Intentions to Maintain Adherence to Mammography
Bowling, J. Michael; Brewer, Noel T.; Lipkus, Isaac M.; Skinner, Celette Sugg; Strigo, Tara S.; Rimer, Barbara K.
2008-01-01
Abstract Objective Recent attention has focused on moving women from having initial mammograms to maintaining adherence to regular mammography schedules. We examined behavioral intentions to maintain mammography adherence, which include the likelihood of performing a behavior, and implementation intentions, specific action plans to obtain mammograms. Potential predictors were Theory of Planned Behavior constructs, previous barriers, previous mammography maintenance, and age. Methods Respondents were 2062 currently adherent women due for their next mammograms in 3–4 months according to American Cancer Society recommendations for annual screening. Statistical models were used to examine predictors of behavioral and two implementation intentions, including having thought about where women would get their next mammograms and having thought about making appointments. Results With the exception of pros, cons, and subjective norms, all variables predicted behavioral intentions (p ≤ 0.05). Stronger perceived control, previous mammography maintenance, and one barrier (vs. none) predicted being more likely to have thought about where to get their next mammograms. Previous maintenance and no barriers (vs. two) predicted being more likely to have thought about making appointments. Conclusions Our findings suggest that among women currently adherent to mammography, volitional factors, such as barriers, may be better predictors of implementation intentions than motivational factors, such as attitudes. Implementation variables may be useful in understanding how women move from intentions to action. Future research should examine how such factors relate to mammography maintenance behaviors and can be integrated into behavior change interventions. PMID:18657041
Murphy, Caitlin C.; Vernon, Sally W.; Diamond, Pamela M.; Tiro, Jasmin A.
2013-01-01
Background Competitive hypothesis testing may explain differences in predictive power across multiple health behavior theories. Purpose We tested competing hypotheses of the Health Belief Model (HBM) and Theory of Reasoned Action (TRA) to quantify pathways linking subjective norm, benefits, barriers, intention, and mammography behavior. Methods We analyzed longitudinal surveys of women veterans randomized to the control group of a mammography intervention trial (n=704). We compared direct, partial mediation, and full mediation models with Satorra-Bentler χ2 difference testing. Results Barriers had a direct and indirect negative effect on mammography behavior; intention only partially mediated barriers. Benefits had little to no effect on behavior and intention; however, it was negatively correlated with barriers. Subjective norm directly affected behavior and indirectly affected intention through barriers. Conclusions Our results provide empiric support for different assertions of HBM and TRA. Future interventions should test whether building subjective norm and reducing negative attitudes increases regular mammography. PMID:23868613
Siegel, P Z; Qualters, J R; Mowery, P D; Campostrini, S; Leutzinger, C; McQueen, D V
2001-01-01
OBJECTIVES: This study investigated whether an apparent downturn in prevalence rates of mammography use reported in the 1992 Behavioral Risk Factor Surveillance System (BRFSS) questionnaire resulted from a change in questionnaire wording. METHODS: In a pretest-posttest design (1990-1991 vs 1992), piecewise linear regression analyses were based on monthly prevalence estimates of mammography use among female BRFSS respondents 40 years or older. RESULTS: Self-reported mammography use was lower by 3.5 percentage points (95% confidence interval [CI] = 1.5, 5.5) overall--and lower by 13.6 percentage points (95% CI = 2.6, 24.6) among Black women with less than a high school education--when predicted from 1992 data than when predicted from 1990-1991 data. CONCLUSIONS: A change in questionnaire wording in the BRFSS caused demographic-specific effects in population-based estimates of mammography use. PMID:11344896
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voisin, Sophie; Pinto, Frank M; Morin-Ducote, Garnetta
2013-01-01
Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels. Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from 4 Radiology residents and 2 breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADsmore » images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated. Results: Diagnostic error can be predicted reliably by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model (AUC=0.79). Personalized user modeling was far more accurate for the more experienced readers (average AUC of 0.837 0.029) than for the less experienced ones (average AUC of 0.667 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features. Conclusions: Diagnostic errors in mammography can be predicted reliably by leveraging the radiologists gaze behavior and image content.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voisin, Sophie; Tourassi, Georgia D.; Pinto, Frank
2013-10-15
Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS imagesmore » features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.« less
Fair, Alecia Malin; Monahan, Patrick O.; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L.
2013-01-01
PURPOSE/OBJECTIVES To test the interaction of perceived risk and benefits on stage of mammography readiness and adherence. DESIGN Cross-sectional study SETTING Community gathering places and health care clinics across a Midwestern state. SAMPLE 299 African-American women who had not had a mammogram in ≥ 18 months. METHODS In-person interviews were used to collect data on sociodemographics, health belief variables and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high/low levels of perceived risk and benefit with health belief variables linked to modifying mammography screening behavior. MAIN RESEARCH VARIABLES Perceived risks and benefits, stage of readiness, mammography adherence. FINDINGS The lowest rate of mammography adherence was in women with a high perceived risk and low benefit towards mammography adherence (25.6) compared to women with a high perceived benefit and low risk towards mammography adherence (46.0). Differences in mammography adherence were statistically significant between these groups p=(0.009). CONCLUSIONS The interaction of high perceived risk and low benefits additively effected readiness to undertake screening mammography. IMPLICATIONS FOR NURSING Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. Minority, medically underserved women with perceived high risk and low benefits exhibit immobilization to move forward with mammography adherence when they experience higher perceived risk. Further interventions to increase the perception of benefit of mammography are recommended to reduce breast cancer mortality. PMID:22201655
Fair, Alecia Malin; Monahan, Patrick O; Russell, Kathleen; Zhao, Qianqian; Champion, Victoria L
2012-01-01
To test the interaction of perceived risk and benefits and how they impact stage of mammography readiness and adherence. Cross-sectional study. Community gathering centers and healthcare clinics across Indiana. 299 African American women who had not had a mammogram in more than 18 months. In-person interviews were used to collect data on sociodemographics, health belief variables, and stage of readiness to undertake mammography screening. Four categories were created to measure the combined magnitude of high or low levels of perceived risk and benefit, with health belief variables linked to modified mammography screening behavior. Perceived risks and benefits, stage of readiness, and mammography adherence. The lowest rate of mammography adherence was in women with a high perceived risk and low perceived benefit toward mammography adherence (26%). The highest rate of adherence was in women with a high perceived benefit and low perceived risk (46%). Differences in mammography adherence were statistically significant between the groups (p = 0.009). The interaction of high perceived risk and low perceived benefits impacted readiness to undergo screening mammography. Reducing disparities in breast cancer diagnosis and survival requires timely and efficient mammography adherence. African American medically underserved women with high perceived risk and low perceived benefits exhibited a reluctance to move forward with mammography adherence. Interventions are needed to increase the perception of mammography benefit and to subsequently reduce breast cancer mortality rates in that population.
Correlates of mammography utilization among working Muslim Iranian women.
Hatefnia, Effat; Niknami, Shamsaddin; Bazargan, Mohsen; Mahmoodi, Mahmood; Lamyianm, Minoor; Alavi, Nasrien
2010-06-01
Most countries in Middle East have been successful in establishing and furthering basic facilities for screening, diagnosis, and treatment of breast cancer. The rate of compliance with mammography screening, however, remains well below North American and Western European countries. We utilized the Health Belief Model (HBM) to explore factors associated with mammography screening behavior among a sample of 320 Muslim women aged > or = 35. Carrying out this cross-sectional study, we found that screening behavior was associated with older age, higher perceived benefit of breast cancer screening, and lower perceived barrier. Additionally, we demonstrate the importance of religious beliefs in influencing mammography screening behavior and explaining the link between religious involvement and mammography behavior.
Weeks, Brian E; Friedenberg, Laura M; Southwell, Brian G; Slater, Jonathan S
2012-01-01
Building on channel complementarity theory and media-system dependency theory, this study explores the impact of conflict-oriented news coverage of health issues on information seeking online. Using Google search data as a measure of behavior, we demonstrate that controversial news coverage of the U.S. Preventive Services Task Force's November 2009 recommendations for changes in breast cancer screening guidelines strongly predicted the volume of same-day online searches for information about mammograms. We also found that this relationship did not exist 1 year prior to the coverage, during which mammography news coverage did not focus on the guideline controversy, suggesting that the controversy frame may have driven search behavior. We discuss the implications of these results for health communication scholars and practitioners.
Socio-Cognitive Determinants of the Mammography Screening Uptake among Iranian Women
Mirzaei-Alavijeh, Mehdi; Ghorbani, Parvaneh; Jalilian, Farzad
2018-05-26
Background: Mammography screening uptake is the most effective method in breast cancer screening. The aim of this study was to determine the determinants related to mammography screening uptake among Iranian women based on the theory of planned behavior. Materials and Methods: This cross-sectional study was conducted among 408 women who referred to health centers in Kermanshah city, the western of Iran, during 2016. Participants filled out a self-administered questionnaire. Data were analyzed by SPSS version 21 using Pearson correlation, linear and logistic regression statistical tests at 95% significant level. Results: The mean age of participants was 39.61 years [SD: 8.28], ranged from 30 to 60 years. Almost 13% of the participants had already mammography screening uptake at least once. Perceived behavioral control (OR=1.229) and behavioral intention (OR=1.283) were the more influential predictors on mammography screening uptake. Conclusions: Based on result, it seems increase perceived behavior control toward mammography screening uptake may be usefulness in promotion of mammography screening uptake among Iranian women. Creative Commons Attribution License
Farzaneh, Esmaeil; Heydari, Heshmatolah; Shekarchi, Ali Akbar; Kamran, Aziz
2017-01-01
Breast and cervical cancers are the most commonly diagnosed type of cancer and cause of cancer-related deaths in Iranian females. In contrast to previous studies, this study was carried out with a large sample size for assessment of breast self-examination (BSE)-, clinical breast examination (CBE)-, mammography-, and Pap smear-uptake rates and determination of associations among these screening behaviors with sociodemographic and cognitive variables in Azeri females. This was a cross-sectional, community-based study that was carried out among 1,134 females 20-60 years old during March-June 2016. Data-collection variables included sociodemographic questions, screening behaviors for breast and cervical cancer, self-efficacy, beliefs, and barriers to breast and cervical cancer screening. Collected data were analyzed by SPSS version 13 using χ 2 , Mann-Whitney U , and logistic regression tests. Among the 1,134 participants, 53.9%, 9.8%, and 28.1% had done BSE, CBE, and Pap smear tests, respectively, and among the 625 females aged >40 years, 187 (29.9%) had done the mammography test. Moreover, 416 (36.7%), 103 (16.5%), and 64 (5.6%) females had done BSE, mammography, and CBE regularly, respectively. Beliefs, barriers, income, health insurance, number of children, and age were all important factors for BSE and regular BSE and mammography. Females who had high belief scores were more likely to undertake mammography (odds ratio [OR]: 1.2, 95% confidence interval [CI]: 1.03-1.5), regular mammography (OR: 4.2, 95% CI: 1.9-9.3), regular CBE (OR: 1.25, 95% CI: 1.2-1.3), and Pap smears (OR: 1.2, 95% CI: 1.1-1.4). Also, females who had high self-efficacy scores were more likely to perform regular BSE (OR: 1.8, 95% CI: 1.4-2.5) and mammography (OR: 2.5, 95% CI: 1.4-4.6) than females with lower self-efficacy scores. The frequency of breast and cervical cancer screening was low in our study. The findings of this study indicated that beliefs, self-efficacy, and barriers were important predictive factors of cancer-screening behavior among the females studied.
Miller, Sarah J; O'Hea, Erin L; Lerner, Jennifer Block; Moon, Simon; Foran-Tuller, Kelly A
2011-10-01
Although mammography can aid in the early detection and prevention of breast cancer, many women do not receive annual mammograms. It remains unclear whether anxiety about breast cancer inhibits or promotes mammography rates. The way in which women regulate their anxiety (ie, level of experiential avoidance) may play a role in predicting mammography adherence. A community sample of women (N = 84) completed a questionnaire which assessed mammography rates, experiential avoidance, and breast cancer anxiety. The results suggest that, while controlling for breast cancer anxiety, experiential avoidance (β = .31, p < .01) significantly predicted mammography rates. When examining experiential avoidance as a moderator, a multiple regression analysis approached significance (R2 Δ = .04, p = .07), suggesting that a woman's level of experiential avoidance influences the relationship between anxiety and mammography. These findings will help enable health care practitioners to better identify women at risk of non-adherence to mammography recommendations.
Borrayo, Evelinn A; Rosales, Monica; Gonzalez, Patricia
2017-06-01
The evidence is limited comparing the effects of entertainment-education (E-E) narrative versus nonnarrative interventions to educate and motivate Latinas to engage in mammography screening. This study compared an E-E narrative intervention to two nonnarrative interventions' effects among Latinas on breast cancer knowledge and motivation, as measured by changes in self-efficacy, behavioral norms, and behavioral intentions to engage in mammography screening. A sample of 141 Spanish-speaking Latinas was randomly assigned to one of three arms: an E-E narrative video, a nonnarrative educational video, and printed educational materials. Using a repeated measures design, the influence of the E-E narrative on pretest to posttest measures was assessed and compared to the influence of the other two interventions. The E-E narrative and nonnarrative interventions significantly increased Latinas' breast cancer knowledge, mammography self-efficacy, and behavioral norms from pretest to posttest. However, the E-E narrative participants' pretest to posttest difference in mammography self-efficacy was significantly higher when compared to the difference of the other two interventions. The effect of the E-E narrative intervention on self-efficacy and behavioral norms was moderated by the participants' absorption in the story and identification with the story characters. E-E narrative and nonnarrative interventions significantly educated and motivated Latinas to engage in mammography screening. The effects on mammography self-efficacy, an important precursor to behavior change, can be more strongly influenced by E-E narratives. Although E-E narrative and nonnarrative interventions were effective, the need still exists to assess if they can ultimately influence lifesaving breast cancer screening behaviors.
Farzaneh, Esmaeil; Heydari, Heshmatolah; Shekarchi, Ali Akbar; Kamran, Aziz
2017-01-01
Purpose Breast and cervical cancers are the most commonly diagnosed type of cancer and cause of cancer-related deaths in Iranian females. In contrast to previous studies, this study was carried out with a large sample size for assessment of breast self-examination (BSE)-, clinical breast examination (CBE)-, mammography-, and Pap smear-uptake rates and determination of associations among these screening behaviors with sociodemographic and cognitive variables in Azeri females. Materials and methods This was a cross-sectional, community-based study that was carried out among 1,134 females 20–60 years old during March–June 2016. Data-collection variables included sociodemographic questions, screening behaviors for breast and cervical cancer, self-efficacy, beliefs, and barriers to breast and cervical cancer screening. Collected data were analyzed by SPSS version 13 using χ2, Mann–Whitney U, and logistic regression tests. Results Among the 1,134 participants, 53.9%, 9.8%, and 28.1% had done BSE, CBE, and Pap smear tests, respectively, and among the 625 females aged >40 years, 187 (29.9%) had done the mammography test. Moreover, 416 (36.7%), 103 (16.5%), and 64 (5.6%) females had done BSE, mammography, and CBE regularly, respectively. Beliefs, barriers, income, health insurance, number of children, and age were all important factors for BSE and regular BSE and mammography. Females who had high belief scores were more likely to undertake mammography (odds ratio [OR]: 1.2, 95% confidence interval [CI]: 1.03–1.5), regular mammography (OR: 4.2, 95% CI: 1.9–9.3), regular CBE (OR: 1.25, 95% CI: 1.2–1.3), and Pap smears (OR: 1.2, 95% CI: 1.1–1.4). Also, females who had high self-efficacy scores were more likely to perform regular BSE (OR: 1.8, 95% CI: 1.4–2.5) and mammography (OR: 2.5, 95% CI: 1.4–4.6) than females with lower self-efficacy scores. Conclusion The frequency of breast and cervical cancer screening was low in our study. The findings of this study indicated that beliefs, self-efficacy, and barriers were important predictive factors of cancer-screening behavior among the females studied. PMID:28255244
van Ravesteyn, Nicolien T; van Lier, Lisanne; Schechter, Clyde B; Ekwueme, Donatus U; Royalty, Janet; Miller, Jacqueline W; Near, Aimee M; Cronin, Kathleen A; Heijnsdijk, Eveline A M; Mandelblatt, Jeanne S; de Koning, Harry J
2015-05-01
The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40-64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]); costs (for screening and diagnostics); and number of women reached. NBCCEDP 2010 data and data representative of the program's target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. The models predicted 8.0-8.3 LYG per 1,000 film screens for black women, 5.9-7.5 for white women, and 4.0-4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%-4%), but had higher costs (34%-35%). Assuming a fixed budget, 25%-26% fewer women could be served, resulting in 22%-24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%-13% increase by only including biennial screening. Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. Copyright © 2015 American Journal of Preventive Medicine. All rights reserved.
Transition From Film to Digital Mammography
van Ravesteyn, Nicolien T.; van Lier, Lisanne; Schechter, Clyde B.; Ekwueme, Donatus U.; Royalty, Janet; Miller, Jacqueline W.; Near, Aimee M.; Cronin, Kathleen A.; Heijnsdijk, Eveline A.M.; Mandelblatt, Jeanne S.; de Koning, Harry J.
2015-01-01
Introduction The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40–64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]), costs (for screening and diagnostics), and number of women reached. Methods NBCCEDP 2010 data and data representative of the program’s target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. Results The models predicted 8.0–8.3 LYG per 1,000 film screens for black women, 5.9–7.5 for white women, and 4.0–4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%–4%), but had higher costs (34%–35%). Assuming a fixed budget, 25%–26% fewer women could be served, resulting in 22%–24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%–13% increase by only including biennial screening. Conclusions Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. PMID:25891052
Understanding women's mammography intentions: a theory-based investigation.
Naito, Mikako; O'Callaghan, Frances V; Morrissey, Shirley
2009-01-01
The present study compared the utility of two models (the Theory of Planned Behavior and Protection Motivation Theory) in identifying factors associated with intentions to undertake screening mammography, before and after an intervention. The comparison was made between the unique components of the two models. The effect of including implementation intentions was also investigated. Two hundred and fifty-one women aged 37 to 69 years completed questionnaires at baseline and following the delivery of a standard (control) or a protection motivation theory-based informational intervention. Hierarchical multiple regressions indicated that theory of planned behavior variables were associated with mammography intentions. Results also showed that inclusion of implementation intention in the model significantly increased the association with mammography intentions. The findings suggest that future interventions aiming to increase screening mammography participation should focus on the theory of planned behavior variables and that implementation intention should also be targeted.
Chagpar, Anees B.; Middleton, Lavinia P.; Sahin, Aysegul A.; Dempsey, Peter; Buzdar, Aman U.; Mirza, Attiqa N.; Ames, Fredrick C.; Babiera, Gildy V.; Feig, Barry W.; Hunt, Kelly K.; Kuerer, Henry M.; Meric-Bernstam, Funda; Ross, Merrick I.; Singletary, S Eva
2006-01-01
Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. PMID:16432360
Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A
2017-08-30
Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well than the one with the observed PMD (0.753). However, in patients with an assigned mammography failure risk >10%, covering about half of all masked tumors, the boosting-based model performed at least as accurately as the original PMD model. Automatically generated texture features can replace semi-automatically determined PMD in a prediction model for mammography failure, such that more than 50% of masked tumors could be discovered.
Padela, Aasim I; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T
2016-10-01
Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors, scant research has examined how religion-related beliefs inform Muslim women's intention for mammography. Our study identifies and examines such beliefs. Muslim women aged 40 years and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the theory of planned behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Fifty women participated in 6 focus groups and 19 in semistructured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past 2 years. Across differences in race/ethnicity and mammography status, women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one's health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant health care. Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one's body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously tailored messages in interventions have the potential to enhance cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.
Padela, Aasim I.; Vu, Milkie; Muhammad, Hadiyah; Marfani, Farha; Mallick, Saleha; Peek, Monica; Quinn, Michael T.
2017-01-01
Objective Studies suggest that American Muslim women underutilize mammography. While religion has a strong influence upon Muslim health behaviors scant research has examined how religion-related beliefs inform Muslim women’s intention for mammography. Our study identifies and examines such beliefs. Methods Muslim women aged 40 and older sampled from mosques participated in focus groups and individual interviews. Drawing upon the Theory of Planned Behavior, interviews elicited salient behavioral, normative, and control beliefs regarding mammography and the influence of Islam upon screening intention. Results Fifty women participated in 6 focus groups and 19 in semi-structured interviews, with near-equal numbers of African American, South Asian, and Arab Muslims. Forty-two percent of participants had not had a mammogram within the past two years. Across differences in race/ethnicity and mammography status women voiced four religion-related salient beliefs that inform mammography intention: (1) the perceived duty to care for one’s health, (2) religious practices as methods of disease prevention, (3) fatalistic notions about health, and (4) comfort with gender concordant healthcare. Conclusions Religious beliefs influence decisions to pursue mammography across the ethnic/racial diversity of Muslim women. Notions about duty to God and the stewardship of one’s body appear to enhance mammography intention. Theocentric notions of cure and illness and varied views regarding personal agency also inform decisional frames that impact mammography intention. Given the salience of religion among our participants, religiously-tailored messages in interventions have the potential to enhance cancer screening. PMID:27424488
Changing patterns of microcalcification on screening mammography for prediction of breast cancer.
Kim, Kwan Il; Lee, Kyung Hee; Kim, Tae Ryung; Chun, Yong Soon; Lee, Tae Hoon; Choi, Hye Young; Park, Heung Kyu
2016-05-01
The presence of microcalcification on mammography is one of the earliest signs in breast cancer detection. However, it is difficult to distinguish malignant calcifications from benign calcifications. The aim of this study is to evaluate correlation between changing patterns of microcalcification on screening mammography and malignant breast lesions. Medical records and diagnostic images of 67 women who had previously undergone at least two digital mammograms at least 6 months apart and underwent mammography-guided needle localization and surgical excision between 2011 and 2013 were retrospectively reviewed and analyzed. Breast cancer was detected in the surgical specimens of 20 patients (29.9 %). Annual change of extent of microcalcification on mammography showed statistically significant correlation with pathologic outcome (P = 0.023). The changing pattern of new appearance or increased extent of microcalcification on mammography had positive predictive value of 54.8 % for breast cancer, and it was a statistically significant predictor for breast cancer (P = 0.012). Shape or number change of microcalcification without increased extent had less accurate predictive value for breast cancer, particularly in women younger than 50 years (P < 0.001). This study showed that the pattern of increased extent of microcalcification on screening mammography was a significant predictor for breast cancer. We suggest that mammography-guided needle localization and surgical excision should be considered when increased extent of microcalcification is observed on screening mammography and closed follow-up without pathologic confirmation can be permitted if absence of extension of microcalcification was confirmed in women younger than 50 years.
Skaane, Per; Young, Kari; Skjennald, Arnulf
2003-12-01
To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.
Development of cultural belief scales for mammography screening.
Russell, Kathleen M; Champion, Victoria L; Perkins, Susan M
2003-01-01
To develop instruments to measure culturally related variables that may influence mammography screening behaviors in African American women. Instrumentation methodology. Community organizations and public housing in the Indianapolis, IN, area. 111 African American women with a mean age of 60.2 years and 64 Caucasian women with a mean age of 60 years. After item development, scales were administered. Data were analyzed by factor analysis, item analysis via internal consistency reliability using Cronbach's alpha, and independent t tests and logistic regression analysis to test theoretical relationships. Personal space preferences, health temporal orientation, and perceived personal control. Space items were factored into interpersonal and physical scales. Temporal orientation items were loaded on one factor, creating a one-dimensional scale. Control items were factored into internal and external control scales. Cronbach's alpha coefficients for the scales ranged from 0.76-0.88. Interpersonal space preference, health temporal orientation, and perceived internal control scales each were predictive of mammography screening adherence. The three tested scales were reliable and valid. Scales, on average, did not differ between African American and Caucasian populations. These scales may be useful in future investigations aimed at increasing mammography screening in African American and Caucasian women.
Measurement of compressed breast thickness by optical stereoscopic photogrammetry.
Tyson, Albert H; Mawdsley, Gordon E; Yaffe, Martin J
2009-02-01
The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.
Bellolio, Enrique; Pineda, Viviana; Burgos, María Eugenia; Iriarte, M José; Becker, Renato; Araya, Juan Carlos; Villaseca, Miguel; Mardones, Noldy
2015-12-01
To validate the BIRADS in mammography, the calculation of its predictive value in each center is required, as recommended by the American College of Radiology. To determine the predictive value of the BIRADS system in our center. All ultrasound guided needle percutaneous biopsies, performed at our center between 2006 and 2010 were reviewed. Predictive value, sensitivity, specificity and diagnostic accuracy of BIRADS were calculated, with a confidence interval of 95%. Of 1,313 biopsies available, 1,058 met the inclusion criteria. Fifty eight percent of biopsies were performed to women with mammographies classified as BIRADS 4 or 5. The presence of cancer in mammographies classified as BIRADS 0 was 4%. The prevalence of cancer for mammographies BIRADS 1, 2, 3, 4 and 5 were 0, 3, 2.7, 17.7 and 72.4% respectively. The positive and negative predictive values of BIRADS classification were 55 and 92 % respectively. In our institution BIRADS classification 4 and 5 has a high positive predictive value for detecting cancer as in developed countries.
Measurement of compressed breast thickness by optical stereoscopic photogrammetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyson, Albert H.; Mawdsley, Gordon E.; Yaffe, Martin J.
2009-02-15
The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of themore » breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.« less
Partik, B; Mallek, R; Rudas, M; Pokieser, P; Wunderbaldinger, P; Helbich, T H
2001-11-01
The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS(R) classification. Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92 %, 89 %, 80 %, 96 % and 90 %, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2 % (2/11) of suspicious lesions. In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence.
Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel
2017-10-01
Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.
Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.
2015-01-01
Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [−0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. PMID:26324395
The Influence of Breast Self-Examination on Subsequent Mammography Participation
Jelinski, Susan E.; Maxwell, Colleen J.; Onysko, Jay; Bancej, Christina M.
2005-01-01
Objectives. We evaluated whether breast self-examination (BSE) influences subsequent mammography participation. Methods. We evaluated associations between BSE and subsequent mammography participation, adjusting for baseline screening behaviors and sociodemographic, health, and lifestyle characteristics, among women aged 40 years and older using data from the longitudinal Canadian National Population Health Survey. Results. Regular performance of BSE at baseline was not associated with receipt of a recent mammogram at follow-up among all women (adjusted odds ratio [OR]=1.01; 95% confidence interval [CI]= 0.75, 1.35) or with mammography uptake among the subgroup of women reporting never use at baseline (adjusted OR=0.78; 95% CI=0.50, 1.22). Conclusions. The lack of association between performance of BSE and subsequent mammography participation suggests that not recommending BSE is unlikely to influence mammography participation. PMID:15727985
Molina, Yamile; Ornelas, India J; Doty, Sarah L; Bishop, Sonia; Beresford, Shirley A A; Coronado, Gloria D
2015-10-01
Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography intentions. Theory suggests that family/friend recommendations increase perceived mammography norms (others believe a woman should obtain a mammogram) and support (others will help her obtain a mammogram), which in turn increase mammography intentions and use. We tested these hypotheses with data from the ¡Fortaleza Latina! study, a randomized controlled trial including 539 Latinas in Washington State. Women whose family/friend recommended they get a mammogram within the last year were more likely to report mammography intentions, norms and support. Perceived mammography norms mediated the relationship between family/friend recommendations and intentions, Mediated Effect = 0.38, 95%CI [0.20, 0.61], but not support, Mediated Effect = 0.002, 95%CI [-0.07, 0.07]. Our findings suggest perceived mammography norms are a potential mechanism underlying the effect of family/friend recommendations on mammography use among Latinas. Our findings make an important contribution to theory about the associations of social interactions, perceptions and health behaviors. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Cheung, Yun-Chung; Lin, Yu-Ching; Wan, Yung-Liang; Yeow, Kee-Min; Huang, Pei-Chin; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chang, Chee-Jen
2014-10-01
To analyse the accuracy of dual-energy contrast-enhanced spectral mammography in dense breasts in comparison with contrast-enhanced subtracted mammography (CESM) and conventional mammography (Mx). CESM cases of dense breasts with histological proof were evaluated in the present study. Four radiologists with varying experience in mammography interpretation blindly read Mx first, followed by CESM. The diagnostic profiles, consistency and learning curve were analysed statistically. One hundred lesions (28 benign and 72 breast malignancies) in 89 females were analysed. Use of CESM improved the cancer diagnosis by 21.2 % in sensitivity (71.5 % to 92.7 %), by 16.1 % in specificity (51.8 % to 67.9 %) and by 19.8 % in accuracy (65.9 % to 85.8 %) compared with Mx. The interobserver diagnostic consistency was markedly higher using CESM than using Mx alone (0.6235 vs. 0.3869 using the kappa ratio). The probability of a correct prediction was elevated from 80 % to 90 % after 75 consecutive case readings. CESM provided additional information with consistent improvement of the cancer diagnosis in dense breasts compared to Mx alone. The prediction of the diagnosis could be improved by the interpretation of a significant number of cases in the presence of 6 % benign contrast enhancement in this study. • DE-CESM improves the cancer diagnosis in dense breasts compared with mammography. • DE-CESM shows greater consistency than mammography alone by interobserver blind reading. • Diagnostic improvement of DE-CESM is independent of the mammographic reading experience.
Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita
2017-11-01
Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed breast cancer, with a higher PPV. © RSNA, 2017.
Breast cancer screening using tomosynthesis in combination with digital mammography.
Friedewald, Sarah M; Rafferty, Elizabeth A; Rose, Stephen L; Durand, Melissa A; Plecha, Donna M; Greenberg, Julianne S; Hayes, Mary K; Copit, Debra S; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Miller, Dave P; Conant, Emily F
2014-06-25
Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4% (difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2% (difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). Addition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes.
[Mammography screening of breast cancer in Tunisia. Results of first experience].
Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi
2003-01-01
This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.
Transformative learning theory: facilitating mammography screening in rural women.
Purtzer, Mary Anne; Overstreet, Lindsey
2014-03-01
To use transformative learning to investigate what experiences serve as catalysts for mammography screening, the cognitive and affective responses that result from the catalyst, and how screening behavior is impacted. A descriptive qualitative study. Southeastern Wyoming. 25 low-income, rural women aged 40 years and older. Four focus group interviews. Cancer experiences triggered universal responses of fear by screeners and nonscreeners. The manner in which that fear response was interpreted was a critical factor in the facilitation of, or impedance to, screening. Dichotomous interpretations of fear responses provided the context for screening behavior. Immobilizing and isolating experiences were associated with nonscreening behavior, whereas motivation and self-efficacy were associated with screening behavior. Transformative learning theory is a useful framework from which to explain differences in mammography screening behavior. Creating opportunities that facilitate dialogue and critical reflection hold the potential to change immobilizing and isolating frames of reference in nonscreening women. To help women transcend their fear and become self-efficacious, nurses can assess how cancer and the screening experience is viewed and, if indicated, move beyond standard education and offer opportunities for dialogue and critical reflection.
Burnside, Elizabeth S.; Liu, Jie; Wu, Yirong; Onitilo, Adedayo A.; McCarty, Catherine; Page, C. David; Peissig, Peggy; Trentham-Dietz, Amy; Kitchner, Terrie; Fan, Jun; Yuan, Ming
2015-01-01
Rationale and Objectives The discovery of germline genetic variants associated with breast cancer has engendered interest in risk stratification for improved, targeted detection and diagnosis. However, there has yet to be a comparison of the predictive ability of these genetic variants with mammography abnormality descriptors. Materials and Methods Our IRB-approved, HIPAA-compliant study utilized a personalized medicine registry in which participants consented to provide a DNA sample and participate in longitudinal follow-up. In our retrospective, age-matched, case-controlled study of 373 cases and 395 controls who underwent breast biopsy, we collected risk factors selected a priori based on the literature including: demographic variables based on the Gail model, common germline genetic variants, and diagnostic mammography findings according to BI-RADS. We developed predictive models using logistic regression to determine the predictive ability of: 1) demographic variables, 2) 10 selected genetic variants, or 3) mammography BI-RADS features. We evaluated each model in turn by calculating a risk score for each patient using 10-fold cross validation; used this risk estimate to construct ROC curves; and compared the AUC of each using the DeLong method. Results The performance of the regression model using demographic risk factors was not statistically different from the model using genetic variants (p=0.9). The model using mammography features (AUC = 0.689) was superior to both the demographic model (AUC = .598; p<0.001) and the genetic model (AUC = .601; p<0.001). Conclusion BI-RADS features exceeded the ability of demographic and 10 selected germline genetic variants to predict breast cancer in women recommended for biopsy. PMID:26514439
Differential Effects of Social Networks on Mammography Use by Poverty Status.
Yeo, Younsook
2016-01-01
This study examines whether social networks have differential effects on mammography use depending on poverty status. Data were analyzed on US women (40+), employing logistic regression and simple slope analyses for a post hoc probing of moderating effects. Among women not in poverty, living with a spouse/partner and attending church, regardless of frequency, were positively associated with mammography use; family size was negatively associated. Among women living in poverty, mammography showed a positive association only with weekly church attendance. Mammography was negatively associated with health-related social interactions occurring through the Internet. Post hoc probing showed significant moderating effects of poverty on the relationship between online health-related interactions and mammography use. To make the Internet a meaningful health empowerment tool for women in poverty, future research should identify how health-related interactions that occur online affect women in poverty's psychological and behavioral reactions that will contribute to our understanding of why they are discouraged from having mammograms. The mechanisms behind the differential effects of church attendance and poverty status on mammography also need further clarification.
Mammography screening among Arab American women in metropolitan Detroit.
Schwartz, Kendra; Fakhouri, Monty; Bartoces, Monina; Monsur, Joseph; Younis, Amani
2008-12-01
Mammography screening behavior has not been well studied among Middle Eastern immigrant women. We conducted a telephone survey of 365 Arab American women residing in metropolitan Detroit, home to one of the largest populations of Middle Eastern immigrants in the US, to determine prevalence of factors associated with mammography, and attitudes and beliefs regarding mammography screening. Of 365 participants, only five were born in the US. Mean age was 53.2 years (SD 10.8). Two hundred twelve (58.1%) reported having mammogram every 1-2 years; 70% ever had mammogram. Age 50-64 years, having health insurance, married status, being in the US over 10 years, and being Lebanese were associated with mammography every 1-2 years. After adjusting for demographic factors, perceived seriousness of disease, general health motivation, and having fewer barriers were associated with more frequent screening. Appropriate mammography screening is decreased in this group. Targeted outreach regarding screening is appropriate for this population; however, lack of insurance may prevent adequate follow-up.
Development of Wagle Health-Specific Religiousness scale.
Wagle, Ann M; Champion, Victoria L; Russell, Kathleen M; Rawl, Susan M
2009-01-01
African American women have a lower rate of regular mammography screening, resulting in higher incidence of advanced-stage breast cancer at diagnosis and a lower 5-year survival rate as compared with white women. Researchers have demonstrated that several health beliefs relate to mammography screening in African American women, but little attention has been paid to the importance of religiousness. Although some authors have attempted to determine a link between religiousness and health, we lack a valid and reliable instrument to measure religiousness that can be found in the context of health behaviors. The purpose of this article is to describe the development and psychometric testing of the Wagle Health-Specific Religiousness (WHSR) scale, an instrument used to measure religious beliefs and the influence of those beliefs on mammography screening for African American women. A sample of 344 low-income African American women who were nonadherent to mammography at accrual participating in a randomized trial completed the WHSR. Data from this trial were used to determine the validity and reliability of the WHSR. The 19-item WHSR scale had a Cronbach alpha of. 94. Construct validity was supported via factor analysis and analysis of theoretical relationships. Although further testing is warranted, this analysis indicates that the concept of religiousness is an important component of mammography behavior in African American women.
Dissemination of periodic mammography and patterns of use, by birth cohort, in Catalonia (Spain)
Rue, Montserrat; Carles, Misericordia; Vilaprinyo, Ester; Martinez-Alonso, Montserrat; Espinas, Josep-Alfons; Pla, Roger; Brugulat, Pilar
2008-01-01
Background In Catalonia (Spain) breast cancer mortality has declined since the beginning of the 1990s. The dissemination of early detection by mammography and the introduction of adjuvant treatments are among the possible causes of this decrease, and both were almost coincident in time. Thus, understanding how these procedures were incorporated into use in the general population and in women diagnosed with breast cancer is very important for assessing their contribution to the reduction in breast cancer mortality. In this work we have modeled the dissemination of periodic mammography and described repeat mammography behavior in Catalonia from 1975 to 2006. Methods Cross-sectional data from three Catalan Health Surveys for the calendar years 1994, 2002 and 2006 was used. The dissemination of mammography by birth cohort was modeled using a mixed effects model and repeat mammography behavior was described by age and survey year. Results For women born from 1938 to 1952, mammography clearly had a period effect, meaning that they started to have periodic mammograms at the same calendar years but at different ages. The age at which approximately 50% of the women were receiving periodic mammograms went from 57.8 years of age for women born in 1938–1942 to 37.3 years of age for women born in 1963–1967. Women in all age groups experienced an increase in periodic mammography use over time, although women in the 50–69 age group have experienced the highest increase. Currently, the target population of the Catalan Breast Cancer Screening Program, 50–69 years of age, is the group that self-reports the highest utilization of periodic mammograms, followed by the 40–49 age group. A higher proportion of women of all age groups have annual mammograms rather than biennial or irregular ones. Conclusion Mammography in Catalonia became more widely implemented during the 1990s. We estimated when cohorts initiated periodic mammograms and how frequently women are receiving them. These two pieces of information will be entered into a cost-effectiveness model of early detection in Catalonia. PMID:19014679
The influence of social support relationships on mammography screening in African-American women.
Fowler, Barbara Ann
2007-07-01
Evidence indicates that mammography screenings have increased in African-American women who are 50 years of age or older; however, they continue to experience later-stage discovery and poorer survival rates from breast cancer compared to White women. Although research has consistently found that social support relationships affects mammography screening in African-American women, little is known about the preventive health behaviors of individuals in these relationships that may be associated with mammography screening. This study examined that association and found that social support relationships, defined as blood-relatives and extended kinship networks, stressed personal responsibility and accountability for preventive health; therefore, supporting mammography screening. Of perhaps the greatest importance, the relationships emphasized positive strengths of African-American culture and invoked the necessity to confront prior negative experiences in health-care systems. These relationships also negated the fears or fatalistic beliefs about breast cancer that had been perpetuated by myths through informal communication and "deliberate silence" from significant others who had previously discouraged or de-emphasized the importance of mammography screening. Further research is needed to determine if the emphasis on cultural heritage was the only motivator that encouraged personal responsibility for mammography screening.
Campari, Cinzia; Giorgi Rossi, Paolo; Mori, Carlo Alberto; Ravaioli, Sara; Nitrosi, Andrea; Vacondio, Rita; Mancuso, Pamela; Cattani, Antonella; Pattacini, Pierpaolo
2016-04-01
In 2012, the Reggio Emilia Breast Cancer Screening Program introduced digital mammography in all its facilities at the same time. The aim of this work is to analyze the impact of digital mammography introduction on the recall rate, detection rate, and positive predictive value. The program actively invites women aged 45-74 years. We included women screened in 2011, all of whom underwent film-screen mammography, and all women screened in 2012, all of whom underwent digital mammography. Double reading was used for all mammograms, with arbitration in the event of disagreement. A total of 42,240 women underwent screen-film mammography and 45,196 underwent digital mammography. The recall rate increased from 3.3 to 4.4% in the first year of digital mammography (relative recall adjusted by age and round 1.46, 95% CI = 1.37-1.56); the positivity rate for each individual reading, before arbitration, rose from 3 to 5.7%. The digital mammography recall rate decreased during 2012: after 12 months, it was similar to the recall rate with screen-film mammography. The detection rate was similar: 5.9/1000 and 5.2/1000 with screen-film and digital mammography, respectively (adjusted relative detection rate 0.95, 95% CI = 0.79-1.13). The relative detection rate for ductal carcinoma in situ remained the same. The introduction of digital mammography to our organized screening program had a negative impact on specificity, thereby increasing the recall rate. The effect was limited to the first 12 months after introduction and was attenuated by the double reading with arbitration. We did not observe any relevant effects on the detection rate.
The relationship of social support concept and repeat mammography among Iranian women.
Farhadifar, Fariba; Taymoori, Parvaneh; Bahrami, Mitra; Zarea, Shamsy
2015-10-24
Breast cancer ranks as the first most common cancer among the Iranian women. The regular repeat of mammography with 1-2 year intervals leads to the increased efficiency of early detection of breast cancer. The present study examined the predictors of repeat mammography. It was hypothesized that higher social support is connected with mammography repeat. A cross-sectional study was carried out among 400 women 50 years and older in Sanandaj, Iran. Data was collected by the questionnaire including information on socio demographical variables and measuring social support level. Data was analyzed by SPSS16 software. Multiple logistic regression was used to determine the predictive power of demographic variables and dimensions of social support for repeat mammography. Women aged 50-55 years had three times odds of repeat mammography compared to women aged 56-60 years) OR, 3.02). Married women had greater odds of repeat mammography compared to single women (P < 0.006). The probability of repeat mammography in women with higher social support was 0.93 times greater than the women with lower social support (OR, 0.93; 95 % CI, 0.91-0.95; P < 0.0001). Iranian women are less likely repeat mammography than other Asian women. Identifying the associations between perceived social support and repeat mammography may offer detailed information to allow for future study and guide the development of interventions not only for Iranian women but also for similar cultural that received pay too little attention to date in the breast cancer literature.
Kobeissi, Loulou; Samari, Goleen; Telesca, Donatello; Esfandiari, Mahtash; Galal, Osman
2014-01-01
Background Few studies explore factors influencing breast cancer screening and early detection behaviors among immigrant Iranian women residing in the United States. Methods Using a cross-sectional survey, a convenience sample of 319 Iranian-American women was selected to explore the impact of breast cancer knowledge and attitude on screening. A self-administered questionnaire assessed: breast cancer screening knowledge, attitude, and mammography use (ever, previous year and future intention). Results 79 % of the women in the study reported ever-receiving at least one mammogram and 74 % received a mammogram in the past year. Personal attitude had an independent significant effect on: mammography use in the last year, ever use of mammography and future intention to screen. Knowledge and morality-induced attitude influenced screening behavior but not significantly. Conclusion Interventions targeting breast cancer screening among immigrant Iranian women in the US should focus on enhancing personal attitudes in order to influence actual screening behavior. PMID:24096382
Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando
2003-01-01
Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical examination. This testing could impact the management of 16,500 patients in the United States every year. More studies are needed to better define its role in breast cancer detection.
Lapeyrouse, Lisa M; Miranda, Patricia Y; Morera, Osvaldo F; Heyman, Josiah McC; Balcazar, Hector G
2017-04-01
Among Latinas, lacking health insurance and having lower levels of acculturation are associated with disparities in mammography screening. We seek to investigate whether differences in lifetime mammography exist between Latina border residents by health insurance status and health care site (i.e., U.S. only or a combination of U.S. and Mexican health care). Using data from the 2009 to 2010 Ecological Household Study on Latino Border Residents, mammography screening was examined among (n = 304) Latinas >40 years old. While more acculturated women were significantly (p < .05) more likely to report ever having a mammogram than less acculturated women, ever having a mammogram was not predicted by health care site or insurance status. Latinas who utilize multiple systems of care have lower levels of acculturation and health insurance, thus representing an especially vulnerable population for experiencing disparities in mammography screening.
[Quality assurance of fine-needle aspiration cytology of the organized mammography screening].
Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós
2010-08-08
The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (p<0.001). The auditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.
Effectiveness of Computer-Aided Detection in Community Mammography Practice
Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.
2011-01-01
Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with higher breast cancer detection rates or more favorable stage, size, or lymph node status of invasive breast cancer. Conclusion CAD use during film-screen screening mammography in the United States is associated with decreased specificity but not with improvement in the detection rate or prognostic characteristics of invasive breast cancer. PMID:21795668
Frischbier, H J
1994-01-01
The results of screening studies conducted in the United States and in Europe in females between the ages of 40 and 50 are analysed. It is shown, that the results of this study on mortality reduction are less favourable, the poorer the technique of mammography (foregoing of general two-view mammography) and the longer the time interval between two mammography screenings. Arguments are presented, that are brought forward when declining to perform general mammography screening in this age group. The author's own results, obtained in the Hamburg mammography screening study, which included from 1971 to 1986 also premenopausal women, show, that the survival rates of patients below 50 years of age with mammographically detected carcinomas of the breast do not differ from those in patients older than 50 years, according to a relevant age group classification. The advances in the technique of mammography in recent years are analysed on the basis of the author's own patient material. It is evident, that the positive predictive value has been doubled, especially in the age group between 40 and 50. An analysis of the distribution of diagnosed noninvasive carcinomas compared with the invasive carcinomas reveals, that particularly this age group has the highest percentage of identification of prognostically favourable carcinoma stages. Further analyses show, why the randomised European mammography studies could not yield a significant mortality rate improvement. A prerequisite for the inclusion of mammography screening in the legally prescribed early detection of carcinoma examinations, however, are the quality controls, whose realisation, in our health system, will have to be confirmed by the German mammography study.
Mammography Use Among Medicare Beneficiaries After Elimination of Cost Sharing.
Sabatino, Susan A; Thompson, Trevor D; Guy, Gery P; de Moor, Janet S; Tangka, Florence K
2016-04-01
We examined mammography use before and after Medicare eliminated cost sharing for screening mammography in January 2011. Using National Health Interview Survey data, we examined changes in mammography use between 2010 and 2013 among Medicare beneficiaries aged 65-74 years. Logistic regression and predictive margins were used to examine changes in use after adjusting for covariates. In 2013, 74.7% of women reported a mammogram within 2 years, a 3.5 percentage point increase (95% confidence interval, -0.3, 7.2) compared with 2010. Increases occurred among women aged 65-69 years, unmarried women, and women with usual sources of care and 2-5 physician visits in the prior year. After adjustment, mammography use increased in 2013 versus 2010 (74.8% vs. 71.3%, P=0.039). Interactions between year and income, insurance, race, or ethnicity were not significant. There was a modest increase in mammography use from 2010 to 2013 among Medicare beneficiaries aged 65-74 years, possibly consistent with an effect of eliminating Medicare cost sharing during this time. Findings suggest that eliminating cost sharing might increase use of recommended screening services.
Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S
2017-12-01
To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.
Thomas, Eileen; Usher, LaToya
2009-01-01
Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.
Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E
2014-07-01
Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.
Auditing and benchmarks in screening and diagnostic mammography.
Feig, Stephen A
2007-09-01
Radiologists can use outcome data such as cancer size and stage to determine how well their own practice provides benefit to their patients and can use measures such as screening recall rates and positive predictive values to assess how well adverse consequences are being contained. New data on national benchmarks for screening and diagnostic mammography in the United States allow radiologists to evaluate their own performance with respect to their peers. This article discusses recommended outcome values in the United States and Europe, current Mammography Quality Standards Act audit requirements, and Institute of Medicine proposals for future requirements.
Njai, Rashid; Siegel, Paul Z; Miller, Jacqueline W; Liao, Youlian
2011-05-01
The validity of self-reported data for mammography differ by race. We assessed the effect of racial differences in the validity of age-adjusted, self-reported mammography use estimates from the Behavioral Risk Factor Surveillance System (BRFSS) from 1995 through 2006 to determine whether misclassification (inaccurate survey question response) may have obscured actual racial disparities. We adjusted BRFSS mammography use data for age by using 2000 census estimates and for misclassification by using the following formula: (estimated prevalence - 1 + specificity) / (sensitivity + specificity - 1). We used values reported in the literature for the formula (sensitivity = 0.97 for both black and white women, specificity = 0.49 and 0.62, respectively, for black and white women). After adjustment for misclassification, the percentage of women aged 40 years or older in 1995 who reported receiving a mammogram during the previous 2 years was 54% among white women and 41% among black women, compared with 70% among both white and black women after adjustment for age only. In 2006, the percentage after adjustment for misclassification was 65% among white women and 59% among black women compared with 77% among white women and 78% among black women after adjustment for age only. Self-reported data overestimate mammography use - more so for black women than for white women. After adjustment for respondent misclassification, neither white women nor black women had attained the Healthy People 2010 objective (≥ 70%) by 2006, and a disparity between white and black women emerged.
Artificial neural networks in mammography interpretation and diagnostic decision making.
Ayer, Turgay; Chen, Qiushi; Burnside, Elizabeth S
2013-01-01
Screening mammography is the most effective means for early detection of breast cancer. Although general rules for discriminating malignant and benign lesions exist, radiologists are unable to perfectly detect and classify all lesions as malignant and benign, for many reasons which include, but are not limited to, overlap of features that distinguish malignancy, difficulty in estimating disease risk, and variability in recommended management. When predictive variables are numerous and interact, ad hoc decision making strategies based on experience and memory may lead to systematic errors and variability in practice. The integration of computer models to help radiologists increase the accuracy of mammography examinations in diagnostic decision making has gained increasing attention in the last two decades. In this study, we provide an overview of one of the most commonly used models, artificial neural networks (ANNs), in mammography interpretation and diagnostic decision making and discuss important features in mammography interpretation. We conclude by discussing several common limitations of existing research on ANN-based detection and diagnostic models and provide possible future research directions.
Discriminatory power of common genetic variants in personalized breast cancer diagnosis
NASA Astrophysics Data System (ADS)
Wu, Yirong; Abbey, Craig K.; Liu, Jie; Ong, Irene; Peissig, Peggy; Onitilo, Adedayo A.; Fan, Jun; Yuan, Ming; Burnside, Elizabeth S.
2016-03-01
Technology advances in genome-wide association studies (GWAS) has engendered optimism that we have entered a new age of precision medicine, in which the risk of breast cancer can be predicted on the basis of a person's genetic variants. The goal of this study is to evaluate the discriminatory power of common genetic variants in breast cancer risk estimation. We conducted a retrospective case-control study drawing from an existing personalized medicine data repository. We collected variables that predict breast cancer risk: 153 high-frequency/low-penetrance genetic variants, reflecting the state-of-the-art GWAS on breast cancer, mammography descriptors and BI-RADS assessment categories in the Breast Imaging Reporting and Data System (BI-RADS) lexicon. We trained and tested naïve Bayes models by using these predictive variables. We generated ROC curves and used the area under the ROC curve (AUC) to quantify predictive performance. We found that genetic variants achieved comparable predictive performance to BI-RADS assessment categories in terms of AUC (0.650 vs. 0.659, p-value = 0.742), but significantly lower predictive performance than the combination of BI-RADS assessment categories and mammography descriptors (0.650 vs. 0.751, p-value < 0.001). A better understanding of relative predictive capability of genetic variants and mammography data may benefit clinicians and patients to make appropriate decisions about breast cancer screening, prevention, and treatment in the era of precision medicine.
Shen, S; Zhou, Y; Xu, Y; Zhang, B; Duan, X; Huang, R; Li, B; Shi, Y; Shao, Z; Liao, H; Jiang, J; Shen, N; Zhang, J; Yu, C; Jiang, H; Li, S; Han, S; Ma, J; Sun, Q
2015-03-17
Chinese women tend to have small and dense breasts and ultrasound is a common method for breast cancer screening in China. However, its efficacy and cost comparing with mammography has not been evaluated in randomised trials. At 14 breast centres across China during 2008-2010, 13 339 high-risk women aged 30-65 years were randomised to be screened by mammography alone, ultrasound alone, or by both methods at enrollment and 1-year follow-up. A total of 12 519 and 8692 women underwent the initial and second screenings, respectively. Among the 30 cancers (of which 15 were stage 0/I) detected, 5 (0.72/1000) were in the mammography group, 11 (1.51/1000) in the ultrasound group, and 14 (2.02/1000) in the combined group (P=0.12). In the combined group, ultrasound detected all the 14 cancers, whereas mammography detected 8, making ultrasound more sensitive (100 vs 57.1%, P=0.04) with a better diagnostic accuracy (0.999 vs 0.766, P=0.01). There was no difference between mammography and ultrasound in specificity (100 vs 99.9%, P=0.51) and positive predictive value (72.7 vs 70.0%; P=0.87). To detect one cancer, the costs of ultrasound, mammography, and combined modality were $7876, $45 253, and $21 599, respectively. Ultrasound is superior to mammography for breast cancer screening in high-risk Chinese women.
Mammography facilities are accessible, so why is utilization so low?
Mobley, Lee R; Kuo, Tzy-Mey May; Clayton, Laurel J; Evans, W Douglas
2009-08-01
This study examines new socio-ecological variables reflecting community context as predictors of mammography use. The conceptual model is a hybrid of traditional health-behavioral and socio-ecological constructs with an emphasis on spatial interaction among women and their environments, differentiating between several levels of influence for community context. Multilevel probability models of mammography use are estimated. The study sample includes 70,129 women with traditional Medicare fee-for-service coverage for inpatient and outpatient services, drawn from the SEER-Medicare linked data. The study population lives in heterogeneous California, where mammography facilities are dense but utilization rates are low. Several contextual effects have large significant impacts on the probability of mammography use. Women living in areas with higher proportions of elderly in poverty are 33% less likely to use mammography. However, dually eligible women living in these poor areas are 2% more likely to use mammography than those without extra assistance living in these areas. Living in areas with higher commuter intensity, higher violent crime rates, greater land use mix (urbanicity), or more segregated Hispanic communities exhibit -14%, -1%, -6%, and -3% (lower) probability of use, respectively. Women living in segregated American Indian communities or in communities where more elderly women live alone exhibit 16% and 12% (higher) probability of use, respectively. Minority women living in more segregated communities by their minority are more likely to use mammography, suggesting social support, but this is significant for Native Americans only. Women with disability as their original reason for entitlement are found 40% more likely to use mammography when they reside in communities with high commuter intensity, suggesting greater ease of transportation for them in these environments. Socio-ecological variables reflecting community context are important predictors of mammography use in insured elderly populations, often with larger magnitudes of effect than personal characteristics such as race or ethnicity (-3% to -7%), age (-2%), recent address change (-7%), disability (-5%) or dual eligibility status (-1%). Better understanding of community factors can enhance cancer control efforts.
Borrayo, Evelinn A
2004-07-01
The need exists to educate and motivate medically disadvantaged Latinas to engage in regular mammography screening to reduce their high breast cancer (BC) mortality risk due to the illness' late detection. Qualitative research methods [e.g., focus groups, key informants] were primarily used during the basic and formative research phases in preproducing and producing a breast cancer educational video for low-literacy Latinas. An 8-min video was created in an Entertainment-Education soap opera format. The purpose of the video is to create awareness about breast cancer and to motivate low-literacy Latinas who are at the precontemplation stage of behavior change to consider engaging in mammography screening. Thus, the video presents a compelling story of a Latina with whom the target audience can identify and become involved with the unfolding events of her story as she realizes her risk for breast cancer and struggles with the decision to engage in mammography. The content and format of the video include culturally relevant clues and modeling to influence Latinas' cognitive and subjective processes involved in making the decision to change. Complex attitudinal and behavioral issues can be effectively targeted to decrease the influence that psychological barriers exert in Latinas low breast cancer screening rates. Copyright 2004 The Institute for Cancer Prevention and Elsevier Inc.
Cancer preventive screening: A cross-border comparison of United States and Canadian Chinese women
Tu, Shin-Ping; Jackson, Sara L.; Yasui, Yutaka; Deschamps, Michéle; Hislop, T. Gregory; Taylor, Vicky M.
2006-01-01
Objective To compare screening mammography and Pap testing among Chinese women in Seattle, Washington to Vancouver, and British Columbia. Methods Using community-based sampling methods, trilingual female interviewers surveyed Chinese women in Seattle and Vancouver. Multiple preventive health behaviors and health care access variables were assessed. Mammography analysis included 409 women aged 50–74 years. Pap testing analysis included 973 women aged 20–69 years. Main outcome measures were ever use and use in the last 2 years of screening mammography and Pap testing. Results Chinese women in Vancouver were younger, more educated and fluent in English. Unadjusted rates of mammography and Pap testing were similar between the two cities. Provider type was consistently associated with screening in both cities; female providers had the highest rates and Chinese male providers the lowest. Adjusted logistic regression analysis demonstrated similar mammography use in the two cities. However, for Pap testing, women in Seattle had higher odds of screening compared to Vancouver. Conclusion Despite universal health care coverage and baseline characteristics typically associated with greater utilization of preventive screening services, Chinese women in Vancouver did not have higher rates of screening mammography and Pap testing compared to Chinese women in Seattle. PMID:15916991
Kwok, Cannas; Endrawes, Gihane; Lee, Chun Fan
2016-01-01
Arabic women have been consistently reported as having remarkably low participation rates in breast cancer screening measures in their home countries and after migration to Western countries. Little is known about the screening behaviors of Arabic women in Australia. This study aimed to report breast cancer screening practices among Arabic women in Australia and to examine the relationship between (1) demographic factors and (2) the Arabic version of the Breast Cancer Screening Beliefs Questionnaire (BCSBQ) score and women's breast screening behaviors. A descriptive cross-sectional method was used. Both English and Arabic versions of the BCSBQ were administered to the 251 Arabic Australian women 18 years or older who participated in the study. The majority of participants (62.9%-92%) had heard of breast awareness, clinical breast examination, and mammography. However, only 7.6% practiced breast awareness monthly, 21.4% had undergone clinical breast examination annually, and 40.3% had biannual mammography. Length of stay in Australia, being retired, and being unemployed were positively associated with the recommended performance of breast awareness and mammography. In terms of BCSBQ scores, women who engaged in the 3 screening practices had significantly higher scores on the attitudes to health check-ups and barriers to mammography subscales. Attitudes toward health check-ups and perceived barriers to mammography were important determinants of breast cancer screening practices among Arabic Australian women. To fully understand barriers discouraging Arabic Australian women from participating in breast cancer screening practices, efforts should be focused on specific subgroup (ie, working group) of Arabic Australian women.
Joseph, Galen; Burke, Nancy J.; Tuason, Noe; Barker, Judith C.; Pasick, Rena J.
2010-01-01
This article describes how the social context of transculturation (cultural change processes) and transmigration (migration in which relationships are sustained across national boundaries) can directly influence use of mammography screening. The authors conducted semistructured interviews with Latino and Filipino academics and social service providers and with U.S.-born and immigrant Latinas and Filipinas to explore direct and indirect influences of social context on health behavior (Behavioral Constructs and Culture in Cancer Screening study). Iterative analyses identified themes of the transcultural domain: colonialism, immigration, discrimination, and therapeutic engagement. In this domain, the authors examine two key behavioral theory constructs, perceptions of susceptibility to illness and perceptions of benefits of preventive medical care. The findings raise concerns about interventions to promote mammography screening primarily based on provision of scientific information. The authors conclude that social context affects behavior directly rather than exclusively through beliefs as behavioral theory implies and that understanding contextual influences, such as transculturation, points to different forms of intervention. PMID:19805792
2008-03-01
dual view mammography with anticipated increased image contrast ; and (4) expectedly improved positive predictive value, especially for...ray source allows for reduced radiation dose as compared to standard dual-view mammography and additionally improves image contrast between soft...clear signal enhancing ~2cm diameter, detailed volume of tracer anterior to the chest wall which corresponded to that seen in the contrast enhanced
Nazzal, Zaher; Sholi, Hisham; Sholi, Suha; Sholi, Mohammad; Lahaseh, Rawya
2016-01-01
Early detection remains the cornerstone of breast cancer control in terms of outcome and survival. Thus far the only breast cancer screening method proven effective is mammography. The awareness of female health care workers (HCW) about breast cancer prevention is of vital importance, as their beliefs and behavior may have a major impact on other women. This study was designed to assess mammography screening uptake among female healthcare workers at primary healthcare centers, and to identify the primary motivators and barriers that affect uptake results. A cross sectional study design was used to assess mammography screening by 299 female healthcare workers who completed a self-administered questionnaire that assessed demographics, screening uptake, motivators and barriers. The mean age was 46 years (within age of risk). The majority (95.1%) demonstrated adequate knowledge about breast cancer and mammography screening and 50% of the participants reported having at least one mammogram; however only 21% of them had regularly scheduled mammograms. The most frequent reported motivator was the perceived benefit that early detection of breast cancer is important for its management (89.6%), followed by the belief that mammography can detect breast cancer before its symptoms appear (84.4%). On the other hand, the most frequent barrier reported was being busy (46.7%), followed by the lack of perceived susceptibility (41.5%). Mammography screening was found to be sub-optimal in a population of HCW's with 50 % stating that they received a mammogram at least once, and a minority reported regular screening. There is a pressing need for educational programs aimed at removing the barriers that limit compliance with recommendations for mammography screening, and to emphasize the importance of early detection in breast cancer treatment. Ensuring the availability and accessibility of screening services, particularly for healthcare workers within their work settings are other important factors that would improve the acceptance and compliance for mammography screening programs.
Ahmadian, Maryam; Samah, Asnarulkhadi Abu; Redzuan, Ma’rof; Emby, Zahid
2012-01-01
Background: Although significant consideration has been devoted to women participation in breast cancer prevention programs, our understanding about the psychosocial factors which influence participation remains incomplete. Method: The study applied a quantitative approach based on the cross-sectional survey design and multistage cluster random sampling. A total of 400 women aged 35-69 years, were surveyed at 4 obstetric and gynecologic clinics affiliated to Tehran University of Medical Sciences in Tehran: the participation levels of 86 women who have had a mammogram were analyzed based on their self-efficacy, belief, social influence, and barriers concerning mammography utilization. Results: Consistent with the study framework, in bivariate analysis, the higher level of women’s participation in breast cancer prevention programs was significantly related to more positive belief about mammography (p< .05), greater social influence on mammography (p< .01) and fewer barriers to mammography (p< .01). Self efficacy (p= .114) was not significantly related to the higher level of participation. Conclusion: Results suggest that women’s participation levels in breast cancer prevention programs might be associated with the specific psychosocial factors on breast cancer preventive behavior such as mammography screening. PMID:22980116
Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.
Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E
1997-01-01
The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.
Patterns and determinants of mammography screening in Lebanese women.
Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M
2017-03-01
The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.
Suzuki, Teppei; Tani, Yuji; Ogasawara, Katsuhiko
2016-07-25
Consistent with the "attention, interest, desire, memory, action" (AIDMA) model of consumer behavior, patients collect information about available medical institutions using the Internet to select information for their particular needs. Studies of consumer behavior may be found in areas other than medical institution websites. Such research uses Web access logs for visitor search behavior. At this time, research applying the patient searching behavior model to medical institution website visitors is lacking. We have developed a hospital website search behavior model using a Bayesian approach to clarify the behavior of medical institution website visitors and determine the probability of their visits, classified by search keyword. We used the website data access log of a clinic of internal medicine and gastroenterology in the Sapporo suburbs, collecting data from January 1 through June 31, 2011. The contents of the 6 website pages included the following: home, news, content introduction for medical examinations, mammography screening, holiday person-on-duty information, and other. The search keywords we identified as best expressing website visitor needs were listed as the top 4 headings from the access log: clinic name, clinic name + regional name, clinic name + medical examination, and mammography screening. Using the search keywords as the explaining variable, we built a binomial probit model that allows inspection of the contents of each purpose variable. Using this model, we determined a beta value and generated a posterior distribution. We performed the simulation using Markov Chain Monte Carlo methods with a noninformation prior distribution for this model and determined the visit probability classified by keyword for each category. In the case of the keyword "clinic name," the visit probability to the website, repeated visit to the website, and contents page for medical examination was positive. In the case of the keyword "clinic name and regional name," the probability for a repeated visit to the website and the mammography screening page was negative. In the case of the keyword "clinic name + medical examination," the visit probability to the website was positive, and the visit probability to the information page was negative. When visitors referred to the keywords "mammography screening," the visit probability to the mammography screening page was positive (95% highest posterior density interval = 3.38-26.66). Further analysis for not only the clinic website but also various other medical institution websites is necessary to build a general inspection model for medical institution websites; we want to consider this in future research. Additionally, we hope to use the results obtained in this study as a prior distribution for future work to conduct higher-precision analysis.
