Rocío-Bautista, Priscilla; Martínez-Benito, Carla; Pino, Verónica; Pasán, Jorge; Ayala, Juan H; Ruiz-Pérez, Catalina; Afonso, Ana M
2015-07-01
Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(Al), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-µ-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 μgL(-1) for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R(2)) higher than 0.9966 for a range of 0.5-147 μgL(-1) (depending on the paraben), average relative recoveries (RR, in %) of 80.3% at the low spiked level (7 μgL(-1)), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 ± 0.01 μgg(-1) for EPB in the healing cream analyzed to 1.12 ± 0.07 mgg(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-µ-SPE procedures despite sample complexity. Copyright © 2015 Elsevier B.V. All rights reserved.
Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo; Baugh, Steve
2012-01-01
A method was developed for microplate-based oxygen radicals absorbance capacity (ORAC) using pyrogallol red (PGR) as probe (ORAC-PGR). The method was evaluated for linearity, precision, and accuracy. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, was measured. Linearity of the area under the curve (AUC) versus Trolox concentration plots was [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM]; R = 0.9961, n = 19]. Analyses showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and recovery (REC) values of 1.7 and 101.0%, respectively. The method also showed good linearity for red wine [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a wide range of results, from 0.6 to 21.6 mM of Trolox equivalents. Product-to-product variability was also observed for juices of the same fruit, showing the differences between brands on the ORAC-PGR index.
de Andrade, Jucimara Kulek; de Andrade, Camila Kulek; Komatsu, Emy; Perreault, Hélène; Torres, Yohandra Reyes; da Rosa, Marcos Roberto; Felsner, Maria Lurdes
2017-08-01
Corn syrups, important ingredients used in food and beverage industries, often contain high levels of 5-hydroxymethyl-2-furfural (HMF), a toxic contaminant. In this work, an in house validation of a difference spectrophotometric method for HMF analysis in corn syrups was developed using sophisticated statistical tools by the first time. The methodology showed excellent analytical performance with good selectivity, linearity (R 2 =99.9%, r>0.99), accuracy and low limits (LOD=0.10mgL -1 and LOQ=0.34mgL -1 ). An excellent precision was confirmed by repeatability (RSD (%)=0.30) and intermediate precision (RSD (%)=0.36) estimates and by Horrat value (0.07). A detailed study of method precision using a nested design demonstrated that variation sources such as instruments, operators and time did not interfere in the variability of results within laboratory and consequently in its intermediate precision. The developed method is environmentally friendly, fast, cheap and easy to implement resulting in an attractive alternative for corn syrups quality control in industries and official laboratories. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development and validation of an LC-UV method for the determination of sulfonamides in animal feeds.
Kumar, P; Companyó, R
2012-05-01
A simple LC-UV method was developed for the determination of residues of eight sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimidine, sulfadoxine, sulfamethoxypyridazine, sulfaquinoxaline, sulfamethoxazole, and sulfadimethoxine) in six types of animal feed. C18, Oasis HLB, Plexa and Plexa PCX stationary phases were assessed for the clean-up step and the latter was chosen as it showed greater efficiency in the clean-up of interferences. Feed samples spiked with sulfonamides at 2 mg/kg were used to assess the trueness (recovery %) and precision of the method. Mean recovery values ranged from 47% to 66%, intra-day precision (RSD %) from 4% to 15% and inter-day precision (RSD %) from 7% to 18% in pig feed. Recoveries and intra-day precisions were also evaluated in rabbit, hen, cow, chicken and piglet feed matrices. Calibration curves with standards prepared in mobile phase and matrix-matched calibration curves were compared and the matrix effects were ascertained. The limits of detection and quantification in the feeds ranged from 74 to 265 µg/kg and from 265 to 868 µg/kg, respectively. Copyright © 2011 John Wiley & Sons, Ltd.
Li, Wei; Herrman, Timothy J; Dai, Susie Y
2010-01-01
A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.
Analytical parameters of the microplate-based ORAC-pyrogallol red assay.
Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo
2011-01-01
The analytical parameters of the microplate-based oxygen radicals absorbance capacity (ORAC) method using pyrogallol red (PGR) as probe (ORAC-PGR) are presented. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, is estimated. A good linearity of the area under the curve (AUC) versus Trolox concentration plots was obtained [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM], R = 0.9961, n = 19]. QC experiments showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and REC (recuperation) values of 1.7 and 101.0%, respectively. When red wine was used as sample, the method also showed good linearity [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Additivity assays using solutions containing gallic acid and Trolox (or red wine) showed an additive protection of PGR given by the samples. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a great variability, ranging from 0.6 to 21.6 mM of Trolox equivalents. This variability was also observed for juices of the same fruit, showing the influence of the brand on the ORAC-PGR index. The ORAC-PGR methodology can be applied in a microplate reader with good linearity, precision, and accuracy.
Spectrophotometric determination of ofloxacin in pharmaceuticals by redox reaction
NASA Astrophysics Data System (ADS)
Ramesh, P. J.; Basavaiah, K.; Rajendraprasad, N.; Devi, O. Zenita; Vinay, K. B.
2011-07-01
Two simple spectrophotometric methods have been developed to analyze ofloxacin (OFX) in pharmaceuticals. The methods are based on the oxidation of OFX by a measured excess of cerium(IV) sulfate in H2SO4 medium. This was followed by the determination of the unreacted oxidant by reacting it with either p-toluidine ( p-TD) and measuring the absorbance at 525 nm (method A) or o-dianisidine ( o-DA) and measuring the absorbance at 470 nm (method B). In both methods, the amount of cerium(IV) sulfate reacted corresponds to the amount of OFX. Calibration graphs were linear over the ranges of 0-120 and 0-4 g/ml OFX for methods A and B, respectively. The calculated molar absorptivity (2.34ṡ103 and 5.99ṡ104), Sandell sensitivity, and limit of quantification for the methods are reported. The intra-day precision (%RSD) and accuracy (%RE) were < 8.0 and ≤ 4.0%, respectively, and the inter-day RSD and RE values were within 5 and 4.0%, respectively. The applicability of the methods was demonstrated by determining OFX in tablets with an accuracy (%RE) of < 3% and precision (%RSD) of ≤2.65%. The accuracy of the methods was further ascertained by recovery experiments via a standard-addition procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.
ABSTRACT In order to meet a growing need for fieldable mass spectrometer systems for precise elemental and isotopic analyses, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) has a number of very promising characteristics. One key set of attributes that await validation deals with the performance characteristics relative to isotope ratio precision and accuracy. Due to its availability and prior experience with this research team, the initial evaluation of isotope ratio (IR) performance was performed on a Thermo Scientific Exactive Orbitrap instrument. While the mass accuracy and resolution performance for orbitrap analyzers are very well documented, no detailed evaluations of themore » IR performance have been published. Efforts described here involve two variables: the inherent IR precision and accuracy delivered by the LSAPGD microplasma and the inherent IR measurement qualities of orbitrap analyzers. Important to the IR performance, the various operating parameters of the orbitrap sampling interface, HCD dissociation stage, and ion injection/data acquisition have been evaluated. The IR performance for a range of other elements, including natural, depleted, and enriched uranium isotopes was determined. In all cases the precision and accuracy are degraded when measuring low abundance (<0.1% isotope fractions). In the best case, IR precision on the order of 0.1 %RSD can be achieved, with values of 1-3 %RSD observed for low-abundance species. The results suggest that the LSAPGD is a very good candidate for field deployable MS analysis and that the high resolving powers of the orbitrap may be complemented with a here-to-fore unknown capacity to deliver high-precision isotope ratios.« less
Ilem-Ozdemir, Derya; Gundogdu, Evren; Ekinci, Meliha; Ozgenc, Emre; Asikoglu, Makbule
2015-01-01
The purpose of this work is to prepare a self-microemulsifying drug delivery system (SMEDDS) for risedronate sodium (RSD) and to compare the permeability with RSD solution. The solubility of RSD was determined in different vehicles. Phase diagrams were constructed to determine the optimum concentration of oil, surfactant, and cosurfactant. RSD SMEDDS was prepared by using a mixture of soybean oil, cremophor EL, span 80, and transcutol (2.02:7.72:23.27:61.74, w/w, respectively). The prepared RSD SMEDDS was characterized by droplet size value. In vitro Caco-2 cell permeability studies were performed for SMEDDS and solution of radioactive ((99 m)Tc-labeled RSD) and nonradioactive RSD. The experimental results indicated that RSD SMEDDS has good stability and its droplet size is between 216.68 ± 3.79 and 225.26 ± 7.65 during stability time. In addition, RSD SMEDDS has higher permeability value than the RSD solution for both radioactive and nonradioactive experiments. The results illustrated the potential use of SMEDDS for delivery of poorly absorbed RSD.
Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M
2010-01-01
A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.
GFAAS determination of selenium in infant formulas using a microwave digestion method.
Alegria, A; Barbera, R; Farré, R; Moreno, A
1994-01-01
A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.
Weon, Jin Bae; Yang, Hye Jin; Ma, Jin Yeul; Ma, Choong Je
2011-01-01
Background: Bangpungtongsung-san, one of the traditional herbal medicines, was known to be a prescription for obesity. Objective: For the simultaneous determination of five components (paeoniflorin, 6-gingerol, decursin, geniposide, and glycyrrhizin) in Bangpungtongsung-san, a high-performance liquid chromatography with diode-array detector method was established. Materials and Methods: To develop the method, a reverse phase column, DIONEX C 18 (5 μm, 120 µ, 4.6 mm × 150 mm) was used. The mobile phase consisted of methanol and water using a gradient elution. The UV wavelength was set at 230, 240, and 254 nm. Method validation was accomplished by linearity, precision test, and recovery test. Results: All calibration curves of components showed good linearity (R 2 > 0.9959). The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01 to 0.17 μg/ml and 0.04 to 0.53 μg/ml, respectively. The relative standard deviations (RSD) value of precision test, intraday and interday tests were less than 0.43% and 1.26%. In the recovery test, results of accuracy ranged from 95.27% to 107.70% with RSD values less than 2.21%. Conclusion: This developed method was applied to the commercial Bangpungtongsung-san sample and the five marker components were separated effectively without interference of any peaks of components. PMID:21472081
NASA Astrophysics Data System (ADS)
Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.; Hart, Garret L.; Koppenaal, David W.; Marcus, R. Kenneth
2016-08-01
In order to meet a growing need for fieldable mass spectrometer systems for precise elemental and isotopic analyses, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) has a number of very promising characteristics. One key set of attributes that await validation deals with the performance characteristics relative to isotope ratio precision and accuracy. Owing to its availability and prior experience with this research team, the initial evaluation of isotope ratio (IR) performance was performed on a Thermo Scientific Exactive Orbitrap instrument. While the mass accuracy and resolution performance for Orbitrap analyzers are well-documented, no detailed evaluations of the IR performance have been published. Efforts described here involve two variables: the inherent IR precision and accuracy delivered by the LS-APGD microplasma and the inherent IR measurement qualities of Orbitrap analyzers. Important to the IR performance, the various operating parameters of the Orbitrap sampling interface, high-energy collisional dissociation (HCD) stage, and ion injection/data acquisition have been evaluated. The IR performance for a range of other elements, including natural, depleted, and enriched uranium isotopes was determined. In all cases, the precision and accuracy are degraded when measuring low abundance (<0.1% isotope fractions). In the best case, IR precision on the order of 0.1% RSD can be achieved, with values of 1%-3% RSD observed for low-abundance species. The results suggest that the LS-APGD is a promising candidate for field deployable MS analysis and that the high resolving powers of the Orbitrap may be complemented with a here-to-fore unknown capacity to deliver high-precision IRs.
Static Scene Statistical Non-Uniformity Correction
2015-03-01
Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion
Choodum, Aree; Parabun, Kaewalee; Klawach, Nantikan; Daeid, Niamh Nic; Kanatharana, Proespichaya; Wongniramaikul, Worawit
2014-02-01
The Simon presumptive color test was used in combination with the built-in digital camera on a mobile phone to detect methamphetamine. The real-time Red-Green-Blue (RGB) basic color data was obtained using an application installed on the mobile phone and the relationship profile between RGB intensity, including other calculated values, and the colourimetric product was investigated. A wide linear range (0.1-2.5mg mL(-1)) and a low detection limit (0.0110±0.0001-0.044±0.002mg mL(-1)) were achieved. The method also required a small sample size (20μL). The results obtained from the analysis of illicit methamphetamine tablets were comparable to values obtained from gas chromatograph-flame ionization detector (GC-FID) analysis. Method validation indicated good intra- and inter-day precision (2.27-4.49%RSD and 2.65-5.62%RSD, respectively). The results suggest that this is a powerful real-time mobile method with the potential to be applied in field tests. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Precise and accurate isotope ratio measurements by ICP-MS.
Becker, J S; Dietze, H J
2000-09-01
The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.
Garrido Frenich, Antonia; Martín Fernández, María del Mar; Díaz Moreno, Laura; Martínez Vidal, Jose Lúis; López-Gutiérrez, Noelia
2012-01-01
A simple, rapid, and reliable multiresidue method to determine 84 pesticides in potato and carrot samples by ultra-performance liquid chromatography coupled to MS/MS has been developed and fully validated for routine analysis according to ISO/IEC 17025:2005. The method makes use of a buffered Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) sample preparation procedure based on a single extraction with acidified acetonitrile, followed by partitioning with salts. Chromatographic conditions were optimized in order to achieve a rapid separation in the multiple reaction monitoring mode. Performance characteristics of the method, including an estimation of measurement uncertainty using validation data, are reported for both matrixes. Calibration curves were linear from 0.010 to 0.150 mg/kg for most compounds. The LOD and LOQ were 0.006 and 0.010 mg/kg, respectively, except for fluorocloridone, fluquinconazol, and hexitiazox, which were 0.030 and 0.050 mg/kg, respectively. Recoveries obtained were in the range 70-116%, with intraday precision values < or = 20% RSD and interday precision values < or = 25% RSD at two different concentration levels. The overall uncertainty of the method was estimated at two concentrations as being lower than 34% in all cases. The method has been applied to the analysis of 70 vegetable samples, and imidacloprid and linuron were the pesticides most frequently found in potato and carrot commodities, respectively.
High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.
Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng
2009-02-01
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.
Chang, Yuwei; Zhao, Chunxia; Wu, Zeming; Zhou, Jia; Zhao, Sumin; Lu, Xin; Xu, Guowang
2012-08-01
In this work a chip-based nano HPLC coupled MS (HPLC-chip/MS) method with a simple sample preparation procedure was developed for the flavonoid profiling of soybean. The analytical properties of the method including the linearity (R(2) , 0.992-0.995), reproducibility (RSD, 1.50-7.66%), intraday precision (RSD, 1.41-5.14%) and interday precision (RSD, 2.76-16.90%) were satisfactory. Compared with the conventional HPLC/MS method, a fast extraction and analysis procedure was applied and more flavonoids were detected in a single run. Additionally, 13 flavonoids in soybean seed were identified for the first time. The method was then applied to the profiling of six varieties of soybean sowed at the same place. A clear discrimination was observed among different cultivars, three isoflavones, accounting for nearly 80% of total flavonoid contents, were found increased in the spring soybeans compared with the summer cultivars. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Yongyi; Xu, Jinzhong; Qu, Haibin
2013-01-01
A simple and accurate analytical method was developed for simultaneous quantification of three steroidal saponins in the roots of Ophiopogon japonicus via high-performance liquid chromatography (HPLC) with mass spectrometry (MS) in this study. Separation was performed on a Tigerkin C(18) column and detection was performed by mass spectrometry. A mobile phase consisted of 0.02% formic acid in water (v/v) and 0.02% formic acid in acetonitrile (v/v) was used with a flow rate of 0.5 mL min(-1). The quantitative HPLC-MS method was validated for linearity, precision, repeatability, stability, recovery, limits of detection and quantification. This developed method provides good linearity (r >0.9993), intra- and inter-day precisions (RSD <4.18%), repeatability (RSD <5.05%), stability (RSD <2.08%) and recovery (93.82-102.84%) for three steroidal saponins. It could be considered as a suitable quality control method for O. japonicus.
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
Holland, Patrick T; Cargill, Anne; Selwood, Andrew I; Arnold, Kate; Krammer, Jacqueline L; Pearce, Kevin N
2011-05-25
Immunoglobulin-containing food products and nutraceuticals such as bovine colostrum are of interest to consumers as they may provide health benefits. Commercial scale colostrum products are valued for their immunoglobulin G (IgG) content and therefore require accurate analysis. One of the most commonly used methods for determining total soluble IgG in colostrum products is based on affinity chromatography using a Protein G column and UV detection. This paper documents improvements to the accuracy of the Protein G analysis of IgG in colostrum products, especially those containing aggregated forms of IgG. Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) analysis confirmed that aggregated IgG measured by Protein G does not contain significant amounts of casein or other milk proteins. Size exclusion chromatography identified the content of soluble IgG as mainly monomeric IgG and aggregated material MW > 450 kDa with small amounts of dimer and trimer. The turbidity of the eluting IgG, mainly associated with aggregated IgG, had a significant effect on the quantitative results. Practical techniques were developed to correct affinity LC data for turbidity on an accurate, consistent, and efficient basis. The method was validated in two laboratories using a variety of colostrum powders. Precision for IgG was 2-3% (RSD(r)) and 3-12% (RSD(R)). Recovery was 100.2 ± 2.4% (mean ± RSD, n = 10). Greater amounts of aggregated IgG were solubilized by a higher solution:sample ratio and extended times of mixing or sonication, especially for freeze-dried material. It is concluded that the method without acid precipitation and with turbidity correction provides accurate, precise, and robust data for total soluble IgG and is suitable for product specification and quality control of colostrum products.
Suzuki, Ippei; Kubota, Hiroki; Ohtsuki, Takashi; Tatebe, Chiye; Tada, Atsuko; Yano, Takeo; Akiyama, Hiroshi; Sato, Kyoko
2016-01-01
A rapid, sensitive, and specific analytical method for the determination of 1-hydroxyethylidene-1,1-diphosphonic acid (HEDP) on uncooked foods after treatment with a peracetic acid-based sanitizer (PAS) was developed. The method involves simple sample preparation steps and analysis using ion chromatography (IC) coupled with tandem mass spectrometry (MS/MS). The quantification limits of HEDP on uncooked foods are 0.007 mg/kg for vegetables and fruits and 0.2 mg/kg for meats. The recovery and relative standard deviation (RSD) of HEDP analyses of uncooked foods ranged from 73.9 to 103.8% and 1.9 to 12.6%, respectively. The method's accuracy and precision were evaluated by inter-day recovery tests. The recovery for all samples ranged from 93.6 to 101.2%, and the within-laboratory repeatability and reproducibility were evaluated based on RSD values, which were less than 6.9 and 11.5%, respectively. Analyses of PAS-treated fruits and vegetables using the developed method indicated levels of HEDP ranging from 0.008 to 0.351 mg/kg. Therefore, the results of the present study suggest that the proposed method is an accurate, precise, and reliable way to determine residual HEDP levels on PAS-treated uncooked foods.
Determination of (187)Os in molybdenite by ICP-MS with neutron-induced (186)Os and (188)Os spikes.
Qu, W; Du, A; Zhao, D
2001-10-31
The article describes a method for the determination of (187)Os in molybdenite by isotope dilution inductively coupled plasma-mass spectrometry (ID-ICP-MS) with neutron-induced (186)Os and (188)Os spike. The spike used in the present work was prepared in line with the principle by which artificial nuclides are produced in a nuclear reaction. The concentration and isotopic composition of osmium in the prepared spike were evaluated accurately with the isotope dilution method, using negative thermal ion mass spectrometry (N-TIMS). The advantage of this method is that using (186)Os and (188)Os double spikes can effectively compensate for the mass discrimination effects of ICP-MS. Thus, the common correction practice for mass bias in the isotope dilution method with a single spike is unnecessary. In addition, the method enables one to reduce the determined error arising from instrumental instability. The precision for the (187)Os/((186)Os+(188)Os) ratio was approximately 2% (2sigma, RSD), but in the case of (187)Os/(186)Os, (187)Os/(188)Os and (186)Os/(188)Os, precision ranged from 2.0 to 8% (2sigma, RSD). The results for (187)Os concentration in a molybdenite sample determined with this method showed good agreement with reference values.
[Determination of doping in human urine by gas chromatography-high resolution mass spectrometry].
Xing, Yan-Yi; Liu, Xin; Zhang, Yu-Mei; Wang, Xiao-Bing; Xu, You-Xuan
2012-12-01
A method was evaluated for determination of twenty-one doping (including nandrolone, boldenone and methandienone) in human urine by gas chromatography-high resolution mass spectrometry. Samples were prepared by liquid-liquid extraction, concentrated, TMS derivatization and limit of detection at ng x mL(-1) by MID/GC/HRMS. According to the code of the World Anti-Doping Agency (WADA), precision and recoveries of the procedure were evaluated by replicate analysis (n = 6), the recoveries in the range of 66%-103%, with the RSD below 10.0%. The precision within the day of the method with three different concentrations was also determined RSD were less than 9.5%, 10.0% and 9.7%.
Hou, Jin-Jun; Guo, Ji-Ling; Cao, Chun-Mei; Yao, Shuai; Long, Hua-Li; Cai, Lu-Ying; Da, Juan; Wu, Wan-Ying; Guo, De-An
2018-04-01
Triglycerides are the primary constituents of some seed kernels used in traditional Chinese medicine. Quality control of seed kernels containing multiple components with an environmentally friendly method is indispensable for establishing their quality standards (called monographs) in pharmacopeia. Using coix seeds (Semen Coicis) as an example, a green quantification strategy was proposed by combining C 8 core-shell particles with single standard to determine multicomponent technologies to quantify seven triglycerides simultaneously. A core-shell column, namely, Halo C 8 (3.0 × 100 mm, 2.7 µm), was used. Methanol was used as the mobile phase at a flow rate of 0.3 mL/min, enabling UV detection of the elutes. Seven triglycerides were well separated in 20 min, and simultaneously quantified using triolein as a single standard. The conversion factor for each standard was set as 1.0 on ELSD, while for the conversion factors at 203 nm, the values increased with the reduction of linoleate. The recovery values were all in the range of 97 - 107% (RSD < 3.0%). The RSD values of precision, including intraday and intermediate precision, were < 3.0% when the total content of triglycerides was calculated. The linearity reached r ≥ 0.9990, and the limit of quantitation reached 40 - 70 ng. Forty-nine batches of coix seeds from four different places of origins and eight batches of adulterants were evaluated and differentiated using principal component analysis. In addition, the validated method was used successfully to quantity seven triglycerides in Semen Persicae, Semen Armeniacae Amarum, and Semen Pruni. Georg Thieme Verlag KG Stuttgart · New York.
Validated method for the analysis of goji berry, a rich source of zeaxanthin dipalmitate.
Karioti, Anastasia; Bergonzi, Maria Camilla; Vincieri, Franco F; Bilia, Anna Rita
2014-12-31
In the present study an HPLC-DAD method was developed for the determination of the main carotenoid, zeaxanthin dipalmitate, in the fruits of Lycium barbarum. The aim was to develop and optimize an extraction protocol to allow fast, exhaustive, and repeatable extraction, suitable for labile carotenoid content. Use of liquid N2 allowed the grinding of the fruit. A step of ultrasonication with water removed efficiently the polysaccharides and enabled the exhaustive extraction of carotenoids by hexane/acetone 50:50. The assay was fast and simple and permitted the quality control of a large number of commercial samples including fruits, juices, and a jam. The HPLC method was validated according to ICH guidelines and satisfied the requirements. Finally, the overall method was validated for precision (% RSD ranging between 3.81 and 4.13) and accuracy at three concentration levels. The recovery was between 94 and 107% with RSD values <2%, within the acceptable limits, especially if the difficulty of the matrix is taken into consideration.
Cherstniakova, Svetlana A; Garcia, Gregory E; Strong, John; Bi, Daoqin; Weitz, Julie; Roy, Michael J; Cantilena, Louis R
2006-01-01
A rapid and highly sensitive gas chromatography-mass spectrometry (GC-MS) method for simultaneous determination of N,N-diethyl-m-toluamide (DEET) and permethrin with (2)H(10)-phenanthrene (98 atom %) as an internal standard and a separate external standard high-performance liquid chromatography (HPLC) method for pyridostigmine bromide (PB) determination in human plasma were developed and validated. The GC-MS method for DEET and permethrin quantification utilizes a one-step extraction with tert-butylmethylether. The HPLC method for PB quantification involves a solid-phase extraction and UV detection. The range of the analytical method for DEET and permethrin was 1 ng/mL to 100 ng/mL and for PB was 5 ng/mL to 100 ng/mL. Recovery from plasma proved to be more than 80%. The intraday precision ranged from 1.3% to 8% for DEET, from 2.1% to 11.4% for permethrin, and from 3.0% to 4.8% for PB. The interday precision was 3% for DEET, ranged from 5% to 9% for permethrin, and from 5% to 9% for PB. The accuracy for the limit of quantification was 92% +/- 8% relative standard deviation (RSD) for DEET, 112% +/- 11% RSD for permethrin, and 109% +/- 5% RSD for PB. All 3 compounds were stable in human plasma at -80 degrees C for at least 12 months and after 2 freeze-thaw cycles with RSD values ranging from 7.1% (DEET, 80 ng/mL) to 8.1% (DEET, 8 ng/mL), from 2.3% (permethrin, 80 ng/mL) to 11.6 % (permethrin, 8 ng/mL), and from 0.2% (PB, 80 ng/mL) to 3.6% (PB, 8 ng/mL). Both methods were successfully applied to pharmacokinetic/ pharmacodynamic studies of combined exposure of DEET (skin application), permethrin (treated uniforms), and PB (30 mg orally three times/day for four doses) in healthy volunteers (n = 81).
Rapid Quantification of N-Methyl-2-pyrrolidone in Polymer Matrices by Thermal Desorption-GC/MS.
Kim, Young-Min; Kim, Jae Woo; Moon, Hye Mi; Lee, Min-Jin; Hosaka, Akihiko; Watanabe, Atsushi; Teramae, Norio; Park, Young-Kwon; Myung, Seung-Woon
2017-01-01
Analysis of a residual solvent in polymeric materials has become an important issue due to the increased regulations and standards for its use. N-Methyl-2-pyrrolidone (NMP) is a solvent widely used in many industries and restricted as one of the chemicals under EU REACH regulations due to its potential harmful effects. In this study, thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) is applied for the quantitative analysis of NMP with the use of a polymer-coated sample cup. By using the polymer-coated sample cup, the vaporization of NMP was prevented during waiting time before TD-GC/MS analysis. The calibration curve for the TD method showed good linearity (correlation coefficient, r 2 = 0.9998) and precision values (below 5.3% RSD). NMP recovery rates in different polymer matrices (PS, PMMA and PVC) were in the range of 98.8 to 106.6% with RSD values below 5.0%. The quantification result (600 mg NMP/kg PVC) for the blind NMP carrying sample in a PVC matrix by TD-GC/MS was higher than that (532 mg NMP/kg PVC) by solvent extraction-GC/MS method.
Cheng, Zhipeng; Dong, Fengshou; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Chen, Zenglong; Pan, Xinglu; Gan, Jay; Zheng, Yongquan
2017-09-15
This paper describes the application of atmospheric pressure gas chromatography quadrupole-time-of-flight mass spectrometry for the simultaneous determination of organophosphorus pesticides in apple, pear, tomato, cucumber and cabbage. Soft ionization with atmospheric pressure ionization source was compared with traditional electron impact ionization (EI). The sensitivity of GC coupled to atmospheric pressure ionization (APGC) for all the analytes was enhanced by 1.0-8.2 times. The ionization modes with atmospheric pressure ionization source was studied by comparing the charge-transfer and proton-transfer conditions. The optimized QuEChERs method was used to pretreat the samples. The calibration curves were found linear from 10 to 1000μg/L, obtaining correlation coefficients higher than 0.9845. Satisfactory mean recovery values, in the range of 70.0-115.9%, and satisfactory precision, with all RSD r <19.7% and all RSD R values <19.5% at the three fortified concentration levels for all the fifteen OPPs. The results demonstrate the potential of APGC-QTOF-MS for routine quantitative analysis of organophosphorus pesticide in fruits and vegetables. Copyright © 2017 Elsevier Ltd. All rights reserved.
da Silva, Layzon Antonio Lemos; Pezzini, Bianca Ramos; Soares, Luciano
2015-01-01
Background: The chemical characterization is essential to validate the pharmaceutical use of vegetable raw materials. Ultraviolet spectroscopy is an important technique to determine flavonoids, which are important active compounds from Ocimum basilicum. Objective: The objective of this work was to optimize a spectrophotometric method, based on flavonoid-aluminum chloride (AlCl3) complexation to determine the total flavonoid content (TFC) in leaves of O. basilicum (herbal material), using response surface methodology. Materials and Methods: The effects of (1) the herbal material: Solvent ratio (0.02, 0.03, 0.05, 0.07, and 0.08 g/mL), (2) stock solution volume (0.8, 2.3, 4.4, 6.5, and 8.0 mL) and (3) AlCl3 volume (0.8, 1.0, 1.2, 1.4, and 1.6 mL) on the TFC were evaluated. The analytical performance parameters precision, linearity and robustness of the method were tested. Results: The herbal material: Solvent ratio and stock solution volume showed an important influence on the method response. After choosing the optimized conditions, the method exhibited a precision (RSD%) lower than 6% for repeatability (RSD%) and lower than 8% for intermediate precision (on the order of literature values for biotechnological methods), coefficient of correlation of 0.9984, and no important influence could be observed for variations of the time of complexation with AlCl3. However, the time and temperature of extraction were critical for TFC method and must be carefully controlled during the analysis. Conclusion: Thus, this study allowed the optimization of a simple, fast and precise method for the determination of the TFC in leaves of O. basilicum, which can be used to support the quality assessment of this herbal material. PMID:25709217
Inglis, Jeremy D.; Maassen, Joel; Kara, Azim; ...
2017-04-28
This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240Pu isotope. Accurate analysis of <1 femtogram of 240Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization massmore » spectrometry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inglis, Jeremy D.; Maassen, Joel; Kara, Azim
This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240Pu isotope. Accurate analysis of <1 femtogram of 240Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization massmore » spectrometry.« less
Validation of a spectrophotometric assay method for bisoprolol using picric acid.
Panainte, Alina-Diana; Bibire, Nela; Tântaru, Gladiola; Apostu, M; Vieriu, Mădălina
2013-01-01
Bisoprolol is a drug belonging to beta blockers drugs used primarily for the treatment of cardiovascular diseases. A spectrophotometric method for quantitative determination of bisoprolol was developed based on the formation of a complex combination between bisoprolol and picric acid. The complex combination of bisoprolol and picric acid has a maximum absorbance peak at 420 nm. Optimum working conditions were established and the method was validated. The method presented a good linearity in the concentration range 5-120 microg/ml (regression coefficient r2 = 0.9992). The RSD for the precision of the method was 1.74 and for the intermediate precision 1.43, and recovery values ranged between 98.25-101.48%. The proposed and validated spectrophotometric method for the determination of bisoprolol is simple and cost effective.
Dash, Alekha K; Sawhney, Angeli
2002-07-31
The objective of this study was to develop a simple and sensitive LC method for the determination of creatine and creatinine in various creatine supplement formulations. The chromatographic system comprised of a LC-600 pump, SCL-6B system controller, and SPD-6AV detector (Shimadzu, Japan). The mobile phase consisted of 0.045 M ammonium sulfate in water. The chromatographic separation was achieved at ambient temperature on a Betabasic C-18 column (250 x 4.6 mm, Keystone Sci.). The flow rate was maintained at 0.75 ml/min and effluents are monitored at 205 nm. 4-(2-Aminoethyl)benzene sulfonamide was used as an internal standard (IS). This method required less than 7 min of chromatographic time. The standard curves were linear over the concentration range of 1-100 microg/ml for creatine and 2-100 microg/ml for creatinine, respectively. The relative standard deviations (RSD) for the within-day and day-to-day precision for creatine were within 1.0-4.6 and 2.2-4.7%, respectively. The RSD for the accuracy of creatine assay was in the range of 2.4-4.7%. The RSD values for the within-day precision, day-to-day precision and accuracy for creatinine validation were 1.7-4.4, 2.3-5.4 and 2.4-4.8%, respectively. This method was used to determine: (i) the creatine concentration in various marketed products; (ii) saturated solubility of various creatine salts; and (iii) stability of creatine in aqueous solution. In conclusion, a simple and sensitive LC method with UV detection was developed for the simultaneous determination of creatine and creatinine in formulations. Di-creatine citrate salt showed a higher aqueous solubility (at 25 degrees C) as compared to creatine and creatine monohydrate. Some of the over-the-counter (OTC) products tested contained a very low level of creatine in contrast to their label claim. Substantial conversion of creatine into creatinine was noticed in liquid formulation.
Lozano, Ana; Pérez-Parada, Andrés; Heinzen, Horacio; Fernández-Alba, Amadeo R
2012-01-01
In spite of high plant growth regulator application rates, little has been reported in the literature on determination of their residues in fruits and vegetables. This would be useful in monitoring good manufacturing practices and overall safety through the enforcement of maximum residue levels (MRLs). The present work describes method validation for the determination of 1-naphthylacetic acid (NAA) and 2(1-naphthyl)acetamide (NAAm) in tomato and zucchini using the mini-Luke, ethyl acetate (EtOAc) and acetate-buffered quick, easy, cheap, effective, rugged, and safe (QuEChERS) methods. Samples were spiked at two different levels: 50 and 100 pg/kg for NAA and 20 and 100 pg/kg for NAAm. These compounds were analyzed within the same chromatographic run with LC coupled to triple quadrupole MS (LC/(QqQ)MS/MS) in positive and negative electrospray ionization [ESI(+) and ESI(-)] modes for NAAm and NAA, respectively. For analyte confirmation, LC/ESI(-)QTOF-MS was also investigated given that NAA has only one multiple reaction monitoring transition (185.1-*140.9 m/z). These three common methods were used to determine linearity, recoveries, precision (RSD), matrix effects, repeatability, and reproducibility (n = 5) for the selected matrixes. In terms of the Directorate-General for Health and Consumers (DG-SANCO) guidelines, only insignificant differences were found for the multiresidue methods tested, regardless of the commodity. Matrix-matched calibration was used, and LODs were below 10.1 pg/kg for NAA and 6.0 pg/kg for NAAm, which were lower than the MRLs established in current European Union legislation for these compounds. Obtained recoveries for NAA ranged from 87 to 107% with RSD values below 10% for mini-Luke, 83 to 107% with RSD <11% for EtOAc, and 76 to 85% with RSD <7% for QuEChERS. NAAm recoveries ranged from 74 to 102% with RSD 5 15% for mini-Luke, 76 to 97% with RSD <4% for EtOAc, and 76 to 93% with RSD < 5% for QuEChERS. The linearity of the response over two orders of magnitude was demonstrated (r2 > 0.996) for all methods used. Good repeatability and reproducibility in terms of RSD were obtained (11.3-17.8%) for these analytical methods. The results were acceptable within the studied ranges for both analytes in all methods. As these multiresidue methods are used at the present time in many laboratories, this survey indicates that these analytes should be included in their monitoring scope.
Ishak, Ismarulyusda; Rosli, Farah Dayana; Mohamed, Jamaludin; Mohd Ismail, Muhammad Faiz
2015-01-01
Background Microwave is the most reliable sample digestion method. However, it requires expensive microwave digester automation and has relatively low productivity. In this study, three non-automated digestion methods, i.e. wet acid digestion using nitric acid (HNO3) and hydrogen peroxide (H2O2), wet acid digestion using HNO3, and dry washing, are compared in order to determine the best approach. Methods Certified reference material IAEA-086 (International Atomic Energy Agency, Austria) and hair and nail samples from 20 female students of Universiti Kebangsaan Malaysia, aged 19 to 30 years, were collected and analysed using the three digestion methods. Results For hair samples, analysis of variance of repeated measures showed significant differences in the level of all elements (P < 0.001) between the three methods. For nail samples, only the copper (Cu) level showed no significant difference (P = 0.100) between methods. Wet acid digestion using HNO3 and H2O2 showed the best within- and between-run relative standard deviation (RSD) values, with within-run RSD for all elements, except for selenium (Se), < 5%. The between-run precision ranges from 6.14% to 17.96% for hair and from 3.53% to 11.52% for nail samples. Wet acid digestion using HNO3 and H2O2 showed both good accuracy and precision for manganese (Mn) and magnesium (Mg), with percentage recoveries of 110% and 96.9%, respectively. All elements show higher method detection limit (MDL) values than the previous study: 0.05 μg/g Mg for wet acid digestion using HNO3, 0.02 μg/g Se for wet acid digestion using HNO3 and H2O2, and 0.2 μg/g Mg for dry ash method. Conclusion Wet acid digestion using HNO3 and H2O2 proved to be the best method in terms of precision, accuracy, recovery, and MDL. However, only Mn and Mg showed adequate precision, accuracy, and percentage of recovery. PMID:28223880
Verification of spectrophotometric method for nitrate analysis in water samples
NASA Astrophysics Data System (ADS)
Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu
2017-12-01
The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.
Determination of d-limonene in adipose tissue by gas chromatography-mass spectrometry
Miller, Jessica A.; Hakim, Iman A.; Thomson, Cynthia; Thompson, Patricia; Chow, H-H. Sherry
2008-01-01
We developed a novel method for analyzing d-limonene levels in adipose tissue. Fat samples were subjected to saponification followed by solvent extraction. d-Limonene in the sample extract was analyzed using gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring. Linear calibration curves were established over the mass range of 79.0-2,529 ng d-limonene per 0.1 grams of adipose tissue. Satisfactory within day precision (RSD 6.7 to 9.6%) and accuracy (% difference of −2.7 to 3.8%) and between day precision (RSD 6.0 to 10.7%) and accuracy (% difference of 1.8 to 2.6%) were achieved. The assay was successfully applied to human fat biopsy samples from a d-limonene feeding trial. PMID:18571481
Dörr, Oliver; Liebetrau, Christoph; Möllmann, Helge; Mahfoud, Felix; Ewen, Sebastian; Gaede, Luise; Troidl, Christian; Hoffmann, Jedrzej; Busch, Nikolai; Laux, Gerald; Wiebe, Jens; Bauer, Timm; Hamm, Christian; Nef, Holger
2015-02-01
Renal sympathetic denervation (RSD) represents a potential treatment option for certain patients with resistant arterial hypertension (HT). HT is associated with chronic vascular inflammation and remodeling, contributing to progressive vascular damage, and atherosclerosis. The present study aimed to evaluate the influence of RSD on cardiovascular inflammation and remodeling by determining serum levels of interleukin-6 (IL-6), high-sensitive C-reactive protein (hsCRP), matrix metalloproteinases (MMP), and tissue inhibitor of metalloproteinases (TIMP). A total of 60 consecutive patients (age 67.9 ± 9.6 years) undergoing RSD were included. A therapeutic response was defined as an office systolic blood pressure (SBP) reduction of >10 mmHg 6 months after RSD. Venous serum samples for measurement of hsCRP, IL-6, MMP-2, MMP-9, and TIMP-1 were collected prior to and 6 months after RSD. A significant reduction in office SBP of 26.4 mmHg [SBPbaseline 169.3 mmHg (SD 11.3), p < 0.001] was documented 6 months after RSD. The serum levels of hsCRP (p < 0.001) and the pro-inflammatory cytokine IL-6 (p < 0.001) were significantly decreased compared to baseline values. The levels of MMP-9 (p = 0.024) and MMP-2 (p < 0.01) were significantly increased compared to baseline values. In addition to the effective blood pressure reduction in response to RSD, this study demonstrates a positive effect of RSD on biomarkers reflecting vascular inflammation and remodeling. These results suggest a possible prognostic benefit of RSD in high-risk patients for endothelial dysfunction and cardiovascular remodeling as well as end-organ damage.
Seo, Chang-Seob; Kim, Seong-Sil; Ha, Hyekyung
2013-01-01
This study was designed to perform simultaneous determination of three reference compounds in Syzygium aromaticum (SA), gallic acid, ellagic acid, and eugenol, and to investigate the chemical antagonistic effect when combining Curcuma aromatica (CA) with SA, based on chromatographic analysis. The values of LODs and LOQs were 0.01–0.11 μg/mL and 0.03–0.36 μg/mL, respectively. The intraday and interday precisions were <3.0 of RSD values, and the recovery was in the range of 92.19–103.24%, with RSD values <3.0%. Repeatability and stability were 0.38–0.73% and 0.49–2.24%, respectively. Compared with the content of reference and relative peaks in SA and SA combined with CA (SAC), the amounts of gallic acid and eugenol were increased, while that of ellagic acid was decreased in SAC (compared with SA), and most of peak areas in SA were reduced in SAC. Regression analysis of the relative peak areas between SA and SAC showed r 2 values >0.87, indicating a linear relationship between SA and SAC. These results demonstrate that the components contained in CA could affect the extraction of components of SA mainly in a decreasing manner. The antagonistic effect of CA on SA was verified by chemical analysis. PMID:23878761
Vera-Avila, Luz E; Rojo-Portillo, Tania; Covarrubias-Herrera, Rosario; Peña-Alvarez, Araceli
2013-12-17
Dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFO) is one of the most interesting sample preparation techniques developed in recent years. Although several applications have been reported, the potentiality and limitations of this simple and rapid extraction technique have not been made sufficiently explicit. In this work, the extraction efficiency of DLLME-SFO for pollutants from different chemical families was determined. Studied compounds include: 10 polycyclic aromatic hydrocarbons, 5 pesticides (chlorophenoxy herbicides and DDT), 8 phenols and 6 sulfonamides, thus, covering a large range of polarity and hydrophobicity (LogKow 0-7, overall). After optimization of extraction conditions using 1-dodecanol as extractant, the procedure was applied for extraction of each family from 10-mL spiked water samples, only adjusting sample pH as required. Absolute recoveries for pollutants with LogKow 3-7 were >70% and recovery values within this group (18 compounds) were independent of structure or hydrophobicity; the precision of recovery was very acceptable (RSD<12%) and linear behavior was observed in the studied concentration range (r(2)>0.995). Extraction recoveries for pollutants with LogKow 1.46-2.8 were in the range 13-62%, directly depending on individual LogKow values; however, good linearity (r(2)>0.993) and precision (RSD<6.5%) were also demonstrated for these polar solutes, despite recovery level. DLLME-SFO with 1-dodecanol completely failed for extraction of compounds with LogKow≤1 (sulfa drugs), other more polar extraction solvents (ionic liquids) should be explored for highly hydrophilic pollutants. Copyright © 2013 Elsevier B.V. All rights reserved.
Hefnawy, Mohamed M; Sultan, Maha A; Al-Johar, Haya I; Kassem, Mohamed G; Aboul-Enein, Hassan Y
2012-01-01
Multiple response simultaneous optimization employing Derringer's desirability function was used for the development of a capillary electrophoresis method for the simultaneous determination of rosiglitazone (RSG) and glimepiride (GLM) in plasma and formulations. Twenty experiments, taking the two resolutions, the analysis time, and the capillary current as the responses with three important factors--buffer morality, volte and column temperature--were used to design mathematical models. The experimental responses were fitted into a second order polynomial and the six responses were simultaneously optimized to predict the optimum conditions for the effective separation of the studied compounds. The separation was carried out by using capillary zone electrophoresis (CZE) with a silica capillary column and diode array detector at 210 nm. The optimum assay conditions were 52 mmol l⁻¹ phosphate buffer, pH 7, and voltage of 22 kV at 29 °C. The method showed good agreement between the experimental data and predictive value throughout the studied parameter space. The assay limit of detection was 0.02 µg ml⁻¹ and the effective working range at relative standard deviation (RSD) of ≤ 5% was 0.05-16 µg ml⁻¹ (r = 0.999) for both drugs. Analytical recoveries of the studied drugs from spiked plasma were 97.2-101.9 ± 0.31-3.0%. The precision of the assay was satisfactory; RSD was 1.07 and 1.14 for intra- and inter-assay precision, respectively. The proposed method has a great value in routine analysis of RSG and GLM for its therapeutic monitoring and pharmacokinetic studies. Copyright © 2011 John Wiley & Sons, Ltd.
D'Autry, Ward; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Van Schepdael, Ann
2011-07-01
Gas chromatography-mass spectrometry is a well established analytical technique. However, mass spectrometers with electron ionization sources may suffer from signal drifts, hereby negatively influencing quantitative performance. To demonstrate this phenomenon for a real application, a static headspace-gas chromatography method in combination with electron ionization-quadrupole mass spectrometry was optimized for the determination of residual dichloromethane in coronary stent coatings. Validating the method, the quantitative performance of an original stainless steel ion source was compared to that of a modified ion source. Ion source modification included the application of a gold coating on the repeller and exit plate. Several validation aspects such as limit of detection, limit of quantification, linearity and precision were evaluated using both ion sources. It was found that, as expected, the stainless steel ion source suffered from signal drift. As a consequence, non-linearity and high RSD values for repeated analyses were obtained. An additional experiment was performed to check whether an internal standard compound would lead to better results. It was found that the signal drift patterns of the analyte and internal standard were different, consequently leading to high RSD values for the response factor. With the modified ion source however, a more stable signal was observed resulting in acceptable linearity and precision. Moreover, it was also found that sensitivity improved compared to the stainless steel ion source. Finally, the optimized method with the modified ion source was applied to determine residual dichloromethane in the coating of coronary stents. The solvent was detected but found to be below the limit of quantification. Copyright © 2011 Elsevier B.V. All rights reserved.
Rapid planar chromatographic analysis of 25 water-soluble dyes used as food additives.
Morlock, Gertrud E; Oellig, Claudia
2009-01-01
A rapid planar chromatographic method for identification and quantification of 25 water-soluble dyes in food was developed. In a horizontal developing chamber, the chromatographic separation on silica gel 60F254 high-performance thin-layer chromatography plates took 12 min for 40 runs in parallel, using 8 mL ethyl acetate-methanol-water-acetic acid (65 + 23 + 11 + 1, v/v/v/v) mobile phase up to a migration distance of 50 mm. However, the total analysis time, inclusive of application and evaluation, took 60 min for 40 runs. Thus, the overall time/run can be calculated as 1.5 min with a solvent consumption of 200 microL. A sample throughput of 1000 runs/8 h day can be reached by switching between the working stations (application, development, and evaluation) in a 20 min interval, which triples the analysis throughput. Densitometry was performed by absorption measurement using the multiwavelength scan mode in the UV and visible ranges. Repeatabilities [relative standard deviation (RSD), 4 determinations] at the first or second calibration level showed precisions of mostly < or = 2.7%, ranging between 0.2 and 5.2%. Correlation coefficient values (R > or = 0.9987) and RSD values (< or = 4.2%) of the calibration curves were highly satisfactory using classical quantification. However, digital evaluation of the plate image was also used for quantification, which resulted in RSD values of the calibration curves of mostly < or = 3.0%, except for two < or = 6.0%. The method was applied for the analysis of some energy drinks and bakery ink formulations, directly applied after dilution. By recording of absorbance spectra in the visible range, the identities of the dyes found in the samples were ascertained by comparison with the respective standard bands (correlation coefficients > or = 0.9996). If necessary for confirmation, online mass spectra were recorded within a minute.
Validation of a mass spectrometry-based method for milk traces detection in baked food.
Lamberti, Cristina; Cristina, Lamberti; Acquadro, Elena; Elena, Acquadro; Corpillo, Davide; Davide, Corpillo; Giribaldi, Marzia; Marzia, Giribaldi; Decastelli, Lucia; Lucia, Decastelli; Garino, Cristiano; Cristiano, Garino; Arlorio, Marco; Marco, Arlorio; Ricciardi, Carlo; Carlo, Ricciardi; Cavallarin, Laura; Laura, Cavallarin; Giuffrida, Maria Gabriella; Gabriella, Giuffrida Maria
2016-05-15
A simple validated LC-MS/MS-based method was set up to detect milk contamination in bakery products, taking the effects of food processing into account for the evaluation of allergen recovery and quantification. Incurred cookies were prepared at eight levels of milk contamination and were cooked to expose all milk components, including allergenic proteins, to food processing conditions. Remarkable results were obtained in term of sufficiently low LOD and LOQ (1.3 and 4 mg/kg cookies, respectively). Precision was calculated as intra-day repeatability (RSD in the 5-20% range) and inter-day repeatability (4 days; RSD never exceeded 12%). The extraction recovery values ranged from 20% to 26%. Method applicability was evaluated by analysing commercial cookies labelled either as "milk-free" or "may contain milk". Although the ELISA methodology is considered the gold standard for detecting allergens in foods, this robust LC-MS/MS approach should be a useful confirmatory method for assessing and certifying "milk-free" food products. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modi, Ketan Pravinbhai; Patel, Natvarlal Manilal; Goyal, Ramesh Kishorilal
2008-03-01
A selective, precise, and accurate high-performance thin-layer chromatographic (HPTLC) method has been developed for the analysis of L-dopa in Mucuna pruriens seed extract and its formulations. The method involves densitometric evaluation of L-dopa after resolving it by HPTLC on silica gel plates with n-butanol-acetic acid-water (4.0+1.0+1.0, v/v) as the mobile phase. Densitometric analysis of L-dopa was carried out in the absorbance mode at 280 nm. The relationship between the concentration of L-dopa and corresponding peak areas was found to be linear in the range of 100 to 1200 ng/spot. The method was validated for precision (inter and intraday), repeatability, and accuracy. Mean recovery was 100.30%. The relative standard deviation (RSD) values of the precision were found to be in the range 0.64-1.52%. In conclusion, the proposed TLC method was found to be precise, specific and accurate and can be used for identification and quantitative determination of L-dopa in herbal extract and its formulations.
[Comparative data regarding two HPLC methods for determination of isoniazid].
Gârbuleţ, Daniela; Spac, A F; Dorneanu, V
2009-01-01
For the determination of isoniazide (isonicotinic acid hydrazide - HIN) two different HPLC methods were developed and validated. Both experiments were performed using a Waters 2695 liquid chromatograph and a UV - Waters 2489 detector. The first method (I) used a Nucleosil 100-10 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of acetonitrile/10(-2) M oxalic acid (80/20) and a flow of 1.5 mL/ min; detection was done at 230 nm. The second method (II) used a Luna 100-5 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of methanol/acetate buffer, pH = 5.0 (20/ 80), a flow of 1 mL/min; detection was done at 270 nm. Both methods were validated, the correlation coefficients were 0.9998 (I) and 0.9999 (II), the detection limits were 0.6 microg/mL (I) and 0.055 microg/mL (II), the quantitation limits were 1.9 microg/mL (I) and 0.2 microg/ mL (II). There were also studied: the system precision (RSD = 0.1692% (I) and 0.2000% (II)), the method precision (RSD = 1.1844% (I) and 0.6170% (II)) and the intermediate precision (RSD = 1.8058% (I) and 0.5970% (II)). The accuracy was good, the calculated recoveries were 102.66% (I) and 101.36 (II). Both validated methods were applied for HIN determination from tablets with good and comparable results.
Hopkins, D L; Safari, E; Thompson, J M; Smith, C R
2004-06-01
A wide selection of lamb types of mixed sex (ewes and wethers) were slaughtered at a commercial abattoir and during this process images of 360 carcasses were obtained online using the VIAScan® system developed by Meat and Livestock Australia. Soft tissue depth at the GR site (thickness of tissue over the 12th rib 110 mm from the midline) was measured by an abattoir employee using the AUS-MEAT sheep probe (PGR). Another measure of this thickness was taken in the chiller using a GR knife (NGR). Each carcass was subsequently broken down to a range of trimmed boneless retail cuts and the lean meat yield determined. The current industry model for predicting meat yield uses hot carcass weight (HCW) and tissue depth at the GR site. A low level of accuracy and precision was found when HCW and PGR were used to predict lean meat yield (R(2)=0.19, r.s.d.=2.80%), which could be improved markedly when PGR was replaced by NGR (R(2)=0.41, r.s.d.=2.39%). If the GR measures were replaced by 8 VIAScan® measures then greater prediction accuracy could be achieved (R(2)=0.52, r.s.d.=2.17%). A similar result was achieved when the model was based on principal components (PCs) computed from the 8 VIAScan® measures (R(2)=0.52, r.s.d.=2.17%). The use of PCs also improved the stability of the model compared to a regression model based on HCW and NGR. The transportability of the models was tested by randomly dividing the data set and comparing coefficients and the level of accuracy and precision. Those models based on PCs were superior to those based on regression. It is demonstrated that with the appropriate modeling the VIAScan® system offers a workable method for predicting lean meat yield automatically.
Quantitative angle-insensitive flow measurement using relative standard deviation OCT.
Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping
2017-10-30
Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .
Quantitative angle-insensitive flow measurement using relative standard deviation OCT
NASA Astrophysics Data System (ADS)
Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping
2017-10-01
Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.
Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where themore » importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).« less
Yehia, Ali Mohamed; Essam, Hebatallah Mohamed
2016-09-01
A generally applicable high-performance liquid chromatographic method for the qualitative and quantitative determination of pharmaceutical preparations containing phenylephrine hydrochloride, paracetamol, ephedrine hydrochloride, guaifenesin, doxylamine succinate, and dextromethorphan hydrobromide is developed. Optimization of chromatographic conditions was performed for the gradient elution using different buffer pH values, flow rates and two C18 stationary phases. The method was developed using a Kinetex® C18 column as a core-shell stationary phase with a gradient profile using buffer pH 5.0 and acetonitrile at 2.0 mL/min flow rate. Detection was carried out at 220 nm and linear calibrations were obtained for all components within the studied ranges. The method was fully validated in agreement with ICH guidelines. The proposed method is specific, accurate and precise (RSD% < 3%). Limits of detection are lower than 2.0 μg/mL. Qualitative and quantitative responses were evaluated using experimental design to assist the method robustness. The method was proved to be highly robust against 10% change in buffer pH and flow rate (RSD% < 10%), however, the flow rate may significantly influence the quantitative responses of phenylephrine, paracetamol, and doxylamine (RSD% > 10%). Satisfactory results were obtained for commercial combinations analyses. Statistical comparison between the proposed chromatographic and official methods revealed no significant difference. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Shujuan; Zhao, Qingyan; Jiang, Xuejun; Yang, Bo; Dai, Zixuan; Wang, Xiaozhan; Wang, Xule; Guo, Zongwen; Yu, Shengbo; Tang, Yanhong; Hu, Wei; Huang, Congxin
2015-04-14
To explore the effects of renal sympathetic denervation (RSD) on pulmonary vascular remodeling in a model of pulmonary arterial hypertension (PAH). According to the random number table, 24 beagles were randomized into control, PAH and PAH+RSD groups (n=8 each). The levels of neurohormone, echocardiogram and dynamics parameters were measured. Then 0.1 ml/kg dimethylformamide (control group) or 2 mg/kg dehydromonocrotaline (PAH and PAH+RSD groups) were injected. The PAH+RSD group underwent RSD after injection. At week 8 post-injection, the neurohormone levels, echocardiogram, dynamics parameters and pulmonary tissue morphology were observed. The values of right ventricular systolic pressure (RVSP) and pulmonary arterial systolic pressure (PASP) in PAH and PAH+RSD groups were both significantly higher than those in control group ((42.8±8.7), (30.8±6.8) vs (23.2±5.7) mmHg (1 mmHg=0.133 kPa) and (45.1±11.2), (32.6±7.9) vs (24.7±7.1) mmHg). Meanwhile, the values of RVSP and PASP in PAH group were higher than those in PAH+RSD group (all P<0.01). The levels of serum angiotensin II (Ang II) and endothelin-1 significantly increased after 8 weeks in PAH dogs ((228±41) vs (113±34) pg/ml and (135±15) vs (77±7) pg/ml, all P<0.01). And Ang II and endothelin-1 were higher in lung tissues of PAH group ((65±10) and (96±10) pg/ml) than in those of control group ((38±7) and (54±6) pg/ml) and PAH+RSD group ((46±8) and (67±9) pg/ml) (all P<0.01). Pulmonary tissues had marked collagen hyperplasia and lamellar corpuscles of type 2 alveolar cells were damaged more severely in PAH dogs than in PAH+RSD dogs. RSD suppresses pulmonary vascular remodeling and decreases pulmonary arterial pressure in experimental PAH. And the effect of RSD on PAH may contribute to decreased neurohormone levels.
Zhang, Wen; Hu, Zhaochu; Günther, Detlef; Liu, Yongsheng; Ling, Wenli; Zong, Keqing; Chen, Haihong; Gao, Shan
2016-12-15
In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204 Hg on 204 Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20x Pb/ 204 Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20x Pb/ 206 Pb and <0.06% (RSD, k = 2) for 20x Pb/ 204 Pb with the exception of 20x Pb/ 204 Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 μg g -1 ) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 μg g -1 ). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol. Copyright © 2016 Elsevier B.V. All rights reserved.
Millán, S; Sampedro, M C; Unceta, N; Goicolea, M A; Rodríguez, E; Barrio, R J
2003-05-02
A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.
Graphene-metallic nanocomposites as modifiers in electrochemical glucose biosensor transducers
NASA Astrophysics Data System (ADS)
Altuntas, Derya Bal; Tepeli, Yudum; Anik, Ulku
2016-09-01
Graphene sheets and three different graphene-metallic nanocomposites including graphene-copper (graphene-Cu), graphene-nickel (graphene-Ni) and graphene-platinum (graphene-Pt) were prepared and characterized in the first place. Then the electrochemical performances of these nanocomposites were tested in glucose biosensor transducers, which were formed by combining these metallic nanocomposites with glucose oxidase enzyme and glassy carbon paste electrode (GCPE). This is the first work that includes the usage of these graphene-Me nanocomposites as a part of glucose biosensor transducer. Fabricated amperometric biosensors linear ranges were obtained as follow: For the plain graphene, the linear range was found in the concentration range between 50 μM and 800 μM with the RSD (n = 3 for 50 μM glucose) value of 12.86% and LOD value of 7.2 μM. For graphene-Pt modified glucose biosensor, the linear range was between 10 μM and 600 μM with the RSD (n = 3 for 50 μM glucose) value of 3.45% and LOD value of 3.06 μM. In the case of graphene-Ni modified glucose biosensor, the values were 25 μM to 600 μM with the RSD (n = 3 for 50 μM glucose) value of 8.76% and LOD value of 24.71 μM and for graphene-Cu modified glucose biosensor linear range was 25 μM to 400 μM with the RSD (n = 3 for 50 μM glucose) value of 3.93% and LOD value of 2.87 μM.
Predictors of Renal Denervation Efficacy in the Treatment of Resistant Hypertension.
Ripp, Tatiana M; Mordovin, Victor F; Pekarskiy, Stanislav E; Ryabova, Tamara R; Zlobina, Marina V; Baev, Andrei E; Anfinogenova, Yana; Popov, Sergey V
2015-12-01
The aims of the study were to evaluate the effects of renal sympathetic denervation (RSD) on the heart and to identify the predictors of RSD efficacy in patients with resistant arterial hypertension. The study comprised 60 RSD patients (54.6 ± 9.5 years) who received full-dose antihypertensive therapy (4.1 drugs) including diuretics. Initially, 58.6% of patients had abnormal left ventricular (LV) diastolic function. All patients received echocardiography before and 24 weeks after RSD. Renal sympathetic denervation was achieved through the endovascular radiofrequency ablation (RFA) of the renal arteries. Drug therapy continued for the entire period of observation. After RSD, all patients were retrospectively assigned to two groups: group 1 comprised patients (n = 22; 36.7%) in whom the myocardial mass (MM) of the left ventricle decreased by more than 10 g after RSD; group 2 comprised patients (n = 38; 63.3%) in whom LV MM increased or decreased by less than 10 g. Anthropometry, arterial blood pressure, heart rate, therapy, and LV end-diastolic dimensions (EDD) were comparable in these groups. After RSD, the values of office blood pressure significantly decreased and MM regressed by more than 10 g in 36.7% of patients; LV diastolic function normalized in 31% of patients, and diastolic dysfunction improved in 14% of patients. The study found the associations between the initial LV wall dimensions and LV MM changes. Unlike LV EDD, arterial blood pressure, or heart rate, the initial values of LV wall thickness predicted LV MM regress. #NCT01499810 https://clinicaltrials.gov/ct2/show/NCT01499810.
Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
Tandon, Shishir; Kumar, Satyendra; Sand, N. K.
2015-01-01
This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L−1 with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL−1 and 0.05 ng g−1, respectively. Good linearity (R 2 = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L−1. Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. PMID:25733978
Argekar, A P; Powar, S G
2000-01-01
A new simple, precise, rapid and selective high-performance thin-layer chromatographic (HPTLC) method has been developed for the simultaneous determination of atenolol (ATL) and amlodipine (AMLO) in tablets, using methylene chloride:methanol:ammonia solution (25% NH3) (8.8:1.3:0.1; v/v) as the mobile phase and Merck HPTLC plates (0.2 mm thickness) precoated with 60F254 silica gel on aluminium sheet as the stationary phase. Detection was carried out densitometrically using a UV detector at 230 nm. The retention factors of ATL and AMLO were 0.33 and 0.75, respectively. Calibration curves were linear in the range 10-500 microg ml(-1) for both. Assays of ATL and AMLO were 49.87 mg per tablet (relative standard deviation (R.S.D.), 1.3%) and 4.90 mg per tablet (R.S.D., 1.38%) for brand I, and 49.27 mg per tablet (R.S.D., 1.12%) and 4.98 mg per tablet (R.S.D., 1.42%) for brand II, respectively. The percentage recoveries for ATL and AMLO for brands I and II were 99.06 and 99.30%, and 99.27 and 99.15%, respectively.
Dörr, Oliver; Ewen, Sebastian; Liebetrau, Christoph; Möllmann, Helge; Gaede, Luise; Linz, Dominik; Hohl, Mathias; Troidl, Christian; Bauer, Timm; Böhm, Michael; Hamm, Christian; Mahfoud, Felix; Nef, Holger
2015-12-01
Renal sympathetic denervation (RSD) represents a safe and effective treatment option for certain patients with resistant hypertension and has been shown to decrease sympathetic activity. Neuropeptide Y (NPY) is a neurotransmitter that is co-released with norepinephrine and is up-regulated during increased sympathetic activity. The aim of the present study was to examine the effect of RSD on NPY and to analyze the association between changes in NPY levels and blood pressure reduction after RSD. A total of 150 consecutive patients (age 64.9 ± 10.2 years) from three clinical centers undergoing RSD were included in this study. Response to RSD was defined as an office systolic blood pressure (SBP) reduction of >10 mmHg 6 months after RSD. Venous blood samples for measurement of NPY were collected prior to and 6 months after RSD. BP and NPY levels were significantly reduced by 23/9 mmHg (p = 0.001/0.001) and 0.24 mg/dL (p < 0.01) 6 months after RSD. There was a significant correlation between baseline SBP- and RSD-related systolic BP reduction (r = -0.43; p < 0.001) and between serum NPY baseline values and NPY level changes (r = -0.52; p < 0.001) at the 6-month follow-up. The BP response to RSD (>10 mmHg) was associated with a significantly greater reduction in NPY level when compared with BP non-responders (p = 0.001). This study demonstrates an effect of RSD on serum NPY levels, a specific marker for sympathetic activity. The association between RSD-related changes in SBP and NPY levels provides further evidence of the effect of RSD on the sympathetic nervous system.
D'Autry, Ward; Zheng, Chao; Bugalama, John; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Wang, Bochu; Van Schepdael, Ann
2011-07-15
Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1μg/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat(®) sample batches. Copyright © 2011 Elsevier B.V. All rights reserved.
Semiautomated solid-phase extraction manifold with a solvent-level sensor.
Orlando, R M; Rath, S; Rohwedder, J J R
2013-11-15
A semiautomated solid-phase extraction manifold for multiple extractions is presented. The manifold utilizes commercial solid-phase syringe cartridges and automatically introduces and elutes all the solvents during the extraction, reducing the typical workload and stress of the analyst. The manifold consists of a peristaltic pump with solenoid valves in a flow circuit that contains transmissive photomicrosensors. The photomicrosensors were used to control the solvent dispenser and the solvent level inside the cartridge. As solvent-level sensors, the photomicrosensors determined the exact time the solvent reached the top frit to avoid sorbent drying and accurately perform the solvent exchange. The repeatability of the manifold to introduce a particular volume of solvent into the cartridges was measured, and the precisions were between 0.05 and 2.89% (RSD). To evaluate the manifold, the amount of two fluoroquinolones in a fortified blank milk sample was determined. The results of the intra- and inter-day precision of multiple extractions from the fortified milk samples resulted in precisions better than 9.0% (RSD) and confirmed that the arrangement of the semiautomated manifold could adequately be used in solid-phase extraction with commercial cartridges. Copyright © 2013 Elsevier B.V. All rights reserved.
Kraemer, T.F.; Doughten, M.W.; Bullen, T.D.
2002-01-01
A method is described that allows precise determination of 234U/238U activity ratios (UAR) in most natural waters using commonly available inductively coupled plasma/mass spectrometry (ICP/MS) instrumentation and accessories. The precision achieved by this technique (??0.5% RSD, 1 sigma) is intermediate between thermal ionization mass spectrometry (??0.25% RSID, 1 sigma) and alpha particle spectrometry (??5% RSD, 1 sigma). It is precise and rapid enough to allow analysis of a large number of samples in a short period of time at low cost using standard, commercially available quadrupole instrumentation with ultrasonic nebulizer and desolvator accessories. UARs have been analyzed successfully in fresh to moderately saline waters with U concentrations of from less than 1 ??g/L to nearly 100 ??g/L. An example of the uses of these data is shown for a study of surface-water mixing in the North Platte River in western Nebraska. This rapid and easy technique should encourage the wider use of uranium isotopes in surface-water and groundwater investigations, both for qualitative (e.g. identifying sources of water) and quantitative (e.g. determining end-member mixing ratios purposes.
Ring, P R; Bostick, J M
2000-04-01
A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.
Zhou, Qina; Zhou, Xianhui; TuEr-Hong, ZuKe-la; Wang, Hongli; Yin, Tingting; Li, Yaodong; Zhang, Ling; Lu, Yanmei; Xing, Qiang; Zhang, Jianghua; Yang, Yining; Tang, Baopeng
2016-01-15
This study aims to explore the effects of renal sympathetic denervation (RSD) on atrial fibrillation (AF) inducibility and sympathetic activity induced by acute atrial ischemia/infarction. Acute ischemia/infarction was induced in 12 beagle dogs by ligating coronary arteries that supply the atria. Six dogs in the sham-RSD group did not undergo RSD, and six dogs without coronary artery ligation served as controls. AF induction rate, sympathetic discharge, catecholamine concentration and densities of tyrosine hydroxylase-positive nerves were measured. Acute atrial ischemia/infarction resulted in a significant increase of AF induction rate, which was decreased by RSD compared to controls (P<0.05). The root-mean-square peak value, peak area and number of sympathetic discharges were significantly augmented by atrial ischemia relative to the baseline and control (P<0.05). The number of sympathetic discharges was significantly reduced in the RSD group, compared to the control and sham-RSD groups (P<0.05). Norepinephrine and epinephrine concentrations in the atria, ventricle and kidney were elevated by atrial ischemia/infarction, but were reduced by RSD (P<0.05). Sympathetic hyperactivity was associated with pacing-induced AF after acute atrial ischemia/infarction. RSD has the potential to reduce the incidence of new-onset AF after acute atrial ischemia/infarction. The inhibition of cardiac sympathetic activity by RSD may be one of the major underlying mechanisms for the marked reduction of AF inducibility. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Development of a screening method for the determination of forty-nine priority pollutants in soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiang, P.H.T.
1985-01-01
An extraction procedure followed by capillary GC-MS analysis was used to determine soil pollutants. Dual pH solutions with methylene chloride were used as extraction solvent system. Both base/neutral and acidic fractions were analyzed on the same fused silica 30 meter SPB-1 (SE-30) column. A GC-FID with a 60 meter wide-bore SPB-1 glass capillary column was used for quantitative analysis due to its larger sample capacity and higher sensitivity. The precision and accuracy for 5.1 ppm (51 ..mu..g/10 g) concentration in zero soil was less than 25% RSD. A headspace technique was also developed for the determination of volatile compounds. Themore » same instrumental conditions and columns were used as in the extraction procedure. The precision and accuracy for 3 grams soil sample spiked with 5.1 ppm (52 ..mu..g/10 mL) pollutant mixture in a 20 mL vial was less than 3% RSD.« less
McLain, B.J.
1993-01-01
Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.
Extension of the validation of AOAC Official Method 2005.06 for dc-GTX2,3: interlaboratory study.
Ben-Gigirey, Begoña; Rodríguez-Velasco, María L; Gago-Martínez, Ana
2012-01-01
AOAC Official Method(SM) 2005.06 for the determination of saxitoxin (STX)-group toxins in shellfish by LC with fluorescence detection with precolumn oxidation was previously validated and adopted First Action following a collaborative study. However, the method was not validated for all key STX-group toxins, and procedures to quantify some of them were not provided. With more STX-group toxin standards commercially available and modifications to procedures, it was possible to overcome some of these difficulties. The European Union Reference Laboratory for Marine Biotoxins conducted an interlaboratory exercise to extend AOAC Official Method 2005.06 validation for dc-GTX2,3 and to compile precision data for several STX-group toxins. This paper reports the study design and the results obtained. The performance characteristics for dc-GTX2,3 (intralaboratory and interlaboratory precision, recovery, and theoretical quantification limit) were evaluated. The mean recoveries obtained for dc-GTX2,3 were, in general, low (53.1-58.6%). The RSD for reproducibility (RSD(r)%) for dc-GTX2,3 in all samples ranged from 28.2 to 45.7%, and HorRat values ranged from 1.5 to 2.8. The article also describes a hydrolysis protocol to convert GTX6 to NEO, which has been proven to be useful for the quantification of GTX6 while the GTX6 standard is not available. The performance of the participant laboratories in the application of this method was compared with that obtained from the original collaborative study of the method. Intralaboratory and interlaboratory precision data for several STX-group toxins, including dc-NEO and GTX6, are reported here. This study can be useful for those laboratories determining STX-group toxins to fully implement AOAC Official Method 2005.06 for official paralytic shellfish poisoning control. However the overall quantitative performance obtained with the method was poor for certain toxins.
Cahill, Michael G; Dineen, Brian A; Stack, Mary A; James, Kevin J
2012-12-28
Acidic pesticide and pharmaceutical contaminants were pre-concentrated and extracted from wastewater samples (500 mL) using solid-phase extraction. Analyte recoveries were 79-96%, with % RSD values in the range, 1.7-7.4%. Analyte identification and quantification were carried out using liquid chromatography-mass spectrometry (LC-MS) with hybrid linear ion trap (LIT) Orbitrap instrumentation. Using a resolution setting of 30,000 FWHM, full-scan MS analysis was performed using heated electrospray ionization (HESI) in negative mode. The high mass resolution capabilities of the Orbitrap MS were exploited for the determination of trace contaminants allowing facile discrimination between analytes and matrix. The dependant scan functions of the Orbitrap MS using higher collisional dissociation (HCD) and LIT MS were evaluated for the confirmation of analytes at trace concentration levels. Mass accuracy for target contaminants using this method was less than 2 ppm. The limits of quantitation (LOQs) were in the range, 2.1-27 ng/L. The inter-day accuracy and precision were measured over a five-day period at two concentrations. The % relative errors were in the range, 0.30-7.7%, and the % RSD values were in the range, 1.5-5.5%. Using this method, 2,4-D, mecoprop, ibuprofen, naproxene and gemfibrozil were identified in several wastewater treatment plants in Ireland. Copyright © 2012 Elsevier B.V. All rights reserved.
Dzurko, Mark; Foucher, Delphine; Hintelmann, Holger
2009-01-01
MeHg and inorganic Hg compounds were measured in aqueous media for isotope ratio analysis using aqueous phase derivatization, followed by purge-and-trap preconcentration. Compound-specific isotope ratio measurements were performed by gas chromatography interfaced to MC-ICP/MS. Several methods of calculating isotope ratios were evaluated for their precision and accuracy and compared with conventional continuous flow cold vapor measurements. An apparent fractionation of Hg isotopes was observed during the GC elution process for all isotope pairs, which necessitated integration of signals prior to the isotope ratio calculation. A newly developed average peak ratio method yielded the most accurate isotope ratio in relation to values obtained by a continuous flow technique and the best reproducibility. Compound-specific isotope ratios obtained after GC separation were statistically not different from ratios measured by continuous flow cold vapor measurements. Typical external uncertainties were 0.16 per thousand RSD (n = 8) for the (202)Hg(/198)Hg ratio of MeHg and 0.18 per thousand RSD for the same ratio in inorganic Hg using the optimized operating conditions. Using a newly developed reference standard addition method, the isotopic composition of inorganic Hg and MeHg synthesized from this inorganic Hg was measured in the same run, obtaining a value of delta (202)Hg = -1.49 +/- 0.47 (2SD; n = 10). For optimum performance a minimum mass of 2 ng per Hg species should be introduced onto the column.
Quality control of test iodine in urine by spectrophotometry UV-Vis
NASA Astrophysics Data System (ADS)
Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri
2017-12-01
A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.
NASA Astrophysics Data System (ADS)
El-Zaher, Asmaa A.; Elkady, Ehab F.; Elwy, Hanan M.; Saleh, Mahmoud Abo El Makarim
2017-07-01
In the present work, pioglitazone and glimepiride, 2 widely used antidiabetics, were simultaneously determined by a chemometric-assisted UV-spectrophotometric method which was applied to a binary synthetic mixture and a pharmaceutical preparation containing both drugs. Three chemometric techniques - Concentration residual augmented classical least-squares (CRACLS), principal component regression (PCR), and partial least-squares (PLS) were implemented by using the synthetic mixtures containing the two drugs in acetonitrile. The absorbance data matrix corresponding to the concentration data matrix was obtained by the measurements of absorbencies in the range between 215 and 235 nm in the intervals with Δλ = 0.4 nm in their zero-order spectra. Then, calibration or regression was obtained by using the absorbance data matrix and concentration data matrix for the prediction of the unknown concentrations of pioglitazone and glimepiride in their mixtures. The described techniques have been validated by analyzing synthetic mixtures containing the two drugs showing good mean recovery values lying between 98 and 100%. In addition, accuracy and precision of the three methods have been assured by recovery values lying between 98 and 102% and R.S.D. % ˂0.6 for intra-day precision and ˂1.2 for inter-day precision. The proposed chemometric techniques were successfully applied to a pharmaceutical preparation containing a combination of pioglitazone and glimepiride in the ratio of 30: 4, showing good recovery values. Finally, statistical analysis was carried out to add a value to the verification of the proposed methods. It was carried out by an intrinsic comparison between the 3 chemometric techniques and by comparing values of present methods with those obtained by implementing reference pharmacopeial methods for each of pioglitazone and glimepiride.
Li, Hang; He, Junting; Liu, Qin; Huo, Zhaohui; Liang, Si; Liang, Yong
2011-03-01
A tandem solid-phase extraction method (SPE) of connecting two different cartridges (C(18) and MCX) in series was developed as the extraction procedure in this article, which provided better extraction yields (>86%) for all analytes and more appropriate sample purification from endogenous interference materials compared with a single cartridge. Analyte separation was achieved on a C(18) reversed-phase column at the wavelength of 265 nm by high-performance liquid chromatography (HPLC). The method was validated in terms of extraction yield, precision and accuracy. These assays gave mean accuracy values higher than 89% with RSD values that were always less than 3.8%. The method has been successfully applied to plasma samples from rats after oral administration of target compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M
2018-07-20
Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluating the precision of passive sampling methods using ...
