Precise Truss Assembly using Commodity Parts and Low Precision Welding
NASA Technical Reports Server (NTRS)
Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, William R.; Correll, Nikolaus
2013-01-01
We describe an Intelligent Precision Jigging Robot (IPJR), which allows high precision assembly of commodity parts with low-precision bonding. We present preliminary experiments in 2D that are motivated by the problem of assembling a space telescope optical bench on orbit using inexpensive, stock hardware and low-precision welding. An IPJR is a robot that acts as the precise "jigging", holding parts of a local assembly site in place while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (in this case, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. We report the challenges of designing the IPJR hardware and software, analyze the error in assembly, document the test results over several experiments including a large-scale ring structure, and describe future work to implement the IPJR in 3D and with micron precision.
Precision Medicine In Action | NIH MedlinePlus the Magazine
... please turn JavaScript on. Feature: NIH Precision Medicine Initiative Precision Medicine In Action Past Issues / Fall 2015 ... To me, precision medicine and the Precision Medicine Initiative means a shift in the way we're ...
Precise Truss Assembly Using Commodity Parts and Low Precision Welding
NASA Technical Reports Server (NTRS)
Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, W. R.; Correll, Nikolaus
2014-01-01
Hardware and software design and system integration for an intelligent precision jigging robot (IPJR), which allows high precision assembly using commodity parts and low-precision bonding, is described. Preliminary 2D experiments that are motivated by the problem of assembling space telescope optical benches and very large manipulators on orbit using inexpensive, stock hardware and low-precision welding are also described. An IPJR is a robot that acts as the precise "jigging", holding parts of a local structure assembly site in place, while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (for this prototype, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. The analysis of the assembly error and the results of building a square structure and a ring structure are discussed. Options for future work, to extend the IPJR paradigm to building in 3D structures at micron precision are also summarized.
[Precision nutrition in the era of precision medicine].
Chen, P Z; Wang, H
2016-12-06
Precision medicine has been increasingly incorporated into clinical practice and is enabling a new era for disease prevention and treatment. As an important constituent of precision medicine, precision nutrition has also been drawing more attention during physical examinations. The main aim of precision nutrition is to provide safe and efficient intervention methods for disease treatment and management, through fully considering the genetics, lifestyle (dietary, exercise and lifestyle choices), metabolic status, gut microbiota and physiological status (nutrient level and disease status) of individuals. Three major components should be considered in precision nutrition, including individual criteria for sufficient nutritional status, biomarker monitoring or techniques for nutrient detection and the applicable therapeutic or intervention methods. It was suggested that, in clinical practice, many inherited and chronic metabolic diseases might be prevented or managed through precision nutritional intervention. For generally healthy populations, because lifestyles, dietary factors, genetic factors and environmental exposures vary among individuals, precision nutrition is warranted to improve their physical activity and reduce disease risks. In summary, research and practice is leading toward precision nutrition becoming an integral constituent of clinical nutrition and disease prevention in the era of precision medicine.
NASA Astrophysics Data System (ADS)
Fagan, Mike; Dueben, Peter; Palem, Krishna; Carver, Glenn; Chantry, Matthew; Palmer, Tim; Schlacter, Jeremy
2017-04-01
It has been shown that a mixed precision approach that judiciously replaces double precision with single precision calculations can speed-up global simulations. In particular, a mixed precision variation of the Integrated Forecast System (IFS) of the European Centre for Medium-Range Weather Forecasts (ECMWF) showed virtually the same quality model results as the standard double precision version (Vana et al., Single precision in weather forecasting models: An evaluation with the IFS, Monthly Weather Review, in print). In this study, we perform detailed measurements of savings in computing time and energy using a mixed precision variation of the -OpenIFS- model. The mixed precision variation of OpenIFS is analogous to the IFS variation used in Vana et al. We (1) present results for energy measurements for simulations in single and double precision using Intel's RAPL technology, (2) conduct a -scaling- study to quantify the effects that increasing model resolution has on both energy dissipation and computing cycles, (3) analyze the differences between single core and multicore processing, and (4) compare the effects of different compiler technologies on the mixed precision OpenIFS code. In particular, we compare intel icc/ifort with gnu gcc/gfortran.
Opto-mechanical system design of test system for near-infrared and visible target
NASA Astrophysics Data System (ADS)
Wang, Chunyan; Zhu, Guodong; Wang, Yuchao
2014-12-01
Guidance precision is the key indexes of the guided weapon shooting. The factors of guidance precision including: information processing precision, control system accuracy, laser irradiation accuracy and so on. The laser irradiation precision is an important factor. This paper aimed at the demand of the precision test of laser irradiator,and developed the laser precision test system. The system consists of modified cassegrain system, the wide range CCD camera, tracking turntable and industrial PC, and makes visible light and near infrared target imaging at the same time with a Near IR camera. Through the analysis of the design results, when it exposures the target of 1000 meters that the system measurement precision is43mm, fully meet the needs of the laser precision test.
Reduction to Outside the Atmosphere and Statistical Tests Used in Geneva Photometry
NASA Technical Reports Server (NTRS)
Rufener, F.
1984-01-01
Conditions for creating a precise photometric system are investigated. The analytical and discriminatory potentials of a photometry obviously result from the localization of the passbands in the spectrum; they do, however, also depend critically on the precision attained. This precision is the result of two different types of precautions. Two procedures which contribute in an efficient manner to achieving greater precision are examined. These two methods are known as hardware related precision and software related precision.
Chen, Yixi; Guzauskas, Gregory F; Gu, Chengming; Wang, Bruce C M; Furnback, Wesley E; Xie, Guotong; Dong, Peng; Garrison, Louis P
2016-11-02
The "big data" era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient-level HEOR analyses. We propose the concept of "precision HEOR", which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient.
Reliable low precision simulations in land surface models
NASA Astrophysics Data System (ADS)
Dawson, Andrew; Düben, Peter D.; MacLeod, David A.; Palmer, Tim N.
2017-12-01
Weather and climate models must continue to increase in both resolution and complexity in order that forecasts become more accurate and reliable. Moving to lower numerical precision may be an essential tool for coping with the demand for ever increasing model complexity in addition to increasing computing resources. However, there have been some concerns in the weather and climate modelling community over the suitability of lower precision for climate models, particularly for representing processes that change very slowly over long time-scales. These processes are difficult to represent using low precision due to time increments being systematically rounded to zero. Idealised simulations are used to demonstrate that a model of deep soil heat diffusion that fails when run in single precision can be modified to work correctly using low precision, by splitting up the model into a small higher precision part and a low precision part. This strategy retains the computational benefits of reduced precision whilst preserving accuracy. This same technique is also applied to a full complexity land surface model, resulting in rounding errors that are significantly smaller than initial condition and parameter uncertainties. Although lower precision will present some problems for the weather and climate modelling community, many of the problems can likely be overcome using a straightforward and physically motivated application of reduced precision.
Chen, Yixi; Guzauskas, Gregory F.; Gu, Chengming; Wang, Bruce C. M.; Furnback, Wesley E.; Xie, Guotong; Dong, Peng; Garrison, Louis P.
2016-01-01
The “big data” era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient–level HEOR analyses. We propose the concept of “precision HEOR”, which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient. PMID:27827859
McNamara, Elizabeth A; Kilim, Holly P; Malabanan, Alan O; Whittaker, LaTarsha G; Rosen, Harold N
The International Society for Clinical Densitometry guidelines recommend using locally derived precision data for spine bone mineral densities (BMDs), but do not specify whether data derived from L1-L4 spines correctly reflect the precision for spines reporting fewer than 4 vertebrae. Our experience suggested that the decrease in precision with successively fewer vertebrae is progressive as more vertebrae are excluded and that the precision for the newer Horizon Hologic model might be better than that for the previous model, and we sought to quantify. Precision studies were performed on Hologic densitometers by acquiring spine BMD in fast array mode twice on 30 patients, according to International Society for Clinical Densitometry guidelines. This was done 10 different times on various Discovery densitometers, and once on a Horizon densitometer. When 1 vertebral body was excluded from analysis, there was no significant deterioration in precision. When 2 vertebrae were excluded, there was a nonsignificant trend to poorer precision, and when 3 vertebrae were excluded, there was significantly worse precision. When 3 or 4 vertebrae were reported, the precision of the spine BMD measurement was significantly better on the Hologic Horizon than on the Discovery, but the difference in precision between densitometers narrowed and was no longer significant when 1 or 2 vertebrae were reported. The results suggest that (1) the measurement of in vivo spine BMD on the new Hologic Horizon densitometer is significantly more precise than on the older Discovery model; (2) the difference in precision between the Horizon and Discovery models decreases as fewer vertebrae are included; (3) the measurement of spine BMD is less precise as more vertebrae are excluded, but still quite reasonable even when only 1 vertebral body is included; and (4) when 3 vertebrae are reported, L1-L4 precision data can reasonably be used to report significance of changes in BMD. When 1 or 2 vertebrae are reported, precision data for 1 or 2 vertebrae, respectively, should be used, because the exclusion of 2-3 vertebrae significantly worsens precision. Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
NCI and the Precision Medicine Initiative®
NCI's activities related to precision medicine focuses on new and expanded precision medicine clinical trials; mechanisms to overcome drug resistance to cancer treatments; and developing a shared digital repository of precision medicine trials data.
Schlienger, M. Eric; Schmale, David T.; Oliver, Michael S.
2001-07-10
A new class of precision powder feeders is disclosed. These feeders provide a precision flow of a wide range of powdered materials, while remaining robust against jamming or damage. These feeders can be precisely controlled by feedback mechanisms.
Precision mechatronics based on high-precision measuring and positioning systems and machines
NASA Astrophysics Data System (ADS)
Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert
2007-06-01
Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.
[Progress in precision medicine: a scientific perspective].
Wang, B; Li, L M
2017-01-10
Precision medicine is a new strategy for disease prevention and treatment by taking into account differences in genetics, environment and lifestyles among individuals and making precise diseases classification and diagnosis, which can provide patients with personalized, targeted prevention and treatment. Large-scale population cohort studies are fundamental for precision medicine research, and could produce best evidence for precision medicine practices. Current criticisms on precision medicine mainly focus on the very small proportion of benefited patients, the neglect of social determinants for health, and the possible waste of limited medical resources. In spite of this, precision medicine is still a most hopeful research area, and would become a health care practice model in the future.
Precision Medicine: Functional Advancements.
Caskey, Thomas
2018-01-29
Precision medicine was conceptualized on the strength of genomic sequence analysis. High-throughput functional metrics have enhanced sequence interpretation and clinical precision. These technologies include metabolomics, magnetic resonance imaging, and I rhythm (cardiac monitoring), among others. These technologies are discussed and placed in clinical context for the medical specialties of internal medicine, pediatrics, obstetrics, and gynecology. Publications in these fields support the concept of a higher level of precision in identifying disease risk. Precise disease risk identification has the potential to enable intervention with greater specificity, resulting in disease prevention-an important goal of precision medicine.
[Calm thinking for precision medicine of breast cancer in the boom].
Jiang, Z F; Xu, F R
2017-02-01
In the past two years, researchers have been exploring the precision medicine. Thanks to the development of sequence industry and clinical study, the big data about the precision medicine have been more and more sufficient. However, how to deal with the precision data is still a question for clinicians. We focus on the hot issues that disturb clinicians most, wanting to help them to make suitable decisions between the traditional and precision medicine of breast cancer. We believe the precision medicine is on the way.
Improving Weather Forecasts Through Reduced Precision Data Assimilation
NASA Astrophysics Data System (ADS)
Hatfield, Samuel; Düben, Peter; Palmer, Tim
2017-04-01
We present a new approach for improving the efficiency of data assimilation, by trading numerical precision for computational speed. Future supercomputers will allow a greater choice of precision, so that models can use a level of precision that is commensurate with the model uncertainty. Previous studies have already indicated that the quality of climate and weather forecasts is not significantly degraded when using a precision less than double precision [1,2], but so far these studies have not considered data assimilation. Data assimilation is inherently uncertain due to the use of relatively long assimilation windows, noisy observations and imperfect models. Thus, the larger rounding errors incurred from reducing precision may be within the tolerance of the system. Lower precision arithmetic is cheaper, and so by reducing precision in ensemble data assimilation, we can redistribute computational resources towards, for example, a larger ensemble size. Because larger ensembles provide a better estimate of the underlying distribution and are less reliant on covariance inflation and localisation, lowering precision could actually allow us to improve the accuracy of weather forecasts. We will present results on how lowering numerical precision affects the performance of an ensemble data assimilation system, consisting of the Lorenz '96 toy atmospheric model and the ensemble square root filter. We run the system at half precision (using an emulation tool), and compare the results with simulations at single and double precision. We estimate that half precision assimilation with a larger ensemble can reduce assimilation error by 30%, with respect to double precision assimilation with a smaller ensemble, for no extra computational cost. This results in around half a day extra of skillful weather forecasts, if the error-doubling characteristics of the Lorenz '96 model are mapped to those of the real atmosphere. Additionally, we investigate the sensitivity of these results to observational error and assimilation window length. Half precision hardware will become available very shortly, with the introduction of Nvidia's Pascal GPU architecture and the Intel Knights Mill coprocessor. We hope that the results presented here will encourage the uptake of this hardware. References [1] Peter D. Düben and T. N. Palmer, 2014: Benchmark Tests for Numerical Weather Forecasts on Inexact Hardware, Mon. Weather Rev., 142, 3809-3829 [2] Peter D. Düben, Hugh McNamara and T. N. Palmer, 2014: The use of imprecise processing to improve accuracy in weather & climate prediction, J. Comput. Phys., 271, 2-18
NASA Astrophysics Data System (ADS)
Chen, Ming; Guo, Jiming; Li, Zhicai; Zhang, Peng; Wu, Junli; Song, Weiwei
2017-04-01
BDS precision orbit determination is a key content of the BDS application, but the inadequate ground stations and the poor distribution of the network are the main reasons for the low accuracy of BDS precise orbit determination. In this paper, the BDS precise orbit determination results are obtained by using the IGS MGEX stations and the Chinese national reference stations,the accuracy of orbit determination of GEO, IGSO and MEO is 10.3cm, 2.8cm and 3.2cm, and the radial accuracy is 1.6cm,1.9cm and 1.5cm.The influence of ground reference stations distribution on BDS precise orbit determination is studied. The results show that the Chinese national reference stations contribute significantly to the BDS orbit determination, the overlap precision of GEO/IGSO/MEO satellites were improved by 15.5%, 57.5% and 5.3% respectively after adding the Chinese stations.Finally, the results of ODOP(orbit distribution of precision) and SLR are verified. Key words: BDS precise orbit determination; accuracy assessment;Chinese national reference stations;reference stations distribution;orbit distribution of precision
GTCBio's Precision Medicine Conference (July 7-8, 2016 - Boston, Massachusetts, USA).
Cole, P
2016-09-01
GTCBio's Precision Medicine Conference met this year to outline the many steps forward that precision medicine and individualized genomics has made and the challenges it still faces in technological, modeling, and standards development, interoperability and compatibility advancements, and methods of economic and societal adoption. The conference was split into four sections, 'Overcoming Challenges in the Commercialization of Precision Medicine', 'Implementation of Precision Medicine: Strategies & Technologies', 'Integrating & Interpreting Personal Genomics, Big Data, & Bioinformatics' and 'Incentivizing Precision Medicine: Regulation & Reimbursement', with this report focusing on the final two subjects. Copyright 2016 Prous Science, S.A.U. or its licensors. All rights reserved.
The Too-Much-Precision Effect.
Loschelder, David D; Friese, Malte; Schaerer, Michael; Galinsky, Adam D
2016-12-01
Past research has suggested a fundamental principle of price precision: The more precise an opening price, the more it anchors counteroffers. The present research challenges this principle by demonstrating a too-much-precision effect. Five experiments (involving 1,320 experts and amateurs in real-estate, jewelry, car, and human-resources negotiations) showed that increasing the precision of an opening offer had positive linear effects for amateurs but inverted-U-shaped effects for experts. Anchor precision backfired because experts saw too much precision as reflecting a lack of competence. This negative effect held unless first movers gave rationales that boosted experts' perception of their competence. Statistical mediation and experimental moderation established the critical role of competence attributions. This research disentangles competing theoretical accounts (attribution of competence vs. scale granularity) and qualifies two putative truisms: that anchors affect experts and amateurs equally, and that more precise prices are linearly more potent anchors. The results refine current theoretical understanding of anchoring and have significant implications for everyday life.
Toward precision medicine in Alzheimer's disease.
Reitz, Christiane
2016-03-01
In Western societies, Alzheimer's disease (AD) is the most common form of dementia and the sixth leading cause of death. In recent years, the concept of precision medicine, an approach for disease prevention and treatment that is personalized to an individual's specific pattern of genetic variability, environment and lifestyle factors, has emerged. While for some diseases, in particular select cancers and a few monogenetic disorders such as cystic fibrosis, significant advances in precision medicine have been made over the past years, for most other diseases precision medicine is only in its beginning. To advance the application of precision medicine to a wider spectrum of disorders, governments around the world are starting to launch Precision Medicine Initiatives, major efforts to generate the extensive scientific knowledge needed to integrate the model of precision medicine into every day clinical practice. In this article we summarize the state of precision medicine in AD, review major obstacles in its development, and discuss its benefits in this highly prevalent, clinically and pathologically complex disease.
Precision medicine in myasthenia graves: begin from the data precision
Hong, Yu; Xie, Yanchen; Hao, Hong-Jun; Sun, Ren-Cheng
2016-01-01
Myasthenia gravis (MG) is a prototypic autoimmune disease with overt clinical and immunological heterogeneity. The data of MG is far from individually precise now, partially due to the rarity and heterogeneity of this disease. In this review, we provide the basic insights of MG data precision, including onset age, presenting symptoms, generalization, thymus status, pathogenic autoantibodies, muscle involvement, severity and response to treatment based on references and our previous studies. Subgroups and quantitative traits of MG are discussed in the sense of data precision. The role of disease registries and scientific bases of precise analysis are also discussed to ensure better collection and analysis of MG data. PMID:27127759
Engineering and agronomy aspects of a long-term precision agriculture field experiment
USDA-ARS?s Scientific Manuscript database
Much research has been conducted on specific precision agriculture tools and implementation strategies, but little has been reported on long-term evaluation of integrated precision agriculture field experiments. In 2004 our research team developed and initiated a multi-faceted “precision agriculture...
Five critical elements to ensure the precision medicine.
Chen, Chengshui; He, Mingyan; Zhu, Yichun; Shi, Lin; Wang, Xiangdong
2015-06-01
The precision medicine as a new emerging area and therapeutic strategy has occurred and was practiced in the individual and brought unexpected successes, and gained high attentions from professional and social aspects as a new path to improve the treatment and prognosis of patients. There will be a number of new components to appear or be discovered, of which clinical bioinformatics integrates clinical phenotypes and informatics with bioinformatics, computational science, mathematics, and systems biology. In addition to those tools, precision medicine calls more accurate and repeatable methodologies for the identification and validation of gene discovery. Precision medicine will bring more new therapeutic strategies, drug discovery and development, and gene-oriented treatment. There is an urgent need to identify and validate disease-specific, mechanism-based, or epigenetics-dependent biomarkers to monitor precision medicine, and develop "precision" regulations to guard the application of precision medicine.
Using Precision in STEM Language: A Qualitative Look
ERIC Educational Resources Information Center
Capraro, Mary M.; Bicer, Ali; Grant, Melva R.; Lincoln, Yvonna S.
2017-01-01
Teachers need to develop a variety of pedagogical strategies that can encourage precise and accurate communication--an extremely important 21st century skill. Precision with STEM oral language is essential. Emphasizing oral communication with precise language in combination with increased spatial skills with modeling can improve the chances of…
Proceedings of the Workshop on Improvements to Photometry
NASA Technical Reports Server (NTRS)
Borucki, W. J. (Editor); Young, A. T. (Editor)
1984-01-01
The purposes of the workshop were to determine what astronomical problems would benefit by increased photometric precision, determine the current level of precision, identify the processes limiting the precision, and recommend approaches to improving photometric precision. Twenty representatives of the university, industry, and government communities participated. Results and recommendations are discussed.
Precision Medicine, Cardiovascular Disease and Hunting Elephants.
Joyner, Michael J
2016-01-01
Precision medicine postulates improved prediction, prevention, diagnosis and treatment of disease based on patient specific factors especially DNA sequence (i.e., gene) variants. Ideas related to precision medicine stem from the much anticipated "genetic revolution in medicine" arising seamlessly from the human genome project (HGP). In this essay I deconstruct the concept of precision medicine and raise questions about the validity of the paradigm in general and its application to cardiovascular disease. Thus far precision medicine has underperformed based on the vision promulgated by enthusiasts. While niche successes for precision medicine are likely, the promises of broad based transformation should be viewed with skepticism. Open discussion and debate related to precision medicine are urgently needed to avoid misapplication of resources, hype, iatrogenic interventions, and distraction from established approaches with ongoing utility. Failure to engage in such debate will lead to negative unintended consequences from a revolution that might never come. Copyright © 2016 Elsevier Inc. All rights reserved.
S-193 scatterometer backscattering cross section precision/accuracy for Skylab 2 and 3 missions
NASA Technical Reports Server (NTRS)
Krishen, K.; Pounds, D. J.
1975-01-01
Procedures for measuring the precision and accuracy with which the S-193 scatterometer measured the background cross section of ground scenes are described. Homogeneous ground sites were selected, and data from Skylab missions were analyzed. The precision was expressed as the standard deviation of the scatterometer-acquired backscattering cross section. In special cases, inference of the precision of measurement was made by considering the total range from the maximum to minimum of the backscatter measurements within a data segment, rather than the standard deviation. For Skylab 2 and 3 missions a precision better than 1.5 dB is indicated. This procedure indicates an accuracy of better than 3 dB for the Skylab 2 and 3 missions. The estimates of precision and accuracy given in this report are for backscattering cross sections from -28 to 18 dB. Outside this range the precision and accuracy decrease significantly.
Role of Imaging in the Era of Precision Medicine.
Giardino, Angela; Gupta, Supriya; Olson, Emmi; Sepulveda, Karla; Lenchik, Leon; Ivanidze, Jana; Rakow-Penner, Rebecca; Patel, Midhir J; Subramaniam, Rathan M; Ganeshan, Dhakshinamoorthy
2017-05-01
Precision medicine is an emerging approach for treating medical disorders, which takes into account individual variability in genetic and environmental factors. Preventive or therapeutic interventions can then be directed to those who will benefit most from targeted interventions, thereby maximizing benefits and minimizing costs and complications. Precision medicine is gaining increasing recognition by clinicians, healthcare systems, pharmaceutical companies, patients, and the government. Imaging plays a critical role in precision medicine including screening, early diagnosis, guiding treatment, evaluating response to therapy, and assessing likelihood of disease recurrence. The Association of University Radiologists Radiology Research Alliance Precision Imaging Task Force convened to explore the current and future role of imaging in the era of precision medicine and summarized its finding in this article. We review the increasingly important role of imaging in various oncological and non-oncological disorders. We also highlight the challenges for radiology in the era of precision medicine. Published by Elsevier Inc.
Why precision medicine is not the best route to a healthier world.
Rey-López, Juan Pablo; Sá, Thiago Herick de; Rezende, Leandro Fórnias Machado de
2018-02-05
Precision medicine has been announced as a new health revolution. The term precision implies more accuracy in healthcare and prevention of diseases, which could yield substantial cost savings. However, scientific debate about precision medicine is needed to avoid wasting economic resources and hype. In this commentary, we express the reasons why precision medicine cannot be a health revolution for population health. Advocates of precision medicine neglect the limitations of individual-centred, high-risk strategies (reduced population health impact) and the current crisis of evidence-based medicine. Overrated "precision medicine" promises may be serving vested interests, by dictating priorities in the research agenda and justifying the exorbitant healthcare expenditure in our finance-based medicine. If societies aspire to address strong risk factors for non-communicable diseases (such as air pollution, smoking, poor diets, or physical inactivity), they need less medicine and more investment in population prevention strategies.
Opportunities for the Cardiovascular Community in the Precision Medicine Initiative.
Shah, Svati H; Arnett, Donna; Houser, Steven R; Ginsburg, Geoffrey S; MacRae, Calum; Mital, Seema; Loscalzo, Joseph; Hall, Jennifer L
2016-01-12
The Precision Medicine Initiative recently announced by President Barack Obama seeks to move the field of precision medicine more rapidly into clinical care. Precision medicine revolves around the concept of integrating individual-level data including genomics, biomarkers, lifestyle and other environmental factors, wearable device physiological data, and information from electronic health records to ultimately provide better clinical care to individual patients. The Precision Medicine Initiative as currently structured will primarily fund efforts in cancer genomics with longer-term goals of advancing precision medicine to all areas of health, and will be supported through creation of a 1 million person cohort study across the United States. This focused effort on precision medicine provides scientists, clinicians, and patients within the cardiovascular community an opportunity to work together boldly to advance clinical care; the community needs to be aware and engaged in the process as it progresses. This article provides a framework for potential involvement of the cardiovascular community in the Precision Medicine Initiative, while highlighting significant challenges for its successful implementation. © 2016 American Heart Association, Inc.
rpe v5: an emulator for reduced floating-point precision in large numerical simulations
NASA Astrophysics Data System (ADS)
Dawson, Andrew; Düben, Peter D.
2017-06-01
This paper describes the rpe (reduced-precision emulator) library which has the capability to emulate the use of arbitrary reduced floating-point precision within large numerical models written in Fortran. The rpe software allows model developers to test how reduced floating-point precision affects the result of their simulations without having to make extensive code changes or port the model onto specialized hardware. The software can be used to identify parts of a program that are problematic for numerical precision and to guide changes to the program to allow a stronger reduction in precision.The development of rpe was motivated by the strong demand for more computing power. If numerical precision can be reduced for an application under consideration while still achieving results of acceptable quality, computational cost can be reduced, since a reduction in numerical precision may allow an increase in performance or a reduction in power consumption. For simulations with weather and climate models, savings due to a reduction in precision could be reinvested to allow model simulations at higher spatial resolution or complexity, or to increase the number of ensemble members to improve predictions. rpe was developed with a particular focus on the community of weather and climate modelling, but the software could be used with numerical simulations from other domains.
Ghasemi, Mojtaba; Nabipour, Iraj; Omrani, Abdolmajid; Alipour, Zeinab; Assadi, Majid
2016-01-01
This paper presents a review of the importance and role of precision medicine and molecular imaging technologies in cancer diagnosis with therapeutics and diagnostics purposes. Precision medicine is progressively becoming a hot topic in all disciplines related to biomedical investigation and has the capacity to become the paradigm for clinical practice. The future of medicine lies in early diagnosis and individually appropriate treatments, a concept that has been named precision medicine, i.e. delivering the right treatment to the right patient at the right time. Molecular imaging is quickly being recognized as a tool with the potential to ameliorate every aspect of cancer treatment. On the other hand, emerging high-throughput technologies such as omics techniques and systems approaches have generated a paradigm shift for biological systems in advanced life science research. In this review, we describe the precision medicine, difference between precision medicine and personalized medicine, precision medicine initiative, systems biology/medicine approaches (such as genomics, radiogenomics, transcriptomics, proteomics, and metabolomics), P4 medicine, relationship between systems biology/medicine approaches and precision medicine, and molecular imaging modalities and their utility in cancer treatment and diagnosis. Accordingly, the precision medicine and molecular imaging will enable us to accelerate and improve cancer management in future medicine.
Ghasemi, Mojtaba; Nabipour, Iraj; Omrani, Abdolmajid; Alipour, Zeinab; Assadi, Majid
2016-01-01
This paper presents a review of the importance and role of precision medicine and molecular imaging technologies in cancer diagnosis with therapeutics and diagnostics purposes. Precision medicine is progressively becoming a hot topic in all disciplines related to biomedical investigation and has the capacity to become the paradigm for clinical practice. The future of medicine lies in early diagnosis and individually appropriate treatments, a concept that has been named precision medicine, i.e. delivering the right treatment to the right patient at the right time. Molecular imaging is quickly being recognized as a tool with the potential to ameliorate every aspect of cancer treatment. On the other hand, emerging high-throughput technologies such as omics techniques and systems approaches have generated a paradigm shift for biological systems in advanced life science research. In this review, we describe the precision medicine, difference between precision medicine and personalized medicine, precision medicine initiative, systems biology/medicine approaches (such as genomics, radiogenomics, transcriptomics, proteomics, and metabolomics), P4 medicine, relationship between systems biology/medicine approaches and precision medicine, and molecular imaging modalities and their utility in cancer treatment and diagnosis. Accordingly, the precision medicine and molecular imaging will enable us to accelerate and improve cancer management in future medicine. PMID:28078184
NASA Astrophysics Data System (ADS)
Jing, Chao; Liu, Zhongling; Zhou, Ge; Zhang, Yimo
2011-11-01
The nanometer-level precise phase-shift system is designed to realize the phase-shift interferometry in electronic speckle shearography pattern interferometry. The PZT is used as driving component of phase-shift system and translation component of flexure hinge is developed to realize micro displacement of non-friction and non-clearance. Closed-loop control system is designed for high-precision micro displacement, in which embedded digital control system is developed for completing control algorithm and capacitive sensor is used as feedback part for measuring micro displacement in real time. Dynamic model and control model of the nanometer-level precise phase-shift system is analyzed, and high-precision micro displacement is realized with digital PID control algorithm on this basis. It is proved with experiments that the location precision of the precise phase-shift system to step signal of displacement is less than 2nm and the location precision to continuous signal of displacement is less than 5nm, which is satisfied with the request of the electronic speckle shearography and phase-shift pattern interferometry. The stripe images of four-step phase-shift interferometry and the final phase distributed image correlated with distortion of objects are listed in this paper to prove the validity of nanometer-level precise phase-shift system.
Precision medicine: In need of guidance and surveillance.
Lin, Jian-Zhen; Long, Jun-Yu; Wang, An-Qiang; Zheng, Ying; Zhao, Hai-Tao
2017-07-28
Precision medicine, currently a hotspot in mainstream medicine, has been strongly promoted in recent years. With rapid technological development, such as next-generation sequencing, and fierce competition in molecular targeted drug exploitation, precision medicine represents an advance in science and technology; it also fulfills needs in public health care. The clinical translation and application of precision medicine - especially in the prevention and treatment of tumors - is far from satisfactory; however, the aims of precision medicine deserve approval. Thus, this medical approach is currently in its infancy; it has promising prospects, but it needs to overcome numbers of problems and deficiencies. It is expected that in addition to conventional symptoms and signs, precision medicine will define disease in terms of the underlying molecular characteristics and other environmental susceptibility factors. Those expectations should be realized by constructing a novel data network, integrating clinical data from individual patients and personal genomic background with existing research on the molecular makeup of diseases. In addition, multi-omics analysis and multi-discipline collaboration will become crucial elements in precision medicine. Precision medicine deserves strong support, and its development demands directed momentum. We propose three kinds of impetus (research, application and collaboration impetus) for such directed momentum toward promoting precision medicine and accelerating its clinical translation and application.
Precision medicine: In need of guidance and surveillance
Lin, Jian-Zhen; Long, Jun-Yu; Wang, An-Qiang; Zheng, Ying; Zhao, Hai-Tao
2017-01-01
Precision medicine, currently a hotspot in mainstream medicine, has been strongly promoted in recent years. With rapid technological development, such as next-generation sequencing, and fierce competition in molecular targeted drug exploitation, precision medicine represents an advance in science and technology; it also fulfills needs in public health care. The clinical translation and application of precision medicine - especially in the prevention and treatment of tumors - is far from satisfactory; however, the aims of precision medicine deserve approval. Thus, this medical approach is currently in its infancy; it has promising prospects, but it needs to overcome numbers of problems and deficiencies. It is expected that in addition to conventional symptoms and signs, precision medicine will define disease in terms of the underlying molecular characteristics and other environmental susceptibility factors. Those expectations should be realized by constructing a novel data network, integrating clinical data from individual patients and personal genomic background with existing research on the molecular makeup of diseases. In addition, multi-omics analysis and multi-discipline collaboration will become crucial elements in precision medicine. Precision medicine deserves strong support, and its development demands directed momentum. We propose three kinds of impetus (research, application and collaboration impetus) for such directed momentum toward promoting precision medicine and accelerating its clinical translation and application. PMID:28811702
Wang, Shun-Yi; Chen, Xian-Xia; Li, Yi; Zhang, Yu-Ying
2016-12-20
The arrival of precision medicine plan brings new opportunities and challenges for patients undergoing precision diagnosis and treatment of malignant tumors. With the development of medical imaging, information on different modality imaging can be integrated and comprehensively analyzed by imaging fusion system. This review aimed to update the application of multimodality imaging fusion technology in the precise diagnosis and treatment of malignant tumors under the precision medicine plan. We introduced several multimodality imaging fusion technologies and their application to the diagnosis and treatment of malignant tumors in clinical practice. The data cited in this review were obtained mainly from the PubMed database from 1996 to 2016, using the keywords of "precision medicine", "fusion imaging", "multimodality", and "tumor diagnosis and treatment". Original articles, clinical practice, reviews, and other relevant literatures published in English were reviewed. Papers focusing on precision medicine, fusion imaging, multimodality, and tumor diagnosis and treatment were selected. Duplicated papers were excluded. Multimodality imaging fusion technology plays an important role in tumor diagnosis and treatment under the precision medicine plan, such as accurate location, qualitative diagnosis, tumor staging, treatment plan design, and real-time intraoperative monitoring. Multimodality imaging fusion systems could provide more imaging information of tumors from different dimensions and angles, thereby offing strong technical support for the implementation of precision oncology. Under the precision medicine plan, personalized treatment of tumors is a distinct possibility. We believe that multimodality imaging fusion technology will find an increasingly wide application in clinical practice.
ERIC Educational Resources Information Center
Edge, Brittani; Velandia, Margarita; Lambert, Dayton M.; Roberts, Roland K.; Larson, James A.; English, Burton C.; Boyer, Christopher; Rejesus, Roderick; Mishra, Ashok
2017-01-01
Using information from precision farmer surveys conducted in the southern United States in 2005 and 2013, we evaluated changes in the use of precision farming information sources among cotton producers. Although Extension remains an important source for producers interested in precision farming information, the percentage of cotton producers using…
Precise GPS ephemerides from DMA and NGS tested by time transfer
NASA Technical Reports Server (NTRS)
Lewandowski, Wlodzimierz W.; Petit, Gerard; Thomas, Claudine
1992-01-01
It was shown that the use of the Defense Mapping Agency's (DMA) precise ephemerides brings a significant improvement to the accuracy of GPS time transfer. At present a new set of precise ephemerides produced by the National Geodetic Survey (NGS) has been made available to the timing community. This study demonstrates that both types of precise ephemerides improve long-distance GPS time transfer and remove the effects of Selective Availability (SA) degradation of broadcast ephemerides. The issue of overcoming SA is also discussed in terms of the routine availability of precise ephemerides.
Mohan, Shalini V; Chang, Anne Lynn S
2014-06-01
Precision medicine and precision therapeutics is currently in its infancy with tremendous potential to improve patient care by better identifying individuals at risk for skin cancer and predict tumor responses to treatment. This review focuses on the Hedgehog signaling pathway, its critical role in the pathogenesis of basal cell carcinoma, and the emergence of targeted treatments for advanced basal cell carcinoma. Opportunities to utilize precision medicine are outlined, such as molecular profiling to predict basal cell carcinoma response to targeted therapy and to inform therapeutic decisions.
Ogden R. Lindsley and the historical development of precision teaching
Potts, Lisa; Eshleman, John W.; Cooper, John O.
1993-01-01
This paper presents the historical developments of precision teaching, a technological offshoot of radical behaviorism and free-operant conditioning. The sequence progresses from the scientific precursors of precision teaching and the beginnings of precision teaching to principal developments since 1965. Information about the persons, events, and accomplishments presented in this chronology was compiled in several ways. Journals, books, and conference presentations provided the essential information. The most important source for this account was Ogden Lindsley himself, because Lindsley and his students established the basic practices that define precision teaching. PMID:22478145
Attaining the Photometric Precision Required by Future Dark Energy Projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stubbs, Christopher
2013-01-21
This report outlines our progress towards achieving the high-precision astronomical measurements needed to derive improved constraints on the nature of the Dark Energy. Our approach to obtaining higher precision flux measurements has two basic components: 1) determination of the optical transmission of the atmosphere, and 2) mapping out the instrumental photon sensitivity function vs. wavelength, calibrated by referencing the measurements to the known sensitivity curve of a high precision silicon photodiode, and 3) using the self-consistency of the spectrum of stars to achieve precise color calibrations.
Precision medicine for nurses: 101.
Lemoine, Colleen
2014-05-01
To introduce the key concepts and terms associated with precision medicine and support understanding of future developments in the field by providing an overview and history of precision medicine, related ethical considerations, and nursing implications. Current nursing, medical and basic science literature. Rapid progress in understanding the oncogenic drivers associated with cancer is leading to a shift toward precision medicine, where treatment is based on targeting specific genetic and epigenetic alterations associated with a particular cancer. Nurses will need to embrace the paradigm shift to precision medicine, expend the effort necessary to learn the essential terminology, concepts and principles, and work collaboratively with physician colleagues to best position our patients to maximize the potential that precision medicine can offer. Copyright © 2014 Elsevier Inc. All rights reserved.
Review on the progress of ultra-precision machining technologies
NASA Astrophysics Data System (ADS)
Yuan, Julong; Lyu, Binghai; Hang, Wei; Deng, Qianfa
2017-06-01
Ultra-precision machining technologies are the essential methods, to obtain the highest form accuracy and surface quality. As more research findings are published, such technologies now involve complicated systems engineering and been widely used in the production of components in various aerospace, national defense, optics, mechanics, electronics, and other high-tech applications. The conception, applications and history of ultra-precision machining are introduced in this article, and the developments of ultra-precision machining technologies, especially ultra-precision grinding, ultra-precision cutting and polishing are also reviewed. The current state and problems of this field in China are analyzed. Finally, the development trends of this field and the coping strategies employed in China to keep up with the trends are discussed.
Routine Microsecond Molecular Dynamics Simulations with AMBER on GPUs. 1. Generalized Born
2012-01-01
We present an implementation of generalized Born implicit solvent all-atom classical molecular dynamics (MD) within the AMBER program package that runs entirely on CUDA enabled NVIDIA graphics processing units (GPUs). We discuss the algorithms that are used to exploit the processing power of the GPUs and show the performance that can be achieved in comparison to simulations on conventional CPU clusters. The implementation supports three different precision models in which the contributions to the forces are calculated in single precision floating point arithmetic but accumulated in double precision (SPDP), or everything is computed in single precision (SPSP) or double precision (DPDP). In addition to performance, we have focused on understanding the implications of the different precision models on the outcome of implicit solvent MD simulations. We show results for a range of tests including the accuracy of single point force evaluations and energy conservation as well as structural properties pertainining to protein dynamics. The numerical noise due to rounding errors within the SPSP precision model is sufficiently large to lead to an accumulation of errors which can result in unphysical trajectories for long time scale simulations. We recommend the use of the mixed-precision SPDP model since the numerical results obtained are comparable with those of the full double precision DPDP model and the reference double precision CPU implementation but at significantly reduced computational cost. Our implementation provides performance for GB simulations on a single desktop that is on par with, and in some cases exceeds, that of traditional supercomputers. PMID:22582031
Estimating maneuvers for precise relative orbit determination using GPS
NASA Astrophysics Data System (ADS)
Allende-Alba, Gerardo; Montenbruck, Oliver; Ardaens, Jean-Sébastien; Wermuth, Martin; Hugentobler, Urs
2017-01-01
Precise relative orbit determination is an essential element for the generation of science products from distributed instrumentation of formation flying satellites in low Earth orbit. According to the mission profile, the required formation is typically maintained and/or controlled by executing maneuvers. In order to generate consistent and precise orbit products, a strategy for maneuver handling is mandatory in order to avoid discontinuities or precision degradation before, after and during maneuver execution. Precise orbit determination offers the possibility of maneuver estimation in an adjustment of single-satellite trajectories using GPS measurements. However, a consistent formulation of a precise relative orbit determination scheme requires the implementation of a maneuver estimation strategy which can be used, in addition, to improve the precision of maneuver estimates by drawing upon the use of differential GPS measurements. The present study introduces a method for precise relative orbit determination based on a reduced-dynamic batch processing of differential GPS pseudorange and carrier phase measurements, which includes maneuver estimation as part of the relative orbit adjustment. The proposed method has been validated using flight data from space missions with different rates of maneuvering activity, including the GRACE, TanDEM-X and PRISMA missions. The results show the feasibility of obtaining precise relative orbits without degradation in the vicinity of maneuvers as well as improved maneuver estimates that can be used for better maneuver planning in flight dynamics operations.
Liu, Jen-Pei; Lu, Li-Tien; Liao, C T
2009-09-01
Intermediate precision is one of the most important characteristics for evaluation of precision in assay validation. The current methods for evaluation of within-device precision recommended by the Clinical Laboratory Standard Institute (CLSI) guideline EP5-A2 are based on the point estimator. On the other hand, in addition to point estimators, confidence intervals can provide a range for the within-device precision with a probability statement. Therefore, we suggest a confidence interval approach for assessment of the within-device precision. Furthermore, under the two-stage nested random-effects model recommended by the approved CLSI guideline EP5-A2, in addition to the current Satterthwaite's approximation and the modified large sample (MLS) methods, we apply the technique of generalized pivotal quantities (GPQ) to derive the confidence interval for the within-device precision. The data from the approved CLSI guideline EP5-A2 illustrate the applications of the confidence interval approach and comparison of results between the three methods. Results of a simulation study on the coverage probability and expected length of the three methods are reported. The proposed method of the GPQ-based confidence intervals is also extended to consider the between-laboratories variation for precision assessment.
LDPC decoder with a limited-precision FPGA-based floating-point multiplication coprocessor
NASA Astrophysics Data System (ADS)
Moberly, Raymond; O'Sullivan, Michael; Waheed, Khurram
2007-09-01
Implementing the sum-product algorithm, in an FPGA with an embedded processor, invites us to consider a tradeoff between computational precision and computational speed. The algorithm, known outside of the signal processing community as Pearl's belief propagation, is used for iterative soft-decision decoding of LDPC codes. We determined the feasibility of a coprocessor that will perform product computations. Our FPGA-based coprocessor (design) performs computer algebra with significantly less precision than the standard (e.g. integer, floating-point) operations of general purpose processors. Using synthesis, targeting a 3,168 LUT Xilinx FPGA, we show that key components of a decoder are feasible and that the full single-precision decoder could be constructed using a larger part. Soft-decision decoding by the iterative belief propagation algorithm is impacted both positively and negatively by a reduction in the precision of the computation. Reducing precision reduces the coding gain, but the limited-precision computation can operate faster. A proposed solution offers custom logic to perform computations with less precision, yet uses the floating-point format to interface with the software. Simulation results show the achievable coding gain. Synthesis results help theorize the the full capacity and performance of an FPGA-based coprocessor.
Garrido, P; Aldaz, A; Vera, R; Calleja, M A; de Álava, E; Martín, M; Matías-Guiu, X; Palacios, J
2018-04-01
Precision medicine is an emerging approach for disease treatment and prevention that takes into account individual variability in genes, environment, and lifestyle for each person. Precision medicine is transforming clinical and biomedical research, as well as health care itself from a conceptual, as well as a methodological viewpoint, providing extraordinary opportunities to improve public health and lower the costs of the healthcare system. However, the implementation of precision medicine poses ethical-legal, regulatory, organizational, and knowledge-related challenges. Without a national strategy, precision medicine, which will be implemented one way or another, could take place without the appropriate planning that can guarantee technical quality, equal access of all citizens to the best practices, violating the rights of patients and professionals, and jeopardizing the solvency of the healthcare system. With this paper from the Spanish Societies of Medical Oncology, Pathology, and Hospital Pharmacy, we highlight the need to institute a consensual national strategy for the development of precision medicine in our country, review the national and international context, comment on the opportunities and challenges for implementing precision medicine, and outline the objectives of a national strategy on precision medicine in cancer.
Method of high precision interval measurement in pulse laser ranging system
NASA Astrophysics Data System (ADS)
Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong
2013-09-01
Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.
Advanced bioanalytics for precision medicine.
Roda, Aldo; Michelini, Elisa; Caliceti, Cristiana; Guardigli, Massimo; Mirasoli, Mara; Simoni, Patrizia
2018-01-01
Precision medicine is a new paradigm that combines diagnostic, imaging, and analytical tools to produce accurate diagnoses and therapeutic interventions tailored to the individual patient. This approach stands in contrast to the traditional "one size fits all" concept, according to which researchers develop disease treatments and preventions for an "average" patient without considering individual differences. The "one size fits all" concept has led to many ineffective or inappropriate treatments, especially for pathologies such as Alzheimer's disease and cancer. Now, precision medicine is receiving massive funding in many countries, thanks to its social and economic potential in terms of improved disease prevention, diagnosis, and therapy. Bioanalytical chemistry is critical to precision medicine. This is because identifying an appropriate tailored therapy requires researchers to collect and analyze information on each patient's specific molecular biomarkers (e.g., proteins, nucleic acids, and metabolites). In other words, precision diagnostics is not possible without precise bioanalytical chemistry. This Trend article highlights some of the most recent advances, including massive analysis of multilayer omics, and new imaging technique applications suitable for implementing precision medicine. Graphical abstract Precision medicine combines bioanalytical chemistry, molecular diagnostics, and imaging tools for performing accurate diagnoses and selecting optimal therapies for each patient.
Design and control of the precise tracking bed based on complex electromechanical design theory
NASA Astrophysics Data System (ADS)
Ren, Changzhi; Liu, Zhao; Wu, Liao; Chen, Ken
2010-05-01
The precise tracking technology is wide used in astronomical instruments, satellite tracking and aeronautic test bed. However, the precise ultra low speed tracking drive system is one high integrated electromechanical system, which one complexly electromechanical design method is adopted to improve the efficiency, reliability and quality of the system during the design and manufacture circle. The precise Tracking Bed is one ultra-exact, ultra-low speed, high precision and huge inertial instrument, which some kind of mechanism and environment of the ultra low speed is different from general technology. This paper explores the design process based on complex electromechanical optimizing design theory, one non-PID with a CMAC forward feedback control method is used in the servo system of the precise tracking bed and some simulation results are discussed.
Precision medicine for psychopharmacology: a general introduction.
Shin, Cheolmin; Han, Changsu; Pae, Chi-Un; Patkar, Ashwin A
2016-07-01
Precision medicine is an emerging medical model that can provide accurate diagnoses and tailored therapeutic strategies for patients based on data pertaining to genes, microbiomes, environment, family history and lifestyle. Here, we provide basic information about precision medicine and newly introduced concepts, such as the precision medicine ecosystem and big data processing, and omics technologies including pharmacogenomics, pharamacometabolomics, pharmacoproteomics, pharmacoepigenomics, connectomics and exposomics. The authors review the current state of omics in psychiatry and the future direction of psychopharmacology as it moves towards precision medicine. Expert commentary: Advances in precision medicine have been facilitated by achievements in multiple fields, including large-scale biological databases, powerful methods for characterizing patients (such as genomics, proteomics, metabolomics, diverse cellular assays, and even social networks and mobile health technologies), and computer-based tools for analyzing large amounts of data.
Precision injection molding of freeform optics
NASA Astrophysics Data System (ADS)
Fang, Fengzhou; Zhang, Nan; Zhang, Xiaodong
2016-08-01
Precision injection molding is the most efficient mass production technology for manufacturing plastic optics. Applications of plastic optics in field of imaging, illumination, and concentration demonstrate a variety of complex surface forms, developing from conventional plano and spherical surfaces to aspheric and freeform surfaces. It requires high optical quality with high form accuracy and lower residual stresses, which challenges both optical tool inserts machining and precision injection molding process. The present paper reviews recent progress in mold tool machining and precision injection molding, with more emphasis on precision injection molding. The challenges and future development trend are also discussed.
Precision Medicine and PET/Computed Tomography: Challenges and Implementation.
Subramaniam, Rathan M
2017-01-01
Precision Medicine is about selecting the right therapy for the right patient, at the right time, specific to the molecular targets expressed by disease or tumors, in the context of patient's environment and lifestyle. Some of the challenges for delivery of precision medicine in oncology include biomarkers for patient selection for enrichment-precision diagnostics, mapping out tumor heterogeneity that contributes to therapy failures, and early therapy assessment to identify resistance to therapies. PET/computed tomography offers solutions in these important areas of challenges and facilitates implementation of precision medicine. Copyright © 2016 Elsevier Inc. All rights reserved.
Superior Intraparietal Sulcus Controls the Variability of Visual Working Memory Precision.
Galeano Weber, Elena M; Peters, Benjamin; Hahn, Tim; Bledowski, Christoph; Fiebach, Christian J
2016-05-18
Limitations of working memory (WM) capacity depend strongly on the cognitive resources that are available for maintaining WM contents in an activated state. Increasing the number of items to be maintained in WM was shown to reduce the precision of WM and to increase the variability of WM precision over time. Although WM precision was recently associated with neural codes particularly in early sensory cortex, we have so far no understanding of the neural bases underlying the variability of WM precision, and how WM precision is preserved under high load. To fill this gap, we combined human fMRI with computational modeling of behavioral performance in a delayed color-estimation WM task. Behavioral results replicate a reduction of WM precision and an increase of precision variability under high loads (5 > 3 > 1 colors). Load-dependent BOLD signals in primary visual cortex (V1) and superior intraparietal sulcus (IPS), measured during the WM task at 2-4 s after sample onset, were modulated by individual differences in load-related changes in the variability of WM precision. Although stronger load-related BOLD increase in superior IPS was related to lower increases in precision variability, thus stabilizing WM performance, the reverse was observed for V1. Finally, the detrimental effect of load on behavioral precision and precision variability was accompanied by a load-related decline in the accuracy of decoding the memory stimuli (colors) from left superior IPS. We suggest that the superior IPS may contribute to stabilizing visual WM performance by reducing the variability of memory precision in the face of higher load. This study investigates the neural bases of capacity limitations in visual working memory by combining fMRI with cognitive modeling of behavioral performance, in human participants. It provides evidence that the superior intraparietal sulcus (IPS) is a critical brain region that influences the variability of visual working memory precision between and within individuals (Fougnie et al., 2012; van den Berg et al., 2012) under increased memory load, possibly in cooperation with perceptual systems of the occipital cortex. These findings substantially extend our understanding of the nature of capacity limitations in visual working memory and their neural bases. Our work underlines the importance of integrating cognitive modeling with univariate and multivariate methods in fMRI research, thus improving our knowledge of brain-behavior relationships. Copyright © 2016 the authors 0270-6474/16/365623-13$15.00/0.
NASA Technical Reports Server (NTRS)
Spector, E.; LeBlanc, A.; Shackelford, L.
1995-01-01
This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lincoln, Don
The theory of quantum electrodynamics (QED) is perhaps the most precisely tested physics theory ever conceived. It describes the interaction of charged particles by emitting photons. The most precise prediction of this very precise theory is the magnetic strength of the electron, what physicists call the magnetic moment. Prediction and measurement agree to 12 digits of precision. In this video, Fermilab’s Dr. Don Lincoln talks about this amazing measurement.
ERIC Educational Resources Information Center
National Alliance of Business, Inc., Washington, DC.
CertainTeed's Precision Strike training program was designed to close the gaps between the current status of its workplace and where that work force needed to be to compete successfully in global markets. Precision Strike included Skills and Knowledge in Lifelong Learning (SKILL) customized, computerized lessons in basic skills, one-on-one…
Visser, Bart; De Looze, Michiel; De Graaff, Matthijs; Van Dieën, Jaap
2004-02-05
The objective of the present study was to gain insight into the effects of precision demands and mental pressure on the load of the upper extremity. Two computer mouse tasks were used: an aiming and a tracking task. Upper extremity loading was operationalized as the myo-electric activity of the wrist flexor and extensor and of the trapezius descendens muscles and the applied grip- and click-forces on the computer mouse. Performance measures, reflecting the accuracy in both tasks and the clicking rate in the aiming task, indicated that the levels of the independent variables resulted in distinguishable levels of accuracy and work pace. Precision demands had a small effect on upper extremity loading with a significant increase in the EMG-amplitudes (21%) of the wrist flexors during the aiming tasks. Precision had large effects on performance. Mental pressure had substantial effects on EMG-amplitudes with an increase of 22% in the trapezius when tracking and increases of 41% in the trapezius and 45% and 140% in the wrist extensors and flexors, respectively, when aiming. During aiming, grip- and click-forces increased by 51% and 40% respectively. Mental pressure had small effects on accuracy but large effects on tempo during aiming. Precision demands and mental pressure in aiming and tracking tasks with a computer mouse were found to coincide with increased muscle activity in some upper extremity muscles and increased force exertion on the computer mouse. Mental pressure caused significant effects on these parameters more often than precision demands. Precision and mental pressure were found to have effects on performance, with precision effects being significant for all performance measures studied and mental pressure effects for some of them. The results of this study suggest that precision demands and mental pressure increase upper extremity load, with mental pressure effects being larger than precision effects. The possible role of precision demands as an indirect mental stressor in working conditions is discussed.
van Heeswijk, Miriam M; Lambregts, Doenja M J; Maas, Monique; Lahaye, Max J; Ayas, Z; Slenter, Jos M G M; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H
2017-06-01
The apparent diffusion coefficient (ADC) is a potential prognostic imaging marker in rectal cancer. Typically, mean ADC values are used, derived from precise manual whole-volume tumor delineations by experts. The aim was first to explore whether non-precise circular delineation combined with histogram analysis can be a less cumbersome alternative to acquire similar ADC measurements and second to explore whether histogram analyses provide additional prognostic information. Thirty-seven patients who underwent a primary staging MRI including diffusion-weighted imaging (DWI; b0, 25, 50, 100, 500, 1000; 1.5 T) were included. Volumes-of-interest (VOIs) were drawn on b1000-DWI: (a) precise delineation, manually tracing tumor boundaries (2 expert readers), and (b) non-precise delineation, drawing circular VOIs with a wide margin around the tumor (2 non-experts). Mean ADC and histogram metrics (mean, min, max, median, SD, skewness, kurtosis, 5th-95th percentiles) were derived from the VOIs and delineation time was recorded. Measurements were compared between the two methods and correlated with prognostic outcome parameters. Median delineation time reduced from 47-165 s (precise) to 21-43 s (non-precise). The 45th percentile of the non-precise delineation showed the best correlation with the mean ADC from the precise delineation as the reference standard (ICC 0.71-0.75). None of the mean ADC or histogram parameters showed significant prognostic value; only the total tumor volume (VOI) was significantly larger in patients with positive clinical N stage and mesorectal fascia involvement. When performing non-precise tumor delineation, histogram analysis (in specific 45th ADC percentile) may be used as an alternative to obtain similar ADC values as with precise whole tumor delineation. Histogram analyses are not beneficial to obtain additional prognostic information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graczyk, Dariusz; Gieren, Wolfgang; Konorski, Piotr
In this study we investigate the calibration of surface brightness–color (SBC) relations based solely on eclipsing binary stars. We selected a sample of 35 detached eclipsing binaries with trigonometric parallaxes from Gaia DR1 or Hipparcos whose absolute dimensions are known with an accuracy better than 3% and that lie within 0.3 kpc from the Sun. For the purpose of this study, we used mostly homogeneous optical and near-infrared photometry based on the Tycho-2 and 2MASS catalogs. We derived geometric angular diameters for all stars in our sample with a precision better than 10%, and for 11 of them with amore » precision better than 2%. The precision of individual angular diameters of the eclipsing binary components is currently limited by the precision of the geometric distances (∼5% on average). However, by using a subsample of systems with the best agreement between their geometric and photometric distances, we derived the precise SBC relations based only on eclipsing binary stars. These relations have precisions that are comparable to the best available SBC relations based on interferometric angular diameters, and they are fully consistent with them. With very precise Gaia parallaxes becoming available in the near future, angular diameters with a precision better than 1% will be abundant. At that point, the main uncertainty in the total error budget of the SBC relations will come from transformations between different photometric systems, disentangling of component magnitudes, and for hot OB stars, the main uncertainty will come from the interstellar extinction determination. We argue that all these issues can be overcome with modern high-quality data and conclude that a precision better than 1% is entirely feasible.« less
The landscape of precision cancer medicine clinical trials in the United States.
