Influence of a Binder Layer on the Response Time of Pressure-Sensitive Coatings
NASA Astrophysics Data System (ADS)
Zharkova, G. M.; Khachaturyan, V. M.; Malov, A. N.; Lopatkina, A. A.
2002-07-01
The present work describes an experimental study of pressure-sensitive luminescent coatings containing phosphors prepared on different substrates. Data are presented concerning measurements of luminescence intensity and luminescence decay kinetics at different pressures and temperatures.
Farris, Samantha G; Zvolensky, Michael J
2016-07-01
Although anxiety sensitivity has been reliably associated with smoking-anxiety comorbidity, there has not been a test of whether this construct moderates the effect of acute anxious arousal on actual smoking behavior. The present study utilized an experimental design to test the moderating role of anxiety sensitivity on laboratory-induced anxious arousal in terms of smoking urges and topography (puff style). Participants were adult daily smokers (n=90; Mage=43.6 SD =9.7); average 15.8 cigarettes per day). A between-subjects design was used; participants were randomly assigned to complete a biological challenge procedure consisting of either a single vital capacity inhalation of 35% carbon dioxide (CO2)-enriched air mixture or compressed room air. Smoking urges and smoking topography (puff behavior) were assessed before and after the challenge. Results revealed a significant interaction between anxiety sensitivity and experimental condition (b=-9.96, p=0.014), such that high anxiety sensitive smokers exposed to 35% CO2-enriched air reported significantly lower levels of smoking urges, relative to low anxiety sensitive smokers; the conditional effect of anxiety sensitivity was not observed for the room air condition. There were no significant interaction effects of experimental manipulation by anxiety sensitivity for any of the smoking topography outcomes. The present results suggest for smokers with higher levels of anxiety sensitivity, the acute experience of anxious arousal is related to decreased subjective smoking urges. These data invite future research to explore the reasons for dampened smoking urges, including cardiorespiratory symptom severity. © The Author(s) 2016.
Ultrasonic signal enhancement by resonator techniques
NASA Technical Reports Server (NTRS)
Heyman, J. S.
1973-01-01
Ultrasonic resonators increase experimental sensitivity to acoustic dispersion and changes in attenuation. Experimental sensitivity enhancement line shapes are presented which were obtained by modulating the acoustic properties of a CdS resonator with a light beam. Small changes in light level are made to produce almost pure absorptive or dispersive changes in the resonator signal. This effect is due to the coupling of the ultrasonic wave to the CdS conductivity which is proportional to incident light intensity. The resonator conductivity is adjusted in this manner to obtain both dispersive and absorptive sensitivity enhancement line shapes. The data presented verify previous thoretical calculations based on a propagating wave model.
Vinnakota, Kalyan C; Beard, Daniel A; Dash, Ranjan K
2009-01-01
Identification of a complex biochemical system model requires appropriate experimental data. Models constructed on the basis of data from the literature often contain parameters that are not identifiable with high sensitivity and therefore require additional experimental data to identify those parameters. Here we report the application of a local sensitivity analysis to design experiments that will improve the identifiability of previously unidentifiable model parameters in a model of mitochondrial oxidative phosphorylation and tricaboxylic acid cycle. Experiments were designed based on measurable biochemical reactants in a dilute suspension of purified cardiac mitochondria with experimentally feasible perturbations to this system. Experimental perturbations and variables yielding the most number of parameters above a 5% sensitivity level are presented and discussed.
Reda, S M; Soliman, K A
2016-02-01
This work presents an experimental and theoretical study of cyanidin natural dye as a sensitizer for ZnO dye-sensitized solar cells. ZnO nanoparticles were prepared using ammonia and oxalic acid as a capping agent. The calculated average size of the synthesized ZnO with different capping agents was found to be 32.1 nm. Electronic properties of cyanidin and delphinidin dye were studied using density functional theory (DFT) and time-dependent DFT with a B3LYP/6-31G(d,p) level. By comparing the theoretical results with the experimental data, the cyanidin dye can be used as a sensitizer in dye-sensitized solar cells. An efficiency of 0.006% under an AM-1.5 illumination at 100 mW/cm(2) was attained. The influence of dye adsorption time on the solar cell performance is discussed.
Low-temperature sensitivity periodically tapered photonic crystal-fiber-based refractometer.
Wang, Pengfei; Bo, Lin; Guan, Chunying; Semenova, Yuliya; Wu, Qiang; Brambilla, Gilberto; Farrell, Gerald
2013-10-01
In this Letter, an all-fiber refractometer with a simple configuration of periodical tapers on a photonic crystal fiber (PCF) is proposed and investigated experimentally. The proposed fiber refractive index (RI) sensor consists of a PCF sandwiched between two standard single-mode fibers, with tapers periodically fabricated along the PCF using a CO(2) laser beam focused by a ZnSe cylindrical lens. The proposed fiber sensor can be used for RI sensing by measuring the wavelength shift of the multimode interference dip over the transmission spectrum. An average sensitivity of 222 nm/RIU has been experimentally achieved over a RI range from 1.33 to 1.38. The proposed refractometer is also significantly less sensitive to temperature, and an experimental demonstration of this reduced sensitivity is presented. The proposed RI sensor benefits from simplicity and low-cost and achieves a competitive sensitivity compared with other existing fiber-optic sensors.
Sensitivity Enhancement of FBG-Based Strain Sensor.
Li, Ruiya; Chen, Yiyang; Tan, Yuegang; Zhou, Zude; Li, Tianliang; Mao, Jian
2018-05-17
A novel fiber Bragg grating (FBG)-based strain sensor with a high-sensitivity is presented in this paper. The proposed FBG-based strain sensor enhances sensitivity by pasting the FBG on a substrate with a lever structure. This typical mechanical configuration mechanically amplifies the strain of the FBG to enhance overall sensitivity. As this mechanical configuration has a high stiffness, the proposed sensor can achieve a high resonant frequency and a wide dynamic working range. The sensing principle is presented, and the corresponding theoretical model is derived and validated. Experimental results demonstrate that the developed FBG-based strain sensor achieves an enhanced strain sensitivity of 6.2 pm/με, which is consistent with the theoretical analysis result. The strain sensitivity of the developed sensor is 5.2 times of the strain sensitivity of a bare fiber Bragg grating strain sensor. The dynamic characteristics of this sensor are investigated through the finite element method (FEM) and experimental tests. The developed sensor exhibits an excellent strain-sensitivity-enhancing property in a wide frequency range. The proposed high-sensitivity FBG-based strain sensor can be used for small-amplitude micro-strain measurement in harsh industrial environments.
Sensitivity Enhancement of FBG-Based Strain Sensor
Chen, Yiyang; Tan, Yuegang; Zhou, Zude; Mao, Jian
2018-01-01
A novel fiber Bragg grating (FBG)-based strain sensor with a high-sensitivity is presented in this paper. The proposed FBG-based strain sensor enhances sensitivity by pasting the FBG on a substrate with a lever structure. This typical mechanical configuration mechanically amplifies the strain of the FBG to enhance overall sensitivity. As this mechanical configuration has a high stiffness, the proposed sensor can achieve a high resonant frequency and a wide dynamic working range. The sensing principle is presented, and the corresponding theoretical model is derived and validated. Experimental results demonstrate that the developed FBG-based strain sensor achieves an enhanced strain sensitivity of 6.2 pm/με, which is consistent with the theoretical analysis result. The strain sensitivity of the developed sensor is 5.2 times of the strain sensitivity of a bare fiber Bragg grating strain sensor. The dynamic characteristics of this sensor are investigated through the finite element method (FEM) and experimental tests. The developed sensor exhibits an excellent strain-sensitivity-enhancing property in a wide frequency range. The proposed high-sensitivity FBG-based strain sensor can be used for small-amplitude micro-strain measurement in harsh industrial environments. PMID:29772826
Vesselinova, Neda; Alexandrov, Boian; Wall, Michael E.
2016-11-08
We present a dynamical model of drug accumulation in bacteria. The model captures key features in experimental time courses on ofloxacin accumulation: initial uptake; two-phase response; and long-term acclimation. In combination with experimental data, the model provides estimates of import and export rates in each phase, the time of entry into the second phase, and the decrease of internal drug during acclimation. Global sensitivity analysis, local sensitivity analysis, and Bayesian sensitivity analysis of the model provide information about the robustness of these estimates, and about the relative importance of different parameters in determining the features of the accumulation time coursesmore » in three different bacterial species: Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The results lead to experimentally testable predictions of the effects of membrane permeability, drug efflux and trapping (e.g., by DNA binding) on drug accumulation. A key prediction is that a sudden increase in ofloxacin accumulation in both E. coli and S. aureus is accompanied by a decrease in membrane permeability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vesselinova, Neda; Alexandrov, Boian; Wall, Michael E.
We present a dynamical model of drug accumulation in bacteria. The model captures key features in experimental time courses on ofloxacin accumulation: initial uptake; two-phase response; and long-term acclimation. In combination with experimental data, the model provides estimates of import and export rates in each phase, the time of entry into the second phase, and the decrease of internal drug during acclimation. Global sensitivity analysis, local sensitivity analysis, and Bayesian sensitivity analysis of the model provide information about the robustness of these estimates, and about the relative importance of different parameters in determining the features of the accumulation time coursesmore » in three different bacterial species: Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The results lead to experimentally testable predictions of the effects of membrane permeability, drug efflux and trapping (e.g., by DNA binding) on drug accumulation. A key prediction is that a sudden increase in ofloxacin accumulation in both E. coli and S. aureus is accompanied by a decrease in membrane permeability.« less
Nuclear-Spin Gyroscope Based on an Atomic Co-Magnetometer
NASA Technical Reports Server (NTRS)
Romalis, Michael; Komack, Tom; Ghost, Rajat
2008-01-01
An experimental nuclear-spin gyroscope is based on an alkali-metal/noblegas co-magnetometer, which automatically cancels the effects of magnetic fields. Whereas the performances of prior nuclear-spin gyroscopes are limited by sensitivity to magnetic fields, this gyroscope is insensitive to magnetic fields and to other external perturbations. In addition, relative to prior nuclear-spin gyroscopes, this one exhibits greater sensitivity to rotation. There is commercial interest in development of small, highly sensitive gyroscopes. The present experimental device could be a prototype for development of nuclear spin gyroscopes suitable for navigation. In comparison with fiber-optic gyroscopes, these gyroscopes would draw less power and would be smaller, lighter, more sensitive, and less costly.
Experimental results for characterization of a tapered plastic optical fiber sensor based on SPR
NASA Astrophysics Data System (ADS)
Cennamo, N.; Galatus, R.; Zeni, L.
2015-05-01
The experimental results obtained with two different Plastic Optical Fiber (POF) geometries, tapered and not-tapered, for a sensor based on Surface Plasmon Resonance (SPR) are presented. SPR is used for determining the refractive index variations at the interface between a gold layer and a dielectric medium (aqueous medium). In this work SPR sensors in POF configurations, useful for bio-sensing applications, have been realized for the optimization of the sensitivity and experimentally tested. The results show as the sensitivity increases with the tapered POF configuration, when the refractive index of aqueous medium increases.
Sensitivity enhancement of fiber loop cavity ring-down pressure sensor.
Jiang, Yajun; Yang, Dexing; Tang, Daqing; Zhao, Jianlin
2009-11-10
We present a theoretical and experimental study on sensitivity enhancement of a fiber-loop cavity ring-down pressure sensor. The cladding of the sensing fiber is etched in hydrofluoric acid solution to enhance its sensitivity. The experimental results demonstrate that the pressure applied on the sensing fiber is linearly proportional to the difference between the reciprocals of the ring-down time with and without pressure, and the relative sensitivity exponentially increases with decreasing the cladding diameter. When the sensing fiber is etched to 41.15 microm, its sensitivity is about 36 times that of nonetched fiber in the range of 0 to 32.5 MPa. The measured relative standard deviation of the ring-down time is about 0.15% and, correspondingly, the least detectable loss is about 0.00069 dB.
A New Kind of Laser Microphone Using High Sensitivity Pulsed Laser Vibrometer
NASA Technical Reports Server (NTRS)
Wang, Chen-Chia; Trivedi, Sudhir; Jin, Feng; Swaminathan, V.; Prasad, Narasimha S.
2008-01-01
We demonstrate experimentally a new kind of laser microphone using a highly sensitive pulsed laser vibrometer. By using the photo-electromotive-force (photo-EMF) sensors, we present data indicating the real-time detection of surface displacements as small as 4 pm.
Styron, J D; Cooper, G W; Ruiz, C L; Hahn, K D; Chandler, G A; Nelson, A J; Torres, J A; McWatters, B R; Carpenter, Ken; Bonura, M A
2014-11-01
A methodology for obtaining empirical curves relating absolute measured scintillation light output to beta energy deposited is presented. Output signals were measured from thin plastic scintillator using NIST traceable beta and gamma sources and MCNP5 was used to model the energy deposition from each source. Combining the experimental and calculated results gives the desired empirical relationships. To validate, the sensitivity of a beryllium/scintillator-layer neutron activation detector was predicted and then exposed to a known neutron fluence from a Deuterium-Deuterium fusion plasma (DD). The predicted and the measured sensitivity were in statistical agreement.
Sensitivity analysis of urban flood flows to hydraulic controls
NASA Astrophysics Data System (ADS)
Chen, Shangzhi; Garambois, Pierre-André; Finaud-Guyot, Pascal; Dellinger, Guilhem; Terfous, Abdelali; Ghenaim, Abdallah
2017-04-01
Flooding represents one of the most significant natural hazards on each continent and particularly in highly populated areas. Improving the accuracy and robustness of prediction systems has become a priority. However, in situ measurements of floods remain difficult while a better understanding of flood flow spatiotemporal dynamics along with dataset for model validations appear essential. The present contribution is based on a unique experimental device at the scale 1/200, able to produce urban flooding with flood flows corresponding to frequent to rare return periods. The influence of 1D Saint Venant and 2D Shallow water model input parameters on simulated flows is assessed using global sensitivity analysis (GSA). The tested parameters are: global and local boundary conditions (water heights and discharge), spatially uniform or distributed friction coefficient and or porosity respectively tested in various ranges centered around their nominal values - calibrated thanks to accurate experimental data and related uncertainties. For various experimental configurations a variance decomposition method (ANOVA) is used to calculate spatially distributed Sobol' sensitivity indices (Si's). The sensitivity of water depth to input parameters on two main streets of the experimental device is presented here. Results show that the closer from the downstream boundary condition on water height, the higher the Sobol' index as predicted by hydraulic theory for subcritical flow, while interestingly the sensitivity to friction decreases. The sensitivity indices of all lateral inflows, representing crossroads in 1D, are also quantified in this study along with their asymptotic trends along flow distance. The relationship between lateral discharge magnitude and resulting sensitivity index of water depth is investigated. Concerning simulations with distributed friction coefficients, crossroad friction is shown to have much higher influence on upstream water depth profile than street friction coefficients. This methodology could be applied to any urban flood configuration in order to better understand flow dynamics and repartition but also guide model calibration in the light of flow controls.
Development of a sensitive setup for laser spectroscopy studies of very exotic calcium isotopes
NASA Astrophysics Data System (ADS)
Garcia Ruiz, R. F.; Gorges, C.; Bissell, M.; Blaum, K.; Gins, W.; Heylen, H.; Koenig, K.; Kaufmann, S.; Kowalska, M.; Krämer, J.; Lievens, P.; Malbrunot-Ettenauer, S.; Neugart, R.; Neyens, G.; Nörtershäuser, W.; Yordanov, D. T.; Yang, X. F.
2017-04-01
An experimental setup for sensitive high-resolution measurements of hyperfine structure spectra of exotic calcium isotopes has been developed and commissioned at the COLLAPS beam line at ISOLDE, CERN. The technique is based on the radioactive detection of decaying isotopes after optical pumping and state selective neutralization (ROC) (Vermeeren et al 1992 Phys. Rev. Lett. 68 1679). The improvements and developments necessary to extend the applicability of the experimental technique to calcium isotopes produced at rates as low as few ions s-1 are discussed. Numerical calculations of laser-ion interaction and ion-beam simulations were explored to obtain the optimum performance of the experimental setup. Among the implemented features are a multi-step optical pumping region for sensitive measurements of isotopes with hyperfine splitting, a high-voltage platform for adequate control of low-energy ion beams and simultaneous β-detection of neutralized and remaining ions. The commissioning of the experimental setup, and the first online results on neutron-rich calcium isotopes are presented.
Optimizing Experimental Design for Comparing Models of Brain Function
Daunizeau, Jean; Preuschoff, Kerstin; Friston, Karl; Stephan, Klaas
2011-01-01
This article presents the first attempt to formalize the optimization of experimental design with the aim of comparing models of brain function based on neuroimaging data. We demonstrate our approach in the context of Dynamic Causal Modelling (DCM), which relates experimental manipulations to observed network dynamics (via hidden neuronal states) and provides an inference framework for selecting among candidate models. Here, we show how to optimize the sensitivity of model selection by choosing among experimental designs according to their respective model selection accuracy. Using Bayesian decision theory, we (i) derive the Laplace-Chernoff risk for model selection, (ii) disclose its relationship with classical design optimality criteria and (iii) assess its sensitivity to basic modelling assumptions. We then evaluate the approach when identifying brain networks using DCM. Monte-Carlo simulations and empirical analyses of fMRI data from a simple bimanual motor task in humans serve to demonstrate the relationship between network identification and the optimal experimental design. For example, we show that deciding whether there is a feedback connection requires shorter epoch durations, relative to asking whether there is experimentally induced change in a connection that is known to be present. Finally, we discuss limitations and potential extensions of this work. PMID:22125485
Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance
NASA Technical Reports Server (NTRS)
Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.
2002-01-01
This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.
Frequency Response of Pressure Sensitive Paints
NASA Technical Reports Server (NTRS)
Winslow, Neal A.; Carroll, Bruce F.; Setzer, Fred M.
1996-01-01
An experimental method for measuring the frequency response of Pressure Sensitive Paints (PSP) is presented. These results lead to the development of a dynamic correction technique for PSP measurements which is of great importance to the advancement of PSP as a measurement technique. The ability to design such a dynamic corrector is most easily formed from the frequency response of the given system. An example of this correction technique is shown. In addition to the experimental data, an analytical model for the frequency response is developed from the one dimensional mass diffusion equation.
Perinatal maternal stress and serotonin signaling: effects on pain sensitivity in offspring.
Knaepen, Liesbeth; Pawluski, Jodi L; Patijn, Jacob; van Kleef, Maarten; Tibboel, Dick; Joosten, Elbert A
2014-07-01
It has been estimated that 20% of pregnant women are facing perinatal stress and depression. Perinatal maternal stress has been shown to increase pain sensitivity in offspring. For the treatment of their depressive symptoms, pregnant women are frequently prescribed selective serotonin reuptake inhibitors (SSRIs). Since the descending pain inhibitory circuit matures perinatally, perinatal SSRI exposure has been shown to affect pain sensitivity in offspring. In the present review, we summarize experimental and clinical evidence for the effect of perinatal maternal stress and SSRI exposure on pain sensitivity in offspring. Both experimental and clinical studies show the effect of perinatal maternal stress on regulation of the hypothalamic-pituitary-adrenal (HPA) system and the serotonin pain inhibitory system. Alterations in these two systems likely underlie long-term alterations in the development of pain sensitivity. This review sheds light on the effect of perinatal maternal stress and treatment with SSRIs on offspring pain sensitivity, in relation to the developing HPA system and 5-HT signaling. © 2013 Wiley Periodicals, Inc.
’Coxiella Burnetii’ Vaccine Development: Lipopolysaccharide Structural Analysis
1991-02-20
Analytical instrumentation and methodology is presented for the determination of endotoxin -related structures at much improved sensitivity and... ENDOTOXIN CHARACTERIZATION BY SFC .......................... 10 III. COXIELLA BURNETII LPS CHARACTERIZATION A. EXPERIMENTAL...period for the determination of endotoxin -related structures at much improved sensitivity and specificity. Reports, and their applications, are listed in
Sensitivity to Social Contingency and Positive Emotion in 2-Month-Olds
ERIC Educational Resources Information Center
Soussignan, Robert; Nadel, Jacqueline; Canet, Pierre; Gerardin, Priscille
2006-01-01
This study was aimed at sorting out conflicting results in the literature concerning 2-month-olds' sensitivity to interpersonal contingency, and investigated the potential role of infants' positive emotion in contingency detection. Infants were randomly assigned to an experimental group (EG) that was presented an uninterrupted live-replay-live…
Differential die-away instrument: Report on comparison of fuel assembly experiments and simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goodsell, Alison Victoria; Henzl, Vladimir; Swinhoe, Martyn Thomas
2015-01-14
Experimental results of the assay of mock-up (fresh) fuel with the differential die-away (DDA) instrument were compared to the Monte Carlo N-Particle eXtended (MCNPX) simulation results. Most principal experimental observables, the die-away time and the in tegral of the DDA signal in several time domains, have been found in good agreement with the MCNPX simulation results. The remaining discrepancies between the simulation and experimental results are likely due to small differences between the actual experimental setup and the simulated geometry, including uncertainty in the DT neutron generator yield. Within this report we also present a sensitivity study of the DDAmore » instrument which is a complex and sensitive system and demonstrate to what degree it can be impacted by geometry, material composition, and electronics performance.« less
Experimental study on the sensitive depth of backwards detected light in turbid media.
Zhang, Yunyao; Huang, Liqing; Zhang, Ning; Tian, Heng; Zhu, Jingping
2018-05-28
In the recent past, optical spectroscopy and imaging methods for biomedical diagnosis and target enhancing have been widely researched. The challenge to improve the performance of these methods is to know the sensitive depth of the backwards detected light well. Former research mainly employed a Monte Carlo method to run simulations to statistically describe the light sensitive depth. An experimental method for investigating the sensitive depth was developed and is presented here. An absorption plate was employed to remove all the light that may have travelled deeper than the plate, leaving only the light which cannot reach the plate. By measuring the received backwards light intensity and the depth between the probe and the plate, the light intensity distribution along the depth dimension can be achieved. The depth with the maximum light intensity was recorded as the sensitive depth. The experimental results showed that the maximum light intensity was nearly the same in a short depth range. It could be deduced that the sensitive depth was a range, rather than a single depth. This sensitive depth range as well as its central depth increased consistently with the increasing source-detection distance. Relationships between sensitive depth and optical properties were also investigated. It also showed that the reduced scattering coefficient affects the central sensitive depth and the range of the sensitive depth more than the absorption coefficient, so they cannot be simply added as reduced distinct coefficients to describe the sensitive depth. This study provides an efficient method for investigation of sensitive depth. It may facilitate the development of spectroscopy and imaging techniques for biomedical diagnosis and underwater imaging.
Matityahu, Shlomi; Emuna, Moran; Yahel, Eyal; Makov, Guy; Greenberg, Yaron
2015-04-01
We present a novel experimental design for high sensitivity measurements of the electrical resistance of samples at high pressures (0-6 GPa) and high temperatures (300-1000 K) in a "Paris-Edinburgh" type large volume press. Uniquely, the electrical measurements are carried out directly on a small sample, thus greatly increasing the sensitivity of the measurement. The sensitivity to even minor changes in electrical resistance can be used to clearly identify phase transitions in material samples. Electrical resistance measurements are relatively simple and rapid to execute and the efficacy of the present experimental design is demonstrated by measuring the electrical resistance of Pb, Sn, and Bi across a wide domain of temperature-pressure phase space and employing it to identify the loci of phase transitions. Based on these results, the phase diagrams of these elements are reconstructed to high accuracy and found to be in excellent agreement with previous studies. In particular, by mapping the locations of several well-studied reference points in the phase diagram of Sn and Bi, it is demonstrated that a standard calibration exists for the temperature and pressure, thus eliminating the need for direct or indirect temperature and pressure measurements. The present technique will allow simple and accurate mapping of phase diagrams under extreme conditions and may be of particular importance in advancing studies of liquid state anomalies.
POSS, SARAH R.; KUHAR, CHRIS; STOINSKI, TARA S.; HOPKINS, WILLIAM D.
2007-01-01
In this study we investigated the communicative abilities of 10 orangutans (Pongo pygmaeus) and seven western lowland gorillas (Gorilla gorilla gorilla), and particularly focused on their sensitivity to the attentional state of a human experimenter when choosing from a repertoire of both auditory and visual communication strategies. In experiment 1 a banana was placed in front of the subject's cage and a human experimenter was either present or absent. The subject's behavior was recorded for 60 sec. Both gorillas and orangutans gestured (t(16)= −3.58, P<.005) and vocalized (t(16) = −2.47, P<.05) more when the experimenter was present. In experiment 2 a human experimenter held a banana in front of the subject's cage and was oriented either toward or away from the subject. Again the subject's behavior was recorded for 60 sec. In this experiment both gorillas and orangutans gestured significantly more frequently (t(16) = 3.40, P<.005) when the experimenter was oriented toward them. In addition, gorillas and orangutans used other forms of visual communication signals, such as lip pout (t(16) = 3.66, P<.005), barter/trade (t(16) = 2.31, P<.05), and body present (t(16) = 2.31, P<.05) significantly more when an experimenter was facing them. The overall results indicate that both gorillas and orangutans are sensitive to the attentional state of a human experimenter and use appropriate communicative signals to gain that individual's attention. These results are also similar to previous findings on communicative behaviors in chimpanzees. PMID:16967515
Poss, Sarah R; Kuhar, Chris; Stoinski, Tara S; Hopkins, William D
2006-10-01
In this study we investigated the communicative abilities of 10 orangutans (Pongo pygmaeus) and seven western lowland gorillas (Gorilla gorilla gorilla), and particularly focused on their sensitivity to the attentional state of a human experimenter when choosing from a repertoire of both auditory and visual communication strategies. In experiment 1 a banana was placed in front of the subject's cage and a human experimenter was either present or absent. The subject's behavior was recorded for 60 sec. Both gorillas and orangutans gestured (t(16)=-3.58, P<.005) and vocalized (t(16)=-2.47, P<.05) more when the experimenter was present. In experiment 2 a human experimenter held a banana in front of the subject's cage and was oriented either toward or away from the subject. Again the subject's behavior was recorded for 60 sec. In this experiment both gorillas and orangutans gestured significantly more frequently (t(16)=3.40, P<.005) when the experimenter was oriented toward them. In addition, gorillas and orangutans used other forms of visual communication signals, such as lip pout (t(16)=3.66, P<.005), barter/trade (t(16)=2.31, P<.05), and body present (t(16)=2.31, P<.05) significantly more when an experimenter was facing them. The overall results indicate that both gorillas and orangutans are sensitive to the attentional state of a human experimenter and use appropriate communicative signals to gain that individual's attention. These results are also similar to previous findings on communicative behaviors in chimpanzees.
[Analysis and experimental verification of sensitivity and SNR of laser warning receiver].
Zhang, Ji-Long; Wang, Ming; Tian, Er-Ming; Li, Xiao; Wang, Zhi-Bin; Zhang, Yue
2009-01-01
In order to countermeasure increasingly serious threat from hostile laser in modern war, it is urgent to do research on laser warning technology and system, and the sensitivity and signal to noise ratio (SNR) are two important performance parameters in laser warning system. In the present paper, based on the signal statistical detection theory, a method for calculation of the sensitivity and SNR in coherent detection laser warning receiver (LWR) has been proposed. Firstly, the probabilities of the laser signal and receiver noise were analyzed. Secondly, based on the threshold detection theory and Neyman-Pearson criteria, the signal current equation was established by introducing detection probability factor and false alarm rate factor, then, the mathematical expressions of sensitivity and SNR were deduced. Finally, by using method, the sensitivity and SNR of the sinusoidal grating laser warning receiver developed by our group were analyzed, and the theoretic calculation and experimental results indicate that the SNR analysis method is feasible, and can be used in performance analysis of LWR.
Yang, Sheng-Sung; Ho, Chia-Lu; Siu, Sammy
2010-12-01
In this paper, we propose an algorithm based on the central limit theorem to compute the sensitivity of the multilayer perceptron (MLP) due to the errors of the inputs and weights. For simplicity and practicality, all inputs and weights studied here are independently identically distributed (i.i.d.). The theoretical results derived from the proposed algorithm show that the sensitivity of the MLP is affected by the number of layers and the number of neurons adopted in each layer. To prove the reliability of the proposed algorithm, some experimental results of the sensitivity are also presented, and they match the theoretical ones. The good agreement between the theoretical results and the experimental results verifies the reliability and feasibility of the proposed algorithm. Furthermore, the proposed algorithm can also be applied to compute precisely the sensitivity of the MLP with any available activation functions and any types of i.i.d. inputs and weights.
Remote air pollution measurement
NASA Technical Reports Server (NTRS)
Byer, R. L.
1975-01-01
This paper presents a discussion and comparison of the Raman method, the resonance and fluorescence backscatter method, long path absorption methods and the differential absorption method for remote air pollution measurement. A comparison of the above remote detection methods shows that the absorption methods offer the most sensitivity at the least required transmitted energy. Topographical absorption provides the advantage of a single ended measurement, and differential absorption offers the additional advantage of a fully depth resolved absorption measurement. Recent experimental results confirming the range and sensitivity of the methods are presented.
NASA Astrophysics Data System (ADS)
Sciammarella, C. A.; Sainov, Ventseslav; Simova, Eli
1990-04-01
Theoretical analysis and experimental results on holographic moire contouring (HMC) of difussely reflecting objects are presented. The sensitivity and application constraints of the method are discussed. A high signal-to-noise ratio and contrast of the fringes is achieved through the use of high quality silver halide holographic plates HP-650. A good agreement between theoretical and experimental results is observed.