To assess these models, four different thicknesses of low-density polyethylene (LDPE) passive samplers were co-deployed for 28 days in the water column at three sites in New Bedford Harbor, MA, USA. Each sampler was pre-loaded with six PCB performance reference compounds (PRCs) to assess equilibrium status, such that the percent of PRC lost would range depending on PRC and LDPE thickness. These data allow subsequent Cfree comparisons to be made in two ways: (1) comparing Cfree derived from one thickness using different models and (2) comparing Cfree derived from the same model using different thicknesses of LDPE. Following the deployments, the percent of PRC lost ranged from 0-100%. As expected, fractional equilibrium decreased with increasing PRC molecular weight as well as sampler thickness. Overall, a total of 27 PCBs (log KOW ranging from 5.07 – 8.09) were measured at Cfree concentrations varying from 0.05 pg/L (PCB 206) to about 200 ng/L (PCB 28) on a single LDPE sampler. Relative standard deviations (RSDs) for total PCB measurements using the same thickness and varying model types range from 0.04-12% and increased with sampler thickness. Total PCB RSD for measurements using the same model and varying thickness ranged from: 6 – 30%. No RSD trends between models were observed but RSD did increase as Cfree decreased. These findings indicate that existing models yield precise and reproducible results when using LDPE and PRCs to measure Cfree. This work in
Determination of saponins and flavonoids in ivy leaf extracts using HPLC-DAD.
Yu, Miao; Shin, Young June; Kim, Nanyoung; Yoo, Guijae; Park, SeonJu; Kim, Seung Hyun
2015-04-01
A new method for the determination of six compounds, chlorogenic acid, rutin, nicotiflorin, hederacoside C, hederasaponin B and α-hederin, in ivy leaf extracts using high-performance liquid chromatography with diode array detector was developed. The chromatographic separation was performed on a YMC Hydrosphere C18 analytical column using a gradient elution of 0.1% phosphoric acid and acetonitrile. The method was validated in terms of specificity, linearity (r(2) > 0.9999), precision [relative standard deviation (RSD) < 0.36%] and accuracy (97.4-103.8%). The limit of detection and limit of quantification were <20.32 and 61.56 ng for all analytes, respectively. The tested compounds were found to be stable in the ivy leaf extract from 0 to 48 h, and the RSD value for each compound was <0.90%. The validated method was successfully applied to quantify all six compounds in a 30% ethanol ivy leaf extract and 13 ivy leaf extract products. The results showed that all the tested products satisfied the minimum requirement for the content of hederacoside C. However, there were some differences between the contents of other constituents. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bonfilio, Rudy; Tarley, César Ricardo Teixeira; Pereira, Gislaine Ribeiro; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim
2009-11-15
This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 2(5-1) fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L(-1))-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min(-1). An octylsilane column (100 mm x 4.6mm i.d., 5 microm) maintained at 35 degrees C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r=0.9998) over a concentration range from 30 to 70 mg L(-1) of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L(-1), respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.
Darwish, Ibrahim A; Al-Obaid, Abdul-Rahman M; Al-Malaq, Hamoud A
2009-11-15
For the first time, an enzyme-linked immunosorbent assay (ELISA) has been developed and validated for the determination of fluvastatin (FLV) in plasma samples at picogram level. The assay employed a polyclonal antibody that specifically recognizes FLV with high affinity, and FLV conjugate of bovine serum albumin (FLV-BSA) immobilized onto microplate wells as a solid-phase. The assay involved a competitive binding reaction between FLV, in plasma sample, and the immobilized FLV-BSA for the binding sites on a limited amount of the anti-FLV antibody. The bound anti-FLV antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG) and 3,3',5,5'-tetramethylbenzidine (TMB) as a substrate for the peroxidase enzyme. The concentration of FLV in the sample was quantified by its ability to inhibit the binding of the anti-FLV antibody to the immobilized FLV-BSA and subsequently the color intensity in the assay wells. The conditions for the proposed ELISA were investigated and the optimum conditions were employed in the determination of FLV in plasma samples. The assay limit of detection was 10 pg mL(-1) and the effective working range at relative standard deviations (RSD) of
Automation of ⁹⁹Tc extraction by LOV prior ICP-MS detection: application to environmental samples.
Rodríguez, Rogelio; Leal, Luz; Miranda, Silvia; Ferrer, Laura; Avivar, Jessica; García, Ariel; Cerdà, Víctor
2015-02-01
A new, fast, automated and inexpensive sample pre-treatment method for (99)Tc determination by inductively coupled plasma-mass spectrometry (ICP-MS) detection is presented. The miniaturized approach is based on a lab-on-valve (LOV) system, allowing automatic separation and preconcentration of (99)Tc. Selectivity is provided by the solid phase extraction system used (TEVA resin) which retains selectively pertechnetate ion in diluted nitric acid solution. The proposed system has some advantages such as minimization of sample handling, reduction of reagents volume, improvement of intermediate precision and sample throughput, offering a significant decrease of both time and cost per analysis in comparison to other flow techniques and batch methods. The proposed LOV system has been successfully applied to different samples of environmental interest (water and soil) with satisfactory recoveries, between 94% and 98%. The detection limit (LOD) of the developed method is 0.005 ng. The high durability of the resin and its low amount (32 mg), its good intermediate precision (RSD 3.8%) and repeatability (RSD 2%) and its high extraction frequency (up to 5 h(-1)) makes this method an inexpensive, high precision and fast tool for monitoring (99)Tc in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Dörr, Oliver; Liebetrau, Christoph; Möllmann, Helge; Gaede, Luise; Troidl, Christian; Morczeck, Kareen; Wiebe, Jens; Hoffmann, Jedrzej; Voss, Sandra; Bauer, Timm; Hamm, Christian; Nef, Holger
2015-10-01
Renal sympathetic denervation (RSD) represents an effective treatment option for patients with resistant arterial hypertension (HT). Extracellular matrix (ECM) turnover and deposition are essential processes in HT-related cardiovascular remodeling, fibrosis, and cardiac hypertrophy and contribute to hypertensive heart disease. The primary aim of the present study was to examine the effect of RSD on increased collagen turnover as reflected by serum levels of amino-terminal pro-peptides (PINP, PIIINP) and a carboxyl-terminal pro-peptide (PICP), specific biomarkers for cardiac ECM turnover and cardiovascular fibrosis. A total of 100 consecutive patients (mean age: 65.9±10.1 years) undergoing RSD were included in this study. A therapeutic response was defined as an office systolic blood pressure (SBP) reduction of >10mm Hg 6 months after RSD. Venous serum samples for measurement of PICP, PINP, and PIIINP were collected prior to and 6 months after RSD. A significant reduction in the office SBP of 24.3 mm Hg (SBP baseline: 166.9±14.3 mm Hg (P < 0.001) was documented 6 months after RSD. At this time point, the serum levels of PICP, PINP, and PIIINP (P < 0.01) were significantly decreased compared to baseline values in patients with an increased collagen turnover, showing significant differences comparing BP responders and nonresponders. In addition to the effective blood pressure reduction in response to RSD, this study demonstrates a positive effect of RSD on biomarkers reflecting cardiovascular ECM turnover and deposition. These results suggest a beneficial effect of RSD on cardiovascular fibrosis, hypertensive heart disease, and end-organ damage in high-risk patients. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dörr, Oliver; Liebetrau, Christoph; Möllmann, Helge; Gaede, Luise; Troidl, Christian; Wiebe, Jens; Renker, Matthias; Bauer, Timm; Hamm, Christian; Nef, Holger
2016-06-01
Previous studies of renal sympathetic denervation (RSD) excluded patients with impaired renal function to avoid potential RSD-related renal damage. Measurement of the highly sensitive biomarkers neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) has shown that RSD does not aggravate renal damage during the early post-procedural period. The aim of the present study was to examine the effect of RSD on blood pressure (BP) reduction and renal function after a long-term follow-up. A total of 62 consecutive patients undergoing RSD were included in this study. Serum NGAL and KIM-1 were collected prior to RSD and at 24 hr, 48 hr, and 3 months after RSD. BP measurements, antihypertensive medication use, and safety events were followed over a three-year period. Follow-up data were available over 36.9[±3.4] months in 47 of 62 (75.8%) of the initially included patients. At this time point a significant systolic BP reduction of 23 mm Hg (P > 0.001) was documented, and there were no significant changes in serum creatinine (P = 0.14), blood urea nitrogen (P = 0.33), or estimated glomerular filtration rate (eGFR) (P = 0.2) values. There were also no significant changes documented in patients with impaired renal function (eGFR < 45 mL/min) during the early post- procedural period or the long-term follow-up (P = 0.34). The results of the present study show a sustained effect of RSD on BP reduction after a three-year follow-up, and there was no evidence of renal failure. These results provide verification of the long-term safety and effectiveness of RSD, even in patients with impaired renal function. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Ribichini, Flavio; Ferrara, Angela; Pighi, Michele; Pesarini, Gabriele; Gambaro, Alessia; Valvo, Enrico; Lupo, Antonio; Vassanelli, Corrado
2014-12-01
Renal sympathetic denervation (RSD) is emerging as a new therapeutic option for patients with severe hypertension refractory to medical therapy. Patients affected by renovascular or anatomical abnormalities have hitherto been systematically excluded from clinical trials with RSD because of concern about safety and the unknown efficacy of the procedure in this subgroup of patients. We describe the management of a case of RSD in a single-kidney patient with refractory hypertension; the patient had had a previous surgical right nephrectomy for renal cell carcinoma that subsequently required no other oncologic treatment. After multidisciplinary assessment, the patient underwent RSD. The procedure was performed through a 6F femoral access using the Symplicity™ RSD system (Medtronic, Mountain View, CA, USA). Radiofrequency was applied to the renal artery wall in 6 different points under general sedation with midazolam to control back pain caused by the procedure, that was performed without periprocedural complications. The patient was discharged 2 days later after a control of the vascular access site and routine biochemical examinations. The following 9-month follow up showed a significant reduction in blood pressure and stable renal function, without signs of renal damage. Our report confirms the feasibility of RSD in this delicate context, without evident negative effects on kidney function and with a significant reduction in blood pressure. Future studies are needed to fully clarify the value of RSD in single-kidney patients.
NASA Astrophysics Data System (ADS)
Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.
2012-03-01
A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.
Ashfaq, Maria; Sial, Ali Akber; Bushra, Rabia; Rehman, Atta-Ur; Baig, Mirza Tasawur; Huma, Ambreen; Ahmed, Maryam
2018-01-01
Spectrophotometric technique is considered to be the simplest and operator friendly among other available analytical methods for pharmaceutical analysis. The objective of the study was to develop a precise, accurate and rapid UV-spectrophotometric method for the estimation of chlorpheniramine maleate (CPM) in pure and solid pharmaceutical formulation. Drug absorption was measured in various solvent systems including 0.1N HCl (pH 1.2), acetate buffer (pH 4.5), phosphate buffer (pH 6.8) and distil water (pH 7.0). Method validation was performed as per official guidelines of ICH, 2005. High drug absorption was observed in 0.1N HCl medium with λ max of 261nm. The drug showed the good linearity from 20 to 60μg/mL solution concentration with the correlation coefficient linear regression equation Y= 0.1853 X + 0.1098 presenting R 2 value of 0.9998. The method accuracy was evaluated by the percent drug recovery, presents more than 99% drug recovery at three different levels assessed. The % RSD value <1 was computed for inter and intraday analysis indicating the high accuracy and precision of the developed technique. The developed method is robust because it shows no any significant variation in with minute changes. The LOD and LOQ values were assessed to be 2.2μg/mL and 6.6μg/mL respectively. The investigated method proved its sensitivity, precision and accuracy hence could be successfully used to estimate the CPM content in bulk and pharmaceutical matrix tablets.
Microbiological assay for the determination of meropenem in pharmaceutical dosage form.
Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S
2005-04-01
Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.
Bassanese, Danielle N; Conlan, Xavier A; Barnett, Neil W; Stevenson, Paul G
2015-05-01
This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Spark ablation-inductively coupled plasma spectrometry for analysis of geologic materials
Golightly, D.W.; Montaser, A.; Smith, B.L.; Dorrzapf, A.F.
1989-01-01
Spark ablation-inductively coupled plasma (SA-ICP) spectrometry is applied to the measurement of hafnium-zirconium ratios in zircons and to the determination of cerium, cobalt, iron, lead, nickel and phosphorus in ferromanganese nodules. Six operating parameters used for the high-voltage spark and argon-ICP combination are established by sequential simplex optimization of both signal-to-background ratio and signal-to-noise ratio. The time-dependences of the atomic emission signals of analytes and matrix elements ablated from a finely pulverized sample embedded in a pressed disk of copper demonstrate selective sampling by the spark. Concentration ratios of hafnium to zirconium in zircons are measured with a precision of 4% (relative standard deviation, RSD). For ferromanganese nodules, spectral measurements based on intensity ratios of analyte line to the Mn(II) 257.610 nm line provide precisions of analysis in the range from 7 to 14% RSD. The accuracy of analysis depends on use of standard additions of the reference material USGS Nod P-1, and an independent measurement of the Mn concentration. ?? 1989.
Panda, Sagar Suman; Patanaik, Debasis; Ravi Kumar, Bera V. V.
2012-01-01
A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C18, Lichrosphere-100® (250 mm × 4.6 mm i.d., particle size 5 μm) column at room temperature in isocratic mode, the mobile phase consists of methanol: water (80:20, v/v) at a flow rate of 1.0 ml/min, the injection volume was 20 μl and UV detection was carried out at 280nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The method was linear in the drug concentration range of 2.5–30 μg/ml and 20–240 μg/ml for diclofenac potassium and metaxalone, respectively. The precision (RSD) of six samples was 0.83 and 0.93% for repeatability, and the intermediate precision (RSD) among six-sample preparation was 1.63 and 0.49% for diclofenac potassium and metaxalone, respectively. The mean recoveries were between 100.99–102.58% and 99.97–100.01% for diclofenac potassium and metaxalone, respectively. The proposed method can be used successfully for routine analysis of the drug in bulk and combined pharmaceutical dosage forms. PMID:22396909
Shawky, Eman; Sallam, Shaimaa M
2017-11-01
A new high-throughput method was developed for the simultaneous analysis of isoflavones and soyasaponnins in Soy (Glycine max L.) products by high-performance thin-layer chromatography with densitometry and multiple detection. Silica gel was used as the stationary phase and ethyl acetate:methanol:water:acetic acid (100:20:16:1, v/v/v/v) as the mobile phase. After chromatographic development, multi-wavelength scanning was carried out by: (i) UV-absorbance measurement at 265 nm for genistin, daidzin and glycitin, (ii) Vis-absorbance measurement at 650 nm for Soyasaponins I and III, after post-chromatographic derivatization with anisaldehyde/sulfuric acid reagent. Validation of the developed method was found to meet the acceptance criteria delineated by ICH guidelines with respect to linearity, accuracy, precision, specificity and robustness. Calibrations were linear with correlation coefficients of >0.994. Intra-day precisions relative standard deviation (RSD)% of all substances in matrix were determined to be between 0.7 and 0.9%, while inter-day precisions (RSD%) ranged between 1.2 and 1.8%. The validated method was successfully applied for determination of the studied analytes in soy-based infant formula and soybean products. The new method compares favorably to other reported methods in being as accurate and precise and in the same time more feasible and cost-effective. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun
2008-01-01
A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.
Du, Guangyan; Fu, Lingling; Jia, Jun; Pang, Xu; Yu, Haiyang; Zhang, Youcai; Fan, Guanwei; Gao, Xiumei; Han, Lifeng
2018-06-01
A rapid, sensitive and specific ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method was developed to investigate the pharmacokinetics and tissue distribution of Eclipta prostrata extract. Rats were orally administrated the 70% ethanol extract of E. prostrata, and their plasma as well as various organs were collected. The concentrations of seven main compounds, ecliptasaponin IV, ecliptasaponin A, apigenin, 3'-hydroxybiochanin A, luteolin, luteolin-7-O-glucoside and wedelolactone, were quantified by UPLC-MS/MS through multiple reactions monitoring method. The precisions (RSD) of the analytes were all <15.00%. The extraction recoveries ranged from 74.65 to 107.45% with RSD ≤ 15.36%. The matrix effects ranged from 78.00 to 118.06% with RSD ≤ 15.04%. To conclude, the present pharmacokinetic and tissue distribution studies provided useful information for the clinical usage of Eclipta prostrata L. Copyright © 2018 John Wiley & Sons, Ltd.
Mumtaz, Amina; Hussain, Shahid; Yasir, Muhammad
2014-09-01
A simple eco-friendly method has been developed for detection of hydroxyzine dihydrochloride in pure and pharmaceutical dosage forms. Both conventional system and microwave assisted procedures are used for the development of color. The blue coloured complex is measured spectrophotometrically at 750nm. Peak shift in FT-IR spectra also indicated the formation of complex. The reaction obeys Beer's law over the concentration range of 50- 250βg/mL of hydroxyzine dihydrochloride. The precision value (intra-day and inter-day RSD) for the drug is not greater than 0.79% and recoveries were found to be in range of 99.01-99.99%. The designed method is applicable for periodic determination of hydroxyzine dihydrochloride in pure and pharmaceutical dosage forms.
Shehzadi, Naureen; Hussain, Khalid; Islam, Muhammad; Bukhari, Nadeem Irfan; Asif, Noman; Khan, Muhammad Tanveer; Salman, Muhammad; Qamar, Shaista; Parveen, Sajida; Zahid, Fakhra; Shah, Arshad Ali; Bilal, Abida; Abbasi, Muhammad Athar; Siddiqui, Sabahat Zahra; Rehman, Azizur
2018-03-01
The present study describes the development and validation of a simple high performance liquid chromatographic method for the determination of a novel drug candidate, 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol. The stability-indicating capacity of the method was evaluated by subjecting the compound's solution to hydrolytic, oxidative, photolytic, transition metal- and thermal- stress. The chromatographic separation was achieved over a C18 column (Promosil, 5 µm, 4.60 × 250 mm), maintained at 25°C, using an isocratic mobile phase comprising a mixture of acetonitrile and acidified water of pH 2.67 (1:1, v/v), at a flow rate of 1.00 mL/min and detection using a fluorescent light detector (excitation at 250 nm and emission at 410 nm). The Beer's law was followed over the concentration range 2.50-50.00 μg/ml. The recovery (98.56-100.19%, SD <5%), intraday accuracy and precision (97.31-100.81%, RSD <5%), inter-day accuracy and precision (97.50-100.75%, RSD <5%) and intermediate accuracy and precision (98.10-99.91%, RSD <5%) indicated that the method was reliable, repeatable, reproducible and rugged. The resolution and selectivity factors of the compound's peak from the nearest resolving peak, particularly in case of dry heat and copper metal stress, were found to be greater than 2 and 1, respectively, which indicated specificity and selectivity. The compound was extensively decomposed in alkaline-hydrolytic, oxidative, metal- and dry heat- stress. However, the compound in acidic and neutral conditions was resistant to photolysis. The results of the present study indicate that the developed method is specific, selective, sensitive and suitable, hence, may be used for quality control, stability testing and preformulation studies.
DETERMINATION OF AZOXYSTROBIN AND DIFENOCONAZOLE IN PESTICIDE PRODUCTS.
Lazić, S; Šunjka, D
2015-01-01
In this study a high performance liquid chromatographic (HPLC-DAD) procedure has been developed for the simultaneous determination of azoxystrobin and difenoconazole in suspension concentrate pesticide formulations, with the aim of the product quality control. Azoxystrobin, strobilurin fungicide and difenoconazole (cis,trans-3-chloro-4-[4-methyl-2-(1H-1,2,4-triazol-1-ylmethyl)-1,3-dioxolan-2-yl]phenyl 4-chlorophenyl ether), triazole fungicide, are used for the protection of plants from wide spectrum of fungal diseases. For the analysis LC system an Agilent Technologies 1100 Series was used. Good separation was achieved on a Zorbax SB-C18 column (5 μm, 250 mm x 3 mm internal diameter) using a mobile phase consisting of acetonitrile/ultrapure water (90:10, v/v), at a flow rate of 0.9 ml/minute and UV detection at 218 nm. Column temperature was 25 degrees C, injected volume was 1 μl. Retention times for azoxystrobin and difenoconazole were 2.504 min and 1.963 min, respectively. This method is validated according to the requirements for new methods, which include linearity, precision, accuracy and selectivity. The method demonstrates good linearity with r2 > 0.997. The repeatability of the method, expressed as relative standard deviation (RSD, %), was found to be 1.9% for azoxystrobin and 0.5% for difenoconazole. The precision of the method was also considered to be acceptable as the experimental repeatability relative standard deviation (RSD) was lower than the RSD calculated using the Horwitz equation of 1.7% and 1.4% for azoxystrobin and difenoconazole, respectively. The accuracy of the proposed method was determined from recovery experiments through standard addition procedure. The average recoveries of the three fortification levels were 101.9% for azoxystrobin and 103.2% for difenoconazole with RSDs of 1.1% and 1.2%. The method described in this paper is simple, precise, accurate and selective and represents a new and reliable way of simultaneous determination of azoxystrobin and difenoconazole in formulated products.
Takabatake, Reona; Akiyama, Hiroshi; Sakata, Kozue; Onishi, Mari; Koiwa, Tomohiro; Futo, Satoshi; Minegishi, Yasutaka; Teshima, Reiko; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi
2011-01-01
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event; A2704-12. During the plant transformation, DNA fragments derived from pUC19 plasmid were integrated in A2704-12, and the region was found to be A2704-12 specific. The pUC19-derived DNA sequences were used as primers for the specific detection of A2704-12. We first tried to construct a standard plasmid for A2704-12 quantification using pUC19. However, non-specific signals appeared with both qualitative and quantitative PCR analyses using the specific primers with pUC19 as a template, and we then constructed a plasmid using pBR322. The conversion factor (C(f)), which is required to calculate the amount of the genetically modified organism (GMO), was experimentally determined with two real-time PCR instruments, the Applied Biosystems 7900HT and the Applied Biosystems 7500. The determined C(f) values were both 0.98. The quantitative method was evaluated by means of blind tests in multi-laboratory trials using the two real-time PCR instruments. The limit of quantitation for the method was estimated to be 0.1%. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSD(R)), and the determined bias and RSD(R) values for the method were each less than 20%. These results suggest that the developed method would be suitable for practical analyses for the detection and quantification of A2704-12.
Simultaneous analysis of eight bioactive compounds in Danning tablet by HPLC-ESI-MS and HPLC-UV.
Liu, Runhui; Zhang, Jiye; Liang, Mingjin; Zhang, Weidong; Yan, Shikai; Lin, Min
2007-02-19
A high performance liquid chromatography (HPLC) coupled with electrospray tandem mass spectrometry (ESI-MS) and ultraviolet detector (UV) has been developed for the simultaneous analysis of eight bioactive compounds in Danning tablet (including hyperin, hesperidin, resveratrol, nobiletin, curcumine, emodin, chrysophanol, and physcion), a widely used prescription of traditional Chinese medicine (TCM). The chromatographic separation was performed on a ZORBAX Extend C(18) analytical column by gradient elution with acetonitrile and formate buffer (containing 0.05% formic acid, adjusted with triethylamine to pH 5.0) at a flow rate of 0.8 ml/min. The eight compounds in Danning tablet were identified and their MS(n) fractions were elucidated by using HPLC-ESI-MS, and the contents of these compounds were determined by using HPLC-UV method. The standard calibration curves were linear between 5.0 and 100 microg/ml for hyperin, 10-200 microg/ml for hesperidin, 1.0-150 microg/ml for resveratrol, 2.0-120 microg/ml for nobiletin, 2.0-225 microg/ml for curcumine, 20-300 microg/ml for emodin, 2.0-200 microg/ml for chrysophanol, and 20-250 microg/ml for physcion with regression coefficient r(2)>0.9995. The intra-day and inter-day precisions of this method were evaluated with the R.S.D. values less than 0.7% and 1.3%, respectively. The recoveries of the eight investigated compounds were ranged from 99.3% to 100.2% with R.S.D. values less than 1.5%. This method was successfully used to determine the 8 target compounds in 10 batches of Danning tablet.
Sakuma, Hisako; Kamata, Yoichi; Sugita-Konishi, Yoshiko; Kawakami, Hiroshi
2011-01-01
A rapid, sensitive convenient method for determination of aflatoxin M₁ (AFM₁) in cheese and butter by HPLC was developed and validated. The method employs a safe extraction solution (mixture of acetonitrile, methanol and water) and an immunoaffinity column (IAC) for clean-up. Compared with the widely used method employing chloroform and a Florisil column, the IAC method has a short analytical time and there are no interference peaks. The limits of quantification (LOQ) of the IAC method were 0.12 and 0.14 µg/kg, while those of the Florisil column method were 0.47 and 0.23 µg/kg in cheese and buffer, respectively. The recovery and relative standard deviation (RSD) for cheese (spiked at 0.5 µg/kg) in the IAC method were 92% and 7%, respectively, while for the Florisil column method the corresponding values were 76% and 10%. The recovery and RSD for butter (spiked at 0.5 µg/kg) in the IAC method were 97% and 9%, and those in the Florisil method were 74% and 9%, respectively. In the IAC method, the values of in-house precision (n=2, day=5) of cheese and butter (spiked at 0.5 µg/kg) were 9% and 13%, respectively. The IAC method is superior to the Florisil column method in terms of safety, ease of handling, sensitivity and reliability. A survey of AFM₁ contamination in imported cheese and butter in Japan was conducted by the IAC method. AFM₁ was not detected in 60 samples of cheese and 30 samples of butter.
Gantait, Arunava; Maji, Amal; Barman, Tapu; Banerji, Pratim; Venkatesh, P; Mukherjee, Pulok K
2012-01-01
Capsicum annuum L. (family: Solanaceae) possesses therapeutic benefits for the treatment of rheumatism, neuropathy, psoriasis, flatulence and so on. In this study fruits of four different varieties of C. annuum from four different geographical regions in India were evaluated based on their total content of capsaicin. Ethanol extracts of the fruits were used. HPTLC plates were developed in a mobile phase containing benzene, ethyl acetate and methanol (75:20:5). Densitometric scanning was performed at a wavelength of 283 nm in the absorbance mode. The calibration curve was described by the equation Y=393.587+3.836*X with a correlation coefficient (r) of 0.99890. The content of capsaicin in Nagaland, Manipur, West Bengal and Shimla varieties was found to be 3.71%, 1.78%, 0.54% and 0.06%, respectively. The developed densitometric method was found to be specific, accurate and precise. A recovery study and precision showed low levels of %RSD values. The linearity range of the curve for capsaicin was found to be 300-900 ng per spot. The limit of detection and the limit of quantification values were determined to be 31 and 94 ng, respectively, proving the sensitivity of the method. Thus the method can be used to control the total content of capsaicin on an industrial scale.
Fujimori, Kiyoshi; Lee, Hans; Phillips, Joseph; Nashed-Samuel, Yasser
The European Pharmacopeia surface test to analyze the hydrolytic resistance is a common industrial method to understand and ensure the quality of produced glass vials. Hydrolytic resistance is evaluated by calculating the alkalinity of water extract from autoclaved vials by titration. As an alternative to this titration technique, a conductivity technique was assessed, which directly measures the ions in the water extract. A conductivity meter with a 12 mm diameter electrode was calibrated with a 100 μS/cm conductivity standard and carryover minimized by rinsing the probe in a water beaker per analysis. The limit of quantification at 1 μS/cm was determined as having a signal-to-noise ratio of 3 compared with the water blank. The conductivity method was selective for glass-composing elements (boron, sodium, aluminum, silicon, potassium, and calcium) within the vial extract. Accuracies of spiked conductivity standard within the range of 1 to 100 μS/cm were ±7% and had linearity with coefficient of determination (R 2 ) of ≥0.9999. Intraday precision had a relative standard deviation (RSD) (n = 5) of ≤6% for spiked conductivity standard within the range of 1 to 100 μS/cm. Interday precision had a RSD (n = 4) of ≤6% for 10 vials from three glass vial lots. Conductivity of water extracts from nine sets of seven lots of glass vials had a precise linear relationship [R 2 = 0.9876, RSD = 1% (n = 9)] with titration volumes of the same lots. Conductivity results in μS/cm could be converted to titration volumes in milliliters by a conversion factor of 0.0275. The simplicity, sample stability, and individual vial analysis of the conductivity technique were more advantageous than the current titration technique. The quality of glass vials used as primary containers in the pharmaceutical industry is of concern due to recent observations of glass flake-like delamination, or lamellae, under specific storage conditions. The current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. As an alternative to the European Pharmacopoeia method, the vial extracts were analyzed for conductivity, which directly determines the level of ions that were readily extracted from the vial surfaces. Lower quality glass would have greater surface defects that lead to higher ions extracted and higher conductivity value. The conductivity method was found to be suitable to measure the ions in water extracts and showed strong correlation with alkalinity. The advantage of the conductivity method over the alkalinity method was greater ease, lower volume requirements, stability, and flexibility in analysis. © PDA, Inc. 2017.
Multifamily determination of pesticide residues in soya-based nutraceutical products by GC/MS-MS.
Páleníková, Agneša; Martínez-Domínguez, Gerardo; Arrebola, Francisco Javier; Romero-González, Roberto; Hrouzková, Svetlana; Frenich, Antonia Garrido
2015-04-15
An analytical method based on a modified QuEChERS extraction coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS) was evaluated for the determination of 177 pesticides in soya-based nutraceutical products. The QuEChERS method was optimised and different extraction solvents and clean-up approaches were tested, obtaining the most efficient conditions with a mixture of sorbents (PSA, C18, GBC and Zr-Sep(+)). Recoveries were evaluated at 10, 50 and 100 μg/kg and ranged between 70% and 120%. Precision was expressed as relative standard deviation (RSD), and it was evaluated for more than 160 pesticides as intra and inter-day precision, with values always below 20% and 25%, respectively. Limits of detection (LODs) ranged from 0.1 to 10 μg/kg, whereas limits of quantification (LOQs) from 0.5 to 20 μg/kg. The applicability of the method was proved by analysing soya-based nutraceuticals. Two pesticides were found in these samples, malathion and pyriproxyfen, at 11.1 and 1.5 μg/kg respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Determination of tungsten and cobalt in the air of workplace by ICP-OES].
Zhang, J; Ding, C G; Li, H B; Song, S; Yan, H F
2017-08-20
Objective: To establish the inductively coupled plasma optical emission spectrometry (ICP-OES) method for determination of cobalt and tungsten in the air of workplace. Methods: The cobalt and tungsten were collected by filter membrane and then digested by nitric acid, inductively coupled plasma optical emission spectrometry (ICP-OES) was used for the detection of cobalt and tungsten. Results: The linearity of tungsten was good at the range of 0.01-1 000 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.006 7 μg/ml and 0.022 μg/ml, respectively. The recovery was ranged from 98%-101%, the RSD of intra-and inter-batch precision were 1.1%-3.0% and 2.1%-3.8%, respectively. The linearity of cobalt was good at the range of 0.01-100 μg/ml with a correlation coefficient of 0.999 9, the LOD and LOQ were 0.001 2 μg/ml and 0.044 μg/ml, respectively. The recovery was ranged from 95%-97%, the RSD of intra-and inter-batch precision were 1.1%-2.4% and 1.1%-2.9%, respectively. The sampling efficiency of tungsten and cobalt were higher than 94%. Conclusion: The linear range, sensitivity and precision of the method was suitable for the detection of tungsten and cobalt in the air of workplace.
NASA Astrophysics Data System (ADS)
Chaves-Montero, Jonás; Angulo, Raúl E.; Hernández-Monteagudo, Carlos
2018-04-01
In the upcoming era of high-precision galaxy surveys, it becomes necessary to understand the impact of redshift uncertainties on cosmological observables. In this paper we explore the effect of sub-percent photometric redshift errors (photo-z errors) on galaxy clustering and baryonic acoustic oscillations (BAO). Using analytic expressions and results from 1 000 N-body simulations, we show how photo-z errors modify the amplitude of moments of the 2D power spectrum, their variances, the amplitude of BAO, and the cosmological information in them. We find that: a) photo-z errors suppress the clustering on small scales, increasing the relative importance of shot noise, and thus reducing the interval of scales available for BAO analyses; b) photo-z errors decrease the smearing of BAO due to non-linear redshift-space distortions (RSD) by giving less weight to line-of-sight modes; and c) photo-z errors (and small-scale RSD) induce a scale dependence on the information encoded in the BAO scale, and that reduces the constraining power on the Hubble parameter. Using these findings, we propose a template that extracts unbiased cosmological information from samples with photo-z errors with respect to cases without them. Finally, we provide analytic expressions to forecast the precision in measuring the BAO scale, showing that spectro-photometric surveys will measure the expansion history of the Universe with a precision competitive to that of spectroscopic surveys.
Bernardy, Jeffry A.; Hubert, Terrance D.; Ogorek, Jacob M.; Schmidt, Larry J.
2013-01-01
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples ≥500 ng/L and 4.8 to 17% RSD with samples ≤100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
Bernardy, Jeffry A; Hubert, Terrance D; Ogorek, Jacob M; Schmidt, Larry J
2013-01-01
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples > or = 500 ng/L and 4.8 to 17% RSD with samples < or = 100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
Ding, X; Xu, X; Yan, Y; Song, X; Liu, S; Wang, G; Su, D; Jing, Q; Qin, Y
2015-06-01
The aim of this study was to investigate whether renal sympathetic denervation (RSD) is more effective on myocardial hypertrophy than the angiotensin-converting enzyme inhibitor (ACEI) perindopril in spontaneously hypertensive rats (SHRs). After bilateral renal denervation blood pressure (BP) was measured every 10 days. On day 50 the heart was (histo)pathologically examined. The ventricular weight to body weight ratios (VW/BW), myocardial diameter and collagen volume fraction (CVF) were calculated, and cardiac hypertrophy marker genes were analyzed by RT-PCR. At the baseline evaluation all groups had comparable BP. After treatment the BP of the RSD group was significantly reduced (p < 0.05). The BP of the RSD group was lower than that of the perindopril group on days 10, 20 and 30th (p < 0.05) but on day 50 systolic BP of the RSD group was significantly higher (p < 0.05) whereas there were no significant differences in diastolic BP. The VW/BW decreased in the RSD group, whereas the value did not change significantly in the perindopril group. The myocardial diameter of the left ventricular cardiomyocytes was also significantly lower in the RSD group and stayed the same in the perindopril group. Collagen volume fraction (CVF) in the RSD group was significantly lower than in the perindopril group (p < 0.05). Significant changes in the expression levels of NPPA, MYH7, and MYH6 (P < 0.05) were observed in the RD-SHR groups (p < 0.05). There was a significant difference in the expression level of MYH6 (p < 0.05) between the RSD group and the perindopril group but the expression levels of NPPA and MYH7 were not significantly different. In this study, RSD had a significant antihypertensive effect and inhibited hypertensive-induced cardiac hypertrophy in SHRs and showed advantages compared with ACEI in decreasing BP in the early stage and in inhibiting myocardial fibrosis.
Ji, Wei; Bi, Kaishun; Chen, Qianqian; Jiang, Lingyan; Liang, Ke; Li, Qing
2011-11-01
A simple, reliable and effective gas chromatography coupled with flame ionization detection method was developed for the simultaneous determination of eight components (α-pinene, β-pinene, myrcene, limonene, terpinen-4-ol, α-terpineol, bornyl acetate and methyl-n-nonylketone) in Chinese medicine Houttuynia cordata and its injection. The chromatographic separation of all eight components, including undecylene as internal standard was performed on a DB-1 column (30 m×0.25 mm, 0.25 μm). Excellent linear behaviors including herb and injection over the investigated concentration ranges were observed with the values of r(2) higher than 0.9990 for all analytes. Satisfactory intra-day and inter-day precisions were achieved with RSD less than 2% and the average recoveries for all analytes at three different concentrations obtained were in the range of 93.4-104.4%, with RSD ranging from 1.3 to 4.1%. The proposed method was successfully applied in the simultaneous determination of these active components in H. cordata and H. cordata injection (HCI), including the intermediate product of HCI in productive process, from different pharmaceutical factories and different production batches, indicating that the method in this paper was particularly suitable for the routine analysis of HCI and its quality control in productive process. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bürger, Stefan; Riciputi, Lee R; Bostick, Debra A
A ThermoFisher 'Triton' multi-collector thermal ionization mass spectrometer (MC-TIMS) was evaluated for trace and ultra-trace level isotoperatioanalysis of actinides (uranium, plutonium, and americium), fission products and geolocators (strontium, cesium, and neodymium). Total efficiencies (atoms loaded to ions detected) of up to 0.5-2% for U, Pu, and Am, and 1-30% for Sr, Cs, and Nd can be reported employing resin bead load techniques onto flat ribbon Re filaments or resin beads loaded into a millimeter-sized cavity drilled into a Re rod. This results in detection limits of <0.1 fg (10{sup 4} atoms to 10{sup 5} atoms) for {sup 239-242+244}Pu, {sup 233+236}U,more » {sup 241-243}Am, {sup 89,90}Sr, and {sup 134,135,137}Cs, and {le} 1 pg for natural Nd isotopes (limited by the chemical processing blank) using a secondary electron multiplier (SEM) or multiple-ion counters (MICs). Relative standard deviations (RSD) as small as 0.1% and abundance sensitivities of 1 x 10{sup 6} or better using a SEM are reported here. Precisions of RSD {approx} 0.01-0.001% using a multi-collector Faraday cup array can be achieved at sub-nanogram concentrations for strontium and neodymium and are suitable to gain crucial geolocation information. The analytical protocols reported herein are of particular value for nuclear forensic and nuclear safeguard applications.« less
Application of an ETV-ICP system for the determination of elements in human hair*1
NASA Astrophysics Data System (ADS)
Plantikow-Voβgätter, F.; Denkhaus, E.
1996-01-01
When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g -1), Mn (RSD < 14.1%, DL < 0.3 μ g -1), and Mg (RSD < 7.4%, DL < 6.6 μ g -1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.
Zhou, Joseph Ziqi; Waszkuc, Ted; Mohammed, Felicia
2008-01-01
A collaborative study was conducted for determination of glucosamine in raw materials and dietary supplements containing glucosamine sulfate and/or glucosamine hydrochloride by high-performance liquid Chromatography (HPLC) with N-(9-fluorenyl-methoxycarbonyloxy) succinimide (FMOC-Su) derivatization. Thirteen blind materials, one pair of which were duplicates, were tested by 12 collaborating laboratories. The test samples consisted of various commercial products, including tablets, capsules, drink mix, and liquids as well as raw materials, blanks, and those for spike recovery analyses. The tests with blank products and products spiked with glucosamine showed good specificity of the method. The average recoveries at spike levels of 100 and 150% of the declared amount were 99.0% with a relative standard deviation (RSD) of 2.1%, and 101% with an RSD of 2.3%, respectively. The test results between laboratories on each commercial product were reproducible with RSD values of no more than 4.0%, and the results were repeatable in the same laboratory with an average RSD of 0.7%. HorRat values ranged from 0.5 to 1.7 on both tests of spike recovery and reproducibility between laboratories on commercial products. The average determination coefficient of the calibration curves from the laboratories was 0.9995 with an RSD of 0.03%. All of the 12 collaborating laboratories succeeded in the study and none of their reported test results were outliers, partly indicating the robustness of the method. It is recommended that the method be accepted by AOAC INTERNATIONAL as Official First Action. PMID:16152919
A passive integrative sampler for mercury vapor in air and neutral mercury species in water
Brumbaugh, W.G.; Petty, J.D.; May, T.W.; Huckins, J.N.
2000-01-01
A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15 x 2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ??? 5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress. (C) 1999 Elsevier Science Ltd.A passive integrative mercury sampler (PIMS) based on a sealed polymeric membrane was effective for the collection and preconcentration of Hg0. Because the Hg is both oxidized and stabilized in the PIMS, sampling intervals of weeks to months are possible. The effective air sampling rate for a 15??2.5 cm device was about 21-equivalents/day (0.002 m3/day) and the detection limit for 4-week sampling was about 2 ng/m3 for conventional ICP-MS determination without clean-room preparation. Sampling precision was ???5% RSD for laboratory exposures, and 5-10% RSD for field exposures. These results suggest that the PIMS could be useful for screening assessments of Hg contamination and exposure in the environment, the laboratory, and the workplace. The PIMS approach may be particularly useful for applications requiring unattended sampling for extended periods at remote locations. Preliminary results indicate that sampling for dissolved gaseous mercury (DGM) and potentially other neutral mercury species from water is also feasible. Rigorous validation of the sampler performance is currently in progress.
A pretreatment method for HPLC analysis of cypermethrin in microbial degradation systems.
Liu, Shuliang; Yao, Kai; Jia, Dongying; Zhao, Nan; Lai, Wen; Yuan, Huaiyu
2012-07-01
In this paper, a pretreatment method for high-performance liquid chromatography (HPLC) determination of cypermethrin (CY) in microbial degradation systems was systemically studied, primarily to solve the problem of inaccurate determination of CY concentration caused by its uneven distribution in the systems. A suitable pretreatment method was established, including sampling, extraction and dehydration of CY. Partial sampling could be taken for bacterial and yeast systems in which CY was uniformly dispersed by an emulsifying agent, while total sampling was only suitable for mold systems with or without an emulsifying agent. CY could be fully extracted from the samples in which microbial cells were disrupted by ultrasonic treatment with acetonitrile under ultrasonic condition. The extract could be effectively dehydrated and purified by passing it through an anhydrous Na(2)SO(4) column followed by an elution with acetonitrile. The determination of CY in the pretreated sample by HPLC showed a high precision [relative standard deviation (RSD) = 1.14%, n = 5] and a good stability over a period of five days (RSD = 1.57%, n = 5). The recoveries of CY in microbial degradation systems at three different spiked levels ranged from 95.68 to 108.09% (RSD = 0.50-5.87%, n = 5).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bankston, D.C.; Humphris, S.E.; Thompson, G.
1979-07-01
A technique for the determination of major concentrations of SiO/sub 2/, Al/sub 2/O/sub 3/, Fe/sub 2/O/sub 3/, MgO, CaO, Na/sub 2/O, and K/sub 2/O, minor levels of TiO/sub 2/, P/sub 2/O/sub 5/, and MnO, and trace concentrations of Ba, Cr, Cu, Ni, Sr, V, and Zn, in semi-microsamples 200 mg) of powdered whole rock, is described. Chemically diverse standard reference rocks are used both for calibration and assessment of accuracy. A lithium metaborate fusion melt of each standard or sample is dissolved in dilute HNO/sub 3/ containing Cs/sup +/ at a level of 0.2% (w/v). The resulting solution is usedmore » to perform all analyses except those for Na/sub 2/O and K/sub 2/O, which are determined in a portion of the original sample solution wherein the Cs/sup +/ concentration has been raised to 0.32% (w/v). Analyses of both portions of each sample solution are performed using an optical emission spectrometer/spectrograph equipped with an echelle monochromator and a dc argon plasma excitation source. Trace element detection limits ranged from 2 ppM for Cu to 15 ppM for Zn. A study of precision based on replicate determinations in three splits of the proposed USGS reference basalt BHVO-1 yielded the following results: (1) For analyses of the major and minor oxide constituents, values of the percent relative standard deviation (RSD) ranged from 1 for CaO, to 21 for P/sub 2/O/sub 5/. 2) For trace element determinations, values of the RSD ranged from 2 for Cu, to 19 for Zn. 2 figures, 11 tables.« less
NASA Astrophysics Data System (ADS)
Yierpan, Aierken; König, Stephan; Labidi, Jabrane; Kurzawa, Timon; Babechuk, Michael G.; Schoenberg, Ronny
2018-02-01
The redox-sensitive, chalcophile, and volatile Se stable isotope system offers new perspectives to investigate the origin and evolution of terrestrial volatiles and the roles of magmatic and recycling processes in the development of the redox contrast between Earth's reservoirs. Selenium isotope systematics become more robust in a well-constrained petrogenetic context as can be inferred from Se-Te elemental signatures of sulfides and igneous rocks. In this study, we present a high-yield chemical sample processing method that allows the determination of Se-Te concentrations and Se isotope composition from the same sample digest of silicate rocks by hydride generation isotope dilution (ID) quadrupole inductively coupled plasma mass spectrometry (ICP-MS) and double spike (DS) multicollector (MC)-ICP-MS, respectively. Our procedure yields ˜80% Se-Te recoveries with quantitative separation of relevant interfering elements such as Ge and HG-buffering metals. Replicate analyses of selected international reference materials yield uncertainties better than 0.11‰ (2 s.d.) on δ82/76Se and 3% (r.s.d.) on Se concentration for DS MC-ICP-MS determinations for as low as ˜10 ng sample Se. The precision of Se-Te concentration measurements by ID ICP-MS is better than 3% and 5% (r.s.d.) for total amounts of ˜0.5-1 ng Se and ˜0.2-0.5 ng Te, respectively. The basaltic reference materials have variable Se-Te contents, but their δ82/76Se values are rather uniform (on average 0.23 ± 0.14‰; 2 s.d.) and different from the chondritic value. This altogether provides the methodology and potential to extend the limited data set of coupled Se isotope and Se-Te elemental systematics of samples relevant to study the terrestrial igneous inventory.
Shu, Xiaoyun; Tang, Yuping; Jiang, Chenxue; Shang, Erxing; Fan, Xinshen; Ding, Anwei
2012-11-01
A high performance liquid chromatographic (HPLC) method with diode array detection (DAD) was established for simultaneous determination of seven main bioactive components in San-ao decoction and its series of formulae (San-ao decoction, Wu-ao decoction, Qi-ao decoction and Jia-wei San-ao decoction). Seven compounds were analyzed simultaneously with a XTerra C(18) column (4.6 mm × 250 mm, 5 µm) using a linear gradient elution of a mobile phase containing acetonitrile (A) and a buffer solution (0.02 mol/L potassium dihydrogen phosphate and adjusted to pH 3 using phosphoric acid) (B); the flow rate was 1.0 mL/min. The sample was detected with DAD at 210, 254 and 360 nm and the column was maintained at 30 °C. All the compounds showed good linearity (r2 > 0.9984) in the tested concentration range. The precisions were evaluated by intra-day and inter-day tests, and relative standard deviation (R.S.D.) values within the range of 0.83%–2.53% and 0.64%–2.77% were reported, respectively. The recoveries of the quantified compounds were observed to cover a range from 95.34% and 104.82% with R.S.D. values less than 2.72%. The validated method was successfully applied for the simultaneous determination of seven main bioactive components including ephedrine (1), amygdalin (2), liquiritin (3), benzoic acid (4), isoliquiritin (5), formononetin (6) and glycyrrhizic acid (7) in San-ao decoction and its series of formulae. The results also showed a wide variation in the content of the identified active compounds in these samples, which could also be helpful to illustrate the drug interactions after some herbs combined in different formulations.
López, Laura B; Baroni, Andrea V; Rodríguez, Viviana G; Greco, Carola B; de Costa, Sara Macías; de Ferrer, Patricia Ronayne; Rodríguez de Pece, Silvia
2005-06-01
A methodology for the quantification of vitamin A in human milk was developed and validated. Vitamin A levels were assessed in 223 samples corresponding to the 5th, 6th and 7th postpartum months, obtained in the province of Santiago del Estero, Argentina. The samples (500 microL) were saponified with potassium hydroxide/ethanol, extracted with hexane, evaporated to dryness and reconstituted with methanol. A column RP-C18, a mobile phase methanol/water (91:9 v/v) and a fluorescence detector (lambda excitation 330 nm and lambda emition 470 nm) were used for the separation and quantification of vitamin A. The analytical parameters of linearity (r2: 0.9995), detection (0.010 microg/mL) and quantification (0.025 microg/mL) limits, precision of the method (relative standard deviation, RSD = 9.0% within a day and RSD = 8.9% among days) and accuracy (recovery = 83.8%) demonstrate that the developed method allows the quantification of vitamin A in an efficient way. The mean values + standard deviation (SD) obtained for the analyzed samples were 0.60 +/- 0.32; 0.65 +/- 0.33 and 0.61 +/- 0.26 microg/ mL for the 5th, 6th and 7th postpartum months, respectively. There were no significant differences among the three months studied and the values found were similar to those in the literature. Considering the whole population under study, 19.3% showed vitamin A levels less than 0.40 microg/mL, which represents a risk to the children in this group since at least 0.50 microg/mL are necessary to meet the infant daily needs.
2015-06-24
The method described below is intended for the quantification of all fatty acids, including commercially important groups of fatty acids used for labeling reasons (i.e., TFA, SFA, MUFA, PUFA, omega-3, omega-6, omega-9) and/or individual fatty acids (i.e., LA, ALA, ARA, EPA, DHA) in milk products, infant formula and adult/pediatric nutritional formula. These products often contain milk fat and/or vegetable oils, and are supplemented or not supplemented with oils rich in long chain polyunsaturated fatty acids (LC-PUFA). The determination is performed by direct transesterification of ready-to-feed liquid concentrate or powder products, without prior fat extraction. The single laboratory validation (SLV) data was submitted to the Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Expert Review Panel (ERP) for review at the AOAC INTERNATIONAL annual meeting held September 30 to October 3, 2012 in Las Vegas, Nevada. The ERP determined that the data reviewed met the Standard Method Performance Requirements (SMPR 2012.11) set by SPIFAN and was approved as an AOAC Official First Action. The analytical range for SPIFAN samples was between 0.001-7.94 g/100 g reconstituted product, or ready-to-feed liquid. The quantitation limit was estimated as 0.001 g/100 g, while repeatability and intermediate precision were both less than 1.8 % RSD above 0.05 g/100 g, and <3.5% RSD at 0.00 5g/100 g, respectively. Recovery values based on spiking experiments at two different levels of linoleic and linolenic acids ranged from 100.0% to 102.9% for 3 different SPIFAN products. All the parameters evaluated during the SLV were well within the values defined in SMPR 2012.011 (September 2012).
Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.
McClure, Foster D; Lee, Jung K
2006-01-01
A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.
Pugsley, Michael K; Goldin, Alan L
1999-01-01
RSD 921 is a novel, structurally unique, class I Na+ channel blocking drug under development as a local anaesthetic agent and possibly for the treatment of cardiac arrhythmias. The effects of RSD 921 on wild-type heart, skeletal muscle, neuronal and non-inactivating IFMQ3 mutant neuronal Na+ channels expressed in Xenopus laevis oocytes were examined using a two-electrode voltage clamp.RSD 921 produced similarly potent tonic block of all three wild-type channel isoforms, with EC50 values between 35 and 47 μM, whereas the EC50 for block of the IFMQ3 mutant channel was 110±5.5 μM.Block of Na+ channels by RSD 921 was concentration and use-dependent, with marked frequency-dependent block of heart channels and mild frequency-dependent block of skeletal muscle, wild-type neuronal and IFMQ3 mutant channels.RSD 921 produced a minimal hyperpolarizing shift in the steady-state voltage-dependence of inactivation of all three wild-type channel isoforms.Open channel block of the IFMQ3 mutant channel was best fit with a first order blocking scheme with kon equal to 0.11±0.012×106 M−1 s−1 and koff equal to 12.5±2.5 s−1, resulting in KD of 117±31 μM. Recovery from open channel block occurred with a time constant of 14±2.7 s−1.These results suggest that RSD 921 preferentially interacts with the open state of the Na+ channel, and that the drug may produce potent local anaesthetic or anti-arrhythmic action under conditions of shortened action potentials, such as during anoxia or ischaemia. PMID:10369450
Pugsley, M K; Goldin, A L
1999-05-01
RSD 921 is a novel, structurally unique, class I Na+ channel blocking drug under development as a local anaesthetic agent and possibly for the treatment of cardiac arrhythmias. The effects of RSD 921 on wild-type heart, skeletal muscle, neuronal and non-inactivating IFMQ3 mutant neuronal Na+ channels expressed in Xenopus laevis oocytes were examined using a two-electrode voltage clamp. RSD 921 produced similarly potent tonic block of all three wild-type channel isoforms, with EC50 values between 35 and 47 microM, whereas the EC50 for block of the IFMQ3 mutant channel was 110+5.5 microM. Block of Na+ channels by RSD 921 was concentration and use-dependent, with marked frequency-dependent block of heart channels and mild frequency-dependent block of skeletal muscle, wild-type neuronal and IFMQ3 mutant channels. RSD 921 produced a minimal hyperpolarizing shift in the steady-state voltage-dependence of inactivation of all three wild-type channel isoforms. Open channel block of the IFMQ3 mutant channel was best fit with a first order blocking scheme with k(on) equal to 0.11+/-0.012x10(6) M(-1) s(-1) and k(off) equal to 12.5+/-2.5 s(-1), resulting in KD of 117+/-31 microM. Recovery from open channel block occurred with a time constant of 14+/-2.7 s(-1). These results suggest that RSD 921 preferentially interacts with the open state of the Na+ channel, and that the drug may produce potent local anaesthetic or anti-arrhythmic action under conditions of shortened action potentials, such as during anoxia or ischaemia.
Fengler, Karl; Heinemann, Diana; Okon, Thomas; Röhnert, Karoline; Stiermaier, Thomas; von Röder, Maximilian; Besler, Christian; Müller, Ulrike; Höllriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp
2016-07-01
Despite the ongoing debate on the role of renal sympathetic denervation (RSD) in the management of therapy-resistant hypertension, little is known about its possible effects on exercise blood pressure (BP), a known predictor for future cardiovascular events. We sought to evaluate the effect of RSD on exercise BP in a randomized, sham-controlled trial in patients with mild hypertension. Patients with therapy-resistant mild hypertension (defined by mean daytime systolic BP between 135 and 149 mmHg or mean daytime diastolic BP between 90 and 94 mmHg on 24-h ambulatory BP measurement) were randomized to either radiofrequency-based RSD or a sham procedure. Patients underwent cardiopulmonary exercise testing at baseline and after 6 months. Of the 71 patients randomized, data from cardiopulmonary exercise testing were available for 48 patients (22 in the RSD group, 26 in the sham group). After 6 months, patients undergoing RSD had a significantly lower systolic BP at maximum exercise workload compared to baseline (-14.2 ± 26.1 mmHg, p = 0.009). In contrast, no change was observed in the sham group (0.6 ± 22.9 mmHg, p = 0.45, p = 0.04 for between-group comparison). When analyzing patients with exaggerated baseline exercise BP only, the effect was even more pronounced (RSD vs. sham -29.5 ± 23.4 vs. 0.1 ± 25.3 mmHg, p = 0.008). Exercise systolic BP values in patients with mild therapy-resistant hypertension are reduced after RSD as compared to a sham-procedure.
Zheng, Jian; Yamada, Masatoshi
2006-01-15
The determination of uranium is important for environmental radioactivity monitoring, which investigates the releases of uranium from nuclear facilities and of naturally occurring radioactive materials by the coal, oil, natural gas, mineral, ore refining and phosphate fertilizer industries, and it is also important for studies on the biogeochemical behavior of uranium in the environment. In this paper, we describe a quadrupole ICP-MS (ICP-QMS)-based analytical procedure for the accurate determination of U isotope ratios ((235)U/(238)U atom ratio and (234)U/(238)U activity ratio) in sediment samples. A two-stage sample cleanup using anion-exchange and TEVA extraction chromatography was employed in order to obtain accurate and precise (234)U/(238)U activity ratios. The factors that affect the accuracy and precision of U isotope ratio analysis, such as detector dead time, abundance sensitivity, dwell time and mass bias were carefully evaluated and corrected. With natural U, a precision lower than 0.5% R.S.D. for (235)U/(238)U atom ratio and lower than 2.0% R.S.D. for (234)U/(238)U activity ratio was obtained with less than 90 ng uranium. The developed analytical method was validated using an ocean sediment reference material and applied to an investigation into the uranium isotopic compositions in a sediment core in a brackish lake in the vicinity of U-related nuclear facilities in Japan.
Qualitative and quantitative measurement of cannabinoids in cannabis using modified HPLC/DAD method.
Patel, Bhupendra; Wene, Daniel; Fan, Zhihua Tina
2017-11-30
This study presents an accurate and high throughput method for the quantitative determination of various cannabinoids in cannabis plant material using high pressure liquid chromatography (HPLC) with a diode array detector (DAD). Sample extraction and chromatographic analysis conditions for the measurement of cannabinoids in the complex cannabis plant material matrix were optimized. The Agilent Poroshell 120 SB-C18 column provided high resolution for all target analytes with a short run time (10minutes) given the core shell technology. The aqueous buffer mobile phase was optimized with ammonium acetate at pH 4.75. The change in the mobile phase and the new column ensured a separation between cannabidiol (CBD and cannabigerol (CBG) along with cannabigerol and tetrahydrocannabinolic acid (THCA), which were not well separated by previous publications, improved buffering capacity, and provided analytical performance stability. Moreover, baseline drifting was significantly minimized by the use of a low concentration buffer solution (25mM ammonium acetate). In addition, evaporation and reconstitution of the sample residue with a methanol-organic pure (OP) water solution (65:35) significantly reduced the matrix interference. The modified extraction produced good recoveries (>91%) for each of the eight cannabinoids. The optimized method was validated for specificity, linearity, sensitivity, precision, accuracy, and stability. The combined relative standard deviation (%RSD) for intra-day and inter-day precision for all eight analytes varied from 2.5% to 5.2% and 0.28% to 5.5%, respectively. The %RSD for the repeatability study varied from 1.1% to 5.5%. The recoveries from spiked cannabis matrix samples were greater than 90% for all analytes, except delta-8-tetrahydrocannabinol (Δ 8 -THC), which was 80%. The recoveries varied from 81% to 107% with a precision of 0.7-8.1%RSD. Delta-9-tetrahydrocannabinol (Δ 9 -THC) in all of the cannabis samples (n=635) was less than 10%, which is in compliance with the NJ Medicinal Marijuana regulation. Analysis of samples from two cultivars, which included ten individual samples, four composite samples, seven calibration standards, and four quality control standards, can be performed within 24hours by this high throughput method. Published by Elsevier B.V.
Oiram Filho, Francisco; Alcântra, Daniel Barbosa; Rodrigues, Tigressa Helena Soares; Alexandre E Silva, Lorena Mara; de Oliveira Silva, Ebenezer; Zocolo, Guilherme Julião; de Brito, Edy Sousa
2018-04-01
Cashew nut shell liquid (CNSL) contains phenolic lipids with aliphatic chains that are of commercial interest. In this work, a chromatographic method was developed to monitor and quantify anacardic acids (AnAc) in CNSL. Samples containing AnAc were analyzed on a high-performance liquid chromatograph coupled to a diode array detector, equipped with a reversed phase C18 (150 × 4.6 mm × 5 μm) column using acetonitrile and water as the mobile phase both acidified with acetic acid to pH 3.0 in an isocratic mode (80:20:1). The chromatographic method showed adequate selectivity, as it could clearly separate the different AnAc. To validate this method, AnAc triene was used as an external standard at seven different concentrations varying from 50 to 1,000 μg mL-1. The Student's t-test and F-test were applied to ensure high confidence for the obtained data from the analytical calibration curve. The results were satisfactory with respect to intra-day (relative standard deviation (RSD) = 0.60%) and inter-day (RSD = 0.67%) precision, linearity (y = 2,670.8x - 26,949, r2 > 0.9998), system suitability for retention time (RSD = 1.02%), area under the curve (RSD = 0.24%), selectivity and limits of detection (19.8 μg mg-1) and quantification (60.2 μg mg-1). The developed chromatographic method was applied for the analysis of different CNSL samples, and it was deemed suitable for the quantification of AnAc.
NASA Astrophysics Data System (ADS)
Li, Xiongwei; Wang, Zhe; Lui, Siu-Lung; Fu, Yangting; Li, Zheng; Liu, Jianming; Ni, Weidou
2013-10-01
A bottleneck of the wide commercial application of laser-induced breakdown spectroscopy (LIBS) technology is its relatively high measurement uncertainty. A partial least squares (PLS) based normalization method was proposed to improve pulse-to-pulse measurement precision for LIBS based on our previous spectrum standardization method. The proposed model utilized multi-line spectral information of the measured element and characterized the signal fluctuations due to the variation of plasma characteristic parameters (plasma temperature, electron number density, and total number density) for signal uncertainty reduction. The model was validated by the application of copper concentration prediction in 29 brass alloy samples. The results demonstrated an improvement on both measurement precision and accuracy over the generally applied normalization as well as our previously proposed simplified spectrum standardization method. The average relative standard deviation (RSD), average of the standard error (error bar), the coefficient of determination (R2), the root-mean-square error of prediction (RMSEP), and average value of the maximum relative error (MRE) were 1.80%, 0.23%, 0.992, 1.30%, and 5.23%, respectively, while those for the generally applied spectral area normalization were 3.72%, 0.71%, 0.973, 1.98%, and 14.92%, respectively.
A preliminary study on identification of Thai rice samples by INAA and statistical analysis
NASA Astrophysics Data System (ADS)
Kongsri, S.; Kukusamude, C.
2017-09-01
This study aims to investigate the elemental compositions in 93 Thai rice samples using instrumental neutron activation analysis (INAA) and to identify rice according to their types and rice cultivars using statistical analysis. As, Mg, Cl, Al, Br, Mn, K, Rb and Zn in Thai jasmine rice and Sung Yod rice samples were successfully determined by INAA. The accuracy and precision of the INAA method were verified by SRM 1568a Rice Flour. All elements were found to be in a good agreement with the certified values. The precisions in term of %RSD were lower than 7%. The LODs were obtained in range of 0.01 to 29 mg kg-1. The concentration of 9 elements distributed in Thai rice samples was evaluated and used as chemical indicators to identify the type of rice samples. The result found that Mg, Cl, As, Br, Mn, K, Rb, and Zn concentrations in Thai jasmine rice samples are significantly different but there was no evidence that Al is significantly different from concentration in Sung Yod rice samples at 95% confidence interval. Our results may provide preliminary information for discrimination of rice samples and may be useful database of Thai rice.
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Díez, María Teresa; García del Moral, Pilar; Resines, José Antonio; Arín, María Jesús
2008-08-01
An RP-HPLC method for the determination of four phenolic compounds: gallic acid (GA), pyrogallol (PY), resorcinol (RE) and ellagic acid (EA), derived from hydrolysable tannins is reported. Separation was achieved on a SunFire C18 (250 x 4.6 mm id, 5 microm) column at 40 degrees C with gradient elution. UV detection at 280 nm was applied. The developed method was validated in terms of linearity, accuracy and precision. Satisfactory repeatability and between day precision were noticed with RSD values lower than 3%. Recoveries from different biological samples ranged from 91.50 to 105.25%. The LODs were estimated as 1.70 mg/L for PY, 1.68 mg/L for GA, 1.52 mg/L for RE and 0.98 mg/L for EA with a 20 microL injection volume. The method was applied for the determination of these compounds in oak leaves and in ruminal fluid and urine samples taken from beef cattle fed with oak leaves. The proposed method could be used in ruminant nutrition studies to verify the effect that a diet rich in tannins have on ruminal fermentation and to determine the toxicity of these compounds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gundlach-Graham, Alexander W.; Dennis, Elise; Ray, Steven J.
An inductively coupled plasma distance-of-flight mass spectrometer (ICP-DOFMS) has been coupled with laser-ablation (LA) sample introduction for the elemental analysis of solids. ICP-DOFMS is well suited for the analysis of laser-generated aerosols because it offers both high-speed mass analysis and simultaneous multi-elemental detection. Here, we evaluate the analytical performance of the LA-ICP-DOFMS instrument, equipped with a microchannel plate-based imaging detector, for the measurement of steady-state LA signals, as well as transient signals produced from single LA events. Steady-state detection limits are 1 mg g1, and absolute single-pulse LA detection limits are 200 fg for uranium; the system is shown capablemore » of performing time-resolved single-pulse LA analysis. By leveraging the benefits of simultaneous multi-elemental detection, we also attain a good shot-to-shot reproducibility of 6% relative standard deviation (RSD) and isotope-ratio precision of 0.3% RSD with a 10 s integration time.« less
Bianchi, F; Careri, M; Maffini, M; Mangia, A; Mucchino, C
2003-01-01
A sensitive method for the simultaneous determination of (7)Li, (27)Al and (56)Fe by cold plasma ICP-MS was developed and validated. Experimental design was used to investigate the effects of torch position, torch power, lens 2 voltage, and coolant flow. Regression models and desirability functions were applied to find the experimental conditions providing the highest global sensitivity in a multi-elemental analysis. Validation was performed in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LODs were 1.4 and 159 ng L(-1) for (7)Li and (56)Fe, respectively; the highest LOD found being that for (27)Al (425 ng L(-1)). Linear ranges of 5 orders of magnitude for Li and 3 orders for Fe were statistically verified for each compound. Precision was evaluated by testing two concentration levels, and good results in terms of both intra-day repeatability and intermediate precision were obtained. RSD values lower than 4.8% at the lowest concentration level were calculated for intra-day repeatability. Commercially available soft drinks and alcoholic beverages contained in different packaging materials (TetraPack, polyethylene terephthalate (PET), commercial cans and glass) were analysed, and all the analytes were detected and quantitated. Copyright 2002 John Wiley & Sons, Ltd.
Mahoney, P P; Ray, S J; Li, G; Hieftje, G M
1999-04-01
The coupling of an electrothermal vaporization (ETV) apparatus to an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) is described. The ability of the ICP-TOFMS to produce complete elemental mass spectra at high repetition rates is experimentally demonstrated. A signal-averaging data acquisition board is employed to rapidly record complete elemental spectra throughout the vaporization stage of the ETV temperature cycle; a solution containing 34 elements is analyzed. The reduction of both molecular and atomic isobaric interferences through the temperature program of the furnace is demonstrated. Isobaric overlaps among the isotopes of cadmium, tin, and indium are resolved by exploiting differences in the vaporization characteristics of the elements. Figures of merit for the system are defined with several different data acquisition schemes capable of operating at the high repetition rate of the TOF instrument. With the use of both ion counting and a boxcar averager, the dynamic range is shown to be linear over a range of at least 6 orders of magnitude. A pair of boxcar averagers are used to measure the isotope ratio for silver with a precision of 1.9% RSD, despite a cycle-to-cycle precision of 19% RSD. Detection limits of 10-80 fg are calculated for seven elements, based upon a 10-microL injection.
Serrano, Ana Belén; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo
2015-01-01
A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%–103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R2 of 0.991–0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L−1 and 40 ng·L−1 in plasma and between 5 ng·L−1 and 20 ng·L−1 in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors. PMID:26371043
Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh
2016-09-10
An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Salem, A. A.; Mossa, H. A.; Barsoum, B. N.
2005-11-01
Rapid, specific and simple methods for determining levofloxacin and rifampicin antibiotic drugs in pharmaceutical and human urine samples were developed. The methods are based on 1H NMR spectroscopy using maleic acid as an internal standard and DMSO-d6 as NMR solvent. Integration of NMR signals at 8.9 and 8.2 ppm were, respectively, used for calculating the concentration of levofloxacin and rifampicin drugs per unit dose. Maleic acid signal at 6.2 ppm was used as the reference signal. Recoveries of (97.0-99.4) ± 0.5 and (98.3-99.7) ± 1.08% were obtained for pure levofloxacin and rifampicin, respectively. Corresponding recoveries of 98.5-100.3 and 96.8-100.0 were, respectively, obtained in pharmaceutical capsules and urine samples. Relative standard deviations (R.S.D.) values ≤2.7 were obtained for analyzed drugs in pure, pharmaceutical and urine samples. Statistical Student's t-test gave t-values ≤2.87 indicating insignificant difference between the real and the experimental values at the 95% confidence level. F-test revealed insignificant difference in precisions between the developed NMR methods and each of fluorimetric and HPLC methods for analyzing levofloxacin and rifampicin.
Larcher, R; Nicolini, G; Bertoldi, D; Nardin, T
2008-02-25
A HPLC method using a coulometric electrode array detector (CEAD) to analyse 4-ethylcatechol in wine was established. The procedure does not require any sample preparation or analyte derivatisation and performs chromatographic separation in a short time. The assay method is linear up to 1520microgL(-1) and precise (R.S.D.<3%), with limits of detection and quantitation of 1.34microgL(-1) and 2.2microgL(-1), respectively. Recoveries in spiked wine samples ranged from 95% to 104% with a median value of 102% and matrix effects were not observed. The method was applied to the evaluation of the concentration of 4-EC in 250 commercial Italian wines. The red wines analysed had median, 75 degrees percentile and maximum values of 37microgL(-1), 89microgL(-1) and 1610microgL(-1), respectively. For Sangiovese-based wines the mean ratios of 4-EP and 4-EG to 4-EC were 3.7:1 and 0.7:1, respectively. The feasibility of a cheaper fluorimetric approach to 4-EC quantification was investigated.
Trace elements in a commercial freeze-dried human urine reference material.
Veillon, C; Patterson, K Y
1996-07-01
A large batch of freeze-dried human urine reference material, Seronorm Trace Elements Urine, Lot 101021, was prepared commercially (Nycomed Pharma AS, Oslo, Norway) for quality control purposes in trace element analysis. Analytes are being determined by a voluntary, international co-operative effort so that the material will be available to the scientific community at modest cost. The material is in stoppered glass vials and is to be reconstituted with 5.00 ml of water prior to use. We have evaluated the trace element content for several elements, including chromium and zinc, elements for which we have two independent methods available for the determinations, namely isotope dilution mass spectrometry (IDMS) and atomic absorption spectrometry (AAS). We also report on other trace elements measured by IDMS alone, such as Se, for which we have enriched stable isotopes available. Results for chromium indicate a mean +/- standard deviation (n = 10) of 1.2 +/- 0.3 (by IDMS) and 1.4 +/- 0.3 (by AAS) ng Cr per ml of reconstituted urine, indicating possible inhomogeneity and/or contamination (21-25% relative standard deviation, RSD). Approximately half of the observed chromium originates from the sample container. The values observed for zinc were 590 +/- 90 ng ml-1 (15% RSD) for freshly reconstituted material, 760 +/- 60 ng ml-1 (8% RSD) for material reconstituted 4 d earlier, and 940 +/- 60 ng ml-1 (6% RSD) 2 months after reconstitution. Selenium values by IDMS were very reproducible, with a mean concentration of 16 +/- 0.15 ng g-1 (0.9% RSD), suggesting little or no contamination and a high degree of sample homogeneity for this element. The source of potential contaminants has been evaluated by multielement determinations of leachates of the vials and stoppers. Elements noted in significant amounts include B, Ba, Sr, Mo, Cu and Zn, with most of the zinc coming from the rubber stopper.
Po, Sunny S.; Wang, Huan; Zhang, Ling; Zhang, Feng; Wang, Kun; Zhou, Qina
2013-01-01
Background Sympathetic activity involves the pathogenesis of atrial fibrillation (AF). Renal sympathetic denervation (RSD) decreases sympathetic renal afferent nerve activity, leading to decreased central sympathetic drive. The aim of this study was to identify the effects of RSD on AF inducibility induced by hyper-sympathetic activity in a canine model. Methods To establish a hyper-sympathetic tone canine model of AF, sixteen dogs were subjected to stimulation of left stellate ganglion (LSG) and rapid atrial pacing (RAP) for 3 hours. Then animals in the RSD group (n = 8) underwent radiofrequency ablation of the renal sympathetic nerve. The control group (n = 8) underwent the same procedure except for ablation. AF inducibility, effective refractory period (ERP), ERP dispersion, heart rate variability and plasma norepinephrine levels were measured at baseline, after stimulation and after ablation. Results LSG stimulation combined RAP significantly induced higher AF induction rate, shorter ERP, larger ERP dispersion at all sites examined and higher plasma norepinephrine levels (P<0.05 in all values), compared to baseline. The increased AF induction rate, shortened ERP, increased ERP dispersion and elevated plasma norepinephrine levels can be almost reversed by RSD, compared to the control group (P<0.05). LSG stimulation combined RAP markedly shortened RR-interval and standard deviation of all RR-intervals (SDNN), Low-frequency (LF), high-frequency (HF) and LF/HF ratio (P<0.05). These changes can be reversed by RSD, compared to the control group (P<0.05). Conclusions RSD significantly reduced AF inducibility and reversed the atrial electrophysiological changes induced by hyper-sympathetic activity. PMID:24223140
Gray, Dean; LeVanseler, Kerri; Pan, Meide
2008-01-01
A single laboratory validation (SLV) was completed for a method to determine the flavonol aglycones quercetin, kaempferol, and isorhamnetin in Ginkgo biloba products. The method calculates total glycosides based on these aglycones formed following acid hydrolysis. Nine matrixes were chosen for the study, including crude leaf material, standardized dry powder extract, single and multiple entity finished products, and ethanol and glycerol tinctures. For the 9 matrixes evaluated as part of this SLV, the method appeared to be selective and specific, with no observed interferences. The simplified 60 min oven heating hydrolysis procedure was effective for each of the matrixes studied, with no apparent or consistent differences between 60, 75, and 90 min at 90°C. A Youden ruggedness trial testing 7 factors with the potential to affect quantitative results showed that 2 factors (volume hydrolyzed and test sample extraction/hydrolysis weight) were the most important parameters for control during sample preparation. The method performed well in terms of precision, with 4 matrixes tested in triplicate over a 3-day period showing an overall repeatability (relative standard deviation, RSD) of 2.3%. Analysis of variance testing at α = 0.05 showed no significant differences among the within- or between-group sources of variation, although comparisons of within-day (Sw), between-day (Sb), and total (St) precision showed that a majority of the standard deviation came from within-day determinations for all matrixes. Accuracy testing at 2 levels (approximately 30 and 90% of the determined concentrations in standardized dry powder extract) from 2 complex negative control matrixes showed an overall 96% recovery and RSD of 1.0% for the high spike, and 94% recovery and RSD of 2.5% for the low spike. HorRat scores were within the limits for performance acceptability, ranging from 0.4 to 1.3. Based on the performance results presented herein, it is recommended that this method progress to the collaborative laboratory trial. PMID:16001841
Wiriyakun, Natta; Nacapricha, Duangjai; Chantiwas, Rattikan
2016-12-01
This work presents a simple hot embossing method with a shrinking procedure to produce cross-shape microchannels on poly(methyl methacrylate) (PMMA) substrate for the fabrication of an electrophoresis chip. The proposed method employed a simple two-step hot embossing technique, carried out consecutively on the same piece of substrate to make the crossing channels. Studies of embossing conditions, i.e. temperature, pressure and time, were carried out to investigate their effects on the dimension of the microchannels. Applying a simple shrinking procedure reduced the size of the channels from 700±20µm wide×150±5µm deep to 250±10µm wide×30±2µm deep, i.e. 80% and 64% reduction in the depth and width, respectively. Thermal fusion was employed to bond the PMMA substrate with a PMMA cover plate to produce the microfluidic device. Replication of microchip was achieved by precise control of conditions in the fabrication process (pressure, temperature and time), resulting in lower than 7% RSD of channel dimension, width and depth (n =10 devices). The method was simple and robust without the use of expensive equipment to construct the microstructure on a thermoplastic substrate. The PMMA microchip was used for demonstration of amine functionalization on the PMMA surface, measurement of electroosmotic flow and for electrophoretic separation of amino acids in functional drink samples. The precision of migration time and peak area of the amino acids, Lys, Ile and Phe at 125μM to 500μM, were in the range 3.2-4.2% RSD (n=9 devices) and 4.5-5.3% RSD (n=9 devices), respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Contrera, Joseph F
2011-02-01
The Threshold of Toxicological Concern (TTC) is a level of exposure to a genotoxic impurity that is considered to represent a negligible risk to humans. The TTC was derived from the results of rodent carcinogenicity TD50 values that are a measure of carcinogenic potency. The TTC currently sets a default limit of 1.5 μg/day in food contact substances and pharmaceuticals for all genotoxic impurities without carcinogenicity data. Bercu et al. (2010) used the QSAR predicted TD50 to calculate a risk specific dose (RSD) which is a carcinogenic potency adjusted TTC for genotoxic impurities. This promising approach is currently limited by the software used, a combination of MC4PC (www.multicase.com) and a Lilly Inc. in-house software (VISDOM) that is not available to the public. In this report the TD50 and RSD were predicted using a commercially available software, SciQSAR (formally MDL-QSAR, www.scimatics.com) employing the same TD50 training data set and external validation test set that was used by Bercu et al. (2010). The results demonstrate the general applicability of QSAR predicted TD50 values to determine the RSDs for genotoxic impurities and the improved performance of SciQSAR for predicting TD50 values. Copyright © 2010 Elsevier Inc. All rights reserved.
