaluation of a hydrophilic interaction liquid chromatography design space for sugars and sugar alcohols.

    PubMed

    Hetrick, Evan M; Kramer, Timothy T; Risley, Donald S

    2017-03-17

    Based on a column-screening exercise, a column ranking system was developed for sample mixtures containing any combination of 26 sugar and sugar alcohol analytes using 16 polar stationary phases in the HILIC mode with acetonitrile/water or acetone/water mobile phases. Each analyte was evaluated on the HILIC columns with gradient elution and the subsequent chromatography data was compiled into a statistical software package where any subset of the analytes can be selected and the columns are then ranked by the greatest separation. Since these analytes lack chromophores, aerosol-based detectors, including an evaporative light scattering detector (ELSD) and a charged aerosol detector (CAD) were employed for qualitative and quantitative detection. Example qualitative applications are provided to illustrate the practicality and efficiency of this HILIC column ranking. Furthermore, the design-space approach was used as a starting point for a quantitative method for the trace analysis of glucose in trehalose samples in a complex matrix. Knowledge gained from evaluating the design-space led to rapid development of a capable method as demonstrated through validation of the following parameters: specificity, accuracy, precision, linearity, limit of quantitation, limit of detection, and range. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Medical and health physics management of a plutonium wound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.; Decker, W.A.; Swint, M.J.

    1988-04-01

    A puncture wound contaminated with plutonium and americium has provided an excellent case study for dealing with internal contamination. This case provides an opportunity to examine the effectiveness of diagnostic techniques, therapeutic techniques, dose assessment practices, and case management philosophy. The wound deposited 48 kBq of transuranic alpha activity in the right index finger. Minor surgery reduced the long-term wound burden to about 5.4 kBq. Chelation therapy with DTPA lasted 17 months and resulted in urinary excretion of about 7 kBq of the deposited activity. Therapy appears to have been effective in limiting early uptake and internal doses from thismore » wound. However, the possibility of slow future uptake from the wound exists. Thus, estimating long-term uptake and dose is difficult. In vivo measurements indicate that residual wound contamination is essentially constant. Within three weeks of the injury, an initial measurable liver burden was reduced by chelation therapy to below detectable limits, and no subsequent build-up has been observed. However, there is indication of a gradually increasing skeleton burden. The axillary lymph nodes have shown relatively constant, detectable activity. 8 refs., 3 figs.« less

  5. Rayleigh-wave diffractions due to a void in the layered half space

    USGS Publications Warehouse

    Xia, J.; Xu, Y.; Miller, R.D.; Nyquist, Jonathan E.

    2006-01-01

    Void detection is challenging due to the complexity of near-surface materials and the limited resolution of geophysical methods. Although multichannel, high-frequency, surface-wave techniques can provide reliable shear (S)-wave velocities in different geological settings, they are not suitable for detecting voids directly based on anomalies of the S-wave velocity because of limitations on the resolution of S-wave velocity profiles inverted from surface-wave phase velocities. Xia et al. (2006a) derived a Rayleigh-wave diffraction traveltime equation due to a void in the homogeneous half space. Encouraging results of directly detecting a void from Rayleigh-wave diffractions were presented (Xia et al., 2006a). In this paper we used four two-dimensional square voids in the layered half space to demonstrate the feasibility of detecting a void with Rayleigh-wave diffractions. Rayleigh-wave diffractions were recognizable for all these models after removing direct surface waves by F-K filtering. We evaluate the feasibility of applying the Rayleigh-wave diffraction traveltime equation to a void in the layered earth model. The phase velocity of diffracted Rayleigh waves is predominately determined by surrounding materials of a void. The modeling results demonstrate that the Rayleigh-wave diffraction traveltime equation due to a void in the homogeneous half space can be applied to the case of a void in the layered half space. In practice, only two diffraction times are necessary to define the depth to the top of a void and the average velocity of diffracted Rayleigh waves. ?? 2005 Society of Exploration Geophysicists.

  6. 40 CFR 63.2342 - When do I have to comply with this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... work practice standards for each such emission source based on the schedule found in paragraph (b) of..., operating limits, and work practice standards in this subpart for each such emission source based on the... with the emission limitations, operating limits, and work practice standards for new and reconstructed...

  7. 40 CFR 63.2342 - When do I have to comply with this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... work practice standards for each such emission source based on the schedule found in paragraph (b) of..., operating limits, and work practice standards in this subpart for each such emission source based on the... with the emission limitations, operating limits, and work practice standards for new and reconstructed...

  8. 12 CFR 308.12 - Construction of time limits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Construction of time limits. 308.12 Section 308.12 Banks and Banking FEDERAL DEPOSIT INSURANCE CORPORATION PROCEDURE AND RULES OF PRACTICE RULES OF PRACTICE AND PROCEDURE Uniform Rules of Practice and Procedure § 308.12 Construction of time limits. (a...

  9. Insight From the Statistics of Nothing: Estimating Limits of Change Detection Using Inferred No-Change Areas in DEM Difference Maps and Application to Landslide Hazard Studies

    NASA Astrophysics Data System (ADS)

    Haneberg, W. C.