Tani, Yuji
2016-01-01
Background Consistent with the “attention, interest, desire, memory, action” (AIDMA) model of consumer behavior, patients collect information about available medical institutions using the Internet to select information for their particular needs. Studies of consumer behavior may be found in areas other than medical institution websites. Such research uses Web access logs for visitor search behavior. At this time, research applying the patient searching behavior model to medical institution website visitors is lacking. Objective We have developed a hospital website search behavior model using a Bayesian approach to clarify the behavior of medical institution website visitors and determine the probability of their visits, classified by search keyword. Methods We used the website data access log of a clinic of internal medicine and gastroenterology in the Sapporo suburbs, collecting data from January 1 through June 31, 2011. The contents of the 6 website pages included the following: home, news, content introduction for medical examinations, mammography screening, holiday person-on-duty information, and other. The search keywords we identified as best expressing website visitor needs were listed as the top 4 headings from the access log: clinic name, clinic name + regional name, clinic name + medical examination, and mammography screening. Using the search keywords as the explaining variable, we built a binomial probit model that allows inspection of the contents of each purpose variable. Using this model, we determined a beta value and generated a posterior distribution. We performed the simulation using Markov Chain Monte Carlo methods with a noninformation prior distribution for this model and determined the visit probability classified by keyword for each category. Results In the case of the keyword “clinic name,” the visit probability to the website, repeated visit to the website, and contents page for medical examination was positive. In the case of the keyword “clinic name and regional name,” the probability for a repeated visit to the website and the mammography screening page was negative. In the case of the keyword “clinic name + medical examination,” the visit probability to the website was positive, and the visit probability to the information page was negative. When visitors referred to the keywords “mammography screening,” the visit probability to the mammography screening page was positive (95% highest posterior density interval = 3.38-26.66). Conclusions Further analysis for not only the clinic website but also various other medical institution websites is necessary to build a general inspection model for medical institution websites; we want to consider this in future research. Additionally, we hope to use the results obtained in this study as a prior distribution for future work to conduct higher-precision analysis. PMID:27457537
Using automatically extracted information from mammography reports for decision-support
Bozkurt, Selen; Gimenez, Francisco; Burnside, Elizabeth S.; Gulkesen, Kemal H.; Rubin, Daniel L.
2016-01-01
Objective To evaluate a system we developed that connects natural language processing (NLP) for information extraction from narrative text mammography reports with a Bayesian network for decision-support about breast cancer diagnosis. The ultimate goal of this system is to provide decision support as part of the workflow of producing the radiology report. Materials and methods We built a system that uses an NLP information extraction system (which extract BI-RADS descriptors and clinical information from mammography reports) to provide the necessary inputs to a Bayesian network (BN) decision support system (DSS) that estimates lesion malignancy from BI-RADS descriptors. We used this integrated system to predict diagnosis of breast cancer from radiology text reports and evaluated it with a reference standard of 300 mammography reports. We collected two different outputs from the DSS: (1) the probability of malignancy and (2) the BI-RADS final assessment category. Since NLP may produce imperfect inputs to the DSS, we compared the difference between using perfect (“reference standard”) structured inputs to the DSS (“RS-DSS”) vs NLP-derived inputs (“NLP-DSS”) on the output of the DSS using the concordance correlation coefficient. We measured the classification accuracy of the BI-RADS final assessment category when using NLP-DSS, compared with the ground truth category established by the radiologist. Results The NLP-DSS and RS-DSS had closely matched probabilities, with a mean paired difference of 0.004 ± 0.025. The concordance correlation of these paired measures was 0.95. The accuracy of the NLP-DSS to predict the correct BI-RADS final assessment category was 97.58%. Conclusion The accuracy of the information extracted from mammography reports using the NLP system was sufficient to provide accurate DSS results. We believe our system could ultimately reduce the variation in practice in mammography related to assessment of malignant lesions and improve management decisions. PMID:27388877
Qiu, Xiaoming; Mei, Jixin; Yin, Jianjun; Wang, Hong; Wang, Jinqi; Xie, Ming
2017-09-01
This study investigated expression of proliferating cell nuclear antigen (PCNA), proliferation-associated nuclear antigen (Ki-67) and cyclooxygenase-2 (COX-2) in tissues of breast invasive ductal carcinoma, and analyzed the correlations between these indexes and X-ray features in mammography. A total of 90 patients who were admitted to Huangshi Central Hospital and diagnosed as breast invasive ductal carcinoma from January 2014 to January 2016 were selected. The expression of PCNA, Ki-67 and COX-2 in cancer tissues and cancer-adjacent normal tissues of patients were detected by immunohistochemical staining, and X-ray features in mammography of patients were observed. By using Spearman correlation analysis, the correlations between expression of PCNA, Ki-67 and COX-2 and X-ray features in mammography in breast cancer were investigated. As a result, the positive expression rates of PCNA, Ki-67 and COX-2 in cancer tissues of the patient groups were respectively 42.2, 45.6 and 51.1%, which were significantly higher than those in cancer-adjacent normal tissues of the control group (p<0.05). PCNA, Ki-67 and COX-2 expression in cancer tissues of the patient group was associated with clinical staging and lymphatic metastasis (p<0.05), but had no correlation with age and tumor size (p>0.05). PCNA, Ki-67 and COX-2 expression in cancer tissues of the patient group had no correlation with the existence of lumps and localized density-increased shadows (p>0.05), but were associated with manifestations of architectural distortion, calcification as well as skin and nipple depression (p<0.05). Spearman correlation analysis revealed that there was a significantly positive correlation between the expression of PCNA and COX-2 in cancer tissues of the patient group (r=0.676, p<0.05); there was a significantly positive correlation between the expression of Ki-67 and COX-2 (r=0.724, p<0.05); PCNA expression had no obvious correlation with the expression of Ki-67 (p>0.05). In conclusion, PCNA, Ki-67 and COX-2 expression is of great significance in the occurrence, invasion and metastasis of breast invasive ductal carcinoma. There is a strong correlation between PCNA, Ki-67 and COX-2 expression levels and X-ray features in mammography in breast invasive ductal carcinoma. The application of X-ray features in mammography can evaluate the expression levels of PCNA, Ki-67 and COX-2 in tissues of breast invasive ductal carcinoma, thereby prospectively predicting biological behavior of these cancer cells and patient prognosis.
Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.
Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107
Othman, Areej K.; Kiviniemi, Marc T.; Wu, Yow-Wu B.; Lally, Robin M.
2013-01-01
Purpose The purpose of this study was to determine the influence of demographic characteristics, breast cancer knowledge, fatalistic beliefs, health beliefs, and subjective norms on Jordanian women’s intention to participate in mammography screening. Design A cross-sectional survey was used to collect data at 14 comprehensive healthcare centers in Amman and Zarqa, Jordan. A convenience sample of 142 Jordanian women 40 years of age or older with no history of breast cancer and able to read and write in Arabic participated. Methods Self-report surveys included a combination of researcher-designed and existing instruments to measure the study variables. Data were analyzed using descriptive statistics, Pearson’s correlation, t tests, and multiple logistic regression. Findings Jordanian women surveyed lacked knowledge about breast cancer. Social norms and self-efficacy highly influenced these women’s intention to engage in mammography screening. Younger women were more willing to indicate intention to engage in mammographic screening. Conclusions Self-efficacy and the social connectedness of Jordanian society, but not religious beliefs or perceived barriers to screening, influence Jordanian women’s intention to undergo mammography. Future research should examine cultural influences, rather than religious beliefs, and investigate Jordanian women’s potentially unique perspectives on barriers to actual mammography screening behavior. Clinical Relevance The prevalence of mammography screening may be enhanced by focusing interventions on Jordanian women’s support systems and empowering women by providing knowledge and skills needed to engage in the procedure. PMID:22339890
Parish, Susan L; Swaine, Jamie G; Son, Esther; Luken, Karen
2013-01-01
Little information exists on the receipt of mammography by African American women with intellectual disabilities. Given the high rates of mortality from breast cancer among African American women and low screening rates among women with intellectual disabilities, it is important to understand the health screening behavior of this population. We compared rates of mammography receipt among African American and White women with intellectual disabilities (n = 92) living in community settings in one Southeastern state in the United States. Data were collected from women's medical records or abstraction forms obtained from medical practices. Multivariate logistic regressions were modeled for receipt of mammography in one year, one of two years, or both study years (2008- 2009). Covariates included the women's age, living arrangement, severity of impairment, and urban/rural residence location. In 2009, 29% of African American women and 59% of White women in the sample received mammograms. Similar disparities were found for receipt of mammography in either 2008 or 2009 and both 2008 and 2009. These disparities persisted after inclusion of model covariates. White women with intellectual disabilities received mammograms at adjusted rates that were nearly three to five times higher than African American women. African American women with intellectual disabilities receive mammography at significantly lower rates than White women with intellectual disabilities. Assertive measures to improve the screening rates for African American women with intellectual disabilities are urgently needed. Copyright © 2013 Elsevier Inc. All rights reserved.
Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg
2015-04-01
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p < 0.0001) and 0.25 (95% CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98%, a high specificity of 85% and a sensitivity of 74% based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer
2016-06-01
The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.
Validation of a condition-specific measure for women having an abnormal screening mammography.
Brodersen, John; Thorsen, Hanne; Kreiner, Svend
2007-01-01
The aim of this study is to assess the validity of a new condition-specific instrument measuring psychosocial consequences of abnormal screening mammography (PCQ-DK33). The draft version of the PCQ-DK33 was completed on two occasions by 184 women who had received an abnormal screening mammography and on one occasion by 240 women who had received a normal screening result. Item Response Theories and Classical Test Theories were used to analyze data. Construct validity, concurrent validity, known group validity, objectivity and reliability were established by item analysis examining the fit between item responses and Rasch models. Six dimensions covering anxiety, behavioral impact, sense of dejection, impact on sleep, breast examination, and sexuality were identified. One item belonging to the dejection dimension had uniform differential item functioning. Two items not fitting the Rasch models were retained because of high face validity. A sick leave item added useful information when measuring side effects and socioeconomic consequences of breast cancer screening. Five "poor items" were identified and should be deleted from the final instrument. Preliminary evidence for a valid and reliable condition-specific measure for women having an abnormal screening mammography was established. The measure includes 27 "good" items measuring different attributes of the same overall latent structure-the psychosocial consequences of abnormal screening mammography.
An interactive dynamic analysis and decision support software for MR mammography.
Ertaş, Gökhan; Gülçür, H Ozcan; Tunaci, Mehtap
2008-06-01
A fully automated software is introduced to facilitate MR mammography (MRM) examinations and overcome subjectiveness in diagnosis using normalized maximum intensity-time ratio (nMITR) maps. These maps inherently suppress enhancements due to normal parenchyma and blood vessels that surround lesions and have natural tolerance to small field inhomogeneities and motion artifacts. The classifier embedded within the software is trained with normalized complexity and maximum nMITR of 22 lesions and tested with the features of remaining 22 lesions. Achieved diagnostic performances are 92% sensitivity, 90% specificity, 91% accuracy, 92% positive predictive value and 90% negative predictive value. DynaMammoAnalyst shortens evaluation time considerably and reduces inter and intra-observer variability by providing decision support.
Hyman, R B; Greenwald, E S; Hacker, S
1995-01-01
This paper reports results of a survey of 500 health care workers in a private New York City Hospital that assessed knowledge and behaviors in the areas of smoking and cancer, diet and cancer, and breast and cervical cancer screening. Given the small number of knowledge items, the results indicated good knowledge concerning diet and cancer, smoking and cancer, and mammography and Pap test guidelines. Conformity with American Cancer Society guidelines for Pap testing was comparable to national figures, but with women over 50 as likely to obtain Pap smears as younger women. Conformity with mammography guidelines was excellent, although compliance with breast self-examination recommendations was low (25.4%). Of female employees over age 50, 87.4% had ever had mammography and 77.6% reported yearly mammography. Only 19% of the respondents admitted to current smoking. Although methodologic differences made comparison of knowledge of diet and cancer with the work of others difficult, knowledge of the risks of smoking was comparable to levels found in other studies.
Badan, Gustavo Machado; Piato, Sebastião; Roveda, Décio; de Faria Castro Fleury, Eduardo
2016-10-01
The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
External validation of Medicare claims codes for digital mammography and computer-aided detection.
Fenton, Joshua J; Zhu, Weiwei; Balch, Steven; Smith-Bindman, Rebecca; Lindfors, Karen K; Hubbard, Rebecca A
2012-08-01
While Medicare claims are a potential resource for clinical mammography research or quality monitoring, the validity of key data elements remains uncertain. Claims codes for digital mammography and computer-aided detection (CAD), for example, have not been validated against a credible external reference standard. We matched Medicare mammography claims for women who received bilateral mammograms from 2003 to 2006 to corresponding mammography data from the Breast Cancer Surveillance Consortium (BCSC) registries in four U.S. states (N = 253,727 mammograms received by 120,709 women). We assessed the accuracy of the claims-based classifications of bilateral mammograms as either digital versus film and CAD versus non-CAD relative to a reference standard derived from BCSC data. Claims data correctly classified the large majority of film and digital mammograms (97.2% and 97.3%, respectively), yielding excellent agreement beyond chance (κ = 0.90). Claims data correctly classified the large majority of CAD mammograms (96.6%) but a lower percentage of non-CAD mammograms (86.7%). Agreement beyond chance remained high for CAD classification (κ = 0.83). From 2003 to 2006, the predictive values of claims-based digital and CAD classifications increased as the sample prevalences of each technology increased. Medicare claims data can accurately distinguish film and digital bilateral mammograms and mammograms conducted with and without CAD. The validity of Medicare claims data regarding film versus digital mammography and CAD suggests that these data elements can be useful in research and quality improvement. ©2012 AACR.
Phi, Xuan-Anh; Houssami, Nehmat; Hooning, Maartje J; Riedl, Christopher C; Leach, Martin O; Sardanelli, Francesco; Warner, Ellen; Trop, Isabelle; Saadatmand, Sepideh; Tilanus-Linthorst, Madeleine M A; Helbich, Thomas H; van den Heuvel, Edwin R; de Koning, Harry J; Obdeijn, Inge-Marie; de Bock, Geertruida H
2017-11-01
Women with a strong family history of breast cancer (BC) and without a known gene mutation have an increased risk of developing BC. We aimed to investigate the accuracy of screening using annual mammography with or without magnetic resonance imaging (MRI) for these women outside the general population screening program. An individual patient data (IPD) meta-analysis was conducted using IPD from six prospective screening trials that had included women at increased risk for BC: only women with a strong familial risk for BC and without a known gene mutation were included in this analysis. A generalised linear mixed model was applied to estimate and compare screening accuracy (sensitivity, specificity and predictive values) for annual mammography with or without MRI. There were 2226 women (median age: 41 years, interquartile range 35-47) with 7478 woman-years of follow-up, with a BC rate of 12 (95% confidence interval 9.3-14) in 1000 woman-years. Mammography screening had a sensitivity of 55% (standard error of mean [SE] 7.0) and a specificity of 94% (SE 1.3). Screening with MRI alone had a sensitivity of 89% (SE 4.6) and a specificity of 83% (SE 2.8). Adding MRI to mammography increased sensitivity to 98% (SE 1.8, P < 0.01 compared to mammography alone) but lowered specificity to 79% (SE 2.7, P < 0.01 compared with mammography alone). In this population of women with strong familial BC risk but without a known gene mutation, in whom BC incidence was high both before and after age 50, adding MRI to mammography substantially increased screening sensitivity but also decreased its specificity. Copyright © 2017 Elsevier Ltd. All rights reserved.
Seven, Memnun; Bahar, Mine; Akyüz, Aygül; Erdoğan, Hatice
2015-01-01
The workplace has been deemed a suitable location for educating many women at once about cancer screening. To determine how group education about early diagnostic methods for breast and cervical cancer effects women's behavior and readiness to receive mammography and Pap smear. This semi-interventional study was conducted at a textile factory in Istanbul, Turkey. Female workers (n= 125) were included in the study. A participant identification form and knowledge evaluation form developed for this study, along with the transtheoretical model, were used to collect data. A 45-min interactive group education was given to the participants. Upon contacting participants 3 months after group education, 15.4% (n = 11) stated that they had since received a mammogram and 9.8% (n = 7) a Pap smear. As suggested by the transtheoretical model, group education increased participants' readiness to receive cancer screening, along with their knowledge of breast and cervical cancer. Group education positively impacted women's knowledge of cancer and their readiness to receive mammography and Pap smear. Group education can potentially create awareness of cancer screening tests among women and improve their readiness to receive such tests.
Coupling Financial Incentives With Direct Mail in Population-Based Practice.
Slater, Jonathan S; Parks, Michael J; Malone, Michael E; Henly, George A; Nelson, Christina L
2017-02-01
Financial incentives are being used increasingly to encourage a wide array of health behaviors because of their well-established efficacy. However, little is known about how to translate incentive-based strategies to public health practice geared toward improving population-level health, and a dearth of research exists on how individuals respond to incentives through public health communication strategies such as direct mail. This study reports results of a population-based randomized controlled trial testing a direct mail, incentive-based intervention for promoting mammography uptake. The study population was composed of a random sample of Minnesota women enrolled in Medicare fee-for-service and overdue for breast cancer screening. Participants ( N = 18,939) were randomized into three groups: (1) Direct Mail only, (2) Direct Mail plus Incentive, and (3) Control. Both direct mail groups received two mailers with a message about the importance of mammography; however, Mail plus Incentive mailers also offered a $25 incentive for getting a mammogram. Logistic regression analyses measured intervention effects. Results showed the odds for receiving mammography were significantly higher for the Direct Mail plus Incentive group compared with both Direct Mail only and Control groups. The use of incentives also proved to be cost-effective. Additionally, the Direct Mail only group was more likely to receive mammography than the Control group. Findings offer experimental evidence on how the population-based strategy of direct mail coupled with a financial incentive can encourage healthy behavior, as well as how incentive-based programs can be translated into health promotion practice aimed at achieving population-level impact.
The Role of Social Capital in African-American Women's Use of Mammography
Dean, Lorraine; Subramanian, SV; Williams, David R.; Armstrong, Katrina; Charles, Camille Zubrinsky; Kawachi, Ichiro
2014-01-01
Black/African-American women are more likely to get breast cancer at a young age and/or be diagnosed at a late disease stage, pointing to a greater need to promote mammography for Black women at earlier ages than are currently recommended. This study explores how perceived neighborhood social capital, that is, perceptions of how tight-knit a neighborhood is and what power that confers to neighborhood members, relates to use of mammography for Black women in Philadelphia. Living in a community with tight social ties (social cohesion) or that have a collective motivation for community change (collective efficacy) may increase the likelihood that an individual woman in that community will hear health messages from other community members and neighbors (diffusion of information) and will have access to health-related resources that allow them to engage in healthy behaviors. No prior studies have explored the role of social capital in decisions for mammography use. Using multilevel logistic regression, we analyzed self-report of mammography in the past year for 2,586, Black women over age 40 across 381 Philadelphia, Pennsylvania USA census tracts. Our study included individual demographic and aggregates of individual-level social capital data from the Public Health Management Corporation's 2004, 2006, and 2008 Community Health Database waves, and 2000 US Census sociodemographic characteristics. Individual perceptions that a Black woman's neighborhood had high social capital, specifically collective efficacy, had a positive and statistically significant association with mammography use (OR=1.40, CI: 1.05, 1.85). Our findings suggest that an individual woman's perception of greater neighborhood social capital may be related to increased mammography use. Although this analysis could not determine the direction of causality, it suggests that social capital may play a role in cancer preventive screening for African-American women in Philadelphia, which warrants further study. PMID:24581073
Validation of the Spanish Version of the Mammography-Specific Self-Efficacy Scale.
Jerome-D'Emilia, Bonnie; Suplee, Patricia; Akincigil, Ayse
2015-05-01
To consider psychometric estimates of the validity and reliability of the Spanish translation of a mammography-specific self-efficacy scale. A cross-sectional study. Three primarily Hispanic churches and a Hispanic community center in a low-income urban area of New Jersey. 153 low-income Hispanic women aged 40-85 years. The translated scale was administered to participants during a six-month period. Internal consistency, reliability, and construct and predictive validity were assessed. Demographic variables included income and insurance status. Outcome variables included total mammography-specific self-efficacy and having had a mammogram within the past two years. Preliminary evidence of reliability and validity were found, and predictive validity was demonstrated. The health needs of specific populations can be addressed only when research instruments have been appropriately validated and all relevant factors are considered. Diverse groups of low-income women face similar challenges and barriers in their efforts to get screened. Nurses are in an ideal position to help women with preventive care decision making (e.g., screening for breast cancer). Understanding how a woman's level of self-efficacy affects her decision making should be considered when counseling a client.
Badakhsh, Mahin; Balouchi, Abbas; Taheri, Safiyeh; Bouya, Salehoddin; Ahmadidarehsima, Sudabeh; Aminifard, Mohammadnaem
2018-01-01
Objectives: To determining attitudes and practice regarding breast cancer early detection techniques (breast self-examination (BSE), clinical breast examination (CBE) and mammography) among Iranian woman. Methods: International (PubMed, ISI, and Google Scholar) and national (SID and Magiran) databases were reviewed up to September 2017 to identify articles related to the attitudes and practices of Iranian women concerning breast cancer screening behavior with reference to BSE , CBE and mammography. The screening steps, analysis of quality of the studies and extraction of the papers were performed by two reviewers. Results: Of the 532 studies included initially, 21 performed on 10,521 people were considered eligible. Subjects with a positive attitude toward BSE in various studies were 13.5% to 94.0% with an average of 47.6%. Positive attitudes to CBE and mammography were found in 21.0% and 26.4%, respectively. Participant performance of BSE ranged from 2.6% to 84.7%, with an average of 21.9%. The respective figures for CBE and mammography were 15.8% and 16.7%. Conclusion: Considering the poor performance and low rates for positive attitudes, it is suggested that educational programs should be conducted across the country. PMID:29373873
Intention, Subjective Norms, and Cancer Screening in the Context of Relational Culture
Pasick, Rena J.; Barker, Judith C.; Otero-Sabogal, Regina; Burke, Nancy J.; Joseph, Galen; Guerra, Claudia
2010-01-01
Research targeting disparities in breast cancer detection has mainly utilized theories that do not account for social context and culture. Most mammography promotion studies have used a conceptual framework centered in the cognitive constructs of intention (commonly regarded as the most important determinant of screening behavior), self-efficacy, perceived benefit, perceived susceptibility, and/or subjective norms. The meaning and applicability of these constructs in diverse communities are unknown. The purpose of this study is to inductively explore the social context of Filipina and Latina women (the sociocultural forces that shape people’s day-to-day experiences and that directly and indirectly affect health and behavior) to better understand mammography screening behavior. One powerful aspect of social context that emerged from the findings was relational culture, the processes of interdependence and interconnectedness among individuals and groups and the prioritization of these connections above virtually all else. The authors examine the appropriateness of subjective norms and intentions in the context of relational culture and identify inconsistencies that suggest varied meanings from those intended by behavioral theorists. PMID:19805793
Intention, subjective norms, and cancer screening in the context of relational culture.
Pasick, Rena J; Barker, Judith C; Otero-Sabogal, Regina; Burke, Nancy J; Joseph, Galen; Guerra, Claudia
2009-10-01
Research targeting disparities in breast cancer detection has mainly utilized theories that do not account for social context and culture. Most mammography promotion studies have used a conceptual framework centered in the cognitive constructs of intention (commonly regarded as the most important determinant of screening behavior), self-efficacy, perceived benefit, perceived susceptibility, and/or subjective norms. The meaning and applicability of these constructs in diverse communities are unknown. The purpose of this study is to inductively explore the social context of Filipina and Latina women (the sociocultural forces that shape people's day-to-day experiences and that directly and indirectly affect health and behavior) to better understand mammography screening behavior. One powerful aspect of social context that emerged from the findings was relational culture, the processes of interdependence and interconnectedness among individuals and groups and the prioritization of these connections above virtually all else. The authors examine the appropriateness of subjective norms and intentions in the context of relational culture and identify inconsistencies that suggest varied meanings from those intended by behavioral theorists.
Kinney, Anita Yeomans; Emery, Gwyn; Dudley, William N; Croyle, Robert T
2002-06-01
To examine the relationship between beliefs about God as a controlling force in health and adherence to breast cancer screening among high-risk African American women. Cross-sectional cohort. In-person interviews in rural, southeastern Louisiana and telephone interviews conducted at the University of Utah. 52 females who were members of a large kindred with a BRCA1 mutation; no subjects had breast cancer. Survey through in-person or telephone interviews. Belief in God as a controlling agent over health measured by the God Locus of Health Control (GLHC) scale; screening behaviors measured by self-report. Adherence was based on consensus-approved recommendations for BRCA1 carriers or women at risk of being carriers. Bivariate analysis indicated that presence of a primary care provider and low GLHC scores were associated with seeking clinical breast examination (CBE) and mammography. With the variable "presence of a primary care provider" excluded, GLHC scores were inversely associated with seeking CBE and mammography. African American women at increased risk for breast cancer and with high GLHC scores may have a decreased inclination to adhere to CBE and mammography recommendations. Assessing religious and spiritual beliefs and incorporating belief systems into education and counseling sessions may improve understanding and acceptance of presented material.
Henderson, Louise M.; Benefield, Thad; Bowling, J. Michael; Durham, Danielle; Marsh, Mary W.; Schroeder, Bruce F.; Yankaskas, Bonnie C.
2015-01-01
Objective The purpose of this study was to determine whether the technologist has an effect on the radiologists’ interpretative performance of diagnostic mammography. Materials and Methods Using data from a community based mammography registry from 1994 to 2009, we identified 162,755 diagnostic mammograms interpreted by 286 radiologists and performed by 303 mammographic technologists. We calculated sensitivity, false positive rate, and positive predictive value of biopsy (PPV2) for examinations performed (images taken) by each mammographic technologist, separately for film and digital modalities. We assessed the variability of these performance measures among mammographic technologists, using mixed effects logistic regression and taking into account the clustering of examinations within women, radiologists, and radiology practice. Results Among the 291 technologists performing film examinations, mean sensitivity of the examinations they performed was 83.0% (95% Confidence Interval (CI)=80.8–85.2%), mean false positive rate was 8.5 per 1000 examinations (95%CI: 8.0–9.0%), and mean PPV2 was 27.1% (95%CI: 24.8–29.4). For the 45 technologists performing digital examinations, mean sensitivity of the examinations they performed was 79.6% (95%CI: 73.1–86.2%), mean false positive rate was 8.8 (95%CI: 7.5–10.0%), and mean PPV2 was 23.6% (95%CI: 18.8–28.4%). We found significant variation by technologist in the sensitivity, false positive rate, and PPV2 for film but not digital mammography (p<0.0001 for all 3 film performance measures). Conclusions Our results suggest that the technologist has an influence on radiologists’ performance of diagnostic film mammography but not digital. Future work should examine why this difference by modality exists and determine if similar patterns are observed for screening mammography. PMID:25794085
Secginli, Selda; Nahcivan, Nursen O; Gunes, Gussun; Fernandez, Ritin
2017-08-01
Breast cancer is a major health concern and remains the most common malignancy in women worldwide and in Turkey. Mammography, clinical breast examination (CBE), and breast self-examination (BSE) are recommended methods to detect early breast cancer in women. Many strategies have been developed to increase the rates of mammography, CBE, and BSE among Turkish women. Despite the benefits of breast cancer screening, these modalities are still underutilized by the majority of Turkish women. To systematically review the scientific evidence on the effectiveness of various strategies aimed at improving screening behaviors for breast cancer in Turkish women. A systematic review of the literature published between 2000 and 2015 was conducted, searching 10 databases of Ovid MEDLINE, PubMed, Cochrane CENTRAL Register of Controlled Trials, CINAHL, PsycINFO, Web of Knowledge, Scopus, Google Scholar, ULAKBIM Turkish Medical Database, and Council of Higher Education Thesis Center. Twenty-three studies were included in the final review. The majority of the studies investigated the effects of multiple strategies to improve BSE. Group education comprised educational sessions, printed and audiovisual materials, which significantly improved BSE, CBE, and mammography screening rates at 3 months, 6 months, and 12 months after the intervention. One-to-one education demonstrated no significant difference in BSE rates at 6-month and 12-month follow-up. However, one-to-one education demonstrated significant differences in CBE and mammography rates at the 3-month follow-up. The use of group education comprising a multicomponent intervention demonstrated an increase in breast-screening behaviors among Turkish women. Further research investigating the duration of educational interventions is needed in order to suggest a "dose response." © 2017 Sigma Theta Tau International.
Feasibility study for positron emission mammography.
Thompson, C J; Murthy, K; Weinberg, I N; Mako, F
1994-04-01
A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.
Breast cancer risk from different mammography screening practices.
Bijwaard, Harmen; Brenner, Alina; Dekkers, Fieke; van Dillen, Teun; Land, Charles E; Boice, John D
2010-09-01
Mammography screening is an accepted procedure for early detection of breast tumors among asymptomatic women. Since this procedure involves the use of X rays, it is itself potentially carcinogenic. Although there is general consensus about the benefit of screening for older women, screening practices differ between countries. In this paper radiation risks for these different practices are estimated using a new approach. We model breast cancer induction by ionizing radiation in a cohort of patients exposed to frequent X-ray examinations. The biologically based, mechanistic model provides a better foundation for the extrapolation of risks to different mammography screening practices than empirical models do. The model predicts that the excess relative risk (ERR) doubles when screening starts at age 40 instead of 50 and that a continuation of screening at ages 75 and higher carries little extra risk. The number of induced fatal breast cancers is estimated to be considerably lower than derived from epidemiological studies and from internationally accepted radiation protection risks. The present findings, if used in a risk-benefit analysis for mammography screening, would be more favorable to screening than estimates currently recommended for radiation protection. This has implications for the screening ages that are currently being reconsidered in several countries.
A subset polynomial neural networks approach for breast cancer diagnosis.
O'Neill, T J; Penm, Jack; Penm, Jonathan
2007-01-01
Breast cancer is a very common and serious cancer for women that is diagnosed in one of every eight Australian women before the age of 85. The conventional method of breast cancer diagnosis is mammography. However, mammography has been reported to have poor diagnostic capability. In this paper we have used subset polynomial neural network techniques in conjunction with fine needle aspiration cytology to undertake this difficult task of predicting breast cancer. The successful findings indicate that adoption of NNs is likely to lead to increased survival of women with breast cancer, improved electronic healthcare, and enhanced quality of life.
Lyng, Maria B; Kodahl, Annette R; Binder, Harald; Ditzel, Henrik J
2016-12-01
Mammography is the predominant screening method for early detection of breast cancer, but has limitations and could be rendered more accurate by combination with a blood-based biomarker profile. Circulating microRNAs (miRNAs) are increasingly recognized as strong biomarkers, and we previously developed a 9-miRNA profile using serum and LNA-based qPCR that effectively stratified patients with early stage breast cancer vs. healthy women. To further develop the test into routine clinical practice, we collected serum of women examined by clinical mammography (N = 197) according to standard operational procedures (SOPs) of the Danish Cancer Biobank. The performance of the circulating 9-miRNA profile was analyzed in 116 of these women, including 36 with breast cancer (aged 50-74), following a standardized protocol that mimicked a routine clinical set-up. We confirmed that the profile is significantly different between women with breast cancer and controls (p-value <0.0001), with an AUC of 0.61. Significantly, one woman whose 9-miRNA profile predicted a 73% probability of having breast cancer indeed developed the disease within one year despite being categorized as clinically healthy at the time of blood sample collection and mammography. We propose that this miRNA profile combined with mammography will increase the overall accuracy of early detection of breast cancer. Copyright © 2016 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.
Kitahama, H
1991-05-25
The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area = 0.91) was better than that on film-screen mammography (ROC area = 0.88) (p less than 0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study.
Cost-effectiveness of digital mammography breast cancer screening.
Tosteson, Anna N A; Stout, Natasha K; Fryback, Dennis G; Acharyya, Suddhasatta; Herman, Benjamin A; Hannah, Lucy G; Pisano, Etta D
2008-01-01
The DMIST (Digital Mammography Imaging Screening Trial) reported improved breast cancer detection with digital mammography compared with film mammography in selected population subgroups, but it did not assess the economic value of digital relative to film mammography screening. To evaluate the cost-effectiveness of digital mammography screening for breast cancer. Validated, discrete-event simulation model. Data from DMIST and publicly available U.S. data. U.S. women age 40 years or older. Lifetime. Societal and Medicare. All-film mammography screening; all-digital mammography screening; and targeted digital mammography screening, which is age-targeted digital mammography (for women <50 years of age) and age- and density-targeted digital mammography (for women <50 years of age or women > or =50 years of age with dense breasts). Cost per quality-adjusted life-year (QALY) gained. All-digital mammography screening cost $331,000 (95% CI, $268,000 to $403,000) per QALY gained relative to all-film mammography screening but was more costly and less effective than targeted digital mammography screening. Targeted digital mammography screening resulted in more screen-detected cases of cancer and fewer deaths from cancer than either all-film or all-digital mammography screening, with cost-effectiveness estimates ranging from $26,500 (CI, $21,000 to $33,000) per QALY gained for age-targeted digital mammography to $84,500 (CI, $75,000 to $93,000) per QALY gained for age- and density-targeted digital mammography. In the Medicare population, the cost-effectiveness of density-targeted digital mammography screening varied from a base-case estimate of $97,000 (CI, $77,000 to $131,000) to $257,000 per QALY gained (CI, $91,000 to $536,000) in the alternative-case analyses, in which the sensitivity of film mammography was increased and the sensitivity of digital mammography in women with nondense breasts was decreased. Results were sensitive to the cost of digital mammography and to the prevalence of dense breasts. Results were dependent on model assumptions and DMIST findings. Relative to film mammography, screening for breast cancer by using all-digital mammography is not cost-effective. Age-targeted screening with digital mammography seems cost-effective, whereas density-targeted screening strategies are more costly and of uncertain value, particularly among women age 65 years or older.
Lee, Kunsei; Kim, Hyeongsu; Lee, Jung Hyun; Jeong, Hyoseon; Shin, Soon Ae; Han, Taehwa; Seo, Young Lan; Yoo, Youngbum; Nam, Sang Eun; Park, Jong Heon; Park, Yoo Mi
2016-11-18
The purpose of this study was to determine the benefits and limitations of screening for breast cancer using mammography. Descriptive design with follow-up was used in the study. Data from breast cancer screening and health insurance claim data were used. The study population consisted of all participants in breast cancer screening from 2009 to 2014. Crude detection rate, positive predictive value and sensitivity and specificity of breast cancer screening and, incidence rate of interval cancer of the breast were calculated. The crude detection rate of breast cancer screening per 100,000 participants increased from 126.3 in 2009 to 182.1 in 2014. The positive predictive value of breast cancer screening per 100,000 positives increased from 741.2 in 2009 to 1,367.9 in 2014. The incidence rate of interval cancer of the breast per 100,000 negatives increased from 51.7 in 2009 to 76.3 in 2014. The sensitivities of screening for breast cancer were 74.6% in 2009 and 75.1% in 2014 and the specificities were 83.1% in 2009 and 85.7% in 2014. To increase the detection rate of breast cancer by breast cancer screening using mammography, the participation rate should be higher and an environment where accurate mammography and reading can be performed and reinforcement of quality control are required. To reduce the incidence rate of interval cancer of the breast, it will be necessary to educate women after their 20s to perform self-examination of the breast once a month regardless of participation in screening for breast cancer.
A national cross-sectional study of adherence to timely mammography use in Malta.
Marmarà, Danika; Marmarà, Vincent; Hubbard, Gill
2018-03-27
Routine mammography improves survival. To achieve health benefits, women must attend breast screening regularly at recommended time intervals. Maltese women are routinely invited to undergo mammography at three-year intervals at an organized breast screening programme (MBSP) or can opt to attend a private clinic. Previous research shows that health beliefs, particularly perceived barriers, were the most significant predictors of uptake to the first MBSP invitation. Whether these beliefs and other factors are predictive of adherence with recommended time intervals for mammography at organized or private screening in Malta is unknown. For the first time, this paper explores the predictors for Maltese women screened within or exceeding the recommended three-year frequency in organized or private screening in Malta. Information was obtained from a cross-sectional survey of 404 women, aged 50 to 60 years at the time of their first MBSP invitation, where women's characteristics, knowledge, health beliefs and illness perceptions were compared. The main variable of interest was women's mammography attendance within a three-year interval (ADHERENT) or exceeding three years (NON-ADHERENT). Data were analysed using descriptive statistics, chi-square test, Mann Whitney test, Independent Samples t-test and Shapiro Wilk test. At the time of the survey, 80.2% (n = 324) had been screened within three years (ADHERENT), 5.9% (n = 24) had exceeded the three-year frequency (NON-ADHERENT) while 13.9% (n = 56) never had a mammogram. No significant associations were found between ADHERENT or NON-ADHERENT women in relation to sociodemographic or health status variables (p > 0.05). Knowledge of screening frequency was significantly associated with women's mammography adherence (χ2 = 5.5, p = 0.020). Health beliefs were the strongest significant predictors to describe the variance between ADHERENT and NON-ADHERENT screeners. When Mann Whitney test and Independent Samples t-test were applied on mammography adherence, perceived barriers and cues to action were found to be the most important predictors (p = 0.000, p = 0.039 respectively). To increase routine and timely mammography practices, women who are non-adherent to recommended time frequency guidelines should be targeted, together with their health beliefs, predominantly perceived barriers and cues to action.
Complete internal audit of a mammography service in a reference institution for breast imaging.
Badan, Gustavo Machado; Roveda Júnior, Décio; Ferreira, Carlos Alberto Pecci; de Noronha Junior, Ozeas Alves
2014-01-01
Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS(®), in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
Radiologist Uncertainty and the Interpretation of Screening
Carney, Patricia A.; Elmore, Joann G.; Abraham, Linn A.; Gerrity, Martha S.; Hendrick, R. Edward; Taplin, Stephen H.; Barlow, William E.; Cutter, Gary R.; Poplack, Steven P.; D’Orsi, Carl J.
2011-01-01
Objective To determine radiologists’ reactions to uncertainty when interpreting mammography and the extent to which radiologist uncertainty explains variability in interpretive performance. Methods The authors used a mailed survey to assess demographic and clinical characteristics of radiologists and reactions to uncertainty associated with practice. Responses were linked to radiologists’ actual interpretive performance data obtained from 3 regionally located mammography registries. Results More than 180 radiologists were eligible to participate, and 139 consented for a response rate of 76.8%. Radiologist gender, more years interpreting, and higher volume were associated with lower uncertainty scores. Positive predictive value, recall rates, and specificity were more affected by reactions to uncertainty than sensitivity or negative predictive value; however, none of these relationships was statistically significant. Conclusion Certain practice factors, such as gender and years of interpretive experience, affect uncertainty scores. Radiologists’ reactions to uncertainty do not appear to affect interpretive performance. PMID:15155014
Wang, Shuhong; Merlin, Tracy; Kreisz, Florian; Craft, Paul; Hiller, Janet E
2009-10-01
A systematic review assessed the relative safety and effectiveness of digital mammography compared with film-screen mammography. This study utilised the evidence from the review to examine the economic value of digital compared with film-screen mammography in Australia. A cost-comparison analysis between the two technologies was conducted for the overall population for the purposes of breast cancer screening and diagnosis. In addition, a cost-effectiveness analysis was conducted for the screening subgroups where digital mammography was considered to be more accurate than film-screen mammography. Digital mammography in a screening setting is $11 more per examination than film-screen mammography, and $36 or $33 more per examination in a diagnostic setting when either digital radiography or computed radiography is used. In both the screening and diagnostic settings, the throughput of the mammography system had the most significant impact on decreasing the incremental cost/examination/year of digital mammography. Digital mammography is more expensive than film-screen mammography. Whether digital mammography represents good value for money depends on the eventual life-years and quality-adjusted life-years gained from the early cancer diagnosis. The evidence generated from this study has informed the allocation of public resources for the screening and diagnosis of breast cancer in Australia.
Dutch digital breast cancer screening: implications for breast cancer care.
Timmers, Johanna M; den Heeten, Gerard J; Adang, Eddy M; Otten, Johannes D; Verbeek, André L; Broeders, Mireille J
2012-12-01
In comparison to other European population-based breast cancer screening programmes, the Dutch programme has a low referral rate, similar breast cancer detection and a high breast cancer mortality reduction. The referral rate in the Netherlands has increased over time and is expected to rise further, mainly following nationwide introduction of digital mammography, completed in 2010. This study explores the consequences of the introduction of digital mammography on the balance between referral rate, detection of breast cancer, diagnostic work-up and associated costs. Detailed information on diagnostic work-up (chart review) was obtained from referred women (n = 988) in 2000-06 (100% analogue mammography) and 2007 (75% digital mammography) in Nijmegen, the Netherlands. The average referral rate increased from 15 (2000-06) to 34 (2007) per 1000 women screened. The number of breast cancers detected increased from 5.5 to 7.8 per 1000 screens, whereas the positive predictive value fell from 37% to 23%. A sharp rise in diagnostic work-up procedures and total diagnostic costs was seen. On the other hand, costs of a single work-up slightly decreased, as less surgical biopsies were performed. Our study shows that a low referral rate in combination with the introduction of digital mammography affects the balance between referral rate and detection rate and can substantially influence breast cancer care and associated costs. Referral rates in the Netherlands are now more comparable to other countries. This effect is therefore of value in countries where implementation of digital breast cancer screening has just started or is still under discussion.
Henderson, Louise M.; Benefield, Thad; Marsh, Mary W.; Schroeder, Bruce F.; Durham, Danielle; Yankaskas, Bonnie C.; Bowling, J. Michael
2014-01-01
Purpose To determine whether the mammographic technologist has an effect on the radiologists’ interpretative performance of screening mammography in community practice. Materials and Methods In this institutional review board approved retrospective cohort study, we included Carolina Mammography Registry (CMR) data from 372 radiologists and 356 mammographic technologists from 1994 to 2009 who performed 1,003,276 screening mammograms. Measures of interpretative performance (recall rate, sensitivity, specificity, positive predictive value (PPV1), and cancer detection rate (CDR)) were ascertained prospectively with cancer outcomes collected from the state cancer registry and pathology reports. To determine if the mammographic technologist influenced the radiologists’ performance, we employed mixed effects logistic regression models, including a radiologist-specific random effect and taking into account the clustering of examinations across women, separately for screen-film mammography (SFM) and full field digital mammography (FFDM). Results Of the 356 mammographic technologists included, 343 performed 889,347 SFM examinations and 51 performed 113,929 FFDM examinations, and 38 performed both SFM and FFDM. A total of 4,328 cancers were reported for SFM and 564 cancers for FFDM. The technologists had a statistically significant effect on the radiologists’ recall rate, sensitivity, specificity and CDR for both SFM and FFDM (p-values<0.01). For PPV1, variability by technologist was observed for SFM (p-value<0.0001) but not for FFDM (p-value=0.088). Conclusion The interpretative performance of radiologists in screening mammography varies substantially by the technologist performing the examination. Additional studies should aim to identify technologist characteristics that may explain this variation. PMID:25435185
Schonberg, Mara A; Li, Vicky W; Eliassen, A Heather; Davis, Roger B; LaCroix, Andrea Z; McCarthy, Ellen P; Rosner, Bernard A; Chlebowski, Rowan T; Hankinson, Susan E; Marcantonio, Edward R; Ngo, Long H
2016-12-01
Accurate risk assessment is necessary for decision-making around breast cancer prevention. We aimed to develop a breast cancer prediction model for postmenopausal women that would take into account their individualized competing risk of non-breast cancer death. We included 73,066 women who completed the 2004 Nurses' Health Study (NHS) questionnaire (all ≥57 years) and followed participants until May 2014. We considered 17 breast cancer risk factors (health behaviors, demographics, family history, reproductive factors) and 7 risk factors for non-breast cancer death (comorbidities, functional dependency) and mammography use. We used competing risk regression to identify factors independently associated with breast cancer. We validated the final model by examining calibration (expected-to-observed ratio of breast cancer incidence, E/O) and discrimination (c-statistic) using 74,887 subjects from the Women's Health Initiative Extension Study (WHI-ES; all were ≥55 years and followed for 5 years). Within 5 years, 1.8 % of NHS participants were diagnosed with breast cancer (vs. 2.0 % in WHI-ES, p = 0.02), and 6.6 % experienced non-breast cancer death (vs. 5.2 % in WHI-ES, p < 0.001). Using a model selection procedure which incorporated the Akaike Information Criterion, c-statistic, statistical significance, and clinical judgement, our final model included 9 breast cancer risk factors, 5 comorbidities, functional dependency, and mammography use. The model's c-statistic was 0.61 (95 % CI [0.60-0.63]) in NHS and 0.57 (0.55-0.58) in WHI-ES. On average, our model under predicted breast cancer in WHI-ES (E/O 0.92 [0.88-0.97]). We developed a novel prediction model that factors in postmenopausal women's individualized competing risks of non-breast cancer death when estimating breast cancer risk.
Schonberg, Mara A.; Li, Vicky W.; Eliassen, A. Heather; Davis, Roger B.; LaCroix, Andrea Z.; McCarthy, Ellen P.; Rosner, Bernard A.; Chlebowski, Rowan T.; Hankinson, Susan E.; Marcantonio, Edward R.; Ngo, Long H.
2016-01-01
Purpose Accurate risk assessment is necessary for decision-making around breast cancer prevention. We aimed to develop a breast cancer prediction model for postmenopausal women that would take into account their individualized competing risk of non-breast cancer death. Methods We included 73,066 women who completed the 2004 Nurses’ Health Study (NHS) questionnaire (all ≥57 years) and followed participants until May 2014. We considered 17 breast cancer risk factors (health behaviors, demographics, family history, reproductive factors), 7 risk factors for non-breast cancer death (comorbidities, functional dependency), and mammography use. We used competing risk regression to identify factors independently associated with breast cancer. We validated the final model by examining calibration (expected-to-observed ratio of breast cancer incidence, E/O) and discrimination (c-statistic) using 74,887 subjects from the Women’s Health Initiative Extension Study (WHI-ES; all were ≥55 years and followed for 5 years). Results Within 5 years, 1.8% of NHS participants were diagnosed with breast cancer (vs. 2.0% in WHI-ES, p=0.02) and 6.6% experienced non-breast cancer death (vs. 5.2% in WHI-ES, p<0.001). Using a model selection procedure which incorporated the Akaike Information Criterion, c-statistic, statistical significance, and clinical judgement, our final model included 9 breast cancer risk factors, 5 comorbidities, functional dependency, and mammography use. The model’s c-statistic was 0.61 (95% CI [0.60–0.63]) in NHS and 0.57 (0.55–0.58) in WHI-ES. On average our model under predicted breast cancer in WHI-ES (E/O 0.92 [0.88–0.97]). Conclusions We developed a novel prediction model that factors in postmenopausal women’s individualized competing risks of non-breast cancer death when estimating breast cancer risk. PMID:27770283
NASA Astrophysics Data System (ADS)
Li, Yane; Fan, Ming; Li, Lihua; Zheng, Bin
2017-03-01
This study proposed a near-term breast cancer risk assessment model based on local region bilateral asymmetry features in Mammography. The database includes 566 cases who underwent at least two sequential FFDM examinations. The `prior' examination in the two series all interpreted as negative (not recalled). In the "current" examination, 283 women were diagnosed cancers and 283 remained negative. Age of cancers and negative cases completely matched. These cases were divided into three subgroups according to age: 152 cases among the 37-49 age-bracket, 220 cases in the age-bracket 50- 60, and 194 cases with the 61-86 age-bracket. For each image, two local regions including strip-based regions and difference-of-Gaussian basic element regions were segmented. After that, structural variation features among pixel values and structural similarity features were computed for strip regions. Meanwhile, positional features were extracted for basic element regions. The absolute subtraction value was computed between each feature of the left and right local-regions. Next, a multi-layer perception classifier was implemented to assess performance of features for prediction. Features were then selected according stepwise regression analysis. The AUC achieved 0.72, 0.75 and 0.71 for these 3 age-based subgroups, respectively. The maximum adjustable odds ratios were 12.4, 20.56 and 4.91 for these three groups, respectively. This study demonstrate that the local region-based bilateral asymmetry features extracted from CC-view mammography could provide useful information to predict near-term breast cancer risk.
Gan, Yan Xiang; Lao, Cheng-Kin; Chan, Alexandre
2018-05-08
Breast cancer is the third leading cause of death from cancer among females in Macao, but little is known about local practice of breast cancer screening. The study aims to evaluate breast cancer screening behaviors and to identify the predictors of insufficient knowledge and attitudes towards breast cancer and its screening among female residents. This was a cross-sectional study conducted from April to June 2016 in Macao. Quota sampling of women completed the modified Chinese Breast Cancer Screening Beliefs questionnaire (CBCSB) to assess their breast cancer-related perceptions, screening attitudes and behaviors. Univariate and multivariate logistic regressions were performed to identify the predictors of poor-screening practices, attitudes, knowledge and perceived barriers to mammography. A total of 417 women (mean age±SD: 50.5±5.7) completed surveys, with 160 (38.4%), 196 (47.0%) and 103 (24.7%) women received breast self-examination, clinical breast examination and mammography as recommended, respectively. Nulliparity (OR=2.56, 95% CI = 1.14-5.73) and low education (OR = 1.72, 95% CI = 1.04-2.84) were significantly associated with negative attitude towards health check-ups. Women did not know anyone with breast cancer (OR = 2.30, 95% CI = 1.50-3.55) were more likely to have insufficient knowledge about breast cancer. Low education (OR = 1.95, 95% CI = 1.25-3.04) and not knowing anyone with breast cancer (OR = 2.02, 95% CI = 1.31-3.13) were identified as predictors for perceived barriers to mammography. Recommendations for breast cancer screening are poorly followed by the residents in Macao, and a culturally tailored educational program is urgently needed to raise the public's awareness of the disease and the screening practices.
Block, Lauren D; Jarlenski, Marian P; Wu, Albert W; Bennett, Wendy L
2013-11-01
In 2009, the U.S. Preventive Service Task Force changed its recommendation regarding screening mammography in average-risk women aged 40-49 years. To evaluate the effects of the 2009 recommendation on reported mammogram use in a population-based survey. Secondary data analysis of data collected in the 2006, 2008, and 2010 Behavioral Risk Factor Surveillance System surveys. Women ages 40-74 years in the 50 states and Washington, DC who were not pregnant at time of survey and reported data on mammogram use during the 2006, 2008, or 2010 survey. Mammogram use was compared between women ages 40-49 and women ages 50-74 before and after the recommendation. We performed a difference-in-difference estimation adjusted for access to care, education, race, and health status, and stratified analyses by whether women reported having a routine checkup in the prior year. Reported prevalence of mammogram use in the past year among women ages 40-49 and 50-74 was 53.2 % and 65.2 %, respectively in 2008, and 51.7 % and 62.4 % in 2010. In 2010, mammography use did not significantly decline from 2006-2008 in women ages 40-49 relative to women ages 50-74. There was no reduction in mammography use among younger women in 2010 compared to older women and previous years. Patients and providers may have been hesitant to comply with the 2009 recommendation.
Digital mammography: more microcalcifications, more columnar cell lesions without atypia.
Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J
2011-09-01
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2.6%). In conclusion, since the implementation of full-field digital mammography, more microcalcifications are seen at mammography, more often resulting in core needle biopsies, which especially yields more columnar cell lesions without atypia.
Comparison between breast MRI and contrast-enhanced spectral mammography.
Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy
2015-05-12
The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.
Added Value of Contrast-Enhanced Spectral Mammography in Postscreening Assessment.
Tardivel, Anne-Marie; Balleyguier, Corinne; Dunant, Ariane; Delaloge, Suzette; Mazouni, Chafika; Mathieu, Marie-Christine; Dromain, Clarisse
2016-09-01
To assess the value on diagnostic and treatment management of contrast-enhanced spectral mammography (CESM), as adjunct to mammography (MG) and ultrasound (US) in postscreening in a breast cancer unit for patients with newly diagnosed breast cancer or with suspicious findings on conventional imaging. Retrospective review of routine use of bilateral CESM performed between September 2012 and September 2013 in 195 women with suspicious or undetermined findings on MG and/or US. CESM images were blindly reviewed by two radiologists for BI-RADS(®) assessment and probability of malignancy. Each lesion was definitely confirmed either with histopathology or follow-up. Two hundred and ninety-nine lesions were detected (221 malignant). CESM sensitivity, specificity, positive-predictive value and negative-predictive value were 94% (CI: 89-96%), 74% (CI: 63-83%), 91% (CI: 86-94%) and 81% (CI: 70-89%), respectively, with 18 false positive and 14 false negative. CESM changed diagnostic and treatment strategy in 41 (21%) patients either after detection of additional malignant lesions in 38 patients (19%)-with a more extensive surgery (n = 21) or neo-adjuvant chemotherapy (n = 1)-or avoiding further biopsy for 20 patients with negative CESM. CESM can be performed easily in a clinical assessment after positive breast cancer screening and may change significantly the diagnostic and treatment strategy through breast cancer staging. © 2016 Wiley Periodicals, Inc.
Predictors and patterns of fear of cancer recurrence in breast cancer survivors.
McGinty, Heather L; Small, Brent J; Laronga, Christine; Jacobsen, Paul B
2016-01-01
This prospective, longitudinal study examined fear of cancer recurrence (FCR) among breast cancer survivors having mammograms. FCR was hypothesized to increase prior to the mammogram, decrease from immediately pre- to immediately post-mammogram with negative results, and then increase following the mammogram. The possible presence of different trajectories of FCR was also examined. Based on the cognitive-behavioral model (CBM) of health anxiety, greater perceived risk of recurrence, worse perceived consequences of recurrence, lower treatment efficacy beliefs, lower coping self-efficacy, and more engagement in reassurance-seeking behaviors were hypothesized to be associated with greater FCR across all study time points. Following treatment completion for Stage 0-IIIA breast cancer, 161 women completed the following measures: perceived risk and perceived consequences of recurrence, treatment efficacy beliefs, coping self-efficacy, and reassurance-seeking behaviors. Participants reported FCR at 3 time points before and 3 after the mammogram. Growth curve analysis was used to test for changes in FCR over time and growth mixture modeling examined different trajectories in FCR and the ability of the CBM to predict these trajectories. As hypothesized, FCR significantly changed over time; scores increased prior to the mammogram, decreased immediately following receipt of negative mammography results, and increased during the month following the mammogram. Growth mixture models revealed 2 classes, higher-FCR and lower-FCR, which were predicted by the CBM. These study findings support the use of the CBM in predicting which cancer survivors experience greater FCR and indicates that CBM-driven interventions may prove beneficial for reducing distressing FCR. (c) 2015 APA, all rights reserved).
CR digital mammography: an affordable entry.
Fischer, Cathy
2006-01-01
CR full-field digital mammography (FFDM) has been used extensively in other countries, and it was one of the 4 digital mammography technologies employed in the Digital Mammographic Imaging Screening Trial. Affordability and easy integration with pre-existing mammography systems makes CR FFDM an attractive way to secure the advantages of filmless mammography imaging. CR mammography is true digital mammography--it is merely a different way of acquiring the image. The FDA has recently approved the first CR FFDM system for sale in the United States. At Gundersen Lutheran Health System (La Crosse, Wisconsin), CR FFDM is the most practical technology for realizing the potential everyday clinical benefits of filmless mammography imaging.
Spring, Laura M; Marshall, Megan R; Warner, Erica T
2017-02-01
In 2009, the US Preventive Services Task Force recommended that the decision to initiate screening mammography before age 50 years should be individualized. Herein, the authors examined whether health care providers are communicating regarding mammography decision making with women and whether communication is associated with screening behavior. Data were drawn from the 2011 to 2014 Health Information National Trends Survey (HINTS). A total of 5915 female respondents aged ≥ 40 years who responded to the following question were included: "Has a doctor or other health professional ever told you that you could choose whether or not to have a mammogram?" We used logistic regression to generate odds ratios (ORs) and 95% confidence intervals (95% CIs) for predictors of provider communication and assessed whether provider communication was associated with mammography in the previous 2 years overall and stratified by age. Fewer than 50% of the women reported provider communication regarding mammogram choice. Women who reported provider communication were not found to be more likely to report no mammogram within the past 2 years (OR, 1.07; 95% CI, 0.87-1.31) compared with those who did not. When stratified by 10-year age group, provider communication was associated with a higher likelihood of no mammogram only among women age ≥70 years (OR, 1.64; 95% CI, 1.15-2.34), and was associated with a lower likelihood of no mammogram only among women aged 40 to 49 years (OR, 0.63; 95% CI, 0.43-0.92). Between 2011 and 2014, less than one-half of women received communication regarding mammogram choice despite recommendations from the US Preventive Services Task Force. Provider communication regarding mammogram choice can influence screening behavior, particularly for younger and older women. Cancer 2017;123:401-409. © 2016 American Cancer Society. © 2016 American Cancer Society.
Shapelet analysis of pupil dilation for modeling visuo-cognitive behavior in screening mammography
NASA Astrophysics Data System (ADS)
Alamudun, Folami; Yoon, Hong-Jun; Hammond, Tracy; Hudson, Kathy; Morin-Ducote, Garnetta; Tourassi, Georgia
2016-03-01
Our objective is to improve understanding of visuo-cognitive behavior in screening mammography under clinically equivalent experimental conditions. To this end, we examined pupillometric data, acquired using a head-mounted eye-tracking device, from 10 image readers (three breast-imaging radiologists and seven Radiology residents), and their corresponding diagnostic decisions for 100 screening mammograms. The corpus of mammograms comprised cases of varied pathology and breast parenchymal density. We investigated the relationship between pupillometric fluctuations, experienced by an image reader during mammographic screening, indicative of changes in mental workload, the pathological characteristics of a mammographic case, and the image readers' diagnostic decision and overall task performance. To answer these questions, we extract features from pupillometric data, and additionally applied time series shapelet analysis to extract discriminative patterns in changes in pupil dilation. Our results show that pupillometric measures are adequate predictors of mammographic case pathology, and image readers' diagnostic decision and performance with an average accuracy of 80%.
Houssami, Nehmat; Macaskill, Petra; Bernardi, Daniela; Caumo, Francesca; Pellegrini, Marco; Brunelli, Silvia; Tuttobene, Paola; Bricolo, Paola; Fantò, Carmine; Valentini, Marvi; Ciatto, Stefano
2014-07-01
We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial. STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up. For each screen-reading strategy we calculated the number of detected and non-detected (including interval) cancers, cancer detection rates (CDRs), false positive recall (FPR) measures and incremental CDR relative to a comparator strategy. We estimated the false:true positive (FP:TP) ratio and sensitivity of each mammography screening strategy. Paired binary data were compared using McNemar's test. Amongst 7292 screening participants, there were 65 (including six interval) breast cancers; estimated first-year interval cancer rate was 0.82/1000 screens (95% confidence interval (CI): 0.30-1.79/1000). For single-reading, 35 cancers were detected at both 2D and 2D/3D-mammography, 20 cancers were detected only with 2D/3D-mammography compared with none at 2D-mammography alone (p<0.001) and 10 cancers were not detected. For double-reading, 39 cancers were detected at 2D-mammography and 2D/3D-mammography, 20 were detected only with 2D/3D-mammography compared with none detected at 2D-mammography alone (p<0.001) and six cancers were not detected. The incremental CDR attributable to 2D/3D-mammography (versus 2D-mammography) of 2.7/1000 screens (95% CI: 1.6-4.2) was evident for single and for double-reading. Incremental CDR attributable to double-reading (versus single-reading) of 0.55/1000 screens (95% CI: -0.02-1.4) was evident for 2D-mammography and for 2D/3D-mammography. Estimated FP:TP ratios showed that 2D/3D-mammography screening strategies had more favourable FP to TP trade-off and higher sensitivity, applying single-reading or double-reading, relative to 2D-mammography screening. The evidence we report warrants rethinking of breast screening strategies and should be used to inform future evaluations of 2D/3D-mammography that assess whether or not the estimated incremental detection translates into improved screening outcomes such as a reduction in interval cancer rates. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
BM, Geller; A, Bogart; PA, Carney; EA, Sickles; RA, Smith; B, Monsees; LW, Bassett; DM, Buist; K, Kerlikowske; T, Onega; B, Yankaskas; S, Haneuse; DA, Hill; M, Wallis; DL, Miglioretti
2014-01-01
Purpose Conduct a randomized controlled trial of educational interventions to improve performance of screening mammography interpretation. Materials and Methods We randomly assigned physicians who interpret mammography to one of three groups: (1) self-paced DVD; (2) live, expert-led educational session; or (3) control. The DVD and live interventions used mammography cases of varying difficulty and associated teaching points. Interpretive performance was compared using a pre-/post-test design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall, and each were compared using logistic regression adjusting for pre-test performance. Results 102 radiologists completed all aspects of the trial. After adjustment for pre-intervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than controls (95% confidence interval [CI]: 1.00, 1.81; P=0.050). The odds of improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR]=1.94, 95% CI: 1.24, 3.05; P=0.004) and cancer status (OR=1.81, 95% CI: 1.01, 3.23; P=0.045) were significantly improved for DVD participants compared to controls with no significant change in specificity. For the live-intervention group, specificity was significantly lower than the control group (OR relative to expert recall=0.80; 95% CI: 0.64, 1.00; P=0.048; OR relative to cancer=0.79; 95% CI: 0.65, 0.95; P=0.015). Conclusion In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in mammography interpretive screening performance on a test-set, which could translate into improved clinical interpretative performance. PMID:24848854
Geller, Berta M; Bogart, Andy; Carney, Patricia A; Sickles, Edward A; Smith, Robert; Monsees, Barbara; Bassett, Lawrence W; Buist, Diana M; Kerlikowske, Karla; Onega, Tracy; Yankaskas, Bonnie C; Haneuse, Sebastien; Hill, Deirdre; Wallis, Matthew G; Miglioretti, Diana
2014-06-01
The objective of our study was to conduct a randomized controlled trial of educational interventions that were created to improve performance of screening mammography interpretation. We randomly assigned physicians who interpret mammography to one of three groups: self-paced DVD, live expert-led educational seminar, or control. The DVD and seminar interventions used mammography cases of varying difficulty and provided associated teaching points. Interpretive performance was compared using a pretest-posttest design. Sensitivity, specificity, and positive predictive value (PPV) were calculated relative to two outcomes: cancer status and consensus of three experts about recall. The performance measures for each group were compared using logistic regression adjusting for pretest performance. One hundred two radiologists completed all aspects of the trial. After adjustment for preintervention performance, the odds of improved sensitivity for correctly identifying a lesion relative to expert recall were 1.34 times higher for DVD participants than for control subjects (95% CI, 1.00-1.81; p = 0.050). The odds of an improved PPV for correctly identifying a lesion relative to both expert recall (odds ratio [OR] = 1.94; 95% CI, 1.24-3.05; p = 0.004) and cancer status (OR = 1.81; 95% CI, 1.01-3.23; p = 0.045) were significantly improved for DVD participants compared with control subjects, with no significant change in specificity. For the seminar group, specificity was significantly lower than the control group (OR relative to expert recall = 0.80; 95% CI, 0.64-1.00; p = 0.048; OR relative to cancer status = 0.79; 95% CI, 0.65-0.95; p = 0.015). In this randomized controlled trial, the DVD educational intervention resulted in a significant improvement in screening mammography interpretive performance on a test set, which could translate into improved interpretative performance in clinical practice.
Pandhi, Nancy; Schumacher, Jessica R; Thorpe, Carolyn T; Smith, Maureen A
2016-01-01
Objective The extent of first-contact access to primary care (ie, easy availability when needed) is associated with receiving recommended preventive services. Whether this access benefits patients at risk of preventive services underutilisation, such as those with certain personality characteristics, is unclear. Setting Secondary analysis of the 2003–2006 round of the Wisconsin Longitudinal Study. Participants 6975 respondents who reported a usual provider whose specialty was internal medicine or family medicine. Those reporting not visiting a medical provider in the past 12 months, and those who were uninsured were excluded. Primary outcome measures Receiving mammography, cholesterol testing and influenza vaccination. Adjusted predicted probabilities (aPP) of receiving these services were analysed stratified by personality characteristics overall, and if significant, then interacted with first-contact access. Results Lower conscientiousness as compared with higher conscientiousness predicted less of all 3 preventive services; mammography (aPP 80%; 95% CI (77% to 83%) vs aPP 85%; (95% CI 82% to 87%)), cholesterol testing (88%; (85% to 90%) vs 93% (91% to 94%), and influenza vaccination (62%; (59% to 64%) vs 66%; (63% to 68%)). Lower agreeableness as compared with higher agreeableness predicted less mammography (77%; (73% to 81%) vs 84%; (82% to 87%)) and less influenza vaccination (59%; (56% to 62%) vs 65%; (63% to 68%)). Lower extraversion predicted less cholesterol testing (88%; (86% to 91%) vs (92%; (90% to 94%)). Lower openness to experience predicted less influenza vaccination (59%; (56% to 63%) vs (68%; (65% to 70%)). For agreeableness, these differences in receiving preventive services did not persist when first-contact access to primary care was present. Conclusions Certain personality characteristics predicted receiving less preventive care services. For those with less agreeableness, improved first-contact access to primary care mitigated this effect. If these results are replicated in other studies, primary care offices seeking to improve population health through receiving preventive services should prioritise increasing their first-contact accessibility. PMID:26951211
Cross-national comparison of screening mammography accuracy measures in U.S., Norway, and Spain.
