Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.
van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina
2017-12-13
Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Ultrasound-guided thermocouple placement for cryosurgery.
Abramovits, W; Pruiksma, R; Bose, S
1996-09-01
Although cryosurgical methods have high cure rates, imprecise estimates of both skin lesion depth and destructive temperature front location result in subjective technique in skin malignancy treatments. We evaluated the possibility of newer ultrasound equipment to assist in the precise placement of thermocouples in human skin. DermaScan C ver. 3 ultrasonographic equipment fitted with a sharp focus probe with a frequency of 20 MHz and a scan length of 12.1 mm was used to locate thermocouples with 27- and 30-gauge needles. We successfully and reproducibly located thermocouples and thin needles, and accurately measured their distance from the skin surface. Ultrasound is a useful method for the accurate placement of thermocouples, and needles as thin as 30 gauge for monitoring in cryosurgery.
Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions
Seifabadi, Reza; Iordachita, Iulian; Fichtinger, Gabor
2013-01-01
Accurate needle placement plays a key role in success of prostate biopsy and brachytherapy. During percutaneous interventions, the prostate gland rotates and deforms which may cause significant target displacement. In these cases straight needle trajectory is not sufficient for precise targeting. Although needle spinning and fast insertion may be helpful, they do not entirely resolve the issue. We propose robot-assisted bevel-tip needle steering under MRI guidance as a potential solution to compensate for the target displacement. MRI is chosen for its superior soft tissue contrast in prostate imaging. Due to the confined workspace of the MRI scanner and the requirement for the clinician to be present inside the MRI room during the procedure, we designed a MRI-compatible 2-DOF haptic device to command the needle steering slave robot which operates inside the scanner. The needle steering slave robot was designed to be integrated with a previously developed pneumatically actuated transperineal robot for MRI-guided prostate needle placement. We describe design challenges and present the conceptual design of the master and slave robots and the associated controller. PMID:24649480
Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy
Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.
2014-01-01
This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962
Anderson, T. Anthony; Kang, Jeon Woong; Gubin, Tatyana; Dasari, Ramachandra R.; So, Peter T. C.
2016-01-01
BACKGROUND Neuraxial anesthesia and epidural steroid injection techniques require precise anatomical targeting to ensure successful and safe analgesia. Previous studies suggest that only some of the tissues encountered during these procedures can be identified by spectroscopic methods, and no previous study has investigated the use of Raman, diffuse reflectance, and fluorescence spectroscopies. The authors hypothesized that real-time needle-tip spectroscopy may aid epidural needle placement and tested the ability of spectroscopy to distinguish each of the tissues in the path of neuraxial needles. METHODS For comparison of detection methods, the spectra of individual, dissected ex vivo paravertebral and neuraxial porcine tissues were collected using Raman spectroscopy (RS), diffuse reflectance spectroscopy (DRS), and fluorescence spectroscopy (FS). Real-time spectral guidance was tested using a 2 mm inner diameter fiber optic probe-in-needle device. Raman spectra were collected during the needle’s passage through intact paravertebral and neuraxial porcine tissue and analyzed afterward. The RS tissue signatures were verified as mapping to individual tissue layers using histochemical staining and widefield microscopy. RESULTS Raman spectroscopy revealed a unique spectrum for all ex vivo paravertebral and neuraxial tissue layers; DRS and FS spectra were not distinct for all tissues. Moreover, when accounting for the expected order of tissues, real-time Raman spectra recorded during needle insertion also permitted identification of each paravertebral and neuraxial porcine tissue. CONCLUSIONS This study demonstrates Raman spectroscopy can distinguish the tissues encountered during epidural needle insertion. This technology may prove useful during needle placement by providing evidence of its anatomical localization. PMID:27466032
Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C
2007-09-01
To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.
Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.
Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D
2001-10-01
The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
Bond, L; Schulz, B; VanMeter, T; Martin, R C G
2017-02-01
Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Browne, Ingrid M; Birnbach, David J; Stein, Deborah J; O'Gorman, David A; Kuroda, Maxine
2005-08-01
When using the needle-through-needle combined spinal-epidural (CSE) technique for labor analgesia, failure to obtain cerebrospinal fluid (CSF), paresthesias, and intrathecal or intravascular migration of the catheter are of concern. Epidural needles with spinal needle apertures, such as the back-hole Espocan (ES) needles, are available and may reduce these risks. We describe the efficacy and adverse events associated with a modified epidural needle (ES) versus a conventional Tuohy needle for CSE. One-hundred parturients requesting labor analgesia (CSE) were randomized into 2 groups: 50-ES 18-gauge modified epidural needle with 27-gauge Pencan atraumatic spinal needle, 50-conventional 18-gauge Tuohy needle with 27-gauge Gertie Marx atraumatic spinal needle. Information on intrathecal or intravascular catheter placement, paresthesia on introduction of spinal needle, failure to obtain CSF through the spinal needle after placement of epidural needle, unintentional dural puncture, and epidural catheter function was obtained. No intrathecal catheter placement occurred in either group. Rates of intravascular catheter placement and unintentional dural puncture were similar between the groups. Significant differences were noted regarding spinal needle-induced paresthesia (14% ES versus 42% Tuohy needles, P = 0.009) and failure to obtain CSF on first attempt (8% ES versus 28% Tuohy needles, P < 0.02). Use of ES needles for CSE significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt. The use of modified epidural needles with a back hole for combined spinal-epidural technique significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt.
Augmented Reality-Guided Lumbar Facet Joint Injections.
Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda
2018-05-08
The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.
Van Buyten, Jean-Pierre; Smet, Iris; Van de Kelft, Erik
2009-07-01
Introduction. Interventional pain management techniques require precise positioning of needles or electrodes, therefore fluoroscopic control is mandatory. This imaging technique does however not visualize soft tissues such as blood vessels. Moreover, patient and physician are exposed to a considerable dose of radiation. Computed tomography (CT)-scans give a better view of soft tissues, but there use requires presence of a radiologist and has proven to be laborious and time consuming. Objectives. This study is to develop a technique using electromagnetic (EM) navigation as a guidance technique for interventional pain management, using CT and/or magnetic resonance (MRI) images uploaded on the navigation station. Methods. One of the best documented interventional procedures for the management of trigeminal neuralgia is percutaneous radiofrequency treatment of the Gasserian ganglion. EM navigation software for intracranial applications already exists. We developed a technique using a stylet with two magnetic coils suitable for EM navigation. The procedure is followed in real time on a computer screen where the patient's multislice CT-scan images and three-dimensional reconstruction of his face are uploaded. Virtual landmarks on the screen are matched with those on the patient's face, calculating the precision of the needle placement. Discussion. The experience with EM navigation acquired with the radiofrequency technique can be transferred to other interventional pain management techniques, for instance, for the placement of a neuromodulation electrode close to the Gasserian ganglion. Currently, research is ongoing to extend the software of the navigation station for spinal application, and to adapt neurostimulation hardware to the EM navigation technology. This technology will allow neuromodulation techniques to be performed without x-ray exposure for the patient and the physician, and this with the precision of CT/MR imaging guidance. © 2009 International Neuromodulation Society.
Endoscopic placement of Jones lacrimal tubes with the assistance of holmium YAG laser.
Boboridis, Kostas G; Downes, Richard N
2005-06-01
The aim of this paper is to highlight the use of the Holmium YAG laser in the endoscopic placement of Lester Jones tubes in patients with a blocked canaliculus or failed lacrimal pump function. Sixteen cases with a non-functional canaliculus were included over a one-year period. Following caruncle excision, a 19 G needle is inserted through the medial canthal tissues into the nasal space. Nasal endoscopy confirms the accurate positioning in relation to the nasal anatomy. With the Holmium YAG laser, a tissue channel is fashioned around the guide needle through the structures of the lateral nasal wall to facilitate an accurate and secure placement of the Jones tube. The endoscopic, laser-assisted placement reduces the operating time to less than 20 minutes, minimizes tissue trauma and does not require the initial surgical steps of an open DCR procedure. There were 14 cases (87.5%) with securely retained tubes and two cases (12.5%) that required tube replacement. The advantage of the procedure is especially great in revision surgery where the ostium is opened through scar tissue. Nasal endoscopy with the assistance of the Holmium YAG laser offers simplicity and precision in the placement of Jones tubes. It minimizes tissue trauma and increases the surgical success rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornelis, F.; Takaki, H.; Laskhmanan, M.
PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less
Sinskey, Jina L; Vecchione, Tricia M; Ekstrom, Benjamin G; Boretsky, Karen
2018-06-01
Pediatric caudal epidural blockade, the most common pediatric regional anesthetic, is classically placed using surface landmark technique with infrequent use of ultrasound guidance. We present 3 cases where ultrasound guidance facilitated successful placement and helped prevent complications. One infant had an unanticipated S5 dural sac necessitating needle redirection to avoid subarachnoid injection. A 5-year old had proper needle position with inability to inject secondary to needle blockage confirmed with ultrasound. An expremature infant had initial needle placement anterior to the sacrum with subsequent proper placement using real-time ultrasound imaging. Ultrasound guidance for pediatric caudal placement confers advantages and increased routine use should be considered.
Nonpalpable breast tumors: diagnosis with stereotaxic localization and fine-needle aspiration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowlatshahi, K.; Gent, H.J.; Schmidt, R.
1989-02-01
Modern mammography is the most effective means of detecting nonpalpable breast cancers, but correct diagnosis for malignancy is made in only 20%-30% of the cases. The conventional method of lesion localization usually results in approximate placement of the hookwire in the breast. The authors report the results of stereotaxic localization, combined with fine-needle aspiration and cytologic study, performed in 528 cases. Clinically occult breast lesions were localized precisely (within 2 mm 96% of the time), sampled by means of a 23-gauge needle, and marked with either methylene blue or a hookwire for subsequent open excisional biopsy. The results indicate amore » sensitivity of 95%, specificity of 91%, and accuracy of 92% for the fine-needle aspiration procedure. This technique offers a significantly improved preoperative method of diagnosing small breast lesions with minimal pain, no complications, reduced cost, and no disfigurement or scar interfering with subsequent mammographic follow-up.« less
Percutaneous spinal fixation simulation with virtual reality and haptics.
Luciano, Cristian J; Banerjee, P Pat; Sorenson, Jeffery M; Foley, Kevin T; Ansari, Sameer A; Rizzi, Silvio; Germanwala, Anand V; Kranzler, Leonard; Chittiboina, Prashant; Roitberg, Ben Z
2013-01-01
In this study, we evaluated the use of a part-task simulator with 3-dimensional and haptic feedback as a training tool for percutaneous spinal needle placement. To evaluate the learning effectiveness in terms of entry point/target point accuracy of percutaneous spinal needle placement on a high-performance augmented-reality and haptic technology workstation with the ability to control the duration of computer-simulated fluoroscopic exposure, thereby simulating an actual situation. Sixty-three fellows and residents performed needle placement on the simulator. A virtual needle was percutaneously inserted into a virtual patient's thoracic spine derived from an actual patient computed tomography data set. Ten of 126 needle placement attempts by 63 participants ended in failure for a failure rate of 7.93%. From all 126 needle insertions, the average error (15.69 vs 13.91), average fluoroscopy exposure (4.6 vs 3.92), and average individual performance score (32.39 vs 30.71) improved from the first to the second attempt. Performance accuracy yielded P = .04 from a 2-sample t test in which the rejected null hypothesis assumes no improvement in performance accuracy from the first to second attempt in the test session. The experiments showed evidence (P = .04) of performance accuracy improvement from the first to the second percutaneous needle placement attempt. This result, combined with previous learning retention and/or face validity results of using the simulator for open thoracic pedicle screw placement and ventriculostomy catheter placement, supports the efficacy of augmented reality and haptics simulation as a learning tool.
MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system
NASA Astrophysics Data System (ADS)
Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron
2014-03-01
Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.
Fredrickson, Michael J
2008-01-01
Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of =2 (scale, 0-10). In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
Hodges, P W; Kippers, V; Richardson, C A
1997-01-01
Fine-wire electromyography is primarily utilised for the recording of activity of the deep musculature, however, due to the location of these muscles, accurate electrode placement is difficult. Real-time ultrasound imaging (RTUI) of muscle tissue has been used for the guidance of the needle insertion for the placement of electrodes into the muscles of the abdominal wall. The validity of RTUI guidance of needle insertion into the deep muscles has not been determined. A cadaveric study was conducted to evaluate the accuracy with which RTUI can be used to guide fine-wire electrode placement using the posterior fibres of gluteus medius (PGM) as an example. Pilot studies revealed that the ultrasound resolution of cadaveric tissue is markedly reduced making it impossible to directly evaluate the technique, therefore, three studies were conducted. An initial study involved the demarcation of the anatomical boundaries of PGM using RTUI to define a technique based on an anatomical landmark that was consisent with the in vivo RTUI guided needle placement technique. This anatomical landmark was then used as the guide for the cadaveric needle insertion. Once the needle was positioned 0.05 ml of dye was introduced and the specimen dissected. The dye was accurately placed in PGM in 100% of the specimens. Finally, fine-wire electrodes were inserted into the PGM of five volunteers and manoeuvres performed indicating the accuracy of placement. This study supports the use of ultrasound imaging for the accurate guidance of needle insertion for fine-wire and needle EMG electrodes.
Manchikanti, Laxmaiah; Cash, Kim A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D
2004-04-01
Transforaminal epidural steroid injection is one of the commonly employed modalities of treatment in managing nerve root pain. However, there have been no controlled prospective evaluations of epidural and nerve root contrast distribution patterns and other aspects of fluoroscopically directed lumbosacral transforaminal epidural steroid injections. To evaluate contrast flow patterns and intravascular needle placement of fluoroscopically guided lumbosacral transforaminal epidural injections. A prospective, observational study. A total of 100 consecutive patients undergoing fluoroscopically guided transforaminal epidural steroid injections were evaluated. The contrast flow patterns, ventral or dorsal epidural filling, nerve root filling, C-arm time, and intravascular needle placement were evaluated. Ventral epidural filling was seen in 88% of the procedures, in contrast to dorsal filling noted in 9% of the procedures. Nerve root filling was seen in 97% of the procedures. Total intravenous placement of the needle was noted in 22% of the procedures, whereas negative flashback and aspiration was noted in 5% of the procedures. Lumbosacral transforaminal epidural injections, performed under fluoroscopic visualization, provide excellent nerve root filling and ventral epidural filling patterns. However, unrecognized intravascular needle placement with negative flashback or aspiration was noted in 5% of the procedures.
Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cepek, Jeremy, E-mail: jcepek@robarts.ca; Fenster, Aaron; Lindner, Uri
2014-01-15
Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table ismore » provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.« less
Accuracy Study of a Robotic System for MRI-guided Prostate Needle Placement
Seifabadi, Reza; Cho, Nathan BJ.; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fichtinger, Gabor; Iordachita, Iulian
2013-01-01
Background Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified, and minimized to the possible extent. Methods and Materials The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called before-insertion error) and the error associated with needle-tissue interaction (called due-to-insertion error). The before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator’s error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator’s accuracy and repeatability was also studied. Results The average overall system error in phantom study was 2.5 mm (STD=1.1mm). The average robotic system error in super soft phantom was 1.3 mm (STD=0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was approximated to be 2.13 mm thus having larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator’s targeting accuracy was 0.71 mm (STD=0.21mm) after robot calibration. The robot’s repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot’s accuracy and repeatability. Conclusions The experimental methodology presented in this paper may help researchers to identify, quantify, and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analyzed here, the overall error of the studied system remained within the acceptable range. PMID:22678990
Accuracy study of a robotic system for MRI-guided prostate needle placement.
Seifabadi, Reza; Cho, Nathan B J; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M; Fichtinger, Gabor; Iordachita, Iulian
2013-09-01
Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified and minimized to the possible extent. The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called 'before-insertion error') and the error associated with needle-tissue interaction (called 'due-to-insertion error'). Before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator's error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator's accuracy and repeatability was also studied. The average overall system error in the phantom study was 2.5 mm (STD = 1.1 mm). The average robotic system error in the Super Soft plastic phantom was 1.3 mm (STD = 0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was found to be approximately 2.13 mm, thus making a larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator's targeting accuracy was 0.71 mm (STD = 0.21 mm) after robot calibration. The robot's repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot's accuracy and repeatability. The experimental methodology presented in this paper may help researchers to identify, quantify and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analysed here, the overall error of the studied system remained within the acceptable range. Copyright © 2012 John Wiley & Sons, Ltd.
Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?
Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M
2009-01-01
Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.
Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S; Iordachita, Iulian I; Seifabadi, Reza; Cho, Nathan B; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M; Hata, Nobuhiko
2012-11-01
To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle toward a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between -5.7° and 5.7° horizontally and between -5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5mm along the horizontal axis and 0.8 ± 0.8mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4mm. Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study.
NASA Astrophysics Data System (ADS)
Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron
2017-03-01
Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.
Characterization of optically actuated MRI-compatible active needles for medical interventions
NASA Astrophysics Data System (ADS)
Black, Richard J.; Ryu, Seokchang; Moslehi, Behzad; Costa, Joannes M.
2014-03-01
The development of a Magnetic Resonance Imaging (MRI) compatible optically-actuated active needle for guided percutaneous surgery and biopsy procedures is described. Electrically passive MRI-compatible actuation in the small diameter needle is provided by non-magnetic materials including a shape memory alloy (SMA) subject to precise fiber laser operation that can be from a remote (e.g., MRI control room) location. Characterization and optimization of the needle is facilitated using optical fiber Bragg grating (FBG) temperature sensors arrays. Active bending of the needle during insertion allows the needle to be accurately guided to even relatively small targets in an organ while avoiding obstacles and overcoming undesirable deviations away from the planned path due to unforeseen or unknowable tissue interactions. This feature makes the needle especially suitable for use in image-guided surgical procedures (ranging from MRI to CT and ultrasound) when accurate targeting is imperative for good treatment outcomes. Such interventions include reaching small tumors in biopsies, delineating freezing areas in, for example, cryosurgery and improving the accuracy of seed placement in brachytherapy. Particularly relevant are prostate procedures, which may be subject to pubic arch interference. Combining diagnostic imaging and actuation assisted biopsy into one treatment can obviate the need for a second exam for guided biopsy, shorten overall procedure times (thus increasing operating room efficiencies), address healthcare reimbursement constraints and, most importantly, improve patient comfort and clinical outcomes.
Ebert, Lars Christian; Ptacek, Wolfgang; Breitbeck, Robert; Fürst, Martin; Kronreif, Gernot; Martinez, Rosa Maria; Thali, Michael; Flach, Patricia M
2014-06-01
In this paper we present the second prototype of a robotic system to be used in forensic medicine. The system is capable of performing automated surface documentation using photogrammetry, optical surface scanning and image-guided, post-mortem needle placement for tissue sampling, liquid sampling, or the placement of guide wires. The upgraded system includes workflow optimizations, an automatic tool-change mechanism, a new software module for trajectory planning and a fully automatic computed tomography-data-set registration algorithm. We tested the placement accuracy of the system by using a needle phantom with radiopaque markers as targets. The system is routinely used for surface documentation and resulted in 24 surface documentations over the course of 11 months. We performed accuracy tests for needle placement using a biopsy phantom, and the Virtobot placed introducer needles with an accuracy of 1.4 mm (±0.9 mm). The second prototype of the Virtobot system is an upgrade of the first prototype but mainly focuses on streamlining the workflow and increasing the level of automation and also has an easier user interface. These upgrades make the Virtobot a potentially valuable tool for case documentation in a scalpel-free setting that uses purely imaging techniques and minimally invasive procedures and is the next step toward the future of virtual autopsy.
Development of an MRI-Guided Intra-Prostatic Needle Placement System
2011-07-01
and intra-operative imaging using techniques such as those described by Haker , et al. [18]. Target points for the needle insertion are selected... Haker , S., Fichtinger, G., Tem- pany, C.: Transperineal prostate biopsy under magnetic resonance image guid- ance: A needle placement accuracy study 26...clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 42(3), 507–515 (1998) 9. DiMaio, S.P., Pieper, S., Chinzei, K., Hata, N., Haker , S.J
Picelli, Alessandro; Tamburin, Stefano; Bonetti, Paola; Fontana, Carla; Barausse, Martina; Dambruoso, Francesca; Gajofatto, Francesca; Santilli, Valter; Smania, Nicola
2012-11-01
The aim of this study was to compare the clinical outcomes of manual needle placement, electrical stimulation, and ultrasonography-guided techniques for botulinum toxin injection into the gastrocnemius of adults with spastic equinus after stroke. After randomization into three groups, each patient received the same dose of botulinum toxin type A into the lateral and medial head of the gastrocnemius muscle (OnabotulinumtoxinA, 100U per head) of the affected leg. The manual needle placement group (n = 15) underwent injections using anatomic landmarks and palpation; the electrical stimulation group (n = 15) received injections with electrical stimulation guidance; and the ultrasonography group (n = 17) was injected under sonographic guidance. The modified Ashworth scale, the Tardieu scale, and the ankle passive range of motion were measured at baseline and 1 mo after injection. Nonparametric statistical analysis was used. One month after injection, the modified Ashworth scale improved better in the ultrasonography group than in the manual needle placement group (P = 0.008). The ankle passive range of motion improved better in the ultrasonography group than in the electrical stimulation (P = 0.004) and manual needle placement (P < 0.001) groups. No difference was found between groups for the Tardieu scale. Ultrasonography-guided injection technique could improve the clinical outcome of botulinum toxin injections into the gastrocnemius of adults with spastic equinus.
Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation
Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2014-01-01
Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729
Experimental analysis of robot-assisted needle insertion into porcine liver.
Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie
2015-01-01
How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.
The anterior approach for a non-image-guided intra-articular hip injection.
Mei-Dan, Omer; McConkey, Mark O; Petersen, Brian; McCarty, Eric; Moreira, Brett; Young, David A
2013-06-01
The purpose of this study was to investigate and validate the accuracy and safety of a technique using an anterior approach for non-image-guided intra-articular injection of the hip by use of anatomic landmarks. We enrolled 55 patients. Injections were performed before supine hip arthroscopy after landmarking and before application of traction. After the needle insertion, success was confirmed with an air arthrogram and by direct visualization after arthroscope insertion. Accuracy and difficulty achieving correct needle placement were correlated with age, weight, height, body mass index, body type, gender, and surgical indication, as well as femoral and pelvic morphology. Forty-five patients who underwent injection in the office were followed up separately to document injection side effects. Needle placement accuracy was correlated to patients' demographics. All statistical tests with P values were 2 sided, with the level of significance set at P < .05. There were 51 correct needle placements and 4 misses, yielding a 93% success rate. The most common location for needle placement was the upper medial head-neck junction. Female gender was correlated with a more difficult needle placement and misses in relation to group size (P = .06). The reasons for misplacements of the needle were a high-riding trochanter, increased femoral version, thick adipose tissue over the landmarks, and variant of ilium morphology. Of 45 patients in the side effect study arm, 3 reported sensory changes of the lateral femoral cutaneous nerve that resolved within 24 hours. Hip injections by use of the direct anterior approach, from the intersection of the lines drawn from the anterior superior iliac spine and 1 cm distal to the tip of the greater trochanter, are safe and reproducible. Patient characteristics, such as increased subcutaneous adipose tissue or osseous anatomic variants, can lead to difficulty in placing the needle successfully. These characteristics can be predicted with the aid of physical examination and careful study of the pelvic radiographs. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Schalk, Richard; Schweigkofler, Uwe; Lotz, Gösta; Zacharowski, Kai; Latasch, Leo; Byhahn, Christian
2011-10-26
Intraosseous (IO) access represents a reliable alternative to intravenous vascular access and is explicitly recommended in the current guidelines of the European Resuscitation Council when intravenous access is difficult or impossible. We therefore aimed to study the efficacy of the intraosseous needle driver EZ-IO in the prehospital setting. During a 24-month period, all cases of prehospital IO access using the EZ-IO needle driver within three operational areas of emergency medical services were prospectively recorded by a standardized questionnaire that needed to be filled out by the rescuer immediately after the mission and sent to the primary investigator. We determined the rate of successful insertion of the IO needle, the time required, immediate procedure-related complications, the level of previous experience with IO access, and operator's subjective satisfaction with the device. 77 IO needle insertions were performed in 69 adults and five infants and children by emergency physicians (n = 72 applications) and paramedics (n = 5 applications). Needle placement was successful at the first attempt in all but 2 adults (one patient with unrecognized total knee arthroplasty, one case of needle obstruction after placement). The majority of users (92%) were relative novices with less than five previous IO needle placements. Of 22 responsive patients, 18 reported pain upon fluid administration via the needle. The rescuers' subjective rating regarding handling of the device and ease of needle insertion, as described by means of an analogue scale (0 = entirely unsatisfied, 10 = most satisfied), provided a median score of 10 (range 1-10). The EZ-IO needle driver was an efficient alternative to establish immediate out-of-hospital vascular access. However, significant pain upon intramedullary infusion was observed in the majority of responsive patients.
Grabo, Daniel; Inaba, Kenji; Hammer, Peter; Karamanos, Efstathios; Skiada, Dimitra; Martin, Matthew; Sullivan, Maura; Demetriades, Demetrios
2014-09-01
Tension pneumothorax can rapidly progress to cardiac arrest and death if not promptly recognized and appropriately treated. We sought to evaluate the effectiveness of traditional didactic slide-based lectures (SBLs) as compared with fresh tissue cadaver-based training (CBT) for placement of needle thoracostomy (NT). Forty randomly selected US Navy corpsmen were recruited to participate from incoming classes of the Navy Trauma Training Center at the LAC + USC Medical Center and were then randomized to one of two NT teaching methods. The following outcomes were compared between the two study arms: (1) time required to perform the procedure, (2) correct placement of the needle, and (3) magnitude of deviation from the correct position. During the study period, a total of 40 corpsmen were enrolled, 20 randomized to SBL and 20 to CBT arms. When outcomes were analyzed, time required to NT placement was not different between the two arms. Examination of the location of needle placement revealed marked differences between the two study groups. Only a minority of the SBL group (35%) placed the NT correctly in the second intercostal space. In comparison, the majority of corpsmen assigned to the CBT group demonstrated accurate placement in the second intercostal space (75%). In a CBT module, US Navy corpsmen were better trained to place NT accurately than their traditional didactic SBL counterparts. Further studies are indicated to identify the optimal components of effective simulation training for NT and other emergent interventions.
A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.
Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M
To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (<10mm) regions with high 18 F-FDG uptake within the tumour suitable for PET-guided biopsy after being located by the 3D automated application. Accuracy testing demonstrated high-precision of this semi-automatic 3D PET-guided system for breast cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.
Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay
2011-07-01
Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.
A serious game for learning ultrasound-guided needle placement skills.
Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann
2012-11-01
Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.
Lennox, Pamela H; Umedaly, Hamed S; Grant, Raymer P; White, S Adrian; Fitzmaurice, Brett G; Evans, Kenneth G
2006-10-01
The purpose of this study was to assess the validity of using a pulsatile, pressure waveform transduced from the epidural space through an epidural needle or catheter to confirm correct placement for maximal analgesia and to compare 3 different types of catheters' ability to transduce a waveform. A single-center, prospective, randomized trial. A tertiary-referral hospital. Eighty-one patients undergoing posterolateral thoracotomy who required a thoracic epidural catheter for postoperative pain management. Each epidural needle and each epidural catheter was transduced to determine if there was a pulsatile waveform exhibited. Sensitivity of the pulsatile waveform transduced through an epidural needle to identify correct placement of the epidural needle and the sensitivity of each catheter type to identify placement were compared. In 79 of 81 cases (97.5%), the waveform transduced directly through the epidural needle had a pulsatile characteristic as determined by blinded observers. In a total of 53 of 81 epidural catheters (65.4%), the transduced waveform displayed pulsations. Twenty-four of 27 catheters in group S-P/Sims Portex (Smiths Medical MD, Inc, St Paul, MN) (88.9%) transduced a pulsatile tracing from the epidural space, a significantly greater percentage than in the other 2 groups (p = 0.02). The technique of transducing the pressure waveform from the epidural needle inserted in the epidural space is a sensitive and reliable alternative to other techniques for confirmation of correct epidural catheter placement. The technique is simple, sensitive, and inexpensive and uses equipment available in any operating room.
Automatic planning of needle placement for robot-assisted percutaneous procedures.
Belbachir, Esia; Golkar, Ehsan; Bayle, Bernard; Essert, Caroline
2018-04-18
Percutaneous procedures allow interventional radiologists to perform diagnoses or treatments guided by an imaging device, typically a computed tomography (CT) scanner with a high spatial resolution. To reduce exposure to radiations and improve accuracy, robotic assistance to needle insertion is considered in the case of X-ray guided procedures. We introduce a planning algorithm that computes a needle placement compatible with both the patient's anatomy and the accessibility of the robot within the scanner gantry. Our preoperative planning approach is based on inverse kinematics, fast collision detection, and bidirectional rapidly exploring random trees coupled with an efficient strategy of node addition. The algorithm computes the allowed needle entry zones over the patient's skin (accessibility map) from 3D models of the patient's anatomy, the environment (CT, bed), and the robot. The result includes the admissible robot joint path to target the prescribed internal point, through the entry point. A retrospective study was performed on 16 patients datasets in different conditions: without robot (WR) and with the robot on the left or the right side of the bed (RL/RR). We provide an accessibility map ensuring a collision-free path of the robot and allowing for a needle placement compatible with the patient's anatomy. The result is obtained in an average time of about 1 min, even in difficult cases. The accessibility maps of RL and RR covered about a half of the surface of WR map in average, which offers a variety of options to insert the needle with the robot. We also measured the average distance between the needle and major obstacles such as the vessels and found that RL and RR produced needle placements almost as safe as WR. The introduced planning method helped us prove that it is possible to use such a "general purpose" redundant manipulator equipped with a dedicated tool to perform percutaneous interventions in cluttered spaces like a CT gantry.
Eslami, Sohrab; Shang, Weijian; Li, Gang; Patel, Nirav; Fischer, Gregory S.; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian
2015-01-01
Background The robot-assisted minimally-invasive surgery is well recognized as a feasible solution for diagnosis and treatment of the prostate cancer in human. Methods In this paper the kinematics of a parallel 4 Degrees-of-Freedom (DOF) surgical manipulator designed for minimally invasive in-bore prostate percutaneous interventions through the patient's perineum. The proposed manipulator takes advantage of 4 sliders actuated by MRI-compatible piezoelectric motors and incremental rotary encoders. Errors, mostly originating from the design and manufacturing process, need to be identified and reduced before the robot is deployed in the clinical trials. Results The manipulator has undergone several experiments to evaluate the repeatability and accuracy of the needle placement which is an essential concern in percutaneous prostate interventions. Conclusion The acquired results endorse the sustainability, precision (about 1 mm in air (in x or y direction) at the needle's reference point) and reliability of the manipulator. PMID:26111458
Autonomous Rover Traverse and Precise Arm Placement on Remotely Designated Targets
NASA Technical Reports Server (NTRS)
Felder, Michael; Nesnas, Issa A.; Pivtoraiko, Mihail; Kelly, Alonzo; Volpe, Richard
2011-01-01
Exploring planetary surfaces typically involves traversing challenging and unknown terrain and acquiring in-situ measurements at designated locations using arm-mounted instruments. We present field results for a new implementation of an autonomous capability that enables a rover to traverse and precisely place an arm-mounted instrument on remote targets. Using point-and-click mouse commands, a scientist designates targets in the initial imagery acquired from the rover's mast cameras. The rover then autonomously traverse the rocky terrain for a distance of 10 - 15 m, tracks the target(s) of interest during the traverse, positions itself for approaching the target, and then precisely places an arm-mounted instrument within 2-3 cm from the originally designated target. The rover proceeds to acquire science measurements with the instrument. This work advances what has been previously developed and integrated on the Mars Exploration Rovers by using algorithms that are capable of traversing more rock-dense terrains, enabling tight thread-the-needle maneuvers. We integrated these algorithms on the newly refurbished Athena Mars research rover and fielded them in the JPL Mars Yard. We conducted 43 runs with targets at distances ranging from 5 m to 15 m and achieved a success rate of 93% for placement of the instrument within 2-3 cm.
Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko
2015-07-01
To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.
Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I
2017-03-01
Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect needle visibility. We found that the use of Infiniti Plus decreased the median time to successfully place a femoral nerve catheter by 33% compared with not using Infiniti Plus. This difference may be more apparent to clinicians undertaking this procedure less often or by those in training as our team was very experienced, had been trained in the technique and was working in a hospital with a large caseload. Clinicaltrials.gov identifier: NCT02080481.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.
Podder, Tarun K; Beaulieu, Luc; Caldwell, Barrett; Cormack, Robert A; Crass, Jostin B; Dicker, Adam P; Fenster, Aaron; Fichtinger, Gabor; Meltsner, Michael A; Moerland, Marinus A; Nath, Ravinder; Rivard, Mark J; Salcudean, Tim; Song, Danny Y; Thomadsen, Bruce R; Yu, Yan
2014-10-01
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicists in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy & Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3-6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot-clinician and robot-patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.
Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600
Laparoscopic access with a visualizing trocar.
Wolf, J S
1997-01-01
Although useful in most situations, there are several inherent disadvantages of the standard laparoscopic access techniques of Veress needle insertion and Hasson-type cannula placement. Veress needle placement may be hazardous in patients at high risk for intraabdominal adhesions and difficult in patients who are obese. The usual alternative, the Hasson-type cannula, often does not provide a good gas seal. As another option, the use of a visualizing trocar (OPTIVIEW) has proven to be effective in the initial experience at the University of Michigan. The inner trocar of the visualizing trocar is hollow except for a clear plastic conical tip with two external ridges. The trocar-cannula assembly is passed through tissue layers to enter the operative space under direct vision from a 10-mm zero-degree laparoscope placed into the trocar. Results suggest that this technique is an excellent alternative to Veress needle placement when laparoscopic access is likely to be hazardous or difficult.
Manggala, Sidharta K.; Tantri, Aida R.; Satoto, Darto
2016-01-01
Background The patient’s position during spinal anesthesia administration plays a major role in the success of spinal needle insertion into the subarachnoid space. The traditional sitting position (TSP) is the standard position for spinal anesthesia administration, but the success rate for spinal anesthesia administration in the TSP is still quite low. The crossed-leg sitting position (CLSP) is one of the alternative positions for the administration of spinal anesthesia, which can increase the degree of lumbar flexion. Objectives This study aimed to compare successful spinal needle placement to patients in the CLSP and patients in the TSP prior to undergoing urology surgery. Methods This study was a non-blinded, randomized controlled trial in patients undergoing spinal anesthesia for urologic procedures from March-October, 2015 in the central national hospital Dr. Cipto Mangunkusumo, Indonesia. After obtaining approval from the FMUI – RSCM (Faculty of Medicine Universitas Indonesia – Rumah Sakit Dr. Cipto Mangunkusumo) Ethical Committee and informed consent from patients, 211 subjects were allocated into two groups: the CLSP group (n = 105) and the TSP group (n = 106). The proportion of successful spinal needle placement to the subarachnoid space, ease of landmark palpation, and the number of needle-bone contacts in both groups were then assessed and analyzed. Results The rate of first-time successful spinal needle insertion was not significantly different between the CLSP and TSP groups (62.9% versus 55.7%, P > 0.05). Ease of landmark palpation in the CLSP group was not significantly different from that in the TSP group (86.7% versus 76.4%, P > 0.05). The number of needle-bone contacts in both groups were not significantly different (P > 0.05). The complication rates were similar in both groups. Conclusions The rate of successful spinal needle placement in the CLSP group was not significantly different from that in the TSP group in patients undergoing urology surgery. The CLSP can be used as an alternative sitting position for administration of spinal anesthesia. PMID:27843785
Toward realistic radiofrequency ablation of hepatic tumors 3D simulation and planning
NASA Astrophysics Data System (ADS)
Villard, Caroline; Soler, Luc; Gangi, Afshin; Mutter, Didier; Marescaux, Jacques
2004-05-01
Radiofrequency ablation (RFA) has become an increasingly used technique in the treatment of patients with unresectable hepatic tumors. Evaluation of vascular architecture, post-RFA tissue necrosis prediction, and the choice of a suitable needle placement strategy using conventional radiological techniques remain difficult. In an attempt to enhance the safety of RFA, a 3D simulator and treatment planning tool, that simulates the necrosis of the treated area, and proposes an optimal placement for the needle, has been developed. From enhanced spiral CT scans with 2 mm cuts, 3D reconstructions of patients with liver metastases are automatically generated. Virtual needles can be added to the 3D scene, together with their corresponding zones of necrosis that are displayed as a meshed spheroids representing the 60° C isosurface. The simulator takes into account the cooling effect of local vessels greater than 3mm in diameter, making necrosis shapes more realistic. Using a voxel-based algorithm, RFA spheroids are deformed following the shape of the vessels, extended by an additional cooled area. This operation is performed in real-time, allowing updates while needle is adjusted. This allows to observe whether the considered needle placement strategy would burn the whole cancerous zone or not. Planned needle positioning can also be automatically generated by the software to produce complete destruction of the tumor with a 1 cm margin, with maximum respect of the healthy liver and of all major extrahepatic and intrahepatic structures to avoid. If he wishes, the radiologist can select on the skin an insertion window for the needle, focusing the research of the trajectory.
A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.
Hocking, Graham; Hebard, Simon; Mitchell, Christopher H
2011-01-01
With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine
Cadaveric validation of dry needle placement in the lateral pterygoid muscle.
Mesa-Jiménez, Juan A; Sánchez-Gutiérrez, Jesús; de-la-Hoz-Aizpurua, José L; Fernández-de-las-Peñas, César
2015-02-01
The aim of this anatomical study was to determine if a needle is able to reach the lateral pterygoid muscle during the application of dry needling technique. A dry needling approach using 2 needles of 50 to 60 mm in length, one inserted over the zygomatic process posterior at the obituary arch (for the superior head) and other inserted below the zygomatic process between the mandibular condyle and the coronoid process (for the inferior head), was proposed. A progressive dissection into 3 stages was conducted into 2 heads of fresh male cadavers. First, dry needling of the lateral pterygoid muscle was applied on the cadaver. Second, a block dissection containing the lateral pterygoid was harvested. Finally, the ramus of the mandible was sectioned by osteotomy to visualize the lateral pterygoid muscle with the needle placements. With the needles inserted into the cadaver, the block dissection revealed that the superior needle reached the superior (sphenoid) head of the lateral pterygoid muscle and the inferior needle reached the inferior (pterygoid) head of the muscle. At the final stage of the dissection, when the ramus of the mandible was sectioned by osteotomy, it was revealed that the superior needle entered into the belly of the superior head of the lateral pterygoid muscle. This anatomical study supports that dry needling technique for the lateral pterygoid muscle can be properly conducted with the proposed approach. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, T
Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system.more » Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.« less
NASA Astrophysics Data System (ADS)
Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming
2018-03-01
In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.
Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions
Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor
2011-01-01
Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. PMID:21686038
Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.
Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor
2008-06-13
Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.
Rodgers, Jessica Robin; Surry, Kathleen; Leung, Eric; D'Souza, David; Fenster, Aaron
2017-05-01
Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical postinsertion CT scan based on the vaginal cylinder of the needle template. The positions of the tips and the trajectory of the needle paths were compared between the modalities. The observed geometric errors of the system were ≤ 0.3 mm in each of the three coordinate planes of the 3D US image and the mean measured volumetric error was 0.10 cm 3 . In the phantom study, the mean needle tip difference was 1.54 ± 0.71 mm and the mean trajectory difference was 0.94 ± 0.89 degrees (n = 14). In the in vivo study, a total of 73 needles were placed, of which 88% of needles were visible and 79% of tips were identifiable in the 3D TRUS images. Six of the nine needles that were not visible were due to shadowing artifacts created by the presence of the vaginal cylinder of the needle template. The mean distance between corresponding needle tips in the two modalities was 3.82 ± 1.86 mm and the mean trajectory difference was 3.04 ± 1.63 degrees for the five patients. In this proof-of-concept study, the 3D TRUS system allowed for localization of needles not obscured by shadowing artifacts, providing a method for visualizing needles intra-operatively during HDR interstitial brachytherapy of gynecologic cancers and providing the potential for 3D image-guidance. © 2017 American Association of Physicists in Medicine.
Percutaneous needle placement using laser guidance: a practical solution
NASA Astrophysics Data System (ADS)
Xu, Sheng; Kapoor, Ankur; Abi-Jaoudeh, Nadine; Imbesi, Kimberly; Hong, Cheng William; Mazilu, Dumitru; Sharma, Karun; Venkatesan, Aradhana M.; Levy, Elliot; Wood, Bradford J.
2013-03-01
In interventional radiology, various navigation technologies have emerged aiming to improve the accuracy of device deployment and potentially the clinical outcomes of minimally invasive procedures. While these technologies' performance has been explored extensively, their impact on daily clinical practice remains undetermined due to the additional cost and complexity, modification of standard devices (e.g. electromagnetic tracking), and different levels of experience among physicians. Taking these factors into consideration, a robotic laser guidance system for percutaneous needle placement is developed. The laser guidance system projects a laser guide line onto the skin entry point of the patient, helping the physician to align the needle with the planned path of the preoperative CT scan. To minimize changes to the standard workflow, the robot is integrated with the CT scanner via optical tracking. As a result, no registration between the robot and CT is needed. The robot can compensate for the motion of the equipment and keep the laser guide line aligned with the biopsy path in real-time. Phantom experiments showed that the guidance system can benefit physicians at different skill levels, while clinical studies showed improved accuracy over conventional freehand needle insertion. The technology is safe, easy to use, and does not involve additional disposable costs. It is our expectation that this technology can be accepted by interventional radiologists for CT guided needle placement procedures.
Berber, Eren
2015-07-01
Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. The patients had an average of two tumours (range 1-4), measuring 1.9 ± 0.4 cm (range 0.9-4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5-10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. © 2015 International Hepato-Pancreato-Biliary Association.
Mizuno, Kentaro; Mikami, Yasuo; Hase, Hitoshi; Ikeda, Takumi; Nagae, Masateru; Tonomura, Hitoshi; Shirai, Toshiharu; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2017-02-01
A technical note and retrospective study. The objectives were to describe a new method of drainage tube placement during microendoscopic spinal decompression, and compare the positioning and fluid discharge obtained with this method and the conventional method. To prevent postoperative epidural hematoma after microendoscopic decompression, a drainage tube must be placed in a suitable location. However, the narrow operative field makes precise control of the position of the tube technically difficult. We developed a method to reliably place the tube in the desired location. We use a Deschamps aneurysm needle with a slightly curved tip, which we call a drain passer. With the microendoscope in position, the drain passer, with a silk thread passed through the eye at the needle tip, is inserted percutaneously into the endoscopic field of view. The drainage tube is passed through the loop of silk thread protruding from the inside of the tubular retractor, and the thread is pulled to the outside, guiding the end of the drainage tube into the wound. This method was used in 23 cases at 44 intervertebral levels (drain passer group), and the conventional method in 20 cases at 32 intervertebral levels (conventional group). Postoperative plain radiographs were taken, and the amount of fluid discharge at postoperative hour 24 was measured. Drainage tube positioning was favorable at 43 intervertebral levels (97.7%) in the drain passer group and 26 intervertebral levels (81.3%) in the conventional group. Mean fluid discharge was 58.4±32.2 g in the drain passer group and 38.4±23.0 g in the conventional group. Positioning was significantly better and fluid discharge was significantly greater in the drain passer group. The results indicate that this method is a useful drainage tube placement technique for preventing postoperative epidural hematoma.
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podder, Tarun K., E-mail: tarun.podder@uhhospitals.org; Beaulieu, Luc; Caldwell, Barrett
In the last decade, there have been significant developments into integration of robots and automation tools with brachytherapy delivery systems. These systems aim to improve the current paradigm by executing higher precision and accuracy in seed placement, improving calculation of optimal seed locations, minimizing surgical trauma, and reducing radiation exposure to medical staff. Most of the applications of this technology have been in the implantation of seeds in patients with early-stage prostate cancer. Nevertheless, the techniques apply to any clinical site where interstitial brachytherapy is appropriate. In consideration of the rapid developments in this area, the American Association of Physicistsmore » in Medicine (AAPM) commissioned Task Group 192 to review the state-of-the-art in the field of robotic interstitial brachytherapy. This is a joint Task Group with the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO). All developed and reported robotic brachytherapy systems were reviewed. Commissioning and quality assurance procedures for the safe and consistent use of these systems are also provided. Manual seed placement techniques with a rigid template have an estimated in vivo accuracy of 3–6 mm. In addition to the placement accuracy, factors such as tissue deformation, needle deviation, and edema may result in a delivered dose distribution that differs from the preimplant or intraoperative plan. However, real-time needle tracking and seed identification for dynamic updating of dosimetry may improve the quality of seed implantation. The AAPM and GEC-ESTRO recommend that robotic systems should demonstrate a spatial accuracy of seed placement ≤1.0 mm in a phantom. This recommendation is based on the current performance of existing robotic brachytherapy systems and propagation of uncertainties. During clinical commissioning, tests should be conducted to ensure that this level of accuracy is achieved. These tests should mimic the real operating procedure as closely as possible. Additional recommendations on robotic brachytherapy systems include display of the operational state; capability of manual override; documented policies for independent check and data verification; intuitive interface displaying the implantation plan and visualization of needle positions and seed locations relative to the target anatomy; needle insertion in a sequential order; robot–clinician and robot–patient interactions robustness, reliability, and safety while delivering the correct dose at the correct site for the correct patient; avoidance of excessive force on radioactive sources; delivery confirmation of the required number or position of seeds; incorporation of a collision avoidance system; system cleaning, decontamination, and sterilization procedures. These recommendations are applicable to end users and manufacturers of robotic brachytherapy systems.« less
SU-D-213AB-06: Surface Texture and Insertion Speed Effect on Needle Friction.
Abdullah, A; Golecki, C; Barnett, A; Moore, J
2012-06-01
High frictional forces between the needle surface and tissue cause tissue deflection which hinders accurate needle placement for procedures such as brachytherapy and needle biopsy. Accurate needle placement isimportant to maximize procedure efficacy. This work investigates how needle surface roughness and insertion speed affect the frictional forcebetween a needle and tissue. A friction experiment was conducted to measure the force of friction between bovine liver and three 11 gauge needles having Ra surface roughness of 3.43, 1.33, and 0.2 μm. Each of the three needles were mounted on a linear slide and were advanced and retracted through bovine liver at speeds of 50, 100, 150, and 200 mm/s for a total of 12 trials. In each trial the needle was advanced and retracted in 10 cycles producing a steady state insertion force and a steady state retraction force for each cycle. A force sensor connecting the needle to the linear slide recorded the resistance force of the needle sliding through the liver. The liver was mounted in a box with a pneumatic cylinder which compressed the liver sample by 11.65 kPa. The roughest needle (Ra = 3.43 μm) on average produced 68, 73, 74, and 73% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200mm/s, respectively. The second roughest needle (Ra = 1.33 μm) on average produced 25, 45, 60 and 64% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200 mm/s, respectively. Rougher needle surface texture and higher insertion speed reduced frictional forces between the tissue and the needle. Future studies will examine how frictional forces can be modeled and predicted given surface texture and insertion speed. © 2012 American Association of Physicists in Medicine.
Li, Meng; Li, Gang; Gonenc, Berk; Duan, Xingguang; Iordachita, Iulian
2017-06-01
Accurate needle placement into soft tissue is essential to percutaneous prostate cancer diagnosis and treatment procedures. This paper discusses the steering of a 20 gauge (G) FBG-integrated needle with three sets of Fiber Bragg Grating (FBG) sensors. A fourth-order polynomial shape reconstruction method is introduced and compared with previous approaches. To control the needle, a bicycle model based navigation method is developed to provide visual guidance lines for clinicians. A real-time model updating method is proposed for needle steering inside inhomogeneous tissue. A series of experiments were performed to evaluate the proposed needle shape reconstruction, visual guidance and real-time model updating methods. Targeting experiments were performed in soft plastic phantoms and in vitro tissues with insertion depths ranging between 90 and 120 mm. Average targeting errors calculated based upon the acquired camera images were 0.40 ± 0.35 mm in homogeneous plastic phantoms, 0.61 ± 0.45 mm in multilayer plastic phantoms and 0.69 ± 0.25 mm in ex vivo tissue. Results endorse the feasibility and accuracy of the needle shape reconstruction and visual guidance methods developed in this work. The approach implemented for the multilayer phantom study could facilitate accurate needle placement efforts in real inhomogeneous tissues. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
CT-Guided Placement of a Drainage Catheter Within a Pelvic Abscess Using a Transsacral Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iguchi, Toshihiro; Asami, Shinya; Kubo, Shinichiro
2007-11-15
A 66-year-old man underwent CT-guided drainage catheter placement within a pelvic abscess with a diameter of 46 mm. We performed the drainage by a transsacral approach because it was considered the safest and most feasible approach. An 8G bone marrow biopsy needle was used to penetrate the sacrum to create a path for subsequent drainage catheter insertion. After withdrawal of the biopsy needle, a 6 Fr catheter was advanced into the abscess cavity through the path using the Seldinger technique. Except for bearable pain, no procedure-related complications occurred. Twenty-nine days after the placement, the catheter was withdrawn safely and themore » abscess cavity had shrunk remarkably.« less
Intravascular flow detection during transforaminal epidural injections: a prospective assessment.
El Abd, Omar Hamman; Amadera, Joao Eduardo Daud; Pimentel, Daniel Camargo; Pimentel, Thais Spacov Camargo
2014-01-01
Transforaminal epidural steroid injections (TFESI) are a mainstay in the treatment of spine pain. Though this commonly performed procedure is generally felt to be safe, devastating complications following inadvertent intra-arterial injections of particulate steroid have been reported. The use of digital subtraction angiography (DSA) has been suggested as a means of detecting intra-arterial needle placements prior to medication injection. To examine the efficacy of DSA in detecting intra-arterial needle placements during TFESI. Prospective cohort study evaluating the impact of DSA on detecting intra-arterial needle placements during TFESI. We enrolled 150 consecutive patients presenting to a university-affiliated spine center with discogenic and/or radicular symptoms affecting the cervical, lumbar, and sacral regions. For each injection, prior to imaging with DSA, traditional methods for vascular penetration detection were employed, including the identification of blood in the needle hub (flash), negative aspiration of blood prior to injection, and live fluoroscopic injection of contrast. Once these tests were performed and negative for signs of intra-arterial needle placement, DSA imaging was utilized prior to medication administration for identification of vascular flow. A total number of 222 TFESI were performed, 41 injections at the cervical levels (18.47%), 113 at the lumbar levels (50.9%), and 68 at the sacral levels (30.36%). Flash was observed in 13 injections performed (5.85% of the total number of injections): one (0.45%) in the cervical, 2 (0.9%) in the lumbar, and 10 (4.5%) in the sacral levels. In 11 TFESI blood aspiration was obtained (4.95% of all injections): 3 (1.3%) in cervical, 4 (1.8%) in lumbar, and 4 (1.8%) in sacral injections. Live fluoroscopy during contrast injection detected 46 (20.72%) intravascular flow patterns: 7 (3.1%) cervical, 17 (7.6%) lumbar, and 22 (9.9%) sacral. DSA identified an additional 5 intravascular injections after all previous steps had resulted in negative vascular penetration signs, which accounted for 2.25% of all injections. This is a prospective, single-center study with a relatively small number of patients and no control group. DSA detected additional 5.26% intravascular needle placements following traditional methods. Our findings also support other studies that conclude TFESI are generally a safe procedure. We recommend that special attention should be paid to the sacral injections as vascular penetration was statistically higher than at other levels.
Precision grid and hand motion for accurate needle insertion in brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.
2011-08-15
Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on themore » measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.« less
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia
2012-08-15
Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less
Villard, Caroline; Soler, Luc; Gangi, Afshin
2005-08-01
For radiofrequency ablation (RFA) of liver tumors, evaluation of vascular architecture, post-RFA necrosis prediction, and the choice of a suitable needle placement strategy using conventional radiological techniques remain difficult. In an attempt to enhance the safety of RFA, a 3D simulator, treatment planning, and training tool, that simulates the insertion of the needle, the necrosis of the treated area, and proposes an optimal needle placement, has been developed. The 3D scenes are automatically reconstructed from enhanced spiral CT scans. The simulator takes into account the cooling effect of local vessels greater than 3 mm in diameter, making necrosis shapes more realistic. Optimal needle positioning can be automatically generated by the software to produce complete destruction of the tumor, with maximum respect of the healthy liver and of all major structures to avoid. We also studied how the use of virtual reality and haptic devices are valuable to make simulation and training realistic and effective.
Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.
Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R
2008-12-01
Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.
Berber, Eren
2015-01-01
Background Liver tumour ablation is an operator-dependent procedure. The determination of the optimum needle trajectory and correct ablation parameters could be challenging. The aim of this study was to report the utility of a new, procedure planning software for microwave ablation (MWA) of liver tumours. Methods This was a feasibility study in a pilot group of five patients with nine metastatic liver tumours who underwent laparoscopic MWA. Pre-operatively, parameters predicting the desired ablation zones were calculated for each tumour. Intra-operatively, this planning strategy was followed for both antenna placement and energy application. Post-operative 2-week computed tomography (CT) scans were performed to evaluate complete tumour destruction. Results The patients had an average of two tumours (range 1–4), measuring 1.9 ± 0.4 cm (range 0.9–4.4 cm). The ablation time was 7.1 ± 1.3 min (range 2.5–10 min) at 100W. There were no complications or mortality. The patients were discharged home on post-operative day (POD) 1. At 2-week CT scans, there were no residual tumours, with a complete ablation demonstrated in all lesions. Conclusions This study describes and validates pre-treatment planning software for MWA of liver tumours. This software was found useful to determine precisely the ablation parameters and needle placement to create a predicted zone of ablation. PMID:25980481
Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery
NASA Astrophysics Data System (ADS)
Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.
2017-03-01
Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.
Intrauterine transfusion with the use of phased array ultrasonography: a new technique.