Roper, Nitin; Stensland, Kristian D; Hendricks, Ryan; Galsky, Matthew D
2015-05-01
Advances in tumor biology and multiplex genomic analysis have ushered in the era of precision cancer medicine. Little is currently known, however, about the landscape of prospective "precision cancer medicine" clinical trials in the U.S. We identified all adult interventional cancer trials registered on ClinicalTrials.gov between September 2005 and May 2013. Trials were classified as "precision cancer medicine" if a genomic alteration in a predefined set of 88 genes was required for enrollment. Baseline characteristics were ascertained for each trial. Of the initial 18,797 trials identified, 9094 (48%) were eligible for inclusion: 684 (8%) were classified as precision cancer medicine trials and 8410 (92%) were non-precision cancer medicine trials. Compared with non-precision cancer medicine trials, precision cancer medicine trials were significantly more likely to be phase II [RR 1.19 (1.10-1.29), p<0.001], multi-center [RR 1.18 (1.11-1.26), p<0.001], open-label [RR 1.04 (1.02-1.07), p=0.005] and involve breast [RR 4.03 (3.49-4.52), p<0.001], colorectal [RR 1.62 (1.22-2.14), p=0.002] and skin [RR 1.98 (1.55-2.54), p<0.001] cancers. Precision medicine trials required 38 unique genomic alterations for enrollment. The proportion of precision cancer medicine trials compared to the total number of trials increased from 3% in 2006 to 16% in 2013. The proportion of adult cancer clinical trials in the U.S. requiring a genomic alteration for enrollment has increased substantially over the past several years. However, such trials still represent a small minority of studies performed within the cancer clinical trials enterprise and include a small subset of putatively "actionable" alterations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modeling and Positioning of a PZT Precision Drive System.
Liu, Che; Guo, Yanling
2017-11-08
The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD) is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK) was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.
Modeling and Positioning of a PZT Precision Drive System
Liu, Che; Guo, Yanling
2017-01-01
The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD) is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK) was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied. PMID:29117140
High-Precision Registration of Point Clouds Based on Sphere Feature Constraints.
Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter
2016-12-30
Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.
High-Precision Registration of Point Clouds Based on Sphere Feature Constraints
Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter
2016-01-01
Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method. PMID:28042846
[Implementation of precision control to achieve the goal of schistosomiasis elimination in China].
Zhou, Xiao-nong
2016-02-01
The integrated strategy for schistosomiasis control with focus on infectious source control, which has been implemented since 2004, accelerated the progress towards schistosomiasis control in China, and achieved transmission control of the disease across the country by the end of 2015, which achieved the overall objective of the Mid- and Long-term National Plan for Prevention and Control of Schistosomiasis (2004-2015) on schedule. Then, the goal of schistosomiasis elimination by 2025 was proposed in China in 2014. To achieve this new goal on schedule, we have to address the key issues, and implement precision control measures with more precise identification of control targets, so that we are able to completely eradicate the potential factors leading to resurgence of schistosomiasis transmission and enable the achievement of schistosomiasis elimination on schedule. Precision schistosomiasis control, a theoretical innovation of precision medicine in schistosomiasis control, will provide new insights into schistosomiasis control based on the conception of precision medicine. This paper describes the definition, interventions and the role of precision schistosomiasis control in the elimination of schistosomiasis in China, and demonstrates that sustainable improvement of professionals and integrated control capability at grass-root level is a prerequisite to the implementation of schistosomiasis control, precision schistosomiasis control is a key to the further implementation of the integrated strategy for schistosomiasis control with focus on infectious source control, and precision schistosomiasis control is a guarantee of curing schistosomiasis patients and implementing schistosomiasis control program and interventions.
NASA Astrophysics Data System (ADS)
Sánchez, Daniel; Kraus, F. Bernhard; Hernández, Manuel De Jesús; Vandame, Rémy
2007-07-01
Recruitment precision, i.e. the proportion of recruits that reach an advertised food source, is a crucial adaptation of social bees to their environment. Studies with honeybees showed that recruitment precision is not a fixed feature, but it may be enhanced by factors like experience and distance. However, little is known regarding the recruitment precision of stingless bees. Hence, in this study, we examined the effects of experience and spatial distance on the precision of the food communication system of the stingless bee Scaptotrigona mexicana. We conducted the experiments by training bees to a three-dimensional artificial patch at several distances from the colony. We recorded the choices of individual recruited foragers, either being newcomers (foragers without experience with the advertised food source) or experienced (foragers that had previously visited the feeder). We found that the average precision of newcomers (95.6 ± 2.61%) was significantly higher than that of experienced bees (80.2 ± 1.12%). While this might seem counter-intuitive on first sight, this “loss” of precision can be explained by the tendency of experienced recruits to explore nearby areas to find new rewarding food sources after they had initially learned the exact location of the food source. Increasing the distance from the colony had no significant effect on the precision of the foraging bees. Thus, our data show that experience, but not the distance of the food source, affected the patch precision of S. mexicana foragers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cleveland, Mathew A., E-mail: cleveland7@llnl.gov; Brunner, Thomas A.; Gentile, Nicholas A.
2013-10-15
We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositionsmore » will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.« less
Benschop, R; Draaisma, D
2000-01-01
A prominent feature of late nineteenth-century psychology was its intense preoccupation with precision. Precision was at once an ideal and an argument: the quest for precision helped psychology to establish its status as a mature science, sharing a characteristic concern with the natural sciences. We will analyse how psychologists set out to produce precision in 'mental chronometry', the measurement of the duration of psychological processes. In his Leipzig laboratory, Wundt inaugurated an elaborate research programme on mental chronometry. We will look at the problem of calibration of experimental apparatus and will describe the intricate material, literary, and social technologies involved in the manufacture of precision. First, we shall discuss some of the technical problems involved in the measurement of ever shorter time-spans. Next, the Cattell-Berger experiments will help us to argue against the received view that all the precision went into the hardware, and practically none into the social organization of experimentation. Experimenters made deliberate efforts to bring themselves and their subjects under a regime of control and calibration similar to that which reigned over the experimental machinery. In Leipzig psychology, the particular blend of material and social technology resulted in a specific object of study: the generalized mind. We will then show that the distribution of precision in experimental psychology outside Leipzig demanded a concerted effort of instruments, texts, and people. It will appear that the forceful attempts to produce precision and uniformity had some rather paradoxical consequences.
Problems, challenges and promises: perspectives on precision medicine.
Duffy, David J
2016-05-01
The 'precision medicine (systems medicine)' concept promises to achieve a shift to future healthcare systems with a more proactive and predictive approach to medicine, where the emphasis is on disease prevention rather than the treatment of symptoms. The individualization of treatment for each patient will be at the centre of this approach, with all of a patient's medical data being computationally integrated and accessible. Precision medicine is being rapidly embraced by biomedical researchers, pioneering clinicians and scientific funding programmes in both the European Union (EU) and USA. Precision medicine is a key component of both Horizon 2020 (the EU Framework Programme for Research and Innovation) and the White House's Precision Medicine Initiative. Precision medicine promises to revolutionize patient care and treatment decisions. However, the participants in precision medicine are faced with a considerable central challenge. Greater volumes of data from a wider variety of sources are being generated and analysed than ever before; yet, this heterogeneous information must be integrated and incorporated into personalized predictive models, the output of which must be intelligible to non-computationally trained clinicians. Drawing primarily from the field of 'oncology', this article will introduce key concepts and challenges of precision medicine and some of the approaches currently being implemented to overcome these challenges. Finally, this article also covers the criticisms of precision medicine overpromising on its potential to transform patient care. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Lincoln, Don
2018-01-16
The theory of quantum electrodynamics (QED) is perhaps the most precisely tested physics theory ever conceived. It describes the interaction of charged particles by emitting photons. The most precise prediction of this very precise theory is the magnetic strength of the electron, what physicists call the magnetic moment. Prediction and measurement agree to 12 digits of precision. In this video, Fermilabâs Dr. Don Lincoln talks about this amazing measurement.
A Dynamic Precision Evaluation Method for the Star Sensor in the Stellar-Inertial Navigation System.
Lu, Jiazhen; Lei, Chaohua; Yang, Yanqiang
2017-06-28
Integrating the advantages of INS (inertial navigation system) and the star sensor, the stellar-inertial navigation system has been used for a wide variety of applications. The star sensor is a high-precision attitude measurement instrument; therefore, determining how to validate its accuracy is critical in guaranteeing its practical precision. The dynamic precision evaluation of the star sensor is more difficult than a static precision evaluation because of dynamic reference values and other impacts. This paper proposes a dynamic precision verification method of star sensor with the aid of inertial navigation device to realize real-time attitude accuracy measurement. Based on the gold-standard reference generated by the star simulator, the altitude and azimuth angle errors of the star sensor are calculated for evaluation criteria. With the goal of diminishing the impacts of factors such as the sensors' drift and devices, the innovative aspect of this method is to employ static accuracy for comparison. If the dynamic results are as good as the static results, which have accuracy comparable to the single star sensor's precision, the practical precision of the star sensor is sufficiently high to meet the requirements of the system specification. The experiments demonstrate the feasibility and effectiveness of the proposed method.
Present situation and trend of precision guidance technology and its intelligence
NASA Astrophysics Data System (ADS)
Shang, Zhengguo; Liu, Tiandong
2017-11-01
This paper first introduces the basic concepts of precision guidance technology and artificial intelligence technology. Then gives a brief introduction of intelligent precision guidance technology, and with the help of development of intelligent weapon based on deep learning project in foreign: LRASM missile project, TRACE project, and BLADE project, this paper gives an overview of the current foreign precision guidance technology. Finally, the future development trend of intelligent precision guidance technology is summarized, mainly concentrated in the multi objectives, intelligent classification, weak target detection and recognition, intelligent between complex environment intelligent jamming and multi-source, multi missile cooperative fighting and other aspects.
Functional precision cancer medicine-moving beyond pure genomics.
Letai, Anthony
2017-09-08
The essential job of precision medicine is to match the right drugs to the right patients. In cancer, precision medicine has been nearly synonymous with genomics. However, sobering recent studies have generally shown that most patients with cancer who receive genomic testing do not benefit from a genomic precision medicine strategy. Although some call the entire project of precision cancer medicine into question, I suggest instead that the tools employed must be broadened. Instead of relying exclusively on big data measurements of initial conditions, we should also acquire highly actionable functional information by perturbing-for example, with cancer therapies-viable primary tumor cells from patients with cancer.
McInroy, John E.
2005-01-18
A precision positioning device is provided. The precision positioning device comprises a precision measuring/vibration isolation mechanism. A first plate is provided with the precision measuring mean secured to the first plate. A second plate is secured to the first plate. A third plate is secured to the second plate with the first plate being positioned between the second plate and the third plate. A fourth plate is secured to the third plate with the second plate being positioned between the third plate and the fourth plate. An adjusting mechanism for adjusting the position of the first plate, the second plate, the third plate, and the fourth plate relative to each other.
Probabilistic metrology or how some measurement outcomes render ultra-precise estimates
NASA Astrophysics Data System (ADS)
Calsamiglia, J.; Gendra, B.; Muñoz-Tapia, R.; Bagan, E.
2016-10-01
We show on theoretical grounds that, even in the presence of noise, probabilistic measurement strategies (which have a certain probability of failure or abstention) can provide, upon a heralded successful outcome, estimates with a precision that exceeds the deterministic bounds for the average precision. This establishes a new ultimate bound on the phase estimation precision of particular measurement outcomes (or sequence of outcomes). For probe systems subject to local dephasing, we quantify such precision limit as a function of the probability of failure that can be tolerated. Our results show that the possibility of abstaining can set back the detrimental effects of noise.
[Precision and personalized medicine].
Sipka, Sándor
2016-10-01
The author describes the concept of "personalized medicine" and the newly introduced "precision medicine". "Precision medicine" applies the terms of "phenotype", "endotype" and "biomarker" in order to characterize more precisely the various diseases. Using "biomarkers" the homogeneous type of a disease (a "phenotype") can be divided into subgroups called "endotypes" requiring different forms of treatment and financing. The good results of "precision medicine" have become especially apparent in relation with allergic and autoimmune diseases. The application of this new way of thinking is going to be necessary in Hungary, too, in the near future for participants, controllers and financing boards of healthcare. Orv. Hetil., 2016, 157(44), 1739-1741.
High precision applications of the global positioning system
NASA Technical Reports Server (NTRS)
Lichten, Stephen M.
1991-01-01
The Global Positioning System (GPS) is a constellation of U.S. defense navigation satellites which can be used for military and civilian positioning applications. A wide variety of GPS scientific applications were identified and precise positioning capabilities with GPS were already demonstrated with data available from the present partial satellite constellation. Expected applications include: measurements of Earth crustal motion, particularly in seismically active regions; measurements of the Earth's rotation rate and pole orientation; high-precision Earth orbiter tracking; surveying; measurements of media propagation delays for calibration of deep space radiometric data in support of NASA planetary missions; determination of precise ground station coordinates; and precise time transfer worldwide.
[Current situation and thoughts on precision medicine about the treatment of tumor in China].
Guo, J C; Yuan, D
2016-07-01
With United States starting"precision medical plan", it is widespread all over the world and opens a new direction to the development of medicine. Our country also starts the plan, trying to take the opportunity. At present, tumor threats human health with high incidence and mortality. In China, the incidence and mortality of tumor has been on the rise.So the tumor has become one of the most important fields of precision medicine.Precision medicine, hoping to reveal the Chinese characteristics of precision medicine, and getting the personal and social maximize health benefits are discussed in the paper.
Precision Medicine in Cancer Treatment
Precision medicine helps doctors select cancer treatments that are most likely to help patients based on a genetic understanding of their disease. Learn about the promise of precision medicine and the role it plays in cancer treatment.
Geographic variation in mimetic precision among different species of coral snake mimics.
Akcali, C K; Pfennig, D W
2017-07-01
Batesian mimicry is widespread, but whether and why different species of mimics vary geographically in resemblance to their model is unclear. We characterized geographic variation in mimetic precision among four Batesian mimics of coral snakes. Each mimic occurs where its model is abundant (i.e. in 'deep sympatry'), rare (i.e. at the sympatry/allopatry boundary or 'edge sympatry') and absent (i.e. in allopatry). Geographic variation in mimetic precision was qualitatively different among these mimics. In one mimic, the most precise individuals occurred in edge sympatry; in another, they occurred in deep sympatry; in the third, they occurred in allopatry; and in the fourth, precise mimics were not concentrated anywhere throughout their range. Mimicry was less precise in allopatry than in sympatry in only two mimics. We present several nonmutually exclusive hypotheses for these patterns. Generally, examining geographic variation in mimetic precision - within and among different mimics - offers novel insights into the causes and consequences of mimicry. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.
NASA Technical Reports Server (NTRS)
Lemoine, Frank G.; Zelensky, Nikita P.; Chinn, Douglas S.; Beckley, Brian D.; Lillibridge, John L.
2006-01-01
The US Navy's GEOSAT Follow-On spacecraft (GFO) primary mission objective is to map the oceans using a radar altimeter. Satellite laser ranging data, especially in combination with altimeter crossover data, offer the only means of determining high-quality precise orbits. Two tuned gravity models, PGS7727 and PGS7777b, were created at NASA GSFC for GFO that reduce the predicted radial orbit through degree 70 to 13.7 and 10.0 mm. A macromodel was developed to model the nonconservative forces and the SLR spacecraft measurement offset was adjusted to remove a mean bias. Using these improved models, satellite-ranging data, altimeter crossover data, and Doppler data are used to compute both daily medium precision orbits with a latency of less than 24 hours. Final precise orbits are also computed using these tracking data and exported with a latency of three to four weeks to NOAA for use on the GFO Geophysical Data Records (GDR s). The estimated orbit precision of the daily orbits is between 10 and 20 cm, whereas the precise orbits have a precision of 5 cm.
A real-time surface inspection system for precision steel balls based on machine vision
NASA Astrophysics Data System (ADS)
Chen, Yi-Ji; Tsai, Jhy-Cherng; Hsu, Ya-Chen
2016-07-01
Precision steel balls are one of the most fundament components for motion and power transmission parts and they are widely used in industrial machinery and the automotive industry. As precision balls are crucial for the quality of these products, there is an urgent need to develop a fast and robust system for inspecting defects of precision steel balls. In this paper, a real-time system for inspecting surface defects of precision steel balls is developed based on machine vision. The developed system integrates a dual-lighting system, an unfolding mechanism and inspection algorithms for real-time signal processing and defect detection. The developed system is tested under feeding speeds of 4 pcs s-1 with a detection rate of 99.94% and an error rate of 0.10%. The minimum detectable surface flaw area is 0.01 mm2, which meets the requirement for inspecting ISO grade 100 precision steel balls.
Precision and repeatability of the Optotrak 3020 motion measurement system.
States, R A; Pappas, E
2006-01-01
Several motion analysis systems are used by researchers to quantify human motion and to perform accurate surgical procedures. The Optotrak 3020 is one of these systems and despite its widespread use there is not any published information on its precision and repeatability. We used a repeated measures design study to evaluate the precision and repeatability of the Optotrak 3020 by measuring distance and angle in three sessions, four distances and three conditions (motion, static vertical, and static tilted). Precision and repeatability were found to be excellent for both angle and distance although they decreased with increasing distance from the sensors and with tilt from the plane of the sensors. Motion did not have a significant effect on the precision of the measurements. In conclusion, the measurement error of the Optotrak is minimal. Further studies are needed to evaluate its precision and repeatability under human motion conditions.
Direction information in multiple object tracking is limited by a graded resource.
Horowitz, Todd S; Cohen, Michael A
2010-10-01
Is multiple object tracking (MOT) limited by a fixed set of structures (slots), a limited but divisible resource, or both? Here, we answer this question by measuring the precision of the direction representation for tracked targets. The signature of a limited resource is a decrease in precision as the square root of the tracking load. The signature of fixed slots is a fixed precision. Hybrid models predict a rapid decrease to asymptotic precision. In two experiments, observers tracked moving disks and reported target motion direction by adjusting a probe arrow. We derived the precision of representation of correctly tracked targets using a mixture distribution analysis. Precision declined with target load according to the square-root law up to six targets. This finding is inconsistent with both pure and hybrid slot models. Instead, directional information in MOT appears to be limited by a continuously divisible resource.
NASA Astrophysics Data System (ADS)
Qian, Elaine A.; Wixtrom, Alex I.; Axtell, Jonathan C.; Saebi, Azin; Jung, Dahee; Rehak, Pavel; Han, Yanxiao; Moully, Elamar Hakim; Mosallaei, Daniel; Chow, Sylvia; Messina, Marco S.; Wang, Jing Yang; Royappa, A. Timothy; Rheingold, Arnold L.; Maynard, Heather D.; Král, Petr; Spokoyny, Alexander M.
2017-04-01
The majority of biomolecules are intrinsically atomically precise, an important characteristic that enables rational engineering of their recognition and binding properties. However, imparting a similar precision to hybrid nanoparticles has been challenging because of the inherent limitations of existing chemical methods and building blocks. Here we report a new approach to form atomically precise and highly tunable hybrid nanomolecules with well-defined three-dimensionality. Perfunctionalization of atomically precise clusters with pentafluoroaryl-terminated linkers produces size-tunable rigid cluster nanomolecules. These species are amenable to facile modification with a variety of thiol-containing molecules and macromolecules. Assembly proceeds at room temperature within hours under mild conditions, and the resulting nanomolecules exhibit high stabilities because of their full covalency. We further demonstrate how these nanomolecules grafted with saccharides can exhibit dramatically improved binding affinity towards a protein. Ultimately, the developed strategy allows the rapid generation of precise molecular assemblies to investigate multivalent interactions.
An Astronomical Test of CCD Photometric Precision
NASA Technical Reports Server (NTRS)
Koch, David G.; Dunham, Edward W.; Borucki, William J.; Jenkins, Jon M.
2001-01-01
Ground-based differential photometry is limited to a precision of order 10(exp -3) because of atmospheric effects. A space-based photometer should be limited only by the inherent instrument precision and shot noise. Laboratory tests have shown that a precision of order 10-5 is achievable with commercially available charged coupled devices (CCDs). We have proposed to take this one step further by performing measurements at a telescope using a Wollaston prism as a beam splitter First-order atmospheric effects (e.g., extinction) will appear to be identical in the two images of each star formed by the prism and will be removed in the data analysis. This arrangement can determine the precision that is achievable under the influence of second-order atmospheric effects (e.g., variable point-spread function (PSF) from seeing). These telescopic observations will thus provide a lower limit to the precision that can be realized by a space-based differential photometer.
Atomically Precise Interfaces from Non-stoichiometric Deposition
NASA Astrophysics Data System (ADS)
Nie, Yuefeng; Zhu, Ye; Lee, Che-Hui; Kourkoutis, Lena; Mundy, Julia; Junquera, Javier; Ghosez, Philippe; Baek, David; Sung, Suk Hyun; Xi, Xiaoxing; Shen, Kyle; Muller, David; Schlom, Darrell
2015-03-01
Complex oxide heterostructures display some of the most chemically abrupt, atomically precise interfaces, which is advantageous when constructing new interface phases with emergent properties by juxtaposing incompatible ground states. One might assume that atomically precise interfaces result from stoichiometric growth. Here we show that the most precise control is, however, obtained by using deliberate and specific non-stoichiometric growth conditions. For the precise growth of Srn+1TinO3n+1 Ruddlesden-Popper (RP) phases, stoichiometric deposition leads to the loss of the first RP rock-salt double layer, but growing with a strontium-rich surface layer restores the bulk stoichiometry and ordering of the subsurface RP structure. Our results dramatically expand the materials that can be prepared in epitaxial heterostructures with precise interface control--from just the n = 1 end members (perovskites) to the entire RP homologous series--enabling the exploration of novel quantum phenomena at a richer variety of oxide interfaces.
Atomically precise interfaces from non-stoichiometric deposition
NASA Astrophysics Data System (ADS)
Nie, Y. F.; Zhu, Y.; Lee, C.-H.; Kourkoutis, L. F.; Mundy, J. A.; Junquera, J.; Ghosez, Ph.; Baek, D. J.; Sung, S.; Xi, X. X.; Shen, K. M.; Muller, D. A.; Schlom, D. G.
2014-08-01
Complex oxide heterostructures display some of the most chemically abrupt, atomically precise interfaces, which is advantageous when constructing new interface phases with emergent properties by juxtaposing incompatible ground states. One might assume that atomically precise interfaces result from stoichiometric growth. Here we show that the most precise control is, however, obtained by using deliberate and specific non-stoichiometric growth conditions. For the precise growth of Srn+1TinOn+1 Ruddlesden-Popper (RP) phases, stoichiometric deposition leads to the loss of the first RP rock-salt double layer, but growing with a strontium-rich surface layer restores the bulk stoichiometry and ordering of the subsurface RP structure. Our results dramatically expand the materials that can be prepared in epitaxial heterostructures with precise interface control—from just the n=∞ end members (perovskites) to the entire RP homologous series—enabling the exploration of novel quantum phenomena at a richer variety of oxide interfaces.
NASA Technical Reports Server (NTRS)
Allton, J. H.
2017-01-01
There is widespread agreement among planetary scientists that much of what we know about the workings of the solar system comes from accurate, high precision measurements on returned samples. Precision is a function of the number of atoms the instrumentation is able to count. Accuracy depends on the calibration or standardization technique. For Genesis, the solar wind sample return mission, acquiring enough atoms to ensure precise SW measurements and then accurately quantifying those measurements were steps known to be non-trivial pre-flight. The difficulty of precise and accurate measurements on returned samples, and why they cannot be made remotely, is not communicated well to the public. In part, this is be-cause "high precision" is abstract and error bars are not very exciting topics. This paper explores ideas for collecting and compiling compelling metaphors and colorful examples as a resource for planetary science public speakers.
Effect of Correlated Precision Errors on Uncertainty of a Subsonic Venturi Calibration
NASA Technical Reports Server (NTRS)
Hudson, S. T.; Bordelon, W. J., Jr.; Coleman, H. W.
1996-01-01
An uncertainty analysis performed in conjunction with the calibration of a subsonic venturi for use in a turbine test facility produced some unanticipated results that may have a significant impact in a variety of test situations. Precision uncertainty estimates using the preferred propagation techniques in the applicable American National Standards Institute/American Society of Mechanical Engineers standards were an order of magnitude larger than precision uncertainty estimates calculated directly from a sample of results (discharge coefficient) obtained at the same experimental set point. The differences were attributable to the effect of correlated precision errors, which previously have been considered negligible. An analysis explaining this phenomenon is presented. The article is not meant to document the venturi calibration, but rather to give a real example of results where correlated precision terms are important. The significance of the correlated precision terms could apply to many test situations.
Zhou, Li; Wang, Kui; Li, Qifu; Nice, Edouard C; Zhang, Haiyuan; Huang, Canhua
2016-01-01
Cancer is a common disease that is a leading cause of death worldwide. Currently, early detection and novel therapeutic strategies are urgently needed for more effective management of cancer. Importantly, protein profiling using clinical proteomic strategies, with spectacular sensitivity and precision, offer excellent promise for the identification of potential biomarkers that would direct the development of targeted therapeutic anticancer drugs for precision medicine. In particular, clinical sample sources, including tumor tissues and body fluids (blood, feces, urine and saliva), have been widely investigated using modern high-throughput mass spectrometry-based proteomic approaches combined with bioinformatic analysis, to pursue the possibilities of precision medicine for targeted cancer therapy. Discussed in this review are the current advantages and limitations of clinical proteomics, the available strategies of clinical proteomics for the management of precision medicine, as well as the challenges and future perspectives of clinical proteomics-driven precision medicine for targeted cancer therapy.
Note: High precision measurements using high frequency gigahertz signals
NASA Astrophysics Data System (ADS)
Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung
2014-12-01
Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.
NASA Astrophysics Data System (ADS)
Monna, F.; Loizeau, J.-L.; Thomas, B. A.; Guéguen, C.; Favarger, P.-Y.
1998-08-01
One of the factors limiting the precision of inductively coupled plasma mass spectrometry is the counting statistics, which depend upon acquisition time and ion fluxes. In the present study, the precision of the isotopic measurements of Pb and Sr is examined. The time of measurement is optimally shared for each isotope, using a mathematical simulation, to provide the lowest theoretical analytical error. Different algorithms of mass bias correction are also taken into account and evaluated in term of improvement of overall precision. Several experiments allow a comparison of real conditions with theory. The present method significantly improves the precision, regardless of the instrument used. However, this benefit is more important for equipment which originally yields a precision close to that predicted by counting statistics. Additionally, the procedure is flexible enough to be easily adapted to other problems, such as isotopic dilution.
Yang, Xiao-Xing; Critchley, Lester A; Joynt, Gavin M
2011-01-01
Thermodilution cardiac output using a pulmonary artery catheter is the reference method against which all new methods of cardiac output measurement are judged. However, thermodilution lacks precision and has a quoted precision error of ± 20%. There is uncertainty about its true precision and this causes difficulty when validating new cardiac output technology. Our aim in this investigation was to determine the current precision error of thermodilution measurements. A test rig through which water circulated at different constant rates with ports to insert catheters into a flow chamber was assembled. Flow rate was measured by an externally placed transonic flowprobe and meter. The meter was calibrated by timed filling of a cylinder. Arrow and Edwards 7Fr thermodilution catheters, connected to a Siemens SC9000 cardiac output monitor, were tested. Thermodilution readings were made by injecting 5 mL of ice-cold water. Precision error was divided into random and systematic components, which were determined separately. Between-readings (random) variability was determined for each catheter by taking sets of 10 readings at different flow rates. Coefficient of variation (CV) was calculated for each set and averaged. Between-catheter systems (systematic) variability was derived by plotting calibration lines for sets of catheters. Slopes were used to estimate the systematic component. Performances of 3 cardiac output monitors were compared: Siemens SC9000, Siemens Sirecust 1261, and Philips MP50. Five Arrow and 5 Edwards catheters were tested using the Siemens SC9000 monitor. Flow rates between 0.7 and 7.0 L/min were studied. The CV (random error) for Arrow was 5.4% and for Edwards was 4.8%. The random precision error was ± 10.0% (95% confidence limits). CV (systematic error) was 5.8% and 6.0%, respectively. The systematic precision error was ± 11.6%. The total precision error of a single thermodilution reading was ± 15.3% and ± 13.0% for triplicate readings. Precision error increased by 45% when using the Sirecust monitor and 100% when using the Philips monitor. In vitro testing of pulmonary artery catheters enabled us to measure both the random and systematic error components of thermodilution cardiac output measurement, and thus calculate the precision error. Using the Siemens monitor, we established a precision error of ± 15.3% for single and ± 13.0% for triplicate reading, which was similar to the previous estimate of ± 20%. However, this precision error was significantly worsened by using the Sirecust and Philips monitors. Clinicians should recognize that the precision error of thermodilution cardiac output is dependent on the selection of catheter and monitor model.
Tian, Chao; Wang, Lixin; Novick, Kimberly A
2016-10-15
High-precision analysis of atmospheric water vapor isotope compositions, especially δ(17) O values, can be used to improve our understanding of multiple hydrological and meteorological processes (e.g., differentiate equilibrium or kinetic fractionation). This study focused on assessing, for the first time, how the accuracy and precision of vapor δ(17) O laser spectroscopy measurements depend on vapor concentration, delta range, and averaging-time. A Triple Water Vapor Isotope Analyzer (T-WVIA) was used to evaluate the accuracy and precision of δ(2) H, δ(18) O and δ(17) O measurements. The sensitivity of accuracy and precision to water vapor concentration was evaluated using two international standards (GISP and SLAP2). The sensitivity of precision to delta value was evaluated using four working standards spanning a large delta range. The sensitivity of precision to averaging-time was assessed by measuring one standard continuously for 24 hours. Overall, the accuracy and precision of the δ(2) H, δ(18) O and δ(17) O measurements were high. Across all vapor concentrations, the accuracy of δ(2) H, δ(18) O and δ(17) O observations ranged from 0.10‰ to 1.84‰, 0.08‰ to 0.86‰ and 0.06‰ to 0.62‰, respectively, and the precision ranged from 0.099‰ to 0.430‰, 0.009‰ to 0.080‰ and 0.022‰ to 0.054‰, respectively. The accuracy and precision of all isotope measurements were sensitive to concentration, with the higher accuracy and precision generally observed under moderate vapor concentrations (i.e., 10000-15000 ppm) for all isotopes. The precision was also sensitive to the range of delta values, although the effect was not as large compared with the sensitivity to concentration. The precision was much less sensitive to averaging-time than the concentration and delta range effects. The accuracy and precision performance of the T-WVIA depend on concentration but depend less on the delta value and averaging-time. The instrument can simultaneously and continuously measure δ(2) H, δ(18) O and δ(17) O values in water vapor, opening a new window to better understand ecological, hydrological and meteorological processes. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Franzen, Delwen L; Gleiss, Sarah A; Berger, Christina; Kümpfbeck, Franziska S; Ammer, Julian J; Felmy, Felix
2015-01-15
Passive and active membrane properties determine the voltage responses of neurons. Within the auditory brain stem, refinements in these intrinsic properties during late postnatal development usually generate short integration times and precise action-potential generation. This developmentally acquired temporal precision is crucial for auditory signal processing. How the interactions of these intrinsic properties develop in concert to enable auditory neurons to transfer information with high temporal precision has not yet been elucidated in detail. Here, we show how the developmental interaction of intrinsic membrane parameters generates high firing precision. We performed in vitro recordings from neurons of postnatal days 9-28 in the ventral nucleus of the lateral lemniscus of Mongolian gerbils, an auditory brain stem structure that converts excitatory to inhibitory information with high temporal precision. During this developmental period, the input resistance and capacitance decrease, and action potentials acquire faster kinetics and enhanced precision. Depending on the stimulation time course, the input resistance and capacitance contribute differentially to action-potential thresholds. The decrease in input resistance, however, is sufficient to explain the enhanced action-potential precision. Alterations in passive membrane properties also interact with a developmental change in potassium currents to generate the emergence of the mature firing pattern, characteristic of coincidence-detector neurons. Cholinergic receptor-mediated depolarizations further modulate this intrinsic excitability profile by eliciting changes in the threshold and firing pattern, irrespective of the developmental stage. Thus our findings reveal how intrinsic membrane properties interact developmentally to promote temporally precise information processing. Copyright © 2015 the American Physiological Society.
On the use of programmable hardware and reduced numerical precision in earth-system modeling.
Düben, Peter D; Russell, Francis P; Niu, Xinyu; Luk, Wayne; Palmer, T N
2015-09-01
Programmable hardware, in particular Field Programmable Gate Arrays (FPGAs), promises a significant increase in computational performance for simulations in geophysical fluid dynamics compared with CPUs of similar power consumption. FPGAs allow adjusting the representation of floating-point numbers to specific application needs. We analyze the performance-precision trade-off on FPGA hardware for the two-scale Lorenz '95 model. We scale the size of this toy model to that of a high-performance computing application in order to make meaningful performance tests. We identify the minimal level of precision at which changes in model results are not significant compared with a maximal precision version of the model and find that this level is very similar for cases where the model is integrated for very short or long intervals. It is therefore a useful approach to investigate model errors due to rounding errors for very short simulations (e.g., 50 time steps) to obtain a range for the level of precision that can be used in expensive long-term simulations. We also show that an approach to reduce precision with increasing forecast time, when model errors are already accumulated, is very promising. We show that a speed-up of 1.9 times is possible in comparison to FPGA simulations in single precision if precision is reduced with no strong change in model error. The single-precision FPGA setup shows a speed-up of 2.8 times in comparison to our model implementation on two 6-core CPUs for large model setups.
A path to precision in the ICU.
Maslove, David M; Lamontagne, Francois; Marshall, John C; Heyland, Daren K
2017-04-03
Precision medicine is increasingly touted as a groundbreaking new paradigm in biomedicine. In the ICU, the complexity and ambiguity of critical illness syndromes have been identified as fundamental justifications for the adoption of a precision approach to research and practice. Inherently protean diseases states such as sepsis and acute respiratory distress syndrome have manifestations that are physiologically and anatomically diffuse, and that fluctuate over short periods of time. This leads to considerable heterogeneity among patients, and conditions in which a "one size fits all" approach to therapy can lead to widely divergent results. Current ICU therapy can thus be seen as imprecise, with the potential to realize substantial gains from the adoption of precision medicine approaches. A number of challenges still face the development and adoption of precision critical care, a transition that may occur incrementally rather than wholesale. This article describes a few concrete approaches to addressing these challenges.First, novel clinical trial designs, including registry randomized controlled trials and platform trials, suggest ways in which conventional trials can be adapted to better accommodate the physiologic heterogeneity of critical illness. Second, beyond the "omics" technologies already synonymous with precision medicine, the data-rich environment of the ICU can generate complex physiologic signatures that could fuel precision-minded research and practice. Third, the role of computing infrastructure and modern informatics methods will be central to the pursuit of precision medicine in the ICU, necessitating close collaboration with data scientists. As work toward precision critical care continues, small proof-of-concept studies may prove useful in highlighting the potential of this approach.
Public health and precision medicine share a goal.
Vaithinathan, Asokan G; Asokan, Vanitha
2017-05-01
The advances made in genomics and molecular tools aid public health programs in the investigation of outbreaks and control of diseases by taking advantage of the precision medicine. Precision medicine means "segregating the individuals into subpopulations who vary in their disease susceptibility and response to a precise treatment" and not merely designing of drugs or creation of medical devices. By 2017, the United Kingdom 100,000 Genomes Project is expected to sequence 100,000 genomes from 70,000 patients. Similarly, the Precision Medicine Initiative of the United States plans to increase population-based genome sequencing and link it with clinical data. A national cohort of around 1 million people is to be established in the long term, to investigate the genetic and environmental determinants of health and disease, and further integrated to their electronic health records that are optional. Precision public health can be seen as administering the right intervention to the needy population at an appropriate time. Precision medicine originates from a wet-lab while evidence-based medicine is nurtured in a clinic. Linking the quintessential basic science research and clinical practice is necessary. In addition, new technologies to employ and analyze data in an integrated and dynamic way are essential for public health and precision medicine. The transition from evidence-based approach in public health to genomic approach to individuals with a paradigm shift of a "reactive" medicine to a more "proactive" and personalized health care may sound exceptional. However, a population perspective is needed for the precision medicine to succeed. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.
Subcortical Control of Precision Grip after Human Spinal Cord Injury
Bunday, Karen L.; Tazoe, Toshiki; Rothwell, John C.
2014-01-01
The motor cortex and the corticospinal system contribute to the control of a precision grip between the thumb and index finger. The involvement of subcortical pathways during human precision grip remains unclear. Using noninvasive cortical and cervicomedullary stimulation, we examined motor evoked potentials (MEPs) and the activity in intracortical and subcortical pathways targeting an intrinsic hand muscle when grasping a small (6 mm) cylinder between the thumb and index finger and during index finger abduction in uninjured humans and in patients with subcortical damage due to incomplete cervical spinal cord injury (SCI). We demonstrate that cortical and cervicomedullary MEP size was reduced during precision grip compared with index finger abduction in uninjured humans, but was unchanged in SCI patients. Regardless of whether cortical and cervicomedullary stimulation was used, suppression of the MEP was only evident 1–3 ms after its onset. Long-term (∼5 years) use of the GABAb receptor agonist baclofen by SCI patients reduced MEP size during precision grip to similar levels as uninjured humans. Index finger sensory function correlated with MEP size during precision grip in SCI patients. Intracortical inhibition decreased during precision grip and spinal motoneuron excitability remained unchanged in all groups. Our results demonstrate that the control of precision grip in humans involves premotoneuronal subcortical mechanisms, likely disynaptic or polysynaptic spinal pathways that are lacking after SCI and restored by long-term use of baclofen. We propose that spinal GABAb-ergic interneuronal circuits, which are sensitive to baclofen, are part of the subcortical premotoneuronal network shaping corticospinal output during human precision grip. PMID:24849366
Overcoming gaps and bottlenecks to advance precision agriculture
USDA-ARS?s Scientific Manuscript database
Maintaining a clear understanding of the technology gaps, knowledge needs, and training bottlenecks is required for improving adoption of precision agriculture. As an industry, precision agriculture embraces tools, methods, and practices that are constantly changing, requiring industry, education, a...
Assembling Precise Truss Structures With Minimal Stresses
NASA Technical Reports Server (NTRS)
Sword, Lee F.
1996-01-01
Improved method of assembling precise truss structures involves use of simple devices. Tapered pins that fit in tapered holes indicate deviations from prescribed lengths. Method both helps to ensure precision of finished structures and minimizes residual stresses within structures.
Using hyperspectral data in precision farming applications
USDA-ARS?s Scientific Manuscript database
Precision farming practices such as variable rate applications of fertilizer and agricultural chemicals require accurate field variability mapping. This chapter investigated the value of hyperspectral remote sensing in providing useful information for five applications of precision farming: (a) Soil...
System precisely controls oscillation of vibrating mass
NASA Technical Reports Server (NTRS)
Hancock, D. J.
1967-01-01
System precisely controls the sinusoidal amplitude of a vibrating mechanical mass. Using two sets of coils, the system regulates the drive signal amplitude at the precise level to maintain the mechanical mass when it reaches the desired vibration amplitude.
Last Glacial Maximum Salinity Reconstruction
NASA Astrophysics Data System (ADS)
Homola, K.; Spivack, A. J.
2016-12-01
It has been previously demonstrated that salinity can be reconstructed from sediment porewater. The goal of our study is to reconstruct high precision salinity during the Last Glacial Maximum (LGM). Salinity is usually determined at high precision via conductivity, which requires a larger volume of water than can be extracted from a sediment core, or via chloride titration, which yields lower than ideal precision. It has been demonstrated for water column samples that high precision density measurements can be used to determine salinity at the precision of a conductivity measurement using the equation of state of seawater. However, water column seawater has a relatively constant composition, in contrast to porewater, where variations from standard seawater composition occur. These deviations, which affect the equation of state, must be corrected for through precise measurements of each ion's concentration and knowledge of apparent partial molar density in seawater. We have developed a density-based method for determining porewater salinity that requires only 5 mL of sample, achieving density precisions of 10-6 g/mL. We have applied this method to porewater samples extracted from long cores collected along a N-S transect across the western North Atlantic (R/V Knorr cruise KN223). Density was determined to a precision of 2.3x10-6 g/mL, which translates to salinity uncertainty of 0.002 gms/kg if the effect of differences in composition is well constrained. Concentrations of anions (Cl-, and SO4-2) and cations (Na+, Mg+, Ca+2, and K+) were measured. To correct salinities at the precision required to unravel LGM Meridional Overturning Circulation, our ion precisions must be better than 0.1% for SO4-/Cl- and Mg+/Na+, and 0.4% for Ca+/Na+, and K+/Na+. Alkalinity, pH and Dissolved Inorganic Carbon of the porewater were determined to precisions better than 4% when ratioed to Cl-, and used to calculate HCO3-, and CO3-2. Apparent partial molar densities in seawater were determined experimentally. We compare the high precision salinity profiles determined using our new method to profiles determined from the traditional chloride titrations of parallel samples. Our technique provides a more accurate reconstruction of past salinity, informing questions of water mass composition and distribution during the LGM.
AMCP Partnership Forum: Managing Care in the Wave of Precision Medicine.
2018-05-23
Precision medicine, the customization of health care to an individual's genetic profile while accounting for biomarkers and lifestyle, has increasingly been adopted by health care stakeholders to guide the development of treatment options, improve treatment decision making, provide more patient-centered care, and better inform coverage and reimbursement decisions. Despite these benefits, key challenges prevent its broader use and adoption. On December 7-8, 2017, the Academy of Managed Care Pharmacy convened a group of stakeholders to discuss these challenges and provide recommendations to facilitate broader adoption and use of precision medicine across health care settings. These stakeholders represented the pharmaceutical industry, clinicians, patient advocacy, private payers, device manufacturers, health analytics, information technology, academia, and government agencies. Throughout the 2-day forum, participants discussed evidence requirements for precision medicine, including consistent ways to measure the utility and validity of precision medicine tests and therapies, limitations of traditional clinical trial designs, and limitations of value assessment framework methods. They also highlighted the challenges with evidence collection and data silos in precision medicine. Interoperability within and across health systems is hindering clinical advancements. Current medical coding systems also cannot account for the heterogeneity of many diseases, preventing health systems from having a complete understanding of their patient population to inform resource allocation. Challenges faced by payers, such as evidence limitations, to inform coverage and reimbursement decisions in precision medicine, as well as legal and regulatory barriers that inhibit more widespread data sharing, were also identified. While a broad range of perspectives was shared throughout the forum, participants reached consensus across 2 overarching areas. First, there is a greater need for common definitions, thresholds, and standards to guide evidence generation in precision medicine. Second, current information silos are preventing the sharing of valuable data. Collaboration among stakeholders is needed to support better information sharing, awareness, and education of precision medicine for patients. The recommendations brought forward by this diverse group of experts provide a set of solutions to spur widespread use and application of precision medicine. Taken together, successful adoption and use of precision medicine will require input and collaboration from all sectors of health care, especially patients. DISCLOSURES This AMCP Partnership Forum and the development of the proceedings document were supported by Amgen, Foundation Medicine, Genentech, Gilead, MedImpact, National Pharmaceutical Council, Precision for Value, Sanofi, Takeda, and Xcenda.
Mazzarella, Luca
2018-01-01
On 8 and 9 February 2018, the IFOM-IEO campus in Milan hosted the Milan summit on Precision Medicine, which gathered clinical and translational research experts from academia, industry and regulatory bodies to discuss the state of the art of precision medicine in Europe. The meeting was pervaded by a generalised feeling of excitement for a field that is perceived to be technologically mature for the transition into clinical routine but still hampered by numerous obstacles of a methodological, ethical, regulatory and possibly cultural nature. Through lively discussions, the attendees tried to identify realistic ways to implement a technology-rich precision approach to cancer patients.
Epistemology, Ethics, and Progress in Precision Medicine.
Hey, Spencer Phillips; Barsanti-Innes, Brianna
2016-01-01
The emerging paradigm of precision medicine strives to leverage the tools of molecular biology to prospectively tailor treatments to the individual patient. Fundamental to the success of this movement is the discovery and validation of "predictive biomarkers," which are properties of a patient's biological specimens that can be assayed in advance of therapy to inform the treatment decision. Unfortunately, research into biomarkers and diagnostics for precision medicine has fallen well short of expectations. In this essay, we examine the portfolio of research activities into the excision repair cross complement group 1 (ERCC1) gene as a predictive biomarker for precision lung cancer therapy as a case study in elucidating the epistemological and ethical obstacles to developing new precision medicines.
Precision engineering: an evolutionary perspective.
Evans, Chris J
2012-08-28
Precision engineering is a relatively new name for a technology with roots going back over a thousand years; those roots span astronomy, metrology, fundamental standards, manufacturing and money-making (literally). Throughout that history, precision engineers have created links across disparate disciplines to generate innovative responses to society's needs and wants. This review combines historical and technological perspectives to illuminate precision engineering's current character and directions. It first provides us a working definition of precision engineering and then reviews the subject's roots. Examples will be given showing the contributions of the technology to society, while simultaneously showing the creative tension between the technological convergence that spurs new directions and the vertical disintegration that optimizes manufacturing economics.
S193 radiometer brightness temperature precision/accuracy for SL2 and SL3
NASA Technical Reports Server (NTRS)
Pounds, D. J.; Krishen, K.
1975-01-01
The precision and accuracy with which the S193 radiometer measured the brightness temperature of ground scenes is investigated. Estimates were derived from data collected during Skylab missions. Homogeneous ground sites were selected and S193 radiometer brightness temperature data analyzed. The precision was expressed as the standard deviation of the radiometer acquired brightness temperature. Precision was determined to be 2.40 K or better depending on mode and target temperature.
Precision Machining Application and Technology: An Overview and Perspective.
1983-08-24
diamond turning lathes are being used to produce computer discs. Bryant Symons, an English firm, has reported diamond turning an aluminum computer disk at...34 Precision Engineering, Vol. 5(2), Guildford, Engl nd, July 1983. Watt, G., " Lathe for Generation of Spherical -arfaces of Revolution," given to Optical...Precision CNC Diamond Turning Machine," Annuals of the CIRP, Vol. 31/1, p 409, 1982. 8. Bryant Simmons Product Brochur-, "Ultra Precision Oiamond Turning
Biomarkers: Delivering on the expectation of molecularly driven, quantitative health.
Wilson, Jennifer L; Altman, Russ B
2018-02-01
Biomarkers are the pillars of precision medicine and are delivering on expectations of molecular, quantitative health. These features have made clinical decisions more precise and personalized, but require a high bar for validation. Biomarkers have improved health outcomes in a few areas such as cancer, pharmacogenetics, and safety. Burgeoning big data research infrastructure, the internet of things, and increased patient participation will accelerate discovery in the many areas that have not yet realized the full potential of biomarkers for precision health. Here we review themes of biomarker discovery, current implementations of biomarkers for precision health, and future opportunities and challenges for biomarker discovery. Impact statement Precision medicine evolved because of the understanding that human disease is molecularly driven and is highly variable across patients. This understanding has made biomarkers, a diverse class of biological measurements, more relevant for disease diagnosis, monitoring, and selection of treatment strategy. Biomarkers' impact on precision medicine can be seen in cancer, pharmacogenomics, and safety. The successes in these cases suggest many more applications for biomarkers and a greater impact for precision medicine across the spectrum of human disease. The authors assess the status of biomarker-guided medical practice by analyzing themes for biomarker discovery, reviewing the impact of these markers in the clinic, and highlight future and ongoing challenges for biomarker discovery. This work is timely and relevant, as the molecular, quantitative approach of precision medicine is spreading to many disease indications.
Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying
NASA Technical Reports Server (NTRS)
Calhoun, Philip; Novo-Gradac, Anne-Marie; Shah, Neerav
2017-01-01
Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing precision dual spacecraft formation flying to enable a virtual space telescope. Using precision dual spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts with spacecraft separations from 1000 km to 25,000 km, such as the Milli-Arc-Second Structure Imager (MASSIM) and the New Worlds Observer, and Heliophysics concepts for solar coronagraphs and X-ray imaging with smaller separations (50m-500m). All of these proposed missions require advances in guidance, navigation, and control (GNC) for precision formation flying. In particular, very precise astrometric alignment control and estimation is required for precise inertial pointing of the virtual space telescope to enable science imaging orders of magnitude better than can be achieved with conventional single spacecraft instruments. This work develops design architectures, algorithms, and performance analysis of proposed GNC systems for precision dual spacecraft astrometric alignment. These systems employ a variety of GNC sensors and actuators, including laser-based alignment and ranging systems, optical imaging sensors (e.g. guide star telescope), inertial measurement units (IMU), as well as microthruster and precision stabilized platforms. A comprehensive GNC performance analysis is given for Heliophysics dual spacecraft PFF imaging mission concept.
Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying
NASA Technical Reports Server (NTRS)
Calhoun, Philip C.; Novo-Gradac, Anne-Marie; Shah, Neerav
2017-01-01
Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing precision dual spacecraft formation flying to enable a virtual space telescope. Using precision dual spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts with spacecraft separations from 1000 km to 25,000 km, such as the Milli-Arc-Second Structure Imager (MASSIM) and the New Worlds Observer, and Heliophysics concepts for solar coronagraphs and X-ray imaging with smaller separations (50m 500m). All of these proposed missions require advances in guidance, navigation, and control (GNC) for precision formation flying. In particular, very precise astrometric alignment control and estimation is required for precise inertial pointing of the virtual space telescope to enable science imaging orders of magnitude better than can be achieved with conventional single spacecraft instruments. This work develops design architectures, algorithms, and performance analysis of proposed GNC systems for precision dual spacecraft astrometric alignment. These systems employ a variety of GNC sensors and actuators, including laser-based alignment and ranging systems, optical imaging sensors (e.g. guide star telescope), inertial measurement units (IMU), as well as micro-thruster and precision stabilized platforms. A comprehensive GNC performance analysis is given for Heliophysics dual spacecraft PFF imaging mission concept.
Does precision decrease with set size?
Mazyar, Helga; van den Berg, Ronald; Ma, Wei Ji
2012-01-01
The brain encodes visual information with limited precision. Contradictory evidence exists as to whether the precision with which an item is encoded depends on the number of stimuli in a display (set size). Some studies have found evidence that precision decreases with set size, but others have reported constant precision. These groups of studies differed in two ways. The studies that reported a decrease used displays with heterogeneous stimuli and tasks with a short-term memory component, while the ones that reported constancy used homogeneous stimuli and tasks that did not require short-term memory. To disentangle the effects of heterogeneity and short-memory involvement, we conducted two main experiments. In Experiment 1, stimuli were heterogeneous, and we compared a condition in which target identity was revealed before the stimulus display with one in which it was revealed afterward. In Experiment 2, target identity was fixed, and we compared heterogeneous and homogeneous distractor conditions. In both experiments, we compared an optimal-observer model in which precision is constant with set size with one in which it depends on set size. We found that precision decreases with set size when the distractors are heterogeneous, regardless of whether short-term memory is involved, but not when it is homogeneous. This suggests that heterogeneity, not short-term memory, is the critical factor. In addition, we found that precision exhibits variability across items and trials, which may partly be caused by attentional fluctuations. PMID:22685337
Garrido, Pilar; Aldaz, Azucena; Calleja, Miguel Ángel; De Álava, Enrique; Lamas, María Jesús; Martín, Miguel; Matías-Guiu, Xavier; Palacios, José; Vera, Ruth
2017-11-01
Precision medicine is an emerging approach for disease treatment and prevention that takes into account individual variability in genes, environment, and lifestyle for each person. Precision medicine is transforming clinical and biomedical research, as well as health care itself from a conceptual, as well as a methodological viewpoint, providing extraordinary opportunities to improve public health and lower the costs of the healthcare system. However, the implementation of precision medicine poses ethical-legal, regulatory, organizational and knowledge-related challenges. Without a national strategy, precision medicine, which will be implemented one way or another, could take place without the appropriate planning that can guarantee technical quality, equal access of all citizens to the best practices, violating the rights of patients and professionals and jeopardizing the solvency of the healthcare system. With this paper from the Spanish Societies of Medical Oncology (SEOM), Pathology (SEAP), and Hospital Pharmacy (SEFH) we highlight the need to institute a consensual national strategy for the development of precision medicine in our country, review the national and international context, comment on the opportunities and challenges for implementing precision medicine, and outline the objectives of a national strategy on precision medicine in cancer. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Quantifying the Precision of Single-Molecule Torque and Twist Measurements Using Allan Variance.
van Oene, Maarten M; Ha, Seungkyu; Jager, Tessa; Lee, Mina; Pedaci, Francesco; Lipfert, Jan; Dekker, Nynke H
2018-04-24
Single-molecule manipulation techniques have provided unprecedented insights into the structure, function, interactions, and mechanical properties of biological macromolecules. Recently, the single-molecule toolbox has been expanded by techniques that enable measurements of rotation and torque, such as the optical torque wrench (OTW) and several different implementations of magnetic (torque) tweezers. Although systematic analyses of the position and force precision of single-molecule techniques have attracted considerable attention, their angle and torque precision have been treated in much less detail. Here, we propose Allan deviation as a tool to systematically quantitate angle and torque precision in single-molecule measurements. We apply the Allan variance method to experimental data from our implementations of (electro)magnetic torque tweezers and an OTW and find that both approaches can achieve a torque precision better than 1 pN · nm. The OTW, capable of measuring torque on (sub)millisecond timescales, provides the best torque precision for measurement times ≲10 s, after which drift becomes a limiting factor. For longer measurement times, magnetic torque tweezers with their superior stability provide the best torque precision. Use of the Allan deviation enables critical assessments of the torque precision as a function of measurement time across different measurement modalities and provides a tool to optimize measurement protocols for a given instrument and application. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Gene mutation-based and specific therapies in precision medicine.