Domingo, Laia; Hofvind, Solveig; Hubbard, Rebecca A; Román, Marta; Benkeser, David; Sala, Maria; Castells, Xavier
2016-08-01
To compare accuracy measures for mammographic screening in Norway, Spain, and the US. Information from women aged 50-69 years who underwent mammographic screening 1996-2009 in the US (898,418 women), Norway (527,464), and Spain (517,317) was included. Screen-detected cancer, interval cancer, and the false-positive rates, sensitivity, specificity, positive predictive value (PPV) for recalls (PPV-1), PPV for biopsies (PPV-2), 1/PPV-1 and 1/PPV-2 were computed for each country. Analyses were stratified by age, screening history, time since last screening, calendar year, and mammography modality. The rate of screen-detected cancers was 4.5, 5.5, and 4.0 per 1000 screening exams in the US, Norway, and Spain respectively. The highest sensitivity and lowest specificity were reported in the US (83.1 % and 91.3 %, respectively), followed by Spain (79.0 % and 96.2 %) and Norway (75.5 % and 97.1 %). In Norway, Spain and the US, PPV-1 was 16.4 %, 9.8 %, and 4.9 %, and PPV-2 was 39.4 %, 38.9 %, and 25.9 %, respectively. The number of women needed to recall to detect one cancer was 20.3, 6.1, and 10.2 in the US, Norway, and Spain, respectively. Differences were found across countries, suggesting that opportunistic screening may translate into higher sensitivity at the cost of lower specificity and PPV. • Positive predictive value is higher in population-based screening programmes in Spain and Norway. • Opportunistic mammography screening in the US has lower positive predictive value. • Screening settings in the US translate into higher sensitivity and lower specificity. • The clinical burden may be higher for women screened opportunistically.
Tice, Jeffrey A.; Cummings, Steven R.; Smith-Bindman, Rebecca; Ichikawa, Laura; Barlow, William E.; Kerlikowske, Karla
2009-01-01
Background Current models for assessing breast cancer risk are complex and do not include breast density, a strong risk factor for breast cancer that is routinely reported with mammography. Objective To develop and validate an easy-to-use breast cancer risk prediction model that includes breast density. Design Empirical model based on Surveillance, Epidemiology, and End Results incidence, and relative hazards from a prospective cohort. Setting Screening mammography sites participating in the Breast Cancer Surveillance Consortium. Patients 1 095 484 women undergoing mammography who had no previous diagnosis of breast cancer. Measurements Self-reported age, race or ethnicity, family history of breast cancer, and history of breast biopsy. Community radiologists rated breast density by using 4 Breast Imaging Reporting and Data System categories. Results During 5.3 years of follow-up, invasive breast cancer was diagnosed in 14 766 women. The breast density model was well calibrated overall (expected–observed ratio, 1.03 [95% CI, 0.99 to 1.06]) and in racial and ethnic subgroups. It had modest discriminatory accuracy (concordance index, 0.66 [CI, 0.65 to 0.67]). Women with low-density mammograms had 5-year risks less than 1.67% unless they had a family history of breast cancer and were older than age 65 years. Limitation The model has only modest ability to discriminate between women who will develop breast cancer and those who will not. Conclusion A breast cancer prediction model that incorporates routinely reported measures of breast density can estimate 5-year risk for invasive breast cancer. Its accuracy needs to be further evaluated in independent populations before it can be recommended for clinical use. PMID:18316752
Ding, Huanjun; Sennung, David; Cho, Hyo-Min; Molloi, Sabee
2016-01-01
Purpose: The positive predictive power for malignancy can potentially be improved, if the chemical compositions of suspicious breast lesions can be reliably measured in screening mammography. The purpose of this study is to investigate the feasibility of quantifying breast lesion composition, in terms of water and lipid contents, with spectral mammography. Methods: Phantom and tissue samples were imaged with a spectral mammography system based on silicon-strip photon-counting detectors. Dual-energy calibration was performed for material decomposition, using plastic water and adipose-equivalent phantoms as the basis materials. The step wedge calibration phantom consisted of 20 calibration configurations, which ranged from 2 to 8 cm in thickness and from 0% to 100% in plastic water density. A nonlinear rational fitting function was used in dual-energy calibration of the imaging system. Breast lesion phantoms, made from various combinations of plastic water and adipose-equivalent disks, were embedded in a breast mammography phantom with a heterogeneous background pattern. Lesion phantoms with water densities ranging from 0% to 100% were placed at different locations of the heterogeneous background phantom. The water density in the lesion phantoms was measured using dual-energy material decomposition. The thickness and density of the background phantom were varied to test the accuracy of the decomposition technique in different configurations. In addition, an in vitro study was also performed using mixtures of lean and fat bovine tissue of 25%, 50%, and 80% lean weight percentages as the background. Lesions were simulated by using breast lesion phantoms, as well as small bovine tissue samples, composed of carefully weighed lean and fat bovine tissues. The water densities in tissue samples were measured using spectral mammography and compared to measurement using chemical decomposition of the tissue. Results: The thickness of measured and known water contents was compared for various lesion configurations. There was a good linear correlation between the measured and the known values. The root-mean-square errors in water thickness measurements were 0.3 and 0.2 mm for the plastic phantom and bovine tissue backgrounds, respectively. Conclusions: The results indicate that spectral mammography can be used to accurately characterize breast lesion composition in terms of their equivalent water and lipid contents. PMID:27782705
Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.
Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime
2014-01-01
The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.
Ethnic Differences in Decisional Balance and Stages of Mammography Adoption
ERIC Educational Resources Information Center
Otero-Sabogal, Regina; Stewart, Susan; Shema, Sarah J.; Pasick, Rena J.
2007-01-01
Behavioral theories developed through research with mainstream, English-speaking populations have been applied to ethnically diverse and underserved communities in the effort to eliminate disparities in early breast cancer detection. This study tests the validity of the transtheoretical model (TTM) decisional balance measure and the application of…
Elezaby, Mai; Li, Geng; Bhargavan-Chatfield, Mythreyi; Burnside, Elizabeth S; DeMartini, Wendy B
2018-05-01
Purpose To determine the utilization and positive predictive value (PPV) of the American College of Radiology (ACR) Breast Imaging Data and Reporting System (BI-RADS) category 4 subdivisions in diagnostic mammography in the National Mammography Database (NMD). Materials and Methods This study involved retrospective review of diagnostic mammography data submitted to the NMD from January 1, 2008 to December 30, 2014. Utilization rates of BI-RADS category 4 subdivisions were compared by year, facility (type, location, census region), and examination (indication, finding type) characteristics. PPV3 (positive predictive value for biopsies performed) was calculated overall and according to category 4 subdivision. The χ 2 test was used to test for significant associations. Results Of 1 309 950 diagnostic mammograms, 125 447 (9.6%) were category 4, of which 33.3% (41 841 of 125 447) were subdivided. Subdivision utilization rates were higher (P < .001) in practices that were community, suburban, or in the West; for examination indication of prior history of breast cancer; and for the imaging finding of architectural distortion. Of 41 841 category 4 subdivided examinations, 4A constituted 55.6% (23 258 of 41 841) of the examinations; 4B, 31.8% (13 302 of 41 841) of the examinations; and 4C, 12.6% (5281 of 41 841) of the examinations. Pathologic outcomes were available in 91 563 examinations, and overall category 4 PPV3 was 21.1% (19 285 of 91 563). There was a statistically significant difference in PPV3 according to category 4 subdivision (P < .001): The PPV of 4A was 7.6% (1274 of 16 784), that of 4B was 22% (2317 of 10 408), and that of 4C was 69.3% (2839 of 4099). Conclusion Although BI-RADS suggests their use, subdivisions were utilized in the minority (33.3% [41 841 of 125 447]) of category 4 diagnostic mammograms, with variability based on facility and examination characteristics. When subdivisions were used, PPV3s were in BI-RADS-specified malignancy ranges. This analysis supports the use of subdivisions in broad practice and, given benefits for patient care, should motivate increased utilization. © RSNA, 2018 Online supplemental material is available for this article.
Kerlikowske, Karla; Scott, Christopher G; Mahmoudzadeh, Amir P; Ma, Lin; Winham, Stacey; Jensen, Matthew R; Wu, Fang Fang; Malkov, Serghei; Pankratz, V Shane; Cummings, Steven R; Shepherd, John A; Brandt, Kathleen R; Miglioretti, Diana L; Vachon, Celine M
2018-06-05
In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Case-control. San Francisco Mammography Registry and Mayo Clinic. 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density. National Cancer Institute.
Do Social Network Characteristics Predict Mammography Screening Practices?
ERIC Educational Resources Information Center
Allen, Jennifer D.; Stoddard, Anne M.; Sorensen, Glorian
2008-01-01
Background: Many breast cancer outreach programs assume that dissemination of information through social networks and provision of social support will promote screening. The authors prospectively examined the relationship between social network characteristics and adherence to screening guidelines. Method: Employed women age 40 years and older…
Potente, Giuseppe; Messineo, Daniela; Maggi, Claudia; Savelli, Sara
2009-03-01
The purpose of this article is to report our practical utilization of dynamic contrast-enhanced magnetic resonance mammography [DCE-MRM] in the diagnosis of breast lesions. In many European centers, was preferred a high-temporal acquisition of both breasts simultaneously in a large FOV. We preferred to scan single breasts, with the aim to combine the analysis of the contrast intake and washout with the morphological evaluation of breast lesions. We followed an interpretation model, based upon a diagnostic algorithm, which combined contrast enhancement with morphological evaluation, in order to increase our confidence in diagnosis. DCE-MRM with our diagnostic algorithm has identified 179 malignant and 41 benign lesions; final outcome has identified 178 malignant and 42 benign lesions, 3 false positives and 2 false negatives. Sensitivity of CE-MRM was 98.3%; specificity, 95.1%; positive predictive value, 98.9%; negative predictive value, 92.8% and accuracy, 97.7%.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.
Comparison between Breast MRI and Contrast-Enhanced Spectral Mammography
Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy
2015-01-01
Background The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. Material/Methods After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1–5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. Results There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Conclusions Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI. PMID:25963880
Contrast-enhanced spectral mammography with a photon-counting detector.
Fredenberg, Erik; Hemmendorff, Magnus; Cederström, Björn; Aslund, Magnus; Danielsson, Mats
2010-05-01
Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another approximately 70%-90% improvement was found to be within reach for an optimized system. Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.
Characterizing the Mammography Technologist Workforce in North Carolina.
Henderson, Louise M; Marsh, Mary W; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F; Bowling, J Michael; Viglione, Cheryl A; Yankaskas, Bonnie C
2015-12-01
Mammography technologists' level of training, years of experience, and feedback on technique may play an important role in the breast-cancer screening process. However, information on the mammography technologist workforce is scant. In 2013, we conducted a survey mailed to 912 mammography technologists working in 224 facilities certified by the Mammography Quality Standards Act in North Carolina. Using standard survey methodology, we developed and implemented a questionnaire on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for nonresponse. We describe and compare lead (administrative responsibilities) and nonlead (supervised by another technologist) mammography technologist characteristics, testing for differences, using t-tests and χ(2) analysis. A total of 433 mammography technologists responded (survey response rate = 47.5%; 95% confidence interval [CI]: 44.2%-50.7%), including 128 lead and 305 nonlead technologists. Most mammography technologists were non-Hispanic, white women; their average age was 48 years. Approximately 93% of lead and nonlead technologists had mammography-specific training, but <4% had sonography certification, and 3% had MRI certification. Lead technologists reported more years of experience performing screening mammography (P = .02) and film mammography (P = .03), more administrative hours (P < .0001), and more workplace autonomy (P = .002) than nonlead technologists. Nonlead technologists were more likely to report performing diagnostic mammograms (P = .0004) or other breast imaging (P = .001), discuss image quality with a peer (P = .013), and have frequent face-to-face interaction with radiologists (P = .03). Our findings offer insights into mammography technologists' training and work experiences, highlighting variability in characteristics of lead versus nonlead technologists. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Characterizing the mammography technologist workforce in North Carolina
Henderson, Louise M.; Marsh, Mary W.; Benefield, Thad; Pearsall, Elizabeth; Durham, Danielle; Schroeder, Bruce F.; Bowling, J. Michael; Viglione, Cheryl A.; Yankaskas, Bonnie C.
2016-01-01
Background Mammography technologists’ level of training, years of experience, and feedback on technique may play an important role in the breast cancer screening process. However, very little information on the mammography technologist workforce exists. Methods In 2013, we conducted a mailed survey to 912 mammography technologists working in 224 Mammography Quality Standards Act accredited facilities in North Carolina. Using standard survey methodology we developed and implemented a questionnaire focused on the education and training, work experiences, and workplace interactions of mammography technologists. We aggregated responses using survey weights to account for non-response. We describe and compare lead (administrative responsibilities) and non-lead (supervised by another technologist) mammography technologist characteristics, testing for differences using t-tests and chi-square tests. Results A total of 433 mammography technologists responded (survey response rate=47.5%; 95% confidence interval:44.2%-50.7%), including 128 lead and 305 non-lead technologists. Most mammography technologists were non-Hispanic, white, females and the average age was 48 years. Approximately 93% of lead and non-lead technologists had mammography specific training but <4% had sonography certification and 3% had MRI certification. Lead technologists reported more years performing screening mammography (p-value=0.02) and film mammography (p-value=0.03), more administrative hours (p-value<0.0001), and more workplace autonomy (p-value=0.002) than non-lead technologists. Non-lead technologists were more likely to report performing diagnostic mammograms (p-value=0.0004) or other breast imaging (p-value=0.001), discuss image quality with a peer (p-value=0.013), and have frequent face-to-face interaction with radiologists (p-value=0.03). Conclusion Our findings offer insights into mammography technologists’ training and work experiences, highlighting variability in technologist characteristics between lead and non-lead technologists. PMID:26614888
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Wang, Yunzhi; Yan, Shiju; Tan, Maxine; Cheng, Samuel; Liu, Hong; Zheng, Bin
2016-03-01
In order to establish a new personalized breast cancer screening paradigm, it is critically important to accurately predict the short-term risk of a woman having image-detectable cancer after a negative mammographic screening. In this study, we developed and tested a novel short-term risk assessment model based on deep learning method. During the experiment, a number of 270 "prior" negative screening cases was assembled. In the next sequential ("current") screening mammography, 135 cases were positive and 135 cases remained negative. These cases were randomly divided into a training set with 200 cases and a testing set with 70 cases. A deep learning based computer-aided diagnosis (CAD) scheme was then developed for the risk assessment, which consists of two modules: adaptive feature identification module and risk prediction module. The adaptive feature identification module is composed of three pairs of convolution-max-pooling layers, which contains 20, 10, and 5 feature maps respectively. The risk prediction module is implemented by a multiple layer perception (MLP) classifier, which produces a risk score to predict the likelihood of the woman developing short-term mammography-detectable cancer. The result shows that the new CAD-based risk model yielded a positive predictive value of 69.2% and a negative predictive value of 74.2%, with a total prediction accuracy of 71.4%. This study demonstrated that applying a new deep learning technology may have significant potential to develop a new short-term risk predicting scheme with improved performance in detecting early abnormal symptom from the negative mammograms.
Prediction of near-term breast cancer risk using a Bayesian belief network
NASA Astrophysics Data System (ADS)
Zheng, Bin; Ramalingam, Pandiyarajan; Hariharan, Harishwaran; Leader, Joseph K.; Gur, David
2013-03-01
Accurately predicting near-term breast cancer risk is an important prerequisite for establishing an optimal personalized breast cancer screening paradigm. In previous studies, we investigated and tested the feasibility of developing a unique near-term breast cancer risk prediction model based on a new risk factor associated with bilateral mammographic density asymmetry between the left and right breasts of a woman using a single feature. In this study we developed a multi-feature based Bayesian belief network (BBN) that combines bilateral mammographic density asymmetry with three other popular risk factors, namely (1) age, (2) family history, and (3) average breast density, to further increase the discriminatory power of our cancer risk model. A dataset involving "prior" negative mammography examinations of 348 women was used in the study. Among these women, 174 had breast cancer detected and verified in the next sequential screening examinations, and 174 remained negative (cancer-free). A BBN was applied to predict the risk of each woman having cancer detected six to 18 months later following the negative screening mammography. The prediction results were compared with those using single features. The prediction accuracy was significantly increased when using the BBN. The area under the ROC curve increased from an AUC=0.70 to 0.84 (p<0.01), while the positive predictive value (PPV) and negative predictive value (NPV) also increased from a PPV=0.61 to 0.78 and an NPV=0.65 to 0.75, respectively. This study demonstrates that a multi-feature based BBN can more accurately predict the near-term breast cancer risk than with a single feature.
Lagerlund, Magdalena; Merlo, Juan; Vicente, Raquel Pérez; Zackrisson, Sophia
2015-01-01
Background and aim The public health impact of population-based mammography screening programs depends on high participation rates. Thus, monitoring participation rates, as well as understanding and considering the factors influencing attendance, is important. With the goal to acquire information on the appropriate level of intervention for increasing screening participation our study aimed to (1) examine whether, over and above individual factors, the neighborhood of residence influences a woman’s mammography non-attendance, and (2) evaluate, whether knowing a woman’s neighborhood of residence would be sufficient to predict non-attendance. Methods We analyze all women invited to mammography screening in 2005–09, residing in the city of Malmö, Sweden. Information regarding mammography screening attendance was linked to data on area of residence, demographic and socioeconomic characteristics available from Statistics Sweden. The influence of individual and neighborhood factors was assessed by multilevel logistic regression analysis with 29,901 women nested within 212 neighborhoods. Results The prevalence of non-attendance among women was 18.3%. After adjusting for individual characteristics, the prevalence in the 212 neighborhoods was 3.6%. Neighborhood of residence had little influence on non-attendance. The multilevel analysis indicates that 8.4% of the total individual differences in the propensity of non-attendance were at the neighborhood level. However, when adjusting for specific individual characteristics this general contextual effect decreased to 1.8%. This minor effect was explained by the sociodemographic characteristic of the neighborhoods. The discriminatory accuracy of classifying women according to their non-attendance was 0.747 when considering only individual level variables, and 0.760 after including neighborhood level as a random effect. Conclusion Our results suggest that neighborhoods of residence in Malmö, Sweden (as defined by small-area market statistics (SAMS) areas) do not condition women’s participation in population based mammography screening. Thus, interventions should be directed to the whole city and target women with a higher risk of non-attendance. PMID:26460609
Melnikow, Joy; Fenton, Joshua J; Whitlock, Evelyn P; Miglioretti, Diana L; Weyrich, Meghan S; Thompson, Jamie H; Shah, Kunal
2016-02-16
Screening mammography has lower sensitivity and specificity in women with dense breasts, who experience higher breast cancer risk. To perform a systematic review of reproducibility of Breast Imaging Reporting and Data System (BI-RADS) density categorization and test performance and clinical outcomes of supplemental screening with breast ultrasonography, magnetic resonance imaging (MRI), and digital breast tomosynthesis (DBT) in women with dense breasts and negative mammography results. MEDLINE, PubMed, EMBASE, and Cochrane database from January 2000 to July 2015. Studies reporting BI-RADS density reproducibility or supplemental screening results for women with dense breasts. Quality assessment and abstraction of 24 studies from 7 countries; 6 studies were good-quality. Three good-quality studies reported reproducibility of BI-RADS density; 13% to 19% of women were recategorized between "dense" and "nondense" at subsequent screening. Two good-quality studies reported that sensitivity of ultrasonography for women with negative mammography results ranged from 80% to 83%; specificity, from 86% to 94%; and positive predictive value (PPV), from 3% to 8%. The sensitivity of MRI ranged from 75% to 100%; specificity, from 78% to 94%; and PPV, from 3% to 33% (3 studies). Rates of additional cancer detection with ultrasonography were 4.4 per 1000 examinations (89% to 93% invasive); recall rates were 14%. Use of MRI detected 3.5 to 28.6 additional cancer cases per 1000 examinations (34% to 86% invasive); recall rates were 12% to 24%. Rates of cancer detection with DBT increased by 1.4 to 2.5 per 1000 examinations compared with mammography alone (3 studies). Recall rates ranged from 7% to 11%, compared with 7% to 17% with mammography alone. No studies examined breast cancer outcomes. Good-quality evidence was sparse. Studies were small and CIs were wide. Definitions of recall were absent or inconsistent. Density ratings may be recategorized on serial screening mammography. Supplemental screening of women with dense breasts finds additional breast cancer but increases false-positive results. Use of DBT may reduce recall rates. Effects of supplemental screening on breast cancer outcomes remain unclear. Agency for Healthcare Research and Quality.
Beckmann, Kerri; Duffy, Stephen W; Lynch, John; Hiller, Janet; Farshid, Gelareh; Roder, David
2015-09-01
To estimate over-diagnosis due to population-based mammography screening using a lead time adjustment approach, with lead time measures based on symptomatic cancers only. Women aged 40-84 in 1989-2009 in South Australia eligible for mammography screening. Numbers of observed and expected breast cancer cases were compared, after adjustment for lead time. Lead time effects were modelled using age-specific estimates of lead time (derived from interval cancer rates and predicted background incidence, using maximum likelihood methods) and screening sensitivity, projected background breast cancer incidence rates (in the absence of screening), and proportions screened, by age and calendar year. Lead time estimates were 12, 26, 43 and 53 months, for women aged 40-49, 50-59, 60-69 and 70-79 respectively. Background incidence rates were estimated to have increased by 0.9% and 1.2% per year for invasive and all breast cancer. Over-diagnosis among women aged 40-84 was estimated at 7.9% (0.1-12.0%) for invasive cases and 12.0% (5.7-15.4%) when including ductal carcinoma in-situ (DCIS). We estimated 8% over-diagnosis for invasive breast cancer and 12% inclusive of DCIS cancers due to mammography screening among women aged 40-84. These estimates may overstate the extent of over-diagnosis if the increasing prevalence of breast cancer risk factors has led to higher background incidence than projected. © The Author(s) 2015.
Associations Between Religion-Related Factors and Breast Cancer Screening Among American Muslims
Padela, Aasim I.; Murrar, Sohad; Adviento, Brigid; Liao, Chuanhong; Hosseinian, Zahra; Peek, Monica; Curlin, Farr
2015-01-01
American Muslims have low rates of mammography utilization, and research suggests that religious values influence their health-seeking behaviors. We assessed associations between religion-related factors and breast cancer screening in this population. A diverse group of Muslim women were recruited from mosques and Muslim organization sites in Greater Chicago to self-administer a survey incorporating measures of fatalism, religiosity, discrimination, and Islamic modesty. 254 surveys were collected of which 240 met age inclusion criteria (40 years of age or older). Of the 240, 72 respondents were Arab, 71 South Asian, 59 African American, and 38 identified with another ethnicity. 77 % of respondents had at least one mammogram in their lifetime, yet 37 % had not obtained mammography within the past 2 years. In multivariate models, positive religious coping, and perceived religious discrimination in healthcare were negatively associated with having a mammogram in the past 2 years, while having a PCP was positively associated. Ever having a mammogram was positively associated with increasing age and years of US residency, and knowing someone with breast cancer. Promoting biennial mammography among American Muslims may require addressing ideas about religious coping and combating perceived religious discrimination through tailored interventions. PMID:24700026
Associations between religion-related factors and breast cancer screening among American Muslims.
Padela, Aasim I; Murrar, Sohad; Adviento, Brigid; Liao, Chuanhong; Hosseinian, Zahra; Peek, Monica; Curlin, Farr
2015-06-01
American Muslims have low rates of mammography utilization, and research suggests that religious values influence their health-seeking behaviors. We assessed associations between religion-related factors and breast cancer screening in this population. A diverse group of Muslim women were recruited from mosques and Muslim organization sites in Greater Chicago to self-administer a survey incorporating measures of fatalism, religiosity, discrimination, and Islamic modesty. 254 surveys were collected of which 240 met age inclusion criteria (40 years of age or older). Of the 240, 72 respondents were Arab, 71 South Asian, 59 African American, and 38 identified with another ethnicity. 77% of respondents had at least one mammogram in their lifetime, yet 37% had not obtained mammography within the past 2 years. In multivariate models, positive religious coping, and perceived religious discrimination in healthcare were negatively associated with having a mammogram in the past 2 years, while having a PCP was positively associated. Ever having a mammogram was positively associated with increasing age and years of US residency, and knowing someone with breast cancer. Promoting biennial mammography among American Muslims may require addressing ideas about religious coping and combating perceived religious discrimination through tailored interventions.
Fukatsu, Hiroshi; Naganawa, Shinji; Yumura, Shinnichiro
2008-04-01
This study was aimed to validate the performance of a novel image compression method using a neural network to achieve a lossless compression. The encoding consists of the following blocks: a prediction block; a residual data calculation block; a transformation and quantization block; an organization and modification block; and an entropy encoding block. The predicted image is divided into four macro-blocks using the original image for teaching; and then redivided into sixteen sub-blocks. The predicted image is compared to the original image to create the residual image. The spatial and frequency data of the residual image are compared and transformed. Chest radiography, computed tomography (CT), magnetic resonance imaging, positron emission tomography, radioisotope mammography, ultrasonography, and digital subtraction angiography images were compressed using the AIC lossless compression method; and the compression rates were calculated. The compression rates were around 15:1 for chest radiography and mammography, 12:1 for CT, and around 6:1 for other images. This method thus enables greater lossless compression than the conventional methods. This novel method should improve the efficiency of handling of the increasing volume of medical imaging data.
Intention, Subjective Norms, and Cancer Screening in the Context of Relational Culture
ERIC Educational Resources Information Center
Pasick, Rena J.; Barker, Judith C.; Otero-Sabogal, Regina; Burke, Nancy J.; Joseph, Galen; Guerra, Claudia
2009-01-01
Research targeting disparities in breast cancer detection has mainly utilized theories that do not account for social context and culture. Most mammography promotion studies have used a conceptual framework centered in the cognitive constructs of intention (commonly regarded as the most important determinant of screening behavior), self-efficacy,…
TL dosimetry for quality control of CR mammography imaging systems
NASA Astrophysics Data System (ADS)
Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.
The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.
Mammography: an update of the EUSOBI recommendations on information for women.
Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor
2017-02-01
This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.
Audit of mammography requests in Abakaliki, South-East Nigeria.
Eni, U E; Ekwedigwe, K C; Sunday-Adeoye, I; Daniyan, Abc; Isikhuemen, M E
2017-03-07
Breast cancer is the leading cancer in women in both developed and developing countries. Screening mammography detects breast cancer even before a lump can be palpated, with better prognosis. The introduction of mammographic technique for screening breast cancer, despite its importance, has been slow to adopt and virtually non-existent in many parts of Sub-Saharan Africa including Nigeria. For this reason, the indications of mammography have not been well defined in our setting. The aim of this study was to audit our mammography requests, with a view to improving its application in our setting. This is a descriptive study carried out on 69 female patients who had mammography at the National Obstetric Fistula Centre, Abakaliki, from January 2014 to December 2015. Findings on clinical examination were entered in a proforma. Mammography was performed in craniocaudal and mediolateral views using the Lorad M-IV (film-screen) mammography machine. Data was analysed using the Statistical Package for Social Sciences (SPSS) version 21. All 69 patients were females. Their mean age was 42.1 ± 11 years. Majority of the patients (69.6%) were between 30 and 49 years. The commonest indication for mammography was breast lump which was found in 46 patients (66.7%). Breast pain was present in 36 (52.2%) of patients. The different Breast Imaging Reporting and Data System (BIRADS) categories were BIRADS 0: 20 (28.99%), BIRADS 1: 8 (11.59%), BIRADS 2: 9 (13.04%), BIRADS 3: 4 (5.8%), BIRADS 4: 19 (27.54%) and BIRADS 5: 9 (13.04%). Diagnostic mammography remains the commonest indication for mammography in our setting. Public awareness, poverty reduction and ready availability of mammography facilities are required to improve screening mammography in our setting.
Consedine, Nathan S
2012-08-01
Disparities in breast screening are well documented. Less clear are differences within groups of immigrant and non-immigrant minority women or differences in adherence to mammography guidelines over time. A sample of 1,364 immigrant and non-immigrant women (African American, English Caribbean, Haitian, Dominican, Eastern European, and European American) were recruited using a stratified cluster-sampling plan. In addition to measuring established predictors of screening, women reported mammography frequency in the last 10 years and were (per ACS guidelines at the time) categorized as never, sub-optimal (<1 screen/year), or adherent (1+ screens/year) screeners. Multinomial logistic regression showed that while ethnicity infrequently predicted the never versus sub-optimal comparison, English Caribbean, Haitian, and Eastern European women were less likely to screen systematically over time. Demographics did not predict the never versus sub-optimal distinction; only regular physician, annual exam, physician recommendation, and cancer worry showed effects. However, the adherent categorization was predicted by demographics, was less likely among women without insurance, a regular physician, or an annual exam, and more likely among women reporting certain patterns of emotion (low embarrassment and greater worry). Because regular screening is crucial to breast health, there is a clear need to consider patterns of screening among immigrant and non-immigrant women as well as whether the variables predicting the initiation of screening are distinct from those predicting systematic screening over time.
Freund, Anat; Cohen, Miri; Azaiza, Faisal
2017-07-04
Studies have shown a lower adherence to health behaviors among women in cultural-ethnic minorities and faith-based communities, especially lower screening attendance for the early detection of breast cancer. This study compares factors related to cancer screening adherence in two distinct cultural-ethnic minorities in Israel: Arab women as a cultural-ethnic minority and Jewish ultra-Orthodox women as a cultural-ethnic faith-based minority. During the year 2014, a total of 398 Jewish ultra-Orthodox women and 401 Arab women between the ages of 40-60, were randomly selected using population-based registries. These women answered questionnaires regarding adherence to mammography and clinical breast examination (CBE), health beliefs and cultural barriers. Arab women adhered more than ultra-Orthodox women to mammography (p < .001) and CBE exams (p < .01). Religious beliefs, exposure barriers and perceived risk were higher among the ultra-Orthodox women, while social barriers, accessibility barriers and perceived severity were higher among the Arab women (p < .01). Adjusting for background factors, higher adherence to CBE and mammography were associated with lower levels of religious beliefs (AOR = 0.90, 95% CI = 0.69-1.17 AOR = 0.62, 95% CI = 0.39-0.82, respectively), perceiving a higher risk of cancer (AOR = 1.93, 95% CI = 1.23-3.04 and AOR = 3.22, 95% CI = 1.53-6.61), and having more fears related to cancer-related losses (AOR = 1.51, 95% CI = 1.19-3.00 and AOR = 1.24, 95% CI = 0.63-1.22). In addition, perceiving greater advantages of CBE was associated with higher adherence to CBE (AOR = 1.82, 95% CI = 1.45-2.29), while not receiving a physician's recommendation was associated with lower adherence to mammography (AOR = 1.82, 95% CI = 1.45-2.29). This study addressed a lacuna in screening behaviors of women from cultural-ethnic and faith-based communities. In order to increase adherence, health care professionals and policymakers should direct their attention to the specific nature of each community.
Design of a sensitive grating-based phase contrast mammography prototype (Conference Presentation)
NASA Astrophysics Data System (ADS)
Arboleda Clavijo, Carolina; Wang, Zhentian; Köhler, Thomas; van Stevendaal, Udo; Martens, Gerhard; Bartels, Matthias; Villanueva-Perez, Pablo; Roessl, Ewald; Stampanoni, Marco
2017-03-01
Grating-based phase contrast mammography can help facilitate breast cancer diagnosis, as several research works have demonstrated. To translate this technique to the clinics, it has to be adapted to cover a large field of view within a limited exposure time and with a clinically acceptable radiation dose. This indicates that a straightforward approach would be to install a grating interferometer (GI) into a commercial mammography device. We developed a wave propagation based optimization method to select the most convenient GI designs in terms of phase and dark-field sensitivities for the Philips Microdose Mammography (PMM) setup. The phase sensitivity was defined as the minimum detectable breast tissue electron density gradient, whereas the dark-field sensitivity was defined as its corresponding signal-to-noise Ratio (SNR). To be able to derive sample-dependent sensitivity metrics, a visibility reduction model for breast tissue was formulated, based on previous research works on the dark-field signal and utilizing available Ultra-Small-Angle X-ray Scattering (USAXS) data and the outcomes of measurements on formalin-fixed breast tissue specimens carried out in tube-based grating interferometers. The results of this optimization indicate the optimal scenarios for each metric are different and fundamentally depend on the noise behavior of the signals and the visibility reduction trend with respect to the system autocorrelation length. In addition, since the inter-grating distance is constrained by the space available between the breast support and the detector, the best way we have to improve sensitivity is to count on a small G2 pitch.
Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment
Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne
2016-01-01
Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Ultrasound has been suggested as a safe adjunct screening tool that can detect breast cancers missed on mammography. We investigated the benefits, harms, cost-effectiveness, and cost burden of ultrasound as an adjunct to mammography compared with mammography alone for screening women at average risk and at high risk for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, EBM Reviews, and the NHS Economic Evaluation Database, from January 1998 to June 2015, for evidence of effectiveness, harms, diagnostic accuracy, and cost-effectiveness. Only studies evaluating the use of ultrasound as an adjunct to mammography in the specified populations were included. We also conducted a cost analysis to estimate the costs in Ontario over the next 5 years to fund ultrasound as an adjunct to mammography in breast cancer screening for high-risk women who are contraindicated for MRI, the current standard of care to supplement mammography. Results No studies in average-risk women met the inclusion criteria of the clinical review. We included 5 prospective, paired cohort studies in high-risk women, 4 of which were relevant to the Ontario context. Adjunct ultrasound identified between 2.3 and 5.9 additional breast cancers per 1,000 screens. The average pooled sensitivity of mammography and ultrasound was 53%, a statistically significant increase relative to mammography alone (absolute increase 13%; P < .05). The average pooled specificity of the combined test was 96%, an absolute increase in the false-positive rate of 2% relative to mammography screening alone. The GRADE for this body of evidence was low. Additional annual costs of using breast ultrasound as an adjunct to mammography for high-risk women in Ontario contraindicated for MRI would range from $15,500 to $30,250 in the next 5 years. Conclusions We found no evidence that evaluated the comparative effectiveness or diagnostic accuracy of screening breast ultrasound as an adjunct to mammography among average-risk women aged 50 years and over. In women at high risk of developing breast cancer, there is low-quality evidence that screening with mammography and adjunct ultrasound detects additional cases of disease, with improved sensitivity compared to mammography alone. Screening with adjunct ultrasound also increases the number of false-positive findings and subsequent biopsy recommendations. It is unclear if the use of screening breast ultrasound as an adjunct to mammography will reduce breast cancer–related mortality among high-risk women. The annual cost burden of using adjunct ultrasound to screen high-risk women who cannot receive MRI in Ontario would be small. PMID:27468326
Decision making and counseling around mammography screening for women aged 80 or older.
Schonberg, Mara A; Ramanan, Radhika A; McCarthy, Ellen P; Marcantonio, Edward R
2006-09-01
Despite uncertain benefit, many women over age 80 (oldest-old) receive screening mammography. To explore decision-making and physician counseling of oldest-old women around mammography screening. Qualitative research using in-depth semi-structured interviews. Twenty-three women aged 80 or older who received care at a large academic primary care practice (13 had undergone mammography screening in the past 2 years) and 16 physicians at the same center. We asked patients and physicians to describe factors influencing mammography screening decisions of oldest-old women. We asked physicians to describe their counseling about screening to the oldest-old. Patients and/or physicians identified the importance of physician influence, patient preferences, system factors, and social influences on screening decisions. Although physicians felt that patient's health affected screening decisions, few patients felt that health mattered. Three types of elderly patients were identified: (1) women enthusiastic about screening mammography; (2) women opposed to screening mammography; and (3) women without a preference who followed their physician's recommendation. However, physician counseling about mammography screening to elderly women varies; some individualize discussions; others encourage screening; few discourage screening. Physicians report that discussions about stopping screening can be uncomfortable and time consuming. Physicians suggest that more data could facilitate these discussions. Some oldest-old women have strong opinions about screening mammography while others are influenced by physicians. Discussions about stopping screening are challenging for physicians. More data about the benefits and risks of mammography screening for women aged 80 or older could inform patients and improve provider counseling to lead to more rational use of mammography.
MRI breast screening in high-risk women: cancer detection and survival analysis.
Evans, D Gareth; Gareth, Evans D; Kesavan, Nisha; Nisha, Kesavan; Lim, Yit; Yit, Lim; Gadde, Soujanye; Soujanye, Gadde; Hurley, Emma; Emma, Hurley; Massat, Nathalie J; Maxwell, Anthony J; Ingham, Sarah; Sarah, Ingham; Eeles, Rosalind; Rosalind, Eeles; Leach, Martin O; Howell, Anthony; Anthony, Howell; Duffy, Stephen W; Stephen, Duffy
2014-06-01
Women with a genetic predisposition to breast cancer tend to develop the disease at a younger age with denser breasts making mammography screening less effective. The introduction of magnetic resonance imaging (MRI) for familial breast cancer screening programs in recent years was intended to improve outcomes in these women. We aimed to assess whether introduction of MRI surveillance improves 5- and 10-year survival of high-risk women and determine the accuracy of MRI breast cancer detection compared with mammography-only or no enhanced surveillance and compare size and pathology of cancers detected in women screened with MRI + mammography and mammography only. We used data from two prospective studies where asymptomatic women with a very high breast cancer risk were screened by either mammography alone or with MRI also compared with BRCA1/2 carriers with no intensive surveillance. 63 cancers were detected in women receiving MRI + mammography and 76 in women receiving mammography only. Sensitivity of MRI + mammography was 93 % with 63 % specificity. Fewer cancers detected on MRI were lymph node positive compared to mammography/no additional screening. There were no differences in 10-year survival between the MRI + mammography and mammography-only groups, but survival was significantly higher in the MRI-screened group (95.3 %) compared to no intensive screening (73.7 %; p = 0.002). There were no deaths among the 21 BRCA2 carriers receiving MRI. There appears to be benefit from screening with MRI, particularly in BRCA2 carriers. Extended follow-up of larger numbers of high-risk women is required to assess long-term survival.
Effects of digital mammography uptake on downstream breast-related care among older women.
Hubbard, Rebecca A; Zhu, Weiwei; Onega, Tracy L; Fishman, Paul; Henderson, Louise M; Tosteson, Anna N A; Buist, Diana S M
2012-12-01
Digital mammography is the dominant modality for breast cancer screening in the United States. No previous studies have investigated as to how introducing digital mammography affects downstream breast-related care. Compare breast-related health care use after a screening mammogram before and after introduction of digital mammography. Longitudinal study of screening mammograms from 14 radiology facilities contributing data to the Breast Cancer Surveillance Consortium performed 1 year before and 4 years after each facility introduced digital mammography, along with linked Medicare claims. We included 30,211 mammograms for women aged 66 years and older without breast cancer. Rates of false-positive recall and short-interval follow-up were based on radiologists' assessments and recommendations; rates of follow-up mammography, ultrasound, and breast biopsy use were based on Medicare claims. False-positive recall rates increased after the introduction of digital mammography. Follow-up mammography use was significantly higher across all 4 years after a facility began using digital mammography compared with the year before [year 1 odds ratio (OR) = 1.7, 95% confidence interval (CI), 1.4-2.1]. Among women with false-positive mammography results, use of ultrasound decreased significantly in the second through fourth years after digital mammography began (year 2 OR = 0.4, 95% CI, 0.3-0.6). Introduction of a new technology led to changes in health care use that persisted for at least 4 years. Comparative effectiveness research on new technologies should consider not only diagnostic performance but also downstream utilization attributable to this apparent learning curve.
Sadigh, Gelareh; Singh, Kush; Gilbert, Kirven; Khan, Ramsha; Duszak, Abigail M; Duszak, Richard
2016-11-01
Ongoing controversy regarding screening mammography guidelines has created confusion for many patients. Given recommendations that patient educational material be prepared at or below the 7th grade reading level of average Americans, the purpose of this study was to assess the readability of online mammography information offered by hospitals nationwide. During 2015, online mammography patient educational materials were identified for all Medicare-recognized hospitals nationwide for which screening mammography metrics were publicly available. Patient educational materials were assessed using six validated readability score algorithms. All references to official screening guidelines were captured. Of 4105 hospitals nationwide, 3252 had websites and confirmable screening mammography services. Of those, 1753 (54%) offered mammography information material online. Only 919 (28%) referenced any professional society guidelines. After excluding information not formatted in HTML and shorter than 100 words (to improve algorithm reliability), 1524 hospital mammography webpages were assessed for grade level scores. Nationally, the mean of each readability score for all hospitals varied between the 10th and 14th grade levels, all higher than the recommended 7th grade level (p < 0.001). At the individual hospital level, only 14 hospitals (0.4%) had mean scores at or below the 7th grade level. Of U.S. hospitals that offer screening mammography and have websites, only 54% provide online mammography educational material. Of those, only 0.4% present information at a reading level comprehensible to average Americans, and only 28% offer specific information to help patients reconcile conflicting guidelines. Health systems offering mammography should strive to better meet women's health information and literacy needs.
Skinner, Celette Sugg; Kobrin, Sarah C; Monahan, Patrick O; Daggy, Joanne; Menon, Usha; Todora, Helen Smith; Champion, Victoria L
2007-01-01
To assess added value of a booster dose of a tailored mammography intervention. Participants, non-adherent at baseline, were randomly assigned to usual care or one of three tailored interventions. Intervention group members (n=657) were further randomly assigned to receive/not receive a booster intervention dose. Electronic record mammography data were collected following initial intervention and at 6 and 15 months post-booster. Booster had no effect among women not screened after first intervention dose (n=337). Among women screened after initial dose (n=320), booster predicted re-screening at 6 but not 15 months. A boosterxrace interaction showed a booster effect at 6 months for African Americans (OR=4.66, p=.0005) but not Caucasians (OR=0.74, p=.44). Findings suggest if a first-dose intervention does not facilitate screening, neither will a booster dose. However, among women for whom a first dose is effective, boosters can facilitate timely repeat adherence, especially among African Americans. At 6 months booster recipients were less likely to be off-schedule but, by 15 months, the groups were similar. Boosters may effect when, but not whether, women continue screening.
Gamma-ray detectors for breast imaging
NASA Astrophysics Data System (ADS)
Williams, Mark B.; Goode, Allen R.; Majewski, Stan; Steinbach, Daniela; Weisenberger, Andrew G.; Wojcik, Randolph F.; Farzanpay, Farzin
1997-07-01
Breast cancer is the most common cancer of American women and is the leading cause of cancer-related death among women aged 15 - 54; however recent years have shown that early detection using x-ray mammography can lead to a high probability of cure. However, because of mammography's low positive predictive value, surgical or core biopsy is typically required for diagnosis. In addition, the low radiographic contrast of many nonpalpable breast masses, particularly among women with radiographically dense breasts, results in an overall rate of 10% to 25% for missed tumors. Nuclear imaging of the breast using single gamma emitters (scintimammography) such as (superscript 99m)Tc, or positron emitters such as F-18- fluorodeoxyglucose (FDG) for positron emission tomography (PET), can provide information on functional or metabolic tumor activity that is complementary to the structural information of x-ray mammography, thereby potentially reducing the number of unnecessary biopsies and missed cancers. This paper summarizes recent data on the efficacy of scintimammography using conventional gamma cameras, and describes the development of dedicated detectors for gamma emission breast imaging. The detectors use new, high density crystal scintillators and large area position sensitive photomultiplier tubes (PSPMTs). Detector design, imaging requirements, and preliminary measured imaging performance are discussed.
[Exploring a non-inflammatory clinical breast mass: Clinical practice guidelines].
Legendre, G; Guilhen, N; Nadeau, C; Brossard, A; Fauvet, R
2015-12-01
The aim of the study was to assess the diagnostic value of physical examination, radiologic explorations and percutaneous procedures of the breast in the exploration of a non-inflammatory palpable mass, in order to propose guidelines. A systematic literature review was conducted in the Medline and Cochrane library databases. International guidelines in French and English language were also consulted until April 30th 2015. Physical examination of a non-inflammatory palpable breast mass is not sufficient to eliminate a breast cancer (LE2). Mammography alone has a sensitivity between 70 and 95% for the diagnosis of breast cancer (LE3). Echography alone has a sensitivity of 98 to 100% for the diagnosis of breast cancer (LE2). The core needle biopsy has a better sensitivity and specificity than the fine-needle aspiration for breast cancer diagnosis (LE2). The association of mammography and 2D echography presents excellent sensitivity and negative predictive value (close to 100 %) to exclude a breast cancer (LE3). A double evaluation using mammography and echography is recommended in the exploration of a non-inflammatory palpable breast mass (grade B). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
van Zelst, Jan C M; Mus, Roel D M; Woldringh, Gwendolyn; Rutten, Matthieu J C M; Bult, Peter; Vreemann, Suzan; de Jong, Mathijn; Karssemeijer, Nico; Hoogerbrugge, Nicoline; Mann, Ritse M
2017-11-01
Purpose To evaluate a multimodal surveillance regimen including yearly full-field digital (FFD) mammography, dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging, and biannual automated breast (AB) ultrasonography (US) in women with BRCA1 and BRCA2 mutations. Materials and Methods This prospective multicenter trial enrolled 296 carriers of the BRCA mutation (153 BRCA1 and 128 BRCA2 carriers, and 15 women with first-degree untested relatives) between September 2010 and November 2012, with follow-up until November 2015. Participants underwent 2 years of intensified surveillance including biannual AB US, and routine yearly DCE MR imaging and FFD mammography. The surveillance performance for each modality and possible combinations were determined. Results Breast cancer was screening-detected in 16 women (age range, 33-58 years). Three interval cancers were detected by self-examination, all in carriers of the BRCA1 mutation under age 43 years. One cancer was detected in a carrier of the BRCA1 mutation with a palpable abnormality in the contralateral breast. One incidental breast cancer was detected in a prophylactic mastectomy specimen. Respectively, sensitivity of DCE MR imaging, FFD mammography, and AB US was 68.1% (14 of 21; 95% confidence interval [CI]: 42.9%, 85.8%), 37.2% (eight of 21; 95% CI: 19.8%, 58.7%), and 32.1% (seven of 21; 95% CI: 16.1%, 53.8%); specificity was 95.0% (643 of 682; 95% CI: 92.7%, 96.5%), 98.1% (638 of 652; 95% CI: 96.7%, 98.9%), and 95.1% (1030 of 1088; 95% CI: 93.5%, 96.3%); cancer detection rate was 2.0% (14 of 702), 1.2% (eight of 671), and 1.0% (seven of 711) per 100 women-years; and positive predictive value was 25.2% (14 of 54), 33.7% (nine of 23), and 9.5% (seven of 68). DCE MR imaging and FFD mammography combined yielded the highest sensitivity of 76.3% (16 of 21; 95% CI: 53.8%, 89.9%) and specificity of 93.6% (643 of 691; 95% CI: 91.3%, 95.3%). AB US did not depict additional cancers. FFD mammography yielded no additional cancers in women younger than 43 years, the mean age at diagnosis. In carriers of the BRCA2 mutation, sensitivity of FFD mammography with DCE MR imaging surveillance was 90.9% (10 of 11; 95% CI: 72.7%, 100%) and 60.0% (six of 10; 95% CI: 30.0%, 90.0%) in carriers of the BRCA1 mutation because of the high interval cancer rate in carriers of the BRCA1 mutation. Conclusion AB US may not be of added value to yearly FFD mammography and DCE MR imaging surveillance of carriers of the BRCA mutation. Study results suggest that carriers of the BRCA mutation younger than 40 years may not benefit from FFD mammography surveillance in addition to DCE MR imaging. © RSNA, 2017 Online supplemental material is available for this article.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329
Advanced Breast Cancer as Indicator of Quality Mammography
NASA Astrophysics Data System (ADS)
Gaona, Enrique
2003-09-01
Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is the more important screening tool for detecting early breast cancer. Screening mammography involves taking x-rays from two views from each breast, typically from above (cranial-caudal view, CC) and from an oblique or angled view (mediolateral-oblique, MLO). The purpose of this study was to carry out an exploratory survey of the issue of patients with advanced breast cancer who have had a screening mammography. A general result of the survey is that 22.5% of all patients (102) with advanced breast cancer that participated in the study had previous screening mammography. But we should consider that 10% of breast cancers are not detected by mammography. Only 70% of the family doctors prescribed a diagnostic mammography when the first symptoms were diagnosed.
ERIC Educational Resources Information Center
Slater, Jonathan S.; Parks, Michael J.; Malone, Michael E.; Henly, George A.; Nelson, Christina L.
2017-01-01
Financial incentives are being used increasingly to encourage a wide array of health behaviors because of their well-established efficacy. However, little is known about how to translate incentive-based strategies to public health practice geared toward improving population-level health, and a dearth of research exists on how individuals respond…
The mammography screening employee inreach program.
Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria
2007-02-01
To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.
NASA Astrophysics Data System (ADS)
Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury
2017-09-01
The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.
Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia
2017-06-01
This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.
Carmona-Torres, Juan Manuel; Cobo-Cuenca, Ana Isabel; Martín-Espinosa, Noelia María; Piriz-Campos, Rosa María; Laredo-Aguilera, José Alberto; Rodríguez-Borrego, María Aurora
2018-04-01
To determine the frequency of the performance of mammography with preventive purpose of the screening of breast cancer in Spanish women, the evolution between the years 2006-2014, the sociodemographic profile of the women who undergo the mammography and to analyze the factors that influence in their adhesion. Transversal study. Spain. A total of 53.628 women over 15 years old that are surveyed in the National Health Survey in Spain 2006 and 2011/12 and the European Health Survey in Spain 2009 and 2014. The following variables were used: mammography, frequency of mammography performance and the reason for the realization, as well as sociodemographic variables. Social class was obtained from the last occupation of the main family supporter. A logistic regression analysis was performed with sociodemographic variables. The prevalence of mammography has been increasing from 2006 to 2014, and also for the reason that the participants had received a letter, they were telephoned or offered in their Health Center to undergo this test. There are significant differences in the performance of mammography in the different autonomous communities. Performing mammography has increased significantly from 2006 to 2014, although there are still differences between autonomous communities, with Ceuta and Melilla being the least percentage of performed mammography. The factors that are related to greater performed mammography are: higher educational level, higher social class, married civil status, Spanish nationality and age. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Wujcik, Debra; Lin, Jin-Mann S.; Grau, Ana; Wilson, Veronica; Champion, Victoria; Zheng, Wei; Egan, Kathleen M.
2009-01-01
Abstract Background The relationship between obesity and screening mammography adherence has been examined previously, yet few studies have investigated obesity as a potential mediator of timely follow-up of abnormal (Breast Imaging Reporting and Data System [BIRADS-0]) mammography results in minority and medically underserved patients. Methods We conducted a retrospective cohort study of 35 women who did not return for follow-up >6 months from index abnormal mammography and 41 who returned for follow-up ≤6 months in Nashville, Tennessee. Patients with a BIRADS-0 mammography event in 2003–2004 were identified by chart review. Breast cancer risk factors were collected by telephone interview. Multivariate logistic regression was performed on selected factors with return for diagnostic follow-up. Results Obesity and gynecological history were significant predictors of abnormal mammography resolution. A significantly higher frequency of obese women delayed return for mammography resolution compared with nonobese women (64.7% vs. 35.3%). A greater number of hysterectomized women returned for diagnostic follow-up compared with their counterparts without a hysterectomy (77.8% vs. 22.2%). Obese patients were more likely to delay follow-up >6 months (adjusted OR 4.09, p = 0.02). Conversely, hysterectomized women were significantly more likely to return for timely mammography follow-up ≤6 months (adjusted OR 7.95, p = 0.007). Conclusions Study results suggest that weight status and gynecological history influence patients' decisions to participate in mammography follow-up studies. Strategies are necessary to reduce weight-related barriers to mammography follow-up in the healthcare system including provider training related to mammography screening of obese women. PMID:19558307
D'Orsi, Carl; Tu, Shin-Ping; Nakano, Connie; Carney, Patricia A.; Abraham, Linn A.; Taplin, Stephen H.; Hendrick, R. Edward; Cutter, Gary R.; Berns, Eric; Barlow, William E.; Elmore, Joann G.
2011-01-01
PURPOSE To evaluate the current (2001–2002) capacity of community-based mammography facilities to deliver screening and diagnostic services in the United States. MATERIALS AND METHODS Institutional review board approvals and patient consent were obtained. A mailed survey was sent to 53 eligible mammography facilities in three states (Washington, New Hampshire, and Colorado). Survey questions assessed equipment and staffing availability, as well as appointment waiting times for screening and diagnostic mammography services. Criterion-related content and construct validity were obtained first by means of a national advisory committee of academic, scientific, and clinical colleagues in mammography that reviewed literature on existing surveys and second by pilot testing a series of draft surveys among community mammography facilities not inclusive of the study facilities. The final survey results were independently double entered into a relational database with programmed data checks. The data were sent encrypted by means of file transfer protocol to a central analytical center at Group Health Cooperative. A two-sided P value with α = .05 was considered to show statistical significance in all analyses. RESULTS Forty-five of 53 eligible mammography facilities (85%) returned the survey. Shortages of radiologists relative to the mammographic volume were found in 44% of mammography facilities overall, with shortages of radiologists higher in not-for-profit versus for-profit facilities (60% vs 28% reported). Shortages of Mammography Quality Standards Act–qualified technologists were reported by 20% of facilities, with 46% reporting some level of difficulty in maintaining qualified technologists. Waiting times for diagnostic mammography ranged from less than 1 week to 4 weeks, with 85% performed within 1 week. Waiting times for screening mammography ranged from less than 1 week to 8 weeks, with 59% performed between 1 week and 4 weeks. Waiting times for both diagnostic and screening services were two to three times higher in high-volume compared with low-volume facilities. CONCLUSION Survey results show shortages of radiologists and certified mammography technologists. PMID:15798153
Dershaw, D. David; Sung, Janice S.; Heerdt, Alexandra S.; Thornton, Cynthia; Moskowitz, Chaya S.; Ferrara, Jessica; Morris, Elizabeth A.
2013-01-01
Purpose To determine feasibility of performing bilateral dual-energy (DE) contrast agent–enhanced (CE) digital mammography and to evaluate its performance compared with conventional digital mammography and breast magnetic resonance (MR) imaging in women with known breast cancer. Materials and Methods This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained. Patient accrual began in March 2010 and ended in August 2011. Mean patient age was 49.6 years (range, 25–74 years). Feasibility was evaluated in 10 women with newly diagnosed breast cancer who were injected with 1.5 mL per kilogram of body weight of iohexol and imaged between 2.5 and 10 minutes after injection. Once feasibility was confirmed, 52 women with newly diagnosed cancer who had undergone breast MR imaging gave consent to undergo DE CE digital mammography. Positive findings were confirmed with pathologic findings. Results Feasibility was confirmed with no adverse events. Visualization of tumor enhancement was independent of timing after contrast agent injection for up to 10 minutes. MR imaging and DE CE digital mammography both depicted 50 (96%) of 52 index tumors; conventional mammography depicted 42 (81%). Lesions depicted by using DE CE digital mammography ranged from 4 to 67 mm in size (median, 17 mm). DE CE digital mammography depicted 14 (56%) of 25 additional ipsilateral cancers compared with 22 (88%) of 25 for MR imaging. There were two false-positive findings with DE CE digital mammography and 13 false-positive findings with MR imaging. There was one contralateral cancer, which was not evident with either modality. Conclusion Bilateral DE CE digital mammography was feasible and easily accomplished. It was used to detect known primary tumors at a rate comparable to that of MR imaging and higher than that of conventional digital mammography. DE CE digital mammography had a lower sensitivity for detecting additional ipsilateral cancers than did MR imaging, but the specificity was higher. © RSNA, 2012 PMID:23220903
Kerlikowske, Karla; Hubbard, Rebecca A.; Miglioretti, Diana L.; Geller, Berta M.; Yankaskas, Bonnie C.; Lehman, Constance D.; Taplin, Stephen H.; Sickles, Edward A.
2013-01-01
Background Few studies have examined the comparative effectiveness of digital versus film-screen mammography in U.S. community practice. Objective To determine whether the interpretive performance of digital and film-screen mammography differs. Design Prospective cohort study. Setting Mammography facilities in the Breast Cancer Surveillance Consortium. Participants 329 261 women aged 40 to 79 years underwent 869 286 mammograms (231 034 digital; 638 252 film-screen). Measurements Invasive cancer or ductal carcinoma in situ diagnosed within 12 months of a digital or film-screen examination and calculation of mammography sensitivity, specificity, cancer detection rates, and tumor outcomes. Results Overall, cancer detection rates and tumor characteristics were similar for digital and film-screen mammography, but the sensitivity and specificity of each modality varied by age, tumor characteristics, breast density, and menopausal status. Compared with film-screen mammography, the sensitivity of digital mammography was significantly higher for women aged 60 to 69 years (89.9% vs. 83.0%; P = 0.014) and those with estrogen receptor-negative cancer (78.5% vs. 65.8%; P = 0.016); borderline significantly higher for women aged 40 to 49 years (82.4% vs. 75.6%; P = 0.071), those with extremely dense breasts (83.6% vs. 68.1%; P= 0.051), and pre- or perimenopausal women (87.1% vs. 81.7%; P = 0.057); and borderline significantly lower for women aged 50 to 59 years (80.5% vs. 85.1%; P = 0.097). The specificity of digital and film-screen mammography was similar by decade of age, except for women aged 40 to 49 years (88.0% vs. 89.7%; P< 0.001). Limitation Statistical power for subgroup analyses was limited. Conclusion Overall, cancer detection with digital or film-screen mammography is similar in U.S. women aged 50 to 79 years undergoing screening mammography. Women aged 40 to 49 years are more likely to have extremely dense breasts and estrogen receptor-negative tumors; if they are offered mammography screening, they may choose to undergo digital mammography to optimize cancer detection. Primary Funding Source National Cancer Institute. PMID:22007043
Kerlikowske, K; Salzmann, P; Phillips, K A; Cauley, J A; Cummings, S R
1999-12-08
Mammography is recommended and is cost-effective for women aged 50 to 69 years, but the value of continuing screening mammography after age 69 years is not known. In particular, older women with low bone mineral density (BMD) have a lower risk of breast cancer and may benefit less from continued screening. To compare life expectancy and cost-effectiveness of screening mammography in elderly women based on 3 screening strategies. Decision analysis and cost-effectiveness analysis using a Markov model. General population of women aged 65 years or older. The analysis compared 3 strategies: (1) Undergoing biennial mammography from age 65 to 69 years; (2) undergoing biennial mammography from age 65 to 69 years, measurement of distal radial BMD at age 65 years, discontinuing screening at age 69 years in women in the lowest BMD quartile for age, and continuing biennial mammography to age 79 years in those in the top 3 quartiles of distal radius BMD; and (3) undergoing biennial mammography from age 65 to 79 years. Deaths due to breast cancer averted, life expectancy, and incremental cost-effectiveness ratios. Compared with discontinuing mammography screening at age 69 years, measuring BMD at age 65 years in 10000 women and continuing mammography to age 79 years only in women with BMD in the top 3 quartiles would prevent 9.4 deaths and add, on average, 2.1 days to life expectancy at an incremental cost of $66773 per year of life saved. Continuing mammography to age 79 years in all 10000 elderly women would prevent 1.4 additional breast cancer deaths and add only 7.2 hours to life expectancy at an incremental cost of $117689 per year of life saved compared with only continuing mammography to age 79 years in women with BMD in the top 3 quartiles. This analysis suggests that continuing mammography screening after age 69 years results in a small gain in life expectancy and is moderately cost-effective in those with high BMD and more costly in those with low BMD. Women's preferences for a small gain in life expectancy and the potential harms of screening mammography should play an important role when elderly women are deciding about screening.
From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale
ERIC Educational Resources Information Center
Thomas, Eileen
2011-01-01
The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…
Do cultural factors predict mammography behaviour among Korean immigrants in the USA?
Lee, Hanju; Kim, Jiyun; Han, Hae-Ra
2009-12-01
This paper is a report of a study of the correlates of mammogram use among Korean American women. Despite the increasing incidence of and mortality from breast cancer, Asian women in the United States of America report consistently low rates of mammography screening. A number of health beliefs and sociodemographic characteristics have been associated with mammogram participation among these women. However, studies systematically investigating cultural factors in relation to mammogram experience have been scarce. We measured screening-related health beliefs, modesty and use of Eastern medicine in 100 Korean American women in 2006. Hierarchical logistic regression was used to examine the unique contribution of the study variables, after accounting for sociodemographic characteristics. Only 51% reported past mammogram use. Korean American women who had previously had mammograms were statistically significantly older and had higher perceived benefit scores than those who had not. Perceived benefits (odds ratio = 6.3, 95% confidence interval = 2.12, 18.76) and breast cancer susceptibility (odds ratio = 3.18, 95% confidence interval = 1.06, 9.59) were statistically significant correlates of mammography experience, whereas cultural factors did not correlate. Post hoc analysis showed that for women with some or good English skills, cultural factors statistically significantly correlated with health beliefs and breast cancer knowledge (P < 0.05). Nurses should consider the inclusion in culturally tailored interventions of more targeted outreach and healthcare system navigation assistance for promoting mammography screening in Korean American women. Further research is needed to unravel the interplay between acculturation, cultural factors and health beliefs related to cancer screening behaviours of Korean American women.
Mandelblatt, J; Traxler, M; Lakin, P; Kanetsky, P; Kao, R
1993-01-01
Factors associated with participation in breast and cervix cancer screening among elderly black women of low socioeconomic status were determined. Data from a baseline cross-sectional random survey were used together with data on whether screening was subsequently completed or refused. The subjects were a random sample of women attending an urban public hospital primary care clinic for routine medical care with a birth year of 1924 or earlier. Among the 271 women in the study group, 70% completed screening. Stated intent was the strongest predictor of participation; women who intended to have both mammography and Pap testing were 2.7 times more likely to participate than those who intended to have neither test (95% confidence interval 1.4, 4.9; P < 0.01), controlling for age, insurance status, and level of chronic illness. Women who had more than three chronic illnesses were twice as likely to participate than those with three or fewer illnesses (95% confidence interval 1.1, 3.4 P < 0.02), controlling for the remaining variables. Other variables, including age, history of a recent screening examination, attitudes, or knowledge, were not related to participation. Stated intent was the only variable that predicted compliance with both mammography and Pap smear completion in separate regression models for the individual tests. A high proportion of elderly, socioeconomically disadvantaged black women will participate in cancer screening when it is offered in a primary care setting. Further research on behavioral intentions should be conducted to refine interventions designed to enhance the use of early cancer detection among vulnerable population groups.
Mammography; Breast cancer - mammography; Breast cancer - screening mammography; Breast lump - mammogram; Breast tomosynthesis ... images. This does not always mean you have breast cancer. Your health care provider may simply need to ...
ERIC Educational Resources Information Center
Kung, Pei-Tseng; Tsai, Wen-Chen; Chiou, Shang-Jyh
2012-01-01
Research that identifies the determinants of low mammography use among disabled people is scant. This study examines the determining factors related to the low usage of mammography among women with disabilities. To identify the barriers that prevent women with disabilities from participating in mammography screening can help authorities conceive…
ERIC Educational Resources Information Center
Molina, Yamile; Ornelas, India J.; Doty, Sarah L.; Bishop, Sonia; Beresford, Shirley A. A.; Coronado, Gloria D.
2015-01-01
Identifying factors that increase mammography use among Latinas is an important public health priority. Latinas are more likely to report mammography intentions and use, if a family member or friend recommends that they get a mammogram. Little is known about the mechanisms underlying the relationship between social interactions and mammography…
Quality assurance and ergonomics in the mammography department.
Reynolds, April
2014-01-01
Quality assurance (QA) in mammography is a system of checks that helps ensure the proper functioning of imaging equipment and processes. Ergonomics is a scientific approach to arranging the work environment to reduce the risk of work-related injuries while increasing staff productivity and job satisfaction. This article reviews both QA and ergonomics in mammography and explains how they work together to create a safe and healthy environment for radiologic technologists and their patients. QA and quality control requirements in mammography are discussed, along with ergonomic best practices in the mammography setting.
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, Joshua J.; Taplin, Stephen H.; Carney, Patricia A.; Abraham, Linn; Sickles, Edward A.; D'Orsi, Carl; Berns, Eric A.; Cutter, Gary; Hendrick, R. Edward; Barlow, William E.; Elmore, Joann G.