Frigoletto, F D; Birnholz, J C; Rothchild, S B; Finberg, H J; Umansky, I
1978-06-01
Continuous ultrasonic observation of needle placement for aspiration, biopsy, or catheter placement is a novel and specific use of phased array imaging. In the case of IUTx, catheter placement into the fetal peritoneal space is accomplished rapidly, with reduced risk of fetal trauma, and without exposure to ionizing radiation. Experience with 27 transfusions in 11 patients is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braak, Sicco J., E-mail: sjbraak@gmail.com; Zuurmond, Kirsten, E-mail: kirsten.zuurmond@philips.com; Aerts, Hans C. J., E-mail: hans.cj.aerts@philips.com
2013-08-01
ObjectiveTo investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.Materials and MethodsOn 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed tomore » determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.ResultsMean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm{sup 2}, respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.ConclusionCBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.« less
Yeo, Caitlin T; Ungi, Tamas; U-Thainual, Paweena; Lasso, Andras; McGraw, Robert C; Fichtinger, Gabor
2011-07-01
The purpose of this study was to determine if augmented reality image overlay and laser guidance systems can assist medical trainees in learning the correct placement of a needle for percutaneous facet joint injection. The Perk Station training suite was used to conduct and record the needle insertion procedures. A total of 40 volunteers were randomized into two groups of 20. 1) The Overlay group received a training session that consisted of four insertions with image and laser guidance, followed by two insertions with laser overlay only. 2) The Control group received a training session of six classical freehand insertions. Both groups then conducted two freehand insertions. The movement of the needle was tracked during the series of insertions. The final insertion procedure was assessed to determine if there was a benefit to the overlay method compared to the freehand insertions. The Overlay group had a better success rate (83.3% versus 68.4%, p=0.002), and potential for less tissue damage as measured by the amount of needle movement inside the phantom (3077.6 mm(2) versus 5607.9 mm(2) , p =0.01). These results suggest that an augmented reality overlay guidance system can assist medical trainees in acquiring technical competence in a percutaneous needle insertion procedure. © 2011 IEEE
SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joseph, F Maria; Podder, T; Yu, Y
Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostatemore » HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.« less
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
Needle placement for piriformis injection using 3-D imaging.
Clendenen, Steven R; Candler, Shawn A; Osborne, Michael D; Palmer, Scott C; Duench, Stephanie; Glynn, Laura; Ghazi, Salim M
2013-01-01
Piriformis syndrome is a pain syndrome originating in the buttock and is attributed to 6% - 8% of patients referred for the treatment of back and leg pain. The treatment for piriformis syndrome using fluoroscopy, computed tomography (CT), electromyography (EMG), and ultrasound (US) has become standard practice. The treatment of Piriformis Syndrome has evolved to include fluoroscopy and EMG with CT guidance. We present a case study of 5 successful piriformis injections using 3-D computer-assisted electromagnet needle tracking coupled with ultrasound. A 6-degree of freedom electromagnetic position tracker was attached to the ultrasound probe that allowed the system to detect the position and orientation of the probe in the magnetic field. The tracked ultrasound probe was used to find the posterior superior iliac spine. Subsequently, 3 points were captured to register the ultrasound image with the CT or magnetic resonance image scan. Moreover, after the registration was obtained, the navigation system visualized the tracked needle relative to the CT scan in real-time using 2 orthogonal multi-planar reconstructions centered at the tracked needle tip. Conversely, a recent study revealed that fluoroscopically guided injections had 30% accuracy compared to ultrasound guided injections, which tripled the accuracy percentage. This novel technique exhibited an accurate needle guidance injection precision of 98% while advancing to the piriformis muscle and avoiding the sciatic nerve. The mean (± SD) procedure time was 19.08 (± 4.9) minutes. This technique allows for electromagnetic instrument tip tracking with real-time 3-D guidance to the selected target. As with any new technique, a learning curve is expected; however, this technique could offer an alternative, minimizing radiation exposure.
Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.
Gofeld, Michael; Krashin, Daniel L; Ahn, Sangmin
2013-01-01
Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. Experimental laboratory study. Willed Body Program, University of Washington. In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility and should be used whenever possible.
NASA Astrophysics Data System (ADS)
Pekárek, Stanislav
2014-12-01
For the hollow-needle-to-mesh negative corona discharge in air, we studied the effect of placing the dielectric tube on the needle electrode and the effect of various positions of the end of this tube with respect to the tip of the needle electrode on the concentration of ozone produced by the discharge, the ozone production yield and the discharge V-A characteristics. We found that the placement of the dielectric tube on the needle electrode with a suitable position of this tube end with respect to the tip of the needle electrode for a particular discharge power led to a more than fourfold increase in the concentration of ozone produced by the discharge and also, for a constant airflow, the ozone production yield.
Yang, Toni; Shmalberg, Justin; Hochman, Lindsay; Miscioscia, Erin; Brumby, Meghan; McKenna, Kelsey; Roth, Amber
2017-10-01
Veterinary acupuncture is becoming increasingly implemented for various disease processes, with growing numbers of veterinarians pursuing advanced training to meet the rising demand for this relatively new intervention. Accurate acupoint placement remains challenging, with individual practitioners relying on varying methods of point identification, often compounded by the transpositional nature of points for companion animals. The aim of this study was to assess for differences in acupuncture needle placement of select points between veterinary professionals with three different levels of acupuncture training in an academic teaching environment. Seven participants placed a total of six acupoints on a canine cadaver. Digital radiography was used to document each participant's point placement. Each participant's point location was then compared to a control "correct" point, and the distance between the two points was measured. A significant difference in placement accuracy was identified between the participants when grouped by training level (p = 0.03). These results indicate that veterinary patients receiving acupuncture treatment from veterinarians with different levels of training may subsequently experience varying effects, although further studies are warranted on more specific acupoint description as well as the clinical implications of needle placement accuracy. Copyright © 2017. Published by Elsevier B.V.
Teleoperated master-slave needle insertion.
Abolhassani, Niki; Patel, Rajni V
2009-12-01
Accuracy of needle tip placement and needle tracking in soft tissue are of particular importance in many medical procedures. In recent years, developing autonomous and teleoperated systems for needle insertion has become an active area of research. In this study, needle insertion was performed using a master-slave set-up with multi-degrees of freedom. The effect of force feedback on the accuracy of needle insertion was investigated. In addition, this study compared autonomous, teleoperated and semi-autonomous needle insertion. The results of this study show that incorporation of force feedback can improve teleoperated needle insertion. However, autonomous and semi-autonomous needle insertions, which use feedback from a deflection model, provide significantly better performance. Development of a haptic master-slave needle insertion system, which is capable of performing some autonomous tasks based on feedback from tissue deformation and needle deflection models, can improve the performance of autonomous robotics-based insertions as well as non-autonomous teleoperated manual insertions. Copyright (c) 2009 John Wiley & Sons, Ltd.
Mabray, Marc C; Datta, Sanjit; Lillaney, Prasheel V; Moore, Teri; Gehrisch, Sonja; Talbott, Jason F; Levitt, Michael R; Ghodke, Basavaraj V; Larson, Paul S; Cooke, Daniel L
2016-07-01
Fluoroscopic systems in modern interventional suites have the ability to perform flat panel detector CT (FDCT) with navigational guidance. Fusion with MR allows navigational guidance towards FDCT occult targets. We aim to evaluate the accuracy of this system using single-pass needle placement in a deep brain stimulation (DBS) phantom. MR was performed on a head phantom with DBS lead targets. The head phantom was placed into fixation and FDCT was performed. FDCT and MR datasets were automatically fused using the integrated guidance system (iGuide, Siemens). A DBS target was selected on the MR dataset. A 10 cm, 19 G needle was advanced by hand in a single pass using laser crosshair guidance. Radial error was visually assessed against measurement markers on the target and by a second FDCT. Ten needles were placed using CT-MR fusion and 10 needles were placed without MR fusion, with targeting based solely on FDCT and fusion steps repeated for every pass. Mean radial error was 2.75±1.39 mm as defined by visual assessment to the centre of the DBS target and 2.80±1.43 mm as defined by FDCT to the centre of the selected target point. There were no statistically significant differences in error between MR fusion and non-MR guided series. Single pass needle placement in a DBS phantom using FDCT guidance is associated with a radial error of approximately 2.5-3.0 mm at a depth of approximately 80 mm. This system could accurately target sub-centimetre intracranial lesions defined on MR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.
Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir
2010-01-01
In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.
CT-guided thermocouple placement for hyperthermia treatment.
Banerian, K G; Roberts, J L; Borrego, J C; Martinez, A
1990-05-01
There is a well-documented synergistic cytotoxic effect when heat is combined with ionizing radiation. An integral component of hyperthermia treatments is the placement of thermocouple probes used for thermal dosimetry. With the surge in interest in the clinical use of hyperthermia, our department is performing an increasing number of thermocouple placements under computed tomographic (CT) guidance. We describe our technique for CT-guided thermocouple placement with two different systems: a trocar introduction system and a peel-away needle introduction system. We discuss the rationale for thermocouple placement, our early experience with this technique, and some potential complications.
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.
2014-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S
2013-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.
Koontz, Nicholas A; Wiggins, Richard H; Stoddard, Gregory J; Shah, Lubdha M
2017-10-01
There is a paucity of evidence-based literature regarding the advantages and disadvantages of the interlaminar approach and needle bevel orientation for performing a lumbar interlaminar epidural steroid injection (ESI). The purpose of this study was to determine if superior versus inferior lamina approach, needle bevel tip orientation, or both may predispose to inadvertent nonepidural penetration during lumbar interlaminar ESI. A prospective study was performed of patients with low back pain with or without radicular pain or neurogenic claudication referred for lumbar interlaminar ESI. Two hundred eleven patients were randomized by interlaminar approach (superior vs inferior) and bevel tip orientation (cranial vs caudal). Lumbar interlaminar ESI was performed by six interventionalists of varying levels of experience using fluoroscopic guidance with curved tip epidural needles, using loss-of-resistance technique and confirmation with contrast opacification. Exact Poisson regression was used to model the study outcome. Two hundred twenty-one lumbar interlaminar ESIs were performed on 211 patients, randomized to a superior (n = 121) or inferior lamina approach (n = 100) and to a cranial (n = 103) or caudal (n = 118) orientation of the bevel tip. Epidural needle placement was confirmed in 96.4% (n = 213) of cases. Nonepidural needle placement was most commonly associated with superior lamina approach and caudal bevel tip orientation, which was marginally significant (adjusted risk ratio, 6.88; 95% CI, 0.93-∞; p = 0.059). Inadvertent nonepidural needle penetration during fluoroscopically guided lumbar interlaminar ESI appears to be affected by approach, with superior lamina approach and caudal bevel tip orientation being the least favorable technique.
NASA Astrophysics Data System (ADS)
Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.
2015-10-01
Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.
Virtual remote center of motion control for needle placement robots.
Boctor, Emad M; Webster, Robert J; Mathieu, Herve; Okamura, Allison M; Fichtinger, Gabor
2004-01-01
We present an algorithm that enables percutaneous needle-placement procedures to be performed with unencoded, unregistered, minimally calibrated robots while removing the constraint of placing the needle tip on a mechanically enforced Remote Center of Motion (RCM). The algorithm requires only online tracking of the surgical tool and a five-degree-of-freedom (5-DOF) robot comprising three prismatic DOF and two rotational DOF. An incremental adaptive motion control cycle guides the needle to the insertion point and also orients it to align with the target-entry-point line. The robot executes RCM motion without having a physically constrained fulcrum point. The proof-of-concept prototype system achieved 0.78 mm translation accuracy and 1.4 degrees rotational accuracy (this is within the tracker accuracy) within 17 iterative steps (0.5-1 s). This research enables robotic assistant systems for image-guided percutaneous procedures to be prototyped/constructed more quickly and less expensively than has been previously possible. Since the clinical utility of such systems is clear and has been demonstrated in the literature, our work may help promote widespread clinical adoption of this technology by lowering system cost and complexity.
Fluoroscopy-Guided Sacroiliac Joint Injection: Description of a Modified Technique.
Kasliwal, Prasad Jaychand; Kasliwal, Sapana
2016-02-01
Sacroiliac joint (SIJ) pathology is a common etiologic cause for 10 - 27% of cases of mechanical low back pain (LBP) below the L5 level. In the absence of definite clinical or radiologic diagnostic criteria, controlled blocks of the SIJ have become the choice assessment method for making the diagnosis of SIJ pain. The SI joint is most often characterized as a large, auricular-shaped, diarthrodial synovial joint. In reality, its synovial characteristic is limited only to the distal third and anterior third. In SIJ interventions, the lateral view has been underutilized. In our technique, we used the lateral view to create a three-dimensional view of the SIJ to aid in gauging the accurateness of the contrast spread and to obtain a precise block. After obtaining appropriate fluoroscopic images, a curved tip spinal needle was directed into the inferior aspect of the SIJ using a posterior approach. As the needle contacts firm tissues on the posterior aspect of the joint, position of the needle tip is checked using lateral fluoroscopy. In the lateral view, the needle tip position is manipulated to keep it in the anterior third of the SIJ and contrast is injected. Our criteria for accurate SIJ block, in posteroanterior (PA) view, is the injection of the contrast medium should outline the joint space and the contrast medium should be seen to travel cephalad along the joint line. In the lateral view, the contrast medium most densely outlines the parameter of the joint. We have utilized this method with good effect in approximately 30 cases over one year. Out of 30 cases, needle position and contrast spread was satisfactory in 28 and 27 cases, respectively. So satisfactory needle placement and contrast spread was in 93% and 87% cases. Pain relief of 80% or more after intra-articular injection of local anesthetic was seen in 50% (15 of 30) patients; pain relief of 50 - 79% was witnessed in 30% (9 of 30) patients. Thus, pain decreased 50% or more in 80% (24 of 30) of the joints. Out of 24 joints where we got satisfactory needle position and contrast spread, 23 joints got more than 50% relief. Thus, if needle position and contrast spread is satisfactory as per the criteria, pain relief of 50% or more was in 96% (23 of 24) of joints. There are few possible limitations with this study like difficulty to go up to the anterior third of the SIJ, it may be more painful as a narrow joint line has to be travelled in depth, sciatic numbness due to drug leak, or injuring the pelvic structure. Advantages of this method are that depth and level of the needle tip for a SIJ block is described for the more precise block. This will reduce false positive and false negative results, i.e., sensitivity and specificity of SIJ blocks and results for diagnostic blocks become more reliable. It will also reduce the chances of a case getting abandoned due to inappropriate contrast spread obscuring the fluoroscopic landmarks. As we know the depth of the needle, the chances of injuring pelvic structures become less and safety improves.
NASA Astrophysics Data System (ADS)
Li, Jiawen; Quirk, Bryden C.; Noble, Peter B.; Kirk, Rodney W.; Sampson, David D.; McLaughlin, Robert A.
2017-10-01
Transbronchial needle aspiration (TBNA) of small lesions or lymph nodes in the lung may result in nondiagnostic tissue samples. We demonstrate the integration of an optical coherence tomography (OCT) probe into a 19-gauge flexible needle for lung tissue aspiration. This probe allows simultaneous visualization and aspiration of the tissue. By eliminating the need for insertion and withdrawal of a separate imaging probe, this integrated design minimizes the risk of dislodging the needle from the lesion prior to aspiration and may facilitate more accurate placement of the needle. Results from in situ imaging in a sheep lung show clear distinction between solid tissue and two typical constituents of nondiagnostic samples (adipose and lung parenchyma). Clinical translation of this OCT-guided aspiration needle holds promise for improving the diagnostic yield of TBNA.
Litter type control on soil C and N stabilization dynamics in a temperate forest.
Hatton, Pierre-Joseph; Castanha, Cristina; Torn, Margaret S; Bird, Jeffrey A
2015-03-01
While plant litters are the main source of soil organic matter (SOM) in forests, the controllers and pathways to stable SOM formation remain unclear. Here, we address how litter type ((13) C/(15) N-labeled needles vs. fine roots) and placement-depth (O vs. A horizon) affect in situ C and N dynamics in a temperate forest soil after 5 years. Litter type rather than placement-depth controlled soil C and N retention after 5 years in situ, with belowground fine root inputs greatly enhancing soil C (x1.4) and N (x1.2) retention compared with aboveground needles. While the proportions of added needle and fine root-derived C and N recovered into stable SOM fractions were similar, they followed different transformation pathways into stable SOM fractions: fine root transfer was slower than for needles, but proportionally more of the remaining needle-derived C and N was transferred into stable SOM fractions. The stoichiometry of litter-derived C vs. N within individual SOM fractions revealed the presence at least two pools of different turnover times (per SOM fraction) and emphasized the role of N-rich compounds for long-term persistence. Finally, a regression approach suggested that models may underestimate soil C retention from litter with fast decomposition rates. © 2014 John Wiley & Sons Ltd.
Mechanics of anesthetic needle penetration into human sciatic nerve.
Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A
2018-06-06
Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.
Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound
NASA Astrophysics Data System (ADS)
Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.
2015-12-01
Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.
1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections
Marker, David R.; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.; Carrino, John A.; Fritz, Jan
2017-01-01
PURPOSE The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. METHODS A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. RESULTS Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. CONCLUSION 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus. PMID:28420598
1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.
Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan
2017-01-01
The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.
Positional calibration of an ultrasound image-guided robotic breast biopsy system.
Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob
2012-03-01
Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.
Reid, John A; Mollica, Peter A; Johnson, Garett D; Ogle, Roy C; Bruno, Robert D; Sachs, Patrick C
2016-06-07
The precision and repeatability offered by computer-aided design and computer-numerically controlled techniques in biofabrication processes is quickly becoming an industry standard. However, many hurdles still exist before these techniques can be used in research laboratories for cellular and molecular biology applications. Extrusion-based bioprinting systems have been characterized by high development costs, injector clogging, difficulty achieving small cell number deposits, decreased cell viability, and altered cell function post-printing. To circumvent the high-price barrier to entry of conventional bioprinters, we designed and 3D printed components for the adaptation of an inexpensive 'off-the-shelf' commercially available 3D printer. We also demonstrate via goal based computer simulations that the needle geometries of conventional commercially standardized, 'luer-lock' syringe-needle systems cause many of the issues plaguing conventional bioprinters. To address these performance limitations we optimized flow within several microneedle geometries, which revealed a short tapered injector design with minimal cylindrical needle length was ideal to minimize cell strain and accretion. We then experimentally quantified these geometries using pulled glass microcapillary pipettes and our modified, low-cost 3D printer. This systems performance validated our models exhibiting: reduced clogging, single cell print resolution, and maintenance of cell viability without the use of a sacrificial vehicle. Using this system we show the successful printing of human induced pluripotent stem cells (hiPSCs) into Geltrex and note their retention of a pluripotent state 7 d post printing. We also show embryoid body differentiation of hiPSC by injection into differentiation conducive environments, wherein we observed continuous growth, emergence of various evaginations, and post-printing gene expression indicative of the presence of all three germ layers. These data demonstrate an accessible open-source 3D bioprinter capable of serving the needs of any laboratory interested in 3D cellular interactions and tissue engineering.
NASA Astrophysics Data System (ADS)
Samboju, Vishal; Adams, Matthew; Salgaonkar, Vasant; Diederich, Chris J.; Cunha, J. Adam M.
2017-02-01
The speed of sound (SOS) for ultrasound devices used for imaging soft tissue is often calibrated to water, 1540 m/s1 , despite in-vivo soft tissue SOS varying from 1450 to 1613 m/s2 . Images acquired with 1540 m/s and used in conjunction with stereotactic external coordinate systems can thus result in displacement errors of several millimeters. Ultrasound imaging systems are routinely used to guide interventional thermal ablation and cryoablation devices, or radiation sources for brachytherapy3 . Brachytherapy uses small radioactive pellets, inserted interstitially with needles under ultrasound guidance, to eradicate cancerous tissue4 . Since the radiation dose diminishes with distance from the pellet as 1/r2 , imaging uncertainty of a few millimeters can result in significant erroneous dose delivery5,6. Likewise, modeling of power deposition and thermal dose accumulations from ablative sources are also prone to errors due to placement offsets from SOS errors7 . This work presents a method of mitigating needle placement error due to SOS variances without the need of ionizing radiation2,8. We demonstrate the effects of changes in dosimetry in a prostate brachytherapy environment due to patientspecific SOS variances and the ability to mitigate dose delivery uncertainty. Electromagnetic (EM) sensors embedded in the brachytherapy ultrasound system provide information regarding 3D position and orientation of the ultrasound array. Algorithms using data from these two modalities are used to correct bmode images to account for SOS errors. While ultrasound localization resulted in >3 mm displacements, EM resolution was verified to <1 mm precision using custom-built phantoms with various SOS, showing 1% accuracy in SOS measurement.
Althaus, C; Sundmacher, R
1993-08-01
Two technical difficulties have to be overcome in transscleral suture fixation of posterior chamber intraocular lenses (PCL) in the ciliary sulcus: first, exact needle penetration through the sulcus, and second, exact positioning of the PCL haptics in the sulcus. Incongruence of the two may lead to long-term complications by compression or even strangulation of ciliary processes. Intraocular endoscopy was used intraoperatively to visualize the site of needle penetration and the final location of the haptics in patients. It turned out that with our previously described standard techniques the precision was far less than anticipated. Thus, new technical ways had to be sought to improve the precision of positioning. In secondary implantation without perforating keratoplasty we achieved the best results when the needle was passed ab externo before opening the eye and before anterior vitrectomy, taking advantage of a precisely prepared sclerocorneal zone. Passing the needle ab externo in an already hypotonic eyeball gives much less precise results. In combination with perforating keratoplasty with an open-sky approach, needle penetration ab interno is reliable. Correct positioning of the PCL haptics is at least as difficult as correct needle penetration, a fact which up to now has mostly been ignored. In 33 consecutively operated eyes the technique of implantation and PCL design was varied under endoscopical control.(ABSTRACT TRUNCATED AT 250 WORDS)
Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A
2015-12-01
To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kao, Meng-Chun; Ting, Chien-Kun; Kuo, Wen-Chuan
2018-02-01
Incorrect placement of the needle causes medical complications in the epidural block, such as dural puncture or spinal cord injury. This study proposes a system which combines an optical coherence tomography (OCT) imaging probe with an automatic identification (AI) system to objectively identify the position of the epidural needle tip. The automatic identification system uses three features as image parameters to distinguish the different tissue by three classifiers. Finally, we found that the support vector machine (SVM) classifier has highest accuracy, specificity, and sensitivity, which reached to 95%, 98%, and 92%, respectively.
Seligman, Katherine M; Weiniger, Carolyn F; Carvalho, Brendan
2017-08-30
This study investigated the accuracy of a wireless handheld ultrasound with pattern recognition software that recognizes lumbar spine bony landmarks and measures depth to epidural space (Accuro, Rivanna Medical, Charlottesville, VA) (AU). AU measurements to epidural space were compared to Tuohy needle depth to epidural space (depth to loss of resistance at epidural placement). Data from 47 women requesting labor epidural analgesia were analyzed. The mean difference between depth to epidural space measured by AU versus needle depth was -0.61 cm (95% confidence interval, -0.79 to -0.44), with a standard deviation of 0.58 (95% confidence interval, 0.48-0.73). Using the AU-identified insertion point resulted in successful epidural placement at first attempt in 87% of patients, 78% without redirects.
CT guided interstitial therapy of pancreatic carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haaga, J.R.; Owens, D.B.; Kellermeyer, R.W.
1987-11-01
We describe the use of percutaneous CT guidance for localization and placement of /sup 192/Ir sources into a patient with pancreatic carcinoma. We have shown the feasibility of this procedure and the lack of complications which are probably due to minimal damage to tissue involved. Computed tomography is ideally suited for percutaneous implantation because it provides the most accurate method for needle placement within the abdomen.
Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C
2018-04-01
Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.
Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor
2008-06-01
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.
Coaxial needle insertion assistant with enhanced force feedback.
De Lorenzo, Danilo; Koseki, Yoshihiko; De Momi, Elena; Chinzei, Kiyoyuki; Okamura, Allison M
2013-02-01
Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user.
Hussein, Mohamed
2017-07-01
Accurate delivery of an injection into the intra-articular space of the knee is achieved in only two thirds of knees when using the standard anterolateral portal. The use of a modified full-flexion anterolateral portal provides a highly accurate, less painful, and more effective method for reproducible intra-articular injection without the need for ultrasonographic or fluoroscopic guidance in patients with dry osteoarthritis of the knee. The accuracy of needle placement was assessed in a prospective series of 140 consecutive injections in patients with symptomatic degenerative knee arthritis without clinical knee effusion. Procedural pain was determined using the Numerical Rating Scale. The accuracy rates of needle placement were confirmed with fluoroscopic imaging to document the dispersion pattern of injected contrast material. Using the standard anterolateral portal, 52 of 70 injections were confirmed to have been placed in the intra-articular space on the first attempt (accuracy rate, 74.2%). Using the modified full-flexion anterolateral portal, 68 of 70 injections were placed in the intra-articular space on the first attempt (accuracy rate, 97.1%; P = 0.000). This study revealed that using the modified full-flexion anterolateral portal for injections into the knee joint resulted in more accurate and less painful injections than those performed by the same orthopaedic surgeon using the standard anterolateral portal. In addition, the technique offered therapeutic delivery into the joint without the need for fluoroscopic confirmation. Therapeutic Level II.
Semicircular thermocouple needle depth gauge for cryoprocedures.
Pappenfort, R B
1981-06-01
A semicircular thermocouple needle depth gauge made of an aluminum alloy drilled with tracks at different angles to place thermocouple needles at various depths below the surface is described herein. Its shape offers definite advantages over circular jigs (templates) when doing cryoexperimentation and when used clinically. The material of which it is made is more durable than plastic. Grommets that firmly snap in place within the inner rim of the instrument permit accurate placement of liquid gas spray, cryoprobes, and other applicators directly over the thermocouple needle tips. This is of special importance when doing cryoexperiments. Furthermore, with this design, the advancing ice front and possible liquid gas runoff are more easily seen. By using both halves it is suitable for monitoring the temperature when freezing large tumors at two different sites and a different depths.
Transillumination for needle localization in the larynx.
Hoffman, Henry T; Dailey, Seth H; Bock, Jonathan M; Thibeault, Susan L; McCulloch, Timothy M
2015-10-01
Transillumination through laryngeal soft tissue may be used to direct percutaneous transcricothyroid membrane subepithelial needle placement in the larynx. Cadaver simulation (canine and human). Lighted devices, including sialendoscopes and fiberoptic cables, were tested as transilluminating obturators in trocars and needles through multiple studies to identify appropriate illumination, monitoring, and equipment for successful localization of needle/trocar tips placed within laryngeal tissue. Lighted 250-micron fiberoptic cables within 23-gauge needles were successfully placed percutaneously through the cricothyroid membrane and maneuvered submucosally into Reinke's space, the midlateral vocal fold, and through the thyroarytenoid gap with monitoring via flexible transnasal laryngoscopy. Technical adaptations in the course of study permitted successful simulation of clinical use in full cadaver study for accurate injection laryngoplasty, confirmed by laryngeal dissection following collagen injection. Small caliber fiberoptic cables are useful as transilluminating obturators to accurately direct needle position within laryngeal tissue. Clinical application of this new technique is anticipated to improve the accuracy of percutaneous needle localization in the larynx, as well as to assist in directed instrumentation of the larynx from an external approach. N/A. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Comparison of Spinal Needle Deflection in a Ballistic Gel Model.
Rand, Ethan; Christolias, George; Visco, Christopher; R Singh, Jaspal
2016-10-01
Percutaneous diagnostic and therapeutic procedures are commonly used in the treatment of spinal pain. The success of these procedures depends on the accuracy of needle placement, which is influenced by needle size and shape. The purpose of this study is to examine and quantify the deviation of commonly used spinal needles based on needle tip design and gauge, using a ballistic gel tissue simulant. Six needles commonly used in spinal procedures (Quincke, Short Bevel, Chiba, Tuohy, Hustead, Whitacre) were selected for use in this study. Ballistic gel samples were made in molds of two depths, 40mm and 80 mm. Each needle was mounted in a drill press to ensure an accurate needle trajectory. Distance of deflection was recorded for each needle. In comparing the mean deflection of 22 gauge needles of all types at 80 mm of depth, deflection was greatest among beveled needles [Short Bevel (9.96 ± 0.77 mm), Quincke (8.89 ± 0.17 mm), Chiba (7.71 ± 1.16 mm)], moderate among epidural needles [Tuohy (7.64 ± 0.16 mm) and least among the pencil-point needles [Whitacre (0.73 ± 0.34 mm)]. Increased gauge (25 g) led to a significant increase in deflection among beveled needles. The direction of deflection was away from the bevel with Quincke, Chiba and Short Beveled needles and toward the bevel of the Tuohy and Hustead needles. Deflection of the Whitacre pencil-point needle was minimal. There is clinical utility in knowing the relative deflection of various needle tips. When a procedure requires a needle to be steered around obstacles, or along non-collinear targets, the predictable and large amount of deflection obtained through use of a beveled spinal needle may prove beneficial.
Comparison of Spinal Needle Deflection in a Ballistic Gel Model
Rand, Ethan; Christolias, George; Visco, Christopher; R. Singh, Jaspal
2016-01-01
Background Percutaneous diagnostic and therapeutic procedures are commonly used in the treatment of spinal pain. The success of these procedures depends on the accuracy of needle placement, which is influenced by needle size and shape. Objectives The purpose of this study is to examine and quantify the deviation of commonly used spinal needles based on needle tip design and gauge, using a ballistic gel tissue simulant. Materials and Methods Six needles commonly used in spinal procedures (Quincke, Short Bevel, Chiba, Tuohy, Hustead, Whitacre) were selected for use in this study. Ballistic gel samples were made in molds of two depths, 40mm and 80 mm. Each needle was mounted in a drill press to ensure an accurate needle trajectory. Distance of deflection was recorded for each needle. Results In comparing the mean deflection of 22 gauge needles of all types at 80 mm of depth, deflection was greatest among beveled needles [Short Bevel (9.96 ± 0.77 mm), Quincke (8.89 ± 0.17 mm), Chiba (7.71 ± 1.16 mm)], moderate among epidural needles [Tuohy (7.64 ± 0.16 mm) and least among the pencil-point needles [Whitacre (0.73 ± 0.34 mm)]. Increased gauge (25 g) led to a significant increase in deflection among beveled needles. The direction of deflection was away from the bevel with Quincke, Chiba and Short Beveled needles and toward the bevel of the Tuohy and Hustead needles. Deflection of the Whitacre pencil-point needle was minimal. Conclusions There is clinical utility in knowing the relative deflection of various needle tips. When a procedure requires a needle to be steered around obstacles, or along non-collinear targets, the predictable and large amount of deflection obtained through use of a beveled spinal needle may prove beneficial. PMID:27847693
Development and validation of a new guidance device for lateral approach stereotactic breast biopsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, K.; Kornecki, A.; Bax, J.
2009-06-15
Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authorsmore » present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.« less
Creating and evaluating a data-driven curriculum for central venous catheter placement.
Duncan, James R; Henderson, Katherine; Street, Mandie; Richmond, Amy; Klingensmith, Mary; Beta, Elio; Vannucci, Andrea; Murray, David
2010-09-01
Central venous catheter placement is a common procedure with a high incidence of error. Other fields requiring high reliability have used Failure Mode and Effects Analysis (FMEA) to prioritize quality and safety improvement efforts. To use FMEA in the development of a formal, standardized curriculum for central venous catheter training. We surveyed interns regarding their prior experience with central venous catheter placement. A multidisciplinary team used FMEA to identify high-priority failure modes and to develop online and hands-on training modules to decrease the frequency, diminish the severity, and improve the early detection of these failure modes. We required new interns to complete the modules and tracked their progress using multiple assessments. Survey results showed new interns had little prior experience with central venous catheter placement. Using FMEA, we created a curriculum that focused on planning and execution skills and identified 3 priority topics: (1) retained guidewires, which led to training on handling catheters and guidewires; (2) improved needle access, which prompted the development of an ultrasound training module; and (3) catheter-associated bloodstream infections, which were addressed through training on maximum sterile barriers. Each module included assessments that measured progress toward recognition and avoidance of common failure modes. Since introducing this curriculum, the number of retained guidewires has fallen more than 4-fold. Rates of catheter-associated infections have not yet declined, and it will take time before ultrasound training will have a measurable effect. The FMEA provided a process for curriculum development. Precise definitions of failure modes for retained guidewires facilitated development of a curriculum that contributed to a dramatic decrease in the frequency of this complication. Although infections and access complications have not yet declined, failure mode identification, curriculum development, and monitored implementation show substantial promise for improving patient safety during placement of central venous catheters.
Cadaveric and Ultrasonographic Validation of Needling Placement in the Cervical Multifidus Muscle.
Fernández-de-Las-Peñas, César; Mesa-Jiménez, Juan A; Paredes-Mancilla, Jose A; Koppenhaver, Shane L; Fernández-Carnero, Samuel
2017-06-01
The aim of this study was to determine if a needle is able to reach the cervical multifidus during the application of dry needling or acupuncture. Dry needling and ultrasound imaging of cervical multifidi was conducted on 5 patients (age: 32 ± 5 years) with mechanical neck pain and on 2 fresh cadavers (age: 64 ± 1 years). Dry needling was done using a needle of 40 mm in length inserted perpendicular to the skin about 1 cm lateral to the spinous process at C3-C4. The needle was advanced from a posterior to anterior direction into the cervical multifidus with a slight inferior-medial angle (approximately 10°) to reach the vertebra lamina. For the cadaveric study, the multifidus was isolated by carefully resecting the superficial posterior cervical muscles: trapezius, splenius, and semispinalis. For the ultrasonographic study, a convex transducer was placed transversely over C3-C4 after the insertion of the needle into the muscle. The results of both the cadaveric and ultrasonic studies found that the needle does pierce the cervical multifidus muscle during insertion and that the tip of the needle rests properly against the vertebral laminae, thereby guarding the sensitive underlying spinal structures from damage. This anatomical and ultrasound imaging study supports that dry needling of the cervical multifidus could be conducted clinically. Copyright © 2017. Published by Elsevier Inc.
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement
Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor
2010-01-01
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608
Kalman filter-based EM-optical sensor fusion for needle deflection estimation.
Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan
2018-04-01
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.
Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine
NASA Astrophysics Data System (ADS)
Rasoulian, Abtin; Rohling, Robert N.; Abolmaesumi, Purang
2012-02-01
The placement of an epidural needle is among the most difficult regional anesthetic techniques. Ultrasound has been proposed to improve success of placement. However, it has not become the standard-of-care because of limitations in the depictions and interpretation of the key anatomical features. We propose to augment the ultrasound images with a registered statistical shape model of the spine to aid interpretation. The model is created with a novel deformable group-wise registration method which utilizes a probabilistic approach to register groups of point sets. The method is compared to a volume-based model building technique and it demonstrates better generalization and compactness. We instantiate and register the shape model to a spine surface probability map extracted from the ultrasound images. Validation is performed on human subjects. The achieved registration accuracy (2-4 mm) is sufficient to guide the choice of puncture site and trajectory of an epidural needle.
Risher, D W; Zhang, X; Kostarczyk, E; Gokin, A P; Honda, C N; Giesler, G J
1997-04-25
We developed a relatively inexpensive method for stereotaxic placement of electrodes or needles in the brains of monkeys. Steel balls were affixed to the skulls of monkeys. These balls served as fiducial markers and were also used as points at which the monkey's skull was held in a modified stereotaxic apparatus. Computed tomography (CT) was used to establish the location of an injection target with respect to the fiducial markers. A computer program related the CT coordinates to stereotaxic coordinates. These were used to direct an electrode marker toward a target in the hypothalamus. With the marker left in place, the monkey was removed from the stereotaxic frame and a second CT scan was performed. Corrections for errors in marker placement were made and retrograde tracers were injected. This procedure was found to be more accurate and reliable than conventional stereotaxic procedures. The accuracy and repeatability of the technique were also established using a phantom model of a monkey's skull. Two important advantages of this method are that animals can be repeatedly placed into the stereotaxic frame in precisely the same position and that there are many opportunities during the procedure to check for and correct errors.
Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F
2014-01-01
We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p < 0.001). Day 30 values were 16.6 Gy less vs. 2.2 Gy more than planned, respectively (p = 0.028). Day 1 target V100 was 6.3% less than planned with standard vs. 2.8% less for HELP (p < 0.001). There was no significant difference between the urethral and rectal concordance (all p > 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Objective assessment of operator performance during ultrasound-guided procedures.
Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R
2011-09-01
Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.
NASA Astrophysics Data System (ADS)
Rodgers, J.; Tessier, D.; D'Souza, D.; Leung, E.; Hajdok, G.; Fenster, A.
2016-04-01
High-dose-rate (HDR) interstitial brachytherapy is often included in standard-of-care for gynaecological cancers. Needles are currently inserted through a perineal template without any standard real-time imaging modality to assist needle guidance, causing physicians to rely on pre-operative imaging, clinical examination, and experience. While two-dimensional (2D) ultrasound (US) is sometimes used for real-time guidance, visualization of needle placement and depth is difficult and subject to variability and inaccuracy in 2D images. The close proximity to critical organs, in particular the rectum and bladder, can lead to serious complications. We have developed a three-dimensional (3D) transrectal US system and are investigating its use for intra-operative visualization of needle positions used in HDR gynaecological brachytherapy. As a proof-of-concept, four patients were imaged with post-insertion 3D US and x-ray CT. Using software developed in our laboratory, manual rigid registration of the two modalities was performed based on the perineal template's vaginal cylinder. The needle tip and a second point along the needle path were identified for each needle visible in US. The difference between modalities in the needle trajectory and needle tip position was calculated for each identified needle. For the 60 needles placed, the mean trajectory difference was 3.23 +/- 1.65° across the 53 visible needle paths and the mean difference in needle tip position was 3.89 +/- 1.92 mm across the 48 visible needles tips. Based on the preliminary results, 3D transrectal US shows potential for the development of a 3D US-based needle guidance system for interstitial gynaecological brachytherapy.
Experimental platform for intra-uterine needle placement procedures
NASA Astrophysics Data System (ADS)
Madjidi, Yashar; Haidegger, Tamás.; Ptacek, Wolfgang; Berger, Daniel; Kirisits, Christian; Kronreif, Gernot; Fichtinger, Gabor
2013-03-01
A framework has been investigated to enable a variety of comparative studies in the context of needle-based gynaecological brachytherapy. Our aim was to create an anthropomorphic phantom-based platform. The three main elements of the platform are the organ model, needle guide, and needle drive. These have been studied and designed to replicate the close environment of brachytherapy treatment for cervical cancer. Key features were created with the help of collaborating interventional radio-oncologists and the observations made in the operating room. A phantom box, representing the uterus model, has been developed considering available surgical analogies and operational limitations, such as organs at risk. A modular phantom-based platform has been designed and prototyped with the capability of providing various boundary conditions for the target organ. By mimicking the female pelvic floor, this framework has been used to compare a variety of needle insertion techniques and configurations for cervical and uterine interventions. The results showed that the proposed methodology is useful for the investigation of quantifiable experiments in the intraabdominal and pelvic regions.
Methods for prostate stabilization during transperineal LDR brachytherapy.
Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan
2008-03-21
In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and training simulators.
... Home Current Issue Past Issues Special Section CAM Acupuncture From Ancient Practice to Modern Science Past Issues / ... percent of U.S. adults use acupuncture. What Is Acupuncture? Dr. Adeline Ge adjusts placement of acupuncture needles ...
Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.
Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G
2013-09-01
To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
[Radiofrequency ablation of hepatocellular carcinoma].
Widmann, Gerlig; Schullian, Peter; Bale, Reto
2013-03-01
Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.
Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.
Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata
2017-01-01
A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.
Reina, M A; López, A; Villanueva, M C; De Andrés, J A; Martín, S
2005-05-01
To assess the possibility of puncturing nerve roots in the cauda equina with spinal needles with different point designs and to quantify the number of axons affected. We performed in vitro punctures of human nerve roots taken from 3 fresh cadavers. Twenty punctures were performed with 25-gauge Whitacre needles and 40 with 25-gauge Quincke needles; half the Quincke needle punctures were carried out with the point perpendicular to the root and the other half with the point parallel to it. The samples were studied by optical and scanning electron microscopy. The possibility of finding the needle orifece inserted inside the nerve was assessed. On a photographic montage, we counted the number of axons during a hypothetical nerve puncture. Nerve roots used in this study were between 1 and 2.3 mm thick, allowing the needle to penetrate the root in the 52 samples studied. The needle orifice was never fully located inside the nerve in any of the samples. The numbers of myelinized axons affected during nerve punctures 0.2 mm deep were 95, 154, and 81 for Whitacre needles, Quincke needles with the point held perpendicular, or the same needle type held parallel, respectively. During punctures 0.5 mm deep, 472, 602, and 279 were affected for each puncture group, respectively. The differences in all cases were statistically significant. It is possible to achieve intraneural puncture with 25-gauge needles. However, full intraneural placement of the orifice of the needle is unlikely. In case of nerve trauma, the damage could be greater if puncture is carried out with a Quincke needle with the point inserted perpendicular to the nerve root.
Advances in local ablation of malignant liver lesions
Eisele, Robert M
2016-01-01
Local ablation of liver tumors matured during the recent years and is now proven to be an effective tool in the treatment of malignant liver lesions. Advances focus on the improvement of local tumor control by technical innovations, individual selection of imaging modalities, more accurate needle placement and the free choice of access to the liver. Considering data found in the current literature for conventional local ablative treatment strategies, virtually no single technology is able to demonstrate an unequivocal superiority. Hints at better performance of microwave compared to radiofrequency ablation regarding local tumor control, duration of the procedure and potentially achievable larger size of ablation areas favour the comparably more recent treatment modality; image fusion enables more patients to undergo ultrasound guided local ablation; magnetic resonance guidance may improve primary success rates in selected patients; navigation and robotics accelerate the needle placement and reduces deviation of needle positions; laparoscopic thermoablation results in larger ablation areas and therefore hypothetically better local tumor control under acceptable complication rates, but seems to be limited to patients with no, mild or moderate adhesions following earlier surgical procedures. Apart from that, most techniques appear technically feasible, albeit demanding. Which technology will in the long run become accepted, is subject to future work. PMID:27099433
Interventional robotic systems: Applications and technology state-of-the-art
CLEARY, KEVIN; MELZER, ANDREAS; WATSON, VANCE; KRONREIF, GERNOT; STOIANOVICI, DAN
2011-01-01
Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere. PMID:16754193
Needle Thoracostomy: Does Changing Needle Length and Location Change Patient Outcome?
Weichenthal, Lori A; Owen, Scott; Stroh, Geoffory; Ramos, John
2018-06-01
Needle thoracostomy (NT) is a common prehospital intervention for patients in extremis or cardiac arrest due to trauma. The purpose of this study is to compare outcomes, efficacy, and complications after a change in policy related to NT in a four-county Emergency Medical Services (EMS) system with a catchment area of greater than 1.6 million people. This is a before and after observational study of all patients who had NT performed in the Central California (USA) EMS system. The before, anterior midclavicular line (MCL) group consisted of all patients who underwent NT from May 7, 2007 through February 28, 2013. The after, midaxillary line (MAL) axillary group consisted of all patients who underwent NT from March 1, 2013 through January 30, 2016, after policy revisions changed the timing, needle size, and placement location for NT. All prehospital and hospital records where NT was performed were queried for demographics, mechanism of injury, initial status and post-NT clinical change, reported complications, and final outcome. The trauma registry was accessed to obtain Injury Severity Scores (ISS). Information was manually abstracted by study investigators and examined utilizing univariate and multivariate analyses. Three-hundred and five trauma patients treated with NT were included in this study, of which, 169 patients (the MCL group) were treated with a 14-guage intravenous (IV) catheter at least 5.0-cm long at the second intercostal space (ICS), MCL after being placed in the ambulance; and 136 patients (the MAL group) were treated with a 10-guage IV catheter at least 9.5-cm long at the fifth ICS, MAL on scene. The mean ISS was lower in the MAL cohort (64.5 versus 69.2; P=.007). The mortality rate was 79% in both groups. The multivariate model with regard to survival supported that a lower ISS (P<.001) and reported clinical change after NT (P=.003) were significant indicators of survival. No complications from NT were reported. Changing the timing, length of needle, and location of placement did not change mortality in patients requiring NT. Needle thoracostomy was used more frequently after the change in policy, and the MAL cohort was less injured. No increase in reported complications was noted. WeichenthalLA, OwenS, StrohG, RamosJ. Needle thoracostomy: does changing needle length and location change patient outcome? Prehosp Disaster Med. 2018;33(3):237-244.
Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.
Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A
2012-06-01
Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.
Enabling image fusion for a CT guided needle placement robot
NASA Astrophysics Data System (ADS)
Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.
2017-03-01
Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.
NASA Astrophysics Data System (ADS)
Honarvar, Mohammad
Needle-based intervention insertion is one of the common surgical techniques used in many diagnostic and therapeutic percutaneous procedures. The success of such procedures highly depends on the accuracy of needle placement at target locations. An active needle has the potential to enhance the accuracy of needle placement as well as to improve clinical outcome. Bending forces provided by the attached actuators can assist the maneuverability in order to reach the targets following a desired trajectory. There are three major research parts in the development of active needle project in the Composites Laboratory of Temple University. They are thermomechanical characterization of shape memory alloy (SMA) or Nitinol as an actuator for smart needle, mechanical modeling and design of smart needles, and study of tissue needle interaction. The characterization of SMA is the focus of this dissertation. Unique thermomechanical properties of Nitinol known as shape memory effect and superelasticity make it applicable for different fields such as biomedical, structural and aerospace engineering. These unique behaviors are due to the comparatively large amount of recoverable strain which is being produced in a martensitic phase transformation. However, under certain ranges of stresses and temperatures, Nitinol wires exhibit unrecovered strain (also known as residual strain); which limits their applicability. Therefore, for applications that rely on the strain response in repetitive loading and unloading cycles, it is important to understand the generation of the unrecovered strain in the Nitinol wires. In this study, the unrecovered strain of Nitinol wires with various diameters was investigated, using two experimental approaches: constant stress and uniaxial tensile tests. Moreover, a critical range of stress was found beyond which the unrecovered strain was negligible at temperatures of 70 to 80°C depending on the wire diameter. Wire diameters varied from 0.10 to 0.29 mm were tested and different ranges of critical stress were found for different wire diameters. The transformation temperatures of different wire diameters at zero stress have been achieved by performing the Differential Scanning Calorimetry (DSC) test. The actuation force created by Nitinol wire is measured through constant strain experiment. X-Ray Diffraction (XRD) study was also performed to investigate the phase of Nitinol wires under various thermomechanical loading conditions. In summary, the effect of wire diameter on the required critical stresses to avoid the unrecovered strain between first and second cycle of heating and cooling are presented and the results of both mechanical tests are justified by the results obtained from the XRD study.
Minimum anesthetic volume in regional anesthesia by using ultrasound-guidance.
Di Filippo, Alessandro; Falsini, Silvia; Adembri, Chiara
2016-01-01
The ultrasound guidance in regional anesthesia ensures the visualization of needle placement and the spread of Local Anesthetics. Over the past few years there was a substantial interest in determining the Minimum Effective Anesthetic Volume necessary to accomplish surgical anesthesia. The precise and real-time visualization of Local Anesthetics spread under ultrasound guidance block may represent the best requisite for reducing Local Anesthetics dose and Local Anesthetics-related effects. We will report a series of studies that have demonstrated the efficacy of ultrasound guidance blocks to reduce Local Anesthetics and obtain surgical anesthesia as compared to block performed under blind or electrical nerve stimulation technique. Unfortunately, the results of studies are widely divergent and not seem to indicate a dose considered effective, for each block, in a definitive way; but it is true that, through the use of ultrasound guidance, it is possible to reduce the dose of anesthetic in the performance of anesthetic blocks. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Peris-Celda, Maria; Graziano, Francesca; Russo, Vittorio; Mericle, Robert A; Ulm, Arthur J
2013-11-01
Foramen ovale (FO) puncture allows for trigeminal neuralgia treatment, FO electrode placement, and selected biopsy studies. The goals of this study were to demonstrate the anatomical basis of complications related to FO puncture, and provide anatomical landmarks for improvement of safety, selective lesioning of the trigeminal nerve (TN), and optimal placement of electrodes. Both sides of 50 dry skulls were studied to obtain the distances from the FO to relevant cranial base references. A total of 36 sides from 18 formalin-fixed specimens were dissected for Meckel cave and TN measurements. The best radiographic projection for FO visualization was assessed in 40 skulls, and the optimal trajectory angles, insertion depths, and topographies of the lesions were evaluated in 17 specimens. In addition, the differences in postoperative pain relief after the radiofrequency procedure among different branches of the TN were statistically assessed in 49 patients to determine if there was any TN branch less efficiently targeted. Most severe complications during FO puncture are related to incorrect needle placement intracranially or extracranially. The needle should be inserted 25 mm lateral to the oral commissure, forming an approximately 45° angle with the hard palate in the lateral radiographic view, directed 20° medially in the anteroposterior view. Once the needle reaches the FO, it can be advanced by 20 mm, on average, up to the petrous ridge. If the needle/radiofrequency electrode tip remains more than 18 mm away from the midline, injury to the cavernous carotid artery is minimized. Anatomically there is less potential for complications when the needle/radiofrequency electrode is advanced no more than 2 mm away from the clival line in the lateral view, when the needle pierces the medial part of the FO toward the medial part of the trigeminal impression in the petrous ridge, and no more than 4 mm in the lateral part. The 40°/45° inferior transfacial-20° oblique radiographic projection visualized 96.2% of the FOs in dry skulls, and the remainder were not visualized in any other projection of the radiograph. Patients with V1 involvement experienced postoperative pain more frequently than did patients with V2 or V3 involvement. Anatomical targeting of V1 in specimens was more efficiently achieved by inserting the needle in the medial third of the FO; for V2 targeting, in the middle of the FO; and for V3 targeting, in the lateral third of the FO. Knowledge of the extracranial and intracranial anatomical relationships of the FO is essential to understanding and avoiding complications during FO puncture. These data suggest that better radiographic visualization of the FO can improve lesioning accuracy depending on the part of the FO to be punctured. The angles and safety distances obtained may help the neurosurgeon minimize complications during FO puncture and TN lesioning.
Endpoint Accuracy in Manual Control of a Steerable Needle.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2017-02-01
To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Optimal actuator placement in adaptive precision trusses
NASA Technical Reports Server (NTRS)
Baycan, C. M.; Utku, S.; Das, S. K.; Wada, B. K.
1992-01-01
Actuator placement in adaptive truss structures is to cater to two needs: displacement control of precision points and preloading the elements to overcome joint slackness. Due to technological and financial considerations, the number of actuators available is much less than the degrees of freedom of precision points to be controlled and the degree of redundancy of the structure. An approach for optimal actuator location is outlined. Test cases to demonstrate the effectiveness of the scheme are applied to the Precision Segmented Reflector Truss.
Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance
Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter
2010-01-01
Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152
Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong
2016-01-01
The “robotic-assisted liver tumor coagulation therapy” (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles’ operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot’s movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle “collision-free reachable workspace” (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy, significantly reduce the surgeon’s workload, and is especially helpful for an inexperienced surgeon. The methodology should be easy to adapt in other body parts. PMID:26982341
Song, Shi-Lin
2013-04-01
To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.
Brewer, Zachary E; Fann, Hutchinson C; Ogden, W David; Burdon, Thomas A; Sheikh, Ahmad Y
2016-01-01
It is speculated that, in operative environments, real-time visualization of the trainee's viewpoint by the instructor may improve performance and teaching efficacy. We hypothesized that introduction of a wearable surgical visualization system allowing the instructor to visualize otherwise "blind" areas in the operative field could improve trainee performance in a simulated operative setting. A total of 11 surgery residents (4 in general surgery training and 7 in an integrated 6-year cardiothoracic surgery program) participated in the study. Google (Mountain View, CA) Glass hardware running proprietary software from CrowdOptic (San Francisco, CA) was utilized for creation of the wearable surgical visualization system. Both the learner and trainer wore the system, and video was streamed from the learner's system in real time to the trainer, who directed the learner to place needles in a simulated operative field. Subjects placed a total of 5 needles in each of 4 quadrants. A composite error score was calculated based on the accuracy of needle placement in relation to the intended needle trajectories as described by the trainer. Time to task completion (TTC) was also measured and participants completed an exit questionnaire. All residents completed the protocol tasks and the survey. Introduction of the wearable surgical visualization system did not affect mean time to task completion (278 ± 50 vs. 282 ± 69 seconds, p = NS). However, mean composite error score fell significantly once the wearable system was deployed (18 ± 5 vs. 15 ± 4, p < 0.05), demonstrating improved accuracy of needle placement. Most of the participants deemed the device unobtrusive, easy to operate, and useful for communication and instruction. This study suggests that wearable surgical visualization systems allowing for adoption of the learner's perspective may be a useful educational adjunct in the training of surgeons. Further evaluations of the efficacy of wearable technology in the operating room environment are warranted. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Fluoroscopically Guided Epidural Injections of the Cervical and Lumbar Spine.
Shim, Euddeum; Lee, Joon Woo; Lee, Eugene; Ahn, Joong Mo; Kang, Yusuhn; Kang, Heung Sik
2017-01-01
Advances in imaging and the development of injection techniques have enabled spinal intervention to become an important tool in managing chronic spinal pain. Epidural steroid injection (ESI) is one of the most widely used spinal interventions; it directly delivers drugs into the epidural space to relieve pain originating from degenerative spine disorders-central canal stenoses and neural foraminal stenoses-or disk herniations. Knowledge of the normal anatomy of the epidural space is essential to perform an effective and safe ESI and to recognize possible complications. Although computed tomographic (CT) or combined CT-fluoroscopic guidance has been increasingly used in ESI, conventional fluoroscopic guidance is generally performed. In ESI, drugs are delivered into the epidural space by interlaminar or transforaminal routes in the cervical spine or by interlaminar, transforaminal, or caudal routes in the lumbar spine. Epidurography is usually performed before drug delivery to verify the proper position of the needle in the epidural space. A small amount of contrast agent is injected with fluoroscopic guidance. Familiarity with the findings on a typical "true" epidurogram (demonstrating correct needle placement in the epidural space) permits proper performance of ESI. Findings on "false" epidurograms (demonstrating incorrect needle placement) include muscular staining and evidence of intravascular injection, inadvertent facet joint injection, dural puncture, subdural injection, and intraneural or intradiscal injection. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on December 22, 2016.
NASA Astrophysics Data System (ADS)
Susanti, Hesty; Suprijanto, Kurniadi, Deddy
2018-02-01
Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and ultrasound enhanced (echogenic) needle.
Mathematics Placement at the University of Illinois
ERIC Educational Resources Information Center
Ahlgren Reddy, Alison; Harper, Marc
2013-01-01
Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…
A blanching technique for intradermal injection of the hyaluronic acid Belotero.
Micheels, Patrick; Sarazin, Didier; Besse, Stéphanie; Sundaram, Hema; Flynn, Timothy C
2013-10-01
With the proliferation of dermal fillers in the aesthetic workplace have come instructions from various manufacturers regarding dermal placement. Determination of injection needle location in the dermis has in large part been based on physician expertise, product and needle familiarity, and patient-specific skin characteristics. An understanding of the precise depth of dermal structures may help practitioners improve injection specificity. Unlike other dermal fillers that suggest intradermal and deep dermal injection planes, a new hyaluronic acid with a cohesive polydensified matrix may be more appropriate for the superficial dermis because of its structure and its high degree of integration into the dermis. To that end, the authors designed a small study to quantify the depth of the superficial dermis by means of ultrasound and histology. Using ultrasound resources, the authors determined the depths of the epidermis, the dermis, and the reticular dermis in the buttocks of six patients; the authors then extrapolated the depth of the superficial reticular dermis. Histologic studies of two of the patients showed full integration of the product in the reticular dermis. Following determination of injection depths and filler integration, the authors describe a technique ("blanching") for injection of the cohesive polydensified matrix hyaluronic acid into the superficial dermis. At this time, blanching is appropriate only for injection of the cohesive polydensified matrix hyaluronic acid known as Belotero Balance in the United States, although it may have applications for other hyaluronic acid products outside of the United States.