Wang, Xiangdong
2016-04-01
Precision medicine has been initiated and gains more and more attention from preclinical and clinical scientists. A number of key elements or critical parts in precision medicine have been described and emphasized to establish a systems understanding of precision medicine. The principle of precision medicine is to treat patients on the basis of genetic alterations after gene mutations are identified, although questions and challenges still remain before clinical application. Therapeutic strategies of precision medicine should be considered according to gene mutation, after biological and functional mechanisms of mutated gene expression or epigenetics, or the correspondent protein, are clearly validated. It is time to explore and develop a strategy to target and correct mutated genes by direct elimination, restoration, correction or repair of mutated sequences/genes. Nevertheless, there are still numerous challenges to integrating widespread genomic testing into individual cancer therapies and into decision making for one or another treatment. There are wide-ranging and complex issues to be solved before precision medicine becomes clinical reality. Thus, the precision medicine can be considered as an extension and part of clinical and translational medicine, a new alternative of clinical therapies and strategies, and have an important impact on disease cures and patient prognoses. © 2015 The Author. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
NASA Astrophysics Data System (ADS)
Ren, Xia; Yang, Yuanxi; Zhu, Jun; Xu, Tianhe
2017-11-01
Intersatellite Link (ISL) technology helps to realize the auto update of broadcast ephemeris and clock error parameters for Global Navigation Satellite System (GNSS). ISL constitutes an important approach with which to both improve the observation geometry and extend the tracking coverage of China's Beidou Navigation Satellite System (BDS). However, ISL-only orbit determination might lead to the constellation drift, rotation, and even lead to the divergence in orbit determination. Fortunately, predicted orbits with good precision can be used as a priori information with which to constrain the estimated satellite orbit parameters. Therefore, the precision of satellite autonomous orbit determination can be improved by consideration of a priori orbit information, and vice versa. However, the errors of rotation and translation in a priori orbit will remain in the ultimate result. This paper proposes a constrained precise orbit determination (POD) method for a sub-constellation of the new Beidou satellite constellation with only a few ISLs. The observation model of dual one-way measurements eliminating satellite clock errors is presented, and the orbit determination precision is analyzed with different data processing backgrounds. The conclusions are as follows. (1) With ISLs, the estimated parameters are strongly correlated, especially the positions and velocities of satellites. (2) The performance of determined BDS orbits will be improved by the constraints with more precise priori orbits. The POD precision is better than 45 m with a priori orbit constrain of 100 m precision (e.g., predicted orbits by telemetry tracking and control system), and is better than 6 m with precise priori orbit constraints of 10 m precision (e.g., predicted orbits by international GNSS monitoring & Assessment System (iGMAS)). (3) The POD precision is improved by additional ISLs. Constrained by a priori iGMAS orbits, the POD precision with two, three, and four ISLs is better than 6, 3, and 2 m, respectively. (4) The in-plane link and out-of-plane link have different contributions to observation configuration and system observability. The POD with weak observation configuration (e.g., one in-plane link and one out-of-plane link) should be tightly constrained with a priori orbits.
NASA Astrophysics Data System (ADS)
Zender, Charles S.
2016-09-01
Geoscientific models and measurements generate false precision (scientifically meaningless data bits) that wastes storage space. False precision can mislead (by implying noise is signal) and be scientifically pointless, especially for measurements. By contrast, lossy compression can be both economical (save space) and heuristic (clarify data limitations) without compromising the scientific integrity of data. Data quantization can thus be appropriate regardless of whether space limitations are a concern. We introduce, implement, and characterize a new lossy compression scheme suitable for IEEE floating-point data. Our new Bit Grooming algorithm alternately shaves (to zero) and sets (to one) the least significant bits of consecutive values to preserve a desired precision. This is a symmetric, two-sided variant of an algorithm sometimes called Bit Shaving that quantizes values solely by zeroing bits. Our variation eliminates the artificial low bias produced by always zeroing bits, and makes Bit Grooming more suitable for arrays and multi-dimensional fields whose mean statistics are important. Bit Grooming relies on standard lossless compression to achieve the actual reduction in storage space, so we tested Bit Grooming by applying the DEFLATE compression algorithm to bit-groomed and full-precision climate data stored in netCDF3, netCDF4, HDF4, and HDF5 formats. Bit Grooming reduces the storage space required by initially uncompressed and compressed climate data by 25-80 and 5-65 %, respectively, for single-precision values (the most common case for climate data) quantized to retain 1-5 decimal digits of precision. The potential reduction is greater for double-precision datasets. When used aggressively (i.e., preserving only 1-2 digits), Bit Grooming produces storage reductions comparable to other quantization techniques such as Linear Packing. Unlike Linear Packing, whose guaranteed precision rapidly degrades within the relatively narrow dynamic range of values that it can compress, Bit Grooming guarantees the specified precision throughout the full floating-point range. Data quantization by Bit Grooming is irreversible (i.e., lossy) yet transparent, meaning that no extra processing is required by data users/readers. Hence Bit Grooming can easily reduce data storage volume without sacrificing scientific precision or imposing extra burdens on users.
The Use of Scale-Dependent Precision to Increase Forecast Accuracy in Earth System Modelling
NASA Astrophysics Data System (ADS)
Thornes, Tobias; Duben, Peter; Palmer, Tim
2016-04-01
At the current pace of development, it may be decades before the 'exa-scale' computers needed to resolve individual convective clouds in weather and climate models become available to forecasters, and such machines will incur very high power demands. But the resolution could be improved today by switching to more efficient, 'inexact' hardware with which variables can be represented in 'reduced precision'. Currently, all numbers in our models are represented as double-precision floating points - each requiring 64 bits of memory - to minimise rounding errors, regardless of spatial scale. Yet observational and modelling constraints mean that values of atmospheric variables are inevitably known less precisely on smaller scales, suggesting that this may be a waste of computer resources. More accurate forecasts might therefore be obtained by taking a scale-selective approach whereby the precision of variables is gradually decreased at smaller spatial scales to optimise the overall efficiency of the model. To study the effect of reducing precision to different levels on multiple spatial scales, we here introduce a new model atmosphere developed by extending the Lorenz '96 idealised system to encompass three tiers of variables - which represent large-, medium- and small-scale features - for the first time. In this chaotic but computationally tractable system, the 'true' state can be defined by explicitly resolving all three tiers. The abilities of low resolution (single-tier) double-precision models and similar-cost high resolution (two-tier) models in mixed-precision to produce accurate forecasts of this 'truth' are compared. The high resolution models outperform the low resolution ones even when small-scale variables are resolved in half-precision (16 bits). This suggests that using scale-dependent levels of precision in more complicated real-world Earth System models could allow forecasts to be made at higher resolution and with improved accuracy. If adopted, this new paradigm would represent a revolution in numerical modelling that could be of great benefit to the world.
Error analysis of high-rate GNSS precise point positioning for seismic wave measurement
NASA Astrophysics Data System (ADS)
Shu, Yuanming; Shi, Yun; Xu, Peiliang; Niu, Xiaoji; Liu, Jingnan
2017-06-01
High-rate GNSS precise point positioning (PPP) has been playing a more and more important role in providing precise positioning information in fast time-varying environments. Although kinematic PPP is commonly known to have a precision of a few centimeters, the precision of high-rate PPP within a short period of time has been reported recently with experiments to reach a few millimeters in the horizontal components and sub-centimeters in the vertical component to measure seismic motion, which is several times better than the conventional kinematic PPP practice. To fully understand the mechanism of mystified excellent performance of high-rate PPP within a short period of time, we have carried out a theoretical error analysis of PPP and conducted the corresponding simulations within a short period of time. The theoretical analysis has clearly indicated that the high-rate PPP errors consist of two types: the residual systematic errors at the starting epoch, which affect high-rate PPP through the change of satellite geometry, and the time-varying systematic errors between the starting epoch and the current epoch. Both the theoretical error analysis and simulated results are fully consistent with and thus have unambiguously confirmed the reported high precision of high-rate PPP, which has been further affirmed here by the real data experiments, indicating that high-rate PPP can indeed achieve the millimeter level of precision in the horizontal components and the sub-centimeter level of precision in the vertical component to measure motion within a short period of time. The simulation results have clearly shown that the random noise of carrier phases and higher order ionospheric errors are two major factors to affect the precision of high-rate PPP within a short period of time. The experiments with real data have also indicated that the precision of PPP solutions can degrade to the cm level in both the horizontal and vertical components, if the geometry of satellites is rather poor with a large DOP value.
Bonaretti, Serena; Vilayphiou, Nicolas; Chan, Caroline Mai; Yu, Andrew; Nishiyama, Kyle; Liu, Danmei; Boutroy, Stephanie; Ghasem-Zadeh, Ali; Boyd, Steven K.; Chapurlat, Roland; McKay, Heather; Shane, Elizabeth; Bouxsein, Mary L.; Black, Dennis M.; Majumdar, Sharmila; Orwoll, Eric S.; Lang, Thomas F.; Khosla, Sundeep; Burghardt, Andrew J.
2017-01-01
Introduction HR-pQCT is increasingly used to assess bone quality, fracture risk and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection (“scout view image”) and define the region to be scanned by positioning a “reference line” on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. Methods To evaluate the operator in vivo measurement precision we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner’s software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled 6 new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. Results In vivo precision errors were up to three-fold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. Inter-operator precision errors were significantly greater than short-term intra-operator precision (p<0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators, and lower inter-operator reproducibility (p<0.001). Precision errors were significantly greater for the radius than for the tibia. Conclusion Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online (http://webapps.radiology.ucsf.edu/refline/). PMID:27475931
The economic case for precision medicine.
Gavan, Sean P; Thompson, Alexander J; Payne, Katherine
2018-01-01
Introduction : The advancement of precision medicine into routine clinical practice has been highlighted as an agenda for national and international health care policy. A principle barrier to this advancement is in meeting requirements of the payer or reimbursement agency for health care. This special report aims to explain the economic case for precision medicine, by accounting for the explicit objectives defined by decision-makers responsible for the allocation of limited health care resources. Areas covered : The framework of cost-effectiveness analysis, a method of economic evaluation, is used to describe how precision medicine can, in theory, exploit identifiable patient-level heterogeneity to improve population health outcomes and the relative cost-effectiveness of health care. Four case studies are used to illustrate potential challenges when demonstrating the economic case for a precision medicine in practice. Expert commentary : The economic case for a precision medicine should be considered at an early stage during its research and development phase. Clinical and economic evidence can be generated iteratively and should be in alignment with the objectives and requirements of decision-makers. Programmes of further research, to demonstrate the economic case of a precision medicine, can be prioritized by the extent that they reduce the uncertainty expressed by decision-makers.
Platform Precision Autopilot Overview and Mission Performance
NASA Technical Reports Server (NTRS)
Strovers, Brian K.; Lee, James A.
2009-01-01
The Platform Precision Autopilot is an instrument landing system-interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Unmanned Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.
Platform Precision Autopilot Overview and Flight Test Results
NASA Technical Reports Server (NTRS)
Lin, V.; Strovers, B.; Lee, J.; Beck, R.
2008-01-01
The Platform Precision Autopilot is an instrument landing system interfaced autopilot system, developed to enable an aircraft to repeatedly fly nearly the same trajectory hours, days, or weeks later. The Platform Precision Autopilot uses a novel design to interface with a NASA Gulfstream III jet by imitating the output of an instrument landing system approach. This technique minimizes, as much as possible, modifications to the baseline Gulfstream III jet and retains the safety features of the aircraft autopilot. The Platform Precision Autopilot requirement is to fly within a 5-m (16.4-ft) radius tube for distances to 200 km (108 nmi) in the presence of light turbulence for at least 90 percent of the time. This capability allows precise repeat-pass interferometry for the Uninhabited Aerial Vehicle Synthetic Aperture Radar program, whose primary objective is to develop a miniaturized, polarimetric, L-band synthetic aperture radar. Precise navigation is achieved using an accurate differential global positioning system developed by the Jet Propulsion Laboratory. Flight-testing has demonstrated the ability of the Platform Precision Autopilot to control the aircraft within the specified tolerance greater than 90 percent of the time in the presence of aircraft system noise and nonlinearities, constant pilot throttle adjustments, and light turbulence.
Precision of working memory for visual motion sequences and transparent motion surfaces
Zokaei, Nahid; Gorgoraptis, Nikos; Bahrami, Bahador; Bays, Paul M; Husain, Masud
2012-01-01
Recent studies investigating working memory for location, colour and orientation support a dynamic resource model. We examined whether this might also apply to motion, using random dot kinematograms (RDKs) presented sequentially or simultaneously. Mean precision for motion direction declined as sequence length increased, with precision being lower for earlier RDKs. Two alternative models of working memory were compared specifically to distinguish between the contributions of different sources of error that corrupt memory (Zhang & Luck (2008) vs. Bays et al (2009)). The latter provided a significantly better fit for the data, revealing that decrease in memory precision for earlier items is explained by an increase in interference from other items in a sequence, rather than random guessing or a temporal decay of information. Misbinding feature attributes is an important source of error in working memory. Precision of memory for motion direction decreased when two RDKs were presented simultaneously as transparent surfaces, compared to sequential RDKs. However, precision was enhanced when one motion surface was prioritized, demonstrating that selective attention can improve recall precision. These results are consistent with a resource model that can be used as a general conceptual framework for understanding working memory across a range of visual features. PMID:22135378
Design and algorithm research of high precision airborne infrared touch screen
NASA Astrophysics Data System (ADS)
Zhang, Xiao-Bing; Wang, Shuang-Jie; Fu, Yan; Chen, Zhao-Quan
2016-10-01
There are shortcomings of low precision, touch shaking, and sharp decrease of touch precision when emitting and receiving tubes are failure in the infrared touch screen. A high precision positioning algorithm based on extended axis is proposed to solve these problems. First, the unimpeded state of the beam between emitting and receiving tubes is recorded as 0, while the impeded state is recorded as 1. Then, the method of oblique scan is used, in which the light of one emitting tube is used for five receiving tubes. The impeded information of all emitting and receiving tubes is collected as matrix. Finally, according to the method of arithmetic average, the position of the touch object is calculated. The extended axis positioning algorithm is characteristic of high precision in case of failure of individual infrared tube and affects slightly the precision. The experimental result shows that the 90% display area of the touch error is less than 0.25D, where D is the distance between adjacent emitting tubes. The conclusion is gained that the algorithm based on extended axis has advantages of high precision, little impact when individual infrared tube is failure, and using easily.
Yanq, Xuming; Ye, Yijun; Xia, Yong; Wei, Xuanzhong; Wang, Zheyu; Ni, Hongmei; Zhu, Ying; Xu, Lingyu
2015-02-01
To develop a more precise and accurate method, and identified a procedure to measure whether an acupoint had been correctly located. On the face, we used an acupoint location from different acupuncture experts and obtained the most precise and accurate values of acupoint location based on the consistency information fusion algorithm, through a virtual simulation of the facial orientation coordinate system. Because of inconsistencies in each acupuncture expert's original data, the system error the general weight calculation. First, we corrected each expert of acupoint location system error itself, to obtain a rational quantification for each expert of acupuncture and moxibustion acupoint location consistent support degree, to obtain pointwise variable precision fusion results, to put every expert's acupuncture acupoint location fusion error enhanced to pointwise variable precision. Then, we more effectively used the measured characteristics of different acupuncture expert's acupoint location, to improve the measurement information utilization efficiency and acupuncture acupoint location precision and accuracy. Based on using the consistency matrix pointwise fusion method on the acupuncture experts' acupoint location values, each expert's acupoint location information could be calculated, and the most precise and accurate values of each expert's acupoint location could be obtained.
A Lane-Level LBS System for Vehicle Network with High-Precision BDS/GPS Positioning
Guo, Chi; Guo, Wenfei; Cao, Guangyi; Dong, Hongbo
2015-01-01
In recent years, research on vehicle network location service has begun to focus on its intelligence and precision. The accuracy of space-time information has become a core factor for vehicle network systems in a mobile environment. However, difficulties persist in vehicle satellite positioning since deficiencies in the provision of high-quality space-time references greatly limit the development and application of vehicle networks. In this paper, we propose a high-precision-based vehicle network location service to solve this problem. The major components of this study include the following: (1) application of wide-area precise positioning technology to the vehicle network system. An adaptive correction message broadcast protocol is designed to satisfy the requirements for large-scale target precise positioning in the mobile Internet environment; (2) development of a concurrence service system with a flexible virtual expansion architecture to guarantee reliable data interaction between vehicles and the background; (3) verification of the positioning precision and service quality in the urban environment. Based on this high-precision positioning service platform, a lane-level location service is designed to solve a typical traffic safety problem. PMID:25755665
Precision medicine in cardiology.
Antman, Elliott M; Loscalzo, Joseph
2016-10-01
The cardiovascular research and clinical communities are ideally positioned to address the epidemic of noncommunicable causes of death, as well as advance our understanding of human health and disease, through the development and implementation of precision medicine. New tools will be needed for describing the cardiovascular health status of individuals and populations, including 'omic' data, exposome and social determinants of health, the microbiome, behaviours and motivations, patient-generated data, and the array of data in electronic medical records. Cardiovascular specialists can build on their experience and use precision medicine to facilitate discovery science and improve the efficiency of clinical research, with the goal of providing more precise information to improve the health of individuals and populations. Overcoming the barriers to implementing precision medicine will require addressing a range of technical and sociopolitical issues. Health care under precision medicine will become a more integrated, dynamic system, in which patients are no longer a passive entity on whom measurements are made, but instead are central stakeholders who contribute data and participate actively in shared decision-making. Many traditionally defined diseases have common mechanisms; therefore, elimination of a siloed approach to medicine will ultimately pave the path to the creation of a universal precision medicine environment.
Accuracy and Precision of Silicon Based Impression Media for Quantitative Areal Texture Analysis
Goodall, Robert H.; Darras, Laurent P.; Purnell, Mark A.
2015-01-01
Areal surface texture analysis is becoming widespread across a diverse range of applications, from engineering to ecology. In many studies silicon based impression media are used to replicate surfaces, and the fidelity of replication defines the quality of data collected. However, while different investigators have used different impression media, the fidelity of surface replication has not been subjected to quantitative analysis based on areal texture data. Here we present the results of an analysis of the accuracy and precision with which different silicon based impression media of varying composition and viscosity replicate rough and smooth surfaces. Both accuracy and precision vary greatly between different media. High viscosity media tested show very low accuracy and precision, and most other compounds showed either the same pattern, or low accuracy and high precision, or low precision and high accuracy. Of the media tested, mid viscosity President Jet Regular Body and low viscosity President Jet Light Body (Coltène Whaledent) are the only compounds to show high levels of accuracy and precision on both surface types. Our results show that data acquired from different impression media are not comparable, supporting calls for greater standardisation of methods in areal texture analysis. PMID:25991505
The economic case for precision medicine
Gavan, Sean P.; Thompson, Alexander J.; Payne, Katherine
2018-01-01
ABSTRACT Introduction: The advancement of precision medicine into routine clinical practice has been highlighted as an agenda for national and international health care policy. A principle barrier to this advancement is in meeting requirements of the payer or reimbursement agency for health care. This special report aims to explain the economic case for precision medicine, by accounting for the explicit objectives defined by decision-makers responsible for the allocation of limited health care resources. Areas covered: The framework of cost-effectiveness analysis, a method of economic evaluation, is used to describe how precision medicine can, in theory, exploit identifiable patient-level heterogeneity to improve population health outcomes and the relative cost-effectiveness of health care. Four case studies are used to illustrate potential challenges when demonstrating the economic case for a precision medicine in practice. Expert commentary: The economic case for a precision medicine should be considered at an early stage during its research and development phase. Clinical and economic evidence can be generated iteratively and should be in alignment with the objectives and requirements of decision-makers. Programmes of further research, to demonstrate the economic case of a precision medicine, can be prioritized by the extent that they reduce the uncertainty expressed by decision-makers. PMID:29682615
Precision Education Initiative: Moving toward Personalized Education
ERIC Educational Resources Information Center
Hart, Sara A.
2016-01-01
This article proposes the Precision Education Initiative, which is the tailoring of education to the specific characteristics of the individual student. Mirroring precision medicine, the author lays out both near-term and longer term goals that educational research, and importantly educational practice, should follow.
Current status and future trends of precision agricultural aviation technologies
USDA-ARS?s Scientific Manuscript database
Modern technologies and information tools can be used to maximize agricultural aviation productivity allowing for precision application of agrochemical products. This paper reviews and summarizes the state-of-the-art in precision agricultural aviation technology highlighting remote sensing, aerial s...
UAV low-altitude remote sensing for precision weed management
USDA-ARS?s Scientific Manuscript database
Precision weed management, an application of precision agriculture, accounts for within-field variability of weed infestation and herbicide damage. Unmanned aerial vehicles (UAVs) provide a unique platform for remote sensing of field crops. They are more efficient and flexible than manned agricultur...
Long, James M.; Nealis, Ashley
2017-01-01
The aim of the study was to determine whether location and sex affected the age precision estimates between two southern, reservoir populations of paddlefish [Polyodon spathula (Walbaum, 1792)]. From 589 paddlefish collected in Grand Lake and Keystone Lake, Oklahoma in 2011, ages from dentaries were estimated using three independent readers and precision was compared with coefficient of variation between locations and sexes. Ages were more precisely estimated from Grand Lake and from females.
Optimal actuator placement in adaptive precision trusses
NASA Technical Reports Server (NTRS)
Baycan, C. M.; Utku, S.; Das, S. K.; Wada, B. K.
1992-01-01
Actuator placement in adaptive truss structures is to cater to two needs: displacement control of precision points and preloading the elements to overcome joint slackness. Due to technological and financial considerations, the number of actuators available is much less than the degrees of freedom of precision points to be controlled and the degree of redundancy of the structure. An approach for optimal actuator location is outlined. Test cases to demonstrate the effectiveness of the scheme are applied to the Precision Segmented Reflector Truss.
Precision Medicine and the Changing Landscape of Research Ethics.
Hammer, Marilyn J
2016-03-01
President Barack Obama announced the launch of the National Institutes of Health Precision Medicine Initiative® (PMI) in January 2015. Precision medicine includes the concept of individualized or personalized medicine at a more exact level through advances in science and technology, such as genetics and genomics sequencing. Although many disease processes will be investigated through the precision medicine lens for greater understanding and improved treatment responses, oncology research and translation to practice is leading the initiative's debut, referred to as the near-term focus.
Study on manufacturing method of optical surface with high precision in angle and surface
NASA Astrophysics Data System (ADS)
Yu, Xin; Li, Xin; Yu, Ze; Zhao, Bin; Zhang, Xuebin; Sun, Lipeng; Tong, Yi
2016-10-01
This paper studied a manufacturing processing of optical surface with high precision in angel and surface. By theoretical analysis of the relationships between the angel precision and surface, the measurement conversion of the technical indicators, optical-cement method application, the optical-cement tooling design, the experiment has been finished successfully, the processing method has been verified, which can be also used in the manufacturing of the optical surface with similar high precision in angle and surface.
Khoo, Benjamin C C; Beck, Thomas J; Qiao, Qi-Hong; Parakh, Pallav; Semanick, Lisa; Prince, Richard L; Singer, Kevin P; Price, Roger I
2005-07-01
Hip structural analysis (HSA) is a technique for extracting strength-related structural dimensions of bone cross-sections from two-dimensional hip scan images acquired by dual energy X-ray absorptiometry (DXA) scanners. Heretofore the precision of the method has not been thoroughly tested in the clinical setting. Using paired scans from two large clinical trials involving a range of different DXA machines, this study reports the first precision analysis of HSA variables, in comparison with that of conventional bone mineral density (BMD) on the same scans. A key HSA variable, section modulus (Z), biomechanically indicative of bone strength during bending, had a short-term precision percentage coefficient of variation (CV%) in the femoral neck of 3.4-10.1%, depending on the manufacturer or model of the DXA equipment. Cross-sectional area (CSA), a determinant of bone strength during axial loading and closely aligned with conventional DXA bone mineral content, had a range of CV% from 2.8% to 7.9%. Poorer precision was associated with inadequate inclusion of the femoral shaft or femoral head in the DXA-scanned hip region. Precision of HSA-derived BMD varied between 2.4% and 6.4%. Precision of DXA manufacturer-derived BMD varied between 1.9% and 3.4%, arising from the larger analysis region of interest (ROI). The precision of HSA variables was not generally dependent on magnitude, subject height, weight, or conventional femoral neck densitometric variables. The generally poorer precision of key HSA variables in comparison with conventional DXA-derived BMD highlights the critical roles played by correct limb repositioning and choice of an adequate and appropriately positioned ROI.
NASA Astrophysics Data System (ADS)
Ford, Eric B.
2009-05-01
We present the results of a highly parallel Kepler equation solver using the Graphics Processing Unit (GPU) on a commercial nVidia GeForce 280GTX and the "Compute Unified Device Architecture" (CUDA) programming environment. We apply this to evaluate a goodness-of-fit statistic (e.g., χ2) for Doppler observations of stars potentially harboring multiple planetary companions (assuming negligible planet-planet interactions). Given the high-dimensionality of the model parameter space (at least five dimensions per planet), a global search is extremely computationally demanding. We expect that the underlying Kepler solver and model evaluator will be combined with a wide variety of more sophisticated algorithms to provide efficient global search, parameter estimation, model comparison, and adaptive experimental design for radial velocity and/or astrometric planet searches. We tested multiple implementations using single precision, double precision, pairs of single precision, and mixed precision arithmetic. We find that the vast majority of computations can be performed using single precision arithmetic, with selective use of compensated summation for increased precision. However, standard single precision is not adequate for calculating the mean anomaly from the time of observation and orbital period when evaluating the goodness-of-fit for real planetary systems and observational data sets. Using all double precision, our GPU code outperforms a similar code using a modern CPU by a factor of over 60. Using mixed precision, our GPU code provides a speed-up factor of over 600, when evaluating nsys > 1024 models planetary systems each containing npl = 4 planets and assuming nobs = 256 observations of each system. We conclude that modern GPUs also offer a powerful tool for repeatedly evaluating Kepler's equation and a goodness-of-fit statistic for orbital models when presented with a large parameter space.
Pretorius, Etheresia
2017-01-01
The latest statistics from the 2016 heart disease and stroke statistics update shows that cardiovascular disease is the leading global cause of death, currently accounting for more than 17.3 million deaths per year. Type II diabetes is also on the rise with out-of-control numbers. To address these pandemics, we need to treat patients using an individualized patient care approach, but simultaneously gather data to support the precision medicine initiative. Last year the NIH announced the precision medicine initiative to generate novel knowledge regarding diseases, with a near-term focus on cancers, followed by a longer-term aim, applicable to a whole range of health applications and diseases. The focus of this paper is to suggest a combined effort between the latest precision medicine initiative, researchers and clinicians; whereby novel techniques could immediately make a difference in patient care, but long-term add to knowledge for use in precision medicine. We discuss the intricate relationship between individualized patient care and precision medicine and the current thoughts regarding which data is actually suitable for the precision medicine data gathering. The uses of viscoelastic techniques in precision medicine are discussed and how these techniques might give novel perspectives on the success of treatment regimes of cardiovascular patients are explored. Thrombo-embolic stroke, rheumathoid arthritis and type II diabetes are used as examples of diseases where precision medicine and a patient-orientated approach can possibly be implemented. In conclusion it is suggested that if all role players work together by embracing a new way of thought in treating and managing cardiovascular disease and diabetes will we be able to adequately address these out-ofcontrol conditions. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
NASA Astrophysics Data System (ADS)
Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming
2018-03-01
In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.
Optimetrics for Precise Navigation
NASA Technical Reports Server (NTRS)
Yang, Guangning; Heckler, Gregory; Gramling, Cheryl
2017-01-01
Optimetrics for Precise Navigation will be implemented on existing optical communication links. The ranging and Doppler measurements are conducted over communication data frame and clock. The measurement accuracy is two orders of magnitude better than TDRSS. It also has other advantages of: The high optical carrier frequency enables: (1) Immunity from ionosphere and interplanetary Plasma noise floor, which is a performance limitation for RF tracking; and (2) High antenna gain reduces terminal size and volume, enables high precision tracking in Cubesat, and in deep space smallsat. High Optical Pointing Precision provides: (a) spacecraft orientation, (b) Minimal additional hardware to implement Precise Optimetrics over optical comm link; and (c) Continuous optical carrier phase measurement will enable the system presented here to accept future optical frequency standard with much higher clock accuracy.
Tunable laser techniques for improving the precision of observational astronomy
NASA Astrophysics Data System (ADS)
Cramer, Claire E.; Brown, Steven W.; Lykke, Keith R.; Woodward, John T.; Bailey, Stephen; Schlegel, David J.; Bolton, Adam S.; Brownstein, Joel; Doherty, Peter E.; Stubbs, Christopher W.; Vaz, Amali; Szentgyorgyi, Andrew
2012-09-01
Improving the precision of observational astronomy requires not only new telescopes and instrumentation, but also advances in observing protocols, calibrations and data analysis. The Laser Applications Group at the National Institute of Standards and Technology in Gaithersburg, Maryland has been applying advances in detector metrology and tunable laser calibrations to problems in astronomy since 2007. Using similar measurement techniques, we have addressed a number of seemingly disparate issues: precision flux calibration for broad-band imaging, precision wavelength calibration for high-resolution spectroscopy, and precision PSF mapping for fiber spectrographs of any resolution. In each case, we rely on robust, commercially-available laboratory technology that is readily adapted to use at an observatory. In this paper, we give an overview of these techniques.
Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion
NASA Technical Reports Server (NTRS)
Cable, Hugo; Durkin, Gabriel A.
2010-01-01
We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.
Parameter estimation with entangled photons produced by parametric down-conversion.
Cable, Hugo; Durkin, Gabriel A
2010-07-02
We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.
SPM interferometer with large range for mirco-vibration measurement
NASA Astrophysics Data System (ADS)
Fu, Mingyi; Tang, Chaowei; He, Guotian; Hu, Jun; Wang, Li
2007-12-01
The measuring range and precision are two inconsistent parameters of traditional optical interferometry. In this paper, the interferometer measuring vibration with high precision and large range is proposed and its measuring principle is analyzed in detail. The interferometer obtains phase information by processing interference signals with two real-time phase discriminator and the vibration displacement could be gotten by expanding this phase. The measuring range was enlarged from half wavelength to millimeter. Meanwhile, the measuring precision was independent of external disturbance and vibration displacement measurement with high precision was realized. The measuring range of vibration displacement for 6000.5nm and the repeatable measuring precision was 5.72nm from experiment. The feasibility of the measuring method was validated by experiments.
Hypothesis testing for band size detection of high-dimensional banded precision matrices.
An, Baiguo; Guo, Jianhua; Liu, Yufeng
2014-06-01
Many statistical analysis procedures require a good estimator for a high-dimensional covariance matrix or its inverse, the precision matrix. When the precision matrix is banded, the Cholesky-based method often yields a good estimator of the precision matrix. One important aspect of this method is determination of the band size of the precision matrix. In practice, crossvalidation is commonly used; however, we show that crossvalidation not only is computationally intensive but can be very unstable. In this paper, we propose a new hypothesis testing procedure to determine the band size in high dimensions. Our proposed test statistic is shown to be asymptotically normal under the null hypothesis, and its theoretical power is studied. Numerical examples demonstrate the effectiveness of our testing procedure.
Precision Medicine: The New Frontier in Idiopathic Pulmonary Fibrosis.
Brownell, Robert; Kaminski, Naftali; Woodruff, Prescott G; Bradford, Williamson Z; Richeldi, Luca; Martinez, Fernando J; Collard, Harold R
2016-06-01
Precision medicine is defined by the National Institute of Health's Precision Medicine Initiative Working Group as an approach to disease treatment that takes into account individual variability in genes, environment, and lifestyle. There has been increased interest in applying the concept of precision medicine to idiopathic pulmonary fibrosis, in particular to search for genetic and molecular biomarker-based profiles (so called endotypes) that identify mechanistically distinct disease subgroups. The relevance of precision medicine to idiopathic pulmonary fibrosis is yet to be established, but we believe that it holds great promise to provide targeted and highly effective therapies to patients. In this manuscript, we describe the field's nascent efforts in genetic/molecular endotype identification and how environmental and behavioral subgroups may also be relevant to disease management.
The Vernier Caliper and Significant Figures.
ERIC Educational Resources Information Center
Oberhofer, E. S.
1985-01-01
Misconceptions occur because the caliper is often read with the same significant figures as a meter stick; however, the precision of the vernier caliper is greater than the precision of a meter stick. Clarification of scale reading, precision of both tools, and significant figures are discussed. (JN)
21 CFR 872.3165 - Precision attachment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Precision attachment. 872.3165 Section 872.3165 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3165 Precision attachment. (a) Identification. A...
Precision Learning Assessment: An Alternative to Traditional Assessment Techniques.
ERIC Educational Resources Information Center
Caltagirone, Paul J.; Glover, Christopher E.
1985-01-01
A continuous and curriculum-based assessment method, Precision Learning Assessment (PLA), which integrates precision teaching and norm-referenced techniques, was applied to a math computation curriculum for 214 third graders. The resulting districtwide learning curves defining average annual progress through the computation curriculum provided…
Chapter 10: Precision Agriculture for Sustainability and Environmental Protection
USDA-ARS?s Scientific Manuscript database
Available supplies of water for irrigation and other uses are becoming more limited around the world, and this trend is accelerating. Emerging computerized precision irrigation technologies will enable growers to apply water and agrochemicals more precisely and site-specifically to match the status...
Sensor-based precision fertilization for field crops
USDA-ARS?s Scientific Manuscript database
From the development of the first viable variable-rate fertilizer systems in the upper Midwest USA, precision agriculture is now approaching three decades old. Early precision fertilization practice relied on laboratory analysis of soil samples collected on a spatial pattern to define the nutrient-s...
Area under precision-recall curves for weighted and unweighted data.
Keilwagen, Jens; Grosse, Ivo; Grau, Jan
2014-01-01
Precision-recall curves are highly informative about the performance of binary classifiers, and the area under these curves is a popular scalar performance measure for comparing different classifiers. However, for many applications class labels are not provided with absolute certainty, but with some degree of confidence, often reflected by weights or soft labels assigned to data points. Computing the area under the precision-recall curve requires interpolating between adjacent supporting points, but previous interpolation schemes are not directly applicable to weighted data. Hence, even in cases where weights were available, they had to be neglected for assessing classifiers using precision-recall curves. Here, we propose an interpolation for precision-recall curves that can also be used for weighted data, and we derive conditions for classification scores yielding the maximum and minimum area under the precision-recall curve. We investigate accordances and differences of the proposed interpolation and previous ones, and we demonstrate that taking into account existing weights of test data is important for the comparison of classifiers.
Representing the Earth's shape: the polemics surrounding Maupertuis's expedition to Lapland.
NASA Astrophysics Data System (ADS)
Terrall, M.
1992-06-01
Historical accounts of quantification in the physical sciences in the eighteenth century have often been described as a straightforward series of steps in a process of maturation, as instruments and standards advanced in precision. This paper calls into question the self-evidence nature of precision by investigating the production and uses of measurements. In the case of the dispute over the shape of the Earth, centered in Paris in the 1730s, the precision of measurements was a matter to be interpreted, attacked, defended, and represented. The whole messy business, undertaken by the participants to win consensus from their contemporaries, took place in the context of academic politics and the intellectual fashions of the salons and the court. All parties to the dispute claimed to be drawing on precision measurements; evaluating precision turned out to require the use of a range of intellectual, mathematical, instrumental, political, and textual resources. The alleged precision was then used to construct and defend rival scientific programs and practices.
Use of genome editing tools in human stem cell-based disease modeling and precision medicine.
Wei, Yu-da; Li, Shuang; Liu, Gai-gai; Zhang, Yong-xian; Ding, Qiu-rong
2015-10-01
Precision medicine emerges as a new approach that takes into account individual variability. The successful conduct of precision medicine requires the use of precise disease models. Human pluripotent stem cells (hPSCs), as well as adult stem cells, can be differentiated into a variety of human somatic cell types that can be used for research and drug screening. The development of genome editing technology over the past few years, especially the CRISPR/Cas system, has made it feasible to precisely and efficiently edit the genetic background. Therefore, disease modeling by using a combination of human stem cells and genome editing technology has offered a new platform to generate " personalized " disease models, which allow the study of the contribution of individual genetic variabilities to disease progression and the development of precise treatments. In this review, recent advances in the use of genome editing in human stem cells and the generation of stem cell models for rare diseases and cancers are discussed.
Mazzocco, Michèle M M; Feigenson, Lisa; Halberda, Justin
2011-01-01
The Approximate Number System (ANS) is a primitive mental system of nonverbal representations that supports an intuitive sense of number in human adults, children, infants, and other animal species. The numerical approximations produced by the ANS are characteristically imprecise and, in humans, this precision gradually improves from infancy to adulthood. Throughout development, wide ranging individual differences in ANS precision are evident within age groups. These individual differences have been linked to formal mathematics outcomes, based on concurrent, retrospective, or short-term longitudinal correlations observed during the school age years. However, it remains unknown whether this approximate number sense actually serves as a foundation for these school mathematics abilities. Here we show that ANS precision measured at preschool, prior to formal instruction in mathematics, selectively predicts performance on school mathematics at 6 years of age. In contrast, ANS precision does not predict non-numerical cognitive abilities. To our knowledge, these results provide the first evidence for early ANS precision, measured before the onset of formal education, predicting later mathematical abilities.
Precise Near IR Radial Velocity First Light Observations With iSHELL
NASA Astrophysics Data System (ADS)
Cale, Bryson L.; Plavchan, Peter; Gagné, Jonathan; Gao, Peter; Nishimoto, America; Tanner, Angelle; Walp, Bernie; Brinkworth, Carolyn; Johnson, John Asher; Vasisht, Gautam
2018-01-01
We present our current progress on obtaining precise radial velocities with the new iSHELL spectrograph at NASA's Infrared Telescope Facility. To obtain precise RV's, we use a methane isotopologue absorption gas cell in the calibration unit. Over the past year, we've collected 3-12 epochs of 17 bright G, K, and M dwarfs at a high SNR. By focusing on late type type stars, we obtain relatively higher SNR in the near infrared. We've successfully updated both our spectral and RV extraction pipelines, with a few exceptions. Inherent to the iSHELL data is a wavelength dependent fringing component, which must be incorporated into our model to obtain adequate RV precision. With iSHELL's predecessor, CSHELL, we obtained a precision of 3 m/s on the bright M giant SV Peg. With further progress on our fringing and telluric models, we hope to obtain a precision of <3 m/s with iSHELL, sufficient to detect terrestrial planets in the habitable zone of nearby M dwarfs.
A double sealing technique for increasing the precision of headspace-gas chromatographic analysis.
Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian
2018-01-19
This paper investigates a new double sealing technique for increasing the precision of the headspace gas chromatographic method. The air leakage problem caused by the high pressure in the headspace vial during the headspace sampling process has a great impact to the measurement precision in the conventional headspace analysis (i.e., single sealing technique). The results (using ethanol solution as the model sample) show that the present technique is effective to minimize such a problem. The double sealing technique has an excellent measurement precision (RSD < 0.15%) and accuracy (recovery = 99.1%-100.6%) for the ethanol quantification. The detection precision of the present method was 10-20 times higher than that in earlier HS-GC work that use conventional single sealing technique. The present double sealing technique may open up a new avenue, and also serve as a general strategy for improving the performance (i.e., accuracy and precision) of headspace analysis of various volatile compounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.
2015-01-01
Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134
Area under Precision-Recall Curves for Weighted and Unweighted Data
Grosse, Ivo
2014-01-01
Precision-recall curves are highly informative about the performance of binary classifiers, and the area under these curves is a popular scalar performance measure for comparing different classifiers. However, for many applications class labels are not provided with absolute certainty, but with some degree of confidence, often reflected by weights or soft labels assigned to data points. Computing the area under the precision-recall curve requires interpolating between adjacent supporting points, but previous interpolation schemes are not directly applicable to weighted data. Hence, even in cases where weights were available, they had to be neglected for assessing classifiers using precision-recall curves. Here, we propose an interpolation for precision-recall curves that can also be used for weighted data, and we derive conditions for classification scores yielding the maximum and minimum area under the precision-recall curve. We investigate accordances and differences of the proposed interpolation and previous ones, and we demonstrate that taking into account existing weights of test data is important for the comparison of classifiers. PMID:24651729
Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M
2015-05-06
Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Buchner, Lena; Güntert, Peter
2015-02-03
Nuclear magnetic resonance (NMR) structures are represented by bundles of conformers calculated from different randomized initial structures using identical experimental input data. The spread among these conformers indicates the precision of the atomic coordinates. However, there is as yet no reliable measure of structural accuracy, i.e., how close NMR conformers are to the "true" structure. Instead, the precision of structure bundles is widely (mis)interpreted as a measure of structural quality. Attempts to increase precision often overestimate accuracy by tight bundles of high precision but much lower accuracy. To overcome this problem, we introduce a protocol for NMR structure determination with the software package CYANA, which produces, like the traditional method, bundles of conformers in agreement with a common set of conformational restraints but with a realistic precision that is, throughout a variety of proteins and NMR data sets, a much better estimate of structural accuracy than the precision of conventional structure bundles. Copyright © 2015 Elsevier Ltd. All rights reserved.
Search Filter Precision Can Be Improved By NOTing Out Irrelevant Content
Wilczynski, Nancy L.; McKibbon, K. Ann; Haynes, R. Brian
2011-01-01
Background: Most methodologic search filters developed for use in large electronic databases such as MEDLINE have low precision. One method that has been proposed but not tested for improving precision is NOTing out irrelevant content. Objective: To determine if search filter precision can be improved by NOTing out the text words and index terms assigned to those articles that are retrieved but are off-target. Design: Analytic survey. Methods: NOTing out unique terms in off-target articles and testing search filter performance in the Clinical Hedges Database. Main Outcome Measures: Sensitivity, specificity, precision and number needed to read (NNR). Results: For all purpose categories (diagnosis, prognosis and etiology) except treatment and for all databases (MEDLINE, EMBASE, CINAHL and PsycINFO), constructing search filters that NOTed out irrelevant content resulted in substantive improvements in NNR (over four-fold for some purpose categories and databases). Conclusion: Search filter precision can be improved by NOTing out irrelevant content. PMID:22195215
Solving lattice QCD systems of equations using mixed precision solvers on GPUs
NASA Astrophysics Data System (ADS)
Clark, M. A.; Babich, R.; Barros, K.; Brower, R. C.; Rebbi, C.
2010-09-01
Modern graphics hardware is designed for highly parallel numerical tasks and promises significant cost and performance benefits for many scientific applications. One such application is lattice quantum chromodynamics (lattice QCD), where the main computational challenge is to efficiently solve the discretized Dirac equation in the presence of an SU(3) gauge field. Using NVIDIA's CUDA platform we have implemented a Wilson-Dirac sparse matrix-vector product that performs at up to 40, 135 and 212 Gflops for double, single and half precision respectively on NVIDIA's GeForce GTX 280 GPU. We have developed a new mixed precision approach for Krylov solvers using reliable updates which allows for full double precision accuracy while using only single or half precision arithmetic for the bulk of the computation. The resulting BiCGstab and CG solvers run in excess of 100 Gflops and, in terms of iterations until convergence, perform better than the usual defect-correction approach for mixed precision.
Mazzocco, Michèle M. M.; Feigenson, Lisa; Halberda, Justin
2011-01-01
The Approximate Number System (ANS) is a primitive mental system of nonverbal representations that supports an intuitive sense of number in human adults, children, infants, and other animal species. The numerical approximations produced by the ANS are characteristically imprecise and, in humans, this precision gradually improves from infancy to adulthood. Throughout development, wide ranging individual differences in ANS precision are evident within age groups. These individual differences have been linked to formal mathematics outcomes, based on concurrent, retrospective, or short-term longitudinal correlations observed during the school age years. However, it remains unknown whether this approximate number sense actually serves as a foundation for these school mathematics abilities. Here we show that ANS precision measured at preschool, prior to formal instruction in mathematics, selectively predicts performance on school mathematics at 6 years of age. In contrast, ANS precision does not predict non-numerical cognitive abilities. To our knowledge, these results provide the first evidence for early ANS precision, measured before the onset of formal education, predicting later mathematical abilities. PMID:21935362
High precision locating control system based on VCM for Talbot lithography
NASA Astrophysics Data System (ADS)
Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song
2016-10-01
Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.
Precision medicine of aneurysmal subarachnoid hemorrhage, vasospasm and delayed cerebral ischemia.
Burrell, Christian; Avalon, Nicole E; Siegel, Jason; Pizzi, Michael; Dutta, Tumpa; Charlesworth, M Cristine; Freeman, William D
2016-11-01
Precision medicine provides individualized treatment of diseases through leveraging patient-to-patient variation. Aneurysmal subarachnoid hemorrhage carries tremendous morbidity and mortality with cerebral vasospasm and delayed cerebral ischemia proving devastating and unpredictable. Lack of treatment measures for these conditions could be improved through precision medicine. Areas covered: Discussed are the pathophysiology of CV and DCI, treatment guidelines, and evidence for precision medicine used for prediction and prevention of poor outcomes following aSAH. A PubMed search was performed using keywords cerebral vasospasm or delayed cerebral ischemia and either biomarkers, precision medicine, metabolomics, proteomics, or genomics. Over 200 peer-reviewed articles were evaluated. The studies presented cover biomarkers identified as predictive markers or therapeutic targets following aSAH. Expert commentary: The biomarkers reviewed here correlate with CV, DCI, and neurologic outcomes after aSAH. Though practical use in clinical management of aSAH is not well established, using these biomarkers as predictive tools or therapeutic targets demonstrates the potential of precision medicine.
Precision Spectrophotometric Calibration System for Dark Energy Instruments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schubnell, Michael S.
2015-06-30
For this research we build a precision calibration system and carried out measurements to demonstrate the precision that can be achieved with a high precision spectrometric calibration system. It was shown that the system is capable of providing a complete spectrophotometric calibration at the sub-pixel level. The calibration system uses a fast, high precision monochromator that can quickly and efficiently scan over an instrument’s entire spectral range with a spectral line width of less than 0.01 nm corresponding to a fraction of a pixel on the CCD. The system was extensively evaluated in the laboratory. Our research showed that amore » complete spectrophotometric calibration standard for spectroscopic survey instruments such as DESI is possible. The monochromator precision and repeatability to a small fraction of the DESI spectrograph LSF was demonstrated with re-initialization on every scan and thermal drift compensation by locking to multiple external line sources. A projector system that mimics telescope aperture for point source at infinity was demonstrated.« less
Precision Medicine and Men's Health.
Mata, Douglas A; Katchi, Farhan M; Ramasamy, Ranjith
2017-07-01
Precision medicine can greatly benefit men's health by helping to prevent, diagnose, and treat prostate cancer, benign prostatic hyperplasia, infertility, hypogonadism, and erectile dysfunction. For example, precision medicine can facilitate the selection of men at high risk for prostate cancer for targeted prostate-specific antigen screening and chemoprevention administration, as well as assist in identifying men who are resistant to medical therapy for prostatic hyperplasia, who may instead require surgery. Precision medicine-trained clinicians can also let couples know whether their specific cause of infertility should be bypassed by sperm extraction and in vitro fertilization to prevent abnormalities in their offspring. Though precision medicine's role in the management of hypogonadism has yet to be defined, it could be used to identify biomarkers associated with individual patients' responses to treatment so that appropriate therapy can be prescribed. Last, precision medicine can improve erectile dysfunction treatment by identifying genetic polymorphisms that regulate response to medical therapies and by aiding in the selection of patients for further cardiovascular disease screening.
Study on high-precision measurement of long radius of curvature
NASA Astrophysics Data System (ADS)
Wu, Dongcheng; Peng, Shijun; Gao, Songtao
2016-09-01
It is hard to get high-precision measurement of the radius of curvature (ROC), because of many factors that affect the measurement accuracy. For the measurement of long radius of curvature, some factors take more important position than others'. So, at first this paper makes some research about which factor is related to the long measurement distance, and also analyse the uncertain of the measurement accuracy. At second this article also study the influence about the support status and the adjust error about the cat's eye and confocal position. At last, a 1055micrometer radius of curvature convex is measured in high-precision laboratory. Experimental results show that the proper steady support (three-point support) can guarantee the high-precision measurement of radius of curvature. Through calibrating the gain of cat's eye and confocal position, is useful to ensure the precise position in order to increase the measurement accuracy. After finish all the above process, the high-precision long ROC measurement is realized.
[Precision Nursing: Individual-Based Knowledge Translation].
Chiang, Li-Chi; Yeh, Mei-Ling; Su, Sui-Lung
2016-12-01
U.S. President Obama announced a new era of precision medicine in the Precision Medicine Initiative (PMI). This initiative aims to accelerate the progress of personalized medicine in light of individual requirements for prevention and treatment in order to improve the state of individual and public health. The recent and dramatic development of large-scale biologic databases (such as the human genome sequence), powerful methods for characterizing patients (such as genomics, microbiome, diverse biomarkers, and even pharmacogenomics), and computational tools for analyzing big data are maximizing the potential benefits of precision medicine. Nursing science should follow and keep pace with this trend in order to develop empirical knowledge and expertise in the area of personalized nursing care. Nursing scientists must encourage, examine, and put into practice innovative research on precision nursing in order to provide evidence-based guidance to clinical practice. The applications in personalized precision nursing care include: explanations of personalized information such as the results of genetic testing; patient advocacy and support; anticipation of results and treatment; ongoing chronic monitoring; and support for shared decision-making throughout the disease trajectory. Further, attention must focus on the family and the ethical implications of taking a personalized approach to care. Nurses will need to embrace the paradigm shift to precision nursing and work collaboratively across disciplines to provide the optimal personalized care to patients. If realized, the full potential of precision nursing will provide the best chance for good health for all.
Precision of measurement and body size in whole-body air-displacement plethysmography.
Wells, J C; Fuller, N J
2001-08-01
To investigate methodological and biological precision for air-displacement plethysmography (ADP) across a wide range of body size. Repeated measurements of body volume (BV) and body weight (WT), and derived estimates of density (BD) and indices of fat mass (FM) and fat-free mass (FFM). Sixteen men, aged 22--48 y; 12 women, aged 24--42 y; 13 boys, aged 5--14 y; 17 girls, aged 5--16 y. BV and WT were measured using the Bodpod ADP system from which estimates of BD, FM and FFM were derived. FM and FFM were further adjusted for height to give fat mass index (FMI) and fat-free mass index (FFMI). ADP is very precise for measuring both BV and BD (between 0.16 and 0.44% of the mean). After removing two outliers from the database, and converting BD to body composition, precision of FMI was <6% in adults and within 8% in children, while precision of FFMI was within 1.5% for both age groups. ADP shows good precision for BV and BD across a wide range of body size, subject to biological artefacts. If aberrant values can be identified and rejected, precision of body composition is also good. Aberrant values can be identified by using pairs of ADP procedures, allowing the rejection of data where successive BD values differed by >0.007 kg/l. Precision of FMI obtained using pairs of procedures improves to <4.5% in adults and <5.5% in children.
Efficient exploration of cosmology dependence in the EFT of LSS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cataneo, Matteo; Foreman, Simon; Senatore, Leonardo, E-mail: matteoc@dark-cosmology.dk, E-mail: sfore@stanford.edu, E-mail: senatore@stanford.edu
The most effective use of data from current and upcoming large scale structure (LSS) and CMB observations requires the ability to predict the clustering of LSS with very high precision. The Effective Field Theory of Large Scale Structure (EFTofLSS) provides an instrument for performing analytical computations of LSS observables with the required precision in the mildly nonlinear regime. In this paper, we develop efficient implementations of these computations that allow for an exploration of their dependence on cosmological parameters. They are based on two ideas. First, once an observable has been computed with high precision for a reference cosmology, formore » a new cosmology the same can be easily obtained with comparable precision just by adding the difference in that observable, evaluated with much less precision. Second, most cosmologies of interest are sufficiently close to the Planck best-fit cosmology that observables can be obtained from a Taylor expansion around the reference cosmology. These ideas are implemented for the matter power spectrum at two loops and are released as public codes. When applied to cosmologies that are within 3σ of the Planck best-fit model, the first method evaluates the power spectrum in a few minutes on a laptop, with results that have 1% or better precision, while with the Taylor expansion the same quantity is instantly generated with similar precision. The ideas and codes we present may easily be extended for other applications or higher-precision results.« less
Efficient exploration of cosmology dependence in the EFT of LSS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cataneo, Matteo; Foreman, Simon; Senatore, Leonardo
The most effective use of data from current and upcoming large scale structure (LSS) and CMB observations requires the ability to predict the clustering of LSS with very high precision. The Effective Field Theory of Large Scale Structure (EFTofLSS) provides an instrument for performing analytical computations of LSS observables with the required precision in the mildly nonlinear regime. In this paper, we develop efficient implementations of these computations that allow for an exploration of their dependence on cosmological parameters. They are based on two ideas. First, once an observable has been computed with high precision for a reference cosmology, formore » a new cosmology the same can be easily obtained with comparable precision just by adding the difference in that observable, evaluated with much less precision. Second, most cosmologies of interest are sufficiently close to the Planck best-fit cosmology that observables can be obtained from a Taylor expansion around the reference cosmology. These ideas are implemented for the matter power spectrum at two loops and are released as public codes. When applied to cosmologies that are within 3σ of the Planck best-fit model, the first method evaluates the power spectrum in a few minutes on a laptop, with results that have 1% or better precision, while with the Taylor expansion the same quantity is instantly generated with similar precision. Finally, the ideas and codes we present may easily be extended for other applications or higher-precision results.« less
Zheng, Y.
2013-01-01
Temporal sound cues are essential for sound recognition, pitch, rhythm, and timbre perception, yet how auditory neurons encode such cues is subject of ongoing debate. Rate coding theories propose that temporal sound features are represented by rate tuned modulation filters. However, overwhelming evidence also suggests that precise spike timing is an essential attribute of the neural code. Here we demonstrate that single neurons in the auditory midbrain employ a proportional code in which spike-timing precision and firing reliability covary with the sound envelope cues to provide an efficient representation of the stimulus. Spike-timing precision varied systematically with the timescale and shape of the sound envelope and yet was largely independent of the sound modulation frequency, a prominent cue for pitch. In contrast, spike-count reliability was strongly affected by the modulation frequency. Spike-timing precision extends from sub-millisecond for brief transient sounds up to tens of milliseconds for sounds with slow-varying envelope. Information theoretic analysis further confirms that spike-timing precision depends strongly on the sound envelope shape, while firing reliability was strongly affected by the sound modulation frequency. Both the information efficiency and total information were limited by the firing reliability and spike-timing precision in a manner that reflected the sound structure. This result supports a temporal coding strategy in the auditory midbrain where proportional changes in spike-timing precision and firing reliability can efficiently signal shape and periodicity temporal cues. PMID:23636724
Efficient exploration of cosmology dependence in the EFT of LSS
Cataneo, Matteo; Foreman, Simon; Senatore, Leonardo
2017-04-18
The most effective use of data from current and upcoming large scale structure (LSS) and CMB observations requires the ability to predict the clustering of LSS with very high precision. The Effective Field Theory of Large Scale Structure (EFTofLSS) provides an instrument for performing analytical computations of LSS observables with the required precision in the mildly nonlinear regime. In this paper, we develop efficient implementations of these computations that allow for an exploration of their dependence on cosmological parameters. They are based on two ideas. First, once an observable has been computed with high precision for a reference cosmology, formore » a new cosmology the same can be easily obtained with comparable precision just by adding the difference in that observable, evaluated with much less precision. Second, most cosmologies of interest are sufficiently close to the Planck best-fit cosmology that observables can be obtained from a Taylor expansion around the reference cosmology. These ideas are implemented for the matter power spectrum at two loops and are released as public codes. When applied to cosmologies that are within 3σ of the Planck best-fit model, the first method evaluates the power spectrum in a few minutes on a laptop, with results that have 1% or better precision, while with the Taylor expansion the same quantity is instantly generated with similar precision. Finally, the ideas and codes we present may easily be extended for other applications or higher-precision results.« less
Beckmann, Jacques S; Lew, Daniel
2016-12-19
This era of groundbreaking scientific developments in high-resolution, high-throughput technologies is allowing the cost-effective collection and analysis of huge, disparate datasets on individual health. Proper data mining and translation of the vast datasets into clinically actionable knowledge will require the application of clinical bioinformatics. These developments have triggered multiple national initiatives in precision medicine-a data-driven approach centering on the individual. However, clinical implementation of precision medicine poses numerous challenges. Foremost, precision medicine needs to be contrasted with the powerful and widely used practice of evidence-based medicine, which is informed by meta-analyses or group-centered studies from which mean recommendations are derived. This "one size fits all" approach can provide inadequate solutions for outliers. Such outliers, which are far from an oddity as all of us fall into this category for some traits, can be better managed using precision medicine. Here, we argue that it is necessary and possible to bridge between precision medicine and evidence-based medicine. This will require worldwide and responsible data sharing, as well as regularly updated training programs. We also discuss the challenges and opportunities for achieving clinical utility in precision medicine. We project that, through collection, analyses and sharing of standardized medically relevant data globally, evidence-based precision medicine will shift progressively from therapy to prevention, thus leading eventually to improved, clinician-to-patient communication, citizen-centered healthcare and sustained well-being.