2011-01-01
Background Computer-aided detection identifies suspicious findings on mammograms to assist radiologists. Since the Food and Drug Administration approved the technology in 1998, it has been disseminated into practice, but its effect on the accuracy of interpretation is unclear. Methods We determined the association between the use of computer-aided detection at mammography facilities and the performance of screening mammography from 1998 through 2002 at 43 facilities in three states. We had complete data for 222,135 women (a total of 429,345 mammograms), including 2351 women who received a diagnosis of breast cancer within 1 year after screening. We calculated the specificity, sensitivity, and positive predictive value of screening mammography with and without computer-aided detection, as well as the rates of biopsy and breast-cancer detection and the overall accuracy, measured as the area under the receiver-operating-characteristic (ROC) curve. Results Seven facilities (16%) implemented computer-aided detection during the study period. Diagnostic specificity decreased from 90.2% before implementation to 87.2% after implementation (P<0.001), the positive predictive value decreased from 4.1% to 3.2% (P = 0.01), and the rate of biopsy increased by 19.7% (P<0.001). The increase in sensitivity from 80.4% before implementation of computer-aided detection to 84.0% after implementation was not significant (P = 0.32). The change in the cancer-detection rate (including invasive breast cancers and ductal carcinomas in situ) was not significant (4.15 cases per 1000 screening mammograms before implementation and 4.20 cases after implementation, P = 0.90). Analyses of data from all 43 facilities showed that the use of computer-aided detection was associated with significantly lower overall accuracy than was nonuse (area under the ROC curve, 0.871 vs. 0.919; P = 0.005). Conclusions The use of computer-aided detection is associated with reduced accuracy of interpretation of screening mammograms. The increased rate of biopsy with the use of computer-aided detection is not clearly associated with improved detection of invasive breast cancer. PMID:17409321
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84-12.82). DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers.
Cost-effectiveness of strategies to enhance mammography use.
Fishman, P; Taplin, S; Meyer, D; Barlow, W
2000-01-01
To estimate the cost-effectiveness of three strategies to increase breast cancer screening with mammography (reminder postcard, reminder telephone call, and motivational telephone call). Cost accounting for each strategy followed by cost-effectiveness analysis. DATA SOURCE FOR EFFECTIVENESS: Randomized trial of three strategies conducted at Group Health Cooperative of Puget Sound (GHC). Women 50 to 79 years of age who were enrolled in GHC's breast cancer screening program who did not schedule screening mammography within 2 months after it was recommended by letter. Health plan. Marginal cost-effectiveness of each additional woman screened. Because of its high cost (about $26 per call) and intermediate effectiveness, the motivational call was the least cost-effective strategy. If it was assumed that 50% of the women who scheduled mammography after receiving the reminder postcard would have scheduled mammography within 10 months even without it, marginal cost-effectiveness for the postcard among all women was $22 per woman screened versus $92 for the reminder call. Among women with no previous mammography, the marginal cost-effectiveness for the postcard was $70 versus $100 for the reminder call. Among women with no previous mammography, the choice between the reminder postcard and the reminder call was sensitive to assumptions about the percentage of women expected to receive mammography in the absence of other promotional strategies. A simple reminder postcard is the most cost-effective way to increase mammography. Choices about how to promote mammography will ultimately depend on plan values and willingness to invest in promotional strategies that increase participation at higher unit costs.
The role of cone-beam breast-CT for breast cancer detection relative to breast density.
Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe
2017-12-01
To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (p<0.001). • Specificity was higher for mammography than CBBCT in both density types (p<0.05). • AUC was larger for mammography than CBBCT in both density types (p<0.001).
Mammographic density is the main correlate of tumors detected on ultrasound but not on mammography.
Häberle, Lothar; Fasching, Peter A; Brehm, Barbara; Heusinger, Katharina; Jud, Sebastian M; Loehberg, Christian R; Hack, Carolin C; Preuss, Caroline; Lux, Michael P; Hartmann, Arndt; Vachon, Celine M; Meier-Meitinger, Martina; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger
2016-11-01
Although mammography screening programs do not include ultrasound examinations, some diagnostic units do provide women with both mammography and ultrasonography. This article is concerned with estimating the risk of a breast cancer patient diagnosed in a hospital-based mammography unit having a tumor that is visible on ultrasound but not on mammography. A total of 1,399 women with invasive breast cancer from a hospital-based diagnostic mammography unit were included in this retrospective study. For inclusion, mammograms from the time of the primary diagnosis had to be available for computer-assisted assessment of percentage mammographic density (PMD), as well as Breast Imaging Reporting and Data System (BIRADS) assessment of mammography. In addition, ultrasound findings were available for the complete cohort as part of routine diagnostic procedures, regardless of any patient or imaging characteristics. Logistic regression analyses were conducted to identify predictors of mammography failure, defined as BIRADS assessment 1 or 2. The probability that the visibility of a tumor might be masked at diagnosis was estimated using a regression model with the identified predictors. Tumors were only visible on ultrasound in 107 cases (7.6%). PMD was the strongest predictor for mammography failure, but age, body mass index and previous breast surgery also influenced the risk, independently of the PMD. Risk probabilities ranged from 1% for a defined low-risk group up to 40% for a high-risk group. These findings might help identify women who should be offered ultrasound examinations in addition to mammography. © 2016 UICC.
Automated daily quality control analysis for mammography in a multi-unit imaging center.
Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli
2018-01-01
Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.
Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine MA; van den Heuvel, Edwin R; Houssami, Nehmat
2016-01-01
Background: We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Methods: Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. Results: In BRCA1/2 mutation carriers of all ages (BRCA1=1219 and BRCA2=732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P>0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Conclusions: Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering. PMID:26908327
Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine M A; van den Heuvel, Edwin R; Houssami, Nehmat
2016-03-15
We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. In BRCA1/2 mutation carriers of all ages (BRCA1 = 1,219 and BRCA2 = 732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P > 0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽ 40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering.
Applying a new mammographic imaging marker to predict breast cancer risk
NASA Astrophysics Data System (ADS)
Aghaei, Faranak; Danala, Gopichandh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin
2018-02-01
Identifying and developing new mammographic imaging markers to assist prediction of breast cancer risk has been attracting extensive research interest recently. Although mammographic density is considered an important breast cancer risk, its discriminatory power is lower for predicting short-term breast cancer risk, which is a prerequisite to establish a more effective personalized breast cancer screening paradigm. In this study, we presented a new interactive computer-aided detection (CAD) scheme to generate a new quantitative mammographic imaging marker based on the bilateral mammographic tissue density asymmetry to predict risk of cancer detection in the next subsequent mammography screening. An image database involving 1,397 women was retrospectively assembled and tested. Each woman had two digital mammography screenings namely, the "current" and "prior" screenings with a time interval from 365 to 600 days. All "prior" images were originally interpreted negative. In "current" screenings, these cases were divided into 3 groups, which include 402 positive, 643 negative, and 352 biopsy-proved benign cases, respectively. There is no significant difference of BIRADS based mammographic density ratings between 3 case groups (p < 0.6). When applying the CAD-generated imaging marker or risk model to classify between 402 positive and 643 negative cases using "prior" negative mammograms, the area under a ROC curve is 0.70+/-0.02 and the adjusted odds ratios show an increasing trend from 1.0 to 8.13 to predict the risk of cancer detection in the "current" screening. Study demonstrated that this new imaging marker had potential to yield significantly higher discriminatory power to predict short-term breast cancer risk.
Promoting mammography screening among Chinese American women using a message-framing intervention.
Sun, Yiyuan; Sarma, Elizabeth A; Moyer, Anne; Messina, Catherine R
2015-07-01
This study examined the role of women's perceptions about the relative pros versus cons (decisional balance) of mammography in moderating Chinese American women's responses to gain- and loss-framed messages that promote mammography. One hundred and forty-three Chinese American women who were currently nonadherent to guidelines for receiving annual screening mammograms were randomly assigned to read either a gain- or loss-framed culturally appropriate print brochure about mammography screening. Mammography screening was self-reported at a 2-month follow-up. Although there was not a main effect for message frame, the hypothesized interaction between message frame and decisional balance was significant, indicating that women who received a framed message that matched their decisional balance were significantly more likely to have obtained a mammogram by the follow-up than women who received a mismatched message. Results suggest that decisional balance, and more generally, perceptions about mammography, may be an important moderator of framing effects for mammography among Chinese American women. The match between message frame and decisional balance should be considered when attempting to encourage Chinese American women to receive mammography screening, as a match between the two may be most persuasive. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Wang, Judy H.; Liang, Wenchi; Schwartz, Marc D.; Lee, Marion M.; Kreling, Barbara; Mandelblatt, Jeanne S.
2008-01-01
This study developed and evaluated a culturally tailored video guided by the health belief model to improve Chinese women's low rate of mammography use. Focus-group discussions and an advisory board meeting guided the video development. A 17-min video, including a soap opera and physician-recommendation segment, was made in Chinese languages. A…
Intervention Approaches for Addressing Breast Cancer Disparities among African American Women
Coughlin, Steven S
2014-01-01
African American women in the U.S. have a higher mortality rate from breast cancer than white women. Black-white differences in survival persist even after accounting for disease stage and tumor characteristics suggesting that the higher rates of breast cancer mortality are due to social factors. Several factors may account for racial differences in breast cancer mortality including socioeconomic factors, access to screening mammography and timely treatment, and biological factors. Efforts to prevent deaths from breast cancer and to address breast cancer disparities have focused on early detection through routine mammography and timely referral for treatment. There is a need for culturally appropriate, tailored health messages for African American women to increase their knowledge and awareness of health behaviors for the early detection of breast cancer. Several promising intervention approaches are reviewed in this article including: 1) the use of cell phone text messaging and smart phone apps to increase breast cancer screening; 2) the use of radio stations that target African American audiences (“black radio”) for health promotion activities; and 3) church-based behavioral interventions to promote breast cancer screening among African American women. PMID:25568890
Dunn, Richard A; Tan, Andrew K G
2011-01-01
As is the case in many developing nations, previous studies of breast cancer screening behavior in Malaysia have used relatively small samples that are not nationally representative, thereby limiting the generalizability of results. Therefore, this study uses nationally representative data from the Malaysia Non-Communicable Disease Surveillance-1 to investigate the role of socio-economic status on breast cancer screening behavior in Malaysia, particularly differences in screening behaviour between ethnic groups. The decisions of 816 women above age 40 in Malaysia to screen for breast cancer using mammography, clinical breast exams (CBE), and breast self-exams (BSE) are modeled using logistic regression. Results indicate that after adjusting for differences in age, education, household income, marital status, and residential location, Malay women are less likely than Chinese and Indian women to utilize mammography, but more likely to perform BSE. Education level and urban residence are positively associated with utilization of each method, but these relationships vary across ethnicity. Higher education levels are strongly related to using each screening method among Chinese women, but have no statistically significant relationship to screening among Malays. © 2011 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jing, E-mail: jing.zhang2@duke.edu; Ghate, Sujata V.; Yoon, Sora C.
Purpose: Mammography is the most widely accepted and utilized screening modality for early breast cancer detection. Providing high quality mammography education to radiology trainees is essential, since excellent interpretation skills are needed to ensure the highest benefit of screening mammography for patients. The authors have previously proposed a computer-aided education system based on trainee models. Those models relate human-assessed image characteristics to trainee error. In this study, the authors propose to build trainee models that utilize features automatically extracted from images using computer vision algorithms to predict likelihood of missing each mass by the trainee. This computer vision-based approach tomore » trainee modeling will allow for automatically searching large databases of mammograms in order to identify challenging cases for each trainee. Methods: The authors’ algorithm for predicting the likelihood of missing a mass consists of three steps. First, a mammogram is segmented into air, pectoral muscle, fatty tissue, dense tissue, and mass using automated segmentation algorithms. Second, 43 features are extracted using computer vision algorithms for each abnormality identified by experts. Third, error-making models (classifiers) are applied to predict the likelihood of trainees missing the abnormality based on the extracted features. The models are developed individually for each trainee using his/her previous reading data. The authors evaluated the predictive performance of the proposed algorithm using data from a reader study in which 10 subjects (7 residents and 3 novices) and 3 experts read 100 mammographic cases. Receiver operating characteristic (ROC) methodology was applied for the evaluation. Results: The average area under the ROC curve (AUC) of the error-making models for the task of predicting which masses will be detected and which will be missed was 0.607 (95% CI,0.564-0.650). This value was statistically significantly different from 0.5 (p < 0.0001). For the 7 residents only, the AUC performance of the models was 0.590 (95% CI,0.537-0.642) and was also significantly higher than 0.5 (p = 0.0009). Therefore, generally the authors’ models were able to predict which masses were detected and which were missed better than chance. Conclusions: The authors proposed an algorithm that was able to predict which masses will be detected and which will be missed by each individual trainee. This confirms existence of error-making patterns in the detection of masses among radiology trainees. Furthermore, the proposed methodology will allow for the optimized selection of difficult cases for the trainees in an automatic and efficient manner.« less
TMIST is a randomized breast screening trial that compares two Food and Drug Administration (FDA)-approved types of digital mammography, standard digital mammography (2-D) with a newer technology called tomosynthesis mammography (3-D).
Yilmaz, Meryem; Sayin, Yazile Yazici
2014-07-01
To examine the translation and adaptation process from English to Turkish and the validity and reliability of the Champion's Health Belief Model Scales for Mammography Screening. Its aim (1) is to provide data about and (2) to assess Turkish women's attitudes and behaviours towards mammography. The proportion of women who have mammography is lower in Turkey. The Champion's Health Belief Model Scales for Mammography Screening-Turkish version can be helpful to determine Turkish women's health beliefs, particularly about mammography. Cross-sectional design was used to collect survey data from Turkish women: classical measurement method. The Champion's Health Belief Model Scales for Mammography Screening was translated from English to Turkish. Again, it was back translated into English. Later, the meaning and clarity of the scale items were evaluated by a bilingual group representing the culture of the target population. Finally, the tool was evaluated by two bilingual professional researchers in terms of content validity, translation validity and psychometric estimates of the validity and reliability. The analysis included a total of 209 Turkish women. The validity of the scale was confirmed by confirmatory factor analysis and criterion-related validity testing. The Champion's Health Belief Model Scales for Mammography Screening aligned to four factors that were coherent and relatively independent of each other. There was a statistically significant relationship among all of the subscale items: the positive and high correlation of the total item test score and high Cronbach's α. The scale has a strong stability over time: the Champion's Health Belief Model Scales for Mammography Screening demonstrated acceptable preliminary values of reliability and validity. The Champion's Health Belief Model Scales for Mammography Screening is both a reliable and valid instrument that can be useful in measuring the health beliefs of Turkish women. It can be used to provide data about healthcare practices required for mammography screening and breast cancer prevention. This scale will show nurses that nursing intervention planning is essential for increasing Turkish women's participation in mammography screening. © 2013 John Wiley & Sons Ltd.
Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.
2016-01-01
Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468
... Prior Mammograms Helps Radiologists Detect Breast Cancer MammographySavesLives.org A general information resource on breast imaging from ... doctors: Breast Density and Breast Cancer Screening RTAnswers.org Radiation Therapy for Breast Cancer MedLinePlus Mammography top ...
Adapting a Cancer Literacy Measure for Use Among Navajo Women.
Yost, Kathleen J; Bauer, Mark C; Buki, Lydia P; Austin-Garrison, Martha; Garcia, Linda V; Hughes, Christine A; Patten, Christi A
2017-05-01
The authors designed a community-based participatory research study to develop and test a family-based behavioral intervention to improve cancer literacy and promote mammography among Navajo women. Using data from focus groups and discussions with a community advisory committee, they adapted an existing questionnaire to assess cancer knowledge, barriers to mammography, and cancer beliefs for use among Navajo women. Questions measuring health literacy, numeracy, self-efficacy, cancer communication, and family support were also adapted. The resulting questionnaire was found to have good content validity, and to be culturally and linguistically appropriate for use among Navajo women. It is important to consider culture and not just language when adapting existing measures for use with AI/AN (American Indian/Alaskan Native) populations. English-language versions of existing literacy measures may not be culturally appropriate for AI/AN populations, which could lead to a lack of semantic, technical, idiomatic, and conceptual equivalence, resulting in misinterpretation of study outcomes.
Manjer, Åsa Ritenius; Emilsson, Ulla Melin; Zackrisson, Sophia
2015-06-28
Mammography screening can reduce breast cancer mortality. The aim of the present study was to investigate non-attendance in mammography screening in relation to different aspects of a women's social network, attitudes and cancer in close relations. Data from the Malmö Diet and Cancer Study baseline examination in 1991-1996 was used. A re-examination began in 2007, and 1452 women participated. Family composition, social support, sense of belonging, attitudes on screening and breast cancer risk and on previous cancer in close relations were investigated in relation to self-reported participation in mammography screening using logistic regression analysis, yielding odds ratios with 95 % confidence intervals. Both attendees (98.0 %) and non-attendees (95.2 %) considered mammography screening important. Non-attendance in mammography screening was associated with being unmarried vs. married (2.40:1.30-4.45) and with not having vs. having children (1.77:1.08-2.92). Non-attendees planned to abstain from mammography screening in the future more often than attendees (4.78:2.56-8.90), and they had often abstained from cervical cancer screening (1.69:1.04-2.75). No other statistically significant association was found. This study indicates that family composition, but not necessarily the presence or absence of social support, perceived cancer risk or cancer in close relations, may affect non-attendance in mammography screening. A positive attitude towards mammography screening was found among both attendees and non-attendees, although the latter group planned to a lesser degree to attend mammography screening in the future.
Beliefs of Turkish female teaching staff regarding mammography scanning.
Temel, Ayla Bayik; Ardahan, Melek; Sesli, Esra
2010-01-01
To our knowledge, there has hitherto been no research to determine the beliefs of female teaching staff, who are highly educated and form a special risk group regarding breast cancer, towards mammography scanning in Turkey. Definitive research was planned to determine the beliefs of the female teaching staff working in a university. Data were collected by researchers via face-to-face interview using a sociodemographic questionnaire and " Health Belief Model ". The point average of the teaching staff in the mammography benefits sub-scale is 19.6 ± 3.87, their average item score is 3.91. The point average of the teaching staff in the mammography obstacles sub-scale is 21.17 ± 6.87, their average item score is 1.92. They agree on the benefits of the mammography, but they do not agree on the obstacles to mammography.
Reproducibility of Mammography Units, Film Processing and Quality Imaging
NASA Astrophysics Data System (ADS)
Gaona, Enrique
2003-09-01
The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image.
Grandl, Susanne; Scherer, Kai; Sztrókay-Gaul, Anikó; Birnbacher, Lorenz; Willer, Konstantin; Chabior, Michael; Herzen, Julia; Mayr, Doris; Auweter, Sigrid D; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin
2015-12-01
Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.
Haddad, Fady G; Kourie, Hampig Raphael; Adib, Salim M
2015-12-01
In Lebanon, annual national breast awareness campaigns were started in 2002 during the international breast month of October to promote the utilization of mammography for women aged ≥ 40. The impact of the campaigns has been assessed periodically since 2003. Results of 2003-2005 campaigns have been published previously. To measure the prevalence of two behavioral outcomes of interest: ever-use of mammography, and repeat mammography in the previous 12 months among ever-users. The prevalence was described by region and age group. The aim was to document the effectiveness of the program towards reaching a nationally defined goal of 80% screening coverage. The survey's sampling frame was developed incrementally, and since 2005 it has included women aged ≥ 40 from all areas of Lebanon. The sample size has also increased incrementally from 1200 in 2005 to 2400 in 2013. Results have been tabulated biannually and presented as historical trends with regional and demographic variations covering a 9-year period. In all six consecutive surveys presented here, the mean age of participating women was about 50 years. Year-by-year increases in utilization indicators were detected, with consistent differences in favor of the more urban areas in and around the capital city Beirut and its suburbs (Greater Beirut or GB). By 2013, ever-utilization had reached 43% (41-45) and recent mammography 20% (18-22) nationwide. Utilization was significantly more important in the age group 50-59 compared with the age group 40-49 or ≥ 60. While recent rates have increased nationwide, they have reached a plateau of about 25% in GB and are tending to the same level in other areas. While initial progress was slow, it has been accelerating in the last 4-5 years, indicating that the message is being accepted by a larger audience of targeted women at each iteration. However, concern remains that women between 40 and 50 and those >60 are not responding as well as desired to the screening message, for reasons currently under investigation. Copyright © 2015 Elsevier Ltd. All rights reserved.
2003-06-18
Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...34Digital Mammography Breast Dosimetry Using Copper- Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs )" Author: LT John J. Tomon...Title of Thesis: " Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent
Seitz, Holli H; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M; Armstrong, Katrina; Cappella, Joseph N
2016-10-01
This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. 2918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (<1.5%; ≥1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) x 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk ≤1.5%. For women with a risk≤1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Seitz, Holli H.; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M.; Armstrong, Katrina; Cappella, Joseph N.
2016-01-01
Objective This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. Methods 2,918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (< 1.5%; ≥ 1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) × 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Results Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk <1.5%. For women with a risk < 1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. Conclusion A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Practice Implications Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. PMID:27178707
MASTOS: Mammography Simulation Tool for design Optimization Studies.
Spyrou, G; Panayiotakis, G; Tzanakos, G
2000-01-01
Mammography is a high quality imaging technique for the detection of breast lesions, which requires dedicated equipment and optimum operation. The design parameters of a mammography unit have to be decided and evaluated before the construction of such a high cost of apparatus. The optimum operational parameters also must be defined well before the real breast examination. MASTOS is a software package, based on Monte Carlo methods, that is designed to be used as a simulation tool in mammography. The input consists of the parameters that have to be specified when using a mammography unit, and also the parameters specifying the shape and composition of the breast phantom. In addition, the input may specify parameters needed in the design of a new mammographic apparatus. The main output of the simulation is a mammographic image and calculations of various factors that describe the image quality. The Monte Carlo simulation code is PC-based and is driven by an outer shell of a graphical user interface. The entire software package is a simulation tool for mammography and can be applied in basic research and/or in training in the fields of medical physics and biomedical engineering as well as in the performance evaluation of new designs of mammography units and in the determination of optimum standards for the operational parameters of a mammography unit.
Dibden, A; Offman, J; Parmar, D; Jenkins, J; Slater, J; Binysh, K; McSorley, J; Scorfield, S; Cumming, P; Liao, X-H; Ryan, M; Harker, D; Stevens, G; Rogers, N; Blanks, R; Sellars, S; Patnick, J; Duffy, S W
2014-01-01
Background: The introduction of two-view mammography at incident (subsequent) screens in the National Health Service Breast Screening Programme (NHSBSP) has led to an increased number of cancers detected at screen. However, the effect of two-view mammography on interval cancer rates has yet to be assessed. Methods: Routine screening and interval cancer data were collated from all screening programmes in the United Kingdom for women aged 50–64, screened between 1 April 2003 and 31 March 2005. Interval cancer rates were compared based on whether two-view mammography was in use at the last routine screen. Results: The reduction in interval cancers following screening using two-view mammography compared with one view was 0.68 per 1 000 women screened. Overall, this suggests the introduction of two-view mammography at incident screen was accompanied by a 15–20% reduction in interval cancer rates in the NHSBSP. Conclusion: The introduction of two-view mammography at incident screens is associated with a reduction in incidence of interval cancers. This is consistent with previous publications on a contemporaneous increase in screen-detected cancers. The results provide further evidence of the benefit of the use of two-view mammography at incident screens. PMID:24366303
21 CFR 900.12 - Quality standards.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MAMMOGRAPHY... to mammography. The training shall include instruction in radiation physics, including radiation physics specific to mammography, radiation effects, and radiation protection. The mammographic...
A review of screening mammography participation and utilization in Canada.
Doyle, G P; Major, D; Chu, C; Stankiewicz, A; Harrison, M L; Pogany, L; Mai, V M; Onysko, J
2011-09-01
Participation rate is an important indicator for a screening program's effectiveness; however, the current approach to measuring participation rate in Canada is not comparable with other countries. The objective of this study is to review the measurement of screening mammography participation in Canada, make international comparisons, and propose alternative methods. Canadian breast cancer screening program data for women aged 50 to 69 years screened between 2004 and 2006 were extracted from the Canadian Breast Cancer Screening Database (CBCSD). The fee-for-services (FSS) mammography data (opportunistic screening mammography) were obtained from the provincial ministries of health. Both screening mammography program participation and utilization were examined over 24 and 30 months. Canada's screening participation rate increases from 39.4% for a 24-month cut-off to 43.6% for a 30-month cut-off. The 24-month mammography utilization rate is 63.1% in Canada, and the 30-month utilization rate is 70.4%. Due to the differences in health service delivery among Canadian provinces, both programmatic participation and overall utilization of mammography at 24 months and 30 months should be monitored.
NASA Astrophysics Data System (ADS)
Peixoto, J. G. P.; de Almeida, C. E.
2001-09-01
It is recognized by the international guidelines that it is necessary to offer calibration services for mammography beams in order to improve the quality of clinical diagnosis. Major efforts have been made by several laboratories in order to establish an appropriate and traceable calibration infrastructure and to provide the basis for a quality control programme in mammography. The contribution of the radiation metrology network to the users of mammography is reviewed in this work. Also steps required for the implementation of a mammography calibration system using a constant potential x-ray and a clinical mammography x-ray machine are presented. The various qualities of mammography radiation discussed in this work are in accordance with the IEC 61674 and the AAPM recommendations. They are at present available at several primary standard dosimetry laboratories (PSDLs), namely the PTB, NIST and BEV and a few secondary standard dosimetry laboratories (SSDLs) such as at the University of Wisconsin and at the IAEA's SSDL. We discuss the uncertainties involved in all steps of the calibration chain in accord with the ISO recommendations.
Mammography screening: how important is cost as a barrier to use?
Urban, N; Anderson, G L; Peacock, S
1994-01-01
OBJECTIVES. Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. METHODS. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. RESULTS. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. CONCLUSION. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size. PMID:8279611
Mammography screening: how important is cost as a barrier to use?
Urban, N; Anderson, G L; Peacock, S
1994-01-01
Recent legislation will improve insurance coverage for screening mammography and effectively lower its cost to many women. Although cost has been cited as a barrier to use, evidence of the magnitude of its effect on use is limited. Mammography use in the past 2 years among women aged 50 to 75 residing in four suburban or rural counties in Washington State was estimated from 1989 survey data. Logistic regression analysis was used to estimate the odds ratio of mammography use as a function of economic and other variables. Within a residential area, averages were used to measure the market price of mammography and the time cost to obtain a mammogram. Use was lower among women who faced a higher net price or who preferred to obtain a mammogram during weekend or evening hours and higher among women with higher incomes. Visiting no doctor regularly and smoking were predictors of failure to use mammography. The effects of economic variables on mammography use are important and stable across subsets of the population, but they are modest in size.
Cost-effectiveness of digital mammography screening before the age of 50 in The Netherlands.
Sankatsing, Valérie D V; Heijnsdijk, Eveline A M; van Luijt, Paula A; van Ravesteyn, Nicolien T; Fracheboud, Jacques; de Koning, Harry J
2015-10-15
In the Netherlands, routine mammography screening starts at age 50. This starting age may have to be reconsidered because of the increasing breast cancer incidence among women aged 40 to 49 and the recent implementation of digital mammography. We assessed the cost-effectiveness of digital mammography screening that starts between age 40 and 49, using a microsimulation model. Women were screened before age 50, in addition to the current programme (biennial 50-74). Screening strategies varied in starting age (between 40 and 50) and frequency (annual or biennial). The numbers of breast cancers diagnosed, life-years gained (LYG) and breast cancer deaths averted were predicted and incremental cost-effectiveness ratios (ICERs) were calculated to compare screening scenarios. Biennial screening from age 50 to 74 (current strategy) was estimated to gain 157 life years per 1,000 women with lifelong follow-up, compared to a situation without screening, and cost €3,376/LYG (3.5% discounted). Additional screening increased the number of LYG, compared to no screening, ranging from 168 to 242. The costs to generate one additional LYG (i.e., ICER), comparing a screening strategy to the less intensive alternative, were estimated at €5,329 (biennial 48-74 vs. current strategy), €7,628 (biennial 45-74 vs. biennial 48-74), €10,826 (biennial 40-74 vs. biennial 45-74) and €18,759 (annual 40-49 + biennial 50-74 vs. biennial 40-74). Other strategies (49 + biennial 50-74 and annual 45-49 + biennial 50-74) resulted in less favourable ICERs. These findings show that extending the Dutch screening programme by screening between age 40 and 49 is cost-effective, particularly for biennial strategies. © 2015 UICC.
Cruz-Bastida, Juan P; Rosado-Méndez, Iván M; Villaseñor-Navarro, Yolanda; Pérez-Ponce, Héctor; Galván, Héctor A; Trujillo-Zamudio, Flavio E; Sánchez-Suárez, Patricia; Benítez-Bribiesca, Luis
2016-01-01
Objective: To correlate image parameters in contrast-enhanced digital mammography (CEDM) with blood and lymphatic microvessel density (MVD). Methods: 18 Breast Imaging-Reporting and Data System (BI-RADS)-4 to BI-RADS-5 patients were subjected to CEDM. Craniocaudal views were acquired, two views (low and high energy) before iodine contrast medium (CM) injection and four views (high energy) 1–5 min afterwards. Processing included registration and two subtraction modalities, traditional single-energy temporal (high-energy) and “dual-energy temporal with a matrix”, proposed to improve lesion conspicuity. Images were calibrated into iodine thickness, and iodine uptake, contrast, time–intensity and time–contrast kinetic curves were quantified. Image indicators were compared with MVD evaluated by anti-CD105 and anti-podoplanin (D2-40) immunohistochemistry. Results: 11 lesions were cancerous and 7 were benign. CEDM subtraction strongly increased conspicuity of lesions enhanced by iodine uptake. A strong correlation was observed between lymphatic vessels and blood vessels; all benign lesions had <30 blood microvessels per field, and all cancers had more than this value. MVD showed no correlation with iodine uptake, nor with contrast. The most frequent curve was early uptake followed by plateau for uptake and contrast in benign and malignant lesions. The positive-predictive value of uptake dynamics was 73% and that of contrast was 64%. Conclusion: CEDM increased lesion visibility and showed additional features compared with conventional mammography. Lack of correlation between image parameters and MVD is probably due to tumour tissue heterogeneity, mammography projective nature and/or dependence of extracellular iodine irrigation on tissue composition. Advances in knowledge: Quantitative analysis of CEDM images was performed. Image parameters and MVD showed no correlation. Probably, this is indication of the complex dependence of CM perfusion on tumour microenvironment. PMID:27376457
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, H; Zhou, B; Beidokhti, D
Purpose: To investigate the feasibility of accurate quantification of iodine mass thickness in contrast-enhanced spectral mammography. Methods: Experimental phantom studies were performed on a spectral mammography system based on Si strip photon-counting detectors. Dual-energy images were acquired using 40 kVp and a splitting energy of 34 keV with 3 mm Al pre-filtration. The initial calibration was done with glandular and adipose tissue equivalent phantoms of uniform thicknesses and iodine disk phantoms of various concentrations. A secondary calibration was carried out using the iodine signal obtained from the dual-energy decomposed images and the known background phantom thicknesses and densities. The iodinemore » signal quantification method was validated using phantoms composed of a mixture of glandular and adipose materials, for various breast thicknesses and densities. Finally, the traditional dual-energy weighted subtraction method was also studied as a comparison. The measured iodine signal from both methods was compared to the known iodine concentrations of the disk phantoms to characterize the quantification accuracy. Results: There was good agreement between the iodine mass thicknesses measured using the proposed method and the known values. The root-mean-square (RMS) error was estimated to be 0.2 mg/cm2. The traditional weighted subtraction method also predicted a linear correlation between the measured signal and the known iodine mass thickness. However, the correlation slope and offset values were strongly dependent on the total breast thickness and density. Conclusion: The results of the current study suggest that iodine mass thickness can be accurately quantified with contrast-enhanced spectral mammography. The quantitative information can potentially improve the differentiation between benign and malignant legions. Grant funding from Philips Medical Systems.« less
21 CFR 900.10 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MAMMOGRAPHY QUALITY STANDARDS ACT MAMMOGRAPHY Quality Standards and Certification § 900.10 Applicability. The... States that provide mammography services, with the exception of the Department of Veterans Affairs. ...
Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M
2011-03-01
Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.
Cultural views, language ability, and mammography use in Chinese American women.
Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S
2009-12-01
Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women's ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors' results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population.
Cultural Views, Language Ability, and Mammography Use in Chinese American Women
Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.
2013-01-01
Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women’s ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors’ results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population. PMID:19233947
Nazzal, Zaher; Sholi, Hisham; Sholi, Suha B; Sholi, Mohammad B; Lahaseh, Rawya
2018-02-21
Mammography screening is an effective tool for early detection and management of breast cancer. Female health-care workers' awareness of breast cancer screening is important because their beliefs and behaviours could influence other women. The aim of this study was to assess mammography screening uptake by female health-care workers at primary health-care centres and to identify the primary motivators and barriers that affect uptake. This cross-sectional study included all governmental primary health-care centres in the West Bank. Governorates were grouped into three regions as follows: north West Bank (Nablus, Jenin, Tulkarm, Tubas, Qalqiliya, and Salfit), middle West Bank (Jerusalem, Jericho, and Ramallah), and south West Bank (Hebron, and Bethlehem). The study population included all female health-care workers older than 40 years. Those who performed mammography for a suspected mass or other breast abnormalities were excluded. A self-administered questionnaire was used to collect data on demographic characteristics, knowledge about mammography screening, the extent and regularity of mammography screening, and motivators and barriers influencing their mammography screening uptake. The rate of mammography screening uptake was calculated. χ 2 test and t tests were used to assess screening motivators and barriers. The study was approved by the Institutional Review Board of the An-Najah National University. Participation was voluntary, and written consent was obtained from each participant. 299 female health-care workers completed a self-administered questionnaire. The mean age of the participants was 46 years (SD 4·7). 284 (95%) women had adequate knowledge about breast cancer and mammography screening, and 149 (50%) women reported having had at least one mammogram. 62 (21%) women had had regular scheduled mammograms. The most frequent reported motivators were the perceived benefit that early detection of breast cancer is important for its management (269 [90%] women) and the belief that mammography can detect breast cancer before its symptoms appear (251 [84%] women). The most frequent barrier to mammography screening was being busy (140 [47%] women) and the lack of perceived susceptibility (125 [42%] women). Mammography screening was suboptimal in a population of female health-care workers. Educational interventions are needed to remove barriers that limit compliance to recommendations and to emphasise the importance of early detection in breast cancer management. Ensuring the availability and accessibility of screening services, particularly for health-care workers within their work settings, would improve the acceptance and compliance for mammography screening programmes. None. Copyright © 2018 Elsevier Ltd. All rights reserved.
[Programs of early detection of breast cancer and access of mammography in Spain].
Luengo, S; Azcona, B; Lázaro, P; Madero, R
1997-05-24
We studied availability to mammography among Spanish women aged 40 to 70 years, variation in use of the mammography by autonomous community, and the situation and importance of breast cancer screening programs among other factors, in the access to mammography. A cross-sectional population survey was conducted in 1994 in a sample of 3,218 women. A questionnaire was used to collect data on the variable access (receipt of at least one mammogram in the last 2 years) as well as different access-related variables. Information on breast cancer screening programs was collected by contacting the responsible institutions. We considered that a program had total coverage if it included all the municipalities in the province and partial if it did not include all municipalities. Twenty-eight percent of women had performed a mammogram. This proportion varied among autonomous communities (AACC) from 11.5 to 73.8%. Breast cancer screening programs existed in 8 AACC. The multivariant analysis revealed an association between access to mammography and the existence of a screening program, especially when the later had total coverage (OR = 7.64; 95% CI = 5.24-11.10). An association was also found between access to mammography and physician-related factors, place of residence and attitudes of women toward mammography. Less than one third of women aged 40-70 have performed a mammography in the last 2 years, and this proportion varies among AACC. Gynecologist visits and the existence of breast cancer screening programs are fundamental factors in the access to mammography in Spain.
Schousboe, John T; Kerlikowske, Karla; Loh, Andrew; Cummings, Steven R
2011-07-05
Current guidelines recommend mammography every 1 or 2 years starting at age 40 or 50 years, regardless of individual risk for breast cancer. To estimate the cost-effectiveness of mammography by age, breast density, history of breast biopsy, family history of breast cancer, and screening interval. Markov microsimulation model. Surveillance, Epidemiology, and End Results program, Breast Cancer Surveillance Consortium, and the medical literature. U.S. women aged 40 to 49, 50 to 59, 60 to 69, and 70 to 79 years with initial mammography at age 40 years and breast density of Breast Imaging Reporting and Data System (BI-RADS) categories 1 to 4. Lifetime. National health payer. Mammography annually, biennially, or every 3 to 4 years or no mammography. Costs per quality-adjusted life-year (QALY) gained and number of women screened over 10 years to prevent 1 death from breast cancer. Biennial mammography cost less than $100,000 per QALY gained for women aged 40 to 79 years with BI-RADS category 3 or 4 breast density or aged 50 to 69 years with category 2 density; women aged 60 to 79 years with category 1 density and either a family history of breast cancer or a previous breast biopsy; and all women aged 40 to 79 years with both a family history of breast cancer and a previous breast biopsy, regardless of breast density. Biennial mammography cost less than $50,000 per QALY gained for women aged 40 to 49 years with category 3 or 4 breast density and either a previous breast biopsy or a family history of breast cancer. Annual mammography was not cost-effective for any group, regardless of age or breast density. Mammography is expensive if the disutility of false-positive mammography results and the costs of detecting nonprogressive and nonlethal invasive cancer are considered. Results are not applicable to carriers of BRCA1 or BRCA2 mutations. Mammography screening should be personalized on the basis of a woman's age, breast density, history of breast biopsy, family history of breast cancer, and beliefs about the potential benefit and harms of screening. Eli Lilly, Da Costa Family Foundation for Research in Breast Cancer Prevention of the California Pacific Medical Center, and Breast Cancer Surveillance Consortium.
Lehman, Constance D; Arao, Robert F; Sprague, Brian L; Lee, Janie M; Buist, Diana S M; Kerlikowske, Karla; Henderson, Louise M; Onega, Tracy; Tosteson, Anna N A; Rauscher, Garth H; Miglioretti, Diana L
2017-04-01
Purpose To establish performance benchmarks for modern screening digital mammography and assess performance trends over time in U.S. community practice. Materials and Methods This HIPAA-compliant, institutional review board-approved study measured the performance of digital screening mammography interpreted by 359 radiologists across 95 facilities in six Breast Cancer Surveillance Consortium (BCSC) registries. The study included 1 682 504 digital screening mammograms performed between 2007 and 2013 in 792 808 women. Performance measures were calculated according to the American College of Radiology Breast Imaging Reporting and Data System, 5th edition, and were compared with published benchmarks by the BCSC, the National Mammography Database, and performance recommendations by expert opinion. Benchmarks were derived from the distribution of performance metrics across radiologists and were presented as 50th (median), 10th, 25th, 75th, and 90th percentiles, with graphic presentations using smoothed curves. Results Mean screening performance measures were as follows: abnormal interpretation rate (AIR), 11.6 (95% confidence interval [CI]: 11.5, 11.6); cancers detected per 1000 screens, or cancer detection rate (CDR), 5.1 (95% CI: 5.0, 5.2); sensitivity, 86.9% (95% CI: 86.3%, 87.6%); specificity, 88.9% (95% CI: 88.8%, 88.9%); false-negative rate per 1000 screens, 0.8 (95% CI: 0.7, 0.8); positive predictive value (PPV) 1, 4.4% (95% CI: 4.3%, 4.5%); PPV2, 25.6% (95% CI: 25.1%, 26.1%); PPV3, 28.6% (95% CI: 28.0%, 29.3%); cancers stage 0 or 1, 76.9%; minimal cancers, 57.7%; and node-negative invasive cancers, 79.4%. Recommended CDRs were achieved by 92.1% of radiologists in community practice, and 97.1% achieved recommended ranges for sensitivity. Only 59.0% of radiologists achieved recommended AIRs, and only 63.0% achieved recommended levels of specificity. Conclusion The majority of radiologists in the BCSC surpass cancer detection recommendations for screening mammography; however, AIRs continue to be higher than the recommended rate for almost half of radiologists interpreting screening mammograms. © RSNA, 2016 Online supplemental material is available for this article.
Melnikow, Joy; Fenton, Joshua J.; Whitlock, Evelyn P.; Miglioretti, Diana L.; Weyrich, Meghan S.; Thompson, Jamie H.; Shah, Kunal
2016-01-01
Background Screening mammography has lower sensitivity and specificity in women with dense breasts, who experience higher breast cancer risk. Purpose Systematic review of: reproducibility of BI-RADS density categorization; test performance and clinical outcomes of supplemental screening with breast ultrasound, magnetic resonance imaging (MRI), and digital breast tomosynthesis (DBT) in women with dense breasts and negative mammography. Data Sources MEDLINE, PubMed, Embase, and Cochrane January 2000–July 2015. Study Selection Studies reporting BI-RADS density reproducibility or supplemental screening results for women with dense breasts. Data Extraction Quality assessment and abstraction of twenty-four studies from seven countries; six were good quality. Data Synthesis Three good-quality studies reported reproducibility of BI-RADS density; 13–19% of women were re-categorized between “dense” and “non-dense” at subsequent screening. Two good-quality studies reported ultrasound sensitivity for women with negative mammography ranging from 80–83%; specificity 86–94%; and positive predictive value (PPV) 3–8%. MRI sensitivity ranged from 75–100%, specificity 78–94%, and PPV 3–33% (3 studies). Ultrasound additional cancer detection rates were 4.4 per 1,000 exams (89–93% invasive); recall rates were 14%. MRI detected 3.5–28.6 additional cancers per 1,000 exams (34–86% invasive); recall rates were 12–24 %. DBT cancer detection rates increased by 1.4–2.5 per 1000 exams compared to mammography alone (3 studies). Recall rates ranged from 7–11%, compared to 7–17% with mammography alone. No studies examined breast cancer outcomes. Limitations Good quality evidence was sparse. Studies were small and confidence intervals were wide. Definitions of recall were absent or inconsistent. Conclusions Density ratings may be re-categorized on serial screening mammograms. Supplemental screening of women with dense breasts finds additional breast cancers, but increases false-positives. DBT may reduce recall rates. Supplemental screening impacts on breast cancer outcomes remain unclear. Primary Funding Source Agency for Healthcare Research and Quality PMID:26757021
Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter
2018-05-14
Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer-reviewed journals. NCT03377036; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Influence of advertisement on women's attitudes toward mammography screening.
Collins, C; Davis, L S; Rentz, K; Vannoy, D
1997-01-01
This project represents an effort to incorporate a feminist perspective into research on mammography screening. The purpose of this study was to assess women's attitudes toward four advertisements designed to encourage mammography screening. The goal was to create awareness about women's attitudes toward mammography advertisements in order to encourage the development of more effective and responsive motivational materials. The results indicated that each ad communicated different messages about the seriousness of breast cancer and the efficacy of mammography in detecting early breast cancer. Each ad also affected women differently regarding their feelings of control over breast cancer, their perceived loss of sex appeal resulting from a breast cancer diagnosis, and their general fear of breast cancer.
Screening and prevention of breast cancer in primary care.
Tice, Jeffrey A; Kerlikowske, Karla
2009-09-01
Mammography remains the mainstay of breast cancer screening. There is little controversy that mammography reduces the risk of dying from breast cancer by about 23% among women between the ages of 50 and 69 years, although the harms associated with false-positive results and overdiagnosis limit the net benefit of mammography. Women in their 70s may have a small benefit from screening mammography, but overdiagnosis increases in this age group as do competing causes of death. While new data support a 16% reduction in breast cancer mortality for 40- to 49-year-old women after 10 years of screening, the net benefit is less compelling in part because of the lower incidence of breast cancer in this age group and because mammography is less sensitive and specific in women younger than 50 years. Digital mammography is more sensitive than film mammography in young women with similar specificity, but no improvements in breast cancer outcomes have been demonstrated. Magnetic resonance imaging may benefit the highest risk women. Randomized trials suggest that self-breast examination does more harm than good. Primary prevention with currently approved medications will have a negligible effect on breast cancer incidence. Public health efforts aimed at increasing mammography screening rates, promoting regular exercise in all women, maintaining a healthy weight, limiting alcohol intake, and limiting postmenopausal hormone therapy may help to continue the recent trend of lower breast cancer incidence and mortality among American women.
DAILEY, AMY B.; KASL, STANISLAV V.; JONES, BETH A.
2011-01-01
Objective To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. Methods African American and white women (1451) aged 40–79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Results Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of ≥$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Conclusions Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women. PMID:18321171
Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A
2008-03-01
ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.
Evolutionary fuzzy modeling human diagnostic decisions.
Peña-Reyes, Carlos Andrés
2004-05-01
Fuzzy CoCo is a methodology, combining fuzzy logic and evolutionary computation, for constructing systems able to accurately predict the outcome of a human decision-making process, while providing an understandable explanation of the underlying reasoning. Fuzzy logic provides a formal framework for constructing systems exhibiting both good numeric performance (accuracy) and linguistic representation (interpretability). However, fuzzy modeling--meaning the construction of fuzzy systems--is an arduous task, demanding the identification of many parameters. To solve it, we use evolutionary computation techniques (specifically cooperative coevolution), which are widely used to search for adequate solutions in complex spaces. We have successfully applied the algorithm to model the decision processes involved in two breast cancer diagnostic problems, the WBCD problem and the Catalonia mammography interpretation problem, obtaining systems both of high performance and high interpretability. For the Catalonia problem, an evolved system was embedded within a Web-based tool-called COBRA-for aiding radiologists in mammography interpretation.
Galván-Tejada, Carlos E.; Zanella-Calzada, Laura A.; Galván-Tejada, Jorge I.; Celaya-Padilla, José M.; Gamboa-Rosales, Hamurabi; Garza-Veloz, Idalia; Martinez-Fierro, Margarita L.
2017-01-01
Breast cancer is an important global health problem, and the most common type of cancer among women. Late diagnosis significantly decreases the survival rate of the patient; however, using mammography for early detection has been demonstrated to be a very important tool increasing the survival rate. The purpose of this paper is to obtain a multivariate model to classify benign and malignant tumor lesions using a computer-assisted diagnosis with a genetic algorithm in training and test datasets from mammography image features. A multivariate search was conducted to obtain predictive models with different approaches, in order to compare and validate results. The multivariate models were constructed using: Random Forest, Nearest centroid, and K-Nearest Neighbor (K-NN) strategies as cost function in a genetic algorithm applied to the features in the BCDR public databases. Results suggest that the two texture descriptor features obtained in the multivariate model have a similar or better prediction capability to classify the data outcome compared with the multivariate model composed of all the features, according to their fitness value. This model can help to reduce the workload of radiologists and present a second opinion in the classification of tumor lesions. PMID:28216571
Galván-Tejada, Carlos E; Zanella-Calzada, Laura A; Galván-Tejada, Jorge I; Celaya-Padilla, José M; Gamboa-Rosales, Hamurabi; Garza-Veloz, Idalia; Martinez-Fierro, Margarita L
2017-02-14
Breast cancer is an important global health problem, and the most common type of cancer among women. Late diagnosis significantly decreases the survival rate of the patient; however, using mammography for early detection has been demonstrated to be a very important tool increasing the survival rate. The purpose of this paper is to obtain a multivariate model to classify benign and malignant tumor lesions using a computer-assisted diagnosis with a genetic algorithm in training and test datasets from mammography image features. A multivariate search was conducted to obtain predictive models with different approaches, in order to compare and validate results. The multivariate models were constructed using: Random Forest, Nearest centroid, and K-Nearest Neighbor (K-NN) strategies as cost function in a genetic algorithm applied to the features in the BCDR public databases. Results suggest that the two texture descriptor features obtained in the multivariate model have a similar or better prediction capability to classify the data outcome compared with the multivariate model composed of all the features, according to their fitness value. This model can help to reduce the workload of radiologists and present a second opinion in the classification of tumor lesions.
NASA Astrophysics Data System (ADS)
Mazurowski, Maciej A.; Zhang, Jing; Lo, Joseph Y.; Kuzmiak, Cherie M.; Ghate, Sujata V.; Yoon, Sora
2014-03-01
Providing high quality mammography education to radiology trainees is essential, as good interpretation skills potentially ensure the highest benefit of screening mammography for patients. We have previously proposed a computer-aided education system that utilizes trainee models, which relate human-assessed image characteristics to interpretation error. We proposed that these models be used to identify the most difficult and therefore the most educationally useful cases for each trainee. In this study, as a next step in our research, we propose to build trainee models that utilize features that are automatically extracted from images using computer vision algorithms. To predict error, we used a logistic regression which accepts imaging features as input and returns error as output. Reader data from 3 experts and 3 trainees were used. Receiver operating characteristic analysis was applied to evaluate the proposed trainee models. Our experiments showed that, for three trainees, our models were able to predict error better than chance. This is an important step in the development of adaptive computer-aided education systems since computer-extracted features will allow for faster and more extensive search of imaging databases in order to identify the most educationally beneficial cases.
Engaging diverse underserved communities to bridge the mammography divide.
Engelman, Kimberly K; Cupertino, Ana Paula; Daley, Christine M; Long, Trish; Cully, Angelia; Mayo, Matthew S; Ellerbeck, Edward F; Geana, Mugur V; Greiner, Allen
2011-01-21
Breast cancer screening continues to be underutilized by the population in general, but is particularly underutilized by traditionally underserved minority populations. Two of the most at risk female minority groups are American Indians/Alaska Natives (AI/AN) and Latinas. American Indian women have the poorest recorded 5-year cancer survival rates of any ethnic group while breast cancer is the number one cause of cancer mortality among Latina women. Breast cancer screening rates for both minority groups are near or at the lowest among all racial/ethnic groups. As with other health screening behaviors, women may intend to get a mammogram but their intentions may not result in initiation or follow through of the examination process. An accumulating body of research, however, demonstrates the efficacy of developing 'implementation intentions' that define when, where, and how a specific behavior will be performed. The formulation of intended steps in addition to addressing potential barriers to test completion can increase a person's self-efficacy, operationalize and strengthen their intention to act, and close gaps between behavioral intention and completion. To date, an evaluation of the formulation of implementation intentions for breast cancer screening has not been conducted with minority populations. In the proposed program, community health workers will meet with rural-dwelling Latina and American Indian women one-on-one to educate them about breast cancer and screening and guide them through a computerized and culturally tailored "implementation intentions" program, called Healthy Living Kansas-Breast Health, to promote breast cancer screening utilization. We will target Latina and AI/AN women from two distinct rural Kansas communities. Women attending community events will be invited by CHWs to participate and be randomized to either a mammography "implementation intentions" (MI2) intervention or a comparison general breast cancer prevention informational intervention (C). CHWs will be armed with notebook computers loaded with our Healthy Living Kansas-Breast Health program and guide their peers through the program. Women in the MI2 condition will receive assistance with operationalizing their screening intentions and identifying and addressing their stated screening barriers with the goal of guiding them toward accessing screening services near their community. Outcomes will be evaluated at 120-days post randomization via self-report and will include mammography utilization status, barriers, and movement along a behavioral stages of readiness to screen model. This highly innovative project will be guided and initiated by AI/AN and Latina community members and will test the practical application of emerging behavioral theory among minority persons living in rural communities.
Engaging diverse underserved communities to bridge the mammography divide
2011-01-01
Background Breast cancer screening continues to be underutilized by the population in general, but is particularly underutilized by traditionally underserved minority populations. Two of the most at risk female minority groups are American Indians/Alaska Natives (AI/AN) and Latinas. American Indian women have the poorest recorded 5-year cancer survival rates of any ethnic group while breast cancer is the number one cause of cancer mortality among Latina women. Breast cancer screening rates for both minority groups are near or at the lowest among all racial/ethnic groups. As with other health screening behaviors, women may intend to get a mammogram but their intentions may not result in initiation or follow through of the examination process. An accumulating body of research, however, demonstrates the efficacy of developing 'implementation intentions' that define when, where, and how a specific behavior will be performed. The formulation of intended steps in addition to addressing potential barriers to test completion can increase a person's self-efficacy, operationalize and strengthen their intention to act, and close gaps between behavioral intention and completion. To date, an evaluation of the formulation of implementation intentions for breast cancer screening has not been conducted with minority populations. Methods/Design In the proposed program, community health workers will meet with rural-dwelling Latina and American Indian women one-on-one to educate them about breast cancer and screening and guide them through a computerized and culturally tailored "implementation intentions" program, called Healthy Living Kansas - Breast Health, to promote breast cancer screening utilization. We will target Latina and AI/AN women from two distinct rural Kansas communities. Women attending community events will be invited by CHWs to participate and be randomized to either a mammography "implementation intentions" (MI2) intervention or a comparison general breast cancer prevention informational intervention (C). CHWs will be armed with notebook computers loaded with our Healthy Living Kansas - Breast Health program and guide their peers through the program. Women in the MI2 condition will receive assistance with operationalizing their screening intentions and identifying and addressing their stated screening barriers with the goal of guiding them toward accessing screening services near their community. Outcomes will be evaluated at 120-days post randomization via self-report and will include mammography utilization status, barriers, and movement along a behavioral stages of readiness to screen model. Discussion This highly innovative project will be guided and initiated by AI/AN and Latina community members and will test the practical application of emerging behavioral theory among minority persons living in rural communities. Trial Registration ClinicalTrials (NCT): NCT01267110 PMID:21255424
Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin
2011-08-01
Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.
Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement.
2009-11-17
Update of the 2002 U.S. Preventive Services Task Force (USPSTF) recommendation statement on screening for breast cancer in the general population. The USPSTF examined the evidence on the efficacy of 5 screening modalities in reducing mortality from breast cancer: film mammography, clinical breast examination, breast self-examination, digital mammography, and magnetic resonance imaging in order to update the 2002 recommendation. To accomplish this update, the USPSTF commissioned 2 studies: 1) a targeted systematic evidence review of 6 selected questions relating to benefits and harms of screening, and 2) a decision analysis that used population modeling techniques to compare the expected health outcomes and resource requirements of starting and ending mammography screening at different ages and using annual versus biennial screening intervals. The USPSTF recommends against routine screening mammography in women aged 40 to 49 years. The decision to start regular, biennial screening mammography before the age of 50 years should be an individual one and take into account patient context, including the patient's values regarding specific benefits and harms. (Grade C recommendation) The USPSTF recommends biennial screening mammography for women between the ages of 50 and 74 years. (Grade B recommendation) The USPSTF concludes that the current evidence is insufficient to assess the additional benefits and harms of screening mammography in women 75 years or older. (I statement) The USPSTF concludes that the current evidence is insufficient to assess the additional benefits and harms of clinical breast examination beyond screening mammography in women 40 years or older. (I statement) The USPSTF recommends against clinicians teaching women how to perform breast self-examination. (Grade D recommendation) The USPSTF concludes that the current evidence is insufficient to assess additional benefits and harms of either digital mammography or magnetic resonance imaging instead of film mammography as screening modalities for breast cancer. (I statement).
Healthcare access and mammography screening in Michigan: a multilevel cross-sectional study
2012-01-01
Background Breast cancer screening rates have increased over time in the United States. However actual screening rates appear to be lower among black women compared with white women. Purpose To assess determinants of breast cancer screening among women in Michigan USA, focusing on individual and neighborhood socio-economic status and healthcare access. Methods Data from 1163 women ages 50-74 years who participated in the 2008 Michigan Special Cancer Behavioral Risk Factor Survey were analyzed. County-level SES and healthcare access were obtained from the Area Resource File. Multilevel logistic regression models were fit using SAS Proc Glimmix to account for clustering of individual observations by county. Separate models were fit for each of the two outcomes of interest; mammography screening and clinical breast examination. For each outcome, two sequential models were fit; a model including individual level covariates and a model including county level covariates. Results After adjusting for misclassification bias, overall cancer screening rates were lower than reported by survey respondents; black women had lower mammography screening rates but higher clinical breast examination rates than white women. However, after adjusting for other individual level variables, race was not a significant predictor of screening. Having health insurance or a usual healthcare provider were the most important predictors of cancer screening. Discussion Access to healthcare is important to ensuring appropriate cancer screening among women in Michigan. PMID:22436125
Dunn, Richard A; Tan, Andrew; Samad, Ismail
2010-01-01
Breast self-examination (BSE) was evaluated to see if it is a significant predictor of mammography. The decisions of females above age 40 in Malaysia to test for breast cancer using BSE and mammography are jointly modeled using a bivariate probit so that unobserved attributes affecting mammography usage are also allowed to affect BSE. Data come from the Malaysia Non-Communicable Disease Surveillance-1, which was collected between September 2005 and February 2006. Having ever performed BSE is positively associated with having ever undergone mammography among Malay (adjusted OR=7.343, CI=2.686, 20.079) and Chinese (adjusted OR=3.466, CI=1.330, 9.031) females after adjusting for household income, education, marital status and residential location. Neither relationship is affected by jointly modelling the decision problem. Although the association is also positive for Indian females when mammography is modelled separately (adjusted OR=5.959, CI=1.546 - 22.970), the relationship is reversed when both decisions are modelled separately. De-emphasizing BSE in Malaysia may reduce mammography screening among a large proportion of the population. Previous work on the issue in developed countries may not apply to nations with limited resources.
Jeukens, Cécile R L P N; Lalji, Ulrich C; Meijer, Eduard; Bakija, Betina; Theunissen, Robin; Wildberger, Joachim E; Lobbes, Marc B I
2014-10-01
Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.
Mammography Prevalence within 2 Two Years (Age 40+) - Small Area Estimates
For mammography, a woman 40 years of age or older must have reported having at least one mammography in her life. Furthermore, she should have had the most recent one within the last two years by the time of interview.
Romero Martín, Sara; Raya Povedano, Jose Luis; Cara García, María; Santos Romero, Ana Luz; Pedrosa Garriguet, Margarita; Álvarez Benito, Marina
2018-06-01
To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis. Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed. In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (p<0.001) and 44.4 % (p<0.001), respectively. With double reading of both techniques, there was an increase in cancer detection of 17.4 % (p = 0.004) and a decrease in recalls of 12.5 % (p = 0.001) with tomosynthesis. Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis. • Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.
Lewis, Carmen L; Pignone, Michael P; Sheridan, Stacey L; Downs, Stephen M; Kinsinger, Linda S
2003-11-01
To assess the effect of providing structured information about the benefits and harms of mammography in differing frames on women's perceptions of screening. Randomized control trial. General internal medicine academic practice. One hundred seventy-nine women aged 35 through 49. Women received 1 of 3 5-minute videos about the benefits and harms of screening mammography in women aged 40 to 49. These videos differed only in the way the probabilities of potential outcomes were framed (positive, neutral, or negative). We measured the change in accurate responses to questions about potential benefits and harms of mammography, and the change in the proportion of participants who perceived that the benefits of mammography were more important than the harms. Before seeing the videos, women's knowledge about the benefits and harms of mammography was inaccurate (82% responded incorrectly to all 3 knowledge questions). After seeing the videos, the proportion that answered correctly increased by 52%, 43%, and 30% for the 3 knowledge questions, respectively, but there were no differences between video frames. At baseline, most women thought the benefits of mammography outweighed the harms (79% positive frame, 80% neutral frame, and 85% negative frame). After the videos, these proportions were similar among the 3 groups (84%, 81%, 83%, P =.93). Women improved the accuracy of their responses to questions about the benefits and harms of mammography after seeing the videos, but this change was not affected by the framing of information. Women strongly perceived that the benefits of mammography outweighed the harms, and providing accurate information had no effect on these perceptions, regardless of how it was framed.
NASA Astrophysics Data System (ADS)
Cunha, Diego M.; Tomal, Alessandra; Poletti, Martin E.
2013-04-01
In this work, the Monte Carlo (MC) code PENELOPE was employed for simulation of x-ray spectra in mammography and contrast-enhanced digital mammography (CEDM). Spectra for Mo, Rh and W anodes were obtained for tube potentials between 24-36 kV, for mammography, and between 45-49 kV, for CEDM. The spectra obtained from the simulations were analytically filtered to correspond to the anode/filter combinations usually employed in each technique (Mo/Mo, Rh/Rh and W/Rh for mammography and Mo/Cu, Rh/Cu and W/Cu for CEDM). For the Mo/Mo combination, the simulated spectra were compared with those obtained experimentally, and for spectra for the W anode, with experimental data from the literature, through comparison of distribution shape, average energies, half-value layers (HVL) and transmission curves. For all combinations evaluated, the simulated spectra were also compared with those provided by different models from the literature. Results showed that the code PENELOPE provides mammographic x-ray spectra in good agreement with those experimentally measured and those from the literature. The differences in the values of HVL ranged between 2-7%, for anode/filter combinations and tube potentials employed in mammography, and they were less than 5% for those employed in CEDM. The transmission curves for the spectra obtained also showed good agreement compared to those computed from reference spectra, with average relative differences less than 12% for mammography and CEDM. These results show that the code PENELOPE can be a useful tool to generate x-ray spectra for studies in mammography and CEDM, and also for evaluation of new x-ray tube designs and new anode materials.
At what age should screening mammography be recommended for Asian women?
Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi
2015-07-01
Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40-49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Self-Report Versus Medical Record for Mammography Screening Among Minority Women.
Nandy, Karabi; Menon, Usha; Szalacha, Laura A; Park, HanJong; Lee, Jongwon; Lee, Eunice E
2016-12-01
Self-report is the most common means of obtaining mammography screening data. The purpose of this study was to assess the accuracy of minority women's self-reported mammography by comparing their self-reported dates of mammograms with those in their medical records from a community-based randomized control trial. We found that out of 192 women, 116 signed the Health Information Portability and Accountability Act form and, among these, 97 had medical records that could be verified (97 / 116 = 83.6%). Ninety-two records matched where both sources confirmed a mammogram; 48 of 92 (52.2%) matched perfectly on self-reported date of mammogram. Complexities in the verification process warrant caution when verifying self-reported mammography screening in minority populations. In spite of some limitations, our findings support the usage of self-reported data on mammography as a validated tool for other researchers investigating mammography screening among minority women who continue to have low screening rates. © The Author(s) 2016.
21 CFR 900.21 - Application for approval as a certification agency.
Code of Federal Regulations, 2010 CFR
2010-04-01
... description of the mammography quality standards the applicant will require facilities to meet and, for those... certification standards the applicant will require facilities to meet are the quality standards published under... SERVICES (CONTINUED) MAMMOGRAPHY QUALITY STANDARDS ACT MAMMOGRAPHY States as Certifiers § 900.21...
ERIC Educational Resources Information Center
2003
The Science Communication Interest Group of the proceedings contains the following 7 papers: "Risk Perceptions and Food Safety: A Test of the Psychometric Paradigm" (Joye C. Gordon); "An Entertainment-Education Video as a Tool to Influence Mammography Compliance Behavior in Latinas" (Gail D. Love); "Promise or Peril: How…
Rimawi, Bassam H; Green, Victoria; Lindsay, Michael
2016-06-01
The purpose of this article is to review the fetal and long-term implications of diagnostic radiation exposure during pregnancy. Evidence-based recommendations for radiologic imaging modalities utilizing exposure of diagnostic radiation during pregnancy, including conventional screen-film mammography, digital mammography, tomosynthesis, and contrast-enhanced mammography are described.
Barriers to Mammography among Inadequately Screened Women
ERIC Educational Resources Information Center
Stoll, Carolyn R. T.; Roberts, Summer; Cheng, Meng-Ru; Crayton, Eloise V.; Jackson, Sherrill; Politi, Mary C.
2015-01-01
Mammography use has increased over the past 20 years, yet more than 30% of women remain inadequately screened. Structural barriers can deter individuals from screening, however, cognitive, emotional, and communication barriers may also prevent mammography use. This study sought to identify the impact of number and type of barriers on mammography…
Perrenoud, Caroline; Stiefel, Friedrich; Bourquin, Céline
2018-06-01
The Swiss Medical Board (SMB) has recently revived the controversy over mammography screening by recommending to stop the introduction of new systematic mammography screening programs. This study aimed to examine the Swiss media coverage of the release of the SMB report. The dataset consisted of 25 newspaper and "medical magazine" articles, and TV/radio interviews. The analytic approach was based on argumentation theory. Authority and community arguments were the most frequent types of arguments. With respect to authority arguments, stakeholders for instance challenged or supported the expertise of the SMB by referring to the competence of external figures of authority. Community arguments were based on common values such as life (saved thanks to systematic mammography screening) and money (costs associated with unnecessary care induced by systematic mammography screening). The efficiency of mammography screening which was the key issue of the debate appeared to be largely eluded, and the question of what women should do endures. While interpersonal and interprofessional communication has become a major topic of interest in the medical community, it appears that media communication on mammography screening is still rather ineffective. We call in particular for a more fact-based discussion. Copyright © 2017 Elsevier B.V. All rights reserved.
Screening mammography--early detection or over-diagnosis? Contribution from Australian data.