    2017-12-01

    Remote characterization of new landslides or areas of ongoing movement using differences in high resolution digital elevation models (DEMs) created through time, for example before and after major rains or earthquakes, is an attractive proposition. In the case of large catastrophic landslides, changes may be apparent enough that simple subtraction suffices. In other cases, statistical noise can obscure landslide signatures and place practical limits on detection. In ideal cases on land, GPS surveys of representative areas at the time of DEM creation can quantify the inherent errors. In less-than-ideal terrestrial cases and virtually all submarine cases, it may be impractical or impossible to independently estimate the DEM errors. Examining DEM difference statistics for areas reasonably inferred to have no change, however, can provide insight into the limits of detectability. Data from inferred no-change areas of airborne LiDAR DEM difference maps of the 2014 Oso, Washington landslide and landslide-prone colluvium slopes along the Ohio River valley in northern Kentucky, show that DEM difference maps can have non-zero mean and slope dependent error components consistent with published studies of DEM errors. Statistical thresholds derived from DEM difference error and slope data can help to distinguish between DEM differences that are likely real—and which may indicate landsliding—from those that are likely spurious or irrelevant. This presentation describes and compares two different approaches, one based upon a heuristic assumption about the proportion of the study area likely covered by new landslides and another based upon the amount of change necessary to ensure difference at a specified level of probability.

  10. Design of experiments for amino acid extraction from tobacco leaves and their subsequent determination by capillary zone electrophoresis.

    PubMed

    Hodek, Ondřej; Křížek, Tomáš; Coufal, Pavel; Ryšlavá, Helena

    2017-03-01

    In this study, we optimized a method for the determination of free amino acids in Nicotiana tabacum leaves. Capillary electrophoresis with contactless conductivity detector was used for the separation of 20 proteinogenic amino acids in acidic background electrolyte. Subsequently, the conditions of extraction with HCl were optimized for the highest extraction yield of the amino acids because sample treatment of plant materials brings some specific challenges. Central composite face-centered design with fractional factorial design was used in order to evaluate the significance of selected factors (HCl volume, HCl concentration, sonication, shaking) on the extraction process. In addition, the composite design helped us to find the optimal values for each factor using the response surface method. The limits of detection and limits of quantification for the 20 proteinogenic amino acids were found to be in the order of 10 -5 and 10 -4  mol l -1 , respectively. Addition of acetonitrile to the sample was tested as a method commonly used to decrease limits of detection. Ambiguous results of this experiment pointed out some features of plant extract samples, which often required specific approaches. Suitability of the method for metabolomic studies was tested by analysis of a real sample, in which all amino acids, except for L-methionine and L-cysteine, were successfully detected. The optimized extraction process together with the capillary electrophoresis method can be used for the determination of proteinogenic amino acids in plant materials. The resulting inexpensive, simple, and robust method is well suited for various metabolomic studies in plants. As such, the method represents a valuable tool for research and practical application in the fields of biology, biochemistry, and agriculture.

  11. Simultaneous determination of nickel and copper by H-point standard addition method-first-order derivative spectrophotometry in plant samples after separation and preconcentration on modified natural clinoptilolite as a new sorbent.

    PubMed

    Roohparvar, Rasool; Taher, Mohammad Ali; Mohadesi, Alireza

    2008-01-01

    For the simultaneous determination of nickel(ll) and copper(ll) in plant samples, a rapid and accurate method was developed. In this method, solid-phase extraction (SPE) and first-order derivative spectrophotometry (FDS) are combined, and the result is coupled with the H-point standard addition method (HPSAM). Compared with normal spectrophotometry, derivative spectrophotometry offers the advantages of increased selectivity and sensitivity. As there is no need for carrying out any pretreatment of the sample, the spectrophotometry method is easy, but because of a high detection limit, it is not so practical. In order to decrease the detection limit, it is suggested to combine spectrophotometry with a preconcentration method such as SPE. In the present work, after separation and preconcentration of Ni(ll) and Cu(ll) on modified clinoptilolite zeolite that is loaded with 2-[1-(2-hydroxy-5-sulforphenyl)-3-phenyl-5-formaza-no]-benzoic acid monosodium salt (zincon) as a selective chromogenic reagent, FDS-HPSAM, which is a simple and selective spectrophotometric method, has been applied for simultaneous determination of these ions. With optimum conditions, the detection limit in original solutions is 0.7 and 0.5 ng/mL, respectively, for nickel and copper. The linear concentration ranges in the proposed method for nickel and copper ions in original solutions are 1.1 to 3.0 x 10(3) and 0.9 to 2.0 x 10(3) ng/mL, respectively. The recommended procedure is applied to successful determination of Cu(ll) and Ni(ll) in standard and real samples.

  12. Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors

    NASA Astrophysics Data System (ADS)

    Zhang, Teng; Danilishin, Stefan L.; Steinlechner, Sebastian; Barr, Bryan W.; Bell, Angus S.; Dupej, Peter; Gräf, Christian; Hennig, Jan-Simon; Houston, E. Alasdair; Huttner, Sabina H.; Leavey, Sean S.; Pascucci, Daniela; Sorazu, Borja; Spencer, Andrew; Wright, Jennifer; Strain, Kenneth A.; Hild, Stefan

    2017-03-01

    With the recent detection of gravitational waves (GWs), marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWDs) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum-noise (QN) limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third-generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high-order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum-noise limited sensitivity is independent of the actual interferometer configuration; e.g. Michelson and Sagnac interferometers are affected in the same way. We show that misalignment of the output ports of the interferometer (output misalignment) only affects the high-frequency part of the quantum-noise limited sensitivity (detection noise). However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise (back-action noise) by the same amount and hence the quantum-noise limited sensitivity is not negatively affected in that frequency range. We show that the misalignment of the laser into the interferometer (input misalignment) produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof-of-concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment.