Long-term impact of precision agriculture on a farmer’s field
USDA-ARS?s Scientific Manuscript database
Targeting management practices and inputs with precision agriculture has high potential to meet some of the grand challenges of sustainability in the coming century. Although potential is high, few studies have documented long-term effects of precision agriculture on crop production and environmenta...
Covariate Imbalance and Precision in Measuring Treatment Effects
ERIC Educational Resources Information Center
Liu, Xiaofeng Steven
2011-01-01
Covariate adjustment can increase the precision of estimates by removing unexplained variance from the error in randomized experiments, although chance covariate imbalance tends to counteract the improvement in precision. The author develops an easy measure to examine chance covariate imbalance in randomization by standardizing the average…
[Anatomy of the liver: what you need to know].
Lafortune, M; Denys, A; Sauvanet, A; Schmidt, S
2007-01-01
A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.
Tool simplifies machining of pipe ends for precision welding
NASA Technical Reports Server (NTRS)
Matus, S. T.
1969-01-01
Single tool prepares a pipe end for precision welding by simultaneously performing internal machining, end facing, and bevel cutting to specification standards. The machining operation requires only one milling adjustment, can be performed quickly, and produces the high quality pipe-end configurations required to ensure precision-welded joints.
MEASUREMENT AND PRECISION, EXPERIMENTAL VERSION.
ERIC Educational Resources Information Center
Harvard Univ., Cambridge, MA. Harvard Project Physics.
THIS DOCUMENT IS AN EXPERIMENTAL VERSION OF A PROGRAMED TEXT ON MEASUREMENT AND PRECISION. PART I CONTAINS 24 FRAMES DEALING WITH PRECISION AND SIGNIFICANT FIGURES ENCOUNTERED IN VARIOUS MATHEMATICAL COMPUTATIONS AND MEASUREMENTS. PART II BEGINS WITH A BRIEF SECTION ON EXPERIMENTAL DATA, COVERING SUCH POINTS AS (1) ESTABLISHING THE ZERO POINT, (2)…
ERIC Educational Resources Information Center
Couch, Richard W.
Precision teaching (PT) is an approach to the science of human behavior that focuses on precise monitoring of carefully defined behaviors in an attempt to construct an environmental analysis of that behavior and its controlling variables. A variety of subjects have been used with PT, ranging in academic objectives from beginning reading to college…
ERIC Educational Resources Information Center
Reid, Robert L.; And Others
This guide outlines the competency-based, two-year precision optics curriculum that the American Precision Optics Manufacturers Association has proposed to fill the void that it suggests will soon exist as many of the master opticians currently employed retire. The model, which closely resembles the old European apprenticeship model, calls for 300…
Precision Sheet Metal. Progress Record and Theory Outline.
ERIC Educational Resources Information Center
Connecticut State Dept. of Education, Hartford. Div. of Vocational-Technical Schools.
This combination progress record and course outline is designed for use by individuals teaching a course in precision sheet metal. Included among the topics addressed in the course are the following: employment opportunities in metalworking, measurement and layout, orthographic projection, precision sheet metal drafting, simple layout, hand tools,…
Predicting Document Retrieval System Performance: An Expected Precision Measure.
ERIC Educational Resources Information Center
Losee, Robert M., Jr.
1987-01-01
Describes an expected precision (EP) measure designed to predict document retrieval performance. Highlights include decision theoretic models; precision and recall as measures of system performance; EP graphs; relevance feedback; and computing the retrieval status value of a document for two models, the Binary Independent Model and the Two Poisson…
Precision of the anchor influences the amount of adjustment.
Janiszewski, Chris; Uy, Dan
2008-02-01
The anchoring-and-adjustment heuristic has been used to account for a wide variety of numerical judgments. Five studies show that adjustment away from a numerical anchor is smaller if the anchor is precise than if it is rounded. Evidence suggests that precise anchors, compared with rounded anchors, are represented on a subjective scale with a finer resolution. If adjustment consists of a series of iterative mental movements along a subjective scale, then an adjustment from a precise anchor should result in a smaller overall correction than an adjustment from a rounded anchor.
High-Precision Measurement of the Ne19 Half-Life and Implications for Right-Handed Weak Currents
NASA Astrophysics Data System (ADS)
Triambak, S.; Finlay, P.; Sumithrarachchi, C. S.; Hackman, G.; Ball, G. C.; Garrett, P. E.; Svensson, C. E.; Cross, D. S.; Garnsworthy, A. B.; Kshetri, R.; Orce, J. N.; Pearson, M. R.; Tardiff, E. R.; Al-Falou, H.; Austin, R. A. E.; Churchman, R.; Djongolov, M. K.; D'Entremont, R.; Kierans, C.; Milovanovic, L.; O'Hagan, S.; Reeve, S.; Sjue, S. K. L.; Williams, S. J.
2012-07-01
We report a precise determination of the Ne19 half-life to be T1/2=17.262±0.007s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.
Determination of the top quark mass circa 2013: methods, subtleties, perspectives
NASA Astrophysics Data System (ADS)
Juste, Aurelio; Mantry, Sonny; Mitov, Alexander; Penin, Alexander; Skands, Peter; Varnes, Erich; Vos, Marcel; Wimpenny, Stephen
2014-10-01
We present an up-to-date overview of the problem of top quark mass determination. We assess the need for precision in the top mass extraction in the LHC era together with the main theoretical and experimental issues arising in precision top mass determination. We collect and document existing results on top mass determination at hadron colliders and map the prospects for future precision top mass determination at e+e- colliders. We present a collection of estimates for the ultimate precision of various methods for top quark mass extraction at the LHC.
High-precision measurement of the 19Ne half-life and implications for right-handed weak currents.
Triambak, S; Finlay, P; Sumithrarachchi, C S; Hackman, G; Ball, G C; Garrett, P E; Svensson, C E; Cross, D S; Garnsworthy, A B; Kshetri, R; Orce, J N; Pearson, M R; Tardiff, E R; Al-Falou, H; Austin, R A E; Churchman, R; Djongolov, M K; D'Entremont, R; Kierans, C; Milovanovic, L; O'Hagan, S; Reeve, S; Sjue, S K L; Williams, S J
2012-07-27
We report a precise determination of the (19)Ne half-life to be T(1/2)=17.262±0.007 s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.
NASA Technical Reports Server (NTRS)
Segawa, J.; Ganeko, Y.; Sasaki, M.; Mori, T.; Ooe, M.; Nakagawa, I.; Ishii, H.; Hagiwara, Y.
1991-01-01
Our program includes five research items: (1) determination of a precision geoid and gravity anomaly field; (2) precise leveling and detection of tidal changes of the sea surface and study of the role of the tide in the global energy exchange; (3) oceanic effect on the Earth's rotation and polar motion; (4) geological and geophysical interpretation of the altimetry gravity field; and (5) evaluation of the effectiveness of local tracking of TOPEX/POSEIDON by use of a laser tracker.
Murat, Sema; Gurbuz, Ayhan; Isayev, Abulfaz; Dokmez, Bahadir; Cetin, Unsun
2012-01-01
The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator’s aesthetic advantages. This clinical report describes the prosthetic rehabilitation of two maxillary defects with an obturator retained using extracoronal resilient precision attachments. PMID:22509126
Truss Assembly and Welding by Intelligent Precision Jigging Robots
NASA Technical Reports Server (NTRS)
Komendera, Erik; Dorsey, John T.; Doggett, William R.; Correll, Nikolaus
2014-01-01
This paper describes an Intelligent Precision Jigging Robot (IPJR) prototype that enables the precise alignment and welding of titanium space telescope optical benches. The IPJR, equipped with micron accuracy sensors and actuators, worked in tandem with a lower precision remote controlled manipulator. The combined system assembled and welded a 2 m truss from stock titanium components. The calibration of the IPJR, and the difference between the predicted and the truss dimensions as-built, identified additional sources of error that should be addressed in the next generation of IPJRs in 2D and 3D.
High-Precision Half-Life Measurement for the Superallowed β+ Emitter Alm26
NASA Astrophysics Data System (ADS)
Finlay, P.; Ettenauer, S.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.
2011-01-01
A high-precision half-life measurement for the superallowed β+ emitter Alm26 was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1/2=6346.54±0.46stat±0.60systms, consistent with, but 2.5 times more precise than, the previous world average. The Alm26 half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed β decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for Alm26, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi β-decay studies used to test the conserved vector current hypothesis and determine the Vud element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.
Precise fiber length measurement using harmonic detection of phase-locked cavity modes
NASA Astrophysics Data System (ADS)
Terra, Osama
2018-06-01
In this paper, precise length measurements of optical fibers are performed by employing harmonic detection of the pulse-train frequency of a passively mode-locked fiber laser. This frequency is proportional to the length of the laser cavity in which the measured fiber is installed. Our proposed technique enables length measurement of long fibers from 1 to 40 km with precision from 0.4 to 8 mm and short fibers of few meters with precision as low as 26 μm. Such superior precision is achieved not only by the selection of higher harmonics of up to 1410, but also by the careful control of the wavelength at which the passive mode-locking occur, because of the broadband nature of the used gain medium.
Achieving sub-millimetre precision with a solid-state full-field heterodyning range imaging camera
NASA Astrophysics Data System (ADS)
Dorrington, A. A.; Cree, M. J.; Payne, A. D.; Conroy, R. M.; Carnegie, D. A.
2007-09-01
We have developed a full-field solid-state range imaging system capable of capturing range and intensity data simultaneously for every pixel in a scene with sub-millimetre range precision. The system is based on indirect time-of-flight measurements by heterodyning intensity-modulated illumination with a gain modulation intensified digital video camera. Sub-millimetre precision to beyond 5 m and 2 mm precision out to 12 m has been achieved. In this paper, we describe the new sub-millimetre class range imaging system in detail, and review the important aspects that have been instrumental in achieving high precision ranging. We also present the results of performance characterization experiments and a method of resolving the range ambiguity problem associated with homodyne and heterodyne ranging systems.
Precision Medicine: The New Frontier in Idiopathic Pulmonary Fibrosis
Brownell, Robert; Kaminski, Naftali; Woodruff, Prescott G.; Bradford, Williamson Z.; Richeldi, Luca; Martinez, Fernando J.
2016-01-01
Precision medicine is defined by the National Institute of Health’s Precision Medicine Initiative Working Group as an approach to disease treatment that takes into account individual variability in genes, environment, and lifestyle. There has been increased interest in applying the concept of precision medicine to idiopathic pulmonary fibrosis, in particular to search for genetic and molecular biomarker-based profiles (so called endotypes) that identify mechanistically distinct disease subgroups. The relevance of precision medicine to idiopathic pulmonary fibrosis is yet to be established, but we believe that it holds great promise to provide targeted and highly effective therapies to patients. In this manuscript, we describe the field’s nascent efforts in genetic/molecular endotype identification and how environmental and behavioral subgroups may also be relevant to disease management. PMID:26991475
Precision of working memory for visual motion sequences and transparent motion surfaces.
Zokaei, Nahid; Gorgoraptis, Nikos; Bahrami, Bahador; Bays, Paul M; Husain, Masud
2011-12-01
Recent studies investigating working memory for location, color, and orientation support a dynamic resource model. We examined whether this might also apply to motion, using random dot kinematograms (RDKs) presented sequentially or simultaneously. Mean precision for motion direction declined as sequence length increased, with precision being lower for earlier RDKs. Two alternative models of working memory were compared specifically to distinguish between the contributions of different sources of error that corrupt memory (W. Zhang & S. J. Luck, 2008 vs. P. M. Bays, R. F. G. Catalao, & M. Husain, 2009). The latter provided a significantly better fit for the data, revealing that decrease in memory precision for earlier items is explained by an increase in interference from other items in a sequence rather than random guessing or a temporal decay of information. Misbinding feature attributes is an important source of error in working memory. Precision of memory for motion direction decreased when two RDKs were presented simultaneously as transparent surfaces, compared to sequential RDKs. However, precision was enhanced when one motion surface was prioritized, demonstrating that selective attention can improve recall precision. These results are consistent with a resource model that can be used as a general conceptual framework for understanding working memory across a range of visual features.
Working memory recall precision is a more sensitive index than span.
Zokaei, Nahid; Burnett Heyes, Stephanie; Gorgoraptis, Nikos; Budhdeo, Sanjay; Husain, Masud
2015-09-01
Delayed adjustment tasks have recently been developed to examine working memory (WM) precision, that is, the resolution with which items maintained in memory are recalled. However, despite their emerging use in experimental studies of healthy people, evaluation of patient populations is sparse. We first investigated the validity of adjustment tasks, comparing precision with classical span measures of memory across the lifespan in 114 people. Second, we asked whether precision measures can potentially provide a more sensitive measure of WM than traditional span measures. Specifically, we tested this hypothesis examining WM in a group with early, untreated Parkinson's disease (PD) and its modulation by subsequent treatment on dopaminergic medication. Span measures correlated with precision across the lifespan: in children, young, and elderly participants. However, they failed to detect changes in WM in PD patients, either pre- or post-treatment initiation. By contrast, recall precision was sensitive enough to pick up such changes. PD patients pre-medication were significantly impaired compared to controls, but improved significantly after 3 months of being established on dopaminergic medication. These findings suggest that precision methods might provide a sensitive means to investigate WM and its modulation by interventions in clinical populations. © 2014 The Authors Journal of Neuropsychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Majhi, S.K., E-mail: tpskm@iacs.res.in; Mukhopadhyay, A., E-mail: aditi_mukhopadhyay@baylor.edu; Ward, B.F.L., E-mail: bfl_ward@baylor.edu
2014-11-15
We present a phenomenological study of the current status of the application of our approach of exact amplitude-based resummation in quantum field theory to precision QCD calculations, by realistic MC event generator methods, as needed for precision LHC physics. We discuss recent results as they relate to the interplay of the attendant IR-improved DGLAP-CS theory of one of us and the precision of exact NLO matrix-element matched parton shower MC’s in the Herwig6.5 environment as determined by comparison to recent LHC experimental observations on single heavy gauge boson production and decay. The level of agreement between the new theory andmore » the data continues to be a reason for optimism. In the spirit of completeness, we discuss as well other approaches to the same theoretical predictions that we make here from the standpoint of physical precision with an eye toward the (sub-)1% QCD⊗EW total theoretical precision regime for LHC physics. - Highlights: • Using LHC data, we show that IR-improved DGLAP-CS kernels with exact NLO Shower/ME matching improves MC precision. • We discuss other possible approaches in comparison with ours. • We propose experimental tests to discriminate between competing approaches.« less
Churnside, Allison B; Sullan, Ruby May A; Nguyen, Duc M; Case, Sara O; Bull, Matthew S; King, Gavin M; Perkins, Thomas T
2012-07-11
Force drift is a significant, yet unresolved, problem in atomic force microscopy (AFM). We show that the primary source of force drift for a popular class of cantilevers is their gold coating, even though they are coated on both sides to minimize drift. Drift of the zero-force position of the cantilever was reduced from 900 nm for gold-coated cantilevers to 70 nm (N = 10; rms) for uncoated cantilevers over the first 2 h after wetting the tip; a majority of these uncoated cantilevers (60%) showed significantly less drift (12 nm, rms). Removing the gold also led to ∼10-fold reduction in reflected light, yet short-term (0.1-10 s) force precision improved. Moreover, improved force precision did not require extended settling; most of the cantilevers tested (9 out of 15) achieved sub-pN force precision (0.54 ± 0.02 pN) over a broad bandwidth (0.01-10 Hz) just 30 min after loading. Finally, this precision was maintained while stretching DNA. Hence, removing gold enables both routine and timely access to sub-pN force precision in liquid over extended periods (100 s). We expect that many current and future applications of AFM can immediately benefit from these improvements in force stability and precision.
Precision oncology: origins, optimism, and potential.
Prasad, Vinay; Fojo, Tito; Brada, Michael
2016-02-01
Imatinib, the first and arguably the best targeted therapy, became the springboard for developing drugs aimed at molecular targets deemed crucial to tumours. As this development unfolded, a revolution in the speed and cost of genetic sequencing occurred. The result--an armamentarium of drugs and an array of molecular targets--set the stage for precision oncology, a hypothesis that cancer treatment could be markedly improved if therapies were guided by a tumour's genomic alterations. Drawing lessons from the biological basis of cancer and recent empirical investigations, we take a more measured view of precision oncology's promise. Ultimately, the promise is not our concern, but the threshold at which we declare success. We review reports of precision oncology alongside those of precision diagnostics and novel radiotherapy approaches. Although confirmatory evidence is scarce, these interventions have been widely endorsed. We conclude that the current path will probably not be successful or, at a minimum, will have to undergo substantive adjustments before it can be successful. For the sake of patients with cancer, we hope one form of precision oncology will deliver on its promise. However, until confirmatory studies are completed, precision oncology remains unproven, and as such, a hypothesis in need of rigorous testing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bragança, Sara; Arezes, Pedro; Carvalho, Miguel; Ashdown, Susan P; Castellucci, Ignacio; Leão, Celina
2018-01-01
Collecting anthropometric data for real-life applications demands a high degree of precision and reliability. It is important to test new equipment that will be used for data collectionOBJECTIVE:Compare two anthropometric data gathering techniques - manual methods and a Kinect-based 3D body scanner - to understand which of them gives more precise and reliable results. The data was collected using a measuring tape and a Kinect-based 3D body scanner. It was evaluated in terms of precision by considering the regular and relative Technical Error of Measurement and in terms of reliability by using the Intraclass Correlation Coefficient, Reliability Coefficient, Standard Error of Measurement and Coefficient of Variation. The results obtained showed that both methods presented better results for reliability than for precision. Both methods showed relatively good results for these two variables, however, manual methods had better results for some body measurements. Despite being considered sufficiently precise and reliable for certain applications (e.g. apparel industry), the 3D scanner tested showed, for almost every anthropometric measurement, a different result than the manual technique. Many companies design their products based on data obtained from 3D scanners, hence, understanding the precision and reliability of the equipment used is essential to obtain feasible results.
Expertise for upright faces improves the precision but not the capacity of visual working memory.
Lorenc, Elizabeth S; Pratte, Michael S; Angeloni, Christopher F; Tong, Frank
2014-10-01
Considerable research has focused on how basic visual features are maintained in working memory, but little is currently known about the precision or capacity of visual working memory for complex objects. How precisely can an object be remembered, and to what extent might familiarity or perceptual expertise contribute to working memory performance? To address these questions, we developed a set of computer-generated face stimuli that varied continuously along the dimensions of age and gender, and we probed participants' memories using a method-of-adjustment reporting procedure. This paradigm allowed us to separately estimate the precision and capacity of working memory for individual faces, on the basis of the assumptions of a discrete capacity model, and to assess the impact of face inversion on memory performance. We found that observers could maintain up to four to five items on average, with equally good memory capacity for upright and upside-down faces. In contrast, memory precision was significantly impaired by face inversion at every set size tested. Our results demonstrate that the precision of visual working memory for a complex stimulus is not strictly fixed but, instead, can be modified by learning and experience. We find that perceptual expertise for upright faces leads to significant improvements in visual precision, without modifying the capacity of working memory.
Classification of LIDAR Data for Generating a High-Precision Roadway Map
NASA Astrophysics Data System (ADS)
Jeong, J.; Lee, I.
2016-06-01
Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.
The Paradox of Abstraction: Precision Versus Concreteness.
Iliev, Rumen; Axelrod, Robert
2017-06-01
We introduce a novel measure of abstractness based on the amount of information of a concept computed from its position in a semantic taxonomy. We refer to this measure as precision. We propose two alternative ways to measure precision, one based on the path length from a concept to the root of the taxonomic tree, and another one based on the number of direct and indirect descendants. Since more information implies greater processing load, we hypothesize that nouns higher in precision will have a processing disadvantage in a lexical decision task. We contrast precision to concreteness, a common measure of abstractness based on the proportion of sensory-based information associated with a concept. Since concreteness facilitates cognitive processing, we predict that while both concreteness and precision are measures of abstractness, they will have opposite effects on performance. In two studies we found empirical support for our hypothesis. Precision and concreteness had opposite effects on latency and accuracy in a lexical decision task, and these opposite effects were observable while controlling for word length, word frequency, affective content and semantic diversity. Our results support the view that concepts organization includes amodal semantic structures which are independent of sensory information. They also suggest that we should distinguish between sensory-based and amount-of-information-based abstractness.
Challenges in mold manufacturing for high precision molded diffractive optical elements
NASA Astrophysics Data System (ADS)
Pongs, Guido; Bresseler, Bernd; Schweizer, Klaus; Bergs, Thomas
2016-09-01
Isothermal precision glass molding of imaging optics is the key technology for mass production of precise optical elements. Especially for numerous consumer applications (e.g. digital cameras, smart phones, …), high precision glass molding is applied for the manufacturing of aspherical lenses. The usage of diffractive optical elements (DOEs) can help to further reduce the number of lenses in the optical systems which will lead to a reduced weight of hand-held optical devices. But today the application of molded glass DOEs is limited due to the technological challenges in structuring the mold surfaces. Depending on the application submicrometer structures are required on the mold surface. Furthermore these structures have to be replicated very precisely to the glass lens surface. Especially the micro structuring of hard and brittle mold materials such as Tungsten Carbide is very difficult and not established. Thus a multitude of innovative approaches using diffractive optical elements cannot be realized. Aixtooling has investigated in different mold materials and different suitable machining technologies for the micro- and sub-micrometer structuring of mold surfaces. The focus of the work lays on ultra-precision grinding to generate the diffractive pattern on the mold surfaces. This paper presents the latest achievements in diffractive structuring of Tungsten Carbide mold surfaces by ultra-precision grinding.
Precision medicine needs pioneering clinical bioinformaticians.
Gómez-López, Gonzalo; Dopazo, Joaquín; Cigudosa, Juan C; Valencia, Alfonso; Al-Shahrour, Fátima
2017-10-25
Success in precision medicine depends on accessing high-quality genetic and molecular data from large, well-annotated patient cohorts that couple biological samples to comprehensive clinical data, which in conjunction can lead to effective therapies. From such a scenario emerges the need for a new professional profile, an expert bioinformatician with training in clinical areas who can make sense of multi-omics data to improve therapeutic interventions in patients, and the design of optimized basket trials. In this review, we first describe the main policies and international initiatives that focus on precision medicine. Secondly, we review the currently ongoing clinical trials in precision medicine, introducing the concept of 'precision bioinformatics', and we describe current pioneering bioinformatics efforts aimed at implementing tools and computational infrastructures for precision medicine in health institutions around the world. Thirdly, we discuss the challenges related to the clinical training of bioinformaticians, and the urgent need for computational specialists capable of assimilating medical terminologies and protocols to address real clinical questions. We also propose some skills required to carry out common tasks in clinical bioinformatics and some tips for emergent groups. Finally, we explore the future perspectives and the challenges faced by precision medicine bioinformatics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zender, Charles S.
2016-09-19
Geoscientific models and measurements generate false precision (scientifically meaningless data bits) that wastes storage space. False precision can mislead (by implying noise is signal) and be scientifically pointless, especially for measurements. By contrast, lossy compression can be both economical (save space) and heuristic (clarify data limitations) without compromising the scientific integrity of data. Data quantization can thus be appropriate regardless of whether space limitations are a concern. We introduce, implement, and characterize a new lossy compression scheme suitable for IEEE floating-point data. Our new Bit Grooming algorithm alternately shaves (to zero) and sets (to one) the least significant bits ofmore » consecutive values to preserve a desired precision. This is a symmetric, two-sided variant of an algorithm sometimes called Bit Shaving that quantizes values solely by zeroing bits. Our variation eliminates the artificial low bias produced by always zeroing bits, and makes Bit Grooming more suitable for arrays and multi-dimensional fields whose mean statistics are important. Bit Grooming relies on standard lossless compression to achieve the actual reduction in storage space, so we tested Bit Grooming by applying the DEFLATE compression algorithm to bit-groomed and full-precision climate data stored in netCDF3, netCDF4, HDF4, and HDF5 formats. Bit Grooming reduces the storage space required by initially uncompressed and compressed climate data by 25–80 and 5–65 %, respectively, for single-precision values (the most common case for climate data) quantized to retain 1–5 decimal digits of precision. The potential reduction is greater for double-precision datasets. When used aggressively (i.e., preserving only 1–2 digits), Bit Grooming produces storage reductions comparable to other quantization techniques such as Linear Packing. Unlike Linear Packing, whose guaranteed precision rapidly degrades within the relatively narrow dynamic range of values that it can compress, Bit Grooming guarantees the specified precision throughout the full floating-point range. Data quantization by Bit Grooming is irreversible (i.e., lossy) yet transparent, meaning that no extra processing is required by data users/readers. Hence Bit Grooming can easily reduce data storage volume without sacrificing scientific precision or imposing extra burdens on users.« less
Cubison, M. J.; Jimenez, J. L.
2015-06-05
Least-squares fitting of overlapping peaks is often needed to separately quantify ions in high-resolution mass spectrometer data. A statistical simulation approach is used to assess the statistical precision of the retrieved peak intensities. The sensitivity of the fitted peak intensities to statistical noise due to ion counting is probed for synthetic data systems consisting of two overlapping ion peaks whose positions are pre-defined and fixed in the fitting procedure. The fitted intensities are sensitive to imperfections in the m/Q calibration. These propagate as a limiting precision in the fitted intensities that may greatly exceed the precision arising from counting statistics.more » The precision on the fitted peak intensity falls into one of three regimes. In the "counting-limited regime" (regime I), above a peak separation χ ~ 2 to 3 half-widths at half-maximum (HWHM), the intensity precision is similar to that due to counting error for an isolated ion. For smaller χ and higher ion counts (~ 1000 and higher), the intensity precision rapidly degrades as the peak separation is reduced ("calibration-limited regime", regime II). Alternatively for χ < 1.6 but lower ion counts (e.g. 10–100) the intensity precision is dominated by the additional ion count noise from the overlapping ion and is not affected by the imprecision in the m/Q calibration ("overlapping-limited regime", regime III). The transition between the counting and m/Q calibration-limited regimes is shown to be weakly dependent on resolving power and data spacing and can thus be approximated by a simple parameterisation based only on peak intensity ratios and separation. A simple equation can be used to find potentially problematic ion pairs when evaluating results from fitted spectra containing many ions. Longer integration times can improve the precision in regimes I and III, but a given ion pair can only be moved out of regime II through increased spectrometer resolving power. As a result, studies presenting data obtained from least-squares fitting procedures applied to mass spectral peaks should explicitly consider these limits on statistical precision.« less
Sanders, Geoff; Sinclair, Kamila
2011-12-01
We report two Internet studies that investigated sex differences in the accuracy and precision of judging time to arrival. We used accuracy to mean the ability to match the actual time to arrival and precision to mean the consistency with which each participant made their judgments. Our task was presented as a computer game in which a toy UFO moved obliquely towards the participant through a virtual three-dimensional space on route to a docking station. The UFO disappeared before docking and participants pressed their space bar at the precise moment they thought the UFO would have docked. Study 1 showed it was possible to conduct quantitative studies of spatiotemporal judgments in virtual reality via the Internet and confirmed reports that men are more accurate because women underestimate, but found no difference in precision measured as intra-participant variation. Study 2 repeated Study 1 with five additional presentations of one condition to provide a better measure of precision. Again, men were more accurate than women but there were no sex differences in precision. However, within the coincidence-anticipation timing (CAT) literature, of those studies that report sex differences, a majority found that males are both more accurate and more precise than females. Noting that many CAT studies report no sex differences, we discuss appropriate interpretations of such null findings. While acknowledging that CAT performance may be influenced by experience we suggest that the sex difference may have originated among our ancestors with the evolutionary selection of men for hunting and women for gathering.
El-Amrawy, Fatema
2015-01-01
Objectives The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Methods Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. Results The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. Conclusions The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure. PMID:26618039
El-Amrawy, Fatema; Nounou, Mohamed Ismail
2015-10-01
The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure.
Conducting Precision Medicine Research with African Americans.
Halbert, Chanita Hughes; McDonald, Jasmine; Vadaparampil, Susan; Rice, LaShanta; Jefferson, Melanie
2016-01-01
Precision medicine is an approach to detecting, treating, and managing disease that is based on individual variation in genetic, environmental, and lifestyle factors. Precision medicine is expected to reduce health disparities, but this will be possible only if studies have adequate representation of racial minorities. It is critical to anticipate the rates at which individuals from diverse populations are likely to participate in precision medicine studies as research initiatives are being developed. We evaluated the likelihood of participating in a clinical study for precision medicine. Observational study conducted between October 2010 and February 2011 in a national sample of African Americans. Intentions to participate in a government sponsored study that involves providing a biospecimen and generates data that could be shared with other researchers to conduct future studies. One third of respondents would participate in a clinical study for precision medicine. Only gender had a significant independent association with participation intentions. Men had a 1.86 (95% CI = 1.11, 3.12, p = 0.02) increased likelihood of participating in a precision medicine study compared to women in the model that included overall barriers and facilitators. In the model with specific participation barriers, distrust was associated with a reduced likelihood of participating in the research described in the vignette (OR = 0.57, 95% CI = 0.34, 0.96, p = 0.04). African Americans may have low enrollment in PMI research. As PMI research is implemented, extensive efforts will be needed to ensure adequate representation. Additional research is needed to identify optimal ways of ethically describing precision medicine studies to ensure sufficient recruitment of racial minorities.
Pratte, Michael S.; Park, Young Eun; Rademaker, Rosanne L.; Tong, Frank
2016-01-01
If we view a visual scene that contains many objects, then momentarily close our eyes, some details persist while others seem to fade. Discrete models of visual working memory (VWM) assume that only a few items can be actively maintained in memory, beyond which pure guessing will emerge. Alternatively, continuous resource models assume that all items in a visual scene can be stored with some precision. Distinguishing between these competing models is challenging, however, as resource models that allow for stochastically variable precision (across items and trials) can produce error distributions that resemble random guessing behavior. Here, we evaluated the hypothesis that a major source of variability in VWM performance arises from systematic variation in precision across the stimuli themselves; such stimulus-specific variability can be incorporated into both discrete-capacity and variable-precision resource models. Participants viewed multiple oriented gratings, and then reported the orientation of a cued grating from memory. When modeling the overall distribution of VWM errors, we found that the variable-precision resource model outperformed the discrete model. However, VWM errors revealed a pronounced “oblique effect”, with larger errors for oblique than cardinal orientations. After this source of variability was incorporated into both models, we found that the discrete model provided a better account of VWM errors. Our results demonstrate that variable precision across the stimulus space can lead to an unwarranted advantage for resource models that assume stochastically variable precision. When these deterministic sources are adequately modeled, human working memory performance reveals evidence of a discrete capacity limit. PMID:28004957
Pratte, Michael S; Park, Young Eun; Rademaker, Rosanne L; Tong, Frank
2017-01-01
If we view a visual scene that contains many objects, then momentarily close our eyes, some details persist while others seem to fade. Discrete models of visual working memory (VWM) assume that only a few items can be actively maintained in memory, beyond which pure guessing will emerge. Alternatively, continuous resource models assume that all items in a visual scene can be stored with some precision. Distinguishing between these competing models is challenging, however, as resource models that allow for stochastically variable precision (across items and trials) can produce error distributions that resemble random guessing behavior. Here, we evaluated the hypothesis that a major source of variability in VWM performance arises from systematic variation in precision across the stimuli themselves; such stimulus-specific variability can be incorporated into both discrete-capacity and variable-precision resource models. Participants viewed multiple oriented gratings, and then reported the orientation of a cued grating from memory. When modeling the overall distribution of VWM errors, we found that the variable-precision resource model outperformed the discrete model. However, VWM errors revealed a pronounced "oblique effect," with larger errors for oblique than cardinal orientations. After this source of variability was incorporated into both models, we found that the discrete model provided a better account of VWM errors. Our results demonstrate that variable precision across the stimulus space can lead to an unwarranted advantage for resource models that assume stochastically variable precision. When these deterministic sources are adequately modeled, human working memory performance reveals evidence of a discrete capacity limit. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Distribution and mitigation of higher-order ionospheric effects on precise GNSS processing
NASA Astrophysics Data System (ADS)
Hernández-Pajares, Manuel; Aragón-Ángel, Àngela; Defraigne, Pascale; Bergeot, Nicolas; Prieto-Cerdeira, Roberto; García-Rigo, Alberto
2014-04-01
Higher-order ionospheric effects (I2+) are one of the main limiting factors in very precise Global Navigation Satellite Systems (GNSS) processing, for applications where millimeter accuracy is demanded. This paper summarizes a comprehensive study of the I2+ effects in range and in GNSS precise products such as receiver position and clock, tropospheric delay, geocenter offset, and GNSS satellite position and clock. All the relevant higher-order contributions are considered: second and third orders, geometric bending, and slant total electron content (dSTEC) bending (i.e., the difference between the STEC for straight and bent paths). Using a realistic simulation with representative solar maximum conditions on GPS signals, both the effects and mitigation errors are analyzed. The usage of the combination of multifrequency L band observations has to be rejected due to its increased noise level. The results of the study show that the main two effects in range are the second-order ionospheric and dSTEC terms, with peak values up to 2 cm. Their combined impacts on the precise GNSS satellite products affects the satellite Z coordinates (up to +1 cm) and satellite clocks (more than ±20 ps). Other precise products are affected at the millimeter level. After correction the impact on all the precise GNSS products is reduced below 5 mm. We finally show that the I2+ impact on a Precise Point Positioning (PPP) user is lower than the current uncertainties of the PPP solutions, after applying consistently the precise products (satellite orbits and clocks) obtained under I2+ correction.
Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review.
Yang, Lu
2009-01-01
For many decades the accurate and precise determination of isotope ratios has remained a very strong interest to many researchers due to its important applications in earth, environmental, biological, archeological, and medical sciences. Traditionally, thermal ionization mass spectrometry (TIMS) has been the technique of choice for achieving the highest accuracy and precision. However, recent developments in multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) have brought a new dimension to this field. In addition to its simple and robust sample introduction, high sample throughput, and high mass resolution, the flat-topped peaks generated by this technique provide for accurate and precise determination of isotope ratios with precision reaching 0.001%, comparable to that achieved with TIMS. These features, in combination with the ability of the ICP source to ionize nearly all elements in the periodic table, have resulted in an increased use of MC-ICP-MS for such measurements in various sample matrices. To determine accurate and precise isotope ratios with MC-ICP-MS, utmost care must be exercised during sample preparation, optimization of the instrument, and mass bias corrections. Unfortunately, there are inconsistencies and errors evident in many MC-ICP-MS publications, including errors in mass bias correction models. This review examines "state-of-the-art" methodologies presented in the literature for achievement of precise and accurate determinations of isotope ratios by MC-ICP-MS. Some general rules for such accurate and precise measurements are suggested, and calculations of combined uncertainty of the data using a few common mass bias correction models are outlined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-06-01
Following a planning period during which the Lawrence Livermore Laboratory and the Department of Defense managing sponsor, the USAF Materials Laboratory, agreed on work statements, the Department of Defense Tri-Service Precision Machine-Tool Program began in February 1978. Milestones scheduled for the first quarter have been met. Tasks and manpower requirements for two basic projects, precision-machining commercialization (PMC) and a machine-tool task force (MTTF), were defined. Progress by PMC includes: (1) documentation of existing precision machine-tool technology by initiation and compilation of a bibliography containing several hundred entries: (2) identification of the problems and needs of precision turning-machine builders and ofmore » precision turning-machine users interested in developing high-precision machining capability; and (3) organization of the schedule and content of the first seminar, to be held in October 1978, which will bring together representatives from the machine-tool and optics communities to address the problems and begin the process of high-precision machining commercialization. Progress by MTTF includes: (1) planning for the organization of a team effort of approximately 60 to 80 international experts to contribute in various ways to project objectives, namely, to summarize state-of-the-art cutting-machine-tool technology and to identify areas where future R and D should prove technically and economically profitable; (2) preparation of a comprehensive plan to achieve those objectives; and (3) preliminary arrangements for a plenary session, also in October, when the task force will meet to formalize the details for implementing the plan.« less
NASA Astrophysics Data System (ADS)
Chauhan, H.; Krishna Mohan, B.
2014-11-01
The present study was undertaken with the objective to check effectiveness of spectral similarity measures to develop precise crop spectra from the collected hyperspectral field spectra. In Multispectral and Hyperspectral remote sensing, classification of pixels is obtained by statistical comparison (by means of spectral similarity) of known field or library spectra to unknown image spectra. Though these algorithms are readily used, little emphasis has been placed on use of various spectral similarity measures to select precise crop spectra from the set of field spectra. Conventionally crop spectra are developed after rejecting outliers based only on broad-spectrum analysis. Here a successful attempt has been made to develop precise crop spectra based on spectral similarity. As unevaluated data usage leads to uncertainty in the image classification, it is very crucial to evaluate the data. Hence, notwithstanding the conventional method, the data precision has been performed effectively to serve the purpose of the present research work. The effectiveness of developed precise field spectra was evaluated by spectral discrimination measures and found higher discrimination values compared to spectra developed conventionally. Overall classification accuracy for the image classified by field spectra selected conventionally is 51.89% and 75.47% for the image classified by field spectra selected precisely based on spectral similarity. KHAT values are 0.37, 0.62 and Z values are 2.77, 9.59 for image classified using conventional and precise field spectra respectively. Reasonable higher classification accuracy, KHAT and Z values shows the possibility of a new approach for field spectra selection based on spectral similarity measure.
USDA-ARS?s Scientific Manuscript database
Mineral concentration of plant biomass can affect its use in thermal conversion to energy. The objective of this study was to compare the precision and accuracy of university and private laboratories that conduct mineral analyses of plant biomass on a fee basis. Accuracy and precision of the laborat...
Science 101: How Do Atomic Clocks Work?
ERIC Educational Resources Information Center
Science and Children, 2008
2008-01-01
You might be wondering why in the world we need such precise measures of time. Well, many systems we use everyday, such as Global Positioning Systems, require precise synchronization of time. This comes into play in telecommunications and wireless communications, also. For purely scientific reasons, we can use precise measurement of time to…
Precise FIA plot registration using field and dense LIDAR data
Demetrios Gatziolis
2009-01-01
Precise registration of forest inventory and analysis (FIA) plots is a prerequisite for an effective fusion of field data with ancillary spatial information, which is an approach commonly employed in the mapping of various forest parameters. Although the adoption of Global Positioning System technology has improved the precision of plot coordinates obtained during...
Long-term impact of a precision agriculture system on grain crop production
USDA-ARS?s Scientific Manuscript database
Research is lacking on the long-term impacts of field-scale precision agriculture practices on grain production. Following more than a decade (1993-2003) of yield and soil mapping and water quality assessment, a multi-faceted, ‘precision agriculture system’ (PAS) was implemented from 2004 to 2014 on...
The Precision Efficacy Analysis for Regression Sample Size Method.
ERIC Educational Resources Information Center
Brooks, Gordon P.; Barcikowski, Robert S.
The general purpose of this study was to examine the efficiency of the Precision Efficacy Analysis for Regression (PEAR) method for choosing appropriate sample sizes in regression studies used for precision. The PEAR method, which is based on the algebraic manipulation of an accepted cross-validity formula, essentially uses an effect size to…
Power and Precision in Confirmatory Factor Analytic Tests of Measurement Invariance
ERIC Educational Resources Information Center
Meade, Adam W.; Bauer, Daniel J.
2007-01-01
This study investigates the effects of sample size, factor overdetermination, and communality on the precision of factor loading estimates and the power of the likelihood ratio test of factorial invariance in multigroup confirmatory factor analysis. Although sample sizes are typically thought to be the primary determinant of precision and power,…
Refining FIA plot locations using LiDAR point clouds
Charlie Schrader-Patton; Greg C. Liknes; Demetrios Gatziolis; Brian M. Wing; Mark D. Nelson; Patrick D. Miles; Josh Bixby; Daniel G. Wendt; Dennis Kepler; Abbey Schaaf
2015-01-01
Forest Inventory and Analysis (FIA) plot location coordinate precision is often insufficient for use with high resolution remotely sensed data, thereby limiting the use of these plots for geospatial applications and reducing the validity of models that assume the locations are precise. A practical and efficient method is needed to improve coordinate precision. To...
Reliability and precision of pellet-group counts for estimating landscape-level deer density
David S. deCalesta
2013-01-01
This study provides hitherto unavailable methodology for reliably and precisely estimating deer density within forested landscapes, enabling quantitative rather than qualitative deer management. Reliability and precision of the deer pellet-group technique were evaluated in 1 small and 2 large forested landscapes. Density estimates, adjusted to reflect deer harvest and...
Peer Assessment with Online Tools to Improve Student Modeling
ERIC Educational Resources Information Center
Atkins, Leslie J.
2012-01-01
Introductory physics courses often require students to develop precise models of phenomena and represent these with diagrams, including free-body diagrams, light-ray diagrams, and maps of field lines. Instructors expect that students will adopt a certain rigor and precision when constructing these diagrams, but we want that rigor and precision to…
Hsü, K J; Hsü, A J
1990-01-01
Music critics have compared Bach's music to the precision of mathematics. What "mathematics" and what "precision" are the questions for a curious scientist. The purpose of this short note is to suggest that the mathematics is, at least in part, Mandelbrot's fractal geometry and the precision is the deviation from a log-log linear plot. PMID:11607061
Measurement precision and noise analysis of CCD cameras
NASA Astrophysics Data System (ADS)
Wu, ZhenSen; Li, Zhiyang; Zhang, Ping
1993-09-01
CHINA The lirait precision of CCD camera with 1O. bit analogue to digital conversion is estimated in this paper . The noise effect on ineasurenent precision and the noise characteristics are analyzed in details. The noise process means are also discussed and the diagram of noise properties is given in this paper.
Time Delay Embedding Increases Estimation Precision of Models of Intraindividual Variability
ERIC Educational Resources Information Center
von Oertzen, Timo; Boker, Steven M.
2010-01-01
This paper investigates the precision of parameters estimated from local samples of time dependent functions. We find that "time delay embedding," i.e., structuring data prior to analysis by constructing a data matrix of overlapping samples, increases the precision of parameter estimates and in turn statistical power compared to standard…
Research on the tool holder mode in high speed machining
NASA Astrophysics Data System (ADS)
Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao
2018-03-01
High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.
Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L
2018-01-01
The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
A farm-level precision land management framework based on integer programming
Li, Qi; Hu, Guiping; Jubery, Talukder Zaki; Ganapathysubramanian, Baskar
2017-01-01
Farmland management involves several planning and decision making tasks including seed selection and irrigation management. A farm-level precision farmland management model based on mixed integer linear programming is proposed in this study. Optimal decisions are designed for pre-season planning of crops and irrigation water allocation. The model captures the effect of size and shape of decision scale as well as special irrigation patterns. The authors illustrate the model with a case study on a farm in the state of California in the U.S. and show the model can capture the impact of precision farm management on profitability. The results show that threefold increase of annual net profit for farmers could be achieved by carefully choosing irrigation and seed selection. Although farmers could increase profits by applying precision management to seed or irrigation alone, profit increase is more significant if farmers apply precision management on seed and irrigation simultaneously. The proposed model can also serve as a risk analysis tool for farmers facing seasonal irrigation water limits as well as a quantitative tool to explore the impact of precision agriculture. PMID:28346499
Apparatus for precision micromachining with lasers
Chang, J.J.; Dragon, E.P.; Warner, B.E.
1998-04-28
A new material processing apparatus using a short-pulsed, high-repetition-rate visible laser for precision micromachining utilizes a near diffraction limited laser, a high-speed precision two-axis tilt-mirror for steering the laser beam, an optical system for either focusing or imaging the laser beam on the part, and a part holder that may consist of a cover plate and a back plate. The system is generally useful for precision drilling, cutting, milling and polishing of metals and ceramics, and has broad application in manufacturing precision components. Precision machining has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratios up to 1:40 have been consistently drilled with good surface finish on a variety of metals. Micromilling and microdrilling on ceramics using a 250 W copper vapor laser have also been demonstrated with good results. Materialographic sections of machined parts show little (submicron scale) recast layer and heat affected zone. 1 fig.
Precision forging technology for aluminum alloy
NASA Astrophysics Data System (ADS)
Deng, Lei; Wang, Xinyun; Jin, Junsong; Xia, Juchen
2018-03-01
Aluminum alloy is a preferred metal material for lightweight part manufacturing in aerospace, automobile, and weapon industries due to its good physical properties, such as low density, high specific strength, and good corrosion resistance. However, during forging processes, underfilling, folding, broken streamline, crack, coarse grain, and other macro- or microdefects are easily generated because of the deformation characteristics of aluminum alloys, including narrow forgeable temperature region, fast heat dissipation to dies, strong adhesion, high strain rate sensitivity, and large flow resistance. Thus, it is seriously restricted for the forged part to obtain precision shape and enhanced property. In this paper, progresses in precision forging technologies of aluminum alloy parts were reviewed. Several advanced precision forging technologies have been developed, including closed die forging, isothermal die forging, local loading forging, metal flow forging with relief cavity, auxiliary force or vibration loading, casting-forging hybrid forming, and stamping-forging hybrid forming. High-precision aluminum alloy parts can be realized by controlling the forging processes and parameters or combining precision forging technologies with other forming technologies. The development of these technologies is beneficial to promote the application of aluminum alloys in manufacturing of lightweight parts.
High Precision Prediction of Functional Sites in Protein Structures
Buturovic, Ljubomir; Wong, Mike; Tang, Grace W.; Altman, Russ B.; Petkovic, Dragutin
2014-01-01
We address the problem of assigning biological function to solved protein structures. Computational tools play a critical role in identifying potential active sites and informing screening decisions for further lab analysis. A critical parameter in the practical application of computational methods is the precision, or positive predictive value. Precision measures the level of confidence the user should have in a particular computed functional assignment. Low precision annotations lead to futile laboratory investigations and waste scarce research resources. In this paper we describe an advanced version of the protein function annotation system FEATURE, which achieved 99% precision and average recall of 95% across 20 representative functional sites. The system uses a Support Vector Machine classifier operating on the microenvironment of physicochemical features around an amino acid. We also compared performance of our method with state-of-the-art sequence-level annotator Pfam in terms of precision, recall and localization. To our knowledge, no other functional site annotator has been rigorously evaluated against these key criteria. The software and predictive models are incorporated into the WebFEATURE service at http://feature.stanford.edu/wf4.0-beta. PMID:24632601
Precision and Accuracy of Analysis for Boron in ITP Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tovo, L.L.
'Inductively Coupled Plasma Emission Spectroscopy (ICPES) has been used by the Analytical Development Section (ADS) to measure boron in catalytic tetraphenylboron decomposition studies performed by the Waste Processing Technology (WPT) section. Analysis of these samples is complicated due to the presence of high concentrations of sodium and organic compounds. Previously, we found signal suppression in samples analyzed "as received". We suspected that the suppression was due to the high organic concentration (up to 0.01 molar organic decomposition products) in the samples. When the samples were acid digested prior to analysis, the suppression was eliminated. The precision of the reported boronmore » concentration was estimated as 10 percent based on the known precision of the inorganic boron standard used for calibration and quality control check of the ICPES analysis. However, a precision better than 10 percent was needed to evaluate ITP process operating parameters. Therefore, the purpose of this work was (1) to measure, instead of estimating, the precision of the boron measurement on ITP samples and (2) to determine the optimum precision attainable with current instrumentation.'« less
Apparatus for precision micromachining with lasers
Chang, Jim J.; Dragon, Ernest P.; Warner, Bruce E.
1998-01-01
A new material processing apparatus using a short-pulsed, high-repetition-rate visible laser for precision micromachining utilizes a near diffraction limited laser, a high-speed precision two-axis tilt-mirror for steering the laser beam, an optical system for either focusing or imaging the laser beam on the part, and a part holder that may consist of a cover plate and a back plate. The system is generally useful for precision drilling, cutting, milling and polishing of metals and ceramics, and has broad application in manufacturing precision components. Precision machining has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratios up to 1:40 have been consistently drilled with good surface finish on a variety of metals. Micromilling and microdrilling on ceramics using a 250 W copper vapor laser have also been demonstrated with good results. Materialogroaphic sections of machined parts show little (submicron scale) recast layer and heat affected zone.
Bit-Grooming: Shave Your Bits with Razor-sharp Precision
NASA Astrophysics Data System (ADS)
Zender, C. S.; Silver, J.
2017-12-01
Lossless compression can reduce climate data storage by 30-40%. Further reduction requires lossy compression that also reduces precision. Fortunately, geoscientific models and measurements generate false precision (scientifically meaningless data bits) that can be eliminated without sacrificing scientifically meaningful data. We introduce Bit Grooming, a lossy compression algorithm that removes the bloat due to false-precision, those bits and bytes beyond the meaningful precision of the data.Bit Grooming is statistically unbiased, applies to all floating point numbers, and is easy to use. Bit-Grooming reduces geoscience data storage requirements by 40-80%. We compared Bit Grooming to competitors Linear Packing, Layer Packing, and GRIB2/JPEG2000. The other compression methods have the edge in terms of compression, but Bit Grooming is the most accurate and certainly the most usable and portable.Bit Grooming provides flexible and well-balanced solutions to the trade-offs among compression, accuracy, and usability required by lossy compression. Geoscientists could reduce their long term storage costs, and show leadership in the elimination of false precision, by adopting Bit Grooming.
Open-Loop Flight Testing of COBALT Navigation and Sensor Technologies for Precise Soft Landing
NASA Technical Reports Server (NTRS)
Carson, John M., III; Restrepo, Caroline I.; Seubert, Carl R.; Amzajerdian, Farzin; Pierrottet, Diego F.; Collins, Steven M.; O'Neal, Travis V.; Stelling, Richard
2017-01-01
An open-loop flight test campaign of the NASA COBALT (CoOperative Blending of Autonomous Landing Technologies) payload was conducted onboard the Masten Xodiac suborbital rocket testbed. The payload integrates two complementary sensor technologies that together provide a spacecraft with knowledge during planetary descent and landing to precisely navigate and softly touchdown in close proximity to targeted surface locations. The two technologies are the Navigation Doppler Lidar (NDL), for high-precision velocity and range measurements, and the Lander Vision System (LVS) for map-relative state esti- mates. A specialized navigation filter running onboard COBALT fuses the NDL and LVS data in real time to produce a very precise Terrain Relative Navigation (TRN) solution that is suitable for future, autonomous planetary landing systems that require precise and soft landing capabilities. During the open-loop flight campaign, the COBALT payload acquired measurements and generated a precise navigation solution, but the Xodiac vehicle planned and executed its maneuvers based on an independent, GPS-based navigation solution. This minimized the risk to the vehicle during the integration and testing of the new navigation sensing technologies within the COBALT payload.
French Meteor Network for High Precision Orbits of Meteoroids
NASA Technical Reports Server (NTRS)
Atreya, P.; Vaubaillon, J.; Colas, F.; Bouley, S.; Gaillard, B.; Sauli, I.; Kwon, M. K.
2011-01-01
There is a lack of precise meteoroids orbit from video observations as most of the meteor stations use off-the-shelf CCD cameras. Few meteoroids orbit with precise semi-major axis are available using film photographic method. Precise orbits are necessary to compute the dust flux in the Earth s vicinity, and to estimate the ejection time of the meteoroids accurately by comparing them with the theoretical evolution model. We investigate the use of large CCD sensors to observe multi-station meteors and to compute precise orbit of these meteoroids. An ideal spatial and temporal resolution to get an accuracy to those similar of photographic plates are discussed. Various problems faced due to the use of large CCD, such as increasing the spatial and the temporal resolution at the same time and computational problems in finding the meteor position are illustrated.
Precision medicine for cancer with next-generation functional diagnostics.
Friedman, Adam A; Letai, Anthony; Fisher, David E; Flaherty, Keith T
2015-12-01
Precision medicine is about matching the right drugs to the right patients. Although this approach is technology agnostic, in cancer there is a tendency to make precision medicine synonymous with genomics. However, genome-based cancer therapeutic matching is limited by incomplete biological understanding of the relationship between phenotype and cancer genotype. This limitation can be addressed by functional testing of live patient tumour cells exposed to potential therapies. Recently, several 'next-generation' functional diagnostic technologies have been reported, including novel methods for tumour manipulation, molecularly precise assays of tumour responses and device-based in situ approaches; these address the limitations of the older generation of chemosensitivity tests. The promise of these new technologies suggests a future diagnostic strategy that integrates functional testing with next-generation sequencing and immunoprofiling to precisely match combination therapies to individual cancer patients.
[Precision medicine: new opportunities and challenges for molecular epidemiology].
Song, Jing; Hu, Yonghua
2016-04-01
Since the completion of the Human Genome Project in 2003 and the announcement of the Precision Medicine Initiative by U.S. President Barack Obama in January 2015, human beings have initially completed the " three steps" of " genomics to biology, genomics to health as well as genomics to society". As a new inter-discipline, the emergence and development of precision medicine have relied on the support and promotion from biological science, basic medicine, clinical medicine, epidemiology, statistics, sociology and information science, etc. Meanwhile, molecular epidemiology is considered to be the core power to promote precision medical as a cross discipline of epidemiology and molecular biology. This article is based on the characteristics and research progress of medicine and molecular epidemiology respectively, focusing on the contribution and significance of molecular epidemiology to precision medicine, and exploring the possible opportunities and challenges in the future.
Study of the precision guided communication of digital television
NASA Astrophysics Data System (ADS)
Liu, Lun
2012-04-01
Along with the progress and development of the digital technology, there produced the transmission of the new media by medium of such as the network, mobile phones and the digital television, while among them digital TV has the superiority of other media. The appearance and development of digital TV will induce a profound change in the broadcasting and television industry chain. This paper started with discussing the transformation of digital television in profit model, mode of operation and mode of transmission to construct the precision-guided communication theory; And then analyzes the properties and marketing nature of the precision-guided communication to make the construction of the precision-guided communication marketing mode; And put forward the implementing of the precision-guided communication marketing strategies and concrete steps; At the end of the article the author summarized four conclusions.
Air Bearings Machined On Ultra Precision, Hydrostatic CNC-Lathe
NASA Astrophysics Data System (ADS)
Knol, Pierre H.; Szepesi, Denis; Deurwaarder, Jan M.
1987-01-01
Micromachining of precision elements requires an adequate machine concept to meet the high demand of surface finish, dimensional and shape accuracy. The Hembrug ultra precision lathes have been exclusively designed with hydrostatic principles for main spindle and guideways. This concept is to be explained with some major advantages of hydrostatics compared with aerostatics at universal micromachining applications. Hembrug has originally developed the conventional Mikroturn ultra precision facing lathes, for diamond turning of computer memory discs. This first generation of machines was followed by the advanced computer numerically controlled types for machining of complex precision workpieces. One of these parts, an aerostatic bearing component has been succesfully machined on the Super-Mikroturn CNC. A case study of airbearing machining confirms the statement that a good result of the micromachining does not depend on machine performance alone, but also on the technology applied.
Cobalt: Development and Maturation of GN&C Technologies for Precision Landing
NASA Technical Reports Server (NTRS)
Carson, John M.; Restrepo, Carolina; Seubert, Carl; Amzajerdian, Farzin
2016-01-01
The CoOperative Blending of Autonomous Landing Technologies (COBALT) instrument is a terrestrial test platform for development and maturation of guidance, navigation and control (GN&C) technologies for precision landing. The project is developing a third-generation Langley Research Center (LaRC) navigation doppler lidar (NDL) for ultra-precise velocity and range measurements, which will be integrated and tested with the Jet Propulsion Laboratory (JPL) lander vision system (LVS) for terrain relative navigation (TRN) position estimates. These technologies together provide precise navigation knowledge that is critical for a controlled and precise touchdown. The COBALT hardware will be integrated in 2017 into the GN&C subsystem of the Xodiac rocket-propulsive vertical test bed (VTB) developed by Masten Space Systems, and two terrestrial flight campaigns will be conducted: one open-loop (i.e., passive) and one closed-loop (i.e., active).