Bell, R J
2014-12-01
The aim of this review was to examine the benefits and harms of organized screening mammography, with particular reference to data from Australia. Published literature was examined relating to the impact of screening mammography on breast cancer-specific mortality, the trends in use of adjuvant treatments for breast cancer, the effectiveness of adjuvant treatment in terms of breast cancer-specific mortality, the impact of breast cancer treatment on non-breast cancer mortality and the magnitude of the issue of over-diagnosis. Most of the recent reduction in breast cancer-specific mortality is explained by use of adjuvant therapy rather than screening mammography. The impact of screening mammography in countries where women present with early disease and have access to adjuvant treatment is modest. There is a wide range of estimates for the magnitude of over-diagnosis. All-cause mortality (rather than breast cancer-specific mortality) should be used when assessing the impact of mammographic screening as otherwise the harm of breast cancer treatment in women who are over-diagnosed will be missed. The benefits and harms of screening mammography are finely balanced. The impact of screening mammography is at best neutral but may result in overall harm. Women should be informed of the issue of over-diagnosis. It is time to review whether organized mammographic screening programs should continue.
Knowledge, attitude and practice of mammography among women users of public health services.
Marinho, Luiz Alberto Barcelos; Cecatti, José Guilherme; Osis, Maria José Duarte; Gurgel, Maria Salete Costa
2008-04-01
To evaluate knowledge, attitude and practice related to mammography among women users of local health services, identifying barriers to its performance. A total of 663 women were interviewed at 13 local health centers in a city of Southeastern Brazil, in 2001. Interviewees were randomly selected at each center and they were representative from different socioeconomic conditions. The number of interviewees at each center was proportional to monthly mean appointments. For data analysis, answers were described as knowledge, attitude, practice and their respective adequacies and then they were correlated with control variables through the chi-square test. Only 7.4% of the interviewees had adequate knowledge on mammography, while 97.1% of women had an adequate attitude. The same was seen for the practice of mammography that was adequate in 35.7% of the cases. The main barrier to mammography was lack of referral by physicians working at the health center (81.8%). There was an association between adequacy of attitude and five years or more of education and being married. There was also an association between adequacy of mammography practice and being employed and family income up to four minimum wages. Women users of local health services had no adequate knowledge and practice related to mammography despite having an adequate attitude about this exam.
Contrast-enhanced spectral mammography in patients with MRI contraindications.
Richter, Vivien; Hatterman, Valerie; Preibsch, Heike; Bahrs, Sonja D; Hahn, Markus; Nikolaou, Konstantin; Wiesinger, Benjamin
2017-01-01
Background Contrast-enhanced spectral mammography (CESM) is a novel breast imaging technique providing comparable diagnostic accuracy to breast magnetic resonance imaging (MRI). Purpose To show that CESM in patients with MRI contraindications is feasible, accurate, and useful as a problem-solving tool, and to highlight its limitations. Material and Methods A total of 118 patients with MRI contraindications were examined by CESM. Histology was obtained in 94 lesions and used as gold standard for diagnostic accuracy calculations. Imaging data were reviewed retrospectively for feasibility, accuracy, and technical problems. The diagnostic yield of CESM as a problem-solving tool and for therapy response evaluation was reviewed separately. Results CESM was more accurate than mammography (MG) for lesion categorization (r = 0.731, P < 0.0001 vs. r = 0.279, P = 0.006) and for lesion size estimation (r = 0.738 vs. r = 0.689, P < 0.0001). Negative predictive value of CESM was significantly higher than of MG (85.71% vs. 30.77%, P < 0.0001). When used for problem-solving, CESM changed patient management in 2/8 (25%) cases. Superposition artifacts and timing problems affected diagnostic utility in 3/118 (2.5%) patients. Conclusion CESM is a feasible and accurate alternative for patients with MRI contraindications, but it is necessary to be aware of the method's technical limitations.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Background Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). Patients and Methods With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. Results A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84–12.82). Conclusion DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers. PMID:27611215
Effectiveness of a Mobile Mammography Program.
Stanley, Elizabeth; Lewis, Madelene C; Irshad, Abid; Ackerman, Susan; Collins, Heather; Pavic, Dag; Leddy, Rebecca J
2017-12-01
Mobile mammography units have increasingly been used to address patient health care disparities; however, there are limited data comparing mobile units to stationary sites. This study aims to evaluate the characteristics of women who underwent mammography screening in a mobile unit versus those who underwent mammography screening at a cancer center. In this retrospective study, we analyzed all screening mammography examinations performed in a mobile unit in 2014 (n = 1433 examinations). For comparison, we randomized and reviewed an equivalent number of screening mammography examinations performed at our cancer center in 2014 (n = 1434 examinations). BI-RADS assessment, adherence to follow-up, biopsies performed, cancer detection rate, and sociodemographic variables were recorded. An independent-samples t test was conducted to identify potential differences in age between cancer center patients and mobile unit patients. Chi-square analyses were used to test for associations between location and factors such as health insurance, race, marital status, geographic area, adherence to screening guidelines, recall rate, adherence to follow-up, and cancer detection rates. Patients visiting our cancer center (mean = 57.74 years; SD = 10.55) were significantly older than those visiting the mobile unit (mean = 52.58 years; SD = 8.19; p < 0.001). There was a significant association between location and health insurance status (χ 2 = 610.92; p < 0.001) with more uninsured patients undergoing screening in the mobile van (cancer center = 3.70%, mobile unit = 38.73%). There was a significant association between screening location and patient race (χ 2 = 118.75, p < 0.001), with more white patients being screened at the cancer center (cancer center = 47.28%, mobile unit = 33.30%), more black patients being screened in the mobile van (cancer center = 49.30%, mobile unit = 54.15%), and more Hispanic patients being screened in the mobile van (cancer center = 1.05%, mobile unit = 6.77%). There was a significant association between location and patient marital status (χ 2 = 135.61, p < 0.001), with more married patients screened at the cancer center (cancer center = 49.16%, mobile unit = 38.31%), more single patients screened in the mobile van (cancer center = 25.17%, mobile unit = 34.47%), and more widowed patients being screened at the cancer center (cancer center = 8.09%, mobile unit = 4.47%). There was a significant association between location and geographic area (χ 2 = 33.33, p < 0.001), with both locations reaching more urban than rural patients (cancer center = 79.99%, mobile unit = 70.62%). There was a significant association between location and adherence to screening guidelines (χ 2 = 179.60, p < 0.001), with patients screened at the cancer center being more compliant (cancer center = 56.90%, mobile unit = 34.47%). Finally, there was a significant association between location and recall rate (χ 2 = 4.06, p < 0.001). The cancer center had a lower recall rate (13.32%) than the mobile van (15.98%). Of those patients with BI-RADS 0, there was a significant association between location and adherence to follow-up (χ 2 = 22.75, p < 0.001) with patients using the mobile unit less likely to return for additional imaging (cancer center = 2.65%, mobile unit = 17.03%). Significant differences were found among patients visiting the cancer center versus the mobile mammography van. The cancer center's population is older and more adherent to guidelines, whereas the mobile mammography population exhibited greater racial and marital diversity, higher recall rate, and lack of adherence to follow-up recommendations. By identifying these characteristics, we can develop programs and materials that meet these populations' needs and behaviors, ultimately increasing mammography screening and follow-up rates among underserved populations.
Using multiscale texture and density features for near-term breast cancer risk analysis
Sun, Wenqing; Tseng, Tzu-Liang (Bill); Qian, Wei; Zhang, Jianying; Saltzstein, Edward C.; Zheng, Bin; Lure, Fleming; Yu, Hui; Zhou, Shi
2015-01-01
Purpose: To help improve efficacy of screening mammography by eventually establishing a new optimal personalized screening paradigm, the authors investigated the potential of using the quantitative multiscale texture and density feature analysis of digital mammograms to predict near-term breast cancer risk. Methods: The authors’ dataset includes digital mammograms acquired from 340 women. Among them, 141 were positive and 199 were negative/benign cases. The negative digital mammograms acquired from the “prior” screening examinations were used in the study. Based on the intensity value distributions, five subregions at different scales were extracted from each mammogram. Five groups of features, including density and texture features, were developed and calculated on every one of the subregions. Sequential forward floating selection was used to search for the effective combinations. Using the selected features, a support vector machine (SVM) was optimized using a tenfold validation method to predict the risk of each woman having image-detectable cancer in the next sequential mammography screening. The area under the receiver operating characteristic curve (AUC) was used as the performance assessment index. Results: From a total number of 765 features computed from multiscale subregions, an optimal feature set of 12 features was selected. Applying this feature set, a SVM classifier yielded performance of AUC = 0.729 ± 0.021. The positive predictive value was 0.657 (92 of 140) and the negative predictive value was 0.755 (151 of 200). Conclusions: The study results demonstrated a moderately high positive association between risk prediction scores generated by the quantitative multiscale mammographic image feature analysis and the actual risk of a woman having an image-detectable breast cancer in the next subsequent examinations. PMID:26127038
Heidari, Morteza; Khuzani, Abolfazl Zargari; Hollingsworth, Alan B; Danala, Gopichandh; Mirniaharikandehei, Seyedehnafiseh; Qiu, Yuchen; Liu, Hong; Zheng, Bin
2018-01-30
In order to automatically identify a set of effective mammographic image features and build an optimal breast cancer risk stratification model, this study aims to investigate advantages of applying a machine learning approach embedded with a locally preserving projection (LPP) based feature combination and regeneration algorithm to predict short-term breast cancer risk. A dataset involving negative mammograms acquired from 500 women was assembled. This dataset was divided into two age-matched classes of 250 high risk cases in which cancer was detected in the next subsequent mammography screening and 250 low risk cases, which remained negative. First, a computer-aided image processing scheme was applied to segment fibro-glandular tissue depicted on mammograms and initially compute 44 features related to the bilateral asymmetry of mammographic tissue density distribution between left and right breasts. Next, a multi-feature fusion based machine learning classifier was built to predict the risk of cancer detection in the next mammography screening. A leave-one-case-out (LOCO) cross-validation method was applied to train and test the machine learning classifier embedded with a LLP algorithm, which generated a new operational vector with 4 features using a maximal variance approach in each LOCO process. Results showed a 9.7% increase in risk prediction accuracy when using this LPP-embedded machine learning approach. An increased trend of adjusted odds ratios was also detected in which odds ratios increased from 1.0 to 11.2. This study demonstrated that applying the LPP algorithm effectively reduced feature dimensionality, and yielded higher and potentially more robust performance in predicting short-term breast cancer risk.
NASA Astrophysics Data System (ADS)
Heidari, Morteza; Zargari Khuzani, Abolfazl; Hollingsworth, Alan B.; Danala, Gopichandh; Mirniaharikandehei, Seyedehnafiseh; Qiu, Yuchen; Liu, Hong; Zheng, Bin
2018-02-01
In order to automatically identify a set of effective mammographic image features and build an optimal breast cancer risk stratification model, this study aims to investigate advantages of applying a machine learning approach embedded with a locally preserving projection (LPP) based feature combination and regeneration algorithm to predict short-term breast cancer risk. A dataset involving negative mammograms acquired from 500 women was assembled. This dataset was divided into two age-matched classes of 250 high risk cases in which cancer was detected in the next subsequent mammography screening and 250 low risk cases, which remained negative. First, a computer-aided image processing scheme was applied to segment fibro-glandular tissue depicted on mammograms and initially compute 44 features related to the bilateral asymmetry of mammographic tissue density distribution between left and right breasts. Next, a multi-feature fusion based machine learning classifier was built to predict the risk of cancer detection in the next mammography screening. A leave-one-case-out (LOCO) cross-validation method was applied to train and test the machine learning classifier embedded with a LLP algorithm, which generated a new operational vector with 4 features using a maximal variance approach in each LOCO process. Results showed a 9.7% increase in risk prediction accuracy when using this LPP-embedded machine learning approach. An increased trend of adjusted odds ratios was also detected in which odds ratios increased from 1.0 to 11.2. This study demonstrated that applying the LPP algorithm effectively reduced feature dimensionality, and yielded higher and potentially more robust performance in predicting short-term breast cancer risk.
Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A
2017-02-01
Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p < 0.01). Five patients had a false negative ultrasonographic examination, withal of whom were diagnosed with DCIS detected by mammography. This study demonstrates the superior sensitivity of ultrasound for breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.
NASA Astrophysics Data System (ADS)
Zhang, Jun; Cain, Elizabeth Hope; Saha, Ashirbani; Zhu, Zhe; Mazurowski, Maciej A.
2018-02-01
Breast mass detection in mammography and digital breast tomosynthesis (DBT) is an essential step in computerized breast cancer analysis. Deep learning-based methods incorporate feature extraction and model learning into a unified framework and have achieved impressive performance in various medical applications (e.g., disease diagnosis, tumor detection, and landmark detection). However, these methods require large-scale accurately annotated data. Unfortunately, it is challenging to get precise annotations of breast masses. To address this issue, we propose a fully convolutional network (FCN) based heatmap regression method for breast mass detection, using only weakly annotated mass regions in mammography images. Specifically, we first generate heat maps of masses based on human-annotated rough regions for breast masses. We then develop an FCN model for end-to-end heatmap regression with an F-score loss function, where the mammography images are regarded as the input and heatmaps for breast masses are used as the output. Finally, the probability map of mass locations can be estimated with the trained model. Experimental results on a mammography dataset with 439 subjects demonstrate the effectiveness of our method. Furthermore, we evaluate whether we can use mammography data to improve detection models for DBT, since mammography shares similar structure with tomosynthesis. We propose a transfer learning strategy by fine-tuning the learned FCN model from mammography images. We test this approach on a small tomosynthesis dataset with only 40 subjects, and we show an improvement in the detection performance as compared to training the model from scratch.
The Future of Mammography: Radiology Residents’ Experiences, Attitudes, and Opinions
Baxi, Shrujal S.; Snow, Jacqueline G.; Liberman, Laura; Elkin, Elena B.
2011-01-01
OBJECTIVE The objective of our study was to assess the experiences and preferences of radiology residents with respect to breast imaging. MATERIALS AND METHODS We surveyed radiology residents at 26 programs in New York and New Jersey. Survey topics included plans for subspecialty training, beliefs, and attitudes toward breast imaging and breast cancer screening and the likelihood of interpreting mammography in the future. RESULTS Three hundred forty-four residents completed the survey (response rate, 62%). The length of time spent training in breast imaging varied from no dedicated time (37%) to 1–8 weeks (40%) to more than 9 weeks (23%). Most respondents (97%) agreed that mammography is important to women’s health. More than 85% of residents believed that mammography should be interpreted by breast imaging specialists. Respondents shared negative views about mammography, agreeing with statements that the field was associated with a high risk of malpractice (99%), stress (94%), and low reimbursement (68%). Respondents endorsed several positive attributes of mammography, including job availability (97%), flexible work schedules (94%), and few calls or emergencies (93%). Most radiology residents (93%) said that they were likely to pursue subspecialty training, and 7% expressed interest in breast imaging fellowships. CONCLUSION Radiology residents’ negative and positive views about mammography seem to be independent of time spent training in mammography and of future plans to pursue fellowship training in breast imaging. Systematic assessment of the plans and preferences of radiology residents can facilitate the development of strategies to attract trainees to careers in breast imaging. PMID:20489113
REPEAT MAMMOGRAPHY SCREENING AMONG UNMARRIED WOMEN WITH AND WITHOUT A DISABILITY
Clark, Melissa A.; Rogers, Michelle L.; Wen, Xiaozhong; Wilcox, Victoria; McCarthy-Barnett, Kate; Panarace, Jeanne; Manning, Carol; Allen, Susan; Rakowski, William
2009-01-01
Objectives Unmarried women with disabilities may be a particularly vulnerable group for underutilization of repeat mammography screening. Our goal was to compare the breast cancer screening experiences of unmarried women with disabilities (WWD) versus women with no disabilities (WND), and determine whether these experiences are associated with adherence to repeat screening. Methods We conducted a matched cohort study of 93 WWD and 93 WND to compare mammography experiences by disability status, examine rates of repeat mammography by disability status, and identify factors that are associated with repeat mammography. Results WWD were less likely to be on-schedule than WND in univariable (54.8% vs. 71.0%; relative risk = 0.77, 95% CL = 0.61, 0.97), but not multivariable, analyses. In multivariable analyses, there was a significant interaction between disability status and positive experiences as the reasons for returning to the same mammography facility. Among WND, repeat screening ranged from 59% to 86%, depending on the number of positive experiences endorsed (range=1–5). In contrast, among WWD, screening rates were only 37% among those who did not report any positive experiences and increased to a maximum of 60% regardless of whether women endorsed one to four or all five positive experiences. Severity and type of disability were not associated with repeat screening. Conclusions WWD may be less likely than WND to remain on-schedule for mammography. WWD who do not report any positive experiences as reasons for returning to a mammography facility may be at particularly high risk of underutilization of screening. PMID:19775912
Nekhlyudov, Larissa; Li, Rong; Fletcher, Suzanne W
2008-12-01
Informed decision making regarding screening mammography is recommended for women under age 50. To what extent it occurs in clinical settings is unclear. Using a mailed instrument, we surveyed women aged 40-44 prior to their first screening mammogram. All women were members of a large health maintenance organization and received care at a large medical practice in the Greater Boston area. The survey measured informed decision making, decisional conflict, satisfaction, and screening mammography knowledge and intentions to undergo screening. Ninety-six women responded to the survey (response rate 47%). Overall, women reported limited informed decision making regarding screening mammography, both with respect to information exchange and involvement in the decision process. Less than half (47%) reported discussing the benefits of screening; 23% the uncertainties; and only 7% the harms. About 30% reported discussing the nature of the decision or clinical issue; and 29% reported their provider elicited their preferred role in the decision; 38% their preferences; and 24% their understanding of the information. Women who were uninformed had higher decisional conflict (2.37 vs. 1.83, P=0.005) about screening mammography and were more likely to be dissatisfied with the information and involvement. Women's screening mammography knowledge was limited in most areas; however being presented with information did not diminish their intentions to undergo screening. Informed decision making before initiating screening mammography is limited in this setting. There appears to be little indication that information about the benefits and harms decreases women's intentions to undergo screening. Methods to communicate information to women before initiating screening mammography are needed.
Value of mammography and breast ultrasound in male patients with nipple discharge.
Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor
2013-03-01
To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Exploring a new bilateral focal density asymmetry based image marker to predict breast cancer risk
NASA Astrophysics Data System (ADS)
Aghaei, Faranak; Mirniaharikandehei, Seyedehnafiseh; Hollingsworth, Alan B.; Wang, Yunzhi; Qiu, Yuchen; Liu, Hong; Zheng, Bin
2017-03-01
Although breast density has been widely considered an important breast cancer risk factor, it is not very effective to predict risk of developing breast cancer in a short-term or harboring cancer in mammograms. Based on our recent studies to build short-term breast cancer risk stratification models based on bilateral mammographic density asymmetry, we in this study explored a new quantitative image marker based on bilateral focal density asymmetry to predict the risk of harboring cancers in mammograms. For this purpose, we assembled a testing dataset involving 100 positive and 100 negative cases. In each of positive case, no any solid masses are visible on mammograms. We developed a computer-aided detection (CAD) scheme to automatically detect focal dense regions depicting on two bilateral mammograms of left and right breasts. CAD selects one focal dense region with the maximum size on each image and computes its asymmetrical ratio. We used this focal density asymmetry as a new imaging marker to divide testing cases into two groups of higher and lower focal density asymmetry. The first group included 70 cases in which 62.9% are positive, while the second group included 130 cases in which 43.1% are positive. The odds ratio is 2.24. As a result, this preliminary study supported the feasibility of applying a new focal density asymmetry based imaging marker to predict the risk of having mammography-occult cancers. The goal is to assist radiologists more effectively and accurately detect early subtle cancers using mammography and/or other adjunctive imaging modalities in the future.
Adapting a Cancer Literacy Measure for Use among Navajo Women
Yost, Kathleen J.; Bauer, Mark C.; Buki, Lydia P.; Austin-Garrison, Martha; Garcia, Linda V.; Hughes, Christine A.; Patten, Christi A.
2016-01-01
Purpose The authors designed a community-based participatory research study to develop and test a family-based behavioral intervention to improve cancer literacy and promote mammography among Navajo women. Methods Using data from focus groups and discussions with a community advisory committee, they adapted an existing questionnaire to assess cancer knowledge, barriers to mammography, and cancer beliefs for use among Navajo women. Questions measuring health literacy, numeracy, self-efficacy, cancer communication, and family support were also adapted. Results The resulting questionnaire was found to have good content validity, and to be culturally and linguistically appropriate for use among Navajo women. Conclusions It is important to consider culture and not just language when adapting existing measures for use with AI/AN populations. English-language versions of existing literacy measures may not be culturally appropriate for AI/AN populations, which could lead to a lack of semantic, technical, idiomatic, and conceptual equivalence, resulting in misinterpretation of study outcomes. PMID:26879319
Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.
2013-01-01
This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was lower than diagnostic mammography, the median MGD from dedicated breast CT was approximately 13.5% higher than that from diagnostic mammography. The MGD for breast CT is based on a 1.45 mm skin layer and that for diagnostic mammography is based on a 4 mm skin layer; thus, favoring a lower estimate for MGD from diagnostic mammography. The median MGD from dedicated breast CT corresponds to the median MGD from 4 to 5 diagnostic mammography views. In comparison, for the same 133 breasts, the mean and the median number of views per breast during diagnostic mammography were 4.53 and 4, respectively. Paired analysis showed that there was approximately equal likelihood of receiving lower MGD from either breast CT or diagnostic mammography. Future work will investigate methods to reduce and optimize radiation dose from dedicated breast CT. PMID:24165162
Validation of no-reference image quality index for the assessment of digital mammographic images
NASA Astrophysics Data System (ADS)
de Oliveira, Helder C. R.; Barufaldi, Bruno; Borges, Lucas R.; Gabarda, Salvador; Bakic, Predrag R.; Maidment, Andrew D. A.; Schiabel, Homero; Vieira, Marcelo A. C.
2016-03-01
To ensure optimal clinical performance of digital mammography, it is necessary to obtain images with high spatial resolution and low noise, keeping radiation exposure as low as possible. These requirements directly affect the interpretation of radiologists. The quality of a digital image should be assessed using objective measurements. In general, these methods measure the similarity between a degraded image and an ideal image without degradation (ground-truth), used as a reference. These methods are called Full-Reference Image Quality Assessment (FR-IQA). However, for digital mammography, an image without degradation is not available in clinical practice; thus, an objective method to assess the quality of mammograms must be performed without reference. The purpose of this study is to present a Normalized Anisotropic Quality Index (NAQI), based on the Rényi entropy in the pseudo-Wigner domain, to assess mammography images in terms of spatial resolution and noise without any reference. The method was validated using synthetic images acquired through an anthropomorphic breast software phantom, and the clinical exposures on anthropomorphic breast physical phantoms and patient's mammograms. The results reported by this noreference index follow the same behavior as other well-established full-reference metrics, e.g., the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). Reductions of 50% on the radiation dose in phantom images were translated as a decrease of 4dB on the PSNR, 25% on the SSIM and 33% on the NAQI, evidencing that the proposed metric is sensitive to the noise resulted from dose reduction. The clinical results showed that images reduced to 53% and 30% of the standard radiation dose reported reductions of 15% and 25% on the NAQI, respectively. Thus, this index may be used in clinical practice as an image quality indicator to improve the quality assurance programs in mammography; hence, the proposed method reduces the subjectivity inter-observers in the reporting of image quality assessment.
X-ray light valve (XLV): a novel detectors' technology for digital mammography
NASA Astrophysics Data System (ADS)
Marcovici, Sorin; Sukhovatkin, Vlad; Oakham, Peter
2014-03-01
A novel method, based on X-ray Light Valve (XLV) technology, is proposed for making good image quality yet inexpensive flat panel detectors for digital mammography. The digital mammography markets, particularly in the developing countries, demand quality machines at substantially lower prices than the ones available today. Continuous pressure is applied on x-ray detectors' manufacturers to reduce the flat panel detectors' prices. XLV presents a unique opportunity to achieve the needed price - performance characteristics for direct conversion, x-ray detectors. The XLV based detectors combine the proven, superior, spatial resolution of a-Se with the simplicity and low cost of liquid crystals and optical scanning. The x-ray quanta absorbed by a 200 μm a-Se produce electron - hole pairs that move under an electric field to the top and bottom of a-Se layer. This 2D charge distribution creates at the interface with the liquid crystals a continuous (analog) charge image corresponding to the impinging radiation's information. Under the influence of local electrical charges next to them, the liquid crystals twist proportionally to the charges and vary their light reflectivity. A scanning light source illuminates the liquid crystals while an associated, pixilated photo-detector, having a 42 μm pixel size, captures the light reflected by the liquid crystals and converts it in16 bit words that are transmitted to the machine for image processing and display. The paper will describe a novel XLV, 25 cm x 30 cm, flat panel detector structure and its underlying physics as well as its preliminary performance measured on several engineering prototypes. In particular, the paper will present the results of measuring XLV detectors' DQE, MTF, dynamic range, low contrast resolution and dynamic behavior. Finally, the paper will introduce the new, low cost, XLV detector based, digital mammography machine under development at XLV Diagnostics Inc.
Mammography and Other Screening Tests for Breast Problems
... in eight women will develop breast cancer by age 75 years. Regular breast screening can help find cancer at an early and more curable stage. Screening also can find problems in the breasts that are not cancer. What is mammography? Mammography is the primary tool used to screen for breast cancer and ...
Trimodel Mammography with Perfect Coregistration
2017-02-01
background, the major confounding factor in reading mammography; the imaging characteristics suggest that this contrast mechanism would be preferable...image with enhanced edges and reduced anatomical background, the major confounding factor in reading mammography; the imaging characteristics suggest...subjects, vertebrate animals , biohazards, and/or select agents Describe significant deviations, unexpected outcomes, or changes in approved protocols
Screening Mammography Utilization in Tennessee Women: The Association with Residence
ERIC Educational Resources Information Center
Brown, Kathleen C.; Fitzhugh, Eugene C.; Neutens, James J.; Klein, Diane A.
2009-01-01
Context: Approximately 70% of US women over age 40 report mammography screening within 2 years. However, rates are likely to vary by age, income, educational level, and residence. Purpose: To describe the prevalence of screening mammography and associated factors in women living in rural and urban areas of Tennessee. Methods: Using pooled data…
Attitudes and Beliefs Associated with Mammography in a Multiethnic Population in Israel
ERIC Educational Resources Information Center
Baron-Epel, Orna
2010-01-01
This article highlights beliefs, attitudes, and barriers that are associated with mammography use in four distinct cultural and ethnic groups in Israel: veteran, ultra-orthodox, and immigrant Jewish and Arab women. A random telephone survey of 1,550 women was performed. Information from claims records concerning mammography use was obtained for…
Cultural Views, Language Ability, and Mammography Use in Chinese American Women
ERIC Educational Resources Information Center
Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S.
2009-01-01
Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a…
Beyond Mammography: New Frontiers in Breast Cancer Screening
Drukteinis, Jennifer S.; Mooney, Blaise P.; Flowers, Chris I.; Gatenby, Robert A
2014-01-01
Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography has also undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including; low dose mammography; contrast enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging and MRI. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual’s age, risk, and breast density. PMID:23561631
As mammography use increases, are some providers omitting clinical breast examination?
Burns, R B; Freund, K M; Ash, A S; Shwartz, M; Antab, L; Hall, R
1996-04-08
To explore use of clinical breast examination (CBE) among women receiving mammography. A retrospective cohort analysis of 100 women aged 50 years or older with at least one bilateral mammogram. Chart review documented demographic information, severity of illness, and performance of CBE (from 1 year prior to 18 months after the mammogram). The mean age of the 100 women was 63 years. They were predominantly unmarried (60%), nonwhite (58%), and not currently employed (57%). Three quarters (76%) had mammography and CBE (comprehensive screening), while the remaining 24% had mammography only. Sociodemographic factors did not differ for women with and without comprehensive screening (P>.1). However, patients of female providers were more likely to receive comprehensive screening than patients of male providers. Specifically, 95% of women seen by female attending physicians or fellows had comprehensive screening vs 67% for male attending physicians or fellows and 61% for residents (P=.008). Mammography may be replacing CBE especially among patients of male providers. Interventions targeted to these providers could help improve the use of CBE and mammography.
Heydari, Esmat; Noroozi, Azita
2015-01-01
Breast cancer is the most common cancer in women. One way to decrease the burden of this cancer is early detection through mammography. This study compared the effectiveness of two different educational methods for teachers' uptake of mammography based on the Health Belief Model. The current study was a randomised trial of 120 teachers over 40 years old in two groups receiving multimedia or group education, both based on the Health Belief Model. Participants completed questionnaires before, immediately and three months after educational intervention. Mammography was evaluated before and after educational intervention. The participants in the two groups were demographically similar. Comparison showed no difference noted in the scores of knowledge, perceived barriers, susceptibility, and severity constructs between two groups (p > 0.05). Health motivation and benefit were perceived to be higher in the group education compared to the multimedia group. There was a significant difference in mammography between two groups after the intervention (p= 0.003). Planning and implementation of educational program based on the Health Belief Model can raise knowledge and increase participation in mammography especially with group education.
Ghahramanian, Akram; Rahmani, Azad; Aghazadeh, Ahmad Mirza; Mehr, Lida Emami
2016-01-01
Fear and fatalism have been proposed as factors affecting breast cancer screening, but the evidence is not strong. This study aimed to determine relationships of fear and fatalism with breast cancer screening behavior among Tabriz women in Iran. In a cross- sectional study, 370 women referred to 12 health centers in Tabriz were selected with two-stage cluster sampling and data regarding breast cancer screening, fatalism and fear of breast cancer were collected respectively with a checklist for screening performance, Champions Fear and Pow Fatalism Questionnaires. Data were analyzed by logistic regression with SPSS software version 16. Only 43% and 23% of participants had undergone breast self- examination and clinical breast examination. Among women older than 40 years, 38.2% had mammography history and only 2.7% of them had done it annually. Although fatalism and fear had a stimulating effects on breast cancer screening performance th relationships were not signi cant (P>0.05). There was a negative significant correlation between fear and fatalism (r= -0.24, p=0.000). On logistic regression analysis, age (OR=1.037, p<0.01) and income status (OR= 0.411, p<0.05) significantly explained BSE and age (OR=1.051, p<0.01) and body mass index (OR= 0.879, p<0.01) explained CBE. Also BMI (OR= 0.074, p<0.05) and income status (OR=0.155, p<0.01) was significantly effective for mammography following. Breast cancer screening behavior is inappropriate and affected by family livelihood status and lifestyle leads to weight gain, so that for promoting of screening behavior, economic support to families, lifestyle modification and public education are suggested.
Enewold, Lindsey; McGlynn, Katherine A; Zahm, Shelia H; Jatoi, Ismail; Anderson, William F; Gill, Abegail A; Shriver, Craig D; Zhu, Kangmin
2013-10-01
Annual surveillance mammography is recommended after a diagnosis of breast cancer. Previous studies have suggested that surveillance mammography varies by demographics and initial tumor characteristics, which are related to an individual's access to health care. The Military Health System of the Department of Defense provides beneficiaries with equal access health care and thus offers an excellent opportunity to assess whether racial differences in surveillance mammography persist when access to care is equal. Among female beneficiaries with a history of breast cancer, logistic regression was used to assess racial/ethnic variations in the use of surveillance mammography during 3 periods of 12 months each, beginning 1 year after diagnosis adjusting for demographic, tumor, and health characteristics. The rate of overall surveillance mammography decreased from 70% during the first year to 59% during the third year (P < .01). Although there was an overall tendency for surveillance mammography to be higher among minority women compared with non-Hispanic white women, after adjusting for covariates, the difference was found to be significant only during the first year among black women (odds ratio [OR], 1.46; 95% confidence interval [95% CI], 1.10-1.95) and the second year among Asian/Pacific Islander (OR, 2.29; 95%CI, 1.52-3.44) and Hispanic (OR, 1.92; 95%CI, 1.17-3.18) women. When stratified by age at diagnosis and type of breast cancer surgery performed, significant racial differences tended to be observed among younger women (aged < 50 years) and only among women who had undergone mastectomies. Minority women were equally or more likely than non-Hispanic white women to receive surveillance mammography within the Military Health System. The racial disparities in surveillance mammography reported in other studies were not observed in a system with equal access to health care. Copyright © 2013 American Cancer Society.
Factors influencing elderly women's mammography screening decisions: implications for counseling.
Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R
2007-11-16
Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65-79. Telephone surveys of 107 women aged 80+ and 93 women aged 65-79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate). The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3%) had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65-79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65-79). While a doctor's recommendation is the most important factor influencing elderly women's mammography screening decisions, habit and reassurance also strongly influence decision-making. Interventions aimed at improving clinician counseling about mammography, which include discussions around habit and reassurance, may result in better decision-making.
Comparison Between Digital and Synthetic 2D Mammograms in Breast Density Interpretation.
Alshafeiy, Taghreed I; Wadih, Antoine; Nicholson, Brandi T; Rochman, Carrie M; Peppard, Heather R; Patrie, James T; Harvey, Jennifer A
2017-07-01
The purpose of this study was to compare assessments of breast density on synthetic 2D images as compared with digital 2D mammograms. This retrospective study included consecutive women undergoing screening with digital 2D mammography and tomosynthesis during May 2015 with a negative or benign outcome. In separate reading sessions, three radiologists with 5-25 years of clinical experience and 1 year of experience with synthetic 2D mammography read digital 2D and synthetic 2D images and assigned breast density categories according to the 5th edition of BI-RADS. Inter- and intrareader agreement was assessed for each BI-RADS density assessment and combined dense and nondense categories using percent agreement and Cohen kappa coefficient for consensus and all reads. A total of 309 patients met study inclusion criteria. Agreement between consensus BI-RADS density categories assigned for digital and synthetic 2D mammography was 80.3% (95% CI, 75.4-84.5%) with κ = 0.73 (95% CI, 0.66-0.79). For combined dense and nondense categories, agreement reached 91.9% (95% CI, 88.2-94.7%). For consensus readings, similar numbers of patients were shifted between nondense and dense categories (11 and 14, respectively) with the synthetic 2D compared with digital 2D mammography. Interreader differences were apparent; assignment to dense categories was greater with digital 2D mammography for reader 1 (odds ratio [OR], 1.26; p = 0.002), the same for reader 2 (OR, 0.91; p = 0.262), and greater with synthetic 2D mammography for reader 3 (OR, 0.86; p = 0.033). Overall, synthetic 2D mammography is comparable with digital 2D mammography in assessment of breast density, though there is some variability by reader. Practices can readily adopt synthetic 2D mammography without concern that it will affect density assessment and subsequent recommendations for supplemental screening.
First breast cancer mammography screening program in Mexico: initial results 2005-2006.
Rodríguez-Cuevas, Sergio; Guisa-Hohenstein, Fernando; Labastida-Almendaro, Sonia
2009-01-01
Breast cancer is the most frequent malignant neoplasia worldwide. In emergent countries as Mexico, an increase has been shown in frequency and mortality, unfortunately, most cases in advanced loco-regional stages developed in young women. The success of breast screening in mortality reduction has been observed since 1995 in Western Europe and the United States, where as many as 40% mortality reduction has been achieved. Most countries guidelines recommends an annual or biannual mammography for all women >40 years of age. In 2005, FUCAM, a nonlucrative civil foundation in Mexico join with Mexico City government, initiated the first voluntary mammography screening program for women >40 years of age residing in Mexico City's Federal District. Mammographies were carried out with analogical mammographs in specially designed mobile units and were performed in the area of women's domiciles. This report includes data from the first 96,828 mammographies performed between March 2005 and December 2006. There were 1% of mammographies in Breast Imaging Reporting and Data System 0, 4, or 5 and 208 out of 949 women with abnormal mammographies (27.7%) had breast cancer, a rate of 2.1 per thousand, most of them in situ or stage I (29.4%) or stage II (42.2%) nevertheless 21% of those women with abnormal mammography did not present for further clinical and radiologic evaluation despite being personally notified at their home addresses. The breast cancer rate of Mexican women submitted to screening mammography is lower than in European or North American women. Family history of breast cancer, nulliparity, absence of breast feeding, and increasing age are factors that increase the risk of breast cancer. Most cancers were diagnosed in women's age below 60 years (68.5%) with a mean age of 53.55 corroborating previous data published. It is mandatory to sensitize and educate our population with regard to accepting to visit the Specialized Breast Centers.
Digital Mammography and Digital Breast Tomosynthesis.
Moseley, Tanya W
2016-06-01
Breast imaging technology has advanced significantly from the 1930s until the present. American women have a 1 in 8 chance of developing breast cancer. Mammography has been proven in multiple clinical trials to reduce breast cancer mortality. Although a mainstay of breast imaging and improved from film-screen mammography, digital mammography is not a perfect examination. Overlapping obscuring breast tissue limits mammographic interpretation. Breast digital tomosynthesis reduces and/or eliminates overlapping obscuring breast tissue. Although there are some disadvantages with digital breast tomosynthesis, this relatively lost-cost technology may be used effectively in the screening and diagnostic settings.
Determination of the anxiety level of women who present for mammography.
Bölükbaş, Nurgül; Erbil, Nülüfer; Kahraman, Azize Nuran
2010-01-01
This paper was to examine the role of anxiety in mammography screening. Breast cancer screening with mammography has been shown to be effective for preventing breast cancer death. However mammography screening can be harmful to women. One of the major problems is anxiety or lack of peace of mind in mammography screening. This study was conducted between November 3, 2007, and December 30, 2007, in Ordu Maternity and Childbirth Hospital. 93 women participated in the study. A 23-item questionnaire and the 20-item State Anxiety Inventory, developed by Spielberger et al. were completed by the participants. All numerical values were given as average ± standard deviation; p<0.05 was accepted for level of significance. The average age of the participants was 47.83 ± 7.50, the average age at marriage was 20.03 ± 4.18, the average birth number 2.91 ± 1.21, and the average age at menopause was 46.10 ± 4.70. The average anxiety level was found to be 46.20 ± 4.9. Significant differences (p<0.05) were found between education level, age at marriage, status of doing breast self examination, status of having a mammography for a breast-related complaint, and the number of mammograms done. It was determined that women who had mammography had a moderate level of anxiety.
Khan-Gates, Jenna A.; Ersek, Jennifer L.; Eberth, Jan M.; Adams, Swann A.; Pruitt, Sandi
2016-01-01
Introduction A review was conducted to summarize the current evidence and gaps in the literature on geographic access to mammography and its relationship to breast cancer-related outcomes. Methods Ovid Medline and PubMed were searched for articles published between January 1, 2000 and April 1, 2013 using Medical Subject Headings and key terms representing geographic accessibility and breast cancer-related outcomes. Due to a paucity of breast cancer treatment and mortality outcomes meeting the criteria (N=6), outcomes were restricted to breast cancer screening and stage at diagnosis. Studies included one or more of the following types of geographic accessibility measures: capacity, density, distance and travel time. Study findings were grouped by outcome and type of geographic measure. Results Twenty-one articles met inclusion criteria. Fourteen articles included stage at diagnosis as an outcome, five included mammography utilization, and two included both. Geographic measures of mammography accessibility varied widely across studies. Findings also varied, but most articles found either increased geographic access to mammography associated with increased utilization and decreased late-stage at diagnosis or no statistically significant association. Conclusion The gaps and methodologic heterogeneity in the literature to date limit definitive conclusions about an underlying association between geographic mammography access and breast cancer-related outcomes. Future studies should focus on the development and application of more precise and consistent measures of geographic access to mammography. PMID:26219677
Priming cases disturb visual search patterns in screening mammography
NASA Astrophysics Data System (ADS)
Lewis, Sarah J.; Reed, Warren M.; Tan, Alvin N. K.; Brennan, Patrick C.; Lee, Warwick; Mello-Thoms, Claudia
2015-03-01
Rationale and Objectives: To investigate the effect of inserting obvious cancers into a screening set of mammograms on the visual search of radiologists. Previous research presents conflicting evidence as to the impact of priming in scenarios where prevalence is naturally low, such as in screening mammography. Materials and Methods: An observer performance and eye position analysis study was performed. Four expert breast radiologists were asked to interpret two sets of 40 screening mammograms. The Control Set contained 36 normal and 4 malignant cases (located at case # 9, 14, 25 and 37). The Primed Set contained the same 34 normal and 4 malignant cases (in the same location) plus 2 "primer" malignant cases replacing 2 normal cases (located at positions #20 and 34). Primer cases were defined as lower difficulty cases containing salient malignant features inserted before cases of greater difficulty. Results: Wilcoxon Signed Rank Test indicated no significant differences in sensitivity or specificity between the two sets (P > 0.05). The fixation count in the malignant cases (#25, 37) in the Primed Set after viewing the primer cases (#20, 34) decreased significantly (Z = -2.330, P = 0.020). False-Negatives errors were mostly due to sampling in the Primed Set (75%) in contrast to in the Control Set (25%). Conclusion: The overall performance of radiologists is not affected by the inclusion of obvious cancer cases. However, changes in visual search behavior, as measured by eye-position recording, suggests visual disturbance by the inclusion of priming cases in screening mammography.
ERIC Educational Resources Information Center
Huang, Bin; Dignan, Mark; Han, Daikwon; Johnson, Owen
2009-01-01
Background: National and regional data indicate that breast cancer early detection is low in Kentucky, especially rural regions, perhaps because access to mammography services can be problematic. Objective: This study examined the distance between residences of women diagnosed with breast cancer and the nearest mammography facility, as a risk…
Gilbert, Fiona J; van den Bosch, Harrie C M; Petrillo, Antonella; Siegmann, Katja; Heverhagen, Johannes T; Panizza, Pietro; Gehl, Hans-Björn; Pediconi, Federica; Diekmann, Felix; Peng, Wei-Jun; Ma, Lin; Sardanelli, Francesco; Belli, Paolo; Corcione, Stefano; Zechmann, Christian M; Faivre-Pierret, Matthieu; Martincich, Laura
2014-05-01
To compare gadobenate dimeglumine-enhanced magnetic resonance imaging (MRI) with gadopentetate dimeglumine-enhanced MRI, mammography, and ultrasound for breast cancer detection across different malignant lesion types and across different densities of breast tissue. In all, 153 women with Breast Imaging Reporting and Data System (BI-RADS) 3–5 findings on mammography and/or ultrasound underwent identical breast MRI exams at 1.5T with gadobenate dimeglumine and gadopentetate dimeglumine. Images were evaluated by three independent blinded radiologists. Mammography, ultrasound, and combined mammography and/or ultrasound findings were available for 108, 109, and 131 women. Imaging findings were matched with histology data by a fourth, independent, blinded radiologist. Malignant lesion detection rates and diagnostic performance were compared. In all, 120, 120, and 140 confirmed malignant lesions were present in patients undergoing MRI+mammography, MRI+ultrasound, and MRI+mammography and/or ultrasound, respectively. Significantly greater cancer detection rates were noted by all three readers for comparisons of gadobenate dimeglumine-enhanced MRI with mammography (Δ15.8–17.5%; P < 0.0001), ultrasound (Δ18.3–20.0%; P < 0.0001), and mammography and/or ultrasound (Δ8.6–10.7%; P ≤ 0.0105) but not for comparisons of gadopentetate dimeglumine-enhanced MRI with conventional techniques (P > 0.05). The false-positive detection rates were lower on gadobenate dimeglumine-enhanced MRI than on conventional imaging (4.0–5.5% vs. 11.1% at mammography; 6.3–8.4% vs. 15.5% at ultrasound). Significantly improved cancer detection on MRI was noted in heterogeneously dense breast (91.2–97.3% on gadobenate dimeglumine-enhanced MRI vs. 77.2–84.9% on gadopentetate dimeglumine-enhanced MRI vs. 71.9-84.9% with conventional techniques) and for invasive cancers (93.2–96.2% for invasive ductal carcinoma [IDC] on gadobenate dimeglumine-enhanced MRI vs. 79.7–88.5% on gadopentetate dimeglumine-enhanced MRI vs. 77.0–84.4% with conventional techniques). Overall diagnostic performance for the detection of cancer was superior on gadobenate dimeglumine-enhanced MRI than on conventional imaging or gadopentetate dimeglumine-enhanced MRI. Gadobenate dimeglumine-enhanced MRI significantly improves cancer detection compared to gadopentetate dimeglumine-enhanced MRI, mammography, and ultrasound in a selected group of patients undergoing breast MRI for preoperative staging or because of inconclusive findings at conventional imaging.
Mack, Deborah S; Epstein, Mara M; Dubé, Catherine; Clark, Robin E; Lapane, Kate L
2018-06-04
United States (US) guidelines regarding when to stop routine breast cancer screening remain unclear. No national studies to-date have evaluated the use of screening mammography among US long-stay nursing home residents. This cross-sectional study was designed to identify prevalence, predictors, and geographic variation of screening mammography among that population in the context of current US guidelines. Screening mammography prevalence, identified with Physician/Supplier Part B claims and stratified by guideline age classification (65-74, ≥75 years), was estimated for all women aged ≥65 years residing in US Medicare- and Medicaid- certified nursing homes (≥1 year) with an annual Minimum Data Set (MDS) 3.0 assessment, continuous Medicare Part B enrollment, and no clinical indication for screening mammography as of 2011 (n = 389,821). The associations between resident- and regional- level factors, and screening mammography, were estimated by crude and adjusted prevalence ratios from robust Poisson regressions clustered by facility. Women on average were 85.4 (standard deviation ±8.1) years old, 77.9% were disabled, and 76.3% cognitively impaired. Screening mammography prevalence was 7.1% among those aged 65-74 years (95% Confidence Interval (CI): 6.8%-7.3%) and 1.7% among those ≥75 years (95% CI, 1.7%-1.8%), with geographic variation observed. Predictors of screening in both age groups included race, cognitive impairment, frailty, hospice, and some comorbidities. These results shed light on the current screening mammography practices in US nursing homes. Thoughtful consideration about individual screening recommendations and the implementation of more clear guidelines for this special population are warranted to prevent overscreening. Copyright © 2018 Elsevier Inc. All rights reserved.
Charlie, Abbas M; Gao, Yiming; Heller, Samantha L
2017-12-05
The purpose of this project is to identify questions and concerns patients have regarding breast cancer screening mammography to establish priorities in patient education and health care communication. A content analysis of posted questions (June 2010 to February 2017) containing the keywords mammogram and mammography was conducted on the social media question and answer website Quora (Quora Inc, Mountainview, California). Question topic, responses, and number of views were recorded. Comparisons were made by respondent type (medical professional or nonmedical professional) for screening recommendations and accompanying evidence. Descriptive statistics were employed to summarize the results. Overall, 197,620 views of mammography-related questions were identified, focused on 51 questions and 172 responses (51 of 172 [29.7%] by medical professionals [n = 25]; 121 of 172 [70.3%] by nonmedical professionals [n = 121]). Mammographic efficacy (16 of 51 [31.4%]) and screening guidelines (10 of 51 [19.6%]) were the most frequently queried topics. Overall, the majority of respondents were supportive of screening mammography. Most medical professionals recommended screening mammography starting at age 40, even after revisions in guidelines. Among nonmedical professionals, 4 of 22 (18.2%) were against screening mammography with less consensus regarding appropriate age of initial screen. Health society websites and journal articles were the most commonly referenced sources among medical and nonmedical professionals, respectively. A considerable interest in screening mammography guidelines and mammographic efficacy exists among users who seek health information on a social media question and answer website. Awareness of such platforms allows a unique opportunity for targeted health education and dissemination of accurate information, which may be able to reach a potentially untapped or hard-to-reach patient population. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D
2015-03-01
To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.
The U.S. Online News Coverage of Mammography Based on a Google News Search.
Young Lin, Leng Leng; Rosenkrantz, Andrew B
2017-12-01
To characterize online news coverage relating to mammography, including articles' stance toward screening mammography. Google News was used to search U.S. news sites over a 9-year period (2006-2015) based on the search terms "mammography" and "mammogram." The top 100 search results were recorded. Identified articles were manually reviewed. The top 100 news articles were from the following sources: local news outlet (50%), national news outlet (24%), nonimaging medical source (13%), entertainment or culture news outlet (6%), business news outlet (4%), peer-reviewed journal (1%), and radiology news outlet (1%). Most common major themes were the screening mammography controversy (29%), description of a new breast imaging technology (23%), dense breasts (11%), and promotion of a public screening initiative (11%). For the most recent year, article stance toward screening mammography was 59%, favorable; 16%, unfavorable; and 25%, neutral. After 2010, there was an abrupt shift in articles' stances from neutral to both favorable and unfavorable. A wide range of online news sources addressed a range of issues related to mammography. National, rather than local, news sites were more likely to focus on the screening controversy and more likely to take an unfavorable view. The controversial United States Preventive Services Task Force guidelines may have influenced articles to take a stance on screening mammography. As such online news may impact public perception of the topic and thus potentially impact guideline adherence, radiologists are encouraged to maintain awareness of this online coverage and to support the online dissemination of reliable and accurate information. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
‘It’s Easier Said Than Done’: Perspectives on Mammography From Women With Intellectual Disabilities
Wilkinson, Joanne E.; Deis, Cristina E.; Bowen, Deborah J.; Bokhour, Barbara G.
2011-01-01
PURPOSE Women with intellectual disabilities (or mental retardation) are living longer, receiving primary care in the community, and have equal rates of breast cancer compared with women in the general population, but they have lower rates of mammography. Although several public campaigns have successfully raised the mammography rate for racial and ethnic minority women, they have not penetrated the community of women with intellectual disabilities. No research to date has explored potential barriers to mammography for these women by involving the women themselves as participants. METHODS We undertook a qualitative study to explore the perceptions and understanding of mammography for women with intellectual disabilities and some of the potential reasons they would or would not have the test. Twenty-seven intellectually disabled women were recruited through a variety of community groups and interviewed using a semistructured interview guide. Data were analyzed using qualitative techniques from grounded theory. RESULTS Participants in this study described being poorly prepared for mammography: they did not understand its purpose and were not prepared for the logistics of the experience. The latter was more upsetting to participants and contributed to their negative perceptions of mammography. Participants reported feeling unprepared and singled out for being unprepared, despite their desire to have at least 1 mammogram, as do other women their age. CONCLUSIONS Women with intellectual disabilities perceive mammography differently than do women who do not have intellectual disabilities, and their perception is informed by inadequate knowledge, anxiety, and inadequate preparation. These themes should be considered when planning cancer prevention interventions with this population and when counseling individual women in the clinical setting. PMID:21403141
Screening Mammography and Digital Breast Tomosynthesis: Utilization Updates.
Boroumand, Gilda; Teberian, Ida; Parker, Laurence; Rao, Vijay M; Levin, David C
2018-05-01
There have been many recent developments in breast imaging, including the 2009 revision of the U.S. Preventive Services Task Force's breast cancer screening guidelines and the approval of digital breast tomosynthesis (DBT) for clinical use in 2011. The objective of this study is to evaluate screening mammography utilization trends among the Medicare population from 2005 to 2015 and examine the volume of DBT studies performed in 2015, the first year for which procedural billing codes for DBT are available. We reviewed national Medicare Part B Physician/Supplier Procedure Summary master files from 2005 to 2015, to determine the annual utilization rate of screening mammography on the basis of procedure codes used for film-screen and digital screening mammography. We also used the Physician/Supplier Procedure Summary master files to determine the volume of screening and diagnostic DBT studies performed in 2015. The utilization rate of screening mammography per 1000 women in the Medicare fee-for-service population increased gradually every year, from 311.5 examinations in 2005 to a peak of 322.9 examinations in 2009, representing a compound annual growth rate of 0.9%. In 2010, the utilization rate abruptly decreased by 4.3% to 309.2 examinations, and it has not since recovered to pre-2010 levels. In 2015, 18.9% of screening and 16.2% of diagnostic digital mammography examinations included DBT as an add-on procedure. In contrast to the annual increase in screening mammography utilization from 2005 to 2009, an abrupt sustained decline in screening occurred beginning in 2010, coinciding with the release of U.S. Preventive Services Task Force recommendations. DBT utilization was somewhat limited in 2015, occurring in conjunction with less than 20% of digital mammography examinations.
Taplin, S H; Urban, N; Taylor, V M; Savarino, J
1997-01-01
This study evaluated whether women's perceptions of the conflicting recommendations for breast cancer screening were associated with decreased use of mammography. We conducted a random-digit-dial telephone survey of 1024 women in four communities of western Washington State. In addition to collecting data for demographics, beliefs about mammography, and insurance coverage, we inquired whether the respondents were aware of any conflicting recommendations about when to begin or how frequently to perform screening mammography, whether their physicians had recommended a mammogram, and whether they were likely to do what their physicians recommended. After grouping women according to whether they perceived conflicting recommendations, we used chi-square statistics to compare the distribution of proportions of women by age, race, household income, education, and insurance coverage. To estimate the odds of their having a mammogram in the previous 2 years (yes or no), we used multivariate logistic regression and included the above variables as covariates. Sixty-two percent of eligible women completed the survey, and 49 percent (479 of 985) perceived conflicting recommendations. The association between perceiving conflict and mammography use was not significant. Eighty-three percent of women who perceived conflicting recommendations reported being more comfortable using their own judgment about getting the procedure. After controlling for whether women perceived conflicting recommendations and all other factors, women who said they followed their physician's advice but did not recall their physician recommending mammography were 71 percent less likely to have received a recent mammogram than were women who reported their physician did recommend it (odds ratio 0.29, confidence interval 0.16-0.51). The conflicting recommendations surrounding breast cancer screening are not influencing women's choices about mammography. The physician recommendation and women's self-reported likeliness to follow it are the most important factors associated with mammography use.
Factors affecting the precision of lesion sizing with contrast-enhanced spectral mammography.
Travieso-Aja, M Del Mar; Naranjo-Santana, P; Fernández-Ruiz, C; Severino-Rondón, W; Maldonado-Saluzzi, D; Rodríguez Rodríguez, M; Vega-Benítez, V; Luzardo, O P
2018-03-01
To evaluate the precision of the pre-surgical measurement of the size of breast cancer by contrast-enhanced spectral mammography (CESM). This was a retrospective study of 204 breast cancers. Variables related to tumour biology and anthropometric variables were recorded and considered when evaluating the efficacy of CESM in predicting tumour size. Microscopic measurement of the largest diameter of the tumour at pathology was chosen as the reference standard. The mean size of tumours at pathology was 20.7±15.8 mm, while at CESM it was 23.6±16.7 mm (Bland-Altman 2.9 mm overestimation, 2.9 mm; 95% confidence interval [CI]: -10.3-16.2 mm). Spearman's correlation coefficient was 0.83 (p<0.0001). The concordance analysis indicated that 37.8% of the measurements were concordant, 47% were overestimated, and 15.2% were underestimated. Tumour size, nodal involvement, breast density, and breast size significantly modified the sizing accuracy. Quality of tumour size prediction with CESM is good, and this appears to be a promising imaging technique in the surgical planning of breast cancer. Biological tumour features, and anthropological characteristics of the patients do, however, affect the diagnostic precision and should be taken into account. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Digital mammography, cancer screening: Factors important for image compression
NASA Technical Reports Server (NTRS)
Clarke, Laurence P.; Blaine, G. James; Doi, Kunio; Yaffe, Martin J.; Shtern, Faina; Brown, G. Stephen; Winfield, Daniel L.; Kallergi, Maria
1993-01-01
The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.
Breast imaging. A practical look at its capabilities and its limitations.
Clark, R; Nemec, L; Love, N
1992-10-01
The film-screen technique is evolving as the standard for mammography. Sonography is the only other method that currently has a defined role in breast imaging. Mammography should be performed at facilities that have received American College of Radiology accreditation or its equivalent, because technical quality assurance is an important part of mammographic practice. Interpretive quality may be assured by outcome audits performed by mammography facilities. Primary care physicians are best suited to encouraging eligible women to undergo screening studies and should consider these recommendations: Refer patients for screening mammography to accredited facilities according to established guidelines. Educate patients about the need for regular screening. Provide annual breast physical examination. Refresh your knowledge on breast health and the techniques of physical examination if necessary. Teach patients breast self-examination techniques. Demand low-cost, high-quality screening mammography; be aware of local variability of charges and quality.
Mammography screening services: market segments and messages.
Scammon, D L; Smith, J A; Beard, T
1991-01-01
Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.
Tomosynthesis in the Diagnostic Setting: Changing Rates of BI-RADS Final Assessment over Time.
Raghu, Madhavi; Durand, Melissa A; Andrejeva, Liva; Goehler, Alexander; Michalski, Mark H; Geisel, Jaime L; Hooley, Regina J; Horvath, Laura J; Butler, Reni; Forman, Howard P; Philpotts, Liane E
2016-10-01
Purpose To evaluate the effect of tomosynthesis in diagnostic mammography on the Breast Imaging Reporting and Data System (BI-RADS) final assessment categories over time. Materials and Methods This retrospective study was approved by the institutional review board. The authors reviewed all diagnostic mammograms obtained during a 12-month interval before (two-dimensional [2D] mammography [June 2, 2010, to June 1, 2011]) and for 3 consecutive years after (tomosynthesis year 1 [2012], tomosynthesis year 2 [2013], and tomosynthesis year 3 [2014]) the implementation of tomosynthesis. The requirement to obtain informed consent was waived. The rates of BI-RADS final assessment categories 1-5 were compared between the 2D and tomosynthesis groups. The positive predictive values after biopsy (PPV3) for BI-RADS category 4 and 5 cases were compared. The mammographic features (masses, architectural distortions, calcifications, focal asymmetries) of lesions categorized as probably benign (BI-RADS category 3) and those for which biopsy was recommended (BI-RADS category 4 or 5) were reviewed. The χ(2) test was used to compare the rates of BI-RADS final assessment categories 1-5 between the two groups, and multivariate logistic regression analysis was performed to compare all diagnostic studies categorized as BI-RADS 3-5. Results There was an increase in the percentage of cases reported as negative or benign (BI-RADS category 1 or 2) with tomosynthesis (58.7% with 2D mammography vs 75.8% with tomosynthesis at year 3, P < .0001). A reduction in the percentage of probably benign (BI-RADS category 3) final assessments also occurred (33.3% with 2D mammography vs 16.4% with tomosynthesis at year 3, P < .0001). Although the rates of BI-RADS 4 or 5 assessments did not change significantly with tomosynthesis (8.0% with 2D mammography vs 7.8% with tomosynthesis at year 3, P = .2), there was a significant increase in the PPV3 (29.6% vs 50%, respectively; P < .0001). These trends increased during the 3 years of tomosynthesis use. Conclusion Tomosynthesis in the diagnostic setting resulted in progressive shifts in the BI-RADS final assessment categories over time, with a significant increase in the proportion of studies classified as normal, a continued decrease in the rate of studies categorized as probably benign, and improved diagnostic confidence in biopsy recommendations. (©) RSNA, 2016.
Ding, Huanjun; Molloi, Sabee
2017-08-01
To investigate the feasibility of accurate quantification of iodine mass thickness in contrast-enhanced spectral mammography. A computer simulation model was developed to evaluate the performance of a photon-counting spectral mammography system in the application of contrast-enhanced spectral mammography. A figure-of-merit (FOM), which was defined as the decomposed iodine signal-to-noise ratio (SNR) with respect to the square root of the mean glandular dose (MGD), was chosen to optimize the imaging parameters, in terms of beam energy, splitting energy, and prefiltrations for breasts of various thicknesses and densities. Experimental phantom studies were also performed using a beam energy of 40 kVp and a splitting energy of 34 keV with 3 mm Al prefiltration. A two-step calibration method was investigated to quantify the iodine mass thickness, and was validated using phantoms composed of a mixture of glandular and adipose materials, for various breast thicknesses and densities. Finally, the traditional dual-energy log-weighted subtraction method was also studied as a comparison. The measured iodine signal from both methods was compared to the known value to characterize the quantification accuracy and precision. The optimal imaging parameters, which lead to the highest FOM, were found at a beam energy between 42 and 46 kVp with a splitting energy at 34 keV. The optimal tube voltage decreased as the breast thickness or the Al prefiltration increased. The proposed quantification method was able to measure iodine mass thickness on phantoms of various thicknesses and densities with high accuracy. The root-mean-square (RMS) error for cm-scale lesion phantoms was estimated to be 0.20 mg/cm 2 . The precision of the technique, characterized by the standard deviation of the measurements, was estimated to be 0.18 mg/cm 2 . The traditional weighted subtraction method also predicted a linear correlation between the measured signal and the known iodine mass thickness. However, the correlation slope and offset values were strongly dependent on the total breast thickness and density. The results of this study suggest that iodine mass thickness for cm-scale lesions can be accurately quantified with contrast-enhanced spectral mammography. The quantitative information can potentially improve the differential power for malignancy. © 2017 American Association of Physicists in Medicine.
Coldman, Andrew; Phillips, Norm
2013-07-09
There has been growing interest in the overdiagnosis of breast cancer as a result of mammography screening. We report incidence rates in British Columbia before and after the initiation of population screening and provide estimates of overdiagnosis. We obtained the numbers of breast cancer diagnoses from the BC Cancer Registry and screening histories from the Screening Mammography Program of BC for women aged 30-89 years between 1970 and 2009. We calculated age-specific rates of invasive breast cancer and ductal carcinoma in situ. We compared these rates by age, calendar period and screening participation. We obtained 2 estimates of overdiagnosis from cumulative cancer rates among women between the ages of 40 and 89 years: the first estimate compared participants with nonparticipants; the second estimate compared observed and predicted population rates. We calculated participation-based estimates of overdiagnosis to be 5.4% for invasive disease alone and 17.3% when ductal carcinoma in situ was included. The corresponding population-based estimates were -0.7% and 6.7%. Participants had higher rates of invasive cancer and ductal carcinoma in situ than nonparticipants but lower rates after screening stopped. Population incidence rates for invasive cancer increased after 1980; by 2009, they had returned to levels similar to those of the 1970s among women under 60 years of age but remained elevated among women 60-79 years old. Rates of ductal carcinoma in situ increased in all age groups. The extent of overdiagnosis of invasive cancer in our study population was modest and primarily occurred among women over the age of 60 years. However, overdiagnosis of ductal carcinoma in situ was elevated for all age groups. The estimation of overdiagnosis from observational data is complex and subject to many influences. The use of mammography screening in older women has an increased risk of overdiagnosis, which should be considered in screening decisions.
Herrada, J; Iyer, R B; Atkinson, E N; Sneige, N; Buzdar, A U; Hortobagyi, G N
1997-09-01
The purpose of this study was to correlate physical examination and sonographic and mammographic measurements of breast tumors and regional lymph nodes with pathological findings and to evaluate the effect of neoadjuvant chemotherapy on clinical Tumor-Node-Metastasis stage by noninvasive methods. This was a retrospective analysis of 100 patients with locally advanced breast cancer registered and treated in prospective trials of neoadjuvant chemotherapy. All patients received four cycles of a doxorubicin-containing regimen and had noninvasive evaluation of the primary tumor and regional lymph nodes before and after neoadjuvant chemotherapy by physical examination, sonography, and mammography and underwent breast surgery and axillary dissection within 5 weeks after completion of neoadjuvant chemotherapy. The correlations between clinical and pathological measurements were determined by Spearman rank correlation analysis. A proportional odds model was used to examine predictive values. Eighty-three patients had both a clinically detectable primary tumor and lymph node metastases. Sixty-four patients had a decrease in Tumor-Node-Metastasis stage after chemotherapy. For 54% of patients, there was concordance in clinical response between the primary tumor and lymph node compartment; for the rest, results were discordant. Physical examination correlated best with pathological findings in the measurement of the primary tumor (P = 0.0003), whereas sonography was the most accurate predictor of size for axillary lymph nodes (P = 0.0005). The combination of physical examination and mammography worked best for assessment of the primary tumor (P = 0.003), whereas combining physical examination with sonography gave optimal evaluation of regional lymph nodes (P = 0.0001). In conclusion, physical examination is the best noninvasive predictor of the real size of locally advanced primary breast cancer, whereas sonography correlates better with the real dimensions of axillary lymph nodes. The combination of physical examination with either mammography or sonography significantly improves the accuracy of noninvasive assessment of tumor dimensions.
Van Uytven, Eric; Pistorius, Stephen; Gordon, Richard
2007-01-01
X-ray film-screen mammography is currently the gold standard for detecting breast cancer. However, one disadvantage is that it projects a three-dimensional (3D) object onto a two-dimensional (2D) image, reducing contrast between small lesions and layers of normal tissue. Another limitation is its reduced sensitivity in women with mammographically dense breasts. Computed tomography (CT) produces a 3D image yet has had a limited role in mammography due to its relatively high dose, low resolution, and low contrast. As a first step towards implementing quantitative 3D mammography, which may improve the ability to detect and specify breast tumors, we have developed an analytical technique that can use Compton scatter to obtain 3D information of an object from a single projection. Imaging material with a pencil beam of polychromatic x rays produces a characteristic scattered photon spectrum at each point on the detector plane. A comparable distribution may be calculated using a known incident x-ray energy spectrum, beam shape, and an initial estimate of the object's 3D mass attenuation and electron density. Our iterative minimization algorithm changes the initially arbitrary electron density voxel matrix to reduce regular differences between the analytically predicted and experimentally measured spectra at each point on the detector plane. The simulated electron density converges to that of the object as the differences are minimized. The reconstruction algorithm has been validated using simulated data produced by the EGSnrc Monte Carlo code system. We applied the imaging algorithm to a cylindrically symmetric breast tissue phantom containing multiple inhomogeneities. A preliminary ROC analysis scores greater than 0.96, which indicate that under the described simplifying conditions, this approach shows promise in identifying and localizing inhomogeneities which simulate 0.5 mm calcifications with an image voxel resolution of 0.25 cm and at a dose comparable to mammography.