Wu, Chunwei; Guan, Qingxiao; Wang, Shumei; Rong, Yueying
2017-01-01
Root of Panax ginseng C. A. Mey (Renseng in Chinese) is a famous Traditional Chinese Medicine. Ginsenosides are the major bioactive components. However, the shortage and high cost of some ginsenoside reference standards make it is difficult for quality control of P. ginseng . A method, single standard for determination of multicomponents (SSDMC), was developed for the simultaneous determination of nine ginsenosides in P. ginseng (ginsenoside Rg 1 , Re, Rf, Rg 2 , Rb 1 , Rc, Rb 2 , Rb 3 , Rd). The analytes were separated on Inertsil ODS-3 C18 (250 mm × 4.6 mm, 5 μm) with gradient elution of acetonitrile and water. The flow rate was 1 mL/min and detection wavelength was set at 203 nm. The feasibility and accuracy of SSDMC were checked by the external standard method, and various high-performance liquid chromatographic (HPLC) instruments and chromatographic conditions were investigated to verify its applicability. Using ginsenoside Rg 1 as the internal reference substance, the contents of other eight ginsenosides were calculated according to conversion factors (F) by HPLC. The method was validated with linearity ( r 2 ≥ 0.9990), precision (relative standard deviation [RSD] ≤2.9%), accuracy (97.5%-100.8%, RSD ≤ 1.6%), repeatability, and stability. There was no significant difference between the SSDMC method and the external standard method. New SSDMC method could be considered as an ideal mean to analyze the components for which reference standards are not readily available. A method, single standard for determination of multicomponents (SSDMC), was established by high-performance liquid chromatography for the simultaneous determination of nine ginsenosides in Panax ginseng (ginsenoside Rg1, Re, Rf, Rg2, Rb1, Rc, Rb2, Rb3, Rd)Various chromatographic conditions were investigated to verify applicability of FsThe feasibility and accuracy of SSDMC were checked by the external standard method. Abbreviations used: DRT: Different value of retention time; F: Conversion factor; HPLC: High-performance Liquid Chromatography; LOD: Limit of detection; LOQ: Limit of quantitation; PD: Percent difference; PPD: 20(S)-protopanaxadiol; PPT: 20(S)-protopanaxatriol; RSD: Relative standard deviation; SSDMC: Single Standard for Determination of Multicomponents; TCM: Traditional Chinese Medicine.
Li, Tian-xue; Hu, Lang; Zhang, Meng-meng; Sun, Jian; Qiu, Yue; Rui, Jun-qian; Yang, Xing-hao
2014-01-01
There is a growing concern for the sensitive quantification of multiple components using advanced data acquisition method in herbal medicines (HMs). An improved and rugged UPLC-MS/MS method has been developed and validated for sensitive and rapid determination of multiply analytes from Tong-Xie-Yao-Fang (TXYF) decoction in three biological matrices (plasma/brain tissue/urine) using geniposide and formononetin as internal standards. After solid-phase extraction, chromatographic separation was performed on a C18 column using gradient elution. Quantifier and qualifier transitions were monitored using novel Triggered Dynamic multiple reaction monitoring (TdMRM) in the positive ionization mode. A significant peak symmetry and sensitivity improvement in the TdMRM mode was achieved as compared to conventional MRM. The reproducibility (RSD%) was ≤7.9% by applying TdMRM transition while the values were 6.8-20.6% for MRM. Excellent linear calibration curves were obtained under TdMRM transitions over the tested concentration ranges. Intra- and inter-day precisions (RSD%) were ≤14.2% and accuracies (RE%) ranged from -9.6% to 10.6%. The validation data of specificity, carryover, recovery, matrix effect and stability were within the required limits. The method was effectively applied to simultaneously detect and quantify 1 lactone, 2 monoterpene glucosides, 1 alkaloid, 5 flavonoids and 2 chromones in plasma, brain tissue and urine after oral administration of TXYF decoction. In conclusion, this new and reliable method is beneficial for quantification and confirmation assays of multiply components in complex biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.
2018-01-01
So-Cheong-Ryong-Tang, which is a standardized Korean medicine of the National Health Insurance, is a traditional prescription for the treatment of allergic rhinitis, bronchitis, and bronchial asthma. Simultaneous analysis and development of SCRT is essential for its stability, efficacy, and risk management. In this study, a simple, reliable, and accurate method using ultrahigh-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed for the simultaneous analysis. The chromatographic separation of the analytes was performed by an ACQUITY UPLC BEH C18 column (1.7 μM, 2.1 × 100 mm, Waters) with a mobile phase of water containing 0.01% (v/v) phosphoric acid and acetonitrile containing 0.01% (v/v) phosphoric acid. The flow rate and detection wavelength were set at 0.4 mL/min and 215, 230, 254, and 280 nm. All calibration curves of the thirteen components showed good linearity (R2 > 0.999). The limit of detection and limit of quantification ranged 0.001–0.360 and 0.004–1.200 µg/mL, respectively. The relative standard deviation (RSD) of intra- and interday was less than 2.60%, and the recoveries were within the range 76.08–103.79% with an RSD value of 0.03–1.50%. The results showed that the developed method was simple, reliable, accurate, sensitive, and precise for the quantification of bioactive components of SCRT. PMID:29854559
Van Dolah, Frances M; Leighfield, Tod A; Doucette, Gregory J; Bean, Laurie; Niedzwiadek, Barbara; Rawn, Dorothea F K
2009-01-01
A single-laboratory validation (SLV) study was conducted for the microplate receptor binding assay (RBA) for paralytic shellfish poisoning (PSP) toxins in shellfish. The basis of the assay is the competition between [3H]saxitoxin (STX) and STX in a standard or sample for binding to the voltage dependent sodium channel. A calibration curve is generated by the addition of 0.01-1000 nM STX, which results in the concentration dependent decrease in [3H]STX-receptor complexes formed and serves to quantify STX in unknown samples. This study established the LOQ, linearity, recovery, accuracy, and precision of the assay for determining PSP toxicity in shellfish extracts, as performed by a single analyst on multiple days. The standard curve obtained on 5 independent days resulted in a half-maximal inhibition (IC50) of 2.3 nM STX +/- 0.3 (RSD = 10.8%) with a slope of 0.96 +/- 0.06 (RSD = 6.3%) and a dynamic range of 1.2-10.0 nM. The LOQ was 5.3 microg STX equivalents/100 g shellfish. Linearity, established by quantification of three levels of purified STX (1.5, 3, and 6 nM), yielded an r2 of 0.97. Recovery from mussels spiked with three levels (40, 80, and 120 microg STX/100 g) averaged 121%. Repeatability (RSD(r)), determined on six naturally contaminated shellfish samples on 5 independent days, was 17.7%. A method comparison with the AOAC mouse bioassay yielded r2 = 0.98 (slope = 1.29) in the SLV study. The effects of the extraction method on RBA-based toxicity values were assessed on shellfish extracted for PSP toxins using the AOAC mouse bioassay method (0.1 M HCI) compared to that for the precolumn oxidation HPLC method (0.1% acetic acid). The two extraction methods showed linear correlation (r2 = 0.99), with the HCl extraction method yielding slightly higher toxicity values (slope = 1.23). A similar relationship was observed between HPLC quantification of the HCI- and acetic acid-extracted samples (r2 = 0.98, slope 1.19). The RBA also had excellent linear correlation with HPLC analyses (r2 = 0.98 for HCl, r2 = 0.99 for acetic acid), but gave somewhat higher values than HPLC using either extraction method (slope = 1.39 for HCl extracts, slope = 1.32 for acetic acid). Overall, the excellent linear correlations with the both mouse bioassay and HPLC method and sufficient interassay repeatability suggest that the RBA can be effective as a high throughput screen for estimating PSP toxicity in shellfish.
Menezes, Helvécio Costa; de Barcelos, Stella Maris Resende; Macedo, Damiana Freire Dias; Purceno, Aluir Dias; Machado, Bruno Fernades; Teixeira, Ana Paula Carvalho; Lago, Rochel Monteiro; Serp, Philippe; Cardeal, Zenilda Lourdes
2015-05-11
This paper describes a new, efficient and versatile method for the sampling and preconcentration of PAH in environmental water matrices using special hybrid magnetic carbon nanotubes. These N-doped amphiphilic CNT can be easily dispersed in any aqueous matrix due to the N containing hydrophilic part and at the same time show high efficiency for the adsorption of different PAH contaminants due to the very hydrophobic surface. After adsorption, the CNT can be easily removed from the medium by a simple magnetic separation. GC/MS analyses showed that the CNT method is more efficient than the use of polydimethylsiloxane (PDMS) with much lower solvent consumption, technical simplicity and time, showing good linearity (range 0.18-80.00 μg L(-1)) and determination coefficient (R(2) > 0.9810). The limit of detection ranged from 0.05 to 0.42 μg L(-1) with limit of quantification from 0.18 to 1.40 μg L(-1). Recovery (n=9) ranged from 80.50 ± 10 to 105.40 ± 12%. Intraday precision (RSD, n=9) ranged from 1.91 to 9.01%, whereas inter day precision (RSD, n=9) ranged from 7.02 to 17.94%. The method was applied to the analyses of PAH in four lake water samples collected in Belo Horizonte City, Brazil. Copyright © 2015 Elsevier B.V. All rights reserved.
Hansen, Sarah J Z; Morovic, Wesley; DeMeules, Martha; Stahl, Buffy; Sindelar, Connie W
2018-01-01
The current standard for enumeration of probiotics to obtain colony forming units by plate counts has several drawbacks: long time to results, high variability and the inability to discern between bacterial strains. Accurate probiotic cell counts are important to confirm the delivery of a clinically documented dose for its associated health benefits. A method is described using chip-based digital PCR (cdPCR) to enumerate Bifidobacterium animalis subsp. lactis Bl-04 and Lactobacillus acidophilus NCFM both as single strains and in combination. Primers and probes were designed to differentiate the target strains against other strains of the same species using known single copy, genetic differences. The assay was optimized to include propidium monoazide pre-treatment to prevent amplification of DNA associated with dead probiotic cells as well as liberation of DNA from cells with intact membranes using bead beating. The resulting assay was able to successfully enumerate each strain whether alone or in multiplex. The cdPCR method had a 4 and 5% relative standard deviation (RSD) for Bl-04 and NCFM, respectively, making it more precise than plate counts with an industry accepted RSD of 15%. cdPCR has the potential to replace traditional plate counts because of its precision, strain specificity and the ability to obtain results in a matter of hours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shekhar, R.; Karunasagar, D.; Ranjit, M.
An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstratedmore » good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Secchieri, M.; Benassi, C.A.; Pastore, S.
A method for the quail-quantitative evaluation of pentachlorophenol (PCP) in solid matrixes has been developed. The procedure is based on solid-liquid extraction of solid samples (leather or wood), followed by purification on a cyanopropyl column and determination of the preservative by second derivative UV spectroscopy considering the PCP A peak-through value (304-297 nm). The method allows rapid PCP determination in the concentration range 1-40 micrograms/mL; any matrix interference is avoided by the purification step and recoveries of the preservative were 99.12% (RSD% 0.13) for the leather matrix and 98.03 (RSD% 0.17) for the wood matrix.
NASA Astrophysics Data System (ADS)
Lo, Li; Shen, Chuan-Chou; Lu, Chia-Jung; Chen, Yi-Chi; Chang, Ching-Chih; Wei, Kuo-Yen; Qu, Dingchuang; Gagan, Michael K.
2014-02-01
We have developed a rapid and precise procedure for measuring multiple elements in foraminifera and corals by inductively coupled plasma sector field mass spectrometry (ICP-SF-MS) with both cold- [800 W radio frequency (RF) power] and hot- (1200 W RF power) plasma techniques. Our quality control program includes careful subsampling protocols, contamination-free workbench spaces, and refined plastic-ware cleaning process. Element/Ca ratios are calculated directly from ion beam intensities of 24Mg, 27Al, 43Ca, 55Mn, 57Fe, 86Sr, and 138Ba, using a standard bracketing method. A routine measurement time is 3-5 min per dissolved sample. The matrix effects of nitric acid, and Ca and Sr levels, are carefully quantified and overcome. There is no significant difference between data determined by cold- and hot-plasma methods, but the techniques have different advantages. The cold-plasma technique offers a more stable plasma condition and better reproducibility for ppm-level elements. Long-term 2-sigma relative standard deviations (2-RSD) for repeat measurements of an in-house coral standard are 0.32% for Mg/Ca and 0.43% for Sr/Ca by cold-plasma ICP-SF-MS, and 0.69% for Mg/Ca and 0.51% for Sr/Ca by hot-plasma ICP-SF-MS. The higher sensitivity and enhanced measurement precision of the hot-plasma procedure yields 2-RSD precision for μmol/mol trace elements of 0.60% (Mg/Ca), 9.9% (Al/Ca), 0.68% (Mn/Ca), 2.7% (Fe/Ca), 0.50% (Sr/Ca), and 0.84% (Ba/Ca) for an in-house foraminiferal standard. Our refined ICP-SF-MS technique, which has the advantages of small sample size (2-4 μg carbonate consumed) and fast sample throughput (5-8 samples/hour), should open the way to the production of high precision and high resolution geochemical records for natural carbonate materials.
Gravimetric method for the determination of diclofenac in pharmaceutical preparations.
Tubino, Matthieu; De Souza, Rafael L
2005-01-01
A gravimetric method for the determination of diclofenac in pharmaceutical preparations was developed. Diclofenac is precipitated from aqueous solution with copper(II) acetate in pH 5.3 (acetic acid/acetate buffer). Sample aliquots had approximately the same quantity of the drug content in tablets (50 mg) or in ampules (75 mg). The observed standard deviation was about +/- 2 mg; therefore, the relative standard deviation (RSD) was approximately 4% for tablet and 3% for ampule preparations. The results were compared with those obtained with the liquid chromatography method recommended in the United States Pharmacopoeia using the statistical Student's t-test. Complete agreement was observed. It is possible to obtain more precise results using higher aliquots, for example 200 mg, in which case the RSD falls to 1%. This gravimetric method, contrary to what is expected for this kind of procedure, is relatively fast and simple to perform. The main advantage is the absolute character of the gravimetric analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahyuni, Wulan Tri, E-mail: wulantriws@gmail.com; Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok; Ivandini, Tribidasari A.
Biomolecule modified magnetic beads has been widely used in separation and sensing process. This study used streptavidin modified magnetic beads to immobilize biotin modified zanamivir. Biotin-streptavidin affinity facilitates immobilization of zanamivir on magnetic beads. Then interaction of zanamivir and neuraminidase was adopted as basic for enzyme detection. Detection of neuraminidase was performed at gold modified BDD using cyclic voltammetry technique. The measurement was carried out based on alteration of electrochemical signals of working electrode as neuraminidase response. The result showed that zanamivir was successfully immobilized on magnetic beads. The optimum amount of magnetic beads for zanamivir immobilization was 120 ug.more » Linear responses of neuraminidase were detected in concentration range of 0-15 mU. Detection limit (LOD) of measurement was 2.32 mU (R2 = 0.959) with precision as % RSD of 1.41%. Measurement of neuraminidase on magnetic beads could be also performed in the presence of mucin matrix. The linearity range was 0-8 mU with LOD of 0.64 mU (R2 = 0.950) and % RSD of 7.25%.« less
Kathriarachchi, Udani L; Vidhate, Sagar S; Al-Tannak, Naser; Thomson, Alison H; da Silva Neto, Michael J J; Watson, David G
2018-07-01
A method was developed for the determination of amoxicillin and metronidazole in human serum. The procedure used was hydrophilic interaction chromatography (HILIC) followed by mass spectrometric (MS) detection. Chromatographic separation was achieved on a ZIC-HILIC column and the mobile phase consisted of a mixture of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile. The method was validated with regard to selectivity, accuracy, precision, calibration, lower limit of quantification (LOQ), extraction recovery and matrix effect. The LOQs were 0.0138 and 0.008 μg/ml for amoxicillin and metronidazole respectively, while for quantification purposes linearity was achieved in the range of 0.1 μg/ml to 6.4 μg/ml for both drugs with correlation coefficients >0.9990. The intraday precision (expressed as %RSD) and the accuracy (expressed as the % deviation from the nominal value) was <15% for both antibiotics at all QC levels. Extraction recoveries for both drugs and internal standards were >80%, while a considerable matrix effect (<60%) was observed for amoxicillin. Finally, the method was applied to the determination of amoxicillin and metronidazole concentrations in serum for 20 patients. Copyright © 2018 Elsevier B.V. All rights reserved.
Sadeghi, Fahimeh; Navidpour, Latifeh; Bayat, Sima; Afshar, Minoo
2013-01-01
A green, simple, and stability-indicating RP-HPLC method was developed for the determination of diltiazem in topical preparations. The separation was based on a C18 analytical column using a mobile phase consisted of ethanol: phosphoric acid solution (pH = 2.5) (35 : 65, v/v). Column temperature was set at 50°C and quantitation was achieved with UV detection at 240 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in diltiazem concentration range of 0.5–50 μg/mL (r 2 = 0.9996). Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.25%–101.66%) ensured the accuracy of the developed method. The degradation products as well as the pharmaceutical excipients were well resolved from the pure drug. The expanded uncertainty (5.63%) of the method was also estimated from method validation data. Accordingly, the proposed validated and sustainable procedure was proved to be suitable for routine analyzing and stability studies of diltiazem in pharmaceutical preparations. PMID:24163778
NASA Astrophysics Data System (ADS)
Fietzke, J.; Liebetrau, V.; Guenther, D.; Frische, M.; Zumholz, K.; Hansteen, T. H.; Eisenhauer, A.
2008-12-01
An alternative approach for the evaluation of isotope ratio data using LA-MC-ICP-MS will be presented. In contrast to previously applied methods it is based on the simultaneous responses of all analyte isotopes of interest and the relevant interferences without performing a conventional background correction. Significant improvements in precision and accuracy can be achieved when applying this new method and will be discussed based on the results of two first methodical applications: a) radiogenic and stable Sr isotopes in carbonates b) stable chlorine isotopes of pyrohydrolytic extracts. In carbonates an external reproducibility of the 87Sr/86Sr ratios of about 19 ppm (RSD) was achieved, an improvement of about a factor of 5. For recent and sub-recent marine carbonates a mean radiogenic strontium isotope ratio 87Sr/86Sr of 0.709170±0.000007 (2SE) was determined, which agrees well with the value of 0.7091741±0.0000024 (2SE) reported for modern sea water [1,2]. Stable chlorine isotope ratios were determined ablating pyrohydrolytic extracts with a reproducibility of about 0.05‰ (RSD). For basaltic reference material JB1a and JB2 chlorine isotope ratios were determined relative to SMOC (standard mean ocean chlorinity) δ37ClJB-1a = (-0.99±0.06) ‰ and δ37ClJB-1a = (-0.60±0.03) ‰ (SD), respectively, in accordance with published data [3]. The described strategies for data reduction are considered to be generally applicable for all isotope ratio measurements using LA-MC-ICP-MS. [1] J.M. McArthur, D. Rio, F. Massari, D. Castradori, T.R. Bailey, M. Thirlwall, S. Houghton, Palaeogeo. Palaeoclim. Palaeoeco., 2006, 242 (126), doi: 10.1016/j.palaeo.2006.06.004 [2] J. Fietzke, V. Liebetrau, D. Guenther, K. Guers, K. Hametner, K. Zumholz, T.H. Hansteen and A. Eisenhauer, J. Anal. At. Spectrom., 2008, 23, 955-961, doi:10.1039/B717706B [3] J. Fietzke, M. Frische, T.H. Hansteen and A. Eisenhauer, J. Anal. At. Spectrom., 2008, 23, 769-772, doi:10.1039/B718597A
Flores, Bruno C; White, Jonathan A; Batjer, H Hunt; Samson, Duke S
2018-05-04
OBJECTIVE Paraclinoid internal carotid artery (ICA) aneurysms frequently require temporary occlusion to facilitate safe clipping. Brisk retrograde flow through the ophthalmic artery and cavernous ICA branches make simple trapping inadequate to soften the aneurysm. The retrograde suction decompression (RSD), or Dallas RSD, technique was described in 1990 in an attempt to overcome some of those treatment limitations. A frequent criticism of the RSD technique is an allegedly high risk of cervical ICA dissection. An endovascular modification was introduced in 1991 (endovascular RSD) but no studies have compared the 2 RSD variations. METHODS The authors performed a systematic review of MEDLINE/PubMed and Web of Science and identified all studies from 1990-2016 in which either Dallas RSD or endovascular RSD was used for treatment of paraclinoid aneurysms. A pooled analysis of the data was completed to identify important demographic and treatment-specific variables. The primary outcome measure was defined as successful aneurysm obliteration. Secondary outcome variables were divided into overall and RSD-specific morbidity and mortality rates. RESULTS Twenty-six RSD studies met the inclusion criteria (525 patients, 78.9% female). The mean patient age was 53.5 years. Most aneurysms were unruptured (56.6%) and giant (49%). The most common presentations were subarachnoid hemorrhage (43.6%) and vision changes (25.3%). The aneurysm obliteration rate was 95%. The mean temporary occlusion time was 12.7 minutes. Transient or permanent morbidity was seen in 19.9% of the patients. The RSD-specific complication rate was low (1.3%). The overall mortality rate was 4.2%, with 2 deaths (0.4%) attributable to the RSD technique itself. Good or fair outcome were reported in 90.7% of the patients. Aneurysm obliteration rates were similar in the 2 subgroups (Dallas RSD 94.3%, endovascular RSD 96.3%, p = 0.33). Despite a higher frequency of complex (giant or ruptured) aneurysms, Dallas RSD was associated with lower RSD-related morbidity (0.6% vs 2.9%, p = 0.03), compared with the endovascular RSD subgroup. There was a trend toward higher mortality in the endovascular RSD subgroup (6.4% vs 3.1%, p = 0.08). The proportion of patients with poor neurological outcome at last follow-up was significantly higher in the endovascular RSD group (15.4% vs 7.2%, p < 0.01). CONCLUSIONS The treatment of paraclinoid ICA aneurysms using the RSD technique is associated with high aneurysm obliteration rates, good long-term neurological outcome, and low RSD-related morbidity and mortality. Review of the RSD literature showed no evidence of a higher complication rate associated with the Dallas technique compared with similar endovascular methods. On a subgroup analysis of Dallas RSD and endovascular RSD, both groups achieved similar obliteration rates, but a lower RSD-related morbidity was seen in the Dallas technique subgroup. Twenty-five years after its initial publication, RSD remains a useful neurosurgical technique for the management of large and giant paraclinoid aneurysms.
Pizzutti, Ionara R; Vreuls, René J J; de Kok, André; Roehrs, Rafael; Martel, Samile; Friggi, Caroline A; Zanella, Renato
2009-04-10
In this study, a new modulator that is simple, robust and presents low operation costs, was developed. This modulator uses compressed air to cool two small portions in the first centimeters of the second chromatographic column of a comprehensive multidimensional gas chromatography (GCxGC) system. The results show a variation in the peak area less than 3 and 5% to alkanes and pesticides, respectively. The standard deviations for the retention times in the first and second dimension are around 0.05 min and 0.05s for all the compounds. The system was optimized with n-alkanes. The GCxGC system proposed was applied in the determination of pyrethroid pesticides (bifenthrin, cypermethrin, deltamethrin, fenvalerate, esfenvalerate, cis- and trans-permethrin) in grape samples. Samples were extracted by the mini-Luke modified method and pesticides were quantified by comprehensive multidimensional gas chromatography with micro electron-capture detection (microECD). The values of method limit of quantification (LOQ) were 0.01-0.02 mg kg(-1) for all studied pyrethroid and the values of recovery were between 94.3 and 115.2%, with good precision (RSD<18.4%), demonstrating that the performance of the total method consisting of a modified Luke extraction method and determination by GCxGC-microECD are satisfactory. This study also showed that the system using a modulator with a double jet of compressed air has the potential for application in the analysis of a wider range of pesticide residues in other commodities since it provides low values of LOQ with acceptable accuracy and precision.
Batrawi, Nidal; Wahdan, Shorouq; Abualhasan, Murad
2017-01-01
Medroxyprogesterone acetate is widely used in veterinary medicine as intravaginal dosage for the synchronization of breeding cycle in ewes and goats. The main goal of this study was to develop reverse-phase high-performance liquid chromatography method for the quantification of medroxyprogesterone acetate in veterinary vaginal sponges. A single high-performance liquid chromatography/UV isocratic run was used for the analytical assay of the active ingredient medroxyprogesterone. The chromatographic system consisted of a reverse-phase C18 column as the stationary phase and a mixture of 60% acetonitrile and 40% potassium dihydrogen phosphate buffer as the mobile phase; the pH was adjusted to 5.6. The method was validated according to the International Council for Harmonisation (ICH) guidelines. Forced degradation studies were also performed to evaluate the stability-indicating properties and specificity of the method. Medroxyprogesterone was eluted at 5.9 minutes. The linearity of the method was confirmed in the range of 0.0576 to 0.1134 mg/mL (R2 > 0.999). The limit of quantification was shown to be 3.9 µg/mL. Precision and accuracy ranges were found to be %RSD <0.2 and 98% to 102%, respectively. Medroxyprogesterone capacity factor value of 2.1, tailing factor value of 1.03, and resolution value of 3.9 were obtained in accordance with ICH guidelines. Based on the obtained results, a rapid, precise, accurate, sensitive, and cost-effective analysis procedure was proposed for quantitative determination of medroxyprogesterone in vaginal sponges. This analytical method is the only available method to analyse medroxyprogesterone in veterinary intravaginal dosage form. PMID:28469407
Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp
2016-06-12
Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (p<0.01 with repeated measures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.
Han, Wang; Sundaram, Prema; Kenjale, Himanshu; Grantham, James; Timmons, Lisa
2008-04-01
In Caenorhabditis elegans, exogenous dsRNA can elicit systemic RNAi, a process that requires the function of many genes. Considering that the activities of many of these genes are also required for normal development, it is surprising that exposure to high concentrations of dsRNA does not elicit adverse consequences to animals. Here, we report inducible phenotypes in attenuated C. elegans strains reared in environments that include nonspecific dsRNA and elevated temperature. Under these conditions, chromosome integrity is compromised in RNAi-defective strains harboring mutations in rsd-2 or rsd-6. Specifically, rsd-2 mutants display defects in transposon silencing, while meiotic chromosome disjunction is affected in rsd-6 mutants. RSD-2 proteins localize to multiple cellular compartments, including the nucleolus and cytoplasmic compartments that, in part, are congruent with calreticulin and HAF-6. We considered that the RNAi defects in rsd-2 mutants might have relevance to membrane-associated functions; however, endomembrane compartmentalization and endocytosis/exocytosis markers in rsd-2 and rsd-6 mutants appear normal. The mutants also possess environmentally sensitive defects in cell-autonomous RNAi elicited from transgene-delivered dsRNAs. Thus, the ultimate functions of rsd-2 and rsd-6 in systemic RNAi are remarkably complex and environmentally responsive.
Determination of patulin in commercial apple juice by micellar electrokinetic chromatography.
Murillo, M; González-Peñas, E; Amézqueta, S
2008-01-01
A novel and validated micellar electrokinetic capillary chromatography (MEKC) method using ultraviolet detection (UV) has been applied to the quantitative analysis of patulin (PAT) in commercial apple juice. Patulin was extracted from samples with an ethylacetate solution. The micellar electrokinetic capillary chromatography (MECK) parameters studied for method optimization were buffer composition, voltage, temperature, and a separation between PAT and 5-hydroxymethylfurfural (HMF) (main interference in apple juice PAT analysis) peaks until reaching baseline. The method passes a series of validation tests including selectivity, linearity, limit of detection and quantification (0.7 and 2.5 microgL(-1), respectively), precision (within and between-day variability) and recovery (80.2% RSD=4%), accuracy, and robustness. This method was successfully applied to the measurement of 20 apple juice samples obtained from different supermarkets. One hundred percent of the samples were contaminated with a level greater than the limit of detection, with mean and median values of 41.3 and 35.7 microgL(-1), respectively.
NASA Astrophysics Data System (ADS)
Abdel Ghany, Maha F.; Hussein, Lobna A.; Magdy, Nancy; Yamani, Hend Z.
2016-03-01
Three spectrophotometric methods have been developed and validated for determination of indacaterol (IND) and glycopyrronium (GLY) in their binary mixtures and novel pharmaceutical dosage form. The proposed methods are considered to be the first methods to determine the investigated drugs simultaneously. The developed methods are based on different signal processing techniques of ratio spectra namely; Numerical Differentiation (ND), Savitsky-Golay (SG) and Fourier Transform (FT). The developed methods showed linearity over concentration range 1-30 and 10-35 (μg/mL) for IND and GLY, respectively. The accuracy calculated as percentage recoveries were in the range of 99.00%-100.49% with low value of RSD% (< 1.5%) demonstrating an excellent accuracy of the proposed methods. The developed methods were proved to be specific, sensitive and precise for quality control of the investigated drugs in their pharmaceutical dosage form without the need for any separation process.
Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad
2016-01-01
The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3) for chloramphenicol (12.5 µg/Kg) and florfenicol (12.2 µg/Kg), and precision with relative standard deviation values under 15% (RSD, n = 3). Good recoveries (69.1-79.4%) were obtained for the extraction of the target analytes in milk samples. This simple and economic method has been applied for analyses of 15 real milk samples. Among all samples only one of them was contaminated to florfenicol; 62.4 µg/Kg and contamination to chloramphenicol was not detected.
Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad
2016-01-01
The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3) for chloramphenicol (12.5 µg/Kg) and florfenicol (12.2 µg/Kg), and precision with relative standard deviation values under 15% (RSD, n = 3). Good recoveries (69.1–79.4%) were obtained for the extraction of the target analytes in milk samples. This simple and economic method has been applied for analyses of 15 real milk samples. Among all samples only one of them was contaminated to florfenicol; 62.4 µg/Kg and contamination to chloramphenicol was not detected. PMID:27980571
Shimamura, Tomoko; Sumikura, Yoshihiro; Yamazaki, Takeshi; Tada, Atsuko; Kashiwagi, Takehiro; Ishikawa, Hiroya; Matsui, Toshiro; Sugimoto, Naoki; Akiyama, Hiroshi; Ukeda, Hiroyuki
2014-01-01
An inter-laboratory evaluation study was conducted in order to evaluate the antioxidant capacity of food additives by using a 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Four antioxidants used as existing food additives (i.e., tea extract, grape seed extract, enju extract, and d-α-tocopherol) and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) were used as analytical samples, and 14 laboratories participated in this study. The repeatability relative standard deviation (RSD(r)) of the IC50 of Trolox, four antioxidants, and the Trolox equivalent antioxidant capacity (TEAC) were 1.8-2.2%, 2.2-2.9%, and 2.1-2.5%, respectively. Thus, the proposed DPPH assay showed good performance within the same laboratory. The reproducibility relative standard deviation (RSD(R)) of IC50 of Trolox, four antioxidants, and TEAC were 4.0-7.9%, 6.0-11%, and 3.7-9.3%, respectively. The RSD(R)/RSD(r) values of TEAC were lower than, or nearly equal to, those of IC50 of the four antioxidants, suggesting that the use of TEAC was effective for reducing the variance among the laboratories. These results showed that the proposed DPPH assay could be used as a standard method to evaluate the antioxidant capacity of food additives.
Patikoglou, Georgia A; Westblade, Lars F; Campbell, Elizabeth A; Lamour, Valérie; Lane, William J; Darst, Seth A
2007-09-21
The Escherichia coli Rsd protein binds tightly and specifically to the RNA polymerase (RNAP) sigma(70) factor. Rsd plays a role in alternative sigma factor-dependent transcription by biasing the competition between sigma(70) and alternative sigma factors for the available core RNAP. Here, we determined the 2.6 A-resolution X-ray crystal structure of Rsd bound to sigma(70) domain 4 (sigma(70)(4)), the primary determinant for Rsd binding within sigma(70). The structure reveals that Rsd binding interferes with the two primary functions of sigma(70)(4), core RNAP binding and promoter -35 element binding. Interestingly, the most highly conserved Rsd residues form a network of interactions through the middle of the Rsd structure that connect the sigma(70)(4)-binding surface with three cavities exposed on distant surfaces of Rsd, suggesting functional coupling between sigma(70)(4) binding and other binding surfaces of Rsd, either for other proteins or for as yet unknown small molecule effectors. These results provide a structural basis for understanding the role of Rsd, as well as its ortholog, AlgQ, a positive regulator of Pseudomonas aeruginosa virulence, in transcription regulation.
Crystal structure of the Escherichia coli regulator of σ70, Rsd, in complex with σ70 domain 4
Patikoglou, Georgia A.; Westblade, Lars F.; Campbell, Elizabeth A.; Lamour, Valérie; Lane, William J.; Darst, Seth A.
2007-01-01
Summary The Escherichia coli Rsd protein binds tightly and specifically to the RNA polymerase (RNAP) σ70 factor. Rsd plays a role in alternative σ factor-dependent transcription by biasing the competition between σ70 and alternative σ factors for the available core RNAP. Here, we determined the 2.6 Å-resolution X-ray crystal structure of Rsd bound to σ70 domain 4 (σ704), the primary determinant for Rsd binding within σ70. The structure reveals that Rsd binding interferes with the two primary functions of σ704, core RNAP binding and promoter –35 element binding. Interestingly, the most highly conserved Rsd residues form a network of interactions through the middle of the Rsd structure that connect the σ704-binding surface with three cavities exposed on distant surfaces of Rsd, suggesting functional coupling between σ704 binding and other binding surfaces of Rsd, either for other proteins or for as yet unknown small molecule effectors. These results provide a structural basis for understanding the role of Rsd, as well as its ortholog, AlgQ, a positive regulator of Pseudomonas aeruginosa virulence, in transcription regulation. PMID:17681541
[Cloning and characterization of a novel rat gene RSD-7 differentially expressed in testis].
Zhang, Xiao-dong; Gou, Da-wei; Miao, Shi-ying; Zhang, Jian-chao; Zong, Shu-dong; Wang, Lin-fang
2003-06-01
To isolate and identify the differentially expressed genes in spermatogenesis for the understanding molecular mechanism of spermatogenesis. Screening of the cDNA library, Northern blot, expression and purification in E. coli with GST expression system, immunocytochemical staining of testis sections were used. (1) A cDNA fragment designated as RSD-7 was isolated from rat testis cDNA library. It was 1,238 bp in length, coding a protein of 232 amino acids with the GenBank accession number AF315467. The encoding protein of RSD-7 cDNA had a Ubiquitin-like domain. (2) Northern blot indicated that RSD-7 was uniquely expressed in rat testis, and in the testis RSD-7 emerged on the 30th postnatal day and expressed until 120th postnatal day. (3) Expression and purification of RSD-7 protein in E. coli with GST expression system and were used to obtain anti-RSD-7 antibody. (4) Immunolocalization of RSD-7 in rat testis revealed that it is expressed only in Sertoli cells. Transcription pattern of RSD-7 and localization of RSD-7 protein in testis have been made, which established the base for the functional study of RSD-7.
Sakaguchi, Aisa; Sarkies, Peter; Simon, Matt; Doebley, Anna-Lisa; Goldstein, Leonard D; Hedges, Ashley; Ikegami, Kohta; Alvares, Stacy M; Yang, Liwei; LaRocque, Jeannine R; Hall, Julie; Miska, Eric A; Ahmed, Shawn
2014-10-14
Germ cells are maintained in a pristine non-aging state as they proliferate over generations. Here, we show that a novel function of the Caenorhabditis elegans RNA interference proteins RNAi spreading defective (RSD)-2 and RSD-6 is to promote germ cell immortality at high temperature. rsd mutants cultured at high temperatures became progressively sterile and displayed loss of small interfering RNAs (siRNAs) that target spermatogenesis genes, simple repeats, and transposons. Desilencing of spermatogenesis genes occurred in late-generation rsd mutants, although defective spermatogenesis was insufficient to explain the majority of sterility. Increased expression of repetitive loci occurred in both germ and somatic cells of late-generation rsd mutant adults, suggesting that desilencing of many heterochromatic segments of the genome contributes to sterility. Nuclear RNAi defective (NRDE)-2 promotes nuclear silencing in response to exogenous double-stranded RNA, and our data imply that RSD-2, RSD-6, and NRDE-2 function in a common transgenerational nuclear silencing pathway that responds to endogenous siRNAs. We propose that RSD-2 and RSD-6 promote germ cell immortality at stressful temperatures by maintaining transgenerational epigenetic inheritance of endogenous siRNA populations that promote genome silencing.
Sakaguchi, Aisa; Sarkies, Peter; Simon, Matt; Doebley, Anna-Lisa; Goldstein, Leonard D.; Hedges, Ashley; Ikegami, Kohta; Alvares, Stacy M.; Yang, Liwei; LaRocque, Jeannine R.; Hall, Julie; Miska, Eric A.; Ahmed, Shawn
2014-01-01
Germ cells are maintained in a pristine non-aging state as they proliferate over generations. Here, we show that a novel function of the Caenorhabditis elegans RNA interference proteins RNAi spreading defective (RSD)-2 and RSD-6 is to promote germ cell immortality at high temperature. rsd mutants cultured at high temperatures became progressively sterile and displayed loss of small interfering RNAs (siRNAs) that target spermatogenesis genes, simple repeats, and transposons. Desilencing of spermatogenesis genes occurred in late-generation rsd mutants, although defective spermatogenesis was insufficient to explain the majority of sterility. Increased expression of repetitive loci occurred in both germ and somatic cells of late-generation rsd mutant adults, suggesting that desilencing of many heterochromatic segments of the genome contributes to sterility. Nuclear RNAi defective (NRDE)-2 promotes nuclear silencing in response to exogenous double-stranded RNA, and our data imply that RSD-2, RSD-6, and NRDE-2 function in a common transgenerational nuclear silencing pathway that responds to endogenous siRNAs. We propose that RSD-2 and RSD-6 promote germ cell immortality at stressful temperatures by maintaining transgenerational epigenetic inheritance of endogenous siRNA populations that promote genome silencing. PMID:25258416
Comparative study of different alcohol sensors based on Screen-Printed Carbon Electrodes.
Costa Rama, Estefanía; Biscay, Julien; González García, María Begoña; Julio Reviejo, A; Pingarrón Carrazón, José Manuel; Costa García, Agustín
2012-05-30
Different very simple single-use alcohol enzyme sensors were developed using alcohol oxidase (AOX) from three different yeast, Hansenula sp., Pichia pastoris and Candida boidinii, and employing three different commercial mediator-based Screen-Printed Carbon Electrodes as transducers. The mediators tested, Prussian Blue, Ferrocyanide and Co-phthalocyanine were included into the ink of the working electrode. The procedure to obtain these sensors consists of the immobilization of the enzyme on the electrode surface by adsorption. For the immobilization, an AOX solution is deposited on the working electrode and left until dried (1h) at room temperature. The best results were obtained with the biosensor using Screen-Printed Co-phthalocyanine/Carbon Electrode and AOX from Hansenula sp. The reduced cobalt-phthalocyanine form is amperometrically detected at +0.4V (vs. Ag pseudo reference electrode). This sensor shows good sensitivity (1211 nA mM(-1)), high precision (2.1% RSD value for the slope value of the calibration plot) and wide linear response (0.05-1.00 mM) for ethanol determination. The sensor provides also accurate results for ethanol quantification in alcoholic drinks. Copyright © 2012 Elsevier B.V. All rights reserved.
Naccarato, Attilio; Gionfriddo, Emanuela; Elliani, Rosangela; Sindona, Giovanni; Tagarelli, Antonio
2014-10-30
The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5, 30 and 80mgl -1 , provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5mgl -1 ). The LOD values achieved by the proposed method ranged between 1.0 and 473μgl -1 . Copyright © 2014 Elsevier B.V. All rights reserved.
Lopez-Gazpio, Josu; Garcia-Arrona, Rosa; Millán, Esmeralda
2015-04-01
In this work, a simple and reliable micellar electrokinetic chromatography method for the separation and quantification of 14 preservatives, including isothiazolinones, and two benzophenone-type UV filters in household, cosmetic and personal care products was developed. The selected priority compounds are widely used as ingredients in many personal care products, and are included in the European Regulation concerning cosmetic products. The electrophoretic separation parameters were optimized by means of a modified chromatographic response function in combination with an experimental design, namely a central composite design. After optimization of experimental conditions, the BGE selected for the separation of the targets consisted of 60 mM SDS, 18 mM sodium tetraborate, pH 9.4 and 10% v/v methanol. The MEKC method was checked in terms of linearity, LODs and quantification, repeatability, intermediate precision, and accuracy, providing appropriate values (i.e. R(2) ≥ 0.992, repeatability RSD values ˂9%, and accuracy 90-115%). Applicability of the validated method was successfully assessed by quantifying preservatives and UV filters in commercial consumer products. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gundlach-Graham, Alexander W.; Dennis, Elise; Ray, Steven J.
Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, wemore » have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.« less
Hollands, Wendy J; Voorspoels, Stefan; Jacobs, Griet; Aaby, Kjersti; Meisland, Ane; Garcia-Villalba, Rocio; Tomas-Barberan, Francisco; Piskula, Mariusz K; Mawson, Deborah; Vovk, Irena; Needs, Paul W; Kroon, Paul A
2017-04-28
There is a lack of data for individual oligomeric procyanidins in apples and apple extracts. Our aim was to develop, validate and evaluate an analytical method for the separation, identification and quantification of monomeric and oligomeric flavanols in apple extracts. To achieve this, we prepared two types of flavanol extracts from freeze-dried apples; one was an epicatechin-rich extract containing ∼30% (w/w) monomeric (-)-epicatechin which also contained oligomeric procyanidins (Extract A), the second was an oligomeric procyanidin-rich extract depleted of epicatechin (Extract B). The parameters considered for method optimisation were HPLC columns and conditions, sample heating, mass of extract and dilution volumes. The performance characteristics considered for method validation included standard linearity, method sensitivity, precision and trueness. Eight laboratories participated in the method evaluation. Chromatographic separation of the analytes was best achieved utilizing a Hilic column with a binary mobile phase consisting of acidic acetonitrile and acidic aqueous methanol. The final method showed linearity for epicatechin in the range 5-100μg/mL with a correlation co-efficient >0.999. Intra-day and inter-day precision of the analytes ranged from 2 to 6% and 2 to 13% respectively. Up to dp3, trueness of the method was >95% but decreased with increasing dp. Within laboratory precision showed RSD values <5 and 10% for monomers and oligomers, respectively. Between laboratory precision was 4 and 15% (Extract A) and 7 and 30% (Extract B) for monomers and oligomers, respectively. An analytical method for the separation, identification and quantification of procyanidins in an apple extract was developed, validated and assessed. The results of the inter-laboratory evaluation indicate that the method is reliable and reproducible. Copyright © 2017. Published by Elsevier B.V.
Sardella, Roccaldo; Gioiello, Antimo; Ianni, Federica; Venturoni, Francesco; Natalini, Benedetto
2012-10-15
The employment of the flow N-acyl amidation of natural bile acids (BAs) required the in-line connection with suitable analytical tools enabling the determination of reaction yields as well as of the purity grade of the synthesized glyco- and tauro-conjugated derivatives. In this framework, a unique HPLC method was successfully established and validated for ursodeoxycholic (UDCA), chenodeoxycholic (CDCA), deoxycholic (DCA) and cholic (CA) acids, as well as the corresponding glyco- and tauro-conjugated forms. Because of the shared absence of relevant chromophoric moieties in the sample structure, an evaporative light scattering detector (ELSD) was profitably utilized for the analysis of such steroidal species. For each of the investigated compounds, all the runs were contemporarily carried out on the acidic free and the two relative conjugated variants. The different ELSD response of the free and the corresponding conjugated BAs, imposed to build-up separate calibration curves. In all the cases, very good precision (RSD% values ranging from 1.04 to 6.40% in the long-period) and accuracy (Recovery% values ranging from 96.03 to 111.14% in the long-period) values along with appreciably low LOD and LOQ values (the former being within the range 1-27 ng mL(-1) and the latter within the range 2-44 ng mL(-1)) turned out. Copyright © 2012 Elsevier B.V. All rights reserved.
Robbins, Rebecca J; Leonczak, Jadwiga; Li, Julia; Johnson, J Christopher; Collins, Tom; Kwik-Uribe, Catherine; Schmitz, Harold H
2013-01-01
An international collaborative study was conducted on an HPLC method with fluorescent detection for the determination of flavanols and procyanidins in chocolate and cocoa-containing materials. The sum of the oligomeric fractions with degree of polymerization 1-10 was the determined content value. Sample materials included dark and milk chocolates, cocoa powder, cocoa liquors, and cocoa extracts. The content ranged from approximately 2 to 500 mg/g (defatted basis). Thirteen laboratories--representing commercial, industrial, and academic institutions in six countries--participated in this interlaboratory study. Fourteen samples were sent as blind duplicates to the collaborators. Results for 12 laboratories yielded repeatability RSD (RSDr) values below 10% for all materials analyzed, ranging from 4.17 to 9.61%. Reproducibility RSD (RSDR) values ranged from 5.03 to 12.9% for samples containing 8.07 to 484.7 mg/g material analyzed. In one sample containing a low content of flavanols and procyanidins (approximately 2 mg/g), the RSDR was 17.68%.
Neira, José L; Hornos, Felipe; Cozza, Concetta; Cámara-Artigas, Ana; Abián, Olga; Velázquez-Campoy, Adrián
2018-02-01
The phosphotransferase system (PTS) controls the preferential use of sugars in bacteria and it is also involved in other processes, such as chemotaxis. It is formed by a protein cascade in which the first two proteins are general (namely, EI and HPr) and the others are sugar-specific permeases. The Rsd protein binds specifically to the RNA polymerase (RNAP) σ 70 factor. We first characterized the conformational stability of Escherichia coli Rsd. And second, we delineated the binding regions of Streptomyces coelicolor, HPr sc , and E. coli Rsd, by using fragments derived from each protein. To that end, we used several biophysical probes, namely, fluorescence, CD, NMR, ITC and BLI. Rsd had a free energy of unfolding of 15 kcal mol -1 at 25 °C, and a thermal denaturation midpoint of 103 °C at pH 6.5. The affinity between Rsd and HPr sc was 2 μM. Interestingly enough, the isolated helical-peptides, comprising the third (RsdH3) and fourth (RsdH4) Rsd helices, also interacted with HPr sc in a specific manner, and with affinities similar to that of the whole Rsd. Moreover, the isolated peptide of HPr sc , HPr 9-30 , comprising the active site, His15, also was bound to intact Rsd with similar affinity. Therefore, binding between Rsd and HPr sc was modulated by the two helices H3 and H4 of Rsd, and the regions around the active site of HPr sc . This implies that specific fragments of Rsd and HPr sc can be used to interfere with other protein-protein interactions (PPIs) of each other protein. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vlah, Zvonimir; Seljak, Uroš; McDonald, Patrick; Okumura, Teppei; Baldauf, Tobias
2012-11-01
We develop a perturbative approach to redshift space distortions (RSD) using the phase space distribution function approach and apply it to the dark matter redshift space power spectrum and its moments. RSD can be written as a sum over density weighted velocity moments correlators, with the lowest order being density, momentum density and stress energy density. We use standard and extended perturbation theory (PT) to determine their auto and cross correlators, comparing them to N-body simulations. We show which of the terms can be modeled well with the standard PT and which need additional terms that include higher order corrections which cannot be modeled in PT. Most of these additional terms are related to the small scale velocity dispersion effects, the so called finger of god (FoG) effects, which affect some, but not all, of the terms in this expansion, and which can be approximately modeled using a simple physically motivated ansatz such as the halo model. We point out that there are several velocity dispersions that enter into the detailed RSD analysis with very different amplitudes, which can be approximately predicted by the halo model. In contrast to previous models our approach systematically includes all of the terms at a given order in PT and provides a physical interpretation for the small scale dispersion values. We investigate RSD power spectrum as a function of μ, the cosine of the angle between the Fourier mode and line of sight, focusing on the lowest order powers of μ and multipole moments which dominate the observable RSD power spectrum. Overall we find considerable success in modeling many, but not all, of the terms in this expansion. This is similar to the situation in real space, but predicting power spectrum in redshift space is more difficult because of the explicit influence of small scale dispersion type effects in RSD, which extend to very large scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vlah, Zvonimir; Seljak, Uroš; Baldauf, Tobias
We develop a perturbative approach to redshift space distortions (RSD) using the phase space distribution function approach and apply it to the dark matter redshift space power spectrum and its moments. RSD can be written as a sum over density weighted velocity moments correlators, with the lowest order being density, momentum density and stress energy density. We use standard and extended perturbation theory (PT) to determine their auto and cross correlators, comparing them to N-body simulations. We show which of the terms can be modeled well with the standard PT and which need additional terms that include higher order correctionsmore » which cannot be modeled in PT. Most of these additional terms are related to the small scale velocity dispersion effects, the so called finger of god (FoG) effects, which affect some, but not all, of the terms in this expansion, and which can be approximately modeled using a simple physically motivated ansatz such as the halo model. We point out that there are several velocity dispersions that enter into the detailed RSD analysis with very different amplitudes, which can be approximately predicted by the halo model. In contrast to previous models our approach systematically includes all of the terms at a given order in PT and provides a physical interpretation for the small scale dispersion values. We investigate RSD power spectrum as a function of μ, the cosine of the angle between the Fourier mode and line of sight, focusing on the lowest order powers of μ and multipole moments which dominate the observable RSD power spectrum. Overall we find considerable success in modeling many, but not all, of the terms in this expansion. This is similar to the situation in real space, but predicting power spectrum in redshift space is more difficult because of the explicit influence of small scale dispersion type effects in RSD, which extend to very large scales.« less
Validation of PCR methods for quantitation of genetically modified plants in food.
Hübner, P; Waiblinger, H U; Pietsch, K; Brodmann, P
2001-01-01
For enforcement of the recently introduced labeling threshold for genetically modified organisms (GMOs) in food ingredients, quantitative detection methods such as quantitative competitive (QC-PCR) and real-time PCR are applied by official food control laboratories. The experiences of 3 European food control laboratories in validating such methods were compared to describe realistic performance characteristics of quantitative PCR detection methods. The limit of quantitation (LOQ) of GMO-specific, real-time PCR was experimentally determined to reach 30-50 target molecules, which is close to theoretical prediction. Starting PCR with 200 ng genomic plant DNA, the LOQ depends primarily on the genome size of the target plant and ranges from 0.02% for rice to 0.7% for wheat. The precision of quantitative PCR detection methods, expressed as relative standard deviation (RSD), varied from 10 to 30%. Using Bt176 corn containing test samples and applying Bt176 specific QC-PCR, mean values deviated from true values by -7to 18%, with an average of 2+/-10%. Ruggedness of real-time PCR detection methods was assessed in an interlaboratory study analyzing commercial, homogeneous food samples. Roundup Ready soybean DNA contents were determined in the range of 0.3 to 36%, relative to soybean DNA, with RSDs of about 25%. Taking the precision of quantitative PCR detection methods into account, suitable sample plans and sample sizes for GMO analysis are suggested. Because quantitative GMO detection methods measure GMO contents of samples in relation to reference material (calibrants), high priority must be given to international agreements and standardization on certified reference materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tellarini, Matteo; Ross, Ashley J.; Wands, David
Measurements of the non-Gaussianity of the primordial density field have the power to considerably improve our understanding of the physics of inflation. Indeed, if we can increase the precision of current measurements by an order of magnitude, a null-detection would rule out many classes of scenarios for generating primordial fluctuations. Large-scale galaxy redshift surveys represent experiments that hold the promise to realise this goal. Thus, we model the galaxy bispectrum and forecast the accuracy with which it will probe the parameter f {sub NL}, which represents the degree of primordial local-type non Gaussianity. Specifically, we address the problem of modellingmore » redshift space distortions (RSD) in the tree-level galaxy bispectrum including f {sub NL}. We find novel contributions associated with RSD, with the characteristic large scale amplification induced by local-type non-Gaussianity. These RSD effects must be properly accounted for in order to obtain un-biased measurements of f {sub NL} from the galaxy bispectrum. We propose an analytic template for the monopole which can be used to fit against data on large scales, extending models used in the recent measurements. Finally, we perform idealised forecasts on σ {sub f} {sub N{sub L}}—the accuracy of the determination of local non-linear parameter f {sub NL}—from measurements of the galaxy bispectrum. Our findings suggest that current surveys can in principle provide f {sub NL} constraints competitive with Planck , and future surveys could improve them further.« less
Zhang, Xiaokai; Zhang, Song; Yang, Qian; Cao, Wei; Xie, Yanhua; Qiu, Pengcheng; Wang, Siwang
2015-01-01
Background: Yuanhu Zhitong prescription (YZP) is a famous traditional Chinese medicine formula, which is officially recorded in Chinese Pharmacopoeia for the treatment of stomach pain, hypochondriac pain, headache and dysmenorrhea caused by qi-stagnancy and blood stasis. It is the first report for the simultaneous determination of 12 active components in YZP. Objective: A newly, simple, accurate and reliable method for the separation and determination of 12 active components (protopine, α-allocryptopine, coptisine, xanthotol, palmatine, dehydrocorydaline, glaucine, tetrahydropalmatine, tetrahydroberberine, imperatorin, corydaline, isoimperatorin) in YZP was developed and validated using HPLC-PAD. Materials and Methods: The analytes were performed on a Phenomenex Luna-C18 (2) column (250×4.6 mm, 5.0 μm) with a gradient elution program using a mixture of acetonitrile and 0.1% phosphoric acid water solution (adjusted with triethylamine to pH 5.6) as mobile phase. Analytes were performed at 30°C with a flow rate of 1.0 mL/min. Results: The validated method was applied to analyze four major dosage forms of YZP coming from different manufacturers with good linearity (r2, 0.9981~0.9999), precision (RSD, 0.24~2.89%), repeatability (RSD, 0.15~3.34%), stability (RSD, 0.14~3.35%), recovery (91.13~110.81%) of the 12 components. Conclusion: The proposed method enables the separation and determination of 12 active components in a single run for the quality control of YZP. PMID:25709212
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patikoglou,G.; Westblade, L.; Campbell, E.
The Escherichia coli Rsd protein binds tightly and specifically to the RNA polymerase (RNAP) {sigma}{sup 70} factor. Rsd plays a role in alternative {sigma} factor-dependent transcription by biasing the competition between {sigma}{sup 70} and alternative {sigma} factors for the available core RNAP. Here, we determined the 2.6 {angstrom}-resolution X-ray crystal structure of Rsd bound to {sigma}{sup 70} domain 4 ({sigma}{sup 70}{sub 4}), the primary determinant for Rsd binding within {sigma}{sup 70}. The structure reveals that Rsd binding interferes with the two primary functions of {sigma}{sup 70}{sub 4}, core RNAP binding and promoter -35 element binding. Interestingly, the most highly conservedmore » Rsd residues form a network of interactions through the middle of the Rsd structure that connect the {sigma}{sup 70}{sub 4}-binding surface with three cavities exposed on distant surfaces of Rsd, suggesting functional coupling between {sigma}{sup 70}{sub 4} binding and other binding surfaces of Rsd, either for other proteins or for as yet unknown small molecule effectors. These results provide a structural basis for understanding the role of Rsd, as well as its ortholog, AlgQ, a positive regulator of Pseudomonas aeruginosa virulence, in transcription regulation.« less
Lee, Bohyung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je
2014-01-01
Background: Tilia amurensis consists of various compounds, such as flavonoids and terpenoids. Objective: A simple and reliable high performance liquid chromatography (HPLC) coupled with the diode array detector (DAD) method has been established for simultaneous determination of epicatechin, nudiposide, lyoniside, and scopoletin isolated from Tilia amurensis. Materials and Methods: Optimum separations were obtained with a SHISEIDO C18 column by gradient eluton, with 0.1% Trifluoroacetic acid (TFA) water-methanol as the mobile phase. The gradient elution system was completed within 40 minutes. The flow rate and detection wavelength were 1 mL/minute, 205 nm, 250 nm, and 280 nm, respectively. Results: Validation of the analytical method was evaluated by linearity, precision, and the accuracy test. The calibration curve was linear over the established range with R2 > 0.997. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.01-15.20 μg/mL and 0.03-46.06 μg/mL. The method exhibited an intraday and interday precision range of 96.25-105.66% and 93.52-109.92%, respectively (RSD <2.80%). The recoveries and relative standard deviation (RSD) of the four compounds in Tilia amurensis were in the range of 90.42-104.84% and 0.2-2.58%. Conclusion: This developed method was accurate and reliable for the quality evaluation of the four compounds isolated from Tilia amurensis. PMID:25210303
Wang, Zhaokun; Zhang, Xue; Jiang, Shenmeng; Guo, Xingjie
2018-04-01
In this work, the magnetic multiwalled carbon nanotubes (Mag-MWCNTs) were prepared by self-assembly method and characterized by scanning electron microscopy, X-ray powder diffraction, energy dispersive X-ray and vibrating sample magnetometer. Then, these synthetic Mag-MWCNTs were used as sorbents to extract five β-blockers (atenolol, metoprolol, esmolol, pindolol and arotinolol) by magnetic solid-phase extraction. The target analytes adsorbed on Mag-MWCNTs were eluted and determined on a chiral α-acid glycoprotein column coupled with a triple quadrupole mass spectrometry. Eventually, the proposed method was applied to the analysis of the enantiomeric composition of the studied β-blockers in three environmental samples, including river water, influent wastewater and effluent wastewater. Method detection and quantification limits for all enantiomers were in the range of 0.50-1.45 and 1.63-3.75ng/L, respectively. Satisfactory recovery (82.9-95.6%), good intra-day precision (RSD 0.4-10.4%) and inter-day precision (RSD 2.9-7.4%) were also obtained. With numerous advantages such as simplicity of operation, rapidity and high enrichment factor, the newly developed method has potential to assess the enantioselectivity of chiral drugs in ecotoxicity and biodegradation processes, which is also a new expanded application of Mag-MWCNTs in the environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Hongliang; Li, Yinghe; Pelzer, Mary; Cannon, Michelle J; Randlett, Christopher; Junga, Heiko; Jiang, Xiangyu; Ji, Qin C
2008-05-30
A sensitive and selective bioanalytical assay was developed and validated for the determination of enantiomeric molindone in human plasma using high-performance liquid chromatography-tandem mass spectrometry along with supported liquid extraction procedures. The chiral separation was evaluated and optimized on macrocyclic antibiotic type chiral stationary phases (CSPs) based on teicoplanin aglycone (Chirobiotic TAG) in polar organic, polar ionic, and reversed-phase mode chromatography, respectively. Complete baseline separation was achieved on a Chirobiotic TAG column under isocratic condition in reversed-phase chromatography. The method validation was conducted using a Chirobiotic TAG column (100 mm x 2.1 mm) over the curve range 0.100-100 ng/ml for each molindone enantiomer using 0.0500 ml of plasma sample. The flow rate was 0.8 ml/min and the total run time was 9 min. Supported liquid extraction in a 96-well plate format was used for sample preparation. Parameters including recovery, matrix effect, linearity, sensitivity, specificity, carryover, precision, accuracy, dilution integrity, and stability were evaluated. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels were RSD
Lee, Changgook; Lee, Younghoon; Lee, Jae-Gon; Buglass, Alan J
2013-06-21
A simultaneous multiple solid-phase microextraction-single shot-gas chromatography mass spectrometry (smSPME-ss-GC/MS) method has been developed for headspace analysis. Up to four fibers (50/30 μm DVB/CAR/PDMS) were used simultaneously for the extraction of aroma components from the headspace of a single sample chamber in order to increase sensitivity of aroma extraction. To avoid peak broadening and to maximize resolution, a simple cryofocusing technique was adopted during sequential thermal desorption of multiple SPME fibers prior to a 'single shot' chromatographic run. The method was developed and validated on a model flavor mixture, containing 81 known pure components. With the conditions of 10 min of incubation and 30 min of extraction at 50 °C, single, dual, triple and quadruple SPME extractions were compared. The increase in total peak area with increase in the number of fibers showed good linearity (R(2)=0.9917) and the mean precision was 12.0% (RSD) for the total peak sum, with quadruple simultaneous SPME extraction. Using a real sample such as commercial coffee granules, aroma profile analysis was conducted using single, dual, triple and quadruple SPME fibers. The increase in total peak intensity again showed good linearity with increase in the number of SPME fibers used (R(2)=0.9992) and the precision of quadruple SPME extraction was 9.9% (RSD) for the total peak sum. Copyright © 2013 Elsevier B.V. All rights reserved.
Novel approaches to analysis by flow injection gradient titration.
Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł
2007-09-26
Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.
Mezouari, S; Liu, W Yun; Pace, G; Hartman, T G
2015-01-01
The objective of this study was to develop an improved analytical method for the determination of 3-chloro-1,2-propanediol (3-MCPD) and 1,3-dichloropropanol (1,3-DCP) in paper-type food packaging. The established method includes aqueous extraction, matrix spiking of a deuterated surrogate internal standard (3-MCPD-d₅), clean-up using Extrelut solid-phase extraction, derivatisation using a silylation reagent, and GC-MS analysis of the chloropropanols as their corresponding trimethyl silyl ethers. The new method is applicable to food-grade packaging samples using European Commission standard aqueous extraction and aqueous food stimulant migration tests. In this improved method, the derivatisation procedure was optimised; the cost and time of the analysis were reduced by using 10 times less sample, solvents and reagents than in previously described methods. Overall the validation data demonstrate that the method is precise and reliable. The limit of detection (LOD) of the aqueous extract was 0.010 mg kg(-1) (w/w) for both 3-MCPD and 1,3-DCP. Analytical precision had a relative standard deviation (RSD) of 3.36% for 3-MCPD and an RSD of 7.65% for 1,3-DCP. The new method was satisfactorily applied to the analysis of over 100 commercial paperboard packaging samples. The data are being used to guide the product development of a next generation of wet-strength resins with reduced chloropropanol content, and also for risk assessments to calculate the virtual safe dose (VSD).
Daniele, Gaëlle; Lafay, Florent; Pelosi, Céline; Fritsch, Clémentine; Vulliet, Emmanuelle
2018-06-04
Agricultural intensification, and in particular the use of pesticides, leads over the years to a loss of biodiversity and a decline of ecosystem services in cultivated zones and agricultural landscapes. Among the animal communities involved in the functioning of agro-ecosystems, earthworms are ubiquitous and recognized as indicators of land uses and cultural practices. However, little data is available on the levels of pesticides in such organisms in natura, which would allow estimating their actual exposure and the potentially resulting impacts. Thus, the objective of this study was to develop a sensitive analytical methodology to detect and quantify 27 currently used pesticides in earthworms (Allolobophora chlorotica). A modified QuEChERS extraction was implemented on individual earthworms. This step was followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The whole analytical method was validated on spiked earthworm blank samples, with regard to linearity (from 1 to 100 method limit of quantification, r 2 > 0.95), intra-day precision (relative standard deviation (RSD) < 15%), inter-day precision (RSD < 20%), recoveries (mainly in the range 70-110%), and limits of detection and of quantification (inferior to 5 ng/g for most of the pesticides). The developed method was successfully applied to determine the concentrations of pesticides in nine individuals collected in natura. Up to five of the selected pesticides have been detected in one individual. Graphical abstract.
Cheng, Zhipeng; Dong, Fengshou; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Chen, Zenglong; Pan, Xinglu; Zheng, Yongquan
2016-02-26
In this study, the application of atmospheric pressure gas chromatography quadrupole-time-of-flight mass spectrometry (APGC-QTOF-MS) has been investigated for simultaneous determination of fifteen organochlorine pesticides in soil and water. Soft ionization of atmospheric pressure gas chromatography was evaluated by comparing with traditional more energetic electron impact ionization (EI). APGC-QTOF-MS showed a sensitivity enhancement by approximately 7-305 times. The QuEChERs (Quick, Easy, Cheap, Effective, Rugged, and Safe) method was used to pretreat the soil samples and solid phase extraction (SPE) cleanup was used for water samples. Precision, accuracy and stability experiments were undertaken to evaluate the feasibility of the method. The results showed that the mean recoveries for all the pesticides from the soil samples were 70.3-118.9% with 0.4-18.3% intra-day relative standard deviations (RSD) and 1.0-15.6% inter-day RSD at 10, 50 and 500 μg/L levels, while the mean recoveries of water samples were 70.0-118.0% with 1.1-17.8% intra-day RSD and 0.5-12.2% inter-day RSD at 0.1, 0.5 and 1.0 μg/L levels. Excellent linearity (0.9931 ≦ r(2)≤ 0.9999) was obtained for each pesticides in the soil and water matrix calibration curves within the range of 0.01-1.0mg/L. The limits of detection (LOD) for each of the 15 pesticides was less than 3.00 μg/L, while the limit of quantification (LOQ) was less than 9.99 μg/L in soil and water. Furthermore, the developed method was successfully applied to monitor the targeted pesticides in real soil and water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bamberger, Judith A.; Piepel, Gregory F.; Enderlin, Carl W.
Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests weremore » conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.« less
Kostić, Marina; Djakovic, Ljiljan; Šujić, Raša; Godman, Brian; Janković, Slobodan M
2017-02-01
Although the costs of treating inflammatory bowel disease (IBD) in developed countries are well established, they remain largely unknown in countries with recent histories of socio-economic transition including Serbia. To estimate the costs of treatment including the resources used by patients with IBD in Serbia from a societal perspective. This includes both Crohn's disease and ulcerative colitis. This cost-of-illness study was conducted to identify direct, indirect and out-of-pocket costs of treating patients with IBD in Serbia. Patients with IBD (n = 112) completed a semi-structured questionnaire with data concerning their utilisation of heath-care resources and illness-related expenditures. All costs were calculated in Republic of Serbia dinars (RSD) at a 1-year level (2014) and subsequently converted to Euros. Median values and ranges were reported to avoid potential distortions associated with mean costs. Median total direct costs and total indirect costs per patient per year in patients with Crohn's disease were 192,614.32RSD (€1602.97) and 28,014.00RSD (€233.13) and 142,267.15RSD (€1183.97) and 21,436.00RSD (€178.39), respectively, in patients with ulcerative colitis. In both groups, the greatest component of direct costs was hospitalisation. Costs of IBD in Serbia are lower than in more developed countries for two reasons. These include the fact that expensive biological therapy is currently under-utilised in Serbia and prices of health services are largely controlled by the State at a low level. The under-utilisation of biologicals may change with the advent of biosimilars at increasingly lower prices.
NASA Astrophysics Data System (ADS)
Janapati, Jayalakshmi; seela, Balaji Kumar; Reddy M., Venkatrami; Reddy K., Krishna; Lin, Pay-Liam; Rao T., Narayana; Liu, Chian-Yi
2017-06-01
Raindrop size distribution (RSD) characteristics in before landfall (BLF) and after landfall (ALF) of three tropical cyclones (JAL, THANE, and NILAM) induced precipitations are investigated by using a laser-based (PARticleSIze and VELocity - PARSIVEL) disdrometer at two different locations [Kadapa (14.47°N, 78.82°E) and Gadanki (13.5°N, 79.2°E)] in semi-arid region of southern India. In both BLF and ALF precipitations of these three cyclones, convective precipitations have higher mass weighted mean diameter (Dm) and lower normalized intercept parameter (log10Nw) values than stratiform precipitations. The radar reflectivity (Z) and rain rate (R) relations (Z=A*Rb) showed distinct variations in BLF and ALF precipitations of three cyclones. BLF precipitation of JAL cyclone has a higher Dm than ALF precipitation. Whereas, for THANE and NILAM cyclones ALF precipitations have higher Dm than BLF. The Dm values of three cyclones (both in BLF and ALF) are smaller than the Dm values of the other (Atlantic and Pacific) oceanic cyclones. Interaction of different regions (eyewall, inner rainbands, and outer rainbands) of cyclones with the environment and underlying surface led to RSD variations between BLF and ALF precipitations through different microphysical (collision-coalescence, breakup, evaporation, and riming) processes. The immediate significance of the present work is that (i) it contributes to our understanding of cyclone RSD in BLF and ALF precipitations, and (ii) it provides the useful information for quantitative estimation of rainfall from Doppler weather radar observations.
Jishage, M; Ishihama, A
1999-06-01
The regulator of sigma D (Rsd) was identified as an RNA polymerase sigma70-associated protein in stationary-phase Escherichia coli with the inhibitory activity of sigma70-dependent transcription in vitro (M. Jishage and A. Ishihama, Proc. Natl. Acad. Sci. USA 95:4953-4958, 1998). Primer extension analysis of rsd mRNA indicated the presence of two promoters, sigmaS-dependent P1 and sigma70-dependent P2 with the gearbox sequence. To get insight into the in vivo role of Rsd, the expression of a reporter gene fused to either the sigma70- or sigmaS-dependent promoter was analyzed in the absence of Rsd or the presence of overexpressed Rsd. In the rsd null mutant, the sigma70- and sigmaS-dependent gene expression was increased or decreased, respectively. On the other hand, the sigma70- or sigmaS-dependent transcription was reduced or enhanced, respectively, after overexpression of Rsd. The repression of the sigmaS-dependent transcription in the rsd mutant is overcome by increased production of the sigmaS subunit. Together these observations support the prediction that Rsd is involved in replacement of the RNA polymerase sigma subunit from sigma70 to sigmaS during the transition from exponential growth to the stationary phase.
Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein
2017-08-01
A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Ozbek, Nil; Akman, Suleyman
The presence of fluorine (F) was detected via the rotational molecular absorption line of diatomic strontium-monofluoride (SrF) generated in the gas phase at 651.187 nm using high-resolution continuum source electrothermal atomic absorption spectrometry. Upon the addition of excess strontium (Sr) as the nitrate, the fluorine in the sample was converted to SrF in the gas phase of a graphite furnace. The effects on the accuracy, precision and sensitivity of variables such as the SrF wavelength, graphite furnace program, amount of Sr, coating of the graphite tube and platform with Zr and Ir and the use of a modifier were investigated and optimized. It was determined that there was no need to use a modifier or to cover the platform/tubes with Zr or Ir. Fluorine concentrations in various water samples (certified waste water, tap water, drinking water and mineral water) were determined using 20 μg of Sr as the molecule-forming reagent and applying a maximum pyrolysis temperature of 800 °C and a molecule-forming temperature of 2200 °C with a heating rate of 2000 °C s- 1. Good linearity was maintained up to 0.1 μg of F. The accuracy and precision of the method were tested by analyzing certified reference wastewater. The results were in good agreement with certified values, and the precision was satisfactory (RSD < 10%). The limit of detection and the characteristic mass for the method were 0.36 ng and 0.55 ng, respectively. Finally, the fluorine concentrations in several drinking water and mineral water samples taken from the market were determined. The results were in good agreement with the values supplied by the producers. No significant differences were found between the results from the linear calibration and standard addition techniques. The method was determined to be simple, fast, accurate and sensitive.
Huang, Xinqi; Liu, Liangliang; Wen, Teng; Zhang, Jinbo; Wang, Fenghe; Cai, Zucong
2016-06-01
Reductive soil disinfestation (RSD) has been proven to be an effective and environmentally friendly way to control many soilborne pathogens and diseases. In this study, the RSDs using ethanol (Et-RSD) and alfalfa (Al-RSD) as organic carbons were performed in a Rhizoctonia solani-infected soil, and the dissimilarities of microbial communities during the RSDs and after planting two seasons of cucumber seedlings in the RSDs-treated soil were respectively investigated by MiSeq pyrosequencing. The results showed that, as for bacteria, Coprococcus, Flavisolibacter, Rhodanobacter, Symbiobacterium, and UC-Ruminococcaceae became the dominant bacterial genera at the end of Al-RSD. In contrast, Et-RSD soil involved more bacteria belonging to Firmicutes, such as Sedimentibacter, UC-Gracilibacteraceae, and Desulfosporosinus. For fungi, Chaetomium significantly increased at the end of RSDs, while Rhizoctonia and Aspergillus significantly decreased. After planting two seasons of cucumber seedlings, those bacteria belonging to Firmicutes significantly decreased, but Lysobacter and Rhodanobacter belonging to the phylum Proteobacteria as well as UC-Sordariales and Humicola belonging to Ascomycota alternatively increased in Al- and Et-RSD-treated soils. Besides, some nitrification, denitrification, and nitrogen fixation genes were apparently increased in the RSD-treated soils, but the effect was more profound in Al-RSD than Et-RSD. Overall, Et-RSD could induced more antagonists belonging to Firmicutes under anaerobic condition, whereas Al-RSD could continuously stimulate some functional microorganisms (Lysobacter and Rhodanobacter) and further improve nitrogen transformation activities in the soil at the coming cropping season.
Takabatake, Reona; Koiwa, Tomohiro; Kasahara, Masaki; Takashima, Kaori; Futo, Satoshi; Minegishi, Yasutaka; Akiyama, Hiroshi; Teshima, Reiko; Oguchi, Taichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi
2011-01-01
To reduce the cost and time required to routinely perform the genetically modified organism (GMO) test, we developed a duplex quantitative real-time PCR method for a screening analysis simultaneously targeting an event-specific segment for GA21 and Cauliflower Mosaic Virus 35S promoter (P35S) segment [Oguchi et al., J. Food Hyg. Soc. Japan, 50, 117-125 (2009)]. To confirm the validity of the method, an interlaboratory collaborative study was conducted. In the collaborative study, conversion factors (Cfs), which are required to calculate the GMO amount (%), were first determined for two real-time PCR instruments, the ABI PRISM 7900HT and the ABI PRISM 7500. A blind test was then conducted. The limit of quantitation for both GA21 and P35S was estimated to be 0.5% or less. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSD(R)). The determined bias and RSD(R) were each less than 25%. We believe the developed method would be useful for the practical screening analysis of GM maize.
Gollapudi, Deepika; Wycuff, Diane L; Schwartz, Richard M; Cooper, Jonathan W; Cheng, K C
2017-10-01
In this paper, we describe development of a high-throughput, highly sensitive method based on Lab Chip CGE-SDS platform for purity determination and characterization of virus-like particle (VLP) vaccines. A capillary gel electrophoresis approach requiring about 41 s per sample for analysis and demonstrating sensitivity to protein initial concentrations as low as 20 μg/mL, this method has been used previously to evaluate monoclonal antibodies, but this application for lot release assay of VLPs using this platform is unique. The method was qualified and shown to be accurate for the quantitation of VLP purity. Assay repeatability was confirmed to be less than 2% relative standard deviation of the mean (% RSD) with interday precision less than 2% RSD. The assay can evaluate purified VLPs in a concentration range of 20-249 μg/mL for VEE and 20-250 μg/mL for EEE and WEE VLPs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ehling, Stefan; Reddy, Todime M
2014-02-19
A simple, rugged, quantitative, and confirmatory method based on liquid chromatography-mass spectrometry was developed and comprehensively validated for the analysis of the leucine metabolites β-hydroxy-β-methylbutyric acid (HMB) and α-hydroxyisocaproic acid (HICA) in bovine whole milk and yogurt. Mean accuracy (90-110% for HMB and 85-115% for HICA) and total precision (<10% RSD in most cases, except for <20% RSD for HMB at the limit of quantitation) at four concentration levels across three validation runs have been determined. Limits of quantitation for HMB and HICA in whole milk were 20 and 5 μg/L, respectively. Measured concentrations of HMB and HICA were <20-29 and 32-37 μg/L, respectively, in bovine whole milk and <5 and 3.0-15.2 mg/L, respectively, in yogurt. These concentrations are insufficient by large margins to deliver any musculoskeletal benefits, and fortification of milk and dairy products with HMB and/or HICA appears to be justified.
Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca
2005-02-15
A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.
Rapid Analysis of Trace Drugs and Metabolites Using a Thermal Desorption DART-MS Configuration.
Sisco, Edward; Forbes, Thomas P; Staymates, Matthew E; Gillen, Greg
2016-01-01
The need to analyze trace narcotic samples rapidly for screening or confirmatory purposes is of increasing interest to the forensic, homeland security, and criminal justice sectors. This work presents a novel method for the detection and quantification of trace drugs and metabolites off of a swipe material using a thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS) configuration. A variation on traditional DART, this configuration allows for desorption of the sample into a confined tube, completely independent of the DART source, allowing for more efficient and thermally precise analysis of material present on a swipe. Over thirty trace samples of narcotics, metabolites, and cutting agents deposited onto swipes were rapidly differentiated using this methodology. The non-optimized method led to sensitivities ranging from single nanograms to hundreds of picograms. Direct comparison to traditional DART with a subset of the samples highlighted an improvement in sensitivity by a factor of twenty to thirty and an increase in reproducibility sample to sample from approximately 45 % RSD to less than 15 % RSD. Rapid extraction-less quantification was also possible.
Zhu, Shanshan; Hu, Futao; Yang, Ting; Gan, Ning; Pan, Daodong; Cao, Yuting; Wu, Dazhen
2013-03-15
Analysis of tributyltin chloride (TBT) in environmental samples, such as seawater, is important in order to evaluate the TBT contamination and accumulation in the trophic chain. The environmental impact of organotin compounds has been a particular focus of analytical studies. The present study reports the use of molecular imprinting technology coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine trace amounts of TBT in seawater and seafood (mussel tissue samples). The imprinted polymer was synthesized by a non-covalent free-radical approach using acrylamide (AM) as a monomer and TBT as a template molecule in acetonitrile solvent (polymerization media). The imprinted polymer synthesized by this approach exhibited good adsorptive capacity and allowed specific retention of TBT. Recoveries of TBT in seawater samples spiked with different TBT concentrations ranged from 67.2% to 81.1% with peak area precision (RSD)<3.7%, and recoveries of TBT in mussel tissue samples ranged from 75.0% to 94.2% with RSD<4.8%. Copyright © 2013 Elsevier B.V. All rights reserved.
Vichi, Stefania; Cortés-Francisco, Nuria; Caixach, Josep
2015-05-15
A simultaneous derivatization/extraction method followed by liquid chromatography-electrospray-high resolution mass spectrometry for the determination of volatile thiols in hydroalcoholic matrixes was optimized and used to identify and quantify volatile thiols in wine and beer samples. The method was evaluated in terms of sensitivity, precision, accuracy and selectivity. The experimental LOQs of eleven thiols tested ranged between 0.01 ng/L and 10 ng/L. Intra-day relative standard deviation (RSD) was in general lower than 10% and inter-day RSD ranged between 10% and 30%. Recovery in the model and real matrixes ranged from 45% to 129%. The method was then applied for the analysis of four white wines and six beers. Five out of the eleven reference thiols were identified and quantified in the samples analyzed. The non-target approach, carried out by monitoring the diagnostic ion at m/z 275.9922 [C13H10ONSe](+) in the fragmentation spectrum, allowed detecting, in the same samples, fourteen non-target thiols. Copyright © 2014 Elsevier Ltd. All rights reserved.
Azeem, Sami M Abdel; Hanafi, Hassan A; El-Shahat, M F
2015-01-01
A fast and sensitive on-line procedure for the determination of zinc in water and biological samples was developed. Zinc was preconcentrated in a mini-column packed with polyurethane foam (PUF) chemically modified with zincon via -N=N- bonding. The optimal conditions for preconcentration were pH 8.5 and sample flow rate of 4.0 mL min(-1). Quantitative desorption of Zn(II) was obtained by 0.1 mol L(-1) hydrochloric acid and subsequent spectrophotmetric determination using 4-(2-pyridylazo)-resorcinol at 498 nm. The obtained detection limit was found to be 3.0 ng mL(-1), precision (RSD) was 4.8 and 6.7% at 20 and 110 ng mL(-1), respectively, for 60 s preconcentration time and enrichment factor was 31. The linearity range was from 10 to 120 ng mL(-1) and maximum sample throughput was 20 h(-1). Finally, the method was successfully applied to the determination of zinc in tap water, Nile River water and human urine samples with RSD in the range of 1.1 - 8.3%.
Wang, Ning; Su, Ming; Liang, Shuxuan; Sun, Hanwen
2016-05-15
A rapid and effective method for effective separation and rapid simultaneous determination of six bioactive anthraquinones by capillary zone electrophoresis was developed. An accelerated solvent extraction procedure was used for the extraction of anthraquinones from slimming tea. Under the optimized conditions, the effective separation of six anthraquinones was achieved within 8 min. Good linearity was achieved, with a correlation coefficient (r) of ⩾ 0.999. The limit of detection ranged from 0.33 to 1.40 μg mL(-1). The intra- and inter-day relative standard deviation (RSD) of the six analytes was in the range of 2.3-3.9% and 3.2-4.9%, respectively. The average recovery of the six analytes from real tea samples was in the range of 86.15-98.30% with the RSD of 1.04-4.99%. The developed and validated method has speediness, high sensitivity, recovery and precision, and can be applied for the quality control of slimming tea. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mitchell, Jennie E; Oshima, Taku; Piper, Sarah E; Webster, Christine L; Westblade, Lars F; Karimova, Gouzel; Ladant, Daniel; Kolb, Annie; Hobman, Jon L; Busby, Stephen J W; Lee, David J
2007-05-01
The Escherichia coli Rsd protein forms complexes with the RNA polymerase sigma(70) factor, but its biological role is not understood. Transcriptome analysis shows that overexpression of Rsd causes increased expression from some promoters whose expression depends on the alternative sigma(38) factor, and this was confirmed by experiments with lac fusions at selected promoters. The LP18 substitution in Rsd increases the Rsd-dependent stimulation of these promoter-lac fusions. Analysis with a bacterial two-hybrid system shows that the LP18 substitution in Rsd increases its interaction with sigma(70). Our experiments support a model in which the role of Rsd is primarily to sequester sigma(70), thereby increasing the levels of RNA polymerase containing the alternative sigma(38) factor.
The E. coli Anti-Sigma Factor Rsd: Studies on the Specificity and Regulation of Its Expression
Hofmann, Nina; Wurm, Reinhild; Wagner, Rolf
2011-01-01
Background Among the seven different sigma factors in E. coli σ70 has the highest concentration and affinity for the core RNA polymerase. The E. coli protein Rsd is regarded as an anti-sigma factor, inhibiting σ70-dependent transcription at the onset of stationary growth. Although binding of Rsd to σ70 has been shown and numerous structural studies on Rsd have been performed the detailed mechanism of action is still unknown. Methodology/Principal Findings We have performed studies to unravel the function and regulation of Rsd expression in vitro and in vivo. Cross-linking and affinity binding revealed that Rsd is able to interact with σ70, with the core enzyme of RNA polymerase and is able to form dimers in solution. Unexpectedly, we find that Rsd does also interact with σ38, the stationary phase-specific sigma factor. This interaction was further corroborated by gel retardation and footprinting studies with different promoter fragments and σ38- or σ70-containing RNA polymerase in presence of Rsd. Under competitive in vitro transcription conditions, in presence of both sigma factors, a selective inhibition of σ70-dependent transcription was prevailing, however. Analysis of rsd expression revealed that the nucleoid-associated proteins H-NS and FIS, StpA and LRP bind to the regulatory region of the rsd promoters. Furthermore, the major promoter P2 was shown to be down-regulated in vivo by RpoS, the stationary phase-specific sigma factor and the transcription factor DksA, while induction of the stringent control enhanced rsd promoter activity. Most notably, the dam-dependent methylation of a cluster of GATC sites turned out to be important for efficient rsd transcription. Conclusions/Significance The results contribute to a better understanding of the intricate mechanism of Rsd-mediated sigma factor specificity changes during stationary phase. PMID:21573101
The E. coli anti-sigma factor Rsd: studies on the specificity and regulation of its expression.
Hofmann, Nina; Wurm, Reinhild; Wagner, Rolf
2011-05-06
Among the seven different sigma factors in E. coli σ(70) has the highest concentration and affinity for the core RNA polymerase. The E. coli protein Rsd is regarded as an anti-sigma factor, inhibiting σ(70)-dependent transcription at the onset of stationary growth. Although binding of Rsd to σ(70) has been shown and numerous structural studies on Rsd have been performed the detailed mechanism of action is still unknown. We have performed studies to unravel the function and regulation of Rsd expression in vitro and in vivo. Cross-linking and affinity binding revealed that Rsd is able to interact with σ(70), with the core enzyme of RNA polymerase and is able to form dimers in solution. Unexpectedly, we find that Rsd does also interact with σ(38), the stationary phase-specific sigma factor. This interaction was further corroborated by gel retardation and footprinting studies with different promoter fragments and σ(38)- or σ(70)-containing RNA polymerase in presence of Rsd. Under competitive in vitro transcription conditions, in presence of both sigma factors, a selective inhibition of σ(70)-dependent transcription was prevailing, however. Analysis of rsd expression revealed that the nucleoid-associated proteins H-NS and FIS, StpA and LRP bind to the regulatory region of the rsd promoters. Furthermore, the major promoter P2 was shown to be down-regulated in vivo by RpoS, the stationary phase-specific sigma factor and the transcription factor DksA, while induction of the stringent control enhanced rsd promoter activity. Most notably, the dam-dependent methylation of a cluster of GATC sites turned out to be important for efficient rsd transcription. The results contribute to a better understanding of the intricate mechanism of Rsd-mediated sigma factor specificity changes during stationary phase.
Lisboa, Sabrina Francesca; Niraula, Anzela; Resstel, Leonardo Barbosa; Guimaraes, Francisco Silveira; Godbout, Jonathan P; Sheridan, John F
2018-04-17
Psychosocial stress contributes to the development of psychiatric disorders. Repeated social defeat (RSD) is a murine stressor that causes a release of inflammatory monocytes into circulation. Moreover, RSD-induced anxiety-like behavior is dependent on the recruitment of these monocytes to the brain. Activation of the endocannabinoid (ECB) system may modulate both neuroendocrine and inflammatory responses mediated by stress. Therefore, we hypothesized that a cannabinoid receptor agonist would attenuate RSD-induced inflammation, anxiety, and stress sensitization. To test this hypothesis, mice received an injection of the synthetic cannabinoid 1/2 receptor agonist, WIN55,212-2 (WIN; 1 mg/kg, intraperitoneally) daily for six consecutive days, 30 min before each exposure to RSD. Anxiety-like behavior, immune activation, neuroinflammation, and microglial reactivity were determined 14 h after RSD. RSD-induced anxiety-like behavior in the open field and in the EPM was reversed by WIN55,212-2. Moreover, WIN55,212-2 reduced the accumulation of inflammatory monocytes in circulation and brain after RSD and attenuated RSD-induced interleukin-1β (IL-1β) messenger RNA (mRNA) expression in microglia/macrophages. Increased ex vivo reactivity of microglia/monocytes to lipopolysaccharides (LPS) after RSD was also attenuated by WIN55,212-2. Next, fear expression, extinction, and recall were evaluated 24 and 48 h, respectively, after contextual fear conditioning, which took place 7 days after RSD. Here, RSD caused prolonged fear expression and impaired fear extinction recall, which was associated with increased IL-1β mRNA in the brain. Moreover, these stress-induced effects were reversed by WIN55,212-2. In conclusion, activation of cannabinoid receptors limited the immune and neuroinflammatory responses to RSD and reversed the short-term and long-term behavioral deficits associated with RSD.
Croft, Daniel E; van Hemert, Jano; Wykoff, Charles C; Clifton, David; Verhoek, Michael; Fleming, Alan; Brown, David M
2014-01-01
Accurate quantification of retinal surface area from ultra-widefield (UWF) images is challenging due to warping produced when the retina is projected onto a two-dimensional plane for analysis. By accounting for this, the authors sought to precisely montage and accurately quantify retinal surface area in square millimeters. Montages were created using Optos 200Tx (Optos, Dunfermline, U.K.) images taken at different gaze angles. A transformation projected the images to their correct location on a three-dimensional model. Area was quantified with spherical trigonometry. Warping, precision, and accuracy were assessed. Uncorrected, posterior pixels represented up to 79% greater surface area than peripheral pixels. Assessing precision, a standard region was quantified across 10 montages of the same eye (RSD: 0.7%; mean: 408.97 mm(2); range: 405.34-413.87 mm(2)). Assessing accuracy, 50 patients' disc areas were quantified (mean: 2.21 mm(2); SE: 0.06 mm(2)), and the results fell within the normative range. By accounting for warping inherent in UWF images, precise montaging and accurate quantification of retinal surface area in square millimeters were achieved. Copyright 2014, SLACK Incorporated.
Wang, Ludi; Yang, Wei; Wu, Siyang; Wang, Shuyao; Kang, Chen; Ma, Xiaoli; Li, Yingfei; Li, Chuan
2018-05-01
Isochamaejasmin, neochamaejasmin A and daphnoretin derived from Stellera chamaejasme L. are important because of their reported anticancer properties. In this study, a sensitive UPLC-MS/MS method for the determination of isochamaejasmin, neochamaejasmin A and daphnoretin in rat plasma was developed. The analyte and IS were separated on an Acquity UPLC HSS T3 column (100 × 2.1 mm, 1.8 μm) using gradient elution with the mobile phase of aqueous solution (methanol-water, 1:99, v/v, containing 1 mm formic acid) and organic solution (methanol-water, 99:1, v/v, containing 1 mm formic acid) at a flow rate of 0.3 mL/min. Multiple reaction monitoring mode with negative electrospray ionization interface was carried out to detect the components. The method was validated in terms of specificity, linearity, accuracy, precision, stability, etc. Excellent linear behavior was observed over the certain concentration ranges with the correlation coefficient values >0.99. Intra- and inter-day precisions (RSD) were <6.7% and accuracy (RE) ranged from -7.0 to 12.0%. The validated method was successfully applied to investigate the pharmacokinetics of three chemical ingredients after oral administration of S. chamaejasme L. extract to rats. Copyright © 2017 John Wiley & Sons, Ltd.
Mapping of the Rsd Contact Site on the Sigma 70 Subunit of Escherichia coli RNA Polymerase
Jishage, Miki; Dasgupta, Dipak; Ishihama, Akira
2001-01-01
Rsd (regulator of sigma D) is an anti-sigma factor for the Escherichia coli RNA polymerase ς70 subunit. The contact site of Rsd on ς70 was analyzed after mapping of the contact-dependent cleavage sites by Rsd-tethered iron-p-bromoacetamidobenzyl EDTA and by analysis of the complex formation between Ala-substituted ς70 and Rsd. Results indicate that the Rsd contact site is located downstream of the promoter −35 recognition helix-turn-helix motif within region 4, overlapping with the regions involved in interaction with both core enzyme and ς70 contact transcription factors. PMID:11292818
Mapping of the Rsd contact site on the sigma 70 subunit of Escherichia coli RNA polymerase.
Jishage, M; Dasgupta, D; Ishihama, A
2001-05-01
Rsd (regulator of sigma D) is an anti-sigma factor for the Escherichia coli RNA polymerase sigma(70) subunit. The contact site of Rsd on sigma(70) was analyzed after mapping of the contact-dependent cleavage sites by Rsd-tethered iron-p-bromoacetamidobenzyl EDTA and by analysis of the complex formation between Ala-substituted sigma(70) and Rsd. Results indicate that the Rsd contact site is located downstream of the promoter -35 recognition helix-turn-helix motif within region 4, overlapping with the regions involved in interaction with both core enzyme and sigma(70) contact transcription factors.
Studies of the Escherichia coli Rsd-sigma70 complex.
Westblade, Lars F; Ilag, Leopold L; Powell, Andrew K; Kolb, Annie; Robinson, Carol V; Busby, Stephen J W
2004-01-16
Escherichia coli Rsd protein was previously identified on the basis of its binding to the RNA polymerase sigma(70) subunit. The Rsd-sigma(70) complex has been studied using different methods. Our data show that Rsd associates with sigma(70) to form a complex with a stoichiometry of 1:1. Alanine scanning and deletion mutagenesis were used to locate regions of sigma(70) that are required for the formation of the Rsd-sigma(70) complex.
Sinharoy, Senjuti; Torres-Jerez, Ivone; Bandyopadhyay, Kaustav; Kereszt, Attila; Pislariu, Catalina I.; Nakashima, Jin; Benedito, Vagner A.; Kondorosi, Eva; Udvardi, Michael K.
2013-01-01
Transcription factors (TFs) are thought to regulate many aspects of nodule and symbiosis development in legumes, although few TFs have been characterized functionally. Here, we describe REGULATOR OF SYMBIOSOME DIFFERENTIATION (RSD) of Medicago truncatula, a member of the Cysteine-2/Histidine-2 (C2H2) family of plant TFs that is required for normal symbiosome differentiation during nodule development. RSD is expressed in a nodule-specific manner, with maximal transcript levels in the bacterial invasion zone. A tobacco (Nicotiana tabacum) retrotransposon (Tnt1) insertion rsd mutant produced nodules that were unable to fix nitrogen and that contained incompletely differentiated symbiosomes and bacteroids. RSD protein was localized to the nucleus, consistent with a role of the protein in transcriptional regulation. RSD acted as a transcriptional repressor in a heterologous yeast assay. Transcriptome analysis of an rsd mutant identified 11 genes as potential targets of RSD repression. RSD interacted physically with the promoter of one of these genes, VAMP721a, which encodes vesicle-associated membrane protein 721a. Thus, RSD may influence symbiosome development in part by repressing transcription of VAMP721a and modifying vesicle trafficking in nodule cells. This establishes RSD as a TF implicated directly in symbiosome and bacteroid differentiation and a transcriptional regulator of secretory pathway genes in plants. PMID:24082011
Sinharoy, Senjuti; Torres-Jerez, Ivone; Bandyopadhyay, Kaustav; Kereszt, Attila; Pislariu, Catalina I; Nakashima, Jin; Benedito, Vagner A; Kondorosi, Eva; Udvardi, Michael K
2013-09-01
Transcription factors (TFs) are thought to regulate many aspects of nodule and symbiosis development in legumes, although few TFs have been characterized functionally. Here, we describe regulator of symbiosome differentiation (RSD) of Medicago truncatula, a member of the Cysteine-2/Histidine-2 (C2H2) family of plant TFs that is required for normal symbiosome differentiation during nodule development. RSD is expressed in a nodule-specific manner, with maximal transcript levels in the bacterial invasion zone. A tobacco (Nicotiana tabacum) retrotransposon (Tnt1) insertion rsd mutant produced nodules that were unable to fix nitrogen and that contained incompletely differentiated symbiosomes and bacteroids. RSD protein was localized to the nucleus, consistent with a role of the protein in transcriptional regulation. RSD acted as a transcriptional repressor in a heterologous yeast assay. Transcriptome analysis of an rsd mutant identified 11 genes as potential targets of RSD repression. RSD interacted physically with the promoter of one of these genes, VAMP721a, which encodes vesicle-associated membrane protein 721a. Thus, RSD may influence symbiosome development in part by repressing transcription of VAMP721a and modifying vesicle trafficking in nodule cells. This establishes RSD as a TF implicated directly in symbiosome and bacteroid differentiation and a transcriptional regulator of secretory pathway genes in plants.
Mitchell, Jennie E.; Oshima, Taku; Piper, Sarah E.; Webster, Christine L.; Westblade, Lars F.; Karimova, Gouzel; Ladant, Daniel; Kolb, Annie; Hobman, Jon L.; Busby, Stephen J. W.; Lee, David J.
2007-01-01
The Escherichia coli Rsd protein forms complexes with the RNA polymerase σ70 factor, but its biological role is not understood. Transcriptome analysis shows that overexpression of Rsd causes increased expression from some promoters whose expression depends on the alternative σ38 factor, and this was confirmed by experiments with lac fusions at selected promoters. The LP18 substitution in Rsd increases the Rsd-dependent stimulation of these promoter-lac fusions. Analysis with a bacterial two-hybrid system shows that the LP18 substitution in Rsd increases its interaction with σ70. Our experiments support a model in which the role of Rsd is primarily to sequester σ70, thereby increasing the levels of RNA polymerase containing the alternative σ38 factor. PMID:17351046
Kusch, Peter; Knupp, Gerd; Hergarten, Marcus; Kozupa, Marian; Majchrzak, Maria
2006-04-28
Gas chromatography with simultaneous flame-ionization detection (FID) and a nitrogen-phosphorus detection (NPD) as well as gas chromatography-mass spectrometry (GC/MS) has been used to characterize long-chain primary alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and negative chemical ionization (NCI) mass spectra of trifluoroacetylated derivatives of the identified tert-octadecylamines are presented for the first time. The corrosion inhibiting alkyl amines were applied in a water-steam circuit of energy systems in the power industry. Solid-phase extraction (SPE) with octadecyl bonded silica (C18) sorbents followed by gas chromatography were used for quantification of the investigated tert-octadecylamines in boiler water, superheated steam and condensate samples from the power plant. The estimated values were: 89 microg l(-1)(n = 5, RSD = 7.8%), 45 microg l(-1) (n = 5, RSD = 5.4%) and 37 microg l(-1)(n = 5, RSD = 2.3%), respectively.
NASA Astrophysics Data System (ADS)
Takegami, Shigehiko; Kitamura, Keisuke; Ohsugi, Mayuko; Ito, Aya; Kitade, Tatsuya
2015-06-01
In order to quantitatively examine the lipophilicity of the widely used organophosphorus pesticides (OPs) chlorfenvinphos (CFVP), chlorpyrifos-methyl (CPFM), diazinon (DZN), fenitrothion (FNT), fenthion (FT), isofenphos (IFP), profenofos (PFF) and pyraclofos (PCF), their partition coefficient (Kp) values between phosphatidylcholine (PC) small unilamellar vesicles (SUVs) and water (liposome-water system) were determined by second-derivative spectrophotometry. The second-derivative spectra of these OPs in the presence of PC SUV showed a bathochromic shift according to the increase in PC concentration and distinct derivative isosbestic points, demonstrating the complete elimination of the residual background signal effects that were observed in the absorption spectra. The Kp values were calculated from the second-derivative intensity change induced by addition of PC SUV and obtained with a good precision of R.S.D. below 10%. The Kp values were in the order of CPFM > FT > PFF > PCF > IFP > CFVP > FNT ⩾ DZN and did not show a linear correlation relationship with the reported partition coefficients obtained using an n-octanol-water system (R2 = 0.530). Also, the results quantitatively clarified the effect of chemical-group substitution in OPs on their lipophilicity. Since the partition coefficient for the liposome-water system is more effective for modeling the quantitative structure-activity relationship than that for the n-octanol-water system, the obtained results are toxicologically important for estimating the accumulation of these OPs in human cell membranes.
Bahador, Reza; Mirbolook, Ahmadreza; Arbab, Sara; Derakhshan, Pooya; Gholizadeh, Amirmohammad; Abedi, Sadegh
2016-01-01
Background Reflex sympathetic dystrophy (RSD) syndrome is a multifactorial disorder with clinical features of neurogenic inflammation that causes hypersensitivity to pain or severe allodynia as well as blood flow problems, swelling, skin discoloration and maladaptive neuroplasticity due to vasomotor disorders. Patients with major trauma are prone to homeostasis leading to inflammatory response syndrome and multiple organ distress syndrome. Several studies have investigated the etiology of this condition, but the cause remains unknown. The role of associated factors such as the limb immobilization technique and genetics has been reported in the development of this complication, but, so far, there is no information regarding the effect of trauma severity on the risk of RSD occurrence. Objectives Given the importance of diagnosing and treating this condition, we aimed to study the effect of trauma severity on the prevalence of RSD. Patients and Methods In this cross-sectional study, we examined patients with distal tibial fracture who visited Rasht Poursina hospital from 2010 to 2013. Exclusion criteria included associated fractures, underlying musculoskeletal diseases and mental and cognitive problems. To assess the severity of the initial injury in patients, the Hannover Fracture Scale 98 (HFS98) scoring checklist was used. The diagnosis of RSD was made on the basis of the IASP criterion. Demographic data, HFS98 scores, and information regarding RSD prevalence were analyzed using SPSS version 20. The Mann Whitney U nonparametric test was used for variables that were not normally distributed; the chi-square test was used to compare the qualitative variables. Results Among the 488 patients, 292 (59.83%) were male. The mean age of the study population was 44 ± 9.82 years. During the 6-month follow-up, RSD occurred in 45 patients, of whom 28 (62.22%) were female and 17 (37.77%) were male; there was thus a significant difference in the prevalence of RSD in terms of gender (P = 0.00; chi square test). The mean HFS98 score in patients without and with RSD was 3.081 ± 4.083 and 4.080 ± 4.622, respectively, and the difference was not statistically significant (P = 0.363; Mann Whitney U test). Analyses of the eight items of HFS98 shows that local circulation in patients with RSD is significantly better than that in patients without RDS (0.683 ± 0.822 vs. 0.528 ± 0.629, respectively). Statistical analysis showed that the odds ratio for RSD for patients with HFS95 score > 0 was 1.079 (confidence interval [CI]: 0.898 - 1.333). Moreover, the odds ratio for RSD was 1.100 (CI: 795 - 1.531) in patients with an injury severity score higher than the calculated mean score in patients without RSD (> 4.083). Conclusions The results suggest no significant relationship between the severity of injury and risk of RSD occurrence, although the mean injury severity score was higher in patients with RSD than in those without RSD in this study population. The lower score of local circulation in patients with RSD than in those without RSD is a statistically significant finding and can be attributed to changes in the antioxidant levels at the injury site, which is one of the main mechanisms for the onset of RSD. Wound contamination was also justifiably higher in patients with RSD, although the difference was not statistically significant. In summary, the severity of injury alone cannot be a determining factor for predicting the probability of RSD. PMID:27626009
Bahador, Reza; Mirbolook, Ahmadreza; Arbab, Sara; Derakhshan, Pooya; Gholizadeh, Amirmohammad; Abedi, Sadegh
2016-05-01
Reflex sympathetic dystrophy (RSD) syndrome is a multifactorial disorder with clinical features of neurogenic inflammation that causes hypersensitivity to pain or severe allodynia as well as blood flow problems, swelling, skin discoloration and maladaptive neuroplasticity due to vasomotor disorders. Patients with major trauma are prone to homeostasis leading to inflammatory response syndrome and multiple organ distress syndrome. Several studies have investigated the etiology of this condition, but the cause remains unknown. The role of associated factors such as the limb immobilization technique and genetics has been reported in the development of this complication, but, so far, there is no information regarding the effect of trauma severity on the risk of RSD occurrence. Given the importance of diagnosing and treating this condition, we aimed to study the effect of trauma severity on the prevalence of RSD. In this cross-sectional study, we examined patients with distal tibial fracture who visited Rasht Poursina hospital from 2010 to 2013. Exclusion criteria included associated fractures, underlying musculoskeletal diseases and mental and cognitive problems. To assess the severity of the initial injury in patients, the Hannover Fracture Scale 98 (HFS98) scoring checklist was used. The diagnosis of RSD was made on the basis of the IASP criterion. Demographic data, HFS98 scores, and information regarding RSD prevalence were analyzed using SPSS version 20. The Mann Whitney U nonparametric test was used for variables that were not normally distributed; the chi-square test was used to compare the qualitative variables. Among the 488 patients, 292 (59.83%) were male. The mean age of the study population was 44 ± 9.82 years. During the 6-month follow-up, RSD occurred in 45 patients, of whom 28 (62.22%) were female and 17 (37.77%) were male; there was thus a significant difference in the prevalence of RSD in terms of gender (P = 0.00; chi square test). The mean HFS98 score in patients without and with RSD was 3.081 ± 4.083 and 4.080 ± 4.622, respectively, and the difference was not statistically significant (P = 0.363; Mann Whitney U test). Analyses of the eight items of HFS98 shows that local circulation in patients with RSD is significantly better than that in patients without RDS (0.683 ± 0.822 vs. 0.528 ± 0.629, respectively). Statistical analysis showed that the odds ratio for RSD for patients with HFS95 score > 0 was 1.079 (confidence interval [CI]: 0.898 - 1.333). Moreover, the odds ratio for RSD was 1.100 (CI: 795 - 1.531) in patients with an injury severity score higher than the calculated mean score in patients without RSD (> 4.083). The results suggest no significant relationship between the severity of injury and risk of RSD occurrence, although the mean injury severity score was higher in patients with RSD than in those without RSD in this study population. The lower score of local circulation in patients with RSD than in those without RSD is a statistically significant finding and can be attributed to changes in the antioxidant levels at the injury site, which is one of the main mechanisms for the onset of RSD. Wound contamination was also justifiably higher in patients with RSD, although the difference was not statistically significant. In summary, the severity of injury alone cannot be a determining factor for predicting the probability of RSD.
[Is the suicidal risk assessment scale RSD of predictive value?].
Ducher, J L; Terra, J L
2006-10-01
A part (60% to 70%) of those who are going to act out their suicide consult a doctor the month before. Studies have shown the need to improve the practitioner's capacity to diagnose depression. The assessment of the suicidal risk is crucial. The search for suicidal risk factors helps to define the populations at risk. However, it doesn't provide information concerning the possibility of acting out in the short term. And how does one react when faced with those who do not present any of the risk factors? Psychometric instruments attempt to help the therapist in his/her reasoning. SUICIDAL RISK ASSESSMENT: Among them, the suicidal risk assessment scale RSD should be mentioned. Its objective is to estimate the seriousness of the suicidal risk, with 11 levels. It is built around a possible will to commit suicide rather than a single assessment of the frequency of suicidal ideas. Its construction in hierarchical order permits the progressive assessment of the suicidal risk, in the form of a semi-structured interview. Hence, the suicidal risk assessment scale RSD looks for the existence of death wishes (levels 1-2), of suicide ideations and its frequency (levels 3-4-5), and of a passive desire to die (level 6). Level 7 shows the onset of a decision making process, except that the patient is still inhibited by various important factors in his/her life. More often, the fear of inflicting immense suffering to his/her loved ones or for religious beliefs, is found. From level 8, determination has made way to hesitation. An active death wish exists, and although the plan remains undefined, the act is decided on. At level 9 the methods of application are developed and a plan is established. The ultimate level exists when there is a start in the preparation of the act of suicide (level 10). This hierarchical order has been confirmed by some epidemiological studies. The inclusion of the suicidal risk assessment scale RSD in a double-blind, placebo-controlled study, which tested the efficacy of fluvoxamine in reducing the risk of recurrence of depression over 18 months, appears of particular interest. In this multicentre study, patients of both sexes were included, aged between 18 and 70 years, presenting a major depressive episode with a MADRS equal to a minimum of 25, and having had a minimum of two episodes of major depression within the last five years. The resulting analysis carried out on 103 patients showed a satisfactory concurrent validity between the suicidal risk assessment scale RSD and the items "suicide" of the MADRS (rho=0.79; p=0.0001) and the Hamilton Depression Scale (rho=0.70; p=0.0001), and fairly satisfactory concurrent validity with the depression degree assessed by the MADRS overall score (rho=0.40; p=0.0001). The short-term follow-up under treatment revealed enhanced sensitivity of the RSD versus the MADRS. The improvement in suicidal risk, assessed by the RSD, was faster than the improvement in depression, which is interesting from a clinical point of view. The medium-term follow-up tested the predictive validity of RSD and confirmed a greater level of suicidal risk from a score of 7 on the RSD, with the death by suicide of 2 subjects among the 15 who exhibited a score between 7 and 10 on the RSD on inclusion. On the other hand, no acting out, no attempted suicides, and no suicides were noted in the group of 88 subjects whose RSD was lower or equal to 6 on inclusion (p=0.02 using Fisher's exact test). Thus, the RSD appears of interest, from a clinical point of view, by providing a -diagnostic, or a scientific approach.
NASA Astrophysics Data System (ADS)
Jiang, Cheng-Yong; Sun, Shi-Hao; Zhang, Qi-Dong; Liu, Jun-Hui; Zhang, Jian-Xun; Zong, Yong-Li; Xie, Jian-Ping
2013-03-01
A method with atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) was developed and applied to direct analysis of Environmental Tobacco Smoke (ETS), using 3-ethenylpyridine (3-EP) as a vapour-phase marker. In this study, the ion source of APCI-MS/MS was modified and direct analysis of gas sample was achieved by the modified instrument. ETS samples were directly introduced, via an atmospheric pressure inlet, into the APCI source. Ionization was carried out in positive-ion APCI mode and 3-EP was identified by both full scan mode and daughter scan mode. Quantification of 3-EP was performed by multiple reaction monitoring (MRM) mode. The calibration curve was obtained in the range of 1-250 ng L-1 with a satisfactory regression coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.5 ng L-1 and 1.6 ng L-1, respectively. The precision of the method, calculated as relative standard deviation (RSD), was characterized by repeatability (RSD 3.92%) and reproducibility (RSD 4.81%), respectively. In real-world ETS samples analysis, compared with the conventional GC-MS method, the direct APCI-MS/MS has shown better reliability and practicability in the determination of 3-EP at trace level. The developed method is simple, fast, sensitive and repeatable; furthermore, it could provide an alternative way for the determination of other volatile pollutants in ambient air at low levels.
Wang, Xuemei; Wang, Huan; Huang, Pengfei; Ma, Xiaomin; Lu, Xiaoquan; Du, Xinzhen
2017-01-06
A superior solid-phase microextraction (SPME) fiber-coating material, three dimensional order mesoporous polymers with Ia-3d bicontinuous cubic structure (3D-OMPs) was in situ coated on a stainless steel wire by solvent evaporation induced self-assembly (EISA) and thermo-polymerization. Fourier-transform infrared spectrometry (FTIR), transmission electron microscopy (TEM), scanning electron microscopy (SEM), small-angel X-ray diffraction (SAXRD), N 2 adsorption-desorption transmission, and thermogravimetry analysis (TGA) were applied to the characterization of the synthesized 3D-OMPs coating. The performance and feasibility of the homemade fiber was evaluated through direct immersion (DI) SPME followed by high-performance liquid chromatography-UV detector (HPLC-UV) for the simultaneous extraction of seven chlorophenols in water samples. Under the optimum conditions, the prepared fiber exhibited excellent extraction properties as compared to three commercial fibers, the DI-SPME-HPLC-UV method showed low limits of detection (0.32-1.85μgL -1 ), wide linear ranges (5.0-1000μgL -1 ), and acceptable reproducibility (relative standard deviation, RSD<7.6% for one fiber, RSD<8.9% for fiber to fiber). Moreover, the method was further successfully applied to the analysis of seven CPs in real samples with good recoveries (80.5-99.5%) and satisfactory precisions (RSD<9.2%). It was confirmed that the proposed method has high sensitivity, outstanding selectivity and good reproducibility to the determination of trace CPs in the environmental water. Copyright © 2016 Elsevier B.V. All rights reserved.
Rsd family proteins make simultaneous interactions with regions 2 and 4 of the primary sigma factor
Yuan, Andy H.; Gregory, Brian D.; Sharp, Josh S.; McCleary, Katherine D.; Dove, Simon L.; Hochschild, Ann
2008-01-01
Summary Bacterial anti-σ factors typically regulate σ factor function by restricting the access of their cognate σ factors to the RNA polymerase (RNAP) core enzyme. The E. coli Rsd protein forms a complex with the primary σ factor, σ70, inhibits σ70-dependent transcription in vitro, and has been proposed to function as a σ70-specific anti-σ factor, thereby facilitating the utilization of alternative σ factors. In prior work, Rsd has been shown to interact with conserved region 4 of σ70, but it is not known whether this interaction suffices to account for the regulatory functions of Rsd. Here we show that Rsd and the Rsd ortholog AlgQ, a global regulator of gene expression in P. aeruginosa, interact with conserved region 2 of σ70. We show further that Rsd and AlgQ can interact simultaneously with regions 2 and 4 of σ70. Our findings establish that the abilities of Rsd and AlgQ to interact with σ70 region 2 are important determinants of their in vitro and in vivo activities. PMID:18826409
Rsd family proteins make simultaneous interactions with regions 2 and 4 of the primary sigma factor.
Yuan, Andy H; Gregory, Brian D; Sharp, Josh S; McCleary, Katherine D; Dove, Simon L; Hochschild, Ann
2008-12-01
Bacterial anti-sigma factors typically regulate sigma factor function by restricting the access of their cognate sigma factors to the RNA polymerase (RNAP) core enzyme. The Escherichia coli Rsd protein forms a complex with the primary sigma factor, sigma(70), inhibits sigma(70)-dependent transcription in vitro, and has been proposed to function as a sigma(70)-specific anti-sigma factor, thereby facilitating the utilization of alternative sigma factors. In prior work, Rsd has been shown to interact with conserved region 4 of sigma(70), but it is not known whether this interaction suffices to account for the regulatory functions of Rsd. Here we show that Rsd and the Rsd orthologue AlgQ, a global regulator of gene expression in Pseudomonas aeruginosa, interact with conserved region 2 of sigma(70). We show further that Rsd and AlgQ can interact simultaneously with regions 2 and 4 of sigma(70). Our findings establish that the abilities of Rsd and AlgQ to interact with sigma(70) region 2 are important determinants of their in vitro and in vivo activities.
Zhao, Qingyan; Huang, He; Wang, Xule; Wang, Xiaozhan; Dai, Zixuan; Wan, Peixing; Guo, Zongwen; Yu, Shengbo; Tang, Yanhong; Huang, Congxin
2014-01-01
Neurohormonal activation is a commonly cited array of phenomena in the body's physiologic response to heart failure (HF). The aim of the present study was to determine the change law of serum neurohormones after renal sympathetic denervation (RSD) in dogs with pacing-induced HF. Twenty-eight beagles were randomly divided into control group, RSD group, HF group and HF + RSD group. The control group was implanted pacemakers without pacing; the RSD group underwent renal artery ablation without pacing; the HF group was implanted pacemakers with ventricular pacing at 240 bpm for 3 weeks; and HF + RSD group underwent renal artery ablation and with ventricular pacing at 240 bpm for 3 weeks. Blood samples were taken at baseline, and 3, 6, 9, 12, 15, 18, 21 days in all the dogs for neurohormones measurement. After 3 weeks, the systolic femoral artery pressures in the HF and HF + RSD groups were reduced after pacing 3 weeks. There was an increase significantly in BNP, angiotensin II, aldosterone, endothelin-1 and decrease in renalase after 3 weeks when compared with baseline in HF group. RSD significantly suppressed the changes of plasma neurohormones concentration in experimental HF, but RSD had not obviously impact on the levels of plasma neurohormones during 3 weeks in RSD group. RSD attenuates the changes of levels of plasma neurohormones in the activated renin-angiotensin-aldosterone system (RAAS) but had not obviously effect in the normal physiology of RAAS.
Chen, Pingan; Leng, Shuilong; Luo, Yishan; Li, Shaonan; Huang, Zicheng; Liu, Zhenxi; Liu, Zhen; Wang, Jie; Lei, Xiaoming
2017-02-01
In dogs with heart failure (HF) induced by overload pressure, the role of renal sympathetic denervation (RSD) on heart failure and in the renal artery is unclear. Therefore, we investigated the efficacy and safety of RSD in dogs with pressure overload-induced heart failure. Twenty mongrel dogs were divided into a sham-operated group, an HF group and an HF + RSD group. In the sham-operated group, the abdominal aorta was located but was not constricted, in the HF group, the abdominal aorta was constricted without RSD, and the HF+RSD group underwent RSD with constriction of the abdominal aorta after 10 weeks. Blood sampling assays, echocardiography, intravascular ultrasound (IVUS) measurement and histopathological examination were performed. Renal sympathetic denervation caused a significant reduction in the levels of noradrenaline (166.62±6.84 vs. 183.48±13.66 pg/ml, P<0.05), plasma renin activity (1.93±0.12 vs. 2.10±0.13 ng/mlh, P<0.05) and B-type natriuretic peptide (71.14±3.86 vs. 83.15±5.73 pg/ml, P<0.05) at eight weeks after RSD in the HF+RSD group. Compared with the HF group at eight weeks, the left ventricular internal dimension at end-diastole and end-systole were lower and the left ventricular ejection fraction was higher (all P<0.05) at eight weeks after RSD in the HF+RSD group. Intravenous ultrasound images showed no changes in the renal artery lumen, and intimal hyperplasia and vascular lumen stenosis were not observed after RSD. Renal sympathetic denervation could improve cardiac function in dogs with HF induced by pressure overload; RSD had no adverse influence on the renal artery. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Brown, Paula N.; Chan, Michael; Paley, Lori; Betz, Joseph M.
2013-01-01
A method previously validated to determine caftaric acid, chlorogenic acid, cynarin, echinacoside, and cichoric acid in echinacea raw materials has been successfully applied to dry extract and liquid tincture products in response to North American consumer needs. Single-laboratory validation was used to assess the repeatability, accuracy, selectivity, LOD, LOQ, analyte stability (ruggedness), and linearity of the method, with emphasis on finished products. Repeatability precision for each phenolic compound was between 1.04 and 5.65% RSD, with HorRat values between 0.30 and 1.39 for raw and dry extract finished products. HorRat values for tinctures were between 0.09 and 1.10. Accuracy of the method was determined through spike recovery studies. Recovery of each compound from raw material negative control (ginseng) was between 90 and 114%, while recovery from the finished product negative control (maltodextrin and magnesium stearate) was between 97 and 103%. A study was conducted to determine if cichoric acid, a major phenolic component of Echinacea purpurea (L.) Moench and E. angustifolia DC, degrades during sample preparation (extraction) and HPLC analysis. No significant degradation was observed over an extended testing period using the validated method. PMID:22165004
Brown, Paula N; Chan, Michael; Paley, Lori; Betz, Joseph M
2011-01-01
A method previously validated to determine caftaric acid, chlorogenic acid, cynarin, echinacoside, and cichoric acid in echinacea raw materials has been successfully applied to dry extract and liquid tincture products in response to North American consumer needs. Single-laboratory validation was used to assess the repeatability, accuracy, selectivity, LOD, LOQ, analyte stability (ruggedness), and linearity of the method, with emphasis on finished products. Repeatability precision for each phenolic compound was between 1.04 and 5.65% RSD, with HorRat values between 0.30 and 1.39 for raw and dry extract finished products. HorRat values for tinctures were between 0.09 and 1.10. Accuracy of the method was determined through spike recovery studies. Recovery of each compound from raw material negative control (ginseng) was between 90 and 114%, while recovery from the finished product negative control (maltodextrin and magnesium stearate) was between 97 and 103%. A study was conducted to determine if cichoric acid, a major phenolic component of Echinacea purpurea (L.) Moench and E. angustifolia DC, degrades during sample preparation (extraction) and HPLC analysis. No significant degradation was observed over an extended testing period using the validated method.
de Gois, Jefferson S; Vallelonga, Paul; Spolaor, Andrea; Devulder, Veerle; Borges, Daniel L G; Vanhaecke, Frank
2016-01-01
A simple and accurate methodology for Br isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with pneumatic nebulization for sample introduction was developed. The Br(+) signals could be measured interference-free at high mass resolution. Memory effects for Br were counteracted using 5 mmol L(-1) of NH4OH in sample, standard, and wash solutions. The major cation load of seawater was removed via cation exchange chromatography using Dowex 50WX8 resin. Subsequent Br preconcentration was accomplished via evaporation of the sample solution at 90 °C, which did not induce Br losses or isotope fractionation. Mass discrimination was corrected for by external correction using a Cl-matched standard measured in a sample-standard bracketing approach, although Sr, Ge, and Se were also tested as potential internal standards for internal correction for mass discrimination. The δ(81)Br (versus standard mean ocean bromide (SMOB)) values thus obtained for the NaBr isotopic reference material NIST SRM 977 and for IRMM BCR-403 seawater certified reference material are in agreement with literature values. For NIST SRM 977, the (81)Br/(79)Br ratio (0.97291) was determined with a precision ≤0.08‰ relative standard deviation (RSD).
NASA Astrophysics Data System (ADS)
Dhara, Sangita; Khooha, Ajay; Singh, Ajit Kumar; Tiwari, M. K.; Misra, N. L.
2018-06-01
Systematic studies to assess the analytical parameters obtained in the total reflection X-ray fluorescence (TXRF) determinations of interfering elements Rb and U using profile fitting are reported in the present manuscript. The X-ray lines Rb Kα and U Lα having serious spectral interference (ΔE = 218 eV), have been used as analytical lines. The intensities of these X-ray lines have been assessed using profile fitting. In order to compare the analytical results of Rb determinations in presence of U, with and without U excitation, synchrotron radiation was tuned to energy just above and below the U Labs edge. This approach shall excite both Rb Kα and U Lα simultaneously and Rb Kα selectively. Finally, the samples were also analyzed with a laboratory based TXRF spectrometer. The analytical results obtained in all these conditions were comparable. The authenticity of the results was assessed by analyzing U with respect to Rb in Rb2U(SO4)3, a standard reference material for U. The average precision obtained for TXRF determinations was below 3% (RSD, n = 3, 1σ) and the percent deviation of TXRF values from the expected values calculated on the basis of sample preparation was within 3%.
Toyota, Akie; Akiyama, Hiroshi; Sugimura, Mitsunori; Watanabe, Takahiro; Kikuchi, Hiroyuki; Kanamori, Hisayuki; Hino, Akihiro; Esaka, Muneharu; Maitani, Tamio
2006-04-01
Because the labeling of grains and feed- and foodstuffs is mandatory if the genetically modified organism (GMO) content exceeds a certain level of approved genetically modified varieties in many countries, there is a need for a rapid and useful method of GMO quantification in food samples. In this study, a rapid detection system was developed for Roundup Ready Soybean (RRS) quantification using a combination of a capillary-type real-time PCR system, a LightCycler real-time PCR system, and plasmid DNA as the reference standard. In addition, we showed for the first time that the plasmid and genomic DNA should be similar in the established detection system because the PCR efficiencies of using plasmid DNA and using genomic DNA were not significantly different. The conversion factor (Cf) to calculate RRS content (%) was further determined from the average value analyzed in three laboratories. The accuracy and reproducibility of this system for RRS quantification at a level of 5.0% were within a range from 4.46 to 5.07% for RRS content and within a range from 2.0% to 7.0% for the relative standard deviation (RSD) value, respectively. This system rapidly monitored the labeling system and had allowable levels of accuracy and precision.
Jones-Lepp, Tammy L.; Taniguchi-Fu, Randi L.; Morgan, Jade; Nance Jr., Trevor; Ward, Matthew; Alvarez, David A.; Mills, Lesley
2015-01-01
The emphasis of this research project was to develop and optimize a solid-phase extraction method and highperformance liquid chromatography-electrospray ionizationmass spectrometry method, such that a linkage between the detection of endocrine-active pharmaceuticals (EAPs) in the aquatic environment and subsequent effects on fish populations could eventually be studied. Four EAPs were studied: tamoxifen (TAM), exemestane (EXE), letrozole (LET), anastrozole (ANA); and three TAM metabolites: 4- hydroxytamoxifen, e/z endoxifen, and n-desmethyl tamoxifen. In aqueous matrices, the use of isotopically labeled standards for the EAPs allowed for the generation of good recoveries, greater than 80 %, and low relative standard deviations (% RSDs) (3 to 27 %). TAM metabolites had lower recoveries in the spiked water matrices: 35 to 93 % in waste/source water compared to 58 to 110 % in DI water. The precision in DI water was acceptable ranging from 8 to 38 % RSD. However, the precision in real environmental wastewaters could be poor, ranging from 15 to 120 % RSD, dependent upon unique matrix effects. In plasma, the overall recoveries of the EAPs were acceptable: 88 to 110 %, with %RSDs of 6 to 18 % (Table 3). The spiked recoveries of the TAM metabolites from plasma were good, ranging from 77 to 120 %, with %RSDs ranging from 27 to 32 %. Two of the TAM metabolites, 4- hydroxytamoxifen and n-desmethyl tamoxifen, were confirmed in most of the environmental aqueous samples. The discovery of TAM metabolites demonstrates that the source of the TAM metabolites, TAM, is constant, introducing a pseudo-persistence of this chemical into the environment.
Spectrophotometric determination of flucloxacillin and dicloxacillin in pure and dosage forms.
El-Dien, F A Nour; Mohamed, Gehad G; Farag, Eman Y Z A
2006-05-01
A simple, rapid and accurate spectrophotometric method for the determination of antibiotic drugs, flucloxacillin (Fluclox) and dicloxacillin (Diclox), in pure form and different pharmaceutical preparations has been developed. The charge transfer (CT) reactions between Fluclox and Diclox as electron donors and 7,7,8,8-tetracyanoquinodimethane (TCNQ) and tetracyanoethylene (TCNE) as pi-acceptors to give highly coloured complex species have been spectrophotometrically studied. The optimum experimental conditions for these CT reactions have been studied carefully. Beer's law is obeyed over the concentration ranges of 4-180 microg mL(-1) and 4-70 microg mL(-1) for Fluclox and Diclox drugs using TCNQ and TCNE reagents, respectively. The Sandell sensitivities (S) are found to be 0.016-0.035 microg cm(-2) and 0.011-0.016 microg cm(-2) for Fluclox and Diclox, respectively, which indicate the high sensitivity of the proposed method. The relative standard deviations (R.S.D.: 0.08-0.49 and 0.15-0.80) for the determination of Fluclox and (R.S.D.: 0.05-0.75 and 0.13-0.75) for Diclox were obtained for four to six replicates using TCNQ and TCNE reagents, respectively, refer to the high accuracy and precision of the proposed method. These results are also confirmed by the between-day precision and the percent recovery of 99.90-100.1 and 99.60-100.4 for Fluclox and 99.90-100.5 and 99.40-100.1 for Diclox using TNCQ and TCNE reagents, respectively. The results obtained for the two reagents are comparable with those obtained by the official method.
Assessment of visual distortions in age-related macular degeneration: emergence of new approaches
Vazquez, Noelia Pitrelli; Knox, Paul C.
2016-01-01
Aims With the arrival of effective treatments for neovascular age-related macular degeneration (nvAMD) there is a need to find improved tests that would allow early detection. Ideally, these tests would allow monitoring of vision by patients themselves from home. The aim of this review is to discuss the available evidence for two recently developed vision tests designed for this purpose: the Preferential Hyperacuity Perimeter (PHP) test and the Radial Shape Discrimination (RSD) test. Methods Articles that investigated detection of nvAMD were reviewed. The methodology of the clinical evidence, where available, was judged for bias and applicability of the results to the general population using the QUADAS-2 quality assessment tool. Results The PHP test has proved to be good at detecting nvAMD but many studies assessed in this review were biased in the selection of patients, restricting the results to only those patients who can use the test and produce reliable results. On the other hand the RSD test is a simple test, well accepted by elderly patients with AMD. However, clinical studies to determine its value in the detection of early signs of nvAMD are still required. Conclusions To date, more studies have investigated the utility of the PHP test compared with the RSD test for detection of nvAMD. Both tests show promise but further evidence is needed to determine the real generalisability of the PHP test and the sensitivity of the RSD test. PMID:27738450
Giannetti, L; Longo, F; Buiarelli, F; Russo, M V; Neri, B
2010-09-01
A specific, sensitive and robust liquid chromatography tandem mass spectrometry method for determining oxytetracycline, tetracycline, chlortetracycline and doxycycline in royal jelly and honey samples is presented. Extraction of drug residues was performed by ammonium acetate buffer as extractant followed by a clean-up with metal chelate affinity chromatography and solid-phase extraction. Tetracycline analysis was performed using liquid chromatography-electrospray ionisation-tandem mass spectrometry. The presented method is the first validated for royal jelly and in accordance with the requirements set by Commission Decision 2002/657/EC. Recoveries of the methods, calculated spiking the samples at 5.0, 10.0, 20.0 and 30.0 μg kg(-1), were 79% to 90% for honey and 77% to 90% for royal jelly. The intra-day precision (RSD) ranged between 8.1% and 15.0% for honey and from 9.1% to 16.3% for royal jelly, while inter-day precision values were from 10.2% to 17.6% and from 10.6% to 18.4% respectively for honey and royal jelly. Linearity for the four analytes was calculated from 5.0 to 50.0 μg kg(-1). The decision limits (CCα) ranged from 6.2 to 6.4 μg kg(-1) and from 6.1 to 6.5 μg kg(-1) for honey and royal jelly, respectively. Detection capabilities values (CCβ) ranged between 7.2 and 7.7 μg kg(-1) and from 7.3 to 7.9 μg kg(-1) respectively for honey and royal jelly. The developed method is currently in use for confirmation of the official control analysis of honey and royal jelly samples.
Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang
2014-11-01
In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of some phenolic compounds in red wine by RP-HPLC: method development and validation.
Burin, Vívian Maria; Arcari, Stefany Grützmann; Costa, Léa Luzia Freitas; Bordignon-Luiz, Marilde T
2011-09-01
A methodology employing reversed-phase high-performance liquid chromatography (RP-HPLC) was developed and validated for simultaneous determination of five phenolic compounds in red wine. The chromatographic separation was carried out in a C(18) column with water acidify with acetic acid (pH 2.6) (solvent A) and 20% solvent A and 80% acetonitrile (solvent B) as the mobile phase. The validation parameters included: selectivity, linearity, range, limits of detection and quantitation, precision and accuracy, using an internal standard. All calibration curves were linear (R(2) > 0.999) within the range, and good precision (RSD < 2.6%) and recovery (80-120%) was obtained for all compounds. This method was applied to quantify phenolics in red wine samples from Santa Catarina State, Brazil, and good separation peaks for phenolic compounds in these wines were observed.
A global view of Escherichia coli Rsd protein and its interactions.
Piper, Sarah E; Mitchell, Jennie E; Lee, David J; Busby, Stephen J W
2009-12-01
The Escherichia coli Rsd protein forms 1 : 1 complexes with sigma(70) protein, which is the major factor in determining promoter recognition by RNA polymerase. Here we describe measurements of the levels of Rsd, RNA polymerase, sigma(70) and the alternative sigma(38) factor. Rsd levels are sufficient to sequester a significant proportion of sigma(70) and immunoaffinity pull-down experiments show that this occurs in stationary phase but not in exponentially growing cells. Rsd expression is controlled by two promoters, P1 and P2. Experiments with lac fusions show that the P2 promoter is stronger than P1, that P2 is active in all phases of growth, and that this accounts for the high levels of Rsd.
Mano, Junichi; Masubuchi, Tomoko; Hatano, Shuko; Futo, Satoshi; Koiwa, Tomohiro; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Takabatake, Reona; Kitta, Kazumi
2013-01-01
In this article, we report a novel real-time PCR-based analytical method for quantitation of the GM maize event LY038. We designed LY038-specific and maize endogenous reference DNA-specific PCR amplifications. After confirming the specificity and linearity of the LY038-specific PCR amplification, we determined the conversion factor required to calculate the weight-based content of GM organism (GMO) in a multilaboratory evaluation. Finally, in order to validate the developed method, an interlaboratory collaborative trial according to the internationally harmonized guidelines was performed with blind DNA samples containing LY038 at the mixing levels of 0, 0.5, 1.0, 5.0 and 10.0%. The precision of the method was evaluated as the RSD of reproducibility (RSDR), and the values obtained were all less than 25%. The limit of quantitation of the method was judged to be 0.5% based on the definition of ISO 24276 guideline. The results from the collaborative trial suggested that the developed quantitative method would be suitable for practical testing of LY038 maize.
Devos, Christophe; David, Frank; Sandra, Pat
2012-10-26
According to recent directives of the European Union (EU), limits of quantification (LOQ) for the determination of tributyltin (TBT) in surface waters should be ca. 60 pg/L (ppq). This put very stringent requirements on analytical methodologies; definitely when they have to be applied in a routine environment. Stir bar sorptive extraction (SBSE), followed by thermal desorption (TD) and capillary gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) can provide accurate and precise data at the 2 ng/L level (ppt). For lower concentrations, matrix and reagent interferences together with contamination may provide too high TBT values. A two-dimensional heart-cut GC method was developed to fractionate TBT from interferences. The GC-GC-MS/MS method shows excellent linearity in the range 50 pg/L-4 ng/L, good repeatability (RSD<20% at 200 pg/L), and a limit of detection of 11 pg/L. The method performance is demonstrated with representative samples i.e. harbor water and waste water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Banana peel as an adsorbent for removing atrazine and ametryne from waters.
Silva, Claudineia R; Gomes, Taciana F; Andrade, Graziela C R M; Monteiro, Sergio H; Dias, Ana C R; Zagatto, Elias A G; Tornisielo, Valdemar L
2013-03-13
The feasibility of using banana peel for removal of the pesticides atrazine and ametryne from river and treated waters has been demonstrated, allowing the design of an efficient, fast, and low-cost strategy for remediation of polluted waters. The conditions for removal of these pesticides in a laboratory scale were optimized as sample volume = 50 mL, banana mass = 3.0 g, stirring time = 40 min, and no pH adjustment necessary. KF(sor) values for atrazine and ametryne were evaluated as 35.8 and 54.1 μg g(-1) (μL mL(-1)) by using liquid scintillation spectrometry. Adsorption was also evaluated by LC-ESI-MS/MS. As quantification limits were 0.10 and 0.14 μg L(-1) for both pesticides, sample preconcentration was not needed. Linear analytical curves (up to 10 μg L(-1)), precise results (RSD < 4.5%), good recoveries (82.9-106.6%), and a > 90% removal efficiency were attained for both pesticides. Water samples collected near an intensively cultivated area were adequately remedied.
[Determination of terpene lactones in Ginkgo biloba leaves in different ages by UPLC-TQ-MS].
Yao, Xin; Zhou, Gui-Sheng; Tang, Yu-Ping; Qian, Ye-Fei; Shang, Er-Xin; Su, Shu-Lan; Qian, Da-Wei; Duan, Jin-Ao
2013-02-01
To establish an ultra-high performance liquid chromatography coupled with triple quadrupole mass (UPLC-TQ-MS) for determination of four terpene lactones. Chromatographic separation was carried out on a ACQUITY UPLC BEH C18 column (2.1 mm x 100 mm, 1.7 microm) with isocratic elution of 70% methanol at a flow rate of 0.4 mL x min(-1), the column temperature was set at 30 degrees C; Waters Xevo TQ worked in multiple reaction monitoring mode. All calibration curves were linear (r > 0.990 3) over the tested ranges. The average recoveries ranged from 98.83% to 103.9% with RSD value below 3.0%. The contents of total terpene lactones in Ginkgo biloba leaves were significantly different in different ages. The contents in the leaves of young ginkgo tree were higher than that in old tree. The method was simple and fast with high precision, sensitivity and repeatability, which can be used for qualitative and quantitative analysis of terpene lactones in G. biloba leaves.
Zheng, Chengbin; Sturgeon, Ralph E; Brophy, Christine S; He, Shaopan; Hou, Xiandeng
2010-04-01
A novel approach to the generation of volatile iron compounds (likely the pentacarbonyl) with high efficiency is described, wherein solutions containing either Fe(2+) or Fe(3+) and low molecular weight organic acids such as formic, acetic or propionic are exposed to a UV source. An optimum generation efficiency of 60 +/- 2% was achieved in 50% formic acid at pH 2.5 with an irradiation time of 250 s by use of a 17 W low-pressure mercury grid lamp. Compared to conventional solution nebulization, sensitivity and limit of detection were improved 80- and 100-fold, respectively, at the 238.204 nm Fe II emission line. A precision of 0.75% RSD was achieved at a concentration of 100 ng/mL. Photochemical vapor generation sample introduction was used for the determination of trace iron in several environmental Certified Reference Materials, including National Research Council Canada DORM-3 fish muscle tissue, DOLT-3 and DOLT-4 fish liver tissues, and SLRS-5 river water, providing analytical results in excellent agreement with certified values based on a simple external calibration.
De Campeneere, S; Fiems, L O; Van de Voorde, G; Vanacker, J M; Boucque, C V; Demeyer, D I
1999-01-01
Characteristics from the 8th rib cut: chemical composition, tissue composition after dissection, specific gravity (SG) and m. longissimus thoracis (LT) composition, collected on 17 Belgian Blue double-muscled fattening bulls were used to generate equations for predicting chemical carcass composition. Carcass composition was best predicted from chemical analysis of the 8th rib cut and the empty body weight (EBW) of the bull. Carcass chemical fat content (CCF, kg) was predicted from the 8th rib cut fat content (ether extract, 8RF, kg) by the following regression: CCF=1.94+27.37 8RF (R(2)=0.957, RSD =9.89%). A higher coefficient was found for carcass water (CCW, kg) predicted from 8RF and EBW: CCW=-2.26+0.28 EBW-34.28 8RF (R(2)=0.997, RSD=1.48%). No parameter was found to improve the prediction of CCP from EBW solely: CCP=-0.86+0.08 EBW (R(2) =0.992, RSD=2.61%). Prediction equations based solely on LT composition had low R(2) values of between 0.38 and 0.67, whereas no significant equations were found using SG. However, equations based on EBW had R(2) values between 0.78 and 0.99. Chemical components of the 8th rib cut in combination with EBW are most useful in predicting the chemical composition of the carcass of Belgian-Blue double-muscled bulls.
Digital movie-based on automatic titrations.
Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C
2016-01-15
This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.
Vocational rehabilitation considerations for people with reflex sympathetic dystrophy.
Smith, T S; Genoff, M C
1997-01-01
Reflex sympathetic dystrophy (RSD) is identified by the existence of pain, trophic changes, vasomotor instability, limited range of motion and swelling of an extremity. RSD is difficult to treat and prognosis is often poor. Although widely noted in the medical literature, the vocational rehabilitation literature has failed to address the potential role of vocational rehabilitation professionals in the social and economic employment outcome for people with RSD. Vocational rehabilitation professionals are defined as those performing vocational assessments, assessing transferable skills, determining adaptive skills, certifying residual work-related capacities, conducting vocational interest testing, coordinating efforts with pre-injury employers to assist in work reentry efforts, or performing other activities to assist in the placement or retraining of individuals with RSD. The sources used for this article include a review of the literature and observations of the authors. A vocational rehabilitation primer is provided. The following topics are addressed: the anatomical and physiological basis of RSD, treatment protocols, difficulties in accurately diagnosing RSD, influence of litigation, job placement considerations and vocational planning. As the vocational rehabilitation counsellor faces a greater number of people either diagnosed with RSD, or exhibiting RSD symptoms, he/she will be challenged to: (1) increase one's knowledge base about the etiology and treatment of RSD; (2) coordinate personal efforts with other professionals; and (3) provide personal counselling to address lifestyle and motivational factors.
Naik, Vanaja Krishna; Balasundaram, Aruna; Appukuttan, Devapriya; Nainar, Deepavalli Arumuga; Milward, Michael Robert; Victor, Dhayanand John; Junaid, Mohammed
2018-01-01
The aim of this study was to evaluate and compare preprocedural dental anxiety levels and postprocedural pain perception in chronic periodontitis patients during conventional-staged root surface debridement (RSD) and single-stage RSD. Thirty-seven adult generalized chronic periodontitis patients requiring RSD were recruited in this study. Preprocedural anxiety levels were assessed using a self-reported questionnaire and postprocedural pain perceptions were assessed using 0-10 cm visual analog scale. The subject population was divided into two groups: staged RSD ( n = 18) and single-stage RSD ( n = 19). Staged RSD patients visited four times as opposed to single-stage RSD patients. Data were subjected to Pearson Chi-square test, Mann-Whitney U-test, and Spearman's rank correlation. There was no statistically significant difference in dental anxiety levels or pain perceptions in both the groups. Within Group 1, there was statistical significant difference in dental anxiety levels between visit 4 and visit 3 ( P = 0.037) and pain perception between visit 3 and visit 1 ( P = 0.005), visit 4 and visit 1 ( P = 0.002), and visit 4 and visit 2 (0.04) was statistically significant. There was a positive correlation of anxiety questionnaire (Q1-Q4) to the pain score in Group 1 which was statistically significant and in single-stage RSD. Conventional quadrant-wise RSD tends to cognitively condition the anxiety experience thus influencing pain experience.
Zhao, Shuang; Dawe, Margot; Guo, Kevin; Li, Liang
2017-06-20
Metabolites containing a carbonyl group represent several important classes of molecules including various forms of ketones and aldehydes such as steroids and sugars. We report a high-performance chemical isotope labeling (CIL) LC-MS method for profiling the carbonyl submetabolome with high coverage and high accuracy and precision of relative quantification. This method is based on the use of dansylhydrazine (DnsHz) labeling of carbonyl metabolites to change their chemical and physical properties to such an extent that the labeled metabolites can be efficiently separated by reversed phase LC and ionized by electrospray ionization MS. In the analysis of six standards representing different carbonyl classes, acetaldehyde could be ionized only after labeling and MS signals were significantly increased for other 5 standards with an enhancement factor ranging from ∼15-fold for androsterone to ∼940-fold for 2-butanone. Differential 12 C- and 13 C-DnsHz labeling was developed for quantifying metabolic differences in comparative samples where individual samples were separately labeled with 12 C-labeling and spiked with a 13 C-labeled pooled sample, followed by LC-MS analysis, peak pair picking, and peak intensity ratio measurement. In the replicate analysis of a 1:1 12 C-/ 13 C-labeled human urine mixture (n = 6), an average of 2030 ± 39 pairs per run were detected with 1737 pairs in common, indicating the possibility of detecting a large number of carbonyl metabolites as well as high reproducibility of peak pair detection. The average RSD of the peak pair ratios was 7.6%, and 95.6% of the pairs had a RSD value of less than 20%, demonstrating high precision for peak ratio measurement. In addition, the ratios of most peak pairs were close to the expected value of 1.0 (e.g., 95.5% of them had ratios of between 0.67 and 1.5), showing the high accuracy of the method. For metabolite identification, a library of DnsHz-labeled standards was constructed, including 78 carbonyl metabolites with each containing MS, retention time (RT), and MS/MS information. This library and an online search program for labeled carbonyl metabolite identification based on MS, RT, and MS/MS matches have been implemented in a freely available Website, www.mycompoundid.org . Using this library, out of the 1737 peak pairs detected in urine, 33 metabolites were positively identified. In addition, 1333 peak pairs could be matched to the metabolome databases with most of them belonging to the carbonyl metabolites. These results show that 12 C-/ 13 C-DnsHz labeling LC-MS is a useful tool for profiling the carbonyl submetabolome of complex samples with high coverage.
McKim, Daniel B; Patterson, Jenna M; Wohleb, Eric S; Jarrett, Brant L; Reader, Brenda F; Godbout, Jonathan P; Sheridan, John F
2016-05-15
Neuroinflammatory signaling may contribute to the pathophysiology of chronic anxiety disorders. Previous work showed that repeated social defeat (RSD) in mice promoted stress-sensitization that was characterized by the recurrence of anxiety following subthreshold stress 24 days after RSD. Furthermore, splenectomy following RSD prevented the recurrence of anxiety in stress-sensitized mice. We hypothesize that the spleen of RSD-exposed mice became a reservoir of primed monocytes that were released following neuroendocrine activation by subthreshold stress. Mice were subjected to subthreshold stress (i.e., single cycle of social defeat) 24 days after RSD, and immune and behavioral measures were taken. Subthreshold stress 24 days after RSD re-established anxiety-like behavior that was associated with egress of Ly6C(hi) monocytes from the spleen. Moreover, splenectomy before RSD blocked monocyte trafficking to the brain and prevented anxiety-like behavior following subthreshold stress. Splenectomy, however, had no effect on monocyte accumulation or anxiety when determined 14 hours after RSD. In addition, splenocytes cultured 24 days after RSD exhibited a primed inflammatory phenotype. Peripheral sympathetic inhibition before subthreshold stress blocked monocyte trafficking from the spleen to the brain and prevented the re-establishment of anxiety in RSD-sensitized mice. Last, β-adrenergic antagonism also prevented splenic monocyte egress after acute stress. The spleen served as a unique reservoir of primed monocytes that were readily released following sympathetic activation by subthreshold stress that promoted the re-establishment of anxiety. Collectively, the long-term storage of primed monocytes in the spleen may have a profound influence on recurring anxiety disorders. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Huang, Xinqi; Liu, Liangliang; Wen, Teng; Zhu, Rui; Zhang, Jinbo; Cai, Zucong
2015-12-01
Although reductive soil disinfestation (RSD) is increasingly used for the control of soil-borne diseases, its impact on the soil microbial community during and after RSD remains poorly understood. MiSeq pyrosequencing, real-time PCR and denaturing gradient gel electrophoresis were performed to investigate the changes of microbial community in the Fusarium oxysporum f. sp. cubense (FOC) infected soil during RSD and at the simulative banana cultivation after RSD. The results showed that RSD significantly increased soil microbial populations and a different microbial community with the pathogenic soil was established after RSD. Specifically, the number of Firmicutes mainly containing Ruminococcus and Coprococcus followed by a small part of Clostridium which were the dominant bacterial genera significantly increased during RSD. In contrast, Symbiobacterium and Flavisolibacter were the dominant genera in the flooding soil. When the soils were recovered under aerobic condition, the relative abundances of the bacteria belonging to the phylum Bacteroidetes, Acidobacteria, Planctomycetes increased as alternatives to the reducing Firmicutes. For fungi, the population of F. oxysporum significantly decreased during RSD accompanied with the pH decline, which resulted in the significant decrease of relative abundance in the phylum Ascomycota. Alternatively, the relative abundances of some other fungal species increased, such as Chaetomium spp. and Penicillium spp. belonging to Ascomycota and the family Clavulinaceae belonging to Basidiomycota. Then, the relative abundance of Ascomycota re-increased after RSD with Podospora and Zopfiella as dominant genera, whereas the relative abundance of Fusarium further decreased. Overall, the microbial populations and community re-established by RSD made the soil more disease-suppressive and beneficial to the soil nutrient cycling and plant growth compared with the previous pathogenic soil. Copyright © 2015 Elsevier GmbH. All rights reserved.
Wang, Xiaozhan; Zhao, Qingyan; Deng, Hongping; Wang, Xule; Guo, Zongwen; Dai, Zixuan; Xiao, Jinping; Wan, Peixing; Huang, Congxin
2014-10-01
Heart failure (HF) and atrial fibrillation (AF) are associated with sympathetic activation. Renal sympathetic denervation (RSD) can suppress AF vulnerability. The impact of RSD on atrial electrophysiology in experimental HF is unclear. Twenty-two beagles were randomized into control, HF, and HF + RSD groups. Control dogs were implanted cardiac pacemakers without pacing. Dogs in the HF group underwent right ventricular pacing for 3 weeks at 240 beats/min to induce HF. The dogs in the HF + RSD group received RSD and underwent the same HF-inducing procedure. The P-wave dispersion was higher in HF dogs than in the control and HF + RSD dogs (19 ± 3.1 ms vs 13 ± 2.3 ms, 15 ± 2.9 ms, P = 0.04). Conduction time within the interatrium was significantly longer in the HF dogs than that in the control and HF + RSD dogs (39 ± 4 ms vs 31 ± 3 ms, 33 ± 4 ms; P = 0.03). Window of vulnerability (WOV) of AF was widened in the HF dogs than in the HF + RSD dogs (37 ± 5 ms vs 14 ± 3 ms; P < 0.01), while AF could not be induced (WOV = 0) in the control dogs during S1 S2 stimulation. The voltage in the threshold for AF inducibility was lower during ganglionated plexi stimulation in the HF dogs than in the control and HF + RSD dogs (1.8 ± 0.6 V vs 2.5 ± 0.6 V, 2.4 ± 0.4 V; P = 0.04). RSD could reverse the atrial electrical remodeling and decrease AF inducibility in dogs with pacing-induced HF. ©2014 Wiley Periodicals, Inc.
Sympathetic Release of Splenic Monocytes Promotes Recurring Anxiety Following Repeated Social Defeat
McKim, Daniel B.; Patterson, Jenna M.; Wohleb, Eric S.; Jarrett, Brant; Reader, Brenda; Godbout, Jonathan P.; Sheridan, John F.
2015-01-01
Background Neuroinflammatory signaling may contribute to the pathophysiology of chronic anxiety disorders. Previous work showed that repeated social defeat (RSD) in mice promoted stress-sensitization that was characterized by the recurrence of anxiety following sub-threshold stress 24 days after RSD. Furthermore, splenectomy following RSD prevented the recurrence of anxiety in stress-sensitized (SS) mice. We hypothesize that the spleen of RSD-exposed mice became a reservoir of primed monocytes that were released following neuroendocrine activation by sub-threshold stress. Methods Mice were subjected to sub-threshold stress (i.e., single cycle of social defeat) 24 days after RSD, and immune and behavioral measures were taken. Results Sub-threshold stress 24 days after RSD re-established anxiety-like behavior that was associated with egress of Ly6Chi monocytes from the spleen. Moreover, splenectomy prior to RSD blocked monocyte trafficking to the brain and prevented anxiety-like behavior following sub-threshold stress. Splenectomy, however, had no effect on monocyte accumulation or anxiety when determined 14 hours after RSD. In addition, splenocytes cultured 24 days after RSD exhibited a primed inflammatory phenotype. Peripheral sympathetic inhibition prior to sub-threshold stress blocked monocyte trafficking from the spleen to the brain and prevented the re-establishment of anxiety in RSD-sensitized mice. Last, β-adrenergic antagonism also prevented splenic monocyte egress after acute stress. Conclusion The spleen served as a unique reservoir of primed monocytes that were readily released following sympathetic activation by sub-threshold stress that promoted the re-establishment of anxiety. Collectively, the long-term storage of primed monocytes in the spleen may have a profound influence on recurring anxiety disorders. PMID:26281717
Chen, Jue; Cao, Jun; Gao, Wen; Qi, Lian-Wen; Li, Ping
2013-10-21
Ionic liquids (ILs) have numerous chemical applications as environmentally green solvents that are extending into microemulsion applications. In this work, a novel benign IL-in-water microemulsion system modified by an IL surfactant has been proposed for simultaneous extraction of hydrophilic and lipophilic constituents from Flos Chrysanthemi (Chrysanthemum morifolium). Constituents were analyzed by rapid-resolution liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. A mixture-design approach was used to optimize the IL surfactant and the IL oil phase in the microemulsion system. Microemulsions consisting of 6.0% 1-dodecyl-3-methylimidazolium hydrogen sulfate, 0.1% 1-vinyl-3-methylimidazolium hexafluorophosphate and 93.9% water offered the acceptable extract efficiency that are comparable to or even better than conventional volatile organic solvents. This assay was fully validated with respect to the linearity of response (r(2) > 0.999 over two orders of magnitude), precision (intra-RSD < 0.49 and inter-day RSD < 2.21), and accuracy (recoveries ranging from 93.73% to 101.84%). The proposed IL-in-water microemulsion method provided an environmentally friendly alternative for efficient extraction of compounds from Flos Chrysanthemi and could be extended to complex environmental and pharmaceutical samples.
Development of andrographolide molecularly imprinted polymer for solid-phase extraction
NASA Astrophysics Data System (ADS)
Yin, Xiaoying; Liu, Qingshan; Jiang, Yifan; Luo, Yongming
2011-06-01
A method employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) to pretreat samples was developed. The polymers were prepared by precipitation polymerization with andrographolide as template molecule. The structure of MIP was characterized and its static adsorption capacity was measured by the Scatchard equation. In comparison with C 18-SPE and non-imprinted polymer (NIP) SPE column, MIP-SPE column displays high selectivity and good affinity for andrographolide and dehydroandrographolide for extract of herb Andrographis paniculata ( Burm.f.) Nees (APN). MIP-SPE column capacity was 11.9 ± 0.6 μmol/g and 12.1 ± 0.5 μmol/g for andrographolide and dehydroandrographolide, respectively and was 2-3 times higher than that of other two columns. The precision and accuracy of the method developed were satisfactory with recoveries between 96.4% and 103.8% (RSD 3.1-4.3%, n = 5) and 96.0% and 104.2% (RSD 2.9-3.7%, n = 5) for andrographolide and dehydroandrographolide, respectively. Various real samples were employed to confirm the feasibility of method. This developed method demonstrates the potential of molecularly imprinted solid phase extraction for rapid, selective, and effective sample pretreatment.