High-Performance Piezoresistive MEMS Strain Sensor with Low Thermal Sensitivity
Mohammed, Ahmed A. S.; Moussa, Walied A.; Lou, Edmond
2011-01-01
This paper presents the experimental evaluation of a new piezoresistive MEMS strain sensor. Geometric characteristics of the sensor silicon carrier have been employed to improve the sensor sensitivity. Surface features or trenches have been introduced in the vicinity of the sensing elements. These features create stress concentration regions (SCRs) and as a result, the strain/stress field was altered. The improved sensing sensitivity compensated for the signal loss. The feasibility of this methodology was proved in a previous work using Finite Element Analysis (FEA). This paper provides the experimental part of the previous study. The experiments covered a temperature range from −50 °C to +50 °C. The MEMS sensors are fabricated using five different doping concentrations. FEA is also utilized to investigate the effect of material properties and layer thickness of the bonding adhesive on the sensor response. The experimental findings are compared to the simulation results to guide selection of bonding adhesive and installation procedure. Finally, FEA was used to analyze the effect of rotational/alignment errors. PMID:22319384
NASA Astrophysics Data System (ADS)
Wang, Zixiao; Tan, Zhongwei; Xing, Rui; Liang, Linjun; Qi, Yanhui; Jian, Shuisheng
2016-10-01
A novel reflective liquid level sensor based on single-mode-offset coreless-single-mode (SOCS) fiber structure is proposed and experimentally demonstrated. Theory analyses and experimental results indicate that offset fusion can remarkably enhance the sensitivity of sensor. Ending-reflecting structure makes the sensor compact and easy to deploy. Meanwhile, we propose a laser sensing system, and the SOCS structure is used as sensing head and laser filter simultaneously. Experimental results show that laser spectra with high optical signal-to-noise ratio (-30 dB) and narrow 3-dB bandwidth (<0.15 nm) are achieved. Various liquids with different indices are used for liquid level sensing, besides, the refractive index sensitivity is also investigated. In measurement range, the sensing system presents steady laser output.
Curros-Criado, M Mar; Herrero, Juan F
2007-01-01
Background Gabapentin is a structural analogue of gamma-aminobutyric acid with strong anticonvulsant and analgesic activities. Important discrepancies are observed on the effectiveness and potency of gabapentin in acute nociception and sensitization due to inflammation and neuropathy. There is also some controversy in the literature on whether gabapentin is only active in central areas of the nervous system or is also effective in the periphery. This is probably due to the use of different experimental models, routes of administration and types of sensitization. The aim of the present study was to investigate the influence of the spinal cord sensitization on the antinociceptive activity of gabapentin in the absence and in the presence of monoarthritis and neuropathy, using the same experimental protocol of stimulation and the same technique of evaluation of antinociception. Methods We studied the antinociceptive effects of iv. gabapentin in spinal cord neuronal responses from adult male Wistar rats using the recording of single motor units technique. Gabapentin was studied in the absence and in the presence of sensitization due to arthritis and neuropathy, combining noxious mechanical and repetitive electrical stimulation (wind-up). Results The experiments showed that gabapentin was effective in arthritic (max. effect of 41 ± 15% of control and ID50 of 1,145 ± 14 micromol/kg; 200 mg/kg) and neuropathic rats (max. effect of 20 ± 8% of control and ID50 of 414 ± 27 micromol/kg; 73 mg/kg) but not in normal rats. The phenomenon of wind-up was dose-dependently reduced by gabapentin in neuropathy but not in normal and arthritic rats. Conclusion We conclude that systemic gabapentin is a potent and effective antinociceptive agent in sensitization caused by arthritis and neuropathy but not in the absence of sensitization. The potency of the antinociception was directly related to the intensity of sensitization in the present experimental conditions. The effect is mainly located in central areas in neuropathy since wind-up was significantly reduced, however, an action on inflammation-induced sensitized nociceptors is also likely. PMID:17550605
Analysis of thermal performance of penetrated multi-layer insulation
NASA Technical Reports Server (NTRS)
Foster, Winfred A., Jr.; Jenkins, Rhonald M.; Yoo, Chai H.; Barrett, William E.
1988-01-01
Results of research performed for the purpose of studying the sensitivity of multi-layer insulation blanket performance caused by penetrations through the blanket are presented. The work described in this paper presents the experimental data obtained from thermal vacuum tests of various penetration geometries similar to those present on the Hubble Space Telescope. The data obtained from these tests is presented in terms of electrical power required sensitivity factors referenced to a multi-layer blanket without a penetration. The results of these experiments indicate that a significant increase in electrical power is required to overcome the radiation heat losses in the vicinity of the penetrations.
An Experimental Investigation of Hypergolic Ignition Delay of Hydrogen Peroxide with Fuel Mixtures
NASA Technical Reports Server (NTRS)
Blevins, John A.; Gostowski, Rudy; Chianese, Silvio
2003-01-01
An experimental investigation of hypergolicity and ignition delay of fuel mixtures with hydrogen peroxide is presented. Example results of high speed photography and schleiren from drop tests are shown. Also, a discussion of the sensitivity to experimental parameters such as drop size and subsequent uncertainty considerations of ignition delay results is presented. It is shown that using the described setup on the mixtures presented, the precision uncertainty is on the order of 6% of average ignition delay and 5% of average decomposition delay. This represents sufficient repeatability for first order discrimination of ignition delay for propellant development and screening. Two mixtures, each using commonly available amines and transition metal compounds, are presented as examples that result in ignition delays on the order of 10 milliseconds.
Development of neutron measurement in high gamma field using new nuclear emulsion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawarabayashi, J.; Ishihara, K.; Takagi, K.
2011-07-01
To precisely measure the neutron emissions from a spent fuel assembly of a fast breeder reactor, we formed nuclear emulsions based on a non-sensitized Oscillation Project with Emulsion tracking Apparatus (OPERA) film with AgBr grain sizes of 60, 90, and 160 nm. The efficiency for {sup 252}Cf neutron detection of the new emulsion was calculated to be 0.7 x 10{sup -4}, which corresponded to an energy range from 0.3 to 2 MeV and was consistent with a preliminary estimate based on experimental results. The sensitivity of the new emulsion was also experimentally estimated by irradiating with 565 keV and 14more » MeV neutrons. The emulsion with an AgBr grain size of 60 nm had the lowest sensitivity among the above three emulsions but was still sensitive enough to detect protons. Furthermore, the experimental data suggested that there was a threshold linear energy transfer of 15 keV/{mu}m for the new emulsion, below which no silver clusters developed. Further development of nuclear emulsion with an AgBr grain size of a few tens of nanometers will be the next stage of the present study. (authors)« less
Computer assisted holographic moire contouring
NASA Astrophysics Data System (ADS)
Sciammarella, Cesar A.
2000-01-01
Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.
Long-term sensitivity of soil carbon turnover to warming.
Knorr, W; Prentice, I C; House, J I; Holland, E A
2005-01-20
The sensitivity of soil carbon to warming is a major uncertainty in projections of carbon dioxide concentration and climate. Experimental studies overwhelmingly indicate increased soil organic carbon (SOC) decomposition at higher temperatures, resulting in increased carbon dioxide emissions from soils. However, recent findings have been cited as evidence against increased soil carbon emissions in a warmer world. In soil warming experiments, the initially increased carbon dioxide efflux returns to pre-warming rates within one to three years, and apparent carbon pool turnover times are insensitive to temperature. It has already been suggested that the apparent lack of temperature dependence could be an artefact due to neglecting the extreme heterogeneity of soil carbon, but no explicit model has yet been presented that can reconcile all the above findings. Here we present a simple three-pool model that partitions SOC into components with different intrinsic turnover rates. Using this model, we show that the results of all the soil-warming experiments are compatible with long-term temperature sensitivity of SOC turnover: they can be explained by rapid depletion of labile SOC combined with the negligible response of non-labile SOC on experimental timescales. Furthermore, we present evidence that non-labile SOC is more sensitive to temperature than labile SOC, implying that the long-term positive feedback of soil decomposition in a warming world may be even stronger than predicted by global models.
Artificial-neural-network-based failure detection and isolation
NASA Astrophysics Data System (ADS)
Sadok, Mokhtar; Gharsalli, Imed; Alouani, Ali T.
1998-03-01
This paper presents the design of a systematic failure detection and isolation system that uses the concept of failure sensitive variables (FSV) and artificial neural networks (ANN). The proposed approach was applied to tube leak detection in a utility boiler system. Results of the experimental testing are presented in the paper.
Diaphragm size and sensitivity for fiber optic pressure sensors
NASA Technical Reports Server (NTRS)
He, Gang; Cuomo, Frank W.; Zuckerwar, Allan J.
1991-01-01
A mechanism which leads to a significant increase in sensitivity and linear operating range in reflective type fiber optic pressure transducers with minute active dimensions is studied. A general theoretical formalism is presented which is in good agreement with the experimental data. These results are found useful in the development of small pressure sensors used in turbulent boundary layer studies and other applications.
Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
NASA Astrophysics Data System (ADS)
Campana, R.; Evangelista, Y.; Fuschino, F.; Ahangarianabhari, M.; Macera, D.; Bertuccio, G.; Grassi, M.; Labanti, C.; Marisaldi, M.; Malcovati, P.; Rachevski, A.; Zampa, G.; Zampa, N.; Andreani, L.; Baldazzi, G.; Del Monte, E.; Favre, Y.; Feroci, M.; Muleri, F.; Rashevskaya, I.; Vacchi, A.; Ficorella, F.; Giacomini, G.; Picciotto, A.; Zuffa, M.
2014-08-01
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.
SPR based hybrid electro-optic biosensor for β-lactam antibiotics determination in water
NASA Astrophysics Data System (ADS)
Galatus, Ramona; Feier, Bogdan; Cristea, Cecilia; Cennamo, Nunzio; Zeni, Luigi
2017-09-01
The present work aims to provide a hybrid platform capable of complementary and sensitive detection of β-lactam antibiotics, ampicillin in particular. The use of an aptamer specific to ampicillin assures good selectivity and sensitivity for the detection of ampicillin from different matrice. This new approach is dedicated for a portable, remote sensing platform based on low-cost, small size and low-power consumption solution. The simple experimental hybrid platform integrates the results from the D-shape surface plasmon resonance plastic optical fiber (SPR-POF) and from the electrochemical (bio)sensor, for the analysis of ampicillin, delivering sensitive and reliable results. The SPR-POF already used in many previous applications is embedded in a new experimental setup with fluorescent fibers emitters, for broadband wavelength analysis, low-power consumption and low-heating capabilities of the sensing platform.
Xu, Li; Jiang, Yong; Qiu, Rong
2018-01-01
In present study, co-pyrolysis behavior of rape straw, waste tire and their various blends were investigated. TG-FTIR indicated that co-pyrolysis was characterized by a four-step reaction, and H 2 O, CH, OH, CO 2 and CO groups were the main products evolved during the process. Additionally, using BBD-based experimental results, best-fit multiple regression models with high R 2 -pred values (94.10% for mass loss and 95.37% for reaction heat), which correlated explanatory variables with the responses, were presented. The derived models were analyzed by ANOVA at 95% confidence interval, F-test, lack-of-fit test and residues normal probability plots implied the models described well the experimental data. Finally, the model uncertainties as well as the interactive effect of these parameters were studied, the total-, first- and second-order sensitivity indices of operating factors were proposed using Sobol' variance decomposition. To the authors' knowledge, this is the first time global parameter sensitivity analysis has been performed in (co-)pyrolysis literature. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sensitivity of charge transport measurements to local inhomogeneities
NASA Astrophysics Data System (ADS)
Koon, Daniel; Wang, Fei; Hjorth Petersen, Dirch; Hansen, Ole
2012-02-01
We derive analytic expressions for the sensitivity of resistive and Hall measurements to local variations in a specimen's material properties in the combined linear limit of both small magnetic fields and small perturbations, presenting exact, algebraic expressions both for four-point probe measurements on an infinite plane and for symmetric, circular van der Pauw discs. We then generalize the results to obtain corrections to the sensitivities both for finite magnetic fields and for finite perturbations. Calculated functions match published results and computer simulations, and provide an intuitive, visual explanation for experimental misassignment of carrier type in n-type ZnO and agree with published experimental results for holes in a uniform material. These results simplify calculation and plotting of the sensitivities on an NxN grid from a problem of order N^5 to one of order N^3 in the arbitrary case and of order N^2 in the handful of cases that can be solved exactly, putting a powerful tool for inhomogeneity analysis in the hands of the researcher: calculation of the sensitivities requires little more than the solution of Laplace's equation on the specimen geometry.
NASA Astrophysics Data System (ADS)
Teo, Adrian J. T.; Li, Holden; Tan, Say Hwa; Yoon, Yong-Jin
2017-06-01
Optical MEMS devices provide fast detection, electromagnetic resilience and high sensitivity. Using this technology, an optical gratings based accelerometer design concept was developed for seismic motion detection purposes that provides miniaturization, high manufacturability, low costs and high sensitivity. Detailed in-house fabrication procedures of a double-sided deep reactive ion etching (DRIE) on a silicon-on-insulator (SOI) wafer for a micro opto electro mechanical system (MOEMS) device are presented and discussed. Experimental results obtained show that the conceptual device successfully captured motion similar to a commercial accelerometer with an average sensitivity of 13.6 mV G-1, and a highest recorded sensitivity of 44.1 mV G-1. A noise level of 13.5 mV was detected due to experimental setup limitations. This is the first MOEMS accelerometer developed using double-sided DRIE on SOI wafer for the application of seismic motion detection, and is a breakthrough technology platform to open up options for lower cost MOEMS devices.
Experimental and analytical studies for the NASA carbon fiber risk assessment
NASA Technical Reports Server (NTRS)
1980-01-01
Various experimental and analytical studies performed for the NASA carbon fiber risk assessment program are described with emphasis on carbon fiber characteristics, sensitivity of electrical equipment and components to shorting or arcing by carbon fibers, attenuation effect of carbon fibers on aircraft landing aids, impact of carbon fibers on industrial facilities. A simple method of estimating damage from airborne carbon fibers is presented.
NASA Technical Reports Server (NTRS)
Miller, James G.
1997-01-01
In this Progress Report, we describe our recent developments of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns for a thin woven composite in an immersion setup. In addition, we compare apparent signal loss measurements of the thin woven composite for phase-sensitive and phase-insensitive detection methods. All images of diffraction patterns have been included on the accompanying CD-ROM in the Adobe(Trademark) Portable Document Format (PDF). Due to the extensive amount of data, however, hardcopies of only a small representative selection of the images are included within the printed report. This Progress Report presents experimental results that support successful implementation of single element as well as one and two-dimensional ultrasonic array technologies for the inspection of textile composite structures. In our previous reports, we have addressed issues regarding beam profiles of ultrasonic pressure fields transmitted through a water reference path and transmitted through a thin woven composite sample path. Furthermore, we presented experimental results of the effect of a thin woven composite on the magnitude of an insonifying ultrasonic pressure field. In addition to the study of ultrasonic beam profiles, we consider issues relevant to the application of single-element, one-dimensional, and two-dimensional array technologies towards probing the mechanical properties of advanced engineering composites and structures. We provide comparisons between phase-sensitive and phase-insensitive detection methods for determination of textile composite structure parameters. We also compare phase-sensitive and phase-insensitive - - ---- ----- apparent signal loss measurements in an effort to study the phenomenon of phase cancellation at the face of a finite-aperture single-element receiver. Furthermore, in this Progress Report we extend our work on ultrasonic beam profile issues through investigation of the phase fronts of the pressure field. In Section H of this Progress Report we briefly describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. Section III details the analysis of the experimental data followed by the experimental results in Section IV. Finally, a discussion of the observations and conclusions is found in Section V.
Cui, Jian; Zhao, Xue-Hong; Wang, Yan; Xiao, Ya-Bing; Jiang, Xue-Hui; Dai, Li
2014-01-01
Flow injection-hydride generation-atomic fluorescence spectrometry was a widely used method in the industries of health, environmental, geological and metallurgical fields for the merit of high sensitivity, wide measurement range and fast analytical speed. However, optimization of this method was too difficult as there exist so many parameters affecting the sensitivity and broadening. Generally, the optimal conditions were sought through several experiments. The present paper proposed a mathematical model between the parameters and sensitivity/broadening coefficients using the law of conservation of mass according to the characteristics of hydride chemical reaction and the composition of the system, which was proved to be accurate as comparing the theoretical simulation and experimental results through the test of arsanilic acid standard solution. Finally, this paper has put a relation map between the parameters and sensitivity/broadening coefficients, and summarized that GLS volume, carrier solution flow rate and sample loop volume were the most factors affecting sensitivity and broadening coefficients. Optimizing these three factors with this relation map, the relative sensitivity was advanced by 2.9 times and relative broadening was reduced by 0.76 times. This model can provide a theoretical guidance for the optimization of the experimental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Lei; Cole, Jacqueline M.; Dai, Chencheng
2014-05-28
The optoelectronic properties of four azo dye-sensitized TiO2 interfaces are systematically studied as a function of a changing dye anchoring group: carboxylate, sulfonate, hydroxyl, and pyridyl. The variation in optoelectronic properties of the free dyes and those in dye/TiO 2 nanocomposites are studied both experimentally and computationally, in the context of prospective dye-sensitized solar cell (DSSC) applications. Experimental UV/vis absorption spectroscopy, cyclic voltammetry, and DSSC device performance testing reveal a strong dependence on the nature of the anchor of the optoelectronic properties of these dyes, both in solution and as dye/TiO2 nanocomposites. First-principles calculations on both an isolated dye/TiO2 clustermore » model (using localized basis sets) and each dye modeled onto the surface of a 2D periodic TiO2 nanostructure (using plane wave basis sets) are presented. Detailed examination of these experimental and computational results, in terms of light harvesting, electron conversion and photovoltaic device performance characteristics, indicates that carboxylate is the best anchoring group, and hydroxyl is the worst, whereas sulfonate and pyridyl groups exhibit competing potential. Different sensitization solvents are found to affect critically the extent of dye adsorption achieved in the dye-sensitization of the TiO2 semiconductor, especially where the anchor is a pyridyl group.« less
Frequency behavior of the residual current devices
NASA Astrophysics Data System (ADS)
Erdei, Z.; Horgos, M.; Lung, C.; Pop-Vadean, A.; Muresan, R.
2017-01-01
This paper presents an experimental investigation into the operating characteristic of residual current devices when in presence of a residual current at a frequency of 60Hz. In order to protect persons and equipment effectively the residual current devices are made to be very sensitive to the ground fault current or the touch current. Because of their high sensitivity the residual current circuit breakers are prone to tripping under no-fault conditions.
NASA Astrophysics Data System (ADS)
Machado, M. R.; Adhikari, S.; Dos Santos, J. M. C.; Arruda, J. R. F.
2018-03-01
Structural parameter estimation is affected not only by measurement noise but also by unknown uncertainties which are present in the system. Deterministic structural model updating methods minimise the difference between experimentally measured data and computational prediction. Sensitivity-based methods are very efficient in solving structural model updating problems. Material and geometrical parameters of the structure such as Poisson's ratio, Young's modulus, mass density, modal damping, etc. are usually considered deterministic and homogeneous. In this paper, the distributed and non-homogeneous characteristics of these parameters are considered in the model updating. The parameters are taken as spatially correlated random fields and are expanded in a spectral Karhunen-Loève (KL) decomposition. Using the KL expansion, the spectral dynamic stiffness matrix of the beam is expanded as a series in terms of discretized parameters, which can be estimated using sensitivity-based model updating techniques. Numerical and experimental tests involving a beam with distributed bending rigidity and mass density are used to verify the proposed method. This extension of standard model updating procedures can enhance the dynamic description of structural dynamic models.
Wei, Yongjie; Ge, Baozhen; Wei, Yaolin
2009-03-20
In general, model-independent algorithms are sensitive to noise during laser particle size measurement. An improved conjugate gradient algorithm (ICGA) that can be used to invert particle size distribution (PSD) from diffraction data is presented. By use of the ICGA to invert simulated data with multiplicative or additive noise, we determined that additive noise is the main factor that induces distorted results. Thus the ICGA is amended by introduction of an iteration step-adjusting parameter and is used experimentally on simulated data and some samples. The experimental results show that the sensitivity of the ICGA to noise is reduced and the inverted results are in accord with the real PSD.
Epstein, Leonard H; Jankowiak, Noelle; Nederkoorn, Chantal; Raynor, Hollie A; French, Simone A; Finkelstein, Eric
2012-04-01
One way in which to modify food purchases is to change prices through tax policy, subsidy policy, or both. We reviewed the growing body of experimental research conducted in the laboratory and in the field that investigates the following: the extent to which price changes influence purchases of targeted and nontargeted foods, total energy, or macronutrients purchased; the interaction of price changes with adjunctive interventions; and moderators of sensitivity to price changes. After a brief overview of economic principles and observational research that addresses these issues, we present a targeted review of experimental research. Experimental research suggests that price changes modify purchases of targeted foods, but research on the overall nutritional quality of purchases is mixed because of substitution effects. There is mixed support for combining price changes with adjunctive interventions, and there are no replicated findings on moderators to price sensitivity in experiments. Additional focused research is needed to better inform food policy development with the aim of improving eating behavior and preventing obesity.
Optimization of a fiber optic flexible disk microphone
NASA Astrophysics Data System (ADS)
Zhang, Gang; Yu, Benli; Wang, Hui; Liu, Fei; Peng, Jun; Wu, Xuqiang
2011-11-01
An optimized design of a fiber optic flexible disk microphone is presented and verified experimentally. The phase sensitivity of optical fiber microphone (both the ideal model with a simply supported disk (SSD) and the model with a clamped disk (CLD)) is analyzed by utilizing theory of plates and shells. The results show that the microphones have an optimum length of the sensing arm when inner radius of the fiber coils, radius and Poisson's radio of the flexible disk have been determined. Under a typical condition depicted in this paper, an optimum phase sensitivity for SSD model of 27.72 rad/Pa (-91.14 dB re 1 rad/μPa) and an optimum phase sensitivity for CLD model of 3.18 rad/Pa (-109.95 dB re 1 rad/μPa), can be achieved in theory. Several sample microphones are fabricated and tested. The experimental results are basically consistent with the theoretical analysis.
Hippocampal GABAA Receptor and Pain Sensitivity during Estrous Cycle in the Rat
Taherianfard, Mahnaz; Mosavi, Mahnaz
2011-01-01
Background: Estradiol and progesterone as well as hippocampal GABAA receptors are believed to play a role in the modulation of pain. The aim of present study was to investigate the effect of intrahippocampal injections of GABAA receptor agonist (muscimol) and GABAA receptor antagonist (picrotoxin) on pain sensitivity during estrous cycle. Methods: Pain sensitivity was evaluated in rats by formalin test during all stages of estrous cycle. Animals were divided into five groups including; 1- control (intact animal); 2- sham 1 receiving 0.75 µl artificial cerebrospinal fluids (ACSF); 3- sham 2 receiving 0.75 µl alcoholic ACSF; 4- experimental 1 receiving 250 or 500 µg/rat of muscimol in 0.75 µl vehicle, and 5- experimental 2 receiving 20 or 30 µg/rat picrotoxin in 0.75 µl vehicle. Data were analyzed by Kruskal-Wallis followed by Tucky's test for pairwise comparisons using a P value of ≤0.50 for statistical significance. Results: Muscimol significantly (P<0.05) decreased pain sensitivity in all stages of estrous cycle, and the analgesic effect was higher during proestrus and estrus stages of estrous cycle than that during metestrus and diestrus stages. Picrotoxin significantly (P<0.05) increased pain sensitivity in all stages of estrous cycle, and such a hyperalgesic effect was lower during proestrus and estrus stages of estrous cycle than that during metestrus and diestrus stages. Conclusion: The findings of the present study indicate that the role of hippocampal GABAA receptor in the control of the pain sensitivity can be modulated by variation in gonadal steroids during different stages of the estrous cycle. PMID:23115414
An Incidence Loss Model for Wave Rotors with Axially Aligned Passages
NASA Technical Reports Server (NTRS)
Paxson, Daniel E.
1998-01-01
A simple mathematical model is described to account for the losses incurred when the flow in the duct (port) of a wave rotor is not aligned with the passages. The model, specifically for wave rotors with axially aligned passages, describes a loss mechanism which is sensitive to incident flow angle and Mach number. Implementation of the model in a one-dimensional CFD based wave rotor simulation is presented. Comparisons with limited experimental results are consistent with the model. Sensitivity studies are presented which highlight the significance of the incidence loss relative to other loss mechanisms in the wave rotor.
Analytical and experimental study of control effort associated with model reference adaptive control
NASA Technical Reports Server (NTRS)
Messer, R. S.; Haftka, R. T.; Cudney, H. H.
1992-01-01
Numerical simulation results presently obtained for the performance of model reference adaptive control (MRAC) are experimentally verified, with a view to accounting for differences between the plant and the reference model after the control function has been brought to bear. MRAC is both experimentally and analytically applied to a single-degree-of-freedom system, as well as analytically to a MIMO system having controlled differences between the reference model and the plant. The control effort is noted to be sensitive to differences between the plant and the reference model.
Intersatellite communications optoelectronics research at the Goddard Space Flight Center
NASA Technical Reports Server (NTRS)
Krainak, Michael A.
1992-01-01
A review is presented of current optoelectronics research and development at the NASA Goddard Space Flight Center for high-power, high-bandwidth laser transmitters; high-bandwidth, high-sensitivity optical receivers; pointing, acquisition, and tracking components; and experimental and theoretical system modeling at the NASA Goddard Space Flight Center. Program hardware and space flight opportunities are presented.
A Practical Model of Quartz Crystal Microbalance in Actual Applications.
Huang, Xianhe; Bai, Qingsong; Hu, Jianguo; Hou, Dong
2017-08-03
A practical model of quartz crystal microbalance (QCM) is presented, which considers both the Gaussian distribution characteristic of mass sensitivity and the influence of electrodes on the mass sensitivity. The equivalent mass sensitivity of 5 MHz and 10 MHz AT-cut QCMs with different sized electrodes were calculated according to this practical model. The equivalent mass sensitivity of this practical model is different from the Sauerbrey's mass sensitivity, and the error between them increases sharply as the electrode radius decreases. A series of experiments which plate rigid gold film onto QCMs were carried out and the experimental results proved this practical model is more valid and correct rather than the classical Sauerbrey equation. The practical model based on the equivalent mass sensitivity is convenient and accurate in actual measurements.
Capuano, Alessandro; Greco, Maria Cristina; Navarra, Pierluigi; Tringali, Giuseppe
2014-10-05
The neural mechanism(s) underlying migraine remain poorly defined at present; preclinical and clinical studies show an involvement of CGRP in this disorder. However current evidence pointed out that CGRP does not exert an algogenic action per se, but it is able to mediate migraine pain only if the trigeminal-vascular system is sensitized. The present study was addressed to investigate CGRP-evoked behavior in nitric oxide (NO) sensitized rats, using an experimental model of nitroglycerin induced sensitization of trigeminal system, looking at neuropeptide release from different cerebral areas after the intra-peritoneal (i.p.) administration of NO-donors. CGRP injected into the rat whisker pad did not induce significant changes in face rubbing behavior compared to controls. On the contrary, CGRP injected in animals pre-treated with 10mg/kg nitroglycerin significantly increased the time spent in face rubbing. Nitroglycerin pre-treated animals did not show any rubbing behavior after locally injected saline. Furthermore, the i.p. treatment with nitroglycerin produced an increase of CGRP levels in brainstem and trigeminal ganglia, but not in the hypothalamus and hippocampus. The absolute amounts of CGRP produced in the brainstem were lower compared to those in the trigeminal ganglion; however, after nitroglycerin stimulation the percentage increase was higher in the brainstem. In conclusion, findings presented in this study suggest that CGRP induces a painful behavior in rats only after sensitization of trigeminal system; thus supporting the concept that a genetic as well as acquired predisposition to trigemino- vascular activation represents the neurobiological basis of CGRP nociceptive effects in migraineurs. Copyright © 2014 Elsevier B.V. All rights reserved.
Simulations on the Influence of Myelin Water in Diffusion-Weighted Imaging
Harkins, Kevin D.; Does, Mark D.
2016-01-01
While myelinated axons present an important barrier to water diffusion, many models used to interpret DWI signal neglect other potential influences of myelin. In this work, Monte Carlo simulations were used to test the sensitivity of DWI results to the diffusive properties of water within myelin. Within these simulations, the apparent diffusion coefficient (Dapp) varied slowly over several orders of magnitude of the coefficient of myelin water diffusion (Dm), but exhibited important differences compared to Dapp values simulated that neglect Dm (=0). Compared to Dapp, the apparent diffusion kurtosis (Kapp) was generally more sensitive to Dm. Simulations also tested the sensitivity of Dapp and Kapp to the amount of myelin present. Unique variations in Dapp and Kapp caused by differences in the myelin volume fraction were diminished when myelin water diffusion was included. Also, expected trends in Dapp and Kapp with experimental echo time were reduced or inverted when accounting for myelin water diffusion, and these reduced/inverted trends were seen experimentally in ex vivo rat brain DWI experiments. In general, myelin water has the potential to subtly influence DWI results and bias models of DWI that neglect these components of white matter. PMID:27271991
Microelectromechanical systems for experimental physics and optical telecommunications
NASA Astrophysics Data System (ADS)
Aksyuk, Vladimir Anatolyevich
1999-12-01
Micro-Electro-Mechanical Systems (MEMS) are an emerging technology, which, when applied to the field of physical sensors, offers not only an obvious advantage of being small and cheap, but more importantly, provides some unique experimental opportunities. These are based on the way physical properties scale with decreasing size. This thesis discusses these basic principles and corresponding advantages and limitations of MEMS technology and presents several experiments in which micromachines are used to do physical measurements that could not be done before. Three types of micromechanical magnetometers are demonstrated. When compared to the state of the art traditional techniques they show greater sensitivity, faster response and can be applied over a wider range of experimental conditions. The high-Q micromechanical torsional oscillator magnetometer is used to observe mesoscopic vortex physics, including single flux lines penetrating into a type-II superconductor just above the first critical field. The Faraday balance ``Trampoline'' magnetometer combines high sensitivity, high bandwidth and can be operated in a wide temperature range. It is used in both high pulsed magnetic fields to record deHaas-vanAlphen oscillations and in DC magnetic fields for magnetization measurements at temperatures down to 100mK. The high sensitivity DC torque magnetometer offers yet higher sensitivity and can be used for a variety of magnetization measurements. Several other MEMS devices for physics and telecommunications applications are presented, including a micromachined near field scanning optical microscope, MEMS fiberoptic switches and large-area large-angle scanners. They provide examples of complex functionality that can be achieved with micromechanics by combining sensors with inherently low-power electrostatic actuators. The optically powered optical power limiter demonstrates the possibility of operating MEMS with optical rather than electrical power.