Franz, Alfred Michael; Seitel, Alexander; Bopp, Nasrin; Erbelding, Christian; Cheray, Dominique; Delorme, Stefan; Grünwald, Frank; Korkusuz, Hüdayi; Maier-Hein, Lena
2017-06-01
Percutaneous radiofrequency ablation (RFA) of thyroid nodules is an alternative to surgical resection that offers the benefits of minimal scars for the patient, lower complication rates, and shorter treatment times. Ultrasound (US) is the preferred modality for guiding these procedures. The needle is usually kept within the US scanning plane to ensure needle visibility. However, this restricts flexibility in both transducer and needle movement and renders the procedure difficult, especially for inexperienced users. Existing navigation solutions often involve electromagnetic (EM) tracking, which requires placement of an external field generator (FG) in close proximity of the intervention site in order to avoid distortion of the EM field. This complicates the clinical workflow as placing the FG while ensuring that it neither restricts the physician's workspace nor affects tracking accuracy is awkward and time-consuming. The EchoTrack concept overcomes these issues by combining the US probe and the EM FG in one modality, simultaneously providing both real-time US and tracking data without requiring the placement of an external FG for tracking. We propose a system and workflow to use EchoTrack for RFA of thyroid nodules. According to our results, the overall error of the EchoTrack system resulting from errors related to tracking and calibration is below 2 mm. Navigated thyroid RFA with the proposed concept is clinically feasible. Motion of internal critical structures relative to external markers can be up to several millimeters in extreme cases. The EchoTrack concept with its simple setup, flexibility, improved needle visualization, and additional guidance information has high potential to be clinically used for thyroid RFA.
A new technical contribution for ultrasound-guided injections of sacro-iliac joints.
Migliore, A; Bizzi, E; Massafra, U; Vacca, F; Martin-Martin, L S; Granata, M; Tormenta, S
2010-05-01
Sacroiliac joint (SIJ) represents a difficult location for local therapies, as intra-articular injections may be hard to execute, especially in particular conditions such as chronic inflammatory diseases. However, in selected patients, local therapies may be considered. Some recent studies demonstrated the feasibility of ultrasound (US)-guided injection of SIJ, but still a complete explanation and definition of the technique is needed. Seven patients, four males and 3 females, affected by mono or bilateral sacroiliitis entered the study. Each patient received 40 mg of acetonide triamcinolone for each SIJ, intra articular (IA) US-guided injection. The technical originality proposed in this study consists in the spinal needle insertion in the middle of the cranial long side of the linear transducer with an orientation of about 10 degrees, determining shorter needle insertion for reaching joint space and consequently probably granting lesser pain and traumatism for patients. A total of 22 injections was performed. The longer follow-up time obtained was 18 months in 3 patients. All patients reached at least a 6 month follow-up. All patients reported an amelioration in pain that lasted for at least 6 months. No systemic adverse events were reported or observed. Complete visualization of SIJ and of needle placement was performed by US imaging, while compound proper injection was also visualized by Color-Doppler US imaging. Actually, sacroiliac joint intraarticular injections are often performed under fluoroscopy or Computerized Tomography guidance. Such techniques present several limitations, especially for repeated injections, such as the use of ionizing radiations, the need of a contrast agent and the direct and indirect costs connected. US guidance in IA SIJ injections may represent an easily repeatable imaging technique for needle placement and a precious tool for detecting inflammatory activity of the joint.
Finite element analyses of a dual actuated prototype of a smart needle
NASA Astrophysics Data System (ADS)
Konh, Bardia; Podder, Tarun K.
2017-04-01
Brachytherapy is one of the most effective modalities for treating early stage prostate cancer. In this procedure, radioactive seeds are being placed in the prostate to kill the tumorous cells. Inaccurate placement of seeds can underdose the tumor and dangerously overdose the critical structures (urethra, rectum, bladder) and adjacent healthy tissues. It is very difficult, if not impossible, for the surgeons to compensate the needle misplacement errors while using the conventional passive straight needles. The smart needles actuated by shape memory alloy (SMA) wires are being developed to provide more actuation and control for the surgeons to achieve more geometric conformity. In our recent work, a prototype of a smart needle was developed where not only the actuation of SMA wires were incorporated, but also shape memory polymers (SMPs) were included in the design introducing a soft joint element to further assist the flexibility of the active surgical needles. The additional actuation of shape memory polymers provided the capability of reaching much high flexibility that was not achievable before. However, there are some disadvantages using this active SMP component compared to a passive Nylon joint component that are discussed in this work. The utilization of a heated SMP as a soft joint showed about 20% improvement in the final needle tip deflection. This work presents the finite element studies of the developed prototype. A finite element model that could accurately predict the behavior of the smart needle could be very valuable in analyzing and optimizing the future novel designs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, Maxence, E-mail: M.E.P.Borot@um
Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensorsmore » each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position measurements was equal to 0.79 mm(0.37 mm). The update rate and latency of the FBG-based needle position measurement were 100 and 300 ms, respectively. Conclusions: The FBG-based needle tracking procedure proposed in this paper is able to determine the position of the complete needle, under MR-imaging, with better accuracy and precision, higher update rate, and lower latency compared to current MR-based needle localization methods. This system would be eligible for MR-guided brachytherapy, in particular, for an improved needle guidance and reconstruction.« less
Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne
2018-05-29
Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).
Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut; Mostbeck, Gerhard H
2011-01-01
Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
A technique for open trocar placement in laparoscopic surgery using the umbilical cicatrix tube.
Lal, Pawanindra; Sharma, R; Chander, R; Ramteke, V K
2002-09-01
Increasingly the open method for placement of the initial or first trocar is replacing the conventional technique with the Veress needle. Indeed, it is preferred because it affords peritoneal access under direct vision. A number of methods have been described in the literature using a variety of approaches and different instruments. We describe a method of open trocar placement in the supra- or subumbilical region that follows a stepwise procedure and employs specific instruments sequentially, while utilizing the umbilical cicatrix pillar or tube. This technique has been done in 525 cases with no complications or port site hernias. This is a simple technique that is safe and easy to learn. It can be performed rapidly and is a reliable method for the insertion of the first port under vision.
Venne, Gabriel; Rasquinha, Brian J; Pichora, David; Ellis, Randy E; Bicknell, Ryan
2015-07-01
Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05). Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05). We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGraw, J. Kevin; Strnad, Bradley T.; Patzik, Shayle B.
Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is an effective procedure for relieving pain due to vertebral body compression fractures. The technique employs iodinated contrast venography to exclude needle placement directly within the basivertebral complex. We present two cases in which carbon dioxide (CO{sub 2}) and gadopentetate dimeglumine venography was used to guide percutaneous vertebroplasty in patients with a contraindication to iodinated contrast.
Preparation (pulling) of needles for gene delivery by microinjection.
Dean, David A
2006-12-01
INTRODUCTIONThis protocol contains methods for pulling microinjection needles using two different models of pipette pullers. The advantage of pulling needles in the laboratory is that a variety of different needle types can be pulled, depending on the samples and cells being injected. An added advantage is cost; once a pipette puller has been purchased, boxes of glass capillaries are inexpensive compared to premade microinjection needles. The advantages to buying preformed and sterilized needles include increased uniformity of needles from one to another, ease of use, high quality, and not having to invest in a pipette puller. The pipette puller models described in this article are the Flaming/Brown Pipette Puller Model P-97 (Sutter) and the PUL-1 Micropipette Puller (World Precision Instruments). The PUL-1 instrument is the less expensive of the two, but it requires more user input, and it cannot be used to pull Femtotip-like microinjection pipettes.
Imaging behind opaque obstacle: a potential method for guided in vitro needle placement
Perinchery, Sandeep Menon; Shinde, Anant; Matham, Murukeshan Vadakke
2016-01-01
We report a simple real time optical imaging concept using an axicon lens to image the object kept behind opaque obstacles in free space. The proposed concept underlines the importance and advantages of using an axicon lens compared to a conventional lens to image behind the obstacle. The potential of this imaging concept is demonstrated by imaging the insertion of surgical needle in biological specimen in real time, without blocking the field of view. It is envisaged that this proposed concepts and methodology can make a telling impact in a wide variety of areas especially for diagnostics, therapeutics and microscopy applications. PMID:28018744
Shah, Taimur T.; Arbel, Uri; Foss, Sonja; Zachman, Andrew; Rodney, Simon; Ahmed, Hashim U.; Arya, Manit
2016-01-01
Objective To gain a better understanding of ice ball dimensions and temperature isotherms relevant for cell kill when using combinations of cryo-needles we set out to answer 4 questions: (1) what type of cryo-needle? (2) how many needles? (3) best spatial configuration? and (4) correct duty cycle percentage? Methods We conducted laboratory experiments to monitor ice ball dimensions and create multi-needle planar isotherm maps for 17G and 10G cryo-needles using a novel multi-needle thermocouple fixture within gel at body temperature. We tested configurations of 1-4 cryo-needles at duty cycles of 20%-100% with 1-2.5 cm spacing. Results Analysis of various combinations shows that a central core of ≤−40°C develops at a distance of ~1 cm around the cryo-needles. Temperature increases linearly from this point to the ice ball leading edge (0°C), which is a further ≈1 cm away. Thus, the −40°C isotherm is approximately 1 cm inside the leading edge of the ice ball. The optimum distance between cryo-needles was 1.5-2 cm, at duty cycle settings of 70%-100%. At distances further apart or with lower duty cycle settings, ice balls either had a central core >−40°C or had an hourglass shape. Conclusion In answer to questions 1-3, tumor length, diameter, and shape will ultimately determine the number of needles and their configuration. However, we propose a conservative distance for cryo-needle placement between 1 and 1.5 cm should be adopted for clinical practice. In answer to question 4, using low duty cycle settings runs the risk of incomplete −40°C isotherm coverage of the tumor, and thus in routine practice we suggest that settings of 70%-100% are most appropriate. PMID:26902833
Dynamic soft tissue deformation estimation based on energy analysis
NASA Astrophysics Data System (ADS)
Gao, Dedong; Lei, Yong; Yao, Bin
2016-10-01
The needle placement accuracy of millimeters is required in many needle-based surgeries. The tissue deformation, especially that occurring on the surface of organ tissue, affects the needle-targeting accuracy of both manual and robotic needle insertions. It is necessary to understand the mechanism of tissue deformation during needle insertion into soft tissue. In this paper, soft tissue surface deformation is investigated on the basis of continuum mechanics, where a geometry model is presented to quantitatively approximate the volume of tissue deformation. The energy-based method is presented to the dynamic process of needle insertion into soft tissue based on continuum mechanics, and the volume of the cone is exploited to quantitatively approximate the deformation on the surface of soft tissue. The external work is converted into potential, kinetic, dissipated, and strain energies during the dynamic rigid needle-tissue interactive process. The needle insertion experimental setup, consisting of a linear actuator, force sensor, needle, tissue container, and a light, is constructed while an image-based method for measuring the depth and radius of the soft tissue surface deformations is introduced to obtain the experimental data. The relationship between the changed volume of tissue deformation and the insertion parameters is created based on the law of conservation of energy, with the volume of tissue deformation having been obtained using image-based measurements. The experiments are performed on phantom specimens, and an energy-based analytical fitted model is presented to estimate the volume of tissue deformation. The experimental results show that the energy-based analytical fitted model can predict the volume of soft tissue deformation, and the root mean squared errors of the fitting model and experimental data are 0.61 and 0.25 at the velocities 2.50 mm/s and 5.00 mm/s. The estimating parameters of the soft tissue surface deformations are proven to be useful for compensating the needle-targeting error in the rigid needle insertion procedure, especially for percutaneous needle insertion into organs.
Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morton, Daniel, E-mail: dmorton@bccancer.bc.ca; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia; Hilts, Michelle
Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomicmore » regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.« less
Dhir, Vinay; Itoi, Takao; Fockens, Paul; Perez-Miranda, Manuel; Khashab, Mouen A; Seo, Dong Wan; Yang, Ai Ming; Lawrence, Khek Yu; Maydeo, Amit
2015-02-01
EUS-guided biliary drainage (EUS-BD) has emerged as an alternative rescue method in patients with failed ERCP. Opportunities for teaching and training are limited because of a low case volume at most centers. To evaluate a stereolithography/3-dimensional (3D) printing bile duct prototype for teaching and training in EUS-BD. Prospective observational feasibility study. Tertiary referral center. Twenty endosonographers attending an interventional EUS workshop. A prototype of a dilated biliary system was prepared by computer-aided design and 3D printing. The study participants performed guidewire manipulation and EUS-BD procedures (antegrade procedure and/or choledochoduodenostomy) on the prototype. Participants were scored with the device on a scale of 1 to 5 via a questionnaire. Participants' success rate for various steps of the EUS-BD procedure was noted. Subjective and objective evaluation of the prototype regarding its overall applicability, quality of radiographic and EUS images, and 4 steps of EUS-BD procedure (needle puncture, guidewire manipulation, tract dilation, stent placement). Fifteen participants returned the questionnaire, and 10 completed all 4 steps of EUS-BD. The median score for overall utility was 4, whereas that for EUS and US views was 5. Participants with experience in performing more than 20 EUS-BD procedures scored the prototype significantly lower for stent placement (P = .013) and equivalent for needle puncture, tract dilation, and wire manipulation. The success rate of various steps was 100% for needle puncture and tract dilation, 82.35% for wire manipulation, and 80% for stent placement. The mean overall procedure time was 18 minutes. Small number of participants. The 3D printing bile duct prototype appears suitable for teaching of and training in the various steps of EUS-BD. Further studies are required to elucidate its role. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron
2017-11-01
The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion. The system was mechanically calibrated and the mean image-guided needle targeting and needle trajectory accuracies were quantified in an image-guided tissue mimicking phantom experiment to be 178 ± 54 μm and 0.27 ± 0.65°, respectively. An MR image-guided system for in-bore needle deliveries to soft tissue targets in small animal models has been developed. The results of the needle targeting accuracy experiments in phantoms indicate that this system has the potential to deliver needles to the smallest soft tissue structures relevant in preclinical studies, at a wide variety of needle trajectories. Future work in the form of a fully-automated needle driver with precise depth control would benefit this system in terms of its applicability to a wider range of animal models and organ targets. © 2017 American Association of Physicists in Medicine.
Han, Nami; Yabroudi, Mohammad A.; Stearns-Reider, Kristen; Helkowski, Wendy; Sicari, Brian M.; Rubin, J. Peter; Badylak, Stephen F.; Boninger, Michael L.
2016-01-01
Background Electrodiagnosis can reveal the nerve and muscle changes following surgical placement of an extracellular matrix (ECM) bioscaffold for treatment of volumetric muscle loss (VML). Objective The purpose of this study was to characterize nerve conduction study (NCS) and electromyography (EMG) changes following ECM bioscaffold placement in individuals with VML. The ability of presurgical NCS and EMG to be used as a tool to help identify candidates who are likely to display improvements postsurgically also was explored. Design A longitudinal case series design was used. Methods The study was conducted at the McGowan Institute for Regenerative Medicine at the University of Pittsburgh. Eight individuals with a history of chronic VML participated. The intervention was surgical placement of an ECM bioscaffold at the site of VML. The strength of the affected region was measured using a handheld dynamometer, and electrophysiologic evaluation was conducted on the affected limb with standard method of NCS and EMG. All measurements were obtained the day before surgery and repeated 6 months after surgery. Results Seven of the 8 participants had a preoperative electrodiagnosis of incomplete mononeuropathy within the site of VML. After ECM treatment, 5 of the 8 participants showed improvements in NCS amplitude or needle EMG parameters. The presence of electrical activity within the scaffold remodeling site was concomitant with clinical improvement in muscle strength. Limitations This study had a small sample size, and participants served as their own controls. The electromyographers and physical therapists performing the evaluation were not blinded. Conclusions Electrodiagnostic data provide objective evidence of physiological improvements in muscle function following ECM placement at sites of VML. Future studies are warranted to further investigate the potential of needle EMG as a predictor of successful outcomes following ECM treatment for VML. PMID:26564252
Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement.
Tacher, Vania; Petit, Arthur; Derbel, Haytham; Novelli, Luigi; Vitellius, Manuel; Ridouani, Fourat; Luciani, Alain; Rahmouni, Alain; Duvoux, Christophe; Salloum, Chady; Chiaradia, Mélanie; Kobeiter, Hicham
2017-11-01
To assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement. All consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated. Sixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm 2 , fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%). This study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.
NASA Astrophysics Data System (ADS)
Kumar, Saurabh; Shrikanth, Venkoba; Amrutur, Bharadwaj; Asokan, Sundarrajan; Bobji, Musuvathi S.
2016-12-01
Several medical procedures involve the use of needles. The advent of robotic and robot assisted procedures requires dynamic estimation of the needle tip location during insertion for use in both assistive systems as well as for automatic control. Most prior studies have focused on the maneuvering of solid flexible needles using external force measurements at the base of the needle holder. However, hollow needles are used in several procedures and measurements of forces in proximity of such needles can eliminate the need for estimating frictional forces that have high variations. These measurements are also significant for endoscopic procedures in which measurement of forces at the needle holder base is difficult. Fiber Bragg grating sensors, due to their small size, inert nature, and multiplexing capability, provide a good option for this purpose. Force measurements have been undertaken during needle insertion into tissue mimicking phantoms made of polydimethylsiloxane as well as chicken tissue using an 18-G needle instrumented with FBG sensors. The results obtained show that it is possible to estimate the different stages of needle penetration including partial rupture, which is significant for procedures in which precise estimation of needle tip position inside the organ or tissue is required.
Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M
2017-12-01
The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.
A Dual Wedge Microneedle for sampling of perilymph solution via round window membrane
Watanabe, Hirobumi; Cardoso, Luis; Lalwani, Anil K.; Kysar, Jeffrey W.
2017-01-01
Objective Precision medicine for inner-ear disease is hampered by the absence of a methodology to sample inner-ear fluid atraumatically. The round window membrane (RWM) is an attractive portal for accessing cochlear fluids as it heals spontaneously. In this study, we report on the development of a microneedle for perilymph sampling that minimizes size of RWM perforation, facilitates quick aspiration, and provides precise volume control. Methods Considering the mechanical anisotropy of the RWM and hydrodynamics through a microneedle, a 31G stainless steel pipe was machined into wedge-shaped design via electrical discharge machining. Guinea pig RWM was penetrated in vitro, and 1 μ1 of perilymph was sampled and analyzed via UV-vis spectroscopy. Results The prototype wedge shaped needle created oval perforation with minor and major diameter of 143 and 344 μm (n=6). The sampling duration and standard deviation of aspirated volume were seconds and 6.8% respectively. The protein concentration was 1.74 mg/mL. Conclusion The prototype needle facilitated precise perforation of RWMs and rapid aspiration of cochlear fluid with precise volume control. The needle design is promising and requires testing in human cadaveric temporal bone and further optimization to become clinically viable. PMID:26888440
CT-guided injection of the anterior and middle scalene muscles: technique and complications.
Mashayekh, A; Christo, P J; Yousem, D M; Pillai, J J
2011-03-01
Anterior scalene block is a helpful diagnostic test for NTOS and a good predictor of surgical outcome. The purpose of this study was to describe the technique, success rate, and complications associated with CT-guided anesthetic and botulinum toxin injection of the ASM/MSM in patients with NTOS symptoms. One hundred six participants (mean age, 41.5 ± 10 years; 80 women) were identified via a retrospective review of medical records for CT-guided scalene blocks. The procedure was evaluated regarding the technical success, defined as satisfactory detection of the ASM/MSM; intramuscular needle placement; intramuscular injection of contrast; appropriate delivery of medication; and frequency of unintended BP block or other complications. We also determined the outcome of patients who underwent surgery following the block. Study participants underwent 146 scalene injections, 83 blocks, and 63 chemodenervations, which were included in this investigation. In all cases, detection of the ASM/MSM and intramuscular needle placement was satisfactory. Postprocedural complications included 5 (3.4%) temporary BP blocks, 1 patient with (0.7%) Horner sign, 7 (4.8%) needle-induced pain reports, 1 (0.7%) case of dysphagia, and 2 (1.4%) instances of muscle weakness. There were no major complications reported. The rate of good outcome following surgery was the same in patients with positive versus negative blocks, 30/43 (70%) versus 5/7 (71%), respectively. CT guidance is a useful adjunct in performing accurate ASM/MSM blocks with a low rate of minor complications.
Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior
2008-01-01
Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.
ERIC Educational Resources Information Center
Western Interstate Commission for Higher Education, 2006
2006-01-01
This document was designed to inform members of the policy, education, and research communities about existing state and institutional policies and practices associated with four accelerated learning programs: Advanced Placement (AP), dual/concurrent enrollment, the International Baccalaureate (IB) Diploma Program, and Tech-Prep. This effort was…
Wang, David; Amesur, Nikhil; Shukla, Gaurav; Bayless, Angela; Weiser, David; Scharl, Adam; Mockel, Derek; Banks, Christopher; Mandella, Bernadette; Klatzky, Roberta; Stetten, George
2010-01-01
Objective We describe a case series comprising the first clinical trial by intravenous (IV) team nurses using the Sonic Flashlight for ultrasound guidance of peripherally inserted central catheter (PICC) placement. Methods Two IV team nurses with more than 10 years experience placing PICCs and from 3–6 years experience with ultrasound (US) attempted to place PICCs under US guidance in patients requiring long-term IV access. One of two methods of US guidance was used: conventional ultrasound (CUS) (60 patients) or a new device called the Sonic Flashlight (SF) (44 patients). The number of needle punctures required to gain IV access was recorded for each subject. Results In both methods, 87% of the cases resulted in successful venous access on the first attempt. The average number of needle sticks per patient was 1.18 for SF-guided procedures, as compared to 1.20 for CUS-guided procedures. No significant difference was found in the distribution of the number of attempts between the two methods. Anecdotal comments by the nurses indicated the comparative ease of use of the SF display, although relatively small scale of the SF image compared to the CUS image was also noted. Conclusions We have shown that the Sonic Flashlight is a safe and effective device for guidance of PICC placement in the hands of experienced IV team nurses. The advantage of placing the ultrasound image at its actual location must be balanced against the relatively small scale of the SF image. PMID:19389904
Lamberton, Jordan A; Oesterle, Larry J; Shellhart, W Craig; Newman, Sheldon M; Harrell, Ricky E; Tilliss, Terri; Singh, Neha; Carey, Clifton M
2016-01-01
The use of a compound topical anesthetic (CTA) instead of an injection of a local anesthetic for placing miniscrew implants offers advantages to both the clinician and the patient. The purpose of this crossover, prospective, randomized clinical trial was to compare the clinical effectiveness of a CTA with that of a needle injection of local anesthetic for miniscrew placement. Twenty-four orthodontic patients in a university clinic were recruited; they required bilateral buccal miniscrews for orthodontic anchorage. Eligibility criteria included healthy patients with no special needs; over 8 years of age and 25 pounds; not taking sulfonamides, monoamine oxidase inhibitors, tricyclic antidepressants, or phenothiazines; and not allergic to ester-type local anesthetics or any of the other materials used in the study. A computer generated a randomization list. The allocation was randomized by anesthetic protocol and side of the mouth, and was restricted to achieve balance by treatment and side of the mouth. No allocation concealment was applied. Associated with each randomized number was the subjects' assignment into 1 of 4 groups divided by the side of first miniscrew placement and the type of anesthetic. Blinding was done only for data analysis because of clinical limitations. Each patient received a CTA on one side and an injection of anesthetic on the other before miniscrew placement in a crossover study design. The outcome was assessed by measuring pain levels with a 100-mm visual analog scale at 5 time points. Anesthetic failures occurred when the miniscrew could not be fully comfortably placed with a given anesthetic. Data were organized by visual analog scale time points, and descriptive statistics were calculated. A factorial repeated-measures analysis of variance was used to determine any differences. Twenty-seven patients were assessed for eligibility, and 24 agreed to participate in the study. Patients did not distinguish any differences in pain between the application of the CTA and the injection before or during anesthetic placement, but they experienced more pain with the CTA during miniscrew placement. The mean difference for the entire procedure between the 2 anesthesia types was 24.6 units, and the 95% confidence interval was 18.8 to 30.4, a statistically significant finding (P = 0.0002). The CTA was still viewed as more painful 1 month after the procedures. Significantly more anesthetic failures occurred with the CTA (41.6%) than with the injection (0%). No serious harm was observed in any patient; when significant pain was observed with the CTA, a needle injection of local anesthetic was administered. CTAs provided less predictable, often inadequate, and less comfortable anesthesia than an injection of a local anesthetic for managing patient discomfort during miniscrew placement in buccal sites. This trial was not registered. The protocol was determined and approved by the research committee and institutional review board before the trial. No external funding was used other than the donation of the miniscrews from Rocky Mountain Orthodontics, and no conflict of interest was declared. Copyright © 2016. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus
PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less
PERTINENT DRY NEEDLING CONSIDERATIONS FOR MINIMIZING ADVERSE EFFECTS – PART ONE
Halle, Rob J.
2016-01-01
ABSTRACT Background Dry needling is an evidence-based treatment technique that is accepted and used by physical therapists in the United States. This treatment approach focuses on releasing or inactivating muscular trigger points to decrease pain, reduce muscle tension, and assist patients with an accelerated return to active rehabilitation. Issue While commonly used, the technique has some patient risk and value of the treatment should be based on benefit compared to the potential risk. Adverse effects (AEs) with dry needling can be mild or severe, with overall incidence rates varying from zero to rates of approximately 10 percent. While mild AEs are the rule, any procedure that involves a needle insertion has the potential for an AE, with select regions and the underlying anatomy increasing the risk. Known significant AEs from small diameter needle insertion include pneumothorax, cardiac tamponade, hematoma, infection, central nervous system injury, and other complications. Purpose/Objective Underlying anatomy across individuals has variability, requiring an in-depth knowledge of anatomy prior to any needle placement. This commentary is an overview of pertinent anatomy in the region of the thorax, with a ‘part two’ that addresses the abdomen, pelvis, back, vasovagal response, informed consent and other pertinent issues. The purpose of the commentary is to minimize the risk of a dry needling AE. Conclusions/Implications Dry needling is an effective adjunct treatment procedure that is within the recognized scope of physical therapy practice. Physical therapy education and training provides practitioners with the anatomy, basic sciences, and clinical foundation to use this intervention safely and effectively. A safe and evidenced-based implementation of the procedure is based on a thorough understanding of the underlying anatomy and the potential risks, with risks coordinated with patients via informed consent. Levels of Evidence Level 5 PMID:27525188
A simple customized surgical guide for orthodontic miniplates with tube.
Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald
2012-09-01
This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.
Electron Microscopy of Dural and Arachnoid Disruptions After Subarachnoid Block.
Reina, Miguel Angel; Puigdellívol-Sánchez, Anna; Gatt, Stephen P; De Andrés, José; Prats-Galino, Alberto; van Zundert, André
It has been customary to attribute postdural puncture headache (PDPH) incidence and severity to size and nature of the dural hole produced during major neuraxial blockade or diagnostic dural puncture. Needle orientation in relation to the direction of dural fibers was thought to be of importance because of the propensity for horizontal bevel placement to cause cutting rather than splitting of the dural fibers. In vitro punctures of stringently quality-controlled human dural sac specimens were obtained with 27-gauge (27G) Whitacre needle (n = 33), with 29G Quincke used parallel to the spinal axis (n = 30), and with 29G Quincke in perpendicular approach (n = 40). The samples were studied with a scanning electron microscope, and the perimeter, appearance, and area (%) of the lesion were calculated. When using small 27G to 29G needles, neither needle tip characteristics nor needle orientation had a substantial bearing on the damage to dural fibers in the dural lesion. Of ultimate importance was the characteristic and size of the hole in the arachnoid. Arachnoid layer lesions produced by different types of spinal needles were not markedly different. Accepted theories of the etiology of PDPH need to be revised. This article marks the first time that arachnoid layer damage has been quantified. Dural fibers tend to have sufficient "memory" to close back the hole created by a spinal needle, whereas arachnoid has diminished capacity to do so. The pathogenesis of PDPH and its resolution algorithm are a far more complex process that involves many more "stages" of development than hitherto imagined.
Naganobu, Kiyokazu; Hagio, Mitsuyoshi
2007-01-01
To assess the accuracy of the 'hanging drop method' for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency. Prospective randomized-experimental study. Seventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4-26.2 kg. Dogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography. One dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs. The 'hanging drop' method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield 'false negative' results when performed in dogs positioned in sternal recumbency.
Hand gesture guided robot-assisted surgery based on a direct augmented reality interface.
Wen, Rong; Tay, Wei-Liang; Nguyen, Binh P; Chng, Chin-Boon; Chui, Chee-Kong
2014-09-01
Radiofrequency (RF) ablation is a good alternative to hepatic resection for treatment of liver tumors. However, accurate needle insertion requires precise hand-eye coordination and is also affected by the difficulty of RF needle navigation. This paper proposes a cooperative surgical robot system, guided by hand gestures and supported by an augmented reality (AR)-based surgical field, for robot-assisted percutaneous treatment. It establishes a robot-assisted natural AR guidance mechanism that incorporates the advantages of the following three aspects: AR visual guidance information, surgeon's experiences and accuracy of robotic surgery. A projector-based AR environment is directly overlaid on a patient to display preoperative and intraoperative information, while a mobile surgical robot system implements specified RF needle insertion plans. Natural hand gestures are used as an intuitive and robust method to interact with both the AR system and surgical robot. The proposed system was evaluated on a mannequin model. Experimental results demonstrated that hand gesture guidance was able to effectively guide the surgical robot, and the robot-assisted implementation was found to improve the accuracy of needle insertion. This human-robot cooperative mechanism is a promising approach for precise transcutaneous ablation therapy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Terpitz, Ulrich; Zimmermann, Dirk
2010-01-01
The Eppendorf Piezo-Power Microdissection (PPMD) system uses a tungsten needle (MicroChisel) oscillating in a forward-backward (vertical) mode to cut cells from surrounding tissue. This technology competes with laser-based dissection systems, which offer high accuracy and precision, but are more expensive and require fixed tissue. In contrast, PPMD systems can dissect freshly prepared tissue, but their accuracy and precision is lower due to unwanted lateral vibrations of the MicroChisel. Especially in tissues where elasticity is high, these vibrations can limit the cutting resolution or hamper the dissection. Here we describe a cost-efficient and simple glass capillary-encapsulation modification of MicroChisels for effective attenuation of lateral vibrations. The use of modified MicroChisels enables accurate and precise tissue dissection from highly elastic material.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H
2018-02-01
We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.
SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.
Leu, S; Ruiz, B; Podder, T
2012-06-01
To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Covington, GA) were used. The TRUS was set at 6.5MHz in water phantom at 40°C and measurements were taken with 50% and 100% TRUS gains. Needles were oriented with bevel-tip facing up (0-degree) and inserted through template grid-holes. Reference needle depths were measured when needle tip image intensity was bright enough for potentially consistent readings. High-resolution digital vernier caliper was used to measure needle depth. Needle bevel-tip orientation was then changed to bevel down (by rotating 180-degree) and needle depth was adjusted by retracting so that the needle-tip image intensity appeared similar to when the needle bevel-tip was at 0-degree orientation. Clinically relevant locations were considered for needle placement on the template grids (1st row to 9th row, and 'a-f' columns). For 50% TRUS gain, bevel tip detection errors/differences were 0.69±0.30mm (1st row) to 3.23±0.22mm (9th row) and 0.78±0.71mm (1st row) to 4.14±0.56mm (9th row) in columns 'a' and 'D', respectively. The corresponding errors for 100% TRUS gain were 0.57±0.25mm to 5.24±0.36mm and 0.84±0.30mm to 4.2±0.20mm in columns 'a' and 'D', respectively. These errors/differences varied linearly for grid-hole locations on the rows and columns in between, smaller to large depending on distance from the TRUS probe. Observed no effect of gains (50% vs. 100%) along 'D' column, which was directly above the TRUS probe. Experiment results revealed that the beveled needle tip orientation could significantly impact the detection accuracy of the needle tips, based on which the seeds might be delivered. These errors may lead to considerable dosimetric deviations in prostate brachytherapy seed implantation. © 2012 American Association of Physicists in Medicine.
Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.
Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S
2016-11-01
The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier
2017-04-01
The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Value for controlling flow of cryogenic fluid
Knapp, Philip A.
1996-01-01
A valve is provided for accurately controlling the flow of cryogenic fluids such as liquid nitrogen. The valve comprises a combination of disc and needle valves affixed to a valve stem in such a manner that the disc and needle are free to rotate about the stem, but are constrained in lateral and vertical movements. This arrangement provides accurate and precise fluid flow control and positive fluid isolation.
EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study
NASA Astrophysics Data System (ADS)
Mehrtash, Alireza; Damato, Antonio; Pernelle, Guillaume; Barber, Lauren; Farhat, Nabgha; Viswanathan, Akila; Cormack, Robert; Kapur, Tina
2014-03-01
Gynecologic malignancies, including cervical, endometrial, ovarian, vaginal and vulvar cancers, cause significant mortality in women worldwide. The standard care for many primary and recurrent gynecologic cancers consists of chemoradiation followed by brachytherapy. In high dose rate (HDR) brachytherapy, intracavitary applicators and /or interstitial needles are placed directly inside the cancerous tissue so as to provide catheters to deliver high doses of radiation. Although technology for the navigation of catheters and needles is well developed for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is notably lacking for gynecologic HDR brachytherapy. Using a benchtop study that closely mimics the clinical interstitial gynecologic brachytherapy procedure, we developed a method for evaluating the accuracy of image-guided catheter placement. Future bedside translation of this technology offers the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs, for example bladder, rectum and bowel. In the study, two independent experiments were performed on a phantom model to evaluate the targeting accuracy of an electromagnetic (EM) tracking system. The procedure was carried out using a laptop computer (2.1GHz Intel Core i7 computer, 8GB RAM, Windows 7 64-bit), an EM Aurora tracking system with a 1.3mm diameter 6 DOF sensor, and 6F (2 mm) brachytherapy catheters inserted through a Syed-Neblett applicator. The 3D Slicer and PLUS open source software were used to develop the system. The mean of the targeting error was less than 2.9mm, which is comparable to the targeting errors in commercial clinical navigation systems.
Moon, Jeong-Ho; Yamamoto, Kazuyoshi; Yanagimoto, Yoshitomo; Sugimura, Keijirou; Miyata, Hiroshi; Yano, Masahiko; Sakon, Masato
2017-01-01
Intracorporeal esophagojejunostomy after laparoscopic total gastrectomy is technically difficult because this procedure should be performed in a narrow surgical field in the upper abdomen even when completely laparoscopic approaches are used. The placement of the anvil of a circular stapling device into the esophagus and connection the instrument to the anvil are extremely difficult steps in this surgery. Therefore, we developed a simple technique for intracorporeal esophagojejunostomy using hemi-double stapling technique; we named this technique the efficient purse-string stapling technique (EST). More recently, we have developed a modified EST (mEST) that utilizes a new stainless steel anvil rod instead of a plastic rod. Relative to the plastic rod, the steel rod is reusable and shorter; thus, it was easier to perform anvil placement into the esophagus with the steel rod. Anvil preparation for mEST: a stainless steel rod is attached to the shaft of the anvil, and the needle and thread are sutured to the tip of the rod. After complete insertion of the anvil into the esophageal cavity, the needle and thread are used to penetrate the anterior esophageal wall, and the esophagus is then clamped using a linear stapler just distal to the site penetrated by the thread. The linear stapler is fired, and anvil placement in the esophagus is simultaneously accomplished. After the rod is removed from the anvil, the instrument is intracorporeally connected to the anvil and then fired to complete the gastrojejunostomy. This technique is simple and facilitates intracorporeal reconstruction procedures in laparoscopic total gastrectomy. PMID:28815221
Javan, Ramin; Zeman, Merissa N
2018-02-01
In the context of medical three-dimensional (3D) printing, in addition to 3D reconstruction from cross-sectional imaging, graphic design plays a role in developing and/or enhancing 3D-printed models. A custom prototype modular 3D model of the liver was graphically designed depicting segmental anatomy of the parenchyma containing color-coded hepatic vasculature and biliary tree. Subsequently, 3D printing was performed using transparent resin for the surface of the liver and polyamide material to develop hollow internal structures that allow for passage of catheters and wires. A number of concepts were incorporated into the model. A representative mass with surrounding feeding arterial supply was embedded to demonstrate tumor embolization. A straight narrow hollow tract connecting the mass to the surface of the liver, displaying the path of a biopsy device's needle, and the concept of needle "throw" length was designed. A connection between the middle hepatic and right portal veins was created to demonstrate transjugular intrahepatic portosystemic shunt (TIPS) placement. A hollow amorphous structure representing an abscess was created to allow the demonstration of drainage catheter placement with the formation of pigtail tip. Percutaneous biliary drain and cholecystostomy tube placement were also represented. The skills of graphic designers may be utilized in creating highly customized 3D-printed models. A model was developed for the demonstration and simulation of multiple hepatobiliary interventions, for training purposes, patient counseling and consenting, and as a prototype for future development of a functioning interventional phantom.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp; Kondo, Chiaki; Sato, Yozo
PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Twomore » tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.« less
Swartman, B; Frere, D; Wei, W; Schnetzke, M; Beisemann, N; Keil, H; Franke, J; Grützner, P A; Vetter, S Y
2017-10-01
A new software application can be used without fixed reference markers or a registration process in wire placement. The aim was to compare placement of Kirschner wires (K-wires) into the proximal femur with the software application versus the conventional method without guiding. As study hypothesis, we assumed less placement attempts, shorter procedure time and shorter fluoroscopy time using the software. The same precision inside a proximal femur bone model using the software application was premised. The software detects a K-wire within the 2D fluoroscopic image. By evaluating its direction and tip location, it superimposes a trajectory on the image, visualizing the intended direction of the K-wire. The K-wire was positioned in 20 artificial bones with the use of software by one surgeon; 20 bones served as conventional controls. A brass thumb tack was placed into the femoral head and its tip targeted with the wire. Number of placement attempts, duration of the procedure, duration of fluoroscopy time and distance to the target in a postoperative 3D scan were recorded. Compared with the conventional method, use of the application showed fewer attempts for optimal wire placement (p=0.026), shorter duration of surgery (p=0.004), shorter fluoroscopy time (p=0.024) and higher precision (p=0.018). Final wire position was achieved in the first attempt in 17 out of 20 cases with the software and in 9 out of 20 cases with the conventional method. The study hypothesis was confirmed. The new application optimised the process of K-wire placement in the proximal femur in an artificial bone model while also improving precision. Benefits lie especially in the reduction of placement attempts and reduction of fluoroscopy time under the aspect of radiation protection. The software runs on a conventional image intensifier and can therefore be easily integrated into the daily surgical routine. Copyright © 2017 Elsevier Ltd. All rights reserved.
Electromagnetic tracking for abdominal interventions in computer aided surgery
Zhang, Hui; Banovac, Filip; Lin, Ralph; Glossop, Neil; Wood, Bradford J.; Lindisch, David; Levy, Elliot; Cleary, Kevin
2014-01-01
Electromagnetic tracking has great potential for assisting physicians in precision placement of instruments during minimally invasive interventions in the abdomen, since electromagnetic tracking is not limited by the line-of-sight restrictions of optical tracking. A new generation of electromagnetic tracking has recently become available, with sensors small enough to be included in the tips of instruments. To fully exploit the potential of this technology, our research group has been developing a computer aided, image-guided system that uses electromagnetic tracking for visualization of the internal anatomy during abdominal interventions. As registration is a critical component in developing an accurate image-guided system, we present three registration techniques: 1) enhanced paired-point registration (time-stamp match registration and dynamic registration); 2) orientation-based registration; and 3) needle shape-based registration. Respiration compensation is another important issue, particularly in the abdomen, where respiratory motion can make precise targeting difficult. To address this problem, we propose reference tracking and affine transformation methods. Finally, we present our prototype navigation system, which integrates the registration, segmentation, path-planning and navigation functions to provide real-time image guidance in the clinical environment. The methods presented here have been tested with a respiratory phantom specially designed by our group and in swine animal studies under approved protocols. Based on these tests, we conclude that our system can provide quick and accurate localization of tracked instruments in abdominal interventions, and that it offers a user friendly display for the physician. PMID:16829506
An experimental animal model for percutaneous procedures used in trigeminal neuralgia.
Herta, Johannes; Wang, Wei-Te; Höftberger, Romana; Breit, Sabine; Kneissl, Sibylle; Bergmeister, Helga; Ferraz-Leite, Heber
2017-07-01
This study describes an experimental rabbit model that allows the reproduction of percutaneous operations that are used in patients with trigeminal neuralgia (TN). Attention was given to an exact anatomical description of the rabbit's middle cranial fossa as well as the establishment of conditions for a successful procedure. Morphometric measurements were taken from 20 rabbit skulls and CT scans. The anatomy of the trigeminal nerve, as well as its surrounding structures, was assessed by bilateral dissection of 13 New Zealand white rabbits (NWR). An ideal approach of placing a needle through the foramen ovale to reach the TG was sought. Validation of correct placement was realized by fluoroscopy and confirmed by dissection. Precise instructions for successful reproduction of percutaneous procedures in NWR were described. According to morphological measurements, for balloon compression of the trigeminal ganglion (TG) the maximal diameter of an introducing cannula is 1.85 mm. The diameter of an empty balloon catheter should not exceed 1.19 mm, and the length of the inflatable part of the balloon can range up to 4 mm. For thermocoagulation the needle electrodes must not exceed an external diameter of 1.39, mm and the length of the non-insolated tip can range up to 4 mm. Glycerol rhizolysis can be achieved because the trigeminal cistern in the NWR is a closed space that allows a long dwelling time (>10 min) of the contrast agent. An experimental NWR model intended for the reproduction of percutaneous procedures on the TG has been meticulously described. This provides a tool that enables further standardized animal research in the field of surgical treatment of TN.
Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.
Limmer, Alexandra M; Clement, Zackariah
2017-01-01
Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.
Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation
Clement, Zackariah
2017-01-01
Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach. PMID:28894618
Sirleo, Luigi; Innocenti, Massimo; Innocenti, Matteo; Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio
2018-02-01
To evaluate the feedback from post-operative three-dimensional computed tomography (3D-CT) on femoral tunnel placement in the learning process, to obtain an anatomic anterior cruciate ligament (ACL) reconstruction. A series of 60 consecutive patients undergoing primary ACL reconstruction using autologous hamstrings single-bundle outside-in technique were prospectively included in the study. ACL reconstructions were performed by the same trainee-surgeon during his learning phase of anatomic ACL femoral tunnel placement. A CT scan with dedicated tunnel study was performed in all patients within 48 h after surgery. The data obtained from the CT scan were processed into a three-dimensional surface model, and a true medial view of the lateral femoral condyle was used for the femoral tunnel placement analysis. Two independent examiners analysed the tunnel placements. The centre of femoral tunnel was measured using a quadrant method as described by Bernard and Hertel. The coordinates measured were compared with anatomic coordinates values described in the literature [deep-to-shallow distance (X-axis) 28.5%; high-to-low distance (Y-axis) 35.2%]. Tunnel placement was evaluated in terms of accuracy and precision. After each ACL reconstruction, results were shown to the surgeon to receive an instant feedback in order to achieve accurate correction and improve tunnel placement for the next surgery. Complications and arthroscopic time were also recorded. Results were divided into three consecutive series (1, 2, 3) of 20 patients each. A trend to placing femoral tunnel slightly shallow in deep-to-shallow distance and slightly high in high-to-low distance was observed in the first and the second series. A progressive improvement in tunnel position was recorded from the first to second series and from the second to the third series. Both accuracy (+52.4%) and precision (+55.7%) increased from the first to the third series (p < 0.001). Arthroscopic time decreased from a mean of 105 min in the first series to 57 min in the third series (p < 0.001). After 50 ACL reconstructions, a satisfactory anatomic femoral tunnel was reached. Feedback from post-operative 3D-CT is effective in the learning process to improve accuracy and precision of femoral tunnel placement in order to obtain anatomic ACL reconstruction and helps to reduce also arthroscopic time and learning curve. For clinical relevance, trainee-surgeons should use feedback from post-operative 3DCT to learn anatomic ACL femoral tunnel placement and apply it appropriately. Consecutive case series, Level IV.
Optimal angle of needle insertion for fluoroscopy-guided transforaminal epidural injection of L5.
Ra, In-Hoo; Min, Woo-Kie
2015-06-01
Unlike other sites, there is difficulty in performing TFESI at the L5-S1 level because the iliac crest is an obstacle to needle placement. The objective of this study was to identify the optimal angle of fluoroscopy for insertion and advancement of a needle during L5 TEFSI. We conducted an observational study of patients undergoing fluoroscopy-guided L5 TFESI in the prone position. A total of 80 patients (40 men and 40 women) with radiating pain of lower limbs were enrolled. During TFESI, we measured the angle at which the L5 vertebral body forms a rectangular shape and compared men and women. Then, we measured area of safe triangle in tilting angle of fluoroscopy from 15° to 35° and compared men and women. The mean cephalocaudal angle, where the vertebral body takes the shape of a rectangle, was 11.0° in men and 13.9° in women (P = 0.007). In men, the triangular area was maximal at 18.3 mm² with an oblique view angle of 25°. In women, the area was maximal at 23.6 mm² with an oblique view angle of 30°. At an oblique view angle of 30° and 35°, the area was significantly greater in women (P < 0.05). When TFESI is performed at the L5 region in the prone position, placement of fluoroscopy at a cephalocaudal angle of 11.0° and an oblique angle of 25° in men and cephalocaudal angle of 13.9° and an oblique angle of 30° in women would be most reasonable. © 2014 World Institute of Pain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, J., E-mail: juliengarnon@gmail.com; Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com; Caudrelier J, J., E-mail: caudjean@yahoo.fr
2016-05-15
ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinummore » (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.« less
Resident accuracy of joint line palpation using ultrasound verification.
Rho, Monica E; Chu, Samuel K; Yang, Aaron; Hameed, Farah; Lin, Cindy Yuchin; Hurh, Peter J
2014-10-01
To determine the accuracy of knee and acromioclavicular (AC) joint line palpation in Physical Medicine and Rehabilitation (PM&R) residents using ultrasound (US) verification. Cohort study. PM&R residency program at an academic institution. Twenty-four PM&R residents participating in a musculoskeletal US course (7 PGY-2, 8 PGY-3, and 9 PGY4 residents). Twenty-four PM&R residents participating in an US course were asked to palpate the AC joint and lateral joint line of the knee in a female and male model before the start of the course. Once the presumed joint line was localized, the residents were asked to tape an 18-gauge, 1.5-inch, blunt-tip needle parallel to the joint line on the overlying skin. The accuracy of needle placement over the joint line was verified using US. US verification of correct needle placement over the joint line. Overall AC joint palpation accuracy was 16.7%, and knee lateral joint line palpation accuracy was 58.3%. Based on the resident level of education, using a value of P < .05, there were no statistically significant differences in the accuracy of joint line palpation. Residents in this study demonstrate poor accuracy of AC joint and lateral knee joint line identification by palpation, using US as the criterion standard for verification. There were no statistically significant differences in the accuracy rates of joint line palpation based on resident level of education. US may be a useful tool to use to advance the current methods of teaching the physical examination in medical education. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Harreld, Taryn Kratz; Fowler, Sara; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike
2015-10-01
Incision and drainage of symptomatic emergency patients with facial swelling is painful even after local anesthetics are administered. The purpose of this prospective, randomized, double-blind study was to compare the pain of infiltration and the pain of an incision and drainage procedure of a buffered versus a nonbuffered 4% lidocaine formulation in symptomatic emergency patients presenting with a diagnosis of pulpal necrosis, associated periapical area, and an acute clinical swelling. Eighty-eight emergency patients were randomly divided into 2 groups to receive 2 intraoral infiltration injections (mesial and distal to the swelling) of either 4% lidocaine with 1:100,000 epinephrine buffered with 0.18 mL 8.4% sodium bicarbonate using the Onpharma (Los Gatos, CA) buffering system or 4% lidocaine with 1:100,000 epinephrine. Subjects rated the pain of needle insertion, needle placement, and solution deposition for each injection using a 170-mm visual analog scale. An incision and drainage procedure was performed, and subjects rated the pain of incision, drainage, and dissection on a 170-mm visual analog scale. No significant differences between the buffered and nonbuffered 4% lidocaine formulations were found for needle insertion, placement, and solution deposition of the infiltration injections or for the treatment phases of incision, drainage, and dissection. Buffering a 4% lidocaine formulation did not significantly decrease the pain of infiltrations or significantly decrease the pain of the incision and drainage procedure when compared with a nonbuffered 4% lidocaine formulation in symptomatic patients with a diagnosis of pulpal necrosis and associated acute swelling. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanchon, L; INSERM U1101, Brest; Apte, A
2015-06-15
Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not beenmore » previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A.« less
Thoracic costotransverse joint pain patterns: a study in normal volunteers.
Young, Brian A; Gill, Howard E; Wainner, Robert S; Flynn, Timothy W
2008-10-15
Pain referral patterns of asymptomatic costotransverse joints have not been established. The objective of this study was to determine the pain referral patterns of asymptomatic costotransverse joints via provocative intra-articular injection. Eight asymptomatic male volunteers received a combined total of 21 intra-articular costotransverse joint injections. Fluoroscopic imaging was used to identify and isolate each costotransverse joint and guide placement of a 25 gauge, 2.5 inch spinal needle into the costotransverse joint. Following contrast medium injection, the quality, intensity, and distribution of the resultant pain produced were recorded. Of the 21 costotransverse joint injections, 16 (76%) were classified as being intra-articular via arthrograms taken at the time of injection, and 14 of these injections produced a pain sensation distinctly different from that of needle placement. Average pain produced was 3.3/10 on a 0-10 verbal pain scale. Pain was described generally as a deep, dull ache, and pressure sensation. Pain patterns were located superficial to the injected joint, with only the right T2 injections showing referred pain 2 segments cranially and caudally. No chest wall, upper extremity or pseudovisceral pains were reported. This study provides preliminary data of the pain referral patterns of costotransverse joints. Further research is needed to compare these findings with those elicited from symptomatic subjects.
Gas chemical studies using corona discharge reactors
NASA Astrophysics Data System (ADS)
Schulze, P.; Stankiewicz, A.; Aicher, M.; Mattner, M.; Ulrich, A.
2010-12-01
Corona discharges with voltages up to 60 kV (DC) were studied with the aim to induce chemical reactions in flue gases at atmospheric pressure. Various plasma reactors with different geometries of multi-needle arrays were tested. The power input was optimised by studying the electrical parameters of the set-up systematically. Both, solid and liquid electrodes were used in combination with the needle arrays. A precise positioning of the corona needles allowed operation without a ballast resistor. Formation rates for CO and the sum of NO2 and O3 are reported and discussed. Three catalytic anode-coatings were tested for their potential to decompose carbon dioxide.
Robotic digital subtraction angiography systems within the hybrid operating room.
Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki
2011-05-01
Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.
Monteiro, Jardel Camilo do Carmo; Kuga, Milton Carlos; Dantas, Andrea Abi Rached; Jordão-Basso, Keren Cristina Fagundes; Keine, Katia Cristina; Ruchaya, Prashant Jay; Faria, Gisele; Leonardo, Renato de Toledo
2014-11-01
This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl; Braak, Sicco J., E-mail: sjbraak@gmail.com
2016-09-15
PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented asmore » median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.« less
Intra-opeartive OCT imaging and sensing devices for clinical translation (Conference Presentation)
NASA Astrophysics Data System (ADS)
Chen, Yu
2017-02-01
Stereotactic procedures that require insertion of needle-based instruments into the brain serve important roles in a variety of neurosurgical interventions, such as biopsy, catheterization, and electrode placement. A fundamental limitation of these stereotactic procedures is that they are blind procedures in that the operator does not have real-time feedback as to what lies immediately ahead of the advancing needle. Therefore, there is a great clinical need to navigate the instrument safely and accurately to the targets. Towards that end, we developed a forwarding-imaging needle-type optical coherence tomography (OCT) probe for avoiding the hemorrhage and guiding neurosurgical interventions. The needle probe has a thin diameter of 0.7 mm. The feasibility of vessel detection and neurosurgical guidance were demonstrated on sheep brain in vivo and human brain ex vivo. In addition, we further reduced the probe size to 0.3 mm using an optical Doppler sensing (ODS) fiber probe that can integrate with microelectrode recording (MER) to detect the blood vessels lying ahead to improve the safety of this procedure. Furthermore, to overcome the field-of-view limitation of OCT probe, we developed an MRI-compatible OCT imaging probe for neurosurgery. MRI/OCT multi-scale imaging integrates micro-resolution optical imaging with wide-field MRI imaging, and has potential to further improve the targeting accuracy.
Morrison, James; Kaufman, John
2016-12-01
Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.
Pham Dang, Charles; Lelong, Aurélie; Guilley, Jérôme; Nguyen, Jean Michel; Volteau, Christelle; Venet, Guillaume; Perrier, Cyril; Lejus, Corinne; Blanloeil, Yvonnick
2009-01-01
We clinically assessed the electrophysiologic effect of dextrose 5% in water (D5W) and of normal saline (NS) used for expansion of the perineural space before placing a stimulating catheter. We questioned if higher current was required with NS but not with D5W, as has been observed experimentally. This was a prospective randomized double-blind study of ASA I to II patients scheduled for total knee replacement. Patients from 2 hospitals were randomly assigned to receive unidentified injectate D5W (n = 25) or NS (n = 25). The primary outcome was the minimal intensity of stimulation (MIS) recorded before and after 2 and 5 mL of study injectates were flushed through the needle before placing a stimulating catheter for continuous femoral and sciatic nerve blocks. Secondary outcomes included, among other parameters, MIS recorded during placement of stimulating catheters. No difference between groups was found with MIS before injection. However, MIS recorded during neurostimulation via the needle in all blocks was significantly higher after 2 and 5 mL of NS than after D5W. In femoral blocks, MIS recorded during placement of catheters was higher during insertion after NS than after D5W but was not different after reaching the final site, regardless of injectate used. In sciatic blocks, MIS was not different during insertion regardless of injectate but was higher after NS than after D5W after reaching the final site. The current needed to electrostimulate the femoral or sciatic nerve was higher after injection of NS than after D5W.
Factors affecting blood sample haemolysis: a cross-sectional study.
Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E
2016-04-01
To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.
New platform for evaluating ultrasound-guided interventional technologies
NASA Astrophysics Data System (ADS)
Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.
2016-04-01
Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.
Retraction of the Plunger on a Syringe of Hyaluronic Acid Before Injection: Are We Safe?