Fajar, N M; Carro, A M; Lorenzo, R A; Fernandez, F; Cela, R
2008-08-01
The efficiency of microwave-assisted extraction with saponification (MAES) for the determination of seven polybrominated flame retardants (polybrominated biphenyls, PBBs; and polybrominated diphenyl ethers, PBDEs) in aquaculture samples is described and compared with microwave-assisted extraction (MAE). Chemometric techniques based on experimental designs and desirability functions were used for simultaneous optimization of the operational parameters used in both MAES and MAE processes. Application of MAES to this group of contaminants in aquaculture samples, which had not been previously applied to this type of analytes, was shown to be superior to MAE in terms of extraction efficiency, extraction time and lipid content extracted from complex matrices (0.7% as against 18.0% for MAE extracts). PBBs and PBDEs were determined by gas chromatography with micro-electron capture detection (GC-muECD). The quantification limits for the analytes were 40-750 pg g(-1) (except for BB-15, which was 1.43 ng g(-1)). Precision for MAES-GC-muECD (%RSD < 11%) was significantly better than for MAE-GC-muECD (%RSD < 20%). The accuracy of both optimized methods was satisfactorily demonstrated by analysis of appropriate certified reference material (CRM), WMF-01.
Development of a solenoid pumped in situ zinc analyzer for environmental monitoring
Chapin, T.P.; Wanty, R.B.
2005-01-01
A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 ??g L-1. Precision was 5-10% relative standard deviation (R.S.D.) below 100 ??g L-1, improving to 1% R.S.D. at 1000 ??g L-1. The linear range extended from 30 to 3000 ??g L-1. In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector. ?? 2005 Elsevier B.V. All rights reserved.
Liu, Jingjing; Meng, Xiangpeng; Chan, Wan
2016-02-17
Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.
Dowling, Geraldine; Malone, Edward; Harbison, Tom; Martin, Sheila
2010-07-01
A sensitive and selective method for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in bovine plasma was developed. An improved method for the determination of authorized and non-authorized residues of 10 non-steroidal anti-inflammatory drugs in milk was developed. Analytes were separated and acquired by high performance liquid chromatography coupled with an electrospray ionisation tandem mass spectrometer (ESI-MS/MS). Target compounds were acidified in plasma, and plasma and milk samples were extracted with acetonitrile and both extracts were purified on an improved solid phase extraction procedure utilising Evolute ABN cartridges. The accuracy of the methods for milk and plasma was between 73 and 109%. The precision of the method for authorized and non-authorized NSAIDs in milk and plasma expressed as % RSD, for the within lab reproducibility was less than 16%. The % RSD for authorized NSAIDs at their associated MRL(s) in milk was less than 10% for meloxicam, flunixin and tolfenamic acid and was less than 25% for hydroxy flunixin. The methods were validated according to Commission Decision 2002/657/EC.
Telltale Signs and Symptoms of CRPS/RSD
... Living With CRPS/RSD Symptoms of CRPS/RSD Definition of CRPS Diagnosed: Now What? Coping Strategies Caregivers CRPS Comfortable Clothing For Youth Stories of Hope Research/Medical Clinical Guidelines Treatments Educational Presentations RSDSA Videos Accredited Course ...
Qian, Yiyun; Zhu, Zhenhua; Duan, Jin-Ao; Guo, Sheng; Shang, Erxin; Tao, Jinhua; Su, Shulan; Guo, Jianming
2017-01-15
A highly sensitive method using ultra-high-pressure liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MS) has been developed and validated for the simultaneous identification and quantification of ginkgolic acids and semi-quantification of their metabolites in rat plasma. For the five selected ginkgolic acids, the method was found to be with good linearities (r>0.9991), good intra- and inter-day precisions (RSD<15%), and good accuracies (RE, from -10.33% to 4.92%) as well. Extraction recoveries, matrix effects and stabilities for rat plasm samples were within the required limits. The validated method was successfully applied to investigate the pharmacokinetics of the five ginkgolic acids in rat plasma after oral administration of 3 dosage groups (900mg/kg, 300mg/kg and 100mg/kg). Meanwhile, six metabolites of GA (15:1) and GA (17:1) were identified by comparison of MS data with reported values. The results of validation in terms of linear ranges, precisions and stabilities were established for semi-quantification of metabolites. The curves of relative changes of these metabolites during the metabolic process were constructed by plotting the peak area ratios of metabolites to salicylic acid (internal standard, IS), respectively. Double peaks were observed in all 3 dose groups. Different type of metabolites and different dosage of each metabolite both resulted in different T max . Copyright © 2016 Elsevier B.V. All rights reserved.
Poitevin, Eric
2012-01-01
A single-laboratory validation (SLV) and a ring trial (RT) were undertaken to determine nine nutritional elements in food products by inductively coupled plasma-optical emission spectrometry in order to modernize AOAC Official Method 984.27. The improvements involved extension of the scope to all food matrixes (including infant formula), optimized microwave digestion, selected analytical lines, internal standardization, and ion buffering. Simultaneous determination of nine elements (calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc) was made in food products. Sample digestion was performed through wet digestion of food samples by microwave technology with either closed- or open-vessel systems. Validation was performed to characterize the method for selectivity, sensitivity, linearity, accuracy, precision, recovery, ruggedness, and uncertainty. The robustness and efficiency of this method was proven through a successful RT using experienced independent food industry laboratories. Performance characteristics are reported for 13 certified and in-house reference materials, populating the AOAC triangle food sectors, which fulfilled AOAC criteria and recommendations for accuracy (trueness, recovery, and z-scores) and precision (repeatability and reproducibility RSD, and HorRat values) regarding SLVs and RTs. This multielemental method is cost-efficient, time-saving, accurate, and fit-for-purpose according to ISO 17025 Norm and AOAC acceptability criteria, and is proposed as an extended updated version of AOAC Official Method 984.27 for fortified food products, including infant formula.
Durante, Caterina; Baschieri, Carlo; Bertacchini, Lucia; Bertelli, Davide; Cocchi, Marina; Marchetti, Andrea; Manzini, Daniela; Papotti, Giulia; Sighinolfi, Simona
2015-04-15
Geographical origin and authenticity of food are topics of interest for both consumers and producers. Among the different indicators used for traceability studies, (87)Sr/(86)Sr isotopic ratio has provided excellent results. In this study, two analytical approaches for wine sample pre-treatment, microwave and low temperature mineralisation, were investigated to develop accurate and precise analytical method for (87)Sr/(86)Sr determination. The two procedures led to comparable results (paired t-test, with t
Wang, Guangji; Wang, Qian; Rao, Tai; Shen, Boyu; Kang, Dian; Shao, Yuhao; Xiao, Jingcheng; Chen, Huimin; Liang, Yan
2016-06-15
Pidotimod, (R)-3-[(S)-(5-oxo-2-pyrrolidinyl) carbonyl]-thiazolidine-4-carboxylic acid, was frequently used to treat children with recurrent respiratory infections. Preclinical pharmacokinetics of pidotimod was still rarely reported to date. Herein, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to determine pidotimod in rat plasma, tissue homogenate and Caco-2 cells. In this process, phenacetin was chosen as the internal standard due to its similarity in chromatographic and mass spectrographic characteristics with pidotimod. The plasma calibration curves were established within the concentration range of 0.01-10.00μg/mL, and similar linear curves were built using tissue homogenate and Caco-2 cells. The calibration curves for all biological samples showed good linearity (r>0.99) over the concentration ranges tested. The intra- and inter-day precision (RSD, %) values were below 15% and accuracy (RE, %) was ranged from -15% to 15% at all quality control levels. For plasma, tissue homogenate and Caco-2 cells, no obvious matrix effect was found, and the average recoveries were all above 75%. Thus, the method demonstrated excellent accuracy, precision and robustness for high throughput applications, and was then successfully applied to the studies of absorption in rat plasma, distribution in rat tissues and intracellular uptake characteristics in Caco-2 cells for pidotimod. Copyright © 2016 Elsevier B.V. All rights reserved.
El-Ashry, S M; El-Wasseef, D R; El-Sherbiny, D T; Salem, Y A
2015-09-01
Two simple, rapid, sensitive and precise spectrophotometric and spectrofluorimetric methods were developed for the determination of indacaterol maleate in bulk powder and capsules. Both methods were based on the direct measurement of the drug in methanol. In the spectrophotometric method (Method I) the absorbance was measured at 259 nm. The absorbance-concentration plot was rectilinear over the range 1.0-10.0 µg mL(-1) with a lower detection limit (LOD) of 0.078 µg mL(-1) and lower quantification limit (LOQ) of 0.238 µg mL(-1). Meanwhile in the spectrofluorimetric method (Method II) the native fluorescence was measured at 358 nm after excitation at 258 nm. The fluorescence-concentration plot was rectilinear over the range of 1.0-40.0 ng mL(-1) with an LOD of 0.075 ng mL(-1) and an LOQ of 0.226 ng mL(-1). The proposed methods were successfully applied to the determination of indacaterol maleate in capsules with average percent recoveries ± RSD% of 99.94 ± 0.96 for Method I and 99.97 ± 0.81 for Method II. In addition, the proposed methods were extended to a content uniformity test according to the United States Pharmacopoeia (USP) guidelines and were accurate, precise for the capsules studied with acceptance value 3.98 for Method I and 2.616 for Method II. Copyright © 2015 John Wiley & Sons, Ltd.
Poitevin, Eric; Nicolas, Marine; Graveleau, Laetitia; Richoz, Janique; Andrey, Daniel; Monard, Florence
2009-01-01
A single-laboratory validation (SLV) and a ring trial (RT) were undertaken to determine nine nutritional elements in food products by inductively coupled plasma-atomic emission spectroscopy in order to improve and update AOAC Official Method 984.27. The improvements involved optimized microwave digestion, selected analytical lines, internal standardization, and ion buffering. Simultaneous determination of nine elements (calcium, copper, iron, potassium, magnesium, manganese, sodium, phosphorus, and zinc) was made in food products. Sample digestion was performed through wet digestion of food samples by microwave technology with either closed or open vessel systems. Validation was performed to characterize the method for selectivity, sensitivity, linearity, accuracy, precision, recovery, ruggedness, and uncertainty. The robustness and efficiency of this method was proved through a successful internal RT using experienced food industry laboratories. Performance characteristics are reported for 13 certified and in-house reference materials, populating the AOAC triangle food sectors, which fulfilled AOAC criteria and recommendations for accuracy (trueness, recovery, and z-scores) and precision (repeatability and reproducibility RSD and HorRat values) regarding SLV and RT. This multielemental method is cost-efficient, time-saving, accurate, and fit-for-purpose according to ISO 17025 Norm and AOAC acceptability criteria, and is proposed as an improved version of AOAC Official Method 984.27 for fortified food products, including infant formula.
Pina, Athanasia; Begou, Olga; Kanelis, Dimitris; Gika, Helen; Kalogiannis, Stavros; Tananaki, Chrysoula; Theodoridis, Georgios; Zotou, Anastasia
2018-01-05
In the present work a Hydrophilic Interaction Liquid Chromatography-tandem Mass Spectrometry (HILIC-MS/MS) method was developed for the efficient separation and quantification of a large number of small polar bioactive molecules in Royal Jelly. The method was validated and provided satisfactory detection sensitivity for 88 components. Quantification was proven to be precise for 64 components exhibiting good linearity, recoveries R% >90% for the majority of analytes and intra- and inter-day precision from 0.14 to 20% RSD. Analysis of 125 fresh royal jelly samples of Greek origin provided useful information on royal jelly's hydrophilic bioactive components revealing lysine, ribose, proline, melezitose and glutamic acid to be in high abundance. In addition the occurrence of 18 hydrophilic nutrients which have not been reported previously as royal jelly constituents is shown. Copyright © 2017 Elsevier B.V. All rights reserved.
Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El
2017-06-27
HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.
Wang, Xinyu; Gao, Jing-Lin; Du, Chaohui; An, Jing; Li, MengJiao; Ma, Haiyan; Zhang, Lina; Jiang, Ye
2017-01-01
People today have a stronger interest in the risk of biosafety in clinical bioanalysis. A safe, simple, effective method of preparation is needed urgently. To improve biosafety of clinical analysis, we used antiviral drugs of adefovir and tenofovir as model drugs and developed a safe pretreatment method combining sealing technique with direct injection technique. The inter- and intraday precision (RSD %) of the method were <4%, and the extraction recoveries ranged from 99.4 to 100.7%. Meanwhile, the results showed that standard solution could be used to prepare calibration curve instead of spiking plasma, acquiring more accuracy result. Compared with traditional methods, the novel method not only improved biosecurity of the pretreatment method significantly, but also achieved several advantages including higher precision, favorable sensitivity and satisfactory recovery. With these highly practical and desirable characteristics, the novel method may become a feasible platform in bioanalysis.
Li, Peng; Huang, Pei-Pei; Yang, Yun; Liu, Chi; Lu, Yan; Wang, Fang; Sun, Wei; Kong, Xiang-Qing
2017-01-01
Li P, Huang P, Yang Y, Liu C, Lu Y, Wang F, Sun W, Kong X. Renal sympathetic denervation attenuates hypertension and vascular remodeling in renovascular hypertensive rats. J Appl Physiol 122: 121-129, 2017. First published October 14, 2016; doi:10.1152/japplphysiol.01019.2015-Sympathetic activity is enhanced in patients with essential or secondary hypertension, as well as in various hypertensive animal models. Therapeutic targeting of sympathetic activation is considered an effective antihypertensive strategy. We hypothesized that renal sympathetic denervation (RSD) attenuates hypertension and improves vascular remodeling and renal disease in the 2-kidney, 1-clip (2K1C) rat model. Rats underwent 2K1C modeling or sham surgery; then rats underwent RSD or sham surgery 4 wk later, thus resulting in four groups (normotensive-sham, normotensive-RSD, 2K1C-sham, and 2K1C-RSD). Norepinephrine was measured by ELISA. Echocardiography was used to assess heart function. Fibrosis and apoptosis were assessed by Masson and TUNEL staining. Changes in mean arterial blood pressure in response to hexamethonium and plasma norepinephrine levels were used to evaluate basal sympathetic nerve activity. The 2K1C modeling success rate was 86.8%. RSD reversed the elevated systolic blood pressure induced by 2K1C, but had no effect on body weight. Compared with rats in the 2K1C-sham group, rats in the 2K1C-RSD group showed lower left ventricular mass/body weight ratio, interventricular septal thickness in diastole, left ventricular end-systolic diameter, and left ventricular posterior wall thickness in systole, whereas fractional shortening and ejection fraction were higher. Right kidney apoptosis and left kidney hypertrophy were not changed by RSD. Arterial fibrosis was lower in animals in the 2K1C-RSD group compared with those in the 2K1C-sham group. RSD reduced plasma norepinephrine and basal sympathetic activity in rats in the 2K1C-RSD group compared with rats in the 2K1C-sham group. These results suggest a possible clinical efficacy of RSD for renovascular hypertension. The effects of renal sympathetic denervation (RSD) on hypertension, cardiac function, vascular fibrosis, and renal apoptosis were studied in the 2K1C rat model. Results showed that RSD attenuated hypertension, improved vascular remodeling, and reduced vascular fibrosis through decreased sympathetic activity in the 2K1C rat model, but it did not change the kidney size, renal apoptosis, or renal caspase-3 expression. These results could suggest possible clinical efficacy of RSD for renovascular hypertension. Copyright © 2017 the American Physiological Society.
Determination of aliskiren in tablet dosage forms by a validated stability-indicating RP-LC method.
Wrasse-Sangoi, M; Sangoi, M S; Oliveira, P R; Secretti, L T; Rolim, C M B
2011-02-01
A reversed-phase liquid chromatography (RP-LC) method is validated for the determination of aliskiren in tablet dosage form. The LC method is carried out on a Waters XBridge C(18) column (150 × 4.6 mm i.d.), maintained at 25°C. The mobile phase consisted of acetonitrile:water (95:5, v/v)/phosphoric acid (25 mM, pH 3.0) (40:60, v/v), run at a flow rate of 1.0 mL/min, with photodiode array detector set at 229 nm. The chromatographic separation is obtained with aliskiren retention time of 3.68 min, and it is linear in the range of 10-300 μg/mL (r = 0.9999). The limits of detection and quantitation are 2.38 and 7.93 μg/mL, respectively. The specificity and stability-indicating capability of the method are proven through degradation studies, which also showed that there is no interference of the formulation excipients, showing that peak is free from any coeluting peak. The method showed adequate precision, with a relative standard deviation (RSD) values lower than 0.92%. Good values of accuracy were also obtained, with a mean value of 99.55%. Experimental design is used during validation to calculate method robustness. The proposed method is applied for the analysis of the tablet dosage forms, contributing to improve the quality control and to assure the therapeutic efficacy.
Takegami, Shigehiko; Kitamura, Keisuke; Ohsugi, Mayuko; Ito, Aya; Kitade, Tatsuya
2015-06-15
In order to quantitatively examine the lipophilicity of the widely used organophosphorus pesticides (OPs) chlorfenvinphos (CFVP), chlorpyrifos-methyl (CPFM), diazinon (DZN), fenitrothion (FNT), fenthion (FT), isofenphos (IFP), profenofos (PFF) and pyraclofos (PCF), their partition coefficient (Kp) values between phosphatidylcholine (PC) small unilamellar vesicles (SUVs) and water (liposome-water system) were determined by second-derivative spectrophotometry. The second-derivative spectra of these OPs in the presence of PC SUV showed a bathochromic shift according to the increase in PC concentration and distinct derivative isosbestic points, demonstrating the complete elimination of the residual background signal effects that were observed in the absorption spectra. The Kp values were calculated from the second-derivative intensity change induced by addition of PC SUV and obtained with a good precision of R.S.D. below 10%. The Kp values were in the order of CPFM>FT>PFF>PCF>IFP>CFVP>FNT⩾DZN and did not show a linear correlation relationship with the reported partition coefficients obtained using an n-octanol-water system (R(2)=0.530). Also, the results quantitatively clarified the effect of chemical-group substitution in OPs on their lipophilicity. Since the partition coefficient for the liposome-water system is more effective for modeling the quantitative structure-activity relationship than that for the n-octanol-water system, the obtained results are toxicologically important for estimating the accumulation of these OPs in human cell membranes. Copyright © 2015 Elsevier B.V. All rights reserved.
Li, Jing; Ma, Bo; Zhang, Qi; Yang, Xiaojing; Sun, Jingjing; Tang, Bowen; Cui, Guangbo; Yao, Di; Liu, Lei; Gu, Guiying; Zhu, Jianwei; Wei, Ping; Ouyang, Pingkai
2014-11-01
A highly selective and sensitive method for simultaneous quantitation of osthole, bergapten and isopimpinellin in rat plasma and tissues was developed by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). After liquid-liquid extraction of samples with methyl tert-butyl ether, the analytes and dextrorphan (internal standard, IS) were separated by a Hypersil GOLD AQ C18 column with gradient elution of acetonitrile and water containing 0.5‰ formic acid. Three determinands were detected using an electrospray ionization (ESI) tandem mass spectrometry in the multiple reaction monitoring (MRM) modes with positive electrospray ionization. Calibration curves were recovered over the concentration ranges of 1-200 ng/ml, 1-500 ng/ml, 0.25-200 ng/ml for osthole, bergapten and isopimpinellin in plasma; 1-100 ng/ml, 1-500 ng/ml, 0.5-100 ng/ml for osthole, bergapten and isopimpinellin in tissues, respectively. The intra-day precision (R.S.D.) was within 13.90% and the intra-day accuracy (R.E.) was within -6.27 to 6.84% in all biological matrixes. The inter-day precision (R.S.D.) was less than 13.66% and the inter-day accuracy (R.E.) was within -10.64 to 13.04%. Then the method was successfully applied to investigate plasma pharmacokinetic study and tissue distribution of osthole, bergapten and isopimpinellin in rats after oral administration of Fructus Cnidii extraction, especially for testis/uterus tissue distribution. The results demonstrated that osthole, bergapten and isopimpinellin were absorbed and eliminated rapidly with wide distributions in rats. Distribution data of these three bioactive components in testis/uterus tissues could offer useful information for the further preclinical and clinical studies of Fructus Cnidii in the treatment of genital system disease. Copyright © 2014 Elsevier B.V. All rights reserved.
Alonso Sobrado, Laura; Robledo Fernández, Mario; Cueto Díaz, Sergio; Ruiz Encinar, Jorge; García Alonso, J Ignacio
2015-11-06
We describe the instrumental modification of a commercial gas chromatography isotope ratio mass spectrometer (GC-IRMS) and its application for on-line carbon isotope dilution. The main modification consisted in the addition of a constant flow of enriched (13)CO2 diluted in helium after the chromatographic column through the splitter holder located inside the chromatographic oven of the instrument. In addition, and in contrast to the conventional mode of operation of GC-IRMS instruments where the signal at m/z 45 is amplified 100-fold with respect to the signal at m/z 44, the same signal amplification was used in both Faraday cups at m/z 44 and 45. Under these conditions isotope ratio precision for the ratio 44/45 was around 0.05% RSD (n=50). The evaluation of the instrument was performed with mixtures of organic compounds including 11 n-alkanes, 16 PAHs, 12 PCBs and 3 benzothiophenes. It was observed that compounds of very different boiling points could be analysed without discrimination in the injector when a Programmable Temperature Vaporizer (PTV) injector was employed. Moreover, the presence of heteroatoms (Cl or S) in the structure of the organic compounds did not affect their combustion efficiency and therefore the trueness of the results. Quantitative results obtained for all the analytes assayed were excellent in terms of precision (<3% RSD) and accuracy (average relative error≤4%) and what is more important using a single and simple generic internal standard for quantification. Copyright © 2015 Elsevier B.V. All rights reserved.
Valen, Anja; Leere Øiestad, Åse Marit; Strand, Dag Helge; Skari, Ragnhild; Berg, Thomas
2017-05-01
Collection of oral fluid (OF) is easy and non-invasive compared to the collection of urine and blood, and interest in OF for drug screening and diagnostic purposes is increasing. A high-throughput ultra-high-performance liquid chromatography-tandem mass spectrometry method for determination of 21 drugs in OF using fully automated 96-well plate supported liquid extraction for sample preparation is presented. The method contains a selection of classic drugs of abuse, including amphetamines, cocaine, cannabis, opioids, and benzodiazepines. The method was fully validated for 200 μL OF/buffer mix using an Intercept OF sampling kit; validation included linearity, sensitivity, precision, accuracy, extraction recovery, matrix effects, stability, and carry-over. Inter-assay precision (RSD) and accuracy (relative error) were <15% and 13 to 5%, respectively, for all compounds at concentrations equal to or higher than the lower limit of quantification. Extraction recoveries were between 58 and 76% (RSD < 8%), except for tetrahydrocannabinol and three 7-amino benzodiazepine metabolites with recoveries between 23 and 33% (RSD between 51 and 52 % and 11 and 25%, respectively). Ion enhancement or ion suppression effects were observed for a few compounds; however, to a large degree they were compensated for by the internal standards used. Deuterium-labelled and 13 C-labelled internal standards were used for 8 and 11 of the compounds, respectively. In a comparison between Intercept and Quantisal OF kits, better recoveries and fewer matrix effects were observed for some compounds using Quantisal. The method is sensitive and robust for its purposes and has been used successfully since February 2015 for analysis of Intercept OF samples from 2600 cases in a 12-month period. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Spectrophotometric determination of flucloxacillin and dicloxacillin in pure and dosage forms
NASA Astrophysics Data System (ADS)
El-Dien, F. A. Nour; Mohamed, Gehad G.; Farag, Eman Y. Z. A.
2006-05-01
A simple, rapid and accurate spectrophotometric method for the determination of antibiotic drugs, flucloxacillin (Fluclox) and dicloxacillin (Diclox), in pure form and different pharmaceutical preparations has been developed. The charge transfer (CT) reactions between Fluclox and Diclox as electron donors and 7,7,8,8-tetracyanoquinodimethane (TCNQ) and tetracyanoethylene (TCNE) as π-acceptors to give highly coloured complex species have been spectrophotometrically studied. The optimum experimental conditions for these CT reactions have been studied carefully. Beer's law is obeyed over the concentration ranges of 4-180 μg mL -1 and 4-70 μg mL -1 for Fluclox and Diclox drugs using TCNQ and TCNE reagents, respectively. The Sandell sensitivities ( S) are found to be 0.016-0.035 μg cm -2 and 0.011-0.016 μg cm -2 for Fluclox and Diclox, respectively, which indicate the high sensitivity of the proposed method. The relative standard deviations (R.S.D.: 0.08-0.49 and 0.15-0.80) for the determination of Fluclox and (R.S.D.: 0.05-0.75 and 0.13-0.75) for Diclox were obtained for four to six replicates using TCNQ and TCNE reagents, respectively, refer to the high accuracy and precision of the proposed method. These results are also confirmed by the between-day precision and the percent recovery of 99.90-100.1 and 99.60-100.4 for Fluclox and 99.90-100.5 and 99.40-100.1 for Diclox using TNCQ and TCNE reagents, respectively. The results obtained for the two reagents are comparable with those obtained by the official method.
Saviano, Alessandro Morais; Francisco, Fabiane Lacerda; Ostronoff, Celina Silva; Lourenço, Felipe Rebello
2015-01-01
The aim of this study was to develop, optimize, and validate a microplate bioassay for relative potency determination of linezolid in pharmaceutical samples using quality-by-design and design space approaches. In addition, a procedure is described for estimating relative potency uncertainty based on microbiological response variability. The influence of culture media composition was studied using a factorial design and a central composite design was adopted to study the influence of inoculum proportion and triphenyltetrazolium chloride in microbial growth. The microplate bioassay was optimized regarding the responses of low, medium, and high doses of linezolid, negative and positive controls, and the slope, intercept, and correlation coefficient of dose-response curves. According to optimization results, design space ranges were established using: (a) low (1.0 μg/mL), medium (2.0 μg/mL), and high (4.0 μg/mL) doses of pharmaceutical samples and linezolid chemical reference substance; (b) Staphylococcus aureus ATCC 653 in an inoculum proportion of 10%; (c) antibiotic No. 3 culture medium pH 7.0±0.1; (d) 6 h incubation at 37.0±0.1ºC; and (e) addition of 50 μL of 0.5% (w/v) triphenyltetrazolium chloride solution. The microplate bioassay was linear (r2=0.992), specific, precise (repeatability RSD=2.3% and intermediate precision RSD=4.3%), accurate (mean recovery=101.4%), and robust. The overall measurement uncertainty was reasonable considering the increased variability inherent in microbiological response. Final uncertainty was comparable with those obtained with other microbiological assays, as well as chemical methods.
The extended Baryon Oscillation Spectroscopic Survey: a cosmological forecast
NASA Astrophysics Data System (ADS)
Zhao, Gong-Bo; Wang, Yuting; Ross, Ashley J.; Shandera, Sarah; Percival, Will J.; Dawson, Kyle S.; Kneib, Jean-Paul; Myers, Adam D.; Brownstein, Joel R.; Comparat, Johan; Delubac, Timothée; Gao, Pengyuan; Hojjati, Alireza; Koyama, Kazuya; McBride, Cameron K.; Meza, Andrés; Newman, Jeffrey A.; Palanque-Delabrouille, Nathalie; Pogosian, Levon; Prada, Francisco; Rossi, Graziano; Schneider, Donald P.; Seo, Hee-Jong; Tao, Charling; Wang, Dandan; Yèche, Christophe; Zhang, Hanyu; Zhang, Yuecheng; Zhou, Xu; Zhu, Fangzhou; Zou, Hu
2016-04-01
We present a science forecast for the extended Baryon Oscillation Spectroscopic Survey (eBOSS) survey. Focusing on discrete tracers, we forecast the expected accuracy of the baryonic acoustic oscillation (BAO), the redshift-space distortion (RSD) measurements, the fNL parameter quantifying the primordial non-Gaussianity, the dark energy and modified gravity parameters. We also use the line-of-sight clustering in the Lyman α forest to constrain the total neutrino mass. We find that eBOSS luminous red galaxies, emission line galaxies and clustering quasars can achieve a precision of 1, 2.2 and 1.6 per cent, respectively, for spherically averaged BAO distance measurements. Using the same samples, the constraint on fσ8 is expected to be 2.5, 3.3 and 2.8 per cent, respectively. For primordial non-Gaussianity, eBOSS alone can reach an accuracy of σ(fNL) ˜ 10-15. eBOSS can at most improve the dark energy figure of merit by a factor of 3 for the Chevallier-Polarski-Linder parametrization, and can well constrain three eigenmodes for the general equation-of-state parameter. eBOSS can also significantly improve constraints on modified gravity parameters by providing the RSD information, which is highly complementary to constraints obtained from weak lensing measurements. A principal component analysis shows that eBOSS can measure the eigenmodes of the effective Newton's constant to 2 per cent precision; this is a factor of 10 improvement over that achievable without eBOSS. Finally, we derive the eBOSS constraint (combined with Planck, Dark Energy Survey and BOSS) on the total neutrino mass, σ(Σmν) = 0.03 eV (68 per cent CL), which in principle makes it possible to distinguish between the two scenarios of neutrino mass hierarchies.
Kääriä, K; Hirvonen, A; Norppa, H; Piirilä, P; Vainio, H; Rosenberg, C
2001-04-01
Occupational exposure to 4,4'-methylenediphenyl diisocyanate (MDI) was measured during moulding of rigid polyurethane foam. The aim of the study was to find out whether an MDI-derived urinary amine metabolite could be detected in the urine of workers exposed to apparently low levels of MDI. Airborne MDI was sampled on 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters and determined by high-performance liquid chromatography (HPLC) using ultraviolet (UV) and electrochemical (EC) detection. The limit of detection of MDI was 3 ng ml-1 for a 20 microliters injection. The precision of sample preparation, expressed as relative standard deviation (RSD), was 1.3% with UV detection and 2.1% with EC detection at a concentration of 70 ng MDI ml-1 (n = 6). The 2MP-MDI derivative was stable at +4 degrees C up to eight weeks. The accuracy of the method was validated in an international quality control programme. Workers (n = 57) from three different factories participated in the study. Urinary 4,4'-methylenedianiline (MDA) metabolite was determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry using chemical ionisation and monitoring negative ions. The limit of detection in urine was 0.2 nmol l-1. The precision of six analyses for a urine sample spiked to a concentration of 1 nmol l-1 was 29% (RSD). The MDI concentrations were below the limit of detection in most (64%) of the air samples collected in the worker's breathing zone. Still, detectable amounts of MDA were found in 97% of the urine samples. Monitoring of urinary MDA appears to be an appropriate method of assessing MDI exposure in work environments with low or undetectable MDI concentrations in the workplace air.
Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas
2014-10-21
In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.
Kirwan, J A; Broadhurst, D I; Davidson, R L; Viant, M R
2013-06-01
Direct infusion mass spectrometry (DIMS)-based untargeted metabolomics measures many hundreds of metabolites in a single experiment. While every effort is made to reduce within-experiment analytical variation in untargeted metabolomics, unavoidable sources of measurement error are introduced. This is particularly true for large-scale multi-batch experiments, necessitating the development of robust workflows that minimise batch-to-batch variation. Here, we conducted a purpose-designed, eight-batch DIMS metabolomics study using nanoelectrospray (nESI) Fourier transform ion cyclotron resonance mass spectrometric analyses of mammalian heart extracts. First, we characterised the intrinsic analytical variation of this approach to determine whether our existing workflows are fit for purpose when applied to a multi-batch investigation. Batch-to-batch variation was readily observed across the 7-day experiment, both in terms of its absolute measurement using quality control (QC) and biological replicate samples, as well as its adverse impact on our ability to discover significant metabolic information within the data. Subsequently, we developed and implemented a computational workflow that includes total-ion-current filtering, QC-robust spline batch correction and spectral cleaning, and provide conclusive evidence that this workflow reduces analytical variation and increases the proportion of significant peaks. We report an overall analytical precision of 15.9%, measured as the median relative standard deviation (RSD) for the technical replicates of the biological samples, across eight batches and 7 days of measurements. When compared against the FDA guidelines for biomarker studies, which specify an RSD of <20% as an acceptable level of precision, we conclude that our new workflows are fit for purpose for large-scale, high-throughput nESI DIMS metabolomics studies.
Jensen, Pamela K; Wujcik, Chad E; McGuire, Michelle K; McGuire, Mark A
2016-01-01
Simple high-throughput procedures were developed for the direct analysis of glyphosate [N-(phosphonomethyl)glycine] and aminomethylphosphonic acid (AMPA) in human and bovine milk and human urine matrices. Samples were extracted with an acidified aqueous solution on a high-speed shaker. Stable isotope labeled internal standards were added with the extraction solvent to ensure accurate tracking and quantitation. An additional cleanup procedure using partitioning with methylene chloride was required for milk matrices to minimize the presence of matrix components that can impact the longevity of the analytical column. Both analytes were analyzed directly, without derivatization, by liquid chromatography tandem mass spectrometry using two separate precursor-to-product transitions that ensure and confirm the accuracy of the measured results. Method performance was evaluated during validation through a series of assessments that included linearity, accuracy, precision, selectivity, ionization effects and carryover. Limits of quantitation (LOQ) were determined to be 0.1 and 10 µg/L (ppb) for urine and milk, respectively, for both glyphosate and AMPA. Mean recoveries for all matrices were within 89-107% at three separate fortification levels including the LOQ. Precision for replicates was ≤ 7.4% relative standard deviation (RSD) for milk and ≤ 11.4% RSD for urine across all fortification levels. All human and bovine milk samples used for selectivity and ionization effects assessments were free of any detectable levels of glyphosate and AMPA. Some of the human urine samples contained trace levels of glyphosate and AMPA, which were background subtracted for accuracy assessments. Ionization effects testing showed no significant biases from the matrix. A successful independent external validation was conducted using the more complicated milk matrices to demonstrate method transferability.
Han, Hai; Miyoshi, Yurika; Ueno, Kyoko; Okamura, Chieko; Tojo, Yosuke; Mita, Masashi; Lindner, Wolfgang; Zaitsu, Kiyoshi; Hamase, Kenji
2011-11-01
For a metabolomics study focusing on the analysis of aspartic and glutamic acid enantiomers, a fully automated two-dimensional HPLC system employing a microbore-ODS column and a narrowbore-enantioselective column was developed. By using this system, a detailed distribution of D-Asp and D-Glu besides L-Asp and L-Glu in mammals was elucidated. For the total analysis concept, the amino acids were first pre-column derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) to be sensitively and fluorometrically detected. For the non-stereoselective separation of the analytes in the first dimension a monolithic ODS column (750 mm × 0.53 mm i.d.) was adopted, and a self-packed narrowbore-Pirkle type enantioselective column (Sumichiral OA-2500S, 250 mm × 1.5 mm i.d.) was selected for the second dimension. In the rat plasma, RSD values for intra-day and inter-day precision were less than 6.8%, and the accuracy ranged between 96.1% and 105.8%. The values of LOQ of D-Asp and D-Glu were 5 fmol/injection (0.625 nmol/g tissue). The present method was successfully applied to the simultaneous determination of free aspartic acid and glutamic acid enantiomers in 7 brain areas, 11 peripheral tissues, plasma and urine of Wistar rats. Biologically significant D-Asp values were found in various tissue samples whereas for D-Glu the values were very low possibly indicating less significance. Copyright © 2011 Elsevier B.V. All rights reserved.
Quantitative TLC-Image Analysis of Urinary Creatinine Using Iodine Staining and RGB Values.
Kerr, Emily; West, Caroline; Kradtap Hartwell, Supaporn
2016-04-01
Digital image analysis of the separation results of colorless analytes on thin-layer chromatography (TLC) plates usually involves using specially tailored software to analyze the images generated from either a UV scanner or UV lamp station with a digital camera or a densitometer. Here, a low-cost alternative setup for quantitative TLC-digital image analysis is demonstrated using a universal staining reagent (iodine vapor), an office scanner and a commonly available software (Microsoft Paint) for analysis of red, green and blue colors (RGB values). Urinary creatinine is used as a model analyte to represent a sample in complicated biological matrices. Separation was carried out on a silica gel plate using a butanol-NH4OH-H2O (40 : 10 : 50, v/v) mobile phase with a 6-cm solvent front. It is important that the TLC plate be stained evenly and with sufficient staining time. Staining the TLC plate in a 23.4 × 18.8 × 6.8 cm chamber containing about 70 g iodine crystals yielded comparable results for the staining times of 30-60 min. The Green value offered the best results in the linear working range (0.0810-0.9260 mg/mL) and precision (2.03% RSD, n = 10). The detection limit was found to be 0.24 µg per 3 µL spot. Urinary creatinine concentrations determined by TLC-digital image analysis using the green value calibration graph agree well with results obtained from high-pressure liquid chromatography (HPLC). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Niglas, Mark; McCann, Claire; Keller, Brian M; Makhani, Nadiya; Presutti, Joseph; Vesprini, Danny; Rakovitch, Eileen; Elzibak, Alyaa; Mashouf, Shahram; Lee, Justin
2016-01-01
Breath-hold techniques can reduce cardiac dose in breast radiotherapy. The reverse semi-decubitus (RSD) technique is an alternative free-breathing method used at our centre. This study compares the dosimetry of free-breathing supine, RSD and moderate deep inspiration breath-hold (mDIBH) techniques. Twelve patients with left-sided breast cancer who were simulated using standard supine, RSD and mDIBH techniques were identified retrospectively. New plans using standard breast tangents and techniques for internal mammary chain (IMC) nodal coverage were assessed. Using standard tangents, mean heart dose, heart V25Gy and mean left anterior descending artery (LAD) dose were found to be significantly lower for RSD and mDIBH when compared to free-breathing supine (p ⩽ 0.03). Using wide-tangents, the maximum LAD point dose was also lower for RSD and mDIBH (p ⩽ 0.02). There were no statistically significant dosimetric differences found between the RSD and mDIBH simulation techniques for standard breast-tangent plans, though organ-at-risk doses were lower for mDIBH in wide-tangent plans. There was no improvement in cardiac dosimetry between RSD and free-breathing supine when using an electron field IMC plan. For patients unable to tolerate breath-hold, the RSD technique is an alternative approach that can reduce cardiac dose. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Park, Young Ha; Um, Si Hyeon; Song, Saemee; Seok, Yeong Jae; Ha, Nam Chul
2015-10-01
Histidine-containing phosphocarrier protein (HPr) is a general component of the bacterial phosphoenolpyruvate:sugar phosphotransferase system (PTS) involved in the phosphorylation-coupled transport of numerous sugars called PTS sugars. HPr mainly exists in a dephosphorylated form in the presence of PTS sugars in the medium, while its phosphorylation increases in the absence of PTS sugars. A recent study revealed that the dephosphorylated form of HPr binds and antagonizes the function of the antisigma factor Rsd. This anti-sigma factor sequesters the housekeeping sigma factor σ(70) to facilitate switching of the sigma subunit on RNA polymerase from σ(70) to the stress-responsive sigma factor σ(S) in stationary-phase cells. In this study, the structure of the complex of Rsd and HPr was determined at 2.1 Å resolution and revealed that the binding site for HPr on the surface of Rsd partly overlaps with that for σ(70). The localization of the phosphorylation site on HPr at the binding interface for Rsd explains why phosphorylation of HPr abolishes its binding to Rsd. The mutation of crucial residues involved in the HPr-Rsd interaction significantly influenced the competition between HPr and σ(70) for binding to Rsd both in vitro and in vivo. The results provide a structural basis for the linkage of global gene regulation to nutrient availability in the external environment.
Wang, Xule; Zhao, Qingyan; Huang, He; Tang, Yanhong; Xiao, Jinping; Dai, Zixuan; Yu, Shengbo; Huang, Congxin
2013-01-01
We have previously demonstrated that catheter-based renal sympathetic denervation (RSD) could suppress atrial fibrillation (AF) in canines with short-time rapid right atrial pacing (RAP). However, the role of renal denervation on atrial remodeling is unclear. The aim of the present study was to explore the long-term effect of RSD on the atrial remodeling during prolonged RAP. Twenty mongrel dogs were implanted with a high-frequency cardiac pacemaker with a transvenous lead inserted into the right atrial appendage. The dogs were divided into three groups: a sham-operated group (n = 6), the chronic RAP (CRAP) group (n = 7), and the CRAP+RSD group (n = 7). In the CRAP+RSD group, a pacemaker was implanted 6 weeks after RSD was performed bilaterally for recovery. RAP was maintained for 5 weeks in CRAP group and CRAP+RSD group. The plasma levels of Angiotensin II and aldosterone were significantly increased in CRAP group compared with sham-operated group, but the increasing trend was inhibited in CRAP+RSD group compared with CRAP group (P<0.05). Similarly, RSD suppressed the increasing trend that prolonged RAP produced in the left atrial levels of ANP, TNF-α and IL-6. Compared with the sham-operated group, the CRAP group had significantly increased levels of caspase-3, bax and Cx40 whereas the level of Bcl-2 decreased (P<0.05). RSD markedly reduced the upregulation of caspase-3, bax and Cx40 and the downregulation of Bcl-2 expression compared with the CRAP group (P<0.05). Picric acid-sirius red staining study suggested that RSD could markedly alleviate the lesion degree of cardic fibrosis induced by CRAP (P<0.05). Immunohistochemistry results showed that the densities of TH- and GAP43- positive nerves were significantly elevated in the CRAP group compared with the sham-operated group, while RSD operation signicantly inhibited the these changes produced by CRAP. These findings suggest that renal denervation could suppress the atrial remodeling after prolonged RAP in ambulatory canines.
Wang, Xule; Zhao, Qingyan; Huang, He; Tang, Yanhong; Xiao, Jinping; Dai, Zixuan; Yu, Shengbo; Huang, Congxin
2013-01-01
We have previously demonstrated that catheter-based renal sympathetic denervation (RSD) could suppress atrial fibrillation (AF) in canines with short-time rapid right atrial pacing (RAP). However, the role of renal denervation on atrial remodeling is unclear. The aim of the present study was to explore the long-term effect of RSD on the atrial remodeling during prolonged RAP. Twenty mongrel dogs were implanted with a high-frequency cardiac pacemaker with a transvenous lead inserted into the right atrial appendage. The dogs were divided into three groups: a sham-operated group (n = 6), the chronic RAP (CRAP) group (n = 7), and the CRAP+RSD group (n = 7). In the CRAP+RSD group, a pacemaker was implanted 6 weeks after RSD was performed bilaterally for recovery. RAP was maintained for 5 weeks in CRAP group and CRAP+RSD group. The plasma levels of Angiotensin II and aldosterone were significantly increased in CRAP group compared with sham-operated group, but the increasing trend was inhibited in CRAP+RSD group compared with CRAP group (P<0.05). Similarly, RSD suppressed the increasing trend that prolonged RAP produced in the left atrial levels of ANP, TNF-α and IL-6. Compared with the sham-operated group, the CRAP group had significantly increased levels of caspase-3, bax and Cx40 whereas the level of Bcl-2 decreased (P<0.05). RSD markedly reduced the upregulation of caspase-3, bax and Cx40 and the downregulation of Bcl-2 expression compared with the CRAP group (P<0.05). Picric acid–sirius red staining study suggested that RSD could markedly alleviate the lesion degree of cardic fibrosis induced by CRAP (P<0.05). Immunohistochemistry results showed that the densities of TH- and GAP43- positive nerves were significantly elevated in the CRAP group compared with the sham-operated group, while RSD operation signicantly inhibited the these changes produced by CRAP. These findings suggest that renal denervation could suppress the atrial remodeling after prolonged RAP in ambulatory canines. PMID:23724069
Wang, Xule; Huang, Congxin; Zhao, Qingyan; Huang, He; Tang, Yanhong; Dai, Zixuan; Wang, Xiaozhan; Guo, Zongwen; Xiao, Jinping
2015-04-01
The aim of the present study was to explore the effect of renal sympathetic denervation (RSD) on the progression of paroxysmal atrial fibrillation (AF) in canines with long-term intermittent atrial pacing. Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (six dogs), and RSD group (seven dogs). Sham-operated group were implanted with pacemakers without pacing; control group were implanted with pacemakers with long-term intermittent atrial pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Atrial pacing was maintained for 8 h a day and a total of 12 weeks in the control group and RSD group. Echocardiography showed that the left atrial structure and function were significantly improved in the RSD group compared with the control group (P < 0.05). Compared with the control group, the RSD group had fewer incidences of AF and a shorter duration of AF (P < 0.05) after long-term intermittent atrial pacing. In addition to increased atrial effective refractory period (AERP) and AF cycle length, AERP dispersion and P-wave duration and dispersion were significantly decreased in the RSD group compared with the control group (P < 0.05). Atrial morphological evaluation suggested that fibrosis and ultrastructural changes induced by long-term intermittent atrial pacing were markedly suppressed in the RSD dogs compared with controls (P < 0.05). Immunohistochemistry results showed that connexin 43 distribution in RSD mid-myocardial was significantly fewer heterogeneous than that in control mid-myocardial (P < 0.05). Renal denervation inhibits the progression of paroxysmal AF, which might be related to the suppression of atrial electrophysiology and structural heterogeneity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Shafaei, Armaghan; Aisha, Abdalrahim F. A.; Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari
2015-01-01
Background: Ficus deltoidea (FD) is one of the native plants widely distributed in several countries in Southeast Asia. Previous studies have shown that FD leaf possess antinociceptive, wound healing and antioxidant properties. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids and flavonoids. Objective: The aim was to develop a reverse phase high-performance liquid chromatography method with ultraviolet detection that involves precolumn derivatisation with O-phthaladehyde for simultaneous analysis of two amino acids L-citrulline and L-arginine in FD leaf extracts. Materials and Methods: An isocratic elution program consisting of methanol: acetonitrile: Water at 45:45:10 v/v (solvent A) and 0.1 M phosphate buffer pH 7.5 (solvent B) at A: B v/v ratio of 80:20 on Zorbax Eclipse C18 SB-Aq column (250 × 4.6 mm, 5 μm) were used. The flow rate was set at 1 ml/min and detection was carried out at 338 nm with 30 min separation time. Results: Good linearity for L-citrulline and L-arginine was obtained in the range 0.1-1000 μg/ml at R2 ≥ 0.998. The limit of detection and limit of quantification values for both L-citrulline and L-arginine were 1 and 5 μg/ml, respectively. The average of recoveries was in the range 94.94-101.95%, with relative standard deviation (%RSD) less than 3%. Intra- and inter-day precision was in the range 96.36-102.43% with RSD less than 2%. Conclusion: All validation parameters of the developed method indicate the method is reliable and efficient for simultaneous determination of L-citrulline and L-arginine for routine analysis of FD. PMID:25598632
Panchal, Hiral J; Suhagia, Bhanubhai N
2010-01-01
Two simple and accurate methods to determine atorvastatin calcium and ramipril in capsule dosage forms were developed and validated using HPLC and HPTLC. The HPLC separation was achieved on a Phenomenex Luna C18 column (250 x 4.6 mm id, 5 microm) in the isocratic mode using 0.1% phosphoric acid-acetonitrile (38 + 62, v/v), pH 3.5 +/- 0.05, mobile phase at a flow rate of 1 ml/min. The retention times were 6.42 and 2.86 min for atorvastatin calcium and ramipril, respectively. Quantification was achieved with a photodiode array detector set at 210 nm over the concentration range of 0.5-5 microg/mL for each, with mean recoveries (at three concentration levels) of 100.06 +/- 0.49% and 99.95 +/- 0.63% RSD for atorvastatin calcium and ramipril, respectively. The HPTLC separation was achieved on silica gel 60 F254 HPTLC plates using methanol-benzene-glacial acetic acid (19.6 + 80.0 + 0.4, v/v/v) as the mobile phase. The Rf values were 0.40 and 0.20 for atorvastatin calcium and ramipril, respectively. Quantification was achieved with UV densitometry at 210 nm over the concentration range of 50-500 ng/spot for each, with mean recoveries (at three concentration levels) of 99.98 +/- 0.75% and 99.87 +/- 0.83% RSD for atorvastatin calcium and ramipril, respectively. Both methods were validated according to International Conference on Harmonization guidelines and found to be simple, specific, accurate, precise, and robust. The mean assay percentages for atorvastatin calcium and ramipril were 99.90 and 99.55% for HPLC and 99.91 and 99.47% for HPTLC, respectively. The methods were successfully applied for the determination of atorvastatin calcium and ramipril in capsule dosage forms without any interference from common excipients.
NASA Astrophysics Data System (ADS)
Goltz, Douglas; Boileau, Michael; Plews, Ian; Charleton, Kimberly; Hinds, Michael W.
2006-07-01
Spark ablation or electric dispersion of metal samples in aqueous solution can be a useful approach for sample preparation. The ablated metal forms a stable suspension that has been described as colloidal, which is easily dissolved with a small amount of concentrated (16 M) HNO 3. In this study, we have examined some of the properties of the spark ablation process for a variety of metals (Rh and Au) and alloys (stainless steel) using a low power spark (100-300 W). Particle size distributions and conductivity measurements were carried out on selected metals to characterize the stable suspensions. A LASER diffraction particle size analyzer was useful for showing that ablated particles varied in size from 1 to 30 μm for both the silver and the nickel alloy, Inconel. In terms of weight percent most of the particles were between 10 and 30 μm. Conductivity of the spark ablation solution was found to increase linearly for approximately 3 min before leveling off at approximately 300 S cm 3. These measurements suggest that a significant portion of the ablated metal is also ionic in nature. Scanning electron microscope measurements revealed that a low power spark is much less damaging to the metal surface than a high power spark. Crater formation of the low power spark was found in a wider area than expected with the highest concentration where the spark was directed. The feasibility of using spark ablation for metal dissolution of a valuable artifact such as gold was also performed. Determinations of Ag (4-12%) and Cu (1-3%) in Bullion Reference Material (BRM) gave results that were in very good agreement with the certified values. The precision was ± 0.27% for Ag at 4.15% (RSD = 6.5%) and ± 0.09% for Cu at 1% (RSD = 9.0%).
Handgrip strength deficits best explain limitations in performing bimanual activities after stroke.
Basílio, Marluce Lopes; de Faria-Fortini, Iza; Polese, Janaine Cunha; Scianni, Aline A; Faria, Christina Dcm; Teixeira-Salmela, Luci Fuscaldi
2016-04-01
[Purpose] To evaluate the relationships between residual strength deficits (RSD) of the upper limb muscles and the performance in bimanual activities and to determine which muscular group would best explain the performance in bimanual activities of chronic stroke individuals. [Subjects and Methods] Strength measures of handgrip, wrist extensor, elbow flexor/extensor, and shoulder flexor muscles of 107 subjects were obtained and expressed as RSD. The performance in bimanual activities was assessed by the ABILHAND questionnaire. [Results] The correlations between the RSD of handgrip and wrist extensor muscles with the ABILHAND scores were negative and moderate, whereas those with the elbow flexor/extensor and shoulder flexor muscles were negative and low. Regression analysis showed that the RSD of handgrip and wrist extensor muscles explained 38% of the variance in the ABILHAND scores. Handgrip RSD alone explained 33% of the variance. [Conclusion] The RSD of the upper limb muscles were negatively associated with the performance in bimanual activities and the RSD of handgrip muscles were the most relevant variable. It is possible that stroke subjects would benefit from interventions aiming at improving handgrip strength, when the goal is to increase the performance in bimanual activities.
Tramadol chronic abuse: an evidence from hair analysis by LC tandem MS.
Verri, Patrizia; Rustichelli, Cecilia; Palazzoli, Federica; Vandelli, Daniele; Marchesi, Filippo; Ferrari, Anna; Licata, Manuela
2015-01-01
Hair analysis, as complementary matrix, has expanded across the spectrum of toxicological investigations for misuse drug monitoring. Hair has become an important matrix for drug analysis, owing to the possibility to detect target analytes for long time periods, depending on hair length. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the quantitation of tramadol, a widely used centrally acting analgesic, and its main metabolites in hair (ODMT, NDMT, NOT). Hair samples were decontaminated and incubated overnight in diluted hydrochloric acid; the extracts were purified by mixed-mode solid phase cartridges and analyzed by LC-MS/MS in positive ionization mode monitoring two transitions per analyte. The procedure was fully validated in terms of linearity, limit of detection and lower limit of quantitation (LLOQ), accuracy, precision, recovery, matrix effect and selectivity. The linear regression analysis was calibrated by deuterated internal standards; for all analytes, responses were linear over the range 0.04-40.00 ng/mg hair, with R(2) values of at least 0.995. The method offered satisfactory precision (RSD < 10%), accuracy (90-110%) and recovery (> 90%) values. The found LLOQ values for tramadol and metabolites were in the range 0.010-0.030 ng/mg hair. The proposed procedure was successfully applied to quantify tramadol and metabolites in real hair samples submitted to our laboratory: three cases of tramadol assumption within the therapeutic dosage (3 × 2 segments) and one case of tramadol abuse in a binge pattern (8 segments). The ranges found for TRAM, ODMT, NDMT and NOT were markedly higher in the abuse case (63.42-107.30, 3.76-6.26, 24.88-45.66, 0.22-1.18 ng/mg hair, respectively) compared to the other case reports (3.29-20.12, 0.28-1.87, 0.45-4.32, 0.07-0.80 ng/mg, respectively); also the values of NMDT/ODMT ratio differed significantly. According to the obtained data, we hypothesized that the binge pattern may influence the metabolites' to parent drug concentration ratios; therefore this parameter could represent a target assessment tool to monitor abuse cases. Copyright © 2014 Elsevier B.V. All rights reserved.
Qiu, Min; Shan, Qijun; Chen, Chun; Geng, Jie; Guo, Jiqun; Zhou, Xiujuan; Qian, Weichong; Tang, Lijun; Yin, Yuehui
2016-02-01
The aim of this study was to investigate whether renal sympathetic denervation (RSD) improves ventricular heart rate (HR) control in patients with persistent atrial fibrillation (AF). Twenty-one patients (aged 57.5 ± 10.2 years, 76.2% male) with persistent AF and hypertension underwent RSD and completed 7-days follow-up evaluations, including 24-hour Holter monitoring (Holter), blood pressure (BP), 24-hour ambulatory BP monitoring (ABPM). Patients were grouped into tertiles of average HR at baseline Holter recording for evaluation of RSD effects on atrioventricular (AV) node (group 1: HR ≧ 90 bpm; group 2: 80 bpm ≦ HR < 90 bpm; group 3: HR < 80 bpm). All patients successfully underwent RSD without any complications. The clinical and procedural characteristics were similar in all groups of patients. No significant changes in BP were observed in the three groups before and after RSD. Compared with baseline, the average HR (Holter) of patients in group 1, 2 and 3 had a reduction of 22.6 ± 13.2 bpm (83.3 ± 4.9 vs 106.0 ± 14.6, P = 0.004), 9.7 ± 7.8 bpm (75.7 ± 7.6 vs 85.4 ± 3.7, P = 0.017) and 2.3 ± 2.9 bpm (71.4 ± 4.0 vs 73.7 ± 4.7, P = 0.089) at 7 days after RSD, respectively. RSD could improve ventricular HR control in patients with persistent AF. RSD slowed AV node conduction in baseline HR-dependent manner. RSD may become an alternative non-pharmaceutical tool for rate control in patients with persistent AF.
Wohleb, Eric S.; McKim, Daniel B.; Shea, Daniel T.; Powell, Nicole D.; Tarr, Andrew J.; Sheridan, John F.; Godbout, Jonathan P.
2014-01-01
Background Persistent anxiety-like symptoms may have an inflammatory-related pathophysiology. Our previous work using repeated social defeat (RSD) in mice showed that recruitment of peripheral myeloid cells to the brain is required for the development of anxiety. Here, we aimed to determine if 1) RSD promotes prolonged anxiety through redistribution of myeloid cells and 2) prior exposure to RSD sensitizes the neuroimmune axis to secondary subthreshold stress. Methods Mice were subjected to RSD and several immune and behavioral parameters were determined 0.5, 8, or 24 days later. In follow-up studies, control and RSD mice were subjected to subthreshold stress at 24 days. Results Repeated social defeat-induced macrophage recruitment to the brain corresponded with development and maintenance of anxiety-like behavior 8 days after RSD, but neither remained at 24 days. Nonetheless, social avoidance and an elevated neuroinflammatory profile were maintained at 24 days. Subthreshold social defeat in RSD-sensitized mice increased peripheral macrophage trafficking to the brain that promoted re-establishment of anxiety. Moreover, subthreshold social defeat increased social avoidance in RSD-sensitized mice compared with naïve mice. Stress-induced monocyte trafficking was linked to redistribution of myeloid progenitor cells in the spleen. Splenectomy before subthreshold stress attenuated macrophage recruitment to the brain and prevented anxiety-like behavior in RSD-sensitized mice. Conclusions These data indicate that monocyte trafficking from the spleen to the brain contributes re-establishment of anxiety in stress-sensitized mice. These findings show that neuroinflammatory mechanisms promote mood disturbances following stress-sensitization and outline novel neuroimmune interactions that underlie recurring anxiety disorders such as posttraumatic stress disorder. PMID:24439304
Skutan, Stefan; Aschenbrenner, Philipp
2012-12-01
Components with extraordinarily high analyte contents, for example copper metal from wires or plastics stabilized with heavy metal compounds, are presumed to be a crucial source of errors in refuse-derived fuel (RDF) analysis. In order to study the error generation of those 'analyte carrier components', synthetic samples spiked with defined amounts of carrier materials were mixed, milled in a high speed rotor mill to particle sizes <1 mm, <0.5 mm and <0.2 mm, respectively, and analyzed repeatedly. Copper (Cu) metal and brass were used as Cu carriers, three kinds of polyvinylchloride (PVC) materials as lead (Pb) and cadmium (Cd) carriers, and paper and polyethylene as bulk components. In most cases, samples <0.2 mm delivered good recovery rates (rec), and low or moderate relative standard deviations (rsd), i.e. metallic Cu 87-91% rec, 14-35% rsd, Cd from flexible PVC yellow 90-92% rec, 8-10% rsd and Pb from rigid PVC 92-96% rec, 3-4% rsd. Cu from brass was overestimated (138-150% rec, 13-42% rsd), Cd from flexible PVC grey underestimated (72-75% rec, 4-7% rsd) in <0.2 mm samples. Samples <0.5 mm and <1 mm spiked with Cu or brass produced errors of up to 220% rsd (<0.5 mm) and 370% rsd (<1 mm). In the case of Pb from rigid PVC, poor recoveries (54-75%) were observed in spite of moderate variations (rsd 11-29%). In conclusion, time-consuming milling to <0.2 mm can reduce variation to acceptable levels, even given the presence of analyte carrier materials. Yet, the sources of systematic errors observed (likely segregation effects) remain uncertain.
Kiuchi, Márcio G; Chen, Shaojie; E Silva, Gustavo R; Paz, Luis M R; Kiuchi, Tetsuaki; de Paula Filho, Ary G; Souto, Gladyston L L
2016-12-01
Atrial fibrillation (AF) commonly occurs in association with chronic kidney disease (CKD), resulting in adverse outcomes. Combining pulmonary vein isolation (PVI) and renal sympathetic denervation (RSD) may reduce the recurrence of AF in patients with CKD and hypertension. We considered that RSD could reduce the recurrence of AF in patients with CKD by modulating sympathetic hyperactivity. Our goal was to compare the impact of PVI + RSD with that of PVI alone in patients with concurrent AF and CKD. This was a single-center, prospective, longitudinal, randomized, double-blind study. Forty-five patients with controlled hypertension, symptomatic paroxysmal AF and/or persistent AF, stage 2 or 3 CKD, and a dual-chamber pacemaker were enrolled from January 2014 to January 2015. We assessed the 30-second recurrence of AF recorded by the pacemaker, 24-hour ambulatory blood pressure measurements, estimated glomerular filtration rate, albuminuria, echocardiographic parameters, and safety of RSD. No patient developed procedural or other complications. The ambulatory blood pressure measurements did not differ within the PVI + RSD group or between the PVI + RSD and PVI groups throughout the study. Significantly more patients in the PVI + RSD group than in the PVI group were free of AF at the 12-month follow-up evaluation. The PVI group had an unacceptable response to ablation with respect to changes in echocardiographic parameters, whereas these parameters improved in the PVI + RSD group. PVI + RSD were associated with a lower AF recurrence rate than PVI alone; it also improved renal function and some echocardiographic parameters. These encouraging data will serve as baseline information for further long-term studies on larger patient populations.
Huang, Bing; Yu, Lilei; He, Bo; Lu, Zhibing; Wang, Songyun; He, Wenbo; Yang, Kang; Liao, Kai; Zhang, Ling; Jiang, Hong
2014-11-01
Recently, a beneficial effect of renal sympathetic denervation (RSD) has been seen in patients with ventricular electrical storm. However, the effect of RSD on ventricular electrophysiology remains unclear. Thirty-three mongrel dogs were included in the present study. Renal sympathetic denervation was performed by radiofrequency ablation of the adventitial surface of the renal artery. In group 1 (n = 8), programmed stimulation was performed before and after RSD to determine the ventricular effective refractory period (ERP) and action potential duration (APD) restitution properties. The same parameters were measured in five other animals that underwent sham RSD to serve as controls. In group 2 (n = 10), acute myocardial ischaemia (AMI) was induced by ligating the proximal left anterior descending coronary artery after the performance of RSD, and the incidence of ventricular arrhythmia (VA) was calculated during 1 h of recording. In another 10 dogs (group 3), AMI was induced and VA was measured with sham RSD. In group 1, RSD significantly prolonged ventricular ERP and APD, reduced the maximal slope (Smax) of the restitution curve and suppressed APD alternans at each site. Renal sympathetic denervation also significantly decreased the spatial dispersion of ERP, APD and Smax. In the five control animals, no significant electrophysiological change was detected after sham RSD. The occurrence of spontaneous VA during 1 h of AMI in group 2 was significantly lower than that in group 3. These data suggest that RSD stabilizes ventricular electrophysiological properties in normal hearts and reduces the occurrence of VA in hearts experiencing AMI. © 2014 The Authors. Experimental Physiology © 2014 The Physiological Society.
Wohleb, Eric S; McKim, Daniel B; Shea, Daniel T; Powell, Nicole D; Tarr, Andrew J; Sheridan, John F; Godbout, Jonathan P
2014-06-15
Persistent anxiety-like symptoms may have an inflammatory-related pathophysiology. Our previous work using repeated social defeat (RSD) in mice showed that recruitment of peripheral myeloid cells to the brain is required for the development of anxiety. Here, we aimed to determine if 1) RSD promotes prolonged anxiety through redistribution of myeloid cells and 2) prior exposure to RSD sensitizes the neuroimmune axis to secondary subthreshold stress. Mice were subjected to RSD and several immune and behavioral parameters were determined .5, 8, or 24 days later. In follow-up studies, control and RSD mice were subjected to subthreshold stress at 24 days. Repeated social defeat-induced macrophage recruitment to the brain corresponded with development and maintenance of anxiety-like behavior 8 days after RSD, but neither remained at 24 days. Nonetheless, social avoidance and an elevated neuroinflammatory profile were maintained at 24 days. Subthreshold social defeat in RSD-sensitized mice increased peripheral macrophage trafficking to the brain that promoted re-establishment of anxiety. Moreover, subthreshold social defeat increased social avoidance in RSD-sensitized mice compared with naïve mice. Stress-induced monocyte trafficking was linked to redistribution of myeloid progenitor cells in the spleen. Splenectomy before subthreshold stress attenuated macrophage recruitment to the brain and prevented anxiety-like behavior in RSD-sensitized mice. These data indicate that monocyte trafficking from the spleen to the brain contributes re-establishment of anxiety in stress-sensitized mice. These findings show that neuroinflammatory mechanisms promote mood disturbances following stress-sensitization and outline novel neuroimmune interactions that underlie recurring anxiety disorders such as posttraumatic stress disorder. Copyright © 2014 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Ultrasound-assisted extraction of amino acids from grapes.
Carrera, Ceferino; Ruiz-Rodríguez, Ana; Palma, Miguel; Barroso, Carmelo G
2015-01-01
Recent cultivar techniques on vineyards can have a marked influence on the final nitrogen content of grapes, specifically individual amino acid contents. Furthermore, individual amino acid contents in grapes are related to the final aromatic composition of wines. A new ultrasound-assisted method for the extraction of amino acids from grapes has been developed. Several extraction variables, including solvent (water/ethanol mixtures), solvent pH (2-7), temperature (10-70°C), ultrasonic power (20-70%) and ultrasonic frequency (0.2-1.0s(-)(1)), were optimized to guarantee full recovery of the amino acids from grapes. An experimental design was employed to optimize the extraction parameters. The surface response methodology was used to evaluate the effects of the extraction variables. The analytical properties of the new method were established, including limit of detection (average value 1.4mmolkg(-)(1)), limit of quantification (average value 2.6mmolkg(-)(1)), repeatability (average RSD=12.9%) and reproducibility (average RSD=15.7%). Finally, the new method was applied to three cultivars of white grape throughout the ripening period. Copyright © 2014 Elsevier B.V. All rights reserved.
Hou, Xiao-Lin; Chen, Guo; Zhu, Li; Yang, Ting; Zhao, Jian; Wang, Lei; Wu, Yin-Liang
2014-07-01
A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk. Copyright © 2014 Elsevier B.V. All rights reserved.
Ilag, Leopold L; Westblade, Lars F; Deshayes, Caroline; Kolb, Annie; Busby, Stephen J W; Robinson, Carol V
2004-02-01
The E. coli RNA polymerase core enzyme is a multisubunit complex of 388,981 Da. To initiate transcription at promoters, the core enzyme associates with a sigma subunit to form holo RNA polymerase. Here we have used nanoflow electrospray mass spectrometry, coupled with tandem mass spectrometry, to probe the interaction of the RNA polymerase core enzyme with the most abundant sigma factor, sigma70. The results show remarkably well-resolved spectra for both the core and holo RNA polymerases. The regulator of sigma70, Rsd protein, has previously been identified as a protein that binds to free sigma70. We show that Rsd also interacts with core enzyme. In addition, by adding increasing amounts of Rsd, we show that sigma70 is displaced from holo RNA polymerase, resulting in complexes of Rsd with core and sigma70. The results argue for a model in which Rsd not only sequesters sigma70, but is also an effector of core RNA polymerase.
Pisanello, Francesca; Marziali, Laura; Rosignoli, Federica; Poma, Giulia; Roscioli, Claudio; Pozzoni, Fiorenzo; Guzzella, Licia
2016-06-01
DDT and mercury (Hg) contamination in the Toce River (Northern Italy) was caused by a factory producing technical DDT and using a mercury-cell chlor-alkali plant. In this study, DDT and Hg contamination and bioavailability were assessed by using different approaches: (1) direct evaluation of sediment contamination, (2) assessment of bioaccumulation in native benthic invertebrates belonging to different taxonomic/functional groups, and (3) evaluation of the in situ bioavailability of DDT and Hg using passive samplers. Sampling sites were selected upstream and downstream the industrial plant along the river axis. Benthic invertebrates (Gammaridae, Heptageniidae, and Diptera) and sediments were collected in three seasons and analyzed for DDT and Hg content and the results were used to calculate the biota sediment accumulation factor (BSAF). Polyethylene passive samplers (PEs) for DDT and diffusive gradients in thin films (DGTs) for Hg were deployed in sediments to estimate the concentration of the toxicants in pore water. Analysis for (DDx) were performed using GC-MS. Accuracy was within ±30 % of the certified values and precision was >20 % relative standard deviation (RSD). Total mercury concentrations were determined using an automated Hg mercury analyzer. Precision was >5 % and accuracy was within ±10 % of certified values. The results of all the approaches (analysis of sediment, biota, and passive samplers) showed an increasing contamination from upstream to downstream sites. BSAF values revealed the bioavailability of both contaminants in the study sites, with values up to 49 for DDx and up to 3.1 for Hg. No correlation was found between values in sediments and the organisms. Concentrations calculated using passive samplers were correlated with values in benthic invertebrates, while no correlation was found with concentrations in sediments. Thus, direct analysis of toxicant in sediments does not provide a measurement of bioavailability. On the contrary, analysis of bioaccumulation in benthic organisms provides the most realistic picture of the site-specific bioavailability of DDx and Hg, but this approach is time-consuming and not always feasible. On the other hand, the in situ deployment of passive samplers proved to be a powerful tool, providing a good surrogate measure of bioaccumulation.
HPr antagonizes the anti-σ70 activity of Rsd in Escherichia coli.
Park, Young-Ha; Lee, Chang-Ro; Choe, Mangyu; Seok, Yeong-Jae
2013-12-24
The bacterial phosphoenolpyruvate:sugar phosphotransferase system (PTS) is a multicomponent system that participates in a variety of physiological processes in addition to the phosphorylation-coupled transport of numerous sugars. In Escherichia coli and other enteric bacteria, enzyme IIA(Glc) (EIIA(Glc)) is known as the central processing unit of carbon metabolism and plays multiple roles, including regulation of adenylyl cyclase, the fermentation/respiration switch protein FrsA, glycerol kinase, and several non-PTS transporters, whereas the only known regulatory role of the E. coli histidine-containing phosphocarrier protein HPr is in the activation of glycogen phosphorylase. Because HPr is known to be more abundant than EIIA(Glc) in enteric bacteria, we assumed that there might be more regulatory mechanisms connected with HPr. The ligand fishing experiment in this study identified Rsd, an anti-sigma factor known to complex with σ(70) in stationary-phase cells, as an HPr-binding protein in E. coli. Only the dephosphorylated form of HPr formed a tight complex with Rsd and thereby inhibited complex formation between Rsd and σ(70). Dephosphorylated HPr, but not phosphorylated HPr, antagonized the inhibitory effect of Rsd on σ(70)-dependent transcriptions both in vivo and in vitro, and also influenced the competition between σ(70) and σ(S) for core RNA polymerase in the presence of Rsd. Based on these data, we propose that the anti-σ(70) activity of Rsd is regulated by the phosphorylation state-dependent interaction of HPr with Rsd.
Imipramine attenuates neuroinflammatory signaling and reverses stress-induced social avoidance.
Ramirez, Karol; Shea, Daniel T; McKim, Daniel B; Reader, Brenda F; Sheridan, John F
2015-05-01
Psychosocial stress is associated with altered immunity, anxiety and depression. Previously we showed that repeated social defeat (RSD) promoted microglia activation and social avoidance behavior that persisted for 24days after cessation of RSD. The aim of the present study was to determine if imipramine (a tricyclic antidepressant) would reverse RSD-inducedsocial avoidance and ameliorate neuroinflammatory responses. To test this, C57BL/6 mice were divided into treatment groups. One group from RSD and controls received daily injections of imipramine for 24days, following 6 cycles of RSD. Two other groups were treated with saline. RSD mice spent significantly less time in the interaction zone when an aggressor was present in the cage. Administration of imipramine reversed social avoidance behavior, significantly increasing the interaction time, so that it was similar to that of control mice. Moreover, 24days of imipramine treatment in RSD mice significantly decreased stress-induced mRNA levels for IL-6 in brain microglia. Following ex vivo LPS stimulation, microglia from mice exposed to RSD, had higher mRNA expression of IL-6, TNF-α, and IL-1β, and this was reversed by imipramine treatment. In a second experiment, imipramine was added to drinking water confirming the reversal of social avoidant behavior and decrease in mRNA expression of IL-6 in microglia. These data suggest that the antidepressant imipramine may exert its effect, in part, by down-regulating microglial activation. Copyright © 2015 Elsevier Inc. All rights reserved.
Complex regional pain syndrome type I (RSD): pathology of skeletal muscle and peripheral nerve.
van der Laan, L; ter Laak, H J; Gabreëls-Festen, A; Gabreëls, F; Goris, R J
1998-07-01
Reflex sympathetic dystrophy (RSD) (recently reclassified as complex regional pain syndrome type I) is a syndrome occurring in extremities and, when chronic, results in severe disability and untractable pain. RSD may be accompanied by neurologic symptoms even when there is no previous neurologic lesion. There is no consensus as to the pathogenic mechanism involved in RSD. To gain insight into the pathophysiology of RSD, we studied histopathology of skeletal muscle and peripheral nerve from patients with chronic RSD in a lower extremity. In eight patients with chronic RSD, an above-the-knee amputation was performed because of a nonfunctional limb. Specimens of sural nerves, tibial nerves, common peroneal nerves, gastrocnemius muscles, and soleus muscles were obtained from the amputated legs and analyzed by light and electron microscopy. In all patients, the affected leg showed similar neurologic symptoms such as spontaneous pain, hyperpathy, allodynia, paresis, and anesthesia dolorosa. The nerves showed no consistent abnormalities of myelinated fibers. In four patients, the C-fibers showed electron microscopic pathology. In all patients, the gastrocnemius and soleus muscle specimens showed a decrease of type I fibers, an increase of lipofuscin pigment, atrophic fibers, and severely thickened basal membrane layers of the capillaries. In chronic RSD, efferent nerve fibers were histologically unaffected; from afferent fibers, only C-fibers showed histopathologic abnormalities. Skeletal muscle showed a variety of histopathologic findings, which are similar to the histologic abnormalities found in muscles of patients with diabetes.
HPr antagonizes the anti-σ70 activity of Rsd in Escherichia coli
Park, Young-Ha; Lee, Chang-Ro; Choe, Mangyu; Seok, Yeong-Jae
2013-01-01
The bacterial phosphoenolpyruvate:sugar phosphotransferase system (PTS) is a multicomponent system that participates in a variety of physiological processes in addition to the phosphorylation-coupled transport of numerous sugars. In Escherichia coli and other enteric bacteria, enzyme IIAGlc (EIIAGlc) is known as the central processing unit of carbon metabolism and plays multiple roles, including regulation of adenylyl cyclase, the fermentation/respiration switch protein FrsA, glycerol kinase, and several non-PTS transporters, whereas the only known regulatory role of the E. coli histidine-containing phosphocarrier protein HPr is in the activation of glycogen phosphorylase. Because HPr is known to be more abundant than EIIAGlc in enteric bacteria, we assumed that there might be more regulatory mechanisms connected with HPr. The ligand fishing experiment in this study identified Rsd, an anti-sigma factor known to complex with σ70 in stationary-phase cells, as an HPr-binding protein in E. coli. Only the dephosphorylated form of HPr formed a tight complex with Rsd and thereby inhibited complex formation between Rsd and σ70. Dephosphorylated HPr, but not phosphorylated HPr, antagonized the inhibitory effect of Rsd on σ70-dependent transcriptions both in vivo and in vitro, and also influenced the competition between σ70 and σS for core RNA polymerase in the presence of Rsd. Based on these data, we propose that the anti-σ70 activity of Rsd is regulated by the phosphorylation state-dependent interaction of HPr with Rsd. PMID:24324139
Imipramine attenuates neuroinflammatory signaling and reverses stress-induced social avoidance
Ramirez, Karol; Shea, Daniel T.; McKim, Daniel B.; B.F., Reader; Sheridan, John F.