A multi-image approach to CADx of breast cancer with integration into PACS
NASA Astrophysics Data System (ADS)
Elter, Matthias; Wittenberg, Thomas; Schulz-Wendtland, Rüdiger; Deserno, Thomas M.
2009-02-01
While screening mammography is accepted as the most adequate technique for the early detection of breast cancer, its low positive predictive value leads to many breast biopsies performed on benign lesions. Therefore, we have previously developed a knowledge-based system for computer-aided diagnosis (CADx) of mammographic lesions. It supports the radiologist in the discrimination of benign and malignant lesions. So far, our approach operates on the lesion level and employs the paradigm of content-based image retrieval (CBIR). Similar lesions with known diagnosis are retrieved automatically from a library of references. However, radiologists base their diagnostic decisions on additional resources, such as related mammographic projections, other modalities (e.g. ultrasound, MRI), and clinical data. Nonetheless, most CADx systems disregard the relation between the craniocaudal (CC) and mediolateral-oblique (MLO) views of conventional mammography. Therefore, we extend our approach to the full case level: (i) Multi-frame features are developed that jointly describe a lesion in different views of mammography. Taking into account the geometric relation between different images, these features can also be extracted from multi-modal data; (ii) the CADx system architecture is extended appropriately; (iii) the CADx system is integrated into the radiology information system (RIS) and the picture archiving and communication system (PACS). Here, the framework for image retrieval in medical applications (IRMA) is used to support access to the patient's health care record. Of particular interest is the application of the proposed CADx system to digital breast tomosynthesis (DBT), which has the potential to succeed digital mammography as the standard technique for breast cancer screening. The proposed system is a natural extension of CADx approaches that integrate only two modalities. However, we are still collecting a large enough database of breast lesions with images from multiple modalities to evaluate the benefits of the proposed approach on.
Breast dosimetry in clinical mammography
NASA Astrophysics Data System (ADS)
Benevides, Luis Alberto Do Rego
The objective of this study was show that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. In the study, AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The protocol proposes the use of a fiber-optic coupled (FOCD) or Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeter to measure the entrance skin exposure at the time of the mammogram without interfering with diagnostic information of the mammogram. The study showed that FOCD had sensitivity with less than 7% energy dependence, linear in all tube current-time product stations, and was reproducible within 2%. FOCD was superior to MOSFET dosimeter in sensitivity, reusability, and reproducibility. The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. In addition, the study population anthropometric measurements enabled the development of analytical equations to calculate the whole breast area, estimate for the skin layer thickness and optimal location for automatic exposure control ionization chamber. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.
Optimization of tungsten x-ray spectra for digital mammography: a comparison of model to experiment
NASA Astrophysics Data System (ADS)
Andre, Michael P.; Spivey, Brett A.
1997-05-01
Tungsten (W) target x-rays tubes are being studied for use in digital mammography to improve x-ray flux, reduce noise and increase tube heat capacity. A parametric model was developed for digital mammography to evaluate optimization of x-ray spectra for a particular sensor. The model computes spectra and mean glandular doses (MGD) for combinations of W target, beam filters, kVp, breast type and thickness. Two figures of merit were defined: (signal/noise)2/MGD and spectral quantum efficiency; these were computed as a means to approach optimization of object contrast. The model is derived from a combination of classic equations, XCOM from NBS, and published data. X-ray spectra were calculated and measured for filters of Al, Sn, Rh, Mo and Ag on a Eureka tube. (Signal/noise)2/MGD was measured for a filtered W target tube and a digital camera employing CsI scintillator optically coupled to a CCD for which the detective quantum efficiency (DQE) was known. A 3-mm thick acrylic disk was imaged on thickness of 3-8 cm of acrylic and the results were compared to the predictions of the model. The relative error between predicted and measured spectra was +/- 2 percent from 24 to 34 kVp. Calculated MGD as a function of breast thickness, half-value layer and beam filter compares very well to published data. Best performance was found for the following combinations: Mo filter with 30 mm breast, Ag filter with 45 mm, Sn filter for 60 mm, and Al filter for 75 mm thick breast. The parametric model agrees well with measurement and provides a means to explore optimum combinations of kVp and beam filter. For a particular detector, this data may be used with the DQE to estimate total system signal-to-noise ratio for a particular imaging task.
Potential Cost Savings of Contrast-Enhanced Digital Mammography.
Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A
2017-06-01
The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.
[Comparative study between film mammography and xeromammography; including specimen radiography].
Maeda, M; Hayakawa, K; Okuno, Y; Torizuka, T; Mitsumori, M; Soga, T; Misaki, T; Dokou, S; Ito, K
1990-10-01
We retrospectively evaluated preoperative film- and xeromammography of 23 cases with breast cancers, and compared with postoperative specimen radiography to assess tumor delineation and microcalcification detectability. In tumor detection and margin delineation, film mammography was superior to xeromammography, and in microcalcification, film mammography was equal to xeromammography. These results had a effect on the diagnosis of breast cancers.
Dual-energy contrast-enhanced mammography.
Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P
2014-01-01
The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.
A comparison of the performance of modern screen-film and digital mammography systems.
Monnin, P; Gutierrez, D; Bulling, S; Lepori, D; Valley, J-F; Verdun, F R
2005-06-07
This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.
Castro-Ibarra, Marisela; Menchaca-Díaz, Rufino; Cabrales-Ruvalcaba, J Jesús; Luna-V Gómez, Rosa Alicia
2016-01-01
To analyze the association between a false positive result in mammography and obesity, inside the breast cancer early detection program in women affiliated to the Institute of Security and Social Services for Government and Municipality workers of the State of Baja California (ISSSTECALI). A case-control, retrospective study was done in women affiliated to ISSSTECALI to whom a mammography was performed between 2009 and 2012. Women with a false positive result in mammography were included as cases. Controls were women with a true negative result in mammography. Three controls were randomly selected for each case. Obesity was established with the body mass index (BMI) consigned in the woman's clinical file. Age and estrogen replacement therapy were included as co-variables. Seventy nine cases were identified and 237 controls were included. Obesity was observed in 54.4% of cases and in 41.3% of controls (odds ratio: 1.69; 95% confidence interval for odds ratio: 1.01-2.82; p value: 0.043). A logistic regression model including covariables maintained the observed association (p = 0.044). No association was found with analyzed co-variables. A false positive result in mammography was associated with the presence of obesity.
Darnell, Julie S; Chang, Chih-Hung; Calhoun, Elizabeth A
2006-07-01
This article assessed the impact of knowledge of breast cancer and type and intensity of participation in a church-based breast cancer education program and other factors on mammography screening among African Americans and Latinas. Logistic regression was used to assess the impact of these factors on self-reported mammography utilization. Passive participation in church-sponsored activities, measured by breast cancer information that was heard, seen, or read, was found to be significantly associated with the likelihood of mammography use among African Americans. Moreover, African Americans who reported hearing, seeing, or reading about mammograms at their churches four or more times were 15 times more likely to report mammography use within the past year than were those who encountered information only once. Messages from pastors and church bulletin announcements were the most significant predictors. An increase in knowledge was not associated with higher mammography use. For Latinas, none of the hypothesized knowledge or participation variables was found to be significant. The results suggest that faith-based breast cancer programs can be effective by adopting tailored strategies to raise awareness about the importance of early detection.
Lai, Hsien-Tang; Kung, Pei-Tseng; Tsai, Wen-Chen
2014-12-01
Women with intellectual disabilities (ID) have cognitive impairment and communication difficulties; for both caregivers and clinical personnel, discovering the early symptoms of breast cancer among women with ID is challenging. The mammography utilization rate of women with ID was significantly lower than that of women in the general population. This study employed a 2008 database of people with disabilities in Taiwan as a research target and analyzed the mammography utilization rate of women with ID aged 50–69 years. In addition, relevant factors influencing mammography utilization among women with ID were also investigated. A total of 4370 participants were recruited and the majority were illiterate or had elementary-level educations (82.27%). The majority of the participants had ID that was more severe than mild (83.80%). The mammography utilization rate of women with ID was 4.32%, which was significantly lower than that of women in the general population (12%). The mammography utilization rate among women with ID who were married, had higher education levels, and had been diagnosed with cancer, diabetes, or mild ID was significantly higher. However, the mammography utilization rate among women with ID, who had elementary-level educations or were illiterate, was only 4.03%. The utilization rate among women with profound ID was only 2.65%. Women with ID who had undergone pap smears or had utilized adult preventive health services demonstrated a significantly higher mammography utilization rate. This study identified that education level, a diagnosis of diabetes, and the application of pap smears or adult preventive health services were primary factors that influenced the mammography utilization rate among women with ID. This study also observed that in Taiwan, the mammography utilization rate of women with ID was lower than that of pap smears and adult preventive health services, and was only half of that of people with disabilities. An unequal situation existed in regard to the acceptance of breast cancer screening among women with ID, and a different form of strategic planning must be adopted in public health policy. Because ID differs from other disabilities and most women with ID are illiterate, tailored courses are required to train primary caregivers and clinical personnel in providing knowledge and services. The objectives are to diagnose breast cancer at an early stage to decrease the risk of mortality and ensure their rights to health.
Robertson, C; Arcot Ragupathy, S K; Boachie, C; Dixon, J M; Fraser, C; Hernández, R; Heys, S; Jack, W; Kerr, G R; Lawrence, G; MacLennan, G; Maxwell, A; McGregor, J; Mowatt, G; Pinder, S; Ternent, L; Thomas, R E; Vale, L; Wilson, R; Zhu, S; Gilbert, F J
2011-09-01
Following primary breast cancer treatment, the early detection of ipsilateral breast tumour recurrence (IBTR) or ipsilateral secondary cancer in the treated breast and detection of new primary cancers in the contralateral breast is beneficial for survival. Surveillance mammography is used to detect these cancers, but the optimal frequency of surveillance and the length of follow-up are unclear. To identify feasible management strategies for surveillance and follow-up of women after treatment for primary breast cancer in a UK setting, and to determine the effectiveness and cost-effectiveness of differing regimens. A survey of UK breast surgeons and radiologists to identify current surveillance mammography regimens and inform feasible alternatives; two discrete systematic reviews of evidence published from 1990 to mid 2009 to determine (i) the clinical effectiveness and cost-effectiveness of differing surveillance mammography regimens for patient health outcomes and (ii) the test performance of surveillance mammography in the detection of IBTR and metachronous contralateral breast cancer (MCBC); statistical analysis of individual patient data (West Midlands Cancer Intelligence Unit Breast Cancer Registry and Edinburgh data sets); and economic modelling using the systematic reviews results, existing data sets, and focused searches for specific data analysis to determine the effectiveness and cost-utility of differing surveillance regimens. The majority of survey respondents initiate surveillance mammography 12 months after breast-conserving surgery (BCS) (87%) or mastectomy (79%). Annual surveillance mammography was most commonly reported for women after BCS or after mastectomy (72% and 53%, respectively). Most (74%) discharge women from surveillance mammography, most frequently 10 years after surgery. The majority (82%) discharge from clinical follow-up, most frequently at 5 years. Combining initiation, frequency and duration of surveillance mammography resulted in 54 differing surveillance regimens for women after BCS and 56 for women following mastectomy. The eight studies included in the clinical effectiveness systematic review suggest surveillance mammography offers a survival benefit compared with a surveillance regimen that does not include surveillance mammography. Nine studies were included in the test performance systematic review. For routine IBTR detection, surveillance mammography sensitivity ranged from 64% to 67% and specificity ranged from 85% to 97%. For magnetic resonance imaging (MRI), sensitivity ranged from 86% to 100% and specificity was 93%. For non-routine IBTR detection, sensitivity and specificity for surveillance mammography ranged from 50% to 83% and from 57% to 75%, respectively, and for MRI from 93% to 100% and from 88% to 96%, respectively. For routine MCBC detection, one study reported sensitivity of 67% and specificity of 50% for both surveillance mammography and MRI, although this was a highly select population. Data set analysis showed that IBTR has an adverse effect on survival. Furthermore, women experiencing a second tumour measuring >20 mm in diameter were at a significantly greater risk of death than those with no recurrence or those whose tumour was <10 mm in diameter. In the base-case analysis, the strategy with the highest net benefit, and most likely to be considered cost-effective, was surveillance mammography alone, provided every 12 months at a societal willingness to pay for a quality-adjusted life-year of either £20,000 or £30,000. The incremental cost-effectiveness ratio for surveillance mammography alone every 12 months compared with no surveillance was £4727. Few studies met the review inclusion criteria and none of the studies was a randomised controlled trial. The limited and variable nature of the data available precluded any quantitative analysis. There was no useable evidence contained in the Breast Cancer Registry database to assess the effectiveness of surveillance mammography directly. The results of the economic model should be considered exploratory and interpreted with caution given the paucity of data available to inform the economic model. Surveillance is likely to improve survival and patients should gain maximum benefit through optimal use of resources, with those women with a greater likelihood of developing IBTR or MCBC being offered more comprehensive and more frequent surveillance. Further evidence is required to make a robust and informed judgement on the effectiveness of surveillance mammography and follow-up. The utility of national data sets could be improved and there is a need for high-quality, direct head-to-head studies comparing the diagnostic accuracy of tests used in the surveillance population. The National Institute for Health Research Health Technology Assessment programme. © Queen’s Printer and Controller of HMSO 2011.
Dual-energy in mammography: feasibility study
NASA Astrophysics Data System (ADS)
Jafroudi, Hamid; Lo, Shih-Chung B.; Li, Huai; Steller Artz, Dorothy E.; Freedman, Matthew T.; Mun, Seong K.
1996-04-01
The purpose of this work is to examine the feasibility of dual-energy techniques to enhance the detection of microcalcifications in digital mammography. The digital mammography system used in this study consists of two different mammography systems; one is the conventional mammography system with molybdenum target and Mo filtration and the other is the clinical version of a low dose x-ray system with tungsten target and aluminum filtration. The low dose system is optimized for screen-film mammography with a highly efficient scatter rejection device built by Fischer Imaging Systems for evaluation at NIH. The system was designed by the University of Southern California based on multiparameter optimization techniques. Prototypes of this system have been constructed and evaluated at the Center for Devices and Radiological Health. The digital radiography system is based on the Fuji 9000 computed radiography (CR) system which uses a storage phosphor imaging plate as the receptor. High resolution plates (HR-V) are used in this study. Dual-energy is one technique to reduce the structured noise associated with the complexity of the background of normal anatomy surrounding a lesion. This can be done by taking the advantage of the x-ray attenuation characteristics of two different structures such as soft tissue and bone in chest radiography. We have applied this technique to the detection of microcalcifications in mammography. The overall system performance based on this technique is evaluated. Results presented are based on the evaluation of phantom images.
Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L
2006-12-01
The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.
Mammography screening in six diverse communities in Chicago--a population study.
Whitman, Steve; Shah, Ami M; Silva, Abigail; Ansell, David
2007-01-01
Despite the fact that recent studies suggest a narrowing in access to mammography, Black women are much more likely to die from breast cancer than White women. Data at the community level regarding mammography screening can help explain health disparities and inform plans for improved screening efforts. In 2002-2003, a comprehensive household health survey in English or Spanish was conducted in six community areas with 1700 households. The module on mammography was based on a state-based nationwide health survey and included questions on frequency of mammography, repeat screenings, and several demographic variables. The proportion of women >or=40 years (n=482) who received a mammogram in the past 2 years ranged from 74% to 90% across the six communities. The community with the highest screening proportion was predominantly Mexican and included recent immigrants. The screening proportion in the poorest community area, which was all Black, was 77%. Women with health insurance, higher income, and more education were more likely to receive a mammogram. Proportions for women >or=50 years (n=286) were slightly higher but similar. Repeat screening, which is recommended, occurred at lower levels. Access to and utilization of mammography have grown in recent years so that even these vulnerable communities had screening proportions at or even higher than the national average and the Healthy People Year 2010 objective. Nonetheless, repeat screening sequences were lower and may require attention if mammography screening efforts are to have a greater impact on female breast cancer mortality.
Sardanelli, Francesco; Aase, Hildegunn S; Álvarez, Marina; Azavedo, Edward; Baarslag, Henk J; Balleyguier, Corinne; Baltzer, Pascal A; Beslagic, Vanesa; Bick, Ulrich; Bogdanovic-Stojanovic, Dragana; Briediene, Ruta; Brkljacic, Boris; Camps Herrero, Julia; Colin, Catherine; Cornford, Eleanor; Danes, Jan; de Geer, Gérard; Esen, Gul; Evans, Andrew; Fuchsjaeger, Michael H; Gilbert, Fiona J; Graf, Oswald; Hargaden, Gormlaith; Helbich, Thomas H; Heywang-Köbrunner, Sylvia H; Ivanov, Valentin; Jónsson, Ásbjörn; Kuhl, Christiane K; Lisencu, Eugenia C; Luczynska, Elzbieta; Mann, Ritse M; Marques, Jose C; Martincich, Laura; Mortier, Margarete; Müller-Schimpfle, Markus; Ormandi, Katalin; Panizza, Pietro; Pediconi, Federica; Pijnappel, Ruud M; Pinker, Katja; Rissanen, Tarja; Rotaru, Natalia; Saguatti, Gianni; Sella, Tamar; Slobodníková, Jana; Talk, Maret; Taourel, Patrice; Trimboli, Rubina M; Vejborg, Ilse; Vourtsis, Athina; Forrai, Gabor
2017-07-01
EUSOBI and 30 national breast radiology bodies support mammography for population-based screening, demonstrated to reduce breast cancer (BC) mortality and treatment impact. According to the International Agency for Research on Cancer, the reduction in mortality is 40 % for women aged 50-69 years taking up the invitation while the probability of false-positive needle biopsy is <1 % per round and overdiagnosis is only 1-10 % for a 20-year screening. Mortality reduction was also observed for the age groups 40-49 years and 70-74 years, although with "limited evidence". Thus, we firstly recommend biennial screening mammography for average-risk women aged 50-69 years; extension up to 73 or 75 years, biennially, is a second priority, from 40-45 to 49 years, annually, a third priority. Screening with thermography or other optical tools as alternatives to mammography is discouraged. Preference should be given to population screening programmes on a territorial basis, with double reading. Adoption of digital mammography (not film-screen or phosphor-plate computer radiography) is a priority, which also improves sensitivity in dense breasts. Radiologists qualified as screening readers should be involved in programmes. Digital breast tomosynthesis is also set to become "routine mammography" in the screening setting in the next future. Dedicated pathways for high-risk women offering breast MRI according to national or international guidelines and recommendations are encouraged. • EUSOBI and 30 national breast radiology bodies support screening mammography. • A first priority is double-reading biennial mammography for women aged 50-69 years. • Extension to 73-75 and from 40-45 to 49 years is also encouraged. • Digital mammography (not film-screen or computer radiography) should be used. • DBT is set to become "routine mammography" in the screening setting in the next future.
NASA Astrophysics Data System (ADS)
Heidari, Morteza; Zargari Khuzani, Abolfazl; Danala, Gopichandh; Mirniaharikandehei, Seyedehnafiseh; Qian, Wei; Zheng, Bin
2018-03-01
Both conventional and deep machine learning has been used to develop decision-support tools applied in medical imaging informatics. In order to take advantages of both conventional and deep learning approach, this study aims to investigate feasibility of applying a locally preserving projection (LPP) based feature regeneration algorithm to build a new machine learning classifier model to predict short-term breast cancer risk. First, a computer-aided image processing scheme was used to segment and quantify breast fibro-glandular tissue volume. Next, initially computed 44 image features related to the bilateral mammographic tissue density asymmetry were extracted. Then, an LLP-based feature combination method was applied to regenerate a new operational feature vector using a maximal variance approach. Last, a k-nearest neighborhood (KNN) algorithm based machine learning classifier using the LPP-generated new feature vectors was developed to predict breast cancer risk. A testing dataset involving negative mammograms acquired from 500 women was used. Among them, 250 were positive and 250 remained negative in the next subsequent mammography screening. Applying to this dataset, LLP-generated feature vector reduced the number of features from 44 to 4. Using a leave-onecase-out validation method, area under ROC curve produced by the KNN classifier significantly increased from 0.62 to 0.68 (p < 0.05) and odds ratio was 4.60 with a 95% confidence interval of [3.16, 6.70]. Study demonstrated that this new LPP-based feature regeneration approach enabled to produce an optimal feature vector and yield improved performance in assisting to predict risk of women having breast cancer detected in the next subsequent mammography screening.
Automatic patient dose registry and clinical audit on line for mammography.
Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M
2015-07-01
The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
[Hierarchy structuring for mammography technique by interpretive structural modeling method].
Kudo, Nozomi; Kurowarabi, Kunio; Terashita, Takayoshi; Nishimoto, Naoki; Ogasawara, Katsuhiko
2009-10-20
Participation in screening mammography is currently desired in Japan because of the increase in breast cancer morbidity. However, the pain and discomfort of mammography is recognized as a significant deterrent for women considering this examination. Thus quick procedures, sufficient experience, and advanced skills are required for radiologic technologists. The aim of this study was to make the point of imaging techniques explicit and to help understand the complicated procedure. We interviewed 3 technologists who were highly skilled in mammography, and 14 factors were retrieved by using brainstorming and the KJ method. We then applied Interpretive Structural Modeling (ISM) to the factors and developed a hierarchical concept structure. The result showed a six-layer hierarchy whose top node was explanation of the entire procedure on mammography. Male technologists were related to as a negative factor. Factors concerned with explanation were at the upper node. We gave attention to X-ray techniques and considerations. The findings will help beginners improve their skills.
Radiology workstation for mammography: preliminary observations, eyetracker studies, and design
NASA Astrophysics Data System (ADS)
Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.
1991-07-01
For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.
Digital Mammography with a Mosaic of CCD-Arrays
NASA Technical Reports Server (NTRS)
Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)
1996-01-01
The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.
Study of signal-to-noise ratio in digital mammography
NASA Astrophysics Data System (ADS)
Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie
2009-02-01
Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.
NASA Astrophysics Data System (ADS)
Greiter, Matthias B.; Hoeschen, Christoph
2010-04-01
The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.
Assessing the patient's mammogram experience.
Dodendorf, Diane M; Deogun, Gurvinder K; Rodie, Amy Risch; Pol, Louis G
2004-01-01
This study overviews an operational blueprint that diagrams the activities and interactions of all participants in a typical screening mammography appointment in a large medical center. The blueprint is constructed from multiple sources of data collected from mammography patients, service providers in the radiology department, and medical records. The benefits from using patient perspectives, the insights gained from the blueprint development process, and the value of the resulting screening mammography appointment blueprint are included.
Comparative Study Of Image Enhancement Algorithms For Digital And Film Mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delgado-Gonzalez, A.; Sanmiguel, R. E.
2008-08-11
Here we discuss the application of edge enhancement algorithms on images obtained with a Mammography System which has a Selenium Detector and on the other hand, on images obtained from digitized film mammography. Comparative analysis of such images includes the study of technical aspects of image acquisition, storage, compression and display. A protocol for a local database has been created as a result of this study.
Ahn, Hye Shin; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Bohyoung; Ko, Eun Sook; Han, Boo-Kyung; Chang, Jung Min; Yi, Ann; Cho, Nariya; Moon, Woo Kyung; Choi, Hye Young
2014-01-01
To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. During a 22-month period, we prospectively enrolled 100 cases of specimen FFDM mammography (Brestige®), which was performed alone or in combination with a post-processing algorithm developed by the manufacturer: group A (SMA), specimen mammography without application of "Mammogram enhancement ver. 2.0"; group B (SMB), specimen mammography with application of "Mammogram enhancement ver. 2.0". Two sets of specimen mammographies were randomly reviewed by five experienced radiologists. Image quality, lesion detection, diagnostic performance, and priority rank with regard to image preference were evaluated. Three aspects of image quality (overall quality, contrast, and noise) of the SMB were significantly superior to those of SMA (p < 0.05). SMB was significantly superior to SMA for visualizing calcifications (p < 0.05). Diagnostic performance, as evaluated by cancer score, was similar between SMA and SMB. SMB was preferred to SMA by four of the five reviewers. The post-processing algorithm may improve image quality with better image preference in FFDM than without use of the software.
Response costs of mammography adherence: Iranian women's perceptions.
Khodayarian, Mahsa; Mazloomi-Mahmoodabad, Seyed Saied; Lamyian, Minoor; Morowatisharifabad, Mohammad Ali; Tavangar, Hossein
2016-01-01
Mammography as the most common secondary prevention method has known to be helpful in detecting breast cancer at the early stages. Low level of participation among women toward mammography uptake due to cultural beliefs is a great concern. This study aimed at exploring the perceptions of women about response costs of mammography adherence (MA) in Yazd, Iran. A qualitative study using semi-structured interviews was performed. Fourteen women,one oncology nurse, and a breast cancer survivor were purposefully interviewed. Interviews were transcribed verbatim and analyzed by directed content analysis method based on protection motivation theory (PMT). One main theme was emerged from the analysis namely called "response costs".Two main categories were also emerged from the data; (1) psychological barriers with six subcategories including "embarrassment," "worry about being diagnosed with cancer," "preoccupation with underlying disease," "misconception about mammography," "need for an accompanying person," and "internalizing the experiences of the others," and (2) maladaptive coping modes which encompassed three subcategories: "religious faith," "fatalism," and"avoidance and denial." Useful information was provided about the response costs of mammography utilization based on the perceptions of women. Cognitive barriers may be decreased by conducting modifications in women's awareness and attitude toward MA as well as changing the national health system infrastructures. Incorporating religious and cultural belief systems into MA educational programs through motivational messages is recommended.
Mammography use and its demographic correlates among women in South Korea.
Suh, Eunyoung E; Park, Sunhee
2009-06-01
This study aimed to investigate the mammography rate and its demographic correlates among Korean women in order to provide basic understanding of factors related to the performance of mammography as a method of breast cancer screening. A descriptive secondary analysis was conducted using a national data set from the Korean National Health and Nutrition Examination Survey (KNHNES III) in South Korea. A total number of 2,602 women over 40 years of age were chosen for the analysis. Main research variables included the use of mammography, monthly income, residential area, age, marriage, education, insurance, smoking habits, drinking habits, job type, current health status, and other cancer screening results. Only 30.59% of women adhered to the national guidelines. Monthly income, age, education, insurance, and smoking habits had statistically significant effects on breast cancer screening performance. The demographic correlates of the performance of mammography highlight the fact that not all Korean women, at this stage, are in a socioeconomic or societal position to undergo biannual mammography screening. Targeted and tailored nursing intervention should be implemented in middle- and senior-aged women who lack the ability to access medical resources in South Korea. This will make it possible for marginalized women to utilize cancer screening tests and in turn promote their health.
NASA Astrophysics Data System (ADS)
Lee, Seungwan; Kang, Sooncheol; Eom, Jisoo
2017-03-01
Contrast-enhanced mammography has been used to demonstrate functional information about a breast tumor by injecting contrast agents. However, a conventional technique with a single exposure degrades the efficiency of tumor detection due to structure overlapping. Dual-energy techniques with energy-integrating detectors (EIDs) also cause an increase of radiation dose and an inaccuracy of material decomposition due to the limitations of EIDs. On the other hands, spectral mammography with photon-counting detectors (PCDs) is able to resolve the issues induced by the conventional technique and EIDs using their energy-discrimination capabilities. In this study, the contrast-enhanced spectral mammography based on a PCD was implemented by using a polychromatic dual-energy model, and the proposed technique was compared with the dual-energy technique with an EID in terms of quantitative accuracy and radiation dose. The results showed that the proposed technique improved the quantitative accuracy as well as reduced radiation dose comparing to the dual-energy technique with an EID. The quantitative accuracy of the contrast-enhanced spectral mammography based on a PCD was slightly improved as a function of radiation dose. Therefore, the contrast-enhanced spectral mammography based on a PCD is able to provide useful information for detecting breast tumors and improving diagnostic accuracy.
Sani, Karim Ghazikhanlou; Jafari, Mahmoodreza; Rostampoor, Nima
2011-01-01
The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were taken from other views (predominantly oblique views), making a total number of 128 radiographs. Paired radiographs, taken from the same areas, were compared by two radiologists in terms of image visual sharpness, presence of bony fractures, and soft tissue injuries. The surface dose received by patients in the two systems was also compared. The radiographs taken by mammography film-screen had a statistically better visual sharpness compared to those taken by the standard film-screen system. However, there was no statistically significant difference between the diagnostic accuracy of the two systems. Mammography film-screen was able to detect only one out of 57 lesions, whereas standard film-screen system did not detec any lesion. The surface dose received by patients in mammography film-screen was higher than that in standard film-screen system. The findings of the present study suggest that mammography film-screen may be recommended as a diagnostic tool for the detection of small fractures of tinny parts of body such as fingers, hand or foot. They also suggest that mammography film-screen has no advantage over standard film-screen for radiography of thick body parts such as neck and knee. PMID:23115417
Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S
2006-04-01
The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups <40, 40-49, 50-59 and >59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.
Eden, Karen B; Scariati, Paula; Klein, Krystal; Watson, Lindsey; Remiker, Mark; Hribar, Michelle; Forro, Vanessa; Michaels, LeAnn; Nelson, Heidi D
2015-12-01
Clinical guidelines recommend a personalized approach to mammography screening for women in their forties; however, methods to do so are lacking. An evidence-based mammography screening decision aid was developed as an electronic mobile application and evaluated in a before-after study. The decision aid (Mammopad) included modules on breast cancer, mammography, risk assessment, and priority setting about screening. Women aged 40-49 years who were patients of rural primary care clinics, had no major risk factors for breast cancer, and no mammography during the previous year were invited to use the decision aid. Twenty women participated in pretesting of the decision aid and 75 additional women completed the before-after study. The primary outcome was decisional conflict measured before and after using Mammopad. Secondary outcomes included decision self-efficacy and intention to begin or continue mammography screening. Differences comparing measures before versus after use were determined using Wilcoxon signed rank tests. After using Mammopad, women reported reduced decisional conflict based on mean Decisional Conflict Scale scores overall (46.33 versus 8.33; Z = -7.225; p < 0.001) and on all subscales (p < 0.001). Women also reported increased mean Decision Self-Efficacy Scale scores (79.67 versus 95.73; Z = 6.816, p < 0.001). Although 19% of women changed their screening intentions, this was not statistically significant. Women reported less conflict about their decisions for mammography screening, and felt more confident to make decisions after using Mammopad. This approach may help guide women through the decision making process to determine personalized screening choices that are appropriate for them.
Gennaro, G; Ballaminut, A; Contento, G
2017-09-01
This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.
... mammography facility know about breast implants when scheduling a mammogram. The technologist and radiologist must be experienced in performing mammography on women who have breast implants. If the technologist ...
Vedantham, Srinivasan; Shi, Linxi; Michaelsen, Kelly E.; Krishnaswamy, Venkataramanan; Pogue, Brian W.; Poplack, Steven P.; Karellas, Andrew; Paulsen, Keith D.
2016-01-01
A multimodality system combining a clinical prototype digital breast tomosynthesis with its imaging geometry modified to facilitate near-infrared spectroscopic imaging has been developed. The accuracy of parameters recovered from near-infrared spectroscopy is dependent on fibroglandular tissue content. Hence, in this study, volumetric estimates of fibroglandular tissue from tomosynthesis reconstructions were determined. A kernel-based fuzzy c-means algorithm was implemented to segment tomosynthesis reconstructed slices in order to estimate fibroglandular content and to provide anatomic priors for near-infrared spectroscopy. This algorithm was used to determine volumetric breast density (VBD), defined as the ratio of fibroglandular tissue volume to the total breast volume, expressed as percentage, from 62 tomosynthesis reconstructions of 34 study participants. For a subset of study participants who subsequently underwent mammography, VBD from mammography matched for subject, breast laterality and mammographic view was quantified using commercial software and statistically analyzed to determine if it differed from tomosynthesis. Summary statistics of the VBD from all study participants were compared with prior independent studies. The fibroglandular volume from tomosynthesis and mammography were not statistically different (p=0.211, paired t-test). After accounting for the compressed breast thickness, which were different between tomosynthesis and mammography, the VBD from tomosynthesis was correlated with (r =0.809, p<0.001), did not statistically differ from (p>0.99, paired t-test), and was linearly related to, the VBD from mammography. Summary statistics of the VBD from tomosynthesis were not statistically different from prior studies using high-resolution dedicated breast computed tomography. The observation of correlation and linear association in VBD between mammography and tomosynthesis suggests that breast density associated risk measures determined for mammography are translatable to tomosynthesis. Accounting for compressed breast thickness is important when it differs between the two modalities. The fibroglandular volume from tomosynthesis reconstructions is similar to mammography indicating suitability for use during near-infrared spectroscopy. PMID:26941961
Ranger, R; Butler, P; Yahnke, C; Valentino, D
2012-06-01
To develop and validate an Optically Stimulated Luminescent (OSL) dosimeter for exposure control verification of x-ray projection mammography imaging systems. The active detection element of the dosimeter is a strip of OSL material 3.0 mm wide, 0.13 mm thick and 30.0 mm long with an overlying aluminum step wedge with thicknesses of 0, 0.2, 0.4 and 0.6 mm Al, encapsulated in a light-tight plastic enclosure with outer dimensions of 10.0 mm wide, 5.4 mm thick, and 54.0 mm long. The dosimeter is used in conjunction with a breast phantom for the purpose of estimating the half-value layer (HVL), entrance surface exposure (ESE), and average glandular dose (AGD) in conventional projection mammography. ESE and HVL were computed based on analysis of exposure profiles obtained from exposed strip dosimeters. The AGD was estimated by multiplying the ESE by the appropriate exposure to dose conversion factor for the thickness and % glandular tissue fraction represented by the phantom and target-filter combination employed. The accuracy and reproducibility of the ESE, HVL and AGD estimates obtained using the dosimeter positioned on the surface of the ACR phantom at the chest wall edge, was evaluated using mammography systems utilizing different imaging receptor technology, i.e. screen-film (SF), computed radiography (CR) and direct radiography (DR) and compared against results obtained using a calibrated ion chamber fitted with a mammography probe. ESE, AGD and HVL results obtained using the OSL mammography QA dosimeter agreed with results obtained using an ion chamber to within 5-10%, depending on the target-filter combination used. Repeat readings were highly consistent with a coefficient of variation = 5%. The OSL mammography QA dosimeter has been shown to effectively estimate ESE, HVL and AGD, demonstrating its usefulness for secondary monitoring of output exposure of mammography imaging systems. © 2012 American Association of Physicists in Medicine.
Dedicated breast CT: geometric design considerations to maximize posterior breast coverage
NASA Astrophysics Data System (ADS)
Vedantham, Srinivasan; Karellas, Andrew; Emmons, Margaret M.; Moss, Lawrence J.; Hussain, Sarwat; Baker, Stephen P.
2013-06-01
An Institutional Review Board-approved protocol was used to quantify breast tissue inclusion in 52 women, under conditions simulating both craniocaudal (CC) and mediolateral oblique (MLO) views in mammography, dedicated breast CT in the upright subject position, and dedicated breast CT in the prone subject position. Using skin as a surrogate for the underlying breast tissue, the posterior aspect of the breast that is aligned with the chest-wall edge of the breast support in a screen-film mammography system was marked with the study participants positioned for CC and MLO views. The union of skin marks with the study participants positioned for CC and MLO views was considered to represent chest-wall tissue available for imaging with mammography and served as the reference standard. For breast CT, a prone stereotactic breast biopsy unit and a custom-fabricated barrier were used to simulate conditions during prone and upright breast CT, respectively. For the same breast marked on the mammography system, skin marks were made along the breast periphery that was just anterior to the apertures of the prone biopsy unit and the upright barrier. The differences in skin marks between subject positioning simulating breast CT (prone, upright) and mammography were quantified at six anatomic locations. For each location, at least one study participant had a skin mark from breast CT (prone, upright) posterior to mammography. However for all study participants, there was at least one anatomic location where the skin mark from mammography was posterior to that from breast CT (prone, upright) positioning. The maximum amount by which the skin mark from mammography was posterior to breast CT (prone and upright) over all six locations was quantified for each study participant and pair-wise comparison did not exhibit statistically significant difference between prone and upright breast CT (paired t- test, p = 0.4). Quantitatively, for 95% of the study participants the skin mark from mammography was posterior to breast CT (prone or upright) by at the most 9 mm over all six locations. Based on the study observations, geometric design considerations targeting chest-wall coverage with breast CT equivalent to mammography, wherein part of the x-ray beam images through the swale during breast CT are provided. Assuming subjects can extend their chest in to a swale, the optimal swale-depth required to achieve equivalent coverage with breast CT images as mammograms for 95% of the subjects varies in the range of ˜30-50 mm for clinical prototypes and was dependent on the system geometry.
Akpinar, Yeliz Yelen; Baykan, Zeynep; Naçar, Melis; Gün, Iskender; Çetinkaya, Fevziye
2011-01-01
The awareness of health professionals about breast cancer prevention is of vital importance, since their beliefs and behaviors may have a major impact on other women. The aim of this study was to investigate the knowledge, and attitudes regarding risk factors for breast cancer as well as screening such as breast self-examination, clinical breast examination and mammography among different groups of female health professionals. In this cross- sectional study, 444 female health professionals in various health centers located in Corum Province, Turkey, were interviewed using a self-administered questionnaire. The mean age was 33.1 ± 6.1 and most were married (81.3%). The rate of feeling under risk regarding breast cancer among female health personnel was 31.3%. The majority (98.4 %) perceived breast self-examination as a beneficial method for the early detection of breast cancer. Although 81.3 % of the participants stated that they did breast self examination, only 27.3 % reported doing so on a regular basis (performed monthly or once per menstrual cycle). The most common reason for not doing breast self-examination was the belief that it was not necessary (45.8 %). Of the entire group, the rate of having a mammography was 10.1% and the rate of clinical breast examination was 24.8%. Health professionals are a direct source of medical information to the public. The use of breast self-examination and mammography was found lower than expected when considering the fact that participants were health care professionals.
Medina-Shepherd, Rosario; Kleier, Jo Ann
2010-01-01
Victoria Champion used the constructs of the Health Belief Model as the foundation for developing Champion's Health Belief Scales for Mammography Screening (CHBMS). The instrument has been used to collect health beliefs about breast screening behaviors among various ethnic populations but has not been translated, adapted, or psychometrically evaluated in the Hispanic population. The purpose of this article was to report the translation and adaptation process from English to Spanish and the psychometric estimates of the validity and reliability of CHBMS-Spanish. The original instrument was translated from English to Spanish by a professional translator and back-translated into English by a focus group of healthcare professionals. The tool was given to 5 monolingual women to evaluate for content validity, translation validity, and cultural appropriateness. A total of 200 self-identified Hispanic women, literate in speaking and reading Spanish, aged 45 to 75 years, and without history of breast cancer were included in the analyses. The items of the scale formed coherent subsets that were relatively independent of each other and aligned to the 3 factors prescribed by the Health Belief Model constructs. Internal consistency values presented acceptable Cronbach alpha levels ranging from .69 to .83. Test-retest reliability correlations were .57 for susceptibility, .63 for benefits, and .83 for barriers. Overall, the Spanish version of CHBMS demonstrated acceptable preliminary values of reliability and validity. Further psychometric testing is recommended. The Spanish version of the CHBMS can be used by practicing nurses as an instrument to assess health beliefs concerning mammography screening among Spanish-speaking Hispanic women.
Is Mammography Useful in Older Women
1999-06-01
mammography in women age 70 and older . Using the Linked Medicare-SEER Tumor Registry Database, created by the National Cancer Institute and the Health Care... Health Interview Survey) have documented that mammography use decreases with advancing age (11,21,22). In 1993, only 25% of women age 65 and older ...related health services research. The linked database contains cancer information on patients 65 years of age and older from NCI’s SEER Program and
Update on new technologies in digital mammography
Patterson, Stephanie K; Roubidoux, Marilyn A
2014-01-01
Despite controversy regarding mammography’s efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. PMID:25152634
The Future of Contrast-Enhanced Mammography.
Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K
2018-02-01
The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.
Dual-energy contrast-enhanced spectral mammography (CESM).
Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian
2015-10-01
Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.
[What kind of information do German health information pamphlets provide on mammography screening?].
Kurzenhäuser, Stephanie
2003-02-01
To make an informed decision on participation in mammography screening, women have to be educated about all the risks and benefits of the procedure in a manner that is detailed and understandable. But an analysis of 27 German health pamphlets on mammography screening shows that many relevant pieces of information about the benefits, the risks, and especially the meaning of screening results are only insufficiently communicated. Many statements were presented narratively rather than as precise statistics. Depending on content, 17 to 62% of the quantifiable statements were actually given as numerical data. To provide comprehensive information and to avoid misunderstandings, it is necessary to supplement the currently available health pamphlets and make the information on mammography screening more precise.
Comparison of breast density measurements made using ultrasound tomography and mammography
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Krycia, Mark; Sherman, Mark E.; Boyd, Norman; Gierach, Gretchen L.
2015-03-01
Women with elevated mammographic percent density, defined as the ratio of fibroglandular tissue area to total breast area on a mammogram are at an increased risk of developing breast cancer. Ultrasound tomography (UST) is an imaging modality that can create tomographic sound speed images of a patient's breast, which can then be used to measure breast density. These sound speed images are useful because physical tissue density is directly proportional to sound speed. The work presented here updates previous results that compared mammographic breast density measurements with UST breast density measurements within an ongoing study. The current analysis has been expanded to include 158 women with negative digital mammographic screens who then underwent a breast UST scan. Breast density was measured for both imaging modalities and preliminary analysis demonstrated strong and positive correlations (Spearman correlation coefficient rs = 0.703). Additional mammographic and UST related imaging characteristics were also analyzed and used to compare the behavior of both imaging modalities. Results suggest that UST can be used among women with negative mammographic screens as a quantitative marker of breast density that may avert shortcomings of mammography.
NASA Astrophysics Data System (ADS)
Li, Yane; Fan, Ming; Cheng, Hu; Zhang, Peng; Zheng, Bin; Li, Lihua
2018-01-01
This study aims to develop and test a new imaging marker-based short-term breast cancer risk prediction model. An age-matched dataset of 566 screening mammography cases was used. All ‘prior’ images acquired in the two screening series were negative, while in the ‘current’ screening images, 283 cases were positive for cancer and 283 cases remained negative. For each case, two bilateral cranio-caudal view mammograms acquired from the ‘prior’ negative screenings were selected and processed by a computer-aided image processing scheme, which segmented the entire breast area into nine strip-based local regions, extracted the element regions using difference of Gaussian filters, and computed both global- and local-based bilateral asymmetrical image features. An initial feature pool included 190 features related to the spatial distribution and structural similarity of grayscale values, as well as of the magnitude and phase responses of multidirectional Gabor filters. Next, a short-term breast cancer risk prediction model based on a generalized linear model was built using an embedded stepwise regression analysis method to select features and a leave-one-case-out cross-validation method to predict the likelihood of each woman having image-detectable cancer in the next sequential mammography screening. The area under the receiver operating characteristic curve (AUC) values significantly increased from 0.5863 ± 0.0237 to 0.6870 ± 0.0220 when the model trained by the image features extracted from the global regions and by the features extracted from both the global and the matched local regions (p = 0.0001). The odds ratio values monotonically increased from 1.00-8.11 with a significantly increasing trend in slope (p = 0.0028) as the model-generated risk score increased. In addition, the AUC values were 0.6555 ± 0.0437, 0.6958 ± 0.0290, and 0.7054 ± 0.0529 for the three age groups of 37-49, 50-65, and 66-87 years old, respectively. AUC values of 0.6529 ± 0.1100, 0.6820 ± 0.0353, 0.6836 ± 0.0302 and 0.8043 ± 0.1067 were yielded for the four mammography density sub-groups (BIRADS from 1-4), respectively. This study demonstrated that bilateral asymmetry features extracted from local regions combined with the global region in bilateral negative mammograms could be used as a new imaging marker to assist in the prediction of short-term breast cancer risk.
Vomweg, T W; Buscema, M; Kauczor, H U; Teifke, A; Intraligi, M; Terzi, S; Heussel, C P; Achenbach, T; Rieker, O; Mayer, D; Thelen, M
2003-09-01
The aim of this study was to evaluate the capability of improved artificial neural networks (ANN) and additional novel training methods in distinguishing between benign and malignant breast lesions in contrast-enhanced magnetic resonance-mammography (MRM). A total of 604 histologically proven cases of contrast-enhanced lesions of the female breast at MRI were analyzed. Morphological, dynamic and clinical parameters were collected and stored in a database. The data set was divided into several groups using random or experimental methods [Training & Testing (T&T) algorithm] to train and test different ANNs. An additional novel computer program for input variable selection was applied. Sensitivity and specificity were calculated and compared with a statistical method and an expert radiologist. After optimization of the distribution of cases among the training and testing sets by the T & T algorithm and the reduction of input variables by the Input Selection procedure a highly sophisticated ANN achieved a sensitivity of 93.6% and a specificity of 91.9% in predicting malignancy of lesions within an independent prediction sample set. The best statistical method reached a sensitivity of 90.5% and a specificity of 68.9%. An expert radiologist performed better than the statistical method but worse than the ANN (sensitivity 92.1%, specificity 85.6%). Features extracted out of dynamic contrast-enhanced MRM and additional clinical data can be successfully analyzed by advanced ANNs. The quality of the resulting network strongly depends on the training methods, which are improved by the use of novel training tools. The best results of an improved ANN outperform expert radiologists.
Social and cultural meanings of self-efficacy.
Burke, Nancy J; Bird, Joyce A; Clark, Melissa A; Rakowski, William; Guerra, Claudia; Barker, Judith C; Pasick, Rena J
2009-10-01
This article describes the influences of social context on women's health behavior through illustration of the powerful influences of social capital (the benefits and challenges that accrue from participation in social networks and groups) on experiences and perceptions of self-efficacy. The authors conducted inductive interviews with Latino and Filipino academics and social service providers and with U.S.-born and immigrant Latinas and Filipinas to explore direct and indirect influences of social context on health behaviors such as mammography screening. Iterative thematic analysis identified themes (meanings of efficacy, spheres of efficacy, constraints on efficacy, sources of social capital, and differential access to and quality of social capital) that link the domain of social capital with the behavioral construct perceived self-efficacy. The authors conclude that social capital addresses aspects of social context absent in the current self-efficacy construct and that these aspects have important implications for scholars' and practitioners' understandings of health behavior and intervention development.
Celaya, Maria O; Berke, Ethan M; Onega, Tracy L; Gui, Jiang; Riddle, Bruce L; Cherala, Sai S; Rees, Judy R
2010-01-01
Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Using the state's population-based cancer registry, all female residents of New Hampshire aged > or =40 years who were diagnosed with breast cancer during 1998-2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998-2004. Their mean driving distance to the nearest mammography facility was 8.85 km (range 0-44.26; 5.5 miles, range 0-27.5), with a mean estimated travel time of 8.9 min (range 0.0-42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months (p=0.074). Most women living in New Hampshire have good geographical access to mammography, and no indication was found that travel time or travel distance to mammography significantly affected stage at breast cancer diagnosis. Health insurance, age and marital status were the major factors associated with later stage breast cancer. The study contributes to an ongoing debate over geographic access to screening mammography in different states, which have given contradictory results. These inconsistencies in the rural health literature highlight a need to understand the complexity of defining rural and urban residence; to characterize more precisely the issues that contribute to good preventive care in different rural communities; and to appreciate the efforts already made in some rural states to provide good geographic access to preventive care. In New Hampshire, specific subgroups such as the uninsured and the elderly remain at greatest risk of being diagnosed with later stage breast cancer and may benefit from targeted interventions to improve early detection.
Dunn, Sheila F; Lofters, Aisha K; Ginsburg, Ophira M; Meaney, Christopher A; Ahmad, Farah; Moravac, M Catherine; Nguyen, Cam Tu Janet; Arisz, Angela M
2017-05-01
Marginalized populations such as immigrants and refugees are less likely to receive cancer screening. Cancer Awareness: Ready for Education and Screening (CARES), a multifaceted community-based program in Toronto, Canada, aimed to improve breast and cervical screening among marginalized women. This matched cohort study assessed the impact of CARES on cervical and mammography screening among under-screened/never screened (UNS) attendees. Provincial administrative data collected from 1998 to 2014 and provided in 2015 were used to match CARES participants who were age eligible for screening to three controls matched for age, geography, and pre-education screening status. Dates of post-education Pap and mammography screening up to June 30, 2014 were determined. Analysis in 2016 compared screening uptake and time to screening for UNS participants and controls. From May 15, 2012 to October 31, 2013, a total of 1,993 women attended 145 educational sessions provided in 20 languages. Thirty-five percent (118/331) and 48% (99/206) of CARES participants who were age eligible for Pap and mammography, respectively, were UNS on the education date. Subsequently, 26% and 36% had Pap and mammography, respectively, versus 9% and 14% of UNS controls. ORs for screening within 8 months of follow-up among UNS CARES participants versus their matched controls were 5.1 (95% CI=2.4, 10.9) for Pap and 4.2 (95%=CI 2.3, 7.8) for mammography. Hazard ratios for Pap and mammography were 3.6 (95% CI=2.1, 6.1) and 3.2 (95% CI=2.0, 5.3), respectively. CARES' multifaceted intervention was successful in increasing Pap and mammography screening in this multiethnic under-screened population. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Samah, Asnarulkhadi Abu; Ahmadian, Maryam
2012-01-01
The rates of breast cancer have increased over the past two decades, and this raises concern about physical, psychological and social well-being of women with breast cancer. Further, few women really want to do breast cancer screening. We here investigated the socio-demographic correlates of mammography participation among 400 asymptomatic Iranian women aged between 35 and 69. A cross-sectional survey was conducted at the four outpatient clinics of general hospitals in Tehran during the period from July through October, 2009. Bi-variate analyses and multi-variate binary logistic regression were employed to find the socio- demographic predictors of mammography utilization among participants. The rate of mammography participation was 21.5% and relatively high because of access to general hospital services. More women who had undergone mammography were graduates from university or college, had full-time or part-time employment, were insured whether public or private, reported a positive family history of breast cancer, and were in the middle income level (P <0.01).The largest number of participating women was in the age range of 41 to 50 years. The results of multivariate logistic regression further showed that education (95%CI: 0.131-0.622), monthly income (95%CI: 0.038-0.945), and family history of breast cancer (95%CI: 1.97-9.28) were significantly associated (all P <0.05)with mammography participation. The most important issue for a successful screening program is participation. Using a random sample, this study found that the potential predictor variables of mammography participation included a higher education level, a middle income level, and a positive family history of breast cancer for Iranian women after adjusting for all other demographic variables in the model.
Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S
2017-01-01
Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016.
Rafferty, Elizabeth A; Rose, Stephen L; Miller, Dave P; Durand, Melissa A; Conant, Emily F; Copit, Debra S; Friedewald, Sarah M; Plecha, Donna M; Ott, Ingrid L; Hayes, Mary K; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Niklason, Loren T
2017-08-01
To determine the effect of tomosynthesis imaging as a function of age for breast cancer screening. Screening performance metrics from 13 institutions were examined for 12 months prior to introduction of tomosynthesis (period 1) and compared to those after introduction of tomosynthesis (period 2, range 3-22 months). Screening metrics for women ages 40-49, 50-59, 60-69, and 70+ , included rates per 1000 screens for recalls, biopsies, cancers, and invasive cancers detected. Performance parameters were compared for women screened with digital mammography alone (n = 278,908) and digital mammography + tomosynthesis (n = 173,414). Addition of tomosynthesis to digital mammography produced significant reductions in recall rates for all age groups and significant increases in cancer detection rates for women 40-69. Largest recall rate reduction with tomosynthesis was for women 40-49, decreasing from 137 (95% CI 117-156) to 115 (95% CI 95-135); difference, -22 (95% CI -26 to -18; P < .001). Simultaneous increase in invasive cancer detection rate for women 40-49 from 1.6 (95% CI 1.2-1.9) to 2.7 (95% CI 2.2-3.1) with tomosynthesis (difference, 1.1; 95% CI 0.6-1.6; P < .001) was observed. Addition of tomosynthesis to digital mammography increased invasive cancer detection rates for women 40-69 and decreased recall rates for all age groups with largest performance gains seen in women 40-49. The similar performance seen with tomosynthesis screening for women in their 40s compared to digital mammography for women in their 50s argues strongly for commencement of mammography screening at age 40 using tomosynthesis.
Nikitovic-Jokic, Milica; Holubowich, Corinne
2016-01-01
Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Among women at high risk for breast cancer, magnetic resonance imaging (MRI) has been suggested as a safe adjunct (supplemental) screening tool that can detect breast cancers missed on screening mammography, potentially reducing the number of deaths associated with the disease. However, the use of adjunct screening tests may also increase the number of false-positive test results, which may lead to unnecessary follow-up testing, as well as patient stress and anxiety. We investigated the benefits and harms of MRI as an adjunct to mammography compared with mammography alone for screening women at less than high risk (average or higher than average risk) for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects (DARE), Centre for Reviews and Dissemination (CRD) Health Technology Assessment Database, and National Health Service (NHS) Economic Evaluation Database, from January 2002 to January 2016, for evidence of effectiveness, harms, and diagnostic accuracy. Only studies evaluating the use of screening breast MRI as an adjunct to mammography in the specified populations were included. Results No studies in women at less than high risk for breast cancer met our inclusion criteria. Conclusions It remains uncertain if the use of adjunct screening breast MRI in women at less than high risk (average or higher than average risk) for breast cancer will reduce breast cancer–related mortality without significant increases in unnecessary follow-up testing and treatment. PMID:27990198
NASA Astrophysics Data System (ADS)
Samala, Ravi K.; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A.; Richter, Caleb; Cha, Kenny
2018-02-01
We propose a cross-domain, multi-task transfer learning framework to transfer knowledge learned from non-medical images by a deep convolutional neural network (DCNN) to medical image recognition task while improving the generalization by multi-task learning of auxiliary tasks. A first stage cross-domain transfer learning was initiated from ImageNet trained DCNN to mammography trained DCNN. 19,632 regions-of-interest (ROI) from 2,454 mass lesions were collected from two imaging modalities: digitized-screen film mammography (SFM) and full-field digital mammography (DM), and split into training and test sets. In the multi-task transfer learning, the DCNN learned the mass classification task simultaneously from the training set of SFM and DM. The best transfer network for mammography was selected from three transfer networks with different number of convolutional layers frozen. The performance of single-task and multitask transfer learning on an independent SFM test set in terms of the area under the receiver operating characteristic curve (AUC) was 0.78+/-0.02 and 0.82+/-0.02, respectively. In the second stage cross-domain transfer learning, a set of 12,680 ROIs from 317 mass lesions on DBT were split into validation and independent test sets. We first studied the data requirements for the first stage mammography trained DCNN by varying the mammography training data from 1% to 100% and evaluated its learning on the DBT validation set in inference mode. We found that the entire available mammography set provided the best generalization. The DBT validation set was then used to train only the last four fully connected layers, resulting in an AUC of 0.90+/-0.04 on the independent DBT test set.
Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha
2017-09-01
To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.
Russell, Kathleen M; Champion, Victoria L; Monahan, Patrick O; Millon-Underwood, Sandra; Zhao, Qianqian; Spacey, Nicole; Rush, Nathan L; Paskett, Electra D
2010-01-01
Low-income African American women face numerous barriers to mammography screening. We tested the efficacy of a combined interactive computer program and lay health advisor intervention to increase mammography screening. In this randomized, single blind study, participants were 181 African American female health center patients of ages 41 to 75 years, at < or =250% of poverty level, with no breast cancer history, and with no screening mammogram in the past 15 months. They were assigned to either (a) a low-dose comparison group consisting of a culturally appropriate mammography screening pamphlet or (b) interactive, tailored computer instruction at baseline and four monthly lay health advisor counseling sessions. Self-reported screening data were collected at baseline and 6 months and verified by medical record. For intent-to-treat analysis of primary outcome (medical record-verified mammography screening, available on all but two participants), the intervention group had increased screening to 51% (45 of 89) compared with 18% (16 of 90) for the comparison group at 6 months. When adjusted for employment status, disability, first-degree relatives with breast cancer, health insurance, and previous breast biopsies, the intervention group was three times more likely (adjusted relative risk, 2.7; 95% confidence interval, 1.8-3.7; P < 0.0001) to get screened than the low-dose comparison group. Similar results were found for self-reported mammography stage of screening adoption. The combined intervention was efficacious in improving mammography screening in low-income African American women, with an unadjusted effect size (relative risk, 2.84) significantly higher (P < 0.05) than that in previous studies of each intervention alone.
Gummersbach, Elisabeth; in der Schmitten, Jürgen; Abholz, Heinz-Harald; Wegscheider, Karl; Pentzek, Michael
2013-10-01
In order to give informed consent for mammography screening, women need to be told the relevant facts; however, screening information often remains vague because of the worry that detailed information might deter women from participating in recommended screening programs. Since September 2010, German women aged 50 to 69 invited for mammography screening have received a new, comprehensive information brochure that frankly discusses the potential benefit and harm of mammography screening. In contrast, the brochure that was in use before September 2010 contained little relevant information.The aim of this study is to compare the impact of the two different brochures on the intention of women to undergo mammography screening, and to broaden our understanding of the effect that factual information has on the women's decision-making. This is a controlled questionnaire study comparing knowledge, views and hypothetical preferences of women aged 48-49 years after receiving the old versus the new information brochure. German GP's in the region of North Rhine-Westfalia will be asked by mail and telephone to participate in the study. Eligible women will be recruited via their general practitioners (GPs) and randomized to groups A ('new brochure') and B ('old brochure'), with an intended recruitment of 173 participants per group. The study is powered to detect a 15% higher or lower intention to undergo mammography screening in women informed by the new brochure. This study will contribute to our understanding of the decision-making of women invited to mammography screening. From both ethical and public health perspectives, it is important to know whether frank, factual information leads to a change in the intention of women to participate in a recommended breast cancer screening program. DRKS00004271.
2013-01-01
Background In order to give informed consent for mammography screening, women need to be told the relevant facts; however, screening information often remains vague because of the worry that detailed information might deter women from participating in recommended screening programs. Since September 2010, German women aged 50 to 69 invited for mammography screening have received a new, comprehensive information brochure that frankly discusses the potential benefit and harm of mammography screening. In contrast, the brochure that was in use before September 2010 contained little relevant information. The aim of this study is to compare the impact of the two different brochures on the intention of women to undergo mammography screening, and to broaden our understanding of the effect that factual information has on the women’s decision-making. Methods This is a controlled questionnaire study comparing knowledge, views and hypothetical preferences of women aged 48–49 years after receiving the old versus the new information brochure. German GP’s in the region of North Rhine-Westfalia will be asked by mail and telephone to participate in the study. Eligible women will be recruited via their general practitioners (GPs) and randomized to groups A ('new brochure’) and B ('old brochure’), with an intended recruitment of 173 participants per group. The study is powered to detect a 15% higher or lower intention to undergo mammography screening in women informed by the new brochure. Discussion This study will contribute to our understanding of the decision-making of women invited to mammography screening. From both ethical and public health perspectives, it is important to know whether frank, factual information leads to a change in the intention of women to participate in a recommended breast cancer screening program. Trial registration DRKS00004271 PMID:24083811
Characterization of scatter in digital mammography from physical measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leon, Stephanie M., E-mail: Stephanie.Leon@uth.tmc.edu; Wagner, Louis K.; Brateman, Libby F.
2014-06-15
Purpose: That scattered radiation negatively impacts the quality of medical radiographic imaging is well known. In mammography, even slight amounts of scatter reduce the high contrast required for subtle soft-tissue imaging. In current clinical mammography, image contrast is partially improved by use of an antiscatter grid. This form of scatter rejection comes with a sizeable dose penalty related to the concomitant elimination of valuable primary radiation. Digital mammography allows the use of image processing as a method of scatter correction that might avoid effects that negatively impact primary radiation, while potentially providing more contrast improvement than is currently possible withmore » a grid. For this approach to be feasible, a detailed characterization of the scatter is needed. Previous research has modeled scatter as a constant background that serves as a DC bias across the imaging surface. The goal of this study was to provide a more substantive data set for characterizing the spatially-variant features of scatter radiation at the image detector of modern mammography units. Methods: This data set was acquired from a model of the radiation beam as a matrix of very narrow rays or pencil beams. As each pencil beam penetrates tissue, the pencil widens in a predictable manner due to the production of scatter. The resultant spreading of the pencil beam at the detector surface can be characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were calculated from measurements obtained using the beam stop method. Two digital mammography units were utilized, and the SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and presence or absence of a grid. These values were then used to generate general equations allowing the SF and MRE to be calculated for any combination of the above parameters. Results: With a grid, the SF ranged from a minimum of about 0.05 to a maximum of about 0.16, and the MRE ranged from about 3 to 13 mm. Without a grid, the SF ranged from a minimum of 0.25 to a maximum of 0.52, and the MRE ranged from about 20 to 45 mm. The SF with a grid demonstrated a mild dependence on target/filter combination and kV, whereas the SF without a grid was independent of these factors. The MRE demonstrated a complex relationship as a function of kV, with notable difference among target/filter combinations. The primary source of change in both the SF and MRE was phantom thickness. Conclusions: Because breast tissue varies spatially in physical density and elemental content, the effective thickness of breast tissue varies spatially across the imaging field, resulting in a spatially-variant scatter distribution in the imaging field. The data generated in this study can be used to characterize the scatter contribution on a point-by-point basis, for a variety of different techniques.« less
Web-based mammography audit feedback.
Geller, Berta M; Ichikawa, Laura; Miglioretti, Diana L; Eastman, David
2012-06-01
Interpreting screening mammography accurately is challenging and requires ongoing education to maintain and improve interpretative skills. Recognizing this, many countries with organized breast screening programs have developed audit and feedback systems using national performance data to help radiologists assess and improve their skills. We developed and tested an interactive Website to provide screening and diagnostic mammography audit feedback with comparisons to national and regional benchmarks. Radiologists who participate in three Breast Cancer Surveillance Consortium registries in the United States were invited during 2009 and 2010 to use a Website that provides tabular and graphical displays of mammography audit reports with comparisons to national and regional performance measures. We collected data about the use and perceptions of the Website. Thirty-five of 111 invited radiologists used the Website from one to five times in a year. The most popular measure was sensitivity for both screening and diagnostic mammography, whereas a table with all measures was the most visited page. Of the 13 radiologists who completed the postuse survey, all found the Website easy to use and navigate, 11 found the benchmarks useful, and nine reported that they intended to improve a specific outcome measure that year. An interactive Website to provide customized mammography audit feedback reports to radiologists has the potential to be a powerful tool in improving interpretive performance. The conceptual framework of customized audit feedback reports can also be generalized to other imaging tests.
Improving mammography screening among the medically underserved.
Davis, Terry C; Rademaker, Alfred; Bennett, Charles L; Wolf, Michael S; Carias, Edson; Reynolds, Cristalyn; Liu, Dachao; Arnold, Connie L
2014-04-01
We evaluated the effectiveness and cost-effectiveness of alternative interventions designed to promote mammography in safety-net settings. A three-arm, quasi-experimental evaluation was conducted among eight federally qualified health clinics in predominately rural Louisiana. Mammography screening efforts included: 1) enhanced care, 2) health literacy-informed education of patients, and 3) education plus nurse support. Outcomes included mammography screening completion within 6 months and incremental cost-effectiveness. Overall, 1,181 female patients ages 40 and over who were eligible for routine mammography were recruited. Baseline screening rates were < 10%. Post intervention screening rates were 55.7% with enhanced care, 51.8% with health literacy-informed education and 65.8% with education and nurse support. After adjusting for race, marital status, self-efficacy and literacy, patients receiving health-literacy informed education were not more likely to complete mammographic screening than those receiving enhanced care; those additionally receiving nurse support were 1.37-fold more likely to complete mammographic screening than those receiving the brief education (95% Confidence Interval 1.08-1.74, p = 0.01). The incremental cost per additional women screened was $2,457 for literacy-informed education with nurse support over literacy-informed education alone. Mammography rates were increased substantially over existing baseline rates in all three arms with the educational initiative, with nurse support and follow-up being the most effective option. However, it is not likely to be cost-effective or affordable in resource-limited clinics.