Carey, Wayne; Weinkle, Susan
2015-12-01
Controversy exists concerning the need for aspiration before injection with hyaluronic acid (HA) fillers. The authors undertook a study of HA products to determine if blood could be aspirated back into a syringe of HA when the needle has been primed or filled with HA. Two studies were set up to determine if or when blood could be withdrawn from a heparinized fresh tube of blood into the HA syringe. Two different techniques were tested; one using a slow-pull retraction of the plunger and up to a 5-second waiting time before release versus a rapid pullback and quick release. Review of these data demonstrates that the usual clinical method, which involves quick withdrawal and instant release of the syringe plunger does not allow for sufficient removal of the filler found intraluminal in the needle and may give rise to false negative results in vitro and likely in vivo with the exception being the Galderma/Medicis products. In summary, withdrawal of the syringe plunger with no visible blood in the syringe does not eliminate the possibility of intravascular placement of the syringe needle.
Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.
2014-01-01
Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0–10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation. PMID:25126153
Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe
Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.
2014-01-01
Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628
NASA Astrophysics Data System (ADS)
Van De Water, P. K.
2016-12-01
The size, frequency, and morphology of leaf surface stomata is used to reconstruct past levels of atmospheric carbon dioxide over geologic time. This technique relies on measuring cell and cell-clusters to correlate with changes of known carbon dioxide levels in the atmosphere. Unfortunately, not all plants are suitable because the occurrence and placement of stomatal cell-complexes differ significantly between plant families. Monocot and dicot angiosperms exhibit different types of stomata and stomatal complexes that lack order and thus are unsuitable. But, in gymnosperms, the number and distribution of stomata and pavement cells is formalized and can be used to reconstruct past atmospheric carbon dioxide levels. However, characteristic of each plant species must still be considered. For example, conifers are useful but are divided into two-needle to five-needle pines, or have irregular surface morphology (Pseudotsuga sp. and Tsuga sp. needles). This study uses Pinus monophylla an undivided needle morphology, that being a cylinder has no interior surface cells. Pinus monophylla (single needle pinyon) needles were collected along Geiger Grade (Nevada State Highway 341, Reno) in 2005 and 2013 from 1500m to 2195m. Herbarium samples were also collected from 13 historic collections made between 1911 and 1994. The study determined changes with elevation and/or over time using in these populations. Using Pinus monophylla, insured needles represented a single surface with stomata, stomatal complex cells, and co-occurring pavement cell types. Results show decreased stomatal densities (stomata/area), stomatal index (stomata/stomata + epidermal cells) and stable stomata per row (stomata/row) . Epidermal cell density (Epidermal Cells /Area), and Pavement cell density (Pavement cell/area) track stomatal density similarly. Data comparison, using elevation in the 2005 and 2013 collections showed no-significant trends. Individual stomatal complexes show no differences in the size and shape over time or with elevation. Stomata morphology and the stomatal pores appear conservative. However some complex cells show a morphology suggesting they are not fully formed and functional. These characteristics appear often in the modern material suggesting some stomata never fully develop.
Gauly, Adelheid; Parisotto, Maria Teresa; Skinder, Aleksandra; Schoder, Volker; Furlan, Andreja; Schuh, Erika; Marcelli, Daniele
2011-01-01
The appropriate use of vascular access is of fundamental importance in the treatment of hemodialysis (HD) patients. This survey entailed collecting data on current practice of vascular access cannulation to assess its relation to dialysis dose. This international, multicenter, observational, cross-sectional survey was performed in 171 dialysis centers of the European dialysis network of Fresenius Medical Care in Europe and South Africa during April 2009. Practice patterns of vascular access cannulations were documented by means of a 24-item questionnaire. Dialysis dose from the documented hemodialysis treatments was derived from the clinical database EuCliD®. In total, 10,807 cannulations in hemodialysis patients with either arteriovenous fistula (91%) or arteriovenous graft (9%) were documented. For the puncture, the area technique was applied most frequently using 15G and 16G needles. Blood flow rates were mostly between 300 and 400 mL/min and adjusted to the needle size used. In two-thirds of cases the arterial needle was placed first, mostly in an antegrade direction, with an average distance to the venous needle of 7.0±3.7 cm. More than two-thirds of the cannulations were performed by nurses with more than 5 years of experience in dialysis. A logistic regression model revealed a significantly higher odds ratio to attain Kt/V = 1.2 for retrograde placement of the arterial needle, and for using needles with bigger diameter. This survey covered a broad number of countries and centers and provides information on current practice of vascular access cannulation, their effect on dialysis dose, and serves as feedback to the dialysis centers for their quality management process.
NASA Astrophysics Data System (ADS)
Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko
2018-04-01
Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p < 0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Safriel, Yair; Ang, Roberto; Ali, Muhammed
2008-03-15
Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualizedmore » using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered.« less
Convolution neural networks for real-time needle detection and localization in 2D ultrasound.
Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker
2018-05-01
We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.
Ristev, Goran; Sipes, Angela C; Mahoney, Bryan; Lipps, Jonathan; Chan, Gary; Coffman, John C
2017-01-01
The rationale for injection of epidural medications through the needle is to promote sooner onset of pain relief relative to dosing through the epidural catheter given that needle injection can be performed immediately after successful location of the epidural space. Some evidence indicates that dosing medications through the epidural needle results in faster onset and improved quality of epidural anesthesia compared to dosing through the catheter, though these dosing techniques have not been compared in laboring women. This investigation was performed to determine whether dosing medication through the epidural needle improves the quality of analgesia, level of sensory blockade, or onset of pain relief measured from the time of epidural medication injection. In this double-blinded prospective investigation, healthy term laboring women (n=60) received labor epidural placement upon request. Epidural analgesia was initiated according to the assigned randomization group: 10 mL loading dose (0.125% bupivacaine with fentanyl 2 µg/mL) through either the epidural needle or the catheter, given in 5 mL increments spaced 2 minutes apart. Verbal rating scale (VRS) pain scores (0-10) and pinprick sensory levels were documented to determine the rates of analgesic and sensory blockade onset. No significant differences were observed in onset of analgesia or sensory blockade from the time of injection between study groups. The estimated difference in the rate of pain relief (VRS/minute) was 0.04 (95% CI: -0.01 to 0.11; p =0.109), and the estimated difference in onset of sensory blockade (sensory level/minute) was 0.63 (95% CI: -0.02 to 0.15; p =0.166). The time to VRS ≤3 and level of sensory block 20 minutes after dosing were also similar between groups. No differences in patient satisfaction, or maternal or fetal complications were observed. This investigation observed that epidural needle and catheter injection of medications result in similar onset of analgesia and sensory blockade, quality of labor analgesia, patient satisfaction, and complication rates.
Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit
2017-01-01
Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
The Hydrodynamics of Needle-Free Intradermal Jet Injection
NASA Astrophysics Data System (ADS)
Simmons, Jonathan; Marston, Jeremy; Fisher, Paul; Broderick, Kate
2017-11-01
Needle-free methods of drug delivery circumvent the drawbacks associated with the use of hypodermic needles such as needle-stick injuries, needle-phobia, cross contamination and disposal. Furthermore, pioneering DNA-based vaccines that aim to treat cancer and fight infectious diseases, such as HIV, Ebola and Zika, require precise deposition into the skin to target the immune response producing cells found only in the epidermis and dermis. Intradermal (ID) delivery can be achieved using a needle and the Mantoux technique but this requires a highly skilled technician and so extensive use of DNA vaccines calls for an alternative method of delivery. One option is jet injection which has been employed in mass vaccination programs for intramuscular or subcutaneous delivery and is used by some diabetic patients to inject insulin. In this talk I will present results from our ongoing ex-vivo experimental study into ID jet injection. Ultra-high-speed imaging is used to visualize the process of the jet exiting the nozzle and striking excised skin. A skin bleb grows as liquid is deposited within the skin. I will discuss how the control parameters, such as the rheological profile of the liquid and the stand-off distance, influence the volume of liquid successfully delivered intradermally.
Needle puncture in rabbit functional spinal units alters rotational biomechanics.
Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D
2015-04-01
An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.
Psycho-Motor and Error Enabled Simulations: Modeling Vulnerable Skills in the Pre-Mastery Phase
2016-04-01
participants. Multiple abstracts and posters were created for surgical conferences attended. These works concentrated on data from pre and post ...analyzed to give every participant a perspective of the smallest difference in stiffness they could differentiate. Based on the results the tests were...camera was affixed to a post mounted to this station’s table to capture a close-up view of the participant’s placement of needles on the simulation
2015-01-01
Objective Irreversible electroporation (IRE) of stage 3 pancreatic adenocarcinoma has been used to provide quality of life time in patients who have undergone appropriate induction therapy. The optimal technique has been reported within the literature, but not in video form. IRE of locally advanced pancreatic cancer is technically demanding requiring precision ultrasound use for continuous imaging in multiple needle placements and during IRE energy delivery. Methods Appropriate patients with locally advanced pancreatic cancer should have undergone appropriate induction chemotherapy for a reasonable duration. The safe and effective technique for irreversible electroporation is preformed through an open approach with the emphasis on intra-operative ultrasound and intra-operative electroporation management. Results The technique of open irreversible electroporation of the pancreas involves bracketing the target tumor with IRE probes and any and all invaded vital structures including the celiac axis, superior mesenteric artery (SMA), superior mesenteric-portal vein, and bile duct with continuous intraoperative ultrasound imaging through a caudal to cranial approach. Optimal IRE delivery requires a change in amperage of at least 12 amps from baseline tissue conductivity in order to achieve technical success. Multiple pull-backs are necessary since the IRE ablation probe lengths are 1 cm and thus needed to achieve technical success along the caudal to cranial plane. Conclusions Irreversible electroporation in combination with multi-modality therapy for locally advanced pancreatic carcinoma is feasible for appropriate patients with locally advanced cancer. Technical demands are high and require the highest quality ultrasound for precise spacing measurements and optimal delivery to ensure adequate change in tissue resistance. PMID:29075594
Rapid and precise determination of ATP using a modified photometer
Shultz, David J.; Stephens, Doyle W.
1980-01-01
An inexpensive delay timer was designed to modify a commercially available ATP photometer which allows a disposable tip pipette to be used for injecting either enzyme or sample into the reaction cuvette. The disposable tip pipette is as precise and accurate as a fixed-needle syringe but eliminates the problem of sample contamination and decreases analytical time. (USGS)
Singh, Sukhdip; Wirth, Keith M.; Phelps, Amy L.; Badve, Manasi H.; Shah, Tanmay H.; Vallejo, Manuel C.
2013-01-01
Background. Previously, Balki determined the Pearson correlation coefficient with the use of ultrasound (US) was 0.85 in morbidly obese parturients. We aimed to determine if the use of the epidural depth equation (EDE) in conjunction with US can provide better clinical correlation in estimating the distance from the skin to the epidural space in morbidly obese parturients. Methods. One hundred sixty morbidly obese (≥40 kg/m2) parturients requesting labor epidural analgesia were enrolled. Before epidural catheter placement, EDE was used to estimate depth to the epidural space. This estimation was used to help visualize the epidural space with the transverse and midline longitudinal US views and to measure depth to epidural space. The measured epidural depth was made available to the resident trainee before needle insertion. Actual needle depth (ND) to the epidural space was recorded. Results. Pearson's correlation coefficients comparing actual (ND) versus US estimated depth to the epidural space in the longitudinal median and transverse planes were 0.905 (95% CI: 0.873 to 0.929) and 0.899 (95% CI: 0.865 to 0.925), respectively. Conclusion. Use of the epidural depth equation (EDE) in conjunction with the longitudinal and transverse US views results in better clinical correlation than with the use of US alone. PMID:23983645
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen
Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle wasmore » again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible.« less
Amouyal, G; Pernot, S; Déan, C; Cholley, B; Scotté, F; Sapoval, M; Pellerin, O
2017-11-01
The aim of this study was to assess the feasibility, safety and efficacy of percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma using C-arm cone beam computed tomography (CBCT) guidance. This single-center prospective observational study was performed from August 2013 to August 2016, and included consecutive patients referred for radiofrequency ablation of lung metastases from colorectal cancer. Radiofrequency ablation procedures were performed under C-arm CBCT guidance. Feasibility was assessed by probe accuracy placement, time to accurate placement and number of C-arm CBCT acquisitions to reach the target lesion. Safety was assessed by the report of adverse event graded using the common terminology criteria for adverse events (CTCAE-V4.0). Efficacy was assessed by metastases response rate using RECIST 1.1 and 18 FDG-PET-CT tumor uptake at 6months. Fifty-four consecutive patients (32 men, 22 women) with a mean age of 63±8 (SD) years (range: 51-81years) with a total of 56 lung metastasis from colorectal metastases were treated in a single session. The mean tumor diameter was 25.6±4.5 (SD)mm (range: 17-31mm). Median time to insert the needle into the target lesion was 10min (range: 5-25min). Median number of needles repositioning and C-arm CBCT acquisition per patient was 1 (range: 0-3) and 4 (range: 3-6) respectively. The accuracy for radiofrequency ablation probe placement was 2±0.2 (SD)mm (range: 0-9mm). Pneumothorax requiring chest tube placement occurred in one patient (CTCAE-V4.0 grade 3). At 6months, all patients were alive with tumor response rate of -27% and had no significant activity on the 18 FDG-PET CT follow-up. Percutaneous radiofrequency ablation of lung metastases from colorectal cancer under C-arm CBCT guidance is feasible and safe, with immediate and short-term results similar to those obtained using conventional CT guidance. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Comparison of concentric needle versus hooked-wire electrodes in the canine larynx.
Jaffe, D M; Solomon, N P; Robinson, R A; Hoffman, H T; Luschei, E S
1998-05-01
The use of a specific electrode type in laryngeal electromyography has not been standardized. Laryngeal electromyography is usually performed with hooked-wire electrodes or concentric needle electrodes. Hooked-wire electrodes have the advantage of allowing laryngeal movement with ease and comfort, whereas the concentric needle electrodes have benefits from a technical aspect and may be advanced, withdrawn, or redirected during attempts to appropriately place the electrode. This study examines whether hooked-wire electrodes permit more stable recordings than standard concentric needle electrodes at rest and after large-scale movements of the larynx and surrounding structures. A histologic comparison of tissue injury resulting from placement and removal of the two electrode types is also made by evaluation of the vocal folds. Electrodes were percutaneously placed into the thyroarytenoid muscles of 10 adult canines. Amplitude of electromyographic activity was measured and compared during vagal stimulation before and after large-scale laryngeal movements. Signal consistency over time was examined. Animals were killed and vocal fold injury was graded and compared histologically. Waveform morphology did not consistently differ between electrode types. The variability of electromyographic amplitude was greater for the hooked-wire electrode (p < 0.05), whereas the mean amplitude measures before and after large-scale laryngeal movements did not differ (p > 0.05). Inflammatory responses and hematoma formation were also similar. Waveform morphology of electromyographic signals registered from both electrode types show similar complex action potentials. There is no difference between the hooked-wire electrode and the concentric needle electrode in terms of electrode stability or vocal fold injury in the thyroarytenoid muscle after large-scale laryngeal movements.
Klauser, Andrea; De Zordo, Tobias; Feuchtner, Gudrun; Sögner, Peter; Schirmer, Michael; Gruber, Johann; Sepp, Norbert; Moriggl, Bernhard
2008-11-15
Sacroiliitis is often caused by rheumatic diseases, and besides other therapeutic options, treatment consists of intraarticular injection of corticosteroids. The purpose of this study was to assess the feasibility of ultrasound (US)-guided sacroiliac joint (SI joint) injection at 2 different puncture levels in cadavers and patients when defined sonoanatomic landmarks were considered. After defining sonoanatomic landmarks, US-guided needle insertion was performed in 10 human cadavers (20 SI joints) at 2 different puncture sites. Upper level was defined at the level of the posterior sacral foramen 1 and lower level at the level of the posterior sacral foramen 2. In 10 patients with unilateral sacroiliitis, injection at the most feasible level was attempted. Computed tomography confirmed correct intraarticular needle placement in cadavers by showing the tip of the needle in the joint and intraarticular diffusion of contrast media in 16 (80%) of 20 SI joints (upper level 7 [70%] of 10; lower level 9 [90%] of 10). In all 4 cases in which needle insertion failed, intraarticular SI joint injection at the other level was successful. In patients, 100% of US-guided injections were successful (8 lower level, 2 upper level), with a mean pain relief of 8.6 after 3 months. US guidance of needle insertion into SI joints was feasible at both levels when defined sonoanatomic landmarks were used. If SI joint alterations do not allow for direct visualization of the dorsal joint space of the lower level, which is easier to access, the upper level might offer an appropriate alternative.
Dobberfuhl, Amy D; Spettel, Sara; Schuler, Catherine; Levin, Robert M; Dubin, Andrew H; De, Elise J B
2015-12-01
Existing data supports a relationship between pelvic floor dysfunction and lower urinary tract symptoms. We developed a survival model of pelvic floor dysfunction in the rabbit and evaluated cystometric (CMG), electromyographic (EMG) and ambulatory voiding behavior. Twelve female adult virgin rabbits were housed in metabolic cages to record voiding and defecation. Anesthetized CMG/EMG was performed before and after treatment animals (n=9) received bilateral tetanizing needle stimulation to the pubococcygeous (PC) muscle and controls (n=3) sham needle placement. After 7 days all animals were subjected to tetanizing transvaginal stimulation and CMG/EMG. After 5 days a final CMG/EMG was performed. Of rabbits that underwent needle stimulation 7 of 9 (78%) demonstrated dysfunctional CMG micturition contractions versus 6 of 12 (50%) after transvaginal stimulation. Needle stimulation of the PC musculature resulted in significant changes in: basal CMG pressure, precontraction pressure change, contraction pressure, interval between contractions and postvoid residual; with time to 3rd contraction increased from 38 to 53 minutes (p=0.008 vs. prestimulation). Vaginal noxious stimulation resulted in significant changes in: basal CMG pressure and interval between contractions; with time to 3rd contraction increased from 37 to 46 minutes (p=0.008 vs. prestimulation). Changes in cage parameters were primarily seen after direct needle stimulation. In a majority of animals, tetanizing electrical stimulation of the rabbit pelvic floor resulted in voiding changes suggestive of pelvic floor dysfunction as characterized by a larger bladder capacity, longer interval between contractions and prolonged contraction duration.
Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy
Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter
2016-01-01
We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122
Can a virtual reality assessment of fine motor skill predict successful central line insertion?
Mohamadipanah, Hossein; Parthiban, Chembian; Nathwani, Jay; Rutherford, Drew; DiMarco, Shannon; Pugh, Carla
2016-10-01
Due to the increased use of peripherally inserted central catheter lines, central lines are not performed as frequently. The aim of this study is to evaluate whether a virtual reality (VR)-based assessment of fine motor skills can be used as a valid and objective assessment of central line skills. Surgical residents (N = 43) from 7 general surgery programs performed a subclavian central line in a simulated setting. Then, they participated in a force discrimination task in a VR environment. Hand movements from the subclavian central line simulation were tracked by electromagnetic sensors. Gross movements as monitored by the electromagnetic sensors were compared with the fine motor metrics calculated from the force discrimination tasks in the VR environment. Long periods of inactivity (idle time) during needle insertion and lack of smooth movements, as detected by the electromagnetic sensors, showed a significant correlation with poor force discrimination in the VR environment. Also, long periods of needle insertion time correlated to the poor performance in force discrimination in the VR environment. This study shows that force discrimination in a defined VR environment correlates to needle insertion time, idle time, and hand smoothness when performing subclavian central line placement. Fine motor force discrimination may serve as a valid and objective assessment of the skills required for successful needle insertion when placing central lines. Copyright © 2016 Elsevier Inc. All rights reserved.
Effects of ankle-foot orthoses on mediolateral foot-placement ability during post-stroke gait.
Zissimopoulos, Angelika; Fatone, Stefania; Gard, Steven
2015-10-01
Accurate and precise mediolateral foot placement is important for balance during gait, but is impaired post stroke. Mediolateral foot placement may be improved with ankle-foot orthosis use. The purpose of this study was to determine whether an ankle-foot orthosis improves mediolateral foot-placement ability during post-stroke ambulation. Crossover trial with randomized order of conditions tested. The accuracy and precision of mediolateral foot placement was quantified while subjects targeted four different randomized step widths. Subjects were tested with and without their regular non-rigid ankle-foot orthosis in two separate visits (order randomized). While ankle-foot orthosis use corrected foot and ankle alignment (i.e. significantly decreased mid-swing plantar flexion, p = 0.000), effects of ankle-foot orthosis use on hip hiking (p = 0.545), circumduction (p = 0.179), coronal plane hip range of motion (p = 0.06), and mediolateral foot-placement ability (p = 0.537) were not significant. While ankle-foot orthosis-mediated equinovarus correction of the affected foot and ankle was not associated with improved biomechanics of walking (i.e. proximal ipsilateral hip kinematics or mediolateral foot-placement ability), it may affect other aspects of balance that were not tested in this study (e.g. proprioception, cerebellar, vestibular, and cognitive mechanisms). Studies that investigate the effect of ankle-foot orthosis on gait can help advance stroke rehabilitation by documenting the specific gait benefits of ankle-foot orthosis use. In this study, we investigated the effect of ankle-foot orthosis use on mediolateral foot-placement ability, an aspect of gait important for maintaining balance. © The International Society for Prosthetics and Orthotics 2014.
Why are mini-implants lost: the value of the implantation technique!
Romano, Fabio Lourenço; Consolaro, Alberto
2015-01-01
The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.
De Nicola, F; Concha Graña, E; Aboal, J R; Carballeira, A; Fernández, J Á; López Mahía, P; Prada Rodríguez, D; Muniategui Lorenzo, S
2016-06-01
Due to the complexity and heterogeneity of plant matrices, new procedure should be standardized for each single biomonitor. Thus, here is described a matrix solid-phase dispersion extraction method, previously used for moss samples, improved and modified for the analyses of PAHs in Quercus robur leaves and Pinus pinaster needles, species widely used in biomonitoring studies across Europe. The improvements compared to the previous procedure are the use of Florisil added with further clean-up sorbents, 10% deactivated silica for pine needles and PSA for oak leaves, being these matrices rich in interfering compounds, as shown by the gas chromatography-mass spectrometry analyses acquired in full scan mode. Good trueness, with values in the range 90-120% for the most of compounds, high precision (intermediate precision between 2% and 12%) and good sensitivity using only 250mg of samples (limits of quantification lower than 3 and 1.5ngg(-1), respectively for pine and oak) were achieved by the selected procedures. These methods proved to be reliable for PAH analyses and, having advantage of fastness, can be used in biomonitoring studies of PAH air contamination. Copyright © 2016 Elsevier B.V. All rights reserved.
Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.
Soong, W J; Jeng, M J; Hwang, B
1996-01-01
A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu
Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less
NASA Astrophysics Data System (ADS)
McIntire, John P.; Wright, Steve T.; Harrington, Lawrence K.; Havig, Paul R.; Watamaniuk, Scott N. J.; Heft, Eric L.
2014-06-01
Twelve participants were tested on a simple virtual object precision placement task while viewing a stereoscopic three-dimensional (S3-D) display. Inclusion criteria included uncorrected or best corrected vision of 20/20 or better in each eye and stereopsis of at least 40 arc sec using the Titmus stereotest. Additionally, binocular function was assessed, including measurements of distant and near phoria (horizontal and vertical) and distant and near horizontal fusion ranges using standard optometric clinical techniques. Before each of six 30 min experimental sessions, measurements of phoria and fusion ranges were repeated using a Keystone View Telebinocular and an S3-D display, respectively. All participants completed experimental sessions in which the task required the precision placement of a virtual object in depth at the same location as a target object. Subjective discomfort was assessed using the simulator sickness questionnaire. Individual placement accuracy in S3-D trials was significantly correlated with several of the binocular screening outcomes: viewers with larger convergent fusion ranges (measured at near distance), larger total fusion ranges (convergent plus divergent ranges, measured at near distance), and/or lower (better) stereoscopic acuity thresholds were more accurate on the placement task. No screening measures were predictive of subjective discomfort, perhaps due to the low levels of discomfort induced.
Graffy, Peter; Loomis, Scott B; Pickhardt, Perry J; Lubner, Meghan G; Kitchin, Douglas R; Lee, Fred T; Hinshaw, J Louis
2017-04-01
To investigate whether an autologous intraparenchymal blood patch (IPB) reduces the rate of pneumothorax-related complications associated with computed tomography (CT)-guided lung biopsies. This study included 834 patients: 482 who received an IPB and 352 who did not. Retrospective review was performed of all CT-guided lung biopsies performed at a single institution between August 2006 and September 2013. Patients were excluded if no aerated lung was crossed. The rate of pneumothorax, any associated intervention (eg, catheter placement, aspiration), chest tube placement, and chest tube replacement requiring hospital admission were compared by linear and multiple regression analysis. Patients who received an IPB had a significantly lower rate of pneumothorax (145 of 482 [30%] vs 154 of 352 [44%]; P < .0001), pneumothorax-related intervention (eg, catheter aspiration, pleural blood patch, chest tube placement; 43 of 482 [8.9%] vs 85 of 352 [24.1%]; P < .0001), and chest tube placement along with other determinants requiring hospital admission (18 of 482 [3.7%] vs 27 of 352 [7.7%]; P < .0001). No complications related to the IPB were noted in the study group. Autologous IPB placement is associated with a decreased rate of pneumothorax and associated interventions, including chest tube placement and hospital admission, after CT-guided lung biopsies, with no evidence of any adverse effects. These results suggest that an IPB is safe and effective and should be considered when aerated lung is traversed while performing a CT-guided lung biopsy. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Resuscitation in massive obstetric haemorrhage using an intraosseous needle.
Chatterjee, D J; Bukunola, B; Samuels, T L; Induruwage, L; Uncles, D R
2011-04-01
A 38-year-old woman experienced a massive postpartum haemorrhage 30 minutes after emergency caesarean delivery. The patient became severely haemodynamically compromised with an unrecordable blood pressure. Rapid fluid resuscitation was limited by the capacity of the intravenous cannula in place at the time and inability to establish additional vascular access using conventional routes in a timely manner. An intraosseous needle was inserted in the proximal humerus at the first attempt and administration of resuscitation fluid by this route subsequently enabled successful placement of further intravenous lines. Blood and blood products were deployed in conjunction with intra-operative cell salvage and transoesophageal Doppler cardiac output monitoring was used to assess adequacy of volume replacement. Haemorrhage control was finally achieved with the use of recombinant factor VIIa and hysterectomy. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.
Wiewiorski, Martin; Takes, Martin Thanh Long; Valderrabano, Victor; Jacob, Augustinus Ludwig
2012-03-01
Image guidance is valuable for diagnostic injections in foot orthopaedics. Flat-detector computed tomography (FD-CT) was implemented using a C-arm, and the system was tested for needle guidance in foot joint injections. FD-CT-guided joint infiltration was performed in 6 patients referred from the orthopaedic department for diagnostic foot injections. All interventions were performed utilising a flat-panel fluoroscopy system utilising specialised image guidance and planning software. Successful infiltration was defined by localisation of contrast media depot in the targeted joint. The pre- and post-interventional numeric analogue scale (NAS) pain score was assessed. All injections were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of symptoms was noted by all 6 participants. FD-CT-guided joint infiltration is a feasible method for diagnostic infiltration of midfoot and hindfoot joints. The FD-CT approach may become an alternative to commonly used 2D-fluoroscopically guidance.
Assistive technology for ultrasound-guided central venous catheter placement.
Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana
2018-01-01
This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.
Severe pruritus and myoclonus following intrathecal morphine administration in a dog
Iff, Isabelle; Valeskini, Karin; Mosing, Martina
2012-01-01
During epidural needle placement in a 32-kg dog the subarachnoid space was punctured and half the intended dose of lidocaine, bupivacaine, and morphine was injected. After recovery from anesthesia the dog showed signs of severe pruritus of the tail base and limbs and myoclonus of the tail and hind limbs. Methadone, acepromazine, ketamine, buprenorphine, and butorphanol were administered to control myoclonus and pruritus, but were unsuccessful. Diazepam was used to control myoclonus until the effects of morphine abated. PMID:23450863
Suh, Robert D; Goldin, Jonathan G; Wallace, Amanda B; Sheehan, Ramon E; Heinze, Stefan B; Gitlitz, Barbara J; Figlin, Robert A
2004-05-01
To assess the technical feasibility and safety of weekly outpatient percutaneous computed tomographic (CT)-guided intratumoral injections of interleukin-2 (IL-2) plasmid DNA in a wide variety of superficial and deep tumor sites. Twenty-nine patients with metastatic renal cell carcinoma and a total of 30 lesions measuring 1.0 cm(2) or greater in accessible thoracic (n = 15) or abdominal (n = 15) locations underwent up to three cycles of six weekly intratumoral IL-2 plasmid DNA injections. CT was used to guide needle placement and injection. After injection cycle 1, patients whose tumors demonstrated stable (< or =25% increase and < or =50% decrease in product of lesion diameters) or decreased size (>50% decrease in product of lesion diameters) advanced to injection cycle 2. Patients whose lesions decreased in size by more than 50% over the course of injection cycle 2 were eligible to begin injection cycle 3. An acceptable safety and technical feasibility profile for this technique was deemed to be (a) a safety and feasibility profile similar to that of single-needle biopsy and (b) an absence of serious adverse events (as defined in Title 21 of the Code of Federal Regulations) and/or unacceptable toxicities (as graded according to the National Cancer Institute Common Toxicity Criteria). A total of 284 intratumoral injections were performed, with a mean of 9.8 injections (range, 6-18 injections) received by each patient. Technical success (needle placement and injection of gene therapy agent) was achieved in all cases. Complications were experienced after 42 (14.8%) of the 284 injections. The most common complication was pneumothorax (at 32 [28.6%] of 112 intrathoracic injections), for which only one patient required catheter drainage. Complications occurred randomly throughout injection cycles and did not appear to increase as patients received more injections (P =.532). No patient experienced serious adverse events or unacceptable toxicities. Percutaneous CT-guided intratumoral immunotherapy injections are technically feasible and can be safely performed.
Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B
2017-12-01
To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (p<0.001), longer transparenchymal distance (p<0.001), and prone position (p=0.027). There was positive correlation between the need for chest tube placement and longer transparenchymal distance (p=0.007) and smaller lesion diameter (p=0.018). Lesions in the left lower lobe had the lowest rates of pneumothorax (p=0.008) and chest tube drainage (p=0.018). Patients whose pneumothoraces were diagnosed on the follow-up chest X-ray, but not on the immediate post-procedural CT scan had significantly higher requirement for chest tube drainage (p=0.039). CT-guided lung biopsy has a high rate of technical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron
2014-03-01
Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.
Xie, Yu; Liu, Shuang; Sun, Dong
2018-01-01
Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future. PMID:29439539
Yang, Chongjun; Xie, Yu; Liu, Shuang; Sun, Dong
2018-02-12
Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.
Effect of ambient light and age-related macular degeneration on precision walking.
Alexander, M Scott; Lajoie, Kim; Neima, David R; Strath, Robert A; Robinovitch, Stephen N; Marigold, Daniel S
2014-08-01
To determine how age-related macular degeneration (AMD) and changes in ambient light affect the control of foot placement while walking. Ten older adults with AMD and 11 normal-sighted controls performed a precision walking task under normal (∼600 lx), dim (∼0.7 lx), and after a sudden reduction (∼600 to 0.7 lx) of light. The precision walking task involved subjects walking and stepping to the center of a series of irregularly spaced, low-contrast targets. Habitual visual acuity and contrast sensitivity and visual field function were also assessed. There were no differences between groups when performing the walking task in normal light (p > 0.05). In reduced lighting, older adults with AMD were less accurate and more variable when stepping across the targets compared to controls (p < 0.05). A sudden reduction of light proved the most challenging for this population. In the AMD group, contrast sensitivity and visual acuity were not significantly correlated with walking performance. Visual field thresholds in the AMD group were only associated with greater foot placement error and variability in the dim light walking condition (r = -0.69 to -0.87, p < 0.05). While walking performance is similar between groups in normal light, poor ambient lighting results in decreased foot placement accuracy in older adults with AMD. Improper foot placement while walking can lead to a fall and possible injury. Thus, to improve the mobility of those with AMD, strategies to enhance the environment in reduced lighting situations are necessary.
Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A
2005-01-01
To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.
NASA Astrophysics Data System (ADS)
Lin, Yi; Jiang, Miao
2017-01-01
Tree species information is essential for forest research and management purposes, which in turn require approaches for accurate and precise classification of tree species. One such remote sensing technology, terrestrial laser scanning (TLS), has proved to be capable of characterizing detailed tree structures, such as tree stem geometry. Can TLS further differentiate between broad- and needle-leaves? If the answer is positive, TLS data can be used for classification of taxonomic tree groups by directly examining their differences in leaf morphology. An analysis was proposed to assess TLS-represented broad- and needle-leaf structures, followed by a Bayes classifier to perform the classification. Tests indicated that the proposed method can basically implement the task, with an overall accuracy of 77.78%. This study indicates a way of implementing the classification of the two major broad- and needle-leaf taxonomies measured by TLS in accordance to their literal definitions, and manifests the potential of extending TLS applications in forestry.
Sarnthein, Johannes; Lüchinger, Roger; Piccirelli, Marco; Regli, Luca; Bozinov, Oliver
2016-09-01
High-field intraoperative magnetic resonance imaging (ioMRI) is becoming increasingly available in neurosurgery centers, where it has to be combined with intraoperative neurophysiologic monitoring (IONM). IONM needle electrodes remain on the patient during ioMRI and may cause image distortions and burns. We tested magnetic resonance (MR) -heating experimentally and investigated the prevalence of complications. We studied electrodes that are certified for IONM, but not "MR conditional." They consist of copper cables (length, 1.5 m) and needles made of either stainless steel (ferromagnetic) or paramagnetic platinum/iridium alloy. We simulated an ioMRI session with gel and measured the temperature increase with optical fibers. We measured the force that an electrode experiences in the magnetic field. Between 2013 and 2016, we prospectively documented subcutaneous needle electrodes that remained in the patient during intraoperative 3 Tesla ioMRI scans. The in vitro testing of the electrodes produced a maximum heating (ΔT = 3.9°C) and force of 0.026 N. We placed 1237 subcutaneous needles in 57 surgical procedures with combined IONM and ioMRI, where needles remained in place during ioMRI. One patient suffered a skin burn on the shoulder. All other electrodes had no side effects. We have corroborated the history of safe use for electrodes with 1.5 m cable in a 3T MRI scanner and demonstrated their use. Nevertheless, heating cannot be excluded, as it depends on location and cable placement. When leaving electrodes in place during ioMRI, risks and benefits have to be carefully evaluated for each patient. Copyright © 2016 Elsevier Inc. All rights reserved.
Design and optimization of a brachytherapy robot
NASA Astrophysics Data System (ADS)
Meltsner, Michael A.
Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frederick, Amy; Watt, Elizabeth; Peacock, Michael
Purpose: This retrospective study aims to quantify the positional accuracy of seed delivery in permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC). Methods: Treatment planning and post-implant CT scans for 5 patients were rigidly registered using the MIM Symphony™ software (MIM Software, Cleveland, OH) and used to evaluate differences between planned and implanted seed positions. Total and directional seed displacements were calculated for each patient in a clinically relevant ‘needle coordinate system’, defined relative to the angle of fiducial needle insertion. Results: The overall average total seed displacement was 10±8 mm. Systematic seed displacements weremore » observed in individual patients and the magnitude and direction of these offsets varied among patients. One patient showed a significant directional seed displacement in the shallow-deep direction compared with the other four patients. With the exception of this one patient outlier, no significant systematic directional displacements in the needle coordinate system were observed for this cohort; the average directional displacements were −1±5 mm, 2±3 mm, and −2±4 mm in the shallow-deep, up-down, and right-left directions respectively. Conclusion: With the exception of one patient outlier, the magnitude of seed displacements were relatively consistent among patients. The results indicate that the shallow-deep direction possesses the largest uncertainty for the seed delivery method used at the TBCC. The relatively large uncertainty in seed placement in this direction is expected, as this is the direction of needle insertion. Further work will involve evaluating deflections of delivered needle tracks from their planned positions.« less
Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak
2015-11-01
Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.
Wiesen, Ari J; Sideridis, Kostas; Fernandes, Angelo; Hines, Jonathan; Indaram, Anant; Weinstein, Lenny; Davidoff, Samuel; Bank, Simmy
2006-12-01
PEG is a widely used method for providing nutritional support. Although pneumoperitoneum is a known finding after PEG placement, its true incidence is subject to debate. Small retrospective studies have found varied rates of free air after PEG placement. There were a total of 65 patients. To assess the true incidence of pneumoperitoneum and its clinical significance. Prospective study. Long Island Jewish Medical Center. We obtained upright and anterior-posterior chest radiographs of 65 patients within 3 hours after PEG placement. Type of PEG tube, gauge of the needle used, number of sticks, and indications were recorded. The presence of pneumoperitoneum on the initial chest film was considered to be a positive finding. After a positive result, a repeat chest film was obtained 72 hours later to determine whether there was progression or resolution of the free air. Patients enrolled in the study were also monitored clinically for evidence of peritonitis. Of the 65 patients who underwent PEG placement, 13 developed a pneumoperitoneum on the initial chest radiograph; there was complete resolution of pneumoperitoneum at 72 hours in 10 of the 13 patients. In 3 patients, the free air persisted but was of no clinical significance. The free air was quantified by measuring the height of the air column under the diaphragm and was graded with a scoring system (0, no air; 1, small; 2, moderate; 3, large). Eleven patients who underwent PEG died during the hospitalization; none of the deaths were related to the PEG placement or pneumoperitoneum. The other 54 patients were discharged to a skilled nursing facility. No patients in the study had clinical evidence of peritonitis. There were no adverse events, ie, infection or bleeding, associated with the PEG placement in any of the patients. Our data suggest that pneumoperitoneum after PEG placement is common and, in the absence of clinical symptoms, is of no clinical significance and does not warrant any further intervention.
Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R
2013-01-01
Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.
Fast 5DOF needle tracking in iOCT.
Weiss, Jakob; Rieke, Nicola; Nasseri, Mohammad Ali; Maier, Mathias; Eslami, Abouzar; Navab, Nassir
2018-06-01
Intraoperative optical coherence tomography (iOCT) is an increasingly available imaging technique for ophthalmic microsurgery that provides high-resolution cross-sectional information of the surgical scene. We propose to build on its desirable qualities and present a method for tracking the orientation and location of a surgical needle. Thereby, we enable the direct analysis of instrument-tissue interaction directly in OCT space without complex multimodal calibration that would be required with traditional instrument tracking methods. The intersection of the needle with the iOCT scan is detected by a peculiar multistep ellipse fitting that takes advantage of the directionality of the modality. The geometric modeling allows us to use the ellipse parameters and provide them into a latency-aware estimator to infer the 5DOF pose during needle movement. Experiments on phantom data and ex vivo porcine eyes indicate that the algorithm retains angular precision especially during lateral needle movement and provides a more robust and consistent estimation than baseline methods. Using solely cross-sectional iOCT information, we are able to successfully and robustly estimate a 5DOF pose of the instrument in less than 5.4 ms on a CPU.
Piezoelectric control of needle-free transdermal drug delivery.
Stachowiak, Jeanne C; von Muhlen, Marcio G; Li, Thomas H; Jalilian, Laleh; Parekh, Sapun H; Fletcher, Daniel A
2007-12-04
Transdermal drug delivery occurs primarily through hypodermic needle injections, which cause pain, require a trained administrator, and may contribute to the spread of disease. With the growing number of pharmaceutical therapies requiring transdermal delivery, an effective, safe, and simple needle-free alternative is needed. We present and characterize a needle-free jet injector that employs a piezoelectric actuator to accelerate a micron-scale stream of fluid (40-130 microm diameter) to velocities sufficient for skin penetration and drug delivery (50-160 m/s). Existing jet injectors, powered by compressed springs and gases, are not widely used due to painful injections and poor reliability in skin penetration depth and dose. In contrast, our device offers electronic control of the actuator expansion rate, resulting in direct control of jet velocity and thus the potential for more precise injections. We apply a simple fluid-dynamic model to predict the device response to actuator expansion. Further, we demonstrate that injection parameters including expelled volume, jet pressure, and penetration depth in soft materials vary with actuator expansion rate, but are highly coupled. Finally, we discuss how electronically-controlled jet injectors may enable the decoupling of injection parameters such as penetration depth and dose, improving the reliability of needle-free transdermal drug delivery.
Megasessions for Robotic Hair Restoration.
Pereira, Joa O Carlos; Pereira Filho, Joa O Carlos; Cabrera Pereira, Joa O Pedro
2016-11-01
A robotic system can select and remove individual hair follicles from the donor area with great precision and without fatigue. This report describes the use of the robotic system in a megasession for hair restoration. Patients were instructed to cut their hair to 1.0 to 1.2 mm before surgery. The robot selected and removed 600 to 800 grafts per hour so the follicular units (FU)s could be transplanted manually to recipient sites. The robot arm consists of a sharp inner punch and a blunt outer punch which together separate FUs from the sur- rounding tissue. Stereoscopic cameras controlled by image processing software allow the system to identify the angle and direction of hair growth. The physician and one assistant control the harvesting with a hand-held remote control and computer monitor while the patient is positioned in an adjustable chair. When the robot has harvested all the FUs they are removed by technicians with small forceps. Hairline design, creation of recipient sites, and graft placement are performed manually by the physician. Clinical photographs before and after surgery show that patients experience excellent outcomes with the robotic megasession. Phy- sician fatigue during graft extraction is reduced because the robot performs the repetitive movements without fatigue. Variability of graft extraction is minimized because the robot's optical system can be programmed to choose the best FUs. The transection rate is reduced because the robot's graft extraction system uses two needles, a sharp one to piece the skin and a blunt needle to dissect the root without trauma. A robotic megasession for hair restoration is minimally invasive, does not result in linear scars in the donor area, and is associated with minimal fatigue and discomfort for both patient and physician. Healing is rapid and patients experience a high level of satisfaction with the results. J Drugs Dermatol. 2016;15(11):1407-1412..
Bergmann, P; Huber, S; Segl, H; Maechler, H; Reiter, U; Reiter, G; Rienmueller, R; Oberwalder, P; Rigler, B
2003-08-01
The identification of the ideal anastomosis site and the proper port placement are critical for the success of closed-chest robotic surgery. We investigated a new systematic procedure for precise port placement for TECABs. We used trigonometry and a human thoracic model to determine the optimal working angles between anastomotic plane, instruments, and endoscope. We then applied the results to seven human subjects as follows: 1. A navigation grid was located extrathoracically before cardiac MR examination. 2. The ideal anastomosis site was defined with the MR. Intrathoracic distances and angles were computed with cardiac MR software and projected onto the thorax. 3. The ideal port placement points were marked on the thorax. The optimal working angle between endoscope and instruments was 35 degrees. 0 degrees and 90 degrees angles were associated with a significant reduction in visualization, technical ease, quality and anastomosis time. The course of the LAD was identified in all seven volunteers with MR. Mean deviation of the endoscope port from the medioclavicular line was 4.3+/-2.1 cm and of the instrument ports from the anterior axillary line 8.4+/-2.4 cm. Cardiac MR in combination with the navigation grid proved suitable for the visualization of coronary vessels for individually calculating port placement points on the thorax.
Recent advances in topical anesthesia
2016-01-01
Topical anesthetics act on the peripheral nerves and reduce the sensation of pain at the site of application. In dentistry, they are used to control local pain caused by needling, placement of orthodontic bands, the vomiting reflex, oral mucositis, and rubber-dam clamp placement. Traditional topical anesthetics contain lidocaine or benzocaine as active ingredients and are used in the form of solutions, creams, gels, and sprays. Eutectic mixtures of local anesthesia cream, a mixture of various topical anesthetics, has been reported to be more potent than other anesthetics. Recently, new products with modified ingredients and application methods have been introduced into the market. These products may be used for mild pain during periodontal treatment, such as scaling. Dentists should be aware that topical anesthetics, although rare, might induce allergic reactions or side effects as a result of an overdose. Topical anesthetics are useful aids during dental treatment, as they reduce dental phobia, especially in children, by mitigating discomfort and pain. PMID:28879311
A simple method for long-term biliary access in large animals.
Andrews, J C; Knutsen, C; Smith, P; Prieskorn, D; Crudip, J; Klevering, J; Ensminger, W D
1988-07-01
A simple method to obtain long-term access to the biliary tree in dogs and pigs is presented. In ten dogs and four pigs, a cholecystectomy was performed, the cystic duct isolated, and a catheter inserted into the cut end of the cystic duct. The catheter was connected to a subcutaneous infusion port, producing a closed, internal system to allow long-term access. The catheter placement was successful in three of the pigs and all of the dogs. Thirty-five cholangiograms were obtained in the 13 subjects by accessing the port with a 20 gauge Huber needle and injecting small amounts (4-10 mL) of contrast under fluoroscopic control. Cholangiograms were obtained up to four months after catheter placement without evidence for catheter failure or surgically induced changes in the biliary tree. This model provides a simple, reliable means to obtain serial cholangiograms in a research setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, P; Kapoor, R; Curran, B
Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work,more » two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.« less
Ristev, Goran; Sipes, Angela C; Mahoney, Bryan; Lipps, Jonathan; Chan, Gary; Coffman, John C
2017-01-01
Background The rationale for injection of epidural medications through the needle is to promote sooner onset of pain relief relative to dosing through the epidural catheter given that needle injection can be performed immediately after successful location of the epidural space. Some evidence indicates that dosing medications through the epidural needle results in faster onset and improved quality of epidural anesthesia compared to dosing through the catheter, though these dosing techniques have not been compared in laboring women. This investigation was performed to determine whether dosing medication through the epidural needle improves the quality of analgesia, level of sensory blockade, or onset of pain relief measured from the time of epidural medication injection. Methods In this double-blinded prospective investigation, healthy term laboring women (n=60) received labor epidural placement upon request. Epidural analgesia was initiated according to the assigned randomization group: 10 mL loading dose (0.125% bupivacaine with fentanyl 2 µg/mL) through either the epidural needle or the catheter, given in 5 mL increments spaced 2 minutes apart. Verbal rating scale (VRS) pain scores (0–10) and pinprick sensory levels were documented to determine the rates of analgesic and sensory blockade onset. Results No significant differences were observed in onset of analgesia or sensory blockade from the time of injection between study groups. The estimated difference in the rate of pain relief (VRS/minute) was 0.04 (95% CI: −0.01 to 0.11; p=0.109), and the estimated difference in onset of sensory blockade (sensory level/minute) was 0.63 (95% CI: −0.02 to 0.15; p=0.166). The time to VRS ≤3 and level of sensory block 20 minutes after dosing were also similar between groups. No differences in patient satisfaction, or maternal or fetal complications were observed. Conclusion This investigation observed that epidural needle and catheter injection of medications result in similar onset of analgesia and sensory blockade, quality of labor analgesia, patient satisfaction, and complication rates. PMID:29263693
Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F
2013-12-01
Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (<20 previous UGRA experience) were randomly assigned to perform a UGRA task on 1 of 3 models-the transparent, opaque, and OCB models, where the hyperechoic target was identified, a needle was advanced to it under ultrasound guidance, fluid was injected, and images were saved. We recorded the errors during task completion, number of attempts and needle passes, and the time for target identification and needle placement until the predetermined benchmark of 3 consecutive successful UGRA simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryu, Bon; Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario; Bax, Jeff
2012-08-01
Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects' 3D TRUS images showing a maximum PAI of {<=}1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, allmore » subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15 Degree-Sign were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of {<=}80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom with 23% PAI by volume.« less
NASA Astrophysics Data System (ADS)
Filippatos, Konstantinos; Boehler, Tobias; Geisler, Benjamin; Zachmann, Harald; Twellmann, Thorsten
2010-02-01
With its high sensitivity, dynamic contrast-enhanced MR imaging (DCE-MRI) of the breast is today one of the first-line tools for early detection and diagnosis of breast cancer, particularly in the dense breast of young women. However, many relevant findings are very small or occult on targeted ultrasound images or mammography, so that MRI guided biopsy is the only option for a precise histological work-up [1]. State-of-the-art software tools for computer-aided diagnosis of breast cancer in DCE-MRI data offer also means for image-based planning of biopsy interventions. One step in the MRI guided biopsy workflow is the alignment of the patient position with the preoperative MR images. In these images, the location and orientation of the coil localization unit can be inferred from a number of fiducial markers, which for this purpose have to be manually or semi-automatically detected by the user. In this study, we propose a method for precise, full-automatic localization of fiducial markers, on which basis a virtual localization unit can be subsequently placed in the image volume for the purpose of determining the parameters for needle navigation. The method is based on adaptive thresholding for separating breast tissue from background followed by rigid registration of marker templates. In an evaluation of 25 clinical cases comprising 4 different commercial coil array models and 3 different MR imaging protocols, the method yielded a sensitivity of 0.96 at a false positive rate of 0.44 markers per case. The mean distance deviation between detected fiducial centers and ground truth information that was appointed from a radiologist was 0.94mm.
Motorized fusion guided prostate biopsy: phantom study
NASA Astrophysics Data System (ADS)
Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.
2017-03-01
Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target 1, 2, and 3, respectively. The mechanical error was 0.75+/-0.4 mm, 0.45+/-0.4 mm, and 0.55+/-0.4 mm, for free hand approach while it was 1.0+/-0.57 mm, 0.45+/-0.4 mm, and 0.35+/-0.25 mm, for motorized approach, for target 1, 2, and 3, respectively. PPMCC remained almost at 1.0 for the motorized approach while having a variation between 0.9 and 1.0 for the free hand approach. Conclusions: motorized fusion guided prostate biopsy in a phantom study was feasible and non-inferior or comparable to the free hand manual approach in terms of accuracy and speed of targeting, while being superior in terms of repeatability and steadiness.
NASA Astrophysics Data System (ADS)
Daghighi, Yasaman; Heidari, Hossein; Taylor, Hayden
2018-02-01
A predominant unsolved challenge in tissue engineering is the need of a robust technique for producing vascular networks, particularly when modeling human brain tissue. The availability of reliable in vitro human brain microvasculature models would advance our understanding of its function and would provide a platform for highthroughput drug screening. Current strategies for modeling vascularized brain tissue suffer from limitations such as (1) culturing non-human cell lines, (2) limited multi-cell co-culture, and (3) the effects of neighboring physiologically unrealistic rigid polymeric surfaces, such as solid membranes. We demonstrate a new micro-engineered platform that can address these shortcomings. Specifically, we have designed and prototyped a molding system to enable the precise casting of 100μm-diameter coaxial hydrogel structures laden with the requisite cells to mimic a vascular lumen. Here we demonstrate that a fine wire with diameter 130 μm or a needle with outer diameter 300 μm can be used as a temporary mold insert, and agarose-collagen composite matrix can be cast around these inserts and thermally gelled. When the wire or needle is retracted under the precise positional control afforded by our system, a microchannel is formed which is then seeded with human microvascular endothelial cells. After seven days of culture these cells produce an apparently confluent monolayer on the channel walls. In principle, this platform could be used to create multilayered cellular structures. By arranging a fine wire and a hollow needle coaxially, three distinct zones could be defined in the model: first, the bulk gel surrounding the needle; then, after needle retraction, a cylindrical shell of matrix; and finally, after retraction of the wire, a lumen. Each zone could be independently cell-seeded. To this end, we have also successfully 3D cultured human astrocytes and SY5Y glial cells in our agarose-collagen matrix. Our approach ultimately promises scalable and repeatable production of vascular structures with physiologically realistic mechanical properties.
Advanced CD-SEM solution for edge placement error characterization of BEOL pitch 32nm metal layers
NASA Astrophysics Data System (ADS)
Charley, A.; Leray, P.; Lorusso, G.; Sutani, T.; Takemasa, Y.
2018-03-01
Metrology plays an important role in edge placement error (EPE) budgeting. Control for multi-patterning applications as new critical distances needs to be measured (edge to edge) and requirements become tighter and tighter in terms of accuracy and precision. In this paper we focus on imec iN7 BEOL platform and particularly on M2 patterning scheme using SAQP + block EUV for a 7.5 track logic design. Being able to characterize block to SAQP edge misplacement is important in a budgeting exercise (1) but is also extremely difficult due to challenging edge detection with CD-SEM (similar materials, thin layers, short distances, 3D features). In this study we develop an advanced solution to measure block to SAQP placement, we characterize it in terms of sensitivity, precision and accuracy through the comparison to reference metrology. In a second phase, the methodology is applied to budget local effects and the results are compared to the characterization of the SAQP and block independently.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its positionmore » and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Interactions of the plasma needle with cells in culture
NASA Astrophysics Data System (ADS)
Stoffels, E.; Broers, J. L. V.; Kunts, S.; Cornelis, R. A. A.; Caubet, V.; Ramaekers, F. C. S.
2002-10-01
A non-thermal atmospheric plasma source (plasma needle) has been developed. This plasma operates at room temperature, low voltages and power levels, so it can be applied for fine treatment of organic material. In this work the impact of the plasma needle on living cells is explored. For this purpose CHO-K1 (Chinese hamster ovary) cells in culture have been plasma-treated and their responses have been recorded by means of propidium iodide staining. Plasma treatment at low to intermediate power levels leads to damage of the DNA in the cell nucleus, which causes cell death. Characteristic features are high precision of plasma action (influenced cells are strictly localized) and induction of cell death without destroying the cell integrity. Possibilities of using plasma treatment for removal of unwanted cells (e.g. cancer cells) will be investigated.
Chung, Amanda S. J.; Suarez, Oscar A.
2017-01-01
The AdVance sling (American Medical Systems, Minnetonka, MN, United States of America) is a synthetic transobturator sling, which is a safe and effective minimally invasive treatment for mild to moderate stress urinary incontinence (SUI) in male patients. This article provides a step-by-step description of our technique for placement of the AdVance male sling, including details and nuances gained from surgical experience, advice for avoidance of complications and discussion on management of complications and sling failures. Patient selection is very important, including exclusion and preoperative treatment of urethral stenosis and bladder dysfunction. Previous pelvic radiation is a poor prognostic factor. In brief, the steps of sling placement are: (I) mobilization of the corpus spongiosum (CS); (II) marking and mobilization of the central tendon; (III) passage of the helical trocar needles exiting at the apex of the angle between the CS and inferior pubic ramus; (IV) fixation of the broad part of the sling body to the CS at the previous mark; (V) cystoscopy during sling tensioning; (VI) placement of a Foley urethral catheter; (VII) Subcutaneous tunnelling of the sling arms back toward the midline; (VIII) wound closure. The most common early postoperative complication is urinary retention but long-term retention is extremely rare. Management of sling failures include placement of an artificial urinary sphincter, repeat AdVance sling, urethral bulking agent or ProACT device. PMID:28904900
Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.
Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O
2009-04-01
Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.
The missed inferior alveolar block: a new look at an old problem.
Milles, M
1984-01-01
A variation of a previously described technique to obtain mandibular block anesthesia is presented. This technique varies from those previously described in that is uses palpable anatomic landmarks, both extra- and intraoral, to orient the placement of the needle. This technique relies on several readily observed landmarks and the integration of these landmarks. Because palpable landmarks are used, consistent results can be easily obtained even in patients who present with a wide variety of anatomical variances which otherwise make this injection technique difficult and prone to failure.