  13. Microfluidic transmission surface plasmon resonance enhancement for biosensor applications

    NASA Astrophysics Data System (ADS)

    Lertvachirapaiboon, Chutiparn; Baba, Akira; Ekgasit, Sanong; Shinbo, Kazunari; Kato, Keizo; Kaneko, Futao

    2017-01-01

    The microfluidic transmission surface plasmon resonance (MTSPR) constructed by assembling a gold-coated grating substrate with a microchannel was employed for biosensor application. The transmission surface plasmon resonance spectrum obtained from the MTSPR sensor chip showed a strong and narrow surface plasmon resonance (SPR) peak located between 650 and 800 nm. The maximum SPR excitation was observed at an incident angle of 35°. The MTSPR sensor chip was employed for glucose sensor application. Gold-coated grating substrates were functionalized using 3-mercapto-1-propanesulfonic acid sodium salt and subsequently functionalized using a five-bilayer poly(allylamine hydrochloride)/poly(sodium 4-styrenesulfonate) to facilitate the coupling/decoupling of the surface plasmon and to prepare a uniform surface for sensing. The detection limit of our developed system for glucose was 2.31 mM. This practical platform represents a high possibility of further developing several biomolecules, multiplex systems, and a point-of-care assay for practical biosensor applications.

  14. Application of constrained deconvolution technique for reconstruction of electron bunch profile with strongly non-Gaussian shape

    NASA Astrophysics Data System (ADS)

    Geloni, G.; Saldin, E. L.; Schneidmiller, E. A.; Yurkov, M. V.

    2004-08-01

    An effective and practical technique based on the detection of the coherent synchrotron radiation (CSR) spectrum can be used to characterize the profile function of ultra-short bunches. The CSR spectrum measurement has an important limitation: no spectral phase information is available, and the complete profile function cannot be obtained in general. In this paper we propose to use constrained deconvolution method for bunch profile reconstruction based on a priori-known information about formation of the electron bunch. Application of the method is illustrated with practically important example of a bunch formed in a single bunch-compressor. Downstream of the bunch compressor the bunch charge distribution is strongly non-Gaussian with a narrow leading peak and a long tail. The longitudinal bunch distribution is derived by measuring the bunch tail constant with a streak camera and by using a priory available information about profile function.

  15. Assessment of the Utility of Cytology and Flow Cytometry of Cerebrospinal Fluid Samples in Clinical Practice.

    PubMed

    Nam, Anna S; Giorgadze, Tamara; Tam, Wayne; Chadburn, Amy

    2018-01-01

    We sought to assess the utility and limitations of both flow cytometry (FC) and cytology for the analysis of cerebrospinal fluid (CSF) in a practical clinical setting. A total of 393 consecutive CSF samples from 171 patients submitted for both cytomorphologic and FC assessments were analyzed. Both FC and cytology findings were negative for malignancy in 315/393 samples (80%), and either positive (POS) or suspicious/atypical (SUSP/AT) in 7% of samples. This resulted in high agreement between FC and cytology (87%). Minor discrepancies were present in 4% of the cases. In 28 samples, an abnormal population was detected by FC but not by cytology. FC and cytology are important complementary methods for analyzing CSF samples. In cases where cytology is SUSP/AT and FC is inconclusive or negative, additional specimens should be submitted for immunostaining, cytogenetics, and/or molecular studies. © 2018 S. Karger AG, Basel.

  16. Coping with domestic violence against children and adolescents from the perspective of primary care nurses.

    PubMed

    Leite, Jéssica Totti; Beserra, Maria Aparecida; Scatena, Liliana; Silva, Lygia Maria Pereira da; Ferriani, Maria das Graças Carvalho

    2016-06-01

    To analyse the actions reported by primary care nurses in the fight against domestic violence against children and adolescents. Qualitative research conducted at five family health centres in the state of São Paulo, Brazil. Data were collected in the second half of 2013 through semi-structured. Two thematic cores emerged: "Public policies identified by the nurses" and "Nurses' actions regarding violence permeated by fear and conflicts". The nurses were familiar with public policies, but they were unable to put them into practice; they were unprepared to identify and cope with the violence; they did not participate in training courses; they were afraid to report the detected cases of violence. The main limitations to the practical work of nurses are work burden, lack of security, and the dynamics of work that is not articulated with the protection network, which causes the underreporting of cases of domestic violence.

  17. Biosensors in Clinical Practice: Focus on Oncohematology

    PubMed Central

    Fracchiolla, Nicola S.; Artuso, Silvia; Cortelezzi, Agostino

    2013-01-01

    Biosensors are devices that are capable of detecting specific biological analytes and converting their presence or concentration into some electrical, thermal, optical or other signal that can be easily analysed. The first biosensor was designed by Clark and Lyons in 1962 as a means of measuring glucose. Since then, much progress has been made and the applications of biosensors are today potentially boundless. This review is limited to their clinical applications, particularly in the field of oncohematology. Biosensors have recently been developed in order to improve the diagnosis and treatment of patients affected by hematological malignancies, such as the biosensor for assessing the in vitro pre-treatment efficacy of cytarabine in acute myeloid leukemia, and the fluorescence resonance energy transfer-based biosensor for assessing the efficacy of imatinib in chronic myeloid leukemia. The review also considers the challenges and future perspectives of biosensors in clinical practice. PMID:23673681