Millimeter- and submillimeter-wave characterization of various fabrics.
Dunayevskiy, Ilya; Bortnik, Bartosz; Geary, Kevin; Lombardo, Russell; Jack, Michael; Fetterman, Harold
2007-08-20
Transmission measurements of 14 fabrics are presented in the millimeter-wave and submillimeter-wave electromagnetic regions from 130 GHz to 1.2 THz. Three independent sources and experimental set-ups were used to obtain accurate results over a wide spectral range. Reflectivity, a useful parameter for imaging applications, was also measured for a subset of samples in the submillimeter-wave regime along with polarization sensitivity of the transmitted beam and transmission through doubled layers. All of the measurements were performed in free space. Details of these experimental set-ups along with their respective challenges are presented.
Impact parameter sensitive study of inner-shell atomic processes in the experimental storage ring
NASA Astrophysics Data System (ADS)
Gumberidze, A.; Kozhuharov, C.; Zhang, R. T.; Trotsenko, S.; Kozhedub, Y. S.; DuBois, R. D.; Beyer, H. F.; Blumenhagen, K.-H.; Brandau, C.; Bräuning-Demian, A.; Chen, W.; Forstner, O.; Gao, B.; Gassner, T.; Grisenti, R. E.; Hagmann, S.; Hillenbrand, P.-M.; Indelicato, P.; Kumar, A.; Lestinsky, M.; Litvinov, Yu. A.; Petridis, N.; Schury, D.; Spillmann, U.; Trageser, C.; Trassinelli, M.; Tu, X.; Stöhlker, Th.
2017-10-01
In this work, we present a pilot experiment in the experimental storage ring (ESR) at GSI devoted to impact parameter sensitive studies of inner shell atomic processes for low-energy (heavy-) ion-atom collisions. The experiment was performed with bare and He-like xenon ions (Xe54+, Xe52+) colliding with neutral xenon gas atoms, resulting in a symmetric collision system. This choice of the projectile charge states was made in order to compare the effect of a filled K-shell with the empty one. The projectile and target X-rays have been measured at different observation angles for all impact parameters as well as for the impact parameter range of ∼35-70 fm.
Modeling motivated misreports to sensitive survey questions.
Böckenholt, Ulf
2014-07-01
Asking sensitive or personal questions in surveys or experimental studies can both lower response rates and increase item non-response and misreports. Although non-response is easily diagnosed, misreports are not. However, misreports cannot be ignored because they give rise to systematic bias. The purpose of this paper is to present a modeling approach that identifies misreports and corrects for them. Misreports are conceptualized as a motivated process under which respondents edit their answers before they report them. For example, systematic bias introduced by overreports of socially desirable behaviors or underreports of less socially desirable ones can be modeled, leading to more-valid inferences. The proposed approach is applied to a large-scale experimental study and shows that respondents who feel powerful tend to overclaim their knowledge.
Analyzing the Discovery Potential for Light Dark Matter.
Izaguirre, Eder; Krnjaic, Gordan; Schuster, Philip; Toro, Natalia
2015-12-18
In this Letter, we determine the present status of sub-GeV thermal dark matter annihilating through standard model mixing, with special emphasis on interactions through the vector portal. Within representative simple models, we carry out a complete and precise calculation of the dark matter abundance and of all available constraints. We also introduce a concise framework for comparing different experimental approaches, and use this comparison to identify important ranges of dark matter mass and couplings to better explore in future experiments. The requirement that dark matter be a thermal relic sets a sharp sensitivity target for terrestrial experiments, and so we highlight complementary experimental approaches that can decisively reach this milestone sensitivity over the entire sub-GeV mass range.
NASA Astrophysics Data System (ADS)
Ferrara, R.; Leonardi, G.; Jourdan, F.
2013-09-01
A numerical model to predict train-induced vibrations is presented. The dynamic computation considers mutual interactions in vehicle/track coupled systems by means of a finite and discrete elements method. The rail defects and the case of out-of-round wheels are considered. The dynamic interaction between the wheel-sets and the rail is accomplished by using the non-linear Hertzian model with hysteresis damping. A sensitivity analysis is done to evaluate the variables affecting more the maintenance costs. The rail-sleeper contact is assumed extended to an area-defined contact zone, rather than a single-point assumption which fits better real case studies. Experimental validations show how prediction fits well experimental data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qin, Kun; Hu, Shuren; Retterer, Scott T.
Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.
Femtosecond Laser Ablated FBG with Composite Microstructure for Hydrogen Sensor Application.
Zou, Meng; Dai, Yutang; Zhou, Xian; Dong, Ke; Yang, Minghong
2016-12-01
A composite microstructure in fiber Bragg grating (FBG) with film deposition for hydrogen detection is presented. Through ablated to FBG cladding by a femtosecond laser, straight-trenches and spiral micro-pits are formed. A Pd-Ag film is sputtered on the surface of the laser processed FBG single mode fiber, and acts as hydrogen sensing transducer. The demonstrated experimental outcomes show that a composite structure produced the highest sensitivity of 26.3 pm/%H, nearly sevenfold more sensitive compared with original standard FBG. It offers great potential in engineering applications for its good structure stability and sensitivity.
NASA Astrophysics Data System (ADS)
KałuŻyński, P.; Maciak, E.; Herzog, T.; Wójcik, M.
2016-09-01
In this paper we propose low cost and easy in development fully working dye-sensitized solar cell module made with use of a different sensitizing dyes (various anthocyanins and P3HT) for increasing the absorption spectrum, transparent conducting substrates (vaccum spattered chromium and gold), nanometer sized TiO2 film, iodide and methyl viologen dichloride based electrolyte, and a counter electrode (vaccum spattered platinum or carbon). Moreover, some of the different technologies and optimization manufacturing processes were elaborated for energy efficiency increase and were presented in this paper.
Closed-Loop Estimation of Retinal Network Sensitivity by Local Empirical Linearization
2018-01-01
Abstract Understanding how sensory systems process information depends crucially on identifying which features of the stimulus drive the response of sensory neurons, and which ones leave their response invariant. This task is made difficult by the many nonlinearities that shape sensory processing. Here, we present a novel perturbative approach to understand information processing by sensory neurons, where we linearize their collective response locally in stimulus space. We added small perturbations to reference stimuli and tested if they triggered visible changes in the responses, adapting their amplitude according to the previous responses with closed-loop experiments. We developed a local linear model that accurately predicts the sensitivity of the neural responses to these perturbations. Applying this approach to the rat retina, we estimated the optimal performance of a neural decoder and showed that the nonlinear sensitivity of the retina is consistent with an efficient encoding of stimulus information. Our approach can be used to characterize experimentally the sensitivity of neural systems to external stimuli locally, quantify experimentally the capacity of neural networks to encode sensory information, and relate their activity to behavior. PMID:29379871
PSP Measurement of Stator Vane Surface Pressures in a High Speed Fan
NASA Technical Reports Server (NTRS)
Lepicovsky, Jan
1998-01-01
This paper presents measurements of static pressures on the stator vane suction side of a high-speed single stage fan using the technique of pressure sensitive paint (PSP). The paper illustrates development in application of the relatively new experimental technique to the complex environment of internal flows in turbomachines. First, there is a short explanation of the physics of the PSP technique and a discussion of calibration methods for pressure sensitive paint in the turbomachinery environment. A description of the image conversion process follows. The recorded image of the stator vane pressure field is skewed due to the limited optical access and must be converted to the meridional plane projection for comparison with analytical predictions. The experimental results for seven operating conditions along an off-design rotational speed line are shown in a concise form, including performance map points, mindspan static tap pressure distributions, and vane suction side pressure fields. Then, a comparison between static tap and pressure sensitive paint data is discussed. Finally, the paper lists shortcomings of the pressure sensitive paint technology and lessons learned in this high-speed fan application.
Slow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity
Qin, Kun; Hu, Shuren; Retterer, Scott T.; ...
2016-02-05
Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.
Electret accelerometers: physics and dynamic characterization.
Hillenbrand, J; Haberzettl, S; Motz, T; Sessler, G M
2011-06-01
Electret microphones are produced in numbers that significantly exceed those for all other microphone types. This is due to the fact that air-borne electret sensors are of simple and low-cost design but have very good acoustical properties. In contrast, most of the discrete structure-borne sound sensors (or accelerometers) are based on the piezoelectric effect. In the present work, capacitive accelerometers utilizing the electret principle were constructed, built, and characterized. These electret accelerometers comprise a metallic seismic mass, covered by an electret film, a ring of a soft cellular polymer supplying the restoring force, and a metallic backplate. These components replace membrane, spacer, and back electrode, respectively, of the electret microphone. An adjustable static pressure to the seismic mass is generated by two metal springs. The dynamic characterization of the accelerometers was carried out by using an electrodynamic shaker and an external charge or voltage amplifier. Sensors with various seismic masses, air gap distances, and electret voltages were investigated. Charge sensitivities from 10 to 40 pC/g, voltage sensitivities from 600 to 2000 mV/g, and resonance frequencies from 3 to 1.5 kHz were measured. A model describing both the charge and the voltage sensitivity is presented. Good agreement of experimental and calculated values is found. The experimental results show that sensitive, lightweight, and inexpensive electret accelerometers can be built. © 2011 Acoustical Society of America
Experimental artifacts influencing polarization sensitive magneto-Raman spectroscopy
NASA Astrophysics Data System (ADS)
Thirunavukkuarasu, K.; Lu, Z.; Su, L.; Yu, Y.; Cao, L.; Ballotin, M. V.; Christianen, P. C. M.; Zhang, Y.; Smirnov, D.
Since the discovery of graphene, there has been an explosion of research on 2D layered materials such as transition metal dichalcogenides (TMDs). Among several experimental techniques utilized for studying these materials, Raman spectroscopy has proven to be a very powerful tool due to it's sensitivity to layer numbers, interlayer coupling etc. Layered MoS2, member of TMD family, is a typical example with promising applications in nano-optoelectronics. A recent magneto-Raman investigations on MoS2 published by J. Ji etal reported an observation of giant magneto-optical effect. In this work, the intensity of Raman modes exhibited dramatic change in intensities and was attributed to field-induced broken symmetry on Raman scattering cross-section. Due to the ambiguous nature of the interpretation presented in this publication, we performed further Raman studies on MoS2 at high magnetic fields to illustrate the experimental factors overlooked by the previous study. It is highly important to consider the magnetic field-induced rotation of the polarization of the light and its effect on the Raman active phonon modes in anisotropic materials. A detailed report of our magneto-Raman experiments and their outcomes will be presented.
Highly sensitive silicon microreactor for catalyst testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henriksen, Toke R.; Hansen, Ole; Department of Physics, Danish National Research Foundation's Center for Individual Nanoparticle Functionality
2009-12-15
A novel microfabricated chemical reactor for highly sensitive measurements of catalytic activity and surface kinetics is presented. The reactor is fabricated in a silicon chip and is intended for gas-phase reactions at pressures ranging from 0.1 to 5.0 bar. A high sensitivity is obtained by directing the entire gas flow through the catalyst bed to a mass spectrometer, thus ensuring that nearly all reaction products are present in the analyzed gas flow. Although the device can be employed for testing a wide range of catalysts, the primary aim of the design is to allow characterization of model catalysts which canmore » only be obtained in small quantities. Such measurements are of significant fundamental interest but are challenging because of the low surface areas involved. The relationship between the reaction zone gas flow and the pressure in the reaction zone is investigated experimentally. A corresponding theoretical model is presented, and the gas flow through an on-chip flow-limiting capillary is predicted to be in the intermediate regime. The experimental data for the gas flow are found to be in good agreement with the theoretical model. At typical experimental conditions, the total gas flow through the reaction zone is around 3x10{sup 14} molecules s{sup -1}, corresponding to a gas residence time in the reaction zone of about 11 s. To demonstrate the operation of the microreactor, CO oxidation on low-area platinum thin film circles is employed as a test reaction. Using temperature ramping, it is found that platinum catalysts with areas as small as 15 {mu}m{sup 2} are conveniently characterized with the device.« less
USAF Space Sensing Cryogenic Considerations
2010-01-01
Background IR emissions and electronic noise that is inherently present in Focal Plane Arrays (FPAs) and surveillance optics bench designs prevents their use... noise that is inherently present in Focal Plane Arrays (FPAs) and surveillance optics bench designs prevents their use unless they are cooled to...experimental or not of sufficient sensitivity for the before mentioned missions [2]. Examples include Quantum Well IR Photodetectors ( QWIP ), nanotubes
ERIC Educational Resources Information Center
Harrison, Justin; McKay, Ryan
2012-01-01
Temporal discounting rates have become a popular dependent variable in social science research. While choice procedures are commonly employed to measure discounting rates, equivalent present value (EPV) procedures may be more sensitive to experimental manipulation. However, their use has been impeded by the absence of test-retest reliability data.…
NASA Astrophysics Data System (ADS)
Piruzyan, L. A.; Mikhailovskiy, Ye. M.; Piruzyan, A. L.
1999-12-01
The directions of laboratory and clinical studies oriented to experimental confirmation of the priority concept of `laser histochemical surgery' are presented. The goal of the studies is reproduction on experimental model of a number of pathologies (in vivo and in vitro) of the `sensitization to laser radiation by staining' effect. Testing of the histochemical stains as sensitizers to laser irradiation of their `address substrates', i.e. vitally stained intracellular structures which participate in the pathologic processes evolution is under planning. The processes include: (a) metabolic disorders in the brain cells, i.e. disseminated sclerosis; (b) generalized metabolic disorders- -mucopolysaccharidosis and collagenosises (periarteritis nodosa, rheumatism, rheumatoid arthritis, sclerodermia); (3) metabolic disorders in individual organs--vessel atherosclerosis, hypercholesterolemia, myocardial infarction, cardiosclerosis, caries and parodontosis. The conditions of the studies are detailed in the recommendations along the positions: (1) disease name; (2) disease characteristics: (a) pathomorphologic, (b) biochemical; (3) stains revealing the disease signs and recommended for testing; (4) `address substrates' of the stains that are targets for laser radiation; (5) lasers recommended for the testing after the cells staining in vivo in the corresponding pathology; (6) experimental models of the pathologies suggested for the testing; (7) criteria of the stain efficiency as target sensitizer to the laser light (criteria of the `laser sensitization by staining' efficiency). Possible perspectives for the experimental clinical medicine are indicated of common histochemical stains and lasers use and of practice introduction of the `laser histochemical surgery' in the case the described concept is confirmed in experiments and clinically.
NASA Astrophysics Data System (ADS)
Hemmat Esfe, Mohammad; Saedodin, Seyfolah; Rejvani, Mousa; Shahram, Jalal
2017-06-01
In the present study, rheological behavior of ZnO/10W40 nano-lubricant is investigated by an experimental approach. Firstly, ZnO nanoparticles of 10-30 nm were dispersed in 10W40 engine oil with solid volume fractions of 0.25-2%, then the viscosity of the composed nano-lubricant was measured in temperature ranges of 5-55 °C and in various shear rates. From analyzing the results, it was revealed that both of the base oil and nano-lubricants are non-Newtonian fluids which exhibit shear thinning behavior. Sensitivity of viscosity to the solid volume fraction enhancement was calculated by a new correlation which was proposed in terms of solid volume fraction and temperature. In order to attain an accurate model by which experimental data are predicted, an artificial neural network (ANN) with a hidden layer and 5 neurons was designed. This model was considerably accurate in predicting experimental data of dynamic viscosity as R-squared and average absolute relative deviation (AARD %) were respectively 0.9999 and 0.0502.
A self-mixing based ring-type fiber-optic acoustic sensor
NASA Astrophysics Data System (ADS)
Wang, Lutang; Wu, Chunxu; Fang, Nian
2014-07-01
A novel, simple fiber-optic acoustic sensor consisting of a self-mixing effect based laser source and a ring-type interferometer is presented. With weak external optical feedbacks, the acoustic wave signals can be detected by measuring the changes of oscillating frequency of the laser diode, induced by the disturbances of sensing fiber, with the ring-type interferometer. The operation principles of the sensor system are explored in-depth and the experimental researches are carried out. The acoustic wave signals produced by various actions, such as by pencil broken, mental pin free falling and PZT are detected for evaluating the sensing performances of the experimental system. The investigation items include the sensitivity as well as frequency responses of the sensor system. An experiment for the detection of corona discharges is carried out, which occur in a high-voltage environment between two parallel copper electrodes, under different humidity levels. The satisfied experimental results are obtained. These experimental results well prove that our proposed sensing system has very high sensitivity and excellent high frequency responses characteristics in the detections of weak, high-frequency acoustic wave signals.
Epstein, Leonard H; Jankowiak, Noelle; Nederkoorn, Chantal; Raynor, Hollie A; French, Simone A; Finkelstein, Eric
2012-01-01
One way in which to modify food purchases is to change prices through tax policy, subsidy policy, or both. We reviewed the growing body of experimental research conducted in the laboratory and in the field that investigates the following: the extent to which price changes influence purchases of targeted and nontargeted foods, total energy, or macronutrients purchased; the interaction of price changes with adjunctive interventions; and moderators of sensitivity to price changes. After a brief overview of economic principles and observational research that addresses these issues, we present a targeted review of experimental research. Experimental research suggests that price changes modify purchases of targeted foods, but research on the overall nutritional quality of purchases is mixed because of substitution effects. There is mixed support for combining price changes with adjunctive interventions, and there are no replicated findings on moderators to price sensitivity in experiments. Additional focused research is needed to better inform food policy development with the aim of improving eating behavior and preventing obesity. PMID:22378726
Universal sensitivity of speckle intensity correlations to wavefront change in light diffusers
Kim, KyungDuk; Yu, Hyeonseung; Lee, KyeoReh; Park, YongKeun
2017-01-01
Here, we present a concept based on the realization that a complex medium can be used as a simple interferometer. Changes in the wavefront of an incident coherent beam can be retrieved by analyzing changes in speckle patterns when the beam passes through a light diffuser. We demonstrate that the spatial intensity correlations of the speckle patterns are independent of the light diffusers, and are solely determined by the phase changes of an incident beam. With numerical simulations using the random matrix theory, and an experimental pressure-driven wavefront-deforming setup using a microfluidic channel, we theoretically and experimentally confirm the universal sensitivity of speckle intensity correlations, which is attributed to the conservation of optical field correlation despite multiple light scattering. This work demonstrates that a light diffuser works as a simple interferometer, and presents opportunities to retrieve phase information of optical fields with a compact scattering layer in various applications in metrology, analytical chemistry, and biomedicine. PMID:28322268
A heuristic method for identifying chaos from frequency content.
Wiebe, R; Virgin, L N
2012-03-01
The sign of the largest Lyapunov exponent is the fundamental indicator of chaos in a dynamical system. However, although the extraction of Lyapunov exponents can be accomplished with (necessarily noisy) the experimental data, this is still a relatively data-intensive and sensitive endeavor. This paper presents an alternative pragmatic approach to identifying chaos using response frequency characteristics and extending the concept of the spectrogram. The method is shown to work well on both experimental and simulated time series.
A Novel Analysis Method for Paired-Sample Microbial Ecology Experiments.
Olesen, Scott W; Vora, Suhani; Techtmann, Stephen M; Fortney, Julian L; Bastidas-Oyanedel, Juan R; Rodríguez, Jorge; Hazen, Terry C; Alm, Eric J
2016-01-01
Many microbial ecology experiments use sequencing data to measure a community's response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samples and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method's validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of "bottle effects".
NASA Astrophysics Data System (ADS)
McIntyre, Gregory; Neureuther, Andrew; Slonaker, Steve; Vellanki, Venu; Reynolds, Patrick
2006-03-01
The initial experimental verification of a polarization monitoring technique is presented. A series of phase shifting mask patterns produce polarization dependent signals in photoresist and are capable of monitoring the Stokes parameters of any arbitrary illumination scheme. Experiments on two test reticles have been conducted. The first reticle consisted of a series of radial phase gratings (RPG) and employed special apertures to select particular illumination angles. Measurement sensitivities of about 0.3 percent of the clear field per percent change in polarization state were observed. The second test reticle employed the more sensitive proximity effect polarization analyzers (PEPA), a more robust experimental setup, and a backside pinhole layer for illumination angle selection and to enable characterization of the full illuminator. Despite an initial complication with the backside pinhole alignment, the results correlate with theory. Theory suggests that, once the pinhole alignment is corrected in the near future, the second reticle should achieve a measurement sensitivity of about 1 percent of the clear field per percent change in polarization state. This corresponds to a measurement of the Stokes parameters after test mask calibration, to within about 0.02 to 0.03. Various potential improvements to the design, fabrication of the mask, and experimental setup are discussed. Additionally, to decrease measurement time, a design modification and double exposure technique is proposed to enable electrical detection of the measurement signal.
Muris, Peter; Mayer, Birgit; Bervoets, Sabine
2010-08-01
The present study investigated anxiety-related emotional reasoning in 9-13-year-old children using an experimental approach. Eighty-one children completed a computerized ambiguous situations test for assessing their perception of threat under two conditions. In the experimental condition, children were attached to an apparatus that allegedly recorded their heart beat, the sound of which was presented to them via headphones. In the control condition, children listened to the sound of an African djembe drum while completing the ambiguous situations test. It was found that children in the experimental condition generally provided higher threat ratings than children in the control condition, and this difference remained significant when controlling for levels of anxiety sensitivity, panic and other anxiety symptoms. These results are in keeping with the idea that children may partially rely on internal physical sensations when evaluating the dangerousness of ambiguous events. (c) 2010 Elsevier Ltd. All rights reserved.
Square wave voltammetry at the dropping mercury electrode: Experimental
Turner, J.A.; Christie, J.H.; Vukovic, M.; Osteryoung, R.A.
1977-01-01
Experimental verification of earlier theoretical work for square wave voltammetry at the dropping mercury electrode is given. Experiments using ferric oxalate and cadmium(II) in HCl confirm excellent agreement with theory. Experimental peak heights and peak widths are found to be within 2% of calculated results. An example of trace analysis using square wave voltammetry at the DME is presented. The technique is shown to have the same order of sensitivity as differential pulse polarography but is much faster to perform. A detection limit for cadmium in 0.1 M HCl for the system used here was 7 ?? 10-8 M.
A new scenario-based approach to damage detection using operational modal parameter estimates
NASA Astrophysics Data System (ADS)
Hansen, J. B.; Brincker, R.; López-Aenlle, M.; Overgaard, C. F.; Kloborg, K.
2017-09-01
In this paper a vibration-based damage localization and quantification method, based on natural frequencies and mode shapes, is presented. The proposed technique is inspired by a damage assessment methodology based solely on the sensitivity of mass-normalized experimental determined mode shapes. The present method differs by being based on modal data extracted by means of Operational Modal Analysis (OMA) combined with a reasonable Finite Element (FE) representation of the test structure and implemented in a scenario-based framework. Besides a review of the basic methodology this paper addresses fundamental theoretical as well as practical considerations which are crucial to the applicability of a given vibration-based damage assessment configuration. Lastly, the technique is demonstrated on an experimental test case using automated OMA. Both the numerical study as well as the experimental test case presented in this paper are restricted to perturbations concerning mass change.
NASA Astrophysics Data System (ADS)
Dörr, Dominik; Joppich, Tobias; Schirmaier, Fabian; Mosthaf, Tobias; Kärger, Luise; Henning, Frank
2016-10-01
Thermoforming of continuously fiber reinforced thermoplastics (CFRTP) is ideally suited to thin walled and complex shaped products. By means of forming simulation, an initial validation of the producibility of a specific geometry, an optimization of the forming process and the prediction of fiber-reorientation due to forming is possible. Nevertheless, applied methods need to be validated. Therefor a method is presented, which enables the calculation of error measures for the mismatch between simulation results and experimental tests, based on measurements with a conventional coordinate measuring device. As a quantitative measure, describing the curvature is provided, the presented method is also suitable for numerical or experimental sensitivity studies on wrinkling behavior. The applied methods for forming simulation, implemented in Abaqus explicit, are presented and applied to a generic geometry. The same geometry is tested experimentally and simulation and test results are compared by the proposed validation method.
The GammeV suite of experimental searches for axion-like particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steffen, Jason H.; /Fermilab; Upadhye, Amol
2009-08-01
We report on the design and results of the GammeV search for axion-like particles and for chameleon particles. We also discuss plans for an improved experiment to search for chameleon particles, one which is sensitive to both cosmological and power-law chameleon models. Plans for an improved axion-like particle search using coupled resonant cavities are also presented. This experiment will be more sensitive to axion-like particles than stellar astrophysical models or current helioscope experiments.
de Beer, Alex G F; Samson, Jean-Sebastièn; Hua, Wei; Huang, Zishuai; Chen, Xiangke; Allen, Heather C; Roke, Sylvie
2011-12-14
We present a direct comparison of phase sensitive sum-frequency generation experiments with phase reconstruction obtained by the maximum entropy method. We show that both methods lead to the same complex spectrum. Furthermore, we discuss the strengths and weaknesses of each of these methods, analyzing possible sources of experimental and analytical errors. A simulation program for maximum entropy phase reconstruction is available at: http://lbp.epfl.ch/. © 2011 American Institute of Physics
Phase-sensitive fiber-based parametric all-optical switch.
Parra-Cetina, Josué; Kumpera, Aleš; Karlsson, Magnus; Andrekson, Peter A
2015-12-28
We experimentally demonstrate, for the first time, an all-optical switch in a phase-sensitive fiber optic parametric amplifier operated in saturation. We study the effect of phase variation of the signal and idler waves on the pump power depletion. By changing the phase of a 0.9 mW signal/idler pair wave by π/2 rad, a pump power extinction ratio of 30.4 dB is achieved. Static and dynamic characterizations are also performed and time domain results presented.
Dorrian, Jillian; Lamond, Nicole; Kozuchowski, Karolina; Dawson, Drew
2008-11-01
Vigilance technologies are used in the Australian rail industry to address the risks associated with driver sleepiness and fatigue. The aim of this study was to investigate whether a new device, designed to detect lowered states of arousal using electrodermal activity (EDA), would be sensitive to experimentally induced sleepiness and fatigue. Fifteen individuals (7 of them female, 9 male; 18-32 years of age) spent 3 consecutive days in the laboratory, which included 1 night of sustained wakefulness (28 h). The participants completed a 10-min psychomotor vigilance task (PVT) and fatigue and sleepiness ratings every 2 h, and a 30-min driving simulator every 4 h. As was expected, simulated driving, PVT, and subjective ratings indicated increasing levels of sleepiness and fatigue during sustained wakefulness. The EDA device output did not coincide with these findings. The results indicated that the EDA indicator was not sensitive to increased sleepiness and fatigue at the levels produced in the present study.
Sensitive Small Area Photometer
ERIC Educational Resources Information Center
Levenson, M. D.
1970-01-01
Describes a simple photometer capable of measuring small light intensities over small areas. The inexpensive, easy-to- construct instrument is intended for use in a student laboratory to measure the light intensities in a diffraction experiment from single or multiple slits. Typical experimental results are presented along with the theoretical…
Approaching the Limit in Atomic Spectrochemical Analysis.
ERIC Educational Resources Information Center
Hieftje, Gary M.
1982-01-01
To assess the ability of current analytical methods to approach the single-atom detection level, theoretical and experimentally determined detection levels are presented for several chemical elements. A comparison of these methods shows that the most sensitive atomic spectrochemical technique currently available is based on emission from…
NASA Astrophysics Data System (ADS)
Papán, Daniel; Valašková, Veronika; Demeterová, Katarína
2016-10-01
The numerical and experimental approach in structural dynamics problems is more and more current nowadays. This approach is applied and solved in many research and developing institutions of the all the world. Vibrations effect caused by passing trains used in manufacturing facilities can affect the quality of the production activity. This effect is possible to be solved by a numerical or an experimental way. Numerical solution is not so financially and time demanding. The main aim of this article is to focus on just experimental measurement of this problem. In this paper, the case study with measurement due to cramped conditions realized in situ is presented. The case study is located close to railway. The vibration effect caused by passing trains on the high-sensitivity machinery contained in this object were observed. The structure was a high-sensitivity machine that was placed in a construction process. For the measurements, the high-sensitivity standard vibrations equipment was used. The assessments of measurements’ results were performed for the technological conditions and Slovak Standard Criteria. Both of these assessments were divided to amplitude and frequency domain. The amplitude criterion is also divided to peak particle velocity and RMS (Root Mean Square). Frequency domain assessment were realised using the frequency response curves obtained from high-sensitivity machinery manufacturer. The frequency limits are established for each axis of triaxle system. The measurement results can be predicted if the vibration have to be reduced. Measurement implemented in the production hall should obtain materials to determine the seismic loading and response of production machinery caused by technical seismicity.