2015-01-01
Psychosocial stress is associated with altered immunity, anxiety and depression. Previously we showed that repeated social defeat (RSD) promoted microglia activation and social avoidance behavior that persisted for 24 days after cessation of RSD. The aim of the present study was to determine if imipramine (a tricyclic antidepressant) would reverse RSD-induced social avoidance and ameliorate neuroinflammatory responses. To test this, C57BL/6 mice were divided into treatment groups. One group from RSD and controls received daily injections of imipramine for 24 days, following 6 cycles of RSD. Two other groups were treated with saline. RSD mice spent significantly less time in the interaction zone when an aggressor was present in the cage. Administration of imipramine reversed social avoidance behavior, significantly increasing the interaction time, so that it was similar to that of control mice. Moreover, 24 days of imipramine treatment in RSD mice significantly decreased stress-induced mRNA levels for IL-6 in brain microglia. Following ex vivo LPS stimulation, microglia from mice exposed to RSD, had higher mRNA expression of IL-6, TNF-α, and IL-1β, and this was reversed by imipramine treatment. In a second experiment, imipramine was added to drinking water confirming the reversal of social avoidant behavior and decrease in mRNA expression of IL-6 in microglia. These data suggest that the antidepressant imipramine may exert its effect, in part, by down-regulating microglial activation. PMID:25701613
Modelling the large-scale redshift-space 3-point correlation function of galaxies
NASA Astrophysics Data System (ADS)
Slepian, Zachary; Eisenstein, Daniel J.
2017-08-01
We present a configuration-space model of the large-scale galaxy 3-point correlation function (3PCF) based on leading-order perturbation theory and including redshift-space distortions (RSD). This model should be useful in extracting distance-scale information from the 3PCF via the baryon acoustic oscillation method. We include the first redshift-space treatment of biasing by the baryon-dark matter relative velocity. Overall, on large scales the effect of RSD is primarily a renormalization of the 3PCF that is roughly independent of both physical scale and triangle opening angle; for our adopted Ωm and bias values, the rescaling is a factor of ˜1.8. We also present an efficient scheme for computing 3PCF predictions from our model, important for allowing fast exploration of the space of cosmological parameters in future analyses.
Ultra low-level measurements of actinides by sector field ICP-MS.
Pointurier, F; Baglan, N; Hémet, P
2004-01-01
In the present work, a double-focusing sector field inductively coupled plasma-mass spectrometer was optimised for ultra trace and isotopic analyses of actinide long-lived isotopes in low concentration solutions of the fgml(-1) to the ngml(-1) range. Sensitivities of about 3GHz/(microgml(-1)), with as low a background as 0.1cps, were obtained for U using a conventional concentric pneumatic nebuliser. Detection limits are below the fg range for 239Pu and 240Pu. With natural U, a precision lower than 0.5% RSD is currently obtained for 235U/238U isotopic ratio at the 200pgml(-1) level.
Krzek, Jan; Piotrowska, Joanna
2011-01-01
A fast spectrophotometric method has been developed for bacitracin identification and determination after condensation reaction with dabsyl chloride. In addition, determination of dye stability of sulfonamide derivative and identification of the molar ratio of reagents was done at various time-points. The developed method has a good linearity with very broad spectrum, correlation coefficient of r = 0.9972, good precision (RSD = 1.54 +/- 0.11%), and recovery at three different levels of concentration was found between 98.33% and 103.47%. Usefulness of the method was demonstrated by positive results obtained during determination of bacitracin concentration in bulk drug.
Determination of the Cryolite Ratio of KF-NaF-AlF3 Electrolyte by Conductivity Method
NASA Astrophysics Data System (ADS)
Yan, Hengwei; Yang, Jianhong; Liu, Zhanwei; Wang, Chengzhi; Ma, Wenhui
2018-05-01
The cryolite ratio (CR) is an important parameter for the electrolyte in aluminum reduction cells. The measurement method for the CR of the KF-NaF-AlF3 system acid (CR < 3) electrolyte by means of electrical conductivity was initially developed, and the formula for calculating the CR was deduced. This method has the advantages of simple operation and high precision. In addition, the relative standard deviations (RSD) of the measurement are < 1.2 pct, and the analysis error of the NaF or KF content has little effect on the determination of the CR.
NASA Astrophysics Data System (ADS)
Seela, Balaji Kumar; Janapati, Jayalakshmi; Lin, Pay-Liam; Reddy, K. Krishna; Shirooka, Ryuichi; Wang, Pao K.
2017-11-01
Raindrop size distribution (RSD) characteristics in summer season rainfall of two observational sites (Taiwan (24°58'N, 121°10'E) and Palau (7°20'N, 134°28'E)) in western Pacific are studied by using five years of impact type disdrometer data. In addition to disdrometer data, Tropical Rainfall Measuring Mission, Moderate Resolution Imaging Spectroradiometer, and ERA-Interim data sets are used to illustrate the dynamical and microphysical characteristics associated with summer season rainfall of Taiwan and Palau. Taiwan and Palau's raindrop spectra showed a significant difference, with a higher concentration of middle and large drops in Taiwan than Palau rainfall. RSD stratified on the basis of rain rate showed a higher mass-weighted mean diameter (Dm) and a lower normalized intercept parameter (log10Nw) in Taiwan than Palau rainfall. Precipitation classification into stratiform and convective regimes showed higher Dm values in Taiwan than Palau. Furthermore, for both the locations, the convective precipitation has a higher Dm value than stratiform precipitation. The radar reflectivity-rain rate relations (Z = A*Rb) of Taiwan and Palau showed a clear variation in the coefficient and a less variation in exponent values. Terrain-influenced clouds extended to higher altitudes over Taiwan resulted with higher Dm and lower log10Nw values as compared to Palau.
Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples.
Artigues, Margalida; Abellà, Jordi; Colominas, Sergi
2017-11-14
Amperometric biosensors based on the use of glucose oxidase (GOx) are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan) onto highly ordered titanium dioxide nanotube arrays (TiO₂NTAs) has been evaluated. The GOx-Chitosan/TiO₂NTAs biosensor showed a sensitivity of 5.46 μA·mM -1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%), reproducibility (RSD = 2.5%), accuracy (95-105% recovery), and robustness (RSD = 3.3%). Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx-Chitosan/TiO₂NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated.
Imae, Rieko; Dejima, Katsufumi; Kage-Nakadai, Eriko; Arai, Hiroyuki; Mitani, Shohei
2016-01-01
RNA silencing signals in C. elegans spread among cells, leading to RNAi throughout the body. During systemic spread of RNAi, membrane trafficking is thought to play important roles. Here, we show that RNAi Spreading Defective-3 (rsd-3), which encodes a homolog of epsinR, a conserved ENTH (epsin N-terminal homology) domain protein, generally participates in cellular uptake of silencing RNA. RSD-3 is previously thought to be involved in systemic RNAi only in germ cells, but we isolated several deletion alleles of rsd-3, and found that these mutants are defective in the spread of silencing RNA not only into germ cells but also into somatic cells. RSD-3 is ubiquitously expressed, and intracellularly localized to the trans-Golgi network (TGN) and endosomes. Tissue-specific rescue experiments indicate that RSD-3 is required for importing silencing RNA into cells rather than exporting from cells. Structure/function analysis showed that the ENTH domain alone is sufficient, and membrane association of the ENTH domain is required, for RSD-3 function in systemic RNAi. Our results suggest that endomembrane trafficking through the TGN and endosomes generally plays an important role in cellular uptake of silencing RNA. PMID:27306325
Imae, Rieko; Dejima, Katsufumi; Kage-Nakadai, Eriko; Arai, Hiroyuki; Mitani, Shohei
2016-06-16
RNA silencing signals in C. elegans spread among cells, leading to RNAi throughout the body. During systemic spread of RNAi, membrane trafficking is thought to play important roles. Here, we show that RNAi Spreading Defective-3 (rsd-3), which encodes a homolog of epsinR, a conserved ENTH (epsin N-terminal homology) domain protein, generally participates in cellular uptake of silencing RNA. RSD-3 is previously thought to be involved in systemic RNAi only in germ cells, but we isolated several deletion alleles of rsd-3, and found that these mutants are defective in the spread of silencing RNA not only into germ cells but also into somatic cells. RSD-3 is ubiquitously expressed, and intracellularly localized to the trans-Golgi network (TGN) and endosomes. Tissue-specific rescue experiments indicate that RSD-3 is required for importing silencing RNA into cells rather than exporting from cells. Structure/function analysis showed that the ENTH domain alone is sufficient, and membrane association of the ENTH domain is required, for RSD-3 function in systemic RNAi. Our results suggest that endomembrane trafficking through the TGN and endosomes generally plays an important role in cellular uptake of silencing RNA.
Hu, Wei; Zhao, Qing-yan; Yu, Sheng-bo; Sun, Bin; Chen, Liao; Cao, Sheng; Guo, Rui-qiang
2014-11-22
The purpose of this study was to investigate whether transcatheter renal sympathetic denervation (RSD) interfere with the development of left ventricular (LV) mechanical dyssynchrony during the progression of heart failure (HF). Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (seven dogs), and RSD group (six dogs). Sham-operated group were implanted with pacemakers without pacing; Control group were implanted with pacemakers and underwent 3 weeks of rapid right ventricular pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Both LV strain and LV dyssynchrony were analyzed via 2D speckle-tracking strain echocardiography to evaluate LV function. Longitudinal dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain on apical 4- and 2-chamber views. Radial and circumferential dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain in mid- and base-LV short-axis views. Each myocardial function was also evaluated by averaging the peak systolic strains. LV systolic pressure (LVSP) and LV end-diastolic pressure (LVEDP) were measured. The LV interstitial fibrosis was determined by histological analysis. Plasma angiotensin II (Ang II), aldosterone and norepinephrine (NE) levels were also measured. After 3 weeks, all of the dogs in both the control and RSD groups showed greater LV end-diastolic volume compared with the sham-operated group; however, the dogs in the RSD group had a higher LV ejection fraction (LVEF) than the dogs in the control group (p<0.001). The LV systolic strains were higher in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial strain, respectively). The levels of LV dyssynchrony were lower in the RSD group than in the control group (p<0.001 for longitudinal, circumferential and radial dyssynchrony, respectively). Compared with dogs with control alone, RSD dogs had lower LV end-diastolic pressures and less fibrous tissue. The levels of plasma Ang II, aldosterone and NE were lower in the RSD group than in the control group. RSD inhibites the development of left ventricular mechanical dyssynchrony during the progression of heart failure in dogs.
Watson, Lynn; Potter, Ross; Murphy, Cory; Gibbs, Ryan
2015-01-01
Due to potential use in aquacultured fish products, the Canadian Food Inspection Agency has identified residue testing for steroids as a priority. These compounds are used in aquaculture primarily to direct sexual differentiation with both androgens and estrogens applied depending on the desired outcome. Published research is lacking with respect to steroid residue testing in fish; however, recent studies in other matrixes provided transferable cleanup techniques. A simple, rapid, and sensitive method was developed and validated for use in monitoring aquacultured fish products for the presence of methyltestosterone, nandrolone, epi-nandrolone, boldenone, and epi-boldenone residues. The developed method consists of solvent extraction followed by cleanup using hexane and dual cartridge SPE with analysis by ultra-HPLC-MS/MS. The method is capable of detecting and confirming steroid residue levels ranging from 0.05 to 25 ng/g in salmon and tilapia, depending on the analyte. Recoveries ranged from 88 to 130% for the analytes. Instrument repeatability was less than 13% for all compounds, while intermediate precision ranged from 5 to 25% RSD. HorRat values were within acceptable ranges.
Leal, L O; Elsholz, O; Forteza, R; Cerdà, V
2006-07-28
A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas-liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas-liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50-5000 ng L(-1). The detection limit (3sigma(b)/S) achieved is 5 ng L(-1). The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L(-1) Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples.
Jain, Nilu; Jain, Gaurav Kumar; Ahmad, Farhan Jalees; Khar, Roop Krishen
2007-09-19
A simple, stability-indicating high-performance thin-layer liquid chromatographic (HPTLC) method for analysis of minocycline was developed and validated. The densitometric analysis was carried out at 345 nm using methanol-acetonitrile-isopropyl alcohol-water (5:4:0.5:0.5, v/v/v/v) as mobile phase. The method employed TLC aluminium plates pre-coated with silica gel 60F-254 as the stationary phase. To achieve good result, plates were sprayed with a 10% (w/v) solution of disodium ethylene diaminetetraacetic acid (EDTA), the pH of which was adjusted to 9.0. Compact spots of minocycline were found at R(f) = 0.30+/-0.02. For proposed procedure, linearity (r = 0.9997), limit of detection (3.7 ng spot(-1)), recovery (99.23-100.16%), and precision (% R.S.D. < or = 0.364) was found to be satisfactory. The drug undergoes acidic and basic degradation, oxidation and photodegradation. All the peaks of degradation products were well resolved from the pure drug with significantly different R(f) values. The acidic and alkaline degradation kinetics of minocycline, evaluated using this method, is found to be of first order.
Validated flow-injection method for rapid aluminium determination in anti-perspirants.
López-Gonzálvez, A; Ruiz, M A; Barbas, C
2008-09-29
A flow-injection (FI) method for the rapid determination of aluminium in anti-perspirants has been developed. The method is based on the spectrophotometric detection at 535nm of the complex formed between Al ions and the chromogenic reagent eriochrome cyanine R. Both the batch and FI methods were validated by checking the parameters included in the ISO-3543-1 regulation. Variables involved in the FI method were optimized by using appropriate statistical tools. The method does not exhibit interference from other substances present in anti-perspirants and it shows a high precision with a R.S.D. value (n=6) of 0.9%. Moreover, the accuracy of the method was evaluated by comparison with a back complexometric titration method, which is currently used for routine analysis in pharmaceutical laboratories. The Student's t-test showed that the results obtained by both methods were not significantly different for a significance level of 95%. A response time of 12s and a sample analysis time, by performing triplicate injections, of 60s were achieved. The analytical figures of merit make the method highly appropriate to substitute the time-consuming complexometric method for this kind of analysis.
Guo, Hongyue; Riter, Leah S; Wujcik, Chad E; Armstrong, Daniel W
2016-04-22
A novel method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed for the sensitive determination of glyphosate and its major degradation product, AMPA in environmental water samples. The method involves the use of MS compatible mobile phases (0.1% formic acid in water and acetonitrile) for HPLC and direct analysis of water samples without sample derivatization. The method has been validated in different types of water matrices (drinking, surface and groundwater) by accuracy and precision studies with samples spiked at 0.1, 7.5 and 90 ppb. All mean accuracy values ranged from 85% to 112% for glyphosate and AMPA using both primary and secondary quantitative ion transitions (RSD ≤ 10%). Moreover, both primary and secondary ion transitions for glyphosate and AMPA can achieve the quantitation limits at 0.1 ppb. The linear dynamic range of the calibration curves were from 0.1 to 100 ppb for each analyte at each ion transitions with correlation coefficient higher than 0.997. Copyright © 2016 Elsevier B.V. All rights reserved.
Cancho, B; Ventur, F; Galceran, M
2000-11-03
A headspace solid-phase microextraction (HS-SPME) procedure has been developed and applied for the determination of cyanogen halides in treated water samples at microg/L concentrations. Several SPME coatings were tested, the divinylbenzene-Carboxen-polydimethylsiloxane fiber being the most appropriate coating. GC-electron-capture detection was used for separation and quantitation. Experimental parameters such as sample volume, addition of a salt, extraction time and desorption conditions were studied. The optimized method has an acceptable linearity, good precision, with RSD values <10% for both compounds, and it is sufficiently sensitive to detect ng/L levels. HS-SPME was compared with liquid-liquid microextraction (US Environmental Protection Agency Method 551.1) for the analysis of spiked ultrapure and granular activated carbon filtered water samples. There was good agreement between the results from both methods. Finally, the optimized procedure was applied to determine both compounds at the Barcelona water treatment plant (N.E. Spain). Cyanogen chloride in treated water was <1.0 microg/L and cyanogen bromide ranged from 3.2 to 6.4 microg/L.
Zhao, Longshan; Zheng, Shuning; Su, Guangyue; Lu, Xiumei; Yang, Jingyu; Xiong, Zhili; Wu, Chunfu
2015-04-15
A sensitive and versatile, ultra-high performance, liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method coupled to pre-column derivatization for the simultaneous determination of 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA), dopamine (DA), norepinephrine (NE), homovanillic acid (HVA), γ-aminobutyric acid (GABA) and glutamic acid (Glu) was developed and validated in rat plasma. The analytes were dansylated under strong alkaline conditions after protein precipitation extraction, which were analyzed on a BEH C18 column using a gradient elution. The lower limit of quantification (LLOQ) values for 5-HT, 5-HIAA, DA, NE, HVA, GABA and Glu were 1.00, 1.00, 0.991, 0.992, 1.02, 1000, and 5030 pmol/mL, respectively. Good linearity was obtained (r > 0.99) and the intra- and inter-day precisions of the method (relative standard deviation, RSD%) were lower than 12%. The method was novel, sensitive and specific which can provide an alternative method for the quantification of neurotransmitters and their metabolites in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Sajid, Muhammad; Basheer, Chanbasha; Daud, Muhammad; Alsharaa, Abdulnaser
2017-03-17
In this work, the potential of layered double hydroxide/graphene (LDH-G) hybrid as a sorbent for extraction and preconcentration of fifteen organochlorine pesticides (OCPs) in urine samples was evaluated. The LDH-G hybrid was synthesized by co-precipitation method and it was then characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy and X-ray diffraction. The sorbent was then employed in membrane-protected stir-bar supported micro-solid-phase extraction (SB-μ-SPE) of OCPs in urine samples. This extraction approach is highly suitable for the samples representing matrix complexity such as urine because the sorbent is effectively protected inside the membrane. The extracted samples were analyzed by gas chromatography mass spectrometry. The factors that affect the performance of SB-μ-SPE were suitably optimized. This method demonstrated good linearity with coefficients of determination up to 0.9996. The limits of detection ranged between 0.22 and 1.38ngmL -1 . The RSD values for intra and inter-day precision were also in a satisfactory range (2.7-9.5%). Copyright © 2017 Elsevier B.V. All rights reserved.
Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M
2016-07-22
A rapid and sensitive procedure for the determination of six NPs in soils by gas chromatography and mass spectrometry (GC-MS) is proposed. Ultrasound assisted extraction (UAE) is used for NP extraction from soil matrices to an organic solvent, while the environmentally friendly technique dispersive liquid-liquid microextraction (DLLME) is used for the preconcentration of the resulting UAE extracts. NPs were derivatized by applying an "in-situ" acetylation procedure, before being injected into the GC-MS system using microvial insert large volume injection (LVI). Several parameters affecting UAE, DLLME, derivatization and injection steps were investigated. The optimized procedure provided recoveries of 86-111% from spiked samples. Precision values of the procedure (expressed as relative standard deviation, RSD) lower than 12%, and limits of quantification ranging from 1.3 to 2.6ngg(-1), depending on the compound, were obtained. Twenty soil samples, obtained from military, industrial and agricultural areas, were analyzed by the proposed method. Two of the analytes were quantified in two of the samples obtained from industrial areas, at concentrations in the 4.8-9.6ngg(-1) range. Copyright © 2016 Elsevier B.V. All rights reserved.
Suba, Dávid; Urbányi, Zoltán; Salgó, András
2016-10-01
Capillary electrophoresis techniques are widely used in the analytical biotechnology. Different electrophoretic techniques are very adequate tools to monitor size-and charge heterogenities of protein drugs. Method descriptions and development studies of capillary zone electrophoresis (CZE) have been described in literature. Most of them are performed based on the classical one-factor-at-time (OFAT) approach. In this study a very simple method development approach is described for capillary zone electrophoresis: a "two-phase-four-step" approach is introduced which allows a rapid, iterative method development process and can be a good platform for CZE method. In every step the current analytical target profile and an appropriate control strategy were established to monitor the current stage of development. A very good platform was established to investigate intact and digested protein samples. Commercially available monoclonal antibody was chosen as model protein for the method development study. The CZE method was qualificated after the development process and the results were presented. The analytical system stability was represented by the calculated RSD% value of area percentage and migration time of the selected peaks (<0.8% and <5%) during the intermediate precision investigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Płonka, Marlena; Walorczyk, Stanisław; Miszczyk, Marek; Kronenbach-Dylong, Dorota
2016-11-01
An analytical method for simultaneous determination of the active substance (chlorpyrifos) and its relevant impurity (sulfotep) in commercial pesticide formulations has been developed and validated. The proposed method entails extraction of the analytes from samples by sonication with acetone and analysis by gas chromatography-flame ionization detection (GC-FID). The proposed method was characterized by satisfactory accuracy and precision. The repeatability expressed as relative standard deviation (RSD) was lower than the acceptable values calculated from the modified Horwitz equation whereas individual recoveries were in the range of 98-102% and 80-120% for chlorpyrifos and sulfotep, respectively. The limit of quantification (LOQ) for the impurity (sulfotep) was 0.003 mg mL(-1) corresponding to the maximum permitted level according to Food and Agricultural Organization of the United Nations (FAO) specifications for the active substance (chlorpyrifos) being 3 g kg(-1) of the chlorpyrifos content found. The main advantage of the proposed method was a considerable reduction in the analysis time since both analytes were determined based on a single injection into the GC-FID. Analysis of real samples of commercial pesticide formulations confirmed fitness-for-purpose of the proposed method.
Robbins, Rebecca J; Leonczak, Jadwiga; Li, Julia; Johnson, J Christopher; Collins, Tom; Kwik-Uribe, Catherine; Schmitz, Harold H
2012-01-01
An international collaborative study was conducted on an HPLC method with fluorescent detection (FLD) for the determination of flavanols and procyanidins in materials containing chocolate and cocoa. The sum of the oligomeric fractions with degree of polymerization 1-10 was the determined content value. Sample materials included dark and milk chocolates, cocoa powder, cocoa liquors, and cocoa extracts. The content ranged from approximately 2 to 500 mg/g (defatted basis). Thirteen laboratories representing commercial, industrial, and academic institutions in six countries participated in the study. Fourteen samples were sent as blind duplicates to the collaborators. Results from 12 laboratories yielded repeatability relative standard deviation (RSDr) values that were below 10% for all materials analyzed, ranging from 4.17 to 9.61%. The reproducibility relative standard deviation (RSD(R)) values ranged from 5.03 to 12.9% for samples containing 8.07 to 484.7 mg/g. In one sample containing a low content of flavanols and procyanidins (approximately 2 mg/g), the RSD(R) was 17.68%. Based on these results, the method is recommended for Official First Action for the determination of flavanols and procyanidins in chocolate, cocoa liquors, powder(s), and cocoa extracts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun
Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less
Wohleb, Eric S; Powell, Nicole D; Godbout, Jonathan P; Sheridan, John F
2013-08-21
Social stress is associated with altered immunity and higher incidence of anxiety-related disorders. Repeated social defeat (RSD) is a murine stressor that primes peripheral myeloid cells, activates microglia, and induces anxiety-like behavior. Here we show that RSD-induced anxiety-like behavior corresponded with an exposure-dependent increase in circulating monocytes (CD11b(+)/SSC(lo)/Ly6C(hi)) and brain macrophages (CD11b(+)/SSC(lo)/CD45(hi)). Moreover, RSD-induced anxiety-like behavior corresponded with brain region-dependent cytokine and chemokine responses involved with myeloid cell recruitment. Next, LysM-GFP(+) and GFP(+) bone marrow (BM)-chimeric mice were used to determine the neuroanatomical distribution of peripheral myeloid cells recruited to the brain during RSD. LysM-GFP(+) mice showed that RSD increased recruitment of GFP(+) macrophages to the brain and increased their presence within the perivascular space (PVS). In addition, RSD promoted recruitment of GFP(+) macrophages into the PVS and parenchyma of the prefrontal cortex, amygdala, and hippocampus of GFP(+) BM-chimeric mice. Furthermore, mice deficient in chemokine receptors associated with monocyte trafficking [chemokine receptor-2 knockout (CCR2(KO)) or fractalkine receptor knockout (CX3CR1(KO))] failed to recruit macrophages to the brain and did not develop anxiety-like behavior following RSD. Last, RSD-induced macrophage trafficking was prevented in BM-chimeric mice generated with CCR2(KO) or CX3CR1(KO) donor cells. These findings indicate that monocyte recruitment to the brain in response to social stress represents a novel cellular mechanism that contributes to the development of anxiety.
Wohleb, Eric S.; Powell, Nicole D.
2013-01-01
Social stress is associated with altered immunity and higher incidence of anxiety-related disorders. Repeated social defeat (RSD) is a murine stressor that primes peripheral myeloid cells, activates microglia, and induces anxiety-like behavior. Here we show that RSD-induced anxiety-like behavior corresponded with an exposure-dependent increase in circulating monocytes (CD11b+/SSClo/Ly6Chi) and brain macrophages (CD11b+/SSClo/CD45hi). Moreover, RSD-induced anxiety-like behavior corresponded with brain region-dependent cytokine and chemokine responses involved with myeloid cell recruitment. Next, LysM-GFP+ and GFP+ bone marrow (BM)-chimeric mice were used to determine the neuroanatomical distribution of peripheral myeloid cells recruited to the brain during RSD. LysM-GFP+ mice showed that RSD increased recruitment of GFP+ macrophages to the brain and increased their presence within the perivascular space (PVS). In addition, RSD promoted recruitment of GFP+ macrophages into the PVS and parenchyma of the prefrontal cortex, amygdala, and hippocampus of GFP+ BM-chimeric mice. Furthermore, mice deficient in chemokine receptors associated with monocyte trafficking [chemokine receptor-2 knockout (CCR2KO) or fractalkine receptor knockout (CX3CR1KO)] failed to recruit macrophages to the brain and did not develop anxiety-like behavior following RSD. Last, RSD-induced macrophage trafficking was prevented in BM-chimeric mice generated with CCR2KO or CX3CR1KO donor cells. These findings indicate that monocyte recruitment to the brain in response to social stress represents a novel cellular mechanism that contributes to the development of anxiety. PMID:23966702
Post-Planck constraints on interacting vacuum energy
NASA Astrophysics Data System (ADS)
Wang, Yuting; Wands, David; Zhao, Gong-Bo; Xu, Lixin
2014-07-01
We present improved constraints on an interacting vacuum model using updated astronomical observations including the first data release from Planck. We consider a model with one dimensionless parameter, α, describing the interaction between dark matter and vacuum energy (with fixed equation of state w=-1). The background dynamics correspond to a generalized Chaplygin gas cosmology, but the perturbations have a zero sound speed. The tension between the value of the Hubble constant, H0, determined by Planck data plus WMAP polarization (Planck +WP) and that determined by the Hubble Space Telescope (HST) can be alleviated by energy transfer from dark matter to vacuum (α>0). A positive α increases the allowed values of H0 due to parameter degeneracy within the model using only cosmic microwave background data. Combining with additional data sets of including supernova type Ia (SN Ia) and baryon acoustic oscillation (BAO), we can significantly tighten the bounds on α. Redshift-space distortions (RSD), which constrain the linear growth of structure, provide the tightest constraints on vacuum interaction when combined with Planck+WP, and prefer energy transfer from vacuum to dark matter (α<0) which suppresses the growth of structure. Using the combined data sets of Planck +WP+Union2.1+BAO+RSD, we obtain the constraint on α to be -0.083<α<-0.006 (95% C.L.), allowing low H0 consistent with the measurement from 6dF Galaxy survey. This interacting vacuum model can alleviate the tension between RSD and Planck +WP in the ΛCDM model for α <0, or between HST measurements of H0 and Planck+WP for α>0, but not both at the same time.
USDA-ARS?s Scientific Manuscript database
Ratoon stunting disease (RSD), which is caused by the bacterium Leifsonia xyli subsp. xyli (Lxx), is now recognized worldwide as the most economically devastating disease impacting sugarcane. RSD causes significant yield losses and variety degradation. Diagnosis of RSD is challenging because it does...
USDA-ARS?s Scientific Manuscript database
Ratoon stunting disease (RSD) can decrease sugarcane yield by 5 to 15% if not properly managed. Currently, the disease is primarily managed by two approaches: breeding for RSD resistance and through sanitation, i.e., cleaning equipment and a clean seed program. Understanding the molecular basis of...
40 CFR 266.106 - Standards to control metals emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-specific doses (RSDs) are listed for the carcinogenic metals. The RSD for a metal is the acceptable ambient... RSD as described in paragraph (d)(3) of this section. (3) Carcinogenic metals. For the carcinogenic... person resides on site) to the risk-specific dose (RSD) for all carcinogenic metals emitted shall not...
40 CFR 266.106 - Standards to control metals emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-specific doses (RSDs) are listed for the carcinogenic metals. The RSD for a metal is the acceptable ambient... RSD as described in paragraph (d)(3) of this section. (3) Carcinogenic metals. For the carcinogenic... person resides on site) to the risk-specific dose (RSD) for all carcinogenic metals emitted shall not...
40 CFR 266.106 - Standards to control metals emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-specific doses (RSDs) are listed for the carcinogenic metals. The RSD for a metal is the acceptable ambient... RSD as described in paragraph (d)(3) of this section. (3) Carcinogenic metals. For the carcinogenic... person resides on site) to the risk-specific dose (RSD) for all carcinogenic metals emitted shall not...
Regulation of Global Transcription in Escherichia coli by Rsd and 6S RNA
Lal, Avantika; Krishna, Sandeep; Seshasayee, Aswin Sai Narain
2018-01-01
In Escherichia coli, the sigma factor σ70 directs RNA polymerase to transcribe growth-related genes, while σ38 directs transcription of stress response genes during stationary phase. Two molecules hypothesized to regulate RNA polymerase are the protein Rsd, which binds to σ70, and the non-coding 6S RNA which binds to the RNA polymerase-σ70 holoenzyme. Despite multiple studies, the functions of Rsd and 6S RNA remain controversial. Here we use RNA-Seq in five phases of growth to elucidate their function on a genome-wide scale. We show that Rsd and 6S RNA facilitate σ38 activity throughout bacterial growth, while 6S RNA also regulates widely different genes depending upon growth phase. We discover novel interactions between 6S RNA and Rsd and show widespread expression changes in a strain lacking both regulators. Finally, we present a mathematical model of transcription which highlights the crosstalk between Rsd and 6S RNA as a crucial factor in controlling sigma factor competition and global gene expression. PMID:29686109
Regulation of Global Transcription in Escherichia coli by Rsd and 6S RNA.
Lal, Avantika; Krishna, Sandeep; Seshasayee, Aswin Sai Narain
2018-05-31
In Escherichia coli , the sigma factor σ 70 directs RNA polymerase to transcribe growth-related genes, while σ 38 directs transcription of stress response genes during stationary phase. Two molecules hypothesized to regulate RNA polymerase are the protein Rsd, which binds to σ 70 , and the non-coding 6S RNA which binds to the RNA polymerase-σ 70 holoenzyme. Despite multiple studies, the functions of Rsd and 6S RNA remain controversial. Here we use RNA-Seq in five phases of growth to elucidate their function on a genome-wide scale. We show that Rsd and 6S RNA facilitate σ 38 activity throughout bacterial growth, while 6S RNA also regulates widely different genes depending upon growth phase. We discover novel interactions between 6S RNA and Rsd and show widespread expression changes in a strain lacking both regulators. Finally, we present a mathematical model of transcription which highlights the crosstalk between Rsd and 6S RNA as a crucial factor in controlling sigma factor competition and global gene expression. Copyright © 2018 Lal et al.
[Spectrophotometric determination of piroxicam using ferric ferricyanide as reagent].
Mândrescu, Mariana; Spac, A F; Dorneanu, V
2009-01-01
For the piroxicam determination (nonsteroidal antiinflammatory drug-NSAID) it was developed a spectrophotometric method, based on the reduction of ferric ferricyanide into ferro-ferricyanide (Prussian Blue), with maximum of absorbance at 760 nm. The practical working conditions were established. In the 0.2 divided by 2.0 microg/mL range of piroxicam concentration, were used the 2 mL of ferric ferricyanide 1 mL of 2N hydrocloric acid. To delay the flocculation of Prussian Blue it was to add a 1 mL solution of sodium lauryl sulfate 1%. After 15 minutes read the absorbance at 760 nm. The developed method was validated. The method showed a good linearity in the range of 0.2 divided by 2.0 microg/mL (the correlation coefficient r = 0.9995). The detection limit (LD) was 0.056 microg/mL and the quantification limit (LQ) was 0.18 microg/mL. There were established the system precision (RSD = 0.25%), the precison (RSD = 1.91%) and the accuracy-recovery in the range 98.21 divided by 104.92% with a mean recovery of 100.91%. The experimental results demonstrated a good sensibility. The specific absorptivity for this method is A(1 cm, 760 nm)(1%) = 4374 much higher than piroxicam in UV (A(1 cm, 330 nm)(1%) = 296)
Zhang, Xiaodan; Zhou, Xinqi; Liu, Xiangqian; Li, Xiaolong; Whang, Wankyunn
2016-01-01
Acanthopanax species are used in traditional medicine to treat numerous diseases. A simultaneous high-performance liquid chromatography (HPLC) method was developed and validated for the determination of the flavonoid and phenolic content of Acanthopanax leaves. HPLC analysis was performed on an AKZO NOBEL Kromasil 100-5C18 column (250 × 4.6 mm, 5 µm) using a gradient elution of acetonitrile–water containing 0.2% formic acid with a flow rate of 1.0 mL/min, monitored at 320 nm. The method was linear over the range 1–500 µg/mL (determination coefficients R2 > 0.999). Satisfactory intraday and interday precision was achieved, with the relative standard deviation (RSD) <2.99%. The mean recoveries measured at the three concentrations were in the range of 90.11–104.83%, with RSD <2.91% for the targets. Twenty-four samples of Acanthopanax leaves from different species and locations were examined using this analytical method, and their chemical profiles provided information for the chemotaxonomic investigation. The established method is simple, rapid and reliable for the quality control of Acanthopanax leaves of various species from different collections. The complete phenolic and flavonoid profiles of Acanthopanax leaves of various species have been established. PMID:26711585
Liu, Hao-Long; Luo, Rong; Chen, Xiao-Qing; Ba, Yin-Ying; Zheng, Li; Guo, Wei-Wei; Wu, Xia
2015-06-15
A simple, effective and suitable UFLC-ESI-MS/MS method was firstly developed to simultaneously determine five characteristic constituents (piperine, piperlonguminine, Δα,β-dihydropiperlonguminine, pellitorine and piperanine) of Piper longum L. The total alkaloids of P. longum L. was prepared. The alkaloid contents of Piper nigrum L. and P. longum L. were compared. The analysis was carried out in multiple reaction monitoring scan mode. The method showed a good specificity, linearity (R(2)>0.995), stability (RSD<2.53%), repeatability (RSD<2.58%), and recovery (90.0-103.5%). The limits of detection and limits of quantification of five alkaloids were in the range of 0.02-0.03 and 0.05-0.10 ng/mL, respectively. The intra- and inter-day precision was less than 9.30% and 9.55%, respectively. The validation results confirmed that the method could simultaneously determine the target alkaloids in the sample. Furthermore, the identities of the alkaloids were verified by HPLC-ESI-MS/MS. Compared with P. nigrum, P. longum had lower piperine content but was enriched in the other four alkaloids. Copyright © 2015 Elsevier Ltd. All rights reserved.
Herrington, Jason S
2013-08-20
The costly damage airborne trimethylsilanol (TMS) exacts on optics in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts per trillion, volume per volume of air [ppt(v)] [~ng/m(3)]). In this study I developed a whole air canister-based approach for field sampling trimethylsilanol in air, as well as a preconcentration gas chromatography/mass spectrometry laboratory method for analysis. The results demonstrate clean canister blanks (0.06 ppt(v) [0.24 ng/m(3)], which is below the detection limit), excellent linearity (a calibration relative response factor relative standard deviation [RSD] of 9.8%) over a wide dynamic mass range (1-100 ppt(v)), recovery/accuracy of 93%, a low selected ion monitoring method detection limit of 0.12 ppt(v) (0.48 ng/m(3)), replicate precision of 6.8% RSD, and stability (84% recovery) out to four days of storage at room temperature. Samples collected at two silicon wafer fabrication facilities ranged from 10.0 to 9120 ppt(v) TMS and appear to be associated with the use of hexamethyldisilazane priming agent. This method will enable semiconductor cleanroom managers to monitor and control for trace levels of trimethylsilanol.
Zhang, Yong; Huang, Xiaojia; Yuan, Dongxing
2015-01-01
A porous poly(methacrylic acid-co-ethylene dimethacrylate) monolithic fiber (MEMF) for solid-phase microextraction (SPME) of five benzimidazole anthelmintics was prepared by in-situ polymerization. The effect of polymerization conditions on SPME of the target analytes was studied thoroughly. The physicochemical properties of the monolith were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy, and mercury intrusion porosimetry. Several conditions affecting the extraction efficiency were investigated and, under the optimized conditions, a simple and sensitive method for the determination of trace benzimidazoles residues in milk and honey was established by coupling MEMF-SPME with high-performance liquid chromatography-diode array detection (MEMF-SPME-HPLC-DAD). Under the optimum experimental conditions, the limits of detection (S/N = 3) of the method were 0.11-0.30 μg L(-1) for milk and 0.086-0.28 μg L(-1) for honey. Evaluation of intra-day and inter-day precision showed reproducibility was satisfactory-relative standard deviations (RSD) for both were <10 %. Finally, the method was successfully used for determination of benzimidazole residues in milk and honey. Recoveries obtained for determination of benzimidazole anthelmintics in spiked samples ranged from 72.3 to 121 %, with RSD always <11 %.
Slot, Esther M; van Viersen, Sietske; de Bree, Elise H; Kroesbergen, Evelyn H
2016-01-01
High comorbidity rates have been reported between mathematical learning disabilities (MD) and reading and spelling disabilities (RSD). Research has identified skills related to math, such as number sense (NS) and visuospatial working memory (visuospatial WM), as well as to literacy, such as phonological awareness (PA), rapid automatized naming (RAN) and verbal short-term memory (Verbal STM). In order to explain the high comorbidity rates between MD and RSD, 7-11-year-old children were assessed on a range of cognitive abilities related to literacy (PA, RAN, Verbal STM) and mathematical ability (visuospatial WM, NS). The group of children consisted of typically developing (TD) children (n = 32), children with MD (n = 26), children with RSD (n = 29), and combined MD and RSD (n = 43). It was hypothesized that, in line with the multiple deficit view on learning disorders, at least one unique predictor for both MD and RSD and a possible shared cognitive risk factor would be found to account for the comorbidity between the symptom dimensions literacy and math. Secondly, our hypotheses were that (a) a probabilistic multi-factorial risk factor model would provide a better fit to the data than a deterministic single risk factor model and (b) that a shared risk factor model would provide a better fit than the specific multi-factorial model. All our hypotheses were confirmed. NS and visuospatial WM were identified as unique cognitive predictors for MD, whereas PA and RAN were both associated with RSD. Also, a shared risk factor model with PA as a cognitive predictor for both RSD and MD fitted the data best, indicating that MD and RSD might co-occur due to a shared underlying deficit in phonological processing. Possible explanations are discussed in the context of sample selection and composition. This study shows that different cognitive factors play a role in mathematics and literacy, and that a phonological processing deficit might play a role in the occurrence of MD and RSD.
NASA Astrophysics Data System (ADS)
Gatlin, P. N.; Thurai, M.; Petersen, W. A.; Bringi, V. N.
2017-12-01
As GPM facilitates precipitation estimation at higher latitudes where light rainfall is more common it becomes more important that we can fully describe the raindrop size distribution (RSD) across the continuum of observed raindrop sizes. An adequate understanding and the capability to represent the RSD in light rain and drizzle extends from GPM radar algorithms into radiometer-based algorithms, where auto-conversion from cloud to rainwater contents and size distributions becomes important for light rain/drizzle estimation. This study provides insights into the effect of small raindrops on our ability to accurately map rainfall. The RSD has been widely defined using a gamma distribution—the assumption often being verified and approach being reinforced using measurements that imperfectly measure the small end of the RSD. However, we find that the gamma model as it is applied in its current form, to include commonly used disdrometer measurements to define it, is not capable of accurately describing the small raindrops we have observed during light rainfall. We demonstrate the difficulty encountered at light rain rates (e.g., 0.5 mm/hr or less) and for drops typically < 0.6 - 0.7 mm in diameter using a disdrometer with a pixel resolution of 50 microns operated alongside a 2DVD, with both instruments inside a small DFIR wind fence. Measurements were made in two locations with different climates—Greely, Colorado and Huntsville, Alabama. The resultant comparison reveals that the gamma RSD model overestimates the characteristic raindrop diameter (Dm), especially for light rainfall. A generalized gamma distribution provides a closer fit to the RSD observations across the continuum of raindrop sizes and highlights a drizzle mode of the RSD exists that would otherwise not be described with the commonly used gamma RSD model. Our analysis also suggests that RSD-based separation of stratiform and convective rainfall requires special consideration for light rainfall cases, especially those with small mass-weighted mean diameters (Dm < 0.6 mm).
Sawicki, Caroline M; Kim, January K; Weber, Michael D; Jarrett, Brant L; Godbout, Jonathan P; Sheridan, John F; Humeidan, Michelle
2018-03-01
Mounting evidence indicates that stress influences the experience of pain. Exposure to psychosocial stress disrupts bi-directional communication pathways between the central nervous system and peripheral immune system, and can exacerbate the frequency and severity of pain experienced by stressed subjects. Repeated social defeat (RSD) is a murine model of psychosocial stress that recapitulates the immune and behavioral responses to stress observed in humans, including activation of stress-reactive neurocircuitry and increased pro-inflammatory cytokine production. It is unclear, however, how these stress-induced neuroimmune responses contribute to increased pain sensitivity in mice exposed to RSD. Here we used a technique of regional analgesia with local anesthetics in mice to block the development of mechanical allodynia during RSD. We next investigated the degree to which pain blockade altered stress-induced neuroimmune activation and depressive-like behavior. Following development of a mouse model of regional analgesia with discrete sensory blockade over the dorsal-caudal aspect of the spine, C57BL/6 mice were divided into experimental groups and treated with Ropivacaine (0.08%), Liposomal Bupivacaine (0.08%), or Vehicle (0.9% NaCl) prior to exposure to stress. This specific region was selected for analgesia because it is the most frequent location for aggression-associated pain due to biting during RSD. Mechanical allodynia was assessed 12 h after the first, third, and sixth day of RSD after resolution of the sensory blockade. In a separate experiment, social avoidance behavior was determined after the sixth day of RSD. Blood, bone marrow, brain, and spinal cord were collected for immunological analyses after the last day of RSD in both experiments following behavioral assessments. RSD increased mechanical allodynia in an exposure-dependent manner that persisted for at least one week following cessation of the stressor. Mice treated with either Ropivacaine or Liposomal Bupivacaine did not develop mechanical allodynia following exposure to stress, but did develop social avoidance behavior. Neither drug affected stress-induced activation of monocytes in the bone marrow, blood, or brain. Neuroinflammatory responses developed in all treatment groups, as evidenced by elevated IL-1β mRNA levels in the brain and spinal cord after RSD. In this study, psychosocial stress was associated with increased pain sensitivity in mice. Development of mechanical allodynia with RSD was blocked by regional analgesia with local anesthetics, Ropivacaine or Liposomal Bupivacaine. Despite blocking mechanical allodynia, these anesthetic interventions did not prevent neuroimmune activation or social avoidance associated with RSD. These data suggest that stress-induced neuroinflammatory changes are not associated with increased sensitivity to pain following RSD. Thus, blocking peripheral nociception was effective in inhibiting enhanced pain signaling without altering stress-induced immune or behavioral responses. Copyright © 2017 Elsevier Inc. All rights reserved.
2012-01-01
This study represents the first report on the development of a novel spectrophotometric method for determination of cinacalcet hydrochloride (CIN) in its tablet dosage forms. Studies were carried out to investigate the reaction between CIN and 1,2-naphthoquinone-4-sulphonate (NQS) reagent. In alkaline medium (pH 8.5), an orange red-colored product exhibiting maximum absorption peak (λmax) at 490 nm was produced. The stoichiometry and kinetic of the reaction were investigated and the reaction mechanism was postulated. This color-developing reaction was employed in the development of a simple and rapid visible-spectrophotometric method for determination of CIN in its tablets. Under the optimized reaction conditions, Beer's law correlating the absorbance with CIN concentration was obeyed in the range of 3 - 100 μg/ml with good correlation coefficient (0.9993). The molar absorptivity (ε) was 4.2 × 105 l/mol/cm. The limits of detection and quantification were 1.9 and 5.7 μg/ml, respectively. The precision of the method was satisfactory; the values of relative standard deviations (RSD) did not exceed 2%. No interference was observed from the excipients that are present in the tablets. The proposed method was applied successfully for the determination of CIN in its pharmaceutical tablets with good accuracy and precisions; the label claim percentage was 100.80 - 102.23 ± 1.27 - 1.62%. The results were compared favorably with those of a reference pre-validated method. The method is practical and valuable in terms of its routine application in quality control laboratories. PMID:22305461
Discipline for Students with Disabilities in the Recovery School District (RSD) of New Orleans
ERIC Educational Resources Information Center
Jeffers, Elizabeth K.
2014-01-01
This article focuses on special education in New Orleans post Hurricane Katrina. After Hurricane Katrina, Louisiana's Recovery School District (RSD) took over 102 of the city's 128 schools with the stated goal of creating a "choice district" for parents. This "choice distric"' is made up of RSD direct-run schools, Orleans…
van Brussel, Peter M; Eeftinck Schattenkerk, Daan W; Dobrowolski, Linn C; de Winter, Robbert J; Reekers, Jim A; Verberne, Hein J; Vogt, Liffert; van den Born, Bert-Jan H
2016-01-01
Renal sympathetic denervation (RSD) is currently being investigated in multiple studies of sympathetically driven cardiovascular diseases such as heart failure and arrhythmias. Our aim was to assess systemic and cardiac sympatholytic effects of RSD by the measurement of cardiac sympathetic activity and cardiovascular parameters. A total of 21 consecutive patients with refractory hypertension (daytime ambulatory blood pressure (BP)≥150/100 mmHg despite the use of 3 or more antihypertensive drugs), no evidence for secondary hypertension and normal renovascular anatomy were included. RSD was performed with the Medtronic Symplicity renal denervation catheter with an average of 4.2 (range 3-6) ablations per renal artery. To assess cardiac sympathetic activity, 123I-mIBG cardiac scintigraphy was performed before and 6 weeks after. In addition, the effect of RSD on peripheral BP and cardiac hemodynamics were assessed non-invasively. 123I-mIBG uptake before and after RSD was 1.7±0.4% vs. 1.7±0.5% at 15 min. and 1.4±0.4% vs. 1.5±0.5% after 4 h. As a consequence, washout rate was similar before (33.7±11.7%) and after RSD (30.1±12.6%, p=0.27). In line with earlier RSD studies, a significant drop in systolic office BP (-12.2 mmHg, p=0.04) was detected, whereas the decrease in ambulatory BP was not significant. No changes were seen in heart rate, stroke volume or left ventricular contractility, both in supine position and after standing. In concert with previous reports, RSD leads to a significant drop in office BP. However, a reduction in sympathetic activity could not be demonstrated on a cardiac level. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K
2017-09-01
Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Sun, Yichun; Xue, Juan; Li, Baimei; Lin, Xiaoting; Wang, Zhibin; Jiang, Hai; Zhang, Hongwei; Wang, Qiuhong; Kuang, Haixue
2016-11-01
A rapid, sensitive, and reliable analytical ultra performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of Aralia-saponin IV, 3-O-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl oleanolic acid 28-O-β-d-glucopyranoside, Aralia-saponin A and Aralia-saponin B after the oral administration of total saponin of Aralia elata leaves in rat plasma. Plasma samples were pretreated by protein precipitation with methanol. The analysis was performed on an ACQUITY UPLC HSS T3 column. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using an electrospray ionization source with negative ionization mode. Under the experimental conditions, the calibration curves of four analytes had good linearity values (r > 0.991). The intra- and inter-day precision values of the four analytes were ≤ 11.6%, and the accuracy was between -6.2 and 4.2%.The extraction recoveries of four triterpenoid saponins were in the range of 84.06-91.66% (RSD < 10.5%), and all values of the matrix effect were more than 90.30%. The developed analytical method was successfully applied to pharmacokinetic study on simultaneous determination of the four triterpenoid saponins in rat plasma after oral administration of total saponin of Aralia elata leaves, which helps guiding clinical usage of Aralia elata leaves. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won
2015-01-01
Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746
Kasiotis, Konstantinos M; Anagnostopoulos, Chris; Anastasiadou, Pelagia; Machera, Kyriaki
2014-07-01
The aim of this study was to investigate reported cases of honeybee death incidents with regard to the potential interrelation to the exposure to pesticides. Thus honeybee, bee pollen and honey samples from different areas of Greece were analyzed for the presence of pesticide residues. In this context an LC-ESI-MS/MS multiresidue method of total 115 analytes of different chemical classes such as neonicotinoids, organophosphates, triazoles, carbamates, dicarboximides and dinitroanilines in honeybee bodies, honey and bee pollen was developed and validated. The method presents good linearity over the ranges assayed with correlation coefficient values r(2)≥0.99, recoveries ranging for all matrices from 59 to 117% and precision (RSD%) values ranging from 4 to 27%. LOD and LOQ values ranged - for honeybees, honey and bee pollen - from 0.03 to 23.3 ng/g matrix weight and 0.1 up to 78 ng/g matrix weight, respectively. Therefore this method is sufficient to act as a monitoring tool for the determination of pesticide residues in cases of suspected honeybee poisoning incidents. From the analysis of the samples the presence of 14 active substances was observed in all matrices with concentrations ranging for honeybees from 0.3 to 81.5 ng/g, for bee pollen from 6.1 to 1273 ng/g and for honey one sample was positive to carbendazim at 1.6 ng/g. The latter confirmed the presence of such type of compounds in honeybee body and apicultural products. Copyright © 2014 Elsevier B.V. All rights reserved.
Ducher, J-L; Dalery, J
2008-04-01
Most of the people who will attempt suicide, talk about it beforehand. Therefore, recognition of suicidal risk is not absolutely impossible. Beck's suicidal ideation scale and Ducher's suicidal risk assessment scale (RSD) are common tools to help practicians in this way. These scales and the Hamilton's depression scale were included in an international multicentric, phase IV, double-blind study, according to two parallel groups who had been administered a fixed dose of fluvoxamin or fluoxetin for six weeks. This allowed examination of the correlations between these scales and the relations, which could possibly exist between suicidal risk, depression and anxiety. (a) Relationships between the Beck's suicidal ideation scale, the suicidal risk assessment scale RSD and Hamilton's depression before treatment. Before treatment, the analysis was conducted with 108 male and female depressive outpatients, aged 18 or over. Results revealed a significant positive correlation (with a Pearson's correlation coefficient r equal to 0.69 and risk p<0.0001) between Beck's suicidal ideation scale and the suicidal risk assessment scale RSD. These scales correlate less consistently with Hamilton's depression (Beck/Hamilton's depression: r=0.34; p=0.0004-RSD/Hamilton's depression: r=0.35; p=0.0002). We observed that the clinical anxiety scale by Snaith is also strongly correlated to these two suicidal risk assessment scales (Beck/CAS: r=0.48; p<0.0001-RSD/CAS: r=0.35; p=0.0005). Besides, the item "suicide" of Hamilton's depression scale accounts for more than a third of the variability of Beck's suicidal ideation scale and the suicidal risk assessment scale RSD. According to these results, the suicidal risk evaluated by these two scales seems to be significantly correlated with anxiety as much as with depression. On the other hand, the Clinical Global Impression is fairly significantly correlated with Beck's suicidal ideation scale (r=0.22; p=0.02), unlike the suicidal risk assessment scale RSD (r=0.42; p<0.0001) and Hamilton's depression scale (r=0.58; p<0.0001); (b) Relationships between Beck's suicidal ideation scale, the suicidal risk assessment scale RSD and Hamilton's depression under treatment. The follow-up under treatment (fluvoxamin or fluoxetin) during six weeks revealed the significantly better sensitivity of the RSD in comparison with Beck's suicidal ideation scale and Hamilton's depression scale, showing the significantly faster improvement in the RSD (p<0.0001). There was no significant difference between the evolution of Beck's suicidal ideation scale and Hamilton's depression scale. So, under treatment with fluvoxamin or fluoxetin, the improvement in suicidal risk appears to be as rapid as the improvement in depression. If we look at the treatment prescribed, only the suicidal risk assessment scale RSD revealed a significant difference between the two molecules, with more rapid improvement with fluvoxamin (p=0.015) from D14. In conclusion, the results of this study hypothesize that the suicidal risk, as assessed by Beck's suicidal ideation scale and the suicidal risk assessment scale RSD, appears to be consistently correlated with both the level of anxiety and depression. The study also suggests that all antidepressants may not be equally effective on suicidal risk.
Rajan, Sekar; Colaco, Socorrina; Ramesh, N; Meyyanathan, Subramania Nainar; Elango, K
2014-02-01
This study describes the development and validation of dissolution tests for sustained release Dextromethorphan hydrobromide tablets using an HPLC method. Chromatographic separation was achieved on a C18 column utilizing 0.5% triethylamine (pH 7.5) and acetonitrile in the ratio of 50:50. The detection wavelength was 280 nm. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The suitable conditions were clearly decided after testing sink conditions, dissolution medium and agitation intensity. The most excellent dissolution conditions tested, for the Dextromethorphan hydrobromide was applied to appraise the dissolution profiles. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The method was established to have sufficient intermediate precision as similar separation was achieved on another instrument handled by different operators. Mean Recovery was 101.82%. Intra precisions for three different concentrations were 1.23, 1.10 0.72 and 1.57, 1.69, 0.95 and inter run precisions were % RSD 0.83, 1.36 and 1.57%, respectively. The method was successfully applied for dissolution study of the developed Dextromethorphan hydrobromide tablets.
Malinsky, Michelle Duval; Jacoby, Cliffton B; Reagen, William K
2011-01-10
We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100±13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented. Copyright © 2010 Elsevier B.V. All rights reserved.
Attimarad, Mahesh
2010-01-01
The objective of this study was to develop simple, precise, accurate and sensitive UV spectrophotometric methods for the simultaneous determination of ofloxacin (OFX) and flavoxate HCl (FLX) in pharmaceutical formulations. The first method is based on absorption ratio method, by formation of Q absorbance equation at 289 nm (λmax of OFX) and 322.4 nm (isoabsorptive point). The linearity range was found to be 1 to 30 μg/ml for FLX and OFX. In the method-II second derivative absorption at 311.4 nm for OFX (zero crossing for FLX) and at 246.2 nm for FLX (zero crossing for OFX) was used for the determination of the drugs and the linearity range was found to be 2 to 30 μg/ml for OFX and 2-75 μg /ml for FLX. The accuracy and precision of the methods were determined and validated statistically. Both the methods showed good reproducibility and recovery with % RSD less than 1.5%. Both the methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of OFX and FLX in combined dosage form PMID:24826003
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, R.B.; Fiarman, S.; Jung, E.A.
1990-10-01
This paper is the final report on DOE-OSS Task ANLE88002 Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software andmore » discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software. Sample measurement time of less than 20 minutes was attained by pre-equilibration of the samples in low cost precision preheaters and by prediction of equilibrium measurements. Tests at the TA55 Plutonium Facility at Los Alamos National Laboratory, on typical samples, indicates that the instrument meets all the measurement requirements.« less
Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves.
Katekhaye, S; Kale, M S; Laddha, K S
2012-01-01
A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C(18) column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r(2)>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves.
Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves
Katekhaye, S; Kale, M. S.; Laddha, K. S.
2012-01-01
A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C18 column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r2>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves. PMID:23204626
Niopas, Ioannis; Daftsios, Athanasios C
2002-05-15
Glibenclamide is a potent second generation oral sulfonylurea antidiabetic agent widely used for the treatment of type II diabetes melitus. A rapid, sensitive, precise, accurate and specific HPLC assay for the determination of glibenclamide in human plasma was developed and validated. After addition of flufenamic acid as internal standard, the analytes were isolated from human plasma by liquid-liquid extraction. The method was linear in the 10-400 ng/ml concentration range (r > 0.999). Recovery for glibenclamide was greater than 91.5% and for internal standard was 93.5%. Within-day and between-day precision, expressed as the relative standard deviation (RSD%), ranged from 1.4 to 5.9% and 5.8 to 6.6%, respectively. Assay accuracy was better than 93.4%. The assay was used to estimate the pharmacokinetics of glibenclamide after oral administration of a 5 mg tablet of glibenclamide to 18 healthy volunteers.
Song, Yingshi; Yan, Huiyu; Xu, Jingbo; Ma, Hongxi
2017-09-01
A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid-liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0-1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra-day and inter-day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration. Copyright © 2017 John Wiley & Sons, Ltd.
Haghi, Ghasem; Arshi, Rohollah; Safaei, Alireza
2008-02-27
A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.
Zhan, Jia; Zhong, Ying-ying; Yu, Xue-jun; Peng, Jin-feng; Chen, Shubing; Yin, Ju-yi; Zhang, Jia-Jie; Zhu, Yan
2013-06-01
A rapid, simple and generic analytical method which was able to simultaneously determine 220 undesirable chemical residues in infant formula had been developed. The method comprised of extraction with acetonitrile, clean-up by low temperature and water precipitation, and analysis by ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI-MS-MS) using multiple reaction monitoring (MRM) mode. Most fat materials in acetonitrile extract were eliminated by low temperature clean-up. The water precipitation, providing a necessary and supplementary cleanup, could avoid losses of hydrophobic analytes (avermectins, ionophores). Average recoveries for spiked infant formula were in the range from 57% to 147% with associated RSD values between 1% and 28%. For over 80% of the analytes, the recoveries were between 70% and 120% with RSD values in the range of 1-15%. The limits of quantification (LOQs) were from 0.01 to 5 μg/kg, which were usually sufficient to verify the compliance of products with legal tolerances. Application of this method in routine monitoring programs would imply a drastic reduction of both effort and time. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rahman, Mahbubur; Heng, Lee Yook; Futra, Dedi; Ling, Tan Ling
2017-08-01
An ultrasensitive electrochemical biosensor for the determination of pathogenic Vibrio cholerae ( V. cholerae) DNA was developed based on polystyrene-co-acrylic acid (PSA) latex nanospheres-gold nanoparticles composite (PSA-AuNPs) DNA carrier matrix. Differential pulse voltammetry (DPV) using an electroactive anthraquninone oligonucleotide label was used for measuring the biosensor response. Loading of gold nanoparticles (AuNPs) on the DNA-latex particle electrode has significantly amplified the faradaic current of DNA hybridisation. Together with the use of a reported probe, the biosensor has demonstrated high sensitivity. The DNA biosensor yielded a reproducible and wide linear response range to target DNA from 1.0 × 10-21 to 1.0 × 10-8 M (relative standard deviation, RSD = 4.5%, n = 5) with a limit of detection (LOD) of 1.0 × 10-21 M ( R 2 = 0.99). The biosensor obtained satisfactory recovery values between 91 and 109% ( n = 3) for the detection of V. cholerae DNA in spiked samples and could be reused for six consecutive DNA assays with a repeatability RSD value of 5% ( n = 5). The electrochemical biosensor response was stable and maintainable at 95% of its original response up to 58 days of storage period.
Zhou, Jinhui; Xue, Xiaofeng; Li, Yi; Zhang, Jinzhen; Zhao, Jing
2007-01-01
An optimized reversed-phase high-performance liquid chromatography method was developed to detect the trans-10-hydroxy-2-decenoic acid (10-HDA) content in royal jelly cream and lyophilized powder. The sample was extracted using absolute ethanol. Chromatographic separation of 10-HDA and methyl 4-hydroxybenzoate as the internal standard was performed on a Nova-pak C18 column. The average recoveries were 95.0-99.2% (n = 5) with relative standard deviation (RSD) values of 1.3-2.1% for royal jelly cream and 98.0-100.0% (n = 5) with RSD values of 1.6-3.0% for lyophilized powder, respectively. The limits of detection and quantitation were 0.5 and 1.5 mg/kg, respectively, for both royal jelly cream and lyophilized powder. The method was validated for the determination of practical royal jelly products. The concentration of 10-HDA ranged from 1.26 to 2.21% for pure royal jelly cream samples and 3.01 to 6.19% for royal jelly lyophilized powder samples. For 30 royal jelly products, the 10-HDA content varied from not detectable to 0.98%.
An efficient repeating signal detector to investigate earthquake swarms
NASA Astrophysics Data System (ADS)
Skoumal, Robert J.; Brudzinski, Michael R.; Currie, Brian S.
2016-08-01
Repetitive earthquake swarms have been recognized as key signatures in fluid injection induced seismicity, precursors to volcanic eruptions, and slow slip events preceding megathrust earthquakes. We investigate earthquake swarms by developing a Repeating Signal Detector (RSD), a computationally efficient algorithm utilizing agglomerative clustering to identify similar waveforms buried in years of seismic recordings using a single seismometer. Instead of relying on existing earthquake catalogs of larger earthquakes, RSD identifies characteristic repetitive waveforms by rapidly identifying signals of interest above a low signal-to-noise ratio and then grouping based on spectral and time domain characteristics, resulting in dramatically shorter processing time than more exhaustive autocorrelation approaches. We investigate seismicity in four regions using RSD: (1) volcanic seismicity at Mammoth Mountain, California, (2) subduction-related seismicity in Oaxaca, Mexico, (3) induced seismicity in Central Alberta, Canada, and (4) induced seismicity in Harrison County, Ohio. In each case, RSD detects a similar or larger number of earthquakes than existing catalogs created using more time intensive methods. In Harrison County, RSD identifies 18 seismic sequences that correlate temporally and spatially to separate hydraulic fracturing operations, 15 of which were previously unreported. RSD utilizes a single seismometer for earthquake detection which enables seismicity to be quickly identified in poorly instrumented regions at the expense of relying on another method to locate the new detections. Due to the smaller computation overhead and success at distances up to ~50 km, RSD is well suited for real-time detection of low-magnitude earthquake swarms with permanent regional networks.
Yang, Wen-Tao; Gu, Jiao-Feng; Zou, Jia-Ling; Zhou, Hang; Zeng, Qing-Ru; Liao, Bo-Han
2016-10-01
The objective of the present study was to investigate the effects of rapeseed dregs (RSD, a commonly organic fertilizer in rural China) at application rates of 0, 0.75, 1.5, and 3.0 % on Cd availability in soil and its accumulation in rice plants (Oryza sativa L., Xiangwanxian 12 # , and Weiyou 46 # ) by means of a pot experiment. The results showed that application of RSD resulted in a sharp decrease in the soil TCLP-extractable Cd content. However, the soil TCLP-extractable Cd content in amended soil gradually increased during the rice growing period. Application of RSD significantly increased Cd transport from root to shoot and the amount of Cd accumulated in the aerial part. RSD was an effective organic additive for increasing rice grain yield, but total Cd content in rice grain was also increased. At an application rate of 1.5-3.0 % RSD, the total Cd content in Weiyou 46 # brown rice was 0.27-0.31 mg kg -1 , which exceeded the standard safe limit (0.2 mg kg -1 ) and was also higher than that of Xiangwanxian 12 # (0.04-0.14 mg kg -1 ). Therefore, Weiyou 46 # had a higher dietary risk than Xiangwanxian 12 # with RSD application. We do not recommend planting Weiyou 46 # and applying more than 0.75 % RSD in Cd-contaminated paddy fields.
Takemoto, Jody K; Remsberg, Connie M; Yáñez, Jaime A; Vega-Villa, Karina R; Davies, Neal M
2008-11-01
A stereospecific method for analysis of sakuranetin was developed. Separation was accomplished using a Chiralpak AD-RH column with UV (ultraviolet) detection at 288 nm. The stereospecific linear calibration curves ranged from 0.5 to 100 microg/mL. The mean extraction efficiency was >98%. Precision of the assay was <12% (relative standard deviation (R.S.D.)%), and within 10% at the limit of quantitation (0.5 microg/mL). Bias of the assay was lower than 10%, and within 5% at the limit of quantitation. The assay was applied successfully to pharmacokinetic quantification in rats, and the stereospecific quantification in oranges, grapefruit juice, and matico (Piper aduncum L.).
Meinertz, J.R.; Stehly, G.R.; Hubert, T.D.; Bernardy, J.A.
1999-01-01
A method was developed for determining benzocaine and N-acetylbenzocaine concentrations in fillet tissue of rainbow trout. The method involves extracting the analytes with acetonitrile, removing lipids or hydrophobic compounds from the extract with hexane, and providing additional clean-up with solid-phase extraction techniques. Analyte concentrations are determined using reversed-phase high-performance liquid chromatographic techniques with an isocratic mobile phase and UV detection. The accuracy (range, 92 to 121%), precision (R.S.D., <14%), and sensitivity (method quantitation limit, <24 ng/g) for each analyte indicate the usefulness of this method for studies characterizing the depletion of benzocaine residues from fish exposed to benzocaine. Copyright (C) 1999.
Li, Mengjia; Zhou, Junyi; Gu, Xue; Wang, Yan; Huang, Xiaojing; Yan, Chao
2009-01-01
A quantitative CE (qCE) system with high precision has been developed, in which a 4-port nano-valve was isolated from the electric field and served as sample injector. The accurate amount of sample was introduced into the CE system with high reproducibility. Based on this system, consecutive injections and separations were performed without voltage interruption. Reproducibilities in terms of RSD lower than 0.8% for retention time and 1.7% for peak area were achieved. The effectiveness of the system was demonstrated by the quantitative analysis of caffeine, theobromine, and theophylline in real samples, such as tea leaf, roasted coffee, coca cola, and theophylline tablets.
Analytical Parameters of an Amperometric Glucose Biosensor for Fast Analysis in Food Samples
2017-01-01
Amperometric biosensors based on the use of glucose oxidase (GOx) are able to combine the robustness of electrochemical techniques with the specificity of biological recognition processes. However, very little information can be found in literature about the fundamental analytical parameters of these sensors. In this work, the analytical behavior of an amperometric biosensor based on the immobilization of GOx using a hydrogel (Chitosan) onto highly ordered titanium dioxide nanotube arrays (TiO2NTAs) has been evaluated. The GOx–Chitosan/TiO2NTAs biosensor showed a sensitivity of 5.46 μA·mM−1 with a linear range from 0.3 to 1.5 mM; its fundamental analytical parameters were studied using a commercial soft drink. The obtained results proved sufficient repeatability (RSD = 1.9%), reproducibility (RSD = 2.5%), accuracy (95–105% recovery), and robustness (RSD = 3.3%). Furthermore, no significant interferences from fructose, ascorbic acid and citric acid were obtained. In addition, the storage stability was further examined, after 30 days, the GOx–Chitosan/TiO2NTAs biosensor retained 85% of its initial current response. Finally, the glucose content of different food samples was measured using the biosensor and compared with the respective HPLC value. In the worst scenario, a deviation smaller than 10% was obtained among the 20 samples evaluated. PMID:29135931
Error analysis regarding the calculation of nonlinear force-free field
NASA Astrophysics Data System (ADS)
Liu, S.; Zhang, H. Q.; Su, J. T.
2012-02-01
Magnetic field extrapolation is an alternative method to study chromospheric and coronal magnetic fields. In this paper, two semi-analytical solutions of force-free fields (Low and Lou in Astrophys. J. 352:343, 1990) have been used to study the errors of nonlinear force-free (NLFF) fields based on force-free factor α. Three NLFF fields are extrapolated by approximate vertical integration (AVI) Song et al. (Astrophys. J. 649:1084, 2006), boundary integral equation (BIE) Yan and Sakurai (Sol. Phys. 195:89, 2000) and optimization (Opt.) Wiegelmann (Sol. Phys. 219:87, 2004) methods. Compared with the first semi-analytical field, it is found that the mean values of absolute relative standard deviations (RSD) of α along field lines are about 0.96-1.19, 0.63-1.07 and 0.43-0.72 for AVI, BIE and Opt. fields, respectively. While for the second semi-analytical field, they are about 0.80-1.02, 0.67-1.34 and 0.33-0.55 for AVI, BIE and Opt. fields, respectively. As for the analytical field, the calculation error of <| RSD|> is about 0.1˜0.2. It is also found that RSD does not apparently depend on the length of field line. These provide the basic estimation on the deviation of extrapolated field obtained by proposed methods from the real force-free field.
Almeida, Carlos; Ahmad, Samir M; Nogueira, José Manuel F
2017-03-01
In the present work, bar adsorptive microextraction using miniaturized devices (7.5 × 3.0 mm) coated with suitable sorbent phases, combined with microliquid desorption (100 μL) followed by high-performance liquid chromatography with diode array detection (BAμE-μLD/HPLC-DAD), is proposed for the determination of trace level of six pharmaceuticals (furosemide, mebeverine, ketoprofen, naproxen, diclofenac and mefenamic acid) in environmental water and urine matrices. By comparing ten distinct sorbent materials (five polymeric and five activated carbons), the polymer P5 proved to be the most suitable to achieve the best selectivity and efficiency. The solvent volume minimization in the liquid desorption stage demonstrated remarkable effectiveness, being more environmentally friendly, and simultaneously increased the microextraction enrichment factor two-fold. Assays performed through BAμE(P5, 0.9 mg)-μLD(100 μL)/HPLC-DAD on 25 mL of ultrapure water samples spiked at the 4.0 μg/L level yielded average recoveries ranging from 91.4% (furosemide) to 101.0% (ketoprofen) with good precision (RSD < 10.6%), under optimized experimental conditions. The analytical performance showed convenient detection limits (25.0 - 120.0 ng/L), good linear dynamic ranges (0.1 to 24.0 μg/L), appropriate determination coefficients (r 2 > 0.9983), and excellent repeatability through intraday (RSD < 10.4%)) and interday (RSD < 10.0%) assays. By using the standard addition methodology, the application of the present analytical approach on environmental waters and urine samples revealed the occurrence of trace levels of some pharmaceuticals. The solvent minimization during the back-extraction step associated with the miniaturization of BAμE devices proved to be a very promising analytical technology for static microextraction analysis. Graphical abstract BAμE operating under the floating sampling technology for the determination of pharmaceuticals in aqueous media.
Speciation analysis of inorganic antimony in soil using HPLC-ID-ICP-MS.
Amereih, Sameer; Meisel, Thomas; Kahr, Elisabeth; Wegscheider, Wolfhard
2005-12-01
Speciation analysis of Sb(III) and Sb(V) in a soil sample was performed through extraction and on-line isotope dilution concentration determination after a chromatographic separation. The total Sb concentration found in a through traffic contaminated soil sample was (4.17 microg g(-1), 0.3 microg g(-1) SD, n=6). It was determined using ICP-MS after soil digestion using the sodium peroxide sintering method. The optimized extraction procedure for speciation analysis was carried out using 100 mmol L(-1) citric acid at pH 2.08 by applying an ultrasonic bath for 45 min at room temperature. The effects of citric acid concentration (0-500 mmol L(-1)), pH (1-6), and temperature (30-60 degrees C) on inorganic antimony species distribution in the examined sample were studied and optimized. The separation of Sb(III) and Sb(V) was achieved using an anion exchange column (PRP-X100) and 10 mmol L(-1) EDTA and 1 mmol L(-1) phthalic acid at pH 4.5 as a mobile phase. The eluent from the HPLC was mixed with an enriched (94.2%) (123)Sb spike solution that was pumped by a peristaltic pump with a constant flow rate (0.5 mL min(-1)) in a three-way valve. The blend passed directly to the Conikal nebulizer of the ICP-MS. By using the above extraction procedure and methodology, 43.2% Sb(V) (2.9% RSD, n=3) and 6.0% Sb(III) (1.3% RSD, n=3) of total Sb found in the sample could be detected. The detection limits achieved by the proposed method were 20 ng L(-1) and 65 ng L(-1) for Sb(V) and Sb(III), respectively. The precision, evaluated by using RSD with 100 ng L(-1) calibration solutions, was 2.7% and 3.2% (n=6) for Sb(V) and Sb(III), respectively, in aqueous solutions.
Wang, Neng; Zheng, Xiaoxin; Qian, Jin; Yao, Wei; Bai, Lu; Hou, Guo; Qiu, Xuan; Li, Xiaoyan; Jiang, Xuejun
2017-10-01
The aim of the present study was to determine if renal sympathetic denervation (RSD) may alleviate isoproterenol-induced left ventricle remodeling, and to identify the underlying mechanism. A total of 70 rats were randomly divided into control (n=15), sham operation (n=15), heart failure (HF) with sham operation (HF + sham; n=20) and HF with treatment (HF + RSD; n=20) groups. The HF model was established by subcutaneous injection of isoproterenol; six weeks later, 1eft ventricular internal diameter at end‑systole (LVIDs), left ventricular systolic posterior wall thickness (LVPWs), 1eft ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were measured. Plasma norepinephrine (NE), angiotensin II (Ang II) and aldosterone (ALD) levels were measured by ELISA. Myocardial collagen volume fraction (CVF) was determined by Masson's staining. Reverse transcription‑quantitative polymerase chain reaction was used to determine the mRNA expression levels of ventricular transforming growth factor‑β (TGF‑β), connective tissue growth factor (CTGF) and microRNAs (miRs), including miR‑29b, miR‑30c and miR‑133a. The results demonstrated that LVIDs and LVPWs in the HF + RSD group were significantly decreased compared with the HF + sham group. By contrast, LVFS and LVEF in the HF + RSD group were significantly increased compared with the HF + sham group. RSD significantly reduced the levels of plasma NE, Ang II and ALD. CVF in the HF + RSD group was reduced by 38.1% compared with the HF + sham group. Expression levels of TGF‑β and CTGF were decreased, whereas those of miR‑29b, miR‑30c and miR‑133a were increased, in the HF + RSD group compared with the HF + sham group. These results indicated that RSD alleviates isoproterenol‑induced left ventricle remodeling potentially via downregulation of TGF‑β/CTGF and upregulation of miR‑29b, miR‑30c and miR‑133a. RSD may therefore be an effective non‑drug therapy for the treatment of heart failure.