Jiang, Biao; Jia, Yan; He, Congfen
2018-05-11
Traditional skincare involves the subjective classification of skin into 4 categories (oily, dry, mixed, and neutral) prior to skin treatment. Following the development of noninvasive methods in skin and skin imaging technology, scientists have developed efficacy-based skincare products based on the physiological characteristics of skin under different conditions. Currently, the emergence of skinomics and systems biology has facilitated the development of precision skincare. In this article, the evolution of skincare based on the physiological states of the skin (from traditional skincare and efficacy-based skincare to precision skincare) is described. In doing so, we highlight skinomics and systems biology, with particular emphasis on the importance of skin lipidomics and microbiomes in precision skincare. The emerging trends of precision skincare are anticipated. © 2018 Wiley Periodicals, Inc.
[Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system].
Krimmel, M; Kluba, S; Dietz, K; Reinert, S
2005-03-01
The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.
Dong, R H; Qin, C C; Qiu, X; Yan, X; Yu, M; Cui, L; Zhou, Y; Zhang, H D; Jiang, X Y; Long, Y Z
2015-12-14
The side effects or toxicity of cyanoacrylate used in vivo have been argued since its first application in wound closure. We propose an airflow-assisted in situ precision electrospinning apparatus as an applicator and make a detailed comparison with traditional spraying via in vitro and in vivo experiments. This novel method can not only improve operational performance and safety by precisely depositing cyanoacrylate fibers onto a wound, but significantly reduce the dosage of cyanoacrylate by almost 80%. A white blood cell count, liver function test and histological analysis prove that the in situ precision electrospinning applicator produces a better postoperative outcome, e.g., minor hepatocyte injury, moderate inflammation and the significant ability for liver regeneration. This in situ precision electrospinning method may thus dramatically broaden both civilian and military applications of cyanoacrylates.
Equity and Value in 'Precision Medicine'.
Gray, Muir; Lagerberg, Tyra; Dombrádi, Viktor
2017-04-01
Precision medicine carries huge potential in the treatment of many diseases, particularly those with high-penetrance monogenic underpinnings. However, precision medicine through genomic technologies also has ethical implications. We will define allocative, personal, and technical value ('triple value') in healthcare and how this relates to equity. Equity is here taken to be implicit in the concept of triple value in countries that have publicly funded healthcare systems. It will be argued that precision medicine risks concentrating resources to those that already experience greater access to healthcare and power in society, nationally as well as globally. Healthcare payers, clinicians, and patients must all be involved in optimising the potential of precision medicine, without reducing equity. Throughout, the discussion will refer to the NHS RightCare Programme, which is a national initiative aiming to improve value and equity in the context of NHS England.
Fundamental limits of scintillation detector timing precision
NASA Astrophysics Data System (ADS)
Derenzo, Stephen E.; Choong, Woon-Seng; Moses, William W.
2014-07-01
In this paper we review the primary factors that affect the timing precision of a scintillation detector. Monte Carlo calculations were performed to explore the dependence of the timing precision on the number of photoelectrons, the scintillator decay and rise times, the depth of interaction uncertainty, the time dispersion of the optical photons (modeled as an exponential decay), the photodetector rise time and transit time jitter, the leading-edge trigger level, and electronic noise. The Monte Carlo code was used to estimate the practical limits on the timing precision for an energy deposition of 511 keV in 3 mm × 3 mm × 30 mm Lu2SiO5:Ce and LaBr3:Ce crystals. The calculated timing precisions are consistent with the best experimental literature values. We then calculated the timing precision for 820 cases that sampled scintillator rise times from 0 to 1.0 ns, photon dispersion times from 0 to 0.2 ns, photodetector time jitters from 0 to 0.5 ns fwhm, and A from 10 to 10 000 photoelectrons per ns decay time. Since the timing precision R was found to depend on A-1/2 more than any other factor, we tabulated the parameter B, where R = BA-1/2. An empirical analytical formula was found that fit the tabulated values of B with an rms deviation of 2.2% of the value of B. The theoretical lower bound of the timing precision was calculated for the example of 0.5 ns rise time, 0.1 ns photon dispersion, and 0.2 ns fwhm photodetector time jitter. The lower bound was at most 15% lower than leading-edge timing discrimination for A from 10 to 10 000 photoelectrons ns-1. A timing precision of 8 ps fwhm should be possible for an energy deposition of 511 keV using currently available photodetectors if a theoretically possible scintillator were developed that could produce 10 000 photoelectrons ns-1.
Fundamental Limits of Scintillation Detector Timing Precision
Derenzo, Stephen E.; Choong, Woon-Seng; Moses, William W.
2014-01-01
In this paper we review the primary factors that affect the timing precision of a scintillation detector. Monte Carlo calculations were performed to explore the dependence of the timing precision on the number of photoelectrons, the scintillator decay and rise times, the depth of interaction uncertainty, the time dispersion of the optical photons (modeled as an exponential decay), the photodetector rise time and transit time jitter, the leading-edge trigger level, and electronic noise. The Monte Carlo code was used to estimate the practical limits on the timing precision for an energy deposition of 511 keV in 3 mm × 3 mm × 30 mm Lu2SiO5:Ce and LaBr3:Ce crystals. The calculated timing precisions are consistent with the best experimental literature values. We then calculated the timing precision for 820 cases that sampled scintillator rise times from 0 to 1.0 ns, photon dispersion times from 0 to 0.2 ns, photodetector time jitters from 0 to 0.5 ns fwhm, and A from 10 to 10,000 photoelectrons per ns decay time. Since the timing precision R was found to depend on A−1/2 more than any other factor, we tabulated the parameter B, where R = BA−1/2. An empirical analytical formula was found that fit the tabulated values of B with an rms deviation of 2.2% of the value of B. The theoretical lower bound of the timing precision was calculated for the example of 0.5 ns rise time, 0.1 ns photon dispersion, and 0.2 ns fwhm photodetector time jitter. The lower bound was at most 15% lower than leading-edge timing discrimination for A from 10 to 10,000 photoelectrons/ns. A timing precision of 8 ps fwhm should be possible for an energy deposition of 511 keV using currently available photodetectors if a theoretically possible scintillator were developed that could produce 10,000 photoelectrons/ns. PMID:24874216
Direct Comparison of the Precision of the New Hologic Horizon Model With the Old Discovery Model.
Whittaker, LaTarsha G; McNamara, Elizabeth A; Vath, Savoun; Shaw, Emily; Malabanan, Alan O; Parker, Robert A; Rosen, Harold N
2017-11-22
Previous publications suggested that the precision of the new Hologic Horizon densitometer might be better than that of the previous Discovery model, but these observations were confounded by not using the same participants and technologists on both densitometers. We sought to study this issue methodically by measuring in vivo precision in both densitometers using the same patients and technologists. Precision studies for the Horizon and Discovery models were done by acquiring spine, hip, and forearm bone mineral density twice on 30 participants. The set of 4 scans on each participant (2 on the Discovery, 2 on the Horizon) was acquired by the same technologist using the same scanning mode. The pairs of data were used to calculate the least significant change according to the International Society for Clinical Densitometry guidelines. The significance of the difference between least significant changes was assessed using a Wilcoxon signed-rank test of the difference between the mean square error of the absolute value of the differences between paired measurements on the Discovery (Δ-Discovery) and the mean square error of the absolute value of the differences between paired measurements on the Horizon (Δ-Horizon). At virtually all anatomic sites, there was a nonsignificant trend for the precision to be better for the Horizon than for the Discovery. As more vertebrae were excluded from analysis, the precision deteriorated on both densitometers. The precision between densitometers was almost identical when reporting only 1 vertebral body. (1) There was a nonsignificant trend for greater precision on the new Hologic Horizon compared with the older Discovery model. (2) The difference in precision of the spine bone mineral density between the Horizon and the Discovery models decreases as fewer vertebrae are included. (3) These findings are substantially similar to previously published results which had not controlled as well for confounding from using different subjects and technologists. Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
The European Society for Medical Oncology (ESMO) Precision Medicine Glossary.
Yates, L R; Seoane, J; Le Tourneau, C; Siu, L L; Marais, R; Michiels, S; Soria, J C; Campbell, P; Normanno, N; Scarpa, A; Reis-Filho, J S; Rodon, J; Swanton, C; Andre, F
2018-01-01
Precision medicine is rapidly evolving within the field of oncology and has brought many new concepts and terminologies that are often poorly defined when first introduced, which may subsequently lead to miscommunication within the oncology community. The European Society for Medical Oncology (ESMO) recognises these challenges and is committed to support the adoption of precision medicine in oncology. To add clarity to the language used by oncologists and basic scientists within the context of precision medicine, the ESMO Translational Research and Personalised Medicine Working Group has developed a standardised glossary of relevant terms. Relevant terms for inclusion in the glossary were identified via an ESMO member survey conducted in Autumn 2016, and by the ESMO Translational Research and Personalised Medicine Working Group members. Each term was defined by experts in the field, discussed and, if necessary, modified by the Working Group before reaching consensus approval. A literature search was carried out to determine which of the terms, 'precision medicine' and 'personalised medicine', is most appropriate to describe this field. A total of 43 terms are included in the glossary, grouped into five main themes-(i) mechanisms of decision, (ii) characteristics of molecular alterations, (iii) tumour characteristics, (iv) clinical trials and statistics and (v) new research tools. The glossary classes 'precision medicine' or 'personalised medicine' as technically interchangeable but the term 'precision medicine' is favoured as it more accurately reflects the highly precise nature of new technologies that permit base pair resolution dissection of cancer genomes and is less likely to be misinterpreted. The ESMO Precision Medicine Glossary provides a resource to facilitate consistent communication in this field by clarifying and raising awareness of the language employed in cancer research and oncology practice. The glossary will be a dynamic entity, undergoing expansion and refinement over the coming years. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology. [br]All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Performance Evaluation of Real-Time Precise Point Positioning Method
NASA Astrophysics Data System (ADS)
Alcay, Salih; Turgut, Muzeyyen
2017-12-01
Post-Processed Precise Point Positioning (PPP) is a well-known zero-difference positioning method which provides accurate and precise results. After the experimental tests, IGS Real Time Service (RTS) officially provided real time orbit and clock products for the GNSS community that allows real-time (RT) PPP applications. Different software packages can be used for RT-PPP. In this study, in order to evaluate the performance of RT-PPP, 3 IGS stations are used. Results, obtained by using BKG Ntrip Client (BNC) Software v2.12, are examined in terms of both accuracy and precision.
Precision and manufacturing at the Lawrence Livermore National Laboratory
NASA Technical Reports Server (NTRS)
Saito, Theodore T.; Wasley, Richard J.; Stowers, Irving F.; Donaldson, Robert R.; Thompson, Daniel C.
1994-01-01
Precision Engineering is one of the Lawrence Livermore National Laboratory's core strengths. This paper discusses the past and present current technology transfer efforts of LLNL's Precision Engineering program and the Livermore Center for Advanced Manufacturing and Productivity (LCAMP). More than a year ago the Precision Machine Commercialization project embodied several successful methods of transferring high technology from the National Laboratories to industry. Currently, LCAMP has already demonstrated successful technology transfer and is involved in a broad spectrum of current programs. In addition, this paper discusses other technologies ripe for future transition including the Large Optics Diamond Turning Machine.
Precision manufacturing for clinical-quality regenerative medicines.
Williams, David J; Thomas, Robert J; Hourd, Paul C; Chandra, Amit; Ratcliffe, Elizabeth; Liu, Yang; Rayment, Erin A; Archer, J Richard
2012-08-28
Innovations in engineering applied to healthcare make a significant difference to people's lives. Market growth is guaranteed by demographics. Regulation and requirements for good manufacturing practice-extreme levels of repeatability and reliability-demand high-precision process and measurement solutions. Emerging technologies using living biological materials add complexity. This paper presents some results of work demonstrating the precision automated manufacture of living materials, particularly the expansion of populations of human stem cells for therapeutic use as regenerative medicines. The paper also describes quality engineering techniques for precision process design and improvement, and identifies the requirements for manufacturing technology and measurement systems evolution for such therapies.
Haiyang, Yu; Tian, Luo
2016-06-01
Target restoration space (TRS) is the most precise space required for designing optimal prosthesis. TRS consists of an internal or external tooth space to confirm the esthetics and function of the final restoration. Therefore, assisted with quantitive analysis transfer, TRS quantitative analysis is a significant improvement for minimum tooth preparation. This article presents TRS quantity-related measurement, analysis, transfer, and internal relevance of three TR. classifications. Results reveal the close bond between precision and minimally invasive treatment. This study can be used to improve the comprehension and execution of precise esthetic prosthodontics.
Innovation, productivity, and pricing: Capturing value from precision medicine technology in Canada.
Emery, J C Herbert; Zwicker, Jennifer D
2017-07-01
For new technology and innovation such as precision medicine to become part of the solution for the fiscal sustainability of Canadian Medicare, decision-makers need to change how services are priced rather than trying to restrain emerging technologies like precision medicine for short-term cost savings. If provincial public payers shift their thinking to be public purchasers, value considerations would direct reform of the reimbursement system to have prices that adjust with technologically driven productivity gains. This strategic shift in thinking is necessary if Canadians are to benefit from the promised benefits of innovations like precision medicine.
Precision and manufacturing at the Lawrence Livermore National Laboratory
NASA Astrophysics Data System (ADS)
Saito, Theodore T.; Wasley, Richard J.; Stowers, Irving F.; Donaldson, Robert R.; Thompson, Daniel C.
1994-02-01
Precision Engineering is one of the Lawrence Livermore National Laboratory's core strengths. This paper discusses the past and present current technology transfer efforts of LLNL's Precision Engineering program and the Livermore Center for Advanced Manufacturing and Productivity (LCAMP). More than a year ago the Precision Machine Commercialization project embodied several successful methods of transferring high technology from the National Laboratories to industry. Currently, LCAMP has already demonstrated successful technology transfer and is involved in a broad spectrum of current programs. In addition, this paper discusses other technologies ripe for future transition including the Large Optics Diamond Turning Machine.
Multi-GNSS real-time precise orbit/clock/UPD products and precise positioning service at GFZ
NASA Astrophysics Data System (ADS)
Li, Xingxing; Ge, Maorong; Liu, Yang; Fritsche, Mathias; Wickert, Jens; Schuh, Harald
2016-04-01
The rapid development of multi-constellation GNSSs (Global Navigation Satellite Systems, e.g., BeiDou, Galileo, GLONASS, GPS) and the IGS (International GNSS Service) Multi-GNSS Experiment (MGEX) bring great opportunities and challenges for real-time precise positioning service. In this contribution, we present a GPS+GLONASS+BeiDou+Galileo four-system model to fully exploit the observations of all these four navigation satellite systems for real-time precise orbit determination, clock estimation and positioning. A rigorous multi-GNSS analysis is performed to achieve the best possible consistency by processing the observations from different GNSS together in one common parameter estimation procedure. Meanwhile, an efficient multi-GNSS real-time precise positioning service system is designed and demonstrated by using the Multi-GNSS Experiment (MGEX) and International GNSS Service (IGS) data streams including stations all over the world. The addition of the BeiDou, Galileo and GLONASS systems to the standard GPS-only processing, reduces the convergence time almost by 70%, while the positioning accuracy is improved by about 25%. Some outliers in the GPS-only solutions vanish when multi-GNSS observations are processed simultaneous. The availability and reliability of GPS precise positioning decrease dramatically as the elevation cutoff increases. However, the accuracy of multi-GNSS precise point positioning (PPP) is hardly decreased and few centimeters are still achievable in the horizontal components even with 40° elevation cutoff.
Principles of precision medicine in stroke.
Hinman, Jason D; Rost, Natalia S; Leung, Thomas W; Montaner, Joan; Muir, Keith W; Brown, Scott; Arenillas, Juan F; Feldmann, Edward; Liebeskind, David S
2017-01-01
The era of precision medicine has arrived and conveys tremendous potential, particularly for stroke neurology. The diagnosis of stroke, its underlying aetiology, theranostic strategies, recurrence risk and path to recovery are populated by a series of highly individualised questions. Moreover, the phenotypic complexity of a clinical diagnosis of stroke makes a simple genetic risk assessment only partially informative on an individual basis. The guiding principles of precision medicine in stroke underscore the need to identify, value, organise and analyse the multitude of variables obtained from each individual to generate a precise approach to optimise cerebrovascular health. Existing data may be leveraged with novel technologies, informatics and practical clinical paradigms to apply these principles in stroke and realise the promise of precision medicine. Importantly, precision medicine in stroke will only be realised once efforts to collect, value and synthesise the wealth of data collected in clinical trials and routine care starts. Stroke theranostics, the ultimate vision of synchronising tailored therapeutic strategies based on specific diagnostic data, demand cerebrovascular expertise on big data approaches to clinically relevant paradigms. This review considers such challenges and delineates the principles on a roadmap for rational application of precision medicine to stroke and cerebrovascular health. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
NASA Astrophysics Data System (ADS)
Inamori, Takaya; Hosonuma, Takayuki; Ikari, Satoshi; Saisutjarit, Phongsatorn; Sako, Nobutada; Nakasuka, Shinichi
2015-02-01
Recently, small satellites have been employed in various satellite missions such as astronomical observation and remote sensing. During these missions, the attitudes of small satellites should be stabilized to a higher accuracy to obtain accurate science data and images. To achieve precise attitude stabilization, these small satellites should estimate their attitude rate under the strict constraints of mass, space, and cost. This research presents a new method for small satellites to precisely estimate angular rate using star blurred images by employing a mission telescope to achieve precise attitude stabilization. In this method, the angular velocity is estimated by assessing the quality of a star image, based on how blurred it appears to be. Because the proposed method utilizes existing mission devices, a satellite does not require additional precise rate sensors, which makes it easier to achieve precise stabilization given the strict constraints possessed by small satellites. The research studied the relationship between estimation accuracy and parameters used to achieve an attitude rate estimation, which has a precision greater than 1 × 10-6 rad/s. The method can be applied to all attitude sensors, which use optics systems such as sun sensors and star trackers (STTs). Finally, the method is applied to the nano astrometry satellite Nano-JASMINE, and we investigate the problems that are expected to arise with real small satellites by performing numerical simulations.
Optimization of deformation monitoring networks using finite element strain analysis
NASA Astrophysics Data System (ADS)
Alizadeh-Khameneh, M. Amin; Eshagh, Mehdi; Jensen, Anna B. O.
2018-04-01
An optimal design of a geodetic network can fulfill the requested precision and reliability of the network, and decrease the expenses of its execution by removing unnecessary observations. The role of an optimal design is highlighted in deformation monitoring network due to the repeatability of these networks. The core design problem is how to define precision and reliability criteria. This paper proposes a solution, where the precision criterion is defined based on the precision of deformation parameters, i. e. precision of strain and differential rotations. A strain analysis can be performed to obtain some information about the possible deformation of a deformable object. In this study, we split an area into a number of three-dimensional finite elements with the help of the Delaunay triangulation and performed the strain analysis on each element. According to the obtained precision of deformation parameters in each element, the precision criterion of displacement detection at each network point is then determined. The developed criterion is implemented to optimize the observations from the Global Positioning System (GPS) in Skåne monitoring network in Sweden. The network was established in 1989 and straddled the Tornquist zone, which is one of the most active faults in southern Sweden. The numerical results show that 17 out of all 21 possible GPS baseline observations are sufficient to detect minimum 3 mm displacement at each network point.
Yousefi-Nooraie, Reza; Irani, Shirin; Mortaz-Hedjri, Soroush; Shakiba, Behnam
2013-10-01
The aim of this study was to compare the performance of three search methods in the retrieval of relevant clinical trials from PubMed to answer specific clinical questions. Included studies of a sample of 100 Cochrane reviews which recorded in PubMed were considered as the reference standard. The search queries were formulated based on the systematic review titles. Precision, recall and number of retrieved records for limiting the results to clinical trial publication type, and using sensitive and specific clinical queries filters were compared. The number of keywords, presence of specific names of intervention and syndrome in the search keywords were used in a model to predict the recalls and precisions. The Clinical queries-sensitive search strategy retrieved the largest number of records (33) and had the highest recall (41.6%) and lowest precision (4.8%). The presence of specific intervention name was the only significant predictor of all recalls and precisions (P = 0.016). The recall and precision of combination of simple clinical search queries and methodological search filters to find clinical trials in various subjects were considerably low. The limit field strategy yielded in higher precision and fewer retrieved records and approximately similar recall, compared with the clinical queries-sensitive strategy. Presence of specific intervention name in the search keywords increased both recall and precision. © 2010 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Hahn, Gitte Holst; Christensen, Karl Bang; Leung, Terence S.; Greisen, Gorm
2010-05-01
Coherence between spontaneous fluctuations in arterial blood pressure (ABP) and the cerebral near-infrared spectroscopy signal can detect cerebral autoregulation. Because reliable measurement depends on signals with high signal-to-noise ratio, we hypothesized that coherence is more precisely determined when fluctuations in ABP are large rather than small. Therefore, we investigated whether adjusting for variability in ABP (variabilityABP) improves precision. We examined the impact of variabilityABP within the power spectrum in each measurement and between repeated measurements in preterm infants. We also examined total monitoring time required to discriminate among infants with a simulation study. We studied 22 preterm infants (GA<30) yielding 215 10-min measurements. Surprisingly, adjusting for variabilityABP within the power spectrum did not improve the precision. However, adjusting for the variabilityABP among repeated measurements (i.e., weighting measurements with high variabilityABP in favor of those with low) improved the precision. The evidence of drift in individual infants was weak. Minimum monitoring time needed to discriminate among infants was 1.3-3.7 h. Coherence analysis in low frequencies (0.04-0.1 Hz) had higher precision and statistically more power than in very low frequencies (0.003-0.04 Hz). In conclusion, a reliable detection of cerebral autoregulation takes hours and the precision is improved by adjusting for variabilityABP between repeated measurements.
VIEW OF PRECISION EQUIPMENT USED IN STAINLESS COMPONENT MANUFACTURING. THE ...
VIEW OF PRECISION EQUIPMENT USED IN STAINLESS COMPONENT MANUFACTURING. THE FACILITY WAS DESCRIBED AS THE MOST MODERN NON-NUCLEAR MANUFACTURING BUILDING IN THE U.S. DEPARTMENT OF ENERGY COMPLEX, WITH MANY PRECISION INSTRUMENTS. (9/21/83) - Rocky Flats Plant, Stainless Steel & Non-Nuclear Components Manufacturing, Southeast corner of intersection of Cottonwood & Third Avenues, Golden, Jefferson County, CO
Precise Time - Naval Oceanography Portal
section Advanced Search... Sections Home Time Earth Orientation Astronomy Meteorology Oceanography Ice You are here: Home ⺠USNO ⺠Precise Time USNO Logo USNO Navigation Master Clock GPS Display Clocks TWSTT Telephone Time NTP Info Precise Time The U. S. Naval Observatory is charged with maintaining the
ERIC Educational Resources Information Center
Igoe, D. P.; Parisi, A. V.; Wagner, S.
2017-01-01
Smartphones used as tools provide opportunities for the teaching of the concepts of accuracy and precision and the mathematical concept of arctan. The accuracy and precision of a trigonometric experiment using entirely mechanical tools is compared to one using electronic tools, such as a smartphone clinometer application and a laser pointer. This…
The Paradox of Abstraction: Precision Versus Concreteness
ERIC Educational Resources Information Center
Iliev, Rumen; Axelrod, Robert
2017-01-01
We introduce a novel measure of abstractness based on the amount of information of a concept computed from its position in a semantic taxonomy. We refer to this measure as "precision". We propose two alternative ways to measure precision, one based on the path length from a concept to the root of the taxonomic tree, and another one based…
GABA-Mediated Presynaptic Inhibition Is Required for Precision of Long-Term Memory
ERIC Educational Resources Information Center
Cullen, Patrick K.; Dulka, Brooke N.; Ortiz, Samantha; Riccio, David C.; Jasnow, Aaron M.
2014-01-01
Though much attention has been given to the neural structures that underlie the long-term consolidation of contextual memories, little is known about the mechanisms responsible for the maintenance of memory precision. Here, we demonstrate a rapid time-dependent decline in memory precision in GABA [subscript B(1a)] receptor knockout mice. First, we…
Magnan, Morris A; Maklebust, Joann
2008-01-01
To evaluate the effect of Web-based Braden Scale training on the reliability and precision of pressure ulcer risk assessments made by registered nurses (RN) working in acute care settings. Pretest-posttest, 2-group, quasi-experimental design. Five hundred Braden Scale risk assessments were made on 102 acute care patients deemed to be at various levels of risk for pressure ulceration. Assessments were made by RNs working in acute care hospitals at 3 different medical centers where the Braden Scale was in regular daily use (2 medical centers) or new to the setting (1 medical center). The Braden Scale for Predicting Pressure Sore Risk was used to guide pressure ulcer risk assessments. A Web-based version of the Detroit Medical Center Braden Scale Computerized Training Module was used to teach nurses correct use of the Braden Scale and selection of risk-based pressure ulcer prevention interventions. In the aggregate, RN generated reliable Braden Scale pressure ulcer risk assessments 65% of the time after training. The effect of Web-based Braden Scale training on reliability and precision of assessments varied according to familiarity with the scale. With training, new users of the scale made reliable assessments 84% of the time and significantly improved precision of their assessments. The reliability and precision of Braden Scale risk assessments made by its regular users was unaffected by training. Technology-assisted Braden Scale training improved both reliability and precision of risk assessments made by new users of the scale, but had virtually no effect on the reliability or precision of risk assessments made by regular users of the instrument. Further research is needed to determine best approaches for improving reliability and precision of Braden Scale assessments made by its regular users.
Composite adaptive control of belt polishing force for aero-engine blade
NASA Astrophysics Data System (ADS)
Zhsao, Pengbing; Shi, Yaoyao
2013-09-01
The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and significantly reduces the surface roughness.
Dairy farmers with larger herd sizes adopt more precision dairy technologies.
Gargiulo, J I; Eastwood, C R; Garcia, S C; Lyons, N A
2018-06-01
An increase in the average herd size on Australian dairy farms has also increased the labor and animal management pressure on farmers, thus potentially encouraging the adoption of precision technologies for enhanced management control. A survey was undertaken in 2015 in Australia to identify the relationship between herd size, current precision technology adoption, and perception of the future of precision technologies. Additionally, differences between farmers and service providers in relation to perception of future precision technology adoption were also investigated. Responses from 199 dairy farmers, and 102 service providers, were collected between May and August 2015 via an anonymous Internet-based questionnaire. Of the 199 dairy farmer responses, 10.4% corresponded to farms that had fewer than 150 cows, 37.7% had 151 to 300 cows, 35.5% had 301 to 500 cows; 6.0% had 501 to 700 cows, and 10.4% had more than 701 cows. The results showed that farmers with more than 500 cows adopted between 2 and 5 times more specific precision technologies, such as automatic cup removers, automatic milk plant wash systems, electronic cow identification systems and herd management software, when compared with smaller farms. Only minor differences were detected in perception of the future of precision technologies between either herd size or farmers and service providers. In particular, service providers expected a higher adoption of automatic milking and walk over weighing systems than farmers. Currently, the adoption of precision technology has mostly been of the type that reduces labor needs; however, respondents indicated that by 2025 adoption of data capturing technology for monitoring farm system parameters would be increased. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A
2010-12-01
The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.
Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems
NASA Technical Reports Server (NTRS)
Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.
2015-01-01
Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.
NASA Astrophysics Data System (ADS)
Du, W.; Chen, L.; Xie, H.; Hai, G.; Zhang, S.; Tong, X.
2017-09-01
This paper analyzes the precision and deviation of elevations acquired from Envisat and The Ice, Cloud and Land Elevation Satellite (ICESat) over typical ice gaining and losing regions, i.e. Lambert-Amery System (LAS) in east Antarctica, and Amundsen Sea Sector (ASS) in west Antarctica, during the same period from 2003 to 2008. We used GLA12 dataset of ICESat and Level 2 data of Envisat. Data preprocessing includes data filtering, projection transformation and track classification. Meanwhile, the slope correction is applied to Envisat data and saturation correction for ICESat data. Then the crossover analysis was used to obtain the crossing points of the ICESat tracks, Envisat tracks and ICESat-Envisat tracks separately. The two tracks we chose for cross-over analysis should be in the same campaign for ICESat (within 33 days) or the same cycle for Envisat (within 35 days).The standard deviation of a set of elevation residuals at time-coincident crossovers is calculated as the precision of each satellite while the mean value is calculated as the deviation of ICESat-Envisat. Generally, the ICESat laser altimeter gets a better precision than the Envisat radar altimeter. For Amundsen Sea Sector, the ICESat precision is found to vary from 8.9 cm to 17 cm and the Envisat precision varies from 0.81 m to 1.57 m. For LAS area, the ICESat precision is found to vary from 6.7 cm to 14.3 cm and the Envisat precision varies from 0.46 m to 0.81 m. Comparison result between Envisat and ICESat elevations shows a mean difference of 0.43 ±7.14 m for Amundsen Sea Sector and 0.53 ± 1.23 m over LAS.
Cramer, Emily
2016-01-01
Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598
MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times
NASA Technical Reports Server (NTRS)
Grampp, S.; Majumdar, S.; Jergas, M.; Lang, P.; Gies, A.; Genant, H. K.
1995-01-01
The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.
Haslem, Derrick S.; Van Norman, S. Burke; Fulde, Gail; Knighton, Andrew J.; Belnap, Tom; Butler, Allison M.; Rhagunath, Sharanya; Newman, David; Gilbert, Heather; Tudor, Brian P.; Lin, Karen; Stone, Gary R.; Loughmiller, David L.; Mishra, Pravin J.; Srivastava, Rajendu; Ford, James M.; Nadauld, Lincoln D.
2017-01-01
Purpose: The advent of genomic diagnostic technologies such as next-generation sequencing has recently enabled the use of genomic information to guide targeted treatment in patients with cancer, an approach known as precision medicine. However, clinical outcomes, including survival and the cost of health care associated with precision cancer medicine, have been challenging to measure and remain largely unreported. Patients and Methods: We conducted a matched cohort study of 72 patients with metastatic cancer of diverse subtypes in the setting of a large, integrated health care delivery system. We analyzed the outcomes of 36 patients who received genomic testing and targeted therapy (precision cancer medicine) between July 1, 2013, and January 31, 2015, compared with 36 historical control patients who received standard chemotherapy (n = 29) or best supportive care (n = 7). Results: The average progression-free survival was 22.9 weeks for the precision medicine group and 12.0 weeks for the control group (P = .002) with a hazard ratio of 0.47 (95% CI, 0.29 to 0.75) when matching on age, sex, histologic diagnosis, and previous lines of treatment. In a subset analysis of patients who received all care within the Intermountain Healthcare system (n = 44), per patient charges per week were $4,665 in the precision treatment group and $5,000 in the control group (P = .126). Conclusion: These findings suggest that precision cancer medicine may improve survival for patients with refractory cancer without increasing health care costs. Although the results of this study warrant further validation, this precision medicine approach may be a viable option for patients with advanced cancer. PMID:27601506
Haslem, Derrick S; Van Norman, S Burke; Fulde, Gail; Knighton, Andrew J; Belnap, Tom; Butler, Allison M; Rhagunath, Sharanya; Newman, David; Gilbert, Heather; Tudor, Brian P; Lin, Karen; Stone, Gary R; Loughmiller, David L; Mishra, Pravin J; Srivastava, Rajendu; Ford, James M; Nadauld, Lincoln D
2017-02-01
The advent of genomic diagnostic technologies such as next-generation sequencing has recently enabled the use of genomic information to guide targeted treatment in patients with cancer, an approach known as precision medicine. However, clinical outcomes, including survival and the cost of health care associated with precision cancer medicine, have been challenging to measure and remain largely unreported. We conducted a matched cohort study of 72 patients with metastatic cancer of diverse subtypes in the setting of a large, integrated health care delivery system. We analyzed the outcomes of 36 patients who received genomic testing and targeted therapy (precision cancer medicine) between July 1, 2013, and January 31, 2015, compared with 36 historical control patients who received standard chemotherapy (n = 29) or best supportive care (n = 7). The average progression-free survival was 22.9 weeks for the precision medicine group and 12.0 weeks for the control group ( P = .002) with a hazard ratio of 0.47 (95% CI, 0.29 to 0.75) when matching on age, sex, histologic diagnosis, and previous lines of treatment. In a subset analysis of patients who received all care within the Intermountain Healthcare system (n = 44), per patient charges per week were $4,665 in the precision treatment group and $5,000 in the control group ( P = .126). These findings suggest that precision cancer medicine may improve survival for patients with refractory cancer without increasing health care costs. Although the results of this study warrant further validation, this precision medicine approach may be a viable option for patients with advanced cancer.
Whilde, Jenny; Martindale, Mark Q; Duffy, David J
2017-05-01
The current species extinction crisis is being exacerbated by an increased rate of emergence of epizootic disease. Human-induced factors including habitat degradation, loss of biodiversity and wildlife population reductions resulting in reduced genetic variation are accelerating disease emergence. Novel, efficient and effective approaches are required to combat these epizootic events. Here, we present the case for the application of human precision medicine approaches to wildlife medicine in order to enhance species conservation efforts. We consider how the precision medicine revolution, coupled with the advances made in genomics, may provide a powerful and feasible approach to identifying and treating wildlife diseases in a targeted, effective and streamlined manner. A number of case studies of threatened species are presented which demonstrate the applicability of precision medicine to wildlife conservation, including sea turtles, amphibians and Tasmanian devils. These examples show how species conservation could be improved by using precision medicine techniques to determine novel treatments and management strategies for the specific medical conditions hampering efforts to restore population levels. Additionally, a precision medicine approach to wildlife health has in turn the potential to provide deeper insights into human health and the possibility of stemming and alleviating the impacts of zoonotic diseases. The integration of the currently emerging Precision Medicine Initiative with the concepts of EcoHealth (aiming for sustainable health of people, animals and ecosystems through transdisciplinary action research) and One Health (recognizing the intimate connection of humans, animal and ecosystem health and addressing a wide range of risks at the animal-human-ecosystem interface through a coordinated, collaborative, interdisciplinary approach) has great potential to deliver a deeper and broader interdisciplinary-based understanding of both wildlife and human diseases. © 2016 John Wiley & Sons Ltd.
Toward Space-like Photometric Precision from the Ground with Beam-shaping Diffusers
NASA Astrophysics Data System (ADS)
Stefansson, Gudmundur; Mahadevan, Suvrath; Hebb, Leslie; Wisniewski, John; Huehnerhoff, Joseph; Morris, Brett; Halverson, Sam; Zhao, Ming; Wright, Jason; O'rourke, Joseph; Knutson, Heather; Hawley, Suzanne; Kanodia, Shubham; Li, Yiting; Hagen, Lea M. Z.; Liu, Leo J.; Beatty, Thomas; Bender, Chad; Robertson, Paul; Dembicky, Jack; Gray, Candace; Ketzeback, William; McMillan, Russet; Rudyk, Theodore
2017-10-01
We demonstrate a path to hitherto unachievable differential photometric precisions from the ground, both in the optical and near-infrared (NIR), using custom-fabricated beam-shaping diffusers produced using specialized nanofabrication techniques. Such diffusers mold the focal plane image of a star into a broad and stable top-hat shape, minimizing photometric errors due to non-uniform pixel response, atmospheric seeing effects, imperfect guiding, and telescope-induced variable aberrations seen in defocusing. This PSF reshaping significantly increases the achievable dynamic range of our observations, increasing our observing efficiency and thus better averages over scintillation. Diffusers work in both collimated and converging beams. We present diffuser-assisted optical observations demonstrating {62}-16+26 ppm precision in 30 minute bins on a nearby bright star 16 Cygni A (V = 5.95) using the ARC 3.5 m telescope—within a factor of ˜2 of Kepler's photometric precision on the same star. We also show a transit of WASP-85-Ab (V = 11.2) and TRES-3b (V = 12.4), where the residuals bin down to {180}-41+66 ppm in 30 minute bins for WASP-85-Ab—a factor of ˜4 of the precision achieved by the K2 mission on this target—and to 101 ppm for TRES-3b. In the NIR, where diffusers may provide even more significant improvements over the current state of the art, our preliminary tests demonstrated {137}-36+64 ppm precision for a K S = 10.8 star on the 200 inch Hale Telescope. These photometric precisions match or surpass the expected photometric precisions of TESS for the same magnitude range. This technology is inexpensive, scalable, easily adaptable, and can have an important and immediate impact on the observations of transits and secondary eclipses of exoplanets.
NASA Astrophysics Data System (ADS)
Wray, J. D.
2003-05-01
The robotic observatory telescope must point precisely on the target object, and then track autonomously to a fraction of the FWHM of the system PSF for durations of ten to twenty minutes or more. It must retain this precision while continuing to function at rates approaching thousands of observations per night for all its years of useful life. These stringent requirements raise new challenges unique to robotic telescope systems design. Critical design considerations are driven by the applicability of the above requirements to all systems of the robotic observatory, including telescope and instrument systems, telescope-dome enclosure systems, combined electrical and electronics systems, environmental (e.g. seeing) control systems and integrated computer control software systems. Traditional telescope design considerations include the effects of differential thermal strain, elastic flexure, plastic flexure and slack or backlash with respect to focal stability, optical alignment and angular pointing and tracking precision. Robotic observatory design must holistically encapsulate these traditional considerations within the overall objective of maximized long-term sustainable precision performance. This overall objective is accomplished through combining appropriate mechanical and dynamical system characteristics with a full-time real-time telescope mount model feedback computer control system. Important design considerations include: identifying and reducing quasi-zero-backlash; increasing size to increase precision; directly encoding axis shaft rotation; pointing and tracking operation via real-time feedback between precision mount model and axis mounted encoders; use of monolithic construction whenever appropriate for sustainable mechanical integrity; accelerating dome motion to eliminate repetitive shock; ducting internal telescope air to outside dome; and the principal design criteria: maximizing elastic repeatability while minimizing slack, plastic deformation and hysteresis to facilitate long-term repeatably precise pointing and tracking performance.
Submillihertz magnetic spectroscopy performed with a nanoscale quantum sensor
NASA Astrophysics Data System (ADS)
Schmitt, Simon; Gefen, Tuvia; Stürner, Felix M.; Unden, Thomas; Wolff, Gerhard; Müller, Christoph; Scheuer, Jochen; Naydenov, Boris; Markham, Matthew; Pezzagna, Sebastien; Meijer, Jan; Schwarz, Ilai; Plenio, Martin; Retzker, Alex; McGuinness, Liam P.; Jelezko, Fedor
2017-05-01
Precise timekeeping is critical to metrology, forming the basis by which standards of time, length, and fundamental constants are determined. Stable clocks are particularly valuable in spectroscopy because they define the ultimate frequency precision that can be reached. In quantum metrology, the qubit coherence time defines the clock stability, from which the spectral linewidth and frequency precision are determined. We demonstrate a quantum sensing protocol in which the spectral precision goes beyond the sensor coherence time and is limited by the stability of a classical clock. Using this technique, we observed a precision in frequency estimation scaling in time T as T-3/2 for classical oscillating fields. The narrow linewidth magnetometer based on single spins in diamond is used to sense nanoscale magnetic fields with an intrinsic frequency resolution of 607 microhertz, which is eight orders of magnitude narrower than the qubit coherence time.
Intraoperative irradiation: precision medicine for quality cancer control promotion.
Calvo, Felipe A
2017-02-02
Intraoperative irradiation was implemented 4 decades ago, pioneering the efforts to improve precision in local cancer therapy by combining real-time surgical exploration/resection with high single dose radiotherapy (Gunderson et al., Intraoperative irradiation: techniques and results, 2011). Clinical and technical developments have led to very precise radiation dose deposit. The ability to deliver a very precise dose of radiation is an essential element of contemporary multidisciplinary individualized oncology.This issue of Radiation Oncology contains a collection of expert review articles and updates with relevant data regarding intraoperative radiotherapy. Technology, physics, biology of single dose and clinical results in a variety of cancer sites and histologies are described and analyzed. The state of the art for advanced cancer care through medical innovation opens a significant opportunity for individualize cancer management across a broad spectrum of clinical practice. The advantage for tailoring diagnostic and treatment decisions in an individualized fashion will translate into precise medical treatment.
High-Precision Half-Life and Branching Ratio Measurements for the Superallowed β+ Emitter 26Alm
NASA Astrophysics Data System (ADS)
Finlay, P.; Svensson, C. E.; Demand, G. A.; Garrett, P. E.; Green, K. L.; Leach, K. G.; Phillips, A. A.; Rand, E. T.; Ball, G.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Sumithrarachchi, C. S.; Williams, S. J.; Triambak, S.
2013-03-01
High-precision half-life and branching-ratio measurements for the superallowed β+ emitter 26Alm were performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ≤ 15 ppm at 90% C.L. was determined for the sum of all possible non-analogue β+/EC decay branches of 26Alm, yielding a superallowed branching ratio of 100.0000+0-0.0015%. A value of T1/2 = 6:34654(76) s was determined for the 26Alm half-life which is consistent with, but 2.5 times more precise than, the previous world average. Combining these results with world-average measurements yields an ft value of 3037.58(60) s, the most precisely determined for any superallowed emitting nucleus to date. This high-precision ft value for 26Alm provides a new benchmark to refine theoretical models of isospin-symmetry-breaking effects in superallowed β decays.
Double-trap measurement of the proton magnetic moment at 0.3 parts per billion precision.
Schneider, Georg; Mooser, Andreas; Bohman, Matthew; Schön, Natalie; Harrington, James; Higuchi, Takashi; Nagahama, Hiroki; Sellner, Stefan; Smorra, Christian; Blaum, Klaus; Matsuda, Yasuyuki; Quint, Wolfgang; Walz, Jochen; Ulmer, Stefan
2017-11-24
Precise knowledge of the fundamental properties of the proton is essential for our understanding of atomic structure as well as for precise tests of fundamental symmetries. We report on a direct high-precision measurement of the magnetic moment μ p of the proton in units of the nuclear magneton μ N The result, μ p = 2.79284734462 (±0.00000000082) μ N , has a fractional precision of 0.3 parts per billion, improves the previous best measurement by a factor of 11, and is consistent with the currently accepted value. This was achieved with the use of an optimized double-Penning trap technique. Provided a similar measurement of the antiproton magnetic moment can be performed, this result will enable a test of the fundamental symmetry between matter and antimatter in the baryonic sector at the 10 -10 level. Copyright © 2017, American Association for the Advancement of Science.
Analysis of de-noising methods to improve the precision of the ILSF BPM electronic readout system
NASA Astrophysics Data System (ADS)
Shafiee, M.; Feghhi, S. A. H.; Rahighi, J.
2016-12-01
In order to have optimum operation and precise control system at particle accelerators, it is required to measure the beam position with the precision of sub-μm. We developed a BPM electronic readout system at Iranian Light Source Facility and it has been experimentally tested at ALBA accelerator facility. The results show the precision of 0.54 μm in beam position measurements. To improve the precision of this beam position monitoring system to sub-μm level, we have studied different de-noising methods such as principal component analysis, wavelet transforms, filtering by FIR, and direct averaging method. An evaluation of the noise reduction was given to testify the ability of these methods. The results show that the noise reduction based on Daubechies wavelet transform is better than other algorithms, and the method is suitable for signal noise reduction in beam position monitoring system.
Williams, Marc S; Buchanan, Adam H; Davis, F Daniel; Faucett, W Andrew; Hallquist, Miranda L G; Leader, Joseph B; Martin, Christa L; McCormick, Cara Z; Meyer, Michelle N; Murray, Michael F; Rahm, Alanna K; Schwartz, Marci L B; Sturm, Amy C; Wagner, Jennifer K; Williams, Janet L; Willard, Huntington F; Ledbetter, David H
2018-05-01
Health care delivery is increasingly influenced by the emerging concepts of precision health and the learning health care system. Although not synonymous with precision health, genomics is a key enabler of individualized care. Delivering patient-centered, genomics-informed care based on individual-level data in the current national landscape of health care delivery is a daunting challenge. Problems to overcome include data generation, analysis, storage, and transfer; knowledge management and representation for patients and providers at the point of care; process management; and outcomes definition, collection, and analysis. Development, testing, and implementation of a genomics-informed program requires multidisciplinary collaboration and building the concepts of precision health into a multilevel implementation framework. Using the principles of a learning health care system provides a promising solution. This article describes the implementation of population-based genomic medicine in an integrated learning health care system-a working example of a precision health program.
In praise of vagueness: malleability of vague information as a performance booster.
Mishra, Himanshu; Mishra, Arul; Shiv, Baba
2011-06-01
Is the eternal quest for precise information always worthwhile? Our research suggests that, at times, vagueness has its merits. Previous research has demonstrated that people prefer precise information over vague information because it gives them a sense of security and makes their environments more predictable. However, we show that the fuzzy boundaries afforded by vague information can actually help individuals perform better than can precise information. We document these findings across two laboratory studies and one quasi-field study that involved different performance-related contexts (mental acuity, physical strength, and weight loss). We argue that the malleability of vague information allows people to interpret it in the manner they desire, so that they can generate positive response expectancies and, thereby, perform better. The rigidity of precise information discourages desirable interpretations. Hence, on certain occasions, precise information is not as helpful as vague information in boosting performance.
Validating precision estimates in horizontal wind measurements from a Doppler lidar
Newsom, Rob K.; Brewer, W. Alan; Wilczak, James M.; ...
2017-03-30
Results from a recent field campaign are used to assess the accuracy of wind speed and direction precision estimates produced by a Doppler lidar wind retrieval algorithm. The algorithm, which is based on the traditional velocity-azimuth-display (VAD) technique, estimates the wind speed and direction measurement precision using standard error propagation techniques, assuming the input data (i.e., radial velocities) to be contaminated by random, zero-mean, errors. For this study, the lidar was configured to execute an 8-beam plan-position-indicator (PPI) scan once every 12 min during the 6-week deployment period. Several wind retrieval trials were conducted using different schemes for estimating themore » precision in the radial velocity measurements. Here, the resulting wind speed and direction precision estimates were compared to differences in wind speed and direction between the VAD algorithm and sonic anemometer measurements taken on a nearby 300 m tower.« less
An Improved Method of AGM for High Precision Geolocation of SAR Images
NASA Astrophysics Data System (ADS)
Zhou, G.; He, C.; Yue, T.; Huang, W.; Huang, Y.; Li, X.; Chen, Y.
2018-05-01
In order to take full advantage of SAR images, it is necessary to obtain the high precision location of the image. During the geometric correction process of images, to ensure the accuracy of image geometric correction and extract the effective mapping information from the images, precise image geolocation is important. This paper presents an improved analytical geolocation method (IAGM) that determine the high precision geolocation of each pixel in a digital SAR image. This method is based on analytical geolocation method (AGM) proposed by X. K. Yuan aiming at realizing the solution of RD model. Tests will be conducted using RADARSAT-2 SAR image. Comparing the predicted feature geolocation with the position as determined by high precision orthophoto, results indicate an accuracy of 50m is attainable with this method. Error sources will be analyzed and some recommendations about improving image location accuracy in future spaceborne SAR's will be given.
Precision Therapy for Lung Cancer: Tyrosine Kinase Inhibitors and Beyond.
Rajan, Arun; Schrump, David S
2015-01-01
For patients with advanced cancers there has been a concerted effort to transition from a generic treatment paradigm to one based on tumor-specific biologic, and patient-specific clinical characteristics. This approach, known as precision therapy has been made possible owing to widespread availability and a reduction in the cost of cutting-edge technologies that are used to study the genomic, proteomic, and metabolic attributes of individual tumors. This review traces the evolution of precision therapy for lung cancer from the identification of molecular subsets of the disease to the development and approval of tyrosine kinase, as well as immune checkpoint inhibitors for lung cancer therapy. Challenges of the precision therapy era including the emergence of acquired resistance, identification of untargetable mutations, and the effect on clinical trial design are discussed. We conclude by highlighting newer applications for the concept of precision therapy. Published by Elsevier Inc.
Temporally precise single-cell resolution optogenetics
Shemesh, Or A.; Tanese, Dimitrii; Zampini, Valeria; Linghu, Changyang; Piatkevich, Kiryl; Ronzitti, Emiliano; Papagiakoumou, Eirini; Boyden, Edward S.; Emiliani, Valentina
2017-01-01
Optogenetic control of individual neurons with high temporal precision, within intact mammalian brain circuitry, would enable powerful explorations of how neural circuits operate. Two-photon computer generated holography enables precise sculpting of light, and could in principle enable simultaneous illumination of many neurons in a network, with the requisite temporal precision to simulate accurate neural codes. We designed a high efficacy soma-targeted opsin, finding that fusing the N-terminal 150 residues of kainate receptor subunit 2 (KA2) to the recently discovered high-photocurrent channelrhodopsin CoChR restricted expression of this opsin primarily to the cell body of mammalian cortical neurons. In combination with two-photon holographic stimulation, we found that this somatic CoChR (soCoChR) enabled photostimulation of individual cells in intact cortical circuits with single cell resolution and <1 millisecond temporal precision, and use soCoChR to perform connectivity mapping on intact cortical circuits. PMID:29184208
Strategies For Clinical Implementation: Precision Oncology At Three Distinct Institutions.
Nadauld, Lincoln D; Ford, James M; Pritchard, Daryl; Brown, Thomas
2018-05-01
Despite rapid advances in molecular diagnostics and targeted therapeutics, the adoption of precision medicine into clinical oncology workflows has been slow. Questions about clinical utility, inconsistent reimbursement for molecular diagnostics, and limited access to targeted therapies are some of the major hurdles that have hampered clinical adoption. Despite these challenges, providers have invested in precision medicine programs in an ongoing search for innovative care models to deliver improved patient outcomes and achieve economic gains. We describe the precision oncology medicine programs implemented by an integrated delivery system, a community care center, and an academic medical center, to demonstrate the approaches and challenges associated with clinical implementation efforts designed to advance this treatment paradigm. Payer policies that include coverage for broad genomic testing panels would support the broader application of precision medicine, deepen research benefits, and bring targeted therapies to more patients with advanced cancer.
Precision controllability of the F-15 airplane
NASA Technical Reports Server (NTRS)
Sisk, T. R.; Matheny, N. W.
1979-01-01
A flying qualities evaluation conducted on a preproduction F-15 airplane permitted an assessment to be made of its precision controllability in the high subsonic and low transonic flight regime over the allowable angle of attack range. Precision controllability, or gunsight tracking, studies were conducted in windup turn maneuvers with the gunsight in the caged pipper mode and depressed 70 mils. This evaluation showed the F-15 airplane to experience severe buffet and mild-to-moderate wing rock at the higher angles of attack. It showed the F-15 airplane radial tracking precision to vary from approximately 6 to 20 mils over the load factor range tested. Tracking in the presence of wing rock essentially doubled the radial tracking error generated at the lower angles of attack. The stability augmentation system affected the tracking precision of the F-15 airplane more than it did that of previous aircraft studied.
Lerchenmueller, Marc J.; Sorenson, Olav
2016-01-01
We examined the usefulness (precision) and completeness (recall) of the Author-ity author disambiguation for PubMed articles by associating articles with scientists funded by the National Institutes of Health (NIH). In doing so, we exploited established unique identifiers—Principal Investigator (PI) IDs—that the NIH assigns to funded scientists. Analyzing a set of 36,987 NIH scientists who received their first R01 grant between 1985 and 2009, we identified 355,921 articles appearing in PubMed that would allow us to evaluate the precision and recall of the Author-ity disambiguation. We found that Author-ity identified the NIH scientists with 99.51% precision across the articles. It had a corresponding recall of 99.64%. Precision and recall, moreover, appeared stable across common and uncommon last names, across ethnic backgrounds, and across levels of scientist productivity. PMID:27367860
Lerchenmueller, Marc J; Sorenson, Olav
2016-01-01
We examined the usefulness (precision) and completeness (recall) of the Author-ity author disambiguation for PubMed articles by associating articles with scientists funded by the National Institutes of Health (NIH). In doing so, we exploited established unique identifiers-Principal Investigator (PI) IDs-that the NIH assigns to funded scientists. Analyzing a set of 36,987 NIH scientists who received their first R01 grant between 1985 and 2009, we identified 355,921 articles appearing in PubMed that would allow us to evaluate the precision and recall of the Author-ity disambiguation. We found that Author-ity identified the NIH scientists with 99.51% precision across the articles. It had a corresponding recall of 99.64%. Precision and recall, moreover, appeared stable across common and uncommon last names, across ethnic backgrounds, and across levels of scientist productivity.
Tarone, Aaron M; Foran, David R
2011-01-01
Forensic entomologists use size and developmental stage to estimate blow fly age, and from those, a postmortem interval. Since such estimates are generally accurate but often lack precision, particularly in the older developmental stages, alternative aging methods would be advantageous. Presented here is a means of incorporating developmentally regulated gene expression levels into traditional stage and size data, with a goal of more precisely estimating developmental age of immature Lucilia sericata. Generalized additive models of development showed improved statistical support compared to models that did not include gene expression data, resulting in an increase in estimate precision, especially for postfeeding third instars and pupae. The models were then used to make blind estimates of development for 86 immature L. sericata raised on rat carcasses. Overall, inclusion of gene expression data resulted in increased precision in aging blow flies. © 2010 American Academy of Forensic Sciences.
Precision control of multiple quantum cascade lasers for calibration systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taubman, Matthew S., E-mail: Matthew.Taubman@pnnl.gov; Myers, Tanya L.; Pratt, Richard M.
We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby,more » and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.« less
Slater, Jim; Shields, Laura; Racette, Ray J; Juzwishin, Donald; Coppes, Max
2015-11-01
In the era of personalized and precision medicine, the approach to healthcare is quickly changing. Genetic and other molecular information are being increasingly demanded by clinicians and expected by patients for prevention, screening, diagnosis, prognosis, health promotion, and treatment of an increasing number of conditions. As a result of these developments, Canadian health leaders must understand and be prepared to lead the necessary changes associated with these disruptive technologies. This article focuses on precision therapeutics but also provides background on the concepts and terminology related to personalized and precision medicine and explores Canadian health leadership and system issues that may pose barriers to their implementation. The article is intended to inspire, educate, and mobilize Canadian health leaders to initiate dialogue around the transformative changes necessary to ready the healthcare system to realize the benefits of precision therapeutics. © 2015 Collège canadien des leaders en santé
NASA Astrophysics Data System (ADS)
Perry, Adam J.; Hodges, James N.; Markus, Charles R.; Kocheril, G. Stephen; McCall, Benjamin J.
2015-11-01
The H3+ molecular ion has served as a long-standing benchmark for state-of-the-art ab initio calculations of molecular potentials and variational calculations of rovibrational energy levels. However, the accuracy of such calculations would not have been confirmed if not for the wealth of spectroscopic data that has been made available for this molecule. Recently, a new high-precision ion spectroscopy technique was demonstrated by Hodges et al., which led to the first highly accurate and precise (∼MHz) H3+ transition frequencies. As an extension of this work, we present ten additional R-branch transitions measured to similar precision as a next step toward the ultimate goal of producing a comprehensive high-precision survey of this molecule, from which rovibrational energy levels can be calculated.
Fixed precision sampling plans for white apple leafhopper (Homoptera: Cicadellidae) on apple.