Asymmetric split-ring resonator-based biosensor for detection of label-free stress biomarkers
NASA Astrophysics Data System (ADS)
Lee, Hee-Jo; Lee, Jung-Hyun; Choi, Suji; Jang, Ik-Soon; Choi, Jong-Soon; Jung, Hyo-Il
2013-07-01
In this paper, an asymmetric split-ring resonator, metamaterial element, is presented as a biosensing transducer for detection of highly sensitive and label-free stress biomarkers. In particular, the two biomarkers, cortisol and α-amylase, are used for evaluating the sensitivity of the proposed biosensor. In case of cortisol detection, the competitive reaction between cortisol-bovine serum albumin and free cortisol is employed, while alpha-amylase is directly detected by its antigen-antibody reaction. From the experimental results, we find that the limit of detection and sensitivity of the proposed sensing device are about 1 ng/ml and 1.155 MHz/ng ml-1, respectively.
Infrared photorefractive effect in doped KNbO3 crystals
NASA Astrophysics Data System (ADS)
Medrano, C.; Zgonik, M.; Liakatas, I.; Günter, P.
1996-11-01
The photorefractive sensitivity of potassium niobate crystals doped with Ce, Co, Cu, Fe, Mn, Ni, and Rh and double-doped with Mn and Rh is investigated over an extended spectral range. We present experimental evidence on extrinsic properties important for the photorefractive effect, such as absorption and effective trap density. Photorefractive gratings are investigated with two-wave mixing experiments. Results on exponential gain, response time, and photorefractive sensitivity at near-infrared wavelengths are reported. The best photorefractive sensitivities at 860 and 1064 nm were obtained in crystals doped with Rh, Fe, Mn, and Mn-Rh. This makes them suitable for applications at laser-diode wavelengths; at 1064 nm, however, Rh:KNbO3 shows a better photorefractive sensitivity than the others. .
NASA Astrophysics Data System (ADS)
Cho, Yeongsu; Berkelbach, Timothy C.
2018-01-01
We present an electrostatic theory of band-gap renormalization in atomically thin semiconductors that captures the strong sensitivity to the surrounding dielectric environment. In particular, our theory aims to correct known band gaps, such as that of the three-dimensional bulk crystal. Combining our quasiparticle band gaps with an effective-mass theory of excitons yields environmentally sensitive optical gaps as would be observed in absorption or photoluminescence. For an isolated monolayer of MoS2, the presented theory is in good agreement with ab initio results based on the G W approximation and the Bethe-Salpeter equation. We find that changes in the electronic band gap are almost exactly offset by changes in the exciton binding energy such that the energy of the first optical transition is nearly independent of the electrostatic environment, rationalizing experimental observations.
NASA Astrophysics Data System (ADS)
Hong, Sinpyo; Lee, Inwon; Park, Seong Hyeon; Lee, Cheolmin; Chun, Ho-Hwan; Lim, Hee Chang
2015-09-01
An experimental study of the effect of mooring systems on the dynamics of a SPAR buoy-type floating offshore wind turbine is presented. The effects of the Center of Gravity (COG), mooring line spring constant, and fair-lead location on the turbine's motion in response to regular waves are investigated. Experimental results show that for a typical mooring system of a SPAR buoy-type Floating Offshore Wind Turbine (FOWT), the effect of mooring systems on the dynamics of the turbine can be considered negligible. However, the pitch decreases notably as the COG increases. The COG and spring constant of the mooring line have a negligible effect on the fairlead displacement. Numerical simulation and sensitivity analysis show that the wind turbine motion and its sensitivity to changes in the mooring system and COG are very large near resonant frequencies. The test results can be used to validate numerical simulation tools for FOWTs.
Impact sensitivity test of liquid energetic materials
NASA Astrophysics Data System (ADS)
Tiutiaev, A.; Dolzhikov, A.; Zvereva, I.
2017-10-01
This paper presents new experimental method for sensitivity evaluation at the impact. A large number of researches shown that the probability of explosion initiating of liquid explosives by impact depends on the chemical nature and the various external characteristics. But the sensitivity of liquid explosive in the presence of gas bubbles increases many times as compared with the liquid without gas bubbles. In this case local chemical reaction focus are formed as a result of compression and heating of the gas inside the bubbles. In the liquid as a result of convection, wave motion, shock, etc. gas bubbles are easily generated, it is necessary to develop methods for determining sensitivity of liquid explosives to impact and to research the explosives ignition with bubbles. For the experimental investigation, the well-known impact machine and the so-called appliance 1 were used. Instead of the metal cup in the standard method in this paper polyurethane foam cylindrical container with liquid explosive was used. Polyurethane foam cylindrical container is easily deforms by impact. A large number of tests with different liquid explosives were made. It was found that the test liquid explosive to impact in appliance 1 with polyurethane foam to a large extent reflect the real mechanical sensitivity due to the small loss of impact energy on the deformation of the metal cup, as well as the best differentiation liquid explosive sensitivity due to the higher resolution method.
A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements
NASA Astrophysics Data System (ADS)
Dennison, Christopher R.; Wild, Peter M.; Wilson, David R.; Cripton, Peter A.
2008-08-01
We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm2, respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics.
Direct experimental observation of nonclassicality in ensembles of single-photon emitters
NASA Astrophysics Data System (ADS)
Moreva, E.; Traina, P.; Forneris, J.; Degiovanni, I. P.; Ditalia Tchernij, S.; Picollo, F.; Brida, G.; Olivero, P.; Genovese, M.
2017-11-01
In this work we experimentally demonstrate a recently proposed criterion addressed to detect nonclassical behavior in the fluorescence emission of ensembles of single-photon emitters. In particular, we apply the method to study clusters of nitrogen-vacancy centers in diamond characterized with single-photon-sensitive confocal microscopy. Theoretical considerations on the behavior of the parameter at any arbitrary order in the presence of Poissonian noise are presented and, finally, the opportunity of detecting manifold coincidences is discussed.
Radiation Tolerant, Low Noise Phase Locked Loops in 65 nm CMOS Technology
NASA Astrophysics Data System (ADS)
Prinzie, Jeffrey; Christiansen, Jorgen; Moreira, Paulo; Steyaert, Michiel; Leroux, Paul
2018-04-01
This work presents an introduction to radiation hardened Phase Locked Loops (PLLs) for nuclear and high-energy physics application. An experimental circuit has been fabricated and irradiated with Xrays up to 600 Mrad. Heavy ions with an LET between 3.2 and 69.2 MeV.cm2/mg were used to verify the SEU cross section of the devices. A Two-photon Absorption (TPA) laser facility has been used to provide detailed results on the SEU sensitivity. The presented circuit employs TMR in the digital logic and an asynchronous phase-frequency detector (PFD) is presented. The PLL has a ringand LC-oscillator to be compared experimentally. The circuit has been fabricated in a 65 nm CMOS technology.
Simulations on the influence of myelin water in diffusion-weighted imaging
NASA Astrophysics Data System (ADS)
Harkins, K. D.; Does, M. D.
2016-07-01
While myelinated axons present an important barrier to water diffusion, many models used to interpret DWI signal neglect other potential influences of myelin. In this work, Monte Carlo simulations were used to test the sensitivity of DWI results to the diffusive properties of water within myelin. Within these simulations, the apparent diffusion coefficient (D app) varied slowly over several orders of magnitude of the coefficient of myelin water diffusion (D m), but exhibited important differences compared to D app values simulated that neglect D m (=0). Compared to D app, the apparent diffusion kurtosis (K app) was generally more sensitive to D m. Simulations also tested the sensitivity of D app and K app to the amount of myelin present. Unique variations in D app and K app caused by differences in the myelin volume fraction were diminished when myelin water diffusion was included. Also, expected trends in D app and K app with experimental echo time were reduced or inverted when accounting for myelin water diffusion, and these reduced/inverted trends were seen experimentally in ex vivo rat brain DWI experiments. In general, myelin water has the potential to subtly influence DWI results and bias models of DWI that neglect these components of white matter.
Leavesley, Silas J; Sweat, Brenner; Abbott, Caitlyn; Favreau, Peter; Rich, Thomas C
2018-01-01
Spectral imaging technologies have been used for many years by the remote sensing community. More recently, these approaches have been applied to biomedical problems, where they have shown great promise. However, biomedical spectral imaging has been complicated by the high variance of biological data and the reduced ability to construct test scenarios with fixed ground truths. Hence, it has been difficult to objectively assess and compare biomedical spectral imaging assays and technologies. Here, we present a standardized methodology that allows assessment of the performance of biomedical spectral imaging equipment, assays, and analysis algorithms. This methodology incorporates real experimental data and a theoretical sensitivity analysis, preserving the variability present in biomedical image data. We demonstrate that this approach can be applied in several ways: to compare the effectiveness of spectral analysis algorithms, to compare the response of different imaging platforms, and to assess the level of target signature required to achieve a desired performance. Results indicate that it is possible to compare even very different hardware platforms using this methodology. Future applications could include a range of optimization tasks, such as maximizing detection sensitivity or acquisition speed, providing high utility for investigators ranging from design engineers to biomedical scientists. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Simulations on the influence of myelin water in diffusion-weighted imaging.
Harkins, K D; Does, M D
2016-07-07
While myelinated axons present an important barrier to water diffusion, many models used to interpret DWI signal neglect other potential influences of myelin. In this work, Monte Carlo simulations were used to test the sensitivity of DWI results to the diffusive properties of water within myelin. Within these simulations, the apparent diffusion coefficient (D app) varied slowly over several orders of magnitude of the coefficient of myelin water diffusion (D m), but exhibited important differences compared to D app values simulated that neglect D m (=0). Compared to D app, the apparent diffusion kurtosis (K app) was generally more sensitive to D m. Simulations also tested the sensitivity of D app and K app to the amount of myelin present. Unique variations in D app and K app caused by differences in the myelin volume fraction were diminished when myelin water diffusion was included. Also, expected trends in D app and K app with experimental echo time were reduced or inverted when accounting for myelin water diffusion, and these reduced/inverted trends were seen experimentally in ex vivo rat brain DWI experiments. In general, myelin water has the potential to subtly influence DWI results and bias models of DWI that neglect these components of white matter.
Akula, Sravani; Kamasani, Swapna; Sivan, Sree Kanth; Manga, Vijjulatha; Vudem, Dashavantha Reddy; Kancha, Rama Krishna
2018-05-01
A significant proportion of patients with lung cancer carry mutations in the EGFR kinase domain. The presence of a deletion mutation in exon 19 or L858R point mutation in the EGFR kinase domain has been shown to cause enhanced efficacy of inhibitor treatment in patients with NSCLC. Several less frequent (uncommon) mutations in the EGFR kinase domain with potential implications in treatment response have also been reported. The role of a limited number of uncommon mutations in drug sensitivity was experimentally verified. However, a huge number of these mutations remain uncharacterized for inhibitor sensitivity or resistance. A large-scale computational analysis of clinically reported 298 point mutants of EGFR kinase domain has been performed, and drug sensitivity profiles for each mutant toward seven kinase inhibitors has been determined by molecular docking. In addition, the relative inhibitor binding affinity toward each drug as compared with that of adenosine triphosphate was calculated for each mutant. The inhibitor sensitivity profiles predicted in this study for a set of previously characterized mutants correlated well with the published clinical, experimental, and computational data. Both the single and compound mutations displayed differential inhibitor sensitivity toward first- and next-generation kinase inhibitors. The present study provides predicted drug sensitivity profiles for a large panel of uncommon EGFR mutations toward multiple inhibitors, which may help clinicians in deciding mutant-specific treatment strategies. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
High sensitivity pressure transducer based on the phase characteristics of GMI magnetic sensors
NASA Astrophysics Data System (ADS)
Benavides, L. S.; Costa Silva, E.; Costa Monteiro, E.; Hall Barbosa, C. R.
2018-03-01
This paper presents a new configuration for a GMI pressure transducer based on the reading of the phase characteristics of GMI sensor, intended for biomedical applications. The development process of this new class of magnetic field transducers is discussed, beginning with the definition of the ideal conditioning of the GMI sensor elements (dc level and frequency of the excitation current and sample length) and continuing with computational simulations of the full electronic circuit performed using the experimental data obtained from measured GMI curves, and have shown that the improvement in the sensitivity of GMI magnetometers is larger when phase-based transducers are used instead of magnitude-based transducers. Parameters of interest of the developed prototype are thoroughly analyzed, such as: sensitivity, linearity and frequency response. Also, the spectral noise density of the developed pressure transducer is evaluated and its resolution in the passband is estimated. A low-cost GMI pressure transducer was developed, presenting high resolution, high sensitivity and a frequency bandwidth compatible to the desired biomedical applications.
Method for estimating off-axis pulse tube losses
NASA Astrophysics Data System (ADS)
Fang, T.; Mulcahey, T. I.; Taylor, R. P.; Spoor, P. S.; Conrad, T. J.; Ghiaasiaan, S. M.
2017-12-01
Some Stirling-type pulse tube cryocoolers (PTCs) exhibit sensitivity to gravitational orientation and often exhibit significant cooling performance losses unless situated with the cold end pointing downward. Prior investigations have indicated that some coolers exhibit sensitivity while others do not; however, a reliable method of predicting the level of sensitivity during the design process has not been developed. In this study, we present a relationship that estimates an upper limit to gravitationally induced losses as a function of the dimensionless pulse tube convection number (NPTC) that can be used to ensure that a PTC would remain functional at adverse static tilt conditions. The empirical relationship is based on experimental data as well as experimentally validated 3-D computational fluid dynamics simulations that examine the effects of frequency, mass flow rate, pressure ratio, mass-pressure phase difference, hot and cold end temperatures, and static tilt angle. The validation of the computational model is based on experimental data collected from six commercial pulse tube cryocoolers. The simulation results are obtained from component-level models of the pulse tube and heat exchangers. Parameter ranges covered in component level simulations are 0-180° for tilt angle, 4-8 for length to diameter ratios, 4-80 K cold tip temperatures, -30° to +30° for mass flow to pressure phase angles, and 25-60 Hz operating frequencies. Simulation results and experimental data are aggregated to yield the relationship between inclined PTC performance and pulse tube convection numbers. The results indicate that the pulse tube convection number can be used as an order of magnitude indicator of the orientation sensitivity, but CFD simulations should be used to calculate the change in energy flow more accurately.
Development of a 300,000-pixel ultrahigh-speed high-sensitivity CCD
NASA Astrophysics Data System (ADS)
Ohtake, H.; Hayashida, T.; Kitamura, K.; Arai, T.; Yonai, J.; Tanioka, K.; Maruyama, H.; Etoh, T. Goji; Poggemann, D.; Ruckelshausen, A.; van Kuijk, H.; Bosiers, Jan T.
2006-02-01
We are developing an ultrahigh-speed, high-sensitivity broadcast camera that is capable of capturing clear, smooth slow-motion videos even where lighting is limited, such as at professional baseball games played at night. In earlier work, we developed an ultrahigh-speed broadcast color camera1) using three 80,000-pixel ultrahigh-speed, highsensitivity CCDs2). This camera had about ten times the sensitivity of standard high-speed cameras, and enabled an entirely new style of presentation for sports broadcasts and science programs. Most notably, increasing the pixel count is crucially important for applying ultrahigh-speed, high-sensitivity CCDs to HDTV broadcasting. This paper provides a summary of our experimental development aimed at improving the resolution of CCD even further: a new ultrahigh-speed high-sensitivity CCD that increases the pixel count four-fold to 300,000 pixels.
INITIAL ASSESSMENT OF SURFACE PRESSURE CHARACTERISTICS OF TWO ROTARY WING UAV DESIGNS
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Watkins, A. Neal; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.; Ingram, Joanne L.
2006-01-01
This paper presents results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of fixed system pressure coefficient response to changes in configuration attitude and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect the magnitude of the response. Pressure coefficients were measured using both conventional pressure taps and via pressure sensitive paint. Comparisons between the two methods are presented and demonstrate that the pressure sensitive paint is a promising method; however, further work on the technique is required.
Wideband optical sensing using pulse interferometry.
Rosenthal, Amir; Razansky, Daniel; Ntziachristos, Vasilis
2012-08-13
Advances in fabrication of high-finesse optical resonators hold promise for the development of miniaturized, ultra-sensitive, wide-band optical sensors, based on resonance-shift detection. Many potential applications are foreseen for such sensors, among them highly sensitive detection in ultrasound and optoacoustic imaging. Traditionally, sensor interrogation is performed by tuning a narrow linewidth laser to the resonance wavelength. Despite the ubiquity of this method, its use has been mostly limited to lab conditions due to its vulnerability to environmental factors and the difficulty of multiplexing - a key factor in imaging applications. In this paper, we develop a new optical-resonator interrogation scheme based on wideband pulse interferometry, potentially capable of achieving high stability against environmental conditions without compromising sensitivity. Additionally, the method can enable multiplexing several sensors. The unique properties of the pulse-interferometry interrogation approach are studied theoretically and experimentally. Methods for noise reduction in the proposed scheme are presented and experimentally demonstrated, while the overall performance is validated for broadband optical detection of ultrasonic fields. The achieved sensitivity is equivalent to the theoretical limit of a 6 MHz narrow-line width laser, which is 40 times higher than what can be usually achieved by incoherent interferometry for the same optical resonator.
Lokajíček, T; Kuchařová, A; Petružálek, M; Šachlová, Š; Svitek, T; Přikryl, R
2016-09-01
Semi-continuous ultrasonic sounding of experimental mortar bars used in the accelerated alkali silica reactivity laboratory test (ASTM C1260) is proposed as a supplementary measurement technique providing data that are highly sensitive to minor changes in the microstructure of hardening/deteriorating concrete mixture. A newly designed, patent pending, heating chamber was constructed allowing ultrasonic sounding of mortar bars, stored in accelerating solution without necessity to remove the test specimens from the bath during the measurement. Subsequent automatic data analysis of recorded ultrasonic signals proved their high correlation to the measured length changes (expansion) and their high sensitivity to microstructural changes. The changes of P-wave velocity, and of the energy, amplitude, and frequency of ultrasonic signal, were in the range of 10-80%, compared to 0.51% change of the length. Results presented in this study thus show that ultrasonic sounding seems to be more sensitive to microstructural changes due to ongoing deterioration of concrete microstructure by alkali-silica reaction than the dimensional changes. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Sazonov, D. S.
2017-12-01
A correlation analysis of the model calculations and experimental measurements of wind-speed sensitivity of a rough sea-surface microwave emission at a frequency of 37.5 GHz are presented. The field data used in the research were collected over 3 years in the summer and autumn periods at the oceanographic platform of the Marine Hydrophysical Institute, Russian Academy of Sciences (RAS). A hypothesis about a significant correlation between the model calculations and experimentally measured sea-surface emission ability caused by wind forcing was formulated and tested to reveal this correlation. An evaluation of the discrepancy between the model and experimental data has been performed by an analysis of residuals. Our studies have shown that among the selected models not a single one adequately describes the experimental data.
Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alessandria, F; Ardito, R; Artusa, DR
We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10 -2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of Tmore » $$0v\\atop{1/2}$$(1θ) = 1.6 \\times 10 26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T$$0v\\atop{1/2}$$(1.64θ) = 9.5 \\times 10 25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76Ge and the preferred range of the neutrino mass parameter space from oscillation results.« less
Impact of early life adversity on EMG stress reactivity of the trapezius muscle.
Luijcks, Rosan; Vossen, Catherine J; Roggeveen, Suzanne; van Os, Jim; Hermens, Hermie J; Lousberg, Richel
2016-09-01
Human and animal research indicates that exposure to early life adversity increases stress sensitivity later in life. While behavioral markers of adversity-induced stress sensitivity have been suggested, physiological markers remain to be elucidated. It is known that trapezius muscle activity increases during stressful situations. The present study examined to what degree early life adverse events experienced during early childhood (0-11 years) and adolescence (12-17 years) moderate experimentally induced electromyographic (EMG) stress activity of the trapezius muscles, in an experimental setting. In a general population sample (n = 115), an anticipatory stress effect was generated by presenting a single unpredictable and uncontrollable electrical painful stimulus at t = 3 minutes. Subjects were unaware of the precise moment of stimulus delivery and its intensity level. Linear and nonlinear time courses in EMG activity were modeled using multilevel analysis. The study protocol included 2 experimental sessions (t = 0 and t = 6 months) allowing for examination of reliability.Results show that EMG stress reactivity during the stress paradigm was consistently stronger in people with higher levels of early life adverse events; early childhood adversity had a stronger moderating effect than adolescent adversity. The impact of early life adversity on EMG stress reactivity may represent a reliable facet that can be used in both clinical and nonclinical studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nauman, A F
1979-01-01
The report presents a compilation of available data on the sensitivity of plants to ionizing radiation, and provides basic information on methods of determining such sensitivities, or of estimating radiosensitivities by calcuation of the nuclear factors upon which they depend. The scope of the data presented here is necessarily limited to the most generally useful radiobiological end points and to the most commonly-used types of radiation. Many of the factors which influence radiosensitivity, particularly nuclear factors, will be discussed. Emphasis will be upon whole-plant studies done at Brookhaven National Laboratory by A.H. Sparrow and his associates, since these studies aremore » the source of most of the available radiosensitivity data and of all the sensitivity predictions listed here. Data presented here include summaries of experimentally-determined radiosensitivities at various end points for both herbaceous and woody higher plants, and for a few species of ferns and lower plants. The algae and fungi have not been considered here due to space limitations.« less
NASA Astrophysics Data System (ADS)
Králik, Juraj
2017-07-01
The paper presents the probabilistic and sensitivity analysis of the efficiency of the damping devices cover of nuclear power plant under impact of the container of nuclear fuel of type TK C30 drop. The finite element idealization of nuclear power plant structure is used in space. The steel pipe damper system is proposed for dissipation of the kinetic energy of the container free fall. The experimental results of the shock-damper basic element behavior under impact loads are presented. The Newmark integration method is used for solution of the dynamic equations. The sensitivity and probabilistic analysis of damping devices was realized in the AntHILL and ANSYS software.
One Nucleon Transfer Reactions Around {sup 68}Ni at REX-ISOLDE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patronis, N.; Raabe, R.; Bree, N.
2008-05-12
The newly built position sensitive Si detectors array of nearly 4{pi} angular coverage which is going to be installed at the REX-ISOLDE facility at CERN is briefly presented. This setup will be combined with the Miniball detectors array, constituting a unique tool for the study of one-nucleon transfer reactions. The experimental study of d({sup 66}Ni,p){sup 67}Ni reaction will be proposed, as a starting point for a series of experiments aiming to the study of the single particle character of the levels of the odd mass neutron reach unstable Ni isotopes. In this contribution, the feasibility and sensitivity of the experimentmore » is presented.« less
Experimental Constraints of the Exotic Shearing of Space-Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, Jonathan William
2016-08-01
The Holometer program is a search for rst experimental evidence that space-time has quantum structure. The detector consists of a pair of co-located 40-m power-recycled interferometers whose outputs are read out synchronously at 50 MHz, achieving sensitivity to spatiallycorrelated uctuations in dierential position on time scales shorter than the light-crossing time of the instruments. Unlike gravitational wave interferometers, which time-resolve transient geometrical disturbances in the spatial background, the Holometer is searching for a universal, stationary quantization noise of the background itself. This dissertation presents the nal results of the Holometer Phase I search, an experiment congured for sensitivity to exoticmore » coherent shearing uctuations of space-time. Measurements of high-frequency cross-spectra of the interferometer signals obtain sensitivity to spatially-correlated eects far exceeding any previous measurement, in a broad frequency band extending to 7.6 MHz, twice the inverse light-crossing time of the apparatus. This measurement is the statistical aggregation of 2.1 petabytes of 2-byte dierential position measurements obtained over a month-long exposure time. At 3 signicance, it places an upper limit on the coherence scale of spatial shear two orders of magnitude below the Planck length. The result demonstrates the viability of this novel spatially-correlated interferometric detection technique to reach unprecedented sensitivity to coherent deviations of space-time from classicality, opening the door for direct experimental tests of theories of relational quantum gravity.« less
NASA Astrophysics Data System (ADS)
Mettot, Clément; Sipp, Denis; Bézard, Hervé
2014-04-01
This article presents a quasi-laminar stability approach to identify in high-Reynolds number flows the dominant low-frequencies and to design passive control means to shift these frequencies. The approach is based on a global linear stability analysis of mean-flows, which correspond to the time-average of the unsteady flows. Contrary to the previous work by Meliga et al. ["Sensitivity of 2-D turbulent flow past a D-shaped cylinder using global stability," Phys. Fluids 24, 061701 (2012)], we use the linearized Navier-Stokes equations based solely on the molecular viscosity (leaving aside any turbulence model and any eddy viscosity) to extract the least stable direct and adjoint global modes of the flow. Then, we compute the frequency sensitivity maps of these modes, so as to predict before hand where a small control cylinder optimally shifts the frequency of the flow. In the case of the D-shaped cylinder studied by Parezanović and Cadot [J. Fluid Mech. 693, 115 (2012)], we show that the present approach well captures the frequency of the flow and recovers accurately the frequency control maps obtained experimentally. The results are close to those already obtained by Meliga et al., who used a more complex approach in which turbulence models played a central role. The present approach is simpler and may be applied to a broader range of flows since it is tractable as soon as mean-flows — which can be obtained either numerically from simulations (Direct Numerical Simulation (DNS), Large Eddy Simulation (LES), unsteady Reynolds-Averaged-Navier-Stokes (RANS), steady RANS) or from experimental measurements (Particle Image Velocimetry - PIV) — are available. We also discuss how the influence of the control cylinder on the mean-flow may be more accurately predicted by determining an eddy-viscosity from numerical simulations or experimental measurements. From a technical point of view, we finally show how an existing compressible numerical simulation code may be used in a black-box manner to extract the global modes and sensitivity maps.
NASA Astrophysics Data System (ADS)
Popota, F. D.; Aguiar, P.; España, S.; Lois, C.; Udias, J. M.; Ros, D.; Pavia, J.; Gispert, J. D.
2015-01-01
In this work a comparison between experimental and simulated data using GATE and PeneloPET Monte Carlo simulation packages is presented. All simulated setups, as well as the experimental measurements, followed exactly the guidelines of the NEMA NU 4-2008 standards using the microPET R4 scanner. The comparison was focused on spatial resolution, sensitivity, scatter fraction and counting rates performance. Both GATE and PeneloPET showed reasonable agreement for the spatial resolution when compared to experimental measurements, although they lead to slight underestimations for the points close to the edge. High accuracy was obtained between experiments and simulations of the system’s sensitivity and scatter fraction for an energy window of 350-650 keV, as well as for the counting rate simulations. The latter was the most complicated test to perform since each code demands different specifications for the characterization of the system’s dead time. Although simulated and experimental results were in excellent agreement for both simulation codes, PeneloPET demanded more information about the behavior of the real data acquisition system. To our knowledge, this constitutes the first validation of these Monte Carlo codes for the full NEMA NU 4-2008 standards for small animal PET imaging systems.
Popota, F D; Aguiar, P; España, S; Lois, C; Udias, J M; Ros, D; Pavia, J; Gispert, J D
2015-01-07
In this work a comparison between experimental and simulated data using GATE and PeneloPET Monte Carlo simulation packages is presented. All simulated setups, as well as the experimental measurements, followed exactly the guidelines of the NEMA NU 4-2008 standards using the microPET R4 scanner. The comparison was focused on spatial resolution, sensitivity, scatter fraction and counting rates performance. Both GATE and PeneloPET showed reasonable agreement for the spatial resolution when compared to experimental measurements, although they lead to slight underestimations for the points close to the edge. High accuracy was obtained between experiments and simulations of the system's sensitivity and scatter fraction for an energy window of 350-650 keV, as well as for the counting rate simulations. The latter was the most complicated test to perform since each code demands different specifications for the characterization of the system's dead time. Although simulated and experimental results were in excellent agreement for both simulation codes, PeneloPET demanded more information about the behavior of the real data acquisition system. To our knowledge, this constitutes the first validation of these Monte Carlo codes for the full NEMA NU 4-2008 standards for small animal PET imaging systems.
Commercial turbofan engine exhaust nozzle flow analyses using PAB3D
NASA Technical Reports Server (NTRS)
Abdol-Hamid, Khaled S.; Uenishi, K.; Carlson, John R.; Keith, B. D.
1992-01-01
Recent developments of a three-dimensional (PAB3D) code have paved the way for a computational investigation of complex aircraft aerodynamic components. The PAB3D code was developed for solving the simplified Reynolds Averaged Navier-Stokes equations in a three-dimensional multiblock/multizone structured mesh domain. The present analysis was applied to commercial turbofan exhaust flow systems. Solution sensitivity to grid density is presented. Laminar flow solutions were developed for all grids and two-equation k-epsilon solutions were developed for selected grids. Static pressure distributions, mass flow and thrust quantities were calculated for on-design engine operating conditions. Good agreement between predicted surface static pressures and experimental data was observed at different locations. Mass flow was predicted within 0.2 percent of experimental data. Thrust forces were typically within 0.4 percent of experimental data.