  18. Triplex DNA formation-mediated strand displacement reaction for highly sensitive fluorescent detection of melamine.

    PubMed

    Liu, Xiaojuan; Xu, Ningning; Gai, Panpan; Li, Feng

    2018-08-01

    Since melamine is a strong hazard to human health, the development of new methods for highly sensitive detection of melamine is highly desirable. Herein, a novel fluorescent biosensing strategy was designed for sensitive and selective melamine assay based on the recognition ability of abasic (AP) site in triplex towards melamine and signal amplification by Mg 2+ -dependent DNAzyme. In this strategy, the melamine-induced formation of triplex DNA was employed to trigger the strand displacement reaction (SDR). The SDR process converted the specific target recognition into the release and activation of Mg 2+ -dependent DNAzyme, which could catalyze the cleavage of fluorophore/quencher labeled DNA substrate (FQ), resulting in a significantly increased fluorescent signal. Under the optimal conditions, the fluorescent signal has a linear relationship with the logarithm of the melamine concentration in a wide range of 0.005-50 μM. The detection limit was estimated to be 0.9 nM (0.1ppb), which is sufficiently sensitive for practical application. Furthermore, this strategy exhibits high selectivity against other potential interfering substances, and the practical application of this strategy for milk samples reveals that the proposed strategy works well for melamine assay in real samples. Therefore, this strategy presents a new method for the sensitive melamine assay and holds great promise for sensing applications in the environment and the food safety field. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Defining overweight and obesity among Greek children living in Thessaloniki: International versus local reference standards.

    PubMed

    Christoforidis, A; Dimitriadou, M; Papadopolou, E; Stilpnopoulou, D; Katzos, G; Athanassiou-Metaxa, M

    2011-04-01

    Body Mass Index (BMI) offers a simple and reasonable measure of obesity that, with the use of the appropriate reference, can help in the early detection of children with weight problems. Our aim was to compare the two most commonly used international BMI references and the national Greek BMI reference in identifying Greek children being overweight and obese. A group of 1557 children (820 girls and 737 boys, mean age: 11.42 ± 3.51 years) were studied. Weight and height was measured using standard methods, and BMI was calculated. Overweight and obesity were determined using the International Obesity Task Force (IOTF) standards, the Centers for Disease Control and Prevention (CDC) BMI-forage curves and the most recent Greek BMI-for-age curves. RESULTS showed that the IOTF's cut-off limits identifies a significantly higher prevalence of overweight (22.4%) compared with both the CDC's (11.8%, p=0.03) and the Greek's (7.4%, p=0.002) cut-off limits. However, the prevalence of obesity was generally increased when it was determined using the CDC's cut-off limits (13.9%) compared to the prevalence calculated with both the IOTF's (6.5%, p=0.05) and the Greek's (6.9%, n.s.) cut off limits. The use of the national Greek reference standards for BMI underestimates the true prevalence of overweight and obesity. On the contrary, both the IOTF and the CDC standards, although independently, detect an increased number of overweight and obese children and thus they should be adopted in the clinical practice for an earlier identification and a timelier intervention.

  20. Search times and probability of detection in time-limited search

    NASA Astrophysics Data System (ADS)

    Wilson, David; Devitt, Nicole; Maurer, Tana

    2005-05-01

    When modeling the search and target acquisition process, probability of detection as a function of time is important to war games and physical entity simulations. Recent US Army RDECOM CERDEC Night Vision and Electronics Sensor Directorate modeling of search and detection has focused on time-limited search. Developing the relationship between detection probability and time of search as a differential equation is explored. One of the parameters in the current formula for probability of detection in time-limited search corresponds to the mean time to detect in time-unlimited search. However, the mean time to detect in time-limited search is shorter than the mean time to detect in time-unlimited search and the relationship between them is a mathematical relationship between these two mean times. This simple relationship is derived.

  1. Shot noise limited detection of OH using the technique of laser induced fluorescence

    NASA Technical Reports Server (NTRS)

    Bakalyar, D. M.; Davis, L. I., Jr.; Guo, C.; James, J. V.; Kakos, S.; Morris, P. T.; Wang, C. C.

    1984-01-01

    Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

  2. Shot noise limited detection of OH using the technique of laser-induced fluorescence

    NASA Technical Reports Server (NTRS)

    Bakalyar, D. M.; Davis, L. I., Jr.; Guo, C.; James, J. V.; Wang, C. C.; Kakos, S.; Morris, P. T.

    1984-01-01

    Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

  3. Detecting the fingerprints of complex land management practices in a tallgrass prairie site using phenocam and satellite images, and the eddy covariance technique

    USDA-ARS?s Scientific Manuscript database

    Burning, grazing, and baling (hay harvesting) are common management practices for tallgrass prairie. However, the impacts of these management practices on grassland phenology and carbon uptake are not well understood. Utilizing multiple observations to detect fingerprints of various management pract...

  4. Determination of low ppm levels of dimethyl sulfate in an aqueous soluble API intermediate using liquid-liquid extraction and GC-MS.