Beers, Elizabeth H; Jones, Vincent P
2004-10-01
Constant precision sampling plans for the white apple leafhopper, Typhlocyba pomaria McAtee, were developed so that it could be used as an indicator species for system stability as new integrated pest management programs without broad-spectrum pesticides are developed. Taylor's power law was used to model the relationship between the mean and the variance, and Green's constant precision sequential sample equation was used to develop sampling plans. Bootstrap simulations of the sampling plans showed greater precision (D = 0.25) than the desired precision (Do = 0.3), particularly at low mean population densities. We found that by adjusting the Do value in Green's equation to 0.4, we were able to reduce the average sample number by 25% and provided an average D = 0.31. The sampling plan described allows T. pomaria to be used as reasonable indicator species of agroecosystem stability in Washington apple orchards.
Precision digital control systems
NASA Astrophysics Data System (ADS)
Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.
This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.
A Concept for Airborne Precision Spacing for Dependent Parallel Approaches
NASA Technical Reports Server (NTRS)
Barmore, Bryan E.; Baxley, Brian T.; Abbott, Terence S.; Capron, William R.; Smith, Colin L.; Shay, Richard F.; Hubbs, Clay
2012-01-01
The Airborne Precision Spacing concept of operations has been previously developed to support the precise delivery of aircraft landing successively on the same runway. The high-precision and consistent delivery of inter-aircraft spacing allows for increased runway throughput and the use of energy-efficient arrivals routes such as Continuous Descent Arrivals and Optimized Profile Descents. This paper describes an extension to the Airborne Precision Spacing concept to enable dependent parallel approach operations where the spacing aircraft must manage their in-trail spacing from a leading aircraft on approach to the same runway and spacing from an aircraft on approach to a parallel runway. Functionality for supporting automation is discussed as well as procedures for pilots and controllers. An analysis is performed to identify the required information and a new ADS-B report is proposed to support these information needs. Finally, several scenarios are described in detail.
The forthcoming era of precision medicine.
Gamulin, Stjepan
2016-11-01
The aim of this essay is to present the definition and principles of personalized or precision medicine, the perspective and barriers to its development and clinical application. The implementation of precision medicine in health care requires the coordinated efforts of all health care stakeholders (the biomedical community, government, regulatory bodies, patients' groups). Particularly, translational research with the integration of genomic and comprehensive data from all levels of the organism ("big data"), development of bioinformatics platforms enabling network analysis of disease etiopathogenesis, development of a legislative framework for handling personal data, and new paradigms of medical education are necessary for successful application of the concept of precision medicine in health care. In the present and future era of precision medicine, the collaboration of all participants in health care is necessary for its realization, resulting in improvement of diagnosis, prevention and therapy, based on a holistic, individually tailored approach. Copyright © 2016 by Academy of Sciences and Arts of Bosnia and Herzegovina.
Ethical considerations of neuro-oncology trial design in the era of precision medicine.
Gupta, Saksham; Smith, Timothy R; Broekman, Marike L
2017-08-01
The field of oncology is currently undergoing a paradigm shift. Advances in the understanding of tumor biology and in tumor sequencing technology have contributed to the shift towards precision medicine, the therapeutic framework of targeting the individual oncogenic changes each tumor harbors. The success of precision medicine therapies, such as targeted kinase inhibitors and immunotherapies, in other cancers have motivated studies in brain cancers. The high specificity and cost of these therapies also encourage a shift in clinical trial design away from randomized control trials towards smaller, more exclusive early phase clinical trials. While these new trials advance the clinical application of increasingly precise and individualized therapies, their design brings ethical challenges . We review the pertinent ethical considerations for clinical trials of precision medicine in neuro-oncology and discuss methods to protect patients in this new era of trial design.
High-Precision Half-Life Measurement for the Superallowed {beta}{sup +} Emitter {sup 26}Al{sup m}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finlay, P.; Svensson, C. E.; Green, K. L.
2011-01-21
A high-precision half-life measurement for the superallowed {beta}{sup +} emitter {sup 26}Al{sup m} was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T{sub 1/2}=6346.54{+-}0.46{sub stat{+-}}0.60{sub syst} ms, consistent with, but 2.5 times more precise than, the previous world average. The {sup 26}Al{sup m} half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed {beta} decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for {sup 26}Al{sup m}, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi {beta}-decay studies used to test the conserved vector current hypothesismore » and determine the V{sub ud} element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.« less
Low-Frequency Oscillations and Control of the Motor Output
Lodha, Neha; Christou, Evangelos A.
2017-01-01
A less precise force output impairs our ability to perform movements, learn new motor tasks, and use tools. Here we show that low-frequency oscillations in force are detrimental to force precision. We summarize the recent evidence that low-frequency oscillations in force output represent oscillations of the spinal motor neuron pool from the voluntary drive, and can be modulated by shifting power to higher frequencies. Further, force oscillations below 0.5 Hz impair force precision with increased voluntary drive, aging, and neurological disease. We argue that the low-frequency oscillations are (1) embedded in the descending drive as shown by the activation of multiple spinal motor neurons, (2) are altered with force intensity and brain pathology, and (3) can be modulated by visual feedback and motor training to enhance force precision. Thus, low-frequency oscillations in force provide insight into how the human brain regulates force precision. PMID:28261107
Sovereignty and Collaboration: Affordable Strategies in Times of Austerity
2016-10-01
provide precision-guided bombs and a land-support SOVEREIGNTY—ANALYSIS 26 vehicle were delivered for more than 20 percent below the expenditure ini...weapon Precision-guided bomb Support vehicle Panther command & control vehicle Successor Identification Friend or Foe (IFF) Joint combat aircraft...GLMRS) Multi-role armoured vehicle (MRAV) Next-generation light anti-armoured weapon Precision-guided bomb Support vehicle Panther command & control
Scheduling Mission-Critical Flows in Congested and Contested Airborne Network Environments
2018-03-01
precision agriculture [64–71]. However, designing, implementing, and testing UAV networks poses numerous interdisciplinary challenges because the...applications including search and rescue, disaster relief, precision agriculture , environmental monitoring, and surveillance. Many of these applications...monitoring enabling precision agriculture ,” in Automation Science and Engineering (CASE), 2015 IEEE International Conference on. IEEE, 2015, pp. 462–469. [65
Test of CCD Precision Limits for Differential Photometry
NASA Technical Reports Server (NTRS)
Borucki, W. J.; Dunham, E. W.; Wei, M. Z.; Robinson, L. B.; Ford, C. H.; Granados, A. F.
1995-01-01
Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 105. Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.
Precision blackbody sources for radiometric standards.
Sapritsky, V I; Khlevnoy, B B; Khromchenko, V B; Lisiansky, B E; Mekhontsev, S N; Melenevsky, U A; Morozova, S P; Prokhorov, A V; Samoilov, L N; Shapoval, V I; Sudarev, K A; Zelener, M F
1997-08-01
The precision blackbody sources developed at the All-Russian Institute for Optical and Physical Measurements (Moscow, Russia) and their characteristics are analyzed. The precision high-temperature graphite blackbody BB22p, large-area high-temperature pyrolytic graphite blackbody BB3200pg, middle-temperature graphite blackbody BB2000, low-temperature blackbody BB300, and gallium fixed-point blackbody BB29gl and their characteristics are described.
1987-02-06
precisely the less favorable variant preventing extrication from foreign indebtedness. In addition to the trend toward stagnation of growth rate...another alarming economic indicator is precisely the decline in export capabilities on the sector most important to us, namely, in the sales of Polish...market economy, become a huge exporter with a tremendous competitive strength precisely on the markets on which we still have something to say. And
Precision Engineering - SRO 154.
1986-01-01
Operation The principle of interferometric displacement measurement devices is that if two identical, coherent, monochromatic light beams are directed...laser interferometric feedback to enhance the accuracy and precision of a lead screw stage. The precision translation stage was designed to produce...and the deepest was 22 micrometers (875 microinches). Figures 5, 6 and 7 are Nomarsky photomicrographs showing the begin- ning, middle and end of a
Precision and Fast Wavelength Tuning of a Dynamically Phase-Locked Widely-Tunable Laser
NASA Technical Reports Server (NTRS)
Numata, Kenji; Chen, Jeffrey R.; Wu, Stewart T.
2012-01-01
We report a precision and fast wavelength tuning technique demonstrated for a digital-supermode distributed Bragg reflector laser. The laser was dynamically offset-locked to a frequency-stabilized master laser using an optical phase-locked loop, enabling precision fast tuning to and from any frequencies within a 40-GHz tuning range. The offset frequency noise was suppressed to the statically offset-locked level in less than 40 s upon each frequency switch, allowing the laser to retain the absolute frequency stability of the master laser. This technique satisfies stringent requirements for gas sensing lidars and enables other applications that require such well-controlled precision fast tuning.
Precision Farming and Precision Pest Management: The Power of New Crop Production Technologies
Strickland, R. Mack; Ess, Daniel R.; Parsons, Samuel D.
1998-01-01
The use of new technologies including Geographic Information Systems (GIS), the Global Positioning System (GPS), Variable Rate Technology (VRT), and Remote Sensing (RS) is gaining acceptance in the present high-technology, precision agricultural industry. GIS provides the ability to link multiple data values for the same geo-referenced location, and provides the user with a graphical visualization of such data. When GIS is coupled with GPS and RS, management decisions can be applied in a more precise "micro-managed" manner by using VRT techniques. Such technology holds the potential to reduce agricultural crop production costs as well as crop and environmental damage. PMID:19274236
Measurement of whole tire profile
NASA Astrophysics Data System (ADS)
Yang, Yongyue; Jiao, Wenguang
2010-08-01
In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.
High precision localization of intracerebral hemorrhage based on 3D MPR on head CT images
NASA Astrophysics Data System (ADS)
Sun, Jianyong; Hou, Xiaoshuai; Sun, Shujie; Zhang, Jianguo
2017-03-01
The key step for minimally invasive intracerebral hemorrhage surgery is precisely positioning the hematoma location in the brain before and during the hematoma surgery, which can significantly improves the success rate of puncture hematoma. We designed a 3D computerized surgical plan (CSP) workstation precisely to locate brain hematoma based on Multi-Planar Reconstruction (MPR) visualization technique. We used ten patients' CT/MR studies to verify our designed CSP intracerebral hemorrhage localization method. With the doctor's assessment and comparing with the results of manual measurements, the output of CSP WS for hematoma surgery is more precise and reliable than manual procedure.
Mechanism Design Principle for Optical-Precision, Deployable Instruments
NASA Technical Reports Server (NTRS)
Lake, Mark S.; Hachkowski, M. Roman
2000-01-01
The present paper is intended to be a guide for the design of 'microdynamically quiet' deployment mechanisms for optical-precision structures, such as deployable telescope mirrors and optical benches. Many of the guidelines included herein come directly from the field of optomechanical engineering, and are neither newly developed guidelines nor are they uniquely applicable to high-precision deployment mechanisms. However, the application of these guidelines to the design of deployment mechanisms is a rather new practice, so efforts are made herein to illustrate the process through the discussion of specific examples. The present paper summarizes a more extensive set of design guidelines for optical-precision mechanisms that are under development.
NASA Technical Reports Server (NTRS)
1975-01-01
The Proceedings contain the papers presented at the Seventh Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting and the edited record of the discussion period following each paper. This meeting provided a forum to promote more effective, efficient, economical and skillful applications of PTTI technology to the many problem areas to which PTTI offers solutions. Specifically the purpose of the meeting is to: disseminate, coordinate, and exchange practical information associated with precise time and frequency; acquaint systems engineers, technicians and managers with precise time and frequency technology and its applications; and review present and future requirements for PTTI.
Achieving High Resolution Timer Events in Virtualized Environment.
Adamczyk, Blazej; Chydzinski, Andrzej
2015-01-01
Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.
Kinematic precision of gear trains
NASA Technical Reports Server (NTRS)
Litvin, F. L.; Goldrich, R. N.; Coy, J. J.; Zaretsky, E. V.
1982-01-01
Kinematic precision is affected by errors which are the result of either intentional adjustments or accidental defects in manufacturing and assembly of gear trains. A method for the determination of kinematic precision of gear trains is described. The method is based on the exact kinematic relations for the contact point motions of the gear tooth surfaces under the influence of errors. An approximate method is also explained. Example applications of the general approximate methods are demonstrated for gear trains consisting of involute (spur and helical) gears, circular arc (Wildhaber-Novikov) gears, and spiral bevel gears. Gear noise measurements from a helicopter transmission are presented and discussed with relation to the kinematic precision theory.
NASA Astrophysics Data System (ADS)
Furlong, Cosme; Yokum, Jeffrey S.; Pryputniewicz, Ryszard J.
2002-06-01
Sensitivity, accuracy, and precision characteristics in quantitative optical metrology techniques, and specifically in optoelectronic holography based on fiber optics and high-spatial and high-digital resolution cameras, are discussed in this paper. It is shown that sensitivity, accuracy, and precision dependent on both, the effective determination of optical phase and the effective characterization of the illumination-observation conditions. Sensitivity, accuracy, and precision are investigated with the aid of National Institute of Standards and Technology (NIST) traceable gages, demonstrating the applicability of quantitative optical metrology techniques to satisfy constantly increasing needs for the study and development of emerging technologies.
A portable device for calibration of autocollimators with nanoradian precision
NASA Astrophysics Data System (ADS)
Yandayan, Tanfer
2017-09-01
A portable device has been developed in TUBITAK UME to calibrate high precision autocollimators with nanoradian precision. The device can operate in the range of +/-4500" which is far enough for the calibration of the available autocollimators and can generate ultra-small angles in measurement steps of 0.0005" (2.5 nrad). Description of the device with the performance tests using the calibrated precise autocollimators and novel methods will be reported. The test results indicate that the device is a good candidate for application to on-site/in-situ calibration of autocollimators with expanded uncertainties of 0.01" (50 nrad) particularly those used in slope measuring profilers.
Light leptonic new physics at the precision frontier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Dall, Matthias, E-mail: mledall@uvic.ca
2016-06-21
Precision probes of new physics are often interpreted through their indirect sensitivity to short-distance scales. In this proceedings contribution, we focus on the question of which precision observables, at current sensitivity levels, allow for an interpretation via either short-distance new physics or consistent models of long-distance new physics, weakly coupled to the Standard Model. The electroweak scale is chosen to set the dividing line between these scenarios. In particular, we find that inverse see-saw models of neutrino mass allow for light new physics interpretations of most precision leptonic observables, such as lepton universality, lepton flavor violation, but not for themore » electron EDM.« less
Precision Medicine Approaches to Diabetic Kidney Disease: Tissue as an Issue.
Gluck, Caroline; Ko, Yi-An; Susztak, Katalin
2017-05-01
Precision medicine approaches, that tailor medications to specific individuals has made paradigm-shifting improvements for patients with certain cancer types. Such approaches, however, have not been implemented for patients with diabetic kidney disease. Precision medicine could offer new avenues for novel diagnostic, prognostic and targeted therapeutics development. Genetic studies associated with multiscalar omics datasets from tissue and cell types of interest of well-characterized cohorts are needed to change the current paradigm. In this review, we will discuss precision medicine approaches that the nephrology community can take to analyze tissue samples to develop new therapeutics for patients with diabetic kidney disease.
[Precision medicine : a required approach for the general internist].
Waeber, Gérard; Cornuz, Jacques; Gaspoz, Jean-Michel; Guessous, Idris; Mooser, Vincent; Perrier, Arnaud; Simonet, Martine Louis
2017-01-18
The general internist cannot be a passive bystander of the anticipated medical revolution induced by precision medicine. This latter aims to improve the predictive and/or clinical course of an individual by integrating all biological, genetic, environmental, phenotypic and psychosocial knowledge of a person. In this article, national and international initiatives in the field of precision medicine are discussed as well as the potential financial, ethical and limitations of personalized medicine. The question is not to know if precision medicine will be part of everyday life but rather to integrate early the general internist in multidisciplinary teams to ensure optimal information and shared-decision process with patients and individuals.
High-precision multiband spectroscopy of ultracold fermions in a nonseparable optical lattice
NASA Astrophysics Data System (ADS)
Fläschner, Nick; Tarnowski, Matthias; Rem, Benno S.; Vogel, Dominik; Sengstock, Klaus; Weitenberg, Christof
2018-05-01
Spectroscopic tools are fundamental for the understanding of complex quantum systems. Here, we demonstrate high-precision multiband spectroscopy in a graphenelike lattice using ultracold fermionic atoms. From the measured band structure, we characterize the underlying lattice potential with a relative error of 1.2 ×10-3 . Such a precise characterization of complex lattice potentials is an important step towards precision measurements of quantum many-body systems. Furthermore, we explain the excitation strengths into different bands with a model and experimentally study their dependency on the symmetry of the perturbation operator. This insight suggests the excitation strengths as a suitable observable for interaction effects on the eigenstates.
Integrated titer plate-injector head for microdrop array preparation, storage and transfer
Swierkowski, Stefan P.
2000-01-01
An integrated titer plate-injector head for preparing and storing two-dimensional (2-D) arrays of microdrops and for ejecting part or all of the microdrops and inserting same precisely into 2-D arrays of deposition sites with micrometer precision. The titer plate-injector head includes integrated precision formed nozzles with appropriate hydrophobic surface features and evaporative constraints. A reusable pressure head with a pressure equalizing feature is added to the titer plate to perform simultaneous precision sample ejection. The titer plate-injector head may be utilized in various applications including capillary electrophoresis, chemical flow injection analysis, microsample array preparation, etc.
A comparison of Boolean-based retrieval to the WAIS system for retrieval of aeronautical information
NASA Technical Reports Server (NTRS)
Marchionini, Gary; Barlow, Diane
1994-01-01
An evaluation of an information retrieval system using a Boolean-based retrieval engine and inverted file architecture and WAIS, which uses a vector-based engine, was conducted. Four research questions in aeronautical engineering were used to retrieve sets of citations from the NASA Aerospace Database which was mounted on a WAIS server and available through Dialog File 108 which served as the Boolean-based system (BBS). High recall and high precision searches were done in the BBS and terse and verbose queries were used in the WAIS condition. Precision values for the WAIS searches were consistently above the precision values for high recall BBS searches and consistently below the precision values for high precision BBS searches. Terse WAIS queries gave somewhat better precision performance than verbose WAIS queries. In every case, a small number of relevant documents retrieved by one system were not retrieved by the other, indicating the incomplete nature of the results from either retrieval system. Relevant documents in the WAIS searches were found to be randomly distributed in the retrieved sets rather than distributed by ranks. Advantages and limitations of both types of systems are discussed.
Capacity and precision in an animal model of visual short-term memory.
Lara, Antonio H; Wallis, Jonathan D
2012-03-14
Temporary storage of information in visual short-term memory (VSTM) is a key component of many complex cognitive abilities. However, it is highly limited in capacity. Understanding the neurophysiological nature of this capacity limit will require a valid animal model of VSTM. We used a multiple-item color change detection task to measure macaque monkeys' VSTM capacity. Subjects' performance deteriorated and reaction times increased as a function of the number of items in memory. Additionally, we measured the precision of the memory representations by varying the distance between sample and test colors. In trials with similar sample and test colors, subjects made more errors compared to trials with highly discriminable colors. We modeled the error distribution as a Gaussian function and used this to estimate the precision of VSTM representations. We found that as the number of items in memory increases the precision of the representations decreases dramatically. Additionally, we found that focusing attention on one of the objects increases the precision with which that object is stored and degrades the precision of the remaining. These results are in line with recent findings in human psychophysics and provide a solid foundation for understanding the neurophysiological nature of the capacity limit of VSTM.
Morgan, Gilberto; Aftimos, Philippe; Awada, Ahmad
2016-09-01
Precision oncology has been a strategy of prevention, screening, and treatment. Although much has been invested, have the results fallen so far short of the promise? The advancement of technology and research has opened new doors, yet a variety of pitfalls are present. This review presents the successes, failures, and opportunities of precision oncology in the current landscape. The use of targeted gene sequencing and the overwhelming results of superresponders have generated much excitement and support for precision oncology from the medical community. Despite notable successes, many challenges still pave the way of precision oncology: intratumoral heterogeneity, the need for serial biopsies, availability of treatments, target prioritization, ethical issues with germline incidental findings, medical education, clinical trial design, and costs. Precision oncology shows much potential through the use of next-generation sequencing and molecular advances, but does this potential warrant the investment? There are many obstacles on the way of this technology that should make us question if the investment (both monetary and man-hours) will live up to the promise. The review aims to not criticize this technology, but to give a realistic view of where we are, especially regarding cancer treatment and prevention.
NASA Astrophysics Data System (ADS)
Kasson, A.
2016-12-01
In January 2016, elementar Analysensysteme, GmbH (Germany), in conjunction with their daughter company, Isoprime Ltd. (United Kingdom) released the Precision isotope ratio mass spectrometer. The Precision is the newest light element IRMS on the market and adds some unique hardware and software functionalities to the basic core of stable isotopic research previously unseen. Although this system is designed to make the typical bulk and compound specific measurements that functioning stable isotope laboratories have been accustomed to, it has been designed to make complicated measurements of isotopologues, isotopomers and clumped isotopes much more turnkey and user friendly. Here we focus on some datasets that have been collected from three different beta test sites and highlight the functional use of the new hardware in conjunction with ionOS operating software. As part of those highlights, the improved precision, accuracy and ion optics of the Precision IRMS will be demonstrated. In addition, we intend to show that the reprocessing functions on the ionOS software package are not only beneficial to users of just the Precision IRMS, but to the entire stable isotope community as a whole.
Wang, Jinjing Jenny; Odic, Darko; Halberda, Justin; Feigenson, Lisa
2016-07-01
From early in life, humans have access to an approximate number system (ANS) that supports an intuitive sense of numerical quantity. Previous work in both children and adults suggests that individual differences in the precision of ANS representations correlate with symbolic math performance. However, this work has been almost entirely correlational in nature. Here we tested for a causal link between ANS precision and symbolic math performance by asking whether a temporary modulation of ANS precision changes symbolic math performance. First, we replicated a recent finding that 5-year-old children make more precise ANS discriminations when starting with easier trials and gradually progressing to harder ones, compared with the reverse. Next, we show that this brief modulation of ANS precision influenced children's performance on a subsequent symbolic math task but not a vocabulary task. In a supplemental experiment, we present evidence that children who performed ANS discriminations in a random trial order showed intermediate performance on both the ANS task and the symbolic math task, compared with children who made ordered discriminations. Thus, our results point to a specific causal link from the ANS to symbolic math performance. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Jinjing (Jenny); Odic, Darko; Halberda, Justin; Feigenson, Lisa
2016-01-01
From early in life, humans have access to an Approximate Number System (ANS) that supports an intuitive sense of numerical quantity. Previous work in both children and adults suggests that individual differences in the precision of ANS representations correlate with symbolic math performance. However, this work has been almost entirely correlational in nature. Here we tested for a causal link between ANS precision and symbolic math performance by asking whether a temporary modulation of ANS precision changes symbolic math performance. First we replicated a recent finding that 5-year-old children make more precise ANS discriminations when starting with easier trials and gradually progressing to harder ones, compared to the reverse. Next, we show that this brief modulation of ANS precision influenced children’s performance on a subsequent symbolic math task, but not a vocabulary task. In a supplemental experiment we present evidence that children who performed ANS discriminations in a random trial order showed intermediate performance both on the ANS task and the symbolic math task, compared to the children who made ordered discriminations. Thus, our results point to a specific causal link from the ANS to symbolic math performance. PMID:27061668
High precision measurement of the proton charge radius: The PRad experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meziane, Mehdi
2013-11-01
The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 {+-} 0.0007 fm was extracted which is 7{sigma} smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these "electronic" determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved atmore » Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup -4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.« less
Precise point positioning with the BeiDou navigation satellite system.
Li, Min; Qu, Lizhong; Zhao, Qile; Guo, Jing; Su, Xing; Li, Xiaotao
2014-01-08
By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS) around the World. The Position and Navigation Data Analyst (PANDA) software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP). The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems.
PRECISION MANAGEMENT OF LOCALIZED PROSTATE CANCER
VanderWeele, David J.; Turkbey, Baris; Sowalsky, Adam G.
2017-01-01
Introduction The vast majority of men who are diagnosed with prostate cancer die of other causes, highlighting the importance of determining which patient has a risk of death from prostate cancer. Precision management of prostate cancer patients includes distinguishing which men have potentially lethal disease and employing strategies for determining which treatment modality appropriately balances the desire to achieve a durable response while preventing unnecessary overtreatment. Areas covered In this review, we highlight precision approaches to risk assessment and a context for the precision-guided application of definitive therapy. We focus on three dilemmas relevant to the diagnosis of localized prostate cancer: screening, the decision to treat, and postoperative management. Expert commentary In the last five years, numerous precision tools have emerged with potential benefit to the patient. However, to achieve optimal outcome, the decision to employ one or more of these tests must be considered in the context of prevailing conventional factors. Moreover, performance and interpretation of a molecular or imaging precision test remains practitioner-dependent. The next five years will witness increased marriage of molecular and imaging biomarkers for improved multi-modal diagnosis and discrimination of disease that is aggressive versus truly indolent. PMID:28133630
Precise Point Positioning with the BeiDou Navigation Satellite System
Li, Min; Qu, Lizhong; Zhao, Qile; Guo, Jing; Su, Xing; Li, Xiaotao
2014-01-01
By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS) around the World. The Position and Navigation Data Analyst (PANDA) software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP). The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems. PMID:24406856
NASA Astrophysics Data System (ADS)
Luo, Hanjun; Ouyang, Zhengbiao; Liu, Qiang; Chen, Zhiliang; Lu, Hualan
2017-10-01
Cumulative pulses detection with appropriate cumulative pulses number and threshold has the ability to improve the detection performance of the pulsed laser ranging system with GM-APD. In this paper, based on Poisson statistics and multi-pulses cumulative process, the cumulative detection probabilities and their influence factors are investigated. With the normalized probability distribution of each time bin, the theoretical model of the range accuracy and precision is established, and the factors limiting the range accuracy and precision are discussed. The results show that the cumulative pulses detection can produce higher target detection probability and lower false alarm probability. However, for a heavy noise level and extremely weak echo intensity, the false alarm suppression performance of the cumulative pulses detection deteriorates quickly. The range accuracy and precision is another important parameter evaluating the detection performance, the echo intensity and pulse width are main influence factors on the range accuracy and precision, and higher range accuracy and precision is acquired with stronger echo intensity and narrower echo pulse width, for 5-ns echo pulse width, when the echo intensity is larger than 10, the range accuracy and precision lower than 7.5 cm can be achieved.
NASA Astrophysics Data System (ADS)
Amiri, N.; Bertiger, W. I.; Lu, W.; Miller, M. A.; David, M. W.; Ries, P.; Romans, L.; Sibois, A. E.; Sibthorpe, A.; Sakumura, C.
2017-12-01
Impact of Multi-GNSS Observations on Precise Orbit Determination and Precise Point Positioning Solutions Authors: Nikta Amiri, Willy Bertiger, Wenwen Lu, Mark Miller, David Murphy, Paul Ries, Larry Romans, Carly Sakumura, Aurore Sibois, Anthony Sibthorpe All at the Jet Propulsion Laboratory, California Institute of Technology Multiple Global Navigation Satellite Systems (GNSS) are now in various stages of completion. The four current constellations (GPS, GLONASS, BeiDou, Galileo) comprise more than 80 satellites as of July 2017, with 120 satellites expected to be available when all four constellations become fully operational. We investigate the impact of simultaneous observations to these four constellations on global network precise orbit determination (POD) solutions, and compare them to available sets of orbit and clock products submitted to the Multi-GNSS Experiment (MGEX). Using JPL's GipsyX software, we generate orbit and clock products for the four constellations. The resulting solutions are evaluated based on a number of metrics including day-to-day internal and external orbit and/or clock overlaps and estimated constellation biases. Additionally, we examine estimated station positions obtained from precise point positioning (PPP) solutions by comparing results generated from multi-GNSS and GPS-only orbit and clock products.
Measurement Model and Precision Analysis of Accelerometers for Maglev Vibration Isolation Platforms.
Wu, Qianqian; Yue, Honghao; Liu, Rongqiang; Zhang, Xiaoyou; Ding, Liang; Liang, Tian; Deng, Zongquan
2015-08-14
High precision measurement of acceleration levels is required to allow active control for vibration isolation platforms. It is necessary to propose an accelerometer configuration measurement model that yields such a high measuring precision. In this paper, an accelerometer configuration to improve measurement accuracy is proposed. The corresponding calculation formulas of the angular acceleration were derived through theoretical analysis. A method is presented to minimize angular acceleration noise based on analysis of the root mean square noise of the angular acceleration. Moreover, the influence of installation position errors and accelerometer orientation errors on the calculation precision of the angular acceleration is studied. Comparisons of the output differences between the proposed configuration and the previous planar triangle configuration under the same installation errors are conducted by simulation. The simulation results show that installation errors have a relatively small impact on the calculation accuracy of the proposed configuration. To further verify the high calculation precision of the proposed configuration, experiments are carried out for both the proposed configuration and the planar triangle configuration. On the basis of the results of simulations and experiments, it can be concluded that the proposed configuration has higher angular acceleration calculation precision and can be applied to different platforms.
Measurement Model and Precision Analysis of Accelerometers for Maglev Vibration Isolation Platforms
Wu, Qianqian; Yue, Honghao; Liu, Rongqiang; Zhang, Xiaoyou; Ding, Liang; Liang, Tian; Deng, Zongquan
2015-01-01
High precision measurement of acceleration levels is required to allow active control for vibration isolation platforms. It is necessary to propose an accelerometer configuration measurement model that yields such a high measuring precision. In this paper, an accelerometer configuration to improve measurement accuracy is proposed. The corresponding calculation formulas of the angular acceleration were derived through theoretical analysis. A method is presented to minimize angular acceleration noise based on analysis of the root mean square noise of the angular acceleration. Moreover, the influence of installation position errors and accelerometer orientation errors on the calculation precision of the angular acceleration is studied. Comparisons of the output differences between the proposed configuration and the previous planar triangle configuration under the same installation errors are conducted by simulation. The simulation results show that installation errors have a relatively small impact on the calculation accuracy of the proposed configuration. To further verify the high calculation precision of the proposed configuration, experiments are carried out for both the proposed configuration and the planar triangle configuration. On the basis of the results of simulations and experiments, it can be concluded that the proposed configuration has higher angular acceleration calculation precision and can be applied to different platforms. PMID:26287203
NASA Astrophysics Data System (ADS)
Wang, H. H.; Shi, Y. P.; Li, X. H.; Ni, K.; Zhou, Q.; Wang, X. H.
2018-03-01
In this paper, a scheme to measure the position of precision stages, with a high precision, is presented. The encoder is composed of a scale grating and a compact two-probe reading head, to read the zero position pulse signal and continuous incremental displacement signal. The scale grating contains different codes, multiple reference codes with different spacing superimposed onto the incremental grooves with an equal spacing structure. The codes of reference mask in the reading head is the same with the reference codes on the scale grating, and generate pulse signal to locate the reference position primarily when the reading head moves along the scale grating. After locating the reference position in a section by means of the pulse signal, the reference position can be located precisely with the amplitude of the incremental displacement signal. A kind of reference codes and scale grating were designed, and experimental results show that the primary precision of the design achieved is 1 μ m. The period of the incremental signal is 1μ m, and 1000/N nm precision can be achieved by subdivide the incremental signal in N times.
Precision Medicine for Heart Failure with Preserved Ejection Fraction: An Overview.
Shah, Sanjiv J
2017-06-01
There are few proven therapies for heart failure with preserved ejection fraction (HFpEF). The lack of therapies, along with increased recognition of the disorder and its underlying pathophysiology, has led to the acknowledgement that HFpEF is heterogeneous and is not likely to respond to a one-size-fits-all approach. Thus, HFpEF is a prime candidate to benefit from a precision medicine approach. For this reason, we have assembled a compendium of papers on the topic of precision medicine in HFpEF in the Journal of Cardiovascular Translational Research. These papers cover a variety of topics relevant to precision medicine in HFpEF, including automated identification of HFpEF patients; machine learning, novel molecular approaches, genomics, and deep phenotyping of HFpEF; and clinical trial designs that can be used to advance precision medicine in HFpEF. In this introductory article, we provide an overview of precision medicine in HFpEF with the hope that the work described here and in the other papers in this special theme issue will stimulate investigators and clinicians to advance a more targeted approach to HFpEF classification and treatment.
Precision medicine for advanced prostate cancer
Mullane, Stephanie A.; Van Allen, Eliezer M.
2016-01-01
Purpose of review Precision cancer medicine, the use of genomic profiling of patient tumors at the point-of-care to inform treatment decisions, is rapidly changing treatment strategies across cancer types. Precision medicine for advanced prostate cancer may identify new treatment strategies and change clinical practice. In this review, we discuss the potential and challenges of precision medicine in advanced prostate cancer. Recent findings Although primary prostate cancers do not harbor highly recurrent targetable genomic alterations, recent reports on the genomics of metastatic castration-resistant prostate cancer has shown multiple targetable alterations in castration-resistant prostate cancer metastatic biopsies. Therapeutic implications include targeting prevalent DNA repair pathway alterations with PARP-1 inhibition in genomically defined subsets of patients, among other genomically stratified targets. In addition, multiple recent efforts have demonstrated the promise of liquid tumor profiling (e.g., profiling circulating tumor cells or cell-free tumor DNA) and highlighted the necessary steps to scale these approaches in prostate cancer. Summary Although still in the initial phase of precision medicine for prostate cancer, there is extraordinary potential for clinical impact. Efforts to overcome current scientific and clinical barriers will enable widespread use of precision medicine approaches for advanced prostate cancer patients. PMID:26909474
Precision Medicine for Heart Failure with Preserved Ejection Fraction: An Overview
Shah, Sanjiv J.
2017-01-01
There are few proven therapies for heart failure with preserved ejection fraction (HFpEF). The lack of therapies, along with increased recognition of the disorder and its underlying pathophysiology, has led to the acknowledgement that HFpEF is heterogeneous and is not likely to respond to a one-size-fits-all approach. Thus, HFpEF is a prime candidate to benefit from a precision medicine approach. For this reason, we have assembled a compendium of papers on the topic of precision medicine in HFpEF in the Journal of Cardiovascular Translational Research. These papers cover a variety of topics relevant to precision medicine in HFpEF, including automated identification of HFpEF patients; machine learning, novel molecular approaches, genomics, and deep phenotyping of HFpEF; and clinical trial designs that can be used to advance precision medicine in HFpEF. In this introductory article, we provide an overview of precision medicine in HFpEF with the hope that the work described here and in the other papers in this special theme issue will stimulate investigators and clinicians to advance a more targeted approach to HFpEF classification and treatment. PMID:28585183
The Challenges of Precision Medicine in COPD.
Cazzola, Mario; Calzetta, Luigino; Rogliani, Paola; Matera, Maria Gabriella
2017-08-01
Pheno-/endotyping chronic obstructive pulmonary disease (COPD) is really important because it provides patients with precise and personalized medicine. The central concept of precision medicine is to take individual variability into account when making management decisions. Precision medicine should ensure that patients get the right treatment at the right dose at the right time, with minimum harmful consequences and maximum efficacy. Ideally, we should search for genetic and molecular biomarker-based profiles. Given the clinical complexity of COPD, it seems likely that a panel of several biomarkers will be required to characterize pathogenetic factors and their course over time. The need for biomarkers to guide the clinical care of individuals with COPD and to enhance the possibilities of success in drug development is clear and urgent, but biomarker development is tremendously challenging and expensive, and translation of research efforts to date has been largely ineffective. Furthermore, the development of personalized treatments will require a much more detailed understanding of the clinical and biological heterogeneity of COPD. Therefore, we are still far from being able to apply precision medicine in COPD and the treatable traits and FEV 1 -free approaches are attempts to precision medicine in COPD that must be considered still quite unsophisticated.
Precision Medicine in Gastrointestinal Pathology.
Wang, David H; Park, Jason Y
2016-05-01
-Precision medicine is the promise of individualized therapy and management of patients based on their personal biology. There are now multiple global initiatives to perform whole-genome sequencing on millions of individuals. In the United States, an early program was the Million Veteran Program, and a more recent proposal in 2015 by the president of the United States is the Precision Medicine Initiative. To implement precision medicine in routine oncology care, genetic variants present in tumors need to be matched with effective clinical therapeutics. When we focus on the current state of precision medicine for gastrointestinal malignancies, it becomes apparent that there is a mixed history of success and failure. -To present the current state of precision medicine using gastrointestinal oncology as a model. We will present currently available targeted therapeutics, promising new findings in clinical genomic oncology, remaining quality issues in genomic testing, and emerging oncology clinical trial designs. -Review of the literature including clinical genomic studies on gastrointestinal malignancies, clinical oncology trials on therapeutics targeted to molecular alterations, and emerging clinical oncology study designs. -Translating our ability to sequence thousands of genes into meaningful improvements in patient survival will be the challenge for the next decade.
Precision medicine for advanced prostate cancer.
Mullane, Stephanie A; Van Allen, Eliezer M
2016-05-01
Precision cancer medicine, the use of genomic profiling of patient tumors at the point-of-care to inform treatment decisions, is rapidly changing treatment strategies across cancer types. Precision medicine for advanced prostate cancer may identify new treatment strategies and change clinical practice. In this review, we discuss the potential and challenges of precision medicine in advanced prostate cancer. Although primary prostate cancers do not harbor highly recurrent targetable genomic alterations, recent reports on the genomics of metastatic castration-resistant prostate cancer has shown multiple targetable alterations in castration-resistant prostate cancer metastatic biopsies. Therapeutic implications include targeting prevalent DNA repair pathway alterations with PARP-1 inhibition in genomically defined subsets of patients, among other genomically stratified targets. In addition, multiple recent efforts have demonstrated the promise of liquid tumor profiling (e.g., profiling circulating tumor cells or cell-free tumor DNA) and highlighted the necessary steps to scale these approaches in prostate cancer. Although still in the initial phase of precision medicine for prostate cancer, there is extraordinary potential for clinical impact. Efforts to overcome current scientific and clinical barriers will enable widespread use of precision medicine approaches for advanced prostate cancer patients.
Scott, Jessica A; Hoffmeister, Robert J
2018-04-01
Academic English is an essential literacy skill area for success in post-secondary education and in many work environments. Despite its importance, academic English is understudied with deaf and hard of hearing (DHH) students. Nascent research in this area suggests that academic English, alongside American Sign Language (ASL) fluency, may play an important role in the reading proficiency of DHH students in middle and high school. The current study expands this research to investigate academic English by examining student proficiency with a sub-skill of academic writing called superordinate precision, the taxonomical categorization of a term. Currently there is no research that examines DHH students' proficiency with superordinate precision. Middle and high school DHH students enrolled in bilingual schools for the deaf were assessed on their ASL proficiency, academic English proficiency, reading comprehension, and use of superordinate precision in definitions writing. Findings indicate that student use of superordinate precision in definitions writing was correlated with ASL proficiency, reading comprehension, and academic English proficiency. It is possible that degree of mastery of superordinate precision may indicate a higher overall level of proficiency with academic English. This may have important implications for assessment of and instruction in academic English literacy.
NASA Astrophysics Data System (ADS)
Sánchez, Daniel; Nieh, James C.; Hénaut, Yann; Cruz, Leopoldo; Vandame, Rémy
Several studies have examined the existence of recruitment communication mechanisms in stingless bees. However, the spatial accuracy of location-specific recruitment has not been examined. Moreover, the location-specific recruitment of reactivated foragers, i.e., foragers that have previously experienced the same food source at a different location and time, has not been explicitly examined. However, such foragers may also play a significant role in colony foraging, particularly in small colonies. Here we report that reactivated Scaptotrigona mexicana foragers can recruit with high precision to a specific food location. The recruitment precision of reactivated foragers was evaluated by placing control feeders to the left and the right of the training feeder (direction-precision tests) and between the nest and the training feeder and beyond it (distance-precision tests). Reactivated foragers arrived at the correct location with high precision: 98.44% arrived at the training feeder in the direction trials (five-feeder fan-shaped array, accuracy of at least +/-6° of azimuth at 50 m from the nest), and 88.62% arrived at the training feeder in the distance trials (five-feeder linear array, accuracy of at least +/-5 m or +/-10% at 50 m from the nest). Thus, S. mexicana reactivated foragers can find the indicated food source at a specific distance and direction with high precision, higher than that shown by honeybees, Apis mellifera, which do not communicate food location at such close distances to the nest.
Dickie, Ben R; Banerji, Anita; Kershaw, Lucy E; McPartlin, Andrew; Choudhury, Ananya; West, Catharine M; Rose, Chris J
2016-10-01
To improve the accuracy and precision of tracer kinetic model parameter estimates for use in dynamic contrast enhanced (DCE) MRI studies of solid tumors. Quantitative DCE-MRI requires an estimate of precontrast T1 , which is obtained prior to fitting a tracer kinetic model. As T1 mapping and tracer kinetic signal models are both a function of precontrast T1 it was hypothesized that its joint estimation would improve the accuracy and precision of both precontrast T1 and tracer kinetic model parameters. Accuracy and/or precision of two-compartment exchange model (2CXM) parameters were evaluated for standard and joint fitting methods in well-controlled synthetic data and for 36 bladder cancer patients. Methods were compared under a number of experimental conditions. In synthetic data, joint estimation led to statistically significant improvements in the accuracy of estimated parameters in 30 of 42 conditions (improvements between 1.8% and 49%). Reduced accuracy was observed in 7 of the remaining 12 conditions. Significant improvements in precision were observed in 35 of 42 conditions (between 4.7% and 50%). In clinical data, significant improvements in precision were observed in 18 of 21 conditions (between 4.6% and 38%). Accuracy and precision of DCE-MRI parameter estimates are improved when signal models are fit jointly rather than sequentially. Magn Reson Med 76:1270-1281, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Precision measurements on trapped antihydrogen in the ALPHA experiment
NASA Astrophysics Data System (ADS)
Eriksson, S.
2018-03-01
Both the 1S-2S transition and the ground state hyperfine spectrum have been observed in trapped antihydrogen. The former constitutes the first observation of resonant interaction of light with an anti-atom, and the latter is the first detailed measurement of a spectral feature in antihydrogen. Owing to the narrow intrinsic linewidth of the 1S-2S transition and use of two-photon laser excitation, the transition energy can be precisely determined in both hydrogen and antihydrogen, allowing a direct comparison as a test of fundamental symmetry. The result is consistent with CPT invariance at a relative precision of around 2×10-10. This constitutes the most precise measurement of a property of antihydrogen. The hyperfine spectrum of antihydrogen is determined to a relative uncertainty of 4×10-4. The excited state and the hyperfine spectroscopy techniques currently both show sensitivity at the few 100 kHz level on the absolute scale. Here, the most recent work of the ALPHA collaboration on precision spectroscopy of antihydrogen is presented together with an outlook on improving the precision of measurements involving lasers and microwave radiation. Prospects of measuring the Lamb shift and determining the antiproton charge radius in trapped antihydrogen in the ALPHA apparatus are presented. Future perspectives of precision measurements of trapped antihydrogen in the ALPHA apparatus when the ELENA facility becomes available to experiments at CERN are discussed. This article is part of the Theo Murphy meeting issue `Antiproton physics in the ELENA era'.
Towards precision medicine; a new biomedical cosmology.
Vegter, M W
2018-02-10
Precision Medicine has become a common label for data-intensive and patient-driven biomedical research. Its intended future is reflected in endeavours such as the Precision Medicine Initiative in the USA. This article addresses the question whether it is possible to discern a new 'medical cosmology' in Precision Medicine, a concept that was developed by Nicholas Jewson to describe comprehensive transformations involving various dimensions of biomedical knowledge and practice, such as vocabularies, the roles of patients and physicians and the conceptualisation of disease. Subsequently, I will elaborate my assessment of the features of Precision Medicine with the help of Michel Foucault, by exploring how precision medicine involves a transformation along three axes: the axis of biomedical knowledge, of biomedical power and of the patient as a self. Patients are encouraged to become the managers of their own health status, while the medical domain is reframed as a data-sharing community, characterised by changing power relationships between providers and patients, producers and consumers. While the emerging Precision Medicine cosmology may surpass existing knowledge frameworks; it obscures previous traditions and reduces research-subjects to mere data. This in turn, means that the individual is both subjected to the neoliberal demand to share personal information, and at the same time has acquired the positive 'right' to become a member of the data-sharing community. The subject has to constantly negotiate the meaning of his or her data, which can either enable self-expression, or function as a commanding Superego.
Digital PCR Modeling for Maximal Sensitivity, Dynamic Range and Measurement Precision
Majumdar, Nivedita; Wessel, Thomas; Marks, Jeffrey
2015-01-01
The great promise of digital PCR is the potential for unparalleled precision enabling accurate measurements for genetic quantification. A challenge associated with digital PCR experiments, when testing unknown samples, is to perform experiments at dilutions allowing the detection of one or more targets of interest at a desired level of precision. While theory states that optimal precision (Po) is achieved by targeting ~1.59 mean copies per partition (λ), and that dynamic range (R) includes the space spanning one positive (λL) to one negative (λU) result from the total number of partitions (n), these results are tempered for the practitioner seeking to construct digital PCR experiments in the laboratory. A mathematical framework is presented elucidating the relationships between precision, dynamic range, number of partitions, interrogated volume, and sensitivity in digital PCR. The impact that false reaction calls and volumetric variation have on sensitivity and precision is next considered. The resultant effects on sensitivity and precision are established via Monte Carlo simulations reflecting the real-world likelihood of encountering such scenarios in the laboratory. The simulations provide insight to the practitioner on how to adapt experimental loading concentrations to counteract any one of these conditions. The framework is augmented with a method of extending the dynamic range of digital PCR, with and without increasing n, via the use of dilutions. An example experiment demonstrating the capabilities of the framework is presented enabling detection across 3.33 logs of starting copy concentration. PMID:25806524
ERIC Educational Resources Information Center
Spencer, Bryden
2016-01-01
Value-added models are a class of growth models used in education to assign responsibility for student growth to teachers or schools. For value-added models to be used fairly, sufficient statistical precision is necessary for accurate teacher classification. Previous research indicated precision below practical limits. An alternative approach has…
Test of CCD Precision Limits for Differential Photometry
NASA Technical Reports Server (NTRS)
Robinson, L. B.; Wei, M. Z.; Borucki, W. J.; Dunham, E. W.; Ford, C. H.; Granados, A. F.
1995-01-01
Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 10(exp 5). Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.
ERIC Educational Resources Information Center
Freeze, Rick; Cook, Paula
2005-01-01
The purpose of this study was to assess the efficacy and practicality of precision reading, a constructive reading intervention, with students with cognitive impairments, extreme academic deficits in reading, and severe social, emotional, and psychiatric problems. As precision reading had shown promise with students with low achievement, learning…
Quality control of estrogen receptor assays.
Godolphin, W; Jacobson, B
1980-01-01
Four types of material have been used for the quality control of routine assays of estrogen receptors in human breast tumors. Pieces of hormone-dependent Nb rat mammary tumors gave a precision about 40%. Rat uteri and rat tumors pulverized at liquid nitrogen temperature and stored as powder yielded precision about 30%. Powdered and lyophilised human tumors appear the best with precision as good as 17%.
Precision displacement reference system
Bieg, Lothar F.; Dubois, Robert R.; Strother, Jerry D.
2000-02-22
A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.
Precision, accuracy, and efficiency of four tools for measuring soil bulk density or strength.
Richard E. Miller; John Hazard; Steven Howes
2001-01-01
Monitoring soil compaction is time consuming. A desire for speed and lower costs, however, must be balanced with the appropriate precision and accuracy required of the monitoring task. We compared three core samplers and a cone penetrometer for measuring soil compaction after clearcut harvest on a stone-free and a stony soil. Precision (i.e., consistency) of each tool...
The Nature of the Nodes, Weights and Degree of Precision in Gaussian Quadrature Rules
ERIC Educational Resources Information Center
Prentice, J. S. C.
2011-01-01
We present a comprehensive proof of the theorem that relates the weights and nodes of a Gaussian quadrature rule to its degree of precision. This level of detail is often absent in modern texts on numerical analysis. We show that the degree of precision is maximal, and that the approximation error in Gaussian quadrature is minimal, in a…
Precision gap particle separator
Benett, William J.; Miles, Robin; Jones, II., Leslie M.; Stockton, Cheryl
2004-06-08
A system for separating particles entrained in a fluid includes a base with a first channel and a second channel. A precision gap connects the first channel and the second channel. The precision gap is of a size that allows small particles to pass from the first channel into the second channel and prevents large particles from the first channel into the second channel. A cover is positioned over the base unit, the first channel, the precision gap, and the second channel. An port directs the fluid containing the entrained particles into the first channel. An output port directs the large particles out of the first channel. A port connected to the second channel directs the small particles out of the second channel.
Precision and fast wavelength tuning of a dynamically phase-locked widely-tunable laser.
Numata, Kenji; Chen, Jeffrey R; Wu, Stewart T
2012-06-18
We report a precision and fast wavelength tuning technique demonstrated for a digital-supermode distributed Bragg reflector laser. The laser was dynamically offset-locked to a frequency-stabilized master laser using an optical phase-locked loop, enabling precision fast tuning to and from any frequencies within a ~40-GHz tuning range. The offset frequency noise was suppressed to the statically offset-locked level in less than ~40 μs upon each frequency switch, allowing the laser to retain the absolute frequency stability of the master laser. This technique satisfies stringent requirements for gas sensing lidars and enables other applications that require such well-controlled precision fast tuning.
High precision spectroscopy and imaging in THz frequency range
NASA Astrophysics Data System (ADS)
Vaks, Vladimir L.
2014-03-01
Application of microwave methods for development of the THz frequency range has resulted in elaboration of high precision THz spectrometers based on nonstationary effects. The spectrometers characteristics (spectral resolution and sensitivity) meet the requirements for high precision analysis. The gas analyzers, based on the high precision spectrometers, have been successfully applied for analytical investigations of gas impurities in high pure substances. These investigations can be carried out both in absorption cell and in reactor. The devices can be used for ecological monitoring, detecting the components of chemical weapons and explosive in the atmosphere. The great field of THz investigations is the medicine application. Using the THz spectrometers developed one can detect markers for some diseases in exhaled air.
High-Precision Half-Life Measurements for the Superallowed Fermi β+ Emitters 14O and 18Ne
NASA Astrophysics Data System (ADS)
Laffoley, A. T.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bender, P. C.; Bidaman, H.; Bildstein, V.; Blank, B.; Bouzomita, H.; Cross, D. S.; Deng, G.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P.; Giovinazzo, J.; Grinyer, G. F.; Grinyer, J.; Hadinia, B.; Jamieson, D. S.; Jigmeddorj, B.; Ketelhut, S.; Kisliuk, D.; Leach, K. G.; Leslie, J. R.; MacLean, A.; Miller, D.; Mills, B.; Moukaddam, M.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Svensson, C. E.; Tardiff, E.; Thomas, J. C.; Turko, J.; Voss, P.; Unsworth, C.
High-precision half-life measurements, at the level of ±0.04%, for the superallowed Fermi emitters 14O and 18Ne have been performed at TRIUMF's Isotope Separator and Accelerator facility. Using 3 independent detector systems, a gas-proportional counter, a fast plastic scintillator, and a high-purity germanium array, a series of direct β and γ counting measurements were performed for each of the isotopes. In the case of 14O, these measurements were made to help resolve an existing discrepancy between detection methods, whereas for 18Ne the half-life precision has been improved in anticipation of forthcoming high-precision branching ratio measurements.
Alignment of a vector magnetometer to an optical prism
NASA Astrophysics Data System (ADS)
Dietrich, M. R.; Bailey, K. G.; O'Connor, T. P.
2017-05-01
A method for alignment of a vector magnetometer to a rigidly attached prism is presented. This enables optical comparison of the magnetometer axes to physical surfaces in the apparatus, and thus an absolute determination of the magnetic field direction in space. This is in contrast with more common techniques, which focus on precise determination of the relative angles between magnetometer axes, and so are more suited to measuring differences in the direction of magnetic fields. Here we demonstrate precision better than 500 μrad on a fluxgate magnetometer, which also gives the coil orthogonality errors to a similar precision. The relative sensitivity of the three axes is also determined, with a precision of about 5 ×10 -4 .
NASA Astrophysics Data System (ADS)
Yang, Ying; Liu, Xiaobao; Wang, Jieci; Jing, Jiliang
2018-03-01
We study how to improve the precision of the quantum estimation of phase for an uniformly accelerated atom in fluctuating electromagnetic field by reflecting boundaries. We find that the precision decreases with increases of the acceleration without the boundary. With the presence of a reflecting boundary, the precision depends on the atomic polarization, position and acceleration, which can be effectively enhanced compared to the case without boundary if we choose the appropriate conditions. In particular, with the presence of two parallel reflecting boundaries, we obtain the optimal precision for atomic parallel polarization and the special distance between two boundaries, as if the atom were shielded from the fluctuation.
Precision thermometry and the quantum speed limit
NASA Astrophysics Data System (ADS)
Campbell, Steve; Genoni, Marco G.; Deffner, Sebastian
2018-04-01
We assess precision thermometry for an arbitrary single quantum system. For a d-dimensional harmonic system we show that the gap sets a single temperature that can be optimally estimated. Furthermore, we establish a simple linear relationship between the gap and this temperature, and show that the precision exhibits a quadratic relationship. We extend our analysis to explore systems with arbitrary spectra, showing that exploiting anharmonicity and degeneracy can greatly enhance the precision of thermometry. Finally, we critically assess the dynamical features of two thermometry protocols for a two level system. By calculating the quantum speed limit we find that, despite the gap fixing a preferred temperature to probe, there is no evidence of this emerging in the dynamical features.
Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma.
Wright, Chadwick L; Maly, Joseph J; Zhang, Jun; Knopp, Michael V
2017-01-01
PET with fluorodeoxyglucose F 18 ( 18 F FDG-PET) is a meaningful biomarker for the detection, targeted biopsy, and treatment of lymphoma. This article reviews the evolution of 18 F FDG-PET as a putative biomarker for lymphoma and addresses the current capabilities, challenges, and opportunities to enable precision medicine practices for lymphoma. Precision nuclear medicine is driven by new imaging technologies and methodologies to more accurately detect malignant disease. Although quantitative assessment of response is limited, such technologies will enable a more precise metabolic mapping with much higher definition image detail and thus may make it a robust and valid quantitative response assessment methodology. Copyright © 2016 Elsevier Inc. All rights reserved.
[Medical imaging in tumor precision medicine: opportunities and challenges].
Xu, Jingjing; Tan, Yanbin; Zhang, Minming
2017-05-25
Tumor precision medicine is an emerging approach for tumor diagnosis, treatment and prevention, which takes account of individual variability of environment, lifestyle and genetic information. Tumor precision medicine is built up on the medical imaging innovations developed during the past decades, including the new hardware, new imaging agents, standardized protocols, image analysis and multimodal imaging fusion technology. Also the development of automated and reproducible analysis algorithm has extracted large amount of information from image-based features. With the continuous development and mining of tumor clinical and imaging databases, the radiogenomics, radiomics and artificial intelligence have been flourishing. Therefore, these new technological advances bring new opportunities and challenges to the application of imaging in tumor precision medicine.
Precision measurements of linear scattering density using muon tomography
NASA Astrophysics Data System (ADS)
Åström, E.; Bonomi, G.; Calliari, I.; Calvini, P.; Checchia, P.; Donzella, A.; Faraci, E.; Forsberg, F.; Gonella, F.; Hu, X.; Klinger, J.; Sundqvist Ökvist, L.; Pagano, D.; Rigoni, A.; Ramous, E.; Urbani, M.; Vanini, S.; Zenoni, A.; Zumerle, G.
2016-07-01
We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.