2017-09-01
VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY CONDITIONS by Matthew D. Bouwense...VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY CONDITIONS 5. FUNDING NUMBERS 6. AUTHOR...unlimited. EXPERIMENTAL VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY
Graphene-Based Liquid-Gated Field Effect Transistor for Biosensing: Theory and Experiments
Reiner-Rozman, Ciril; Larisika, Melanie; Nowak, Christoph; Knoll, Wolfgang
2015-01-01
We present an experimental and theoretical characterization for reduced Graphene-Oxide (rGO) based FETs used for biosensing applications. The presented approach shows a complete result analysis and theoretically predictable electrical properties. The formulation was tested for the analysis of the device performance in the liquid gate mode of operation with variation of the ionic strength and pH-values of the electrolytes in contact with the FET. The dependence on the Debye length was confirmed experimentally and theoretically, utilizing the Debye length as a working parameter and thus defining the limits of applicability for the presented rGO-FETs. Furthermore, the FETs were tested for the sensing of biomolecules (bovine serum albumin (BSA) as reference) binding to gate-immobilized anti-BSA antibodies and analyzed using the Langmuir binding theory for the description of the equilibrium surface coverage as a function of the bulk (analyte) concentration. The obtained binding coefficients for BSA are found to be same as in results from literature, hence confirming the applicability of the devices. The FETs used in the experiments were fabricated using wet-chemically synthesized graphene, displaying high electron and hole mobility (μ) and provide the strong sensitivity also for low potential changes (by change of pH, ion concentration, or molecule adsorption). The binding coefficient for BSA-anti-BSA interaction shows a behavior corresponding to the Langmuir adsorption theory with a Limit of Detection (LOD) in the picomolar concentration range. The presented approach shows high reproducibility and sensitivity and a good agreement of the experimental results with the calculated data. PMID:25791463
A novel analysis method for paired-sample microbial ecology experiments
Olesen, Scott W.; Vora, Suhani; Techtmann, Stephen M.; ...
2016-05-06
Many microbial ecology experiments use sequencing data to measure a community s response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samplesmore » and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method s validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Furthermore, our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of bottle effects .« less
A novel analysis method for paired-sample microbial ecology experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olesen, Scott W.; Vora, Suhani; Techtmann, Stephen M.
Many microbial ecology experiments use sequencing data to measure a community s response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samplesmore » and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method s validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Furthermore, our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of bottle effects .« less
NASA Astrophysics Data System (ADS)
Gang, Tingting; Hu, Manli; Qiao, Xueguang; Li, JiaCheng; Shao, Zhihua; Tong, Rongxin; Rong, Qiangzhou
2017-01-01
A fiber-optic interferometer is proposed and demonstrated experimentally for ultrasonic detection. The sensor consists of a compact Michelson interferometer (MI), which is fixed in a tilted-tube end-face (45°). Thin gold films are used for the reflective coatings of two arms and one of the interference arms is etched serving as the sensing arm. The spectral sideband filter technique is used to interrogate the continuous and pulse ultrasonic signals (with frequency of 300 KHz). Furthermore, because of the asymmetrical structure of the sensor, it presents strong direction-dependent ultrasonic sensitivity, such that the sensor can be considered a vector detector. The experimental results show that the sensor is highly sensitive to ultrasonic signals, and thus it can be a candidate for ultrasonic imaging of seismic physical models.
Superconducting Magnetometry for Cardiovascular Studies and AN Application of Adaptive Filtering.
NASA Astrophysics Data System (ADS)
Leifer, Mark Curtis
Sensitive magnetic detectors utilizing Superconducting Quantum Interference Devices (SQUID's) have been developed and used for studying the cardiovascular system. The theory of magnetic detection of cardiac currents is discussed, and new experimental data supporting the validity of the theory is presented. Measurements on both humans and dogs, in both healthy and diseased states, are presented using the new technique, which is termed vector magnetocardiography. In the next section, a new type of superconducting magnetometer with a room temperature pickup is analyzed, and techniques for optimizing its sensitivity to low-frequency sub-microamp currents are presented. Performance of the actual device displays significantly improved sensitivity in this frequency range, and the ability to measure currents in intact, in vivo biological fibers. The final section reviews the theoretical operation of a digital self-optimizing filter, and presents a four-channel software implementation of the system. The application of the adaptive filter to enhancement of geomagnetic signals for earthquake forecasting is discussed, and the adaptive filter is shown to outperform existing techniques in suppressing noise from geomagnetic records.
Ahn, Hyochol; Weaver, Michael; Lyon, Debra E; Kim, Junglyun; Choi, Eunyoung; Staud, Roland; Fillingim, Roger B
2017-02-01
Ethnicity has been associated with clinical and experimental pain responses. Whereas ethnic disparities in pain in other minority groups compared with whites are well described, pain in Asian Americans remains poorly understood. The purpose of this study was to characterize differences in clinical pain intensity and experimental pain sensitivity among older Asian American and non-Hispanic white (NHW) participants with knee osteoarthritis (OA). Data were collected from 50 Asian Americans ages 45 to 85 (28 Korean, 9 Chinese, 7 Japanese, 5 Filipino, and 1 Indian) and compared with 50 age-matched and sex-matched NHW individuals with symptomatic knee OA pain. The Western Ontario and McMaster Universities Osteoarthritis Index and Graded Chronic Pain Scale were used to assess the intensity of clinical knee pain. In addition, quantitative sensory testing was used to measure experimental sensitivity to heat-induced and mechanically induced pain. Asian American participants had significantly higher levels of clinical pain intensity than NHW participants with knee OA. In addition, Asian American participants had significantly higher experimental pain sensitivity than NHW participants with knee OA. These findings add to the growing literature regarding ethnic and racial differences in clinical pain intensity and experimental pain sensitivity. Asian Americans in particular may be at risk for clinical pain and heightened experimental pain sensitivity. Further investigation is needed to identify the mechanisms underlying ethnic group differences in pain between Asian Americans and NHWs, and to ensure that ethnic group disparities in pain are ameliorated.
Perspective: Optical measurement of feature dimensions and shapes by scatterometry
NASA Astrophysics Data System (ADS)
Diebold, Alain C.; Antonelli, Andy; Keller, Nick
2018-05-01
The use of optical scattering to measure feature shape and dimensions, scatterometry, is now routine during semiconductor manufacturing. Scatterometry iteratively improves an optical model structure using simulations that are compared to experimental data from an ellipsometer. These simulations are done using the rigorous coupled wave analysis for solving Maxwell's equations. In this article, we describe the Mueller matrix spectroscopic ellipsometry based scatterometry. Next, the rigorous coupled wave analysis for Maxwell's equations is presented. Following this, several example measurements are described as they apply to specific process steps in the fabrication of gate-all-around (GAA) transistor structures. First, simulations of measurement sensitivity for the inner spacer etch back step of horizontal GAA transistor processing are described. Next, the simulated metrology sensitivity for sacrificial (dummy) amorphous silicon etch back step of vertical GAA transistor processing is discussed. Finally, we present the application of plasmonically active test structures for improving the sensitivity of the measurement of metal linewidths.
Analysis of image formation in optical coherence elastography using a multiphysics approach
Chin, Lixin; Curatolo, Andrea; Kennedy, Brendan F.; Doyle, Barry J.; Munro, Peter R. T.; McLaughlin, Robert A.; Sampson, David D.
2014-01-01
Image formation in optical coherence elastography (OCE) results from a combination of two processes: the mechanical deformation imparted to the sample and the detection of the resulting displacement using optical coherence tomography (OCT). We present a multiphysics model of these processes, validated by simulating strain elastograms acquired using phase-sensitive compression OCE, and demonstrating close correspondence with experimental results. Using the model, we present evidence that the approximation commonly used to infer sample displacement in phase-sensitive OCE is invalidated for smaller deformations than has been previously considered, significantly affecting the measurement precision, as quantified by the displacement sensitivity and the elastogram signal-to-noise ratio. We show how the precision of OCE is affected not only by OCT shot-noise, as is usually considered, but additionally by phase decorrelation due to the sample deformation. This multiphysics model provides a general framework that could be used to compare and contrast different OCE techniques. PMID:25401007
High sensitivity rotation sensing based on tunable asymmetrical double-ring structure
NASA Astrophysics Data System (ADS)
Gu, Hong; Liu, Xiaoqing
2017-05-01
A very high sensitivity rotation sensor comprising a tunable asymmetrical double-ring structure (TADRS) coupled by a 3 × 3 coupler is presented. The phase difference caused by the TADRS between the counter-propagating waves is derived and discussed. At the resonant frequency, the phase shift difference has the maximum value when the light power in one cavity is amplified about 1.85 times while attenuated 79% in another. The maximum sensitivity of the TADRS sensor is two times larger than that of a single-ring structure. An experimental system is designed to verify the theoretical results and introduce the method of demodulation. The rotation sensor based on TADRS can enhance the sensitivity of the detection of the angular velocity by more than three orders of magnitude.
Does catastrophic thinking enhance oesophageal pain sensitivity? An experimental investigation.
Martel, M O; Olesen, A E; Jørgensen, D; Nielsen, L M; Brock, C; Edwards, R R; Drewes, A M
2016-09-01
Gastro-oesophageal reflux disease (GORD) is a major health problem that is frequently accompanied by debilitating oesophageal pain symptoms. The first objective of the study was to examine the association between catastrophizing and oesophageal pain sensitivity. The second objective was to examine whether catastrophizing was associated with the magnitude of acid-induced oesophageal sensitization. Twenty-five healthy volunteers (median age: 24.0 years; range: 22-31) were recruited and were asked to complete the Pain Catastrophizing Scale (PCS). During two subsequent study visits, mechanical, thermal, and electrical pain sensitivity in the oesophagus was assessed before and after inducing oesophageal sensitization using a 30-min intraluminal oesophageal acid perfusion procedure. Analyses were conducted based on data averaged across the two study visits. At baseline, catastrophizing was significantly associated with mechanical (r = -0.42, p < 0.05) and electrical (r = -0.60, p < 0.01) pain thresholds. After acid perfusion, catastrophizing was also significantly associated with mechanical (r = -0.58, p < 0.01) and electrical (r = -0.50, p < 0.05) pain thresholds. Catastrophizing was not significantly associated with thermal pain thresholds. Subsequent analyses revealed that catastrophizing was not significantly associated with the magnitude of acid-induced oesophageal sensitization. Taken together, findings from the present study suggest that catastrophic thinking exerts an influence on oesophageal pain sensitivity, but not necessarily on the magnitude of acid-induced oesophageal sensitization. WHAT DOES THIS STUDY ADD?: Catastrophizing is associated with heightened pain sensitivity in the oesophagus. This was substantiated by assessing responses to noxious stimulation of the oesophagus using an experimental paradigm mimicking features and symptoms experienced by patients with gastro-oesophageal reflux disease (GORD). © 2016 European Pain Federation - EFIC®
Point-contact sensors: New prospects for a nanoscale-sensitive technique
NASA Astrophysics Data System (ADS)
Kamarchuk, G. V.; Pospelov, A. P.; Yeremenko, A. V.; Faulques, E. C.; Yanson, I. K.
2006-11-01
Point contacts have been discovered to present excellent and unprecedented characteristics when used as gas sensors. A novel concept has been tested successfully and opens the way to useful applications. Copper point contacts were investigated in gas media such as NOx, HCl, H2S and human breath. They reveal high sensitivity to these gases: the measured signal increases by 2-3 orders of magnitude upon gas exposure. Sensor parameters are fully restored when gas action ceases. Stable reproducibility of experimental results was observed after several exposure cycles onto the investigated point contacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filin, V.P.; Loboyko, B.G.; Averin, A.N.
1996-05-01
The results of investigations into sensitivity of the HMX-based explosive compound samples to mechanic stimuli are shown in the presented report. As a result of experimental studies it was illustrated, that explosives deformation and destruction processes under mechanical stimuli are accompanied by occurrence of different electric phenomena. The hypothesis on possible influence of electric phenomena occurring under deformation and destruction on the mechanism of formation of zones with high density of energy is discussed in the report. {copyright} {ital 1996 American Institute of Physics.}
NASA Astrophysics Data System (ADS)
Rodzevich, A. P.; Gazenaur, E. G.; Kuzmina, L. V.; Krasheninin, V. I.; Sokolov, P. N.
2016-08-01
The present work is one of the world first attempts to develop effective methods for controlling explosive sensitivity of energy-related materials with the help of weak electric (up to 1 mV/cm) and magnetic (0.001 T) fields. The resulting experimental data can be used for purposeful alternation of explosive materials reactivity, which is of great practical importance. The proposed technology of producing and processing materials in a weak electric field allows forecasting long-term stability of these materials under various energy impacts.
A shorter and more specific oral sensitization-based experimental model of food allergy in mice.
Bailón, Elvira; Cueto-Sola, Margarita; Utrilla, Pilar; Rodríguez-Ruiz, Judith; Garrido-Mesa, Natividad; Zarzuelo, Antonio; Xaus, Jordi; Gálvez, Julio; Comalada, Mònica
2012-07-31
Cow's milk protein allergy (CMPA) is one of the most prevalent human food-borne allergies, particularly in children. Experimental animal models have become critical tools with which to perform research on new therapeutic approaches and on the molecular mechanisms involved. However, oral food allergen sensitization in mice requires several weeks and is usually associated with unspecific immune responses. To overcome these inconveniences, we have developed a new food allergy model that takes only two weeks while retaining the main characters of allergic response to food antigens. The new model is characterized by oral sensitization of weaned Balb/c mice with 5 doses of purified cow's milk protein (CMP) plus cholera toxin (CT) for only two weeks and posterior challenge with an intraperitoneal administration of the allergen at the end of the sensitization period. In parallel, we studied a conventional protocol that lasts for seven weeks, and also the non-specific effects exerted by CT in both protocols. The shorter protocol achieves a similar clinical score as the original food allergy model without macroscopically affecting gut morphology or physiology. Moreover, the shorter protocol caused an increased IL-4 production and a more selective antigen-specific IgG1 response. Finally, the extended CT administration during the sensitization period of the conventional protocol is responsible for the exacerbated immune response observed in that model. Therefore, the new model presented here allows a reduction not only in experimental time but also in the number of animals required per experiment while maintaining the features of conventional allergy models. We propose that the new protocol reported will contribute to advancing allergy research. Copyright © 2012 Elsevier B.V. All rights reserved.
Liu, Jun; Wang, Jian
2015-07-06
We present a simple configuration incorporating a single polarization-sensitive phase-only liquid crystal spatial light modulator (LC-SLM) to facilitate polarization-insensitive spatial light modulation. The polarization-insensitive configuration is formed by a polarization beam splitter (PBS), a polarization-sensitive phase-only LC-SLM, a half-wave plate (HWP), and a mirror in a loop structure. We experimentally demonstrate polarization-insensitive spatial light modulations for incident linearly polarized beams with different polarization states and polarization-multiplexed beams. Polarization-insensitive spatial light modulations generating orbital angular momentum (OAM) beams are demonstrated in the experiment. The designed polarization-insensitive configuration may find promising applications in spatial light modulations accommodating diverse incident polarizations.
First Dark Matter Constraints from SuperCDMS Single-Charge Sensitive Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnese, R.; et al.
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/more » $$\\mathrm{c^2}$$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.« less
Oxidation Mechanisms of Toluene and Benzene
NASA Technical Reports Server (NTRS)
Bittker, David A.
1995-01-01
An expanded and improved version of a previously published benzene oxidation mechanism is presented and shown to model published experimental data fairly successfully. This benzene submodel is coupled to a modified version of a toluene oxidation submodel from the recent literature. This complete mechanism is shown to successfully model published experimental toluene oxidation data for a highly mixed flow reactor and for higher temperature ignition delay times in a shock tube. A comprehensive sensitivity analysis showing the most important reactions is presented for both the benzene and toluene reacting systems. The NASA Lewis toluene mechanism's modeling capability is found to be equivalent to that of the previously published mechanism which contains a somewhat different benzene submodel.
Effects of Historical and Social Variables on Instruction Following
ERIC Educational Resources Information Center
Kroger-Costa, Andreia; Abreu-Rodrigues, Josele
2012-01-01
The present study investigated the effect of the presence of the experimenter on behavioral sensitivity to contingency change. In history training, college students were exposed to differential reinforcement of low rate (DRL) and fixed-ratio (FR) schedules, and in testing, to a fixed-interval (FI) schedule. For the control group, instructions were…
Decision-Making: Are Plants More Rational than Animals?
Schmid, Bernhard
2016-07-25
A new study presents a novel experimental design and allows a test of risk sensitivity in plants. Faced with a choice between constant and variable resource supply, they make a rational decision for the option that maximizes fitness, a fact rarely observed in animals. Copyright © 2016 Elsevier Ltd. All rights reserved.
Qualitative versus Quantitative Results: An Experimental Introduction to Data Interpretation.
ERIC Educational Resources Information Center
Johnson, Eric R.; Alter, Paula
1989-01-01
Described is an experiment in which the student can ascertain the meaning of a negative result from a qualitative test by performing a more sensitive quantitative test on the same sample. Methodology for testing urinary glucose with a spectrophotometer at 630 nm and with commercial assaying glucose strips is presented. (MVL)
Large-area sheet task advanced dendritic web growth development
NASA Technical Reports Server (NTRS)
Duncan, C. S.; Seidensticker, R. G.; Mchugh, J. P.
1983-01-01
Modeling in the development of low stress configurations for wide web growth is presented. Parametric sensitivity to identify design features which can be used for dynamic trimming of the furnace element was studied. Temperature measurements of experimental growth behavior led to modification in the growth system to improve lateral temperature distributions.
Design and characterization of a magnetoelastic sensor for the detection of biological agents
NASA Astrophysics Data System (ADS)
Shen, Wen; Mathison, Leslie C.; Petrenko, Valery A.; Chin, Bryan A.
2010-01-01
This paper presents the design and development of a free-standing, magnetoelastic biosensor. The detection principle is presented and various resonance characteristics of the sensor are discussed. Experimental measurements of the sensor resonance frequencies agree with theoretical predictions. The influence of the external magnetic field on the resonance behaviour of the sensor was studied and the optimum dc magnetic fields for best sensitivity in air and in water solutions for 2000 × 400 × 15 µm (2 mm) sensors and 1000 × 200 × 15 µm (1 mm) size sensors were determined to be 75 Oe and 38 Oe, respectively. Both theoretical prediction and experimental results show that smaller sensors have greater mass sensitivity and can theoretically detect mass as small as one biological spore. The sensor platform was immobilized with JRB7 phages for specific, in vitro detection of B. anthracis spores. Real-time detection of spores suspended in water was demonstrated using a flowing system. The 1 mm and 2 mm sensors were found to have a detection limit of 104 spores ml-1 and 105 spores ml-1, respectively.
Biomimetic micromechanical adaptive flow-sensor arrays
NASA Astrophysics Data System (ADS)
Krijnen, Gijs; Floris, Arjan; Dijkstra, Marcel; Lammerink, Theo; Wiegerink, Remco
2007-05-01
We report current developments in biomimetic flow-sensors based on flow sensitive mechano-sensors of crickets. Crickets have one form of acoustic sensing evolved in the form of mechanoreceptive sensory hairs. These filiform hairs are highly perceptive to low-frequency sound with energy sensitivities close to thermal threshold. In this work we describe hair-sensors fabricated by a combination of sacrificial poly-silicon technology, to form silicon-nitride suspended membranes, and SU8 polymer processing for fabrication of hairs with diameters of about 50 μm and up to 1 mm length. The membranes have thin chromium electrodes on top forming variable capacitors with the substrate that allow for capacitive read-out. Previously these sensors have been shown to exhibit acoustic sensitivity. Like for the crickets, the MEMS hair-sensors are positioned on elongated structures, resembling the cercus of crickets. In this work we present optical measurements on acoustically and electrostatically excited hair-sensors. We present adaptive control of flow-sensitivity and resonance frequency by electrostatic spring stiffness softening. Experimental data and simple analytical models derived from transduction theory are shown to exhibit good correspondence, both confirming theory and the applicability of the presented approach towards adaptation.
Fabrication and Characterization of a Micro Methanol Sensor Using the CMOS-MEMS Technique.
Fong, Chien-Fu; Dai, Ching-Liang; Wu, Chyan-Chyi
2015-10-23
A methanol microsensor integrated with a micro heater manufactured using the complementary metal oxide semiconductor (CMOS)-microelectromechanical system (MEMS) technique was presented. The sensor has a capability of detecting low concentration methanol gas. Structure of the sensor is composed of interdigitated electrodes, a sensitive film and a heater. The heater located under the interdigitated electrodes is utilized to provide a working temperature to the sensitive film. The sensitive film prepared by the sol-gel method is tin dioxide doped cadmium sulfide, which is deposited on the interdigitated electrodes. To obtain the suspended structure and deposit the sensitive film, the sensor needs a post-CMOS process to etch the sacrificial silicon dioxide layer and silicon substrate. The methanol senor is a resistive type. A readout circuit converts the resistance variation of the sensor into the output voltage. The experimental results show that the methanol sensor has a sensitivity of 0.18 V/ppm.
Fabrication and Characterization of a Micro Methanol Sensor Using the CMOS-MEMS Technique
Fong, Chien-Fu; Dai, Ching-Liang; Wu, Chyan-Chyi
2015-01-01
A methanol microsensor integrated with a micro heater manufactured using the complementary metal oxide semiconductor (CMOS)-microelectromechanical system (MEMS) technique was presented. The sensor has a capability of detecting low concentration methanol gas. Structure of the sensor is composed of interdigitated electrodes, a sensitive film and a heater. The heater located under the interdigitated electrodes is utilized to provide a working temperature to the sensitive film. The sensitive film prepared by the sol-gel method is tin dioxide doped cadmium sulfide, which is deposited on the interdigitated electrodes. To obtain the suspended structure and deposit the sensitive film, the sensor needs a post-CMOS process to etch the sacrificial silicon dioxide layer and silicon substrate. The methanol senor is a resistive type. A readout circuit converts the resistance variation of the sensor into the output voltage. The experimental results show that the methanol sensor has a sensitivity of 0.18 V/ppm. PMID:26512671
NASA Astrophysics Data System (ADS)
García-Moreno, Angel-Iván; González-Barbosa, José-Joel; Ramírez-Pedraza, Alfonso; Hurtado-Ramos, Juan B.; Ornelas-Rodriguez, Francisco-Javier
2016-04-01
Computer-based reconstruction models can be used to approximate urban environments. These models are usually based on several mathematical approximations and the usage of different sensors, which implies dependency on many variables. The sensitivity analysis presented in this paper is used to weigh the relative importance of each uncertainty contributor into the calibration of a panoramic camera-LiDAR system. Both sensors are used for three-dimensional urban reconstruction. Simulated and experimental tests were conducted. For the simulated tests we analyze and compare the calibration parameters using the Monte Carlo and Latin hypercube sampling techniques. Sensitivity analysis for each variable involved into the calibration was computed by the Sobol method, which is based on the analysis of the variance breakdown, and the Fourier amplitude sensitivity test method, which is based on Fourier's analysis. Sensitivity analysis is an essential tool in simulation modeling and for performing error propagation assessments.
NASA Astrophysics Data System (ADS)
Dai, Yanqiu; Xu, Huimei; Wang, Haoyu; Lu, Yonghua; Wang, Pei
2018-06-01
We experimentally demonstrated a high sensitivity of surface plasmon resonance (SPR) sensor with silver rectangular grating coupling. The reflection spectra of the silver gratings indicated that surface plasmon resonance can be excited by either positive or negative order diffraction of the grating, depending on the period of the gratings. Comparing to prism-coupled SPR sensor, the sensitivities are higher for negative order diffraction coupling in bigger coupling angle, but much smaller for positive order diffraction coupling of the gratings. High sensitivity of 254.13 degree/RIU is experimentally realized by grating-based SPR sensor in the negative diffraction excitation mode. Our work paves the way for compact and sensitive SPR sensor in the applications of biochemical and gas sensing.
Stress-Related Alterations of Visceral Sensation: Animal Models for Irritable Bowel Syndrome Study
Mulak, Agata; Taché, Yvette
2011-01-01
Stressors of different psychological, physical or immune origin play a critical role in the pathophysiology of irritable bowel syndrome participating in symptoms onset, clinical presentation as well as treatment outcome. Experimental stress models applying a variety of acute and chronic exteroceptive or interoceptive stressors have been developed to target different periods throughout the lifespan of animals to assess the vulnerability, the trigger and perpetuating factors determining stress influence on visceral sensitivity and interactions within the brain-gut axis. Recent evidence points towards adequate construct and face validity of experimental models developed with respect to animals' age, sex, strain differences and specific methodological aspects such as non-invasive monitoring of visceromotor response to colorectal distension as being essential in successful identification and evaluation of novel therapeutic targets aimed at reducing stress-related alterations in visceral sensitivity. Underlying mechanisms of stress-induced modulation of visceral pain involve a combination of peripheral, spinal and supraspinal sensitization based on the nature of the stressors and dysregulation of descending pathways that modulate nociceptive transmission or stress-related analgesic response. PMID:21860814
NASA Astrophysics Data System (ADS)
Denisov, Alexander; Gudkov, Alexander; Qiu, Jing Hui
2014-10-01
Josephson junction (JJ) can be used as the criterion in single-block super wide band frequency-meter and as the sensitive element in the super wide band panoramic receiver. There presented the theoretical and experimental investigations and described the innovation decision about to combine both devices in one new microwave device. JJ in this case works in self-pump mode regime. New device can be especially convenient for the experimental purposes with new generation structures when radiated power is small and frequency are unknown correctly.
Detailed mechanism of benzene oxidation
NASA Technical Reports Server (NTRS)
Bittker, David A.
1987-01-01
A detailed quantitative mechanism for the oxidation of benzene in both argon and nitrogen diluted systems is presented. Computed ignition delay time for argon diluted mixtures are in satisfactory agreement with experimental results for a wide range of initial conditions. An experimental temperature versus time profile for a nitrogen diluted oxidation was accurately matched and several concentration profiles were matched qualitatively. Application of sensitivity analysis has given approximate rate constant expressions for the two dominant heat release reactions, the oxidation of C6H5 and C5H5 radicals by molecular oxygen.
Li, Zhonghui; Jones, Yolanda; Hossenlopp, Jeanne; Cernosek, Richard; Josse, Fabien
2005-07-15
Direct chemical sensing in liquid environments using polymer-guided shear horizontal surface acoustic wave sensor platforms on 36 degrees rotated Y-cut LiTaO3 is investigated. Design considerations for optimizing these devices for liquid-phase detection are systematically explored. Two different sensor geometries are experimentally and theoretically analyzed. Dual delay line devices are used with a reference line coated with poly (methyl methacrylate) (PMMA) and a sensing line coated with a chemically sensitive polymer, which acts as both a guiding layer and a sensing layer or with a PMMA waveguide and a chemically sensitive polymer. Results show the three-layer model provides higher sensitivity than the four-layer model. Contributions from mass loading and coating viscoelasticity changes to the sensor response are evaluated, taking into account the added mass, swelling, and plasticization. Chemically sensitive polymers are investigated in the detection of low concentrations (1-60 ppm) of toluene, ethylbenzene, and xylenes in water. A low-ppb level detection limit is estimated from the present experimental measurements. Sensor properties are investigated by varying the sensor geometries, coating thickness combinations, coating properties, and curing temperature for operation in liquid environments. Partition coefficients for polymer-aqueous analyte pairs are used to explain the observed trend in sensitivity for the polymers PMMA, poly(isobutylene), poly(epichlorohydrin), and poly(ethyl acrylate) used in this work.
Ahn, Hyochol; Weaver, Michael; Lyon, Debra; Kim, Junglyun; Choi, Eunyoung; Staud, Roland; Fillingim, Roger B.
2016-01-01
Objective Ethnicity has been associated with clinical and experimental pain responses. While ethnic disparities in pain in other minority groups compared to whites are well described, pain in Asian Americans remains poorly understood. The purpose of this study was to characterize differences in clinical pain intensity and experimental pain sensitivity among older Asian American and non-Hispanic White (NHW) participants with knee osteoarthritis (OA). Methods Data were collected from 50 Asian Americans ages 45-85 (28 Korean, 9 Chinese, 7 Japanese, 5 Filipino, and 1 Indian) and compared to 50 age- and gender-matched NHW individuals with symptomatic knee OA pain. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Graded Chronic Pain Scale (GCPS) were used to assess the intensity of clinical knee pain. In addition, quantitative sensory testing was used to measure experimental sensitivity to heat- and mechanically-induced pain. Results Asian American participants had significantly higher levels of clinical pain intensity than NHW participants with knee OA. In addition, Asian American participants had significantly higher experimental pain sensitivity than NHW participants with knee OA. Discussion These findings add to the growing literature regarding ethnic and racial differences in clinical pain intensity and experimental pain sensitivity. Asian Americans in particular may be at risk for clinical pain and heightened experimental pain sensitivity. Further investigation is needed to identify the mechanisms underlying ethnic group differences in pain between Asian Americans and non-Hispanic Whites, and to ensure that ethnic group disparities in pain are ameliorated. PMID:28060784
Oliveira, Denize; Ares, Gastón; Deliza, Rosires
2018-06-01
Sugar reduction in beverages can contribute to reduce consumption of this nutrient and to improve the health status of the population. However, such reduction can negatively affect consumer perception. Label information can be an effective tool to increase consumer interest in sugar-reduced products. In this context, the aim of the present work was to study the influence of health/hedonic claims on consumer hedonic and sensory perception of sugar reduction in orange/passionfruit nectars under expected and informed conditions. Sugar-reduced orange/passionfruit nectars (20% and 40% reduced in added sugar) featuring different claims (none, health claim or hedonic claim) were evaluated, together with a control product without reduction. Following a between-subjects experimental design, 206 participants evaluated the nectars under two experimental conditions: (a) expected, looking at the packages, and (b) informed, looking at the packages and tasting the nectars. In each experimental condition, participants evaluated their overall liking using a 9-point hedonic scale and answered a check-all-that-apply questions related to the sensory characteristics of the nectars. Results showed that although consumers did not have negative expectations about sugar-reduced nectars, the sensory characteristics of the products were the main determinants of consumers' hedonic reaction towards the nectars. The influence of claims on consumers' perception was modulated by their hedonic sensitivity towards sugar-reduction. The hedonic claim increased overall liking of those consumers with low hedonic sensitivity towards sugar reduction, whereas it had the opposite effect on the most sensitive consumers. Results from the present work suggest that although hedonic claims hold potential for a consumer segment, care must be taken to avoid the generation of unrealistic expectations about the sensory characteristics of sugar-reduced products. Copyright © 2018 Elsevier Ltd. All rights reserved.