    PubMed

    Zheng, Jie; Pritts, Wayne A; Zhang, Shuhong; Wittenberger, Steve

    2009-12-05

    Dimethyl sulfate (DMS) is an alkylating reagent commonly used in organic syntheses and pharmaceutical manufacturing processes. Due to its potential carcinogenicity, the level of DMS in the API process needs to be carefully monitored. However, in-process testing for DMS is challenging because of its reactivity and polarity as well as complex matrix effects. In this short communication, we report a GC-MS method for determination of DMS in an API intermediate that is a methyl sulfate salt. To overcome the complex matrix interference, DMS and an internal standard, d6-DMS, were extracted from the matrix with methyl tert-butyl ether. GC separation was conducted on a DB-624 column (30 m long, 0.32 mm ID, 1.8 microm film thickness). MS detection was performed on a single-quad Agilent MSD equipped with an electron impact source while the MSD signal was acquired in selected ion monitoring mode. This GC/MS method showed a linear response for DMS equivalent from 1.0 to 60 ppm. The practical quantitation limit for DMS was 1.0 ppm and the practical detection limit was 0.3 ppm. The relative standard derivation for analyte response was found as 0.1% for six injections of a working standard equivalent to 18.6 ppm of DMS. The spike recovery was ranged from 102.1 to 108.5% for a sample of API intermediate spiked with 8.0 ppm of DMS. In summary, the GC/MS method showed adequate specificity, linearity, sensitivity, repeatability and accuracy for determination of DMS in the API intermediate. This method has been successfully applied to study the efficiency of removing DMS from the process.

  5. Determination of low-level mercury in coralline aragonite by calcination-isotope dilution-inductively coupled plasma-mass spectrometry and its application to Diploria specimens from Castle Harbour, Bermuda

    NASA Astrophysics Data System (ADS)

    Lamborg, Carl H.; Swarr, Gretchen; Hughen, Konrad; Jones, Ross J.; Birdwhistell, Scot; Furby, Kathryn; Murty, Sujata A.; Prouty, Nancy; Tseng, Chun-Mao

    2013-05-01

    We have developed a technique that combines a high temperature quartz furnace with inductively coupled plasma-mass spectrometry for the determination of Hg stored in the annual CaCO3 bands found in coral skeletons. Substantial matrix effects, presumably due to the discontinuous introduction of CO2 to the gas stream, were corrected for by simultaneously supplying a stream of argon containing highly enriched elemental 202Hgo and observing peaks in the 200Hg/202Hg signal as the sample was decomposed. Primary signal calibration for Hg was achieved using gas injections from a saturated vapor standard. The absolute instrument detection limit was low (about 0.2 fmol), with a practical limit of detection (3σ of blanks) of 2 fmol. Reproducibility of samples was (RSD) 15-27%. We applied this method to the determination of Hg concentrations in two colonies of Diploria labyrinthiformis collected from Castle Harbour, Bermuda, at a site about to be buried under the municipal waste landfill. The temporal reconstructions of Castle Harbour seawater Hg concentrations implied by the coral record show a decline throughout the period of record (1949-2008). The coral archived no apparent signal associated with waste disposal practices in the Harbour (bulk waste land-filling or, since 1994, disposal of waste incinerator ash), and mercury concentrations in the coral did not correlate to growth rate as assessed by linear extension. There was, however, a large and nearly exponential decrease in apparent Hg concentration in the Harbour which circumstantially implicates the dredging and/or landfilling operations associated with the construction of the airport on St. David's Island.

  6. Review of the Methods to Obtain Paediatric Drug Safety Information: Spontaneous Reporting and Healthcare Databases, Active Surveillance Programmes, Systematic Reviews and Meta-analyses

    PubMed

    Gentili, Marta; Pozzi, Marco; Peeters, Gabrielle; Radice, Sonia; Carnovale, Carla

    2018-02-06

    Knowledge of drugs safety collected during the pre-marketing phase is inevitably limited because the randomized clinical trials (RCTs) are rarely designed to evaluate safety. The small and selective groups of enrolled individuals and the limited duration of trials may hamper the ability to characterize fully the safety profiles of drugs. Additionally, information about rare adverse drug reactions (ADRs) in special groups is often incomplete or not available for most of the drugs commonly used in the daily clinical practice. In the paediatric setting several highimpact safety issues have emerged. Hence, in recent years, there has been a call for improved post-marketing pharmacoepidemiological studies, in which cohorts of patients are monitored for sufficient time in order to determine the precise risk-benefit ratio. In this review, we discuss the current available strategies enhancing the post-marketing monitoring activities of the drugs in the paediatric setting and define criteria whereby they can provide valuable information to improve the management of therapy in daily clinical practice including both safety and efficacy aspects. The strategies we cover include the signal detection using international pharmacovigilance and/or healthcare databases, the promotion of active surveillance initiatives which can generate complete, informative data sets for the signal detection and systematic review/meta-analysis. Together, these methods provide a comprehensive picture of causality and risk improving the management of therapy in a paediatric setting and they should be considered as a unique tool to be integrated with post-marketing activities. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Point-of-care cardiac ultrasound techniques in the physical examination: better at the bedside.

    PubMed

    Kimura, Bruce J

    2017-07-01

    The development of hand-carried, battery-powered ultrasound devices has created a new practice in ultrasound diagnostic imaging, called 'point-of-care' ultrasound (POCUS). Capitalising on device portability, POCUS is marked by brief and limited ultrasound imaging performed by the physician at the bedside to increase diagnostic accuracy and expediency. The natural evolution of POCUS techniques in general medicine, particularly with pocket-sized devices, may be in the development of a basic ultrasound examination similar to the use of the binaural stethoscope. This paper will specifically review how POCUS improves the limited sensitivity of the current practice of traditional cardiac physical examination by both cardiologists and non-cardiologists. Signs of left ventricular systolic dysfunction, left atrial enlargement, lung congestion and elevated central venous pressures are often missed by physical techniques but can be easily detected by POCUS and have prognostic and treatment implications. Creating a general set of repetitive imaging skills for these entities for application on all patients during routine examination will standardise and reduce heterogeneity in cardiac bedside ultrasound applications, simplify teaching curricula, enhance learning and recollection, and unify competency thresholds and practice. The addition of POCUS to standard physical examination techniques in cardiovascular medicine will result in an ultrasound-augmented cardiac physical examination that reaffirms the value of bedside diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Breast cancer mammographic diagnosis performance in a public health institution: a retrospective cohort study.