Corrêa, Rosangela da Silveira; Freitas-Junior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia Fonseca; Dias, Cíntia Melazo; Ferreira, Rubemar de Souza; Rahal, Rosemar Macedo Souza
2012-10-01
To assess the effectiveness of a quality control program in mammography services of the Brazilian National Health System (SUS). A prospective study using temporal analysis of a health surveillance action was conducted. A total of 35 service providers that had mammography equipment in operation and regularly performed exams between 2007 and 2009 in the state of Goiás, Central-Western Brazil, participated in this study. Services were assessed during three site visits by performance testing of mammography equipment, film processors, and other materials, and image quality and entrance surface dose in a phantom were also assessed. Each service was scored according to the percentage of tests that conformed to standards. The mean percentage for compliance among the participating service providers were 64.1% (± 13.3%) in the first visit, 68.4% (± 15.9%) in the second, and 77.1% (± 13.3%) in the third (p < 0.001). The main improvements resulted from adjustments to the breast compression force, the automatic exposure control system, and the alignment of the compression paddle. The doses measured were within the conformity range in 80% of the services assessed. The implementation of this program in the mammography services was effective at improving the operational parameters of the mammography machines, although 40% of the services did not reach the acceptable level of 70%. This result indicates the need to continue this health surveillance action.
Frequency and determinants of screening for breast cancer in primary care group practice.
Love, R R; Brown, R L; Davis, J E; Baumann, L J; Fontana, S A; Sanner, L A
1993-09-27
Many studies reporting the frequency of breast cancer screening have been based only on physician and patient surveys or on data from quality assurance studies and do not assess the reliability of information obtained from these various sources. To obtain more complete data we studied mammography performed in a 3-year period, 1988 through 1991, in 24 nonacademic primary care group practices by both auditing the medical records and obtaining questionnaire responses from 1819 women aged 53 to 62 years and from their 98 physicians in the nonmetropolitan Midwest. Medical record data indicated that mammography was performed in all 3 years in 16.7%, in at least two of 3 years in 49.8%, and in at least one of 3 years in 81.7% of women. While patient reports of a family history of breast cancer, health insurance coverage for mammography, and greater annual household income were each significant predictors, a patient report that a clinic staff member had discussed mammography was the strongest predictor of greater frequency of mammography. In this study of self-selected physicians and their patients, record-documented mammographic examinations were considerably more frequent than has been reported in some studies, but occurred at rates consistent with quality assurance data for the region. These data suggest that clinic staff initiatives with screening mammography have a large impact.
Cost-Effectiveness of Three Rounds of Mammography Breast Cancer Screening in Iranian Women
Haghighat, Shahpar; Akbari, Mohammad Esmaeil; Yavari, Parvin; Javanbakht, Mehdi; Ghaffari, Shahram
2016-01-01
Background Breast cancer is the most common cancer in Iranian women as is worldwide. Mammography screening has been introduced as a beneficial method for reducing mortality and morbidity of this disease. Objectives We developed an analytical model to assess the cost effectiveness of an organized mammography screening program in Iran for early detection of the breast cancer. Patients and Methods This study is an economic evaluation of mammography screening program among Iranian woman aged 40 - 70 years. A decision tree and Markov model were applied to estimate total quality adjusted life years (QALY) and lifetime costs. Results The results revealed that the incremental cost effectiveness ratio (ICER) of mammography screening in Iranian women in the first round was Int. $ 37,350 per QALY gained. The model showed that the ICER in the second and third rounds of screening program were Int. $ 141,641 and Int. $ 389,148 respectively. Conclusions Study results identified that mammography screening program was cost-effective in 53% of the cases, but incremental cost per QALY in the second and third rounds of screening are much higher than the accepted payment threshold of Iranian health system. Thus, evaluation of other screening strategies would be useful to identify more cost-effective program. Future studies with new national data can improve the accuracy of our finding and provide better information for health policy makers for decision making. PMID:27366315
A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.
Costa, A M; Caldas, L V E
2003-01-01
A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.
Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M.; Grau, Ana M.; Champion, Victoria L.; Wallston, Kenneth A.
2010-01-01
This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR = 2.53, 95% CI = 1.12–5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value = .02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted. PMID:20173286
Fair, Alecia Malin; Wujcik, Debra; Lin, Jin-Mann Sally; Zheng, Wei; Egan, Kathleen M; Grau, Ana M; Champion, Victoria L; Wallston, Kenneth A
2010-02-01
This article targets the relationship between psychosocial determinants and abnormal screening mammography follow-up in a medically underserved population. Health belief scales were modified to refer to diagnostic follow-up versus annual screening. A retrospective cohort study design was used. Statistical analyses were performed examining relationships among sociodemographic factors, psychosocial determinants, and abnormal mammography follow-up. Women with lower mean internal health locus of control scores (3.14) were two times more likely than women with higher mean internal health locus of control scores (3.98) to have inadequate follow-up (OR=2.53, 95% CI=1.12-5.36). Women with less than a high school education had lower cancer fatalism scores than women who had completed high school (47.5 vs. 55.2, p-value=.02) and lower mean external health locus of control scores (3.0 vs. 5.3) (p-value<.01). These constructs have implications for understanding mammography follow-up among minority and medically underserved women. Further comprehensive study of these concepts is warranted.
Mammography Adherence in African-American Women: Results of a Randomized Controlled Trial.
Gathirua-Mwangi, Wambui G; Monahan, Patrick O; Stump, Timothy; Rawl, Susan M; Skinner, Celette Sugg; Champion, Victoria L
2016-02-01
Breast cancer is the second leading cause of cancer mortality among women in the developed world. Mammography screening is especially important for African-Americans because they experience a greater mortality (OR = 1.38) than Caucasians despite having a lower incidence of breast cancer. The purpose of this study was to compare the effects of two interventions with usual care on mammography adherence among African-American women. A subsample of African-American women (n = 244) aged 41-65 years who had not had a mammogram in the last 15 months and no history of breast cancer was randomly assigned to receive (1) mailed interactive DVD, (2) computer-tailored telephone counseling, or (3) usual care. The DVD intervention was five times more effective than usual care for promoting mammography screening at 6 months follow-up among women who earned less than $30,000 (OR = 5.3). Compared to usual care, neither the DVD nor phone produced significant effects for women with household incomes >$30,000. Use of a mailed DVD for low-income African-American women may be an effective way to increase mammography adherence.
NASA Astrophysics Data System (ADS)
Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco
2008-08-01
The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.
Predictors of mammography screening among ethnically diverse low-income women.
Cronan, Terry A; Villalta, Ian; Gottfried, Emily; Vaden, Yavette; Ribas, Mabel; Conway, Terry L
2008-05-01
Breast cancer is the second leading cause of cancer deaths among women in the United States. Minority women are less likely to be screened and more likely to die from breast cancer than are Caucasian women. Although some studies have examined ethnic disparities in mammography screening, no study has examined whether there are ethnic disparities among low-income, ethnically diverse women. The present study was designed to determine whether there are ethnic disparities in mammography screening and predictors of screening among low-income African American, Mexican American, and Caucasian women, and to determine whether the disparities and predictors vary across ethnic groups. The participants were 146 low-income women who were Mexican American (32%), African American (31%), or Caucasian (37%). Statistical analyses were performed to assess the relationships between mammography screening during the past 2 years and potential predictors of screening, both within ethnic groups and for the combined sample. The results varied depending on whether analyses combined ethnic groups or were performed within each of the three ethnic groups. It is, therefore, important to examine within-group differences when examining ethnic disparities in predictors of mammography.
Screening mammography uptake within Australia and Scotland in rural and urban populations
Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M.; Henderson, Robert; Watson, Angus; Kyle, Richard G.; Hubbard, Gill; Mullen, Russell; Atherton, Iain
2015-01-01
Objective To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Method Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946–51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Results Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06–1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01–1.31). Conclusions The absence of rural–urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography. PMID:26844118
Screening mammography uptake within Australia and Scotland in rural and urban populations.
Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M; Henderson, Robert; Watson, Angus; Kyle, Richard G; Hubbard, Gill; Mullen, Russell; Atherton, Iain
2015-01-01
To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946-51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06-1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01-1.31). The absence of rural-urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez
2008-08-11
The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less
... fatty tissue. On a mammogram, fatty tissue appears dark (radio-lucent) and the glandular and connective tissues ... white on mammography) and non-dense fatty tissue (dark on mammography) using a visual scale and assign ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kharrati, Hedi
2005-05-01
In this study, a new approach has been introduced for derivation of the effective dose from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to the effective dose for the mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium, National Institute of Standards and Technology, and International Atomic Energy Agency laboratories. The results show that, in all cases, the effective dose in mammography energy range is less than 25% of the incident air kerma for the primary and the scatter radiations andmore » does not exceed 75% for the leakage radiation.« less
April-Sanders, Ayana; Oskar, Sabine; Shelton, Rachel C.; Schmitt, Karen; Desperito, Elise; Protacio, Angeline; Tehranifar, Parisa
2017-01-01
Objective Worry about developing breast cancer (BC worry) has been associated with participation in screening and genetic testing and with follow-up of abnormal screening results. Little is known about the scope and predictors of BC worry in Hispanic and immigrant populations. Methods We collected in-person interview data from 250 self-identified Hispanic women recruited from an urban mammography facility (average age 50.4 years; 82% foreign-born). Women reported whether they worried about developing breast cancer rarely/never (low worry), sometimes (moderate worry) or often/all the time (high worry). We examined whether sociocultural and psychological factors (e.g., acculturation, education, perceived risk), and risk factors and objective risk for breast cancer (e.g., family history, Gail model 5-year risk estimates, parity) predicted BC worry using multinomial and binary logistic regression. Results In multivariable models, women who perceived higher absolute breast cancer risk (OR=1.66, 95% CI: 1.28, 2.14 for one unit increase in perceived lifetime risk) and comparative breast cancer risk (e.g., OR=2.37, 95% CI: 1.23, 6.06) were more likely to report high BC worry than moderate or low BC worry. There were no associations between BC worry and indicators of objective risk or acculturation. Conclusions In Hispanic women undergoing screening mammography, higher perceptions of breast cancer risk, on both absolute and comparative terms, were independently associated with high BC worry, and were stronger predictors of BC worry than indicators of objective breast cancer risk, including family history, mammographic density and personal breast cancer risk estimates. PMID:27863982
Changing behavior and accuracy with time on task in mammography screening
NASA Astrophysics Data System (ADS)
Taylor-Phillips, Sian; Jenkinson, David; Stinton, Chris; Wallis, Matthew G.; Clarke, Aileen
2017-03-01
Background: The vigilance decrement and prevalence effect both describe changes to speed and accuracy with time on task. Whilst there is much laboratory based research on these effects, little is known about whether they occur in real world mammography practice. Methods: The Changing Case Order to Optimise Patterns of Performance in Screening (CO-OPS) trial randomised 37,724 batches containing 1.2 million women attending breast screening to intervention or control (222,208 from the Midlands of England). In the control arm the batch was examined in the same order by both readers, in the intervention arm it was examined in a different order by both readers. Time taken, recall decision by both readers, and cancers detected were recorded for each case, and used to examine patterns of performance with time on task. Results: 49,575 women were recalled and 10,484 had cancer detected. Median time taken to examine each case was 35 seconds (out of cases where time taken was 10 minutes or less). The intervention did not affect overall cancer detection rates or recall rates. A more detailed analysis of the Midlands data indicates cancer detection rate did not change when reading up to 60 cases in a batch, but recall rate reduced. Time taken per case reduced with time on task, from a median 41 seconds when examining the second case in the batch to 28.5 seconds examining the 60th case. Conclusion: Reader behavior and performance systematically changes with time on task in breast screening.
NASA Astrophysics Data System (ADS)
Zhao, Amy; Santana, Maira; Samei, Ehsan; Lo, Joseph
2017-03-01
In traditional radiography and computed tomography (CT), contrast is an important measure of image quality that, in theory, does not vary with dose. While increasing dose may increase the overall contrast-to-noise ratio (CNR), the contrast in an image should be primarily dependent on variation in tissue density and attenuation. We investigated the behavior of all three currently FDA-approved vendors' 3D DBT systems (Siemens, Hologic, and General Electric (GE)) using the Computerized Imaging Reference Systems (CIRS) Model 011A Breast Phantom and found that for both Siemens and Hologic systems, contrast increased with dose across multiple repeated trials. For these two systems, experimental CNR also appeared to increase above the expected CNR, which suggests that these systems seem to have introduced post-processing by manipulation of contrast, and thus DBT data cannot be used to reliably quantify tissue characteristics. Additional experimentation with both 2D mammography and 3D DBT systems from GE in addition to the previously mentioned vendors, however, suggested that this relationship is not true for all systems. An initial comparison of contrast vs. dose showed no relationship between contrast and dose for 2D mammography, with the contrast remaining relatively constant in the dose range of 33% of the automatic exposure control setting (AEC) to 300% AEC for all three vendors. The GE DBT system also did not exhibit increased contrast with increased dose, suggesting that the behavior of 3D DBT systems is vendor-specific.
Elimination of Cost Sharing for Screening Mammography in Medicare Advantage Plans.
Trivedi, Amal N; Leyva, Bryan; Lee, Yoojin; Panagiotou, Orestis A; Dahabreh, Issa J
2018-01-18
The Affordable Care Act (ACA) required most insurers and the Medicare program to eliminate cost sharing for screening mammography. We conducted a difference-in-differences study of biennial screening mammography among 15,085 women 65 to 74 years of age in 24 Medicare Advantage plans that eliminated cost sharing to provide full coverage for screening mammography, as compared with 52,035 women in 48 matched control plans that had and maintained full coverage. In plans that eliminated cost sharing, adjusted rates of biennial screening mammography increased from 59.9% (95% confidence interval [CI], 54.9 to 65.0) in the 2-year period before cost-sharing elimination to 65.4% (95% CI, 61.8 to 69.0) in the 2-year period thereafter. In control plans, the rates of biennial mammography were 73.1% (95% CI, 69.2 to 77.0) and 72.8% (95% CI, 69.7 to 76.0) during the same periods, yielding a difference in differences of 5.7 percentage points (95% CI, 3.0 to 8.4). The difference in differences was 9.8 percentage points (95% CI, 4.5 to 15.2) among women living in the areas with the highest quartile of educational attainment versus 4.3 percentage points (95% CI, 0.2 to 8.4) among women in the lowest quartile. As indicated by the difference-in-differences estimates, after the elimination of cost sharing, the rate of biennial mammography increased by 6.5 percentage points (95% CI, 3.7 to 9.4) for white women and 8.4 percentage points (95% CI, 2.5 to 14.4) for black women but was almost unchanged for Hispanic women (0.4 percentage points; 95% CI, -7.3 to 8.1). The elimination of cost sharing for screening mammography under the ACA was associated with an increase in rates of use of this service among older women for whom screening is recommended. The effect was attenuated among women living in areas with lower educational attainment and was negligible among Hispanic women. (Funded by the National Institute on Aging.).
Drake, Bettina F; Abadin, Salmafatima S; Lyons, Sarah; Chang, Su-Hsin; Steward, Lauren T; Kraenzle, Susan; Goodman, Melody S
2015-03-20
Among women, breast cancer is the most common non-cutaneous cancer and second most common cause of cancer-related death. The purpose of this study was to determine the extent to which women use mobile mammography vans for breast cancer screening and what factors are associated with repeat visits to these vans. A case-control study. Cases are women who had a repeat visit to the mammography van. (n=2134). Women who received a mammogram as part of Siteman Cancer Center's Breast Health Outreach Program responded to surveys and provided access to their clinical records (N=8450). Only visits from 2006 to 2014 to the mammography van were included. The main outcome is having a repeat visit to the mammography van. Among the participants, 25.3% (N=2134) had multiple visits to the mobile mammography van. Data were analysed using χ(2) tests, logistic regression and negative binomial regression. Women who were aged 50-65, uninsured, or African-American had higher odds of a repeat visit to the mobile mammography van compared with women who were aged 40-50, insured, or Caucasian (OR=1.135, 95% CI 1.013 to 1.271; OR=1.302, 95% CI 1.146 to 1.479; OR=1.281, 95% CI 1.125 to 1.457), respectively. However, the odds of having a repeat visit to the van were lower among women who reported a rural ZIP code or were unemployed compared with women who provided a suburban ZIP code or were employed (OR=0.503, 95% CI 0.411 to 0.616; OR=.868, 95% CI 0.774 to 0.972), respectively. This study has identified key characteristics of women who are either more or less likely to use mobile mammography vans as their primary source of medical care for breast cancer screening and have repeat visits. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bakhtavar, Khadijeh; Saran, Maryam; Behzadifar, Masoud; Farsi, Maryam
2017-08-01
Breast cancer is one of the health system problems and important diseases that is rising in developing and advanced countries. This study aimed to determine the difference of Magnetic Resonance Mammography (MRM) findings versus mammography in detecting multifocal, multi-centric and malignant bilateral lesions in patients with known breast cancer in Tehran. This cross-sectional study was conducted in Iran and Tehran among breast cancer patients between January 2015 and February 2016. Patients were included in the study prior to surgery, at the request of a surgeon with the aim of detecting multifocal, multi-centric and bilateral lesions. Demographic information was also collected from patients. The results for quantitative variables were expressed as mean and standard deviations, and for qualitative variables, were expressed as relative and absolute frequency. Chi-square test was used to compare the two methods. SPSS Ver.24 (IBM) software was used to analyze the data. Thirty-nine patients were enrolled in the study. The mean age of patients in this study was 48.46±6.836. In mammography, 13 (33.3%) had Composition C and 26 (66.7%) had Composition D according to the type of Composition. In total, 25 patients (89.3%) had one lesion and 3 patients (10.7%) had more than two lesions. In MRM, all lesions observed were mass (54 masses). The number of lesions found in MRM was 27 patients with one lesion (58.9%), 6 patients with two lesions (20.5%) and 5 patients with three lesions (20.6%). MRM detected more lesions compared to mammography (p<0.0001). The value of Chi-square test with a degree of freedom and error level of 0.05 was 3.71 and p<0.0001 that showed a significant relationship between the number of MRM findings in comparison with mammography. The results of our study showed that two or more lesions and bilateral lesions in MRM were more than mammography in women with B Breast Composition C, D; the findings showed that MRM has a better ability to detect breast masses, and can affect the patient's surgical procedure.
Miglioretti, Diana L.; Lange, Jane; van den Broek, Jeroen J.; Lee, Christoph I.; van Ravesteyn, Nicolien T.; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J.; Melnikow, Joy; de Koning, Harry J.; Hubbard, Rebecca A.
2016-01-01
Background Estimates of radiation-induced breast cancer risk from mammography screening have not previously considered dose exposure variation or diagnostic work-up after abnormal screening. Objective To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening, considering exposure from screening and diagnostic mammography and dose variation across women. Design Two simulation-modeling approaches using common data on screening mammography from the Breast Cancer Surveillance Consortium and radiation dose from mammography from the Digital Mammographic Imaging Screening Trial. Setting U.S. population. Patients Women aged 40–74 years. Interventions Annual or biennial digital mammography screening from age 40, 45, or 50 until 74. Measurements Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality per 100,000 women screened (harms). Results On average, annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancers (95% confidence interval [CI]=88–178) leading to 16 deaths (95% CI=11–23) relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 radiation-induced breast cancers leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete breast examination (8% of population) were projected to have higher radiation-induced breast cancer incidence and mortality (266 cancers, 35 deaths per 100,000 women), compared to women with small or average breasts (113 cancers, 15 deaths per 100,000 women). Biennial screening starting at age 50 reduced risk of radiation-induced cancers 5-fold. Limitations We were unable to estimate years of life lost from radiation-induced breast cancer. Conclusions Radiation-induced breast cancer incidence and mortality from digital mammography screening are impacted by dose variability from screening and resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may be at higher risk of radiation-induced breast cancer; however, the benefits of screening outweigh these risks. PMID:26756460
Secginli, Selda; Nahcivan, Nursen O
2011-01-01
Few studies have investigated breast health programs to promote rates of having a mammography, clinical breast examination and breast self-examination among non-adherent Turkish women. To determine the effectiveness of a breast health promotion program on mammography and clinical breast examination use, breast self-examination frequency and proficiency (breast self-examination skills and lump detection), breast health knowledge and health beliefs about breast cancer screening in a sample of Turkish women. Experimental (pretest-posttest control group). A community-based setting in Istanbul, Turkey. 190 Non-adherent women (intervention group=97, control group=93) aged 41 and older, residing in Istanbul, Turkey. The intervention group (n=97) received a 120-min breast health promotion program based on health belief model including a breast health education, film, breast self-examination instruction, and a booklet, a calendar, a card designed specifically for the study. The control group (n=93) received general information except breast health. Data were collected before the program, immediately after the program, and at 3- and 6-month post-program. The outcome measures are the mammography, clinical breast examination, and breast self-examination frequency, breast self-examination proficiency, breast health knowledge, and health beliefs (perceived susceptibility to breast cancer, benefits to mammography and breast self-examination, barriers of mammography and breast self-examination, confidence in performing breast self-examination). The breast health promotion program significantly increased breast self-examination frequency and proficiency and breast health knowledge. No significant differences existed in mammography and clinical breast examination rates between the two groups at 6 months. The program was effective in increasing perceived susceptibility to breast cancer, perceived benefits of mammography and breast self-examination, and confidence of breast self-examination. No significant difference was found between the two groups for perceived barriers to mammography. The breast health promotion program was effective in increasing breast self-examination frequency and proficiency in a sample of Turkish women. In addition, it appears to be useful in raising the knowledge of breast health, enhancing confidence in performing breast self-examination, and increasing most health belief levels. Copyright © 2010 Elsevier Ltd. All rights reserved.
Sprague, Brian L; Arao, Robert F; Miglioretti, Diana L; Henderson, Louise M; Buist, Diana S M; Onega, Tracy; Rauscher, Garth H; Lee, Janie M; Tosteson, Anna N A; Kerlikowske, Karla; Lehman, Constance D
2017-04-01
Purpose To establish contemporary performance benchmarks for diagnostic digital mammography with use of recent data from the Breast Cancer Surveillance Consortium (BCSC). Materials and Methods Institutional review board approval was obtained for active or passive consenting processes or to obtain a waiver of consent to enroll participants, link data, and perform analyses. Data were obtained from six BCSC registries (418 radiologists, 92 radiology facilities). Mammogram indication and assessments were prospectively collected for women undergoing diagnostic digital mammography and linked with cancer diagnoses from state cancer registries. The study included 401 548 examinations conducted from 2007 to 2013 in 265 360 women. Results Overall diagnostic performance measures were as follows: cancer detection rate, 34.7 per 1000 (95% confidence interval [CI]: 34.1, 35.2); abnormal interpretation rate, 12.6% (95% CI: 12.5%, 12.7%); positive predictive value (PPV) of a biopsy recommendation (PPV 2 ), 27.5% (95% CI: 27.1%, 27.9%); PPV of biopsies performed (PPV 3 ), 30.4% (95% CI: 29.9%, 30.9%); false-negative rate, 4.8 per 1000 (95% CI: 4.6, 5.0); sensitivity, 87.8% (95% CI: 87.3%, 88.4%); and specificity, 90.5% (95% CI: 90.4%, 90.6%). Among cancers detected, 63.4% were stage 0 or 1 cancers, 45.6% were minimal cancers, the mean size of invasive cancers was 21.2 mm, and 69.6% of invasive cancers were node negative. Performance metrics varied widely across diagnostic indications, with cancer detection rate (64.5 per 1000) and abnormal interpretation rate (18.7%) highest for diagnostic mammograms obtained to evaluate a breast problem with a lump. Compared with performance during the screen-film mammography era, diagnostic digital performance showed increased abnormal interpretation and cancer detection rates and decreasing PPVs, with less than 70% of radiologists within acceptable ranges for PPV 2 and PPV 3 . Conclusion These performance measures can serve as national benchmarks that may help transform the marked variation in radiologists' diagnostic performance into targeted quality improvement efforts. © RSNA, 2017 Online supplemental material is available for this article.
Mammography: MedlinePlus Health Topic
... National Center for Health Statistics) MQSA National Statistics (Food and Drug Administration) Women with Disabilities and Breast Cancer Screening (Centers for Disease Control and Prevention) Clinical Trials ClinicalTrials.gov: Mammography (National Institutes of ...
Celaya, MO; Berke, EM; Onega, TL; Gui, J; Riddle, BL; Cherala, SS; Rees, JR
2017-01-01
Introduction Early detection of breast cancer by screening mammography aims to increase treatment options and decrease mortality. Recent studies have shown inconsistent results in their investigations of the possible association between travel distance to mammography and stage of breast cancer at diagnosis. Objective The purpose of the study was to investigate whether geographic access to mammography screening is associated with the stage at breast cancer diagnosis. Methods Using the state’s population-based cancer registry, all female residents of New Hampshire aged ≥40 years who were diagnosed with breast cancer during 1998–2004 were identified. The factors associated with early stage (stages 0 to 2) or later stage (stages 3 and 4) diagnosis of breast cancer were compared, with emphasis on the distance a woman lived from the closest mammography screening facility, and residence in rural and urban locations. Results A total of 5966 New Hampshire women were diagnosed with breast cancer during 1998–2004. Their mean driving distance to the nearest mammography facility was 8.85km (range 0–44.26; 5.5 miles, range 0–27.5), with a mean estimated travel time of 8.9 min (range 0.0–42.2). The distribution of travel distance (and travel time) was substantially skewed to the right: 56% of patients lived within 8 km (5 miles) of a mammography facility, and 65% had a travel time of less than 10 min. There was no significant association between later stage of breast cancer and travel time to the nearest mammography facility. Using 3 categories of rural/urban residence based on Rural Urban Commuting Area classification, no significant association between rural residence and stage of diagnosis was found. New Hampshire women were more likely to be diagnosed with breast cancer at later stages if they lacked private health insurance (p<0.001), were not married (p<0.001), were older (p<0.001), and there was a borderline association with diagnosis during non-winter months (p=0.074). Conclusions Most women living in New Hampshire have good geographical access to mammography, and no indication was found that travel time or travel distance to mammography significantly affected stage at breast cancer diagnosis. Health insurance, age and marital status were the major factors associated with later stage breast cancer. The study contributes to an ongoing debate over geographic access to screening mammography in different states, which have given contradictory results. These inconsistencies in the rural health literature highlight a need to understand the complexity of defining rural and urban residence; to characterize more precisely the issues that contribute to good preventive care in different rural communities; and to appreciate the efforts already made in some rural states to provide good geographic access to preventive care. In New Hampshire, specific subgroups such as the uninsured and the elderly remain at greatest risk of being diagnosed with later stage breast cancer and may benefit from targeted interventions to improve early detection. PMID:20438282
Diffuse Optical Monitoring of the Neoadjuvant Breast Cancer Therapy
Choe, Regine; Durduran, Turgut
2012-01-01
Recent advances in the use of diffuse optical techniques for monitoring the hemodynamic, metabolic and physiological signatures of the neoadjuvant breast cancer therapy effectiveness is critically reviewed. An extensive discussion of the state-of-theart diffuse optical mammography is presented alongside a discussion of the current approaches to breast cancer therapies. Overall, the diffuse optics field is growing rapidly with a great deal of promise to fill an important niche in the current approaches to monitor, predict and personalize neoadjuvant breast cancer therapies. PMID:23243386
Does telephone scheduling assistance increase mammography screening adherence?
Payton, Colleen A; Sarfaty, Mona; Beckett, Shirley; Campos, Carmen; Hilbert, Kathleen
2015-11-01
The 2 objectives were: 1) describe the use of a patient navigation process utilized to promote adherence to mammography screening within a primary care practice, and 2) determine the result of the navigation process and estimate the time required to increase mammography screening with this approach in a commercially insured patient population enrolled in a health maintenance organization. An evaluation of a nonrandomized practice improvement intervention. Women eligible for mammography (n = 298) who did not respond to 2 reminder letters were contacted via telephone by a navigator who offered scheduling assistance for mammography screening. The patient navigator scheduled appointments, documented the number of calls, and confirmed completed mammograms in the electronic health record, as well as estimated the time for calls and chart review. Of the 188 participants reached by phone, 112 (59%) scheduled appointments using the patient navigator, 35 (19%) scheduled their own appointments independently prior to the call, and 41 (22%) declined. As a result of the telephone intervention, 78 of the 188 women reached (41%) received a mammogram; also, all 35 women who had independently scheduled a mammogram received one. Chart documentation confirmed that 113 (38%) of the cohort of 298 women completed a mammogram. The estimated time burden for the entire project was 55 hours and 33 minutes, including calling patients, scheduling appointments, and chart review. A patient navigator can increase mammography adherence in a previously nonadherent population by making the screening appointment while the patient is on the phone.
Scaperrotta, Gianfranco; Capalbo, Emanuela; Ferranti, Claudio; Falco, Giuseppe; Nava, Maurizio B; Di Leo, Gianni; Marchesini, Monica; Suman, Laura; Panizza, Pietro
2016-01-01
Breast reduction and mastopexy combined with inferior dermo-lipo-glandular flap (autoprosthesis) gives good breast shape, long-term projection, and upper pole fullness. We assess the impact on breast oncologic surveillance compared to other techniques. A total of 105 patients who underwent mastectomy and reconstruction were divided into 3 groups of 35 patients each: groups 1 and 2 include patients with contralateral breast symmetrization performed with and without autoprosthesis technique, respectively. Group 3 is a control group without contralateral breast reshaping. On mammography, edema, skin thickening, architectural distortion, and calcifications were recorded, as well as further diagnostic examinations, biopsies, and surgical treatments required. Statistically significant differences (p<0.001) in the first follow-up mammography between groups 1 and 2 were stromal edema (6% vs 51%) and architectural distortion (74% vs 63%). The latest findings meant architectural distortion also have significant difference (p<0.001) in the last mammography (79% vs 66%). Microcalcification has statistically significant difference (p<0.001) in the latest postsurgical mammography, increased in group 1. Skin thickening had a similar course in either group. Mammography follow-up was not impaired in most cases notwithstanding the parenchyma distortion as compared with mammography after breast-conserving surgery. Four core biopsies were performed in both groups: 3 new breast cancers and 1 benign epithelial hyperplasia were found. No difficulties were found impairing mammographic evaluation in patients treated with autoprosthesis as compared to other techniques.
Yen, Suh-May; Kung, Pei-Tseng; Tsai, Wen-Chen
2015-02-01
Women with mental illness are at increased risk of developing and dying from breast cancer and are thus in urgent need of breast cancer preventive care. This study examined the use of screening mammography by Taiwanese women with mental disabilities and analyzed factors affecting this use. 17,243 Taiwanese women with mental disabilities aged 50-69 years were retrospectively included as study subjects. Linked patient data were obtained from three national databases in Taiwan (the 2008 database of physically and mentally disabled persons, the Health Promotion Administration's 2007-2008 mammography screening data, and claims data from the National Health Insurance Research Database). Besides descriptive statistics and bivariate analysis, logistic regression analysis was also performed to examine factors affecting screening mammography use. The 2007-2008 mammography screening rate for Taiwanese women with mental disabilities was 8.79% (n=1515). Variables that significantly influenced screening use were income, education, presence of catastrophic illness/injury, severity of mental disability, and usage of other preventive care services. Screening was positively correlated with income and education. Those with catastrophic illness/injury were more likely to be screened (odds ratio [OR], 1.40; 95% CI=1.15-1.72). Severity of disability was negatively correlated with screening, with very severe, severe, and moderate disability being associated with 0.34-0.69 times the odds of screening as mild disability. In Taiwan, women with mental disabilities receive far less mammography screening than women in general. Copyright © 2014 Elsevier Ltd. All rights reserved.
Comparative effectiveness of mailed reminder letters on mammography screening compliance.
Romaire, Melissa A; Bowles, Erin J Aiello; Anderson, Melissa L; Buist, Diana S M
2012-08-01
Reminder letters are effective at prompting women to schedule mammograms. Less well studied are reminders addressing multiple preventive service recommendations. We compared the effectiveness of a mammogram-specific reminder sent when a woman was due for a mammogram to a reminder letter addressing multiple preventive services and sent on a woman's birthday on mammography receipt. The study included 48,583 women 52-74 years enrolled in Group Health Cooperative, a health plan in Washington State. From 2005 to 2009, women were mailed 88,605 mammogram-specific or birthday letters. In this one group pretest-posttest study, we modeled the odds of obtaining a screening mammogram after receiving a letter by reminder type using logistic regression, controlling for demographic and healthcare use characteristics and stratifying by whether women were overdue or up-to-date with mammography at the mailing. Among women up-to-date with screening, birthday letters were negatively associated with mammography receipt compared to mammogram-specific letters (birthday letters with 1-2 recommendations: OR=0.73; 95% CI:0.68-0.79; 3 recommendations: OR=0.74; 95% CI:0.69-0.78; 4-8 recommendations: OR=0.62 95% CI:0.55-0.68) after. Among overdue women, birthday letters with 4-8 recommendations were negatively associated with mammography receipt. Transitioning from mammogram-specific reminder letters to multiple preventive service birthday letters was associated with decreased mammography receipt. Copyright © 2012 Elsevier Inc. All rights reserved.
Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Rys, Janusz; Reinfuss, Marian
2014-01-01
Objective The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. Materials and Methods The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. Results MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). Conclusion CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography. PMID:25469079
Luczyńska, Elzbieta; Heinze-Paluchowska, Sylwia; Dyczek, Sonia; Blecharz, Pawel; Rys, Janusz; Reinfuss, Marian
2014-01-01
The goal of the study was to compare conventional mammography (MG) and contrast-enhanced spectral mammography (CESM) in preoperative women. The study was approved by the local Ethics Committee and all participants provided informed consent. The study included 152 consecutive patients with 173 breast lesions diagnosed on MG or CESM. All MG examinations and consults were conducted in one oncology centre. Non-ionic contrast agent, at a total dose of 1.5 mL/kg body weight, was injected intravenous. Subsequently, CESM exams were performed with a mammography device, allowing dual-energy acquisitions. The entire procedure was done within the oncology centre. Images from low and high energy exposures were processed together and the combination provided an "iodine" image which outlined contrast up-take in the breast. MG detected 157 lesions in 150 patients, including 92 infiltrating cancers, 12 non-infiltrating cancers, and 53 benign lesions. CESM detected 149 lesions in 128 patients, including 101 infiltrating cancers, 13 non-infiltrating cancers, and 35 benign lesions. CESM sensitivity was 100% (vs. 91% for MG), specificity was 41% (vs. 15% for MG), area under the receiver operating characteristic curve was 0.86 (vs. 0.67 for MG), and accuracy was 80% (vs. 65% for MG) for the diagnosis of breast cancer. Both MG and CESM overestimated lesion sizes compared to histopathology (p < 0.001). CESM may provide higher sensitivity for breast cancer detection and greater diagnostic accuracy than conventional mammography.
Use of a photoessay to teach low-income African American women about mammography.
Paskett, E D; Tatum, C; Wilson, A; Dignan, M; Velez, R
1996-01-01
Although incidence rates of breast cancer are lower among African American women than white women, mortality rates among African American women are higher, especially for women of lower socioeconomic levels. Reasons for this situation include the lesser use of breast cancer screening examinations by low-income, primarily African American women, late stage of diagnosis, and delays in treatment. As part of community outreach and public health clinic inreach programs for the Forsyth County Cancer Screening Project, approximately 908 African American women who reside in low-income housing communities were targeted for educational efforts related to breast cancer screening. Early in the project, it was discovered that many of the women were unfamiliar with mammography and had very little awareness of how the entire examination was conducted. This low level of knowledge was particularly important because it was a barrier for obtaining regular mammography. A photoessay depicting the process of getting a mammogram was developed and used in community outreach efforts in three formats: in educational classes, as a display in the housing communities, and in physicians' offices. The acceptability of this photoessay to communicate knowledge of and reduce fears about mammography was assessed through evaluation surveys in interviews with a sample of 47 women from the target population. Overall, these women liked the photoessay and felt that it provided knowledge about mammography and reduced fears associated with anticipating mammography. Strategies such as this may be ideal to communicate important information about cancer prevention and control in low-literacy populations.
Digital Mammography in Young Women: Is a Single View Sufficient?
Gossner, Johannes
2016-03-01
Single view mammography may be a less time consuming, more comfortable and radiation reduced alternative for young women, but there are no studies examining this approach after the implementation of digital mammography into clinical practice. Retrospective analysis of all mammographies performed in women younger than 40 years during a 24 month period. The sample consisted of 109 women with 212 examined breasts. All patients initially received standard two- view mammography. In the study setting the MLO- views were read by a single viewer and compared to a composite reference standard. In this sample 7 malignant findings were present and the review of the MLO-view detected 6 of them (85%). In patients with dense breasts 4 out of 5 malignant findings were found on the single-view (sensitivity 80%) and all 2 malignant findings were detected in patients with low breast density (sensitivity 100%). There were 7 false positive findings (3.3%). i.e. in total 8 out of 212 examined breasts were therefore misinterpreted (3.8%). Single view digital mammography detects the vast majority of malignant findings, especially in low density breast tissue and the rate of false-positive findings is within acceptable limits. Therefore this approach may be used in different scenarios (for example in increasing patient throughout in resource poor settings, reducing radiation burden in the young or in combination with ultrasound to use the strengths of both methods). More research on this topic is needed to establish its potential role in breast imaging.
Wang, Claire Tienwey; Greenwood, Nechama; White, Laura F; Wilkinson, Joanne
2015-05-01
Women with intellectual disabilities have similar breast cancer rates as the general population, but lower rates of regular mammography and higher breast cancer mortality rates. Although prior qualitative work demonstrates that women with intellectual disabilities face unique, disability-specific barriers to mammography, the present authors lack standardized, validated instruments for measuring knowledge of breast cancer screening in this population. In addition, much research related to adults with intellectual disabilities focuses on family or carer perspectives, rather than involving women with intellectual disabilities, themselves. The present authors first pilot tested a general population instrument measuring breast cancer knowledge, and found that it did not perform adequately in women with intellectual disabilities. In response, the present authors developed the Mammography Preparedness Measure (MPM), a direct short interview tool to measure knowledge and preparedness in women with intellectual disabilities, themselves, rather than relying on caregiver or other reports, and using inclusive methodology. The present authors validated the MPM by assessing test-retest reliability. Average test-retest per cent agreement of 84%, ranging from 74 to 91% agreement per item, with an overall kappa of 0.59. The MPM appears to be a valid instrument appropriate for measuring mammography preparedness in women with intellectual disabilities. The success of this innovative tool suggests that direct, rather than informant-directed tools can be developed to measure health knowledge and cancer screening readiness in adults with intellectual disabilities, an important measure in studying and reducing disparities. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ikejimba, Lynda; Kiarashi, Nooshin; Lin, Yuan; Chen, Baiyu; Ghate, Sujata V.; Zerhouni, Moustafa; Samei, Ehsan; Lo, Joseph Y.
2012-03-01
Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique that provides 3D structural information of the breast. In contrast to 2D mammography, DBT minimizes tissue overlap potentially improving cancer detection and reducing number of unnecessary recalls. The addition of a contrast agent to DBT and mammography for lesion enhancement has the benefit of providing functional information of a lesion, as lesion contrast uptake and washout patterns may help differentiate between benign and malignant tumors. This study used a task-based method to determine the optimal imaging approach by analyzing six imaging paradigms in terms of their ability to resolve iodine at a given dose: contrast enhanced mammography and tomosynthesis, temporal subtraction mammography and tomosynthesis, and dual energy subtraction mammography and tomosynthesis. Imaging performance was characterized using a detectability index d', derived from the system task transfer function (TTF), an imaging task, iodine contrast, and the noise power spectrum (NPS). The task modeled a 5 mm lesion containing iodine concentrations between 2.1 mg/cc and 8.6 mg/cc. TTF was obtained using an edge phantom, and the NPS was measured over several exposure levels, energies, and target-filter combinations. Using a structured CIRS phantom, d' was generated as a function of dose and iodine concentration. In general, higher dose gave higher d', but for the lowest iodine concentration and lowest dose, dual energy subtraction tomosynthesis and temporal subtraction tomosynthesis demonstrated the highest performance.
Copeland, Valire Carr; Kim, Yoo Jung; Eack, Shaun M
2017-11-21
The purpose of this study was to report the results of a meta-analysis conducted on the effects of clinical trials in breast cancer screening for African American women between 1997 and 2017. Articles published in English and in the United States, between January 1997 and March 2017, were eligible for inclusion if they (1) conducted psychosocial, behavioral, or educational interventions designed to increase screening mammography rates in predominantly African American women of all ages; (2) utilized a randomized, controlled trial (RCT) design; and (3) reported quantitative screening rates following the intervention. Randomized clinical trials on breast cancer screening in African American women, published between January 1997 and March 2017, were selected from database searches. Data collected included effect size of screening versus comparison interventions, intervention characteristics, and a number of study characteristics to explore potential moderators. Search results yielded 327 articles, of which 14 met inclusion criteria and were included in analyses. Findings indicated that screening interventions for African American women were significantly more likely to result in mammography than control (OR = 1.56 [95 percent CI = 1.27-1.93], p < .0001). Although no patient or study characteristics significantly moderated screening efficacy, the most effective interventions were those specifically tailored to meet the perceived risk of African American women. Screening interventions are at least minimally effective for promoting mammography among African American women, but research in this area is limited to a small number of studies. More research is needed to enhance the efficacy of existing interventions and reduce the high morbidity and mortality rate of this underserved population. © Health Research and Educational Trust.
Women's participation in breast cancer screening in France--an ethical approach.
Moutel, Grégoire; Duchange, Nathalie; Darquy, Sylviane; de Montgolfier, Sandrine; Papin-Lefebvre, Frédérique; Jullian, Odile; Viguier, Jérôme; Sancho-Garnier, Hélène
2014-08-16
Breast cancer is a major public health challenge. Organized mammography screening (OS) is considered one way to reduce breast cancer mortality. EU recommendations prone mass deployment of OS, and back in 2004, France introduced a national OS programme for women aged 50-74 years. However, in 2012, participation rate was still just 52.7%, well short of the targeted 70% objective. In an effort to re-address the (in) efficiency of the programme, the French National Cancer Institute has drafted an expert-group review of the ethical issues surrounding breast cancer mammography screening. Prompted by emerging debate over the efficiency of the screening scheme and its allied public information provision, we keynote the experts' report based on analysis of epidemiological data and participation rate from the public health authorities. The low coverage of the OS scheme may be partly explained by the fact that a significant number of women undergo mammography outside OS and thus outside OS criteria. These findings call for further thinking on (i) the ethical principles of beneficence and non-malfeasance underpinning this public health initiative, (ii) the reasons behind women's and professionals' behavior, and (iii) the need to analyze how information provision to women and the doctor-patient relationship need to evolve in response to scientific controversy over the risks and benefits of conducting mammographic screening. This work calls for a reappraisal of the provision of screening programme information. We advocate a move to integrate the points sparking debate over the efficiency of the screening scheme to guarantee full transparency. The perspective is to strengthen the respect for autonomy allowing women to make an informed choice in their decision on whether or not to participate.
Yu-Mei, Lee; Hsueh-Hua, Yao
2013-09-01
The incidence of breast cancer has had a four-fold increase from 1980 to 2005 in Taiwan. Limited data have been available on mobile breast screening in the Taiwanese population since 2009. This study aims at investigating the factors influencing consensus opinion on the recall for mobile breast screening in Taiwan. The factors were categorized by individual health background, socioeconomic status and knowledge about breast screening. There were 502 questionnaires collected from Taiwanese women examined on mobile mammography screening vehicle. Data were then analyzed by SPSS 12 via analysis of variance (ANOVA), F-test, t-test or chi-square test. Strong participation was associated with a younger age, higher educational level, higher incomes, previous history of cancer, previous family history of cancer, one or two prior mammographies, more correct recognitions of mammography, recall rate, and breast cancer risk. If the false-positive result occurred, 83.9%, 81.9% and 77.3% of the women agreed or strongly agreed to participate in noninvasive and invasive testing and screening mammography, respectively. The policy makers should notify the importance of demographic factors affecting further examination for early detection of breast cancer in Taiwan.
Kao, Tzu-Jen; Isaacson, David; Saulnier, Gary J.; Newell, Jonathan C.
2009-01-01
The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system. PMID:17405377
Peregrino, Antonio Augusto de Freitas; Vianna, Cid Manso de Mello; de Almeida, Carlos Eduardo Veloso; Gonzáles, Gabriela Bittencourt; Machado, Samara Cristina Ferreira; Costa e Silva, Frances Valéria; Rodrigues, Marcus Paulo da Silva
2012-01-01
A cost-effectiveness analysis was conducted in screening for breast cancer. The use of conventional mammography, digital and magnetic resonance imaging were compared with natural disease history as a baseline. A Markov model projected breast cancer in a group of 100,000 women for a 30 year period, with screening every two years. Four distinct scenarios were modeled: (1) the natural history of breast cancer, as a baseline, (2) conventional film mammography, (3) digital mammography and (4) magnetic resonance imaging. The costs of the scenarios modeled ranged from R$ 194.216,68 for natural history, to R$ 48.614.338,31, for screening with magnetic resonance imaging. The difference in effectiveness between the interventions ranged from 300 to 78.000 years of life gained in the cohort. The ratio of incremental cost-effectiveness in terms of cost per life-year gains, conventional mammographic screening has produced an extra year for R$ 13.573,07. The ICER of magnetic resonance imaging was R$ 2.904.328,88, compared to no screening. In conclusion, it is more cost-effective to perform the screening with conventional mammography than other technological interventions.
Do pre-trained deep learning models improve computer-aided classification of digital mammograms?
NASA Astrophysics Data System (ADS)
Aboutalib, Sarah S.; Mohamed, Aly A.; Zuley, Margarita L.; Berg, Wendie A.; Luo, Yahong; Wu, Shandong
2018-02-01
Digital mammography screening is an important exam for the early detection of breast cancer and reduction in mortality. False positives leading to high recall rates, however, results in unnecessary negative consequences to patients and health care systems. In order to better aid radiologists, computer-aided tools can be utilized to improve distinction between image classifications and thus potentially reduce false recalls. The emergence of deep learning has shown promising results in the area of biomedical imaging data analysis. This study aimed to investigate deep learning and transfer learning methods that can improve digital mammography classification performance. In particular, we evaluated the effect of pre-training deep learning models with other imaging datasets in order to boost classification performance on a digital mammography dataset. Two types of datasets were used for pre-training: (1) a digitized film mammography dataset, and (2) a very large non-medical imaging dataset. By using either of these datasets to pre-train the network initially, and then fine-tuning with the digital mammography dataset, we found an increase in overall classification performance in comparison to a model without pre-training, with the very large non-medical dataset performing the best in improving the classification accuracy.
Si-strip photon counting detectors for contrast-enhanced spectral mammography
NASA Astrophysics Data System (ADS)
Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.
2015-08-01
We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.
Validation of the English and Spanish Mammography Beliefs and Attitudes Questionnaire.
Lopez-McKee, Gloria; Bader, Julia
2011-03-21
Breast cancer is the leading cause of cancer deaths among Hispanic women in the United States. Unfortunately Hispanic women exhibit poor mammography screening participation, are diagnosed at later stages of the disease, and have lower survival rates than non-Hispanic white women. Several cultural and psycho-social factors have been found to influence mammography screening participation among Hispanic women. We will begin by presenting the theoretical framework that grounded this research program to develop an instrument to assess factors contributing to poor mammography participation among Hispanic women. We will also summarize the early stages in the development of the English and Spanish Mammography Beliefs and Attitudes Questionnaire (MBAQ and SMBAQ) for use with low-health-literacy Mexican-American women. Next we will describe the initial psychometric testing of the MBAQ/SMBAQ, after which we will present the psychometric testing of the SMBAQ with low-health-literacy women. This will be followed by a discussion of the modification of the MBAQ and SMBAQ subscales. We'll conclude with a discussion of the instruments and share our assessment regarding the limitations of this research program, where the program stands to date, and the implications for practice and future research.
NASA Astrophysics Data System (ADS)
Kaar, M.; Semturs, F.; Hummel, J.; Hoffmann, R.; Figl, M.
2015-03-01
Technical quality assurance (TQA) procedures for mammography systems usually include tests with a contrast-detail phantom. These phantoms contain multiple objects of varying dimensions arranged on a flat body. Exposures of the phantom are then evaluated by an observer, either human or software. One well-known issue of this method is that dose distribution is not uniform across the image area of any mammography system, mainly due to the heel effect. The purpose of this work is to investigate to what extent image quality differs across the detector plane. We analyze a total of 320 homogeneous mammography exposures from 32 radiology institutes. Systems of different models and manufacturers, both computed radiography (CR) and direct radiography (DR) are included. All images were taken from field installations operated within the nationwide Austrian mammography screening program, which includes mandatory continuous TQA. We calculate signal-to-noise ratios (SNR) for 15 regions of interest arranged to cover the area of the phantom. We define the 'signal range' of an image and compare this value categorized by technologies. We found the deviations of SNR greater in anterior-posterior than in lateral direction. SNR ranges are significantly higher for CR systems than for DR systems.
The evolving role of new imaging methods in breast screening.
Houssami, Nehmat; Ciatto, Stefano
2011-09-01
The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.
76 FR 60848 - National Mammography Quality Assurance Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-30
.../phone line to learn about possible modifications before coming to the meeting. Agenda: On November 4... status of the Full Field Digital Mammography universal quality control manual. FDA intends to make...
Duffy, S W; Mackay, J; Thomas, S; Anderson, E; Chen, T H H; Ellis, I; Evans, G; Fielder, H; Fox, R; Gui, G; Macmillan, D; Moss, S; Rogers, C; Sibbering, M; Wallis, M; Warren, R; Watson, E; Whynes, D; Allgood, P; Caunt, J
2013-03-01
Women with a significant family history of breast cancer are often offered more intensive and earlier surveillance than is offered to the general population in the National Breast Screening Programme. Up to now, this strategy has not been fully evaluated. To evaluate the benefit of mammographic surveillance for women aged 40-49 years at moderate risk of breast cancer due to family history. The study is referred to as FH01. This was a single-arm cohort study with recruitment taking place between January 2003 and February 2007. Recruits were women aged < 50 years with a family history of breast or ovarian cancer conferring at least a 3% risk of breast cancer between ages 40 and 49 years. The women were offered annual mammography for at least 5 years and observed for the occurrence of breast cancer during the surveillance period. The age group 40-44 years was targeted so that they would still be aged < 50 years after 5 years of surveillance. Seventy-four surveillance centres in England, Wales, Scotland and Northern Ireland. A total of 6710 women, 94% of whom were aged < 45 years at recruitment, with a family history of breast cancer estimated to imply at least a 3% risk of the disease between the ages of 40 and 50 years. Annual mammography for at least 5 years. The primary study end point was the predicted risk of death from breast cancer as estimated from the size, lymph node status and grade of the tumours diagnosed. This was compared with the control group from the UK Breast Screening Age Trial (Age Trial), adjusting for the different underlying incidence in the two populations. As of December 2010, there were 165 breast cancers diagnosed in 37,025 person-years of observation and 30,556 mammographic screening episodes. Of these, 122 (74%) were diagnosed at screening. The cancers included 44 (27%) cases of ductal carcinoma in situ. There were 19 predicted deaths in 37,025 person-years in FH01, with an estimated incidence of 6.3 per 1000 per year. The corresponding figures for the Age Trial control group were 204 predicted deaths in 622,127 person-years and an incidence of 2.4 per 1000 per year. This gave an estimated 40% reduction in breast cancer mortality (relative risk = 0.60; 95% confidence interval 0.37 to 0.98; p = 0.04). Annual mammography in women aged 40-49 years with a significant family history of breast or ovarian cancer is both clinically effective in reducing breast cancer mortality and cost-effective. There is a need to further standardise familial risk assessment, to research the impact of digital mammography and to clarify the role of breast density in this population. National Research Register N0484114809. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 11. See the HTA programme website for further project information.
Digital mammography. Why hasn't it been approved for U.S. hospitals?
2000-01-01
Mammography is the only major imaging technique still unavailable in the United States in digital form. This is because the Food and Drug Administration (FDA) has been unable to devise an effective method for manufacturers to demonstrate the safety and efficacy of digital mammography systems. As a result, the agency has been unable to approve any of those systems for marketing in the United States. In this Regulatory Update, we describe FDA's recent efforts to help manufacturers obtain approval and the reasons those efforts have so far proved ineffective.
Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.
Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline
2017-01-01
Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Temporal assessment of radiomic features on clinical mammography in a high-risk population
NASA Astrophysics Data System (ADS)
Mendel, Kayla R.; Li, Hui; Lan, Li; Chan, Chun-Wai; King, Lauren M.; Tayob, Nabihah; Whitman, Gary; El-Zein, Randa; Bedrosian, Isabelle; Giger, Maryellen L.
2018-02-01
Extraction of high-dimensional quantitative data from medical images has become necessary in disease risk assessment, diagnostics and prognostics. Radiomic workflows for mammography typically involve a single medical image for each patient although medical images may exist for multiple imaging exams, especially in screening protocols. Our study takes advantage of the availability of mammograms acquired over multiple years for the prediction of cancer onset. This study included 841 images from 328 patients who developed subsequent mammographic abnormalities, which were confirmed as either cancer (n=173) or non-cancer (n=155) through diagnostic core needle biopsy. Quantitative radiomic analysis was conducted on antecedent FFDMs acquired a year or more prior to diagnostic biopsy. Analysis was limited to the breast contralateral to that in which the abnormality arose. Novel metrics were used to identify robust radiomic features. The most robust features were evaluated in the task of predicting future malignancies on a subset of 72 subjects (23 cancer cases and 49 non-cancer controls) with mammograms over multiple years. Using linear discriminant analysis, the robust radiomic features were merged into predictive signatures by: (i) using features from only the most recent contralateral mammogram, (ii) change in feature values between mammograms, and (iii) ratio of feature values over time, yielding AUCs of 0.57 (SE=0.07), 0.63 (SE=0.06), and 0.66 (SE=0.06), respectively. The AUCs for temporal radiomics (ratio) statistically differed from chance, suggesting that changes in radiomics over time may be critical for risk assessment. Overall, we found that our two-stage process of robustness assessment followed by performance evaluation served well in our investigation on the role of temporal radiomics in risk assessment.
Breast Cancer Risk Prediction and Mammography Biopsy Decisions
Armstrong, Katrina; Handorf, Elizabeth A.; Chen, Jinbo; Demeter, Mirar N. Bristol
2012-01-01
Background Controversy continues about screening mammography, in part because of the risk of false-negative and false-positive mammograms. Pre-test breast cancer risk factors may improve the positive and negative predictive value of screening. Purpose To create a model that estimates the potential impact of pre-test risk prediction using clinical and genomic information on the reclassification of women with abnormal mammograms (BI-RADS3 and BI-RADS4 [Breast Imaging-Reporting and Data System]) above and below the threshold for breast biopsy. Methods The current study modeled 1-year breast cancer risk in women with abnormal screening mammograms using existing data on breast cancer risk factors, 12 validated breast cancer single nucleotide polymorphisms (SNPs), and probability of cancer given the BI-RADS category. Examination was made of reclassification of women above and below biopsy thresholds of 1%, 2%, and 3% risk. The Breast Cancer Surveillance Consortium data were collected from 1996 to 2002. Data analysis was conducted in 2010 and 2011. Results Using a biopsy risk threshold of 2% and the standard risk factor model, 5% of women with a BI-RADS3 mammogram had a risk above the threshold, and 3% of women with BIRADS4A mammograms had a risk below the threshold. The addition of 12 SNPs in the model resulted in 8% of women with a BI-RADS3 mammogram above the threshold for biopsy and 7% of women with BI-RADS4A mammograms below the threshold. Conclusions The incorporation of pre-test breast cancer risk factors could change biopsy decisions for a small proportion of women with abnormal mammograms. The greatest impact comes from standard breast cancer risk factors. PMID:23253645
NASA Astrophysics Data System (ADS)
Ray, Shonket; Keller, Brad M.; Chen, Jinbo; Conant, Emily F.; Kontos, Despina
2016-03-01
This work details a methodology to obtain optimal parameter values for a locally-adaptive texture analysis algorithm that extracts mammographic texture features representative of breast parenchymal complexity for predicting falsepositive (FP) recalls from breast cancer screening with digital mammography. The algorithm has two components: (1) adaptive selection of localized regions of interest (ROIs) and (2) Haralick texture feature extraction via Gray- Level Co-Occurrence Matrices (GLCM). The following parameters were systematically varied: mammographic views used, upper limit of the ROI window size used for adaptive ROI selection, GLCM distance offsets, and gray levels (binning) used for feature extraction. Each iteration per parameter set had logistic regression with stepwise feature selection performed on a clinical screening cohort of 474 non-recalled women and 68 FP recalled women; FP recall prediction was evaluated using area under the curve (AUC) of the receiver operating characteristic (ROC) and associations between the extracted features and FP recall were assessed via odds ratios (OR). A default instance of mediolateral (MLO) view, upper ROI size limit of 143.36 mm (2048 pixels2), GLCM distance offset combination range of 0.07 to 0.84 mm (1 to 12 pixels) and 16 GLCM gray levels was set. The highest ROC performance value of AUC=0.77 [95% confidence intervals: 0.71-0.83] was obtained at three specific instances: the default instance, upper ROI window equal to 17.92 mm (256 pixels2), and gray levels set to 128. The texture feature of sum average was chosen as a statistically significant (p<0.05) predictor and associated with higher odds of FP recall for 12 out of 14 total instances.
Can tailored interventions increase mammography use among HMO women?
Lipkus, I M; Rimer, B K; Halabi, S; Strigo, T S
2000-01-01
Telephone counseling and tailored print communications have emerged as promising methods for promoting mammography screening. However, there has been little research testing, within the same randomized field trial, of the efficacy of these two methods compared to a high-quality usual care system for enhancing screening. This study addressed the question: Compared to usual care, is tailored telephone counseling more effective than tailored print materials for promoting mammography screening? Three-year randomized field trial. One thousand ninety-nine women aged 50 and older recruited from a health maintenance organization in North Carolina. Women were randomized to 1 of 3 groups: (1) usual care, (2) tailored print communications, and (3) tailored telephone counseling. Adherence to mammography screening based on self-reports obtained during 1995, 1996, and 1997. Compared to usual care alone, telephone counseling promoted a significantly higher proportion of women having mammograms on schedule (71% vs 61%) than did tailored print (67% vs 61%) but only after the first year of intervention (during 1996). Furthermore, compared to usual care, telephone counseling was more effective than tailored print materials at promoting being on schedule with screening during 1996 and 1997 among women who were off-schedule during the previous year. The effects of the intervention were most pronounced after the first intervention. Compared to usual care, telephone counseling seemed particularly effective at promoting change among nonadherent women, the group for whom the intervention was developed. These results suggest that telephone counseling, rather than tailored print, might be the preferred first-line intervention for getting nonadherent women on schedule for mammography screening. Many questions would have to be answered about why the tailored print intervention was not more powerful. Nevertheless, it is clear that additional interventions will be needed to maintain women's adherence to mammography. Medical Subject Headings (MeSH): mammography screening, telephone counseling, tailored print communications, barriers.
Schonberg, Mara A; Kistler, Christine E; Nekhlyudov, Larissa; Fagerlin, Angela; Davis, Roger B; Wee, Christina C; Marcantonio, Edward R; Lewis, Carmen L; Stanley, Whitney A; Crutchfield, Trisha M.; Hamel, Mary Beth
2015-01-01
Purpose There is insufficient evidence to recommend mammography for women >75 years. Guidelines recommend that older women be informed of the uncertainty of benefit and potential for harm, especially for women with short life expectancy. However, few older women are informed of harms of screening and many with short life expectancy are screened. Therefore, we aim to test whether a mammography screening decision aid (DA) for women >75 years affects their use of mammography, particularly for women with <10 year life expectancy. Methods/Design The DA is a self-administered pamphlet that includes information on screening outcomes, tailored information on breast cancer risk, health, life expectancy, and competing mortality risks, and includes a values clarification exercise. We are conducting a large cluster randomized controlled trial (RCT) of the DA with the primary care provider (PCP) as the unit of randomization to evaluate its efficacy. We plan to recruit 550 women 75-89 years from 100 PCPs to receive either the mammography DA or a pamphlet on home safety for older adults (control arm) before a visit with their PCP, depending on their PCP's randomization assignment. The primary outcome is receipt of mammography screening assessed through chart abstraction. Secondary outcomes include effect of the DA on older women's screening intentions, knowledge, and decisional conflict, and on documented discussions about mammography by their PCPs. We will recruit women from 5 Boston-based primary care practices (3 community-based internal medicine practices and 2 academic practices), and 2 North Carolina-based academic primary care practices. Discussion It is essential that we test the DA in a large RCT to determine if it is efficacious and to substantiate the need for broad translation into clinical practice. Our DA has the potential to improve health care utilization and care in a manner dictated by patient preferences. PMID:26229741
Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection
Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae
2013-01-01
Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID:23588746
Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda
2018-06-05
Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.
Chen, Yi-Ren; Chang-Halpenny, Christine; Kumarasamy, Narmadan A; Venegas, Angela; Braddock Iii, Clarence H
2016-02-12
Our aim was to examine underserved women's perceptions on mobile versus fixed mammography in Santa Clara, California through a focus group study. Research has shown that medically underserved women have higher breast cancer mortality rates correlated with under-screening and a disproportional rate of late-stage diagnosis. The Community Health Partnership in Santa Clara County, California runs the Community Mammography Access Project (CMAP) that targets nearly 20,000 medically underserved women over the age of 40 in the county through the collaborative effort of an existing safety net of healthcare providers. However, little data exists on the advantages or disadvantages of mobile mammography units from the patient perspective. We assessed underserved women's perspectives on mammography services in Santa Clara County through two focus groups from women screened at mobile or fixed site programs. Patients were recruited from both CMAP clinics and a county hospital, and focus group data were analyzed using content analysis. We found that women from both the mobile and fixed sites shared similar motivating factors for getting a mammogram. Both groups recognized that screening was uncomfortable but necessary for good health and had positive feedback about their personal physicians. However, mobile participants, in particular, appreciated the atmosphere of mobile screening, reported shorter wait times, and remarked on the good communication from the clinic staff and empathetic treatment they received. However, mobile participants also expressed concern about the quality of films at mobile sites due to delayed initial reading of the films. Mobile mammography offers a unique opportunity for women of underserved populations to access high satisfaction screenings, and it encourages a model similar to CMAP in other underserved areas. However, emphasis should be placed on providing a warm and welcoming environment for patients and ensuring the quality of mammography images.
Morris, Elizabeth A.; Kaplan, Jennifer B.; D’Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S.
2017-01-01
Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material–enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board–approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%–76%) and MR imaging (69%–76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55–0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016 PMID:27379544
Screening Ultrasound as an Adjunct to Mammography in Women with Mammographically Dense Breasts
Scheel, John R.; Lee, Janie M.; Sprague, Brian L.; Lee, Christoph I.; Lehman, Constance D.