Achieving High Resolution Timer Events in Virtualized Environment
Adamczyk, Blazej; Chydzinski, Andrzej
2015-01-01
Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs—Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events. PMID:26177366
Kinematic precision of gear trains
NASA Technical Reports Server (NTRS)
Litvin, F. L.; Goldrich, R. N.; Coy, J. J.; Zaretsky, E. V.
1983-01-01
Kinematic precision is affected by errors which are the result of either intentional adjustments or accidental defects in manufacturing and assembly of gear trains. A method for the determination of kinematic precision of gear trains is described. The method is based on the exact kinematic relations for the contact point motions of the gear tooth surfaces under the influence of errors. An approximate method is also explained. Example applications of the general approximate methods are demonstrated for gear trains consisting of involute (spur and helical) gears, circular arc (Wildhaber-Novikov) gears, and spiral bevel gears. Gear noise measurements from a helicopter transmission are presented and discussed with relation to the kinematic precision theory. Previously announced in STAR as N82-32733
Fabrication and Metrology of High-Precision Foil Mirror Mounting Elements
NASA Technical Reports Server (NTRS)
Schattenburg, Mark L.
2002-01-01
During the period of this Cooperative Agreement, MIT (Massachusetts Institute of Technology) developed advanced methods for applying silicon microstructures for the precision assembly of foil x-ray optics in support of the Constellation-X Spectroscopy X-ray Telescope (SXT) development effort at Goddard Space Flight Center (GSFC). MIT developed improved methods for fabricating and characterizing the precision silicon micro-combs. MIT also developed and characterized assembly tools and several types of metrology tools in order to characterize and reduce the errors associated with precision assembly of foil optics. Results of this effort were published and presented to the scientific community and the GSFC SXT team. A bibliography of papers and presentations is offered.
Morphologies of precise polyethylene-based acid copolymers and ionomers
NASA Astrophysics Data System (ADS)
Buitrago, C. Francisco
Acid copolymers and ionomers are polymers that contain a small fraction of covalently bound acidic or ionic groups, respectively. For the specific case of polyethylene (PE), acid and ionic pendants enhance many of the physical properties such as toughness, adhesion and rheological properties. These improved properties result from microphase separated aggregates of the polar pendants in the non-polar PE matrix. Despite the widespread industrial use of these materials, rigorous chemical structure---morphology---property relationships remain elusive due to the inevitable structural heterogeneities in the historically-available acid copolymers and ionomers. Recently, precise acid copolymers and ionomers were successfully synthesized by acyclic diene metathesis (ADMET) polymerization. These precise materials are linear, high molecular weight PEs with pendant acid or ionic functional groups separated by a precisely controlled number of carbon atoms. The morphologies of nine precise acid copolymers and eleven precise ionomers were investigated by X-ray scattering, solid-state 13C nuclear magnetic resonance (NMR) and differential scanning calorimetry (DSC). For comparison, the morphologies of linear PEs with pseudo-random placement of the pendant groups were also studied. Previous studies of precise copolymers with acrylic acid (AA) found that the microstructural precision produces a new morphology in which PE crystals drive the acid aggregates into layers perpendicular to the chain axes and presumably at the interface between crystalline and amorphous phases. In this dissertation, a second new morphology for acid copolymers is identified in which the aggregates arrange on cubic lattices. The fist report of a cubic morphology was observed at room and elevated temperatures for a copolymer functionalized with two phosphonic acid (PA) groups on every 21st carbon atom. The cubic lattice has been identified as face-centered cubic (FCC). Overall, three morphology types have been identified for precise acid copolymers and ionomers at room temperature: (1) liquid-like order of aggregates dispersed throughout an amorphous PE matrix, (2) one-dimensional long-range order of aggregates in layers coexisting with PE crystals, and (3) three-dimensional periodicity of aggregates in cubic lattices in a PE matrix featuring defective packing. The liquid-like morphology is a result of high content of acid or ionic substituents deterring PE crystallinity due to steric hindrance. The layered morphology occurs when the content of pendants is low and the PE segments are long enough to crystallize. The cubic morphologies occur in precise copolymers with geminal substitution of phosphonic acid (PA) groups and long, flexible PE segments. At temperatures above the thermal transitions of the PE matrix, all but one material present a liquid-like morphology. Those conditions are ideal to study the evolution of the interaggregate spacing (d*) in X-ray scattering as a function of PE segment length between pendants, pendant type and pendant architecture (specifically, mono or geminal substitution). Also at elevated temperatures, the morphologies of precise acrylic acid (AA) copolymers and ionomers were investigated further via atomistic molecular dynamics (MD) simulations. The simulations complement X-ray scattering by providing real space visualization of the aggregates, demonstrating the occurrence of isolated, string-like and even percolated aggregate structures. This is the first dissertation completely devoted to the morphology of precise acid copolymers and precise ionomers. The complete analysis of the morphologies in these novel materials provides new insights into the shapes of aggregates in acid copolymers and ionomers in general. A key aspect of this thesis is the complementary use of experimental and simulation methods to unlock a wealth of new understanding.
Achieving quantum precision limit in adaptive qubit state tomography
NASA Astrophysics Data System (ADS)
Hou, Zhibo; Zhu, Huangjun; Xiang, Guo-Yong; Li, Chuan-Feng; Guo, Guang-Can
2016-02-01
The precision limit in quantum state tomography is of great interest not only to practical applications but also to foundational studies. However, little is known about this subject in the multiparameter setting even theoretically due to the subtle information trade-off among incompatible observables. In the case of a qubit, the theoretic precision limit was determined by Hayashi as well as Gill and Massar, but attaining the precision limit in experiments has remained a challenging task. Here we report the first experiment that achieves this precision limit in adaptive quantum state tomography on optical polarisation qubits. The two-step adaptive strategy used in our experiment is very easy to implement in practice. Yet it is surprisingly powerful in optimising most figures of merit of practical interest. Our study may have significant implications for multiparameter quantum estimation problems, such as quantum metrology. Meanwhile, it may promote our understanding about the complementarity principle and uncertainty relations from the information theoretic perspective.
High-precision relative position and attitude measurement for on-orbit maintenance of spacecraft
NASA Astrophysics Data System (ADS)
Zhu, Bing; Chen, Feng; Li, Dongdong; Wang, Ying
2018-02-01
In order to realize long-term on-orbit running of satellites, space stations, etc spacecrafts, in addition to the long life design of devices, The life of the spacecraft can also be extended by the on-orbit servicing and maintenance. Therefore, it is necessary to keep precise and detailed maintenance of key components. In this paper, a high-precision relative position and attitude measurement method used in the maintenance of key components is given. This method mainly considers the design of the passive cooperative marker, light-emitting device and high resolution camera in the presence of spatial stray light and noise. By using a series of algorithms, such as background elimination, feature extraction, position and attitude calculation, and so on, the high precision relative pose parameters as the input to the control system between key operation parts and maintenance equipment are obtained. The simulation results show that the algorithm is accurate and effective, satisfying the requirements of the precision operation technique.
NASA Astrophysics Data System (ADS)
Shimura, Kazuo; Nakajima, Nobuyoshi; Tanaka, Hiroshi; Ishida, Masamitsu; Kato, Hisatoyo
1993-09-01
Dual-energy X-ray absorptiometry (DXA) is one of the bone densitometry techniques to diagnose osteoporosis, and has been gradually getting popular due to its high degree of precision. However, DXA involves a time-consuming examination because of its pencil-beam scan, and the equipment is expensive. In this study, we examined a new bone densitometry technique (CR-DXA) utilizing an X-ray imaging system and Computed Radiography (CR) used for medical X-ray image diagnosis. High level of measurement precision and accuracy could be achieved by X-ray rube voltage/filter optimization and various nonuniformity corrections based on simulation and experiment. The phantom study using a bone mineral block showed precision of 0.83% c.v. (coefficient of variation), and accuracy of 0.01 g/cm2, suggesting that a practically equivalent degree of measurement precision and accuracy to that of the DXA approach is achieved. CR-DXA is considered to provide bone mineral densitometry to facilitate simple, quick and precise bone mineral density measurement.
NASA Astrophysics Data System (ADS)
Berrada, K.; Eleuch, H.
2017-09-01
Various schemes have been proposed to improve the parameter-estimation precision. In the present work, we suggest an alternative method to preserve the estimation precision by considering a model that closely describes a realistic experimental scenario. We explore this active way to control and enhance the measurements precision for a two-level quantum system interacting with classical electromagnetic field using ultra-short strong pulses with an exact analytical solution, i.e. beyond the rotating wave approximation. In particular, we investigate the variation of the precision with a few cycles pulse and a smooth phase jump over a finite time interval. We show that by acting on the shape of the phase transient and other parameters of the considered system, the amount of information may be increased and has smaller decay rate in the long time. These features make two-level systems incorporated in ultra-short, of-resonant and gradually changing phase good candidates for implementation of schemes for the quantum computation and the coherent information processing.
Proceedings of the 8th Precise Time and Time Interval (PTTI) Applications and Planning Meeting
NASA Technical Reports Server (NTRS)
1977-01-01
The Proceedings contain the papers presented at the Eight Annual Precise Time and Tme Interval PTTI Applications and Planning Meeting. The edited record of the discussions following the papers and the panel discussions are also included. This meeting provided a forum for the exchange of information on precise time and frequency technology among members of the scientific community and persons with program applications. The 282 registered attendees came from various U.S. Government agencies, private industry, universities and a number of foreign countries were represented. In this meeting, papers were presented that emphasized: (1) definitions and international regulations of precise time sources and users, (2) the scientific foundations of Hydrogen Maser standards, the current developments in this field and the application experience, and (3) how to measure the stability performance properties of precise standards. As in the previous meetings, update and new papers were presented on system applications with past, present and future requirements identified.
Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m
NASA Astrophysics Data System (ADS)
Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Grinyer, G. F.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.
2009-10-01
The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada. A beam of ˜10^5 ^26Al^m/s was delivered in October 2007 and its decay was observed using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [4pt] [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 79, 055502 (2009).
Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m
NASA Astrophysics Data System (ADS)
Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Leslie, J. R.
2008-10-01
The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada, which delivered a beam of ˜10^5 ^26Al^m/s in October 2007. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 77, 025501 (2008).
Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J
2015-01-01
Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy. PMID:25628867
Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J
2015-01-01
Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy.
Teodoro, P E; Torres, F E; Santos, A D; Corrêa, A M; Nascimento, M; Barroso, L M A; Ceccon, G
2016-05-09
The aim of this study was to evaluate the suitability of statistics as experimental precision degree measures for trials with cowpea (Vigna unguiculata L. Walp.) genotypes. Cowpea genotype yields were evaluated in 29 trials conducted in Brazil between 2005 and 2012. The genotypes were evaluated with a randomized block design with four replications. Ten statistics that were estimated for each trial were compared using descriptive statistics, Pearson correlations, and path analysis. According to the class limits established, selective accuracy and F-test values for genotype, heritability, and the coefficient of determination adequately estimated the degree of experimental precision. Using these statistics, 86.21% of the trials had adequate experimental precision. Selective accuracy and the F-test values for genotype, heritability, and the coefficient of determination were directly related to each other, and were more suitable than the coefficient of variation and the least significant difference (by the Tukey test) to evaluate experimental precision in trials with cowpea genotypes.
Spachtholz, Philipp; Kuhbandner, Christof; Pekrun, Reinhard
2014-08-01
Research has shown that negative affect reduces working memory capacity. Commonly, this effect has been attributed to an allocation of resources to task-irrelevant thoughts, suggesting that negative affect has detrimental consequences for working memory performance. However, rather than simply being a detrimental effect, the affect-induced capacity reduction may reflect a trading of capacity for precision of stored representations. To test this hypothesis, we induced neutral or negative affect and concurrently measured the number and precision of representations stored in sensory and working memory. Compared with neutral affect, negative affect reduced the capacity of both sensory and working memory. However, in both memory systems, this decrease in capacity was accompanied by an increase in precision. These findings demonstrate that observers unintentionally trade capacity for precision as a function of affective state and indicate that negative affect can be beneficial for the quality of memories. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Butts, Daniel A; Weng, Chong; Jin, Jianzhong; Alonso, Jose-Manuel; Paninski, Liam
2011-08-03
Visual neurons can respond with extremely precise temporal patterning to visual stimuli that change on much slower time scales. Here, we investigate how the precise timing of cat thalamic spike trains-which can have timing as precise as 1 ms-is related to the stimulus, in the context of both artificial noise and natural visual stimuli. Using a nonlinear modeling framework applied to extracellular data, we demonstrate that the precise timing of thalamic spike trains can be explained by the interplay between an excitatory input and a delayed suppressive input that resembles inhibition, such that neuronal responses only occur in brief windows where excitation exceeds suppression. The resulting description of thalamic computation resembles earlier models of contrast adaptation, suggesting a more general role for mechanisms of contrast adaptation in visual processing. Thus, we describe a more complex computation underlying thalamic responses to artificial and natural stimuli that has implications for understanding how visual information is represented in the early stages of visual processing.
Chen, Guoli; Yang, Zhaohai; Eshleman, James R; Netto, George J; Lin, Ming-Tseh
2016-01-01
Precision medicine, a concept that has recently emerged and has been widely discussed, emphasizes tailoring medical care to individuals largely based on information acquired from molecular diagnostic testing. As a vital aspect of precision cancer medicine, targeted therapy has been proven to be efficacious and less toxic for cancer treatment. Colorectal cancer (CRC) is one of the most common cancers and among the leading causes for cancer related deaths in the United States and worldwide. By far, CRC has been one of the most successful examples in the field of precision cancer medicine, applying molecular tests to guide targeted therapy. In this review, we summarize the current guidelines for anti-EGFR therapy, revisit the roles of pathologists in an era of precision cancer medicine, demonstrate the transition from traditional "one test-one drug" assays to multiplex assays, especially by using next-generation sequencing platforms in the clinical diagnostic laboratories, and discuss the future perspectives of tumor heterogeneity associated with anti-EGFR resistance and immune checkpoint blockage therapy in CRC.
NASA Astrophysics Data System (ADS)
WANG, Qingrong; ZHU, Changfeng
2017-06-01
Integration of distributed heterogeneous data sources is the key issues under the big data applications. In this paper the strategy of variable precision is introduced to the concept lattice, and the one-to-one mapping mode of variable precision concept lattice and ontology concept lattice is constructed to produce the local ontology by constructing the variable precision concept lattice for each subsystem, and the distributed generation algorithm of variable precision concept lattice based on ontology heterogeneous database is proposed to draw support from the special relationship between concept lattice and ontology construction. Finally, based on the standard of main concept lattice of the existing heterogeneous database generated, a case study has been carried out in order to testify the feasibility and validity of this algorithm, and the differences between the main concept lattice and the standard concept lattice are compared. Analysis results show that this algorithm above-mentioned can automatically process the construction process of distributed concept lattice under the heterogeneous data sources.
A bio-physical basis of mathematics in synaptic function of the nervous system: a theory.
Dempsher, J
1980-01-01
The purpose of this paper is to present a bio-physical basis of mathematics. The essence of the theory is that function in the nervous system is mathematical. The mathematics arises as a result of the interaction of energy (a wave with a precise curvature in space and time) and matter (a molecular or ionic structure with a precise form in space and time). In this interaction, both energy and matter play an active role. That is, the interaction results in a change in form of both energy and matter. There are at least six mathematical operations in a simple synaptic region. It is believed the form of both energy and matter are specific, and their interaction is specific, that is, function in most of the 'mind' and placed where it belongs - in nature and the synaptic regions of the nervous system; it results in both places from a precise interaction between energy (in a precise form) and matter ( in a precise structure).
A new Ultra Precision Interferometer for absolute length measurements down to cryogenic temperatures
NASA Astrophysics Data System (ADS)
Schödel, R.; Walkov, A.; Zenker, M.; Bartl, G.; Meeß, R.; Hagedorn, D.; Gaiser, C.; Thummes, G.; Heltzel, S.
2012-09-01
A new Ultra Precision Interferometer (UPI) was built at Physikalisch-Technische Bundesanstalt. As its precursor, the precision interferometer, it was designed for highly precise absolute length measurements of prismatic bodies, e.g. gauge blocks, under well-defined temperature conditions and pressure, making use of phase stepping imaging interferometry. The UPI enables a number of enhanced features, e.g. it is designed for a much better lateral resolution and better temperature stability. In addition to the original concept, the UPI is equipped with an external measurement pathway (EMP) in which a prismatic body can be placed alternatively. The temperature of the EMP can be controlled in a much wider range compared to the temperature of the interferometer's main chamber. An appropriate cryostat system, a precision temperature measurement system and improved imaging interferometry were established to permit absolute length measurements down to cryogenic temperature, demonstrated for the first time ever. Results of such measurements are important for studying thermal expansion of materials from room temperature towards less than 10 K.
Precision experiments on mirror transitions at Notre Dame
NASA Astrophysics Data System (ADS)
Brodeur, Maxime; TwinSol Collaboration
2016-09-01
Thanks to extensive experimental efforts that led to a precise determination of important experimental quantities of superallowed pure Fermi transitions, we now have a very precise value for Vud that leads to a stringent test of the CKM matrix unitarity. Despite this achievement, measurements in other systems remain relevant as conflicting results could uncover unknown systematic effects or even new physics. One such system is the superallowed mixed transition, which can help refine theoretical corrections used for pure Fermi transitions and improve the accuracy of Vud. However, as a corrected Ft-value determination from these systems requires the more challenging determination of the Fermi Gamow-Teller mixing ratio, only five transitions, spreading from 19Ne to 37Ar, are currently fully characterized. To rectify the situation, an experimental program on precision experiment of mirror transitions that includes precision half-life measurements, and in the future, the determination of the Fermi Gamow-Teller mixing ratio, has started at the University of Notre Dame. This work is supported in part by the National Science Foundation.
A quasi-spectral method for Cauchy problem of 2/D Laplace equation on an annulus
NASA Astrophysics Data System (ADS)
Saito, Katsuyoshi; Nakada, Manabu; Iijima, Kentaro; Onishi, Kazuei
2005-01-01
Real numbers are usually represented in the computer as a finite number of digits hexa-decimal floating point numbers. Accordingly the numerical analysis is often suffered from rounding errors. The rounding errors particularly deteriorate the precision of numerical solution in inverse and ill-posed problems. We attempt to use a multi-precision arithmetic for reducing the rounding error evil. The use of the multi-precision arithmetic system is by the courtesy of Dr Fujiwara of Kyoto University. In this paper we try to show effectiveness of the multi-precision arithmetic by taking two typical examples; the Cauchy problem of the Laplace equation in two dimensions and the shape identification problem by inverse scattering in three dimensions. It is concluded from a few numerical examples that the multi-precision arithmetic works well on the resolution of those numerical solutions, as it is combined with the high order finite difference method for the Cauchy problem and with the eigenfunction expansion method for the inverse scattering problem.
Prospects for Precision Neutrino Cross Section Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Deborah A.
2016-01-28
The need for precision cross section measurements is more urgent now than ever before, given the central role neutrino oscillation measurements play in the field of particle physics. The definition of precision is something worth considering, however. In order to build the best model for an oscillation experiment, cross section measurements should span a broad range of energies, neutrino interaction channels, and target nuclei. Precision might better be defined not in the final uncertainty associated with any one measurement but rather with the breadth of measurements that are available to constrain models. Current experience shows that models are better constrainedmore » by 10 measurements across different processes and energies with 10% uncertainties than by one measurement of one process on one nucleus with a 1% uncertainty. This article describes the current status of and future prospects for the field of precision cross section measurements considering the metric of how many processes, energies, and nuclei have been studied.« less
Influence of Waveform Characteristics on LiDAR Ranging Accuracy and Precision
Yang, Bingwei; Xie, Xinhao; Li, Duan
2018-01-01
Time of flight (TOF) based light detection and ranging (LiDAR) is a technology for calculating distance between start/stop signals of time of flight. In lab-built LiDAR, two ranging systems for measuring flying time between start/stop signals include time-to-digital converter (TDC) that counts time between trigger signals and analog-to-digital converter (ADC) that processes the sampled start/stop pulses waveform for time estimation. We study the influence of waveform characteristics on range accuracy and precision of two kinds of ranging system. Comparing waveform based ranging (WR) with analog discrete return system based ranging (AR), a peak detection method (WR-PK) shows the best ranging performance because of less execution time, high ranging accuracy, and stable precision. Based on a novel statistic mathematical method maximal information coefficient (MIC), WR-PK precision has a high linear relationship with the received pulse width standard deviation. Thus keeping the received pulse width of measuring a constant distance as stable as possible can improve ranging precision. PMID:29642639
Nanophotonic Trapping for Precise Manipulation of Biomolecular Arrays
Soltani, Mohammad; Lin, Jun; Forties, Robert A.; Inman, James T.; Saraf, Summer N.; Fulbright, Robert M.; Lipson, Michal; Wang, Michelle D.
2014-01-01
Optical trapping is a powerful manipulation and measurement technique widely employed in the biological and materials sciences1–8. Miniaturizing optical trap instruments onto optofluidic platforms holds promise for high throughput lab-on-chip applications9–16. However, a persistent challenge with existing optofluidic devices has been controlled and precise manipulation of trapped particles. Here we report a new class of on-chip optical trapping devices. Using photonic interference functionalities, an array of stable, three-dimensional on-chip optical traps is formed at the antinodes of a standing-wave evanescent field on a nanophotonic waveguide. By employing the thermo-optic effect via integrated electric microheaters, the traps can be repositioned at high speed (~ 30 kHz) with nanometer precision. We demonstrate sorting and manipulation of individual DNA molecules. In conjunction with laminar flows and fluorescence, we also show precise control of the chemical environment of a sample with simultaneous monitoring. Such a controllable trapping device has the potential for high-throughput precision measurements on chip. PMID:24776649
Nanophotonic trapping for precise manipulation of biomolecular arrays.
Soltani, Mohammad; Lin, Jun; Forties, Robert A; Inman, James T; Saraf, Summer N; Fulbright, Robert M; Lipson, Michal; Wang, Michelle D
2014-06-01
Optical trapping is a powerful manipulation and measurement technique widely used in the biological and materials sciences. Miniaturizing optical trap instruments onto optofluidic platforms holds promise for high-throughput lab-on-a-chip applications. However, a persistent challenge with existing optofluidic devices has been achieving controlled and precise manipulation of trapped particles. Here, we report a new class of on-chip optical trapping devices. Using photonic interference functionalities, an array of stable, three-dimensional on-chip optical traps is formed at the antinodes of a standing-wave evanescent field on a nanophotonic waveguide. By employing the thermo-optic effect via integrated electric microheaters, the traps can be repositioned at high speed (∼30 kHz) with nanometre precision. We demonstrate sorting and manipulation of individual DNA molecules. In conjunction with laminar flows and fluorescence, we also show precise control of the chemical environment of a sample with simultaneous monitoring. Such a controllable trapping device has the potential to achieve high-throughput precision measurements on chip.
High-precision radius automatic measurement using laser differential confocal technology
NASA Astrophysics Data System (ADS)
Jiang, Hongwei; Zhao, Weiqian; Yang, Jiamiao; Guo, Yongkui; Xiao, Yang
2015-02-01
A high precision radius automatic measurement method using laser differential confocal technology is proposed. Based on the property of an axial intensity curve that the null point precisely corresponds to the focus of the objective and the bipolar property, the method uses the composite PID (proportional-integral-derivative) control to ensure the steady movement of the motor for process of quick-trigger scanning, and uses least-squares linear fitting to obtain the position of the cat-eye and confocal positions, then calculates the radius of curvature of lens. By setting the number of measure times, precision auto-repeat measurement of the radius of curvature is achieved. The experiment indicates that the method has the measurement accuracy of better than 2 ppm, and the measuring repeatability is better than 0.05 μm. In comparison with the existing manual-single measurement, this method has a high measurement precision, a strong environment anti-interference capability, a better measuring repeatability which is only tenth of former's.
Xie, Weizhen; Zhang, Weiwei
2017-09-01
Negative emotion sometimes enhances memory (higher accuracy and/or vividness, e.g., flashbulb memories). The present study investigates whether it is the qualitative (precision) or quantitative (the probability of successful retrieval) aspect of memory that drives these effects. In a visual long-term memory task, observers memorized colors (Experiment 1a) or orientations (Experiment 1b) of sequentially presented everyday objects under negative, neutral, or positive emotions induced with International Affective Picture System images. In a subsequent test phase, observers reconstructed objects' colors or orientations using the method of adjustment. We found that mnemonic precision was enhanced under the negative condition relative to the neutral and positive conditions. In contrast, the probability of successful retrieval was comparable across the emotion conditions. Furthermore, the boost in memory precision was associated with elevated subjective feelings of remembering (vividness and confidence) and metacognitive sensitivity in Experiment 2. Altogether, these findings suggest a novel precision-based account for emotional memories. Copyright © 2017 Elsevier B.V. All rights reserved.
Nanosecond time transfer via shuttle laser ranging experiment
NASA Technical Reports Server (NTRS)
Reinhardt, V. S.; Premo, D. A.; Fitzmaurice, M. W.; Wardrip, S. C.; Cervenka, P. O.
1978-01-01
A method is described to use a proposed shuttle laser ranging experiment to transfer time with nanosecond precision. All that need be added to the original experiment are low cost ground stations and an atomic clock on the shuttle. It is shown that global time transfer can be accomplished with 1 ns precision and transfer up to distances of 2000 km can be accomplished with better than 100 ps precision.
2017-10-07
polymerization to make linear polyethylenes with carboxylic acid groups at precise intervals along the polymer . Precise acid- containing polymers provide...acid polyethylene and the a polymerized ionic liquids based on cyclopropenium. The instrument is also be used to study polymer segmental dynamics...Advances in batteries, fuel cells, and permselective membranes are materials limited. New acid- and ion-containing polymers must be designed and
2007 Precision Strike Winter Roundtable - Precision Engagement - Strategic Context for the Long War
2007-02-01
but also to import Mercedes - Benzes , pricey cognacs and other luxury items to buy loyalty. Washington fears that North Korea could decide to use its...Cappuccio—Executive Vice President and General Manager, Advanced Development Programs & Strategic Planning, Lockheed Martin Company JOINT INNOVATION ... Innovative Minds Lockheed Martin Aeronautics Company Frank Cappuccio, February 1, 2007 Precision Strike Winter Roundtable “Long Range Strike Weapons” 2Lockheed
Alternative Solvents and Technologies for Precision Cleaning of Aerospace Components
NASA Technical Reports Server (NTRS)
Grandelli, Heather; Maloney, Phillip; DeVor, Robert; Hintze, Paul
2014-01-01
Precision cleaning solvents for aerospace components and oxygen fuel systems, including currently used Vertrel-MCA, have a negative environmental legacy, high global warming potential, and have polluted cleaning sites. Thus, alternative solvents and technologies are being investigated with the aim of achieving precision contamination levels of less than 1 mg/sq ft. The technologies being evaluated are ultrasonic bath cleaning, plasma cleaning and supercritical carbon dioxide cleaning.
Improved DORIS accuracy for precise orbit determination and geodesy
NASA Technical Reports Server (NTRS)
Willis, Pascal; Jayles, Christian; Tavernier, Gilles
2004-01-01
In 2001 and 2002, 3 more DORIS satellites were launched. Since then, all DORIS results have been significantly improved. For precise orbit determination, 20 cm are now available in real-time with DIODE and 1.5 to 2 cm in post-processing. For geodesy, 1 cm precision can now be achieved regularly every week, making now DORIS an active part of a Global Observing System for Geodesy through the IDS.
Precision Airdrop (Largage de precision)
2005-12-01
NAVIGATION TO A PRECISION AIRDROP OVERVIEW RTO-AG-300-V24 2 - 9 the point from various compass headings. As the tests are conducted, the resultant...rate. This approach avoids including a magnetic compass for the heading reference, which has difficulties due to local changes in the magnetic field...Scientifica della Difesa ROYAUME-UNI Via XX Settembre 123 Dstl Knowledge Services ESPAGNE 00187 Roma Information Centre, Building 247 SDG TECEN / DGAM
2015-01-01
Multiple-baseline detection of a geostationary satellite with the Navy Precision Optical Interferometer J. Thomas Armstronga, Ellyn K. Bainesa...observations of a geostationary satellite using the Navy Precision Optical Inter- ferometer (NPOI) during the glint season of March 2015. We succeeded in...the second night. These baseline lengths correspond to a resolution of ∼4 m at geostationary altitude. This is the first multiple-baseline
Beyond Precision: Issues of Morality and Decision Making in Minimizing Collateral Casualties
2003-04-28
possible contributions from moral judgment and decision making . As Fuller himself said, laws “can create the conditions essential for a rational ...BEYOND PRECISION: Issues of Morality and Decision Making in Minimizing Collateral Casualties Program in Arms Control, Disarmament, and...28 APR 2003 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Beyond Precision: Issues of Morality and Decision Making in
Precision Relative Positioning for Automated Aerial Refueling from a Stereo Imaging System
2015-03-01
PRECISION RELATIVE POSITIONING FOR AUTOMATED AERIAL REFUELING FROM A STEREO IMAGING SYSTEM THESIS Kyle P. Werner, 2Lt, USAF AFIT-ENG-MS-15-M-048...REFUELING FROM A STEREO IMAGING SYSTEM THESIS Presented to the Faculty Department of Electrical and Computer Engineering Graduate School of...RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENG-MS-15-M-048 PRECISION RELATIVE POSITIONING FOR AUTOMATED AERIAL REFUELING FROM A STEREO IMAGING SYSTEM THESIS
Attentional priority determines working memory precision.
Klyszejko, Zuzanna; Rahmati, Masih; Curtis, Clayton E
2014-12-01
Visual working memory is a system used to hold information actively in mind for a limited time. The number of items and the precision with which we can store information has limits that define its capacity. How much control do we have over the precision with which we store information when faced with these severe capacity limitations? Here, we tested the hypothesis that rank-ordered attentional priority determines the precision of multiple working memory representations. We conducted two psychophysical experiments that manipulated the priority of multiple items in a two-alternative forced choice task (2AFC) with distance discrimination. In Experiment 1, we varied the probabilities with which memorized items were likely to be tested. To generalize the effects of priority beyond simple cueing, in Experiment 2, we manipulated priority by varying monetary incentives contingent upon successful memory for items tested. Moreover, we illustrate our hypothesis using a simple model that distributed attentional resources across items with rank-ordered priorities. Indeed, we found evidence in both experiments that priority affects the precision of working memory in a monotonic fashion. Our results demonstrate that representations of priority may provide a mechanism by which resources can be allocated to increase the precision with which we encode and briefly store information. Copyright © 2014 Elsevier Ltd. All rights reserved.
Neural control and precision of flight muscle activation in Drosophila.
Lehmann, Fritz-Olaf; Bartussek, Jan
2017-01-01
Precision of motor commands is highly relevant in a large context of various locomotor behaviors, including stabilization of body posture, heading control and directed escape responses. While posture stability and heading control in walking and swimming animals benefit from high friction via ground reaction forces and elevated viscosity of water, respectively, flying animals have to cope with comparatively little aerodynamic friction on body and wings. Although low frictional damping in flight is the key to the extraordinary aerial performance and agility of flying birds, bats and insects, it challenges these animals with extraordinary demands on sensory integration and motor precision. Our review focuses on the dynamic precision with which Drosophila activates its flight muscular system during maneuvering flight, considering relevant studies on neural and muscular mechanisms of thoracic propulsion. In particular, we tackle the precision with which flies adjust power output of asynchronous power muscles and synchronous flight control muscles by monitoring muscle calcium and spike timing within the stroke cycle. A substantial proportion of the review is engaged in the significance of visual and proprioceptive feedback loops for wing motion control including sensory integration at the cellular level. We highlight that sensory feedback is the basis for precise heading control and body stability in flies.
NASA Astrophysics Data System (ADS)
Hishikawa, Yoshihiro; Doi, Takuya; Higa, Michiya; Ohshima, Hironori; Takenouchi, Takakazu; Yamagoe, Kengo
2017-08-01
Precise outdoor measurement of the current-voltage (I-V) curves of photovoltaic (PV) modules is desired for many applications such as low-cost onsite performance measurement, monitoring, and diagnosis. Conventional outdoor measurement technologies have a problem in that their precision is low when the solar irradiance is unstable, hence, limiting the opportunity of precise measurement only on clear sunny days. The purpose of this study is to investigate an outdoor measurement procedure, that can improve both the measurement opportunity and precision. Fast I-V curve measurements within 0.2 s and synchronous measurement of irradiance using a PV module irradiance sensor very effectively improved the precision. A small standard deviation (σ) of the module’s maximum output power (P max) in the range of 0.7-0.9% is demonstrated, based on the basis of a 6 month experiment, that mainly includes partly sunny days and cloudy days, during which the solar irradiance is unstable. The σ was further improved to 0.3-0.5% by correcting the curves for the small variation of irradiance. This indicates that the procedure of this study enables much more reproducible I-V curve measurements than a conventional usual procedure under various climatic conditions. Factors that affect measurement results are discussed, to further improve the precision.
Video-rate or high-precision: a flexible range imaging camera
NASA Astrophysics Data System (ADS)
Dorrington, Adrian A.; Cree, Michael J.; Carnegie, Dale A.; Payne, Andrew D.; Conroy, Richard M.; Godbaz, John P.; Jongenelen, Adrian P. P.
2008-02-01
A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system's frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection.
Linder, Suzanne K; Kamath, Geetanjali R; Pratt, Gregory F; Saraykar, Smita S; Volk, Robert J
2015-04-01
To compare the effectiveness of two search methods in identifying studies that used the Control Preferences Scale (CPS), a health care decision-making instrument commonly used in clinical settings. We searched the literature using two methods: (1) keyword searching using variations of "Control Preferences Scale" and (2) cited reference searching using two seminal CPS publications. We searched three bibliographic databases [PubMed, Scopus, and Web of Science (WOS)] and one full-text database (Google Scholar). We report precision and sensitivity as measures of effectiveness. Keyword searches in bibliographic databases yielded high average precision (90%) but low average sensitivity (16%). PubMed was the most precise, followed closely by Scopus and WOS. The Google Scholar keyword search had low precision (54%) but provided the highest sensitivity (70%). Cited reference searches in all databases yielded moderate sensitivity (45-54%), but precision ranged from 35% to 75% with Scopus being the most precise. Cited reference searches were more sensitive than keyword searches, making it a more comprehensive strategy to identify all studies that use a particular instrument. Keyword searches provide a quick way of finding some but not all relevant articles. Goals, time, and resources should dictate the combination of which methods and databases are used. Copyright © 2015 Elsevier Inc. All rights reserved.
Linder, Suzanne K.; Kamath, Geetanjali R.; Pratt, Gregory F.; Saraykar, Smita S.; Volk, Robert J.
2015-01-01
Objective To compare the effectiveness of two search methods in identifying studies that used the Control Preferences Scale (CPS), a healthcare decision-making instrument commonly used in clinical settings. Study Design & Setting We searched the literature using two methods: 1) keyword searching using variations of “control preferences scale” and 2) cited reference searching using two seminal CPS publications. We searched three bibliographic databases [PubMed, Scopus, Web of Science (WOS)] and one full-text database (Google Scholar). We report precision and sensitivity as measures of effectiveness. Results Keyword searches in bibliographic databases yielded high average precision (90%), but low average sensitivity (16%). PubMed was the most precise, followed closely by Scopus and WOS. The Google Scholar keyword search had low precision (54%) but provided the highest sensitivity (70%). Cited reference searches in all databases yielded moderate sensitivity (45–54%), but precision ranged from 35–75% with Scopus being the most precise. Conclusion Cited reference searches were more sensitive than keyword searches, making it a more comprehensive strategy to identify all studies that use a particular instrument. Keyword searches provide a quick way of finding some but not all relevant articles. Goals, time and resources should dictate the combination of which methods and databases are used. PMID:25554521
The prospects of pulsar timing with new-generation radio telescopes and the Square Kilometre Array
NASA Astrophysics Data System (ADS)
Stappers, B. W.; Keane, E. F.; Kramer, M.; Possenti, A.; Stairs, I. H.
2018-05-01
Pulsars are highly magnetized and rapidly rotating neutron stars. As they spin, the lighthouse-like beam of radio emission from their magnetic poles sweeps across the Earth with a regularity approaching that of the most precise clocks known. This precision combined with the extreme environments in which they are found, often in compact orbits with other neutron stars and white dwarfs, makes them excellent tools for studying gravity. Present and near-future pulsar surveys, especially those using the new generation of telescopes, will find more extreme binary systems and pulsars that are more precise `clocks'. These telescopes will also greatly improve the precision to which we can measure the arrival times of the pulses. The Square Kilometre Array will revolutionize pulsar searches and timing precision. The increased number of sources will reveal rare sources, including possibly a pulsar-black hole binary, which can provide the most stringent tests of strong-field gravity. The improved timing precision will reveal new phenomena and also allow us to make a detection of gravitational waves in the nanohertz frequency regime. It is here where we expect to see the signature of the binary black holes that are formed as galaxies merge throughout cosmological history. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.
Genetic Mutations and Epigenetic Modifications: Driving Cancer and Informing Precision Medicine
Coyle, Krysta Mila; Boudreau, Jeanette E.
2017-01-01
Cancer treatment is undergoing a significant revolution from “one-size-fits-all” cytotoxic therapies to tailored approaches that precisely target molecular alterations. Precision strategies for drug development and patient stratification, based on the molecular features of tumors, are the next logical step in a long history of approaches to cancer therapy. In this review, we discuss the history of cancer treatment from generic natural extracts and radical surgical procedures to site-specific and combinatorial treatment regimens, which have incrementally improved patient outcomes. We discuss the related contributions of genetics and epigenetics to cancer progression and the response to targeted therapies and identify challenges and opportunities for the success of precision medicine. The identification of patients who will benefit from targeted therapies is more complex than simply identifying patients whose tumors harbour the targeted aberration, and intratumoral heterogeneity makes it difficult to determine if a precision therapy is successful during treatment. This heterogeneity enables tumors to develop resistance to targeted approaches; therefore, the rational combination of therapeutic agents will limit the threat of acquired resistance to therapeutic success. By incorporating the view of malignant transformation modulated by networks of genetic and epigenetic interactions, molecular strategies will enable precision medicine for effective treatment across cancer subtypes. PMID:28685150
An Assessment of Imaging Informatics for Precision Medicine in Cancer.
Chennubhotla, C; Clarke, L P; Fedorov, A; Foran, D; Harris, G; Helton, E; Nordstrom, R; Prior, F; Rubin, D; Saltz, J H; Shalley, E; Sharma, A
2017-08-01
Objectives: Precision medicine requires the measurement, quantification, and cataloging of medical characteristics to identify the most effective medical intervention. However, the amount of available data exceeds our current capacity to extract meaningful information. We examine the informatics needs to achieve precision medicine from the perspective of quantitative imaging and oncology. Methods: The National Cancer Institute (NCI) organized several workshops on the topic of medical imaging and precision medicine. The observations and recommendations are summarized herein. Results: Recommendations include: use of standards in data collection and clinical correlates to promote interoperability; data sharing and validation of imaging tools; clinician's feedback in all phases of research and development; use of open-source architecture to encourage reproducibility and reusability; use of challenges which simulate real-world situations to incentivize innovation; partnership with industry to facilitate commercialization; and education in academic communities regarding the challenges involved with translation of technology from the research domain to clinical utility and the benefits of doing so. Conclusions: This article provides a survey of the role and priorities for imaging informatics to help advance quantitative imaging in the era of precision medicine. While these recommendations were drawn from oncology, they are relevant and applicable to other clinical domains where imaging aids precision medicine. Georg Thieme Verlag KG Stuttgart.
Toward Precision Healthcare: Context and Mathematical Challenges
Colijn, Caroline; Jones, Nick; Johnston, Iain G.; Yaliraki, Sophia; Barahona, Mauricio
2017-01-01
Precision medicine refers to the idea of delivering the right treatment to the right patient at the right time, usually with a focus on a data-centered approach to this task. In this perspective piece, we use the term “precision healthcare” to describe the development of precision approaches that bridge from the individual to the population, taking advantage of individual-level data, but also taking the social context into account. These problems give rise to a broad spectrum of technical, scientific, policy, ethical and social challenges, and new mathematical techniques will be required to meet them. To ensure that the science underpinning “precision” is robust, interpretable and well-suited to meet the policy, ethical and social questions that such approaches raise, the mathematical methods for data analysis should be transparent, robust, and able to adapt to errors and uncertainties. In particular, precision methodologies should capture the complexity of data, yet produce tractable descriptions at the relevant resolution while preserving intelligibility and traceability, so that they can be used by practitioners to aid decision-making. Through several case studies in this domain of precision healthcare, we argue that this vision requires the development of new mathematical frameworks, both in modeling and in data analysis and interpretation. PMID:28377724
Nanomaterials for Cancer Precision Medicine.
Wang, Yilong; Sun, Shuyang; Zhang, Zhiyuan; Shi, Donglu
2018-04-01
Medical science has recently advanced to the point where diagnosis and therapeutics can be carried out with high precision, even at the molecular level. A new field of "precision medicine" has consequently emerged with specific clinical implications and challenges that can be well-addressed by newly developed nanomaterials. Here, a nanoscience approach to precision medicine is provided, with a focus on cancer therapy, based on a new concept of "molecularly-defined cancers." "Next-generation sequencing" is introduced to identify the oncogene that is responsible for a class of cancers. This new approach is fundamentally different from all conventional cancer therapies that rely on diagnosis of the anatomic origins where the tumors are found. To treat cancers at molecular level, a recently developed "microRNA replacement therapy" is applied, utilizing nanocarriers, in order to regulate the driver oncogene, which is the core of cancer precision therapeutics. Furthermore, the outcome of the nanomediated oncogenic regulation has to be accurately assessed by the genetically characterized, patient-derived xenograft models. Cancer therapy in this fashion is a quintessential example of precision medicine, presenting many challenges to the materials communities with new issues in structural design, surface functionalization, gene/drug storage and delivery, cell targeting, and medical imaging. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Toward the use of precision medicine for the treatment of head and neck squamous cell carcinoma.
Gong, Wang; Xiao, Yandi; Wei, Zihao; Yuan, Yao; Qiu, Min; Sun, Chongkui; Zeng, Xin; Liang, Xinhua; Feng, Mingye; Chen, Qianming
2017-01-10
Precision medicine is a new strategy that aims at preventing and treating human diseases by focusing on individual variations in people's genes, environment and lifestyle. Precision medicine has been used for cancer diagnosis and treatment and shows evident clinical efficacy. Rapid developments in molecular biology, genetics and sequencing technologies, as well as computational technology, has enabled the establishment of "big data", such as the Human Genome Project, which provides a basis for precision medicine. Head and neck squamous cell carcinoma (HNSCC) is an aggressive cancer with a high incidence rate and low survival rate. Current therapies are often aggressive and carry considerable side effects. Much research now indicates that precision medicine can be used for HNSCC and may achieve improved results. From this perspective, we present an overview of the current status, potential strategies, and challenges of precision medicine in HNSCC. We focus on targeted therapy based on cell the surface signaling receptors epidermal growth factor receptor (EGFR), vascular endothelial growth factor (VEGF) and human epidermal growth factor receptor-2 (HER2), and on the PI3K/AKT/mTOR, JAK/STAT3 and RAS/RAF/MEK/ERK cellular signaling pathways. Gene therapy for the treatment of HNSCC is also discussed.
Toward precision medicine and health: Opportunities and challenges in allergic diseases.
Galli, Stephen Joseph
2016-05-01
Precision medicine (also called personalized, stratified, or P4 medicine) can be defined as the tailoring of preventive measures and medical treatments to the characteristics of each patient to obtain the best clinical outcome for each person while ideally also enhancing the cost-effectiveness of such interventions for patients and society. Clearly, the best clinical outcome for allergic diseases is not to get them in the first place. To emphasize the importance of disease prevention, a critical component of precision medicine can be referred to as precision health, which is defined herein as the use of all available information pertaining to specific subjects (including family history, individual genetic and other biometric information, and exposures to risk factors for developing or exacerbating disease), as well as features of their environments, to sustain and enhance health and prevent the development of disease. In this article I will provide a personal perspective on how the precision health-precision medicine approach can be applied to the related goals of preventing the development of allergic disorders and providing the most effective diagnosis, disease monitoring, and care for those with these prevalent diseases. I will also mention some of the existing and potential challenges to achieving these ambitious goals. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Toward the use of precision medicine for the treatment of head and neck squamous cell carcinoma
Gong, Wang; Xiao, Yandi; Wei, Zihao; Yuan, Yao; Qiu, Min; Sun, Chongkui; Zeng, Xin; Liang, Xinhua; Feng, Mingye; Chen, Qianming
2017-01-01
Precision medicine is a new strategy that aims at preventing and treating human diseases by focusing on individual variations in people's genes, environment and lifestyle. Precision medicine has been used for cancer diagnosis and treatment and shows evident clinical efficacy. Rapid developments in molecular biology, genetics and sequencing technologies, as well as computational technology, has enabled the establishment of “big data”, such as the Human Genome Project, which provides a basis for precision medicine. Head and neck squamous cell carcinoma (HNSCC) is an aggressive cancer with a high incidence rate and low survival rate. Current therapies are often aggressive and carry considerable side effects. Much research now indicates that precision medicine can be used for HNSCC and may achieve improved results. From this perspective, we present an overview of the current status, potential strategies, and challenges of precision medicine in HNSCC. We focus on targeted therapy based on cell the surface signaling receptors epidermal growth factor receptor (EGFR), vascular endothelial growth factor (VEGF) and human epidermal growth factor receptor-2 (HER2), and on the PI3K/AKT/mTOR, JAK/STAT3 and RAS/RAF/MEK/ERK cellular signaling pathways. Gene therapy for the treatment of HNSCC is also discussed. PMID:27924064
Capacity and precision in an animal model of visual short-term memory
Lara, Antonio H.; Wallis, Jonathan D.
2013-01-01
Temporary storage of information in visual short-term memory (VSTM) is a key component of many complex cognitive abilities. However, it is highly limited in capacity. Understanding the neurophysiological nature of this capacity limit will require a valid animal model of VSTM. We used a multiple-item color change detection task to measure macaque monkeys’ VSTM capacity. Subjects’ performance deteriorated and reaction times increased as a function of the number of items in memory. Additionally, we measured the precision of the memory representations by varying the distance between sample and test colors. In trials with similar sample and test colors, subjects made more errors compared to trials with highly discriminable colors. We modeled the error distribution as a Gaussian function and used this to estimate the precision of VSTM representations. We found that as the number of items in memory increases the precision of the representations decreases dramatically. Additionally, we found that focusing attention on one of the objects increases the precision with which that object is stored and degrading the precision of the remaining. These results are in line with recent findings in human psychophysics and provide a solid foundation for understanding the neurophysiological nature of the capacity limit of VSTM. PMID:22419756
Eckstein, Felix; Kunz, Manuela; Hudelmaier, Martin; Jackson, Rebecca; Yu, Joseph; Eaton, Charles B; Schneider, Erika
2007-02-01
Phased-array (PA) coils generally provide higher signal-to-noise ratios (SNRs) than quadrature knee coils. In this pilot study for the Osteoarthritis Initiative (OAI) we compared these two types of coils in terms of contrast-to-noise ratio (CNR), precision, and consistency of quantitative femorotibial cartilage measurements. Test-retest measurements were acquired using coronal fast low-angle shot with water excitation (FLASHwe) and coronal multiplanar reconstruction (MPR) of sagittal double-echo steady state with water excitation (DESSwe) at 3T. The precision errors for cartilage volume and thickness were
Precision measurements on trapped antihydrogen in the ALPHA experiment.
Eriksson, S
2018-03-28
Both the 1S-2S transition and the ground state hyperfine spectrum have been observed in trapped antihydrogen. The former constitutes the first observation of resonant interaction of light with an anti-atom, and the latter is the first detailed measurement of a spectral feature in antihydrogen. Owing to the narrow intrinsic linewidth of the 1S-2S transition and use of two-photon laser excitation, the transition energy can be precisely determined in both hydrogen and antihydrogen, allowing a direct comparison as a test of fundamental symmetry. The result is consistent with CPT invariance at a relative precision of around 2×10 -10 This constitutes the most precise measurement of a property of antihydrogen. The hyperfine spectrum of antihydrogen is determined to a relative uncertainty of 4×10 -4 The excited state and the hyperfine spectroscopy techniques currently both show sensitivity at the few 100 kHz level on the absolute scale. Here, the most recent work of the ALPHA collaboration on precision spectroscopy of antihydrogen is presented together with an outlook on improving the precision of measurements involving lasers and microwave radiation. Prospects of measuring the Lamb shift and determining the antiproton charge radius in trapped antihydrogen in the ALPHA apparatus are presented. Future perspectives of precision measurements of trapped antihydrogen in the ALPHA apparatus when the ELENA facility becomes available to experiments at CERN are discussed.This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'. © 2018 The Author(s).
Shahbi, M; Rajabpour, A
2017-08-01
Phthorimaea operculella Zeller is an important pest of potato in Iran. Spatial distribution and fixed-precision sequential sampling for population estimation of the pest on two potato cultivars, Arinda ® and Sante ® , were studied in two separate potato fields during two growing seasons (2013-2014 and 2014-2015). Spatial distribution was investigated by Taylor's power law and Iwao's patchiness. Results showed that the spatial distribution of eggs and larvae was random. In contrast to Iwao's patchiness, Taylor's power law provided a highly significant relationship between variance and mean density. Therefore, fixed-precision sequential sampling plan was developed by Green's model at two precision levels of 0.25 and 0.1. The optimum sample size on Arinda ® and Sante ® cultivars at precision level of 0.25 ranged from 151 to 813 and 149 to 802 leaves, respectively. At 0.1 precision level, the sample sizes varied from 5083 to 1054 and 5100 to 1050 leaves for Arinda ® and Sante ® cultivars, respectively. Therefore, the optimum sample sizes for the cultivars, with different resistance levels, were not significantly different. According to the calculated stop lines, the sampling must be continued until cumulative number of eggs + larvae reached to 15-16 or 96-101 individuals at precision levels of 0.25 or 0.1, respectively. The performance of the sampling plan was validated by resampling analysis using resampling for validation of sampling plans software. The sampling plant provided in this study can be used to obtain a rapid estimate of the pest density with minimal effort.
Boahen, Kwabena
2013-01-01
A fundamental question in neuroscience is how neurons perform precise operations despite inherent variability. This question also applies to neuromorphic engineering, where low-power microchips emulate the brain using large populations of diverse silicon neurons. Biological neurons in the auditory pathway display precise spike timing, critical for sound localization and interpretation of complex waveforms such as speech, even though they are a heterogeneous population. Silicon neurons are also heterogeneous, due to a key design constraint in neuromorphic engineering: smaller transistors offer lower power consumption and more neurons per unit area of silicon, but also more variability between transistors and thus between silicon neurons. Utilizing this variability in a neuromorphic model of the auditory brain stem with 1,080 silicon neurons, we found that a low-voltage-activated potassium conductance (gKL) enables precise spike timing via two mechanisms: statically reducing the resting membrane time constant and dynamically suppressing late synaptic inputs. The relative contribution of these two mechanisms is unknown because blocking gKL in vitro eliminates dynamic adaptation but also lengthens the membrane time constant. We replaced gKL with a static leak in silico to recover the short membrane time constant and found that silicon neurons could mimic the spike-time precision of their biological counterparts, but only over a narrow range of stimulus intensities and biophysical parameters. The dynamics of gKL were required for precise spike timing robust to stimulus variation across a heterogeneous population of silicon neurons, thus explaining how neural and neuromorphic systems may perform precise operations despite inherent variability. PMID:23554436
Huang, Yang; Lowe, Henry J.; Hersh, William R.
2003-01-01
Objective: Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. Design: A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. Measurements: The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. Results: While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. Conclusion: In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports. PMID:12925544
Huang, Yang; Lowe, Henry J; Hersh, William R
2003-01-01
Despite the advantages of structured data entry, much of the patient record is still stored as unstructured or semistructured narrative text. The issue of representing clinical document content remains problematic. The authors' prior work using an automated UMLS document indexing system has been encouraging but has been affected by the generally low indexing precision of such systems. In an effort to improve precision, the authors have developed a context-sensitive document indexing model to calculate the optimal subset of UMLS source vocabularies used to index each document section. This pilot study was performed to evaluate the utility of this indexing approach on a set of clinical radiology reports. A set of clinical radiology reports that had been indexed manually using UMLS concept descriptors was indexed automatically by the SAPHIRE indexing engine. Using the data generated by this process the authors developed a system that simulated indexing, at the document section level, of the same document set using many permutations of a subset of the UMLS constituent vocabularies. The precision and recall scores generated by simulated indexing for each permutation of two or three UMLS constituent vocabularies were determined. While there was considerable variation in precision and recall values across the different subtypes of radiology reports, the overall effect of this indexing strategy using the best combination of two or three UMLS constituent vocabularies was an improvement in precision without significant impact of recall. In this pilot study a contextual indexing strategy improved overall precision in a set of clinical radiology reports.
What Is Trust? Ethics and Risk Governance in Precision Medicine and Predictive Analytics
Adjekum, Afua; Ienca, Marcello
2017-01-01
Abstract Trust is a ubiquitous term used in emerging technology (e.g., Big Data, precision medicine), innovation policy, and governance literatures in particular. But what exactly is trust? Even though trust is considered a critical requirement for the successful deployment of precision medicine initiatives, nonetheless, there is a need for further conceptualization with regard to what qualifies as trust, and what factors might establish and sustain trust in precision medicine, predictive analytics, and large-scale biology. These new fields of 21st century medicine and health often deal with the “futures” and hence, trust gains a temporal and ever-present quality for both the present and the futures anticipated by new technologies and predictive analytics. We address these conceptual gaps that have important practical implications in the way we govern risk and unknowns associated with emerging technologies in biology, medicine, and health broadly. We provide an in-depth conceptual analysis and an operative definition of trust dynamics in precision medicine. In addition, we identify three main types of “trust facilitators”: (1) technical, (2) ethical, and (3) institutional. This three-dimensional framework on trust is necessary to building and maintaining trust in 21st century knowledge-based innovations that governments and publics invest for progressive societal change, development, and sustainable prosperity. Importantly, we analyze, identify, and deliberate on the dimensions of precision medicine and large-scale biology that have carved out trust as a pertinent tool to its success. Moving forward, we propose a “points to consider” on how best to enhance trust in precision medicine and predictive analytics. PMID:29257733
Alessandrini, Marco; Chaudhry, Mamoonah; Dodgen, Tyren M; Pepper, Michael S
2016-10-01
In a move indicative of the enthusiastic support of precision medicine, the U.S. President Barack Obama announced the Precision Medicine Initiative in January 2015. The global precision medicine ecosystem is, thus, receiving generous support from the United States ($215 million), and numerous other governments have followed suit. In the context of precision medicine, drug treatment and prediction of its outcomes have been important for nearly six decades in the field of pharmacogenomics. The field offers an elegant solution for minimizing the effects and occurrence of adverse drug reactions (ADRs). The Clinical Pharmacogenetics Implementation Consortium (CPIC) plays an important role in this context, and it aims at specifically guiding the translation of clinically relevant and evidence-based pharmacogenomics research. In this forward-looking analysis, we make particular reference to several of the CPIC guidelines and their role in guiding the treatment of highly relevant diseases, namely cardiovascular disease, major depressive disorder, cancer, and human immunodeficiency virus, with a view to predicting and managing ADRs. In addition, we provide a list of the top 10 crosscutting opportunities and challenges facing the fields of precision medicine and pharmacogenomics, which have broad applicability independent of the drug class involved. Many of these opportunities and challenges pertain to infrastructure, study design, policy, and science culture in the early 21st century. Ultimately, rational pharmacogenomics study design and the acquisition of comprehensive phenotypic data that proportionately match the genomics data should be an imperative as we move forward toward global precision medicine.
Alessandrini, Marco; Chaudhry, Mamoonah; Dodgen, Tyren M.