A comparison of solute-transport solution techniques based on inverse modelling results
Mehl, S.; Hill, M.C.
2000-01-01
Five common numerical techniques (finite difference, predictor-corrector, total-variation-diminishing, method-of-characteristics, and modified-method-of-characteristics) were tested using simulations of a controlled conservative tracer-test experiment through a heterogeneous, two-dimensional sand tank. The experimental facility was constructed using randomly distributed homogeneous blocks of five sand types. This experimental model provides an outstanding opportunity to compare the solution techniques because of the heterogeneous hydraulic conductivity distribution of known structure, and the availability of detailed measurements with which to compare simulated concentrations. The present work uses this opportunity to investigate how three common types of results-simulated breakthrough curves, sensitivity analysis, and calibrated parameter values-change in this heterogeneous situation, given the different methods of simulating solute transport. The results show that simulated peak concentrations, even at very fine grid spacings, varied because of different amounts of numerical dispersion. Sensitivity analysis results were robust in that they were independent of the solution technique. They revealed extreme correlation between hydraulic conductivity and porosity, and that the breakthrough curve data did not provide enough information about the dispersivities to estimate individual values for the five sands. However, estimated hydraulic conductivity values are significantly influenced by both the large possible variations in model dispersion and the amount of numerical dispersion present in the solution technique.Five common numerical techniques (finite difference, predictor-corrector, total-variation-diminishing, method-of-characteristics, and modified-method-of-characteristics) were tested using simulations of a controlled conservative tracer-test experiment through a heterogeneous, two-dimensional sand tank. The experimental facility was constructed using randomly distributed homogeneous blocks of five sand types. This experimental model provides an outstanding opportunity to compare the solution techniques because of the heterogeneous hydraulic conductivity distribution of known structure, and the availability of detailed measurements with which to compare simulated concentrations. The present work uses this opportunity to investigate how three common types of results - simulated breakthrough curves, sensitivity analysis, and calibrated parameter values - change in this heterogeneous situation, given the different methods of simulating solute transport. The results show that simulated peak concentrations, even at very fine grid spacings, varied because of different amounts of numerical dispersion. Sensitivity analysis results were robust in that they were independent of the solution technique. They revealed extreme correlation between hydraulic conductivity and porosity, and that the breakthrough curve data did not provide enough information about the dispersivities to estimate individual values for the five sands. However, estimated hydraulic conductivity values are significantly influenced by both the large possible variations in model dispersion and the amount of numerical dispersion present in the solution technique.
Application of Anaerobic Digestion Model No. 1 for simulating anaerobic mesophilic sludge digestion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendes, Carlos, E-mail: carllosmendez@gmail.com; Esquerre, Karla, E-mail: karlaesquerre@ufba.br; Matos Queiroz, Luciano, E-mail: lmqueiroz@ufba.br
2015-01-15
Highlights: • The behavior of a anaerobic reactor was evaluated through modeling. • Parametric sensitivity analysis was used to select most sensitive of the ADM1. • The results indicate that the ADM1 was able to predict the experimental results. • Organic load rate above of 35 kg/m{sup 3} day affects the performance of the process. - Abstract: Improving anaerobic digestion of sewage sludge by monitoring common indicators such as volatile fatty acids (VFAs), gas composition and pH is a suitable solution for better sludge management. Modeling is an important tool to assess and to predict process performance. The present studymore » focuses on the application of the Anaerobic Digestion Model No. 1 (ADM1) to simulate the dynamic behavior of a reactor fed with sewage sludge under mesophilic conditions. Parametric sensitivity analysis is used to select the most sensitive ADM1 parameters for estimation using a numerical procedure while other parameters are applied without any modification to the original values presented in the ADM1 report. The results indicate that the ADM1 model after parameter estimation was able to predict the experimental results of effluent acetate, propionate, composites and biogas flows and pH with reasonable accuracy. The simulation of the effect of organic shock loading clearly showed that an organic shock loading rate above of 35 kg/m{sup 3} day affects the performance of the reactor. The results demonstrate that simulations can be helpful to support decisions on predicting the anaerobic digestion process of sewage sludge.« less
Inpainting approaches to fill in detector gaps in phase contrast computed tomography
NASA Astrophysics Data System (ADS)
Brun, F.; Delogu, P.; Longo, R.; Dreossi, D.; Rigon, L.
2018-01-01
Photon counting semiconductor detectors in radiation imaging present attractive properties, such as high efficiency, low noise, and energy sensitivity. The very complex electronics limits the sensitive area of current devices to a few square cm. This disadvantage is often compensated by tiling a larger matrix with an adequate number of detector units but this usually results in non-negligible insensitive gaps between two adjacent modules. When considering the case of Computed Tomography (CT), these gaps lead to degraded reconstructed images with severe streak and ring artifacts. This work presents two digital image processing solutions to fill in these gaps when considering the specific case of synchrotron radiation x-ray parallel beam phase contrast CT. While not discussed with experimental data, other CT modalities, such as spectral, cone beam and other geometries might benefit from the presented approaches.
Sensitivity analysis for oblique incidence reflectometry using Monte Carlo simulations.
Kamran, Faisal; Andersen, Peter E
2015-08-10
Oblique incidence reflectometry has developed into an effective, noncontact, and noninvasive measurement technology for the quantification of both the reduced scattering and absorption coefficients of a sample. The optical properties are deduced by analyzing only the shape of the reflectance profiles. This article presents a sensitivity analysis of the technique in turbid media. Monte Carlo simulations are used to investigate the technique and its potential to distinguish the small changes between different levels of scattering. We present various regions of the dynamic range of optical properties in which system demands vary to be able to detect subtle changes in the structure of the medium, translated as measured optical properties. Effects of variation in anisotropy are discussed and results presented. Finally, experimental data of milk products with different fat content are considered as examples for comparison.
Uncertainty of Videogrammetric Techniques used for Aerodynamic Testing
NASA Technical Reports Server (NTRS)
Burner, A. W.; Liu, Tianshu; DeLoach, Richard
2002-01-01
The uncertainty of videogrammetric techniques used for the measurement of static aeroelastic wind tunnel model deformation and wind tunnel model pitch angle is discussed. Sensitivity analyses and geometrical considerations of uncertainty are augmented by analyses of experimental data in which videogrammetric angle measurements were taken simultaneously with precision servo accelerometers corrected for dynamics. An analysis of variance (ANOVA) to examine error dependence on angle of attack, sensor used (inertial or optical). and on tunnel state variables such as Mach number is presented. Experimental comparisons with a high-accuracy indexing table are presented. Small roll angles are found to introduce a zero-shift in the measured angles. It is shown experimentally that. provided the proper constraints necessary for a solution are met, a single- camera solution can he comparable to a 2-camera intersection result. The relative immunity of optical techniques to dynamics is illustrated.
NASA Technical Reports Server (NTRS)
Sorensen, Ira J.
1998-01-01
The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.
NASA Technical Reports Server (NTRS)
Nicks, C. O.; Childs, D. W.
1984-01-01
The importance of seal behavior in rotordynamics is discussed and current annular seal theory is reviewed. A Nelson's analytical-computational method for determining rotordynamic coefficients for this type of compressible-flow seal is outlined. Various means for the experimental identification of the dynamic coefficients are given, and the method employed at the Texas A and M University (TAMU) test facility is explained. The TAMU test apparatus is described, and the test procedures are discussed. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and rotordynamic coefficients for a smooth and a honeycomb constant-clearance seal are presented and compared to theoretical results from Nelson's analysis. The results for both seals show little sensitivity to the running speed over the test range. Agreement between test results and theory for leakage through the seal is satisfactory. Test results for direct stiffness show a greater sensitivity to fluid pre-rotation than predicted. Results also indicate that the deliberately roughened surface of the honeycomb seal provides improved stability versus the smooth seal.
Scheiblauer, Johannes; Scheiner, Stefan; Joksch, Martin; Kavsek, Barbara
2018-09-14
A combined experimental/theoretical approach is presented, for improving the predictability of Saccharomyces cerevisiae fermentations. In particular, a mathematical model was developed explicitly taking into account the main mechanisms of the fermentation process, allowing for continuous computation of key process variables, including the biomass concentration and the respiratory quotient (RQ). For model calibration and experimental validation, batch and fed-batch fermentations were carried out. Comparison of the model-predicted biomass concentrations and RQ developments with the corresponding experimentally recorded values shows a remarkably good agreement for both batch and fed-batch processes, confirming the adequacy of the model. Furthermore, sensitivity studies were performed, in order to identify model parameters whose variations have significant effects on the model predictions: our model responds with significant sensitivity to the variations of only six parameters. These studies provide a valuable basis for model reduction, as also demonstrated in this paper. Finally, optimization-based parametric studies demonstrate how our model can be utilized for improving the efficiency of Saccharomyces cerevisiae fermentations. Copyright © 2018 Elsevier Ltd. All rights reserved.
Investigating the thermally induced acoustoelastic effect in isotropic media with Lamb waves
Dodson, Jacob C.; Inman, Daniel J.
2014-01-01
Elastic wave velocities in metallic structures are affected by variations in environmental conditions such as changing temperature. This paper extends the theory of acoustoelasticity by allowing thermally induced strains in unconstrained isotropic media, and it experimentally examines the velocity variation of Lamb waves in aluminum plates (AL-6061) due to isothermal temperature deviations. This paper presents both thermally induced acoustoelastic constants and thermally varying effective Young's modulus and Poisson's ratio which include the third order elastic material constants. The experimental thermal sensitivity of the phase velocity (∂vP/∂θ) for both the symmetric and antisymmetric modes are bounded by two theories, the acoustoelastic Lamb wave theory with thermo-acoustoelastic tensors and the thermoelastic Lamb wave theory using an effective thermo-acoustoelastic moduli. This paper shows the theoretical thermally induced acoustoelastic Lamb wave thermal sensitivity (∂vP/∂θ) is an upper bound approximation of the experimental thermal changes, but the acoustoelastic Lamb wave theory is not valid for predicting the antisymmetric (A0) phase velocity at low frequency-thickness values, <1.55 MHz mm for various temperatures. PMID:25373955
Status of the MARE experiment in Milan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferri, E.; Arnaboldi, C.; Ceruti, G.
2009-12-16
An international collaboration has grown around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for a direct and calorimetric measurement of the electron antineutrino mass with sub-electronvolt sensitivity.MARE is divided into two phases. The first phase (MARE-1) consists of two independent experiments using the presently available detector technology to reach a sensitivity of m{sub v}{<=}2eV/c{sup 2}. The goal of the second phase (MARE-2) is to achieve a sub-electronvolt sensitivity on the neutrino mass.The Milan MARE-1 experiment is based on arrays of silicon implanted microcalorimeters, produced by NASA/GSFC, with dielectric silver perrhenate absorbers, AgReO{sub 4}. We present here themore » status of MARE-1 in Milan which is starting data taking with 2 arrays (72 detectors). In this configuration a sensitivity of about 5 eV can be achieved in two years. We describe in details the experimental setup which is designed to host up to 8 arrays (288 detectors). With 8 arrays, two years of measurement would improve the sensitivity to about 3 eV. This talk reports on the activity of the group for the MARE project in Milan.« less
Ultra-sensitive magnetic microscopy with an atomic magnetometer and flux guides
NASA Astrophysics Data System (ADS)
Kim, Young Jin; Savukov, Igor
Many applications in neuroscience, biomedical research, and material science require high-sensitivity, high-resolution magnetometry. In order to meet this need we recently combined a cm-size spin-exchange relaxation-free Atomic Magnetometer (AM) with a flux guide (FG) to produce ultra-sensitive FG-AM magnetic microscopy. The FG serves to transmit the target magnetic flux to the AM thus enhancing both the sensitivity and resolution to tiny magnetic objects. In this talk, we will describe existing and next generation FG-AM devices and present experimental and numerical tests of its sensitivity and resolution. We demonstrate that an optimized FG-AM has sufficient resolution and sensitivity for the detection of a small number of neurons, which would be an important milestone in neuroscience. In addition, as a demonstration of one possible application of the FG-AM device, we conducted high-resolution magnetic imaging of micron-size magnetic particles. We will show that the device can produce clear microscopic magnetic image of 10 μm-size magnetic particles.
Experimental demonstration of photon upconversion via cooperative energy pooling
Weingarten, Daniel H.; LaCount, Michael D.; van de Lagemaat, Jao; ...
2017-03-15
Photon upconversion is a fundamental interaction of light and matter that has applications in fields ranging from bioimaging to microfabrication. However, all photon upconversion methods demonstrated thus far involve challenging aspects, including requirements of high excitation intensities, degradation in ambient air, requirements of exotic materials or phases, or involvement of inherent energy loss processes. Here we experimentally demonstrate a mechanism of photon upconversion in a thin film, binary mixture of organic chromophores that provides a pathway to overcoming the aforementioned disadvantages. This singlet-based process, called Cooperative Energy Pooling (CEP), utilizes a sensitizer-acceptor design in which multiple photoexcited sensitizers resonantly andmore » simultaneously transfer their energies to a higher-energy state on a single acceptor. Data from this proof-of-concept implementation is fit by a proposed model of the CEP process. As a result, design guidelines are presented to facilitate further research and development of more optimized CEP systems.« less
Models for Total-Dose Radiation Effects in Non-Volatile Memory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, Philip Montgomery; Wix, Steven D.
The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models andmore » compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.« less
Experimental demonstration of photon upconversion via cooperative energy pooling
Weingarten, Daniel H.; LaCount, Michael D.; van de Lagemaat, Jao; Rumbles, Garry; Lusk, Mark T.; Shaheen, Sean E.
2017-01-01
Photon upconversion is a fundamental interaction of light and matter that has applications in fields ranging from bioimaging to microfabrication. However, all photon upconversion methods demonstrated thus far involve challenging aspects, including requirements of high excitation intensities, degradation in ambient air, requirements of exotic materials or phases, or involvement of inherent energy loss processes. Here we experimentally demonstrate a mechanism of photon upconversion in a thin film, binary mixture of organic chromophores that provides a pathway to overcoming the aforementioned disadvantages. This singlet-based process, called Cooperative Energy Pooling (CEP), utilizes a sensitizer-acceptor design in which multiple photoexcited sensitizers resonantly and simultaneously transfer their energies to a higher-energy state on a single acceptor. Data from this proof-of-concept implementation is fit by a proposed model of the CEP process. Design guidelines are presented to facilitate further research and development of more optimized CEP systems. PMID:28294129
NASA Astrophysics Data System (ADS)
Lin, W.; Ren, P.; Zheng, H.; Liu, X.; Huang, M.; Wada, R.; Qu, G.
2018-05-01
The experimental measures of the multiplicity derivatives—the moment parameters, the bimodal parameter, the fluctuation of maximum fragment charge number (normalized variance of Zmax, or NVZ), the Fisher exponent (τ ), and the Zipf law parameter (ξ )—are examined to search for the liquid-gas phase transition in nuclear multifragmention processes within the framework of the statistical multifragmentation model (SMM). The sensitivities of these measures are studied. All these measures predict a critical signature at or near to the critical point both for the primary and secondary fragments. Among these measures, the total multiplicity derivative and the NVZ provide accurate measures for the critical point from the final cold fragments as well as the primary fragments. The present study will provide a guide for future experiments and analyses in the study of the nuclear liquid-gas phase transition.
Experimental demonstration of photon upconversion via cooperative energy pooling
NASA Astrophysics Data System (ADS)
Weingarten, Daniel H.; Lacount, Michael D.; van de Lagemaat, Jao; Rumbles, Garry; Lusk, Mark T.; Shaheen, Sean E.
2017-03-01
Photon upconversion is a fundamental interaction of light and matter that has applications in fields ranging from bioimaging to microfabrication. However, all photon upconversion methods demonstrated thus far involve challenging aspects, including requirements of high excitation intensities, degradation in ambient air, requirements of exotic materials or phases, or involvement of inherent energy loss processes. Here we experimentally demonstrate a mechanism of photon upconversion in a thin film, binary mixture of organic chromophores that provides a pathway to overcoming the aforementioned disadvantages. This singlet-based process, called Cooperative Energy Pooling (CEP), utilizes a sensitizer-acceptor design in which multiple photoexcited sensitizers resonantly and simultaneously transfer their energies to a higher-energy state on a single acceptor. Data from this proof-of-concept implementation is fit by a proposed model of the CEP process. Design guidelines are presented to facilitate further research and development of more optimized CEP systems.
Fabrication and characterization of polyaniline/PVA humidity microsensors.
Yang, Ming-Zhi; Dai, Ching-Liang; Lin, Wei-Yi
2011-01-01
This study presents the fabrication and characterization of a humidity microsensor that consists of interdigitated electrodes and a sensitive film. The area of the humidity microsensor is about 2 mm(2). The sensitive film is polyaniline doping polyvinyl alcohol (PVA) that is prepared by the sol-gel method, and the film has nanofiber and porous structures that help increase the sensing reaction. The commercial 0.35 μm Complimentary Metal Oxide Semiconductor (CMOS) process is used to fabricate the humidity microsensor. The sensor needs a post-CMOS process to etch the sacrificial layer and to coat the sensitive film on the interdigitated electrodes. The sensor produces a change in resistance as the polyaniline/PVA film absorbs or desorbs vapor. Experimental results show that the sensitivity of the humidity sensor is about 12.6 kΩ/%RH at 25 °C.
Instrument performance of a radon measuring system with the alpha-track detection technique.
Tokonami, S; Zhuo, W; Ryuo, H; Yonehara, H; Yamada, Y; Shimo, M
2003-01-01
An instrument performance test has been carried out for a radon measuring system made in Hungary. The system measures radon using the alpha-track detection technique. It consists of three parts: the passive detector, the etching unit and the evaluation unit. A CR-39 detector is used as the radiation detector. Alpha-track reading and data analysis are carried out after chemical etching. The following subjects were examined in the present study: (1) radon sensitivity, (2) performance of etching and evaluation processes and (3) thoron sensitivity. The radon sensitivity of 6.9 x 10(-4) mm(-2) (Bq m(-3) d)(-1) was acceptable for practical application. The thoron sensitivity was estimated to be as low as 3.3 x 10(-5) mm(-2) (Bq m(-3) d)(-1) from the experimental study.
Silver halide sensitized gelatin derived from BB-640 holographic emulsion.
Neipp, C; Pascual, I; Beléndez, A
1999-03-10
Silver halide sensitized gelatin (SHSG) is one of the most interesting techniques for the production of holographic optical elements, achieving relatively high sensitivity of photographic material with a low scattering of dichromated gelatin. Here we present experimental results for SHSG derived from the novel BB-640, a red-sensitive ultra-fine-grain emulsion from Holographic Recording Technologies (Steinau, Germany). The material is characterized before recording and after processing, and information about the thickness, absorption, and refractive-index modulation of the final holograms is obtained. The influence of the developer is analyzed, and diffraction efficiencies as great as 96.2% (after allowing for reflections) with a transmission of 1% and absorption and scatter losses of 2.8% are obtained with AAC developer. Our investigations reveal that high-quality SHSG transmission holograms may be obtained with the new BB-640 plates.
NASA Astrophysics Data System (ADS)
Kim, Dokyun; Bravo, Luis; Matusik, Katarzyna; Duke, Daniel; Kastengren, Alan; Swantek, Andy; Powell, Christopher; Ham, Frank
2016-11-01
One of the major concerns in modern direct injection engines is the sensitivity of engine performance to fuel characteristics. Recent works have shown that even slight differences in fuel properties can cause significant changes in efficiency and emission of an engine. Since the combustion process is very sensitive to the fuel/air mixture formation resulting from disintegration of liquid jet, the precise assessment of fuel sensitivity on liquid jet atomization process is required first to study the impact of different fuels on the combustion. In the present study, the breaking process of a liquid jet from a diesel injector injecting into a quiescent gas chamber is investigated numerically and experimentally for different liquid fuels (n-dodecane, iso-octane, CAT A2 and C3). The unsplit geometric Volume-of-Fluid method is employed to capture the phase interface in Large-eddy simulations and results are compared against the radiography measurement from Argonne National Lab including jet penetration, liquid mass distribution and volume fraction. The breakup characteristics will be shown for different fuels as well as droplet PDF statistics to demonstrate the influences of the physical properties on the primary atomization of liquid jet. Supported by HPCMP FRONTIER award, US DOD, Office of the Army.
Jahanian, Hesamoddin; Soltanian-Zadeh, Hamid; Hossein-Zadeh, Gholam-Ali
2005-09-01
To present novel feature spaces, based on multiscale decompositions obtained by scalar wavelet and multiwavelet transforms, to remedy problems associated with high dimension of functional magnetic resonance imaging (fMRI) time series (when they are used directly in clustering algorithms) and their poor signal-to-noise ratio (SNR) that limits accurate classification of fMRI time series according to their activation contents. Using randomization, the proposed method finds wavelet/multiwavelet coefficients that represent the activation content of fMRI time series and combines them to define new feature spaces. Using simulated and experimental fMRI data sets, the proposed feature spaces are compared to the cross-correlation (CC) feature space and their performances are evaluated. In these studies, the false positive detection rate is controlled using randomization. To compare different methods, several points of the receiver operating characteristics (ROC) curves, using simulated data, are estimated and compared. The proposed features suppress the effects of confounding signals and improve activation detection sensitivity. Experimental results show improved sensitivity and robustness of the proposed method compared to the conventional CC analysis. More accurate and sensitive activation detection can be achieved using the proposed feature spaces compared to CC feature space. Multiwavelet features show superior detection sensitivity compared to the scalar wavelet features. (c) 2005 Wiley-Liss, Inc.
Impact of early life adversity on EMG stress reactivity of the trapezius muscle
Luijcks, Rosan; Vossen, Catherine J.; Roggeveen, Suzanne; van Os, Jim; Hermens, Hermie J.; Lousberg, Richel
2016-01-01
Abstract Human and animal research indicates that exposure to early life adversity increases stress sensitivity later in life. While behavioral markers of adversity-induced stress sensitivity have been suggested, physiological markers remain to be elucidated. It is known that trapezius muscle activity increases during stressful situations. The present study examined to what degree early life adverse events experienced during early childhood (0–11 years) and adolescence (12–17 years) moderate experimentally induced electromyographic (EMG) stress activity of the trapezius muscles, in an experimental setting. In a general population sample (n = 115), an anticipatory stress effect was generated by presenting a single unpredictable and uncontrollable electrical painful stimulus at t = 3 minutes. Subjects were unaware of the precise moment of stimulus delivery and its intensity level. Linear and nonlinear time courses in EMG activity were modeled using multilevel analysis. The study protocol included 2 experimental sessions (t = 0 and t = 6 months) allowing for examination of reliability. Results show that EMG stress reactivity during the stress paradigm was consistently stronger in people with higher levels of early life adverse events; early childhood adversity had a stronger moderating effect than adolescent adversity. The impact of early life adversity on EMG stress reactivity may represent a reliable facet that can be used in both clinical and nonclinical studies. PMID:27684800
Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study
Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca
2015-01-01
Abstract. Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at ±120 deg with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies. PMID:26839910
Wokosin, David L.; Squirrell, Jayne M.; Eliceiri, Kevin W.; White, John G.
2008-01-01
Experimental laser microbeam techniques have become established tools for studying living specimens. A steerable, focused laser beam may be used for a variety of experimental manipulations such as laser microsurgery, optical trapping, localized photolysis of caged bioactive probes, and patterned photobleaching. Typically, purpose-designed experimental systems have been constructed for each of these applications. In order to assess the consequences of such experimental optical interventions, long-term, microscopic observation of the specimen is often required. Multiphoton excitation, because of its ability to obtain high-contrast images from deep within a specimen with minimal phototoxic effects, is a preferred technique for in vivo imaging. An optical workstation is described that combines the functionality of an experimental optical microbeam apparatus with a sensitive multiphoton imaging system designed for use with living specimens. Design considerations are discussed and examples of ongoing biological applications are presented. The integrated optical workstation concept offers advantages in terms of flexibility and versatility relative to systems implemented with separate imaging and experimental components. PMID:18607511
NASA Astrophysics Data System (ADS)
Wokosin, David L.; Squirrell, Jayne M.; Eliceiri, Kevin W.; White, John G.
2003-01-01
Experimental laser microbeam techniques have become established tools for studying living specimens. A steerable, focused laser beam may be used for a variety of experimental manipulations such as laser microsurgery, optical trapping, localized photolysis of caged bioactive probes, and patterned photobleaching. Typically, purpose-designed experimental systems have been constructed for each of these applications. In order to assess the consequences of such experimental optical interventions, long-term, microscopic observation of the specimen is often required. Multiphoton excitation, because of its ability to obtain high-contrast images from deep within a specimen with minimal phototoxic effects, is a preferred technique for in vivo imaging. An optical workstation is described that combines the functionality of an experimental optical microbeam apparatus with a sensitive multiphoton imaging system designed for use with living specimens. Design considerations are discussed and examples of ongoing biological applications are presented. The integrated optical workstation concept offers advantages in terms of flexibility and versatility relative to systems implemented with separate imaging and experimental components.
Liu, Jun; Wang, Jian
2015-01-01
We present a simple configuration incorporating a single polarization-sensitive phase-only liquid crystal spatial light modulator (LC-SLM) to facilitate polarization-insensitive spatial light modulation. The polarization-insensitive configuration is formed by a polarization beam splitter (PBS), a polarization-sensitive phase-only LC-SLM, a half-wave plate (HWP), and a mirror in a loop structure. We experimentally demonstrate polarization-insensitive spatial light modulations for incident linearly polarized beams with different polarization states and polarization-multiplexed beams. Polarization-insensitive spatial light modulations generating orbital angular momentum (OAM) beams are demonstrated in the experiment. The designed polarization-insensitive configuration may find promising applications in spatial light modulations accommodating diverse incident polarizations. PMID:26146032
Design and Application of a Collocated Capacitance Sensor for Magnetic Bearing Spindle
NASA Technical Reports Server (NTRS)
Shin, Dongwon; Liu, Seon-Jung; Kim, Jongwon
1996-01-01
This paper presents a collocated capacitance sensor for magnetic bearings. The main feature of the sensor is that it is made of a specific compact printed circuit board (PCB). The signal processing unit has been also developed. The results of the experimental performance evaluation on the sensitivity, resolution and frequency response of the sensor are presented. Finally, an application example of the sensor to the active control of a magnetic bearing is described.
Deep Flaw Detection with Giant Magnetoresistive (GMR) Based Self-Nulling Probe
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Namkung, Min
2004-01-01
In this paper a design modification to the Very-Low Frequency GMR Based Self-Nulling Probe has been presented to enable improved signal to noise ratio for deeply buried flaws. The design change consists of incorporating a feedback coil in the center of the flux focusing lens. The use of the feedback coil enables cancellation of the leakage fields in the center of the probe and biasing of the GMR sensor to a location of high magnetic field sensitivity. The effect of the feedback on the probe output was examined, and experimental results for deep flaw detection were presented. The experimental results show that the modified probe is capable of clearly identifying flaws up to 1 cm deep in aluminum alloy structures.
Cause and cure of sloppiness in ordinary differential equation models.
Tönsing, Christian; Timmer, Jens; Kreutz, Clemens
2014-08-01
Data-based mathematical modeling of biochemical reaction networks, e.g., by nonlinear ordinary differential equation (ODE) models, has been successfully applied. In this context, parameter estimation and uncertainty analysis is a major task in order to assess the quality of the description of the system by the model. Recently, a broadened eigenvalue spectrum of the Hessian matrix of the objective function covering orders of magnitudes was observed and has been termed as sloppiness. In this work, we investigate the origin of sloppiness from structures in the sensitivity matrix arising from the properties of the model topology and the experimental design. Furthermore, we present strategies using optimal experimental design methods in order to circumvent the sloppiness issue and present nonsloppy designs for a benchmark model.
Fission in the landscape of heaviest elements: Some recent examples
NASA Astrophysics Data System (ADS)
Khuyagbaatar, J.; Yakushev, A.; Düllmann, Ch. E.; Ackermann, D.; Andersson, L.-L.; Block, M.; Brand, H.; Even, J.; Forsberg, U.; Hartmann, W.; Herzberg, R.-D.; Heßberger, F. P.; Hoffmann, J.; Hübner, A.; Jäger, E.; Jeppsson, J.; Kindler, B.; Kratz, J. V.; Krier, J.; Kurz, N.; Lommel, B.; Maiti, M.; Minami, S.; Rudolph, D.; Runke, J.; Sarmiento, L. G.; Schädel, M.; Schausten, B.; Steiner, J.; Heidenreich, T. Torres De; Uusitalo, J.; Wiehl, N.; Yakusheva, V.