    PubMed

    Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S

    2017-12-01

    To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.

  9. Symbol Synchronization for Diffusion-Based Molecular Communications.

    PubMed

    Jamali, Vahid; Ahmadzadeh, Arman; Schober, Robert

    2017-12-01

    Symbol synchronization refers to the estimation of the start of a symbol interval and is needed for reliable detection. In this paper, we develop several symbol synchronization schemes for molecular communication (MC) systems where we consider some practical challenges, which have not been addressed in the literature yet. In particular, we take into account that in MC systems, the transmitter may not be equipped with an internal clock and may not be able to emit molecules with a fixed release frequency. Such restrictions hold for practical nanotransmitters, e.g., modified cells, where the lengths of the symbol intervals may vary due to the inherent randomness in the availability of food and energy for molecule generation, the process for molecule production, and the release process. To address this issue, we develop two synchronization-detection frameworks which both employ two types of molecule. In the first framework, one type of molecule is used for symbol synchronization and the other one is used for data detection, whereas in the second framework, both types of molecule are used for joint symbol synchronization and data detection. For both frameworks, we first derive the optimal maximum likelihood (ML) symbol synchronization schemes as performance upper bounds. Since ML synchronization entails high complexity, for each framework, we also propose three low-complexity suboptimal schemes, namely a linear filter-based scheme, a peak observation-based scheme, and a threshold-trigger scheme, which are suitable for MC systems with limited computational capabilities. Furthermore, we study the relative complexity and the constraints associated with the proposed schemes and the impact of the insertion and deletion errors that arise due to imperfect synchronization. Our simulation results reveal the effectiveness of the proposed synchronization schemes and suggest that the end-to-end performance of MC systems significantly depends on the accuracy of the symbol synchronization.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinclair, Karin; DeGeorge, Elise

    The Bald and Golden Eagle Protection Act (BGEPA) prohibits the 'take' of these birds. The act defines take as to 'pursue, shoot, shoot at, poison, wound, kill, capture, trap, collect, destroy, molest or disturb.' The 2009 Eagle Permit Rule (74 FR 46836) authorizes the U.S. Fish and Wildlife Service (USFWS) to issue nonpurposeful (i.e., incidental) take permits, and the USFWS 2013 Eagle Conservation Plan Guidance provides a voluntary framework for issuing programmatic take permits to wind facilities that incorporate scientifically supportable advanced conservation practices (ACPs). Under these rules, the Service can issue permits that authorize individual instances of take ofmore » bald and golden eagles when the take is associated with, but not the purpose of, an otherwise lawful activity, and cannot practicably be avoided. To date, the USFWS has not approved any ACPs, citing the lack of evidence for 'scientifically supportable measures.' The Eagle Detection and Deterrents Research Gaps and Solutions Workshop was convened at the National Renewable Energy Laboratory in December 2015 with a goal to comprehensively assess the current state of technologies to detect and deter eagles from wind energy sites and the key gaps concerning reducing eagle fatalities and facilitating permitting under the BGEPA. During the workshop, presentations and discussions focused primarily on existing knowledge (and limitations) about the biology of eagles as well as technologies and emerging or novel ideas, including innovative applications of tools developed for use in other sectors, such as the U.S. Department of Defense and aviation. The main activity of the workshop was the breakout sessions, which focused on the current state of detection and deterrent technologies and novel concepts/applications for detecting and minimizing eagle collisions with wind turbines. Following the breakout sessions, participants were asked about their individual impressions of the relative priority of each of the existing and novel ideas.« less

  11. A method for detecting fungal contaminants in wall cavities.

    PubMed

    Spurgeon, Joe C

    2003-01-01

    This article describes a practical method for detecting the presence of both fungal spores and culturable fungi in wall cavities. Culturable fungi were collected in 25 mm cassettes containing 0.8 microm mixed cellulose ester filters using aggressive sampling conditions. Both culturable fungi and fungal spores were collected in modified slotted-disk cassettes. The sample volume was 4 L. The filters were examined microscopically and dilution plated onto multiple culture media. Collecting airborne samples in filter cassettes was an effective method for assessing wall cavities for fungal contaminants, especially because this method allowed the sample to be analyzed by both microscopy and culture media. Assessment criteria were developed that allowed the sample results to be used to classify wall cavities as either uncontaminated or contaminated. As a criterion, wall cavities with concentrations of culturable fungi below the limit of detection (LOD) were classified as uncontaminated, whereas those cavities with detectable concentrations of culturable fungi were classified as contaminated. A total of 150 wall cavities was sampled as part of a field project. The concentrations of culturable fungi were below the LOD in 34% of the samples, whereas Aspergillus and/or Penicillium were the only fungal genera detected in 69% of the samples in which culturable fungi were detected. Spore counting resulted in the detection of Stachybotrys-like spores in 25% of the samples that were analyzed, whereas Stachybotrys chartarum colonies were only detected on 2% of malt extract agar plates and on 6% of corn meal agar plates.