Moving the Needle: Simulation's Impact on Patient Outcomes.
Cox, Tiffany; Seymour, Neal; Stefanidis, Dimitrios
2015-08-01
This review investigates the available literature that addresses the impact simulator training has on patient outcomes. The authors conducted a comprehensive literature search of studies reporting outcomes of simulation training and categorized studies based on the Kirkpatrick model of training evaluation. Kirkpatrick level 4 studies reporting patient outcomes were identified and included in this review. Existing evidence is promising, demonstrating patient benefits as a result of simulation training for central line placement, obstetric emergencies, cataract surgery, laparoscopic inguinal hernia repair, and team training. Copyright © 2015 Elsevier Inc. All rights reserved.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures.
Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S
2017-08-01
This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.
Augmented reality system for CT-guided interventions: system description and initial phantom trials
NASA Astrophysics Data System (ADS)
Sauer, Frank; Schoepf, Uwe J.; Khamene, Ali; Vogt, Sebastian; Das, Marco; Silverman, Stuart G.
2003-05-01
We are developing an augmented reality (AR) image guidance system, in which information derived from medical images is overlaid onto a video view of the patient. The interventionalist wears a head-mounted display (HMD) that presents him with the augmented stereo view. The HMD is custom fitted with two miniature color video cameras that capture the stereo view of the scene. A third video camera, operating in the near IR, is also attached to the HMD and is used for head tracking. The system achieves real-time performance of 30 frames per second. The graphics appears firmly anchored in the scne, without any noticeable swimming or jitter or time lag. For the application of CT-guided interventions, we extended our original prototype system to include tracking of a biopsy needle to which we attached a set of optical markers. The AR visualization provides very intuitive guidance for planning and placement of the needle and reduces radiation to patient and radiologist. We used an interventional abdominal phantom with simulated liver lesions to perform an inital set of experiments. The users were consistently able to locate the target lesion with the first needle pass. These results provide encouragement to move the system towards clinical trials.
A Novel Technique of Posterolateral Suturing in Thoracoscopic Diaphragmatic Hernia Repair
Boo, Yoon Jung; Rohleder, Stephan; Muensterer, Oliver J.
2017-01-01
Background Closure of the posterolateral defect in some cases of congenital diaphragmatic hernia (CDH) can be difficult. Percutaneous transcostal suturing is often helpful to create a complete, watertight closure of the diaphragm. A challenge with the technique is passing the needle out the same tract that it entered so that no skin is caught when the knots are laid down into the subcutaneous tissue. This report describes a novel technique using a Tuohy needle to percutaneously suture the posterolateral defect during thoracoscopic repair of CDH. Case We report a case of a 6-week-old infant who presented with a CDH and ipsilateral intrathoracic kidney that was repaired using thoracoscopic approach. The posterolateral part of the defect was repaired by percutaneous transcostal suturing and extracorporeal knot tying. To assure correct placement of the sutures and knots, a Tuohy needle was used to guide the suture around the rib and out through the same subcutaneous tract. The total operative time was 145 minutes and there were no perioperative complications. The patient was followed up for 3 months, during which there was no recurrence. Conclusion Our percutaneous Tuohy technique for closure of the posterolateral part of CDH enables a secure, rapid, and tensionless repair. PMID:28804698
A Novel Technique of Posterolateral Suturing in Thoracoscopic Diaphragmatic Hernia Repair.
Boo, Yoon Jung; Rohleder, Stephan; Muensterer, Oliver J
2017-01-01
Background Closure of the posterolateral defect in some cases of congenital diaphragmatic hernia (CDH) can be difficult. Percutaneous transcostal suturing is often helpful to create a complete, watertight closure of the diaphragm. A challenge with the technique is passing the needle out the same tract that it entered so that no skin is caught when the knots are laid down into the subcutaneous tissue. This report describes a novel technique using a Tuohy needle to percutaneously suture the posterolateral defect during thoracoscopic repair of CDH. Case We report a case of a 6-week-old infant who presented with a CDH and ipsilateral intrathoracic kidney that was repaired using thoracoscopic approach. The posterolateral part of the defect was repaired by percutaneous transcostal suturing and extracorporeal knot tying. To assure correct placement of the sutures and knots, a Tuohy needle was used to guide the suture around the rib and out through the same subcutaneous tract. The total operative time was 145 minutes and there were no perioperative complications. The patient was followed up for 3 months, during which there was no recurrence. Conclusion Our percutaneous Tuohy technique for closure of the posterolateral part of CDH enables a secure, rapid, and tensionless repair.
Chuang, Marc; Orvieto, Marcelo; Laven, Brett; Gerber, Glenn; Wardrip, Craig; Ritch, Chad; Shalhav, Arieh
2005-03-01
We sought to compare the outcomes of two chronic vascular access techniques, the externalized catheter and the subcutaneous vascular access port, in pigs. Female farm pigs (n = 30) underwent placement of a chronic vascular access device in the jugular vein for a research protocol: 18 of the animals underwent placement of a tunneled Hickman catheter (THC), and the remaining 12 animals underwent placement of a subcutaneous vascular access port (VAP) without external components. After placement of the devices, animals underwent serial blood sampling. All animals were given identical antibiotic prophylaxis. VAP access required the use of a restraint sling for Huber needle insertion, whereas THC access required no additional equipment. Animals were euthanatized 1 month after placement of the device. In the VAP group, the port was retrieved, cleaned, and steam-autoclaved for reuse. In the THC group, 13 (72%) animals developed infectious complications, and blood and wound cultures were often polymicrobial. One animal was euthanatized secondary to overwhelming sepsis. In addition, three (17%) animals developed thromboembolic complications. In contrast, no thromboembolic complications were noted in the VAP group, and only one animal developed a transient fever which resolved spontaneously; no septic complications or abscesses developed. Blood draws with no anesthesia were successful in both groups. We conclude that subcutaneous vascular access ports are a safe and efficient method for obtaining reliable chronic vascular access for a 1-month period in pigs. The subcutaneous devices were associated with low morbidity. In contrast, externalized catheters can be associated with considerable morbidity.
Autonomous Rover Traverse and Precise Arm Placement on Remotely Designated Targets
NASA Technical Reports Server (NTRS)
Nesnas, Issa A.; Pivtoraiko, Mihail N.; Kelly, Alonzo; Fleder, Michael
2012-01-01
This software controls a rover platform to traverse rocky terrain autonomously, plan paths, and avoid obstacles using its stereo hazard and navigation cameras. It does so while continuously tracking a target of interest selected from 10 20 m away. The rover drives and tracks the target until it reaches the vicinity of the target. The rover then positions itself to approach the target, deploys its robotic arm, and places the end effector instrument on the designated target to within 2-3-cm accuracy of the originally selected target. This software features continuous navigation in a fairly rocky field in an outdoor environment and the ability to enable the rover to avoid large rocks and traverse over smaller ones. Using point-and-click mouse commands, a scientist designates targets in the initial imagery acquired from the rover s mast cameras. The navigation software uses stereo imaging, traversability analysis, path planning, trajectory generation, and trajectory execution. It also includes visual target tracking of a designated target selected from 10 m away while continuously navigating the rocky terrain. Improvements in this design include steering while driving, which uses continuous curvature paths. There are also several improvements to the traversability analyzer, including improved data fusion of traversability maps that result from pose estimation uncertainties, dealing with boundary effects to enable tighter maneuvers, and handling a wider range of obstacles. This work advances what has been previously developed and integrated on the Mars Exploration Rovers by using algorithms that are capable of traversing more rock-dense terrains, enabling tight, thread-the-needle maneuvers. These algorithms were integrated on the newly refurbished Athena Mars research rover, and were fielded in the JPL Mars Yard. Forty-three runs were conducted with targets at distances ranging from 5 to 15 m, and a success rate of 93% was achieved for placement of the instrument within 2-3 cm of the target.
CT fluoroscopy-guided robotically-assisted lung biopsy
NASA Astrophysics Data System (ADS)
Xu, Sheng; Fichtinger, Gabor; Taylor, Russell H.; Banovac, Filip; Cleary, Kevin
2006-03-01
Lung biopsy is a common interventional radiology procedure. One of the difficulties in performing the lung biopsy is that lesions move with respiration. This paper presents a new robotically assisted lung biopsy system for CT fluoroscopy that can automatically compensate for the respiratory motion during the intervention. The system consists of a needle placement robot to hold the needle on the CT scan plane, a radiolucent Z-frame for registration of the CT and robot coordinate systems, and a frame grabber to obtain the CT fluoroscopy image in real-time. The CT fluoroscopy images are used to noninvasively track the motion of a pulmonary lesion in real-time. The position of the lesion in the images is automatically determined by the image processing software and the motion of the robot is controlled to compensate for the lesion motion. The system was validated under CT fluoroscopy using a respiratory motion simulator. A swine study was also done to show the feasibility of the technique in a respiring animal.
de Souza Melo, Marcelo Rodrigo; Sabey, Mark Jon Santana; Lima, Carla Juliane; de Almeida Souza, Liane Maciel; Groppo, Francisco Carlos
2015-01-01
This randomized double-blind crossover trial investigated the discomfort associated with 2 injection speeds, low (60 seconds) and slow (100 seconds), during inferior alveolar nerve block by using 1.8 mL of 2% lidocaine with 1 : 100,000 epinephrine. Three phases were considered: (a) mucosa perforation, (b) needle insertion, and (c) solution injection. Thirty-two healthy adult volunteers needing bilateral inferior alveolar nerve blocks at least 1 week apart were enrolled in the present study. The anesthetic procedure discomfort was recorded by volunteers on a 10-cm visual analog scale in each phase for both injection speeds. Comparison between the 2 anesthesia speeds in each phase was performed by paired t test. Results showed no statistically significant difference between injection speeds regarding perforation (P = .1016), needle placement (P = .0584), or speed injection (P = .1806). The discomfort in all phases was considered low. We concluded that the 2 injection speeds tested did not affect the volunteers' pain perception during inferior alveolar nerve blocks.
Target motion tracking in MRI-guided transrectal robotic prostate biopsy.
Tadayyon, Hadi; Lasso, Andras; Kaushal, Aradhana; Guion, Peter; Fichtinger, Gabor
2011-11-01
MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this paper: 1) is rigid registration sufficient in tracking the targets with an error smaller than the clinically significant size of prostate cancer and 2) what is the effect of the number of intraoperative slices on registration accuracy and speed? we propose multislice-to-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intraoperative slices are acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Both rigid and deformable scenarios were implemented. Both simulated and clinical MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. average registration errors in clinical patient data were 2.6 mm for the rigid algorithm and 2.1 mm for the deformable algorithm. rigid tracking appears to be promising. Three tracking slices yield significantly high registration speed with an affordable error.
Method and system for providing autonomous control of a platform
NASA Technical Reports Server (NTRS)
Seelinger, Michael J. (Inventor); Yoder, John-David (Inventor)
2012-01-01
The present application provides a system for enabling instrument placement from distances on the order of five meters, for example, and increases accuracy of the instrument placement relative to visually-specified targets. The system provides precision control of a mobile base of a rover and onboard manipulators (e.g., robotic arms) relative to a visually-specified target using one or more sets of cameras. The system automatically compensates for wheel slippage and kinematic inaccuracy ensuring accurate placement (on the order of 2 mm, for example) of the instrument relative to the target. The system provides the ability for autonomous instrument placement by controlling both the base of the rover and the onboard manipulator using a single set of cameras. To extend the distance from which the placement can be completed to nearly five meters, target information may be transferred from navigation cameras (used for long-range) to front hazard cameras (used for positioning the manipulator).
Simplified stereo-optical ultrasound plane calibration
NASA Astrophysics Data System (ADS)
Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan
2013-03-01
Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke
CT-Guided Interventions Using a Free-Hand, Optical Tracking System: Initial Clinical Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubert, Tilman, E-mail: TSchubert@uhbs.ch; Jacob, Augustinus L.; Pansini, Michele
2013-08-01
PurposeThe present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system.MethodsFifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane.ResultsNinety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targetingmore » precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target.ConclusionsThe application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.« less
NASA Astrophysics Data System (ADS)
Kim, Younsu; Kim, Sungmin; Boctor, Emad M.
2017-03-01
An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.
Rochlen, Lauryn R.; Levine, Robert; Tait, Alan R.
2016-01-01
Introduction The value of simulation in medical education and procedural skills training is well recognized. Despite this, many mannequin-based trainers are limited by the inability of the trainee to view the internal anatomical structures. This study evaluates the usability and feasibility of a 1st person point of view (POV) augmented reality (AR) trainer on needle insertion as a component of central venous catheter (CVC) placement. Methods Forty subjects, including medical students and anesthesiology residents and faculty participated. AR glasses were provided through which the relevant internal anatomical landmarks were projected. Following a practice period, participants were asked to place the needle in the mannequin without the benefit of the AR projected internal anatomy. The ability of the trainees to correctly place the needle was documented. Participants also completed a short survey describing their perceptions of the AR technology. Results Participants reported that the AR technology was realistic (77.5%) and that the ability to view the internal anatomy was helpful (92.5%). Furthermore, 85% and 82.1%, respectively, believed that the AR technology promoted learning and should be incorporated into medical training. The ability to successfully place the needle was similar between experienced and non-experienced participants, however, less experienced participants were more likely to inadvertently puncture the carotid artery. Conclusions Results of this pilot study demonstrated the usability and feasibility of AR technology as a potentially important adjunct to simulated medical skills training. Further development and evaluation of this innovative technology under a variety of simulated medical training settings would be an important next step. PMID:27930431
Rochlen, Lauryn R; Levine, Robert; Tait, Alan R
2017-02-01
The value of simulation in medical education and procedural skills training is well recognized. Despite this, many mannequin-based trainers are limited by the inability of the trainee to view the internal anatomical structures. This study evaluates the usability and feasibility of a first-person point-of-view-augmented reality (AR) trainer on needle insertion as a component of central venous catheter placement. Forty subjects, including medical students and anesthesiology residents and faculty, participated. Augmented reality glasses were provided through which the relevant internal anatomical landmarks were projected. After a practice period, participants were asked to place the needle in the mannequin without the benefit of the AR-projected internal anatomy. The ability of the trainees to correctly place the needle was documented. Participants also completed a short survey describing their perceptions of the AR technology. Participants reported that the AR technology was realistic (77.5%) and that the ability to view the internal anatomy was helpful (92.5%). Furthermore, 85% and 82.1%, respectively, believed that the AR technology promoted learning and should be incorporated into medical training. The ability to successfully place the needle was similar between experienced and nonexperienced participants; however, less experienced participants were more likely to inadvertently puncture the carotid artery. Results of this pilot study demonstrated the usability and feasibility of AR technology as a potentially important adjunct to simulated medical skills training. Further development and evaluation of this innovative technology under a variety of simulated medical training settings would be an important next step.
Needle aspiration versus intercostal tube drainage for pneumothorax in the newborn.
Bruschettini, Matteo; Romantsik, Olga; Ramenghi, Luca Antonio; Zappettini, Simona; O'Donnell, Colm P F; Calevo, Maria Grazia
2016-01-11
Pneumothorax occurs more frequently in the neonatal period than at any other time of life and is associated with increased mortality and morbidity. It may be treated with either needle aspiration or insertion of a chest tube. The former consists of aspiration of air with a syringe through a needle or an angiocatheter, usually through the second or third intercostal space in the midclavicular line. The chest tube is usually placed in the anterior pleural space passing through the sixth intercostal space into the pleural opening, turned anteriorly and directed to the location of the pneumothorax, and then connected to a Heimlich valve or an underwater seal with continuous suction. To compare the efficacy and safety of needle aspiration and intercostal tube drainage in the management of neonatal pneumothorax. We used the standard search strategy of the Cochrane Neonatal Review group to search the Cochrane Central Register of Controlled Trials (CENTRAL 2015, Issue 11), MEDLINE via PubMed (1966 to 30 November 2015), EMBASE (1980 to 30 November 2015), and CINAHL (1982 to 30 November 2015). We also searched clinical trials databases, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. Randomised controlled trials, quasi-randomised controlled trials and cluster trials comparing needle aspiration (either with the needle or angiocatheter left in situ or removed immediately after aspiration) to intercostal tube drainage in newborn infants with pneumothorax. For each of the included trial, two authors independently extracted data (e.g. number of participants, birth weight, gestational age, kind of needle and chest tube, choice of intercostal space, pressure and device for drainage) and assessed the risk of bias (e.g. adequacy of randomisation, blinding, completeness of follow-up). The primary outcomes considered in this review are mortality during the neonatal period and during hospitalisation. One randomised controlled trial (72 infants) met the inclusion criteria of this review. We found no differences in the rates of mortality (risk ratio (RR) 1.50, 95% confidence interval (CI) 0.27 to 8.45) or complications related to the procedure. After needle aspiration, the angiocatheter was left in situ (mean 27.1 hours) and not removed immediately after the aspiration. The angiocatheter was in place for a shorter duration than the intercostal tube (mean difference (MD) -11.20 hours, 95% CI -15.51 to -6.89). None of the 36 newborns treated with needle aspiration with the angiocatheter left in situ required the placement of an intercostal tube drainage. Overall, the quality of the evidence supporting this finding is low. At present there is insufficient evidence to determine the efficacy and safety of needle aspiration versus intercostal tube drainage in the management of neonatal pneumothorax. Randomised controlled trials comparing the two techniques are warranted.
Parent, Francois; Loranger, Sebastien; Mandal, Koushik Kanti; Iezzi, Victor Lambin; Lapointe, Jerome; Boisvert, Jean-Sébastien; Baiad, Mohamed Diaa; Kadoury, Samuel; Kashyap, Raman
2017-04-01
We demonstrate a novel approach to enhance the precision of surgical needle shape tracking based on distributed strain sensing using optical frequency domain reflectometry (OFDR). The precision enhancement is provided by using optical fibers with high scattering properties. Shape tracking of surgical tools using strain sensing properties of optical fibers has seen increased attention in recent years. Most of the investigations made in this field use fiber Bragg gratings (FBG), which can be used as discrete or quasi-distributed strain sensors. By using a truly distributed sensing approach (OFDR), preliminary results show that the attainable accuracy is comparable to accuracies reported in the literature using FBG sensors for tracking applications (~1mm). We propose a technique that enhanced our accuracy by 47% using UV exposed fibers, which have higher light scattering compared to un-exposed standard single mode fibers. Improving the experimental setup will enhance the accuracy provided by shape tracking using OFDR and will contribute significantly to clinical applications.
Microwave ablation of pulmonary malignancies using a novel high-energy antenna system.
Little, Mark W; Chung, Daniel; Boardman, Philip; Gleeson, Fergus V; Anderson, Ewan M
2013-04-01
To evaluate the technical success, safety, and imaging follow-up of malignant pulmonary nodules treated with a novel high-energy percutaneous microwave ablation (MWA) system. Between July 2010 and September 2011, a total of 23 patients, 12 men, mean age 68 (range 30-87) years with 29 pulmonary malignancies of median diameter 19 (range 8-57) mm, underwent computed tomography (CT)-guided MWA with a 16G microwave needle antenna enabling power up to 180 W. Technical success was defined as needle placement in the intended lesion without death or serious injury. Adequacy of ablation was assessed at 24 h on contrast-enhanced CT. Circumferential solid or ground glass opacification >5 mm was used to define an ideal ablation. Local tumor recurrence was assessed at 1, 3, and 6 months after ablation on contrast-enhanced CT. MWA was technically successful in 93 % (n = 27). Mean ablation duration was 3.6 (range 1-9) min. Ten patients (43 %) developed a pneumothorax as a result of the MWA; only 3 (13 %) required placement of a chest drain. Thirty-day mortality rate was 0 %. The mean hospital stay was 1.5 (range 1-7) days. A total of 22 lesions (75 %) were surrounded by ≥5 mm ground glass or solid opacification after the procedure. At a median follow-up of 6 months, local recurrence was identified in 3 out of 26 lesions, giving a local control rate of 88 %. MWA using a high-power antenna of pulmonary malignancies is safe, technically achievable, and enables fast ablation times.
Follow-up of negative MRI-targeted prostate biopsies: when are we missing cancer?
Gold, Samuel A; Hale, Graham R; Bloom, Jonathan B; Smith, Clayton P; Rayn, Kareem N; Valera, Vladimir; Wood, Bradford J; Choyke, Peter L; Turkbey, Baris; Pinto, Peter A
2018-05-21
Multiparametric magnetic resonance imaging (mpMRI) has improved clinicians' ability to detect clinically significant prostate cancer (csPCa). Combining or fusing these images with the real-time imaging of transrectal ultrasound (TRUS) allows urologists to better sample lesions with a targeted biopsy (Tbx) leading to the detection of greater rates of csPCa and decreased rates of low-risk PCa. In this review, we evaluate the technical aspects of the mpMRI-guided Tbx procedure to identify possible sources of error and provide clinical context to a negative Tbx. A literature search was conducted of possible reasons for false-negative TBx. This includes discussion on false-positive mpMRI findings, termed "PCa mimics," that may incorrectly suggest high likelihood of csPCa as well as errors during Tbx resulting in inexact image fusion or biopsy needle placement. Despite the strong negative predictive value associated with Tbx, concerns of missed disease often remain, especially with MR-visible lesions. This raises questions about what to do next after a negative Tbx result. Potential sources of error can arise from each step in the targeted biopsy process ranging from "PCa mimics" or technical errors during mpMRI acquisition to failure to properly register MRI and TRUS images on a fusion biopsy platform to technical or anatomic limits on needle placement accuracy. A better understanding of these potential pitfalls in the mpMRI-guided Tbx procedure will aid interpretation of a negative Tbx, identify areas for improving technical proficiency, and improve both physician understanding of negative Tbx and patient-management options.
Dua, Kulwinder S; Latif, Sahibzada U; Yang, Juliana F; Fang, Tom C; Khan, Abdul; Oh, Young
2014-10-01
Fully covered esophageal self-expandable metal stents (SEMSs) are potentially removable but can be associated with high migration rates. For precise positioning, non-foreshortening SEMSs are preferred. Recently, a new fully covered non-foreshortening SEMS with anti-migration features was introduced. To evaluate the efficacy and safety of this new esophageal SEMS. Retrospective study. Single, tertiary-care center. Consecutive patients with malignant and benign strictures with dysphagia grade of ≥3 and patients with fistulas/leaks were studied. Stent placement and removal. Technical success in stent deployment/removal, efficacy in relieving dysphagia and sealing fistulas/leaks, and adverse events. Forty-three stents were placed in 35 patients (mean [± standard deviation] age 65 ± 11 years; 31 male), 24 for malignant and 11 for benign (5 strictures, 6 leaks) indications. Technical success in precise SEMS placement was 100%. The after-stent dysphagia grade improved significantly (at 1 week: 1.5 ± 0.7; at 4 weeks: 1.2 ± 0.4; baseline: 3.8 ± 0.4; P < .0001). Twenty stents were removed for clinical indications, with technical success of 100%. All leaks sealed after SEMS placement and did not recur after stent removal. All benign strictures recurred after stent removal. Adverse events included migration (14%), chest pain (11%), and dysphagia from tissue hyperplasia (6%). There was no stent-related mortality. Nonrandomized, single-center study. The new esophageal SEMS was effective in relieving malignant dysphagia, allowed for precise placement, and was easily removable. It was effective in treating benign esophageal fistulas and leaks. Stent-related adverse events were acceptable. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Updated tops file for Cretaceous and lower Tertiary units, Piceance Basin, northwest Colorado
Johnson, Ronald C.; Dietrich, John D.; Mercier, Tracey J.
2015-08-04
Each entry for the base of the Long Point Bed was obtained at a location where the mapped Long Point Bed intersects a contour line on the published maps. Precision of each elevation is therefore dependent on the precision of the maps and the placement of the mapped contact by the authors.
An investigation into non-invasive physical activity recognition using smartphones.
Kelly, Daniel; Caulfield, Brian
2012-01-01
Technology utilized to automatically monitor Activities of Daily Living (ADL) could be a key component in identifying deviations from normal functional profiles and providing feedback on interventions aimed at improving health. However, if activity recognition systems are to be implemented in real world scenarios such as health and wellness monitoring, the activity sensing modality must unobtrusively fit the human environment rather than forcing humans to adhere to sensor specific conditions. Modern smart phones represent a ubiquitous computing device which has already undergone mainstream adoption. In this paper, we investigate the feasibility of using a modern smartphone, with limited placement constraints, as the sensing modality for an activity recognition system. A dataset of 4 subjects performing 7 activities, using varying sensor placement conditions, is utilized to investigate this. Initial experiments show that a decision tree classifier performs activity classification with precision and recall scores of 0.75 and 0.73 respectively. More importantly, as part of this initial experiment, 3 main problems, and subsequently 3 solutions, relating to unconstrained sensor placement were identified. Using our proposed solutions, classification precision and recall scores were improved by +13% and +14.6% respectively.
MO-G-17A-09: Quantitative Autoradiography of Biopsy Specimens Extracted Under PET/CT Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanchon, L; Carlin, S; Schmidtlein, C
2014-06-15
Purpose: To develop a procedure for accurate determination of PET tracer concentration with high spatial accuracy in situ by performing Quantitative Autoradiography of Biopsy Specimens (QABS) extracted under PET/CT guidance. Methods: Autoradiography (ARG) standards were produced from a gel loaded with a known concentration of FDG biopsied with 18G and 20G biopsy needles. Specimens obtained with these needles are generally cylindrical: up to 18 mm in length and about 0.8 and 0.6 mm in diameter respectively. These standards, with similar shape and density as biopsy specimens were used to generate ARG calibration curves.Quantitative ARG was performed to measure the activitymore » concentration in biopsy specimens extracted from ten patients. The biopsy sites were determined according to PET/CT's obtained in the operating room. Additional CT scans were acquired with the needles in place to confirm correct needle placements. The ARG images were aligned with the needle tip in the PET/CT images using the open source CERR software. The mean SUV calculated from the specimen activities (SUVarg) were compared to that from PET (SUVpet) at the needle locations. Results: Calibration curves show that the relation between ARG signal and activity concentration in those standards is linear for the investigated range (up to 150 kBq/ml). The correlation coefficient of SUVarg with SUVpet is 0.74. Discrepancies between SUVarg and SUVpet can be attributed to the small size of the biopsy specimens compared to PET resolution. Conclusion: The calibration procedure using surrogate biopsy specimens provided a method for quantifying the activity within the biopsy cores obtained under FDG-PET guidance. QABS allows mapping the activity concentration in such biopsy specimens with a resolution of about 1mm. QABS is a promising tool for verification of biopsy adequacy by comparing specimen activity to that expected from the PET image. A portion of this research was funded by a research grant from Biospace Lab, 13 rue Georges Auric 75019 Paris, FRANCE.« less
Sutured clear corneal incision: wound apposition and permeability to bacterial-sized particles.
May, William N; Castro-Combs, Juan; Kashiwabuchi, Renata T; Tattiyakul, Woranart; Qureshi-Said, Saima; Hirai, Flavio; Behrens, Ashley
2013-03-01
To determine the effects of single radial or horizontal suture placement in 2-step clear corneal incision (CCI) wound apposition and permeability to particles of India ink. Five fresh human globes were included. Two 25-gauge needles connected to a saline solution bag and to a digital manometer were inserted through the limbus, 120 degrees apart from each other. Four 2-step CCIs (2.75 mm wide and 3 mm length) were constructed in each cornea. Incisions were divided into 3 groups: single radial suture (SRS), single horizontal suture (SHS), and unsutured group. Optical coherence tomography (OCT) was performed before and after suture placement. With a preset 10 mm Hg intraocular pressure (IOP), India ink was applied to the incision site and a standardized sudden IOP fluctuation was induced. OCT and superficial images were recorded before and after suture placement. India ink inflow and internal and external CCI gapping were outlined and measured by planimeter. The area and linear distance of India ink inflow after pressure challenge in all study groups were higher when compared with pre-pressure measurements; however, this increase was significant in the SRS and SHS groups (P < 0.05). Additionally, SRS placement significantly increased inner wound gapping (P = 0.018), and SHS significantly widened outer wound gape (P = 0.02). Well-constructed unsutured 2-step CCI seems to be more efficient at preventing bacterial-sized particles inflow during sudden changes in IOP, and it seems to offer better wound apposition as assessed by OCT.
Rombouts, Steffi J E; Nijkamp, Maarten W; van Dijck, Willemijn P M; Brosens, Lodewijk A A; Konings, Maurits; van Hillegersberg, R; Borel Rinkes, Inne H M; Hagendoorn, Jeroen; Wittkampf, Fred H; Molenaar, I Quintus
2017-01-01
Irreversible electroporation (IRE) with needle electrodes is being explored as treatment option in locally advanced pancreatic cancer. Several studies have shown promising results with IRE needles, positioned around the tumor to achieve tumor ablation. Disadvantages are the technical difficulties for needle placement, the time needed to achieve tumor ablation, the risk of needle track seeding and most important the possible occurrence of postoperative pancreatic fistula via the needle tracks. The aim of this experimental study was to evaluate the feasibility of a new IRE-technique using two parallel plate electrodes, in a porcine model. Twelve healthy pigs underwent laparotomy. The pancreas was mobilized to enable positioning of the paddles. A standard monophasic external cardiac defibrillator was used to perform an ablation in 3 separate parts of the pancreas; either a single application of 50 or 100J or a serial application of 4x50J. After 6 hours, pancreatectomy was performed for histology and pigs were terminated. Histology showed necrosis of pancreatic parenchyma with neutrophil influx in 5/12, 11/12 and 12/12 of the ablated areas at 50, 100, and 4x50J respectively. The electric current density threshold to achieve necrosis was 4.3, 5.1 and 3.4 A/cm2 respectively. The ablation threshold was significantly lower for the serial compared to the single applications (p = 0.003). The content of the ablated areas differed between the applications: areas treated with a single application of 50 J often contained vital areas without obvious necrosis, whereas half of the sections treated with 100 J showed small islands of normal looking cells surrounded by necrosis, while all sections receiving 4x 50 J showed a homogeneous necrotic lesion. Pancreatic tissue can be successfully ablated using two parallel paddles around the tissue. A serial application of 4x50J was most effective in creating a homogeneous necrotic lesion.
Smith, Brandon W; Joseph, Jacob R; Kirsch, Michael; Strasser, Mary Oakley; Smith, Jacob; Park, Paul
2017-08-01
OBJECTIVE Percutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy. METHODS Patients undergoing PPSI utilizing the K-wire-less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement. RESULTS Thirty-six patients (18 male and 18 female) were included. The patients' mean age was 60.4 years (range 23.8-78.4 years), and their mean body mass index was 28.5 kg/m 2 (range 20.8-40.1 kg/m 2 ). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4-14) were placed over a mean of 2.61 levels (range 1-7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort. CONCLUSIONS This streamlined 2-step K-wire-less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures. Images Fig. 3. PMID:758853
Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T
2018-04-17
Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.
Field evidence of strong differential pollen placement by Old World bat-pollinated plants
Stewart, Alyssa B.; Dudash, Michele R.
2017-01-01
Background and Aims Sympatric plant species that share pollinators potentially compete for pollination and risk interspecific pollen transfer, but this competition can be minimized when plant species place pollen on different areas of the pollinator’s body. Multiple studies have demonstrated strong differential pollen placement by sympatric plant species under laboratory conditions; however, field evidence collected in natural settings is less common. Furthermore, it is unknown whether precise pollen placement on the pollinator’s body remains constant throughout the foraging period, or if such patterns become diffused over time (e.g. due to grooming). To test the prevalence of differential pollen placement in the wild, we examined a community of five night-blooming plant species in southern Thailand that share common bat pollinators. Methods We mist-netted wild foraging nectar bats and collected pollen samples from four body parts: the crown of the head, face, chest and ventral side of one wing. We also noted the time of pollen collection to assess how pollinator pollen loads change throughout the foraging period. Key Results Our findings revealed that most of our plant study species placed pollen on precise areas of the bat, consistent with experimental work, and that patterns of differential pollen placement remained constant throughout the night. Conclusions This study demonstrates how diverse floral morphologies effectively limit interspecific pollen transfer among Old World bat-pollinated plants under natural conditions. Additionally, interspecific pollen transfer is probably minimal throughout the entire foraging period, since patterns of pollen on the bats’ bodies were consistent over time. PMID:27864223
Technique for CT Fluoroscopy-Guided Lumbar Medial Branch Blocks and Radiofrequency Ablation.
Amrhein, Timothy J; Joshi, Anand B; Kranz, Peter G
2016-09-01
The purpose of this study is to describe the procedure for CT fluoroscopy-guided lumbar medial branch blocks and facet radiofrequency ablation. CT fluoroscopic guidance allows more-precise needle tip positioning and is an alternative method for performing medial branch blocks and facet radiofrequency ablation.
The National Ignition Facility: alignment from construction to shot operations
NASA Astrophysics Data System (ADS)
Burkhart, S. C.; Bliss, E.; Di Nicola, P.; Kalantar, D.; Lowe-Webb, R.; McCarville, T.; Nelson, D.; Salmon, T.; Schindler, T.; Villanueva, J.; Wilhelmsen, K.
2010-08-01
The National Ignition Facility in Livermore, California, completed it's commissioning milestone on March 10, 2009 when it fired all 192 beams at a combined energy of 1.1 MJ at 351nm. Subsequently, a target shot series from August through December of 2009 culminated in scale ignition target design experiments up to 1.2 MJ in the National Ignition Campaign. Preparations are underway through the first half of of 2010 leading to DT ignition and gain experiments in the fall of 2010 into 2011. The top level requirement for beam pointing to target of 50μm rms is the culmination of 15 years of engineering design of a stable facility, commissioning of precision alignment, and precise shot operations controls. Key design documents which guided this project were published in the mid 1990's, driving systems designs. Precision Survey methods were used throughout construction, commissioning and operations for precision placement. Rigorous commissioning processes were used to ensure and validate placement and alignment throughout commissioning and in present day operations. Accurate and rapid system alignment during operations is accomplished by an impressive controls system to align and validate alignment readiness, assuring machine safety and productive experiments.
Hybrid reflection type metasurface of nano-antennas designed for optical needle field generation
NASA Astrophysics Data System (ADS)
Wang, Shiyi; Zhan, Qiwen
2015-03-01
We propose a reflection type metal-insulator-metal (MIM) metasurface composed of hybrid optical antennas for comprehensive spatial engineering the properties of optical fields. Its capability is illustrated with an example to create a radially polarized vectorial beam for optical needle field generation. Functioning as local quarter-wave-plates (QWP), the MIM metasurface is designed to convert circularly polarized incident into local linear polarization to create an overall radial polarization with corresponding binary phases and desired normalized amplitude modulation ranged from 0.07 to 1. To obtain enough degrees of freedom, the optical-antenna layer comprises periodic arrangements of double metallic nano-bars with perpendicular placement and single nano-bars respectively for different amplitude modulation requirements. Both of the antennas enable to introduce π/2 retardation while reaching the desired modulation range both for phase and amplitude. Through adjusting the antennas' geometry and array carefully, we shift the gap-surface plasmon resonances facilitated by optical antennas to realize the manipulation of vectorial properties. Designed at 1064 nm wavelength, the particularly generated vectorial light output can be further tightly focused by a high numerical aperture objective to obtain longitudinally polarized flat-top focal field. The so-called optical needle field is a promising candidate for novel applications that transcend disciplinary boundaries. The proposed metasurface establishes a new class of compact optical components based on nano-scale structures, leading to compound functions for vectorial light generation.
Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz
PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less
Lee, Chang-Hyung; Derby, Richard; Choi, Hyun-Seok; Lee, Sang-Heon; Kim, Se Hoon; Kang, Yoon Kyu
2010-01-01
One technique in radiofrequency neurotomies uses 2 electrodes that are simultaneously placed to lie parallel to one another. Comparing lesions on cadaveric interspinous ligament tissue and measuring the temperature change in egg white allows us to accurately measure quantitatively the area of the lesion. Fresh cadaver spinal tissue and egg white tissue were used. A series of samples were prepared with the electrodes placed 1 to 7 mm apart. Using radiofrequency, the needle electrodes were heated in sequential or simultaneous order and the distance of the escaped lesion area and temperature were measured. Samples of cadaver interspinous ligament showed sequential heating of the needles limits the placement of the needle electrodes up to 2 mm apart from each other and up to 4 mm apart when heated simultaneously. The temperature at the escaped lesion area decreased according to the distance for egg white. There was a significant difference in temperature at the escaped lesion area up to 6 mm apart and the temperature was above 50 degrees celsius up to 5 mm in simultaneous lesion and 3 mm in the sequential lesion. The limitations of this study include cadaveric experimentation and use of intraspinous ligament rather than medial branch of the dorsal ramus which is difficult to identify. Heating the 2 electrodes simultaneously appears to coagulate a wider area and potentially produce better results in less time.
Oliveira, Kauhanna Vianna de; Silva, Bruno Marques da; Leonardi, Denise Piotto; Crozeta, Bruno Monguilhott; Sousa-Neto, Manoel Damião de; Baratto-Filho, Flares; Gabardo, Marilisa Carneiro Leão
2017-12-18
The aim of this study was to compare two irrigation techniques and four devices for endodontic sealer placement into the dentinal tubules. Ninety-nine single-rooted human teeth were instrumented and allocated to either the control (CO) (n=11) or experimental groups according to the irrigation method: syringe and NaveTip needle (NT) (n=44), and EndoActivator (EA) (n=44). These groups were subdivided according to sealer placement into K-File (KF), lentulo spiral (LS), Easy Clean (EC), and EndoActivator (EA) subgroups. Moreover, the distances of 5 mm and 2 mm from the apex were analyzed. The teeth were obturated with AH Plus and GuttaCore X3. Analyses were performed by scanning electron microscopy associated to cathodoluminescence. The percentage and maximum depth of sealer penetration were measured. Data were evaluated by three-way analysis of variance (ANOVA) and Games-Howell test (p<0.05). EA was superior to NT in percentage of sealer penetration. EC was significantly superior to EA (subgroup) for sealer penetration, and both improved the percentage of sealer penetration when compared to LS. Better sealer penetration was observed at the distance of 5 mm from the apex. Sealer penetration into the dentinal tubules was significantly improved by sonic irrigant activation.
Planar super-oscillatory lens for sub-diffraction optical needles at violet wavelengths
Yuan, Guanghui; Rogers, Edward T. F.; Roy, Tapashree; Adamo, Giorgio; Shen, Zexiang; Zheludev, Nikolay I.
2014-01-01
Planar optical lenses are fundamental elements of miniaturized photonic devices. However, conventional planar optical lenses are constrained by the diffraction limit in the optical far-field due to the band-limited wavevectors supported by free-space and loss of high-spatial-frequency evanescent components. As inspired by Einstein's radiation ‘needle stick', electromagnetic energy can be delivered into an arbitrarily small solid angle. Such sub-diffraction optical needles have been numerically investigated using diffractive optical elements (DOEs) together with specially polarized optical beams, but experimental demonstration is extremely difficult due to the bulky size of DOEs and the required alignment precision. Planar super-oscillatory lenses (SOLs) were proposed to overcome these constraints and demonstrated that sub-diffraction focal spots can actually be formed without any evanescent waves, making far-field, label-free super-resolution imaging possible. Here we extend the super-oscillation concept into the vectorial-field regime to work with circularly polarized light, and experimentally demonstrate, for the first time, a circularly polarized optical needle with sub-diffraction transverse spot size (0.45λ) and axial long depth of focus (DOF) of 15λ using a planar SOL at a violet wavelength of 405 nm. This sub-diffraction circularly polarized optical needle has potential applications in circular dichroism spectroscopy, super-resolution imaging, high-density optical storage, heat-assisted magnetic recording, nano-manufacturing and nano-metrology. PMID:25208611
Mohta, Medha; Agarwal, Deepti; Sethi, AK
2011-01-01
Needle-through-needle combined spinal–epidural (CSE) may cause significant delay in patient positioning resulting in settling down of spinal anaesthetic and unacceptably low block level. Bilateral hip flexion has been shown to extend the spinal block by flattening lumbar lordosis. However, patients with lower limb fractures cannot flex their injured limb. This study was conducted to find out if unilateral hip flexion could extend the level of spinal anaesthesia following a prolonged CSE technique. Fifty American Society of Anesthesiologists (ASA) I/II males with unilateral femur fracture were randomly allocated to Control or Flexion groups. Needle-through-needle CSE was performed in the sitting position at L2-3 interspace and 2.6 ml 0.5% hyperbaric bupivacaine injected intrathecally. Patients were made supine 4 min after the spinal injection or later if epidural placement took longer. The Control group patients (n=25) lay supine with legs straight, whereas the Flexion group patients (n=25) had their uninjured hip and knee flexed for 5 min. Levels of sensory and motor blocks and time to epidural drug requirement were recorded. There was no significant difference in sensory levels at different time-points; maximum sensory and motor blocks; times to achieve maximum blocks; and time to epidural drug requirement in two groups. However, four patients in the Control group in contrast to none in the Flexion group required epidural drug before start of surgery. Moreover, in the Control group four patients took longer than 30 min to achieve maximum sensory block. To conclude, unilateral hip flexion did not extend the spinal anaesthetic level; however, further studies are required to explore the potential benefits of this technique. PMID:21808396
Usability evaluation of intradermal adapters (IDA).
Tsals, Izrail
2017-03-27
Intradermal adapter device technology minimizes the complexity of the Mantoux technique, thereby providing predictable, reproducible intradermal (ID) injections and removing the concerns regarding the ease and reliability of Mantoux technique when using conventional needle and syringe. The technology employs a simple device with geometry designed to gently deform the skin surface and the subcutaneous tissue, providing the ideal angle and depth of needle insertion for consistently successful intradermal injections. The results of this development were presented at the First, Second and Third Skin Vaccination Summits in 2011, 2013 and 2015 respectively [1,2,3]. The current publication addresses the performance of intradermal adapters (IDA) evaluated in three preclinical studies. The evaluations were based on the assessment of bleb formation in a skin model, an accepted indicator of ID injection success. All evaluated devices share the same proprietary dermal interface technology. Devices instituting this design are easy to use, require minimal training, and employ conventionally molded parts and cannula. These studies evaluated IDAs of initial design integral with luer lock needles, IDAs for use with conventional syringes, and intradermal adapters for use with auto disable syringes (ADID adapters). The evaluated ID adapters were intended to consistently place the lancet of the needle at a depth of 0.75mm from the skin's surface. This placement depth addresses the variation in the skin thickness at immunization sites for the majority of patients independent of many other variables. Most participants preferred the intradermal adapter method over the traditional Mantoux and identified a need for the adapter at their workplace. Evaluation of IDAs by registered nurses indicated these devices increase success of bleb formation. The use of IDA increased the success of forming blebs by about 30%. Nurses felt the injections were much easier to perform, in particular by novices. Copyright © 2016 Elsevier Ltd. All rights reserved.
The effect of second-stage pushing and body mass index on postdural puncture headache.
Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S
2017-02-01
To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese <30, obese 30-39.99, morbidly obese 40-49.99, and super obese ≥50. Headache, number of days of headache, maximum headache score, and epidural blood patch placement. Compared with women who did not push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; P<.01). In a multivariate logistic regression model, lack of pushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.
Salazar, Gloria; Yeddula, Kalpana; Wicky, Stephan; Oklu, Ramhi; Ganguli, Suvranu; Waltman, Arthur C; Walker, Thomas G; Kalva, Sanjeeva P
2013-01-01
To compare complication rates in patients who have port-a-catheters inserted and left accessed for immediate use and those who have ports inserted but not accessed. In this retrospective, IRB-approved study, medical records of patients who received a port catheter between 9/2009 and 2/2010 were reviewed. The data collected included patient demographics, diagnosis, procedure and complications. The patients were categorized into two groups: accessed (patients in whom the port was accessed with a Huber needle for immediate intravenous use and the patient left the procedure area with needle indwelling) and control (patients in whom the ports were not accessed). Complications were classified according to Society of Interventional Radiology guidelines. Results are given as mean ±SD. Statistical analysis was performed with student t test and statistical significance was considered at P<.05. A total of 467 ports were placed in 465 patients (Men: 206); 10.7% in the accessed group (n=50, age: 60±13.9) and 89.3% in the control group (n=417, age: 59±13.5). There were no statistically significant differences in patient demographics between the groups. The overall complication rate was 0.6% (n=3). Two complications (hematoma causing skin necrosis and thrombosis of the port) occurred in the control group and one (infection) in the accessed group. Infection rates after procedures were 2% (1/50) in the accessed group and 0% (0/417) in the control group. There was no statistically significant difference in overall complication (P=.1) and infection (P=.1) rates among the groups. Leaving the port accessed immediately after placement does not increase the risk of infection or other complications.
Fast MRI-guided vacuum-assisted breast biopsy: initial experience.
Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K
2003-11-01
The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.
Salkin, J A; Stuchin, S A; Kummer, F J; Reininger, R
1995-11-01
Five types of commercial glove liners (within double latex gloves) were compared to single and double latex gloves for cut and puncture resistance and for relative manual dexterity and degree of sensibility. An apparatus was constructed to test glove-pseudofinger constructs in either a cutting or puncture mode. Cutting forces, cutting speed, and type of blade (serrated or scalpel blade) were varied and the time to cut-through measured by an electrical conductivity circuit. Penetration forces were similarly determined with a scalpel blade and a suture needle using a spring scale loading apparatus. Dexterity was measured with an object placement task among a group of orthopedic surgeons. Sensibility was assessed with Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry using standard techniques and rating scales. A subjective evaluation was performed at the end of testing. Time to cut-through for the liners ranged from 2 to 30 seconds for a rapid oscillating scalpel and 4 to 40 seconds for a rapid oscillating serrated knife under minimal loads. When a 1 kg load was added, times to cut-through ranged from 0.4 to 1.0 second. In most cases, the liners were superior to double latex. On average, 100% more force was required to penetrate the liners with a scalpel and 50% more force was required to penetrate the liners with a suture needle compared to double latex. Object placement task times were not significantly liners compared to double latex gloves. Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry showed no difference in sensibility among the various liners and double latex gloves. Subjects felt that the liners were minimally to moderately impairing. An acclimation period may be required for their effective use.
The Importance of Biopsy in the Era of Molecular Medicine.
Ziv, Etay; Durack, Jeremy C; Solomon, Stephen B
Recent advances in the molecular characterization of cancers have triggered interest in developing a new taxonomy of disease in oncology with the goal of using the molecular profile of a patient's tumor to predict response to treatment. Image-guided needle biopsy is central to this "precision medicine" effort. In this review, we first discuss the current role of biopsy in relation to clinical examples of molecular medicine. We then outline important bottlenecks to the advancement of precision medicine and highlight the potential role of image-guided biopsy to address these challenges.
Use of a lumen-apposing metal stent to treat GI strictures (with videos).
Irani, Shayan; Jalaj, Sujai; Ross, Andrew; Larsen, Michael; Grimm, Ian S; Baron, Todd H
2017-06-01
Benign GI strictures occur typically in the esophagus and pyloric channel but can occur anywhere in the GI tract and at anastomotic sites. Such strictures can be treated with dilation, incisional therapy, steroid injection, and stents. Our aim was to describe the use of a lumen-apposing metal stent (LAMS) to treat short, benign GI strictures. Consecutive patients who underwent LAMS placement for various benign strictures at 2 tertiary care centers from August 2014 to November 2015 were reviewed retrospectively. The main outcome measures were technical success, clinical success, stent migration, and adverse events. Twenty-five patients (7 males, 18 females) with a median age of 54 years (33-85 years) underwent 28 LAMS placements to treat various benign strictures. The location of the strictures included esophagogastric anastomoses (n=4), gastrojejunal anastomoses (n=13), pylorus (n=6), vertical banded gastroplasty (n=1), and ileocolonic anastomosis (n=1). Twenty patients had been previously treated with dilation alone (9 patients with ≥3 dilations), 11 patients with dilation and steroid injection, 2 patients with additional needle-knife therapy, and 1 patient with placement of a traditional fully covered self-expandable metal stent. A 15-mm internal diameter LAMS was placed in all patients; 3 patients had been treated previously with a 10-mm LAMS. Technical success was achieved in all patients, whereas clinical success was achieved in 15 of 25 patients (60%) who completed a minimum of 6 months of follow-up after placement. Median stent dwell time was 92 days (range, 3-273 days). Stent migration was seen in 2 of 28 stent placements (7%). Four of 25 patients (16%) developed 5 moderate adverse events (pain requiring removal, 2; new stricture formation, 2; bleeding, 1). Median follow-up was 301 days after stent placement. Study limitations include the small, select group of patients, the retrospective study design, and short follow-up. LAMS placement for benign GI strictures is technically easy and safe with low migration rates and may be an option to treat selected patients with short-length strictures. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Li, Xu; Zhang, Feng; Zhang, Wenzhi; Shang, Xifu; Han, Jintao; Liu, Pengfei
2017-03-01
Technique note. To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. IV.
Noncontact viscoelastic measurement of polymer thin films in a liquid medium using a long-needle AFM
NASA Astrophysics Data System (ADS)
Guan, Dongshi; Barraud, Chloe; Charlaix, Elisabeth; Tong, Penger
We report noncontact measurement of the viscoelastic property of polymer thin films in a liquid medium using frequency-modulation atomic force microscopy (FM-AFM) with a newly developed long-needle probe. The probe contains a long vertical glass fiber with one end adhered to a cantilever beam and the other end with a sharp tip placed near the liquid-film interface. The nanoscale flow generated by the resonant oscillation of the needle tip provides a precise hydrodynamic force acting on the soft surface of the thin film. By accurately measuring the mechanical response of the thin film, we obtain the elastic and loss moduli of the thin film using the linear response theory of elasto-hydrodynamics. The experiment verifies the theory and demonstrates its applications. The technique can be used to accurately measure the viscoelastic property of soft surfaces, such as those made of polymers, nano-bubbles, live cells and tissues. This work was supported by the Research Grants Council of Hong Kong SAR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn; Su Lixin, E-mail: sulixin1975@126.com
2013-02-15
ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Controlmore » angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.
PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less
3D sensor placement strategy using the full-range pheromone ant colony system
NASA Astrophysics Data System (ADS)
Shuo, Feng; Jingqing, Jia
2016-07-01
An optimized sensor placement strategy will be extremely beneficial to ensure the safety and cost reduction considerations of structural health monitoring (SHM) systems. The sensors must be placed such that important dynamic information is obtained and the number of sensors is minimized. The practice is to select individual sensor directions by several 1D sensor methods and the triaxial sensors are placed in these directions for monitoring. However, this may lead to non-optimal placement of many triaxial sensors. In this paper, a new method, called FRPACS, is proposed based on the ant colony system (ACS) to solve the optimal placement of triaxial sensors. The triaxial sensors are placed as single units in an optimal fashion. And then the new method is compared with other algorithms using Dalian North Bridge. The computational precision and iteration efficiency of the FRPACS has been greatly improved compared with the original ACS and EFI method.
Field evidence of strong differential pollen placement by Old World bat-pollinated plants.
Stewart, Alyssa B; Dudash, Michele R
2017-01-01
Sympatric plant species that share pollinators potentially compete for pollination and risk interspecific pollen transfer, but this competition can be minimized when plant species place pollen on different areas of the pollinator's body. Multiple studies have demonstrated strong differential pollen placement by sympatric plant species under laboratory conditions; however, field evidence collected in natural settings is less common. Furthermore, it is unknown whether precise pollen placement on the pollinator's body remains constant throughout the foraging period, or if such patterns become diffused over time (e.g. due to grooming). To test the prevalence of differential pollen placement in the wild, we examined a community of five night-blooming plant species in southern Thailand that share common bat pollinators. We mist-netted wild foraging nectar bats and collected pollen samples from four body parts: the crown of the head, face, chest and ventral side of one wing. We also noted the time of pollen collection to assess how pollinator pollen loads change throughout the foraging period. Our findings revealed that most of our plant study species placed pollen on precise areas of the bat, consistent with experimental work, and that patterns of differential pollen placement remained constant throughout the night. This study demonstrates how diverse floral morphologies effectively limit interspecific pollen transfer among Old World bat-pollinated plants under natural conditions. Additionally, interspecific pollen transfer is probably minimal throughout the entire foraging period, since patterns of pollen on the bats' bodies were consistent over time. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Rodrigues, Pedro L.; Moreira, António H. J.; Rodrigues, Nuno F.; Pinho, A. C. M.; Fonseca, Jaime C.; Lima, Estevão.; Vilaça, João. L.
2014-03-01
Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.
The Missed Inferior Alveolar Block: A New Look at an Old Problem
Milles, Maano
1984-01-01
A variation of a previously described technique to obtain mandibular block anesthesia is presented. This technique varies from those previously described in that is uses palpable anatomic landmarks, both extra- and intraoral, to orient the placement of the needle. This technique relies on several readily observed landmarks and the integration of these landmarks. Because palpable landmarks are used, consistent results can be easily obtained even in patients who present with a wide variety of anatomical variances which otherwise make this injection technique difficult and prone to failure. ImagesFigure 1Figure 3Figure 4Figure 5Figure 6 PMID:6597690
Highly controlled vascular syringes for pericardiocentesis.
Ricciardi, Mark; Roldan, Carlos; Sibbitt, Randy; Sibbitt, Wilmer; Michael, Adrian; Palmer, Dennis
2010-12-01
The present study determined the utility and needle control characteristics of highly controlled vascular syringes for image-guided pericardiocentesis. Vascular syringes have been integrated into invasive cardiovascular procedures with improved patient safety, but to date have not been used in pericardiocentesis. To address this issue, we determined the method of use of vascular syringes for pericardiocentesis. A vascular syringe with reciprocating plungers, the reciprocating procedure device (RPD syringe), replaced the corresponding 10 ml and 20 ml conventional syringes in a standard pericardiocentesis tray. The vascular syringe is controlled with one hand, and can either aspirate or inject by pushing the corresponding aspiration or injection plunger. Four hundred and thirty seven subjects underwent vascular syringe procedures. The linear displacement method was used to precisely measure control of the needle tip in millimeters (mm) in vascular syringes compared to conventional syringes in 20 individual operators. Relative to the corresponding 10 ml and 20 ml conventional syringes, vascular syringes significantly reduced unintended forward penetration of the needle tip by 44% (7.0 ± 4.3 mm; p < 0.0001) and 53% (10.1 ± 5.5 mm; p < 0.0001), respectively, and reduced unintended retraction of the needle by 56% (2.7 ± 2.2 mm; p < 0.001) and 60% (3.5 ± 2.5 mm; p < 0.001), respectively. During pericardiocentesis, the mechanical syringe permitted facile one-handed aspiration and maintained the operator's ability to clear the needle. In the 437 vascular syringe procedures, there were no complications, with an estimated cost savings of $10-65 per procedure. Vascular syringes improve needle control in pericardiocentesis, promote patient safety and permit one-handed aspiration and injection.
Using image analysis for quantitative assessment of needle bladder rust disease of Norway spruce.