2016-12-01
The fission process still remains a main factor that determines the stability of the atomic nucleus of heaviest elements. Fission half-lives vary over a wide range, 10-19-1024 s. Present experimental techniques for the synthesis of the superheavy elements that usually measure α-decay chains are sensitive only in a limited range of half-lives, often 10-5-103 s. In the past years, measurement techniques for very short-lived and very long-lived nuclei were significantly improved at the gas-filled recoil separator TASCA at GSI Darmstadt. Recently, several experimental studies of fission-related phenomena have successfully been performed. In this paper, results on 254-256Rf and 266Lr are presented and corresponding factors for retarding the fission process are discussed.
Rapidity dependence in holographic heavy ion collisions
Wilke van der Schee; Schenke, Bjorn
2015-12-11
We present an attempt to closely mimic the initial stage of heavy ion collisions within holography, assuming a decoupling of longitudinal and transverse dynamics in the very early stage. We subsequently evolve the obtained initial state using state-of-the-art hydrodynamic simulations and compare results with experimental data. We present results for charged hadron pseudorapidity spectra and directed and elliptic flow as functions of pseudorapidity for √s NN = 200GeV Au-Au and 2.76TeV Pb-Pb collisions. As a result, the directed flow interestingly turns out to be quite sensitive to the viscosity. The results can explain qualitative features of the collisions, but themore » rapidity spectra in our current model is narrower than the experimental data.« less
Cause and cure of sloppiness in ordinary differential equation models
NASA Astrophysics Data System (ADS)
Tönsing, Christian; Timmer, Jens; Kreutz, Clemens
2014-08-01
Data-based mathematical modeling of biochemical reaction networks, e.g., by nonlinear ordinary differential equation (ODE) models, has been successfully applied. In this context, parameter estimation and uncertainty analysis is a major task in order to assess the quality of the description of the system by the model. Recently, a broadened eigenvalue spectrum of the Hessian matrix of the objective function covering orders of magnitudes was observed and has been termed as sloppiness. In this work, we investigate the origin of sloppiness from structures in the sensitivity matrix arising from the properties of the model topology and the experimental design. Furthermore, we present strategies using optimal experimental design methods in order to circumvent the sloppiness issue and present nonsloppy designs for a benchmark model.
Microfabrication and Applications of Opto-Microfluidic Sensors
Zhang, Daiying; Men, Liqiu; Chen, Qiying
2011-01-01
A review of research activities on opto-microfluidic sensors carried out by the research groups in Canada is presented. After a brief introduction of this exciting research field, detailed discussion is focused on different techniques for the fabrication of opto-microfluidic sensors, and various applications of these devices for bioanalysis, chemical detection, and optical measurement. Our current research on femtosecond laser microfabrication of optofluidic devices is introduced and some experimental results are elaborated. The research on opto-microfluidics provides highly sensitive opto-microfluidic sensors for practical applications with significant advantages of portability, efficiency, sensitivity, versatility, and low cost. PMID:22163904
Turbulence model sensitivity and scour gap effect of unsteady flow around pipe: a CFD study.
Ali, Abbod; Sharma, R K; Ganesan, P; Akib, Shatirah
2014-01-01
A numerical investigation of incompressible and transient flow around circular pipe has been carried out at different five gap phases. Flow equations such as Navier-Stokes and continuity equations have been solved using finite volume method. Unsteady horizontal velocity and kinetic energy square root profiles are plotted using different turbulence models and their sensitivity is checked against published experimental results. Flow parameters such as horizontal velocity under pipe, pressure coefficient, wall shear stress, drag coefficient, and lift coefficient are studied and presented graphically to investigate the flow behavior around an immovable pipe and scoured bed.
NASA Astrophysics Data System (ADS)
Szewczyk, Dawid; Bauer, Andreas; Holt, Rune M.
2018-01-01
Knowledge about the stress sensitivity of elastic properties and velocities of shales is important for the interpretation of seismic time-lapse data taken as part of reservoir and caprock surveillance of both unconventional and conventional oil and gas fields (e.g. during 4-D monitoring of CO2 storage). Rock physics models are often developed based on laboratory measurements at ultrasonic frequencies. However, as shown previously, shales exhibit large seismic dispersion, and it is possible that stress sensitivities of velocities are also frequency dependent. In this work, we report on a series of seismic and ultrasonic laboratory tests in which the stress sensitivity of elastic properties of Mancos shale and Pierre shale I were investigated. The shales were tested at different water saturations. Dynamic rock engineering parameters and elastic wave velocities were examined on core plugs exposed to isotropic loading. Experiments were carried out in an apparatus allowing for static-compaction and dynamic measurements at seismic and ultrasonic frequencies within single test. For both shale types, we present and discuss experimental results that demonstrate dispersion and stress sensitivity of the rock stiffness, as well as P- and S-wave velocities, and stiffness anisotropy. Our experimental results show that the stress-sensitivity of shales is different at seismic and ultrasonic frequencies, which can be linked with simultaneously occurring changes in the dispersion with applied stress. Measured stress sensitivity of elastic properties for relatively dry samples was higher at seismic frequencies however, the increasing saturation of shales decreases the difference between seismic and ultrasonic stress-sensitivities, and for moist samples stress-sensitivity is higher at ultrasonic frequencies. Simultaneously, the increased saturation highly increases the dispersion in shales. We have also found that the stress-sensitivity is highly anisotropic in both shales and that in some of the cases higher stress-sensitivity of elastic properties can be seen in the direction parallel to the bedding plane.
Dynamic Characteristics and Stability Analysis of Space Shuttle Main Engine Oxygen Pump
NASA Technical Reports Server (NTRS)
Gunter, Edgar J.; Branagan, Lyle
1991-01-01
The dynamic characteristics of the Space Shuttle high pressure oxygen pump are presented. Experimental data is presented to show the vibration spectrum and response under actual engine operation and also in spin pit testing for balancing. The oxygen pump appears to be operating near a second critical speed and is sensitive to self excited aerodynamic cross coupling forces in the turbine and pump. An analysis is presented to show the improvement in pump stability by the application of turbulent flow seals, preburner seals, and pump shaft cross sectional modifications.
Atomic magnetometer-based ultra-sensitive magnetic microscopy
NASA Astrophysics Data System (ADS)
Kim, Young Jin; Savukov, Igor
2016-03-01
An atomic magnetometer (AM) based on lasers and alkali-metal vapor cells is currently the most sensitive non-cryogenic magnetic-field sensor. Many applications in neuroscience and other fields require high resolution, high sensitivity magnetic microscopic measurements. In order to meet this need we combined a cm-size spin-exchange relaxation-free AM with a flux guide (FG) to produce an ultra-sensitive FG-AM magnetic microscope. The FG serves to transmit the target magnetic flux to the AM thus enhancing both the sensitivity and resolution for tiny magnetic objects. In this talk, we will describe a prototype FG-AM device and present experimental and numerical tests of its sensitivity and resolution. We also demonstrate that an optimized FG-AM achieves high resolution and high sensitivity sufficient to detect a magnetic field of a single neuron in a few seconds, which would be an important milestone in neuroscience. We anticipate that this unique device can be applied to the detection of a single neuron, the detection of magnetic nano-particles, which in turn are very important for detection of target molecules in national security and medical diagnostics, and non-destructive testing.
Enhancing the sensitivity of slow light MZI biosensors through multi-hole defects
NASA Astrophysics Data System (ADS)
Qin, Kun; Zhao, Yiliang; Hu, Shuren; Weiss, Sharon M.
2018-02-01
We demonstrate enhanced detection sensitivity of a slow light Mach-Zehnder interferometer (MZI) sensor by incorporating multi-hole defects (MHDs). Slow light MZI biosensors with a one-dimensional photonic crystal in one arm have been previously shown to improve the performance of traditional MZI sensors based on the increased lightmatter interaction that takes place in the photonic crystal region of the structure. Introducing MHDs in the photonic crystal region increases the available surface area for molecular attachment and further increases the enhanced lightmatter interaction capability of slow light MZIs. The MHDs allow analyte to interact with a greater fraction of the guided wave in the MZI. For a slow light MHD MZI sensor with a 16 μm long sensing arm, a bulk sensitivity of 151,000 rad/RIU-cm is demonstrated experimentally, which is approximately two-fold higher than our previously reported slow light MZI sensors and thirteen-fold higher than traditional MZI biosensors with millimeter length sensing regions. For the label-free detection of nucleic acids, the slow light MZI with MHDs also exhibits a two-fold sensitivity improvement in experiment compared to the slow light MZI without MHDs. Because the detection sensitivity of slow light MHD MZIs scales with the length of the sensing arm, the tradeoff between detection limit and device size can be appropriately mitigated for different applications. All experimental results presented in this work are in good agreement with finite difference-time domain-calculations. Overall, the slow light MZI biosensors with MHDs are a promising platform for highly sensitive and multiplexed lab-on-chip systems.
Induction-detection electron spin resonance with spin sensitivity of a few tens of spins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artzi, Yaron; Twig, Ygal; Blank, Aharon
2015-02-23
Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity.more » This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.« less
Balloon-like singlemode-tapered multimode-singlemode fiber structure for refractive index sensing
NASA Astrophysics Data System (ADS)
Yang, Biyao; Niu, Yanxiong; Yang, Bowen; Dai, Lingling; Hu, Yanhui; Yin, Yiheng; Ding, Ming
2017-10-01
A novel high sensitivity refractive index sensor based on balloon-like singlemode-tapered multimode-singlemode (STMS) fiber structure has been proposed and experimentally demonstrated. Combining the tapering and bending endows the proposed sensor with large evanescent field, resulting in high sensitivity. Experimental results show that the proposed sensor has an average sensitivity of 1104.75 nm/RIU (RI Unit) in the range of 1.33-1.41 and a maximum sensitivity of 3374.50 nm/RIU at RI of 1.41.
Non-contact angle measurement based on parallel multiplex laser feedback interferometry
NASA Astrophysics Data System (ADS)
Zhang, Song; Tan, Yi-Dong; Zhang, Shu-Lian
2014-11-01
We present a novel precise angle measurement scheme based on parallel multiplex laser feedback interferometry (PLFI), which outputs two parallel laser beams and thus their displacement difference reflects the angle variation of the target. Due to its ultrahigh sensitivity to the feedback light, PLFI realizes the direct non-contact measurement of non-cooperative targets. Experimental results show that PLFI has an accuracy of 8″ within a range of 1400″. The yaw of a guide is also measured and the experimental results agree with those of the dual-frequency laser interferometer Agilent 5529A.
Application of a Laplace transform pair model for high-energy x-ray spectral reconstruction.
Archer, B R; Almond, P R; Wagner, L K
1985-01-01
A Laplace transform pair model, previously shown to accurately reconstruct x-ray spectra at diagnostic energies, has been applied to megavoltage energy beams. The inverse Laplace transforms of 2-, 6-, and 25-MV attenuation curves were evaluated to determine the energy spectra of these beams. The 2-MV data indicate that the model can reliably reconstruct spectra in the low megavoltage range. Experimental limitations in acquiring the 6-MV transmission data demonstrate the sensitivity of the model to systematic experimental error. The 25-MV data result in a physically realistic approximation of the present spectrum.
A Temperature Sensor Based on a Polymer Optical Fiber Macro-Bend
Moraleda, Alberto Tapetado; García, Carmen Vázquez; Zaballa, Joseba Zubia; Arrue, Jon
2013-01-01
The design and development of a plastic optical fiber (POF) macrobend temperature sensor is presented. The sensor has a linear response versus temperature at a fixed bend radius, with a sensitivity of 1.92·10−3 (°C)−1. The sensor system used a dummy fiber-optic sensor for reference purposes having a resolution below 0.3 °C. A comprehensive experimental analysis was carried out to provide insight into the effect of different surrounding media on practical macro-bend POF sensor implementation. Experimental results are successfully compared with bend loss calculations. PMID:24077323
NASA Astrophysics Data System (ADS)
Kashfuddoja, Mohammad; Prasath, R. G. R.; Ramji, M.
2014-11-01
In this work, the experimental characterization of polymer-matrix and polymer based carbon fiber reinforced composite laminate by employing a whole field non-contact digital image correlation (DIC) technique is presented. The properties are evaluated based on full field data obtained from DIC measurements by performing a series of tests as per ASTM standards. The evaluated properties are compared with the results obtained from conventional testing and analytical models and they are found to closely match. Further, sensitivity of DIC parameters on material properties is investigated and their optimum value is identified. It is found that the subset size has more influence on material properties as compared to step size and their predicted optimum value for the case of both matrix and composite material is found consistent with each other. The aspect ratio of region of interest (ROI) chosen for correlation should be the same as that of camera resolution aspect ratio for better correlation. Also, an open cutout panel made of the same composite laminate is taken into consideration to demonstrate the sensitivity of DIC parameters on predicting complex strain field surrounding the hole. It is observed that the strain field surrounding the hole is much more sensitive to step size rather than subset size. Lower step size produced highly pixilated strain field, showing sensitivity of local strain at the expense of computational time in addition with random scattered noisy pattern whereas higher step size mitigates the noisy pattern at the expense of losing the details present in data and even alters the natural trend of strain field leading to erroneous maximum strain locations. The subset size variation mainly presents a smoothing effect, eliminating noise from strain field while maintaining the details in the data without altering their natural trend. However, the increase in subset size significantly reduces the strain data at hole edge due to discontinuity in correlation. Also, the DIC results are compared with FEA prediction to ascertain the suitable value of DIC parameters towards better accuracy.
Depth estimation of multi-layered impact damage in PMC using lateral thermography
NASA Astrophysics Data System (ADS)
Whitlow, Travis; Kramb, Victoria; Reibel, Rick; Dierken, Josiah
2018-04-01
Characterization of impact damage in polymer matrix composites (PMCs) continues to be a challenge due to the complex internal structure of the material. Nondestructive characterization approaches such as normal incident immersion ultrasound and flash thermography are sensitive to delamination damage, but do not provide information regarding damage obscured by the delaminations. Characterization of material state below a delamination requires a technique which is sensitive to in-plane damage modes such as matrix cracking and fiber breakage. Previous studies of the lateral heat flow through a composite laminate showed that the diffusion time was sensitive to the depth of the simulated damage zone. The current study will further evaluate the lateral diffusion model to provide sensitivity limits for the modeled flaw dimensions. Comparisons between the model simulations and experimental data obtained using a concentrated heat source and machined targets will also be presented.
NASA Astrophysics Data System (ADS)
Phan, Hoang-Phuong; Dinh, Toan; Kozeki, Takahiro; Nguyen, Tuan-Khoa; Qamar, Afzaal; Namazu, Takahiro; Nguyen, Nam-Trung; Dao, Dzung Viet
2016-09-01
This paper presents an innovative nano strain-amplifier employed to significantly enhance the sensitivity of piezoresistive strain sensors. Inspired from the dogbone structure, the nano strain-amplifier consists of a nano thin frame released from the substrate, where nanowires were formed at the centre of the frame. Analytical and numerical results indicated that a nano strain-amplifier significantly increases the strain induced into a free standing nanowire, resulting in a large change in their electrical conductance. The proposed structure was demonstrated in p-type cubic silicon carbide nanowires fabricated using a top down process. The experimental data showed that the nano strain-amplifier can enhance the sensitivity of SiC strain sensors at least 5.4 times larger than that of the conventional structures. This result indicates the potential of the proposed strain-amplifier for ultra-sensitive mechanical sensing applications.
Real-Time and In-Flow Sensing Using a High Sensitivity Porous Silicon Microcavity-Based Sensor.
Caroselli, Raffaele; Martín Sánchez, David; Ponce Alcántara, Salvador; Prats Quilez, Francisco; Torrijos Morán, Luis; García-Rupérez, Jaime
2017-12-05
Porous silicon seems to be an appropriate material platform for the development of high-sensitivity and low-cost optical sensors, as their porous nature increases the interaction with the target substances, and their fabrication process is very simple and inexpensive. In this paper, we present the experimental development of a porous silicon microcavity sensor and its use for real-time in-flow sensing application. A high-sensitivity configuration was designed and then fabricated, by electrochemically etching a silicon wafer. Refractive index sensing experiments were realized by flowing several dilutions with decreasing refractive indices, and measuring the spectral shift in real-time. The porous silicon microcavity sensor showed a very linear response over a wide refractive index range, with a sensitivity around 1000 nm/refractive index unit (RIU), which allowed us to directly detect refractive index variations in the 10 -7 RIU range.
Sensitivity of optical mass sensor enhanced by optomechanical coupling
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Yong, E-mail: hey@cczu.edu.cn
Optical mass sensors based on cavity optomechanics employ radiation pressure force to drive mechanical resonator whose mechanical susceptibility can be described by nonlinear optical transmission spectrum. In this paper, we present an optical mass sensor based on a two-cavity optomechanical system where the mechanical damping rate can be decreased by adjusting a pump power so that the mass sensitivity which depends on the mechanical quality factor has been enhanced greatly. Compared with that of an optical mass sensor based on single-cavity optomechanics, the mass sensitivity of the optical mass sensor is improved by three orders of magnitude. This is anmore » approach to enhance the mass sensitivity by means of optomechanical coupling, which is suitable for all mass sensor based on cavity optomechanics. Finally, we illustrate the accurate measurement for the mass of a few chromosomes, which can be achieved based on the current experimental conditions.« less
Analysis of multimode fiber bundles for endoscopic spectral-domain optical coherence tomography
Risi, Matthew D.; Makhlouf, Houssine; Rouse, Andrew R.; Gmitro, Arthur F.
2016-01-01
A theoretical analysis of the use of a fiber bundle in spectral-domain optical coherence tomography (OCT) systems is presented. The fiber bundle enables a flexible endoscopic design and provides fast, parallelized acquisition of the OCT data. However, the multimode characteristic of the fibers in the fiber bundle affects the depth sensitivity of the imaging system. A description of light interference in a multimode fiber is presented along with numerical simulations and experimental studies to illustrate the theoretical analysis. PMID:25967012
The Construction of the UCSC Econo-Box: An Inexpensive Yet Effective Glove Box
NASA Astrophysics Data System (ADS)
Suri, Jeff T.
2001-11-01
An inexpensive, acrylic dry (glove) box has been fabricated and utilized in the handling of water- and air-sensitive materials. Working drawings are provided and a complete layout of material costs is presented. The box was experimentally determined to be moisture-free for three days and critically oxygen-free for 20 minutes under an inert gas atmosphere.
ERIC Educational Resources Information Center
Gogate, Lakshmi; Maganti, Madhavilatha; Perenyi, Agnes
2014-01-01
Purpose: This experimental study examined term infants (n = 34) and low-risk near-term preterm infants (gestational age 32-36 weeks) at 2 months chronological age (n = 34) and corrected age (n = 16). The study investigated whether the preterm infants presented with a delay in their sensitivity to synchronous syllable-object pairings when compared…
Experimental Work in Biology: Book 1, Food Tests; Book 2, Enzymes; Book 3, Soil.
ERIC Educational Resources Information Center
Mackean, D. G.
Laboratory experiments are presented in these first three manuals of a six-volume series for use at the 12- to 16-year-old, or British CSE, level. On the subject of food tests, 17 exercises are prepared in connection with Biuret reactions, starch and emulsion tests, Millon's and Benedict's reagents, reagent sensitivity, and calorific values and…
Detection of soy proteins in processed foods: literature overview and new experimental work.
Koppelman, Stef J; Lakemond, Catriona M M; Vlooswijk, Riek; Hefle, Susan L
2004-01-01
Several tests for the detection of soy proteins in foods have been described in the literature, and some are commercially available. This article gives an overview of these methods and discusses the advantages and disadvantages of each individual method. Based on the conclusions of this inventory, an experimental approach was designed to improve the sensitivity of measuring soy protein in processed foods. The aimed sensitivity is 10 ppm (10 microg soy protein in 1 g solid sample), which is over 100-fold lower than presently available tests. The aimed sensitivity is this low because levels of food allergens at 10 ppm and above may provoke reactions in food allergic persons. Native soybean meal, soy protein isolate, soy protein concentrate, and textured soy flakes were used as test materials. Several extraction procedures were compared and a new method using high pH was selected. Polyclonal antibodies were raised in rabbits and goats, and immunopurified antibodies were used in sandwich and inhibition enzyme-linked immunosorbent assay (ELISA). Extraction at pH 12 resulted in good yields for all tested samples, both quantitatively (Bradford) and qualitatively by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Immunopurified rabbit antibodies against this extract used in a competition ELISA format resulted in a sensitive test with a detection limit of 0.02 microg/mL, corresponding to 0.4 microg/g (0.4 ppm) in food samples. Cross-reactivity with some main food ingredients was measured and appeared to be negative in all cases. The presently developed test is applicable for soy ingredients and soy-containing foods that are processed in different ways. The limit of quantitation is 1 ppm, which is an enormous improvement over earlier described methods.
NASA Astrophysics Data System (ADS)
Ho, Teck Seng; Charles, Christine; Boswell, Roderick W.
2016-12-01
This paper presents computational fluid dynamics simulations of the cold gas operation of Pocket Rocket and Mini Pocket Rocket radiofrequency electrothermal microthrusters, replicating experiments performed in both sub-Torr and vacuum environments. This work takes advantage of flow velocity choking to circumvent the invalidity of modelling vacuum regions within a CFD simulation, while still preserving the accuracy of the desired results in the internal regions of the microthrusters. Simulated results of the plenum stagnation pressure is in precise agreement with experimental measurements when slip boundary conditions with the correct tangential momentum accommodation coefficients for each gas are used. Thrust and specific impulse is calculated by integrating the flow profiles at the exit of the microthrusters, and are in good agreement with experimental pendulum thrust balance measurements and theoretical expectations. For low thrust conditions where experimental instruments are not sufficiently sensitive, these cold gas simulations provide additional data points against which experimental results can be verified and extrapolated. The cold gas simulations presented in this paper will be used as a benchmark to compare with future plasma simulations of the Pocket Rocket microthruster.
Experimental characterization of the perceptron laser rangefinder
NASA Technical Reports Server (NTRS)
Kweon, I. S.; Hoffman, Regis; Krotkov, Eric
1991-01-01
In this report, we characterize experimentally a scanning laser rangefinder that employs active sensing to acquire three-dimensional images. We present experimental techniques applicable to a wide variety of laser scanners, and document the results of applying them to a device manufactured by Perceptron. Nominally, the sensor acquires data over a 60 deg x 60 deg field of view in 256 x 256 pixel images at 2 Hz. It digitizes both range and reflectance pixels to 12 bits, providing a maximum range of 40 m and a depth resolution of 1 cm. We present methods and results from experiments to measure geometric parameters including the field of view, angular scanning increments, and minimum sensing distance. We characterize qualitatively problems caused by implementation flaws, including internal reflections and range drift over time, and problems caused by inherent limitations of the rangefinding technology, including sensitivity to ambient light and surface material. We characterize statistically the precision and accuracy of the range measurements. We conclude that the performance of the Perceptron scanner does not compare favorably with the nominal performance, that scanner modifications are required, and that further experimentation must be conducted.
Herbert, Matthew S.; Goodin, Burel R.; Pero, Samuel T.; Schmidt, Jessica K.; Sotolongo, Adriana; Bulls, Hailey W.; Glover, Toni L.; King, Christopher D.; Sibille, Kimberly T.; Cruz-Almeida, Yenisel; Staud, Roland; Fessler, Barri J.; Bradley, Laurence A.; Fillingim, Roger B.
2014-01-01
Background Pain hypervigilance is an important aspect of the fear-avoidance model of pain that may help explain individual differences in pain sensitivity among persons with knee osteoarthritis (OA). Purpose The purpose of this study was to examine the contribution of pain hypervigilance to clinical pain severity and experimental pain sensitivity in persons with symptomatic knee OA. Methods We analyzed cross-sectional data from 168 adults with symptomatic knee OA. Quantitative sensory testing was used to measure sensitivity to heat pain, pressure pain, and cold pain, as well as temporal summation of heat pain, a marker of central sensitization. Results Pain hypervigilance was associated with greater clinical pain severity, as well as greater pressure pain. Pain hypervigilance was also a significant predictor of temporal summation of heat pain. Conclusions Pain hypervigilance may be an important contributor to pain reports and experimental pain sensitivity among persons with knee OA. PMID:24352850
Frequency dependence of trapped flux sensitivity in SRF cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Checchin, M.; Martinello, M.; Grassellino, A.
In this paper, we present the frequency dependence of the vortex surface resistance of bulk niobium accelerating cavities as a function of different state-of-the-art surface treatments. Higher flux surface resistance per amount of trapped magnetic field - sensitivity - is observed for higher frequencies, in agreement with our theoretical model. Higher sensitivity is observed for N-doped cavities, which possess an intermediate value of electron mean-free-path, compared to 120° C and EP/BCP cavities. Experimental results from our study showed that the sensitivity has a non-monotonic trend as a function of the mean-free-path, including at frequencies other than 1.3 GHz, and thatmore » the vortex response to the rf field can be tuned from the pinning regime to flux-flow regime by manipulating the frequency and/or the mean-free-path of the resonator, as reported in our previous studies. The frequency dependence of the trapped flux sensitivity to the amplitude of the accelerating gradient is also highlighted.« less
Frequency dependence of trapped flux sensitivity in SRF cavities
Checchin, M.; Martinello, M.; Grassellino, A.; ...
2018-02-13
In this paper, we present the frequency dependence of the vortex surface resistance of bulk niobium accelerating cavities as a function of different state-of-the-art surface treatments. Higher flux surface resistance per amount of trapped magnetic field - sensitivity - is observed for higher frequencies, in agreement with our theoretical model. Higher sensitivity is observed for N-doped cavities, which possess an intermediate value of electron mean-free-path, compared to 120° C and EP/BCP cavities. Experimental results from our study showed that the sensitivity has a non-monotonic trend as a function of the mean-free-path, including at frequencies other than 1.3 GHz, and thatmore » the vortex response to the rf field can be tuned from the pinning regime to flux-flow regime by manipulating the frequency and/or the mean-free-path of the resonator, as reported in our previous studies. The frequency dependence of the trapped flux sensitivity to the amplitude of the accelerating gradient is also highlighted.« less
Computational study of single-expansion-ramp nozzles with external burning
NASA Astrophysics Data System (ADS)
Yungster, Shaye; Trefny, Charles J.
1992-04-01
A computational investigation of the effects of external burning on the performance of single expansion ramp nozzles (SERN) operating at transonic speeds is presented. The study focuses on the effects of external heat addition and introduces a simplified injection and mixing model based on a control volume analysis. This simplified model permits parametric and scaling studies that would have been impossible to conduct with a detailed CFD analysis. The CFD model is validated by comparing the computed pressure distribution and thrust forces, for several nozzle configurations, with experimental data. Specific impulse calculations are also presented which indicate that external burning performance can be superior to other methods of thrust augmentation at transonic speeds. The effects of injection fuel pressure and nozzle pressure ratio on the performance of SERN nozzles with external burning are described. The results show trends similar to those reported in the experimental study, and provide additional information that complements the experimental data, improving our understanding of external burning flowfields. A study of the effect of scale is also presented. The results indicate that combustion kinetics do not make the flowfield sensitive to scale.
Computational study of single-expansion-ramp nozzles with external burning
NASA Technical Reports Server (NTRS)
Yungster, Shaye; Trefny, Charles J.
1992-01-01
A computational investigation of the effects of external burning on the performance of single expansion ramp nozzles (SERN) operating at transonic speeds is presented. The study focuses on the effects of external heat addition and introduces a simplified injection and mixing model based on a control volume analysis. This simplified model permits parametric and scaling studies that would have been impossible to conduct with a detailed CFD analysis. The CFD model is validated by comparing the computed pressure distribution and thrust forces, for several nozzle configurations, with experimental data. Specific impulse calculations are also presented which indicate that external burning performance can be superior to other methods of thrust augmentation at transonic speeds. The effects of injection fuel pressure and nozzle pressure ratio on the performance of SERN nozzles with external burning are described. The results show trends similar to those reported in the experimental study, and provide additional information that complements the experimental data, improving our understanding of external burning flowfields. A study of the effect of scale is also presented. The results indicate that combustion kinetics do not make the flowfield sensitive to scale.
Higher order acoustoelastic Lamb wave propagation in stressed plates.
Pei, Ning; Bond, Leonard J
2016-11-01
Modeling and experiments are used to investigate Lamb wave propagation in the direction perpendicular to an applied stress. Sensitivity, in terms of changes in velocity, for both symmetrical and anti-symmetrical modes was determined. Codes were developed based on analytical expressions for waves in loaded plates and they were used to give wave dispersion curves. The experimental system used a pair of compression wave transducers on variable angle wedges, with set separation, and variable frequency tone burst excitation, on an aluminum plate 0.16 cm thick with uniaxial applied loads. The loads, which were up to 600 με, were measured using strain gages. Model results and experimental data are in good agreement. It was found that the change in Lamb wave velocity, due to the acoustoelastic effect, for the S 1 mode exhibits about ten times more sensitive, in terms of velocity change, than the traditional bulk wave measurements, and those performed using the fundamental Lamb modes. The data presented demonstrate the potential for the use of higher order Lamb modes for online industrial stress measurement in plate, and that the higher sensitivity seen offers potential for improved measurement systems.
Identification of the optimal spectral region for plasmonic and nanoplasmonic sensing.
Otte, Marinus A; Sepúlveda, Borja; Ni, Weihai; Juste, Jorge Pérez; Liz-Marzán, Luis M; Lechuga, Laura M
2010-01-26
We present a theoretical and experimental study involving the sensing characteristics of wavelength-interrogated plasmonic sensors based on surface plasmon polaritons (SPP) in planar gold films and on localized surface plasmon resonances (LSPR) of single gold nanorods. The tunability of both sensing platforms allowed us to analyze their bulk and surface sensing characteristics as a function of the plasmon resonance position. We demonstrate that a general figure of merit (FOM), which is equivalent in wavelength and energy scales, can be employed to mutually compare both sensing schemes. Most interestingly, this FOM has revealed a spectral region for which the surface sensitivity performance of both sensor types is optimized, which we attribute to the intrinsic dielectric properties of plasmonic materials. Additionally, in good agreement with theoretical predictions, we experimentally demonstrate that, although the SPP sensor offers a much better bulk sensitivity, the LSPR sensor shows an approximately 15% better performance for surface sensitivity measurements when its FOM is optimized. However, optimization of the substrate refractive index and the accessibility of the relevant molecules to the nanoparticles can lead to a total 3-fold improvement of the FOM in LSPR sensors.