  12. Olfactory dysfunction and its measurement in the clinic and workplace.

    PubMed

    Doty, Richard L

    2006-04-01

    To provide an overview of practical means for quantitatively assessing the sense of smell in both the clinic and workplace. To address basic measurement issues, including those of test sensitivity, specificity, and reliability. To describe and discuss factors that influence olfactory function, including airborne toxins commonly found in industrial settings. Selective review and discussion. A number of well-validated practical threshold and suprathreshold tests are available for assessing smell function. The reliability, sensitivity, and specificity of such techniques vary, being influenced by such factors as test length and type. Numerous subject factors, including age, sex, health, medications, and exposure to environmental toxins, particularly heavy metals, influence the ability to smell. Modern advances in technology, in conjunction with better occupational medicine practices, now make it possible to reliably monitor and limit occupational exposures to hazardous chemicals and their potential adverse influences on the sense of smell. Quantitative olfactory testing is critical to establish the presence or absence of such adverse influences, as well as to (a) detect malingering, (b) establish disability compensation, and (c) monitor function over time.

  13. A novel conductance glucose biosensor in ultra-low ionic strength solution triggered by the oxidation of Ag nanoparticles.

    PubMed

    Song, Yonghai; Chen, Jingyi; Liu, Hongyu; Li, Ping; Li, Hongbo; Wang, Li

    2015-09-03

    A simple, sensitive and effective method to detect glucose in ultra-low ionic strength solution containing citrate-capped silver nanoparticles (CCAgNPs) was developed by monitoring the change of solution conductance. Glucose was catalyzed into gluconic acid firstly by glucose oxidase in an O2-saturated solution accompanied by the reduction of O2 into hydrogen peroxide (H2O2). Then, CCAgNPs was oxidized by H2O2 into Ag(+) and the capping regent of citrate was released at the same time. All these resulted Ag(+), gluconic acid and the released citrate would contribute to the increase of solution ionic strength together, leading to a detectable increase of solution conductance. And a novel conductance glucose biosensor was developed with a routine linear range of 0.06-4.0 mM and a suitable detection limit of 18.0 μM. The novel glucose biosensor was further applied in energy drink sample and proven to be suitable for practical system with low ionic strength. The proposed conductance biosensor achieved a significant breakthrough of glucose detection in ultra-low ionic strength media. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Algorithms for detection of objects in image sequences captured from an airborne imaging system

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Camps, Octavia; Tang, Yuan-Liang; Devadiga, Sadashiva; Gandhi, Tarak

    1995-01-01

    This research was initiated as a part of the effort at the NASA Ames Research Center to design a computer vision based system that can enhance the safety of navigation by aiding the pilots in detecting various obstacles on the runway during critical section of the flight such as a landing maneuver. The primary goal is the development of algorithms for detection of moving objects from a sequence of images obtained from an on-board video camera. Image regions corresponding to the independently moving objects are segmented from the background by applying constraint filtering on the optical flow computed from the initial few frames of the sequence. These detected regions are tracked over subsequent frames using a model based tracking algorithm. Position and velocity of the moving objects in the world coordinate is estimated using an extended Kalman filter. The algorithms are tested using the NASA line image sequence with six static trucks and a simulated moving truck and experimental results are described. Various limitations of the currently implemented version of the above algorithm are identified and possible solutions to build a practical working system are investigated.

  15. Development of a robust chromatographic method for the detection of chlorophenols in cork oak forest soils.

    PubMed

    McLellan, Iain; Hursthouse, Andrew; Morrison, Calum; Varela, Adélia; Pereira, Cristina Silva

    2014-02-01

    A major concern for the cork and wine industry is 'cork taint' which is associated with chloroanisoles, the microbial degradation metabolites of chlorophenols. The use of chlorophenolic compounds as pesticides within cork forests was prohibited in 1993 in the European Union (EU) following the introduction of industry guidance. However, cork produced outside the EU is still thought to be affected and simple, robust methods for chlorophenol analysis are required for wider environmental assessment by industry and local environmental regulators. Soil samples were collected from three common-use forests in Tunisia and from one privately owned forest in Sardinia, providing examples of varied management practice and degree of human intervention. These provided challenge samples for the optimisation of a HPLC-UV detection method. It produced recoveries consistently >75% against a soil CRM (ERM-CC008) for pentachlorophenol. The optimised method, with ultraviolet (diode array) detection is able to separate and quantify 16 different chlorophenols at field concentrations greater than the limits of detection ranging from 6.5 to 191.3 μg/kg (dry weight). Application to a range of field samples demonstrated the absence of widespread contamination in forest soils at sites sampled in Sardinia and Tunisia.

  16. A portable synthesis of water-soluble carbon dots for highly sensitive and selective detection of chlorogenic acid based on inner filter effect

    NASA Astrophysics Data System (ADS)

    Yang, Huan; Yang, Liu; Yuan, Yusheng; Pan, Shuang; Yang, Jidong; Yan, Jingjing; Zhang, Hui; Sun, Qianqian; Hu, Xiaoli

    2018-01-01

    In this work, a simple and facile hydrothermal method for synthesis of water-soluble carbon dots (CDs) with malic acid and urea, and were then employed as a high-performance fluorescent probe for selective and sensitive determination of chlorogenic acid (CGA) based on inner filter effect. The as-synthesized CDs was systematically characterized by Transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), Energy disperse spectroscopy (EDS), UV-vis absorption spectroscopy, spectrofluorophotometry, and the results indicated that the sizes of CDs were mainly distributed in the range of 1.0 nm-3.0 nm with an average diameter of 2.1 nm. More significantly, the as-prepared CDs possessed remarkable selectivity and sensitivity towards CGA with the linear range of 0.15 μmol L- 1-60 μmol L- 1 and the detection limit for CGA was 45 nmol L- 1 (3σ/k). The practical applications of CDs for detection of CGA have already been successfully demonstrated in Honeysuckle. This sensitive, selective method has a great application prospect in the pharmaceutical and biological analysis field owing to its simplicity and rapidity for the detection of CGA.