2015-01-01
There is increasing interest in the potential benefits and harms of screening ultrasound to supplement mammographic screening of women with dense breast tissue. We review the current evidence regarding adjunctive screening breast ultrasound (US) and provide a summary for clinicians who counsel patients with dense breasts. We conducted a comprehensive literature review of published clinical trials and observational cohort studies assessing the efficacy of screening handheld US (HHUS) and automated breast US (ABUS) to supplement mammography among women with dense breasts. From a total of 189 peer-reviewed publications on the performance of screening US, 12 studies were relevant to our analysis. The reporting of breast cancer risk factors varied across studies; however, the study populations tended to be at greater than average risk for developing breast cancer. There is consistent evidence that adjunctive screening US detects more invasive cancers compared to mammography alone, but there is currently no evidence of associated long-term breast cancer mortality reduction. The studies also collectively found that US was associated with an additional 11.7–106.6 biopsies/1,000 examinations (Median 52.2), and detected an additional 0.3–7.7 cancers/1,000 examinations (Median 4.2). The associated number of unnecessary breast biopsies resulting from adjunct US screening exceeds that observed with screening mammography alone by approximately 5-fold. Adjunctive screening with ultrasound should also be considered in the context of screening mammography. It is important for clinicians to be aware that improvements in cancer detection in mammographically dense breasts have been achieved with the transition from film to digital mammography, reducing a limitation of film mammography. Clinicians should discuss breast density as one of several important breast cancer risk factors, consider the potential harms of adjunctive screening, and arrive at a shared decision consistent with each woman’s preferences and values. PMID:24959654
Pisano, Etta D.; Acharyya, Suddhasatta; Cole, Elodia B.; Marques, Helga S.; Yaffe, Martin J.; Blevins, Meredith; Conant, Emily F.; Hendrick, R. Edward; Baum, Janet K.; Fajardo, Laurie L.; Jong, Roberta A.; Koomen, Marcia A.; Kuzmiak, Cherie M.; Lee, Yeonhee; Pavic, Dag; Yoon, Sora C.; Padungchaichote, Wittaya; Gatsonis, Constantine
2009-01-01
Purpose: To determine which factors contributed to the Digital Mammographic Imaging Screening Trial (DMIST) cancer detection results. Materials and Methods: This project was HIPAA compliant and institutional review board approved. Seven radiologist readers reviewed the film hard-copy (screen-film) and digital mammograms in DMIST cancer cases and assessed the factors that contributed to lesion visibility on both types of images. Two multinomial logistic regression models were used to analyze the combined and condensed visibility ratings assigned by the readers to the paired digital and screen-film images. Results: Readers most frequently attributed differences in DMIST cancer visibility to variations in image contrast—not differences in positioning or compression—between digital and screen-film mammography. The odds of a cancer being more visible on a digital mammogram—rather than being equally visible on digital and screen-film mammograms—were significantly greater for women with dense breasts than for women with nondense breasts, even with the data adjusted for patient age, lesion type, and mammography system (odds ratio, 2.28; P < .0001). The odds of a cancer being more visible at digital mammography—rather than being equally visible at digital and screen-film mammography—were significantly greater for lesions imaged with the General Electric digital mammography system than for lesions imaged with the Fischer (P = .0070) and Fuji (P = .0070) devices. Conclusion: The significantly better diagnostic accuracy of digital mammography, as compared with screen-film mammography, in women with dense breasts demonstrated in the DMIST was most likely attributable to differences in image contrast, which were most likely due to the inherent system performance improvements that are available with digital mammography. The authors conclude that the DMIST results were attributable primarily to differences in the display and acquisition characteristics of the mammography devices rather than to reader variability. PMID:19703878
Mammographic density, breast cancer risk and risk prediction
Vachon, Celine M; van Gils, Carla H; Sellers, Thomas A; Ghosh, Karthik; Pruthi, Sandhya; Brandt, Kathleen R; Pankratz, V Shane
2007-01-01
In this review, we examine the evidence for mammographic density as an independent risk factor for breast cancer, describe the risk prediction models that have incorporated density, and discuss the current and future implications of using mammographic density in clinical practice. Mammographic density is a consistent and strong risk factor for breast cancer in several populations and across age at mammogram. Recently, this risk factor has been added to existing breast cancer risk prediction models, increasing the discriminatory accuracy with its inclusion, albeit slightly. With validation, these models may replace the existing Gail model for clinical risk assessment. However, absolute risk estimates resulting from these improved models are still limited in their ability to characterize an individual's probability of developing cancer. Promising new measures of mammographic density, including volumetric density, which can be standardized using full-field digital mammography, will likely result in a stronger risk factor and improve accuracy of risk prediction models. PMID:18190724
Deep learning in mammography and breast histology, an overview and future trends.
Hamidinekoo, Azam; Denton, Erika; Rampun, Andrik; Honnor, Kate; Zwiggelaar, Reyer
2018-07-01
Recent improvements in biomedical image analysis using deep learning based neural networks could be exploited to enhance the performance of Computer Aided Diagnosis (CAD) systems. Considering the importance of breast cancer worldwide and the promising results reported by deep learning based methods in breast imaging, an overview of the recent state-of-the-art deep learning based CAD systems developed for mammography and breast histopathology images is presented. In this study, the relationship between mammography and histopathology phenotypes is described, which takes biological aspects into account. We propose a computer based breast cancer modelling approach: the Mammography-Histology-Phenotype-Linking-Model, which develops a mapping of features/phenotypes between mammographic abnormalities and their histopathological representation. Challenges are discussed along with the potential contribution of such a system to clinical decision making and treatment management. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Costaridou, Lena
Although a wide variety of Computer-Aided Diagnosis (CADx) schemes have been proposed across breast imaging modalities, and especially in mammography, research is still ongoing to meet the high performance CADx requirements. In this chapter, methodological contributions to CADx in mammography and adjunct breast imaging modalities are reviewed, as they play a major role in early detection, diagnosis and clinical management of breast cancer. At first, basic terms and definitions are provided. Then, emphasis is given to lesion content derivation, both anatomical and functional, considering only quantitative image features of micro-calcification clusters and masses across modalities. Additionally, two CADx application examples are provided. The first example investigates the effect of segmentation accuracy on micro-calcification cluster morphology derivation in X-ray mammography. The second one demonstrates the efficiency of texture analysis in quantification of enhancement kinetics, related to vascular heterogeneity, for mass classification in dynamic contrast-enhanced magnetic resonance imaging.
NASA Astrophysics Data System (ADS)
Lee, Donghoon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Choi, Seungyeon; Kim, Hee-Joung
2016-03-01
Breast cancer is one of the most common malignancies in women. For years, mammography has been used as the gold standard for localizing breast cancer, despite its limitation in determining cancer composition. Therefore, the purpose of this simulation study is to confirm the feasibility of obtaining tumor composition using dual energy digital mammography. To generate X-ray sources for dual energy mammography, 26 kVp and 39 kVp voltages were generated for low and high energy beams, respectively. Additionally, the energy subtraction and inverse mapping functions were applied to provide compositional images. The resultant images showed that the breast composition obtained by the inverse mapping function with cubic fitting achieved the highest accuracy and least noise. Furthermore, breast density analysis with cubic fitting showed less than 10% error compare to true values. In conclusion, this study demonstrated the feasibility of creating individual compositional images and capability of analyzing breast density effectively.
Strech, Daniel
2014-03-01
Despite the intensive controversies about the likelihood of benefits and harms of mammography screening almost all experts conclude that the choice to screen or not to screen needs to be made by the individual patient who is adequately informed. However, the "European guideline for quality assurance in breast cancer screening and diagnosis" specifies a participation rate of 70% as the key performance indicator for mammography screening. This paper argues that neither the existing evidence on benefits and harms, nor survey research with women, nor compliance rates in clinical trials, nor cost-effectiveness ratios justify participation rates as a reasonable performance indicator for preference-sensitive condition such as mammography screening. In contrast, an informed choice rate would be more reasonable. Further research needs to address the practical challenges in assessing informed choice rates. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Fancher, Crystal E; Scott, Anthony; Allen, Ahkeel; Dale, Paul
2017-08-01
this is a 10-year retrospective chart review evaluating the potential impact of the most recent American Cancer Society mammography screening guidelines which excludes female patients aged 40 to 44 years from routine annual screening mammography. Instead they recommend screening mammography starting at age 45 with the option to begin screening earlier if the patient desires. The institutional cancer registry was systematically searched to identify all women aged 40 to 44 years treated for breast cancer over a 10-year period. These women were separated into two cohorts: screening mammography detected cancer (SMDC) and nonscreening mammography detected cancer (NSMDC). Statistical analysis of the cohorts was performed for lymph node status (SLN), five-year disease-free survival, and five-year overall survival. Women with SMDC had a significantly lower incidence of SLN positive cancer than the NSMDC group, 9 of 63 (14.3%) versus 36 of 81 (44 %; P < 0.001). The five-year disease-free survival for both groups was 84 per cent for SMDC and 80 per cent for NSMDC; this was not statistically significant. The five-year overall survival was statistically significant at 94 per cent for the SMDC group and 80 per cent for the NSMDC group (P < 0.05). This review demonstrates the significance of mammographic screening for early detection and treatment of breast cancer. Mammographic screening in women aged 40 to 44 detected tumors with fewer nodal metastases, resulting in improved survival and reaffirming the need for annual mammographic screening in this age group.
Chen, Yan; James, Jonathan J; Turnbull, Anne E; Gale, Alastair G
2015-10-01
To establish whether lower resolution, lower cost viewing devices have the potential to deliver mammographic interpretation training. On three occasions over eight months, fourteen consultant radiologists and reporting radiographers read forty challenging digital mammography screening cases on three different displays: a digital mammography workstation, a standard LCD monitor, and a smartphone. Standard image manipulation software was available for use on all three devices. Receiver operating characteristic (ROC) analysis and ANOVA (Analysis of Variance) were used to determine the significance of differences in performance between the viewing devices with/without the application of image manipulation software. The effect of reader's experience was also assessed. Performance was significantly higher (p < .05) on the mammography workstation compared to the other two viewing devices. When image manipulation software was applied to images viewed on the standard LCD monitor, performance improved to mirror levels seen on the mammography workstation with no significant difference between the two. Image interpretation on the smartphone was uniformly poor. Film reader experience had no significant effect on performance across all three viewing devices. Lower resolution standard LCD monitors combined with appropriate image manipulation software are capable of displaying mammographic pathology, and are potentially suitable for delivering mammographic interpretation training. • This study investigates potential devices for training in mammography interpretation. • Lower resolution standard LCD monitors are potentially suitable for mammographic interpretation training. • The effect of image manipulation tools on mammography workstation viewing is insignificant. • Reader experience had no significant effect on performance in all viewing devices. • Smart phones are not suitable for displaying mammograms.
ACR Appropriateness Criteria® Breast Cancer Screening.
Mainiero, Martha B; Moy, Linda; Baron, Paul; Didwania, Aarati D; diFlorio, Roberta M; Green, Edward D; Heller, Samantha L; Holbrook, Anna I; Lee, Su-Ju; Lewin, Alana A; Lourenco, Ana P; Nance, Kara J; Niell, Bethany L; Slanetz, Priscilla J; Stuckey, Ashley R; Vincoff, Nina S; Weinstein, Susan P; Yepes, Monica M; Newell, Mary S
2017-11-01
Breast cancer screening recommendations are based on risk factors. For average-risk women, screening mammography and/or digital breast tomosynthesis is recommended beginning at age 40. Ultrasound (US) may be useful as an adjunct to mammography for incremental cancer detection in women with dense breasts, but the balance between increased cancer detection and the increased risk of a false-positive examination should be considered in the decision. For intermediate-risk women, US or MRI may be indicated as an adjunct to mammography depending upon specific risk factors. For women at high risk due to prior mantle radiation between the ages of 10 to 30, mammography is recommended starting 8 years after radiation therapy but not before age 25. For women with a genetic predisposition, annual screening mammography is recommended beginning 10 years earlier than the affected relative at the time of diagnosis but not before age 30. Annual screening MRI is recommended in high-risk women as an adjunct to mammography. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Amornsiripanitch, Nita; Mangano, Mark; Niell, Bethany L
2017-05-01
Many models exist to estimate a woman's risk of development of breast cancer. At screening mammography, many imaging centers collect data required for these models to identify women who may benefit from supplemental screening and referral for cancer risk assessment. The purpose of this study was to discern perceptions and preferences of screening mammography patients regarding communication of estimated breast cancer risk. An anonymous survey was distributed to screening and surveillance mammography patients between April and June 2015. Survey questions were designed to assess patient preferences regarding the receipt and complexity of risk estimate communication, including hypothetical scenarios with and without > 20% estimated risk of breast cancer. The McNemar test and the Wilcoxon signed rank test were used with p ≤ 0.05 considered statistically significant. The survey was distributed to 1061 screening and surveillance mammography patients, and 503 patients responded (response rate, 47%). Although 86% (431/503) of patients expressed interest in learning their estimated risk, only 8% (38/503) had undergone formal risk assessment. The preferred method (241 respondents [26%]) of communication of risk < 20% was a mailed letter accompanying annual mammogram results. For risk > 20%, patients preferred oral communication and were 10-fold as likely to choose only oral communication (p < 0.000001). For risk < 20% and > 20%, patients preferred to learn their estimated risk in great detail (69% and 85%), although women were significantly more likely to choose greater detail for risk > 20% (p < 0.00001). Screening mammography patients expressed interest in learning their estimated risk of breast cancer regardless of their level of hypothetical risk.
Breast cancer stage at diagnosis: is travel time important?
Henry, Kevin A; Boscoe, Francis P; Johnson, Christopher J; Goldberg, Daniel W; Sherman, Recinda; Cockburn, Myles
2011-12-01
Recent studies have produced inconsistent results in their examination of the potential association between proximity to healthcare or mammography facilities and breast cancer stage at diagnosis. Using a multistate dataset, we re-examine this issue by investigating whether travel time to a patient's diagnosing facility or nearest mammography facility impacts breast cancer stage at diagnosis. We studied 161,619 women 40 years and older diagnosed with invasive breast cancer from ten state population based cancer registries in the United States. For each woman, we calculated travel time to their diagnosing facility and nearest mammography facility. Logistic multilevel models of late versus early stage were fitted, and odds ratios were calculated for travel times, controlling for age, race/ethnicity, census tract poverty, rural/urban residence, health insurance, and state random effects. Seventy-six percent of women in the study lived less than 20 min from their diagnosing facility, and 93 percent lived less than 20 min from the nearest mammography facility. Late stage at diagnosis was not associated with increasing travel time to diagnosing facility or nearest mammography facility. Diagnosis age under 50, Hispanic and Non-Hispanic Black race/ethnicity, high census tract poverty, and no health insurance were all significantly associated with late stage at diagnosis. Travel time to diagnosing facility or nearest mammography facility was not a determinant of late stage of breast cancer at diagnosis, and better geographic proximity did not assure more favorable stage distributions. Other factors beyond geographic proximity that can affect access should be evaluated more closely, including facility capacity, insurance acceptance, public transportation, and travel costs.
Postmortem validation of breast density using dual-energy mammography
Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.
2014-01-01
Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer. PMID:25086548
Postmortem validation of breast density using dual-energy mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun
2014-08-15
Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decompositionmore » was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.« less
Wallington, Sherrie Flynt; Oppong, Bridget; Iddirisu, Marquita; Adams-Campbell, Lucile L
2017-12-26
This study developed and examined the reach and impact of a culturally appropriate mass media campaign pilot, designed to increase awareness about the importance of mammography screening and the available community mammography services for low-income African American women ages 40 and above. We conducted formative research using focus groups to inform campaign development, resulting in five emergent themes-good breast health, holistic views of healthiness, cancer fatalism, fear of mammogram machines, and mammogram affordability. The campaign targeted specific low-income African American communities in the District of Columbia via print ads in Metro stations and on buses, print ads in the Washington Informer, and online ads on a local TV network website. Data were collected before, during, and after campaign implementation to assess reach and impact. Reach was measured by number of impressions (number of people exposed to the campaign), while impact was assessed via online ad click-through rates, website use and referrals, and mammography center calls. The campaign was successful in reaching the target audience, with a total combined reach from all media of 9,479,386 impressions. In addition, the mammography center received significant increases in new website visitors (1482 during the campaign, compared to 24 during the preceding period) as well as 97 calls to the dedicated phone line. Further research involving a more long-term investment in terms of funding and campaign run time, coupled with a more robust evaluation, is needed to assess if culturally appropriate mass media campaigns can generate increased mammography screening rates and decrease breast-cancer-related mortality.
Hauser, Nik; Wang, Zhentian; Kubik-Huch, Rahel A; Trippel, Mafalda; Singer, Gad; Hohl, Michael K; Roessl, Ewald; Köhler, Thomas; van Stevendaal, Udo; Wieberneit, Nataly; Stampanoni, Marco
2014-03-01
Differential phase contrast and scattering-based x-ray mammography has the potential to provide additional and complementary clinically relevant information compared with absorption-based mammography. The purpose of our study was to provide a first statistical evaluation of the imaging capabilities of the new technique compared with digital absorption mammography. We investigated non-fixed mastectomy samples of 33 patients with invasive breast cancer, using grating-based differential phase contrast mammography (mammoDPC) with a conventional, low-brilliance x-ray tube. We simultaneously recorded absorption, differential phase contrast, and small-angle scattering signals that were combined into novel high-frequency-enhanced images with a dedicated image fusion algorithm. Six international, expert breast radiologists evaluated clinical digital and experimental mammograms in a 2-part blinded, prospective independent reader study. The results were statistically analyzed in terms of image quality and clinical relevance. The results of the comparison of mammoDPC with clinical digital mammography revealed the general quality of the images to be significantly superior (P < 0.001); sharpness, lesion delineation, as well as the general visibility of calcifications to be significantly more assessable (P < 0.001); and delineation of anatomic components of the specimens (surface structures) to be significantly sharper (P < 0.001). Spiculations were significantly better identified, and the overall clinically relevant information provided by mammoDPC was judged to be superior (P < 0.001). Our results demonstrate that complementary information provided by phase and scattering enhanced mammograms obtained with the mammoDPC approach deliver images of generally superior quality. This technique has the potential to improve radiological breast diagnostics.
AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil
2015-03-01
The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Quality assurance and quality control in mammography: a review of available guidance worldwide.
Reis, Cláudia; Pascoal, Ana; Sakellaris, Taxiarchis; Koutalonis, Manthos
2013-10-01
Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources. •An effective QA program should be practical to implement in a clinical setting. •QA should address the various stages of the imaging chain: acquisition, processing and display. •AEC system QC testing is simple to implement and provides information on equipment performance.
Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S
2011-04-01
Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Heine, John J.; Wollin, Ernest
2015-03-01
A new technique is proposed and experimentally validated for breast cancer detection and diagnosis. The technique combines magnetic resonance with electrical impedance measurements and has the potential to increase the specificity of magnetic resonance mammography (MRM) thereby reducing false positive biopsy rates. The new magnetic resonance electrical impedance mammography (MREIM) adds a time varying electric field during a supplementary sequence to a standard MRM examination with an apparatus that is "invisible" to the patient. The applied electric field produces a current that creates an additional magnetic field with a component aligned with the bore magnetic field that can alter the native signal in areas of higher electrical conductivity. The justification for adding the electric field is that the electrical conductivity of cancerous breast tissue is approximately 3-40 times higher than normal breast tissue and, hence, conductivity of malignant tissue represents a known clinical disease biomarker. In a pilot study with custom-made phantoms and experimental protocols, it was demonstrated that MREIM can produce, as theoretically predicted, a detectable differential signal in areas of higher electrical conductivity (tumor surrogate regions); the evidence indicates that the differential signal is produced by the confluence of two different effects at full image resolution without gadolinium chelate contrast agent injection, without extraneous reconstruction techniques, and without cumbersome multi-positioned patient electrode configurations. This paper describes the theoretical model that predicts and explains the observed experimental results that were also confirmed by simulation studies.
Predictive features of breast cancer on Mexican screening mammography patients
NASA Astrophysics Data System (ADS)
Rodriguez-Rojas, Juan; Garza-Montemayor, Margarita; Trevino-Alvarado, Victor; Tamez-Pena, José Gerardo
2013-02-01
Breast cancer is the most common type of cancer worldwide. In response, breast cancer screening programs are becoming common around the world and public programs now serve millions of women worldwide. These programs are expensive, requiring many specialized radiologists to examine all images. Nevertheless, there is a lack of trained radiologists in many countries as in Mexico, which is a barrier towards decreasing breast cancer mortality, pointing at the need of a triaging system that prioritizes high risk cases for prompt interpretation. Therefore we explored in an image database of Mexican patients whether high risk cases can be distinguished using image features. We collected a set of 200 digital screening mammography cases from a hospital in Mexico, and assigned low or high risk labels according to its BIRADS score. Breast tissue segmentation was performed using an automatic procedure. Image features were obtained considering only the segmented region on each view and comparing the bilateral di erences of the obtained features. Predictive combinations of features were chosen using a genetic algorithms based feature selection procedure. The best model found was able to classify low-risk and high-risk cases with an area under the ROC curve of 0.88 on a 150-fold cross-validation test. The features selected were associated to the differences of signal distribution and tissue shape on bilateral views. The model found can be used to automatically identify high risk cases and trigger the necessary measures to provide prompt treatment.
Poorolajal, Jalal; Akbari, Mohammad Esmaeil; Ziaee, Fatane; Karami, Manoochehr; Ghoncheh, Mahshid
2017-05-15
The breast cancer screening (BCS) chart is suggested as a basic and preliminary tool to improve efficiency of screening mammography. We conducted this case-control study in 2016 and enrolled 1422 women aged 30-75 years, including 506 women with breast cancer (cases) and 916 women without breast cancer (controls). We developed the BCS chart using a multiple logistic regression analysis. We combined the risks of breast cancer to predict the individual risk of breast cancer. Then, we stratified and colored the predicted risk probabilities as follows: <05% (green), 05-09% (yellow), 10-14% (orange), 15-19% (red), 20-24% (brown) and ≥25% (black). The BCS chart provides the risk probability of breast cancer, based on age, body mass index, late menopause, having a benign breast disease and a positive family history of breast cancer among the first-degree or the second/third-degree relatives. According to this chart, an individual can be classified in a category of low risk (green), medium risk (yellow and orange), high risk (red and brown) and very high risk (black) for breast cancer. This chart is a flexible and easy to use tool that can detect high-risk subjects and make the screening program more efficient and productive. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
21 CFR 900.12 - Quality standards.
Code of Federal Regulations, 2014 CFR
2014-04-01
... to mammography. The training shall include instruction in radiation physics, including radiation physics specific to mammography, radiation effects, and radiation protection. The mammographic... ensure that medical physicists certified by the body are competent to perform physics survey; and (B)(1...
21 CFR 900.12 - Quality standards.
Code of Federal Regulations, 2013 CFR
2013-04-01
... to mammography. The training shall include instruction in radiation physics, including radiation physics specific to mammography, radiation effects, and radiation protection. The mammographic... ensure that medical physicists certified by the body are competent to perform physics survey; and (B)(1...
21 CFR 900.12 - Quality standards.
Code of Federal Regulations, 2012 CFR
2012-04-01
... to mammography. The training shall include instruction in radiation physics, including radiation physics specific to mammography, radiation effects, and radiation protection. The mammographic... ensure that medical physicists certified by the body are competent to perform physics survey; and (B)(1...
21 CFR 900.12 - Quality standards.
Code of Federal Regulations, 2011 CFR
2011-04-01
... to mammography. The training shall include instruction in radiation physics, including radiation physics specific to mammography, radiation effects, and radiation protection. The mammographic... ensure that medical physicists certified by the body are competent to perform physics survey; and (B)(1...
Pictorial essay: Mammography of the male breast
Popli, Manju Bala; Popli, V; Bahl, P; Solanki, Y
2009-01-01
Mammography is an imaging modality that is widely perceived to be of use only in women for the detection and diagnosis of breast pathologies. Here, we present a pictorial essay on the mammographic spectrum of male breast pathologies. PMID:19881102
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, Lincoln J.; Samei, Ehsan; Lo, Joseph Y.
2011-04-15
Purpose: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography?more » The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. Methods: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 deg. using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. Results: The mean AUC for the five observers was 0.614{+-}0.055 for mammography and 0.778{+-}0.052 for multiview stereoscopy. The difference of 0.164{+-}0.065 was statistically significant with a p-value of 0.0148. Conclusions: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.« less
Miller, Jeffrey D; Bonafede, Machaon M; Herschorn, Sally D; Pohlman, Scott K; Troeger, Kathleen A; Fajardo, Laurie L
2017-04-01
Better understanding regarding the clinical-economic value of digital breast tomosynthesis (DBT) for breast cancer screening for Medicaid enrollees is needed to help inform sound, value-based decision making. The objective of this study was to conduct a clinical-economic value analysis of DBT for breast cancer screening among women enrolled in Medicaid to assess the potential clinical benefits, associated expenditures, and net budget impact of DBT. Two annual screening mammography scenarios were evaluated with an economic model: (1) full-field digital mammography and (2) combined full-field digital mammography and DBT. The model focused on two main drivers of DBT value: (1) capacity for DBT to reduce the number of women recalled for additional follow-up imaging and diagnostic services and (2) capacity of DBT to facilitate earlier diagnosis of cancer at earlier stages, when treatment costs are lower. Model analysis results showed that the use of DBT as a mammographic screening modality by Medicaid enrollees potentially reduces the need for follow-up diagnostic services and improves the detection of invasive cancers, allowing earlier, less costly treatment. With the modest incremental reimbursement of $37 for DBT expected for a typical Medicaid claim, annual cost savings from DBT predicted by the model amounts to $8.14 per patient, potentially translating into more than $12,000 savings per year for an average-sized Medicaid plan and as much as $207,000 savings per year for a typical state Medicaid program. Wider adoption of DBT presents an opportunity to deliver value-based care to Medicaid programs and to help address disparities and barriers to accessing preventive care by some of the nation's most vulnerable citizens. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Shieh, Yiwey; Eklund, Martin; Madlensky, Lisa; Sawyer, Sarah D; Thompson, Carlie K; Stover Fiscalini, Allison; Ziv, Elad; Van't Veer, Laura J; Esserman, Laura J; Tice, Jeffrey A
2017-01-01
Ongoing controversy over the optimal approach to breast cancer screening has led to discordant professional society recommendations, particularly in women age 40 to 49 years. One potential solution is risk-based screening, where decisions around the starting age, stopping age, frequency, and modality of screening are based on individual risk to maximize the early detection of aggressive cancers and minimize the harms of screening through optimal resource utilization. We present a novel approach to risk-based screening that integrates clinical risk factors, breast density, a polygenic risk score representing the cumulative effects of genetic variants, and sequencing for moderate- and high-penetrance germline mutations. We demonstrate how thresholds of absolute risk estimates generated by our prediction tools can be used to stratify women into different screening strategies (biennial mammography, annual mammography, annual mammography with adjunctive magnetic resonance imaging, defer screening at this time) while informing the starting age of screening for women age 40 to 49 years. Our risk thresholds and corresponding screening strategies are based on current evidence but need to be tested in clinical trials. The Women Informed to Screen Depending On Measures of risk (WISDOM) Study, a pragmatic, preference-tolerant randomized controlled trial of annual vs personalized screening, will study our proposed approach. WISDOM will evaluate the efficacy, safety, and acceptability of risk-based screening beginning in the fall of 2016. The adaptive design of this trial allows continued refinement of our risk thresholds as the trial progresses, and we discuss areas where we anticipate emerging evidence will impact our approach. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Information Extraction for Clinical Data Mining: A Mammography Case Study
Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David
2013-01-01
Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts’ input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F1-score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level. PMID:23765123
Information Extraction for Clinical Data Mining: A Mammography Case Study.
Nassif, Houssam; Woods, Ryan; Burnside, Elizabeth; Ayvaci, Mehmet; Shavlik, Jude; Page, David
2009-01-01
Breast cancer is the leading cause of cancer mortality in women between the ages of 15 and 54. During mammography screening, radiologists use a strict lexicon (BI-RADS) to describe and report their findings. Mammography records are then stored in a well-defined database format (NMD). Lately, researchers have applied data mining and machine learning techniques to these databases. They successfully built breast cancer classifiers that can help in early detection of malignancy. However, the validity of these models depends on the quality of the underlying databases. Unfortunately, most databases suffer from inconsistencies, missing data, inter-observer variability and inappropriate term usage. In addition, many databases are not compliant with the NMD format and/or solely consist of text reports. BI-RADS feature extraction from free text and consistency checks between recorded predictive variables and text reports are crucial to addressing this problem. We describe a general scheme for concept information retrieval from free text given a lexicon, and present a BI-RADS features extraction algorithm for clinical data mining. It consists of a syntax analyzer, a concept finder and a negation detector. The syntax analyzer preprocesses the input into individual sentences. The concept finder uses a semantic grammar based on the BI-RADS lexicon and the experts' input. It parses sentences detecting BI-RADS concepts. Once a concept is located, a lexical scanner checks for negation. Our method can handle multiple latent concepts within the text, filtering out ultrasound concepts. On our dataset, our algorithm achieves 97.7% precision, 95.5% recall and an F 1 -score of 0.97. It outperforms manual feature extraction at the 5% statistical significance level.
Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.
Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M
2012-07-01
Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.
April-Sanders, Ayana; Oskar, Sabine; Shelton, Rachel C; Schmitt, Karen M; Desperito, Elise; Protacio, Angeline; Tehranifar, Parisa
Worry about developing breast cancer (BC) has been associated with participation in screening and genetic testing and with follow-up of abnormal screening results. Little is known about the scope and predictors of BC worry in Hispanic and immigrant populations. We collected in-person interview data from 250 self-identified Hispanic women recruited from an urban mammography facility (average age 50.4 years; 82% foreign-born). Women reported whether they worried about developing breast cancer rarely/never (low worry), sometimes (moderate worry), or often/all the time (high worry). We examined whether sociocultural and psychological factors (e.g., acculturation, education, perceived risk), and risk factors and objective risk for BC (e.g., family history, Gail model 5-year risk estimates, parity) predicted BC worry using multinomial and logistic regression. In multivariable models, women who perceived higher absolute BC risk (odds ratio, 1.66 [95% confidence interval, 1.28-2.14] for a one-unit increase in perceived lifetime risk) and comparative BC risk (e.g., odds ratio, 2.73, 95% confidence interval, 1.23-6.06) were more likely to report high BC worry than moderate or low BC worry. There were no associations between BC worry and indicators of objective risk or acculturation. In Hispanic women undergoing screening mammography, higher perceptions of BC risk, in both absolute and comparative terms, were associated independently with high BC worry, and were stronger predictors of BC worry than indicators of objective BC risk, including family history, mammographic density, and personal BC risk estimates. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.
2-D or 3-D Mammography? The Future of Breast Cancer Detection
... D or 3-D Mammography?: The Future of Breast Cancer Detection NIH-supported clinical trial tests diagnostic imaging ... new trial may be the answer for finding breast cancer in women who don’t have symptoms. The ...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
Hellerhoff, K
2010-11-01
In recent years digital full field mammography has increasingly replaced conventional film mammography. High quality imaging is guaranteed by high quantum efficiency and very good contrast resolution with optimized dosing even for women with dense glandular tissue. However, digital mammography remains a projection procedure by which overlapping tissue limits the detectability of subtle alterations. Tomosynthesis is a procedure developed from digital mammography for slice examination of breasts which eliminates the effects of overlapping tissue and allows 3D imaging of breasts. A curved movement of the X-ray tube during scanning allows the acquisition of many 2D images from different angles. Subseqently, reconstruction algorithms employing a shift and add method improve the recognition of details at a defined level and at the same time eliminate smear artefacts due to overlapping structures. The total dose corresponds to that of conventional mammography imaging. The technical procedure, including the number of levels, suitable anodes/filter combinations, angle regions of images and selection of reconstruction algorithms, is presently undergoing optimization. Previous studies on the clinical value of tomosynthesis have examined screening parameters, such as recall rate and detection rate as well as information on tumor extent for histologically proven breast tumors. More advanced techniques, such as contrast medium-enhanced tomosynthesis, are presently under development and dual-energy imaging is of particular importance.
Della Sala, W; Tognotti, F; Pellegrini, M; Bernardi, D; Gentilini, M; Piffer, S
2005-01-01
Present paper reports on the results of a pilot customer satisfaction study carried out on 1.720 consecutive women (18.7 with spontaneous access) attended senology department (Trento and Borgo) in the context of a organized mammography screening programme, started in October 2000. Data were collected by a questionnarie filled by the women after mammography. 4.3% of the invited women reported the receiving the letter late, 0.9% considered it inaccurate, 7.2% had some problems for getting a new date for test, 1.8% of the whole sample reported some problems for external access and 2.2% for internal access to health facilities; 1.9% perceived waiting room as not friendly. The welcoming by the personnel is judged quite well, only 0.6% complained about it. Trento centre, is more efficient than Borgo. In 21.7% of the cases the mammography has been performed within next 30 minutes of the fixed time and in 7.9% besides that. 36.8% of the whole sample perceived mammography as tiresome and 4.1% as painful. The percentage of women reporting mammography disconforting increase, in Trento sample, according the education level as previously reported. The data about perceived quality are satisfactory, on the whole. Anyway it would be opportune to contain the waiting time.
Cost-effectiveness comparison of five interventions to increase mammography screening.
Saywell, R M; Champion, V L; Skinner, C S; McQuillen, D; Martin, D; Maraj, M
1999-11-01
Mammography is the primary method used for breast cancer screening. However, compliance with recommended screening practices is still below acceptable levels. This study examined the cost-effectiveness of five combinations of physician recommendation and telephone or in-person individualized counseling strategies for increasing compliance with mammography. There were 808 participants who were randomly assigned to one of six groups. A logistic regression model with compliance as the dependent variable and group as the independent variable was used to test for significant differences and a ratio of cost to improvement in mammogram compliance evaluated the cost-effectiveness. Three of the interventions (in-person, telephone plus letter, and in-person plus letter) had significantly better compliance rates compared with the control, physician letter, or telephone alone. However, when considering costs, only one emerged as the superior strategy. The cost-effectiveness ratios for the five interventions show that telephone-plus-letter is the most cost-effective strategy, achieving a 35.6% mammography compliance at a marginal cost of $0.78 per 1% increase in women screened. A tailored phone prompt and physician reminder is an effective and economical intervention to increase mammography. Future research should confirm this finding and address its applicability to practice. Copyright 1999 American Health Foundation and Academic Press.
Mammography screening trends: the perspective of African American women born pre/post World War II.
Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A
2010-06-01
Researchers have traditionally combined aging women (aged > or =50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non-baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non-baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947-0.968) cohort effects may have partially reversed the age effect, with non-baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278-2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population.
Krammer, Julia; Stepniewski, Kathrin; Kaiser, Clemens G; Brade, Joachim; Riffel, Philipp; Schoenberg, Stefan O; Wasser, Klaus
2017-09-01
This retrospective study was initiated to determine the diagnostic value of additional preoperative breast tomosynthesis (DBT) for breast cancer staging in dense breasts. Sixty-six patients (69 breasts) with findings of American College of Radiology category 3 or 4 with Breast Imaging Reporting and Data System 5, 6 or 0 were included. All patients underwent digital mammography and additional DBT. A total of 40/69 (58%) cancers were detected on both mammography and DBT, 23 (33.3%) were only seen on DBT (p=0.0001); 6/69 (8.7%) carcinomas were not detected by either method, of which three were invasive lobular carcinomas. Sensitivity for multifocal/multicentric disease was significantly higher on DBT (12/19, 63.2%) compared to mammography (4/19, 21.1%) (p=0.02), specificity was comparable (96.0% vs. 90.0%). Multifocal/multicentric disease was not detected on mammography nor DBT in 7/19 (36.8%) patients, including three invasive lobular carcinomas. DBT may significantly improve preoperative breast cancer staging in patients with dense breasts compared to conventional mammography alone. Nevertheless, limitations have to be expected in the case of invasive lobular carcinoma. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Barriers and incentives for choosing to specialise in mammography: Qualitative analysis.
Warren-Forward, H M; Taylor, J
2017-02-01
There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Imaging Surveillance After Primary Breast Cancer Treatment
Lam, Diana L.; Houssami, Nehmat; Lee, Janie M.
2017-01-01
OBJECTIVE Current clinical guidelines are consistent in supporting annual mammography for women after treatment of primary breast cancer. Surveillance imaging beyond standard digital mammography, including digital breast tomosynthesis (DBT), breast ultrasound, and MRI, may improve outcomes. This article reviews the evidence on the performance and effectiveness of breast imaging modalities available for surveillance after treatment of sporadic unilateral primary breast cancer and identifies additional factors to be considered when selecting an imaging surveillance regimen. CONCLUSION Evidence review supports the use of mammography for surveillance after primary breast cancer treatment. Variability exists in guideline recommendations for surveillance initiation, interval, and cessation. DBT offers the most promise as a potential modality to replace standard digital mammography as a front-line surveillance test; a single published study to date has shown a significant decrease in recall rates compared with standard digital mammography alone. Most guidelines do not support the use of whole-breast ultrasound in breast cancer surveillance, and further studies are needed to define the characteristics of women who may benefit from MRI surveillance. The emerging evidence about surveillance imaging outcomes suggests that additional factors, including patient and imaging characteristics, tumor biology and gene expression profile, and choice of treatment, warrant consideration in selecting personalized posttreatment imaging surveillance regimens. PMID:28075622
Autier, P; Ouakrim, D A
2008-01-01
In the 2000s, most of the female population of industrialised countries had access to mammography breast cancer screening, but with variable modalities among the countries. We assessed the number of mammography units (MUs) in 31 European, North American and Asian countries where significant mammography activity has existed for over 10 years, collecting data on the number of such units and of radiologists by contacting institutions in each country likely to provide the relevant information. Around 2004, there were 32 324 MU in 31 countries, the number per million women ranging from less than 25 in Turkey, Denmark, the Netherlands, the United Kingdom, Norway, Poland and Hungary to more than 80 in Cyprus, Italy, France, the United States and Austria. In a multivariate analysis, the number of MUs was positively associated with the number of radiologists (P=0.0081), the number of women (P=0.0023) and somewhat with the country surface area (P=0.077). There is considerable variation in the density of MU across countries and the number of MUs in service are often well above what would be necessary according to local screening recommendations. High number of MUs in some countries may have undesirable consequences, such as unnecessarily high screening frequency and decreased age at which screening is started. PMID:18781176
Optical tomography as adjunct to x-ray mammography: methods and results
NASA Astrophysics Data System (ADS)
Khayat, Mario; Ichalalene, Zahia; Mincu, Niculae; Leblond, Fredéric; Guilman, Olga; Djeziri, Salim
2007-02-01
Recent years have seen significant efforts deployed to apply optical imaging techniques in clinical indications. Optical mammography as an adjunct to X-ray mammography is one such application. 3D optical mammography relies on the sensitivity of near-infrared light to endogenous breast chromophores in order to generate in vivo functional views of the breast. This work presents prospective tissue characterization results from a multi-site clinical study targeting optical tomography as an adjunct to conventional mammography. A 2 nd -generation multi-wavelength time-domain acquisition system was used to scan a wide population of women presenting normal or suspicious X-ray mammograms. Application specific algorithms based on a diffusive model of light transport were used to quantify the breast's optical properties and derive 3D images of physiological indices. Using histopathological findings as a gold standard, results confirm that optically derived parameters provide statistically significant discrimination between malignant and benign tissue in wide population of subjects. The methodology developed for case reviews, lesion delineation and characterization allows for better translation of the optical data to the more traditional x-ray paradigm while maintaining efficacy. They also point to the need for guidelines that facilitate correlation of optical data if those results are to be confirmed in a clinical setting.
Simulation of breast compression in mammography using finite element analysis: A preliminary study
NASA Astrophysics Data System (ADS)
Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay
2017-11-01
Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.
Social and Cultural Meanings of Self-Efficacy
Burke, Nancy J.; Bird, Joyce A.; Clark, Melissa A.; Rakowski, William; Guerra, Claudia; Barker, Judith C.; Pasick, Rena J.
2010-01-01
This article describes the influences of social context on women’s health behavior through illustration of the powerful influences of social capital (the benefits and challenges that accrue from participation in social networks and groups) on experiences and perceptions of self-efficacy. The authors conducted inductive interviews with Latino and Filipino academics and social service providers and with U.S.-born and immigrant Latinas and Filipinas to explore direct and indirect influences of social context on health behaviors such as mammography screening. Iterative thematic analysis identified themes (meanings of efficacy, spheres of efficacy, constraints on efficacy, sources of social capital, and differential access to and quality of social capital) that link the domain of social capital with the behavioral construct perceived self-efficacy. The authors conclude that social capital addresses aspects of social context absent in the current self-efficacy construct and that these aspects have important implications for scholars’ and practitioners’ understandings of health behavior and intervention development. PMID:19805794
Impact of different study populations on reader behavior and performance metrics: initial results
NASA Astrophysics Data System (ADS)
Gallas, Brandon D.; Pisano, Etta; Cole, Elodia; Myers, Kyle
2017-03-01
The FDA recently completed a study on design methodologies surrounding the Validation of Imaging Premarket Evaluation and Regulation called VIPER. VIPER consisted of five large reader sub-studies to compare the impact of different study populations on reader behavior as seen by sensitivity, specificity, and AUC, the area under the ROC curve (receiver operating characteristic curve). The study investigated different prevalence levels and two kinds of sampling of non-cancer patients: a screening population and a challenge population. The VIPER study compared full-field digital mammography (FFDM) to screenfilm mammography (SFM) for women with heterogeneously dense or extremely dense breasts. All cases and corresponding images were sampled from Digital Mammographic Imaging Screening Trial (DMIST) archives. There were 20 readers (American Board Certified radiologists) for each sub-study, and instead of every reader reading every case (fully-crossed study), readers and cases were split into groups to reduce reader workload and the total number of observations (split-plot study). For data collection, readers first decided whether or not they would recall a patient. Following that decision, they provided an ROC score for how close or far that patient was from the recall decision threshold. Performance results for FFDM show that as prevalence increases to 50%, there is a moderate increase in sensitivity and decrease in specificity, whereas AUC is mainly flat. Regarding precision, the statistical efficiency (ratio of variances) of sensitivity and specificity relative to AUC are 0.66 at best and decrease with prevalence. Analyses comparing modalities and the study populations (screening vs. challenge) are still ongoing.
Impact of Different Study Populations on Reader Behavior and Performance Metrics: Initial Results
Gallas, Brandon D.; Pisano, Etta; Cole, Elodia; Myers, Kyle
2017-01-01
The FDA recently completed a study on design methodologies surrounding the Validation of Imaging Premarket Evaluation and Regulation called VIPER. VIPER consisted of five large reader sub-studies to compare the impact of different study populations on reader behavior as seen by sensitivity, specificity, and AUC, the area under the ROC curve (receiver operating characteristic curve). The study investigated different prevalence levels and two kinds of sampling of non-cancer patients: a screening population and a challenge population. The VIPER study compared full-field digital mammography (FFDM) to screen-film mammography (SFM) for women with heterogeneously dense or extremely dense breasts. All cases and corresponding images were sampled from Digital Mammographic Imaging Screening Trial (DMIST) archives. There were 20 readers (American Board Certified radiologists) for each sub-study, and instead of every reader reading every case (fully-crossed study), readers and cases were split into groups to reduce reader workload and the total number of observations (split-plot study). For data collection, readers first decided whether or not they would recall a patient. Following that decision, they provided an ROC score for how close or far that patient was from the recall decision threshold. Performance results for FFDM show that as prevalence increases to 50%, there is a moderate increase in sensitivity and decrease in specificity, whereas AUC is mainly flat. Regarding precision, the statistical efficiency (ratio of variances) of sensitivity and specificity relative to AUC are 0.66 at best and decrease with prevalence. Analyses comparing modalities and the study populations (screening vs. challenge) are still ongoing. PMID:28845078
21 CFR 900.3 - Application for approval as an accreditation body.
Code of Federal Regulations, 2011 CFR
2011-04-01
... SERVICES (CONTINUED) MAMMOGRAPHY QUALITY STANDARDS ACT MAMMOGRAPHY Accreditation § 900.3 Application for... Internal Revenue Service requirements as a nonprofit organization); (ii) Detailed description of the... that the applicant develops, sells, or distributes; (xi) Description of the applicant's consumer...
21 CFR 900.3 - Application for approval as an accreditation body.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SERVICES (CONTINUED) MAMMOGRAPHY QUALITY STANDARDS ACT MAMMOGRAPHY Accreditation § 900.3 Application for... Internal Revenue Service requirements as a nonprofit organization); (ii) Detailed description of the... that the applicant develops, sells, or distributes; (xi) Description of the applicant's consumer...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false [Reserved] 900.17 Section 900.17 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MAMMOGRAPHY QUALITY STANDARDS ACT MAMMOGRAPHY Quality Standards and Certification § 900.17 [Reserved] ...
TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, H; Cho, H; Kumar, N
Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low-more » and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.« less
Screening Mammography for Free: Impact of Eliminating Cost Sharing on Cancer Screening Rates.
Jena, Anupam B; Huang, Jie; Fireman, Bruce; Fung, Vicki; Gazelle, Scott; Landrum, Mary Beth; Chernew, Michael; Newhouse, Joseph P; Hsu, John
2017-02-01
To study the impact of eliminating cost sharing for screening mammography on mammography rates in a large Medicare Advantage (MA) health plan which in 2010 eliminated cost sharing in anticipation of the Affordable Care Act mandate. Large MA health maintenance organization offering individual-subscriber MA insurance and employer-supplemented group MA insurance. We investigated the impact on breast cancer screening of a policy that eliminated a $20 copayment for screening mammography in 2010 among 53,188 women continuously enrolled from 2007 to 2012 in an individual-subscriber MA plan, compared with 42,473 women with employer-supplemented group MA insurance in the same health maintenance organization who had full screening coverage during this period. We used differences-in-differences analysis to study the impact of cost-sharing elimination on mammography rates. Annual screening rates declined over time for both groups, with similar trends pre-2010 and a slower decline after 2010 among women whose copayments were eliminated. Among women aged 65-74 years in the individual-subscriber MA plan, 44.9 percent received screening in 2009 compared with 40.9 percent in 2012, while 49.5 percent of women in the employer-supplemented MA plan received screening in 2009 compared with 44.1 percent in 2012, that is, a difference-in-difference effect of 1.4 percentage points less decline in screening among women experiencing the cost-sharing elimination. Effects were concentrated among women without recent screening. There were no differences by neighborhood socioeconomic status or race/ethnicity. Eliminating cost sharing for screening mammography was associated with modesty lower decline in screening rates among women with previously low screening adherence. © Health Research and Educational Trust.
Detroit's avoidable mortality project: breast cancer control for inner-city women.
Burack, R C; Gimotty, P A; Stengle, W; Eckert, D; Warbasse, L; Moncrease, A
1989-01-01
Mammography remains substantially under-used in low-income minority populations despite its well-established efficacy as a means of breast cancer control. The Metropolitan Detroit Avoidable Mortality Project is a 2-year controlled clinical trial of coordinated interventions which seek to improve the use of early breast cancer detection services at five clinical sites providing primary health care services to inner-city women. Baseline assessment for two of the five participating clinic populations demonstrated that only one-quarter of women who visited these clinics were referred for mammography in 1988, and only half of those who were referred were able to complete the procedure. Patient characteristics including age, marital status, ethnicity, and insurance status were not associated with use of mammography during the baseline period. Each of the project's intervention components is a cue to action: a physician prompt for mammography referral within the medical record of procedure-due women, a reminder postcard for scheduled appointments, and a telephone call to encourage rescheduling of missed appointments. The interventions are initiated by a computerized information management system in the existing network of health care services. The patient's out-of-pocket mammography expense has been eliminated in three of the five sites. Although their efficacy as individual interventions has been well established, a controlled trial of computer prompts to physicians, reduced expense for patients, and patient appointment reminders as an integrated system in inner-city medical care settings has not been previously described. We have implemented the prompting, facilitated rescheduling procedures, and eliminated patient expense for mammography at three of five eventual clinical sites. This report provides an overview of the study's design, data management system, and methodology for evaluation. PMID:2511584
Comas, Mercè; Arrospide, Arantzazu; Mar, Javier; Sala, Maria; Vilaprinyó, Ester; Hernández, Cristina; Cots, Francesc; Martínez, Juan; Castells, Xavier
2014-01-01
To assess the budgetary impact of switching from screen-film mammography to full-field digital mammography in a population-based breast cancer screening program. A discrete-event simulation model was built to reproduce the breast cancer screening process (biennial mammographic screening of women aged 50 to 69 years) combined with the natural history of breast cancer. The simulation started with 100,000 women and, during a 20-year simulation horizon, new women were dynamically entered according to the aging of the Spanish population. Data on screening were obtained from Spanish breast cancer screening programs. Data on the natural history of breast cancer were based on US data adapted to our population. A budget impact analysis comparing digital with screen-film screening mammography was performed in a sample of 2,000 simulation runs. A sensitivity analysis was performed for crucial screening-related parameters. Distinct scenarios for recall and detection rates were compared. Statistically significant savings were found for overall costs, treatment costs and the costs of additional tests in the long term. The overall cost saving was 1,115,857€ (95%CI from 932,147 to 1,299,567) in the 10th year and 2,866,124€ (95%CI from 2,492,610 to 3,239,638) in the 20th year, representing 4.5% and 8.1% of the overall cost associated with screen-film mammography. The sensitivity analysis showed net savings in the long term. Switching to digital mammography in a population-based breast cancer screening program saves long-term budget expense, in addition to providing technical advantages. Our results were consistent across distinct scenarios representing the different results obtained in European breast cancer screening programs.
Mariscotti, Giovanna; Belli, Paolo; Bernardi, Daniela; Brancato, Beniamino; Calabrese, Massimo; Carbonaro, Luca A; Cavallo-Marincola, Beatrice; Caumo, Francesca; Clauser, Paola; Martinchich, Laura; Montemezzi, Stefania; Panizza, Pietro; Pediconi, Federica; Tagliafico, Alberto; Trimboli, Rubina M; Zuiani, Chiara; Sardanelli, Francesco
2016-11-01
Women who underwent chest radiation therapy (CRT) during pediatric/young-adult age (typically, lymphoma survivors) have an increased breast cancer risk, in particular for high doses. The cumulative incidence from 40 to 45 years of age is 13-20 %, similar to that of BRCA mutation carriers for whom contrast-enhanced magnetic resonance imaging (MRI) is recommended. However, in women who underwent CRT, MRI sensitivity is lower (63-80 %) and that of mammography higher (67-70 %) than those observed in women with hereditary predisposition, due to a higher incidence of ductal carcinoma in situ with microcalcifications and low neoangiogenesis. A sensitivity close to 95 % can be obtained only using mammography as an adjunct to MRI. Considering the available evidence, women who underwent CRT before 30 receiving a cumulative dose ≥10 Gy should be invited after 25 (or, at least, 8 years after CRT) to attend the following program: 1. interview about individual risk profile and potential of breast imaging; 2. annual MRI using the same protocol recommended for women with hereditary predisposition; 3. annual bilateral two-view full-field digital mammography or digital breast tomosynthesis (DBT) with synthetic 2D reconstructions. Mammography and MRI can be performed at once or alternately every 6 months. In the case of MRI or contrast material contraindications, ultrasound will be performed instead of MRI. Reporting using BI-RADS is recommended. At the age for entering population screening, the individual risk profile will be discussed with the woman about opting for only mammography/DBT screening or for continuing the intensive protocol.
Frankenberg, D; Kelnhofer, K; Bär, K; Frankenberg-Schwager, M
2002-01-01
The fundamental assumption implicit in the use of the atomic bomb survivor data to derive risk estimates is that the gamma rays of Hiroshima and Nagasaki are considered to have biological efficiencies equal to those of other low-LET radiations up to 10 keV/microm, including mammography X rays. Microdosimetric and radiobiological data contradict this assumption. It is therefore of scientific and public interest to evaluate the efficiency of mammography X rays (25-30 kVp) to induce cancer. In this study, the efficiency of mammography X rays relative to 200 kVp X rays to induce neoplastic cell transformation was evaluated using cells of a human hybrid cell line (CGL1). For both radiations, a linear-quadratic dose-effect relationship was observed for neoplastic transformation of CGL1 cells; there was a strong linear component for the 29 kVp X rays. The RBE(M) of mammography X rays relative to 200 kVp X rays was determined to be about 4 for doses < or = 0.5 Gy. A comparison of the electron fluences for both X rays provides strong evidence that electrons with energies of < or = 15 keV can induce neoplastic transformation of CGL1 cells. Both the data available in the literature and the results of the present study strongly suggest an increase of RBE(M) for carcinogenesis in animals, neoplastic cell transformation, and clastogenic effects with decreasing photon energy or increasing LET to an RBE(M) approximately 8 for mammography X rays relative to 60Co gamma rays.
Calo, William A.; Vernon, Sally W.; Lairson, David R.; Linder, Stephen H.
2015-01-01
Background An emerging literature reports that women who reside in socioeconomically deprived communities are less likely to adhere to mammography screening. This study explored associations between area-level socioeconomic measures and mammography screening among a racially and ethnically diverse sample of women in Texas. Methods We conducted a cross-sectional multilevel study linking individual-level data from the 2010 Health of Houston Survey and contextual data from the U.S. Census. Women ages 40–74 years (N=1,541) were included in the analyses. We examined tract-level poverty, unemployment, education, Hispanic and Black composition, female-headed householder families, and crowding as contextual measures. Using multilevel logistic regression modeling, we compared most disadvantaged tracts (quartiles 2–4) to the most advantaged tract (quartile 1). Results Overall, 64% of the sample was adherent to mammography screening. Screening rates were lower (P<.05) among Hispanics, those foreign born, women aged 40–49 years, and those with low educational attainment, unemployed, and without health insurance coverage. Women living in areas with high levels of poverty (quartile 2 vs. quartile 1: OR=0.50; 95% CI: 0.30–0.85), Hispanic composition (quartile 3 vs. quartile 1: OR=0.54; 95% CI: 0.32–0.90), and crowding (quartile 4 vs. quartile 1: OR=0.53; 95% CI: 0.29–0.96) were less likely to have up-to-date mammography screening, net of individual-level factors. Conclusion Our findings highlight the importance of examining area-level socioeconomic inequalities in mammography screening. The study represents an advance on previous research because we examined multiple area measures, controlled for key individual-level covariates, used data aggregated at the tract level, and accounted for the nested structure of the data. PMID:26809487
Cost effectiveness of mammography screening for Chinese women.
Wong, Irene O L; Kuntz, Karen M; Cowling, Benjamin J; Lam, Cindy L K; Leung, Gabriel M
2007-08-15
Although the cost effectiveness of screening mammography in most western developed populations has been accepted, it may not apply to Chinese women, who have a much lower breast cancer incidence. The authors estimated the cost effectiveness of biennial mammography in Hong Kong Chinese women to inform evidence-based screening policies. For the current study, a state-transition Markov model was developed to simulate mammography screening, breast cancer diagnosis, and treatment in a hypothetical cohort of Chinese women. The benefit of mammography was modeled by assuming a stage shift, in which cancers in screened women were more likely to be diagnosed at an earlier disease stage. The authors compared costs, quality-adjusted life years (QALYs) saved, and life years saved (LYS) for 5 screening strategies. Biennial screening resulted in a gain in life expectancy ranging from 4.3 days to 9.4 days compared with no screening at an incremental cost of from US $1,166 to US $2,425 per woman. The least costly, nondominated screening option was screening from ages 40 years to 69 years, with an incremental cost-effectiveness ratio (ICER) of US $61,600 per QALY saved or US $64,400 per LYS compared with no screening. In probabilistic sensitivity analyses, the probability of the ICER being below a threshold of US $50,000 per QALY (LYS) was 15.3% (14.6%). The current results suggested that mammography for Hong Kong Chinese women currently may not be cost effective based on the arbitrary threshold of US $50,000 per QALY. However, clinicians must remain vigilant and periodically should revisit the question of population screening: Disease rates in China have been increasing because of westernization and socioeconomic development.
Tye, Sherilyn; Phillips, Kathryn A; Liang, Su-Ying; Haas, Jennifer S
2004-01-01
Objectives To develop a framework of factors to characterize health plans, to identify how plan characteristics were measured in a national survey, and to apply our findings to an analysis of the predictors of screening mammography. Data Source The primary data were from the 1996 Medical Expenditure Panel Survey. Study Design Women ages 40+, with private insurance, and no history of breast cancer were included in the study (N=2,909). We used multivariate logistic regression to estimate mammography utilization in the past two years relative to health plan and demographic factors. Health plan measures included whether there is a defined provider network, whether coverage is restricted to a network, use of gatekeepers, level of cost containment, copayment and deductible amounts, coinsurance rate, and breadth of benefit coverage. Principal Findings We found no significant difference in reported mammography utilization using a dichotomous comparison of individuals enrolled in managed care versus indemnity plans. However, women in health plans with a defined provider network were more likely to report having received a mammogram in the past two years than those without networks (adjusted OR=1.21, 95 percent CI=1.07–1.36), and women in gatekeeper plans were more likely to report receiving mammography than those without gatekeepers (adjusted OR=1.18, 95 percent CI=1.03–1.36). Restricted out-of-network coverage, use of cost containment, enrollee cost sharing, and breadth of benefit coverage did not appear to affect mammography use. Conclusions It is important to examine the effect of individual health plan components on the utilization of health care, rather than use the traditional broader categorizations of managed versus nonmanaged care or simple health plan typologies. PMID:14965083
Comas, Mercè; Arrospide, Arantzazu; Mar, Javier; Sala, Maria; Vilaprinyó, Ester; Hernández, Cristina; Cots, Francesc; Martínez, Juan; Castells, Xavier
2014-01-01
Objective To assess the budgetary impact of switching from screen-film mammography to full-field digital mammography in a population-based breast cancer screening program. Methods A discrete-event simulation model was built to reproduce the breast cancer screening process (biennial mammographic screening of women aged 50 to 69 years) combined with the natural history of breast cancer. The simulation started with 100,000 women and, during a 20-year simulation horizon, new women were dynamically entered according to the aging of the Spanish population. Data on screening were obtained from Spanish breast cancer screening programs. Data on the natural history of breast cancer were based on US data adapted to our population. A budget impact analysis comparing digital with screen-film screening mammography was performed in a sample of 2,000 simulation runs. A sensitivity analysis was performed for crucial screening-related parameters. Distinct scenarios for recall and detection rates were compared. Results Statistically significant savings were found for overall costs, treatment costs and the costs of additional tests in the long term. The overall cost saving was 1,115,857€ (95%CI from 932,147 to 1,299,567) in the 10th year and 2,866,124€ (95%CI from 2,492,610 to 3,239,638) in the 20th year, representing 4.5% and 8.1% of the overall cost associated with screen-film mammography. The sensitivity analysis showed net savings in the long term. Conclusions Switching to digital mammography in a population-based breast cancer screening program saves long-term budget expense, in addition to providing technical advantages. Our results were consistent across distinct scenarios representing the different results obtained in European breast cancer screening programs. PMID:24832200
Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M
2014-01-01
To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.
Marshall, Jessie Kimbrough; Mbah, Olive M; Ford, Jean G; Phelan-Emrick, Darcy; Ahmed, Saifuddin; Bone, Lee; Wenzel, Jennifer; Shapiro, Gary R; Howerton, Mollie; Johnson, Lawrence; Brown, Qiana; Ewing, Altovise; Pollack, Craig Evan
2016-01-01
There is growing evidence that patient navigation improves breast cancer screening rates; however, there are limited efficacy studies of its effect among African American older adult women. To evaluate the effect of patient navigation on screening mammography among African American female Medicare beneficiaries in Baltimore, MD. The Cancer Prevention and Treatment Demonstration (CPTD), a multi-site study, was a randomized controlled trial conducted from April 2006 through December 2010. Community-based and clinical setting. The CPTD Screening Trial enrolled 1905 community-dwelling African American female Medicare beneficiaries who were ≥65 years of age and resided in Baltimore, MD. Participants were recruited from health clinics, community centers, health fairs, mailings using Medicare rosters, and phone calls. Participants were randomized to either: printed educational materials on cancer screening (control group) or printed educational materials + patient navigation services designed to help participants overcome barriers to cancer screening (intervention group). Self-reported receipt of mammography screening within 2 years of the end of the study. The median follow-up period for participants in this analysis was 17.8 months. In weighted multivariable logistic regression analyses, women in the intervention group had significantly higher odds of being up to date on mammography screening at the end of the follow-up period compared to women in the control group (odds ratio [OR] 2.26, 95 % confidence interval [CI]1.59-3.22). The effect of the intervention was stronger among women who were not up to date with mammography screening at enrollment (OR 3.63, 95 % CI 2.09-6.38). Patient navigation among urban African American Medicare beneficiaries increased self-reported mammography utilization. The results suggest that patient navigation for mammography screening should focus on women who are not up to date on their screening.
Early detection of breast cancer in Brazil: data from the National Health Survey, 2013
Silva, Gulnar Azevedo e; de Souza-Júnior, Paulo Roberto Borges; Damacena, Giseli Nogueira; Szwarcwald, Célia Landmann
2017-01-01
ABSTRACT OBJECTIVE To analyze whether the actions of early detection of breast cancer, initiated with the medical request for mammography, differ between users of the Brazilian Unified Health System (SUS) and those who have private health insurance. METHODS From the data collected in the National Health Survey, we estimated the proportions of women who had medical request for mammography according to presence or absence of private health insurance. For assessing the factors related to having mammography medical request, we estimated crude and adjusted odds ratios and respective 95%CI by logistic regression. We also analyzed the main reasons reported for not having performed mammography after medical request, as well as the time between examination and result. RESULTS Of the women interviewed, 66.7% had a medical request for mammography (59.4% among SUS users and 83.9% among those with private health insurance). Having private health insurance, higher education level, and being white were positively associated with having the medical request. Only 5.4% (95%CI 4.8–6.0) of women who received medical request failed to perform mammography – 7.6% were SUS users and 1.7% had health insurance. The most reported reasons for not being able to perform the examination were: not thinking it was necessary; having the test scheduled, but not yet performed; and not being able to schedule it. More than 70% of women received the result with less than one month from its execution. CONCLUSIONS The barriers to access a medical request for mammographic screening for breast cancer are higher among women who depend exclusively on SUS. PMID:28591356
Fixed-facility workplace screening mammography.
Reynolds, H E; Larkin, G N; Jackson, V P; Hawes, D R
1997-02-01
Potential barriers to compliance with screening mammography guidelines include the cost and inconvenience involved with undergoing the procedure. Workplace screening with mobile mammography is one possible approach to the convenience barrier. However, fixed-facility workplace screening is a viable alternative for any company with a large workforce in one location. This paper describes our initial experience with one such fixed facility. The facility was a cooperative venture by a large pharmaceutical company and an academic radiology department to provide convenient, no-cost (to the patient) screening mammography to employees, dependents, and retirees more than 40 years old. The pharmaceutical company built the facility within its corporate headquarters and the academic radiology department provided the equipment and personnel. The company was billed a fixed cost per examination. In the first 22 months of operation, 4210 (of 4559 scheduled) screening mammograms were obtained. The mean age of the population was 53 years old. Ninety percent of the screening mammograms were interpreted as negative or benign; 10% required additional workup. Of the screened population, 62 biopsies were recommended and 60 were performed. Of these, 42 were benign and 18 malignant. The cancer detection rate was 4.3 per 1000 (0.43%). At the time of diagnosis, six patients were stage 0, 10 patients were stage I, one patient was stage II, and one patient was stage III. Eleven of the 18 patients had minimal cancers. Of the patients who completed a satisfaction survey, 97% percent expressed a high degree of satisfaction with the screening process and stated they would use the facility in the future. A fixed facility for workplace screening mammography is a viable way to provide nearly barrier-free access to high-quality mammography. Patient acceptance is high.
Travel by public transit to mammography facilities in 6 US urban areas.
Graham, S; Lewis, B; Flanagan, B; Watson, M; Peipins, L
2015-12-01
We examined lack of private vehicle access and 30 minutes or longer public transportation travel time to mammography facilities for women 40 years of age or older in the urban areas of Boston, Philadelphia, San Antonio, San Diego, Denver, and Seattle to identify transit marginalized populations - women for whom these travel characteristics may jointly present a barrier to clinic access. This ecological study used sex and race/ethnicity data from the 2010 US Census and household vehicle availability data from the American Community Survey 2008-2012, all at Census tract level. Using the public transportation option on Google Trip Planner we obtained the travel time from the centroid of each census tract to all local mammography facilities to determine the nearest mammography facility in each urban area. Median travel times by public transportation to the nearest facility for women with no household access to a private vehicle were obtained by ranking travel time by population group across all U.S. census tracts in each urban area and across the entire study area. The overall median travel times for each urban area for women without household access to a private vehicle ranged from a low of 15 minutes in Boston and Philadelphia to 27 minutes in San Diego. The numbers and percentages of transit marginalized women were then calculated for all urban areas by population group. While black women were less likely to have private vehicle access, and both Hispanic and black women were more likely to be transit marginalized, this outcome varied by urban area. White women constituted the largest number of transit marginalized. Our results indicate that mammography facilities are favorably located for the large majority of women, although there are still substantial numbers for whom travel may likely present a barrier to mammography facility access.
Pataky, Reka; Ismail, Zahra; Coldman, Andrew J; Elwood, Mark; Gelmon, Karen; Hedden, Lindsay; Hislop, Greg; Kan, Lisa; McCoy, Bonnie; Olivotto, Ivo A; Peacock, Stuart
2014-12-01
The sensitivity of screening mammography is much lower among women who have dense breast tissue, compared with women who have largely fatty breasts, and they are also at much higher risk of developing the disease. Increasing mammography screening frequency from biennially to annually has been suggested as a policy option to address the elevated risk in this population. The purpose of this study was to assess the cost-effectiveness of annual versus biennial screening mammography among women aged 50-79 with dense breast tissue. A Markov model was constructed based on screening, diagnostic, and treatment pathways for the population-based screening and cancer care programme in British Columbia, Canada. Model probabilities and screening costs were calculated from screening programme data. Costs for breast cancer treatment were calculated from treatment data, and utility values were obtained from the literature. Incremental cost-effectiveness was expressed as cost per quality adjusted life year (QALY), and probabilistic sensitivity analysis was conducted. Compared with biennial screening, annual screening generated an additional 0.0014 QALYs (95% CI: -0.0480-0.0359) at a cost of $819 ($ = Canadian dollars) per patient (95% CI: 506-1185), resulting in an incremental cost effectiveness ratio of $565,912/QALY. Annual screening had a 37.5% probability of being cost-effective at a willingness-to-pay threshold of $100,000/QALY. There is considerable uncertainty about the incremental cost-effectiveness of annual mammography. Further research on the comparative effectiveness of screening strategies for women with high mammographic breast density is warranted, particularly as digital mammography and density measurement become more widespread, before cost-effectiveness can be reevaluated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.