Wang, Neng; Zheng, Xiaoxin; Qian, Jin; Yao, Wei; Bai, Lu; Hou, Guo; Qiu, Xuan; Li, Xiaoyan; Jiang, Xuejun
2017-01-01
The aim of the present study was to determine if renal sympathetic denervation (RSD) may alleviate isoproterenol-induced left ventricle remodeling, and to identify the underlying mechanism. A total of 70 rats were randomly divided into control (n=15), sham operation (n=15), heart failure (HF) with sham operation (HF + sham; n=20) and HF with treatment (HF + RSD; n=20) groups. The HF model was established by subcutaneous injection of isoproterenol; six weeks later, 1eft ventricular internal diameter at end-systole (LVIDs), left ventricular systolic posterior wall thickness (LVPWs), 1eft ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were measured. Plasma norepinephrine (NE), angiotensin II (Ang II) and aldosterone (ALD) levels were measured by ELISA. Myocardial collagen volume fraction (CVF) was determined by Masson's staining. Reverse transcription-quantitative polymerase chain reaction was used to determine the mRNA expression levels of ventricular transforming growth factor-β (TGF-β), connective tissue growth factor (CTGF) and microRNAs (miRs), including miR-29b, miR-30c and miR-133a. The results demonstrated that LVIDs and LVPWs in the HF + RSD group were significantly decreased compared with the HF + sham group. By contrast, LVFS and LVEF in the HF + RSD group were significantly increased compared with the HF + sham group. RSD significantly reduced the levels of plasma NE, Ang II and ALD. CVF in the HF + RSD group was reduced by 38.1% compared with the HF + sham group. Expression levels of TGF-β and CTGF were decreased, whereas those of miR-29b, miR-30c and miR-133a were increased, in the HF + RSD group compared with the HF + sham group. These results indicated that RSD alleviates isoproterenol-induced left ventricle remodeling potentially via downregulation of TGF-β/CTGF and upregulation of miR-29b, miR-30c and miR-133a. RSD may therefore be an effective non-drug therapy for the treatment of heart failure. PMID:28849013
Zheng, Xiao-Xin; Li, Xiao-Yan; Lyu, Yong-Nan; He, Yi-Yu; Wan, Wei-Guo; Zhu, Hong-Ling; Jiang, Xue-Jun
2016-02-01
What is the central question of this study? The enzyme system that is responsible for extracellular matrix (ECM) turnover is the matrix metalloproteinases (MMPs), which can be blocked by the tissue inhibitors of MMPs (TIMPs). Whether renal sympathetic denervation (RSD) is able to ameliorate post-myocardial infarction left ventricular remodelling through attenuation of ECM via regulation of MMP activity and/or the MMP-TIMP complex remains unknown. What is the main finding and its importance? Renal sympathetic denervation has therapeutic effects on post-myocardial infarction left ventricular remodelling, probably by attenuating the ECM through regulation of the MMP9-TIMP1 complex in the transforming growth factor-β1 (a profibrotic cytokine that accelerates ECM remodelling after ischaemia) signalling pathway. Whether renal sympathetic denervation (RSD) is able to ameliorate post-myocardial infarction (post-MI) left ventricular (LV) remodelling by attenuation of the extracellular matrix via regulation of matrix metalloproteinase (MMP) activity and/or the MMP-tissue inhibitor of matrix metalloproteinase (TIMP) complex remains unknown. Sixty-five Sprague-Dawley rats were randomly divided into the following four groups: normal (N, n = 15), RSD (RSD, n = 15), myocardial infarction (MI, n = 15) and RSD 3 days after MI (MI3d+RSD, n = 20). The bilateral renal nerves were surgically denervated 3 days after MI had been induced by coronary artery ligation. Left ventricular function was assessed using echocardiography and a Millar catheter at 6 weeks post-MI. Plasma noradrenaline, angiotensin II and aldosterone, collagen volume fraction, transforming growth factor-β1 (TGF-β1), MMP2, MMP9 and TIMP1 in heart tissue were measured 6 weeks after MI. In rats with MI3d+RSD compared with MI rats, RSD improved systolic and diastolic function, resulting in an improvement in ejection fraction (P < 0.05), fractional shortening (P < 0.05) and LV internal dimension in systole (P < 0.05) and diastole (P < 0.05). Additionally, RSD treatment decreased left ventricular end-diastolic pressure (P < 0.05) and increased LV systolic pressure (P < 0.05) and maximal and minimal rate of LV pressure (both P < 0.05). Meanwhile, RSD reduced collagen content (P < 0.01). TIMP1 was upregulated (P < 0.05), whereas MMP2, MMP9 and TGF-β1 were downregulated in the LV of RSD-treated animals (P < 0.05). Renal sympathetic denervation has therapeutic effects on post-MI LV remodelling, probably owing to effects on the extracellular matrix by regulation of the MMP9-TIMP1 balance in the TGF-β1 signalling pathway. Renal sympathetic denervation may be considered as a non-pharmacological approach for the improvement of post-MI cardiac dysfunction. © 2015 The Authors. Experimental Physiology © 2015 The Physiological Society.
Gong, Xiaojian; Luan, Qingxiang; Zhou, Xin; Zhao, Yang; Zhao, Chao
2017-11-01
This study aimed to develop a specific UHPLC-ESI-MS/MS method for simultaneous determination and pharmacokinetics of pinoresinol glucoside and chlorogenic acid in rat plasma after oral administration of Eucommia ulmoides. The chromatographic separation was achieved on a Hypersil GOLD column with gradient elution by using a mixture of 0.1% formic acid aqueous solution and acetonitrile as the mobile phase at a flow rate of 200 μL/min. A tandem mass spectrometric detection was conducted using multiple-reaction monitoring via an electrospray ionization source in negative ionization mode. Samples were pre-treated by a single-step protein precipitation with acetonitrile, and bergenin was used as internal standard. After oral administration of 3 mL/kg E. ulmoides extract in rats, the maximum plasma concentrations of pinoresinol glucoside and chlorogenic acid were 57.44 and 61.04 ng/mL, respectively. The times to reach the maximum plasma concentration were 40.00 and 23.33 min for pinoresinol glucoside and chlorogenic acid, respectively. The intra- and inter-day precision (RSD) values for the two analytes were <2.46 and 5.15%, respectively, and the accuracy (RE) values ranged from -12.76 to 0.00. This is the first study on pharmacokinetics of bioactive compounds in rat plasma after oral administration of E. ulmoides extract. Copyright © 2017 John Wiley & Sons, Ltd.
An Experimental Design Approach for Impurity Profiling of Valacyclovir-Related Products by RP-HPLC
Katakam, Prakash; Dey, Baishakhi; Hwisa, Nagiat T; Assaleh, Fathi H; Chandu, Babu R; Singla, Rajeev K; Mitra, Analava
2014-01-01
Abstract Impurity profiling has become an important phase of pharmaceutical research where both spectroscopic and chromatographic methods find applications. The analytical methodology needs to be very sensitive, specific, and precise which will separate and determine the impurity of interest at the 0.1% level. Current research reports a validated RP-HPLC method to detect and separate valacyclovir-related impurities (Imp-E and Imp-G) using the Box-Behnken design approach of response surface methodology. A gradient mobile phase (buffer: acetonitrile as mobile phase A and acetonitrile: methanol as mobile phase B) was used. Linearity was found in the concentration range of 50–150 μg/mL. The mean recovery of impurities was 99.9% and 103.2%, respectively. The %RSD for the peak areas of Imp-E and Imp-G were 0.9 and 0.1, respectively. No blank interferences at the retention times of the impurities suggest the specificity of the method. The LOD values were 0.0024 μg/mL for Imp-E and 0.04 μg/mL for Imp-G and the LOQ values were obtained as 0.0082 μg/mL and 0.136 μg/mL, respectively, for the impurities. The S/N ratios in both cases were within the specification limits. Proper peak shapes and satisfactory resolution with good retention times suggested the suitability of the method for impurity profiling of valacyclovir-related drug substances. PMID:25853072
Nardin, Tiziana; Barnaba, Chiara; Abballe, Franco; Trenti, Gianmaria; Malacarne, Mario; Larcher, Roberto
2017-10-01
A fast separation based on cation-exchange liquid chromatography coupled with high-resolution mass spectrometry is proposed for simultaneous determination of chlormequat, difenzoquat, diquat, mepiquat and paraquat in several food and beverage commodities. Solid samples were extracted using a mixture of water/methanol/formic acid (69.6:30:0.4, v/v/v), while liquid samples were ten times diluted with the same solution. Separation was carried out on an experimental length-modified IonPac CS17 column (2 × 15 mm 2 ) that allowed the use of formic acid and acetonitrile as mobile phase. Detection limits for food and beverage matrices were established at 1.5 μg/L for chlormequat, difenzoquat and mepiquat, and 3 μg/L for diquat and paraquat, while for drinking water a pre-analytical sample concentration allowed detection limits of 9 and 20 ng/L, respectively. Precision, as repeatability (RSD%), ranged from 0.2 to 24%, with a median value of 6%, and trueness, as recovery, ranged from 64 to 118%, with a median value of 96%. The method developed was successfully applied to investigate the presence of herbicide residues in commercial commodities (mineral water, orange juice, beer, tea, green coffee bean, toasted coffee powder, cocoa bean, white corn flour, rice and sugar samples). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Márquez-Sillero, Isabel; Cárdenas, Soledad; Valcárcel, Miguel
2013-10-25
A simple and rapid method for the simultaneous determination of seven water-soluble vitamins (thiamine, folic acid, nicotinic acid, ascorbic acid, pantothenic acid, pyridoxine and biotin) was developed by high performance liquid chromatographic separation and corona-charged aerosol detection. The water-soluble vitamins were separated on a Lichrosorb RP-C18 column under isocratic conditions with a mobile phase consisting of 0.05 M ammonium acetate:methanol 90:10 (v/v) at the flow rate 0.5 mL min(-1). The vitamins were extracted from the infant milk (liquid and powder format) using a precipitation step with 2.5 M acetic acid remaining the analyte in the supernatant. As far as dietary supplements are concerned, only a dilution with distilled water was required. The detection limits ranged from 0.17 to 0.62 mg L(-1) for dietary supplements and 1.7 to 6.5 mg L(-1) for milk samples. The precision of the method was evaluated in terms of relative standard deviation (%, RSD) under repeatability and reproducibility conditions, being the average values for each parameter 2.6 and 2.7 for dietary supplements and 4.3 and 4.6 for milk samples. The optimized method was applied to different infant milk samples and dietary supplements. The results of the analysis were in good agreement with the declared values. Copyright © 2013 Elsevier B.V. All rights reserved.
Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments
2015-08-01
control RPD relative percent difference RSD relative standard deviation SERDP Strategic Environmental Research and Development Program SOPs...sediments from 2 stations, each at 4 PCB spike levels, for four individual congeners was 22 ± 6 % relative standard deviation ( RSD ). Also, comparison of... RSD (Table 3). However, larger congeners (e.g., congeners #153 and 180) whose approach to equilibrium is less certain, based on small fractions of
Demonstration of the Gore Module for Passive Ground Water Sampling
2014-06-01
ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70
Quantitative sensory studies in complex regional pain syndrome type 1/RSD.
Tahmoush, A J; Schwartzman, R J; Hopp, J L; Grothusen, J R
2000-12-01
Patients with complex regional pain syndrome type I (CRPSD1) may have thermal allodynia after application of a non-noxious thermal stimulus to the affected limb. We measured the warm, cold, heat-evoked pain threshold and the cold-evoked pain threshold in the affected area of 16 control patients and patients with complex regional pain syndrome type 1/RSD to test the hypothesis that allodynia results from an abnormality in sensory physiology. A contact thermode was used to apply a constant 1 degrees C/second increasing (warm and heat-evoked pain) or decreasing (cold and cold-evoked pain) thermal stimulus until the patient pressed the response button to show that a temperature change was felt by the patient. Student t test was used to compare thresholds in patients and control patients. The cold-evoked pain threshold in patients with CRPSD1/RSD (p <0.001) was significantly decreased when compared with the thresholds in control patients (i.e., a smaller decrease in temperature was necessary to elicit cold-pain in patients with CRPSD1/RSD than in control patients). The heat-evoked pain threshold in patients with CRPS1/RSD was (p <0.05) decreased significantly when compared with thresholds in control patients. The warm- and cold-detection thresholds in patients with CRPS1/RSD were similar to the thresholds in control patients. This study suggests that thermal allodynia in patients with CRPS1/RSD results from decreased cold-evoked and heat-evoked pain thresholds. The thermal pain thresholds are reset (decreased) so that non-noxious thermal stimuli are perceived to be pain (allodynia).
Gatti, Rita; Vitellaro, Valeria
2013-12-04
The use of menadione (MD) as a pre-column reagent for high performance liquid chromatography (HPLC) analysis of aliphatic thiols is proposed. The reaction was carried out for 5 min at room temperature and pH 8.5. The developed method was applied to the N-acetylcysteine (NAC) analysis of alimentary supplements and pharmaceutical formulations. The effect of the complex matrix was evaluated by the study of the thiol derivatization reaction both in standard and in placebo solutions. The yield of NAC-MD adduct was found to be quantitative at a reagent to thiol molar ratio of about 4 in comparison with an authentic specimen of synthesized NAC adduct, which was characterized by (1)H NMR, IR and UV. The routine chromatographic separations were performed on a Synergi MAX-RP column using a mobile phase consisting of methanol/triethylammonium (TEA) phosphate buffer (pH 3; 0.05 mol L(-1)) 70:30 (v/v) at a flow-rate of 0.4 mL min(-1). UV-diode array detection was used setting the wavelength at λ=260 nm. The validation parameters such as linearity, sensitivity, accuracy, precision, selectivity and ruggedness were found to be highly satisfactory. Similar linear responses were observed by standard and placebo solutions (determination coefficient: 0.9996). Limit of detection was about 0.019 μg g(-1). Intra-day precision (relative standard deviation, R.S.D.) was ≤0.81% for NAC to internal standard (IS) peak area ratio, ≤0.28% and ≤0.32%, respectively, for NAC and IS retention times (tR), without significant differences between intra- and inter-day data. NAC recovery studies gave good results (100.12%) with R.S.D.=1.05%. Copyright © 2013 Elsevier B.V. All rights reserved.
Teglia, Carla M; Cámara, María S; Goicoechea, Héctor C
2014-12-01
This paper reports the development of a method based on high-performance liquid chromatography (HPLC) coupled to second-order data modeling with multivariate curve resolution-alternating least-squares (MCR-ALS) for quantification of retinoic acid and its main isomers in plasma in only 5.5 min. The compounds retinoic acid (RA), 13-cis-retinoic acid, 9-cis-retinoic acid, and 9,13-di-cis-retinoic acid were partially separated by use of a Poroshell 120 EC-C18 (3.0 mm × 30 mm, 2.7 μm particle size) column. Overlapping not only among the target analytes but also with the plasma interferents was resolved by exploiting the second-order advantage of the multi-way calibration. A validation study led to the following results: trueness with recoveries of 98.5-105.9 % for RA, 95.7-110.1 % for 13-cis-RA, 97.1-110.8 % for 9-cis-RA, and 99.5-110.9 % for 9,13-di-cis-RA; repeatability with RSD of 3.5-3.1 % for RA, 3.5-1.5 % for 13-cis-RA, 4.6-2.7 % for 9-cis-RA, and 5.2-2.7 % for 9,13-di-cis-RA (low and high levels); and intermediate precision (inter-day precision) with RSD of 3.8-3.0 % for RA, 2.9-2.4 % for 13-cis-RA, 3.6-3.2 % for 9,13-di-cis-RA, and 3.2-2.9 % for 9-cis-RA (low and high levels). In addition, a robustness study revealed the method was suitable for monitoring patients with dermatological diseases treated with pharmaceutical products containing RA and 13-cis-RA.
Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Do, Jung-Ah; Cho, Sooyeul; Baek, Sun Young; Park, Sung-Kwan
2016-06-01
The primary purpose of this study was to develop and validate a method based on UPLC with UV and UPLC-MS-MS for the simultaneous analysis of different cannabinoids and synthetic cannabinoids in food as well as in herbal and dietary supplements. The limits of detection and quantitation of the method ranged from 0.1 to 0.3 and 0.3 to 0.9 μg/mL by UPLC with UV, respectively. The coefficient of determination was >0.999; the intra- and interday precision of the method were 0.1-3.7 and 0.9-4.1%, respectively. The intra- and interday accuracy were 94.8-103.1 and 98.3-100.9%, respectively. The mean recoveries of nine cannabinoids obtained from tablet samples ranged from 81.1 to 105.4%. The mean extraction recoveries of nine target cannabinoids obtained from various types of samples (tablets, capsules, powders, liquids, cookies and candies) ranged from 82.26 to 112.40%. The relative standard deviation (RSD) of the stability of the prepared sample solutions was <1.80%. Identification and quantification of the nine cannabinoids were accomplished by ion spray UPLC-MS-MS using multiple reaction monitoring. The UPLC-MS-MS method was validated for linearity (R(2) > 0.99); the precision was 0.1-4.0% (intraday) and 0.1-2.8% (interday), and the accuracy was 98.0-103.5% (intraday) and 97.1-103.2% (interday). The mean extraction recoveries of six types of samples were 82.2-114.5% and the RSD of stability was <6.54%, complying with the established international guidelines. The results indicated that the method can be used for rapid and accurate screening of cannabinoids present in food. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gatti, R; Andreatta, P; Boschetti, S
2013-07-12
A RP-HPLC method with pre-column derivatization was developed and validated for the simultaneous quantification of carnosine (Carn), acetylcarnitine taurinate (AC-Tau), asparagine (Asn), potassium aspartate (Asp) and for the determination of phosphoserine (p-Ser) in new and commercial alimentary supplements. The effect of complex matrices was evaluated by the study of the amino acid derivatization reaction with 2,4-dinitrofluorobenzene (DNFB) both in standard and placebo solutions. The reaction was carried out for 20 min at 70 °C in alkaline medium (pH10) for p-Ser analysis, whereas for 60 min in the case of Carn, AC-Tau, Asn and Asp analysis. The adducts have been separated on a Discovery RP Amide C16 (250 mm×4.6mm, i.d.) column using a mobile phase consisting of acetonitrile (ACN) and triethylammonium (TEA) phosphate buffer (pH 3, 0.05 M) under gradient elution conditions at a flow-rate of 0.8 mL/min. Detection was set at λ=360 nm. The validation parameters such as linearity, sensitivity, accuracy, precision and specificity were found to be highly satisfactory. Linear responses were observed by placebo solutions (determination coefficient ≤0.9996). Intra-day precision (relative standard deviation, RSD) was ≤1.06% for corrected peak area and ≤0.99% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all examined compounds (from 97.7% to 101.5%) with RSD ranging from 0.5% to 1.3%). The high stability of derivatized compound solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of a large number of samples and consecutive chromatographic analyses by the use of an autosampler. The developed method can be considered suitable for the quality control of new and commercial products. Copyright © 2013 Elsevier B.V. All rights reserved.
Kiuchi, Márcio Galindo; E Silva, Gustavo Ramalho; Paz, Luis Marcelo Rodrigues; Chen, Shaojie; Souto, Gladyston Luiz Lima
2016-11-01
Polymorphic premature ventricular complexes (PVCs) are very common, appearing most frequently in patients with hypertension, obesity, sleep apnea, and structural heart disease. Sympathetic hyperactivity plays a critical role in the development, maintenance, and aggravation of ventricular arrhythmias. Recently, the relevance of sympathetic activation in patients with ventricular arrhythmias was reported, and this finding suggested a potential role for catheter-based renal sympathetic denervation in reducing the arrhythmic burden. We evaluated the effectiveness of the renal sympathetic denervation (RSD) in comparison to antiarrhythmic pharmacologic therapy in reducing polymorphic PVCs refractory to medication therapy and cardiac parameters assessed by 24-h Holter monitoring and cardiac magnetic resonance (CRM), respectively, in patients with structurally normal heart. Thirty-four patients were included in this study, 14 served as control, and 20 were treated with an ablation cardiac catheter with open irrigated tip. RSD was performed by a single operator following the standard technique. All the patients included had polymorphic PVCs and structurally normal heart. Data were obtained at baseline at the 12th month of follow-up (sixth month after RSD or adjustment of antiarrhythmic dosage). In RSD group, we observed a significant decrease in the number of polymorphic PVCs from baseline 36,091 ± 3327 to 3, 6, 7 (first month after RSD, without drugs), and 12 months (sixth month after RSD, without drugs) of follow-up, 31,009 ± 3251, 20,411 ± 3820, 7701 ± 1549, and 1274 ± 749, respectively, in all patients, P < 0.0001 to all the comparisons between the mean of each time point with the mean of every other time point. No changes in mean 24-h ABPM and renal function in both groups were observed at 12th month of follow-up. However, 24-h Holter mean heart rate decreased in control group at 12th month of follow-up, which did not happen with the RSD group. At the sixth month post-RSD in comparison to baseline, a significant reduction in the number of polymorphic PVCs (∆ = -34,817 ± 3590, P < 0.0001) was observed, as well as, in CRM parameters such as left ventricular mass/body surface area (∆ = -5.4 ± 2.1 g/m 2 , P < 0.0001) and left ventricular ejection fraction (∆ = +3.0 ± 1.8 %, P < 0.0001). In comparison to control group at the same time point, these findings were statistically superior in RSD group (P > 0.05). A significant correlation was found between the Δ number of polymorphic PVCs at the sixth month (r = -0.6723, P = 0.0012) after the RSD and the total number of RSD ablated spots. Polymorphic PVCs refractory to medication therapy may be modifiable by RSD in patients without structural heart disease. Although encouraging, our data are preliminary and need to be validated in a large population and in long term.
Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam
2017-01-01
Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748
Naveen, P; Lingaraju, H B; Prasad, K Shyam
2017-01-01
Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.
Kiuchi, Márcio Galindo; Chen, Shaojie; Rodrigues Paz, Luis Marcelo; Pürerfellner, Helmut
2017-01-01
Chronic kidney disease (CKD) patients on stage 4 present greater risk rates for malignant ventricular arrhythmia events. This study examined patients with CKD in stages 1, 2, 3 and 4, left ventricular dysfunction and automatic implantable cardioverter-defibrillator (ICD). Our goal was to record the appropriate therapies, “Anti-tachycardia Therapy Pacing” (ATP) and shock events during the 18 months of follow-up and compare the incidence and severity of these at different stages of CKD, mainly in patients with CKD stage 4 underwent renal sympathetic denervation (RSD) guided by renal nerve stimulation (RNS). One hundred and fifteen patients were evaluated once every three months till 18 months of follow-up. The arrhythmic events were assessed at each follow-up visit. Comparing the groups, we can see the number of ATP and shock events recorded by ICD during 18 months of follow-up, and differences in the number of therapeutic events between the various stages of CKD. The hazard ratio (HR), 95% confidence interval (CI) and P value for ATP and shock events between all the CKD stages were evaluated by the log-rank/Mantel-Haenszel test. At the 18th month of follow-up, 75% of patients with CKD stage 4 received ATP, and 70% were treated with shock while only 20% of the subjects with CKD stage 4 that were submitted to RSD received ATP and 20% were treated with shock, P<0.0001 and P=0.0002, respectively. In our study, a decline occurred in the incidence of arrhythmias, and therefore, appropriate ICD therapies in advanced stages of CKD, reducing the risk rates for these events in patients with CKD on stage 4 after RSD guided by RNS in comparison to the other CKD stages. Our results suggest that RSD can control the higher incidence of malignant arrhythmias in advanced CKD stages. PMID:28415795
Lau, Aik-Jiang; Holmes, Michael J; Woo, Soo-On; Koh, Hwee-Ling
2003-02-26
Adulterations with synthetic drugs are common problems with herbal medicine and this can potentially cause serious adverse effects. It is therefore important to determine the presence of synthetic drugs in herbal medicine to ensure patients' safety. The objective of this study was to develop sensitive and specific methods to analyse phenylbutazone, caffeine and oxyphenbutazone present in a traditional Indonesian herbal product. Liquid chromatography-mass spectrometry-mass spectrometry (LC-MS-MS) methods in the selected reaction-monitoring (SRM) mode were developed. It was found that the sample contained 0.53% w/w (n=3, RSD=7.56%) phenylbutazone and 0.04% w/w (n=3, RSD=8.39%) caffeine. This corresponded to 43.17 mg phenylbutazone and 3.23 mg caffeine in each sachet of powder. The methods were validated for linearity, precision, accuracy, LOD and LOQ. LOD and LOQ were found to be 3.69 and 12.29 ng/ml, respectively for phenylbutazone. For caffeine, the LOD and LOQ were 0.84 and 2.80 ng/ml, respectively. Oxyphenbutazone in the sample was found to be present at a level below the quantification level of 10.2 ng/ml. With better methods developed for analysis of adulterants in herbal medicine, the quality and safety of these medicines can be better controlled and regulated to ensure patients' safety.
Chen, Jue; Liu, Mengjun; Wang, Qi; Du, Huizhi; Zhang, Liwei
2016-10-17
Deep eutectic solvents (DESs) have attracted significant attention as a promising green media. In this work, twenty-five kinds of benign choline chloride-based DESs with microwave-assisted methods were applied to quickly extract active components from Radix Salviae miltiorrhizae . The extraction factors, including temperature, time, power of microwave, and solid/liquid ratio, were investigated systematically by response surface methodology. The hydrophilic and hydrophobic ingredients were extracted simultaneously under the optimized conditions: 20 vol% of water in choline chloride/1,2-propanediol (1:1, molar ratio) as solvent, microwave power of 800 W, temperature at 70 °C, time at 11.11 min, and solid/liquid ratio of 0.007 g·mL -1 . The extraction yield was comparable to, or even better than, conventional methods with organic solvents. The microstructure alteration of samples before and after extraction was also investigated. The method validation was tested as the linearity of analytes ( r ² > 0.9997 over two orders of magnitude), precision (intra-day relative standard deviation (RSD) < 2.49 and inter-day RSD < 2.96), and accuracy (recoveries ranging from 95.04% to 99.93%). The proposed DESs combined with the microwave-assisted method provided a prominent advantage for fast and efficient extraction of active components, and DESs could be extended as solvents to extract and analyze complex environmental and pharmaceutical samples.
[Determination of 5 nucleosides components in culture of Paecilomyces hepialid by HPLC].
Yang, Dan; Ma, Yun-shu; Huang, Ting-ting; Chen, Cheng
2015-08-01
The concentration of 5 nucleosides, uracil, uridine, guanidine, adenine and adenosine in culture of Paecilomyces hepialid was determined by the developed method of HPLC. The HPLC method was performed on a Waters SunFire C18 (4.6 mm x 250 mm, 5 μm) column with methanol-water gradient elution as the mobile phase. The detection wavelength was 260 nm and the colunmn temperature was controlled at 30 °C. The linear range was 10.00-200.00 mg · L(-1) (r = 0.9994) for uracil, 10.10-202.00 mg · L(-1) (r = 0.9992) for uridine, 10.00-200.00 mg · L(-1) (r = 0.9991) for guanidine, 10.30-206.00 mg · L(-1) (r = 0.9992) for adenine and 10.45-209.00 mg · L(-1) (r = 0.9991) for adenosine, respectively. The RSD of precision was 0.032%, 0.035%, 0.039%, 0.049%, 0.00080%, respectively. The average recoveries of uracil, guanidine, adenine, and adenosine were 97.34%, 99.10%, 101.6%, 98.61% and 100.2% with RSD of 1.3%, 2.1%, 0.96%, 0.95%, and 1.3% respectively. The method showed high sensitivity, good selectivity, linearity and repeatability, which was suitable for the content analysis of 5 nucleosides components in P. hepialid and its extracts.
Zhang, Yi-Bei; DA, Juan; Zhang, Jing-Xian; Li, Shang-Rong; Chen, Xin; Long, Hua-Li; Wang, Qiu-Rong; Cai, Lu-Ying; Yao, Shuai; Hou, Jin-Jun; Wu, Wan-Ying; Guo, De-An
2017-04-01
Aconiti Lateralis Radix Praeparata (Fuzi) is a commonly used traditional Chinese medicine in clinic for its potency in restoring yang and rescuing from collapse. Aconiti alkaloids, mainly including monoester-diterpenoidaconitines (MDAs) and diester-diterpenoidaconitines (DDAs), are considered to act as both bioactive and toxic constituents. In the present study, a feasible, economical, and accurate HPLC method for simultaneous determination of six alkaloid markers using the Single Standard for Determination of Multi-Components (SSDMC) method was developed and fully validated. Benzoylmesaconine was used as the unique reference standard. This method was proven as accurate (recovery varying between 97.5%-101.8%, RSD < 3%), precise (RSD 0.63%-2.05%), and linear (R > 0.999 9) over the concentration ranges, and subsequently applied to quantitative evaluation of 62 batches of samples, among which 45 batches were from good manufacturing practice (GMP) facilities and 17 batches from the drug market. The contents were then analyzed by principal component analysis (PCA) and homogeneity test. The present study provided valuable information for improving the quality standard of Aconiti Lateralis Radix Praeparata. The developed method also has the potential in analysis of other Aconitum species, such as Aconitum carmichaelii (prepared parent root) and Aconitum kusnezoffii (prepared root). Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Li, J.S.; Chen, M.; Li, Z.C.
2012-01-01
A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extracted with 0.5 M HCl and purified by liquid-liquid partition with hexane. The parameters for reverse-phase (C18) LC and positive ESI/MS/MS were optimized. The matrix effect, specificity, linearity, precision, accuracy and reproducibility of the method were determined and evaluated. The method was linear over a range of 0.10–10.00 ng/mL examined, with R2 of 0.99 for both 1,3-DMAA and 1,4-DMAA. The recoveries from spiked concentrations between 5.00–40.00 ng/g were 85.1%–104.9% for 1,3-DMAA, with relative standard deviation (RSD) of 2.9%–11.0%, and 82.9%–101.8% for 1,4-DMAA, with RSD of 3.2%–11.7%. The instrument detection limit was 1–2 pg for both DMAAs. The quantification limit was estimated to be 1–2 ng/g for the plant sample. This method was successfully applied to the quantitative determination of 1,3- and 1,4-DMAA in both geranium plant and geranium oil. PMID:22915838
2013-01-01
Background Shen-Fu decoction is a traditional Chinese medicine prescription with a 3:2 ratio of Radix Ginseng and Fuzi (Radix Aconiti lateralis praeparata). Ginsenosides and alkaloids are considered to be the main active components of Shen-Fu decoction. However, no analytical methods have been used to quantitatively analyse both components in Shen-Fu decoction simultaneously. Results We successfully developed a rapid resolution liquid chromatography coupled with tandem mass spectrometry (RRLC-MS/MS) method for the simultaneous analysis of seven ginsenosides and three aconitum alkaloids in Shen-Fu decoction, the decoction of Radix ginseng and Fuzi (Radix Aconiti lateralis praeparata). Chromatogrpahic separation by RPLC was achieved using a reversed-phase column and a water/acetonitrile mobile phase, containing 0.05% formic acid and using a gradient system. The method was optimized to allow for simultaneous analysis of all analytes in 11minutes without the need for baseline resolution of the components. Furthermore, the separation demonstrated good linearity (r > 0.9882), repeatability (RSD < 7.01%), intra- and inter-day precisions (RSD < 5.06%) and high yields of recovery (91.13-111.97%) for ten major constituents, namely ginsenoside-Re, Rg1, Rb1, Rc, Rb2, Rd, Rf, aconitine, hypacoitine and mesaconitine. Conclusions The developed method could be used as a rapid and reliable approach for assessment of the quantity of the major constituents in Shen-Fu decoction. PMID:24107599
Application of snapshot imaging spectrometer in environmental detection
NASA Astrophysics Data System (ADS)
Sun, Kai; Qin, Xiaolei; Zhang, Yu; Wang, Jinqiang
2017-10-01
This study aimed at the application of snapshot imaging spectrometer in environmental detection. The simulated sewage and dyeing wastewater were prepared and the optimal experimental conditions were determined. The white LED array was used as the detection light source and the image of the sample was collected by the imaging spectrometer developed in the laboratory to obtain the spectral information of the sample in the range of 400-800 nm. The standard curve between the absorbance and the concentration of the samples was established. The linear range of a single component of Rhoda mine B was 1-50 mg/L, the linear correlation coefficient was more than 0.99, the recovery was 93%-113% and the relative standard deviations (RSD) was 7.5%. The linear range of chemical oxygen demand (COD) standard solution was 50-900mg/L, the linear correlation coefficient was 0.981, the recovery was 91% -106% and the relative standard deviation (RSD) was 6.7%. The rapid, accurate and precise method for detecting dyes showed an excellent promise for on-site and emergency detection in environment. At the request of the proceedings editor, an updated version of this article was published on 17 October 2017. The original version of this article was replaced due to an accidental inversion of Figure 2 and Figure 3. The Figures have been corrected in the updated and republished version.
40 CFR Appendix A to Subpart A of... - Switcher Locomotives
Code of Federal Regulations, 2010 CFR
2010-07-01
... 6-539. S11 6-539. S12 6-539T. S13 6-251C. RSD-1 6-539. RSC-13 6-539. RSC-24 12-244 RS1 6-539T. RS2 1 12-244. RS3 1 12-244. RS10 1 12-244. RSC-2 1 12-244. RS3 1 12-244. RSD-4 1 12-244. RSD-5 1 12-244. T6...
40 CFR Appendix A to Subpart A of... - Switcher Locomotives
Code of Federal Regulations, 2011 CFR
2011-07-01
... 6-539. S11 6-539. S12 6-539T. S13 6-251C. RSD-1 6-539. RSC-13 6-539. RSC-24 12-244 RS1 6-539T. RS2 1 12-244. RS3 1 12-244. RS10 1 12-244. RSC-2 1 12-244. RS3 1 12-244. RSD-4 1 12-244. RSD-5 1 12-244. T6...
40 CFR Appendix A to Subpart A of... - Switcher Locomotives
Code of Federal Regulations, 2013 CFR
2013-07-01
... 6-539. S11 6-539. S12 6-539T. S13 6-251C. RSD-1 6-539. RSC-13 6-539. RSC-24 12-244 RS1 6-539T. RS2 1 12-244. RS3 1 12-244. RS10 1 12-244. RSC-2 1 12-244. RS3 1 12-244. RSD-4 1 12-244. RSD-5 1 12-244. T6...
40 CFR Appendix A to Subpart A of... - Switcher Locomotives
Code of Federal Regulations, 2012 CFR
2012-07-01
... 6-539. S11 6-539. S12 6-539T. S13 6-251C. RSD-1 6-539. RSC-13 6-539. RSC-24 12-244 RS1 6-539T. RS2 1 12-244. RS3 1 12-244. RS10 1 12-244. RSC-2 1 12-244. RS3 1 12-244. RSD-4 1 12-244. RSD-5 1 12-244. T6...
40 CFR Appendix A to Subpart A of... - Switcher Locomotives
Code of Federal Regulations, 2014 CFR
2014-07-01
... 6-539. S11 6-539. S12 6-539T. S13 6-251C. RSD-1 6-539. RSC-13 6-539. RSC-24 12-244 RS1 6-539T. RS2 1 12-244. RS3 1 12-244. RS10 1 12-244. RSC-2 1 12-244. RS3 1 12-244. RSD-4 1 12-244. RSD-5 1 12-244. T6...
Quantification of the multi-streaming effect in redshift space distortion
NASA Astrophysics Data System (ADS)
Zheng, Yi; Zhang, Pengjie; Oh, Minji
2017-05-01
Both multi-streaming (random motion) and bulk motion cause the Finger-of-God (FoG) effect in redshift space distortion (RSD). We apply a direct measurement of the multi-streaming effect in RSD from simulations, proving that it induces an additional, non-negligible FoG damping to the redshift space density power spectrum. We show that, including the multi-streaming effect, the RSD modelling is significantly improved. We also provide a theoretical explanation based on halo model for the measured effect, including a fitting formula with one to two free parameters. The improved understanding of FoG helps break the fσ8-σv degeneracy in RSD cosmology, and has the potential of significantly improving cosmological constraints.
Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples
2014-02-01
2.274 3.657 10.06 14.56 30.36 35.93 % RSD : 15.87% 4.375% 2.931% 4.473% 3.349% 3.788% 2.802% 3.883% 3.449% RSD , relative standard deviation 9 Table...107.9% 106.4% Standard Deviation: 0.3171 0.3498 0.8024 2.964 4.526 10.06 13.83 16.38 11.81 % RSD : 5.657% 3.174% 3.035% 5.507% 4.332% 3.795% 2.626...119.1% 116.5% 109.4% 106.8% 105.2% 105.5% 105.8% 108.6% 107.8% Standard Deviation: 0.2379 0.5595 1.173 2.375 2.798 5.973 11.79 15.10 30.54 % RSD
Park, Yong Sook; Nam, Taek Kyun
2017-03-01
We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tandon, Lav; Colletti, Lisa M.; Drake, Lawrence R.
This report discusses the process used to prove in the SRNL-Rev.2 coulometer for isotopic data analysis used in the special plutonium material project. In May of 2012, the PAR 173 coulometer system that had been the workhorse of the Plutonium Assay team since the early 1970s became inoperable. A new coulometer system had been purchased from Savannah River National Laboratory (SRNL) and installed in August of 2011. Due to funding issues the new system was not qualified at that time. Following the failure of the PAR 173, it became necessary to qualify the new system for use in Process 3401a,more » Plutonium Assay by Controlled Coulometry. A qualification plan similar to what is described in PQR -141a was followed. Experiments were performed to establish a statistical summary of the performance of the new system by monitoring the repetitive analysis of quality control sample, PEOL, and the assay of plutonium metals obtained from the Plutonium Exchange Program. The data for the experiments was acquired using work instructions ANC125 and ANC195. Figure 1 shows approximately 2 years of data for the PEOL material obtained using the PAR 173. The required acceptance criteria for the sample are that it returns the correct value for the quality control material of 88.00% within 2 sigma (95% Confidence Interval). It also must meet daily precision standards that are set from the historical data analysis of decades of data. The 2 sigma value that is currently used is 0.146 % as evaluated by the Statistical Science Group, CCS-6. The average value of the PEOL quality control material run in 10 separate days on the SRNL-03 coulometer is 87.98% with a relative standard deviation of 0.04 at the 95% Confidence interval. The date of data acquisition is between 5/23/2012 to 8/1/2012. The control samples are run every day experiments using the coulometer are carried out. It is also used to prove an instrument is in statistical control before any experiments are undertaken. The total number of replicate controls run with the new coulometer to date, is n=18. This value is identical to that calculated by the LANL statistical group for this material from data produced by the PAR 173 system over the period of October 2007 to May 2011. The final validation/verification test was to run a blind sample over multiple days. AAC participates in a plutonium exchange program which supplies blind Pu metal samples to the group on a regular basis. The Pu material supplied for this study was ran using the PAR 173 in the past and more recently with the new system. Table 1a contains the values determined through the use of the PAR 173 and Table 1b contains the values obtained with the new system. The Pu assay value obtained on the SRNL system is for paired analysis and had a value of 98.88+/-0.07% RSD at 95% CI. The Pu assay value (decay corrected to July 2012) of the material determined in prior measurements using the PAR173 is 99.05 +/- 0.06 % RSD at 95% CI. We believe that the instrument is adequate to meet the needs of the program.« less
Campos-Mañas, Marina Celia; Plaza-Bolaños, Patricia; Sánchez-Pérez, José Antonio; Malato, Sixto; Agüera, Ana
2017-07-21
It is well known that wastewater treatment plant (WWTP) effluents usually contain micropollutants such as pharmaceuticals (or their transformation products, TPs) or pesticides, which is a major issue when evaluating their possible reuse (e.g. for irrigation in agriculture). In search for an improved accuracy and simplicity, methods based on the direct injection of the sample (DI) represent a recent trend taking advantage of the increasing sensitivity of new mass spectrometry (MS) instruments. Thus, the present study shows the development and validation of a DI-based method by ultra-high-performance liquid chromatography quadrupole-linear ion trap analyser (UHPLC-QqLIT-MS/MS). The proposed method was applied to the monitoring of 115 organic microcontaminants (including pharmaceuticals, TPs and pesticides) at the ngL -1 /μgL -1 level in wastewater effluents from urban WWTPs. Sample pre-treatment was reduced to acetonitrile addition and filtration of the mixture previous to LC-MS analysis. Total analysis time was <15min. A subsequent validation protocol was carried out in treated WW (TWW), following indications of SANTE and Eurachem Guidelines. Linearity and matrix effect were evaluated in the range of 10-1000ngL -1 . 70% of the analytes showed a moderate matrix effect (≤25%). Trueness (expressed as recovery) and precision (calculated as relative standard deviation, RSD) were evaluated at four concentration levels (20, 50, 500 and 1000ngL -1 ) in TWW samples. The LODs ranged from 1 to 357ngL -1 and the LOQs from 10 to 500ngL -1 . 92% of the compounds showed limits of quantification ≤100ngL -1 . In most cases, mean recoveries were in the range 70-120%, and RSD values were ≤20%. The validated method was successfully applied to the analysis of 10 TWW samples, demonstrating the occurrence of 67 target compounds at concentration levels from 26705ngL -1 (4-aminoantipyrine) to 10ngL -1 (tebuconazole and bezafibrate). Copyright © 2017 Elsevier B.V. All rights reserved.
Guan, Wenna; Zhu, Tao; Wang, Yuejie; Zhang, Zhongyi; Jin, Zhao; Wang, Cong; Bai, Fali
2016-09-01
Hydrocarbons are widespread in cyanobacteria, and the biochemical synthetic pathways were recently identified. Intracellular fatty alka(e)nes of cyanobacteria have been detected by liquid-liquid extraction (LLE) coupled to gas chromatography-mass spectrometry (GC/MS). However, whether fatty alka(e)nes can be released to cyanobacterial culture media remains to be clarified. This work develops a sensitive method for analyzing the trace level of extracellular hydrocarbons in cyanobacterial culture media by head space solid-phase microextraction (HS-SPME) coupled to GC/MS. Headspace (HS) extraction mode using polydimethylsiloxane fiber to extract for 30min at 50°C was employed as the optimal extraction conditions. Five cyanobacterial fatty alka(e)nes analogs including pentadecene (C15:1), pentadecane (C15:0), heptadecene (C17:1), heptadecane (C17:0), nonadecane (C19:0) were analyzed, and the data obtained from HS-SPME-GC/MS method were quantified using internal standard peak area comparisons. Limits of detection (LOD), limits of quantitation (LOQ), linear dynamic range, precisions (RSD) and recovery for the analysis of extracellular fatty alka(e)nes of cyanobacteria by HS-SPME-GC/MS were evaluated. The LODs limits of detection (S/N = 3) varied from 10 to 21 ng L-1. The correlation coefficients (r) of the calibration curves ranged from 0.9873 to 0.9977 with a linearity from 0.1 to 50 μg L-1. The RSD values were ranging from 7.8 to 14.0% and from 4.0 to 8.8% at 1.0 μg L-1 and 10.0 μg L-1 standard solutions, respectively. Comparative analysis of extracellular fatty alka(e)nes in the culture media of model cyanobacteria Synechocystis sp. PCC 6803 demonstrated that sensitivity of HS-SPME-GC/MS method was significantly higher than LLE method. Finally, we found that heptadecane can be released into the culture media of Synechocystis sp. PCC 6803 at the later growth period. Copyright © 2016 Elsevier B.V. All rights reserved.
Soponar, Florin; Moţ, Augustin C; Sârbu, Costel
2010-01-01
A novel HPTLC method was developed for fast and simple quantitative determination of rutin in pharmaceutical preparations. The proposed method combines the advantages of HPTLC with the comfort and the convenience of digital processing of images. For the separation of rutin, silica gel with attached amino groups was used as the stationary phase and ethyl acetate-formic acid-methanol-water (10 + 0.9 + 1.1 + 1.7, v/v/v/v) as the mobile phase. The chromatographic plate was sprayed with 2-aminoethyldiphenyl borate solution for visual detection of the spots. For the construction of a three-dimensional chromatogram, Melanie 7.0 software was used together with an HP flatbed scanner that allowed capture of the images on chromatographic plates. The calibration curve was linear within the range of 0.95-4.78 microg/spot with an r value of 0.9984. The RSD for six replicates at three concentration levels was less than 3%, while the recovery was between 97.28 and 103.27%. The proposed method was found to be simple, precise, sensitive, and accurate and has been applied for the determination of rutin in two commercial drugs. The results were compared with the results of other techniques that generate bidimensional chromatograms and validated by UV-Vis spectrophotometry.
Olivares, David; Bravo, Manuel; Feldmann, Jorg; Raab, Andrea; Neaman, Alexander; Quiroz, Waldo
2012-01-01
A new method for antimony speciation in terrestrial edible vegetables (spinach, onions, and carrots) was developed using HPLC with hydride generation-atomic fluorescence spectrometry. Mechanical agitation and ultrasound were tested as extraction techniques. Different extraction reagents were evaluated and optimal conditions were determined using experimental design methodology, where EDTA (10 mmol/L, pH 2.5) was selected because this chelate solution produced the highest extraction yield and exhibited the best compatibility with the mobile phase. The results demonstrated that EDTA prevents oxidation of Sb(III) to Sb(V) and maintains the stability of antimony species during the entire analytical process. The LOD and precision (RSD values obtained) for Sb(V), Sb(III), and trimethyl Sb(V) were 0.08, 0.07, and 0.9 microg/L and 5.0, 5.2, and 4.7%, respectively, for a 100 microL sample volume. The application of this method to real samples allowed extraction of 50% of total antimony content from spinach, while antimony extracted from carrots and onion samples ranged between 50 and 60 and 54 and 70%, respectively. Only Sb(V) was detected in three roots (onion and spinach) that represented 60-70% of the total antimony in the extracts.
Determination of total procyanidins in selected chocolate and confectionery products using DMAC.
Payne, Mark J; Hurst, William Jeffrey; Stuart, David A; Ou, Boxin; Fan, Ellen; Ji, Hongping; Kou, Yan
2010-01-01
A simple, specific, high-throughput colorimetric method based on the reaction of 4-dimethylaminocinnamaldehyde (DMAC) with flavan-3-ols was developed to determine total procyanidins in selected cacao-based products. Extracts of defatted samples were dispensed into a 96-well plate and reacted with DMAC. The absorbance of the reaction products was measured at 640 nm and compared to commercially available procyanidin B2 as a standard. The use of the 96-well plates and a plate reader dramatically improved sample throughput. A standard protocol was established and used for further studies. The calibration was found to be linear from 1-100 ppm. The DMAC reagent reacted relatively specifically to (-)-epicatechin, (+)-catechin, epigallocatechin, gallocatechin, the gallates of catechin, epicatechin, gallocatechin, and epigallocatechin, oligomeric procyanidins of cocoa up to n=4, and A-type procyanidins. Little or no reaction occurred with cyanidins and representative compounds of phenolic acids, flavones, flavanones, flavonols, anthocyanidins, isoflavones, and stilbenes. Sample precision studies were carried out on 10 different test materials over several weeks, and yielded RSD values of 4.0 to 9.5%. The method was ring-tested in three laboratories using blinded test materials including cocoa beans, cocoa powder, chocolate liquor, dark chocolate, and milk chocolate. There was excellent agreement of the results between laboratories.
Zhao, Yong-Gang; Zhang, Yun; Wang, Feng-Lian; Zhou, Jian; Zhao, Qi-Ming; Zeng, Xiu-Qiong; Hu, Mei-Qin; Jin, Mi-Cong; Zhu, Yan
2018-08-01
The novel quaternary ammonium modified magnetic carboxyl-carbon nanotubes (QA-Mag-CCNTs) have been synthesised and characterized. QA-Mag-CCNTs were applied in magnetic dispersive solid phase extraction (Mag-dSPE) for preconcentration of perchlorate from tea leaves prior to liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) analysis. The Mag-dSPE procedure for preconcentration of perchlorate succeed in overcoming the flaw (containing target analyte randomly) of commercially available SPE cartridge. Under optimal conditions, the results showed higher extraction efficiency of QA-Mag-CCNTs, with recoveries between 85.2% and 107%. And the satisfactory precision with inter-day and intra-day RSD values were lower than 8.0%. Furthermore, QA-Mag-CCNTs were evaluated for reuse up to 20 times. The limit of quantification (LOQ) for perchlorate was 8.21 ng kg -1 . The developed method was successfully applied in tea leaves for food-safety risk monitoring in Zhejiang province, China. The results showed the concentrations of perchlorate in 229 out of 240 collected samples were in the range of 0.082-988 μg kg -1 . It was confirmed that QA-Mag-CCNTs were highly effective materials used for preconcentration of perchlorate. Copyright © 2018 Elsevier B.V. All rights reserved.
Godayol, Anna; Alonso, Mònica; Sanchez, Juan M; Anticó, Enriqueta
2013-03-01
A quantification method based on solid-phase microextraction followed by GC coupled to MS was developed for the determination of gas-liquid partition coefficients and for the air monitoring of a group of odour-causing compounds that had previously been found in wastewater samples including dimethyl disulphide, phenol, indole, skatole, octanal, nonanal, benzothiazole and some terpenes. Using a divinylbenzene/carboxen/polydimethylsiloxane fibre, adsorption kinetics have been studied to define an extraction time that would avoid coating saturation. It was found that for an extraction time of 10 min, external calibration could be performed in the range of 0.4-100 μg/m(3), with detection limits between 0.1 and 20 μg/m(3). Inter-day precision of the developed method was evaluated (n = 5) and RSD values between 12 and 24% were obtained for all compounds. The proposed method has been applied to the analysis of air samples surrounding a wastewater treatment plant in Catalonia (Spain). In all air samples evaluated, dimethyl disulphide, limonene and phenol were detected, and the first two were the compounds that showed the highest partition coefficients. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jaworska, Karolina; Krynitsky, Alexander J; Rader, Jeanne I
2012-01-01
Simultaneous separation of steviol and steviol glycosides is challenging because of differences in their polarity and chemical structure. In this study, simultaneous analysis of steviol and steviol glycosides was achieved by LC with UV detection using a mixed-mode RP weak anion exchange chromatography column. Steviol and seven steviol glycosides were analyzed on an Acclaim Mixed-Mode Wax-1 (Dionex) column with a linear gradient of deionized water adjusted to pH 3.00 with phosphoric acid and acetonitrile. The extraction was performed by sonicating dry plant material at 40 degreesC in acetonitrile-water (30 + 70, v/v). LOQ values (mg/g dry weight of plant material) were rebaudioside B, 0.50; steviol, 0.70, dulcoside A, 1.0; steviolbioside, 1.2; stevioside and rebaudioside C, 2.0; rebaudioside D, 3.3; and rebaudioside A, 5.0. The method demonstrated suitable performance for all analytes tested with respect to accuracy (mean recoveries 95-99%), intraday and interday precision for retention times (0.070-0.28% and 0.33-1.0% RSD, respectively), and linearity. The method was used to authenticate steviol glycosides in several samples of Stevia plant material as well as to quantitate steviol glycosides in dietary supplements containing Stevia.
Determination of astaxanthin in Haematococcus pluvialis by first-order derivative spectrophotometry.
Liu, Xiao Juan; Juan, Liu Xiao; Wu, Ying Hua; Hua, Wu Ying; Zhao, Li Chao; Chao, Zhao Li; Xiao, Su Yao; Yao, Xiao Su; Zhou, Ai Mei; Mei, Zhou Ai; Liu, Xin; Xin, Liu
2011-01-01
A highly selective, convenient, and precise method, first-order derivative spectrophotometry, was applied for the determination of astaxanthin in Haematococcus pluvialis. Ethyl acetate and ethanol (1:1, v/v) were found to be the best extraction solvent tested due to their high efficiency and low toxicity compared with nine other organic solvents. Astaxanthin coexisting with chlorophyll and beta-carotene was analyzed by first-order derivative spectrophotometry in order to optimize the conditions for the determination of astaxanthin. The results show that when detected at 432 nm, the interfering substances could be eliminated. The dynamic linear range was 2.0-8.0 microg/mL, with a correlation coefficient of 0.9916. The detection threshold was 0.41 microg/mL. The RSD for the determination of astaxanthin was in the range of 0.01-0.06%; the results of recovery test were 98.1-108.0%. The statistical analysis between first-order derivative spectrophotometry and HPLC by T-testing did not exceed their critical values, revealing no significant differences between these two methods. It was proved that first-order derivative spectrophotometry is a rapid and convenient method for the determination of astaxanthin in H. pluvialis that can eliminate the negative effect resulting from the coexistence of astaxanthin with chlorophyll and beta-carotene.
Rodríguez-Arias, Marta; Montagud-Romero, Sandra; Rubio-Araiz, Ana; Aguilar, María A; Martín-García, Elena; Cabrera, Roberto; Maldonado, Rafael; Porcu, Francesca; Colado, María Isabel; Miñarro, José
2017-01-01
Social stress in adulthood enhances cocaine self-administration, an effect that has been related with an increase in extracellular signal-regulated kinase and p38α mitogen-activated protein kinase phosphorylation. A detrimental effect of cocaine on blood-brain barrier (BBB) integrity has also been reported. This study evaluates the effects of repeated social defeat (RSD) during adolescence on the reinforcing and motivational effects of cocaine in adult mice and the changes induced by RSD on BBB permeability. Cocaine self-administration, conditioned place preference and quantitative analysis of claudin-5, laminin, collagen-IV and IgG immunoreactivity took place 3 weeks after RSD. Mice socially defeated during adolescence developed conditioned place preference and exhibited reinstated preference with a non-effective dose of cocaine (1 mg/kg). RSD mice needed significantly more sessions than control animals for the preference induced by 25 mg/kg of cocaine to be extinguished. However, acquisition of cocaine self-administration (0.5 mg/kg per injection) was delayed in the RSD group. Mice exposed to RSD displayed significant changes in BBB structure in adulthood, with a marked reduction in expression of the tight junction protein claudin-5 and an increase in basal laminin degradation (reflected by a decrease in laminin and collagen-IV expression) in the nucleus accumbens and hippocampus. The detrimental effect induced by cocaine (25 mg/kg) on collagen-IV expression in the hippocampus was more pronounced in RSD mice. In summary, our findings suggest that stress and cocaine can increase the long-term vulnerability of the brain to subsequent environmental insults as a consequence of a sustained disruption of the BBB. © 2015 Society for the Study of Addiction.
Howard, Charla L; Wallace, Chris; Abbas, James; Stokic, Dobrivoje S
2017-01-01
We developed and evaluated properties of a new measure of variability in stride length and cadence, termed residual standard deviation (RSD). To calculate RSD, stride length and cadence are regressed against velocity to derive the best fit line from which the variability (SD) of the distance between the actual and predicted data points is calculated. We examined construct, concurrent, and discriminative validity of RSD using dual-task paradigm in 14 below-knee prosthesis users and 13 age- and education-matched controls. Subjects walked first over an electronic walkway while performing separately a serial subtraction and backwards spelling task, and then at self-selected slow, normal, and fast speeds used to derive the best fit line for stride length and cadence against velocity. Construct validity was demonstrated by significantly greater increase in RSD during dual-task gait in prosthesis users than controls (group-by-condition interaction, stride length p=0.0006, cadence p=0.009). Concurrent validity was established against coefficient of variation (CV) by moderate-to-high correlations (r=0.50-0.87) between dual-task cost RSD and dual-task cost CV for both stride length and cadence in prosthesis users and controls. Discriminative validity was documented by the ability of dual-task cost calculated from RSD to effectively differentiate prosthesis users from controls (area under the receiver operating characteristic curve, stride length 0.863, p=0.001, cadence 0.808, p=0.007), which was better than the ability of dual-task cost CV (0.692, 0.648, respectively, not significant). These results validate RSD as a new measure of variability in below-knee prosthesis users. Future studies should include larger cohorts and other populations to ascertain its generalizability. Copyright © 2016 Elsevier B.V. All rights reserved.
Sharma, Umender K; Chatterji, Dipankar
2008-05-01
Anti-sigma factors Escherichia coli Rsd and bacteriophage T4 AsiA bind to the essential housekeeping sigma factor, sigma(70), of E. coli. Though both factors are known to interact with the C-terminal region of sigma(70), the physiological consequences of these interactions are very different. This study was undertaken for the purpose of deciphering the mechanisms by which E. coli Rsd and bacteriophage T4 AsiA inhibit or modulate the activity of E. coli RNA polymerase, which leads to the inhibition of E. coli cell growth to different amounts. It was found that AsiA is the more potent inhibitor of in vivo transcription and thus causes higher inhibition of E. coli cell growth. Measurements of affinity constants by surface plasmon resonance experiments showed that Rsd and AsiA bind to sigma(70) with similar affinity. Data obtained from in vivo and in vitro binding experiments clearly demonstrated that the major difference between AsiA and Rsd is the ability of AsiA to form a stable ternary complex with RNA polymerase. The binding patterns of AsiA and Rsd with sigma(70) studied by using the yeast two-hybrid system revealed that region 4 of sigma(70) is involved in binding to both of these anti-sigma factors; however, Rsd interacts with other regions of sigma(70) as well. Taken together, these results suggest that the higher inhibition of E. coli growth by AsiA expression is probably due to the ability of the AsiA protein to trap the holoenzyme RNA polymerase rather than its higher binding affinity to sigma(70).
Kiuchi, Márcio Galindo; Chen, Shaojie; Hoye, Neil Alexander; Pürerfellner, Helmut
2018-01-01
Atrial fibrillation (AF) commonly occurs in chronic kidney disease (CKD), occasioning adverse outcomes. Merging pulmonary vein isolation (PVI) and renal sympathetic denervation (RSD) may decrease the recurrence of AF in subjects with CKD and uncontrolled hypertension. We considered that RSD could reduce the recurrence of AF in patients with CKD by modulating sympathetic hyperactivity. We aimed to evaluate the impact of RSD or spironolactone 50 mg/day associated with PVI in reducing systolic blood pressure (BP), AF recurrence, and AF burden in patients with a history of paroxysmal AF and mild CKD. This was a single-center, prospective, longitudinal, randomized, double-blind study. The individuals were randomly divided into two groups (PVI + spironolactone, n = 36, and PVI + RSD, n = 33). All of them were followed for exactly 1 year to assess maintenance of sinus rhythm and to monitor the other variables. Ambulatory BP measurements were reduced in both groups and at the 12th month also differed between groups. Significantly more patients in the PVI + RSD (61%) than in the PVI + spironolactone group (36%) were AF-free at the 12th month of follow-up, P = 0.0242. Toward the end of the study, the mean AF burden was lower in the PVI + RSD group as compared to PVI + spironolactone group, at the 9th month: ∆ = - 10% (P < 0.0001), and at the 12th month: ∆ = - 12% (P < 0.0001), respectively. PVI + RSD is safe and appears to be superior to PVI + spironolactone in BP reduction, augmentation of AF event-free rate, reduction of AF burden, and improvement of renal function.
Sharma, Umender K.; Chatterji, Dipankar
2008-01-01
Anti-sigma factors Escherichia coli Rsd and bacteriophage T4 AsiA bind to the essential housekeeping sigma factor, σ70, of E. coli. Though both factors are known to interact with the C-terminal region of σ70, the physiological consequences of these interactions are very different. This study was undertaken for the purpose of deciphering the mechanisms by which E. coli Rsd and bacteriophage T4 AsiA inhibit or modulate the activity of E. coli RNA polymerase, which leads to the inhibition of E. coli cell growth to different amounts. It was found that AsiA is the more potent inhibitor of in vivo transcription and thus causes higher inhibition of E. coli cell growth. Measurements of affinity constants by surface plasmon resonance experiments showed that Rsd and AsiA bind to σ70 with similar affinity. Data obtained from in vivo and in vitro binding experiments clearly demonstrated that the major difference between AsiA and Rsd is the ability of AsiA to form a stable ternary complex with RNA polymerase. The binding patterns of AsiA and Rsd with σ70 studied by using the yeast two-hybrid system revealed that region 4 of σ70 is involved in binding to both of these anti-sigma factors; however, Rsd interacts with other regions of σ70 as well. Taken together, these results suggest that the higher inhibition of E. coli growth by AsiA expression is probably due to the ability of the AsiA protein to trap the holoenzyme RNA polymerase rather than its higher binding affinity to σ70. PMID:18359804
Zhao, Jun; Zhou, Xing; Jiang, Anqi; Fan, Juanzi; Lan, Tao; Zhang, Jinbo; Cai, Zucong
2018-06-21
Soil disinfestation is an important agricultural practice to conquer soil-borne diseases and thereby ensure crop productivity. Reductive soil disinfestation (RSD) had been developed as an environmentally friendly alternative to chemical soil disinfestation (CSD). However, the differences between CSD and RSD on soil-borne pathogen suppression and fungal community structure remain poorly understood. In this work, five treatments, i.e., untreated soil (CK), CSD with 0.5 t ha -1 dazomet (DZ), RSD with 10 t ha -1 ethanol (ET), 15 t ha -1 sugarcane bagasse (SB), and 15 t ha -1 bean dregs (BD), were performed to investigate their influences on disinfestation efficiency, fungal abundance, diversity, and community structure via quantitative PCR and high-throughput sequencing. RSD-related treatments, especially the BD treatment, effectively alleviated soil acidification and salinization. The fungal abundance and microbial activity considerably increased in the BD treatment and significantly declined in the DZ treatment as compared to the CK treatment. Moreover, both CSD and RSD-related treatments significantly inhibited the population of Fusarium oxysporum and the relative abundance of genus Fusarium. Fungal community structure was notably altered by CSD and RSD practices. Furthermore, both CSD and RSD harbored a distinct unique microbiome, with the DZ treatment dominated by the genus Mortierella and BD treatment predominated by the genera Zopfiella, Chaetomium, and Penicillium. Taken together, these results indicate that the BD treatment could considerably alleviate the soil deterioration, improve soil microbial activity, and reassemble a non-pathogen unique microbiome that have more disease-suppressive agents and thus might be a promising disinfestation practice to control soil-borne disease in monoculture system.
Krishnaiah, Ch; Vishnu Murthy, M; Kumar, Ramesh; Mukkanti, K
2011-03-25
A simple, sensitive and reproducible ultra performance liquid chromatography (UPLC) coupled with a photodiode array detector method was developed for the quantitative determination of olanzapine (OLN) in API and pharmaceutical dosage forms. The method is applicable to the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH 100-mm, 2.1-mm, and 1.7-μm C-18 columns, and the gradient eluted within a short runtime, i.e., within 10.0 min. The eluted compounds were monitored at 250 nm, the flow rate was 0.3 mL/min, and the column oven temperature was maintained at 27°C. The resolution of OLN and eight (potential, bi-products and degradation) impurities was greater than 2.0 for all pairs of components. The high correlation coefficient (r(2)>0.9991) values indicated clear correlations between the investigated compound concentrations and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the RSD, were less than 2.4%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method expressed as relative error was satisfactory. No interference was observed from concomitant substances normally added to the tablets. The drug was subjected to the International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness. Copyright © 2010 Elsevier B.V. All rights reserved.
Determination of cadmium in sediments by diluted HCI extraction and isotope dilution ICP-MS.
Terán-Baamonde, Javier; Soto-Ferreiro, Rosa-María; Carlosena, Alatzne; Andrade, José-Manuel; Prada, Darío
2018-08-15
Isotope dilution ICP-MS is proposed to measure the mass fraction of Cd extracted by diluted HCl in marine sediments, using a fast and simple extraction procedure based on ultrasonic probe agitation. The 111 Cd isotope was added before the extraction to achieve isotope equilibration with native Cd solubilized from the sample. The parameters affecting trueness and precision of isotope ratio measurements were evaluated carefully and subsequently corrected in order to minimize errors; they were: detector dead time, spectral interferences, mass discrimination factor and optimum sample/spike ratio. The mass fraction of Cd extracted was compared with the sum of the certified contents of the three steps of the sequential extraction procedure of the Standards, Measurements and Testing Programme (SM&T) analysing the BCR 701 sediment to validate the method. The certified and measured values agreed, giving a measured / certified mass fraction ratio of 1.05. Further, the extraction procedure itself was studied by adding the enriched isotope after the extraction step, which allowed verifying that analyte losses occurred during this process. Two additional reference sediments with certified total cadmium contents were also analysed. The method provided very good precision (0.9%, RSD) and a low detection limit, 1.8 ng g -1 . The procedural uncertainty budget was estimated following the EURACHEM Guide by means of the 'GUM Workbench' software, obtaining a relative expanded uncertainty of 1.5%. The procedure was applied to determine the bioaccessible mass fraction of Cd in sediments from two environmentally and economically important areas of Galicia (rias of Arousa and Vigo, NW of Spain). Copyright © 2018 Elsevier B.V. All rights reserved.
Liu, Congmin; Dou, Xiaowen; Zhang, Lei; Li, Qian; Qin, Jia'an; Duan, Yaping; Yang, Meihua
2018-01-01
A rapid, sensitive, and reliable ultra-fast liquid chromatography combined with electrospray ionization tandem mass spectrometry (UFLC-ESI-MS/MS) method was established and applied to simultaneous determination of 31 triazine herbicides and their metabolites in multiple medicinal parts of traditional Chinese medicines (TCMs). A streamlined pretreatment approach using one-step extraction and dilution was proposed, which provided high-throughput processing, excellent recovery, and negligible interference. Afterwards, multiple-reaction monitoring (MRM) and information-dependent acquisition (IDA) triggered enhanced product ion spectra (EPI) was adopted to identify and quantify the targets in a single analysis. The optimized method was then validated according to the guidelines of the European Commission for the following parameters: Matrix effects, specificity, accuracy, precision, linearity, range, and stability. The LOD and LOQ for the 31 triazine herbicides were 0.1-10 μg kg -1 and 0.5-25 μg kg -1 , respectively. Recoveries at three concentration levels were within 67.9-120.3% with an associated precision RSD <20%. Using the proposed approach, trazines herbicides were determined from 44 commercially available TCMs. The detection rate of triazine herbicides residues was 15.9% of the total samples. Among them, atrazine, simeton, and simetryn were found in the radix, herba, and seed TCMs with values far below the referenced maximum residue limits (MRLs), but no residues were detected in either the flos or fructus. Taken together, this method has the potential to provide a means for triazines screening in extensive matrices, thereby laying the foundation for pesticide registration on TCMs. Moreover, it has the potential to guide further triazine residue control in TCMs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ruiz-Delgado, Ana; Arrebola-Liébanas, Francisco Javier; Romero-González, Roberto; López-Ruiz, Rosalía; Garrido Frenich, Antonia
2016-10-01
A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO 2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R 2 > 0.98) within the tested range (1-50 ng l -1 ). Recoveries were evaluated at three different levels (1, 5 and 50 ng l -1 ) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l -1 , which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l -1 .
Oliveira, Hugo M; Segundo, Marcela A; Lima, José L F C; Miró, Manuel; Cerdà, Victor
2010-05-01
In the present work, it is proposed, for the first time, an on-line automatic renewable molecularly imprinted solid-phase extraction (MISPE) protocol for sample preparation prior to liquid chromatographic analysis. The automatic microscale procedure was based on the bead injection (BI) concept under the lab-on-valve (LOV) format, using a multisyringe burette as propulsion unit for handling solutions and suspensions. A high precision on handling the suspensions containing irregularly shaped molecularly imprinted polymer (MIP) particles was attained, enabling the use of commercial MIP as renewable sorbent. The features of the proposed BI-LOV manifold also allowed a strict control of the different steps within the extraction protocol, which are essential for promoting selective interactions in the cavities of the MIP. By using this on-line method, it was possible to extract and quantify riboflavin from different foodstuff samples in the range between 0.450 and 5.00 mg L(-1) after processing 1,000 microL of sample (infant milk, pig liver extract, and energy drink) without any prior treatment. For milk samples, LOD and LOQ values were 0.05 and 0.17 mg L(-1), respectively. The method was successfully applied to the analysis of two certified reference materials (NIST 1846 and BCR 487) with high precision (RSD < 5.5%). Considering the downscale and simplification of the sample preparation protocol and the simultaneous performance of extraction and chromatographic assays, a cost-effective and enhanced throughput (six determinations per hour) methodology for determination of riboflavin in foodstuff samples is deployed here.
Chamkouri, Narges; Niazi, Ali; Zare-Shahabadi, Vali
2016-03-05
A novel pH optical sensor was prepared by immobilizing an azo dye called Janus Green B on the triacetylcellulose membrane. Condition of the dye solution used in the immobilization step, including concentration of the dye, pH, and duration were considered and optimized using the Box-Behnken design. The proposed sensor showed good behavior and precision (RSD<5%) in the pH range of 2.0-10.0. Advantages of this optical sensor include on-line applicability, no leakage, long-term stability (more than 6 months), fast response time (less than 1 min), high selectivity and sensitivity as well as good reversibility and reproducibility. Copyright © 2015. Published by Elsevier B.V.
Khodadoust, Saeid; Kouri, Narges Cham; Talebiyanpoor, Mohammad Sharif; Deris, Jamile; Pebdani, Arezou Amiri
2015-12-01
In this work a simple, inexpensive, and sensitive optical sensor based on triacetylcellulose membrane as solid support was developed by using immobilization of Giemsa indicator for pH measurement. In this method, the influence variables on the membrane performance including pH concentration of indicator, response time, ionic strength, and reversibility were investigated. At optimum values of all variables the response of optical pH sensor is linear in the pH range of 3.0-12.0. This optical sensor was produced through simultaneous binding of the Giemsa on the activated triacetylcellulose membrane which responded to the pH changes in a broader linear range within less than 2.0 min and suitable reproducibility (RSD<5%). Stability results showed that this sensor was stable after 6 months of storage in the water/ethanol (50:50, v/v) solution without any measurable divergence in response properties (less than 5% RSD). Copyright © 2015 Elsevier B.V. All rights reserved.
Pharmaceuticals in grocery market fish fillets by gas chromatography-mass spectrometry.
Mottaleb, Musavvir Arafat; Stowe, Carly; Johnson, Daniel R; Meziani, Mohammed J; Mottaleb, M Abdul
2016-01-01
Occurrences of pharmaceuticals are evident in aquatic organisms. A reproducible gas chromatography-mass spectrometry (GC-MS) method using selected ion monitoring (SIM) has been used to determine the anti-histamine diphenhydramine (DPH), anti-anxiety diazepam (DZP), anti-seizure carbamazepine (CZP) drugs and their metabolites in grocery stores fish that were homogenized, extracted, pre-concentrated, cleaned up, and examined. Identifications of the compounds in extracts were obtained by comparing similar mass spectral features and retention properties with standards. Among nine frequently detected drugs, only DPH and DZP were observed and ranged from 0.61 to 6.21 and 1.99 to 16.57 ng/g, respectively, in fourteen fish species. These concentration values were lower than the environmental fish. Mean spike recoveries of analytes exceeded 75% with relative standard deviations (RSD)<10%. The statistically-derived method detection limits (MDLs) for nine compounds ranged from 0.13 to 5.56 ng/g. Average surrogate recoveries were 80-85% with 4-9% RSD. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhu, Hong; Zhu, Jie; Wang, Lili; Li, Zaigui
2016-01-01
A solid-phase microextraction followed by gas chromatography-mass spectrometry method was developed to determine the volatile compounds in Shanxi aged vinegar. The optimal extraction conditions were: 50 °C for 20 min with a PDMS/DVB fiber. This analytical method was validated and showed satisfactory repeatability (0.5 %
Determination of volatile corrosion inhibitors by capillary electrophoresis.
Pereira, Elisabete A; Tavares, Marina F M
2004-10-08
In this work, a capillary electrophoresis (CE) method using indirect UV detection (214nm) for the simultaneous determination of monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), diethylethanolamine (DEEA), monocyclohexylamine (MCHA) and dicyclohexylamine (DCHA) in water/ethanol extracts of wrapping materials containing volatile corrosion inhibitors (VCIs) was described. A running buffer consisting of 0.010 molL(-1) imidazole, 0.010 molL(-1) 2-hydroxyisobutyric acid (HIBA) and 0.010 molL(-1) 18-crown-6 ether enabled separation of the analytes in less than 7 min. A few method validation parameters were determined revealing good migration time repeatability (<0.7% RSD) and area repeatability (< 1.8% RSD). Limits of detection were in the range of 0.52-1.54 mg L(-1). Recovery values were in the range of 94.8-100.9%. The methodology was successfully applied to the analysis of three commercial products (VCI treated paper, foam and plastic). The concentration of amines in these materials varied from 0.050 to 22.3% (w/w).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Lloyd A.
1996-10-17
The focus of this dissertation is the use of a twin quadrupole inductively coupled plasma mass spectrometer (ICP-MS) for the simultaneous detection of two m/z values. The twin quadrupole ICP-MS is used with laser ablation sample introduction in both the steady state (10 Hz) and single pulse modes. Steady state signals are highly correlated and the majority of flicker noise cancels when the ratio is calculated. Using a copper sample, the isotope ratio 63Cu +/ 65Cu + is measured with a relative standard deviation (RSD) of 0.26%. Transient signals for single laser pulses are also obtained. Copper isotope ratio measurementsmore » for several laser pulses are measured with an RSD of 0.85%. Laser ablation (LA) is used with steel samples to assess the ability of the twin quadrupole ICP-MS to eliminate flicker noise of minor components of steel samples. Isotopic and internal standard ratios are measured in the first part of this work. The isotope ratio 52Cr +/ 53Cr + (Cr present at 1.31 %) can be measured with an RSD of 0.06 % to 0.1 %. For internal standard elements, RSDs improve from 1.9 % in the Cr + signal to 0.12% for the ratio of 51V + to 52Cr +. In the second part of this work, one mass spectrometer is scanned while the second channel measures an individual m/z value. When the ratio of these two signals is calculated, the peak shapes in the mass spectrum are improved significantly. Pulses of analyte and matrix ions from individual drops are measured simultaneously using the twin quadrupole ICP-MS with monodisperse dried microparticulate injection (MDMI). At modest Pb concentrations (500 ppm), a shoulder on the leading edge of the Li + signal becomes apparent. Space charge effects are consistent with the disturbances seen.« less
Quantification of the multi-streaming effect in redshift space distortion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Yi; Oh, Minji; Zhang, Pengjie, E-mail: yizheng@kasi.re.kr, E-mail: zhangpj@sjtu.edu.cn, E-mail: minjioh@kasi.re.kr
Both multi-streaming (random motion) and bulk motion cause the Finger-of-God (FoG) effect in redshift space distortion (RSD). We apply a direct measurement of the multi-streaming effect in RSD from simulations, proving that it induces an additional, non-negligible FoG damping to the redshift space density power spectrum. We show that, including the multi-streaming effect, the RSD modelling is significantly improved. We also provide a theoretical explanation based on halo model for the measured effect, including a fitting formula with one to two free parameters. The improved understanding of FoG helps break the f σ{sub 8}−σ {sub v} degeneracy in RSD cosmology,more » and has the potential of significantly improving cosmological constraints.« less
Langevin equation with fluctuating diffusivity: A two-state model
NASA Astrophysics Data System (ADS)
Miyaguchi, Tomoshige; Akimoto, Takuma; Yamamoto, Eiji
2016-07-01
Recently, anomalous subdiffusion, aging, and scatter of the diffusion coefficient have been reported in many single-particle-tracking experiments, though the origins of these behaviors are still elusive. Here, as a model to describe such phenomena, we investigate a Langevin equation with diffusivity fluctuating between a fast and a slow state. Namely, the diffusivity follows a dichotomous stochastic process. We assume that the sojourn time distributions of these two states are given by power laws. It is shown that, for a nonequilibrium ensemble, the ensemble-averaged mean-square displacement (MSD) shows transient subdiffusion. In contrast, the time-averaged MSD shows normal diffusion, but an effective diffusion coefficient transiently shows aging behavior. The propagator is non-Gaussian for short time and converges to a Gaussian distribution in a long-time limit; this convergence to Gaussian is extremely slow for some parameter values. For equilibrium ensembles, both ensemble-averaged and time-averaged MSDs show only normal diffusion and thus we cannot detect any traces of the fluctuating diffusivity with these MSDs. Therefore, as an alternative approach to characterizing the fluctuating diffusivity, the relative standard deviation (RSD) of the time-averaged MSD is utilized and it is shown that the RSD exhibits slow relaxation as a signature of the long-time correlation in the fluctuating diffusivity. Furthermore, it is shown that the RSD is related to a non-Gaussian parameter of the propagator. To obtain these theoretical results, we develop a two-state renewal theory as an analytical tool.
Horčičiak, Michal; Masár, Marián; Bodor, Róbert; Danč, Ladislav; Bel, Peter
2012-03-01
A new method for the determination of trace glyphosate (GLYP), non-selective pesticide, by CZE with online ITP pre-treatment of drinking waters on a column-coupling (CC) chip has been developed. CC chip was equipped with two injection channels of 0.9 and 9.9 μL volumes, two separation channels of 9.3 μL total volume and a pair of conductivity detectors. A very effective ITP sample clean-up performed in the first channel at low pH (3.2) was introduced for quick CZE resolution and detection of GLYP carried out at higher pH (6.1) in the second channel on the CC chip. The LOD for GLYP was estimated at 2.5 μg/L (15 nmol/L) using a 9.9 |mL volume of the injection channel. ITP-CZE analyses of model and real samples have provided very favorable intra-day (0.1-1.2% RSD) and inter-day (2.9% RSD) repeatabilities of the migration time for GLYP while 0.2-6.9% RSD values were typical for the peak area data. Recoveries of GLYP in spiked drinking water varied in the range of 99-109%. A minimum pre-treatment of drinking water (degassing and dilution) and a short analysis time (ca. 10 min) were distinctive features of ITP-CZE determinations of GLYP on the CC chip with high sample volume loaded, as well. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Krachler, Michael; Rausch, Nicole; Feuerbacher, Helmut; Klemens, Patrick
2005-07-01
The use of a new HF-resistant tandem spray chamber arrangement consisting of a cyclonic spray chamber and a Scott-type spray chamber made from PFA and PEEK provides a straightforward approach for improving the performance of inductively coupled-mass spectrometry (ICP-MS). The characteristics of the tandem spray chamber were critically evaluated against a PEEK cyclonic and a PFA Scott-type spray chamber, respectively. Sensitivity across the entire mass range was increased by about three times compared to the conventional setup utilizing only one spray chamber. Precision of the results, especially at low signal intensities, improved by 160% and 31% compared to the cyclonic and Scott-type spray chamber, respectively. Using the tandem spray chamber, the oxide formation rate was lowered by about 50%. Signals as low as 30 counts could be determined under routine measurement conditions with a RSD of 2.4% thus allowing to precisely quantify small concentration differences at the ng l - 1 concentration level. The excellent precision (0.02-0.07%) of 206Pb / 207Pb and 206Pb / 208Pb ratios determined in pore water samples was rather limited by the instrumental capabilities of the single collector ICP-MS instrument than by the performance of the tandem spray chamber.