  17. A proof of concept study to assess the potential of PCR testing to detect natural Mycobacterium bovis infection in South American camelids

    PubMed Central

    2014-01-01

    Background Cases of Mycobacterium bovis infection South American camelids have been increasing in Great Britain. Current antemortem immunological tests have some limitations. Cases at post mortem examination frequently show extensive pathology. The feasibility of detecting Mycobacterium bovis DNA in clinical samples was investigated. Findings A sensitive extraction methodology was developed and used on nasal swabs and faeces taken post-mortem to assess the potential for a PCR test to detect Mycobacterium bovis in clinical samples. The gross pathology of the studied South American camelids was scored and a significantly greater proportion of South American camelids with more severe pathology were positive in both the nasal swab and faecal PCR tests. A combination of the nasal swab and faecal PCR tests detected 63.9% of all the South American camelids with pathology that were tested. Conclusions The results suggest that antemortem diagnosis of Mycobacterium bovis in South American camelids may be possible using a PCR test on clinical samples, however more work is required to determine sensitivity and specificity, and the practicalities of applying the test in the field. PMID:24507471

  18. A Cyanine Dye Encapsulated Porous Fibrous Mat for Naked-Eye Ammonia Sensing.

    PubMed

    Ji, Chendong; Ma, Lijing; Yin, Meizhen; Yang, Wantai; Pan, Kai

    2016-08-19

    Electrospun ultrathin fiber-based sensors are desirable because of their practicality and sensitivity. Ammonia-detection systems are in high demand in different areas, including the industrial and agricultural fields. However, current technologies rely on large and complex instruments that restrict their actual utilization. Herein, we report a flexible naked-eye ammonia sensor, the polylactic acid-cyanine (PLA-Cy) fibrous mat, which was fabricated by blending a carboxyl-functionalized cyanine dye (D1) into electospun PLA porous fibers. The sensing mat was shown to undergo a naked-eye-detectable color change from white to blue upon exposure to ammonia vapor. The mat showed high selectivity to ammonia gas with a detection limit of 3.3 ppm. Aggregated D1 was first encapsulated by PLA and was then ionized by NH3 . These mechanisms were examined by photophysical studies and scanning electron microscopy. The aggregation-deaggregation process of D1 in the PLA-Cy fibrous mat led to the color change. This work provides a facile method for the naked-eye detection of ammonia and a novel strategy for the use of organic dyes in ammonia sensing. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Military applications and examples of near-surface seismic surface wave methods (Invited)

    NASA Astrophysics Data System (ADS)

    sloan, S.; Stevens, R.

    2013-12-01

    Although not always widely known or publicized, the military uses a variety of geophysical methods for a wide range of applications--some that are already common practice in the industry while others are truly novel. Some of those applications include unexploded ordnance detection, general site characterization, anomaly detection, countering improvised explosive devices (IEDs), and security monitoring, to name a few. Techniques used may include, but are not limited to, ground penetrating radar, seismic, electrical, gravity, and electromagnetic methods. Seismic methods employed include surface wave analysis, refraction tomography, and high-resolution reflection methods. Although the military employs geophysical methods, that does not necessarily mean that those methods enable or support combat operations--often times they are being used for humanitarian applications within the military's area of operations to support local populations. The work presented here will focus on the applied use of seismic surface wave methods, including multichannel analysis of surface waves (MASW) and backscattered surface waves, often in conjunction with other methods such as refraction tomography or body-wave diffraction analysis. Multiple field examples will be shown, including explosives testing, tunnel detection, pre-construction site characterization, and cavity detection.

  20. Manipulating the Surface Chemistry of Quantum Dots for Sensitive Ratiometric Fluorescence Detection of Sulfur Dioxide.

    PubMed

    Li, Huihui; Zhu, Houjuan; Sun, Mingtai; Yan, Yehan; Zhang, Kui; Huang, Dejian; Wang, Suhua

    2015-08-11

    Herein, we report a novel approach to the rapid visual detection of gaseous sulfur dioxide (SO2) by manipulating the surface chemistry of 3-aminopropyltriethoxysilane (APTS)-modified quantum dots (QDs) using fluorescent coumarin-3-carboxylic acid (CCA) for specific reaction with SO2. The CCA molecules are attached to the surface amino groups of the QDs through electrostatic attraction, thus the fluorescence of CCA is greatly suppressed because of the formation of an ion-pair complex between the ATPS-modified QDs and CCA. Such an interaction is vulnerable to SO2 because SO2 can readily react with surface amino groups to form strong charge-transfer complexes and subsequently release the strongly fluorescent CCA molecules. The mechanism has been carefully verified through a series of control experiments. Upon exposure to different amounts of SO2, the fluorescent color of the nanoparticle-based sensor displays continuously changes from red to blue. Most importantly, the approach owns high selectivity for SO2 and a tolerance of interference, which enables the sensor to detect SO2 in a practical application. Using this fluorescence-based sensing method, we have achieved a visual detection limit of 6 ppb for gaseous SO2.

Top