2016-01-01
Abstract In a move indicative of the enthusiastic support of precision medicine, the U.S. President Barack Obama announced the Precision Medicine Initiative in January 2015. The global precision medicine ecosystem is, thus, receiving generous support from the United States ($215 million), and numerous other governments have followed suit. In the context of precision medicine, drug treatment and prediction of its outcomes have been important for nearly six decades in the field of pharmacogenomics. The field offers an elegant solution for minimizing the effects and occurrence of adverse drug reactions (ADRs). The Clinical Pharmacogenetics Implementation Consortium (CPIC) plays an important role in this context, and it aims at specifically guiding the translation of clinically relevant and evidence-based pharmacogenomics research. In this forward-looking analysis, we make particular reference to several of the CPIC guidelines and their role in guiding the treatment of highly relevant diseases, namely cardiovascular disease, major depressive disorder, cancer, and human immunodeficiency virus, with a view to predicting and managing ADRs. In addition, we provide a list of the top 10 crosscutting opportunities and challenges facing the fields of precision medicine and pharmacogenomics, which have broad applicability independent of the drug class involved. Many of these opportunities and challenges pertain to infrastructure, study design, policy, and science culture in the early 21st century. Ultimately, rational pharmacogenomics study design and the acquisition of comprehensive phenotypic data that proportionately match the genomics data should be an imperative as we move forward toward global precision medicine. PMID:27643672
NASA Astrophysics Data System (ADS)
Tugores, M. Pilar; Iglesias, Magdalena; Oñate, Dolores; Miquel, Joan
2016-02-01
In the Mediterranean Sea, the European anchovy (Engraulis encrasicolus) displays a key role in ecological and economical terms. Ensuring stock sustainability requires the provision of crucial information, such as species spatial distribution or unbiased abundance and precision estimates, so that management strategies can be defined (e.g. fishing quotas, temporal closure areas or marine protected areas MPA). Furthermore, the estimation of the precision of global abundance at different sampling intensities can be used for survey design optimisation. Geostatistics provide a priori unbiased estimations of the spatial structure, global abundance and precision for autocorrelated data. However, their application to non-Gaussian data introduces difficulties in the analysis in conjunction with low robustness or unbiasedness. The present study applied intrinsic geostatistics in two dimensions in order to (i) analyse the spatial distribution of anchovy in Spanish Western Mediterranean waters during the species' recruitment season, (ii) produce distribution maps, (iii) estimate global abundance and its precision, (iv) analyse the effect of changing the sampling intensity on the precision of global abundance estimates and, (v) evaluate the effects of several methodological options on the robustness of all the analysed parameters. The results suggested that while the spatial structure was usually non-robust to the tested methodological options when working with the original dataset, it became more robust for the transformed datasets (especially for the log-backtransformed dataset). The global abundance was always highly robust and the global precision was highly or moderately robust to most of the methodological options, except for data transformation.
Debats, Nienke B.; Kingma, Idsart; Beek, Peter J.; Smeets, Jeroen B. J.
2012-01-01
How does the magnitude of the exploration force influence the precision of haptic perceptual estimates? To address this question, we examined the perceptual precision for moment of inertia (i.e., an object's “angular mass”) under different force conditions, using the Weber fraction to quantify perceptual precision. Participants rotated a rod around a fixed axis and judged its moment of inertia in a two-alternative forced-choice task. We instructed different levels of exploration force, thereby manipulating the magnitude of both the exploration force and the angular acceleration. These are the two signals that are needed by the nervous system to estimate moment of inertia. Importantly, one can assume that the absolute noise on both signals increases with an increase in the signals' magnitudes, while the relative noise (i.e., noise/signal) decreases with an increase in signal magnitude. We examined how the perceptual precision for moment of inertia was affected by this neural noise. In a first experiment we found that a low exploration force caused a higher Weber fraction (22%) than a high exploration force (13%), which suggested that the perceptual precision was constrained by the relative noise. This hypothesis was supported by the result of a second experiment, in which we found that the relationship between exploration force and Weber fraction had a similar shape as the theoretical relationship between signal magnitude and relative noise. The present study thus demonstrated that the amount of force used to explore an object can profoundly influence the precision by which its properties are perceived. PMID:23028437
What Is Trust? Ethics and Risk Governance in Precision Medicine and Predictive Analytics.
Adjekum, Afua; Ienca, Marcello; Vayena, Effy
2017-12-01
Trust is a ubiquitous term used in emerging technology (e.g., Big Data, precision medicine), innovation policy, and governance literatures in particular. But what exactly is trust? Even though trust is considered a critical requirement for the successful deployment of precision medicine initiatives, nonetheless, there is a need for further conceptualization with regard to what qualifies as trust, and what factors might establish and sustain trust in precision medicine, predictive analytics, and large-scale biology. These new fields of 21st century medicine and health often deal with the "futures" and hence, trust gains a temporal and ever-present quality for both the present and the futures anticipated by new technologies and predictive analytics. We address these conceptual gaps that have important practical implications in the way we govern risk and unknowns associated with emerging technologies in biology, medicine, and health broadly. We provide an in-depth conceptual analysis and an operative definition of trust dynamics in precision medicine. In addition, we identify three main types of "trust facilitators": (1) technical, (2) ethical, and (3) institutional. This three-dimensional framework on trust is necessary to building and maintaining trust in 21st century knowledge-based innovations that governments and publics invest for progressive societal change, development, and sustainable prosperity. Importantly, we analyze, identify, and deliberate on the dimensions of precision medicine and large-scale biology that have carved out trust as a pertinent tool to its success. Moving forward, we propose a "points to consider" on how best to enhance trust in precision medicine and predictive analytics.
Blasimme, Alessandro; Vayena, Effy
2016-11-04
Precision medicine promises to develop diagnoses and treatments that take individual variability into account. According to most specialists, turning this promise into reality will require adapting the established framework of clinical research ethics, and paying more attention to participants' attitudes towards sharing genotypic, phenotypic, lifestyle data and health records, and ultimately to their desire to be engaged as active partners in medical research.Notions such as participation, engagement and partnership have been introduced in bioethics debates concerning genetics and large-scale biobanking to broaden the focus of discussion beyond individual choice and individuals' moral interests. The uptake of those concepts in precision medicine is to be welcomed. However, as data and medical information from research participants in precision medicine cohorts will be collected on an individual basis, translating a participatory approach in this emerging area may prove cumbersome. Therefore, drawing on Joseph Raz's perfectionism, we propose a principle of respect for autonomous agents that, we reckon, can address many of the concerns driving recent scholarship on partnership and public participation, while avoiding some of the limitations these concept have in the context of precision medicine. Our approach offers a normative clarification to how becoming partners in precision is compatible with retaining autonomy.Realigning the value of autonomy with ideals of direct engagement, we show, can provide adequate normative orientation to precision medicine; it can do justice to the idea of moral pluralism by stressing the value of moral self-determination: and, finally, it can reconcile the notion of autonomy with other more communitarian values such as participation and solidarity.
High-precision half-life measurements of the T =1 /2 mirror β decays 17F and 33Cl
NASA Astrophysics Data System (ADS)
Grinyer, J.; Grinyer, G. F.; Babo, M.; Bouzomita, H.; Chauveau, P.; Delahaye, P.; Dubois, M.; Frigot, R.; Jardin, P.; Leboucher, C.; Maunoury, L.; Seiffert, C.; Thomas, J. C.; Traykov, E.
2015-10-01
Background: Measurements of the f t values for T =1 /2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the f t values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T =1 /2 β+ emitters, 17F and 33Cl, in order to eliminate the half-life as the leading source of uncertainty in their f t values. Method: Half-lives of 17F and 33Cl were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The 17F half-life result, 64.347 (35) s, precise to ±0.05 % , is a factor of 5 times more precise than the previous world average. The half-life of 33Cl was determined to be 2.5038 (22) s. The current precision of ±0.09 % is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the f t values for both T =1 /2 mirror decays 17F and 33Cl.
Evaluation of the EGNOS service for topographic profiling in field geosciences
NASA Astrophysics Data System (ADS)
Kromuszczyńska, Olga; Mège, Daniel; Castaldo, Luigi; Gurgurewicz, Joanna; Makowska, Magdalena; Dębniak, Krzysztof; Jelínek, Róbert
2016-09-01
Consumer grade Global Positioning System (GPS) receivers are commonly used as a tool for data collection in many fields, including geosciences. One of the methods for improving the GPS signal is provided by the Wide Area Differential GPS (WADGPS), which uses geostationary satellites to correct errors affecting the signal in real time. This study presents results of three experiments aiming at determining whether the precision of field measurements made by such a receiver (Garmin GPSMAP 62s) operating in either the non-differential and the WADGPS differential mode is suitable for characterizing geomorphological objects or landforms. It assumes in a typical field work situation, when time cannot be devoted in the field to long periods of stationary GPS measurements and the precision of topographic profile is at least as important as, if not more than, positioning of individual points. The results show that with maintaining some rules, the expected precision may meet the nominal precision. The repeatability (coherence) of topographic profiles conducted at low speed (0.5 m s- 1) in mountain terrain is good, and vertical precision is improved in the WADGPS mode. Horizontal precision is equivalent in both modes. The GPS receiver should be operating at least 30 min prior to measuring and should not be turned off between measurements that the user like to compare. If the GPS receiver needs to be reset between profiles to be compared, the measurement precision is higher in the non-differential GPS mode. Following these rules may result in improvement of measurement quality by 20% to 80%.
Examining Exposure Assessment in Shift Work Research: A Study on Depression Among Nurses.
Hall, Amy L; Franche, Renée-Louise; Koehoorn, Mieke
2018-02-13
Coarse exposure assessment and assignment is a common issue facing epidemiological studies of shift work. Such measures ignore a number of exposure characteristics that may impact on health, increasing the likelihood of biased effect estimates and masked exposure-response relationships. To demonstrate the impacts of exposure assessment precision in shift work research, this study investigated relationships between work schedule and depression in a large survey of Canadian nurses. The Canadian 2005 National Survey of the Work and Health of Nurses provided the analytic sample (n = 11450). Relationships between work schedule and depression were assessed using logistic regression models with high, moderate, and low-precision exposure groupings. The high-precision grouping described shift timing and rotation frequency, the moderate-precision grouping described shift timing, and the low-precision grouping described the presence/absence of shift work. Final model estimates were adjusted for the potential confounding effects of demographic and work variables, and bootstrap weights were used to generate sampling variances that accounted for the survey sample design. The high-precision exposure grouping model showed the strongest relationships between work schedule and depression, with increased odds ratios [ORs] for rapidly rotating (OR = 1.51, 95% confidence interval [CI] = 0.91-2.51) and undefined rotating (OR = 1.67, 95% CI = 0.92-3.02) shift workers, and a decreased OR for depression in slow rotating (OR = 0.79, 95% CI = 0.57-1.08) shift workers. For the low- and moderate-precision exposure grouping models, weak relationships were observed for all work schedule categories (OR range 0.95 to 0.99). Findings from this study support the need to consider and collect the data required for precise and conceptually driven exposure assessment and assignment in future studies of shift work and health. Further research into the effects of shift rotation frequency on depression is also recommended. © The Author(s) 2018. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Centroiding Experiment for Determining the Positions of Stars with High Precision
NASA Astrophysics Data System (ADS)
Yano, T.; Araki, H.; Hanada, H.; Tazawa, S.; Gouda, N.; Kobayashi, Y.; Yamada, Y.; Niwa, Y.
2010-12-01
We have experimented with the determination of the positions of star images on a detector with high precision such as 10 microarcseconds, required by a space astrometry satellite, JASMINE. In order to accomplish such a precision, we take the following two procedures. (1) We determine the positions of star images on the detector with the precision of about 0.01 pixel for one measurement, using an algorithm for estimating them from photon weighted means of the star images. (2) We determine the positions of star images with the precision of about 0.0001-0.00001 pixel, which corresponds to that of 10 microarcseconds, using a large amount of data over 10000 measurements, that is, the error of the positions decreases according to the amount of data. Here, we note that the procedure 2 is not accomplished when the systematic error in our data is not excluded adequately even if we use a large amount of data. We first show the method to determine the positions of star images on the detector using photon weighted means of star images. This algorithm, used in this experiment, is very useful because it is easy to calculate the photon weighted mean from the data. This is very important in treating a large amount of data. Furthermore, we need not assume the shape of the point spread function in deriving the centroid of star images. Second, we show the results in the laboratory experiment for precision of determining the positions of star images. We obtain that the precision of estimation of positions of star images on the detector is under a variance of 0.01 pixel for one measurement (procedure 1). We also obtain that the precision of the positions of star images becomes a variance of about 0.0001 pixel using about 10000 measurements (procedure 2).
Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems
NASA Technical Reports Server (NTRS)
Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.
2015-01-01
Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.
In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.
Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert
2016-09-01
Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. Impressions were obtained via two conventional (metal full-arch tray, CI, and triple tray, T-Tray) and seven digital impression systems (Lava True Definition Scanner, T-Def; Lava Chairside Oral Scanner, COS; Cadent iTero, ITE; 3Shape Trios, TRI; 3Shape Trios Color, TRC; CEREC Bluecam, Software 4.0, BC4.0; CEREC Bluecam, Software 4.2, BC4.2; and CEREC Omnicam, OC). Impressions were taken three times for each of five subjects (n = 15). The impressions were then superimposed within the test groups. Differences from model surfaces were measured using a normal surface distance method. Precision was calculated using the Perc90_10 value. The values for all test groups were statistically compared. The precision ranged from 18.8 (CI) to 58.5 μm (T-Tray), with the highest precision in the CI, T-Def, BC4.0, TRC, and TRI groups. The deviation pattern varied distinctly depending on the impression method. Impression systems with single-shot capture exhibited greater deviations at the tooth surface whereas high-frame rate impression systems differed more in gingival areas. Triple tray impressions displayed higher local deviation at the occlusal contact areas of upper and lower jaw. Digital quadrant impression methods achieve a level of precision, comparable to conventional impression techniques. However, there are significant differences in terms of absolute values and deviation pattern. With all tested digital impression systems, time efficient capturing of quadrant impressions is possible. The clinical precision of digital quadrant impression models is sufficient to cover a broad variety of restorative indications. Yet the precision differs significantly between the digital impression systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Guangye; Chacon, Luis; Barnes, Daniel C
2012-01-01
Recently, a fully implicit, energy- and charge-conserving particle-in-cell method has been developed for multi-scale, full-f kinetic simulations [G. Chen, et al., J. Comput. Phys. 230, 18 (2011)]. The method employs a Jacobian-free Newton-Krylov (JFNK) solver and is capable of using very large timesteps without loss of numerical stability or accuracy. A fundamental feature of the method is the segregation of particle orbit integrations from the field solver, while remaining fully self-consistent. This provides great flexibility, and dramatically improves the solver efficiency by reducing the degrees of freedom of the associated nonlinear system. However, it requires a particle push per nonlinearmore » residual evaluation, which makes the particle push the most time-consuming operation in the algorithm. This paper describes a very efficient mixed-precision, hybrid CPU-GPU implementation of the implicit PIC algorithm. The JFNK solver is kept on the CPU (in double precision), while the inherent data parallelism of the particle mover is exploited by implementing it in single-precision on a graphics processing unit (GPU) using CUDA. Performance-oriented optimizations, with the aid of an analytical performance model, the roofline model, are employed. Despite being highly dynamic, the adaptive, charge-conserving particle mover algorithm achieves up to 300 400 GOp/s (including single-precision floating-point, integer, and logic operations) on a Nvidia GeForce GTX580, corresponding to 20 25% absolute GPU efficiency (against the peak theoretical performance) and 50-70% intrinsic efficiency (against the algorithm s maximum operational throughput, which neglects all latencies). This is about 200-300 times faster than an equivalent serial CPU implementation. When the single-precision GPU particle mover is combined with a double-precision CPU JFNK field solver, overall performance gains 100 vs. the double-precision CPU-only serial version are obtained, with no apparent loss of robustness or accuracy when applied to a challenging long-time scale ion acoustic wave simulation.« less
Staggs, Vincent S; Cramer, Emily
2016-08-01
Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital-acquired pressure ulcer rates and evaluate a standard signal-noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step-down, medical, surgical, and medical-surgical nursing units from 1,299 US hospitals were analyzed. Using beta-binomial models, we estimated between-unit variability (signal) and within-unit variability (noise) in annual unit pressure ulcer rates. Signal-noise reliability was computed as the ratio of between-unit variability to the total of between- and within-unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal-noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal-noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Profe, Jörn; Ohlendorf, Christian
2017-04-01
XRF-scanning is the state-of-the-art technique for geochemical analyses in marine and lacustrine sedimentology for more than a decade. However, little attention has been paid to data precision and technical limitations so far. Using homogenized, dried and powdered samples (certified geochemical reference standards and samples from a lithologically-contrasting loess-paleosol sequence) minimizes many adverse effects that influence the XRF-signal when analyzing wet sediment cores. This allows the investigation of data precision under ideal conditions and documents a new application of the XRF core-scanner technology at the same time. Reliable interpretations of XRF results require data precision evaluation of single elements as a function of X-ray tube, measurement time, sample compaction and quality of peak fitting. Ten-fold measurement of each sample constitutes data precision. Data precision of XRF measurements theoretically obeys Poisson statistics. Fe and Ca exhibit largest deviations from Poisson statistics. The same elements show the least mean relative standard deviations in the range from 0.5% to 1%. This represents the technical limit of data precision achievable by the installed detector. Measurement times ≥ 30 s reveal mean relative standard deviations below 4% for most elements. The quality of peak fitting is only relevant for elements with overlapping fluorescence lines such as Ba, Ti and Mn or for elements with low concentrations such as Y, for example. Differences in sample compaction are marginal and do not change mean relative standard deviation considerably. Data precision is in the range reported for geochemical reference standards measured by conventional techniques. Therefore, XRF scanning of discrete samples provide a cost- and time-efficient alternative to conventional multi-element analyses. As best trade-off between economical operation and data quality, we recommend a measurement time of 30 s resulting in a total scan time of 30 minutes for 30 samples.
Molecular diffusion of stable water isotopes in polar firn as a proxy for past temperatures
NASA Astrophysics Data System (ADS)
Holme, Christian; Gkinis, Vasileios; Vinther, Bo M.
2018-03-01
Polar precipitation archived in ice caps contains information on past temperature conditions. Such information can be retrieved by measuring the water isotopic signals of δ18O and δD in ice cores. These signals have been attenuated during densification due to molecular diffusion in the firn column, where the magnitude of the diffusion is isotopologue specific and temperature dependent. By utilizing the differential diffusion signal, dual isotope measurements of δ18O and δD enable multiple temperature reconstruction techniques. This study assesses how well six different methods can be used to reconstruct past surface temperatures from the diffusion-based temperature proxies. Two of the methods are based on the single diffusion lengths of δ18O and δD , three of the methods employ the differential diffusion signal, while the last uses the ratio between the single diffusion lengths. All techniques are tested on synthetic data in order to evaluate their accuracy and precision. We perform a benchmark test to thirteen high resolution Holocene data sets from Greenland and Antarctica, which represent a broad range of mean annual surface temperatures and accumulation rates. Based on the benchmark test, we comment on the accuracy and precision of the methods. Both the benchmark test and the synthetic data test demonstrate that the most precise reconstructions are obtained when using the single isotope diffusion lengths, with precisions of approximately 1.0 °C . In the benchmark test, the single isotope diffusion lengths are also found to reconstruct consistent temperatures with a root-mean-square-deviation of 0.7 °C . The techniques employing the differential diffusion signals are more uncertain, where the most precise method has a precision of 1.9 °C . The diffusion length ratio method is the least precise with a precision of 13.7 °C . The absolute temperature estimates from this method are also shown to be highly sensitive to the choice of fractionation factor parameterization.
Towards Precision Spectroscopy of Baryonic Resonances
NASA Astrophysics Data System (ADS)
Döring, Michael; Mai, Maxim; Rönchen, Deborah
2017-01-01
Recent progress in baryon spectroscopy is reviewed. In a common effort, various groups have analyzed a set of new high-precision polarization observables from ELSA. The Jülich-Bonn group has finalized the analysis of pion-induced meson-baryon production, the potoproduction of pions and eta mesons, and (almost) the KΛ final state. As data become preciser, statistical aspects in the analysis of excited baryons become increasingly relevant and several advances in this direction are proposed.
The role of precise time in IFF
NASA Technical Reports Server (NTRS)
Bridge, W. M.
1982-01-01
The application of precise time to the identification of friend or foe (IFF) problem is discussed. The simple concept of knowing when to expect each signal is exploited in a variety of ways to achieve an IFF system which is hard to detect, minimally exploitable and difficult to jam. Precise clocks are the backbone of the concept and the various candidates for this role are discussed. The compact rubidium-controlled oscillator is the only practical candidate.
A Guide for Collecting Seismic, Acoustic, and Magnetic Data for Multiple Uses
1975-01-01
time, simul- (- taneously for the analog technique or sequentially for the digital tech- nique. Both methods require that precision timing networks be...with a precise voltage proportional to the sensitivity of the magnetometer . Whenever any electronic equip- ment affecting cal.bration has to be replaced...described as precisely as possible, including (but not limited to) the following: a. Name of source b. Continuous or transient c. Distance from geophone
2002-12-01
34th Annual Precise Time and Time Interval (PTTI) Meeting 243 IEEE-1588™ STANDARD FOR A PRECISION CLOCK SYNCHRONIZATION PROTOCOL FOR... synchronization . 2. Cyclic-systems. In cyclic-systems, timing is periodic and is usually defined by the characteristics of a cyclic network or bus...incommensurate, timing schedules for each device are easily implemented. In addition, synchronization accuracy depends on the accuracy of the common
Towards precision spectroscopy of baryonic resonances
Doring, Michael; Mai, Maxim; Ronchen, Deborah
2017-01-26
Recent progress in baryon spectroscopy is reviewed. In a common effort, various groups have analyzed a set of new high-precision polarization observables from ELSA. The Julich-Bonn group has finalized the analysis of pion-induced meson-baryon production, the potoproduction of pions and eta mesons, and (almost) the KΛ final state. Lastly, as data become preciser, statistical aspects in the analysis of excited baryons become increasingly relevant and several advances in this direction are proposed.
Influence of Structural Flexibility on the Dynamic Precision of a Vehicle-Mounted Equipment System
2015-05-12
Paramsothy Jayakumar , Dave Mechergui, Ronald Renke U.S.Army RDECOM TARDEC INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A...COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE INFLUENCE OF STRUCTURAL FLEXIBILITY ON THE DYNAMIC PRECISION OF A VEHICLE-MOUNTED EQUIPMENT...Equipment Enclosure CMS Results 23 12. Influence of CMS Method on the Vehicle Dynamics 24 13. Influence of Flexibility on the Vehicle
Automation of Die and Mold Polishing: A Preliminary Investigation
1990-02-02
Brittenham, B.S.M.E. The Ohio State University 1989 Master’s Examination Committees Approved by Taylan Altan Gary P. Maul Advisor College of Engineering...Corporation, Mount Prospect, Illinois, September 1989. 68. Showa Precision Machinery, Robo -Polisher, Model SMR-100, Showa Precision Machinery Catalog No...Abrasives." Wear, 18, No. 2 (1971), pp. 169-170. 132 Robo -Polisher, Hodel SHR-100. Showa Precision Hachinery Catalog No. August 88-4000. Amagasaki, Japan
Precision Measurement of Distribution of Film Thickness on Pendulum for Experiment of G
NASA Astrophysics Data System (ADS)
Liu, Lin-Xia; Guan, Sheng-Guo; Liu, Qi; Zhang, Ya-Ting; Shao, Cheng-Gang; Luo, Jun
2009-09-01
Distribution of film thickness coated on the pendulum of measuring the Newton gravitational constant G is determined with a weighing method by means of a precision mass comparator. The experimental result shows that the gold film on the pendulum will contribute a correction of -24.3 ppm to our G measurement with an uncertainty of 4.3 ppm, which is significant for improving the G value with high precision.
High-precision half-life determination for 21Na using a 4 π gas-proportional counter
NASA Astrophysics Data System (ADS)
Finlay, P.; Laffoley, A. T.; Ball, G. C.; Bender, P. C.; Dunlop, M. R.; Dunlop, R.; Hackman, G.; Leslie, J. R.; MacLean, A. D.; Miller, D.; Moukaddam, M.; Olaizola, B.; Severijns, N.; Smith, J. K.; Southall, D.; Svensson, C. E.
2017-08-01
A high-precision half-life measurement for the superallowed β+ transition between the isospin T =1 /2 mirror nuclei 21Na and 21Ne has been performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1 /2=22.4506 (33 ) s, a result that is a factor of 4 more precise than the previous world-average half-life for 21Na and represents the single most precisely determined half-life for a transition between mirror nuclei to date. The contribution to the uncertainty in the 21Na F tmirror value due to the half-life is now reduced to the level of the nuclear-structure-dependent theoretical corrections, leaving the branching ratio as the dominant experimental uncertainty.
Alignment of a vector magnetometer to an optical prism.
Dietrich, M R; Bailey, K G; O'Connor, T P
2017-05-01
A method for alignment of a vector magnetometer to a rigidly attached prism is presented. This enables optical comparison of the magnetometer axes to physical surfaces in the apparatus, and thus an absolute determination of the magnetic field direction in space. This is in contrast with more common techniques, which focus on precise determination of the relative angles between magnetometer axes, and so are more suited to measuring differences in the direction of magnetic fields. Here we demonstrate precision better than 500 μrad on a fluxgate magnetometer, which also gives the coil orthogonality errors to a similar precision. The relative sensitivity of the three axes is also determined, with a precision of about 5 × 10 -4 .
Self-Stabilizing Measurement of Phase
NASA Astrophysics Data System (ADS)
Vinjanampathy, Sai
2014-05-01
Measuring phase accurately constitutes one of the most important task in precision measurement science. Such measurements can be deployed to measure everything from fundamental constants to measuring detuning and tunneling rates of atoms more precisely. Quantum mechanics enhances the ultimate bounds on the precision of such measurements possible, and exploit coherence and entanglement to reduce the phase uncertainty. In this work, we will describe a method to stabilize a decohering two-level atom and use the stabilizing measurements to learn the unknown phase acquired by the atom. Such measurements will employ a Bayesian learner to do active feedback control on the atom. We will discuss some ultimate bounds employed in precision metrology and an experimental proposal for the implementation of this scheme. Financial support from Ministry of Education, Singapore.
Indexing system for optical beam steering
NASA Technical Reports Server (NTRS)
Sullivan, Mark T.; Cannon, David M.; Debra, Daniel B.; Young, Jeffrey A.; Mansfield, Joseph A.; Carmichael, Roger E.; Lissol, Peter S.; Pryor, G. M.; Miklosy, Les G.; Lee, Jeffrey H.
1990-01-01
This paper describes the design and testing of an indexing system for optical-beam steering. The cryogenic beam-steering mechanism is a 360-degree rotation device capable of discrete, high-precision alignment positions. It uses low-precision components for its rough alignment and kinematic design to meet its stringent repeatability and stability requirements (of about 5 arcsec). The principal advantages of this design include a decoupling of the low-precision, large angular motion from the high-precision alignment, and a power-off alignment position that potentially extends the life or hold time of cryogenic systems. An alternate design, which takes advantage of these attributes while reducing overall motion, is also presented. Preliminary test results show the kinematic mount capable of sub-arc second repeatability.
Imaging Optical Frequencies with 100 μHz Precision and 1.1 μm Resolution.
Marti, G Edward; Hutson, Ross B; Goban, Akihisa; Campbell, Sara L; Poli, Nicola; Ye, Jun
2018-03-09
We implement imaging spectroscopy of the optical clock transition of lattice-trapped degenerate fermionic Sr in the Mott-insulating regime, combining micron spatial resolution with submillihertz spectral precision. We use these tools to demonstrate atomic coherence for up to 15 s on the clock transition and reach a record frequency precision of 2.5×10^{-19}. We perform the most rapid evaluation of trapping light shifts and record a 150 mHz linewidth, the narrowest Rabi line shape observed on a coherent optical transition. The important emerging capability of combining high-resolution imaging and spectroscopy will improve the clock precision, and provide a path towards measuring many-body interactions and testing fundamental physics.
A precision mechanical nerve stimulator
NASA Technical Reports Server (NTRS)
Tcheng, Ping; Supplee, Frank H., Jr.; Prass, Richard L.
1988-01-01
An electromechanical device, used to apply and monitor stimulating pulses to a mammalian motor nerve, has been successfully developed at NASA Langley Research Center. Two existing force transducers, a flight skin friction balance and a miniature skin friction balance which were designed for making aerodynamic drag measurements, were modified and incorporated to form this precision instrument. The nerve stimulator is a type one servomechanism capable of applying and monitoring stimulating pulses of 0 to 10 grams with a precision of better than +/- 0.05 grams. Additionally, the device can be independently used to apply stimulating pulses by displacing the nerve from 0 to 0.25 mm with a precision of better than +/- 0.001 mm while measuring the level of the load applied.
Alania, M; De Backer, A; Lobato, I; Krause, F F; Van Dyck, D; Rosenauer, A; Van Aert, S
2017-10-01
In this paper, we investigate how precise atoms of a small nanocluster can ultimately be located in three dimensions (3D) from a tilt series of images acquired using annular dark field (ADF) scanning transmission electron microscopy (STEM). Therefore, we derive an expression for the statistical precision with which the 3D atomic position coordinates can be estimated in a quantitative analysis. Evaluating this statistical precision as a function of the microscope settings also allows us to derive the optimal experimental design. In this manner, the optimal angular tilt range, required electron dose, optimal detector angles, and number of projection images can be determined. Copyright © 2016 Elsevier B.V. All rights reserved.
A phase match based frequency estimation method for sinusoidal signals
NASA Astrophysics Data System (ADS)
Shen, Yan-Lin; Tu, Ya-Qing; Chen, Lin-Jun; Shen, Ting-Ao
2015-04-01
Accurate frequency estimation affects the ranging precision of linear frequency modulated continuous wave (LFMCW) radars significantly. To improve the ranging precision of LFMCW radars, a phase match based frequency estimation method is proposed. To obtain frequency estimation, linear prediction property, autocorrelation, and cross correlation of sinusoidal signals are utilized. The analysis of computational complex shows that the computational load of the proposed method is smaller than those of two-stage autocorrelation (TSA) and maximum likelihood. Simulations and field experiments are performed to validate the proposed method, and the results demonstrate the proposed method has better performance in terms of frequency estimation precision than methods of Pisarenko harmonic decomposition, modified covariance, and TSA, which contribute to improving the precision of LFMCW radars effectively.
Plasmonic micropillars for precision cell force measurement across a large field-of-view
NASA Astrophysics Data System (ADS)
Xiao, Fan; Wen, Ximiao; Tan, Xing Haw Marvin; Chiou, Pei-Yu
2018-01-01
A plasmonic micropillar platform with self-organized gold nanospheres is reported for the precision cell traction force measurement across a large field-of-view (FOV). Gold nanospheres were implanted into the tips of polymer micropillars by annealing gold microdisks with nanosecond laser pulses. Each gold nanosphere is physically anchored in the center of a pillar tip and serves as a strong, point-source-like light scattering center for each micropillar. This allows a micropillar to be clearly observed and precisely tracked even under a low magnification objective lens for the concurrent and precision measurement across a large FOV. A spatial resolution of 30 nm for the pillar deflection measurement has been accomplished on this platform with a 20× objective lens.
Analyzing Water's Optical Absorption
NASA Technical Reports Server (NTRS)
2002-01-01
A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.
Lee, Taehwa; Luo, Wei; Li, Qiaochu; Demirci, Hakan; Guo, L Jay
2017-10-01
Beyond the implementation of the photoacoustic effect to photoacoustic imaging and laser ultrasonics, this study demonstrates a novel application of the photoacoustic effect for high-precision cavitation treatment of tissue using laser-induced focused ultrasound. The focused ultrasound is generated by pulsed optical excitation of an efficient photoacoustic film coated on a concave surface, and its amplitude is high enough to produce controllable microcavitation within the focal region (lateral focus <100 µm). Such microcavitation is used to cut or ablate soft tissue in a highly precise manner. This work demonstrates precise cutting of tissue-mimicking gels as well as accurate ablation of gels and animal eye tissues. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Field comparison of several commercially available radon detectors.
Field, R W; Kross, B C
1990-01-01
To determine the accuracy and precision of commercially available radon detectors in a field setting, 15 detectors from six companies were exposed to radon and compared to a reference radon level. The detectors from companies that had already passed National Radon Measurement Proficiency Program testing had better precision and accuracy than those detectors awaiting proficiency testing. Charcoal adsorption detectors and diffusion barrier charcoal adsorption detectors performed very well, and the latter detectors displayed excellent time averaging ability. Alternatively, charcoal liquid scintillation detectors exhibited acceptable accuracy but poor precision, and bare alpha registration detectors showed both poor accuracy and precision. The mean radon level reported by the bare alpha registration detectors was 68 percent lower than the radon reference level. PMID:2368851
Shu, Deming; Shvydko, Yuri; Stoupin, Stanislav A.; Khachatryan, Ruben; Goetze, Kurt A.; Roberts, Timothy
2015-04-14
A method and an ultrahigh-resolution spectrometer including a precision mechanical structure for positioning inelastic X-ray scattering optics are provided. The spectrometer includes an X-ray monochromator and an X-ray analyzer, each including X-ray optics of a collimating (C) crystal, a pair of dispersing (D) element crystals, anomalous transmission filter (F) and a wavelength (W) selector crystal. A respective precision mechanical structure is provided with the X-ray monochromator and the X-ray analyzer. The precision mechanical structure includes a base plate, such as an aluminum base plate; positioning stages for D-crystal alignment; positioning stages with an incline sensor for C/F/W-crystal alignment, and the positioning stages including flexure-based high-stiffness structure.
Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis.
Matuszewski, B K
2006-01-18
A simple experimental approach for studying and identifying the relative matrix effect (for example "plasma-to-plasma" and/or "urine-to-urine") in quantitative analyses by HPLC-MS/MS is described. Using as a database a large number of examples of methods developed in recent years in our laboratories, the relationship between the precision of standard line slopes constructed in five different lots of a biofluid (for example plasma) and the reliability of determination of concentration of an analyte in a particular plasma lot (or subject) was examined. In addition, the precision of standard line slopes was compared when stable isotope-labeled analytes versus analogs were used as internal standards (IS). Also, in some cases, a direct comparison of standard line slopes was made when different HPLC-MS interfaces (APCI versus ESI) were used for the assay of the same compound, using the same IS and the same sample preparation and chromatographic separation conditions. In selected cases, the precision of standard line slopes in five different lots of a biofluid was compared with precision values determined five times in a single lot. The results of these studies indicated that the variability of standard line slopes in different lots of a biofluid [precision of standard line slopes expressed as coefficient of variation, CV (%)] may serve as a good indicator of a relative matrix effect and, it is suggested, this precision value should not exceed 3-4% for the method to be considered reliable and free from the relative matrix effect liability. Based on the results presented, in order to assess the relative matrix effect in bioanalytical methods, it is recommended to perform assay precision and accuracy determination in five different lots of a biofluid, instead of repeat (n=5) analysis in the same, single biofluid lot, calculate standard line slopes and precision of these slopes, and to use <3-4% slope precision value as a guide for method applicability to support clinical studies. It was also demonstrated that when stable isotope-labeled analytes were used as internal standards, the precision of standard line slopes in five different lots of a biofluid was =2.4% irrespective of the HPLC-MS interface utilized. This clearly indicated that, in all cases studied, the use of stable isotope-labeled IS eliminated relative matrix effect. Also, the utilization of the APCI interface instead of ESI led to the elimination of the relative matrix effect in all cases studied. When the precision of standard line slope values exceeds the 3-4% limit, the method may require improvements (a more efficient chromatography, a more selective extraction, a stable isotope-labeled IS instead of an analog as an IS, and/or a change in the HPLC-MS interface) to eliminate the relative matrix effect and to improve assay selectivity.
Rigorous high-precision enclosures of fixed points and their invariant manifolds
NASA Astrophysics Data System (ADS)
Wittig, Alexander N.
The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by Johannes Grote is extended to compute very accurate polynomial approximations to invariant manifolds of discrete maps of arbitrary dimension around hyperbolic fixed points. The algorithm presented allows for automatic removal of resonances occurring during construction. A method for the rigorous enclosure of invariant manifolds of continuous systems is introduced. Using methods developed for discrete maps, polynomial approximations of invariant manifolds of hyperbolic fixed points of ODEs are obtained. These approximations are outfit with a sharp error bound which is verified to rigorously contain the manifolds. While we focus on the three dimensional case, verification in higher dimensions is possible using similar techniques. Integrating the resulting enclosures using the verified COSY VI integrator, the initial manifold enclosures are expanded to yield sharp enclosures of large parts of the stable and unstable manifolds. To demonstrate the effectiveness of this method, we construct enclosures of the invariant manifolds of the Lorenz system and show pictures of the resulting manifold enclosures. To the best of our knowledge, these enclosures are the largest verified enclosures of manifolds in the Lorenz system in existence.
NASA Astrophysics Data System (ADS)
Dall'Ara, Enrico; Peña-Fernández, Marta; Palanca, Marco; Giorgi, Mario; Cristofolini, Luca; Tozzi, Gianluca
2017-11-01
Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-Computed Tomography (µCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application the precision of the method should be evaluated. In this paper we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source µCT or Synchrotron light µCT (SRµCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2500 micrometers. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time large differences in the precision of both local and global DVC approaches have been highlighted when SRµCT or in vivo µCT images were used instead of conventional ex vivo µCT. These findings suggest that in situ mechanical testing protocols applied in SRµCT facilities should be optimized in order to allow DVC analyses of localized strain measurements. Moreover, for in vivo µCT applications DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion, we have extensively shown that the precision of both tested DVC approaches is affected by different bone structures, different input image resolution and different subvolume sizes. Before each specific application DVC users should always apply a similar approach to find the best compromise between precision and spatial resolution of the measurements.
[Some reflections on evidenced-based medicine, precision medicine, and big data-based research].
Tang, J L; Li, L M
2018-01-10
Evidence-based medicine remains the best paradigm for medical practice. However, evidence alone is not decisions; decisions must also consider resources available and the values of people. Evidence shows that most of those treated with blood pressure-lowering, cholesterol-lowering, glucose-lowering and anti-cancer drugs do not benefit from preventing severe complications such as cardiovascular events and deaths. This implies that diagnosis and treatment in modern medicine in many circumstances is imprecise. It has become a dream to identify and treat only those few who can respond to the treatment. Precision medicine has thus come into being. Precision medicine is however not a new idea and cannot rely solely on gene sequencing as it was initially proposed. Neither is the large cohort and multi-factorial approach a new idea; in fact it has been used widely since 1950s. Since its very beginning, medicine has never stopped in searching for more precise diagnostic and therapeutic methods and already made achievements at various levels of our understanding and knowledge, such as vaccine, blood transfusion, imaging, and cataract surgery. Genetic biotechnology is not the only path to precision but merely a new method. Most genes are found only weakly associated with disease and are thus unlikely to lead to great improvement in diagnostic and therapeutic precision. The traditional multi-factorial approach by embracing big data and incorporating genetic factors is probably the most realistic way ahead for precision medicine. Big data boasts of possession of the total population and large sample size and claims correlation can displace causation. They are serious misleading concepts. Science has never had to observe the totality in order to draw a valid conclusion; a large sample size is required only when the anticipated effect is small and clinically less meaningful; emphasis on correlation over causation is equivalent to rejection of the scientific principles and methods in epidemiology and a call to give up the assurance for validity in scientific research, which will inevitably lead to futile interventions. Furthermore, in proving the effectiveness of intervention, analyses of real-world big data cannot displace the role of randomized controlled trial. We expressed doubts and critiques in this article on precision medicine and big data, merely hoping to stimulate discussing on the true potentials of precision medicine and big data.
Riegel, Adam C; Chen, Yu; Kapur, Ajay; Apicello, Laura; Kuruvilla, Abraham; Rea, Anthony J; Jamshidi, Abolghassem; Potters, Louis
Optically stimulated luminescent dosimeters (OSLDs) are utilized for in vivo dosimetry (IVD) of modern radiation therapy techniques such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Dosimetric precision achieved with conventional techniques may not be attainable. In this work, we measured accuracy and precision for a large sample of clinical OSLD-based IVD measurements. Weekly IVD measurements were collected from 4 linear accelerators for 2 years and were expressed as percent differences from planned doses. After outlier analysis, 10,224 measurements were grouped in the following way: overall, modality (photons, electrons), treatment technique (3-dimensional [3D] conformal, field-in-field intensity modulation, inverse-planned IMRT, and VMAT), placement location (gantry angle, cardinality, and central axis positioning), and anatomical site (prostate, breast, head and neck, pelvis, lung, rectum and anus, brain, abdomen, esophagus, and bladder). Distributions were modeled via a Gaussian function. Fitting was performed with least squares, and goodness-of-fit was assessed with the coefficient of determination. Model means (μ) and standard deviations (σ) were calculated. Sample means and variances were compared for statistical significance by analysis of variance and the Levene tests (α = 0.05). Overall, μ ± σ was 0.3 ± 10.3%. Precision for electron measurements (6.9%) was significantly better than for photons (10.5%). Precision varied significantly among treatment techniques (P < .0001) with field-in-field lowest (σ = 7.2%) and IMRT and VMAT highest (σ = 11.9% and 13.4%, respectively). Treatment site models with goodness-of-fit greater than 0.90 (6 of 10) yielded accuracy within ±3%, except for head and neck (μ = -3.7%). Precision varied with treatment site (range, 7.3%-13.0%), with breast and head and neck yielding the best and worst precision, respectively. Placement on the central axis of cardinal gantry angles yielded more precise results (σ = 8.5%) compared with other locations (range, 10.5%-11.4%). Accuracy of ±3% was achievable. Precision ranged from 6.9% to 13.4% depending on modality, technique, and treatment site. Simple, standardized locations may improve IVD precision. These findings may aid development of patient-specific tolerances for OSLD-based IVD. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.
Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim
2017-09-01
Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0 ±6.6 μm and mean precision of 16.9 ±5.8 μm than optical impressions with a mean trueness of 46.2 ±11.4 μm and mean precision of 61.1 ±4.9 μm. Complete arch (first molar-to-first molar) optical impressions were less accurate than conventional impressions but may be adequate for quadrant impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lösel, P.
2017-06-01
Large area Micromegas detectors will be employed for the first time in high-energy physics experiments. To cope with increasing background rates, associated with the steadily increasing luminosity of LHC to 10 times design luminosity, the present detector technology in the current innermost stations of the muon endcap system of the ATLAS experiment (the Small Wheel), will be replaced in 2019/2020 by resistive strip Micromegas and small strip TGC detectors. Both technologies will provide tracking and trigger information. In the "New Small Wheel" the Micromegas will be arranged in eight detection layers built of trapezoidally shaped quadruplets of four different sizes covering in total about 1200 m2 of detection plane. In order to achieve 15 % transverse momentum resolution for 1 TeV muons, a challenging mechanical precision is required in the construction of each active plane, with an alignment of the readout strips at the level of 30 μm RMS along the precision coordinate and 80 μm RMS perpendicular to the plane. Each individual Micromegas plane must achieve a spatial resolution better than 100 μm at background rates up to 15 kHz/cm2 while being operated in an inhomogeneous magnetic field (B <= 0.3 T). The required mechanical precision for the production of the components and their assembly, on such large area detectors, is a key point and must be controlled during construction and integration. Particularly the alignment of the readout strips within a quadruplet appears to be demanding. The readout strips are etched on PCB boards using photolithographic processes. Depending on the type of the module, 3 or 5 PCB boards need to be joined and precisely aligned to form a full readout plane. The precision in the alignment is reached either by use of precision mechanical holes or by optical masks, both referenced to the strip patterns. Assembly procedures have been developed to build the single panels with the required mechanical precision and to assemble them in a module including the four metallic micro-meshes. Methods to confirm the precision of components and assembly are based on precise optical devices and X-ray or cosmic muon investigations. We will report on the construction procedures for the Micromegas quadruplets, on the quality control procedures and results, and on the assembly and calibration methods.
Holloway, Andrew J; Oshlack, Alicia; Diyagama, Dileepa S; Bowtell, David DL; Smyth, Gordon K
2006-01-01
Background Concerns are often raised about the accuracy of microarray technologies and the degree of cross-platform agreement, but there are yet no methods which can unambiguously evaluate precision and sensitivity for these technologies on a whole-array basis. Results A methodology is described for evaluating the precision and sensitivity of whole-genome gene expression technologies such as microarrays. The method consists of an easy-to-construct titration series of RNA samples and an associated statistical analysis using non-linear regression. The method evaluates the precision and responsiveness of each microarray platform on a whole-array basis, i.e., using all the probes, without the need to match probes across platforms. An experiment is conducted to assess and compare four widely used microarray platforms. All four platforms are shown to have satisfactory precision but the commercial platforms are superior for resolving differential expression for genes at lower expression levels. The effective precision of the two-color platforms is improved by allowing for probe-specific dye-effects in the statistical model. The methodology is used to compare three data extraction algorithms for the Affymetrix platforms, demonstrating poor performance for the commonly used proprietary algorithm relative to the other algorithms. For probes which can be matched across platforms, the cross-platform variability is decomposed into within-platform and between-platform components, showing that platform disagreement is almost entirely systematic rather than due to measurement variability. Conclusion The results demonstrate good precision and sensitivity for all the platforms, but highlight the need for improved probe annotation. They quantify the extent to which cross-platform measures can be expected to be less accurate than within-platform comparisons for predicting disease progression or outcome. PMID:17118209
Scheerlinck, Thierry; Polfliet, Mathias; Deklerck, Rudi; Van Gompel, Gert; Buls, Nico; Vandemeulebroucke, Jef
2016-01-01
We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SD(SE)): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SD(SE): 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice.
Snow, Richard A.; Porta, Michael J.; Long, James M.
2018-01-01
The White Perch Morone americana is an invasive species in many Midwestern states and is widely distributed in reservoir systems, yet little is known about the species' age structure and population dynamics. White Perch were first observed in Sooner Reservoir, a thermally altered cooling reservoir in Oklahoma, by the Oklahoma Department of Wildlife Conservation in 2006. It is unknown how thermally altered systems like Sooner Reservoir may affect the precision of White Perch age estimates. Previous studies have found that age structures from Largemouth Bass Micropterus salmoides and Bluegills Lepomis macrochirus from thermally altered reservoirs had false annuli, which increased error when estimating ages. Our objective was to quantify the precision of White Perch age estimates using four sagittal otolith preparation techniques (whole, broken, browned, and stained). Because Sooner Reservoir is thermally altered, we also wanted to identify the best month to collect a White Perch age sample based on aging precision. Ages of 569 White Perch (20–308 mm TL) were estimated using the four techniques. Age estimates from broken, stained, and browned otoliths ranged from 0 to 8 years; whole‐view otolith age estimates ranged from 0 to 7 years. The lowest mean coefficient of variation (CV) was obtained using broken otoliths, whereas the highest CV was observed using browned otoliths. July was the most precise month (lowest mean CV) for estimating age of White Perch, whereas April was the least precise month (highest mean CV). These results underscore the importance of knowing the best method to prepare otoliths for achieving the most precise age estimates and the best time of year to obtain those samples, as these factors may affect other estimates of population dynamics.
Huang, Yuansheng; Yang, Zhirong; Wang, Jing; Zhuo, Lin; Li, Zhixia; Zhan, Siyan
2016-05-06
To compare the performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from The Cochrane Library. Databases of CDSR and DARE in the Cochrane Library were searched for systematic reviews of diagnostic test accuracy published between 2008 and 2012 through nine search strategies. Each strategy consists of one group or combination of groups of searching filters about diagnostic test accuracy. Four groups of diagnostic filters were used. The Strategy combing all the filters was used as the reference to determine the sensitivity, precision, and the sensitivity x precision product for another eight Strategies. The reference Strategy retrieved 8029 records, of which 832 were eligible. The strategy only composed of MeSH terms about "accuracy measures" achieved the highest values in both precision (69.71%) and product (52.45%) with a moderate sensitivity (75.24%). The combination of MeSH terms and free text words about "accuracy measures" contributed little to increasing the sensitivity. Strategies composed of filters about "diagnosis" had similar sensitivity but lower precision and product to those composed of filters about "accuracy measures". MeSH term "exp'diagnosis' " achieved the lowest precision (9.78%) and product (7.91%), while its hyponym retrieved only half the number of records at the expense of missing 53 target articles. The precision was negatively correlated with sensitivities among the nine strategies. Compared to the filters about "diagnosis", the filters about "accuracy measures" achieved similar sensitivities but higher precision. When combining both terms, sensitivity of the strategy was enhanced obviously. The combination of MeSH terms and free text words about the same concept seemed to be meaningless for enhancing sensitivity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Braian, Michael; Jönsson, David; Kevci, Mir; Wennerberg, Ann
2018-07-01
To evaluate the accuracy and precision of objects produced by additive manufacturing systems (AM) for use in dentistry and to compare with subtractive manufacturing systems (SM). Ten specimens of two geometrical objects were produced by five different AM machines and one SM machine. Object A mimics an inlay-shaped object, while object B imitates a four-unit bridge model. All the objects were sorted into different measurement dimensions (x, y, z), linear distances, angles and corner radius. None of the additive manufacturing or subtractive manufacturing groups presented a perfect match to the CAD file with regard to all parameters included in the present study. Considering linear measurements, the precision for subtractive manufacturing group was consistent in all axes for object A, presenting results of <0.050mm. The additive manufacturing groups had consistent precision in the x-axis and y-axis but not in the z-axis. With regard to corner radius measurements, the SM group had the best overall accuracy and precision for both objects A and B when compared to the AM groups. Within the limitations of this in vitro study, the conclusion can be made that subtractive manufacturing presented overall precision on all measurements below 0.050mm. The AM machines also presented fairly good precision, <0.150mm, on all axes except for the z-axis. Knowledge regarding accuracy and precision for different production techniques utilized in dentistry is of great clinical importance. The dental community has moved from casting to milling and additive techniques are now being implemented. Thus all these production techniques need to be tested, compared and validated. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Hind, Karen; Oldroyd, Brian; Truscott, John G
2010-01-01
Knowledge of precision is integral to the monitoring of bone mineral density (BMD) changes using dual-energy X-ray absorptiometry (DXA). We evaluated the precision for bone measurements acquired using a GE Lunar iDXA (GE Healthcare, Waukesha, WI) in self-selected men and women, with mean age of 34.8 yr (standard deviation [SD]: 8.4; range: 20.1-50.5), heterogeneous in terms of body mass index (mean: 25.8 kg/m(2); SD: 5.1; range: 16.7-42.7 kg/m(2)). Two consecutive iDXA scans (with repositioning) of the total body, lumbar spine, and femur were conducted within 1h, for each subject. The coefficient of variation (CV), the root-mean-square (RMS) averages of SDs of repeated measurements, and the corresponding 95% least significant change were calculated. Linear regression analyses were also undertaken. We found a high level of precision for BMD measurements, particularly for scans of the total body, lumbar spine, and total hip (RMS: 0.007, 0.004, and 0.007 g/cm(2); CV: 0.63%, 0.41%, and 0.53%, respectively). Precision error for the femoral neck was higher but still represented good reproducibility (RMS: 0.014 g/cm(2); CV: 1.36%). There were associations between body size and total-body BMD and total-hip BMD SD precisions (r=0.534-0.806, p<0.05) in male subjects. Regression parameters showed good association between consecutive measurements for all body sites (r(2)=0.98-0.99). The Lunar iDXA provided excellent precision for BMD measurements of the total body, lumbar spine, femoral neck, and total hip. Copyright © 2010 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Lee, Yoojin; Callaghan, Martina F; Nagy, Zoltan
2017-01-01
In magnetic resonance imaging, precise measurements of longitudinal relaxation time ( T 1 ) is crucial to acquire useful information that is applicable to numerous clinical and neuroscience applications. In this work, we investigated the precision of T 1 relaxation time as measured using the variable flip angle method with emphasis on the noise propagated from radiofrequency transmit field ([Formula: see text]) measurements. The analytical solution for T 1 precision was derived by standard error propagation methods incorporating the noise from the three input sources: two spoiled gradient echo (SPGR) images and a [Formula: see text] map. Repeated in vivo experiments were performed to estimate the total variance in T 1 maps and we compared these experimentally obtained values with the theoretical predictions to validate the established theoretical framework. Both the analytical and experimental results showed that variance in the [Formula: see text] map propagated comparable noise levels into the T 1 maps as either of the two SPGR images. Improving precision of the [Formula: see text] measurements significantly reduced the variance in the estimated T 1 map. The variance estimated from the repeatedly measured in vivo T 1 maps agreed well with the theoretically-calculated variance in T 1 estimates, thus validating the analytical framework for realistic in vivo experiments. We concluded that for T 1 mapping experiments, the error propagated from the [Formula: see text] map must be considered. Optimizing the SPGR signals while neglecting to improve the precision of the [Formula: see text] map may result in grossly overestimating the precision of the estimated T 1 values.
Precise and accurate isotope ratio measurements by ICP-MS.
Becker, J S; Dietze, H J
2000-09-01
The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.
NASA Astrophysics Data System (ADS)
Deng, Hui; Chen, Genyu; He, Jie; Zhou, Cong; Du, Han; Wang, Yanyi
2016-06-01
In this study, an online, efficient and precision laser profiling approach that is based on a single-layer deep-cutting intermittent feeding method is described. The effects of the laser cutting depth and the track-overlap ratio of the laser cutting on the efficiency, precision and quality of laser profiling were investigated. Experiments on the online profiling of bronze-bonded diamond grinding wheels were performed using a pulsed fiber laser. The results demonstrate that an increase in the laser cutting depth caused an increase in the material removal efficiency during the laser profiling process. However, the maximum laser profiling efficiency was only achieved when the laser cutting depth was equivalent to the initial surface contour error of the grinding wheel. In addition, the selection of relatively high track-overlap ratios of laser cutting for the profiling of grinding wheels was beneficial with respect to the increase in the precision of laser profiling, whereas the efficiency and quality of the laser profiling were not affected by the change in the track-overlap ratio. After optimized process parameters were employed for online laser profiling, the circular run-out error and the parallelism error of the grinding wheel surface decreased from 83.1 μm and 324.6 μm to 11.3 μm and 3.5 μm, respectively. The surface contour precision of the grinding wheel significantly improved. The highest surface contour precision for grinding wheels of the same type that can be theoretically achieved after laser profiling is completely dependent on the peak power density of the laser. The higher the laser peak power density is, the higher the surface contour precision of the grinding wheel after profiling.
MINOS Timing and GPS Precise Point Positioning
2012-01-01
Minos Timing Spec • Neutrinos created in bunches separated by 19 ns • ~ 1 neutrino/day detected in Soudan Mine – 2 milliseconds travel time...calibration – No low-cost Fermilab to Soudan Mine connections known – Not yet tested for operational time transfer Clock Options • High-Performance... UNDERGROUND LABORATORY •;, ~ (((ft.F ~’: · GPS PRECISE POINT POSITIONING A Brief Overview What is GPS PPP? • GPS PPP is a way to use precise ephemerides
Precision segmented reflector, figure verification sensor
NASA Technical Reports Server (NTRS)
Manhart, Paul K.; Macenka, Steve A.
1989-01-01
The Precision Segmented Reflector (PSR) program currently under way at the Jet Propulsion Laboratory is a test bed and technology demonstration program designed to develop and study the structural and material technologies required for lightweight, precision segmented reflectors. A Figure Verification Sensor (FVS) which is designed to monitor the active control system of the segments is described, a best fit surface is defined, and an image or wavefront quality of the assembled array of reflecting panels is assessed