Ganthaler, A; Losso, A; Mayr, S
2018-06-01
High elevation spruce forests of the European Alps are frequently infected by the needle rust Chrysomyxa rhododendri , a pathogen causing remarkable defoliation, reduced tree growth and limited rejuvenation. Exact quantification of the disease severity on different spatial scales is crucial for monitoring, management and resistance breeding activities. Based on the distinct yellow discolouration of attacked needles, it was investigated whether image analysis of digital photographs can be used to quantify disease severity and to improve phenotyping compared to conventional assessment in terms of time, effort and application range. The developed protocol for preprocessing and analysis of digital RGB images enabled identification of disease symptoms and healthy needle areas on images obtained in ground surveys (total number of analysed images n = 62) and by the use of a semiprofessional quadcopter ( n = 13). Obtained disease severities correlated linearly with results obtained by manual counting of healthy and diseased needles for all approaches, including images of individual branches with natural background ( R 2 = 0.87) and with black background ( R 2 = 0.95), juvenile plants ( R 2 = 0.94), and top views and side views of entire tree crowns of adult trees ( R 2 = 0.98 and 0.88, respectively). Results underline that a well-defined signal related to needle bladder rust symptoms of Norway spruce can be extracted from images recorded by standard digital cameras and using drones. The presented protocol enables precise and time-efficient quantification of disease symptoms caused by C. rhododendri and provides several advantages compared to conventional assessment by manual counting or visual estimations.
Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2015-06-01
This work presents a new steerable needle to facilitate active steering toward predefined target locations. It focuses on mechanical aspects and design choices in relation to the observed response in a tissue phantom. Tip steering with two rotational degrees of freedom was achieved by a tendon actuated ball joint mechanism. During insertion, the flexible cannula bends as a result of asymmetric tip-tissue interaction forces. The stylet was equipped with fiber Bragg gratings to measure the needle shape and tip position during use. A PI-controller was implemented to facilitate steering to predefined targets. During the validation study, nine targets were defined at a depth of 100 mm below the gelatin surface. One was located below the insertion point, the others at a radial offset of 30 mm in each of the eight principle steering directions. Per location, six repetitions were performed. The targeting accuracy was 6.2 ± 1.4 mm (mean ± std). The steering precision was 2.6 ± 1.1 mm. The ability to steer with this new needle steering approach is presented and the mechanical characteristics are discussed for this representative subset of steering directions. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Moche, Michael; Zajonz, Dirk; Kahn, Thomas; Busse, Harald
2010-04-01
To present the clinical setup and workflow of a robotic assistance system for image-guided interventions in a conventional magnetic resonance imaging (MRI) environment and to report our preliminary clinical experience with percutaneous biopsies in various body regions. The MR-compatible, servo-pneumatically driven, robotic device (Innomotion) fits into the 60-cm bore of a standard MR scanner. The needle placement (n = 25) accuracy was estimated by measuring the 3D deviation between needle tip and prescribed target point in a phantom. Percutaneous biopsies in six patients and different body regions were planned by graphically selecting entry and target points on intraoperatively acquired roadmap MR data. For insertion depths between 29 and 95 mm, the average 3D needle deviation was 2.2 +/- 0.7 mm (range 0.9-3.8 mm). Patients with a body mass index of up to approximately 30 kg/m(2) fitted into the bore with the device. Clinical work steps and limitations are reported for the various applications. All biopsies were diagnostic and could be completed without any major complications. Median planning and intervention times were 25 (range 20-36) and 44 (36-68) minutes, respectively. Preliminary clinical results in a standard MRI environment suggest that the presented robotic device provides accurate guidance for percutaneous procedures in various body regions. Shorter procedure times may be achievable by optimizing technical and workflow aspects. (c) 2010 Wiley-Liss, Inc.
Patel, Priya; Wada, Hironobu; Hu, Hsin-Pei; Hirohashi, Kentaro; Kato, Tatsuya; Ujiie, Hideki; Ahn, Jin Young; Lee, Daiyoon; Geddie, William; Yasufuku, Kazuhiro
2017-04-01
Endobronchial ultrasonography (EBUS)-guided transbronchial needle aspiration allows for sampling of mediastinal lymph nodes. The external diameter, rigidity, and angulation of the convex probe EBUS renders limited accessibility. This study compares the accessibility and transbronchial needle aspiration capability of the prototype thin convex probe EBUS against the convex probe EBUS in human ex vivo lungs rejected for transplant. The prototype thin convex probe EBUS (BF-Y0055; Olympus, Tokyo, Japan) with a thinner tip (5.9 mm), greater upward angle (170 degrees), and decreased forward oblique direction of view (20 degrees) was compared with the current convex probe EBUS (6.9-mm tip, 120 degrees, and 35 degrees, respectively). Accessibility and transbronchial needle aspiration capability was assessed in ex vivo human lungs declined for lung transplant. The distance of maximum reach and sustainable endoscopic limit were measured. Transbronchial needle aspiration capability was assessed using the prototype 25G aspiration needle in segmental lymph nodes. In all evaluated lungs (n = 5), the thin convex probe EBUS demonstrated greater reach and a higher success rate, averaging 22.1 mm greater maximum reach and 10.3 mm further endoscopic visibility range than convex probe EBUS, and could assess selectively almost all segmental bronchi (98% right, 91% left), demonstrating nearly twice the accessibility as the convex probe EBUS (48% right, 47% left). The prototype successfully enabled cytologic assessment of subsegmental lymph nodes with adequate quality using the dedicated 25G aspiration needle. Thin convex probe EBUS has greater accessibility to peripheral airways in human lungs and is capable of sampling segmental lymph nodes using the aspiration needle. That will allow for more precise assessment of N1 nodes and, possibly, intrapulmonary lesions normally inaccessible to the conventional convex probe EBUS. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.
Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U
2014-01-01
This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.
Sergent, F; Gay-Crosier, G; Resch, B; Pons, J-C; Marpeau, L
2014-03-01
To evaluate complications and functional outcomes at 1 year and more of a modified Tension-free Vaginal Tape (TVT) technique from that of classic TVT. Retrospective study comparing the two techniques. For the modified TVT technique, a peri-urethrovesical hydrodissection was performed. An 18-gauge hollow needle, in which a thread was introduced, was used as an ancillary for the placement of the sling. The sling was secured to the thread and then positioned with it. Bladder filling objectified perforations. An absorbable suture around the sling allowed its descent if necessary. One hundred and eighteen procedures were performed (54 classic TVT and 64 modified TVT). For the standard TVT and the modified TVT, the vesico-urethral perforation rates were respectively 7.4% and 1.5% (P<0.05), those of reoperations for pulling the sling downward 11.1% and 1.5% (P<0.05). A 1 year and more, healing and satisfaction rates were respectively 83.3% and 79.2% for the standard TVT versus 88.2% and 90% for the modified TVT (NS). The dissatisfaction rate was lower for the modified TVT (P<0.05). By modifying the placement of the classic TVT, it is possible to reduce its complications while maintaining its efficacy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N
2011-01-01
Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.
Wiener, Renda Soylemez; Schwartz, Lisa M; Woloshin, Steven; Welch, H Gilbert
2011-08-02
Because pulmonary nodules are found in up to 25% of patients undergoing computed tomography of the chest, the question of whether to perform biopsy is becoming increasingly common. Data on complications after transthoracic needle lung biopsy are limited to case series from selected institutions. To determine population-based estimates of risks for complications after transthoracic needle biopsy of a pulmonary nodule. Cross-sectional analysis. The 2006 State Ambulatory Surgery Databases and State Inpatient Databases for California, Florida, Michigan, and New York from the Healthcare Cost and Utilization Project. 15 865 adults who had transthoracic needle biopsy of a pulmonary nodule. Percentage of biopsies complicated by hemorrhage, any pneumothorax, or pneumothorax requiring a chest tube, and adjusted odds ratios for these complications associated with various biopsy characteristics, calculated by using multivariate, population-averaged generalized estimating equations. Although hemorrhage was rare, complicating 1.0% (95% CI, 0.9% to 1.2%) of biopsies, 17.8% (CI, 11.8% to 23.8%) of patients with hemorrhage required a blood transfusion. In contrast, the risk for any pneumothorax was 15.0% (CI, 14.0% to 16.0%), and 6.6% (CI, 6.0% to 7.2%) of all biopsies resulted in pneumothorax requiring a chest tube. Compared with patients without complications, those who experienced hemorrhage or pneumothorax requiring a chest tube had longer lengths of stay (P < 0.001) and were more likely to develop respiratory failure requiring mechanical ventilation (P = 0.020). Patients aged 60 to 69 years (as opposed to younger or older patients), smokers, and those with chronic obstructive pulmonary disease had higher risk for complications. Estimated risks may be inaccurate if coding of complications is incomplete. The analyzed databases contain little clinical detail (such as information on nodule characteristics or biopsy pathology) and cannot indicate whether performing the biopsy produced useful information. Whereas hemorrhage is an infrequent complication of transthoracic needle lung biopsy, pneumothorax is common and often necessitates chest tube placement. These population-based data should help patients and physicians make more informed choices about whether to perform biopsy of a pulmonary nodule. Department of Veterans Affairs and National Cancer Institute.
Wiener, Renda Soylemez; Schwartz, Lisa M.; Woloshin, Steven; Welch, H. Gilbert
2011-01-01
Background Because pulmonary nodules are found in up to 25% of patients undergoing chest computed tomography, the question of whether to biopsy is becoming increasingly common. Data on complications following transthoracic needle lung biopsy are limited to case series from selected institutions. Objective To determine population-based estimates of risks of complications following transthoracic needle biopsy of a pulmonary nodule. Design Cross-sectional analysis. Setting The 2006 Healthcare Cost and Utilization Project’s State Ambulatory Surgery Databases and State Inpatient Databases for California, Florida, Michigan, and New York. Patients 15,865 adults who underwent transthoracic needle biopsy of a pulmonary nodule. Measurements Percent of biopsies complicated by hemorrhage, any pneumothorax, and pneumothorax requiring chest tube, and adjusted odds ratios for these complications associated with various biopsy characteristics, calculated using multivariable population-averaged generalized estimating equations. Results Although hemorrhage was rare, complicating 1.0% (95% CI 0.9-1.2%) of biopsies, 17.8% (95% CI 11.8-23.8%) of patients with hemorrhage required a blood transfusion. By contrast, the risk of any pneumothorax was 15.0% (95% CI 14.0-16.0%), and 6.6% (95% CI 6.0-7.2%) of all biopsies resulted in a pneumothorax requiring chest tube. Compared to patients without complications, those who experienced hemorrhage or pneumothorax requiring chest tube had longer lengths of stay (p<0.001) and were more likely to develop respiratory failure requiring mechanical ventilation (p=0.02). Patients aged 60-69 years (as opposed to younger or older patients), smokers, and those with chronic obstructive pulmonary disease had higher risk of complications. Limitations Estimated risks may be inaccurate if coding of complications is incomplete. The databases analyzed contain little clinical detail (e.g., nodule characteristics, biopsy pathology) and cannot determine whether biopsies produced useful information. Conclusion While hemorrhage is an infrequent complication of transthoracic needle lung biopsy, pneumothorax is common and often necessitates chest tube placement. These population-based data should help patients and doctors make a more informed choice on whether to biopsy a pulmonary nodule. Primary Funding Source Department of Veterans Affairs and National Cancer Institute K07 CA 138772 PMID:21810706
[Gas tamponade following intraoperative pneumothorax on a single lung: A case study].
El Jaouhari, S D; Mamane Nassirou, O; Meziane, M; Bensghir, M; Haimeur, C
2017-04-01
Intraoperative pneumothorax is a rare complication with a high risk of cardiorespiratory arrest by gas tamponade especially on a single lung. We report the case of a female patient aged 53 years who benefited from a left pneumonectomy on pulmonary tuberculosis sequelae. The patient presented early postoperative anemia with a left hemothorax requiring an emergency thoracotomy. In perioperative, the patient had a gas tamponade following a pneumothorax of the remaining lung, and the fate has been avoided by an exsufflation. Intraoperative pneumothorax can occur due to lesions of the tracheobronchial airway, of the brachial plexus, the placement of a central venous catheter or barotrauma. The diagnosis of pneumothorax during unipulmonary ventilation is posed by the sudden onset of hypoxia associated with increased airway pressures and hypercapnia. The immediate life-saving procedure involves fine needle exsufflation before the placement of a chest tube. Prevention involves reducing the risk of barotrauma by infusing patients with low flow volumes and the proper use of positive airway pressure, knowing that despite protective ventilation, barotraumas risk still exists. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
T-tube drainage of the common bile duct choleperitoneum: etiology and management.
Daldoul, S; Moussi, A; Zaouche, A
2012-06-01
External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Munyon, Charles N; Koubeissi, Mohamad Z; Syed, Tanvir U; Lüders, Hans O; Miller, Jonathan P
2013-01-01
Frame-based stereotaxy and open craniotomy may seem mutually exclusive, but invasive electrophysiological monitoring can require broad sampling of the cortex and precise targeting of deeper structures. The purpose of this study is to describe simultaneous frame-based insertion of depth electrodes and craniotomy for placement of subdural grids through a single surgical field and to determine the accuracy of depth electrodes placed using this technique. A total of 6 patients with intractable epilepsy underwent placement of a stereotactic frame with the center of the planned cranial flap equidistant from the fixation posts. After volumetric imaging, craniotomy for placement of subdural grids was performed. Depth electrodes were placed using frame-based stereotaxy. Postoperative CT determined the accuracy of electrode placement. A total of 31 depth electrodes were placed. Mean distance of distal electrode contact from the target was 1.0 ± 0.15 mm. Error was correlated to distance to target, with an additional 0.35 mm error for each centimeter (r = 0.635, p < 0.001); when corrected, there was no difference in accuracy based on target structure or method of placement (prior to craniotomy vs. through grid, p = 0.23). The described technique for craniotomy through a stereotactic frame allows placement of subdural grids and depth electrodes without sacrificing the accuracy of a frame or requiring staged procedures.
Finelle, Gary; Lee, Sang J
Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.
Design of a low cost spinneret assembly for coaxial electrospinning
NASA Astrophysics Data System (ADS)
Raheja, Anant; Chandra, T. S.; Natarajan, T. S.
2015-06-01
Coaxial electrospinning makes use of a concentric arrangement of spinneret orifices for synthesis of core-shell polymer nanofibers. Most laboratories purchase the spinneret from commercial manufacturers at a significant expense, or design it indigenously to save costs but compromise on manufacturing precision. Therefore, the present work suggests the use of a relatively lower priced McIntyre cannula needle, conventionally used for ophthalmic surgeries, as a coaxial spinneret for electrospinning. The McIntyre cannula needle was modified to synthesize hollow fibers of nylon 6, which acted as sheath with hydrogen peroxide as core during electrospinning. In addition, encapsulation of bioactives, viz., red blood cells, bacterial cells, and lysozyme (enzyme protein) was attempted, using their aqueous suspensions as core, with polycaprolactone solution as sheath. Resulting fibers had an integral core-shell structure with the bioactives encapsulated in the core. This indicated that the modified McIntyre cannula functions suitably as a spinneret for coaxial electrospinning. Thus, apart from being a clinical device, the modified McIntyre cannula needle provides an economic alternative to conventional coaxial spinneret assemblies.
NASA Astrophysics Data System (ADS)
Wu, Hao; Yu, Jun; Cao, Rui; Yang, Yinghua; Tang, Zhenan
2018-05-01
A high-performance low-power micro hotplate (MHP) hydrogen sensor was fabricated through electrohydrodynamic (EHD) inkjet printing technique. Electrospun Pd loaded SnO2 nanofibers with lengths of 250-850 nm were precisely printed on the suspended central part of an MHP with an area of 100 um × 100 um. The printhead in the printing system was a low-cost metallic needle with an inner diameter of 110 um, which was large enough to prevent clogging by the nanofibers. The printing process was observed by a high-speed camera. Small droplets with diameters of 50-80 um were produced at each ejection by providing a high voltage to the metallic needle. It was found that the bridge-type MHPs used in our experiment can promote the positioning precision due to its bound effect to the droplet. In the gas sensing measurement, the Pd loaded SnO2 MHP gas sensor showed a remarkable response to H2 with a low power of only 9.1 mW. The experiment results demonstrate the excellent adequacy of EHD inkjet printing technique to realize effective mass fabrication of MHP gas sensors or sensor arrays.
Yang, Yunpeng; Jiang, Shan; Yang, Zhiyong; Yuan, Wei; Dou, Huaisu; Wang, Wei; Zhang, Daguang; Bian, Yuan
2017-04-01
Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography-compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography-compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.
Frisenda, Riccardo; Navarro-Moratalla, Efrén; Gant, Patricia; Pérez De Lara, David; Jarillo-Herrero, Pablo; Gorbachev, Roman V; Castellanos-Gomez, Andres
2018-01-02
Designer heterostructures can now be assembled layer-by-layer with unmatched precision thanks to the recently developed deterministic placement methods to transfer two-dimensional (2D) materials. This possibility constitutes the birth of a very active research field on the so-called van der Waals heterostructures. Moreover, these deterministic placement methods also open the door to fabricate complex devices, which would be otherwise very difficult to achieve by conventional bottom-up nanofabrication approaches, and to fabricate fully-encapsulated devices with exquisite electronic properties. The integration of 2D materials with existing technologies such as photonic and superconducting waveguides and fiber optics is another exciting possibility. Here, we review the state-of-the-art of the deterministic placement methods, describing and comparing the different alternative methods available in the literature, and we illustrate their potential to fabricate van der Waals heterostructures, to integrate 2D materials into complex devices and to fabricate artificial bilayer structures where the layers present a user-defined rotational twisting angle.
Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald
2007-04-01
This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.
ERIC Educational Resources Information Center
Dwight, Ernest
2008-01-01
Campus signage provides important navigational information, and it reflects an institution's image. Creating a signage system using strategically planned design methodology, precision fabrication, plus well-planned placement, enhances a campus environment. This helps create a positive experience for visitors and prospective students. An effective…
Single-cell-precision microplasma-induced cancer cell apoptosis.
Tan, Xiao; Zhao, Shasha; Lei, Qian; Lu, Xinpei; He, Guangyuan; Ostrikov, Kostya
2014-01-01
The issue of single-cell control has recently attracted enormous interest. However, in spite of the presently achievable intracellular-level physiological probing through bio-photonics, nano-probe-based, and some other techniques, the issue of inducing selective, single-cell-precision apoptosis, without affecting neighbouring cells remains essentially open. Here we resolve this issue and report on the effective single-cell-precision cancer cell treatment using the reactive chemistry of the localized corona-type plasma discharge around a needle-like electrode with the spot size ∼1 µm. When the electrode is positioned with the micrometer precision against a selected cell, a focused and highly-localized micro-plasma discharge induces apoptosis in the selected individual HepG2 and HeLa cancer cells only, without affecting any surrounding cells, even in small cell clusters. This is confirmed by the real-time monitoring of the morphological and structural changes at the cellular and cell nucleus levels after the plasma exposure.
Portable Optical Epidural Needle-A CMOS-Based System Solution and Its Circuit Design
Gong, Cihun-Siyong Alex; Lin, Shih-Pin; Mandell, M. Susan; Tsou, Mei-Yung; Chang, Yin; Ting, Chien-Kun
2014-01-01
Epidural anesthesia is a common anesthesia method yet up to 10% of procedures fail to provide adequate analgesia. This is usually due to misinterpreting the tactile information derived from the advancing needle through the complex tissue planes. Incorrect placement also can cause dural puncture and neural injury. We developed an optic system capable of reliably identifying tissue planes surrounding the epidural space. However the new technology was too large and cumbersome for practical clinical use. We present a miniaturized version of our optic system using chip technology (first generation CMOS-based system) for logic functions. The new system was connected to an alarm that was triggered once the optic properties of the epidural were identified. The aims of this study were to test our miniaturized system in a porcine model and describe the technology to build this new clinical tool. Our system was tested in a porcine model and identified the epidural space in the lumbar, low and high thoracic regions of the spine. The new technology identified the epidural space in all but 1 of 46 attempts. Experimental results from our fabricated integrated circuit and animal study show the new tool has future clinical potential. PMID:25162150
Sigmoid irrigation tube for the management of chronic evacuation disorders.
Gauderer, Michael W L; Decou, James M; Boyle, John T
2002-03-01
Antegrade colonic irrigation, in which the right colon is accessed via appendicostomy or cecostomy, now is an important adjunct in the management of children with chronic evacuation disorders. However, in most children, the major area of dysfunction is the left rather than the right colon. The authors developed a simple, percutaneous endoscopic, laparoscopically controlled sigmoid irrigation tube placement and evaluated the results in 4 children. A rigid sigmoidoscope is advanced into the upper sigmoid and the loop brought in contact with the abdominal wall under laparoscopic control. A small skin incision is made and a needle pushed across the abdominal and sigmoid walls into the lumen of the sigmoidoscope. A guide wire is advanced through the needle into the scope and retrieved. After the scope is removed, a PEG-type catheter is attached to the guide wire and pulled back, securing the sigmoid loop to the abdominal wall. The tube is subsequently converted to a skin-level device by simply adding an external port valve. All 4 patients achieved prompt evacuation in the sitting position. Sigmoid tube for antegrade irrigation is an appealing alternative to conventional cecal access. The procedure is simple and may offer physiologic advantages. Copyright 2002 by W.B. Saunders Company.
Investigation of an intelligent system for fiber optic-based epidural anesthesia.
Gong, Cihun-Siyong Alex; Ting, Chien-Kun
2014-01-01
Even though there have been many approaches to assist the anesthesiologists in performing regional anesthesia, none of the prior arts may be said as an unrestricted technique. The lack of a design that is with sufficient sensitivity to the targets of interest and automatic indication of needle placement makes it difficult to all-round implementation of field usage of objectiveness. In addition, light-weight easy-to-use realization is the key point of portability. This paper reports on an intelligent system of epidural space identification using optical technique, with particular emphasis on efficiency-enhanced aspects. Statistical algorithms, implemented in a dedicated field-programmable hardware platform along with an on-platform application-specific integrated chip, used to advance real-time self decision making in needle advancement are discussed together with the feedback results. Clinicians' viewpoint of improving the correct rate of our technique is explained in detail. Our study demonstrates not only that the improved system is able to behave as if it is a skillful anesthesiologist but also it has potential to bring promising assist into clinical use under varied conditions and small amount of sample, provided that several concerns are addressed.
Lopez, A M; Sala-Blanch, X; Castillo, R; Hadzic, A
2014-01-01
The recommendations for the level of injection and ideal placement of the needle tip required for successful ultrasound-guided sciatic popliteal block vary among authors. A hypothesis was made that, when the local anesthetic is injected at the division of the sciatic nerve within the common connective tissue sheath, the block has a higher success rate than an injection outside the sheath. Thirty-four patients scheduled for hallux valgus repair surgery were randomized to receive either a sub-sheath block (n=16) or a peri-sheath block (n=18) at the level of the division of the sciatic nerve at the popliteal fossa. For the sub-sheath block, the needle was advanced out of plane until the tip was positioned between the tibial and peroneal nerves, and local anesthetic was then injected without moving the needle. For the peri-sheath block, the needle was advanced out of plane both sides of the sciatic nerve, to surround the sheath. Mepivacaine 1.5% and levobupivacaine 0.5% 30mL were used in both groups. The progression of motor and sensory block was assessed at 5min intervals. Duration of block was recorded. Adequate surgical block was achieved in all patients in the subsheath group (100%) compared to 12 patients (67%) in the peri-sheath group at 30min. Sensory block was achieved faster in the subsheath than peri-sheath (9.1±7.4min vs. 19.0±4.0; p<.001). Our study suggests that for successful sciatic popliteal block in less than 30min, local anesthetic should be injected within the sheath. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Ince, Ilker; Arı, Muhammet Ali; Sulak, Muhammet Mustafa; Aksoy, Mehmet
There are different ultrasound probe positions used for internal jugular venous catheter placement. Also, in-plane or out of plane needle approach may be used for catheterization. Transverse short-axis classic approach is the most popular performed approach in literature. "Syringe-Free" is a new described technique that is performed with oblique long-axis approach. We aimed to compare performance of these two approaches. This study was conducted as a prospective and randomized study. 80 patients were included the study and divided into two groups that were named Group C (transverse short-axis classic approach) and Group SF (oblique long-axis syringe-free approach) by a computer-generated randomization. The primary outcome was mean time that guidewire is seen in the internal jugular vein (performing time). The secondary outcomes were to compare number of needle pass, number of skin puncture and complications between two groups. Demographic and hemodynamic data were not significantly different. The mean performing time was 54.9±19.1s in Group C and 43.9±15.8s in Group SF. Significant differences were found between the groups (p=0.006). Mean number of needle pass was 3.2(±2.1) in Group C and 2.1(±1.6) in Group SF. There were statistically significant differences between two groups (p=0.002). The number of skin puncture was 1.6(±0.8) and 1.2(±0.5) in Group C and SF, respectively (p=0.027). "Syringe-Free" technique has lower performing time, number of needle pass and skin puncture. Also, it allows to follow progress of guide-wire under continuous ultrasound visualization and the procedure does not need assistance during catheter insertion. Namely, "Syringe-Free" is effective, safe and fast technique that may be used to place internal jugular venous catheter. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Fluoroscopic Placement of Double-Pigtail Ureteral Stents
Chen, Gregory L.
2001-01-01
Purpose: Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study. Materials and methods: Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted. Results: A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100% (89 of 89 cases). No stents migrated or required replacement. Stents were placed after ureteroscopic laser lithotripsy (53/89) and ureteroscopic tumor treatment (22/89). Cystoscopic visualization was used in 32 additional procedures requiring precise control (15 ureteral strictures and nine retrograde endopyelotomy). Conclusions: The fluoroscopic placement of ureteral stents is a safe and simple technique with a very high success rate. We have used cystoscopic placement only after incisional procedures such as retrograde endopyelotomy, stricture or ureterotomy. PMID:18493562
Chae, Sanghoon; Jung, Sung-Weon
2018-01-01
A survey of 67 experienced orthopedic surgeons indicated that precise portal placement was the most important skill in arthroscopic surgery. However, none of the currently available virtual reality simulators include simulation / training in portal placement, including haptic feedback of the necessary puncture force. This study aimed to: (1) measure the in vivo force and stiffness during a portal placement procedure in an actual operating room and (2) implement active haptic simulation of a portal placement procedure using the measured in vivo data. We measured the force required for port placement and the stiffness of the joint capsule during portal placement procedures performed by an experienced arthroscopic surgeon. Based on the acquired mechanical property values, we developed a cable-driven active haptic simulator designed to train the portal placement skill and evaluated the validity of the simulated haptics. Ten patients diagnosed with rotator cuff tears were enrolled in this experiment. The maximum peak force and joint capsule stiffness during posterior portal placement procedures were 66.46 (±10.76N) and 2560.82(±252.92) N/m, respectively. We then designed an active haptic simulator using the acquired data. Our cable-driven mechanism structure had a friction force of 3.763 ± 0.341 N, less than 6% of the mean puncture force. Simulator performance was evaluated by comparing the target stiffness and force with the stiffness and force reproduced by the device. R-squared values were 0.998 for puncture force replication and 0.902 for stiffness replication, indicating that the in vivo data can be used to implement a realistic haptic simulator. PMID:29494691
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp
PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsymore » needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.« less
Blindness following cosmetic injections of the face.
Lazzeri, Davide; Agostini, Tommaso; Figus, Michele; Nardi, Marco; Pantaloni, Marcello; Lazzeri, Stefano
2012-04-01
Complications following facial cosmetic injections have recently heightened awareness of the possibility of iatrogenic blindness. The authors conducted a systematic review of the available literature to provide the best evidence for the prevention and treatment of this serious eye injury. The authors included in the study only the cases in which blindness was a direct consequence of a cosmetic injection procedure of the face. Twenty-nine articles describing 32 patients were identified. In 15 patients, blindness occurred after injections of adipose tissue; in the other 17, it followed injections of various materials, including corticosteroids, paraffin, silicone oil, bovine collagen, polymethylmethacrylate, hyaluronic acid, and calcium hydroxyapatite. Some precautions may minimize the risk of embolization of filler into the ophthalmic artery following facial cosmetic injections. Intravascular placement of the needle or cannula should be demonstrated by aspiration before injection and should be further prevented by application of local vasoconstrictor. Needles, syringes, and cannulas of small size should be preferred to larger ones and be replaced with blunt flexible needles and microcannulas when possible. Low-pressure injections with the release of the least amount of substance possible should be considered safer than bolus injections. The total volume of filler injected during the entire treatment session should be limited, and injections into pretraumatized tissues should be avoided. Actually, no safe, feasible, and reliable treatment exists for iatrogenic retinal embolism. Nonetheless, therapy should theoretically be directed to lowering intraocular pressure to dislodge the embolus into more peripheral vessels of the retinal circulation, increasing retinal perfusion and oxygen delivery to hypoxic tissues. Risk, V.
Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah
2013-01-01
Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941
Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Chen, Xiaojun; Hann, Alexander; Boechat, Pedro; Yu, Wei; Freisleben, Bernd; Alhonnoro, Tuomas; Pollari, Mika; Moche, Michael; Schmalstieg, Dieter
2015-01-01
In this contribution, we present a semi-automatic segmentation algorithm for radiofrequency ablation (RFA) zones via optimal s-t-cuts. Our interactive graph-based approach builds upon a polyhedron to construct the graph and was specifically designed for computed tomography (CT) acquisitions from patients that had RFA treatments of Hepatocellular Carcinomas (HCC). For evaluation, we used twelve post-interventional CT datasets from the clinical routine and as evaluation metric we utilized the Dice Similarity Coefficient (DSC), which is commonly accepted for judging computer aided medical segmentation tasks. Compared with pure manual slice-by-slice expert segmentations from interventional radiologists, we were able to achieve a DSC of about eighty percent, which is sufficient for our clinical needs. Moreover, our approach was able to handle images containing (DSC=75.9%) and not containing (78.1%) the RFA needles still in place. Additionally, we found no statistically significant difference (p<;0.423) between the segmentation results of the subgroups for a Mann-Whitney test. Finally, to the best of our knowledge, this is the first time a segmentation approach for CT scans including the RFA needles is reported and we show why another state-of-the-art segmentation method fails for these cases. Intraoperative scans including an RFA probe are very critical in the clinical practice and need a very careful segmentation and inspection to avoid under-treatment, which may result in tumor recurrence (up to 40%). If the decision can be made during the intervention, an additional ablation can be performed without removing the entire needle. This decreases the patient stress and associated risks and costs of a separate intervention at a later date. Ultimately, the segmented ablation zone containing the RFA needle can be used for a precise ablation simulation as the real needle position is known.
A fully actuated robotic assistant for MRI-guided prostate biopsy and brachytherapy
NASA Astrophysics Data System (ADS)
Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.
2013-03-01
Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm.
Tiriac, Herve; Bucobo, Juan Carlos; Tzimas, Demetrios; Grewel, Suman; Lacomb, Joseph F; Rowehl, Leahana M; Nagula, Satish; Wu, Maoxin; Kim, Joseph; Sasson, Aaron; Vignesh, Shivakumar; Martello, Laura; Munoz-Sagastibelza, Maria; Somma, Jonathan; Tuveson, David A; Li, Ellen; Buscaglia, Jonathan M
2018-06-01
Pancreatic cancer organoids are tumor models of individualized human pancreatic ductal adenocarcinoma (PDA), created from surgical specimens and used for personalized treatment strategies. Unfortunately, most patients with PDA are not operative candidates. Creation of human PDA organoids at the time of initial tumor diagnosis is therefore critical. Our aim was to assess the feasibility of creating human PDA organoids by EUS fine-needle biopsy (EUS-FNB) sampling in patients with PDA. In this prospective clinical trial in patients referred to evaluate a pancreatic mass, EUS-FNA was performed for initial onsite diagnosis. Two additional needle passes were performed with a 22-gauge FNB needle for organoid creation. Primary outcome was successful isolation of organoids within 2 weeks of EUS-FNB sampling (P0, no passages), confirmed by organoid morphology and positive genotyping. Thirty-seven patients with 38 PDA tumors were enrolled. Successful isolation of organoids (P0) was achieved in 33 of 38 tumors (87%). Establishment of PDA organoid lines for ≥5 passages of growth (P5, five passages) was reached in 25 of 38 tumors (66%). In the single patient with successful P5 FNB sampling-derived and P5 surgically derived organoids, there was identical matching of specimens. There were no serious adverse events. Two patients developed bleeding at the EUS-FNB puncture site requiring hemostasis clips. Pancreatic cancer organoids can be successfully and rapidly created by means of EUS-FNB sampling using a 22-gauge needle at the time of initial diagnosis. Successful organoid generation is essential for precision medicine in patients with pancreatic cancer in whom most are not surgically resectable. (Clinical trial registration number: NCT03140592.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Muralha, Nuno; Oliveira, Manuel; Ferreira, Maria Amélia; Costa-Maia, José
2017-05-31
Virtual reality simulation is a topic of discussion as a complementary tool to traditional laparoscopic surgical training in the operating room. However, it is unclear whether virtual reality training can have an impact on the surgical performance of advanced laparoscopic procedures. Our objective was to assess the ability of the virtual reality simulator LAP Mentor to identify and quantify changes in surgical performance indicators, after LAP Mentor training for digestive anastomosis. Twelve surgeons from Centro Hospitalar de São João in Porto (Portugal) performed two sessions of advanced task 5: anastomosis in LAP Mentor, before and after completing the tutorial, and were evaluated on 34 surgical performance indicators. The results show that six surgical performance indicators significantly changed after LAP Mentor training. The surgeons performed the task significantly faster as the median 'total time' significantly reduced (p < 0.05) from 759.5 to 523.5 seconds. Significant decreases (p < 0.05) were also found in median 'total needle loading time' (303.3 to 107.8 seconds), 'average needle loading time' (38.5 to 31.0 seconds), 'number of passages in which the needle passed precisely through the entrance dots' (2.5 to 1.0), 'time the needle was held outside the visible field' (20.9 to 2.4 seconds), and 'total time the needle-holders' ends are kept outside the predefined operative field' (88.2 to 49.6 seconds). This study raises the possibility of using virtual reality training simulation as a benchmark tool to assess the surgical performance of Portuguese surgeons. LAP Mentor is able to identify variations in surgical performance indicators of digestive anastomosis.
Zhang, Sheng; Su, Wanhan; Luo, Qiang; Leung, Frankie; Chen, Bin
2014-01-01
This study is aimed at definition of the safe and dangerous zone for screw placement with Stoppa approach for rapid identification during operation and a new way for the studies on the "safe zone." Pelvic CT data of 84 human subjects were recruited to reconstruct the three-dimensional (3D) models. The distances between the edges of the "safe zone," "dangerous zone," and specific anatomic landmarks such as the obturator canal and the pelvic brim were precisely measured, respectively. The results show that the absolute "dangerous zone" was from the pelvic brim to 3.07 cm below it and within 2.86 cm of the obturator canal, while the region 3.56 cm below the pelvic brim or 3.85 cm away from the obturator canal was the absolute "safe zone" for screw placement. The region between the absolute "safe zone" and the absolute "dangerous zone" was the relatively "dangerous zone." As a conclusion, application of computer-assisted 3D modeling techniques aids in the precise measurement of "safe zone" and "dangerous zone" in combination with Stoppa incision. It was not recommended to place screws on the absolute dangerous zone, while, for the relatively "dangerous zone," it depends on the individual variations in bony anatomy and the fracture type.
Patel, Nitesh V; Mian, Matthew; Stafford, R Jason; Nahed, Brian V; Willie, Jon T; Gross, Robert E; Danish, Shabbar F
2016-12-01
Laser-induced thermal therapy has become a powerful tool in the neurosurgical armamentarium. The physics of laser therapy are complex, but a sound understanding of this topic is clinically relevant, as many centers have incorporated it into their treatment algorithm, and educated patients are demanding consideration of its use for their disease. Laser ablation has been used for a wide array of intracranial lesions. Laser catheter placement is guided by stereotactic planning; however, as the procedure has popularized, the number of ways in which the catheter can be inserted has also increased. There are many technical nuances for laser placement, and, to date, there is not a clear understanding of whether any one technique is better than the other. In this review, we describe the basic physics of magnetic resonance-guided laser-induced thermal therapy and describe the several common techniques for accurate Visualase laser catheter placement in a stepwise fashion. MRg-LITT, magnetic resonance-guided laser-induced thermal therapyPAD, precision aiming device.
NASA Astrophysics Data System (ADS)
Giacometti, Paolo; Diamond, Solomon G.
2013-02-01
A noninvasive head probe that combines near-infrared spectroscopy (NIRS) and electroencephalography (EEG) for simultaneous measurement of neural dynamics and hemodynamics in the brain is presented. It is composed of a compliant expandable mechanism that accommodates a wide range of head size variation and an elastomeric web that maintains uniform sensor contact pressure on the scalp as the mechanism expands and contracts. The design is intended to help maximize optical and electrical coupling and to maintain stability during head movement. Positioning electrodes at the inion, nasion, central, and preauricular fiducial locations mechanically shapes the probe to place 64 NIRS optodes and 65 EEG electrodes following the 10-5 scalp coordinates. The placement accuracy, precision, and scalp pressure uniformity of the sensors are evaluated. A root-mean-squared (RMS) positional precision of 0.89±0.23 mm, percent arc subdivision RMS accuracy of 0.19±0.15%, and mean normal force on the scalp of 2.28±0.88 N at 5 mm displacement were found. Geometric measurements indicate that the probe will accommodate the full range of adult head sizes. The placement accuracy, precision, and uniformity of sensor contact pressure of the proposed head probe are important determinants of data quality in noninvasive brain monitoring with simultaneous NIRS-EEG.
Integrating three-dimensional digital technologies for comprehensive implant dentistry.
Patel, Neal
2010-06-01
The increase in the popularity of and the demand for the use of dental implants to replace teeth has encouraged advancement in clinical technology and materials to improve patients' acceptance and clinical outcomes. Recent advances such as three-dimensional dental radiography with cone-beam computed tomography (CBCT), precision dental implant planning software and clinical execution with guided surgery all play a role in the success of implant dentistry. The author illustrates the technique of comprehensive implant dentistry planning through integration of computer-aided design/computer-aided manufacturing (CAD/CAM) and CBCT data. The technique includes clinical treatment with guided surgery, including the creation of a final restoration with a high-strength ceramic (IPS e.max CAD, Ivoclar Vivadent, Amherst, N.Y.). The author also introduces a technique involving CAD/CAM for fabricating custom implant abutments. The release of software integrating CEREC Acquisition Center with Bluecam (Sirona Dental Systems, Charlotte, N.C.) chairside CAD/CAM and Galileos CBCT imaging (Sirona Dental Systems) allows dentists to plan implant placement, perform implant dentistry with increased precision and provide predictable restorative results by using chairside IPS e.max CAD. The precision of clinical treatment provided by the integration of CAD/CAM and CBCT allows dentists to plan for ideal surgical placement and the appropriate thickness of restorative modalities before placing implants.
Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips
Schulz-Wendtland, R.; Dankerl, P.; Dilbat, G.; Bani, M.; Fasching, P. A.; Heusinger, K.; Lux, M. P.; Loehberg, C. R.; Jud, S. M.; Rauh, C.; Bayer, C. M.; Beckmann, M. W.; Wachter, D. L.; Uder, M.; Meier-Meitinger, M.; Brehm, B.
2015-01-01
Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography. PMID:25684789
CT-Guided Percutaneous Biopsy of Intrathoracic Lesions
Lal, Hira; Nath, Alok; Borah, Samudra
2012-01-01
Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications. PMID:22438689
Pole-placement Predictive Functional Control for under-damped systems with real numbers algebra.
Zabet, K; Rossiter, J A; Haber, R; Abdullah, M
2017-11-01
This paper presents the new algorithm of PP-PFC (Pole-placement Predictive Functional Control) for stable, linear under-damped higher-order processes. It is shown that while conventional PFC aims to get first-order exponential behavior, this is not always straightforward with significant under-damped modes and hence a pole-placement PFC algorithm is proposed which can be tuned more precisely to achieve the desired dynamics, but exploits complex number algebra and linear combinations in order to deliver guarantees of stability and performance. Nevertheless, practical implementation is easier by avoiding complex number algebra and hence a modified formulation of the PP-PFC algorithm is also presented which utilises just real numbers while retaining the key attributes of simple algebra, coding and tuning. The potential advantages are demonstrated with numerical examples and real-time control of a laboratory plant. Copyright © 2017 ISA. All rights reserved.
Design and preliminary accuracy studies of an MRI-guided transrectal prostate intervention system.
Krieger, Axel; Csoma, Csaba; Iordachital, Iulian I; Guion, Peter; Singh, Anurag K; Fichtinger, Gabor; Whitcomb, Louis L
2007-01-01
This paper reports a novel system for magnetic resonance imaging (MRI) guided transrectal prostate interventions, such as needle biopsy, fiducial marker placement, and therapy delivery. The system utilizes a hybrid tracking method, comprised of passive fiducial tracking for initial registration and subsequent incremental motion measurement along the degrees of freedom using fiber-optical encoders and mechanical scales. Targeting accuracy of the system is evaluated in prostate phantom experiments. Achieved targeting accuracy and procedure times were found to compare favorably with existing systems using passive and active tracking methods. Moreover, the portable design of the system using only standard MRI image sequences and minimal custom scanner interfacing allows the system to be easily used on different MRI scanners.
Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara
2004-01-23
High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.
NASA Astrophysics Data System (ADS)
Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.
2015-03-01
Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.
NASA Technical Reports Server (NTRS)
Stroupe, Ashley W.; Okon, Avi; Robinson, Matthew; Huntsberger, Terry; Aghazarian, Hrand; Baumgartner, Eric
2004-01-01
Robotic Construction Crew (RCC) is a heterogeneous multi-robot system for autonomous acquisition, transport, and precision mating of components in construction tasks. RCC minimizes resources constrained in a space environment such as computation, power, communication and, sensing. A behavior-based architecture provides adaptability and robustness despite low computational requirements. RCC successfully performs several construction related tasks in an emulated outdoor environment despite high levels of uncertainty in motions and sensing. Quantitative results are provided for formation keeping in component transport, precision instrument placement, and construction tasks.
Khater, Nazih; Shen, Jim; Arenas, Javier; Keheila, Mohamed; Alsyouf, Muhannad; Martin, Jacob A; Lightfoot, Michelle A; Li, Roger; Olgin, Gaudencio; Smith, Jason C; Baldwin, D Duane
2016-11-01
Traditional techniques for obtaining percutaneous renal access utilize continuous fluoroscopy. In an attempt to minimize radiation exposure, we describe a novel laser direct alignment radiation reduction technique (DARRT) for percutaneous access and test it in a bench-top model. In this randomized-controlled bench-top study, 20 medical personnel obtained renal accesses using both the conventional bullseye technique and the laser DARRT. The primary endpoint was total fluoroscopy time. Secondary endpoints included insertion time, puncture attempts, course corrections, and subjective procedural difficulty. In the laser DARRT, fluoroscopy was used with the C-arm positioned with the laser beam at a 30° angle. The access needle and hub were aligned with the laser beam. Effective caliceal puncture was confirmed with fluoroscopy and direct vision. The Paired samples Wilcoxon signed rank test was used for statistical analysis with significance at p < 0.05. A total of 120 needle placements were recorded. Fluoroscopy time for needle access using the laser DARRT was significantly lower than the bullseye technique in all groups as follows: attendings (7.09 vs 18.51 seconds; p < 0.001), residents (6.55 vs 13.93 seconds; p = 0.001), and medical students (6.69 vs 20.22 seconds; p < 0.001). Students rated the laser DARRT easier to use (2.56 vs 4.89; p < 0.001). No difference was seen in total access time, puncture attempts, or course corrections between techniques. The laser DARRT reduced fluoroscopy time by 63%, compared with the conventional bullseye technique. The least experienced users found the laser DARRT significantly easier to learn. This novel technique is promising and merits additional testing in animal and human models.
Randomized Controlled Trial of a Special Acupuncture Technique for Pain after Thoracotomy
Deng, Gary; Rusch, Valerie; Vickers, Andrew; Malhortra, Vivek; Ginex, Pamela; Downey, Robert; Bains, Manjit; Park, Bernard; Rizk, Nabil; Flores, Raja; Yeung, Simon; Cassileth, Barrie
2009-01-01
Objective To determine whether an acupuncture technique specially developed for a surgical oncology population (intervention) reduces pain or analgesic use after thoracotomy compared to a sham acupuncture technique (control). Methods One hundred and sixty two cancer patients undergoing thoracotomy were randomized to group A) preoperative implantation of small intradermal needles which were retained for 4 weeks or B) preoperative placement of sham needles at the same schedule. Numerical Rating Scale (NRS) of pain and total opioid use we evaluated during the in-patient stay; Brief Pain Inventory (BPI) and Medication Quantification Scale (MQS) were evaluated after discharge up to 3 months after the surgery. Results The principal analysis, a comparison of BPI pain intensity scores at the 30 day follow-up, showed no significant difference between the intervention and control group. Pain scores were marginally higher in the intervention group 0.05 (95% C.I.: 0.74, -0.64; p=0.9). There were also no statistically significant differences between groups for secondary endpoints, including chronic pain assessments at 60 and 90 days, in-patient pain, and medication use in hospital and after discharge. Conclusion A special acupuncture technique as provided in this study did not reduce pain or use of pain medication after thoracotomy more than a sham technique. PMID:19114190
Rombouts, Steffi J E; van Dijck, Willemijn P M; Nijkamp, Maarten W; Derksen, Tyche C; Brosens, Lodewijk A A; Hoogwater, Frederik J H; van Leeuwen, Maarten S; Borel Rinkes, Inne H M; van Hillegersberg, Richard; Wittkampf, Fred H; Molenaar, Izaak Q
2017-12-01
Irreversible electroporation (IRE) by inserting needles around the tumor as treatment for locally advanced pancreatic cancer entails several disadvantages, such as incomplete ablation due to field inhomogeneity, technical difficulties in needle placement and a risk of pancreatic fistula development. This experimental study evaluates outcomes of IRE using paddles in a porcine model. Six healthy pigs underwent laparotomy and were treated with 2 separate ablations (in head and tail of the pancreas). Follow-up consisted of clinical and laboratory parameters and contrast-enhanced computed tomography (ceCT) imaging. After 2 weeks, pancreatoduodenectomy was performed for histology and the pigs were terminated. All animals survived 14 days. None of the animals developed signs of infection or significant abdominal distention. Serum amylase and lipase peaked at day 1 postoperatively in all pigs, but normalized without signs of pancreatitis. On ceCT-imaging the ablation zone was visible as an ill-defined, hypodense lesion. No abscesses, cysts or ascites were seen. Histology showed a homogenous fibrotic lesion in all pigs. IRE ablation of healthy porcine pancreatic tissue using two plate electrodes is feasible and safe and creates a homogeneous fibrotic lesion. IRE-paddles should be tested on pancreatic adenocarcinoma to determine the effect in cancer tissue. Copyright © 2017. Published by Elsevier Ltd.
Stone, Jonathan; Matchett, Gerald
2014-01-01
Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.
Robot-assisted antegrade in-situ fenestrated stent grafting.
Riga, Celia V; Bicknell, Colin D; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas
2009-05-01
To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.
Thrust Force Analysis of Tripod Constant Velocity Joint Using Multibody Model
NASA Astrophysics Data System (ADS)
Sugiura, Hideki; Matsunaga, Tsugiharu; Mizutani, Yoshiteru; Ando, Yosei; Kashiwagi, Isashi
A tripod constant velocity joint is used in the driveshaft of front wheel drive vehicles. Thrust force generated by this joint causes lateral vibration in these vehicles. To analyze the thrust force, a detailed model is constructed based on a multibody dynamics approach. This model includes all principal parts of the joint defined as rigid bodies and all force elements of contact and friction acting among these parts. This model utilizes a new contact modeling method of needle roller bearings for more precise and faster computation. By comparing computational and experimental results, the appropriateness of this model is verified and the principal factors inducing the second and third rotating order components of the thrust force are clarified. This paper also describes the influence of skewed needle rollers on the thrust force and evaluates the contribution of friction forces at each contact region to the thrust force.
MR guided FUS therapy with a Robotic Assistance System
NASA Astrophysics Data System (ADS)
Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael
2009-04-01
Magnetic Resonance imaging guided Focus Ultrasound Surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. To date, there is only one commercial MRgFUS system available and only a few are in a prototype stage. The objective of this ongoing project is to establish an MRgFUS therapy unit as add-on for a commercially available robotic assistance system originally designed for percutaneous needle interventions in whole-body MR scanners.
Image-guided smart laser system for precision implantation of cells in cartilage
NASA Astrophysics Data System (ADS)
Katta, Nitesh; Rector, John A.; Gardner, Michael R.; McElroy, Austin B.; Choy, Kevin C.; Crosby, Cody; Zoldan, Janet; Milner, Thomas E.
2017-03-01
State-of-the-art treatment for joint diseases like osteoarthritis focus on articular cartilage repair/regeneration by stem cell implantation therapy. However, the technique is limited by a lack of precision in the physician's imaging and cell deposition toolkit. We describe a novel combination of high-resolution, rapid scan-rate optical coherence tomography (OCT) alongside a short-pulsed nanosecond thulium (Tm) laser for precise cell seeding in cartilage. The superior beam quality of thulium lasers and wavelength of operation 1940 nm offers high volumetric tissue removal rates and minimizes the residual thermal footprint. OCT imaging enables targeted micro-well placement, precise cell deposition, and feature contrast. A bench-top system is constructed using a 15 W, 1940 nm, nanosecond-pulsed Tm fiber laser (500 μJ pulse energy, 100 ns pulse duration, 30kHz repetition rate) for removing tissue, and a swept source laser (1310 ± 70 nm, 100 kHz sweep rate) for OCT imaging, forming a combined Tm/OCT system - a "smart laser knife". OCT assists the smart laser knife user in characterizing cartilage to inform micro-well placement. The Tm laser creates micro-wells (2.35 mm diameter length, 1.5 mm width, 300 μm deep) and micro-incisions (1 mm wide, 200 μm deep) while OCT image-guidance assists and demonstrates this precision cutting and cell deposition with real-time feedback. To test micro-well creation and cell deposition protocol, gelatin phantoms are constructed mimicking cartilage optical properties and physiological structure. Cell viability is then assessed to illustrate the efficacy of the hydrogel deposition. Automated OCT feedback is demonstrated for cutting procedures to avoid important surface/subsurface structures. This bench-top smart laser knife system described here offers a new image-guided approach to precise stem cell seeding that can enhance the efficacy of articular cartilage repair.
Roberts, Chris; Shadbolt, Narelle; Clark, Tyler; Simpson, Phillip
2014-09-20
Little is known about the technical adequacy of portfolios in reporting multiple complex academic and performance-based assessments. We explored, first, the influencing factors on the precision of scoring within a programmatic assessment of student learning outcomes within an integrated clinical placement. Second, the degree to which validity evidence supported interpretation of student scores. Within generalisability theory, we estimated the contribution that each wanted factor (i.e. student capability) and unwanted factors (e.g. the impact of assessors) made to the variation in portfolio task scores. Relative and absolute standard errors of measurement provided a confidence interval around a pre-determined pass/fail standard for all six tasks. Validity evidence was sought through demonstrating the internal consistency of the portfolio and exploring the relationship of student scores with clinical experience. The mean portfolio mark for 257 students, across 372 raters, based on six tasks, was 75.56 (SD, 6.68). For a single student on one assessment task, 11% of the variance in scores was due to true differences in student capability. The most significant interaction was context specificity (49%), the tendency for one student to engage with one task and not engage with another task. Rater subjectivity was 29%. An absolute standard error of measurement of 4.74%, gave a 95% CI of +/- 9.30%, and a 68% CI of +/- 4.74% around a pass/fail score of 57%. Construct validity was supported by demonstration of an assessment framework, the internal consistency of the portfolio tasks, and higher scores for students who did the clinical placement later in the academic year. A portfolio designed as a programmatic assessment of an integrated clinical placement has sufficient evidence of validity to support a specific interpretation of student scores around passing a clinical placement. It has modest precision in assessing students' achievement of a competency standard. There were identifiable areas for reducing measurement error and providing more certainty around decision-making. Reducing the measurement error would require engaging with the student body on the value of the tasks, more focussed academic and clinical supervisor training, and revisiting the rubric of the assessment in the light of feedback.
Peltan, Ithan D.; Shiga, Takashi; Gordon, James A.; Currier, Paul F.
2015-01-01
Background Simulation training may improve proficiency at and reduces complications from central venous catheter (CVC) placement, but the scope of simulation’s effect remains unclear. This randomized controlled trial evaluated the effects of a pragmatic CVC simulation program on procedural protocol adherence, technical skill, and patient outcomes. Methods Internal medicine interns were randomized to standard training for CVC insertion or standard training plus simulation-based mastery training. Standard training involved a lecture, a video-based online module, and instruction by the supervising physician during actual CVC insertions. Intervention-group subjects additionally underwent supervised training on a venous access simulator until they demonstrated procedural competence. Raters evaluated interns’ performance during internal jugular CVC placement on actual patients in the medical intensive care unit. Generalized estimating equations were used to account for outcome clustering within trainees. Results We observed 52 interns place 87 CVCs. Simulation-trained interns exhibited better adherence to prescribed procedural technique than interns who received only standard training (p=0.024). There were no significant differences detected in first-attempt or overall cannulation success rates, mean needle passes, global assessment scores or complication rates. Conclusions Simulation training added to standard training improved protocol adherence during CVC insertion by novice practitioners. This study may have been too small to detect meaningful differences in venous cannulation proficiency and other clinical outcomes, highlighting the difficulty of patient-centered simulation research in settings where poor outcomes are rare. For high-performing systems, where protocol deviations may provide an important proxy for rare procedural complications, simulation may improve CVC insertion quality and safety. PMID:26154250
Aslanian, Harry R; Estrada, Juan D; Rossi, Federico; Dziura, James; Jamidar, Priya A; Siddiqui, Uzma D
2011-09-01
Endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) are complementary procedures in the evaluation of obstructive jaundice. To determine the feasibility, accuracy, and safety of the combined performance of EUS-guided fine needle aspiration (FNA) and ERCP with biliary stenting in patients with obstructive jaundice. Retrospectively reviewed data from consecutive patients presenting with obstructive jaundice due to a pancreas mass at a tertiary referral hospital between April 2002 and November 2007 who underwent combined (under the same sedation and in the same room) or separate EUS and ERCP. Procedure duration, amount of sedative medication administered, ability to achieve biliary stent placement, and the diagnostic yield of EUS-FNA were evaluated. A total of 47 patients were evaluated: 29 patients underwent combined EUS and ERCP and 18 had separate procedures (median of 5 d between procedures). Stent placement at ERCP was successful in 72% combined procedures versus 88% separate ERCP. EUS-FNA diagnosis of malignancy was positive in 91.6% combined versus 87.5% separate. The only complication was self-limited melena after a combined procedure in 1 patient. The median time for combined procedures was 75 minutes versus 50 minutes for separate EUS and 50 minutes for ERCP. Combined EUS and ERCP can be performed under the same sedation with a median 25 minute greater procedure length and similarly high yields for diagnostic EUS-FNA. A nonsignificant trend toward lower biliary stent placement success rates with combined ERCP procedures merits further study. Benefits of a combined procedure may include expedited patient evaluation and the avoidance of repeated sedation.