Neuroinflammatory Dynamics Underlie Memory Impairments after Repeated Social Defeat
McKim, Daniel B.; Niraula, Anzela; Tarr, Andrew J.; Wohleb, Eric S.
2016-01-01
Repeated social defeat (RSD) is a murine stressor that recapitulates key physiological, immunological, and behavioral alterations observed in humans exposed to chronic psychosocial stress. Psychosocial stress promotes prolonged behavioral adaptations that are associated with neuroinflammatory signaling and impaired neuroplasticity. Here, we show that RSD promoted hippocampal neuroinflammatory activation that was characterized by proinflammatory gene expression and by microglia activation and monocyte trafficking that was particularly pronounced within the caudal extent of the hippocampus. Because the hippocampus is a key area involved in neuroplasticity, behavior, and cognition, we hypothesize that stress-induced neuroinflammation impairs hippocampal neurogenesis and promotes cognitive and affective behavioral deficits. We show here that RSD caused transient impairments in spatial memory recall that resolved within 28 d. In assessment of neurogenesis, the number of proliferating neural progenitor cells (NPCs) and the number of young, developing neurons were not affected initially after RSD. Nonetheless, the neuronal differentiation of NPCs that proliferated during RSD was significantly impaired when examined 10 and 28 d later. In addition, social avoidance, a measure of depressive-like behavior associated with caudal hippocampal circuitry, persisted 28 d after RSD. Treatment with minocycline during RSD prevented both microglia activation and monocyte recruitment. Inhibition of this neuroinflammatory activation in turn prevented impairments in spatial memory after RSD but did not prevent deficits in neurogenesis nor did it prevent the persistence of social avoidance behavior. These findings show that neuroinflammatory activation after psychosocial stress impairs spatial memory performance independent of deficits in neurogenesis and social avoidance. SIGNIFICANCE STATEMENT Repeated exposure to stress alters the homeostatic environment of the brain, giving rise to various cognitive and mood disorders that impair everyday functioning and overall quality of life. The brain, previously thought of as an immune-privileged organ, is now known to communicate extensively with the peripheral immune system. This brain–body communication plays a significant role in various stress-induced inflammatory conditions, also characterized by psychological impairments. Findings from this study implicate neuroimmune activation rather than impaired neurogenesis in stress-induced cognitive deficits. This idea opens up possibilities for novel immune interventions in the treatment of cognitive and mood disturbances, while also adding to the complexity surrounding the functional implications of adult neurogenesis. PMID:26937001
Eydipour, Zainab; Vaezi, Gholamhassan; Nasehi, Mohammad; Haeri-Rouhani, Seyed-Ali; Zarrindast, Mohammad-Reza
2017-09-01
Serotonin receptors such as 5-HT3 plays critical role in regulation of sleep, wake cycle and cognitive process. Thus, we investigated the role of CA1 5HT3 serotonin receptors in memory acquisition deficit induced by total sleep deprivation (TSD; for 24 hour) and REM sleep deprivation (RSD; for 24 hour). Pain perception and locomotor activity were also assessed as factors that may affect the memory process. Modified water box and multi-platform apparatus were used to induce TSD or RSD, respectively. Passive avoidance, hot plate and open field devices were used for assessment of memory acquisition, pain and locomotor activity, respectively. Totally, 152 male Wistar rats were used in the study. Pre-training, intra-CA1 injection of 5-HT3 receptor agonist Chlorophenylbiguanide (Mchl; 0.01 and 0.001 µg/rat; P < 0.001) and antagonist Y-25130 (0.1 µg/rat; P < 0.001) reduced memory acquisition and did not alter pain response, while higher dose of both drugs increased locomotor activity in normal rats. Both TSD and RSD reduced memory acquisition (P < 0.001) and did not alter locomotor activity, while TSD (P < 0.001) but not RSD induced analgesia effect. The amnesia induced by TSD was restored by subthreshold dose of Y25130 (0.001 µg/rat; P < 0.001) but not Mchl (0.0001 µg/rat), while both drugs reversed TSD-induced analgesia effect (P < 0.01 for Mchl and P < 0.05 for Y25130), and Y25130 increased locomotor activity in TSD rats (P < 0.05). In RSD rats, subthreshold dose of both drugs did not alter memory acquisition deficit and increased locomotor activity (P < 0.001 for Mchl and P < 0.01 for Y25130), while the Y25130 (P < 0.001), but not Mchl induced analgesia in the RSD rats. Based on the above data, CA1 5HT3 receptors seem to play a critical role in cognitive and non-cognitive behaviors induced by TSD and RSD.
Kutluay, Aysegul; Aslanoglu, Mehmet
2014-08-11
Multi-walled carbon nanotubes (MWCNTs) functionalized by cobalt nanoparticles were obtained using a single step chemical deposition method in an ultrasonic bath. The composite material was characterized using scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). The electroactivity of the cobalt-functionalized MWCNTs was assessed in respect to the electrooxidation of paracetamol (PAR) and dopamine (DA). It was found that the carbon nanotube supported cobalt nanoparticles have significantly higher catalytic properties. The proposed electrode has been applied for the simultaneous determination of PAR and DA. The modified electrode could resolve the overlapped voltammetric waves of PAR and DA into two well-defined voltammetric peaks with peak to peak separation of about 203 mV. On the other hand, the presence of potential drug interfering compounds AA and UA did not affect the voltammetric responses of PAR and DA. The current of oxidation peaks showed a linear dependent on the concentrations of PAR and DA in the range of 5.2×10(-9)-4.5×10(-7) M (R(2)=0.9987) and 5.0×10(-8)-3.0×10(-6) M (R(2)=0.9999), respectively. The detection limits of 1.0×10(-9) M and 1.5×10(-8) M were obtained for PAR and DA, respectively. The proposed electrode showed good stability (peak current change: 4.9% with and RSD of 2.6% for PAR; 5.5% with and RSD of 3.0% for DA over 3 weeks), reproducibility (RSD 2.3% for PAR and RSD 1.5% for DA), repeatability (RSD 2.25% for PAR and RSD 2.50% for DA) and high recovery (99.7% with an RSD of 1.3% for PAR; 100.8% with an RSD of 1.8% for DA). The proposed method was successfully applied to the determination of PAR and DA in pharmaceuticals. Copyright © 2014. Published by Elsevier B.V.
Molecular mechanisms of repeated social defeat-induced glucocorticoid resistance: Role of microRNA.
Jung, Seung Ho; Wang, Yufen; Kim, Taewan; Tarr, Andrew; Reader, Brenda; Powell, Nicole; Sheridan, John F
2015-02-01
Glucocorticoid (GC) resistance is a severe problem associated with various inflammatory diseases. Previous studies have shown that repeated social stress induces GC resistance in innate immune cells, but the underlying molecular mechanisms have not been fully elucidated. Therefore, the purpose of this study was to examine potential underlying molecular mechanism(s) of repeated social defeat (RSD) stress on GC resistance in splenic macrophages. It was hypothesized that mRNA expression of receptors for GC and nuclear translocating-associated regulators in splenic macrophages would be affected by RSD, and that these changes would be associated with epigenetic modification. The data showed that the mRNA expression of GC and mineralocorticoid receptors were significantly decreased in splenic macrophages by RSD. RSD also induced a significantly decreased mRNA expression in FK506-binding protein 52 (FKBP52), consequently resulting in a significantly increased ratio of FKBP51 to FKBP52. Moreover, DNA methyltransferases 3a and 3b showed a significant decrease in their mRNA expression in the RSD group as did mRNA expression of histone deacetyltransferase 2. The RSD group also showed a significantly reduced quantity of methylated DNA in splenic macrophages. Based on microRNA (miRNA) profiling data, it was determined that RSD induced significantly increased expression of 9 different miRNAs that were predicted to interact with mRNAs of the GC receptor (6 miRNAs), mineralocorticoid receptor (3 miRNAs) and FKBP52 (2 miRNAs). Spearman correlation analysis revealed significantly strong correlations between the expression of 2 miRNAs and their target mRNA expression for GC receptors. Among these miRNAs, we verified direct effects of miRNA-29b and -340 overexpression on mRNA expression of GC receptors in L929 cells. The overexpression of miRNA-29b or -340 in L929 cells significantly reduced LPS-induced overexpression of GC receptors. In conclusion, this study provides evidence that epigenetic regulation, such as DNA methylation and miRNA expression, may play a role in the RSD-induced GC resistance that we have observed in splenic macrophages. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shedlock, Daniel; Dugan, Edward T.; Jacobs, Alan M.
X-ray backscatter radiography by selective detection (RSD) is a field tested and innovative approach to non-destructive evaluation (NDE). RSD is an enhanced single-side x-ray Compton backscatter imaging (CBI) technique which selectively detects scatter components to improve image contrast and quality. Scatter component selection is accomplished through a set of specially designed detectors with fixed and movable collimators. Experimental results have shown that this NDE technique can be used to detect boric acid deposition on a metallic plate through steel foil reflective insulation commonly covering reactor pressure vessels. The current system is capable of detecting boric acid deposits with sub-millimeter resolution,more » through such insulating materials. Industrial systems have been built for Lockheed Martin Space Co. and NASA. Currently the x-ray backscatter RSD scanning systems developed by the University of Florida are being used to inspect the spray-on foam insulation (SOFI) used on the external tank of the space shuttle. RSD inspection techniques have found subsurface cracking in the SOFI thought to be responsible for the foam debris which separated from the external tank during the last shuttle launch. These industrial scanning systems can be customized for many applications, and a smaller, lighter, more compact unit design is being developed. The smaller design is approximately four inches wide, three inches high, and about 12 inches in length. This smaller RSD system can be used for NDE of areas that cannot be reached with larger equipment. X-ray backscatter RSD is a proven technology that has been tested on a wide variety of materials and applications. Currently the system has been used to inspect materials such as aluminum, plastics, honeycomb laminates, reinforced carbon composites, steel, and titanium. The focus of RSD is for one-sided detection for applications where conventional non-destructive examination methods either will not work or give poor results. Acquired images have clearly shown, for a variety of conditions, that proper selection of x-ray field scatter components leads to a significant improvement in image quality and contrast. Improvements are significant enough in some cases that objects not visible to conventional CBI or transmission radiography become readily discernable with RSD. (authors)« less
Javad-Moosavi, Bibi-Zahra; Vaezi, Gholamhassan; Nasehi, Mohammad; Haeri-Rouhani, Seyed-Ali; Zarrindast, Mohammad-Reza
2017-10-03
Despite different theories regarding sleep physiological function, an overall census indicates that sleep is useful for neural plasticity which eventually strengthens cognition and brain performance. Different studies show that sleep deprivation (SD) leads to impaired learning and hippocampus dependent memory. According to some studies, cholinergic system plays an important role in sleep (particularly REM sleep), learning, memory, and its retrieval. So this study has been designed to investigate the effect of CA1 Cholinergic Muscarinic Receptors on memory acquisition deficit induced by total sleep deprivation (TSD) and REM sleep deprivation (RSD). A modified water box (locomotor activity may be provide a limiting factor in this method of SD) or multiple platforms were used for induction of TSD or RSD, respectively. Inhibitory passive avoidance apparatus has been used to determine the effects of SD and its changes by physostigmine (as cholinesterase inhibitor) or scopolamine (muscarinic receptor antagonist) on memory formation. Because locomotor activity and pain perception induce critical roles in passive avoidance memory formation, we also measured these factors by open field and hot-plate instruments, respectively. The results showed that TSD and RSD for 24 hours impaired memory formation but they did not alter locomotor activity. TSD also induced analgesia effect, but RSD did not alter it. Intra-CA1 injection of physostigmine (0.0001μg/rat) and scopolamine (0.01μg/rat) did not alter memory acquisition in the sham-TSD or sham-RSD, by themselves. Moreover, intra-CA1 injection of sub-threshold dose of physostigmine (0.0001μg/rat) and scopolamine (0.01μg/rat) could restore the memory acquisition deficit induced by RSD, while scopolamine could restore TSD-induced amnesia. Both drugs reversed analgesia induced by TSD. None of previous interventions altered locomotor activity. According to this study, CA1 cholinergic muscarinic receptors play an important role in amnesia induced by both TSD and RSD. However further studies are needed for showing cellular and molecular mechanisms of surprising result of similar pharmacological effects using compounds with opposite profiles. Copyright © 2016. Published by Elsevier Inc.
Molecular Mechanisms of Repeated Social Defeat-Induced Glucocorticoid Resistance: Role of microRNA
Jung, Seung Ho; Wang, Yufen; Kim, Taewan; Tarr, Andrew; Reader, Brenda; Powell, Nicole; Sheridan, John F.
2014-01-01
Glucocorticoid (GC) resistance is a severe problem associated with various inflammatory diseases. Previous studies have shown that repeated social stress induces GC resistance in innate immune cells, but the underlying molecular mechanisms have not been fully elucidated. Therefore, the purpose of this study was to examine potential underlying molecular mechanism(s) of repeated social defeat (RSD) stress on GC resistance in splenic macrophages. It was hypothesized that mRNA expression of receptors for GC and nuclear translocating-associated regulators in splenic macrophages would be affected by RSD, and that these changes would be associated with epigenetic modification. The data showed that the mRNA expression of GC and mineralocorticoid receptors were significantly decreased in splenic macrophages by RSD. RSD also induced a significantly decreased mRNA expression in FK506-binding protein 52 (FKBP52), consequently resulting in a significantly increased ratio of FKBP51 to FKBP52. Moreover, DNA methyltransferases 3a and 3b showed a significant decrease in their mRNA expression in the RSD group as did mRNA expression of histone deacetyltransferase 2. The RSD group also showed a significantly reduced quantity of methylated DNA in splenic macrophages. Based on microRNA (miRNA) profiling data, it was determined that RSD induced significantly increased expression of 9 different miRNAs that were predicted to interact with mRNAs of the GC receptor (6 miRNAs), mineralocorticoid receptor (3 miRNAs) and FKBP52 (2 miRNAs). Spearman correlation analysis revealed significantly strong correlations between the expression of 2 miRNAs and their target mRNA expression for GC receptors. Among these miRNAs, we verified direct effects of miRNA-29b and -340 overexpression on mRNA expression of GC receptors in L929 cells. The overexpression of miRNA-29b or -340 in L929 cells significantly reduced LPS-induced overexpression of GC receptors. In conclusion, this study provides evidence that epigenetic regulation, such as DNA methylation and miRNA expression, may play a role in the RSD-induced GC resistance that we have observed in splenic macrophages. PMID:25317829
NASA Astrophysics Data System (ADS)
Arain, Sadaf Sadia; Kazi, Tasneem Gul; Arain, Asma Jabeen; Afridi, Hassan Imran; Baig, Jameel Ahmed; Brahman, Kapil Dev; Naeemullah; Arain, Salma Aslam
2015-03-01
A new approach was developed for the preconcentration of cadmium (Cd) and nickel (Ni) in artificial saliva extract of dry snuff (brown and black) products using temperature-controlled ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (TIL-UDLLμE) followed by electrothermal atomic absorption spectrometry (ETAAS). The Cd and Ni were complexed with ammonium pyrrolidinedithiocarbamate (APDC), extracted in ionic liquid drops, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6]. The multivariate strategy was applied to estimate the optimum values of experimental variables influence the % recovery of analytes by TIL-UDLLμE method. At optimum experimental conditions, the limit of detection (3s) were 0.05 and 0.14 μg L-1 while relative standard deviations (% RSD) were 3.97 and 3.55 for Cd and Ni respectively. After extraction, the enhancement factors (EF) were 87 and 79 for Cd and Ni, respectively. The RSD for six replicates of 10 μg L-1 Cd and Ni were 3.97% and 3.55% respectively. To validate the proposed method, certified reference material (CRM) of Virginia tobacco leaves was analyzed, and the determined values of Cd and Ni were in good agreement with the certified values. The concentration of Cd and Ni in artificial saliva extracts corresponds to 39-52% and 21-32%, respectively, of the total contents of both elements in dry brown and black snuff products.
Fakhari, Ali Reza; Nojavan, Saeed; Haghgoo, Soheila; Mohammadi, Ali
2008-11-01
A simple, accurate, precise and sensitive method using CD for separation and stability indicating assay of enantiomers of amlodipine in the commercial tablets has been established. Several types of CD were evaluated and best results were obtained using a fused-silica capillary with phosphate running buffer (100 mM, pH 3.0) containing 5 mM hydroxypropyl-alpha-CD. The method has shown adequate separation for amlodipine enantiomers from its degradation products. The drug was subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The range of quantitation for both enantiomers was 5-150 microg/mL. Intra- and inter-day RSD (n=6) was <4%. The limit of quantification that produced the requisite precision and accuracy was found to be 5 microg/mL for both enantiomers. The LOD for both enantiomers was found to be 0.5 microg/mL. Degradation products produced as a result of stress studies did not interfere with the detection of enantiomers and the assay can thus be considered stability indicating.
NASA Astrophysics Data System (ADS)
Ibrahim, Maha M.; Elzanfaly, Eman S.; El-Zeiny, Mohamed B.; Ramadan, Nesreen K.; Kelani, Khadiga M.
2017-05-01
In this paper, three rapid, simple, accurate and precise spectrophotometric methods were developed for the determination of meclizine hydrochloride in the presence of pyridoxine hydrochloride without previous separation. The methods under study are dual wavelength (DWL), ratio difference (RD) and continuous wavelet transform (CWT). On the other hand, pyridoxine hydrochloride (PYH) was determined directly at 291 nm. The methods obey Beer's law in the range of (5-50 μg/mL) for both compounds. All the methods were validated according to the ICH guidelines where the accuracy was found to be 98.29, 99.59, 100.42 and 100.62% for DWL, RD, CWT and PYH; respectively. Moreover the precision of the methods were calculated in terms of %RSD and it was found to be 0.545, 0.372, 1.287 and 0.759 for DWL, RD,CWT and PYH; respectively. The selectivity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. So, they can be used for the routine analysis of pyridoxine hydrochloride and meclizine hydrochloride in quality-control laboratories.
D'Ambrosio, Michele
2013-06-15
γ-Oryzanol is an important phytochemical used in pharmaceutical, alimentary and cosmetic preparations. The present article, for the first time, discloses the performances of NP-HPLC in separating γ-oryzanol components and develops a validated method for its routine quantification. The analysis is performed on a cyanopropyl bonded column using the hexane/MTBE gradient elution and UV detection at 325 nm. The method allows: the separation of steryl ferulate, p-coumarate and caffeate esters, the separation of cis- from trans-ferulate isomers, the splitting of steroid moieties into saturated and unsaturated at the side chain. The optimised method provides excellent linear response (R(2)=0.99997), high precision (RSD<1.0%) and satisfactory accuracy (R(∗)=70-86%). In conclusion, the established method presents the details of the procedure and the experimental conditions in order to achieve the required precision and instrumental accuracy. The method is fast and sensitive and it could be a suitable tool for quality assurance and determination of origin. Copyright © 2012 Elsevier Ltd. All rights reserved.
Tao, Yi; Huang, Surun; Gu, Xianghui; Li, Weidong; Cai, Baochang
2018-05-30
Alkaline phosphatase conjugated magnetic microspheres were synthesized via amide reaction, and employed as an effective adsorbent in affinity selection of binding ligands followed by UHPLC-Q-TOF/MS analysis. The analytical validity of the developed approach was evaluated under optimized conditions and the following figures of merit were obtained: linearity, 0.01-0.5 g L -1 with good determination coefficients (R 2 = 0.9992); limits of detection (LODs), 0.003 g L -1 ; and limits of quantitation (LOQ), 0.01 g L -1 . The precision (RSD%) of the proposed affinity selection approach was studied based on intra-day (0.8%) and inter-day (1.3%) precisions. Finally, the adsorbent was successfully applied to identification of binding ligands in Li-Dan-Hua-Shi pills and good recoveries were obtained in the range from 96.9 to 99.4% (RSDs 1.6-3.0%). Copyright © 2018 Elsevier B.V. All rights reserved.
Chang, Le; Baseggio, Oscar; Sementa, Luca; Cheng, Daojian; Fronzoni, Giovanna; Toffoli, Daniele; Aprà, Edoardo; Stener, Mauro; Fortunelli, Alessandro
2018-06-13
We introduce Individual Component Maps of Rotatory Strength (ICM-RS) and Rotatory Strength Density (RSD) plots as analysis tools of chiro-optical linear response spectra deriving from time-dependent density functional theory (TDDFT) simulations. ICM-RS and RSD allow one to visualize the origin of chiro-optical response in momentum or real space, including signed contributions and therefore highlighting cancellation terms that are ubiquitous in chirality phenomena, and should be especially useful in analyzing the spectra of complex systems. As test cases, we use ICM-RS and RSD to analyze circular dichroism spectra of selected (Ag-Au)30(SR)18 monolayer-protected metal nanoclusters, showing the potential of the proposed tools to derive insight and understanding, and eventually rational design, in chiro-optical studies of complex systems.
Shehab, Dia; Elgazzar, Abdelhamid; Collier, B David; Naddaf, Sleiman; Al-Jarallah, Khalid; Omar, Abdelmoneim; Al-Mutairy, Moudi
2006-01-01
To determine the impact of three-phase bone scintigraphy (TPBS) on the diagnosis and management of complex regional pain syndrome type I (CRPSI) or reflex sympathetic dystrophy (RSD). Twenty consecutive patients with a recent clinical evidence of CRPSI were referred for TPBS as part of their routine management plan. All patients underwent neurological examinations with special attention to the evaluation of clinical features of vasomotor, sudomotor, motor and sensory dysfunction. Patients were followed prospectively. When both the clinical and TPBS results supported the diagnosis of CRPSI, patients were started on treatment. Of the 20 patients, TPBS supported the diagnosis of RSD in 9 who were treated with steroids and physiotherapy. Complete follow-up was available for 7 of them and all had a satisfactory response to treatment. For the remaining 11 patients RSD was diagnosed clinically but not confirmed by TPBS. On follow-up there was no evidence that TPBS failed to identify RSD in these 11 patients. The results indicate that TPBS confirmed the clinical diagnosis of RSD, and, more importantly, had a significant impact on its management.
Olszewska, Monika A
2012-09-01
An HPLC method of high resolution has been developed and validated for the simultaneous determination of ten prominent flavonoid aglycones in plant materials using a fused-core C18-silica column (Ascentis® Express, 4.6 mm × 150 mm, 2.7 μm). The separation was accomplished with an acetonitrile-tetrahydrofuran gradient elution at a flow rate of 1 mL/min and temperature of 30°C. UV spectrophotometric detection was employed at 370 nm for flavonols (quercetin [QU], myricetin [MY], isorhamnetin [IS], kaempferol [KA], sexangularetin [SX], and limocitrin [LM]) and 340 nm for flavones (apigenin [AP], acacetin [AC], chrysoeriol [CH], and luteolin [LU]). The high resolution of critical pairs QU/LU (10.50), QU/CH (3.40), AP/CH (2.51), SX/LM (2.30), and IS/KA (2.70) was achieved within 30.3 min. The observed column back pressure was less than 4300 psi, thus acceptable for conventional HPLC equipment. The method was sensitive enough having LODs of 0.115-0.525 ng and good linearity (r > 0.9999) over the test range. The precision values, expressed as RSD values, were <7.5%, and the accuracy was in the range of 95.3-100.2% for all analytes except MY (73.8%). The method was successfully employed for the determination of flavonoids in several medicinal plants, such as Ginkgo biloba, Betula pendula, and a variety of Sorbus species. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Souza, Israel D; Melo, Lidervan P; Jardim, Isabel C S F; Monteiro, Juliana C S; Nakano, Ana Marcia S; Queiroz, Maria Eugênia C
2016-08-17
A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL(-1) (LLOQ) to 400 ng mL(-1) with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from -1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Ying; Tobias, Herbert J.; Brenna, J. Thomas
2014-01-01
Comprehensive two dimensional gas chromatography (GC×GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC×GC fast quadrupole MS were investigated with electron ionization (EI), and CH4 or NH3 positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH3. The average limits of detection (LOD) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL−1 for EI, 1.3 ng mL−1 for PCI-CH4, and 0.3 ng mL−1 for PCI-NH3, all in mass scanning mode. The measured limits of quantification (LOQ) with full mass scan GC×GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in single ion monitoring (SIM) mode. PCI-NH3 yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH4. These data show a benchtop GC×GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH3, not currently available on most GC×GC-TOFMS instruments, is of particular value for generation of structure-specific ions. PMID:22606686
Arrebola-Liébanas, Francisco Javier; Abdo, María Angeles Herrera; Moreno, José Luis Fernandez; Martínez-Vidal, José L; Frenich, Antonia Garrido
2014-01-01
A simple and fast method has been developed for determining relevant quaternary ammonium compounds in cucumber and orange samples. The target compounds were benzoalkonium chloride (BAC-10, BAC-12, BAC-14, and BAC-16), didecyldimethylammonium chloride, and benzethonium chloride, all frequently used biocides in the agrifood industry. An extraction based on the buffered Quick, Easy, Cheap, Effective, Rugged, and Safe method and determination by ultra-performance LC/MS/MS that eluted the biocides in less than 5 min were used. The method was fully validated and implemented in a UNE-EN-ISO/IEC 17025 accredited laboratory for its application to the analysis of real samples. Performance characteristics of the method are reported, including an estimation of measurement uncertainty. Calibration curves were set between 0.01 and 0.150 mg/kg, LOD values were always between 0.4 and 1.0 microg/kg, LOQ values were in the range 1-4 microg/kg, recovery was between 81 and 115%, intraday and interday precision were always lower than 17% (expressed as RSD), and expanded uncertainty was always lower than 40%. The validation was accomplished for the two studied matrixes at spiking concentrations of 0.011 and 0.050 mg/kg. The method has been applied to the analysis of 30 cucumber and orange samples that were found to contain concentrations of BAC-12 that ranged between 0.015 and 0.210 mg/kg and of BAC-14 between 0.018 and 0.081 mg/kg.
Ramos, Inês I; Gregório, Bruno J R; Barreiros, Luísa; Magalhães, Luís M; Tóth, Ildikó V; Reis, Salette; Lima, José L F C; Segundo, Marcela A
2016-04-01
An automated oxygen radical absorbance capacity (ORAC) method based on programmable flow injection analysis was developed for the assessment of antioxidant reactivity. The method relies on real time spectrophotometric monitoring (540 nm) of pyrogallol red (PGR) bleaching mediated by peroxyl radicals in the presence of antioxidant compounds within the first minute of reaction, providing information about their initial reactivity against this type of radicals. The ORAC-PGR assay under programmable flow format affords a strict control of reaction conditions namely reagent mixing, temperature and reaction timing, which are critical parameters for in situ generation of peroxyl radical from 2,2'-azobis(2-amidinopropane) dihydrochloride (AAPH). The influence of reagent concentrations and programmable flow conditions on reaction development was studied, with application of 37.5 µM of PGR and 125 mM of AAPH in the flow cell, guaranteeing first order kinetics towards peroxyl radicals and pseudo-zero order towards PGR. Peroxyl-scavenging reactivity of antioxidants, bioactive compounds and phenolic-rich beverages was estimated employing the proposed methodology. Recovery assays using synthetic saliva provided values of 90 ± 5% for reduced glutathione. Detection limit calculated using the standard antioxidant compound Trolox was 8 μM. RSD values were <3.4 and <4.9%, for intra and inter-assay precision, respectively. Compared to previous batch automated ORAC assays, the developed system also accounted for high sampling frequency (29 h(-1)), low operating costs and low generation of waste. Copyright © 2015 Elsevier B.V. All rights reserved.
Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning
2011-07-01
The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.
Sawicki, C M; McKim, D B; Wohleb, E S; Jarrett, B L; Reader, B F; Norden, D M; Godbout, J P; Sheridan, J F
2015-08-27
Repeated social defeat (RSD) in mice causes myeloid cell trafficking to the brain that contributes to the development of prolonged anxiety-like behavior. Myeloid cell recruitment following RSD occurs in regions where neuronal and microglia activation is observed. Thus, we hypothesized that crosstalk between neurons, microglia, and endothelial cells contributes to brain myeloid cell trafficking via chemokine signaling and vascular adhesion molecules. Here we show that social defeat caused an exposure- and brain region-dependent increase in several key adhesion molecules and chemokines involved in the recruitment of myeloid cells. For example, RSD induced distinct patterns of adhesion molecule expression that may explain brain region-dependent myeloid cell trafficking. VCAM-1 and ICAM-1 mRNA expression were increased in an exposure-dependent manner. Furthermore, RSD-induced VCAM-1 and ICAM-1 protein expression were localized to the vasculature of brain regions implicated in fear and anxiety responses, which spatially corresponded to previously reported patterns of myeloid cell trafficking. Next, mRNA expression of additional adhesion molecules (E- and P-selectin, PECAM-1) and chemokines (CXCL1, CXCL2, CXCL12, CCL2) were determined in the brain. Social defeat induced an exposure-dependent increase in mRNA levels of E-selectin, CXCL1, and CXCL2 that increased with additional days of social defeat. While CXCL12 was unaffected by RSD, CCL2 expression was increased by six days of social defeat. Last, comparison between enriched CD11b(+) cells (microglia/macrophages) and enriched GLAST-1(+)/CD11b(-) cells (astrocytes) revealed RSD increased mRNA expression of IL-1β, CCL2, and CXCL2 in microglia/macrophages but not in astrocytes. Collectively, these data indicate that key mediators of leukocyte recruitment were increased in the brain vasculature following RSD in an exposure- and brain region-dependent manner. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Wohleb, Eric S.; Patterson, Jenna M.; Sharma, Vikram; Quan, Ning
2014-01-01
Interleukin-1β (IL-1β) is an inflammatory cytokine that plays a prominent role in stress-induced behavioral changes. In a model of repeated social defeat (RSD), elevated IL-1β expression in the brain was associated with recruitment of primed macrophages that were necessary for development of anxiety-like behavior. Moreover, microglia activation and anxiety-like behavior associated with RSD did not occur in IL-1 receptor type-1 knock-out (IL-1R1KO) mice. Therefore, the objective of this study was to examine the role of IL-1 signaling in RSD-induced macrophage trafficking to the brain and anxiety-like behavior. Initial studies revealed that RSD did not increase circulating myeloid cells in IL-1R1KO mice, resulting in limited macrophage trafficking to the brain. In addition, IL-1R1KO bone marrow-chimera mice showed that IL-1R1 expression was essential for macrophage trafficking into the brain. To differentiate cellular mediators of stress-induced IL-1 signaling, endothelial-specific IL-1R1 knock-down (eIL-1R1kd) mice were used. Both wild-type (WT) and eIL-1R1kd mice had increased circulating monocytes, recruitment of macrophages to the brain, and altered microglia activation after RSD. Nonetheless, RSD-induced expression of IL-1β, TNF-α, and IL-6 mRNA in brain CD11b+ cells was attenuated in eIL-1R1kd mice compared with WT. Moreover, anxiety-like behavior did not develop in eIL-1R1kd mice. Collectively, these findings demonstrated that there was limited RSD-induced priming of myeloid cells in IL-1R1KO mice and disrupted propagation of neuroinflammatory signals in the brain of eIL-1R1kd mice. Furthermore, these data showed that transduction of IL-1 signaling by endothelial cells potentiates stress-induced neuroinflammation and promotes anxiety-like behavior. PMID:24523548
Yao, Wei; Wang, Neng; Qian, Jin; Bai, Lu; Zheng, Xiaoxin; Hou, Guo; Qiu, Xuan; Yang, Bo
2017-11-01
Chronic congestive heart failure (CHF) is the end outcome of organic heart diseases and one of the major diseases harmful to human health. Renal sympathetic denervation (RSD) is the anatomical basis of transcatheter renal sympathetic nerve ablation within the renal artery. To date, the roles of norepinephrine and angiotensin II (Ang II) in myocardial apoptosis and their underlying mechanisms have not been well explored. The aim of the present study was to verify the hypothesis that RSD is likely to inhibit myocardial apoptosis by inhibiting the release of norepinephrine and Ang II. An isoproterenol-induced CHF rat model was established, and the effects of RSD on myocardial apoptosis were examined using flow cytometry and TUNEL staining. The expression of factors associated with myocardial apoptosis, including p53, tumor necrosis factor-α (TNF-α), nuclear factor-κB (NF-κB), caspase-2 and -3, were measured using quantitative polymerase chain reaction and western blot analysis. The results indicated that the mRNA levels of p53, TNF-α, NF-κB, caspase-2 and -3 were significantly reduced in the myocardial tissues of rats in the CHF+RSD group when compared with the levels in the CHF+sham group (P<0.01 for all). In addition, the protein levels of p53, TNF-α, NF-κB and caspases-2 and -3 were decreased by 42.6, 41.3, 46.7, 30.0 and 35.8%, respectively, in myocardial tissues of rats in the CHF+RSD group in comparison with the CHF+sham group (P<0.01 for all). Furthermore, myocardial apoptosis was improved in rats in the CHF+RSD group compared with that in the CHF+sham group (P<0.01). In conclusion, the present study provides a theoretical basis for application of RSD in the treatment of CHF.
Yao, Wei; Wang, Neng; Qian, Jin; Bai, Lu; Zheng, Xiaoxin; Hou, Guo; Qiu, Xuan; Yang, Bo
2017-01-01
Chronic congestive heart failure (CHF) is the end outcome of organic heart diseases and one of the major diseases harmful to human health. Renal sympathetic denervation (RSD) is the anatomical basis of transcatheter renal sympathetic nerve ablation within the renal artery. To date, the roles of norepinephrine and angiotensin II (Ang II) in myocardial apoptosis and their underlying mechanisms have not been well explored. The aim of the present study was to verify the hypothesis that RSD is likely to inhibit myocardial apoptosis by inhibiting the release of norepinephrine and Ang II. An isoproterenol-induced CHF rat model was established, and the effects of RSD on myocardial apoptosis were examined using flow cytometry and TUNEL staining. The expression of factors associated with myocardial apoptosis, including p53, tumor necrosis factor-α (TNF-α), nuclear factor-κB (NF-κB), caspase-2 and −3, were measured using quantitative polymerase chain reaction and western blot analysis. The results indicated that the mRNA levels of p53, TNF-α, NF-κB, caspase-2 and −3 were significantly reduced in the myocardial tissues of rats in the CHF+RSD group when compared with the levels in the CHF+sham group (P<0.01 for all). In addition, the protein levels of p53, TNF-α, NF-κB and caspases-2 and −3 were decreased by 42.6, 41.3, 46.7, 30.0 and 35.8%, respectively, in myocardial tissues of rats in the CHF+RSD group in comparison with the CHF+sham group (P<0.01 for all). Furthermore, myocardial apoptosis was improved in rats in the CHF+RSD group compared with that in the CHF+sham group (P<0.01). In conclusion, the present study provides a theoretical basis for application of RSD in the treatment of CHF. PMID:29104628
Sawicki, Caroline M.; McKim, Daniel B.; Wohleb, Eric S.; Jarrett, Brant L.; Reader, Brenda F.; Norden, Diana M.; Godbout, Jonathan P.; Sheridan, John F.
2014-01-01
Repeated social defeat (RSD) in mice causes myeloid cell trafficking to the brain that contributes to the development of prolonged anxiety-like behavior. Myeloid cell recruitment following RSD occurs in regions where neuronal and microglia activation is observed. Thus, we hypothesized that crosstalk between neurons, microglia, and endothelial cells contributes to brain-myeloid cell trafficking via chemokine signaling and vascular adhesion molecules. Here we show that social defeat caused an exposure- and brain region-dependent increase in several key adhesion molecules and chemokines involved in the recruitment of myeloid cells. For example, RSD induced distinct patterns of adhesion molecule expression that may explain brain region-dependent myeloid cell trafficking. VCAM-1 and ICAM-1 mRNA expression were increased in an exposure-dependent manner. Furthermore, RSD-induced VCAM-1 and ICAM-1 protein expression were localized to the vasculature of brain regions implicated in fear and anxiety responses, which spatially corresponded to previously reported patterns of myeloid cell trafficking. Next, mRNA expression of additional adhesion molecules (E- and P-selectin, PECAM-1) and chemokines (CXCL1, CXCL2, CXCL12, CCL2) were determined in the brain. Social defeat induced an exposure-dependent increase in mRNA levels of E-selectin, CXCL1, and CXCL2 that increased with additional days of social defeat. While CXCL12 was unaffected by RSD, CCL2 expression was increased by six days of social defeat. Last, comparison between enriched CD11b+ cells (microglia/macrophages) and enriched GLAST-1+/CD11b− cells (astrocytes) revealed RSD increased mRNA expression of IL-1β, CCL2, and CXCL2 in microglia/macrophages but not in astrocytes. Collectively, these data indicate that key mediators of leukocyte recruitment were increased in the brain vasculature following RSD in an exposure- and brain-region dependent manner. PMID:25445193
Takach, Edward; O'Shea, Thomas; Liu, Hanlan
2014-08-01
Quantifying amino acids in biological matrices is typically performed using liquid chromatography (LC) coupled with fluorescent detection (FLD), requiring both derivatization and complete baseline separation of all amino acids. Due to its high specificity and sensitivity, the use of UPLC-MS/MS eliminates the derivatization step and allows for overlapping amino acid retention times thereby shortening the analysis time. Furthermore, combining UPLC-MS/MS with stable isotope labeling (e.g., isobaric tag for relative and absolute quantitation, i.e., iTRAQ) of amino acids enables quantitation while maintaining sensitivity, selectivity and speed of analysis. In this study, we report combining UPLC-MS/MS analysis with iTRAQ labeling of amino acids resulting in the elution and quantitation of 44 amino acids within 5 min demonstrating the speed and convenience of this assay over established approaches. This chromatographic analysis time represented a 5-fold improvement over the conventional HPLC-MS/MS method developed in our laboratory. In addition, the UPLC-MS/MS method demonstrated improvements in both specificity and sensitivity without loss of precision. In comparing UPLC-MS/MS and HPLC-MS/MS results of 32 detected amino acids, only 2 amino acids exhibited imprecision (RSD) >15% using UPLC-MS/MS, while 9 amino acids exhibited RSD >15% using HPLC-MS/MS. Evaluating intra- and inter-assay precision over 3 days, the quantitation range for 32 detected amino acids in rat plasma was 0.90-497 μM, with overall mean intra-day precision of less than 15% and mean inter-day precision of 12%. This UPLC-MS/MS assay was successfully implemented for the quantitative analysis of amino acids in rat and mouse plasma, along with mouse urine and tissue samples, resulting in the following concentration ranges: 0.98-431 μM in mouse plasma for 32 detected amino acids; 0.62-443 μM in rat plasma for 32 detected amino acids; 0.44-8590μM in mouse liver for 33 detected amino acids; 0.61-1241 μM in mouse kidney for 37 detected amino acids; and 1.39-1,681 μM in rat urine for 34 detected amino acids. The utility of the assay was further demonstrated by measuring and comparing plasma amino acid levels between pre-diabetic Zucker diabetic fatty rats (ZDF/Gmi fa/fa) and their lean littermates (ZDF/Gmi fa/?). Significant differences (P<0.001) in 9 amino acid concentrations were observed, with the majority ranging from a 2- to 5-fold increase in pre-diabetic ZDF rats on comparison with ZDF lean rats, consistent with previous literature reports. Copyright © 2014 Elsevier B.V. All rights reserved.
ASD-RSD; To Merge or Not to Merge
ERIC Educational Resources Information Center
Sinclair, Dorothy
1971-01-01
This paper clarifies the history of the proposal, and comments on some of the issues involved in the merger of the Reference Services Division (RSD) and the Adult Services Division (ASD) of the American Library Association. (MF)
Sensitivity of geographic information system outputs to errors in remotely sensed data
NASA Technical Reports Server (NTRS)
Ramapriyan, H. K.; Boyd, R. K.; Gunther, F. J.; Lu, Y. C.
1981-01-01
The sensitivity of the outputs of a geographic information system (GIS) to errors in inputs derived from remotely sensed data (RSD) is investigated using a suitability model with per-cell decisions and a gridded geographic data base whose cells are larger than the RSD pixels. The process of preparing RSD as input to a GIS is analyzed, and the errors associated with classification and registration are examined. In the case of the model considered, it is found that the errors caused during classification and registration are partially compensated by the aggregation of pixels. The compensation is quantified by means of an analytical model, a Monte Carlo simulation, and experiments with Landsat data. The results show that error reductions of the order of 50% occur because of aggregation when 25 pixels of RSD are used per cell in the geographic data base.
Liu, Xiaofei; Ying, Guangyao; Sun, Chaonan; Yang, Meihua; Zhang, Lei; Zhang, Shanshan; Xing, Xiaoyan; Li, Qian; Kong, Weijun
2018-01-01
The high acidity and complex components of Hibiscus sabdariffa have provided major challenges for sensitive determination of trace aflatoxins. In this study, sample pretreatment of H. sabdariffa was systematically developed for sensitive high performance liquid chromatography-fluorescence detection (HPLC-FLD) after ultrasonication-assisted extraction, immunoaffinity column (IAC) clean-up and on-line post-column photochemical derivatization (PCD). Aflatoxins B1, B2, G1, G2 were extracted from samples by using methanol/water (70:30, v/v) with the addition of NaCl. The solutions were diluted 1:8 with 0.1 M phosphate buffer (pH 8.0) to negate the issues of high acidity and matrix interferences. The established method was validated with satisfactory linearity (R > 0.999), sensitivity (limits of detection (LODs) and limits of quantitation (LOQs) of 0.15–0.65 and 0.53–2.18 μg/kg, respectively), precision (RSD <11%), stability (RSD of 0.2–3.6%), and accuracy (recovery rates of 86.0–102.3%), which all met the stipulated analytical requirements. Analysis of 28 H. sabdariffa samples indicated that one sample incubated with Aspergillus flavus was positive with aflatoxin B1 (AFB1) at 3.11 μg/kg. The strategy developed in this study also has the potential to reliably extract and sensitively detect more mycotoxins in other complex acidic matrices, such as traditional Chinese medicines, foodstuffs, etc. PMID:29681848
Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Suo, Hao; Sun, Baoshan
2017-11-15
Vidal Blanc grape (Vitis vinifera cv.) is the predominant white grape variety used for the production of icewine in China's Liaoning province. In this paper, the development and validation of the method by ultrahigh-performance liquid chromatography-tandem mass spectrometry has been performed for determination of the detailed phenolic composition in the skin, seed and stem of Vidal grapes. The validation of the method was realized by calculating the linearity, repeatability, precision, stability and the limits of detection (LOD) and quantification (LOQ) of standard solutions. All the curves exhibited good linearity (r 2 >0.9997) and the LOD and LOQ were in the range of 0.002-0.025 and 0.006-0.086μg/ml, respectively. Good repeatability (RSD<4.3%) and stability (RSD<3.7%) were also found. Results confirmed that the developed method was more effective and sensitive for simultaneous determination of the major phenolic compounds in Vidal grape pomace. The optimized and validated method of ultrahigh-performance liquid chromatography tandem two complementary techniques, fourier transform ion cyclotron resonance mass spectrometry and triple-quadrupole mass spectrometry, allowed to identify and quantify up to 35 phenolic compounds in Vidal grape pomace, which has, as far as we know, been reported this grapevine variety for the first time. Seeds, skins and stems exhibited different qualitative and quantitative phenolic profiles. These results provided useful information for recovery of phenolic antioxidants from different parts of icewine pomace. Copyright © 2017. Published by Elsevier B.V.
Gielecińska, Iwona; Mojska, Hanna
2013-01-01
Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3-d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 microg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery - 97.4%). Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.
Bio-assay guided isolation of α-glucosidase inhibitory constituents from Hibiscus mutabilis leaves.
Kumar, Deepak; Kumar, Hemanth; Vedasiromoni, J R; Pal, Bikas C
2012-01-01
The increasing demand for natural-product-based medicines and health-care products for the management of diabetes encouraged investigation of this commonly available Indian plant. To establish the anti-diabetic (α-glucosidase inhibitory) activity of H. mutabilis leaf extract, isolate and identify the constituents responsible for the activity, and validate a HPLC method for quantification of the active constituents for standardisation of the extract. The methanolic extract of leaves was partitioned between water, n-butanol and ethyl acetate. Bio-assay guided fractionation, based on inhibition of α-glucosidase, allowed isolation and identification of the active components. The active components were quantified using RP-HPLC-DAD validated for linearity, limit of detection, limit of quantification, precision, accuracy and robustness for this plant extract and the partitioned fractions. Ferulic acid and caffeic acid were identified as the α-glucosidase inhibitors present in H. mutabilis. They were partitioned into an ethyl acetate fraction. The HPLC-DAD calibration curve showed good linearity (r² > 0.99). For the recovery studies the %RSD was less than 2%. The interday and intraday variations were found to be less than 4% RSD for retention time and response. The identification of α-glucosidase inhibition activity in H. mutabilis supports further investigations into the possible use of the plant for the management of diabetes. The HPLC method validated for these extracts will be useful in future research with the plant. Copyright © 2011 John Wiley & Sons, Ltd.
Liu, Xiaofei; Ying, Guangyao; Sun, Chaonan; Yang, Meihua; Zhang, Lei; Zhang, Shanshan; Xing, Xiaoyan; Li, Qian; Kong, Weijun
2018-01-01
The high acidity and complex components of Hibiscus sabdariffa have provided major challenges for sensitive determination of trace aflatoxins. In this study, sample pretreatment of H. sabdariffa was systematically developed for sensitive high performance liquid chromatography-fluorescence detection (HPLC-FLD) after ultrasonication-assisted extraction, immunoaffinity column (IAC) clean-up and on-line post-column photochemical derivatization (PCD). Aflatoxins B 1 , B 2 , G 1 , G 2 were extracted from samples by using methanol/water (70:30, v/v ) with the addition of NaCl. The solutions were diluted 1:8 with 0.1 M phosphate buffer (pH 8.0) to negate the issues of high acidity and matrix interferences. The established method was validated with satisfactory linearity ( R > 0.999), sensitivity (limits of detection (LODs) and limits of quantitation (LOQs) of 0.15-0.65 and 0.53-2.18 μg/kg, respectively), precision (RSD <11%), stability (RSD of 0.2-3.6%), and accuracy (recovery rates of 86.0-102.3%), which all met the stipulated analytical requirements. Analysis of 28 H. sabdariffa samples indicated that one sample incubated with Aspergillus flavus was positive with aflatoxin B 1 (AFB 1 ) at 3.11 μg/kg. The strategy developed in this study also has the potential to reliably extract and sensitively detect more mycotoxins in other complex acidic matrices, such as traditional Chinese medicines, foodstuffs, etc.
Guo, Hui; Li, Huan; Liu, Xiao; Cai, Hao; Wu, Li; Cai, Bao-Chang
2014-12-01
To develop a high performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometry (ESI-MS) and ultraviolet (UV) detector method for the acid-alkaline simultaneous determination of ten bioactive compounds, and analyze the effect of compatible medicinal plants on the concentration of components in Dahuang Fuzi Tang (DFT). The chromatographic separation was performed on a Hypersil BDS C18 analytical column by gradient elution with acetonitrile and formate buffer (containing 0.15% formic acid, V/V) at 25 °C with a flow rate of 1.0 mL·min(-1) and UV detection at 280 nm. Four of the ten compounds in DFT were identified and their MS fragments were elucidated by HPLC-ESI-MS, and the contents of the six compounds were determined by HPLC-UV. All calibration curves showed good linear regression (r(2) ≥ 0.9990). The limits of detection and limits of quantification were 0.021-0.155 -g·mL(-1) and 0.076-0.520 -g·mL(-1), respectively. Overall precision RSD (intra-day and inter-day) were less than 2.96%, and the average recoveries were 98.35%-101.45%, with RSD ranging from 1.54% to 3.01% for the analytes. The developed method can be applied for the quality control and provide analytical evidence on the chemical basis and combinational principles of DFT. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Kelly, Mary T; Blaise, Alain; Larroque, Michel
2010-11-19
This paper reports a new, simple, rapid and economical method for routine determination of 24 amino acids and biogenic amines in grapes and wine. No sample clean-up is required and total run time including column re-equilibration is less than 40min. Following automated in-loop automated pre-column derivatisation with an o-phthaldialdehyde, N-acetyl-l-cysteine reagent, compounds were separated on a 3mm×25cm C(18) column using a binary mobile phase. The method was validated in the range 0.25-10mg/l; repeatability was less than 3% RSD and the intermediate precision ranged from 2 to 7% RSD. The method was shown to be linear by the 'lack of fit' test and the accuracy was between 97 and 101%. The LLOQ varied between 10μg/l for aspartic and glutamic acids, ethanolamine and GABA, and 100μg/l for tyrosine, phenylalanine, putrescine and cadaverine. The method was applied to grapes, white wine, red wine, honey and three species of physalis fruit. Grapes and physalis fruit were crushed, sieved, centrifuged and diluted 1/20 and 1/100, respectively, for analysis; wines and honeys were simply diluted 10-fold. It was shown using this method that the amino acid content of grapes was strongly correlated with berry volume, moderately correlated with sugar concentration and inversely correlated with total acidity. Copyright © 2010 Elsevier B.V. All rights reserved.
Eberl, Anita; Altendorfer-Kroath, Thomas; Kollmann, Denise; Birngruber, Thomas; Sinner, Frank; Raml, Reingard; Magnes, Christoph
2016-09-15
(2)H2O as nonradioactive, stable marker substance is commonly used in preclinical and clinical studies and the precise determination of (2)H2O concentration in biological samples is crucial. However, aside from isotope ratio mass spectrometry (IRMS), only a very limited number of methods to accurately measure the (2)H2O concentration in biological samples are routinely established until now. In this study, we present a straightforward method to accurately measure (2)H-enrichment of rat brain interstitial fluid (ISF) and rat plasma to determine the relative recovery of a cerebral open flow microperfusion (cOFM) probe, using headspace-gas-chromatography - quadrupole-mass-spectrometry. This method is based on basic-catalyzed hydrogen/deuterium exchange in acetone and detects the (2)H-labelled acetone directly by the headspace GC-MS. Small sample volumes and limited number of preparation steps make this method highly competitive. It has been fully validated. (2)H enriched to 8800 ppm in plasma showed an accuracy of 98.9% and %Relative Standard Deviation (RSD) of 3.1 with n = 18 over three days and with two operators. Similar performance was obtained for cerebral ISF enriched to 1100 ppm (accuracy: 96.5%, %RSD: 3.1). With this highly reproducible method we demonstrated the successful employment of (2)H2O as performance marker for a cOFM probe. Copyright © 2016. Published by Elsevier Inc.
Gabbanini, Simone; Matera, Riccardo; Valvassori, Alice; Valgimigli, Luca
2015-04-15
A novel method for the UHPLC-MS/MS analysis of (E)-4-hydroxynonenal (4-HNE) is described. The method is based on derivatization of 4-HNE with pentafluorophenylhydrazine (1) or 4-trifluoromethylphenylhydrazine (2) in acetonitrile in the presence of trifluoroacetic acid as catalyst at room temperature and allows complete analysis of one sample of vegetable oil in only 21 min, including sample preparation and chromatography. The method involving hydrazine 1, implemented in an ion trap instrument with analysis of the transition m/z 337→154 showed LOD=10.9 nM, average accuracy of 101% and precision ranging 2.5-4.0% RSD intra-day (2.7-4.1% RSD inter-day), with 4-HNE standard solutions. Average recovery from lipid matrices was 96.3% from vaseline oil, 91.3% from sweet almond oil and 105.3% from olive oil. The method was tested on the assessment of safety and oxidative degradation of seven samples of dietary oil (soybean, mixed seeds, corn, peanut, sunflower, olive) and six cosmetic-grade oils (avocado, blackcurrant, apricot kernel, echium, sesame, wheat germ) and effectively detected increased 4-HNE levels in response to chemical (Fenton reaction), photochemical, or thermal stress and aging, aimed at mimicking typical oxidation associated with storage or industrial processing. The method is a convenient, cost-effective and reliable tool to assess quality and safety of vegetable oils. Copyright © 2015 Elsevier B.V. All rights reserved.
Rafi, Mohamad; Lim, Lee Wah; Takeuchi, Toyohide; Darusman, Latifah Kosim
2013-01-15
A new method using reversed phase capillary liquid chromatography was developed for simultaneous determination of four bioactive compounds found in ginger (Zingiber officinale) namely, 6-, 8-, 10-gingerol, and 6-shogaol. The separation of these four compounds was performed using C30 as the stationary phase and 60% acetonitrile as the mobile phase in isocratic elution mode with a flow rate of 5 μL/min. All four compounds were separated within 25 min with good resolution. As the evaluation of method validation, a linear regression of the four compounds was obtained within the tested range with correlation coefficients ≥ 0.9995. The limits of detection and quantitation were between 0.034-0.039 μg/mL and 0.112-0.129 μg/mL, respectively. Intra- and inter-day precision expressed as relative standard deviations (RSD) were less than 3.1%, and the accuracy based on recovery test was ranging from 97% to 105%. Stability of the analytes within 1 day was found in the range between 1.34% and 2.93% (RSD). In addition, based on the amount of these four compounds combining with the discriminant analysis, a reliable and accurate method was developed for discrimination of three ginger varieties found in Indonesia. The results indicated that the developed method could be used as quality control for ginger raw material and its related products. Copyright © 2012 Elsevier B.V. All rights reserved.
Kumar, Sunil; Singh, Awantika; Kumar, Brijesh; Singh, Bikarma; Bahadur, Lal; Lal, Mohan
2018-03-20
A rapid, sensitive and reproducible method using ultra-high-performance liquid chromatography coupled with electrospray ionization hybrid triple quadrupole-linear ion trap mass spectrometry (UHPLC-ESI-QqQ LIT -MS/MS) in multiple reaction monitoring (MRM) mode was developed and validated for simultaneous quantitation of anticancer (vincristine, vinblastine, vindesine), antihypertensive (ajmaline, ajmalicine, reserpine), aphrodisiac (yohimbine), sedative (serpentine) agents, dietary supplement (vinpocetine, yohimbine) and precursor of vinblastine (vindoline) from crude extracts of Catharanthus roseus. The precursor to product ion transitions for these compounds were observed at m/z 327 → 144, 355 → 144, 754 → 355, 353 → 144, 349 → 317, 825 → 225, 811 → 224, 458 → 188, 351 → 280 and 609 → 195, respectively in positive ionization mode. Chromatographic separation of all targeted TIAs was performed on ACQUITY UPLC BEH™ C 18 column (1.7 μm, 2.1 mm × 50 mm). The calibration curves were linear within the concentration range 0.5-1000 ng/mL and correlation coefficients (R 2 ) were closer to 1. Limit of detection (LOD) and limit of quantitation (LOQ) ranged from 0.039-0.583 ng/mL and 0.118-1.767 ng/mL, respectively. The intra-day (0.23-2.71% RSD) and inter-day (0.40-2.90% RSD) precision, stability (0.69-3.45% RSD) and recovery (99.63-104.30% ± %RSD ≤ 3.03%) were acceptable indicating good accuracy of the developed method. The method was successfully applied in ethanolic extracts of 39 samples of C. roseus parts (leaf, stem and root) collected from five different locations in India. Serpentine was detected as one of the most abundant TIA. Principal component analysis (PCA) was able to successfully discriminate among C. roseus samples on the basis of content of targeted TIAs. Copyright © 2017 Elsevier B.V. All rights reserved.
Cordeiro, Fernando; Robouch, Piotr; de la Calle, Maria Beatriz; Emteborg, Håkan; Charoud-Got, Jean; Schmitz, Franz
2011-01-01
A collaborative study, International Evaluation Measurement Programme-25a, was conducted in accordance with international protocols to determine the performance characteristics of an analytical method for the determination of dissolved bromate in drinking water. The method should fulfill the analytical requirements of Council Directive 98/83/EC (referred to in this work as the Drinking Water Directive; DWD). The new draft standard method under investigation is based on ion chromatography followed by post-column reaction and UV detection. The collaborating laboratories used the Draft International Organization for Standardization (ISO)/Draft International Standard (DIS) 11206 document. The existing standard method (ISO 15061:2001) is based on ion chromatography using suppressed conductivity detection, in which a preconcentration step may be required for the determination of bromate concentrations as low as 3 to 5 microg/L. The new method includes a dilution step that reduces the matrix effects, thus allowing the determination of bromate concentrations down to 0.5 microg/L. Furthermore, the method aims to minimize any potential interference of chlorite ions. The collaborative study investigated different types of drinking water, such as soft, hard, and mineral water. Other types of water, such as raw water (untreated), swimming pool water, a blank (named river water), and a bromate standard solution, were included as test samples. All test matrixes except the swimming pool water were spiked with high-purity potassium bromate to obtain bromate concentrations ranging from 1.67 to 10.0 microg/L. Swimming pool water was not spiked, as this water was incurred with bromate. Test samples were dispatched to 17 laboratories from nine different countries. Sixteen participants reported results. The repeatability RSD (RSD(r)) ranged from 1.2 to 4.1%, while the reproducibility RSD (RSDR) ranged from 2.3 to 5.9%. These precision characteristics compare favorably with those of ISO 15601. A thorough comparison of the performance characteristics is presented in this report. All method performance characteristics obtained in the frame of this collaborative study indicate that the draft ISO/DIS 11206 standard method meets the requirements set down by the DWD. It can, therefore, be considered to fit its intended analytical purpose.
Renal denervation for the management of resistant hypertension
Patel, Hitesh C; Hayward, Carl; Vassiliou, Vassilis; Patel, Ketna; Howard, James P; Di Mario, Carlo
2015-01-01
Renal sympathetic denervation (RSD) as a therapy for patients with resistant hypertension has attracted great interest. The majority of studies in this field have demonstrated impressive reductions in blood pressure (BP). However, these trials were not randomized or sham-controlled and hence, the findings may have been overinflated due to trial biases. SYMPLICITY HTN-3 was the first randomized controlled trial to use a blinded sham-control and ambulatory BP monitoring. A surprise to many was that this study was neutral. Possible reasons for this neutrality include the fact that RSD may not be effective at lowering BP in man, RSD was not performed adequately due to limited operator experience, patients’ adherence with their anti-hypertensive drugs may have changed during the trial period, and perhaps the intervention only works in certain subgroups that are yet to be identified. Future studies seeking to demonstrate efficacy of RSD should be designed as randomized blinded sham-controlled trials. The efficacy of RSD is in doubt, but many feel that its safety has been established through the thousands of patients in whom the procedure has been performed. Over 90% of these data, however, are for the Symplicity™ system and rarely extend beyond 12 months of follow-up. Long-term safety cannot be assumed with RSD and nor should it be assumed that if one catheter system is safe then all are. We hope that in the near future, with the benefit of well-designed clinical trials, the role of renal denervation in the management of hypertension will be established. PMID:26672761
Lurz, Philipp; Okon, Thomas; Riede, Thomas; Wagner, Robert; Schuler, Gerhard; Daehnert, Ingo; Desch, Steffen
2016-01-01
Uncontrolled arterial hypertension is a frequent problem after successful repair of CoA and has been attributed to increased central sympathetic drive as well as a blunted baroreceptor reflex. RSD is a promising therapy to reduce central sympathetic drive and improve baroreflex sensitivity. 8 patients (age: 27±6 years) with previous surgical and/or percutaneous repair of CoA, absence of any relevant restenosis (invasive gradient across the site of previous treatment 3±4 mmHg) and resistant arterial hypertension (daytime SBP≥140 mmHg on 24 hour ambulatory blood pressure measurements [ABPM] in spite of the concurrent use of 3 antihypertensive agents of different classes or intolerance to BP medications) were included. Bilateral RSD was performed using the Symplicity Flex™ catheter (Medtronic, MN, USA). RSD was successful in all patients with no procedural complications and no evidence for renal artery stenosis 6 months post procedure. From baseline to 6 month follow-up, RSD was followed by a significant reduction in average daytime systolic BP (150.4±7.8 to 143.1±8.0 mmHg; p=0.0117) as well as systolic BP throughout 24 h (146.8±7.3 vs. 140.5±7.8, p=0.04). The BP reductions observed in these patients justify engaging in a larger clinical trial on the efficacy of RSD in this specific type of secondary hypertension and bares the hope that RSD might extend the currently very limited armory against arterial hypertension in young adults with previous repair of CoA. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Xu, Zhang-Run; Zhong, Chong-Hui; Guan, Yan-Xia; Chen, Xu-Wei; Wang, Jian-Hua; Fang, Zhao-Lun
2008-10-01
A miniaturized flow injection analysis (FIA) system integrating a micropump on a microfluidic chip based on capillary and evaporation effects was developed. The pump was made by fixing a filter paper plug with a vent tube at the channel end, it requires no peripheral equipment and provides steady flow in the microl min(-1) range for FIA operation. Valve-free sample injection was achieved at nanolitre level using an array of slotted vials. The practical applicability of the system was demonstrated by DNA assay with laser-induced fluorescence (LIF) detection. A precision of 1.6% RSD (10.0 ng microl(-1), n=15) was achieved with a sampling throughput of 76 h(-1) and sample consumption of 95 nl.
Ramirez, Karol; Niraula, Anzela; Sheridan, John F
2016-01-01
Psychosocial stress is associated with altered immunity, anxiety, and depression. Repeated social defeat (RSD), a model of social stress, triggers egress of inflammatory myeloid progenitor cells (MPCs; CD11b(+)/Ly6C(hi)) that traffic to the brain, promoting anxiety-like behavior. In parallel, RSD enhances neuroinflammatory signaling and long-lasting social avoidant behavior. Lorazepam and clonazepam are routinely prescribed anxiolytics that act by enhancing GABAergic activity in the brain. Besides binding to the central benzodiazepine binding site (CBBS) in the central nervous system (CNS), lorazepam binds to the translocator protein (TSPO) with high affinity causing immunomodulation. Clonazepam targets the CBBS and has low affinity for the TSPO. Here the aims were to determine if lorazepam and clonazepam would: (1) prevent stress-induced peripheral and central inflammatory responses, and (2) block anxiety and social avoidance behavior in mice subjected to RSD. C57/BL6 mice were divided into experimental groups, and treated with either lorazepam (0.10mg/kg), clonazepam (0.25mg/kg) or vehicle (0.9% NaCl). Behavioral data and tissues were collected the morning after the last cycle of RSD. Lorazepam and clonazepam were effective in attenuating mRNA expression of CRH in the hypothalamus and corticosterone in plasma in mice subjected to RSD. Both drugs blocked stress-induced levels of IL-6 in plasma. Lorazepam and clonazepam had different effects on stress-induced enhancement of myelopoiesis and inhibited trafficking of monocytes and granulocytes in circulation. Furthermore, lorazepam, but not clonazepam, inhibited splenomegaly and the production of pro-inflammatory cytokines in the spleen following RSD. Additionally, lorazepam and clonazepam, blocked stress-induced accumulation of macrophages (CD11b(+)/CD45(high)) in the CNS. In a similar manner, both lorazepam and clonazepam prevented neuroinflammatory signaling and reversed anxiety-like and depressive-like behavior in mice exposed to RSD. These data support the notion that lorazepam and clonazepam, aside from exerting anxiolytic and antidepressant effects, may have therapeutic potential as neuroimmunomodulators during psychosocial stress. The reversal of RSD-induced behavioral outcomes may be due to the enhancement of GABAergic neurotransmission, or some other off-target effect. The peripheral actions of lorazepam, but not clonazepam, seem to be mediated by TSPO activation. Copyright © 2015 Elsevier Inc. All rights reserved.
Ramirez, Karol; Niraula, Anzela; Sheridan, John F.
2015-01-01
Objective Psychosocial stress is associated with altered immunity, anxiety, and depression. Repeated social defeat (RSD), a model of social stress, triggers egress of inflammatory myeloid progenitor cells (MPCs; CD11b+ /Ly6Chi) that traffic to the brain, promoting anxiety-like behavior. In parallel, RSD enhances neuroinflammatory signaling and long-lasting social avoidant behavior. Lorazepam and clonazepam are routinely prescribed anxiolytics that act by enhancing GABAergic activity in the brain. Besides binding to the central benzodiazepine binding site (CBBS) in the central nervous system (CNS), lorazepam binds to the translocator protein (TSPO) with high affinity causing immunomodulation. Clonazepam targets the CBBS and has low affinity for the TSPO. Here the aims were to determine if lorazepam and clonazepam would: 1) prevent stress-induced peripheral and central inflammatory responses, and 2) block anxiety and social avoidance behavior in mice subjected to RSD. Methods C57/BL6 mice were divided into experimental groups, and treated with either lorazepam (0.10mg/kg), clonazepam (0.25 mg/kg) or vehicle (0.9%NaCl). Behavioral data and tissues were collected the morning after the last cycle of RSD. Results Lorazepam and clonazepam were effective in attenuating mRNA expression of CRH in the hypothalamus and corticosterone in plasma in mice subjected to RSD. Both drugs blocked stress-induced levels of IL-6 in plasma. Lorazepam and clonazepam had different effects on stress-induced enhancement of myelopoiesis and inhibited trafficking of monocytes and granulocytes in circulation. Furthermore, lorazepam, but not clonazepam, inhibited splenomegaly and the production of pro-inflammatory cytokines in the spleen following RSD. Additionally, lorazepam and clonazepam, blocked stress-induced accumulation of macrophages (CD11b+/CD45high) in the CNS. In a similar manner, both lorazepam and clonazepam prevented neuroinflammatory signaling and reversed anxiety-like and depressive-like behavior in mice exposed to RSD. Conclusion These data support the notion that lorazepam and clonazepam, aside from exerting anxiolytic and antidepressant effects, may have therapeutic potential as neuroimmunomodulators during psychosocial stress. The reversal of RSD-induced behavioral outcomes may be due to the enhancement of GABAergic neurotransmission, or some other off-target effect. The peripheral actions of lorazepam, but not clonazepam, seem to be mediated by TSPO activation. PMID:26342944
Neuroinflammatory Dynamics Underlie Memory Impairments after Repeated Social Defeat.
McKim, Daniel B; Niraula, Anzela; Tarr, Andrew J; Wohleb, Eric S; Sheridan, John F; Godbout, Jonathan P
2016-03-02
Repeated social defeat (RSD) is a murine stressor that recapitulates key physiological, immunological, and behavioral alterations observed in humans exposed to chronic psychosocial stress. Psychosocial stress promotes prolonged behavioral adaptations that are associated with neuroinflammatory signaling and impaired neuroplasticity. Here, we show that RSD promoted hippocampal neuroinflammatory activation that was characterized by proinflammatory gene expression and by microglia activation and monocyte trafficking that was particularly pronounced within the caudal extent of the hippocampus. Because the hippocampus is a key area involved in neuroplasticity, behavior, and cognition, we hypothesize that stress-induced neuroinflammation impairs hippocampal neurogenesis and promotes cognitive and affective behavioral deficits. We show here that RSD caused transient impairments in spatial memory recall that resolved within 28 d. In assessment of neurogenesis, the number of proliferating neural progenitor cells (NPCs) and the number of young, developing neurons were not affected initially after RSD. Nonetheless, the neuronal differentiation of NPCs that proliferated during RSD was significantly impaired when examined 10 and 28 d later. In addition, social avoidance, a measure of depressive-like behavior associated with caudal hippocampal circuitry, persisted 28 d after RSD. Treatment with minocycline during RSD prevented both microglia activation and monocyte recruitment. Inhibition of this neuroinflammatory activation in turn prevented impairments in spatial memory after RSD but did not prevent deficits in neurogenesis nor did it prevent the persistence of social avoidance behavior. These findings show that neuroinflammatory activation after psychosocial stress impairs spatial memory performance independent of deficits in neurogenesis and social avoidance. Repeated exposure to stress alters the homeostatic environment of the brain, giving rise to various cognitive and mood disorders that impair everyday functioning and overall quality of life. The brain, previously thought of as an immune-privileged organ, is now known to communicate extensively with the peripheral immune system. This brain-body communication plays a significant role in various stress-induced inflammatory conditions, also characterized by psychological impairments. Findings from this study implicate neuroimmune activation rather than impaired neurogenesis in stress-induced cognitive deficits. This idea opens up possibilities for novel immune interventions in the treatment of cognitive and mood disturbances, while also adding to the complexity surrounding the functional implications of adult neurogenesis. Copyright © 2016 the authors 0270-6474/16/362590-15$15.00/0.
Quantification of almond skin polyphenols by liquid chromatography-mass spectrometry.
Bolling, Bradley W; Dolnikowski, Gregory; Blumberg, Jeffrey B; Oliver Chen, C Y
2009-01-01
Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic acids from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-day relative standard deviation (RSD) of standard curve slopes ranged from 13% to 25% of the mean. On column (OC) limits of detection (LOD) for polyphenols ranged from 0.013 to 1.4 pmol, and flavonoid glycosides had a 7-fold greater sensitivity than aglycones. Limits of quantification were 0.043 to 2.7 pmol OC, with a mean of 0.58 pmol flavonoid OC. Mean inter-day RSD of polyphenols in almond skin extract was 6.8% with a range of 4% to 11%, and intra-day RSD was 2.4%. Liquid nitrogen (LN(2)) or hot water (HW) blanching was used to facilitate removal of the almond skins prior to extraction using assisted solvent extraction (ASE) or steeping with acidified aqueous methanol. Recovery of polyphenols was greatest in HW blanched almond extracts with a mean value of 2.1 mg/g skin. ASE and steeping extracted equivalent polyphenols, although ASE of LN(2) blanched skins yielded 52% more aglycones and 23% less flavonoid glycosides. However, the extraction methods did not alter flavonoid profile of HW blanched almond skins. The recovery of polyphenolic components that were spiked into almond skins before the steeping extraction was 97% on a mass basis. This LC-MS method presents a reliable means of quantifying almond polyphenols.
Quantification of Almond Skin Polyphenols by Liquid Chromatography-Mass Spectrometry
Bolling, Bradley W.; Dolnikowski, Gregory; Blumberg, Jeffrey B.; Oliver Chen, C.Y.
2014-01-01
Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic acids from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-day relative standard deviation (RSD) of standard curve slopes ranged from 13% to 25% of the mean. On column (OC) limits of detection (LOD) for polyphenols ranged from 0.013 to 1.4 pmol, and flavonoid glycosides had a 7-fold greater sensitivity than aglycones. Limits of quantification were 0.043 to 2.7 pmol OC, with a mean of 0.58 pmol flavonoid OC. Mean inter-day RSD of polyphenols in almond skin extract was 6.8% with a range of 4% to 11%, and intra-day RSD was 2.4%. Liquid nitrogen (LN2) or hot water (HW) blanching was used to facilitate removal of the almond skins prior to extraction using assisted solvent extraction (ASE) or steeping with acidified aqueous methanol. Recovery of polyphenols was greatest in HW blanched almond extracts with a mean value of 2.1 mg/g skin. ASE and steeping extracted equivalent polyphenols, although ASE of LN2 blanched skins yielded 52% more aglycones and 23% less flavonoid glycosides. However, the extraction methods did not alter flavonoid profile of HW blanched almond skins. The recovery of polyphenolic components that were spiked into almond skins before the steeping extraction was 97% on a mass basis. This LC-MS method presents a reliable means of quantifying almond polyphenols. PMID:19490319
Marković, Veroljub; Kostić, Marina; Iličković, Ivana; Janković, Slobodan M
2014-09-01
Recent studies have shown that fidaxomicin, a novel antibiotic, can reduce the rate of complications and mortality in patients with colitis induced by Clostridium difficile. Introduction of fidaxomicin in clinical practice is limited by its high costs. The purpose of this study was to estimate the cost effectiveness of using fidaxomicin versus vancomycin in patients with colitis induced by C. difficile who did not respond to oral metronidazole. We constructed a Markov model that was than simulated by Monte-Carlo simulation using 1000 virtual patients with colitis induced by C. difficile. The perspective in our model was institutional. The time horizon was 3 months. Values of transition probabilities and therapy outcomes were estimated from the available literature, the prices of health services were obtained from the Republic Institute for Health Insurance Tariff Book, and the price of fidaxomicin was derived from data gained from the drug manufacturer. The total costs of treating one statistical patient for 3 months with fidaxomicin were higher (48,106.19 ± 118.07 Republic of Serbia dinars [RSD]; 95% confidence interval 47,988.12-48,224.27) than the total costs of treating with vancomycin (25,872.85 ± 41.44 RSD; 95% confidence interval 25,831.41-25,914.29). Our results showed that the treatment of infections induced by C. difficile with fidaxomicin correlated with a lower rate of mortality and with a smaller number of colectomies. The incremental cost-effectiveness ratio of fidaxomicin versus vancomycin for colitis induced by C. difficile per saved life was estimated at 2.97 million RSD and for one avoided colectomy at 10.07 million RSD. Results of our model indicate that fidaxomicin is a cost-effective therapy compared with vancomycin in patients with colitis induced by C. difficile if the outcome is life-year saved. However, if the outcome is the number of avoided colectomies, then fidaxomycin is not a cost-effective option compared with vancomycin. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Commercial vehicle (CV) retrofit safety device (RSD) kits project.
DOT National Transportation Integrated Search
2014-07-01
Retrofit Safety Device (RSD) kits were developed and deployed on commercial vehicles as part of the U.S. DOT Connected Vehicle Safety Pilot to gain insight into the unique aspects of deploying connected vehicle technology in a commercial vehicle envi...
2014-08-01
2013 for largemouth bass only. Year Largemouth bass CPUE1 (Total no/hr) PSD2 RSD -P3 1994 61 80 43 1995 61 49 9 1996 84 57 17 1997 59 95 15 1998...of 50-80 for bass is desirable for a pond manager with trophy bass goals. 3 RSD (relative stock density) - The relative stock density is the...percentage of fish of any designated length-group in a sample of fish. Within that sample the RSD -P is the percentage of those fish that are of preferred
Geertzen, J H; Dijkstra, P U; van Sonderen, E L; Groothoff, J W; ten Duis, H J; Eisma, W H
1998-10-01
To determine the relationship between impairments, disability and handicap in reflex sympathetic dystrophy (RSD) patients. A long-term follow-up study of upper extremity RSD patients. A university hospital. Sixty-five patients, 3-9 years (mean interval 5.5 years) after RSD of the upper extremity (mean age 50.2 years). Impairments: range of motion, moving two point discrimination, muscle strength of the hand and pain were measured. Disability was assessed with the Groningen Activity Restriction Scale (GARS) and handicap was assessed with three subscales (social functioning, role limitations due to physical problems and role limitations due to emotional problems) of the RAND-36. After RSD of the upper extremity, 62% of the patients are limited in activities of daily living (ADL) and/or instrumental ADL (IADL). Pain and restrictions in forward flexion of the shoulder, thumb opposition and grip strength are the most important impairments limiting ADL and IADL. Patients with limitations in ADL and IADL are significantly more handicapped than patients without limitations. Pain is the most important factor contributing to handicap. The relationship between impairments and disability and between disability and handicap in RSD patients is weak to moderate. Pain is the most important factor leading to disability and handicap.