Avella, Diego M; Toth, Jennifer W; Reed, Michael F; Gusani, Niraj J; Kimchi, Eric T; Mahraj, Rickeshvar P; Staveley-O'Carroll, Kevin F; Kaifi, Jussuf T
2015-04-11
Percutaneous drainage of infected intraabdominal fluid collections is preferred over surgical drainage due to lower morbidity and costs. However, it can be a challenging procedure and catheter insertion carries the potential to contaminate the pleural space from the abdomen. This retrospective analysis demonstrates the clinical and radiographic correlation between percutaneous drainage of infected intraabdominal collections and the development of iatrogenic pleural space infections. A retrospective single institution analysis of 550 consecutive percutaneous drainage procedures for intraabdominal fluid collections was performed over 24 months. Patient charts and imaging were reviewed with regard to pleural space infections that were attributed to percutaneous drain placements. Institutional review board approval was obtained for conduct of the study. 6/550 (1.1%) patients developed iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections. All 6 patients presented with respiratory symptoms and required pleural space drainage (either by needle aspiration or chest tube placement), 2 received intrapleural fibrinolytic therapy and 1 patient had to undergo surgical drainage. Pleural effusion cultures revealed same bacteria in both intraabdominal and pleural fluid in 3 (50%) cases. A video with a dynamic radiographic sequence demonstrating the contamination of the pleural space from percutaneous drainage of an infected intraabdominal collection is included. Iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections occur at a low incidence, but the pleural empyema can be progressive requiring prompt chest tube drainage, intrapleural fibrinolytic therapy or even surgery. Expertise in intraabdominal drain placements, awareness and early recognition of this complication is critical to minimize incidence, morbidity and mortality in these patients.
DOSESCREEN: a computer program to aid dose placement
Kimberly C. Smith; Jacqueline L. Robertson
1984-01-01
Careful selection of an experimental design for a bioassay substantially improves the precision of effective dose (ED) estimates. Design considerations typically include determination of sample size, dose selection, and allocation of subjects to doses. DOSESCREEN is a computer program written to help investigators select an efficient design for the estimation of an...
Coulthart, Michael B; Posada, David; Crandall, Keith A; Dekaban, Gregory A
2006-03-01
Recently, the putative finding of ancient human T cell leukemia virus type 1 (HTLV-1) long terminal repeat (LTR) DNA sequences in association with a 1500-year-old Chilean mummy has stirred vigorous debate. The debate is based partly on the inherent uncertainties associated with phylogenetic reconstruction when only short sequences of closely related genotypes are available. However, a full analysis of what phylogenetic information is present in the mummy data has not previously been published, leaving open the question of what precisely is the range of admissible interpretation. To fulfill this need, we re-analyzed the mummy data in a new way. We first performed phylogenetic analysis of 188 published LTR DNA sequences from extant strains belonging to the HTLV-1 Cosmopolitan clade, using the method of statistical parsimony which is designed both to optimize phylogenetic resolution among sequences with little evolutionary divergence, and to permit precise mapping of individual sequence mutations onto branches of a divergence network. We then deduced possible phylogenetic positions for the two main categories of published Chilean mummy sequences, based on their published 157-nucleotide LTR sequences. The possible phylogenetic placements for one of the mummy sequence categories are consistent with a modern origin. However, one of these placements for the other mummy sequence category falls very close to the root of the Cosmopolitan clade, consistent with an ancient origin for both this mummy sequence and the Cosmopolitan clade.
Prism adaptation and generalization during visually guided locomotor tasks.
Alexander, M Scott; Flodin, Brent W G; Marigold, Daniel S
2011-08-01
The ability of individuals to adapt locomotion to constraints associated with the complex environments normally encountered in everyday life is paramount for survival. Here, we tested the ability of 24 healthy young adults to adapt to a rightward prism shift (∼11.3°) while either walking and stepping to targets (i.e., precision stepping task) or stepping over an obstacle (i.e., obstacle avoidance task). We subsequently tested for generalization to the other locomotor task. In the precision stepping task, we determined the lateral end-point error of foot placement from the targets. In the obstacle avoidance task, we determined toe clearance and lateral foot placement distance from the obstacle before and after stepping over the obstacle. We found large, rightward deviations in foot placement on initial exposure to prisms in both tasks. The majority of measures demonstrated adaptation over repeated trials, and adaptation rates were dependent mainly on the task. On removal of the prisms, we observed negative aftereffects for measures of both tasks. Additionally, we found a unilateral symmetric generalization pattern in that the left, but not the right, lower limb indicated generalization across the 2 locomotor tasks. These results indicate that the nervous system is capable of rapidly adapting to a visuomotor mismatch during visually demanding locomotor tasks and that the prism-induced adaptation can, at least partially, generalize across these tasks. The results also support the notion that the nervous system utilizes an internal model for the control of visually guided locomotion.
Epidural steroids for treating "failed back surgery syndrome": is fluoroscopy really necessary?
Fredman, B; Nun, M B; Zohar, E; Iraqi, G; Shapiro, M; Gepstein, R; Jedeikin, R
1999-02-01
Epidural steroids are commonly administered in the treatment of "failed back surgery syndrome." Because patient response is dependent on accurate steroid placement, fluoroscopic guidance has been advocated. However, because of ever-increasing medical expenditures, the cost-benefit of routine fluoroscopy should be critically evaluated. Therefore, 50 patients were enrolled into this institutional review board-approved, prospective, controlled, single-blinded study. At a predetermined intervertebral level, the epidural space was identified using an air loss of resistance technique. Thereafter, an epidural catheter was inserted 2 cm through the epidural needle. To determine the accuracy of the clinical placement, contrast medium was administered through the epidural catheter; antero-posterior and lateral lumbar spine radiographs were then obtained. The number of attempts required to successfully locate the epidural space, the reliability of the air loss of resistance technique in indicating successful epidural penetration in failed back surgery syndrome, the ability of the clinician to accurately predict the intervertebral space at which the epidural injection was performed, and the spread of contrast medium within the epidural space were recorded. A total of 48 epidurograms were performed. The number of attempts to successfully enter the epidural space was 2 +/- 1. In 44 cases, the radiological studies confirmed the clinical impression that the epidural space had been successfully identified. In three patients, the epidural catheter was in the paravertebral tissue. One myelogram was recorded. In 25 patients, the epidural catheter did not pass through the predetermined intervertebral space. In 35 cases, the contrast medium did not reach the level of pathology. The clinical sign of loss of resistance is a reliable indicator of epidural space penetration in most cases of "failed back surgery syndrome." However, surface anatomy is unreliable and may result in inaccurate steroid placement. Finally, despite accurate placement, the depot-steroid solution will spread to reach the level of pathology in only 26% of cases.
Elsyad, Moustafa Abdou
2012-10-01
This article describes the fabrication of a new and inexpensive surgical template from a radiographic template for flapless placement of dental implants to retain a mandibular overdenture. A radiographic template with radiopaque metal plate markers is constructed and used as a guide for achieving three-dimensional evaluation of bone using computed tomography (CT). The potential position and angulation of the implants are measured relative to the metal plates using the CT data. The radiographic template is converted into a surgical template by attaching rigid metal rods that guide the handpiece precisely during subsequent drilling procedures. © 2012 by the American College of Prosthodontists.
Riegel, Adam C; Chen, Yu; Kapur, Ajay; Apicello, Laura; Kuruvilla, Abraham; Rea, Anthony J; Jamshidi, Abolghassem; Potters, Louis
Optically stimulated luminescent dosimeters (OSLDs) are utilized for in vivo dosimetry (IVD) of modern radiation therapy techniques such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Dosimetric precision achieved with conventional techniques may not be attainable. In this work, we measured accuracy and precision for a large sample of clinical OSLD-based IVD measurements. Weekly IVD measurements were collected from 4 linear accelerators for 2 years and were expressed as percent differences from planned doses. After outlier analysis, 10,224 measurements were grouped in the following way: overall, modality (photons, electrons), treatment technique (3-dimensional [3D] conformal, field-in-field intensity modulation, inverse-planned IMRT, and VMAT), placement location (gantry angle, cardinality, and central axis positioning), and anatomical site (prostate, breast, head and neck, pelvis, lung, rectum and anus, brain, abdomen, esophagus, and bladder). Distributions were modeled via a Gaussian function. Fitting was performed with least squares, and goodness-of-fit was assessed with the coefficient of determination. Model means (μ) and standard deviations (σ) were calculated. Sample means and variances were compared for statistical significance by analysis of variance and the Levene tests (α = 0.05). Overall, μ ± σ was 0.3 ± 10.3%. Precision for electron measurements (6.9%) was significantly better than for photons (10.5%). Precision varied significantly among treatment techniques (P < .0001) with field-in-field lowest (σ = 7.2%) and IMRT and VMAT highest (σ = 11.9% and 13.4%, respectively). Treatment site models with goodness-of-fit greater than 0.90 (6 of 10) yielded accuracy within ±3%, except for head and neck (μ = -3.7%). Precision varied with treatment site (range, 7.3%-13.0%), with breast and head and neck yielding the best and worst precision, respectively. Placement on the central axis of cardinal gantry angles yielded more precise results (σ = 8.5%) compared with other locations (range, 10.5%-11.4%). Accuracy of ±3% was achievable. Precision ranged from 6.9% to 13.4% depending on modality, technique, and treatment site. Simple, standardized locations may improve IVD precision. These findings may aid development of patient-specific tolerances for OSLD-based IVD. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Hamstring Graft Preparation Using a Modified Rolling Hitch Technique
Hong, Chih-Kai; Chang, Chih-Hsun; Chiang, Chen-Hao; Jou, I-Ming; Su, Wei-Ren
2014-01-01
Anterior cruciate ligament reconstruction using double-looped hamstring autograft is a common procedure in orthopaedic practice. However, during placement of the running, locking stitches at each end of the harvested tendons, the surgeon may face several potential obstacles, including the risk of damaging the tendon, predisposing the surgeon to needle-stick injury, and extended time consumption. We report a modified rolling hitch technique for hamstring graft preparation that is quick, cost-saving, and needleless as an alternative method. The original rolling hitch technique uses a traditional knot that attaches a rope to an object; the modified rolling hitch technique was created by adding 1 more turn before finishing with a half-hitch, which may prevent suture slippage off the tendon, thus providing sufficient fixation of the suture-tendon construct. PMID:25126495
A case of stapler pin in the root canal--extending beyond the apex.
Rao, A; Sudha, P
1999-01-01
There have been several reports describing the placement, by patients, of foreign objects into exposed pulp chambers and canals. In the present case, a 13-year-old patient reported with complaints of pain and a history of inserting a foreign object into the root canal of the left central incisor. On examination the foreign body was found to be a stapler pin which was projecting 5 millimeters from the apical foramen. Foreign bodies discovered from the root canal have varied from radiolucent objects like wooden tooth picks or tooth brush bristles to radioopaque materials like paper pins, needles, pencil leads etc. In the present case, despite our best efforts, the patient did not agree to undergo any treatment except for the extraction of the left central incisor.
Treatment Planning and Image Guidance for Radiofrequency Ablations of Large Tumors
Ren, Hongliang; Campos-Nanez, Enrique; Yaniv, Ziv; Banovac, Filip; Abeledo, Hernan; Hata, Nobuhiko; Cleary, Kevin
2014-01-01
This article addresses the two key challenges in computer-assisted percutaneous tumor ablation: planning multiple overlapping ablations for large tumors while avoiding critical structures, and executing the prescribed plan. Towards semi-automatic treatment planning for image-guided surgical interventions, we develop a systematic approach to the needle-based ablation placement task, ranging from pre-operative planning algorithms to an intra-operative execution platform. The planning system incorporates clinical constraints on ablations and trajectories using a multiple objective optimization formulation, which consists of optimal path selection and ablation coverage optimization based on integer programming. The system implementation is presented and validated in phantom studies and on an animal model. The presented system can potentially be further extended for other ablation techniques such as cryotherapy. PMID:24235279
Laser and radiofrequency-induced hyperthermia treatment via gold-coated magnetic nanocomposites
Elsherbini, Alsayed AM; Saber, Mahmoud; Aggag, Mohamed; El-Shahawy, Ahmed; Shokier, Hesham AA
2011-01-01
Introduction The current radiofrequency ablation technique requires invasive needle placement. On the other hand, most of the common photothermal therapeutic methods are limited by lack of accuracy of targeting. Gold and magnetic nanoparticles offer the potential to heat tumor tissue selectively at the cellular level by noninvasive interaction with laser and radiofrequency. Methods Gold nanospheres and gold-coated magnetic nanocomposites were used for inducing hyperthermia to treat subcutaneous Ehrlich carcinoma implanted in female mice. Results In mice treated with gold nanospheres, tumors continued to grow but at a slow rate. In contrast, more than 50% of the tumors treated with gold-coated magnetic nanocomposites completely disappeared. Conclusion This simple and noninvasive method shows great promise as a technique for selective magnetic photothermal treatment. PMID:22114479
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippiadis, D., E-mail: dfilippiadis@yahoo.gr; Gkizas, C., E-mail: chgkizas@gmail.com; Kostantos, C., E-mail: drkarpen@yahoo.gr
PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drillingmore » including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.« less
Yigitbas, Hakan; Yazici, Pinar; Taskin, Halit E; Okoh, Alexis K; Dural, Cem; Aydin, Nail; Berber, Eren
2017-02-01
The management of disappearing colorectal liver metastases in the postadjuvant chemotherapy setting is challenging. We describe a novel technique that facilitates laparoscopic resection of disappearing metastatic liver lesions with great precision. Details of this new technique are described in 2 patients with colorectal cancer synchronously metastatic to the liver. Both patients had small indistinct intraparenchymal liver lesions after adjuvant chemotherapy. A video displays the steps of the procedure. Both patients presented with colorectal cancer with synchronous liver metastasis. They received FOLFOX regimen after resection of their primary. They both responded to adjuvant chemotherapy. On repeat posttreatment imaging, the liver lesions became smaller and indistinct. With laparoscopic ultrasound, subtle parenchymal heterogeneities were identified. The lesions were initially ablated with a wide radiofrequency ablation zone. Then, without removing the needle, the prongs were deployed to the borders of the parenchymal heterogeneity. Using an ultrasonic vessel sealer, the lesions were resected. Final pathology identified 1 viable focus of cancer in each patient. Both patients were discharged home uneventfully on their second postoperative day. There were no complications. We have described a novel technique that could facilitate precise resection of intraparenchymal small indistinct or disappearing liver metastases of colorectal origin. This option should be kept within the armamentarium of the laparoscopic liver surgeon managing patients with malignant liver tumors.
Pulgaonkar, Rohan; Chitra, Prasad
2015-11-01
An unusual case of altered passive eruption with gingival hyperpigmentation and a Class I malocclusion in a 12-year-old girl having no previous history of medication is presented. The patient reported with spacing in the upper arch, moderate crowding in the lower arch, anterior crossbite and excessive gingival tissue on the labial surfaces of teeth in both the arches. The inadequate crown lengths made placement of the orthodontic brackets difficult. Preadjusted orthodontic brackets have a very precise placement protocol which can affect tooth movement in all 3 planes of space if violated. The periodontal condition was diagnosed as altered passive eruption Type IA. Interdisciplinary treatment protocols including periodontal surgical and orthodontic procedures were used. The periodontal surgical procedures were carried out prior to orthodontic therapy and the results obtained were satisfactory. It is suggested that orthodontists should be aware of conditions like altered passive eruption and modalities of management. In most instances, orthodontic therapy is not hindered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riegel, A; Klein, E; Tariq, M
Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before dailymore » image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.« less
Latent Learning in the Work Place: The Placement Experiences of Student-Coaches
ERIC Educational Resources Information Center
Gomes, Rúben; Jones, Robyn L.; Batista, Paula; Mesquita, Isabel
2018-01-01
The aim of this study was to investigate the work-based internship experiences of eight student-coaches. This was particularly in terms of what precisely such coaches learned within the practical context, and how they engaged with unexpected situational events. The methods employed within the project included focus group interviews and participant…
ERIC Educational Resources Information Center
Searl, Jeffrey P.
2003-01-01
Two studies were completed that focused on instrumentation and procedural issues associated with measurement of lingua-palatal contact pressure (LPCP) during speech. In the first experiment, physical features and response characteristics of 2 miniature pressure transducers (Entran EPI-BO and Precision Measurement 60S) were evaluated to identify a…
Chebroux, A; Leece, E A; Brearley, J C
2015-04-01
To evaluate animal comfort and ease of placement of a veterinary-specific intravenous catheter compared with a catheter manufactured for human use. Fifty-nine veterinary undergraduates were recruited to perform intravenous catheterisations with two brands of over-the-needle catheter [Smiths Medical Jelco® (human use) and Abbott Animal Health catheter® (veterinary use)] in 69 healthy cats (n = 28) and dogs (n = 41) requiring general anaesthesia. After a standardised pre-anaesthetic medication, each animal was randomly allocated to have one of the two brands of catheter placed. Each student was allowed a maximum of three attempts to achieve cephalic vein catheterisation. The student and a single experienced observer evaluated each attempt. Observations related to ease of placement and to the animal's reaction were recorded. Human use catheters were placed in 34 and veterinary use in 35 animals. There was no difference in weight, sex or sedation score between the two groups. The number of failed attempts was similar between the two groups. There was no difference between groups for the number of animals reacting to catheter insertion. The two types of catheters evaluated are equally suitable for intravenous catheterisation of sedated animals by veterinary undergraduate students. © 2015 British Small Animal Veterinary Association.
Electromagnetic navigation system for CT-guided biopsy of small lesions.
Appelbaum, Liat; Sosna, Jacob; Nissenbaum, Yizhak; Benshtein, Alexander; Goldberg, S Nahum
2011-05-01
The purpose of this study was to evaluate an electromagnetic navigation system for CT-guided biopsy of small lesions. Standardized CT anthropomorphic phantoms were biopsied by two attending radiologists. CT scans of the phantom and surface electromagnetic fiducial markers were imported into the memory of the 3D electromagnetic navigation system. Each radiologist assessed the accuracy of biopsy using electromagnetic navigation alone by targeting sets of nine lesions (size range, 8-14 mm; skin to target distance, 5.7-12.8 cm) under eight different conditions of detector field strength and orientation (n = 117). As a control, each radiologist also biopsied two sets of five targets using conventional CT-guided technique. Biopsy accuracy, number of needle passes, procedure time, and radiation dose were compared. Under optimal conditions (phantom perpendicular to the electromagnetic receiver at highest possible field strength), phantom accuracy to the center of the lesion was 2.6 ± 1.1 mm. This translated into hitting 84.4% (38/45) of targets in a single pass (1.1 ± 0.4 CT confirmations), which was significantly fewer than the 3.6 ± 1.3 CT checks required for conventional technique (p < 0.001). The mean targeting time was 38.8 ± 18.2 seconds per lesion. Including procedural planning (∼5.5 minutes) and final CT confirmation of placement (∼3.5 minutes), the full electromagnetic tracking procedure required significantly less time (551.6 ± 87.4 seconds [∼9 minutes]) than conventional CT (833.3 ± 283.8 seconds [∼14 minutes]) for successful targeting (p < 0.001). Less favorable conditions, including nonperpendicular relation between the axis of the machine and weaker field strength, resulted in statistically significant lower accuracy (3.7 ± 1 mm, p < 0.001). Nevertheless, first-pass biopsy accuracy was 58.3% (21/36) and second-pass (35/36) accuracy was 97.2%. Lesions farther from the skin than 20-25 cm were out of range for successful electromagnetic tracking. Virtual electromagnetic tracking appears to have high accuracy in needle placement, potentially reducing time and radiation exposure compared with those of conventional CT techniques in the biopsy of small lesions.
Zhang, Sheng; Su, Wanhan; Luo, Qiang; Chen, Bin
2014-01-01
This study is aimed at definition of the safe and dangerous zone for screw placement with Stoppa approach for rapid identification during operation and a new way for the studies on the “safe zone.” Pelvic CT data of 84 human subjects were recruited to reconstruct the three-dimensional (3D) models. The distances between the edges of the “safe zone,” “dangerous zone,” and specific anatomic landmarks such as the obturator canal and the pelvic brim were precisely measured, respectively. The results show that the absolute “dangerous zone” was from the pelvic brim to 3.07 cm below it and within 2.86 cm of the obturator canal, while the region 3.56 cm below the pelvic brim or 3.85 cm away from the obturator canal was the absolute “safe zone” for screw placement. The region between the absolute “safe zone” and the absolute “dangerous zone” was the relatively “dangerous zone.” As a conclusion, application of computer-assisted 3D modeling techniques aids in the precise measurement of “safe zone” and “dangerous zone” in combination with Stoppa incision. It was not recommended to place screws on the absolute dangerous zone, while, for the relatively “dangerous zone,” it depends on the individual variations in bony anatomy and the fracture type. PMID:24605328
Iqbal, Shams I; Molgaard, Christopher; Williamson, Christina; Flacke, Sebastian
2014-07-01
To evaluate the feasibility and efficacy of pneumothorax creation and chest tube insertion before computed tomography (CT)-guided coil localization of small peripheral lung nodules for video-assisted thoracoscopic surgical (VATS) wedge resection. From May 2011 to October 2013, 21 consecutive patients (seven men; mean age, 62 y; range, 42-76 y) scheduled for VATS wedge resection required CT-guided coil localization for small, likely nonpalpable peripheral lung lesions at a single institution. Outcomes were evaluated retrospectively for technical success and complications. There were 12 nodules and nine ground-glass opacities. Mean lesion distance from the pleural surface was 15 mm (range, 5-35 mm), and average size was 13 mm (range, 7-30 mm). A pneumothorax was successfully created in all patients with a Veress needle, and a chest tube was inserted. All target lesions were marked successfully, leaving one end of the coil within/beyond the lesion and the other end of the coil in the pleural space. The inserted chest tube was used to insufflate air to widen the pleural space during coil positioning and to aspirate any residual air before transfer of the patient to the operating room holding area. Intraparenchymal hemorrhages smaller than 7 cm in diameter developed in two patients during coil placement. All lesions were successfully resected with VATS. Histologic examinaiton revealed 13 primary adenocarcinomas, four metastases, and four benign lesions. Pneumothorax creation and chest tube placement before CT-guided coil localization of peripheral lung nodules for VATS wedge resection facilitates the deployment of the peripheral end of the coil in the pleural space and provides effective management of procedure-related pneumothorax until surgery. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Parra, Dimitri A; Chan, Melissa; Krishnamurthy, Ganesh; Spiegel, Lynn; Amaral, Joao G; Temple, Michael J; John, Philip R; Connolly, Bairbre L
2010-09-01
Juvenile idiopathic arthritis (JIA) has an incidence that ranges from 1 to 22 per 100,000 children worldwide, with involvement of the temporomandibular joint (TMJ) in 17-87% of patients. Intraarticular corticosteroid injections are beneficial in the local treatment of JIA and of other types of arthritis. To describe and assess the accuracy of an US-guided technique for visualization of needle placement within the TMJ in children. Between January 2000 and November 2007, 180 TMJ injections were performed during 116 encounters in 83 children with arthritis (71 girls, 12 boys; mean age 12.0 years). Access was obtained under sterile conditions using US guidance (linear 15-MHz or curvilinear 8-MHz transducers) in a coronal plane, and confirmed with CT. To minimize radiation, a limited focused CT protocol was developed. A bilateral injection was performed in 65 encounters (57%). Twenty-three children had repeat TMJ injections. All injections were performed using US guidance. CT confirmation was used in 127/180 TMJs (70%). In those confirmed with CT, the needle tip was intra-articular in 91% of cases. Triamcinolone hexacetonide was used in 92% of injections and triamcinolone acetonide in 8%. One major complication was encountered (skin atrophy at the injection site). In our experience, TMJ injections using sonographic guidance is a safe, effective and accurate procedure.
A semi-automated vascular access system for preclinical models
NASA Astrophysics Data System (ADS)
Berry-Pusey, B. N.; Chang, Y. C.; Prince, S. W.; Chu, K.; David, J.; Taschereau, R.; Silverman, R. W.; Williams, D.; Ladno, W.; Stout, D.; Tsao, T. C.; Chatziioannou, A.
2013-08-01
Murine models are used extensively in biological and translational research. For many of these studies it is necessary to access the vasculature for the injection of biologically active agents. Among the possible methods for accessing the mouse vasculature, tail vein injections are a routine but critical step for many experimental protocols. To perform successful tail vein injections, a high skill set and experience is required, leaving most scientists ill-suited to perform this task. This can lead to a high variability between injections, which can impact experimental results. To allow more scientists to perform tail vein injections and to decrease the variability between injections, a vascular access system (VAS) that semi-automatically inserts a needle into the tail vein of a mouse was developed. The VAS uses near infrared light, image processing techniques, computer controlled motors, and a pressure feedback system to insert the needle and to validate its proper placement within the vein. The VAS was tested by injecting a commonly used radiolabeled probe (FDG) into the tail veins of five mice. These mice were then imaged using micro-positron emission tomography to measure the percentage of the injected probe remaining in the tail. These studies showed that, on average, the VAS leaves 3.4% of the injected probe in the tail. With these preliminary results, the VAS system demonstrates the potential for improving the accuracy of tail vein injections in mice.
Optimising crime scene temperature collection for forensic entomology casework.
Hofer, Ines M J; Hart, Andrew J; Martín-Vega, Daniel; Hall, Martin J R
2017-01-01
The value of minimum post-mortem interval (minPMI) estimations in suspicious death investigations from insect evidence using temperature modelling is indisputable. In order to investigate the reliability of the collected temperature data used for modelling minPMI, it is necessary to study the effects of data logger location on the accuracy and precision of measurements. Digital data logging devices are the most commonly used temperature measuring devices in forensic entomology, however, the relationship between ambient temperatures (measured by loggers) and body temperatures has been little studied. The placement of loggers in this study in three locations (two outdoors, one indoors) had measurable effects when compared with actual body temperature measurements (simulated with pig heads), some more significant than others depending on season, exposure to the environment and logger location. Overall, the study demonstrated the complexity of the question of optimal logger placement at a crime scene and the potential impact of inaccurate temperature data on minPMI estimations, showing the importance of further research in this area and development of a standard protocol. Initial recommendations are provided for data logger placement (within a Stevenson Screen where practical), situations to avoid (e.g. placement of logger in front of windows when measuring indoor temperatures), and a baseline for further research into producing standard guidelines for logger placement, to increase the accuracy of minPMI estimations and, thereby, the reliability of forensic entomology evidence in court. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Abe, M.; Murata, Y.; Iinuma, H.; Ogitsu, T.; Saito, N.; Sasaki, K.; Mibe, T.; Nakayama, H.
2018-05-01
A magnetic field design method of magneto-motive force (coil block (CB) and iron yoke) placements for g - 2/EDM measurements has been developed and a candidate placements were designed under superconducting limitations of current density 125 A/mm2 and maximum magnetic field on CBs less than 5.5 T. Placements of CBs and an iron yoke with poles were determined by tuning SVD (singular value decomposition) eigenmode strengths. The SVD was applied on a response matrix from magneto-motive forces to the magnetic fields in the muon storage region and two-dimensional (2D) placements of magneto-motive forces were designed by tuning the magnetic field eigenmode strengths obtained by the magnetic field. The tuning was performed iteratively. Magnetic field ripples in the azimuthal direction were minimized for the design. The candidate magnetic design had five CBs and an iron yoke with center iron poles. The magnet satisfied specifications of homogeneity (0.2 ppm peak-to-peak in 2D placements (the cylindrical coordinate of the radial position R and axial position Z) and less than 1.0 ppm ripples in the ring muon storage volume (0.318 m < R < 0 . 348 m and -0.05 < Z < 0.05 m) with 3.0 T strength and a slightly negative BR (magnetic field radial component) at Z > 0.0 m) for the spiral muon injection from the iron yoke at top.
NASA Astrophysics Data System (ADS)
Stenzel, Roland; Lin, Ralph; Cheng, Peng; Kronreif, Gernot; Kornfeld, Martin; Lindisch, David; Wood, Bradford J.; Viswanathan, Anand; Cleary, Kevin
2007-03-01
Minimally invasive procedures are increasingly attractive to patients and medical personnel because they can reduce operative trauma, recovery times, and overall costs. However, during these procedures, the physician has a very limited view of the interventional field and the exact position of surgical instruments. We present an image-guided platform for precision placement of surgical instruments based upon a small four degree-of-freedom robot (B-RobII; ARC Seibersdorf Research GmbH, Vienna, Austria). This platform includes a custom instrument guide with an integrated spiral fiducial pattern as the robot's end-effector, and it uses intra-operative computed tomography (CT) to register the robot to the patient directly before the intervention. The physician can then use a graphical user interface (GUI) to select a path for percutaneous access, and the robot will automatically align the instrument guide along this path. Potential anatomical targets include the liver, kidney, prostate, and spine. This paper describes the robotic platform, workflow, software, and algorithms used by the system. To demonstrate the algorithmic accuracy and suitability of the custom instrument guide, we also present results from experiments as well as estimates of the maximum error between target and instrument tip.
Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riga, Celia V., E-mail: c.riga@imperial.ac.uk; Bicknell, Colin D.; Wallace, Daniel
2009-05-15
To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged formore » a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.« less
Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A
2008-08-01
Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.
Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth
2018-01-01
Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368
Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth
2018-03-01
Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haynsworth, R.F. Jr.; Noe, C.E.
A new percutaneous approach to sympathectomy using radiofrequency denervation has seemed to offer longer duration and less incidence of postsympathetic neuralgia as compared to phenol sympathetic blocks. To compare these techniques, 17 patients underwent either phenol lumbar sympathetic blocks (n = 9) or radiofrequency denervation (n = 8). Duration of sympathetic block was followed by a sweat test and temperature measurements. Results indicate that 89% of patients in the phenol group showed signs of sympathetic blockade after 8 weeks, as compared to 12% in the radiofrequency group (P less than 0.05). Although the incidence of post sympathetic neuralgia appears tomore » be less with radiofrequency denervation, further refinement of needle placement to ensure complete lesioning of the sympathetic chain will be required before the technique can offer advantages over current phenol techniques.« less
KommonBase - A precise direct bonding system for labial fixed appliances.
Miyashita, Wataru; Komori, Akira; Takemoto, Kyoto
2017-09-01
"KommonBase" is a system designed to customize the bracket base by means of an extended resin base covering the tooth. This system enables precise bracket placement and accurate fit on teeth. Moreover, KommonBase can be easily fabricated in a laboratory and bonded on each tooth using simple clinical procedures. Straight-wire treatment without wire bending was achieved in the clinical cases presented in this article using the KommonBase system for a labial fixed appliance. The application of KommonBase to the vestibular side enables efficient orthodontic treatment using simple mechanics. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.
Cepoiu-Martin, Monica; Tam-Tham, Helen; Patten, Scott; Maxwell, Colleen J; Hogan, David B
2016-11-01
The main objective of this study was to summarize the effects of various individual, caregiver, and system-related factors on the risk of long-term care (LTC) placement for persons with dementia. We searched electronic databases for longitudinal studies reporting on predictors of LTC placement for persons with dementia residing in the community or supportive care settings. We performed meta-analyses with hazard ratios (HRs) of various predictors using random effects models and stratified the HRs with several study variables. Data on predictors not included in the meta-analyses were summarized descriptively. Full-text reviews of 360 papers were performed with data from 37 papers used to calculate pooled HRs for LTC placement of select person with dementia (age, sex, race, marital status, type of dementia, living arrangement, and relationship to caregiver) and caregiver (age, sex, and depressive symptoms) characteristics. White race [HR = 1.67, 95% confidence intervals (CI): 1.41-1.99], greater dementia severity (HR = 1.05, 95% CI: 1.03-1.06), and older age (HR = 1.02, 95% CI: 1.01-1.03) increased the risk of LTC placement. Married persons with dementia (HR = 0.38, 95% CI: 0.16-0.86) and living with their caregiver (HR = 0.72, 95% CI: 0.56-0.92) had a lower risk. Behavioral and psychological symptoms of dementia, the degree of functional impairment, and caregiver burden had a consistent effect on the risk of LTC placement in our descriptive review. We quantified the predictive effect of several risk factors for LTC placement. These estimates could be used to more precisely categorize the risk of institutionalization and potentially link those at higher risk to appropriate services. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Thörmer, Gregor; Garnov, Nikita; Moche, Michael; Haase, Jürgen; Kahn, Thomas; Busse, Harald
2012-04-01
To determine whether a greatly reduced spatial resolution of fully reconstructed projection MR images can be used for the simultaneous 3D localization of multiple MR-visible markers and to assess the feasibility of a subsecond position tracking for clinical purposes. Miniature, inductively coupled RF coils were imaged in three orthogonal planes with a balanced steady-state free precession (SSFP) sequence and automatically localized using a two-dimensional template fitting and a subsequent three-dimensional (3D) matching of the coordinates. Precision, accuracy, speed and robustness of 3D localization were assessed for decreasing in-plane resolutions (0.6-4.7 mm). The feasibility of marker tracking was evaluated at the lowest resolution by following a robotically driven needle on a complex 3D trajectory. Average 3D precision and accuracy, sensitivity and specificity of localization ranged between 0.1 and 0.4 mm, 0.5 and 1.0 mm, 100% and 95%, and 100% and 96%, respectively. At the lowest resolution, imaging and localization took ≈350 ms and provided an accuracy of ≈1.0 mm. In the tracking experiment, the needle was clearly depicted on the oblique scan planes defined by the markers. Image-based marker localization at a greatly reduced spatial resolution is considered a feasible approach to monitor reference points or rigid instruments at subsecond update rates. Copyright © 2012 Elsevier Inc. All rights reserved.
Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade.
Fredrickson, Michael J; Ball, Craig M; Dalgleish, Adam J
2011-01-01
We investigated perineural catheter threading distance and orifice configuration during continuous interscalene analgesia. One hundred fifty-three patients receiving an anterolateral interscalene catheter (catheter needle and nerve/plexus in a similar alignment) for elective shoulder surgery were randomized to 1 of 3 groups: following out-of-plane ultrasound confirmation of the needle tip immediately lateral to the C5/6 roots, a nonstimulating catheter was blindly advanced 0.5 cm (end-hole; n = 50), 2.5 cm (multiorifice; n = 50) or 5 cm (multiorifice; n = 53) beyond the needle tip. Ropivacaine 0.75% + lidocaine 1% (50:50) 20 mL was administered preoperatively via the catheter before surgery under general anesthesia. A ropivacaine 0.2% 2 mL/hr elastomeric infusion with mandatory 6 hourly (and on demand) 5-mL boluses was continued for more than 48 hrs with tramadol available as rescue. Patients were questioned in the recovery room, at 24 and 48 hrs for numerical rating pain score (0-10), ropivacaine bolus, and tramadol consumption. Patients were more frequently pain-free in the recovery room in the multiorifice 2.5 and 5 cm groups compared with the end-hole 0.5 cm group (94%, 91% vs 66%; P < 0.001). During the first 24 hrs, the end-hole group demonstrated an earlier time to first pain (median, 10 vs17, 15 hrs; P < 0.001), higher "average pain" (median, 3 vs 1, 2, P = 0.004), and more ropivacaine bolus (median, 5 vs 3, 3; P < 0.001) and tramadol consumption (P = 0.01). Groups 2.5 and 5 cm did not significantly differ in any outcomes. These results suggest that multiorifice catheters provide superior intermittent bolus continuous peripheral nerve blockade compared with end-hole catheters. For anterolateral approach interscalene catheter placement, there is minimal benefit, either way, to 2.5- or 5-cm blind catheter advancement.
Cherkin, Daniel C.; Sherman, Karen J.; Avins, Andrew L.; Erro, Janet H.; Ichikawa, Laura; Barlow, William E.; Delaney, Kristin; Hawkes, Rene; Hamilton, Luisa; Pressman, Alice; Khalsa, Partap S.; Deyo, Richard A.
2009-01-01
Background Acupuncture is a popular complementary and alternative treatment for chronic back pain. Recent European trials suggest similar short-term benefits from real and sham acupuncture needling. This trial addresses the importance of needle placement and skin penetration in eliciting acupuncture effects for patients with chronic low back pain. Methods 638 adults with chronic mechanical low back pain were randomized to: individualized acupuncture, standardized acupuncture, simulated acupuncture, or usual care. Ten treatments were provided over 7 weeks by experienced acupuncturists. The primary outcomes were back-related dysfunction (Roland Disability score, range: 0 to 23) and symptom bothersomeness (0 to 10 scale). Outcomes were assessed at baseline and after 8, 26 and 52 weeks. Results At 8 weeks, mean dysfunction scores for the individualized, standardized, and simulated acupuncture groups improved by 4.4, 4.5, and 4.4 points, respectively, compared with 2.1 points for those receiving usual care (P<0.001). Participants receiving real or simulated acupuncture were more likely than those receiving usual care to experience clinically meaningful improvements on the dysfunction scale (60% vs. 39%, P<0.0001). Symptoms improved by 1.6 to 1.9 points in the treatment groups compared with 0.7 points in the usual care group (P<0.0001). After one year, participants in the treatment groups were more likely than those receiving usual care group to experience clinically meaningful improvements in dysfunction (59% to 65% versus 50%, respectively, P=0.02) but not in symptoms (P>0.05). Conclusions Although acupuncture was found effective for chronic low back pain, tailoring needling sites to each patient and penetration of the skin appear to be unimportant in eliciting therapeutic benefits. These findings raise questions about acupuncture’s purported mechanisms of action. It remains unclear whether acupuncture, or our simulated method of acupuncture, provide physiologically important stimulation or represent placebo or non-specific effects. PMID:19433697
Kelekis, Alexios; Filippiadis, Dimitrios K; Velonakis, Georgios; Martin, Jean-Baptist; Oikonomopoulos, Nikolaos; Brountzos, Elias; Kelekis, Nikolaos
2014-01-01
Transforaminal infiltrations in the cervical spine are governed by a higher rate of vascular puncture than in the lumbar spine. The purpose of our study is to assess the safety and efficacy of percutaneous, fluoroscopically guided nerve root infiltrations in cases of cervical radiculopathy. An indirect postero-lateral approach was performed through the ipsilateral facet joint. During the last 2 years, 25 patients experiencing cervical radiculopathy underwent percutaneous, fluoroscopically guided nerve root infiltrations by means of an indirect postero-lateral approach through the ipsilateral facet joint. The intra-articular position of the needle (22-gauge spinal needle) was fluoroscopically verified after injection of a small amount of contrast medium which also verified dispersion of the contrast medium periradicularly and in the epidural space. Then a mixture of long-acting glucocorticosteroid diluted in normal saline (1.5/1 mL) was injected intra-articularly. A questionnaire with a Numeric Visual Scale (NVS) scale helped assess pain relief, life quality, and mobility improvement. A mean of 2.3 sessions was performed in the patients of our study. In the vast majority of our patients 19/25 (76%), the second infiltration was performed within 7-10 days of the first one. Comparing the pain scores prior (mean value 8.80 ± 1.080 NVS units) and after (mean value 1.84 ± 1.405 NVS units), there was a mean decrease of 6.96 ± 1.695 NVS units [median value 7 NVS units (P < 0.001) in terms of pain reduction, effect upon mobility, and life quality. There were no clinically significant complications noted in our study. Fluoroscopically guided transforaminal infiltrations through the ipsilateral facet joint seem to be a feasible, efficacious, and safe approach for the treatment of patients with cervical radiculopathy. This approach facilitates needle placement and minimizes risk of complications.
Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G
2003-01-01
To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (p<0.001), and the 1-month CT volume was 43.6 cm(3) (p<0.001). The mean difference between the OR dose received by 90% of the prostate (D(90)) and the CT D(90) was 3.4% (95% confidence interval, 2.5-6.6%; p=0.034). The mean dose to 30% of the urethra was 120% of prescription in the OR and 138% on CT. The mean difference was 18% (95% confidence interval, 13-24%; p<0.001). Although small differences exist between the OR and CT dosimetry results, these data suggest that this intraoperative implant dosimetric representation system provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.
Artificial intelligence, physiological genomics, and precision medicine.
Williams, Anna Marie; Liu, Yong; Regner, Kevin R; Jotterand, Fabrice; Liu, Pengyuan; Liang, Mingyu
2018-04-01
Big data are a major driver in the development of precision medicine. Efficient analysis methods are needed to transform big data into clinically-actionable knowledge. To accomplish this, many researchers are turning toward machine learning (ML), an approach of artificial intelligence (AI) that utilizes modern algorithms to give computers the ability to learn. Much of the effort to advance ML for precision medicine has been focused on the development and implementation of algorithms and the generation of ever larger quantities of genomic sequence data and electronic health records. However, relevance and accuracy of the data are as important as quantity of data in the advancement of ML for precision medicine. For common diseases, physiological genomic readouts in disease-applicable tissues may be an effective surrogate to measure the effect of genetic and environmental factors and their interactions that underlie disease development and progression. Disease-applicable tissue may be difficult to obtain, but there are important exceptions such as kidney needle biopsy specimens. As AI continues to advance, new analytical approaches, including those that go beyond data correlation, need to be developed and ethical issues of AI need to be addressed. Physiological genomic readouts in disease-relevant tissues, combined with advanced AI, can be a powerful approach for precision medicine for common diseases.
Rosenfeld, Alan L; Mandelaris, George A; Tardieu, Philippe B
2006-08-01
The purpose of this paper is to expand on part 1 of this series (published in the previous issue) regarding the emerging future of computer-guided implant dentistry. This article will introduce the concept of rapid-prototype medical modeling as well as describe the utilization and fabrication of computer-generated surgical drilling guides used during implant surgery. The placement of dental implants has traditionally been an intuitive process, whereby the surgeon relies on mental navigation to achieve optimal implant positioning. Through rapid-prototype medical modeling and the ste-reolithographic process, surgical drilling guides (eg, SurgiGuide) can be created. These guides are generated from a surgical implant plan created with a computer software system that incorporates all relevant prosthetic information from which the surgical plan is developed. The utilization of computer-generated planning and stereolithographically generated surgical drilling guides embraces the concept of collaborative accountability and supersedes traditional mental navigation on all levels of implant therapy.
Contamination Study of Micro Pulsed Plasma Thruster
2008-03-01
missions ranging from nano -satellites to large spacecrafts requiring precision placement1. As an unfortunate side effect, the exhaust plume induces...the electrodes9. The electrodes have often been arranged coaxially . The system consists of electrodes, capacitors as energy storage units, a spark...increasing interest in the so-called micro- and nano -satellites, which are highly maneuverable and have lower cost. These small satellites are aimed to
Design and development of a work robot to place ATLAS SCT modules onto barrel cylinders
NASA Astrophysics Data System (ADS)
Terada, S.; Kobayashi, H.; Sengoku, H.; Kato, Y.; Hara, K.; Honma, F.; Ikegami, Y.; Iwata, Y.; Kohriki, T.; Kondo, T.; Nakano, I.; Takashima, R.; Tanaka, R.; Ujiie, N.; Unno, Y.; Yasuda, S.
2005-04-01
More than 2000 silicon modules need to be placed and fastened on the ATLAS SCT barrel tracker. A semi-automatic pick-and-place work robot was designed and developed to cope with the module placement for the SCT barrel assembly. We found that this robot could place modules to a mechanical precision of better than 25 μm.
ColorMoves: Optimizing Color's Potential for Exploration and Communication of Data
NASA Astrophysics Data System (ADS)
Samsel, F.
2017-12-01
Color is the most powerful perceptual channel available for exposing and communicating data. Most visualizations are rendered in one of a handful of common colormaps - the rainbow, cool-warm, heat map and viridis. These maps meet the basic criteria for encoding data - perceptual uniformity and reasonable discriminatory power. However, as the size and complexity of data grows, our need to optimize the potential of color grows. The ability to expose greater detail and differentiate between multiple variables becomes ever more important. To meet this need we have created ColorMoves, an interactive colormap construction tool that enables scientists to quickly and easily align a concentration contrast with the data ranges of interest. Perceptual research tells us that luminance is the strongest contrast and thus provides the highest degree of perceptual discrimination. However, the most commonly used colormaps contain a limited range of luminance contrast. ColorMoves enables interactive constructing colormaps enabling one to distribute the luminance where is it most needed. The interactive interface enables optimal placement of the color scales. The ability to watch the changes on ones data, in real time makes precision adjustment quick and easy. By enabling more precise placement and multiple ranges of luminance one can construct colomaps containing greater discriminatory power. By selecting from the wide range of color scale hues scientists can create colormaps intuitive to their subject. ColorMoves is comprised of four main components: a set of 40 color scales; a histogram of the data distribution; a viewing area showing the colormap on your data; and the controls section. The 40 color scales span the spectrum of hues, saturation levels and value distributions. The histogram of the data distribution enables placement of the color scales in precise locations. The viewing area show is the impact of changes on the data in real time. The controls section enables export of the constructed colormaps for use in tools such as ParaView and Matplotlib. For a clearer understanding of ColorMoves capability we recommend trying it out at SciVisColor.org.
Assessment of clinical application of pulse oximetry probes in llamas and alpacas.
Grubb, Tamara L; Anderson, David E
2017-08-01
The placement and accuracy of pulse oximeter probes can vary markedly among species. For our study, we aimed to assess the accuracy of pulse oximetry and to determine the most clinically useful sites for probe placement in llamas and alpacas. The objectives included an analysis of pulse oximetry probes for accurate assessment of llamas and alpacas and to determine the best placement of the probes to achieve accurate readings. For study 1, saturation of haemoglobin with oxygen was measured in 184 arterial blood gas samples (SaO 2 ) using a co-oximeter and compared to saturation of haemoglobin with oxygen simultaneously measured using a pulse oximeter (S p O 2 ). The bias and precision for the SpO 2 -S a O 2 difference was calculated and plotted on a Bland-Altman plot. For study 2, S p O 2 data was collected 624 times from a variety of sites [tongue (T), nasal septum (NS), lip (L), vulva (V), prepuce (P), ear (E), and scrotum (S)] and recorded based upon a percentage of successful readings. Results for study 1 revealed that S p O 2 was consistently 0 to -6% points different than S a O 2 . The bias and precision of the S p O 2 -S a O 2 difference was -2.6 ± 1.7%. Results for study 2 uncovered that 540 recordings were successful readings and were obtained from the tongue and nasal septum with 97% accuracy, the lip 80%, vulva 62%, prepuce 59%, ear and scrotum < 50%. We concluded that pulse oximetry probes provide reliable estimates of arterial haemoglobin oxygen saturation in llamas and alpacas and is most accurately read when placed on the nasal septum or tongue.
Walsh, M.G.; Bjorgo, K.A.; Isely, J.J.
2000-01-01
To determine the effects of surgical implantation method and temperature on mortality and transmitter loss, we compared two antenna placements (trailing antenna versus shielded needle) and two suture materials (absorbable versus nonabsorbable) in hybrid striped bass Morone saxitilis x Morone chrysops (227-410 mm total length) that had been surgically implanted with simulated transmitters and held at high (22-29??C) and low (12-18??C) temperatures for 120 d. Fish were individually examined after 7, 30, 60. 90. and 120 d to evaluate suture and wound condition as well as transmitter loss. Neither suture material nor antenna placement affected transmitter loss, mortality, or growth at either high or low temperatures. Absorbable sutures were lost more quickly than were nonabsorbable sutures, but they persisted beyond incision closure at both high and low temperatures. At high temperatures, 50% suture loss occurred by 30 d for absorbable sutures and by 60 d for nonabsorbable sutures. Mortality occurred only at high temperatures but was delayed and was likely caused by peritoneal infection. Transmitter loss was not significant; it occurred only in the low-temperature trial and was caused by pressure necrosis at the incision rather than by suture failure. Temperature significantly affected all responses examined in this study. Significant irritation, infection, and mortality occurred in all treatment groups at high temperatures.
NASA Astrophysics Data System (ADS)
Milliere, Laure; Verrecchia, Eric; Gussone, Nikolaus
2014-05-01
Calcium (Ca), carbon (C) and oxygen (O) are important elements in terrestrial environment, as their biogeochemical cycles are directly related to the storage of atmospheric carbon. Nevertheless, contrarily to C and O, Ca isotope composition has been only poorly studied in the terrestrial carbonates. Needle Fibre Calcite (NFC) is one of the most common pedogenic carbonates, unless its origin is still under debate. Recent studies explain its formation by precipitation inside fungal hyphae. Due to this possible biogenic origin, NFC can be considered as a potential bridge between the biochemistry (precipitation inside organic structure) and geochemistry (pedogenic carbonate related to soil conditions) of the Ca. Thus, the study of the Ca isotope composition of NFC seem to be of first interest in order to shed light on the behaviour of Ca in terrestrial environment, especially when precipitation of secondary carbonates is involved. The sampling site is situated in the Swiss Jura Mountains and has been chosen due to a previous complete study of the C and O isotope composition of NFC in relation to the ecosystem, which represent a good precondition for the understanding of the NFC Ca isotope signatures in this context. In this study, the implication of the fungi in the origin of NFC is investigated, by comparing the Ca isotope composition of NFC and a purely physicochemical calcite cement (LCC), both precipitated in the same environment. The δ44Ca signature of NFC and LCC crystals were used to determine possible differences of the precipitation rate during their formation. NFC and LCC have similar δ18O composition and are supposed to precipitate at the same temperature (Milliere et al., 2011a). Thus the study of Ca isotope composition of NFC seems to demonstrate that the elongated shape of the calcite needle can be explained by different precipitation processes than the rhombohedric calcite crystals precipitated in the same environment; and more precisely, the specific shape of NFC could be ascribed to a growth related to fungal organic molecules or potentially inside fungal hyphae. Three microscopic morphologies of NFC, previously defined (Milliere et al., 2011a), have been also examined in order to trace the evolution of the NFC inside the soil porosity. The Ca isotope composition of the simple needles, which are supposed to be the original form of NFC are the less fractionated compared to the soil solution, whereas the Ca isotope composition of the two other microscopic morphologies, namely the simple needle with nanofibres and the simple needle with overgrowths, are more fractionated, like the LCC, indicating potentially the influence of biogenic processes in the formation of the simple needles. Milliere L, Hasinger O, Bindschedler S, Cailleau G, Spangenberg JE, Verrecchia EP. 2011a. Stable carbon and oxygen isotopic signatures of pedogenic needle fibre calcite. Geoderma 161, 74-87.
"MRI Stealth" robot for prostate interventions.
Stoianovici, Dan; Song, Danny; Petrisor, Doru; Ursu, Daniel; Mazilu, Dumitru; Muntener, Michael; Mutener, Michael; Schar, Michael; Patriciu, Alexandru
2007-01-01
The paper reports an important achievement in MRI instrumentation, a pneumatic, fully actuated robot located within the scanner alongside the patient and operating under remote control based on the images. Previous MRI robots commonly used piezoelectric actuation limiting their compatibility. Pneumatics is an ideal choice for MRI compatibility because it is decoupled from electromagnetism, but pneumatic actuators were hardly controllable. This achievement was possible due to a recent technology breakthrough, the invention of a new type of pneumatic motor, PneuStep 1, designed for the robot reported here with uncompromised MRI compatibility, high-precision, and medical safety. MrBot is one of the "MRI stealth" robots today (the second is described in this issue by Zangos et al.). Both of these systems are also multi-imager compatible, being able to operate with the imager of choice or cross-imaging modalities. For MRI compatibility the robot is exclusively constructed of nonmagnetic and dielectric materials such as plastics, ceramics, crystals, rubbers and is electricity free. Light-based encoding is used for feedback, so that all electric components are distally located outside the imager's room. MRI robots are modern, digital medical instruments in line with advanced imaging equipment and methods. These allow for accessing patients within closed bore scanners and performing interventions under direct (in scanner) imaging feedback. MRI robots could allow e.g. to biopsy small lesions imaged with cutting edge cancer imaging methods, or precisely deploy localized therapy at cancer foci. Our robot is the first to show the feasibility of fully automated in-scanner interventions. It is customized for the prostate and operates transperineally for needle interventions. It can accommodate various needle drivers for different percutaneous procedures such as biopsy, thermal ablations, or brachytherapy. The first needle driver is customized for fully automated low-dose radiation seed brachytherapy. This paper gives an introduction to the challenges of MRI robot compatibility and presents the solutions adopted in making the MrBot. Its multi-imager compatibility and other preclinical tests are included. The robot shows the technical feasibility of MRI-guided prostate interventions, yet its clinical utility is still to be determined.
“MRI Stealth” robot for prostate interventions
STOIANOVICI, DAN; SONG, DANNY; PETRISOR, DORU; URSU, DANIEL; MAZILU, DUMITRU; MUTENER, MICHAEL; SCHAR, MICHAEL; PATRICIU, ALEXANDRU
2011-01-01
The paper reports an important achievement in MRI instrumentation, a pneumatic, fully actuated robot located within the scanner alongside the patient and operating under remote control based on the images. Previous MRI robots commonly used piezoelectric actuation limiting their compatibility. Pneumatics is an ideal choice for MRI compatibility because it is decoupled from electromagnetism, but pneumatic actuators were hardly controllable. This achievement was possible due to a recent technology breakthrough, the invention of a new type of pneumatic motor, PneuStep (1), designed for the robot reported here with uncompromised MRI compatibility, high-precision, and medical safety. MrBot is one of the “MRI stealth” robots today (the second is described in this issue by Zangos et al.). Both of these systems are also multi-imager compatible, being able to operate with the imager of choice or cross-imaging modalities. For MRI compatibility the robot is exclusively constructed of nonmagnetic and dielectric materials such as plastics, ceramics, crystals, rubbers and is electricity free. Light-based encoding is used for feedback, so that all electric components are distally located outside the imager’s room. MRI robots are modern, digital medical instruments in line with advanced imaging equipment and methods. These allow for accessing patients within closed bore scanners and performing interventions under direct (in scanner) imaging feedback. MRI robots could allow e.g. to biopsy small lesions imaged with cutting edge cancer imaging methods, or precisely deploy localized therapy at cancer foci. Our robot is the first to show the feasibility of fully automated in-scanner interventions. It is customized for the prostate and operates transperineally for needle interventions. It can accommodate various needle drivers for different percutaneous procedures such as biopsy, thermal ablations, or brachytherapy. The first needle driver is customized for fully automated low-dose radiation seed brachytherapy. This paper gives an introduction to the challenges of MRI robot compatibility and presents the solutions adopted in making the MrBot. Its multi-imager compatibility and other preclinical tests are included. The robot shows the technical feasibility of MRI-guided prostate interventions, yet its clinical utility is still to be determined. PMID:17763098
... needle biopsy procedures include fine-needle aspiration and core needle biopsy. Needle biopsy may be used to ... hollow needle to draw cells from your body. Core needle biopsy. This type of needle biopsy uses ...
Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas
2017-06-01
Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.
Breast abscess: evidence based management recommendations.
Lam, Elaine; Chan, Tiffany; Wiseman, Sam M
2014-07-01
Literature review was carried out and studies reporting on treatment of breast abscesses were critically appraised for quality and their level of evidence using the Strength of Recommendation Taxonomy guidelines, and key recommendations were summarized. Needle aspiration either with or without ultrasound guidance should be employed as first line treatment of breast abscesses. This approach has the potential benefits of: superior cosmesis, shorter healing time, and avoidance of general anaesthesia. Multiple aspiration sessions may be required for cure. Ultrasound-guided percutaneous catheter placement may be considered as an alternative approach for treatment of larger abscesses (>3 cm). Surgical incision and drainage should be considered for first line therapy in large (>5 cm), multiloculated, or long standing abscesses, or if percutaneous drainage is unsuccessful. All patients should be treated concurrently with antibiotics. Patients with recurrent subareolar abscesses and fistulas should be referred for consideration of surgical treatment.
Diamond Shaped Ring Laser Characterization, Package Design and Performance
2006-09-01
fabricated by Binoptics, with the end facets formed by chemically assisted ion beam etching . The lasers, designed for operation at 1550 nm, propagated bi...calculated and Corning OptiFocus™ Lensed fiber was chosen to use for the four fiber outputs. Each fiber placement was actively optimized. Output power...aligned using active feedback and placed with submicron precision. The prototype package design was constrained to modification of a prior
Adequacy of Si:P chains as Fermi-Hubbard simulators
NASA Astrophysics Data System (ADS)
Dusko, Amintor; Delgado, Alain; Saraiva, André; Koiller, Belita
2018-01-01
The challenge of simulating many-body models with analogue physical systems requires both experimental precision and very low operational temperatures. Atomically precise placement of dopants in Si permits the construction of nanowires by design. We investigate the suitability of these interacting electron systems as simulators of a fermionic extended Hubbard model on demand. We describe the single-particle wavefunctions as a linear combination of dopant orbitals (LCDO). The electronic states are calculated within configuration interaction (CI). Due to the peculiar oscillatory behavior of each basis orbital, properties of these chains are strongly affected by the interdonor distance R0, in a non-monotonic way. Ground state (T = 0 K) properties such as charge and spin correlations are shown to remain robust under temperatures up to 4 K for specific values of R0. The robustness of the model against disorder is also tested, allowing some fluctuation of the placement site around the target position. We suggest that finite donor chains in Si may serve as an analog simulator for strongly correlated model Hamiltonians. This simulator is, in many ways, complementary to those based on cold atoms in optical lattices—the trade-off between the tunability achievable in the latter and the survival of correlation at higher operation temperatures for the former suggests that both technologies are applicable for different regimes.
High-Repeatability, Robot Friendly, ORU Interface
NASA Technical Reports Server (NTRS)
Voellmer, George M. (Inventor)
1992-01-01
A robot-friendly coupling device for an Orbital Replacement Unit (ORU). The invention will provide a coupling that is detached and attached remotely by a robot. The design of the coupling must allow for slight misalignments, over torque protection, and precision placement. This is accomplished by using of a triangular interface having three components. A base plate assembly is located on an attachment surface, such as a satellite. The base plate assembly has a cup member, a slotted member, and a post member. The ORU that the robot attaches to the base plate assembly has an ORU plate assembly with two cone members and a post member which mate to the base plate assembly. As the two plates approach one another, one cone member of the ORU plate assembly only has to be placed accurately enough to fall into the cup member of the base plate assembly. The cup forces alignment until a second cone falls into a slotted member which provides final alignment. A single bolt is used to attach the two plates. Two deflecting plates are attached to the backs of the plates. When pressure is applied to the center of the deflecting plates, the force is distributed preventing the ORU & base plates from deflecting. This accounts for precision in the placement of the article.
Novel 3-D laparoscopic magnetic ultrasound image guidance for lesion targeting
Sindram, David; McKillop, Iain H; Martinie, John B; Iannitti, David A
2010-01-01
Objectives: Accurate laparoscopic liver lesion targeting for biopsy or ablation depends on the ability to merge laparoscopic and ultrasound images with proprioceptive instrument positioning, a skill that can be acquired only through extensive experience. The aim of this study was to determine whether using magnetic positional tracking to provide three-dimensional, real-time guidance improves accuracy during laparoscopic needle placement. Methods: Magnetic sensors were embedded into a needle and laparoscopic ultrasound transducer. These sensors interrupted the magnetic fields produced by an electromagnetic field generator, allowing for real-time, 3-D guidance on a stereoscopic monitor. Targets measuring 5 mm were embedded 3–5 cm deep in agar and placed inside a laparoscopic trainer box. Two novices (a college student and an intern) and two experts (hepatopancreatobiliary surgeons) targeted the lesions out of the ultrasound plane using either traditional or 3-D guidance. Results: Each subject targeted 22 lesions, 11 with traditional and 11 with the novel guidance (n = 88). Hit rates of 32% (14/44) and 100% (44/44) were observed with the traditional approach and the 3-D magnetic guidance approach, respectively. The novices were essentially unable to hit the targets using the traditional approach, but did not miss using the novel system. The hit rate of experts improved from 59% (13/22) to 100% (22/22) (P < 0.0001). Conclusions: The novel magnetic 3-D laparoscopic ultrasound guidance results in perfect targeting of 5-mm lesions, even by surgical novices. PMID:21083797
Instrument-mounted displays for reducing cognitive load during surgical navigation.
Herrlich, Marc; Tavakol, Parnian; Black, David; Wenig, Dirk; Rieder, Christian; Malaka, Rainer; Kikinis, Ron
2017-09-01
Surgical navigation systems rely on a monitor placed in the operating room to relay information. Optimal monitor placement can be challenging in crowded rooms, and it is often not possible to place the monitor directly beside the situs. The operator must split attention between the navigation system and the situs. We present an approach for needle-based interventions to provide navigational feedback directly on the instrument and close to the situs by mounting a small display onto the needle. By mounting a small and lightweight smartwatch display directly onto the instrument, we are able to provide navigational guidance close to the situs and directly in the operator's field of view, thereby reducing the need to switch the focus of view between the situs and the navigation system. We devise a specific variant of the established crosshair metaphor suitable for the very limited screen space. We conduct an empirical user study comparing our approach to using a monitor and a combination of both. Results from the empirical user study show significant benefits for cognitive load, user preference, and general usability for the instrument-mounted display, while achieving the same level of performance in terms of time and accuracy compared to using a monitor. We successfully demonstrate the feasibility of our approach and potential benefits. With ongoing technological advancements, instrument-mounted displays might complement standard monitor setups for surgical navigation in order to lower cognitive demands and for improved usability of such systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuan, S; Lu, WG; Chen, YP
2015-03-11
A unique strategy, sequential linker installation (SLI), has been developed to construct multivariate MOFs with functional groups precisely positioned. PCN-700, a Zr-MOF with eight-connected Zr6O4(OH)(8)(H2O)(4) clusters, has been judiciously designed; the Zr-6 clusters in this MOF are arranged in such a fashion that, by replacement of terminal OH-/H2O ligands, subsequent insertion of linear dicarboxylate linkers is achieved. We demonstrate that linkers with distinct lengths and functionalities can be sequentially installed into PCN-700. Single-crystal to single-crystal transformation is realized so that the positions of the subsequently installed linkers are pinpointed via single-crystal X-ray diffraction analyses. This methodology provides a powerful toolmore » to construct multivariate MOFs with precisely positioned functionalities in the desired proximity, which would otherwise be difficult to achieve.« less
Precise frequency calibration using television video carriers
NASA Technical Reports Server (NTRS)
Burkhardt, Edward E.
1990-01-01
The availability of inexpensive and quick precise frequency calibration methods is limited. VLF and GPS do offer precise calibration. However, antenna placement, cost of equipment, and calibration time place many restrictions on the user. The USNO maintained line-10 television Time of Coincidence (TOC) of station WTTG, channel 5, Washington, DC requires a frequency stable video carrier. This video carrier, 77.24 MHz is controlled by the same cesium beam standard controlling the TOC of line-10. Excellent frequency comparisons against this video carrier have been accomplished at 95 miles (153 km). With stable propagation and a three foot wire antenna, a part in 10(exp 9) can be determined in a few minutes. Inexpensive field equipment with a synthesized 1 kHz offset from the video carrier offers parts in 10(exp 11) calibrations in a few minutes using an oscilloscope as a phase comparator.
Precise frequency calibration using television video carriers
NASA Astrophysics Data System (ADS)
Burkhardt, Edward E.
1990-05-01
The availability of inexpensive and quick precise frequency calibration methods is limited. VLF and GPS do offer precise calibration. However, antenna placement, cost of equipment, and calibration time place many restrictions on the user. The USNO maintained line-10 television Time of Coincidence (TOC) of station WTTG, channel 5, Washington, DC requires a frequency stable video carrier. This video carrier, 77.24 MHz is controlled by the same cesium beam standard controlling the TOC of line-10. Excellent frequency comparisons against this video carrier have been accomplished at 95 miles (153 km). With stable propagation and a three foot wire antenna, a part in 10(exp 9) can be determined in a few minutes. Inexpensive field equipment with a synthesized 1 kHz offset from the video carrier offers parts in 10(exp 11) calibrations in a few minutes using an oscilloscope as a phase comparator.
Nagarajah, James; Sheu-Grabellus, Sien-Yi; Farahati, Jamshid; Kamruddin, Kamer A; Bockisch, Andreas; Schmid, Kurt Werner; Görges, Rainer
2012-07-01
Fine-needle aspiration biopsy (FNAB) is a simple technique for the investigation of suspicious thyroid nodules. However, low success rates are reported in the literature. The aim of this prospective study was to compare the clinical performance and impact of an automatic aspirator, referred to here as Aspirator 3, to those of the manual technique for the FNAB of clinically suspicious thyroid nodules. One hundred nine consecutive patients with 121 clinically suspicious thyroid nodules underwent a biopsy twice of the same site with the clinically approved Aspirator 3 and with the manual technique. The number of follicular cell formations and the total number of follicular cells in the aspirate were counted using the ThinPrep® method. With the Aspirator 3, the total number and the mean number of extracted cell formations were significantly higher than the values achieved with the manual technique (total: 3222 vs. 1951, p=0.02; mean: 27 vs. 16). The total number of cells that were biopsied was also higher when the Aspirator 3 was utilized (47,480 vs. 23,080, p=0.005). Overall, the Aspirator 3 was superior in 65 biopsies, and the manual technique was superior in 39 biopsies. In terms of cell formations and the total number of cells aspirated, the Aspirator 3 was superior to the manual technique. Further, the Aspirator 3 was more convenient to use and had a greater precision in needle guidance.
Dray, Xavier; Donatelli, Gianfranco; Krishnamurty, Devi Mukkai; Dubcenco, Elena; Wroblewski, Ronald J; Assumpcao, Lia; Giday, Samuel A; Buscaglia, Jonathan M; Shin, Eun J; Magno, Priscilla; Pipitone, Laurie J; Marohn, Michael R; Kantsevoy, Sergey V; Kalloo, Anthony N
2010-09-01
Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.
Reviewing the Utility of EUS FNA to Advance Precision Medicine in Pancreatic Cancer
Berry, William; Lundy, Joanne; Croagh, Daniel; Jenkins, Brendan J.
2018-01-01
Advanced pancreatic cancer (PC) is an aggressive malignancy with few effective therapeutic options. While the evolution of precision medicine in recent decades has changed the treatment landscape in many cancers, at present no targeted therapies are used in the routine management of PC. Only a minority of patients with PC present with surgically resectable disease, and in the remainder obtaining high quality biopsy material for both diagnosis and molecular testing can prove challenging. Endoscopic ultrasound-guided fine needle aspiration (EUS FNA) is a widely used diagnostic procedure in PC, and allows tumour sampling in patients with both early and late stage disease. This review will provide an update on the role of EUS FNA as a diagnostic tool, as well as a source of genetic material which can be used both for molecular analysis and for the creation of valuable preclinical disease models. We will also consider relevant clinical applications of EUS FNA in the management of PC, and the path towards bringing precision medicine closer to the clinic in this challenging disease. PMID:29382047
NASA Astrophysics Data System (ADS)
Demers, Jean-Philippe; Habenstein, Birgit; Loquet, Antoine; Kumar Vasa, Suresh; Giller, Karin; Becker, Stefan; Baker, David; Lange, Adam; Sgourakis, Nikolaos G.
2014-09-01
We introduce a general hybrid approach for determining the structures of supramolecular assemblies. Cryo-electron microscopy (cryo-EM) data define the overall envelope of the assembly and rigid-body orientation of the subunits while solid-state nuclear magnetic resonance (ssNMR) chemical shifts and distance constraints define the local secondary structure, protein fold and inter-subunit interactions. Finally, Rosetta structure calculations provide a general framework to integrate the different sources of structural information. Combining a 7.7-Å cryo-EM density map and 996 ssNMR distance constraints, the structure of the type-III secretion system needle of Shigella flexneri is determined to a precision of 0.4 Å. The calculated structures are cross-validated using an independent data set of 691 ssNMR constraints and scanning transmission electron microscopy measurements. The hybrid model resolves the conformation of the non-conserved N terminus, which occupies a protrusion in the cryo-EM density, and reveals conserved pore residues forming a continuous pattern of electrostatic interactions, thereby suggesting a mechanism for effector protein translocation.
BiopSee® - transperineal stereotactic navigated prostate biopsy.
Zogal, Pawel; Sakas, Georgios; Rösch, Woerner; Baltas, Dimos
2011-06-01
In the recent years, prostate cancer was the most commonly diagnosed cancer in men. Currently secure diagnosis confirmation is done by a transrectal biopsy and following histopathological examination. Conventional transrectal biopsy success rates are rather low with ca. 30% detection upon the first and ca 20% after re-biopsy. The paper presents a novel system for stereotactic navigated prostate biopsy. The approach results into higher accuracy, reproducibility and unrestricted and effective access to all prostate regions. Custom designed ultrasound, new template design and integrated 2-axes stepper allows superior 2D and 3D prostate imaging quality and precise needle navigation. DICOM functionality and image fusion enable to import pre-operative datasets (e.g. multiparametric MRI, targets etc.) and overlay all available radiological information into the biopsy planning and guiding procedure. The biopsy needle insertion itself is performed under augmented reality ultrasound guidance. Each procedure step is automatically documented in order to provide quality assurance and permit data re-usage for the further treatment. First clinical results indicates success rates of ca. 70% by first biopsies by our approach.
Hollow mandrin facilitates external ventricular drainage placement.
Heese, O; Regelsberger, J; Kehler, U; Westphal, M
2005-07-01
Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.
Advanced EUS Guided Tissue Acquisition Methods for Pancreatic Cancer
Kandel, Pujan; Wallace, Michael B.
2018-01-01
Pancreas cancer is a lethal cancer as the majority patients are diagnosed at an advanced incurable stage. Despite improvements in diagnostic modalities and management strategies, including surgery and chemotherapies, the outcome of pancreas cancer remains poor. Endoscopic ultrasound (EUS) is an important imaging tool for pancreas cancer. For decades, resected pancreas cancer and other cancer specimens have been used to identify tissue biomarkers or genomics for precision therapy; however, only 20% of patients undergo surgery, and thus, this framework is not useful for unresectable pancreas cancer. With advancements in needle technologies, tumor specimens can be obtained at the time of tissue diagnosis. Tumor tissue can be used for development of personalized cancer treatment, such as performing whole exome sequencing and global genomic profiling of pancreas cancer, development of tissue biomarkers, and targeted mutational assays for precise chemotherapy treatment. In this review, we discuss the recent advances in tissue acquisition of pancreas cancer. PMID:29463004
NASA Astrophysics Data System (ADS)
Goudarzi, H.; Dousti, M. J.; Shafaei, A.; Pedram, M.
2014-05-01
This paper presents a physical mapping tool for quantum circuits, which generates the optimal universal logic block (ULB) that can, on average, perform any logical fault-tolerant (FT) quantum operations with the minimum latency. The operation scheduling, placement, and qubit routing problems tackled by the quantum physical mapper are highly dependent on one another. More precisely, the scheduling solution affects the quality of the achievable placement solution due to resource pressures that may be created as a result of operation scheduling, whereas the operation placement and qubit routing solutions influence the scheduling solution due to resulting distances between predecessor and current operations, which in turn determines routing latencies. The proposed flow for the quantum physical mapper captures these dependencies by applying (1) a loose scheduling step, which transforms an initial quantum data flow graph into one that explicitly captures the no-cloning theorem of the quantum computing and then performs instruction scheduling based on a modified force-directed scheduling approach to minimize the resource contention and quantum circuit latency, (2) a placement step, which uses timing-driven instruction placement to minimize the approximate routing latencies while making iterative calls to the aforesaid force-directed scheduler to correct scheduling levels of quantum operations as needed, and (3) a routing step that finds dynamic values of routing latencies for the qubits. In addition to the quantum physical mapper, an approach is presented to determine the single best ULB size for a target quantum circuit by examining the latency of different FT quantum operations mapped onto different ULB sizes and using information about the occurrence frequency of operations on critical paths of the target quantum algorithm to weigh these latencies. Experimental results show an average latency reduction of about 40 % compared to previous work.
Portal placement in elbow arthroscopy by novice surgeons: cadaver study.
Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N
2017-07-01
In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p < 0.001), the lateral antebrachial cutaneous nerve (4.0 mm, p < 0.001), and the radial nerve (25 mm, p < 0.001) was different from the average reported distances in the literature. A difference was found between the distance of the anterolateral portal and the PABCN (32 mm, p < 0.001) compared to previous studies. Three major iatrogenic complications were observed, including: laceration of the posterior bundle of the medial ulnar collateral ligament, lateral ulnar collateral ligament midsubstance laceration, and median nerve partial laceration. Surgeons increasingly consider arthroscopic treatment as an option for elbow pathology. In the present study a surgical complication rate of 30 % was found with novice portal placement during elbow arthroscopy. Furthermore, as the results from this study have indicated, accurate, precise, and safe portal placement in elbow arthroscopy is not easily achieved by didactic lecture and cadaver instruction session alone. Level of evidence V.
Schulman, Allison R; Thompson, Christopher C; Odze, Robert; Chan, Walter W; Ryou, Marvin
2017-02-01
EUS-guided liver biopsy sampling using FNA and, more recently, fine-needle biopsy (FNB) needles has been reported with discrepant diagnostic accuracy, in part due to differences in methodology. We aimed to compare liver histologic yields of 4 EUS-based needles and 2 percutaneous needles to identify optimal number of needle passes and suction. Six needle types were tested on human cadaveric tissue: one 19G FNA needle, one existing 19G FNB needle, one novel 19G FNB needle, one 22G FNB needle, and two 18G percutaneous needles (18G1 and 18G2). Two needle excursion patterns (1 vs 3 fanning passes) were performed on all EUS needles. Primary outcome was number of portal tracts. Secondary outcomes were degree of fragmentation and specimen adequacy. Pairwise comparisons were performed using t tests, with a 2-sided P < .05 considered to be significant. Multivariable regression analysis was performed. In total, 288 liver biopsy samplings (48 per needle type) were performed. The novel 19G FNB needle had significantly increased mean portal tracts compared with all needle types. The 22G FNB needle had significantly increased portal tracts compared with the 18G1 needle (3.8 vs 2.5, P < .001) and was not statistically different from the 18G2 needle (3.8 vs 3.5, P = .68). FNB needles (P < .001) and 3 fanning passes (P ≤ .001) were independent predictors of the number of portal tracts. A novel 19G EUS-guided liver biopsy needle provides superior histologic yield compared with 18G percutaneous needles and existing 19G FNA and core needles. Moreover, the 22G FNB needle may be adequate for liver biopsy sampling. Investigations are underway to determine whether these results can be replicated in a clinical setting. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Feasibility of tracked electrodes for use in epilepsy surgery
NASA Astrophysics Data System (ADS)
Holmes, David; Brinkmann, Benjamin; Hanson, Dennis; Worrell, Gregory; Robb, Richard; Holton, Leslie
2016-03-01
Subdural electrode recording is commonly used to evaluate intractable epilepsy. In order to accurately record electrical activity responsible for seizure, electrodes must be positioned precisely near targets of interest, often indicated preoperatively through imaging studies. To achieve accurate placement, a large craniotomy is used to expose the brain surface. With the intent of limiting the size and improving the location of craniotomy for electrode placement, we examined magnetic tracking for localization of electrode strips. Commercially available electrode strips were attached to specialized magnetic tracking sensors developed by Medtronic plc. In a rigid phantom we evaluated the strips to determine the accuracy of electrode placement on targets. We further conducted an animal study to evaluate the impact of magnetic field interference during data collection. The measured distance between the physical fiducial and lead coil of the electrode strip was 1.32 +/- 1.03mm in the phantom experiments. The tracking system induces a very strong signal in the electrodes in the Very Low Frequency, an International Telecommunication Union (ITU) designated frequency band, from 3 kHz to 30 kHz. The results of the animal experiment demonstrated both tracking feasibility and data collection.
Lorias Espinoza, Daniel; Ordorica Flores, Ricardo; Minor Martínez, Arturo; Gutiérrez Gnecchi, José Antonio
2014-06-01
Various methods for evaluating laparoscopic skill have been reported, but without detailed information on the configuration used they are difficult to reproduce. Here we present a method based on the trigonometric relationships between the instruments used in a laparoscopic training platform in order to provide a tool to aid in the reproducible assessment of surgical laparoscopic technique. The positions of the instruments were represented using triangles. Basic trigonometry was used to objectively establish the distances among the working ports RL, the placement of the optical port h', and the placement of the surgical target OT. The optimal configuration of a training platform depends on the selected working angles, the intracorporeal/extracorporeal lengths of the instrument, and the depth of the surgical target. We demonstrate that some distances, angles, and positions of the instruments are inappropriate for satisfactory laparoscopy. By applying basic trigonometric principles we can determine the ideal placement of the working ports and the optics in a simple, precise, and objective way. In addition, because the method is based on parameters known to be important in both the performance and quantitative quality of laparoscopy, the results are generalizable to different training platforms and types of laparoscopic surgery.
WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dadkhah, H; Wu, X; Kim, Y
Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls asmore » well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.« less
Development, diagnostic and applications of radio-frequency plasma reactor
NASA Astrophysics Data System (ADS)
Puac, N.
2008-07-01
In many areas of the industry, plasma processing of materials is a vital technology. Nonequilibrium plasmas proved to be able to produce chemically reactive species at a low gas temperature while maintaining highly uniform reaction rates over relatively large areas (Makabe and Petrovic 2006). At the same time nonequilibrium plasmas provide means for good and precise control of the properties of active particles that determine the surface modification. Plasma needle is one of the atmospheric pressure sources that can be used for treatment of the living matter which is highly sensitive when it comes to low pressure or high temperatures (above 40 C). Dependent on plasma conditions, several refined cell responses are induced in mammalian cells (Sladek et al. 2005). It appears that plasma treatment may find many biomedical applications. However, there are few data in the literature about plasma effects on plant cells and tissues. So far, only the effect of low pressure plasmas on seeds was investigated. It was shown that short duration pretreatments by non equilibrium low temperature air plasma were stimulative in light induced germination of Paulownia tomentosa seeds (Puac et al. 2005). As membranes of plants have different properties to those of animals and as they show a wide range of properties we have tried to survey some of the effects of typical plasma which is envisaged to be used in biotechnological applications on plant cells. In this paper we will make a comparison between two configurations of plasma needle that we have used in treatment of biological samples (Puac et al. 2006). Difference between these two configurations is in the additional copper ring that we have placed around glass tube at the tip of the needle. We will show some of the electrical characteristics of the plasma needle (with and without additional copper ring) and, also, plasma emission intensity obtained by using fast ICCD camera.
Needle tip visibility in 3D ultrasound images
NASA Astrophysics Data System (ADS)
Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo
2017-03-01
Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.
High-precision control of LSRM based X-Y table for industrial applications.
Pan, J F; Cheung, Norbert C; Zou, Yu
2013-01-01
The design of an X-Y table applying direct-drive linear switched reluctance motor (LSRM) principle is proposed in this paper. The proposed X-Y table has the characteristics of low cost, simple and stable mechanical structure. After the design procedure is introduced, an adaptive position control method based on online parameter identification and pole-placement regulation scheme is developed for the X-Y table. Experimental results prove the feasibility and its priority over a traditional PID controller with better dynamic response, static performance and robustness to disturbances. It is expected that the novel two-dimensional direct-drive system find its applications in high-precision manufacture area. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.
Precise computer controlled positioning of robot end effectors using force sensors
NASA Technical Reports Server (NTRS)
Shieh, L. S.; Mcinnis, B. C.; Wang, J. C.
1988-01-01
A thorough study of combined position/force control using sensory feedback for a one-dimensional manipulator model, which may count for the spacecraft docking problem or be extended to the multi-joint robot manipulator problem, was performed. The additional degree of freedom introduced by the compliant force sensor is included in the system dynamics in the design of precise position control. State feedback based on the pole placement method and with integral control is used to design the position controller. A simple constant gain force controller is used as an example to illustrate the dependence of the stability and steady-state accuracy of the overall position/force control upon the design of the inner position controller. Supportive simulation results are also provided.
NASA Technical Reports Server (NTRS)
Carter, Gregory A.; Spiering, Bruce A.
2000-01-01
The present study utilized regression analysis to identify: wavebands and band ratios within the 400-850 nm range that could be used to estimate total chlorophyll concentration with minimal error; and simple regression models that were most effective in estimating chlorophyll concentrations were measured for two broadleaved species, a broadleaved vine, a needle-leaved conifer, and a representative of the grass family.Overall, reflectance, transmittance, and absorptance corresponded most precisely with chlorophyll concentration at wavelengths near 700 nm, although regressions were strong as well in the 550-625 nm range.
Kim, Aram; Kretch, Kari S; Zhou, Zixuan; Finley, James M
2018-05-09
Successful negotiation of obstacles during walking relies on the integration of visual information about the environment with ongoing locomotor commands. When information about the body and environment are removed through occlusion of the lower visual field, individuals increase downward head pitch angle, reduce foot placement precision, and increase safety margins during crossing. However, whether these effects are mediated by loss of visual information about the lower extremities, the obstacle, or both remains to be seen. Here, we used a fully immersive, virtual obstacle negotiation task to investigate how visual information about the lower extremities is integrated with information about the environment to facilitate skillful obstacle negotiation. Participants stepped over virtual obstacles while walking on a treadmill with one of three types of visual feedback about the lower extremities: no feedback, end-point feedback, or a link-segment model. We found that absence of visual information about the lower extremities led to an increase in the variability of leading foot placement after crossing. The presence of a visual representation of the lower extremities promoted greater downward head pitch angle during the approach to and subsequent crossing of an obstacle. In addition, having greater downward head pitch was associated with closer placement of the trailing foot to the obstacle, further placement of the leading foot after the obstacle, and higher trailing foot clearance. These results demonstrate that the fidelity of visual information about the lower extremities influences both feed-forward and feedback aspects of visuomotor coordination during obstacle negotiation.
Neggers, S F W; Langerak, T R; Schutter, D J L G; Mandl, R C W; Ramsey, N F; Lemmens, P J J; Postma, A
2004-04-01
Transcranial Magnetic Stimulation (TMS) delivers short magnetic pulses that penetrate the skull unattenuated, disrupting neural processing in a noninvasive, reversible way. To disrupt specific neural processes, coil placement over the proper site is critical. Therefore, a neural navigator (NeNa) was developed. NeNa is a frameless stereotactic device using structural and functional magnetic resonance imaging (fMRI) data to guide TMS coil placement. To coregister the participant's head to his MRI, 3D cursors are moved to anatomical landmarks on a skin rendering of the participants MRI on a screen, and measured at the head with a position measurement device. A method is proposed to calculate a rigid body transformation that can coregister both sets of coordinates under realistic noise conditions. After coregistration, NeNa visualizes in real time where the device is located with respect to the head, brain structures, and activated areas, enabling precise placement of the TMS coil over a predefined target region. NeNa was validated by stimulating 5 x 5 positions around the 'motor hotspot' (thumb movement area), which was marked on the scalp guided by individual fMRI data, while recording motor-evoked potentials (MEPs) from the abductor pollicis brevis (APB). The distance between the center of gravity (CoG) of MEP responses and the location marked on the scalp overlying maximum fMRI activation was on average less then 5 mm. The present results demonstrate that NeNa is a reliable method for image-guided TMS coil placement.
Muñoz, Juan; Iglesias, Manuel; Chao, Eduardo Lloret; Bussy, Christian
2015-04-01
To assess ultrasound guided transarterial coil placement (UGTACP) for occlusion of the internal carotid artery (ICA) and external carotid artery (ECA) in horses. Cadaveric and in vivo study. Cadaveric horses (n = 10), healthy horses (3), and 1 clinical case. Cadaveric and in vivo (healthy horses): UGTACP was performed in the caudal part of the ICA and ECA. Coil placement in the rostral part of the ICA was performed blindly and controlled by conventional radiography. No coils were placed in the rostral part of the ECA. UGTACP of the ICA was in a horse with guttural pouch mycosis of the left guttural pouch. Accurate ultrasound-guided catheterization of the ICA and ECA was performed in all specimens. Ultrasound-guided coil placement was successfully performed in all cases except 1. No complications occurred in the in vivo study. The clinical case fully recovered and returned to its intended use. Based on our study, UGTACP of the ICA and ECA caudal part is a feasible alternative to fluoroscopy. An advantage of this technique is the accuracy with which you can catheterize both ICA and ECA and the ability to identify unusual branching at the origin of the ICA. Regarding the rostral part of the ICA, angiographic catheter guidance in this region is probably more precise using fluoroscopy as it is performed blindly. In a clinical situation, combination of US and fluoroscopy guidance can result in reduction of radiation exposure time. © Copyright 2014 by The American College of Veterinary Surgeons.
Recovering Infectious HIV from Novel Syringe-Needle Combinations with Low Dead Space Volumes.
Abdala, Nadia; Patel, Amisha; Heimer, Robert
This study determines if detachable syringe-needle combinations redesigned to reduce their dead space volume may substantially reduce the burden of exposure to infectious HIV among people who inject drugs. Two novel, low dead space (LDS) syringe-needle designs-one added a piston to the plunger (LDS syringe) and the other added a filler to the needle (LDS needle) to reduce their dead space-were compared to standard detachable needle-syringe combinations and to syringes with fixed needles. LDS and standard syringes attached to LDS and standard needles of 23-, 25-, and 27-gauge size were contaminated with HIV-infected blood in the laboratory. The proportion of syringe-needle combinations containing infectious HIV was analyzed after syringes were (1) stored up to 7 days at 22°C or (2) rinsed with water. Detachable syringes attached to 25-gauge needles yielded comparable proportions of syringes with infectious HIV, whether the needle was standard or LDS. Among needles of greater diameter (23 gauge), LDS needles tended to reduce recoverable HIV to a greater extent than standard needles. Syringes with fixed needles showed superior results to LDS syringes attached to needles of equivalent diameter and were less likely to get clogged by blood. Detachable LDS syringe-needle designs must be recommended with caution since they still pose potential risk for HIV transmission. Distribution of LDS syringes and needles must be accompanied by recommendations and instructions for their proper rinsing and disinfection in order to reduce viral burden and chances of needle clogging.
Wolf, Bruce L; Marks, Albert; Fahrenholz, John M
2006-07-01
Current Occupational Safety and Health Administration (OSHA) guidelines mandate the use of safety needles when allergy injections are given. Safety needles for intradermal testing remain optional. Whether safety needles reduce the number of accidental needle sticks (ANSs) in the outpatient setting has yet to be proven. To determine the rate of ANSs with new (safety) needles vs old needles used in allergy immunotherapy and intradermal testing. Allergy practices from 22 states were surveyed by e-mail. Seventy practices (28%) responded to the survey. Twice as many ANSs occurred in practices giving immunotherapy when using new needles vs old needles (P < .01). The rate of ANSs was roughly the same for intradermal testing with new needles vs old needles. These findings further question whether OSHA's guidelines for safety needle use in outpatient practice need revision and if allergy practices might be excluded from the requirement to use safety needles.
Accurate guide wire of lag screw placement in the intertrochanteric fractures: a technical note.
Li, Jiang; Wang, Liao; Li, Xiaodong; Feng, Kai; Tang, Jian; Wang, Xiaoqing
2017-09-01
Cephalomedullary fixations are commonly used in the treatment of intertrochanteric fractures. In clinical practice, one of the difficulties is when we exit the guide wire in a wrong position of femoral neck and insert near the hole again, the guide wire often flow into the previous track. This study develops a surgical technique to direct the guide wire to slip away the previous track and slip into a right position. When guide wire is exited to the cortex of femoral, we let the wire in and out at the cortical layer for several times to enlarge the entry hole. After that, electric drill is inverted, rubbed and entered slowly at a right angle. When guide wire encountered new resistance, the electric drill is turned back instantly. This technique can help trauma and orthopedic surgeons to obtain precision placement of the lag screw after the first try is failed.
Class II composite resin restorations: faster, easier, predictable.
Jackson, R D
2016-11-18
Composite resin continues to displace amalgam as the preferred direct restorative material in developed countries. Even though composite materials have evolved to include nanoparticles with high physical properties and low shrinkage stress, dentists have been challenged to efficiently create quality, long lasting, predictable restorations. Unlike amalgam, composite resin cannot be condensed making the establishment of a predictable, proper contact more difficult. In addition, composite requires an understanding of adhesives and an appreciation for their exacting application. These facts combined with the precise adaptation and light-curing of multiple layers makes placement of quality Class II composite restorations tedious and time-consuming. For private practicing dentists, it can also have an effect on economic productivity. Clinicians have always wanted an easier, efficient placement technique for posterior composite restorations that rivals that for amalgam. It appears that advances in instrumentation, materials and technology have finally delivered it.
Updates of operative techniques for upper airway stimulation.
Heiser, Clemens; Thaler, Erica; Boon, Maurits; Soose, Ryan J; Woodson, B Tucker
2016-09-01
Selective upper airway stimulation has been established as an additional treatment for obstructive sleep apnea (OSA). Essential for the treatment is the precise placement of the cuff electrode for select branches of the hypoglossal nerve, which innervate the protrusors and stiffeners of the tongue. A direct approach to the distal hypoglossal nerve has been established to achieve this goal. For surgeons, detailed knowledge of this anatomy is vital. Another decisive step is the placement of the sensing lead between the intercostal muscles. Also, the complexity of follow-up care postoperatively should be kept in mind. The aim of this article is to provide the latest knowledge on the neuroanatomy of the hypoglossal nerve and to give surgeons a step-by-step guide on the current operative technique. Laryngoscope, 126:S12-S16, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana
2015-01-01
The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469
New transurethral system for interstitial radiation of prostate cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumgartner, G.; Callahan, D.; McKiel, C.F. Jr.
Direct endoscopic implantation of radioactive materials for carcinoma of the prostate without an open operation was accomplished by the use of modified existing transurethral instrumentation and techniques. The closed approach seems applicable particularly to the geriatric population, which is afflicted more commonly but is frequently not treated because of concurrent diseases or because the patient had transurethral resection of the prostate as a diagnostic procedure. Eleven patients were implanted using the transurethral route. Implantations were accomplished successfully with extremely low morbidity. Along with more conventional dosimetry studies, computer tomography was used to assess the placement of seeds. The direct visualizationmore » of the method suggests a potential for greater precision of seed placement as illustrated by computer tomography. In addition, this new instrumentation and method offers a low-risk procedure for carcinoma of the prostate that can be performed on an outpatient basis for selected patients.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siauw, Timmy; Cunha, Adam; Berenson, Dmitry
Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the finalmore » needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, {delta}. The candidate needle set consisted of 5000 needles, and a range of {delta} values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of {delta} values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer needles than the current HDR brachytherapy workflow. Combined with robot assisted brachytherapy, this system has the potential to reduce side effects associated with treatment. A physical trial should be done to test the implant feasibility of NPIP needle configurations.« less
Geographical and climatic limits of needle types of one- and two-needled pinyon pines
Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.
2008-01-01
Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes. Pinus monophylla and californiarum-type needles occur in regions with high winter precipitation. Pinus edulis and fallax-type needles are found in regions with high monsoon precipitation. Areas supporting californiarum-type and fallax-type needle distributions are additionally characterized by a more extreme May-June drought. Main conclusions: These pinyon needle types seem to reflect the amount and seasonality of precipitation. The single needle fascicle characterizing the fallax type may be an adaptation to early summer or periodic drought, while the single needle of Pinus monophylla may be an adaptation to summer-autumn drought. Although the needles fit into four distinct categories, the parent trees are sometimes less easily classified, especially near their ancestral Pleistocene ranges in the Mojave and northern Sonoran deserts. The abundance of trees with both one- and two-needled fascicles in the zones between P. monophylla, P. edulis and fallax-type populations suggest that needle fascicle number is an unreliable characteristic for species classification. Disregarding needle fascicle number, the fallax-type needles are nearly identical to P. edulis, supporting Little's (1968) initial classification of these trees as P. edulis var. fallax, while the californiarum-type needles have a distinctive morphology supporting Bailey's (1987) classification of this tree as Pinus californiarum.
Zhu, Zhaojun; Hofauer, Benedikt; Heiser, Clemens
2018-06-01
The following report presents a case of two late embedded hypoglossus branches during implantation of an upper airway stimulation device that caused a mixed activation of the tongue when included in the stimulation cuff. In the end, correct cuff placement could be achieved by careful examination of the hypoglossal nerve anatomy, precise nerve dissection, tongue motion analysis and intraoperative nerve monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.
Stainless hooks to bond lower lingual retainer.
Durgekar, Sujala G; Nagaraj, K
2011-01-01
We introduced a simple and economical technique for precise placement of lower lingual retainers. Two stainless steel hooks made of 0.6mm wire are placed interdentally in the embrasure area between canine and lateral incisor bilaterally to lock the retainer wire in the correct position. Etch, rinse and dry the enamel surfaces with the retainer passively in place, then bond the retainer with light-cured adhesive. Hooks are simple to fabricate and eliminate the need for a transfer tray.
NASA Astrophysics Data System (ADS)
Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.
2017-05-01
MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The proposed needle insertion sequencing can therefore assist in delivering an optimal dose in HDR prostate brachytherapy.
Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z
2016-07-01
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Real-time self-calibration of a tracked augmented reality display
NASA Astrophysics Data System (ADS)
Baum, Zachary; Lasso, Andras; Ungi, Tamas; Fichtinger, Gabor
2016-03-01
PURPOSE: Augmented reality systems have been proposed for image-guided needle interventions but they have not become widely used in clinical practice due to restrictions such as limited portability, low display refresh rates, and tedious calibration procedures. We propose a handheld tablet-based self-calibrating image overlay system. METHODS: A modular handheld augmented reality viewbox was constructed from a tablet computer and a semi-transparent mirror. A consistent and precise self-calibration method, without the use of any temporary markers, was designed to achieve an accurate calibration of the system. Markers attached to the viewbox and patient are simultaneously tracked using an optical pose tracker to report the position of the patient with respect to a displayed image plane that is visualized in real-time. The software was built using the open-source 3D Slicer application platform's SlicerIGT extension and the PLUS toolkit. RESULTS: The accuracy of the image overlay with image-guided needle interventions yielded a mean absolute position error of 0.99 mm (95th percentile 1.93 mm) in-plane of the overlay and a mean absolute position error of 0.61 mm (95th percentile 1.19 mm) out-of-plane. This accuracy is clinically acceptable for tool guidance during various procedures, such as musculoskeletal injections. CONCLUSION: A self-calibration method was developed and evaluated for a tracked augmented reality display. The results show potential for the use of handheld image overlays in clinical studies with image-guided needle interventions.
Siegenthaler, Andreas; Haug, Matthias; Eichenberger, Urs; Suter, Marc Rene; Moriggl, Bernhard
2013-05-01
Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks. Wiley Periodicals, Inc.
NASA Robotic Neurosurgery Testbed
NASA Technical Reports Server (NTRS)
Mah, Robert
1997-01-01
The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.
NASA Robotic Neurosurgery Testbed
NASA Technical Reports Server (NTRS)
Mah, Robert
1997-01-01
The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations. In neurosurgery, the needle used in the standard stereotactic CT (Computational Tomography) or MRI (Magnetic Resonance Imaging) guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled 'Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification' is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borot de Battisti, M; Maenhout, M; Lagendijk, J J W
Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. Themore » dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.« less
Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian
2016-01-01
To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P < 0.05). Thirty min after needle withdrawal, the differences of the indices of cardiovascular function between the two groups were not significant (all P > 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.
[Needle breakage during mandibular block anaesthesia: prevention and retrieval].
Baart, J A; van Amerongen, W E; de Jong, K J M; Allard, R H B
2006-12-01
Disposable needles for dental local anaesthesia do not break easily. Still, needle breakage does occur, and is mainly caused by unexpected movements of the patient or pre-use bending of the needle by the dentist. If a dental needle breaks while administering local anaesthesia, the dentist should prevent panic. If the patient opens his mouth wide the needle might still be visible. If so, the needle is removed. If the needle is no longer visible, the site where the needle has penetrated the mucosa should be marked with a permanent marker. The dentist will contact a maxillofacial surgeon for immediate consultation. The maxillofacial surgeon will try to retrieve the broken dental needle under general anaesthesia.
Treatment of Skin Depression with Combined Upward Suture Traction and Percutaneous Subcision
Bins-Ely, Jorge; Paulo, Elizabeth Machado; Lee, Kuang Hee
2015-01-01
Background: Scar retraction and soft-tissue depression may compromise aesthetics and cause social embarrassment. The purpose of this study was to evaluate the results of treating soft-tissue depressions or retractions at varied anatomy regions with combined upward suture traction and percutaneous subcision. Methods: There were 40 patients (age: mean, 39 years; range, 22–55 years; 39 women and 1 man) (total, 77 soft-tissue lesions) who had treatment with the present technique from 1996 to 2013. Postoperative follow-up was from 6 months to 2 years. The treated anatomic areas were evaluated in 5 groups: (1) face (8 patients; 8 lesions); (2) gluteal (16 patients; 46 lesions); (3) breast (7 patients; 10 lesions); (4) abdomen (7 patients; 7 lesions); and (5) lower limb (2 patients; 6 lesions). The technique included placing a 2-0 nylon monofilament suture deep at the core of the depression, pulling vertically up with the suture, and using a needle or miniblade (placed percutaneously or through a small incision) to release the adhesions. Results: The depressions were released successfully in all patients. Bruises around treated areas persisted for 2–3 weeks. Moderate induration persisted until 3 months. In the gluteal region, 6 patients who had retracted areas with diameter >5 cm developed seroma after treatment; the seromas resolved after needle aspiration or placement of a Penrose drain for 2 weeks (2 patients). Conclusion: The present results confirmed the efficacy of the combined subcision method with upward traction at diverse body sites as previously reported for inverted nipple in the breast. PMID:26579340
Lim, Kai-Zheong; Goldschlager, Tony; Chandra, Ronil V
2017-10-01
Intra-operative blood loss remains a major cause of perioperative morbidity for patients with hypervascular spinal metastasis undergoing surgery. Pre-operative embolization is used to reduce intraoperative blood loss and operative time. This is commonly performed under general anesthesia via a trans-arterial approach, which carries a risk of spinal stroke. We propose an alternative technique for embolization of hypervascular metastases using the Onyx embolic agent via a percutaneous direct intra-tumoural injection under local anesthesia and sedation to reduce embolization risks and procedure time, as well as operative blood loss and operative time. A 74-year-old man presented with thoracic myelopathy with back and radicular pain on background of metastatic renal cell carcinoma. Magnetic resonance imaging (MRI) revealed a 3cm mass centered on the right lamina of T10 with extension into the spinal canal. The patient underwent a percutaneous imaging-guided direct intra-tumoural contrast parenchymogram, and Onyx embolization via a single needle. Initial needle placement and tumour assessment was completed in 30min; embolization time was 15min. Complete devascularization was achieved with no complications. Surgical resection was performed with lower than expected operative blood loss (150ml) and operative time (90min). His pre-operative symptoms improved, and he was discharged home the following day. At 6-month follow-up there was no recurrence of his symptoms. Further evaluation of direct percutaneous intra-tumoural Onyx embolization for hypervascular spinal tumours is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effects of repeated transvaginal aspiration of immature follicles on mare health and ovarian status.
Velez, I C; Arnold, C; Jacobson, C C; Norris, J D; Choi, Y H; Edwards, J F; Hayden, S S; Hinrichs, K
2012-12-01
Transvaginal ultrasound-guided follicle aspiration (TVA) is performed clinically but there is little information available on complications associated with this procedure. It is possible that TVA is associated with damage to the ovary and may induce peritonitis or peritoneal adhesions. This study was conducted to determine the effect of repeated TVA on mare health and ovarian status. Thirty-two mares were used for oocyte recovery via repeated TVA over a 3 year period; different mares were used each year. In Year 1, ovarian status was monitored in 11 mares by transrectal palpation and ultrasonography. In Year 2, 6 of 11 mares underwent abdominocentesis and were examined by laparoscopy after one TVA and again after multiple TVAs. In Year 3, 10 mares underwent multiple TVAs with either a 15 or a 12 gauge needle and the ovaries were removed for examination. Four hundred and twenty-seven aspiration sessions (390 via TVA and 37 via needle placement through the flank) and 3202 follicle punctures (3161 TVA and 41 flank) were performed. One mare developed an ovarian abscess. Transient rectal bleeding was evident after 16% of TVA sessions. No adhesions were found on laparoscopic or gross examination of ovaries and there were minimal changes on histological evaluation. Follicle aspiration carries a small possibility (< 0.5%) of ovarian abscess formation. There is a possibility of rectal abrasion or puncture but little gross or histological damage to the ovary. These results provide a basis for using prophylactic administration of antibiotics after TVA and for advising mare owners of the rare but potential complications associated with the procedure.
Behavior of Tip-Steerable Needles in ex vivo and in vivo Tissue
Majewicz, Ann; Marra, Steven P.; van Vledder, Mark G.; Lin, MingDe; Choti, Michael A.; Song, Danny Y.; Okamura, Allison M.
2012-01-01
Robotic needle steering is a promising technique to improve the effectiveness of needle-based clinical procedures, such as biopsies and ablation, by computer-controlled, curved insertions of needles within solid organs. In this paper, we explore the capabilities, challenges, and clinical relevance of asymmetric-tip needle steering though experiments in ex vivo and in vivo tissue. We evaluate the repeatability of needle insertion in inhomogeneous biological tissue and compare ex vivo and in vivo needle curvature and insertion forces. Steerable needles curved more in kidney than in liver and prostate, likely due to differences in tissue properties. Pre-bent needles produced higher insertion forces in liver and more curvature in vivo than ex vivo. When compared to straight stainless steel needles, steerable needles did not cause a measurable increase in tissue damage and did not exert more force during insertion. The minimum radius of curvature achieved by pre-bent needles was 5.23 cm in ex vivo tissue, and 10.4 cm in in vivo tissue. The curvatures achieved by bevel tip needles were negligible for in vivo tissue. The minimum radius of curvature for bevel tip needles in ex vivo tissue was 16.4 cm; however, about half of the bevel tip needles had negligible curvatures. We also demonstrate a potential clinical application of needle steering by targeting and ablating overlapping regions of cadaveric canine liver. PMID:22711767
Axe, Jeremie M; Axe, Michael J
2013-10-01
Unguided approaches have not demonstrated evidence of highly accurate intra-articular glenohumeral injections. The purpose of this study was to assess the accuracy of a posterior approach bone touch technique in conscious subjects without shoulder pathology as a first step in developing an accurate, reliable technique for use in patients. Twenty-six young subjects (age 22-26) without shoulder pathology (BMI 24 +/- 3), had bilateral shoulders injected while awake and seated. A 20 gauge 3.5-inch needle was introduced 1.5 cm below the scapular spine mid-way between the posterior lateral acromial corner and the posterior axillary crease. In Trial I, 20 shoulders were injected. After touching the humerus, the arm was oscillated. The needle advanced to 4-5 cm and 10 mL of dye injected. Pop and ease of flow were recorded. Immediate room change, spot fluoroscopy, and independent experienced radiology reading followed. In Trial II, 32 shoulders were injected. The technique was modified to touching the humerus, externally rotating the arm 25 degrees, and while remaining in bone contact, delivering 10 mL of dye. The same data as Trial I was recorded. In Trial I, 14/20 (70 percent) had dye within the glenohumeral joint. Five of seven failures were too anterior showing dye around the subscapularis muscle and all were associated with a pop. In Trial II, 31/32 (97 percent) had dye within glenohumeral joint. Twenty-three of 32 (72 percent) had a "pop," including the failure. Overall, 45/52 (87 percent) had dye within glenohumeral joint. Thirty-one of 52 (71 percent) of all shoulders had a "pop." Twenty-three of 52 (44 percent) shoulders had pain, resolving within 24 hours. A modified (Delaware) posterior bone touch technique for glenohumeral joint injection is 97 percent accurate in conscious healthy young subjects. Pop and ease of flow are not always indicative of correct needle placement. This study serves as an important first step in determining an optimum approach for injecting pathologic glenohumeral joints with corticosteroids or hyaluronic acid. IV Case Series.
Leatherman, Matthew L; Held, Jenny M; Fluke, Laura M; McEvoy, Christian S; Inaba, Kenji; Grabo, Daniel; Martin, Matthew J; Earley, Angela S; Ricca, Robert L; Polk, Travis M
2017-07-01
Tension pneumothorax (tPTX) remains a significant cause of potentially preventable death in military and civilian settings. The current prehospital standard of care for tPTX is immediate decompression with a 14-gauge 8-cm angiocatheter; however, failure rates may be as high as 17% to 60%. Alternative devices, such as 10-gauge angiocatheter, modified Veress needle, and laparoscopic trocar, have shown to be potentially more effective in animal models; however, little is known about the relative insertional safety or mechanical stability during casualty movement. Seven soft-embalmed cadavers were intubated and mechanically ventilated. Chest wall thickness was measured at the second intercostal space at the midclavicular line (2MCL) and the fifth intercostal space along the anterior axillary line (5AAL). CO2 insufflation created a PTX, and needle decompression was then performed with a randomized device. Insertional depth was measured between hub and skin before and after simulated casualty transport. Thoracoscopy was used to evaluate for intrapleural placement and/or injury during insertion and after movement. Cadaver demographics, device displacement, device dislodgment, and injuries were recorded. Three decompressions were performed at each site (2MCL/5AAL), totaling 12 events per cadaver. Eighty-four decompressions were performed. Average cadaver age was 59 years, and body mass index was 24 kg/m. The CWT varied between cadavers because of subcutaneous emphysema, but the average was 39 mm at the 2MCL and 31 mm at the 5AAL. Following movement, the 2MCL site was more likely to become dislodged than the 5AAL (67% vs. 17%, p = 0.001). Median displacement also differed between 2MCL and 5AAL (23 vs. 2 mm, p = 0.001). No significant differences were noted in dislodgement or displacement between devices. Five minor lung injuries were noted at the 5AAL position. Preliminary results from this human cadaver study suggest the 5AAL position is a more stable and reliable location for thoracic decompression of tPTX during combat casualty transport. Therapeutic study, level III.
Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.
Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor
2013-10-01
We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.
Does Needle Rotation Improve Lesion Targeting?
Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan
2011-01-01
Background Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. Methods We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. Results These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. Conclusion The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. PMID:21360796
Ahn, H J; Choi, D H; Kim, C S
2006-07-01
Paraesthesia during regional anaesthesia is an unpleasant sensation for patients and, more importantly, in some cases it is related to neurological injury. Relatively few studies have been conducted on the frequency of paraesthesia during combined spinal epidural anaesthesia. We compared two combined spinal epidural anaesthesia techniques: the needle-through-needle technique and the double segment technique in this respect. We randomly allocated 116 parturients undergoing elective Caesarean section to receive anaesthesia using one of these techniques. Both techniques were performed using a 27G pencil point needle, an 18G Tuohy needle, and a 20G multiport epidural catheter from the same manufacturer. The overall frequency of paraesthesia was higher in the needle-through-needle technique group (56.9% vs. 31.6%, p = 0.011). The frequency of paraesthesia at spinal needle insertion was 20.7% in the needle-through-needle technique group and 8.8% in the double segment technique group; whereas the frequency of paraesthesia at epidural catheter insertion was 46.6% in the needle-through-needle technique group and 24.6% in the double segment technique group.
Adams, Stephen B; Moore, George E; Elrashidy, Mohammed; Mohamed, Ahmed; Snyder, Paul W
2010-08-01
To assess joint contamination with tissue and hair after arthrocentesis of equine fetlock joints. Experimental. Limb specimens from 8 equine cadavers. Soft tissues including the joint capsule were harvested from the dorsal aspect of the fetlock joints and mounted on a wooden frame. Needles inserted through the joint tissue preparation were flushed into tissue culture plates that were examined for tissue and hair debris. Variables evaluated were gauge and type of needle (16, 18, 20, and 22 G sharp disposable needles and 20 G disposable spinal needles with stylet), number of times each needle was used (1, 2, 3, 4), length of hair (unclipped, clipped, shaved with razor), and needle insertion speed (fast, slow). Descriptive and statistical evaluations were performed. Tissue contamination was identified in 1145 of 1260 wells and hair contamination was identified in 384 of 1260 wells. Twenty gauge needles inserted through unclipped hair resulted in the least amount of hair contamination. Compared with 20 G needles with fast insertion 1 time through unclipped hair the odds ratios for contamination with hair were significantly greater for 16 G sharp disposable needles, 20 G spinal needles, clipped hair, shaved hair, and reuse of the needles. Spinal needles inserted through unclipped hair transferred many long hairs into the joint space. Reuse of needles for arthrocentesis should be avoided. Removal of hair is not indicated for arthrocentesis with sharp injection needles but is recommended when using spinal needles with stylets. Joint contamination with hair and tissue debris will be decreased by specific needle insertion techniques. Decreased contamination of joints may reduce the frequency of joint infections after arthrocentesis.
EUS Needle Identification Comparison and Evaluation study (with videos).
Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin Teodor; Fink, Peter P; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T; van der Heijden, Erik H F M; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R; Lee, Linda S; Aslanian, Harry R; Wang, Andrew Y; Shami, Vanessa M; Markowitz, Arnold; Siddiqui, Ali A; Mishra, Girish; Scheiman, James M; Isenberg, Gerard; Siddiqui, Uzma D; Shah, Raj J; Buxbaum, James; Watson, Rabindra R; Willingham, Field F; Bhutani, Manoop S; Levy, Michael J; Harris, Cynthia; Wallace, Michael B; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D'Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S; Freeman, Simon; McCowan, Timothy C; de Araujo, Cyrillo Rodrigues; Patel, Akash; Ali, Mohammad Adel; Campbell, Garth; Chen, Edward; Vilmann, Peter
2016-09-01
EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. Copyright © 2016 American Society for Gastrointestinal Endoscopy. All rights reserved.