NASA Astrophysics Data System (ADS)
Lu, Qianbo; Bai, Jian; Wang, Kaiwei; Lou, Shuqi; Jiao, Xufen; Han, Dandan; Yang, Guoguang
2016-08-01
The ultrahigh static displacement-acceleration sensitivity of a mechanical sensing chip is essential primarily for an ultrasensitive accelerometer. In this paper, an optimal design to implement to a single-axis MOEMS accelerometer consisting of a grating interferometry cavity and a micromachined sensing chip is presented. The micromachined sensing chip is composed of a proof mass along with its mechanical cantilever suspension and substrate. The dimensional parameters of the sensing chip, including the length, width, thickness and position of the cantilevers are evaluated and optimized both analytically and by finite-element-method (FEM) simulation to yield an unprecedented acceleration-displacement sensitivity. Compared with one of the most sensitive single-axis MOEMS accelerometers reported in the literature, the optimal mechanical design can yield a profound sensitivity improvement with an equal footprint area, specifically, 200% improvement in displacement-acceleration sensitivity with moderate resonant frequency and dynamic range. The modified design was microfabricated, packaged with the grating interferometry cavity and tested. The experimental results demonstrate that the MOEMS accelerometer with modified design can achieve the acceleration-displacement sensitivity of about 150μm/g and acceleration sensitivity of greater than 1500V/g, which validates the effectiveness of the optimal design.
Mehl, S.; Hill, M.C.
2001-01-01
Five common numerical techniques for solving the advection-dispersion equation (finite difference, predictor corrector, total variation diminishing, method of characteristics, and modified method of characteristics) were tested using simulations of a controlled conservative tracer-test experiment through a heterogeneous, two-dimensional sand tank. The experimental facility was constructed using discrete, randomly distributed, homogeneous blocks of five sand types. This experimental model provides an opportunity to compare the solution techniques: the heterogeneous hydraulic-conductivity distribution of known structure can be accurately represented by a numerical model, and detailed measurements can be compared with simulated concentrations and total flow through the tank. The present work uses this opportunity to investigate how three common types of results - simulated breakthrough curves, sensitivity analysis, and calibrated parameter values - change in this heterogeneous situation given the different methods of simulating solute transport. The breakthrough curves show that simulated peak concentrations, even at very fine grid spacings, varied between the techniques because of different amounts of numerical dispersion. Sensitivity-analysis results revealed: (1) a high correlation between hydraulic conductivity and porosity given the concentration and flow observations used, so that both could not be estimated; and (2) that the breakthrough curve data did not provide enough information to estimate individual values of dispersivity for the five sands. This study demonstrates that the choice of assigned dispersivity and the amount of numerical dispersion present in the solution technique influence estimated hydraulic conductivity values to a surprising degree.
NASA Astrophysics Data System (ADS)
Yu, Zhongliang; Zhao, Yulong; Sun, Lu; Tian, Bian; Jiang, Zhuangde
2013-01-01
The paper presents a piezoresistive absolute micro pressure sensor, which is of great benefits for altitude location. In this investigation, the design, fabrication, and test of the sensor are involved. By analyzing the stress distribution of sensitive elements using finite element method, a novel structure through the introduction of sensitive beams into traditional bossed diaphragm is built up. The proposed configuration presents its advantages in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the equations about the sensor. Nonlinear optimization by MATLAB is carried out to determine the structure dimensions. The output signals in both static and dynamic environments are evaluated. Silicon bulk micromachining technology is utilized to fabricate the sensor prototype, and the fabrication process is discussed. Experimental results demonstrate the sensor features a high sensitivity of 11.098 μV/V/Pa in the operating range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure to promise its survival under atmosphere. Due to the excellent performance above, the sensor can be applied in measuring the absolute micro pressure lower than 500 Pa.
High sensitivity gas sensor based on high-Q suspended polymer photonic crystal nanocavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clevenson, Hannah, E-mail: hannahac@mit.edu; Desjardins, Pierre; Gan, Xuetao
2014-06-16
We present high-sensitivity, multi-use optical gas sensors based on a one-dimensional photonic crystal cavity. These devices are implemented in versatile, flexible polymer materials which swell when in contact with a target gas, causing a measurable cavity length change. This change causes a shift in the cavity resonance, allowing precision measurements of gas concentration. We demonstrate suspended polymer nanocavity sensors and the recovery of sensors after the removal of stimulant gas from the system. With a measured quality factor exceeding 10{sup 4}, we show measurements of gas concentration as low as 600 parts per million (ppm) and an experimental sensitivity ofmore » 10 ppm; furthermore, we predict detection levels in the parts-per-billion range for a variety of gases.« less
Suppression of extraneous thermal noise in cavity optomechanics.
Zhao, Yi; Wilson, Dalziel J; Ni, K-K; Kimble, H J
2012-02-13
Extraneous thermal motion can limit displacement sensitivity and radiation pressure effects, such as optical cooling, in a cavity-optomechanical system. Here we present an active noise suppression scheme and its experimental implementation. The main challenge is to selectively sense and suppress extraneous thermal noise without affecting motion of the oscillator. Our solution is to monitor two modes of the optical cavity, each with different sensitivity to the oscillator's motion but similar sensitivity to the extraneous thermal motion. This information is used to imprint "anti-noise" onto the frequency of the incident laser field. In our system, based on a nano-mechanical membrane coupled to a Fabry-Pérot cavity, simulation and experiment demonstrate that extraneous thermal noise can be selectively suppressed and that the associated limit on optical cooling can be reduced.
Miniature FBG-based fluidic flowmeter to measure hot oil and water
NASA Astrophysics Data System (ADS)
Liu, Zhengyong; Htein, Lin; Cheng, Lun-Kai; Martina, Quincy; Jansen, Rob; Tam, Hwa-Yaw
2017-04-01
In this paper, we present a miniature fluidic flowmeter based on a packaged FBG and laser-heated fibers. The flow rates of water and hydraulic oil were measured by utilizing the proposed flowmeter. The measured results exhibited good sensitivity of 0.339 nm/(m/s) for water and 0.578 nm/(m/s) for oil flow. Experimental results showed that the sensitivity of the fluidic flow sensor is depending on the heat capacity of the fluids, where the fluid with higher heat capacity has higher sensitivity and lower detection limit at the same measurement condition. The real-time flow rates measured by the proposed sensor and a commercial flowmeter installed in the test rig were also compared, demonstrating good agreement with correlation coefficient of 0.9974.
NASA Astrophysics Data System (ADS)
Ponomarev, Yu. N.; Solodov, A. A.; Solodov, A. M.; Petrova, T. M.; Naumenko, O. V.
2016-07-01
A description of the spectroscopic complex at V.E. Zuev Institute of Atmospheric Optics, SB RAS, operating in a wide spectral range with high threshold sensitivity to the absorption coefficient is presented. Measurements of weak lines and nonselective spectra of CO2 and H2O were performed based on the built setup. As new application of this setup, positions and intensities of 152 weak lines of H2O were measured between 2400 and 2560 cm-1 with threshold sensitivity of 8.6×10-10 cm-1, and compared with available calculated and experimental data. Essential deviations between the new intensity measurements and calculated data accepted in HITRAN 2012 and GEISA 2015 forthcoming release are found.
Colyar, Jessica M; Eggett, Dennis L; Steele, Frost M; Dunn, Michael L; Ogden, Lynn V
2009-09-01
The relative sensitivity of side-by-side and sequential monadic consumer liking protocols was compared. In the side-by-side evaluation, all samples were presented at once and evaluated together 1 characteristic at a time. In the sequential monadic evaluation, 1 sample was presented and evaluated on all characteristics, then returned before panelists received and evaluated another sample. Evaluations were conducted on orange juice, frankfurters, canned chili, potato chips, and applesauce. Five commercial brands, having a broad quality range, were selected as samples for each product category to assure a wide array of consumer liking scores. Without their knowledge, panelists rated the same 5 retail brands by 1 protocol and then 3 wk later by the other protocol. For 3 of the products, both protocols yielded the same order of overall liking. Slight differences in order of overall liking for the other 2 products were not significant. Of the 50 pairwise overall liking comparisons, 44 were in agreement. The different results obtained by the 2 protocols in order of liking and significance of paired comparisons were due to the experimental variation and differences in sensitivity. Hedonic liking scores were subjected to statistical power analyses and used to calculate minimum number of panelists required to achieve varying degrees of sensitivity when using side-by-side and sequential monadic protocols. In most cases, the side-by-side protocol was more sensitive, thus providing the same information with fewer panelists. Side-by-side protocol was less sensitive in cases where sensory fatigue was a factor.
Sensitizing Effects of Pretreatment Measures on Cancer Chemotherapy Nausea and Vomiting.
ERIC Educational Resources Information Center
Gard, Diane; And Others
1988-01-01
Explored sensitizing effects of pretreatment assessment on posttreatment chemotherapy nausea and vomiting and interactive effects of personal dispositions for information seeking. Oncology patients rated side effects experienced previously (experimental condition), or parking conditions (control). Posttreatment, nausea of experimentals was…
Caselli, Federica; Bisegna, Paolo
2017-10-01
The performance of a novel microfluidic impedance cytometer (MIC) with coplanar configuration is investigated in silico. The main feature of the device is the ability to provide accurate particle-sizing despite the well-known measurement sensitivity to particle trajectory. The working principle of the device is presented and validated by means of an original virtual laboratory providing close-to-experimental synthetic data streams. It is shown that a metric correlating with particle trajectory can be extracted from the signal traces and used to compensate the trajectory-induced error in the estimated particle size, thus reaching high-accuracy. An analysis of relevant parameters of the experimental setup is also presented. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Fiber optic micro sensor for the measurement of tendon forces
2012-01-01
A fiber optic sensor developed for the measurement of tendon forces was designed, numerically modeled, fabricated, and experimentally evaluated. The sensor incorporated fiber Bragg gratings and micro-fabricated stainless steel housings. A fiber Bragg grating is an optical device that is spectrally sensitive to axial strain. Stainless steel housings were designed to convert radial forces applied to the housing into axial forces that could be sensed by the fiber Bragg grating. The metal housings were fabricated by several methods including laser micromachining, swaging, and hydroforming. Designs are presented that allow for simultaneous temperature and force measurements as well as for simultaneous resolution of multi-axis forces. The sensor was experimentally evaluated by hydrostatic loading and in vitro testing. A commercial hydraulic burst tester was used to provide uniform pressures on the sensor in order to establish the linearity, repeatability, and accuracy characteristics of the sensor. The in vitro experiments were performed in excised tendon and in a dynamic gait simulator to simulate biological conditions. In both experimental conditions, the sensor was found to be a sensitive and reliable method for acquiring minimally invasive measurements of soft tissue forces. Our results suggest that this sensor will prove useful in a variety of biomechanical measurements. PMID:23033868
Computerized optimization of radioimmunoassays for hCG and estradiol: an experimental evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanagishita, M.; Rodbard, D.
1978-07-15
The mathematical and statistical theory of radioimmunoassays (RIAs) has been used to develop a series of computer programs to optimize sensitivity or precision at any desired dose level for either equilibrium or nonequilibrium assays. These computer programs provide for the calculation of the equilibrium constants of association and binding capacities for antisera (parameters of Scatchard plots), the association and dissociation rate constants, and prediction of optimum concentration of labeled ligand and antibody and optimum incubation times for the assay. This paper presents an experimental evaluation of the use of these computer programs applied to RIAs for human chorionic gonadotropin (hCG)more » and estradiol. The experimental results are in reasonable semiquantitative agreement with the predictions of the computer simulations (usually within a factor of two) and thus partially validate the use of computer techniques to optimize RIAs that are reasonably well behaved, as in the case of the hCG and estradiol RIAs. Further, these programs can provide insights into the nature of the RIA system, e.g., the general nature of the sensitivity and precision surfaces. This facilitates empirical optimization of conditions.« less
Observability Analysis of a MEMS INS/GPS Integration System with Gyroscope G-Sensitivity Errors
Fan, Chen; Hu, Xiaoping; He, Xiaofeng; Tang, Kanghua; Luo, Bing
2014-01-01
Gyroscopes based on micro-electromechanical system (MEMS) technology suffer in high-dynamic applications due to obvious g-sensitivity errors. These errors can induce large biases in the gyroscope, which can directly affect the accuracy of attitude estimation in the integration of the inertial navigation system (INS) and the Global Positioning System (GPS). The observability determines the existence of solutions for compensating them. In this paper, we investigate the observability of the INS/GPS system with consideration of the g-sensitivity errors. In terms of two types of g-sensitivity coefficients matrix, we add them as estimated states to the Kalman filter and analyze the observability of three or nine elements of the coefficient matrix respectively. A global observable condition of the system is presented and validated. Experimental results indicate that all the estimated states, which include position, velocity, attitude, gyro and accelerometer bias, and g-sensitivity coefficients, could be made observable by maneuvering based on the conditions. Compared with the integration system without compensation for the g-sensitivity errors, the attitude accuracy is raised obviously. PMID:25171122
Observability analysis of a MEMS INS/GPS integration system with gyroscope G-sensitivity errors.
Fan, Chen; Hu, Xiaoping; He, Xiaofeng; Tang, Kanghua; Luo, Bing
2014-08-28
Gyroscopes based on micro-electromechanical system (MEMS) technology suffer in high-dynamic applications due to obvious g-sensitivity errors. These errors can induce large biases in the gyroscope, which can directly affect the accuracy of attitude estimation in the integration of the inertial navigation system (INS) and the Global Positioning System (GPS). The observability determines the existence of solutions for compensating them. In this paper, we investigate the observability of the INS/GPS system with consideration of the g-sensitivity errors. In terms of two types of g-sensitivity coefficients matrix, we add them as estimated states to the Kalman filter and analyze the observability of three or nine elements of the coefficient matrix respectively. A global observable condition of the system is presented and validated. Experimental results indicate that all the estimated states, which include position, velocity, attitude, gyro and accelerometer bias, and g-sensitivity coefficients, could be made observable by maneuvering based on the conditions. Compared with the integration system without compensation for the g-sensitivity errors, the attitude accuracy is raised obviously.
Experimental Searches for Exotic Short-Range Forces Using Mechanical Oscillators
NASA Astrophysics Data System (ADS)
Weisman, Evan
Experimental searches for forces beyond gravity and electromagnetism at short range have attracted a great deal of attention over the last decade. In this thesis I describe the test mass development for two new experiments searching for forces below 1 mm. Both modify a previous experiment that used 1 kHz mechanical oscillators as test masses with a stiff conducting shield between them to suppress backgrounds, a promising technique for probing exceptionally small distances at the limit of instrumental thermal noise. To further reduce thermal noise, one experiment will use plated silicon test masses at cryogenic temperatures. The other experiment, which searches for spin-dependent interactions, will apply the spin-polarizable material Dy3Fe5O 12 to the test mass surfaces. This material exhibits orbital compensation of the magnetism associated with its intrinsic electron spin, minimizing magnetic backgrounds. Several plated silicon test mass prototypes were fabricated using photolithography (useful in both experiments), and spin-dependent materials were synthesized with a simple chemical recipe. Both silicon and spin-dependent test masses demonstrate the mechanical and magnetic properties necessary for sensitive experiments. I also describe sensitivity calculations of another proposed spin-dependent experiment, based on a modified search for the electron electric dipole moment, which show unprecedented sensitivity to exotic monopole-dipole forces. Inspired by a finite element model, a study attempting to maximize detector quality factor versus geometry is also presented, with experimental results so far not explained by the model.
A comparison of the in vitro cytotoxicity of conventional and resin modified glass ionomer cements
Selimović-Dragaš, Mediha; Huseinbegović, Amina; Kobašlija, Sedin; Hatibović-Kofman, Šahza
2012-01-01
To evaluate cytotoxicity of experimental conventional and resin modified glass-ionomer cements on UMR-106 osteoblast cell cultures and cell cultures of NIH3T3 mouse fibroblasts specimens were prepared for every experimental material and divided into: group 1. Conventional glass-ionomer cements: GC Fuji IX GP Fast, GC Fuji Triage and Ketac Silver; group 2. Resin modified glass-ionomer cements: GC Fuji II LC, GC Fuji Plus and Vitrebond; group 3. Positive control was presented by specimens of composite Vit-l-ecence® and negative control-group 4. was presented by α-minimum essential medium for UMR-106 – osteoblast-like cells and Dulbecco’s Modified Eagle’s Medium for NIH3T3 mouse fibroblast cells. Both cell cultures were exposed to 10% of eluate of each single specimen of each experimental material. Experimental dishes were incubated for 24 h. Cell metabolism was evaluated using methyltetrazolium assay. Kruskal-Wallis test and Tukey-Kramer post hoc test for the materials evaluated on NIH3T3 mouse fibroblast cells, as well as UMR-106 osteoblast-like cells showed significantly more cytotoxicity of RMGICs, predominantly Vitrebond to both GICs and composite-Vit-l-ecence®. The lowest influence on cell’s metabolism on UMR-106 osteoblas-like cells was shown by Ketac Silver and the lowest influence on cell’s metabolism on NIH3T3 mouse fibroblast cells was shown by Fuji IX GP Fast. Statistical evaluation of sensitivity of cell lines UMR-106 osteoblast-like cells and NIH3T3 mouse fibroblast cells, using Mann-Whitney test, showed that NIH3T3 mouse fibroblast cells were more sensitive for the evaluation of cytotoxicity of dental materials. PMID:23198945
Turbulence Model Sensitivity and Scour Gap Effect of Unsteady Flow around Pipe: A CFD Study
Ali, Abbod; Sharma, R. K.; Ganesan, P.
2014-01-01
A numerical investigation of incompressible and transient flow around circular pipe has been carried out at different five gap phases. Flow equations such as Navier-Stokes and continuity equations have been solved using finite volume method. Unsteady horizontal velocity and kinetic energy square root profiles are plotted using different turbulence models and their sensitivity is checked against published experimental results. Flow parameters such as horizontal velocity under pipe, pressure coefficient, wall shear stress, drag coefficient, and lift coefficient are studied and presented graphically to investigate the flow behavior around an immovable pipe and scoured bed. PMID:25136666
CFD and Aeroelastic Analysis of the MEXICO Wind Turbine
NASA Astrophysics Data System (ADS)
Carrión, M.; Woodgate, M.; Steijl, R.; Barakos, G.; Gómez-Iradi, S.; Munduate, X.
2014-12-01
This paper presents an aerodynamic and aeroelastic analysis of the MEXICO wind turbine, using the compressible HMB solver of Liverpool. The aeroelasticity of the blade, as well as the effect of a low-Mach scheme were studied for the zero-yaw 15m/s wind case and steady- state computations. The wake developed behind the rotor was also extracted and compared with the experimental data, using the compressible solver and a low-Mach scheme. It was found that the loads were not sensitive to the Mach number effects, although the low-Mach scheme improved the wake predictions. The sensitivity of the results to the blade structural properties was also highlighted.
NASA Astrophysics Data System (ADS)
Melgaard, Seth D.; Seletskiy, Denis V.; Di Lieto, Alberto; Tonelli, Mauro; Sheik-Bahae, Mansoor
2012-03-01
Since recent demonstration of cryogenic optical refrigeration, a need for reliable characterization tools of cooling performance of different materials is in high demand. We present our experimental apparatus that allows for temperature and wavelength dependent characterization of the materials' cooling efficiency and is based on highly sensitive spectral differencing technique or two-band differential spectral metrology (2B-DSM). First characterization of a 5% w.t. ytterbium-doped YLF crystal showed quantitative agreement with the current laser cooling model, as well as measured a minimum achievable temperature (MAT) at 110 K. Other materials and ion concentrations are also investigated and reported here.
Chang, Ming-Hui; Huang, Han-Pang
2013-01-01
This paper presents a novel parasitic-insensitive switched-capacitor (PISC) sensing circuit design in order to obtain high sensitivity and ultra linearity and reduce the parasitic effect for the out-of-plane single-gimbaled decoupled CMOS-MEMS gyroscope (SGDG). According to the simulation results, the proposed PISC circuit has better sensitivity and high linearity in a wide dynamic range. Experimental results also show a better performance. In addition, the PISC circuit can use signal processing to cancel the offset and noise. Thus, this circuit is very suitable for gyroscope measurement. PMID:23493122
NASA Astrophysics Data System (ADS)
Han, Maeum; Keon Kim, Jae; Kong, Seong Ho; Kang, Shin-Won; Jung, Daewoong
2018-06-01
This paper reports a micro-electro-mechanical-system (MEMS)-based tilt sensor using air medium. Since the working mechanism of the sensor is the thermal convection in a sealed chamber, structural parameters that can affect thermal convection must be considered to optimize the performance of the sensor. This paper presents the experimental results that were conducted by optimizing several parameters such as the heater geometry, input power and cavity volume. We observed that an increase in the heating power and cavity volume can improve the sensitivity, and heater geometry plays important role in performance of the sensor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Gangadhar, E-mail: gdas@rrcat.gov.in; Tiwari, M. K.; Singh, A. K.
The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-raymore » fluorescence detection sensitivities.« less
Li, Jie; Guo, Hao; Liu, Jun; Tang, Jun; Ni, Haiqiao; Shi, Yunbo; Xue, Chenyang; Niu, Zhichuan; Zhang, Wendong; Li, Mifeng; Yu, Ying
2013-05-08
As a highly sensitive strain gauge element, GaAs-based resonant tunneling diode (RTD) has already been applied in microelectromechanical system (MEMS) sensors. Due to poor mechanical properties and high cost, GaAs-based material has been limited in applications as the substrate for MEMS. In this work, we present a method to fabricate the GaAs-based RTD on Si substrate. From the experimental results, it can be concluded that the piezoresistive coefficient achieved with this method reached 3.42 × 10-9 m2/N, which is about an order of magnitude higher than the Si-based semiconductor piezoresistors.
Questioning cochlear amplification
NASA Astrophysics Data System (ADS)
van der Heijden, Marcel; Versteegh, Corstiaen P. C.
2015-12-01
Thirty years ago it was hypothesized that motile processes inject mechanical energy into cochlear traveling waves. This mechanical amplification, alternatively described as negative damping, is invoked to explain both the sensitivity and the nonlinear compression of cochlear responses. There is a recent trend to present cochlear amplification as an established fact, even though the evidence is at most circumstantial and several thorny problems have remained unresolved. We analyze several of these issues, and present new basilar membrane recordings that allowed us to quantify cochlear energy flow. Specifically, we address the following questions: (1) Does auditory sensitivity require narrowband amplification? (2) Has the "RC problem" (lowpass filtering of outer hair cell receptor potential) been resolved? (3) Can OHC motility improve auditory sensitivity? (4) Is there a net power gain between neighboring locations on the basilar membrane? The analyses indicate that mechanical amplification in the cochlea is neither necessary nor useful, and that realizing it by known forms of motility would reduce sensitivity rather than enhance it. Finally, our experimental data show that the peaking of the traveling wave is realized by focusing the acoustic energy rather than amplifying it. (Abbreviations. BM: basilar membrane; CF: characteristic frequency; IHC: inner hair cell; ME: middle ear; MT; mechanotransducer; OHC: outer hair cell; SPL: sound pressure level.)
Loganathan, Muthukumaran; Bristow, Douglas A
2014-04-01
This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.
NASA Technical Reports Server (NTRS)
Elrod, D. A.; Childs, D. W.
1986-01-01
A brief review of current annular seal theory and a discussion of the predicted effect on stiffness of tapering the seal stator are presented. An outline of Nelson's analytical-computational method for determining rotordynamic coefficients for annular compressible-flow seals is included. Modifications to increase the maximum rotor speed of an existing air-seal test apparatus at Texas A&M University are described. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and normalized rotordynamic coefficients, are presented for four convergent-tapered, smooth-rotor, smooth-stator seals. A comparison of the test results shows that an inlet-to-exit clearance ratio of 1.5 to 2.0 provides the maximum direct stiffness, a clearance ratio of 2.5 provides the greatest stability, and a clearance ratio of 1.0 provides the least stability. The experimental results are compared to theoretical results from Nelson's analysis with good agreement. Test results for cross-coupled stiffness show less sensitivity of fluid prerotation than predicted.
Concrete Cracking Prediction Including the Filling Proportion of Strand Corrosion Products.
Wang, Lei; Dai, Lizhao; Zhang, Xuhui; Zhang, Jianren
2016-12-23
The filling of strand corrosion products during concrete crack propagation is investigated experimentally in the present paper. The effects of stirrups on the filling of corrosion products and concrete cracking are clarified. A prediction model of crack width is developed incorporating the filling proportion of corrosion products and the twisting shape of the strand. Experimental data on cracking angle, crack width, and corrosion loss obtained from accelerated corrosion tests of concrete beams are presented. The proposed model is verified by experimental data. Results show that the filling extent of corrosion products varies with crack propagation. The rust filling extent increases with the propagating crack until a critical width. Beyond the critical width, the rust-filling extent remains stable. Using stirrups can decrease the critical crack width. Stirrups can restrict crack propagation and reduce the rust filling. The tangent of the cracking angle increases with increasing corrosion loss. The prediction of corrosion-induced crack is sensitive to the rust-filling extent.
Concrete Cracking Prediction Including the Filling Proportion of Strand Corrosion Products
Wang, Lei; Dai, Lizhao; Zhang, Xuhui; Zhang, Jianren
2016-01-01
The filling of strand corrosion products during concrete crack propagation is investigated experimentally in the present paper. The effects of stirrups on the filling of corrosion products and concrete cracking are clarified. A prediction model of crack width is developed incorporating the filling proportion of corrosion products and the twisting shape of the strand. Experimental data on cracking angle, crack width, and corrosion loss obtained from accelerated corrosion tests of concrete beams are presented. The proposed model is verified by experimental data. Results show that the filling extent of corrosion products varies with crack propagation. The rust filling extent increases with the propagating crack until a critical width. Beyond the critical width, the rust-filling extent remains stable. Using stirrups can decrease the critical crack width. Stirrups can restrict crack propagation and reduce the rust filling. The tangent of the cracking angle increases with increasing corrosion loss. The prediction of corrosion-induced crack is sensitive to the rust-filling extent. PMID:28772367
Sensitivity Analysis of Multidisciplinary Rotorcraft Simulations
NASA Technical Reports Server (NTRS)
Wang, Li; Diskin, Boris; Biedron, Robert T.; Nielsen, Eric J.; Bauchau, Olivier A.
2017-01-01
A multidisciplinary sensitivity analysis of rotorcraft simulations involving tightly coupled high-fidelity computational fluid dynamics and comprehensive analysis solvers is presented and evaluated. An unstructured sensitivity-enabled Navier-Stokes solver, FUN3D, and a nonlinear flexible multibody dynamics solver, DYMORE, are coupled to predict the aerodynamic loads and structural responses of helicopter rotor blades. A discretely-consistent adjoint-based sensitivity analysis available in FUN3D provides sensitivities arising from unsteady turbulent flows and unstructured dynamic overset meshes, while a complex-variable approach is used to compute DYMORE structural sensitivities with respect to aerodynamic loads. The multidisciplinary sensitivity analysis is conducted through integrating the sensitivity components from each discipline of the coupled system. Numerical results verify accuracy of the FUN3D/DYMORE system by conducting simulations for a benchmark rotorcraft test model and comparing solutions with established analyses and experimental data. Complex-variable implementation of sensitivity analysis of DYMORE and the coupled FUN3D/DYMORE system is verified by comparing with real-valued analysis and sensitivities. Correctness of adjoint formulations for FUN3D/DYMORE interfaces is verified by comparing adjoint-based and complex-variable sensitivities. Finally, sensitivities of the lift and drag functions obtained by complex-variable FUN3D/DYMORE simulations are compared with sensitivities computed by the multidisciplinary sensitivity analysis, which couples adjoint-based flow and grid sensitivities of FUN3D and FUN3D/DYMORE interfaces with complex-variable sensitivities of DYMORE structural responses.
Temperature prediction of space flight experiments by computer thermal analysis
NASA Technical Reports Server (NTRS)
Birdsong, M. B.; Luttges, M. W.
1994-01-01
Life sciences experiments are especially sensitive to temperature. A small temperature difference between otherwise identical samples can cause various differences in biological reaction rates. Knowledge of experimental temperatures and temperature histories help to distinguish the effects of microgravity and temperature on spaceflight experiments compared to ground based studies, and allow appropriate controls and sensitivity tests. Up to the present time, the Orbiter (Space Shuttle) has not generally provided temperature measurement instrumentation inside ambient lockers located in the Mid-deck of the Orbiter, or inside similar facilities such as Spacehab and Spacelab, but many pieces of hardware do have temperature recording capability. Most of these temperatures, however, have only been roughly measured or estimated. Such reported experimental temperatures, while accurate within a range of several degrees Celsius, are of limited utility to biological researchers. The temperature controlled lockers used in spaceflight, such as Commerical-Refrigeration Incubation Modules (C-R/IMs), severely reduce the mass and volume available for test samples and do not necessarily provide uniform thermal environments. While these test carriers avoid some of the experimental temperature variations of the ambient lockers, the number of samples which can be accommodated in these temperature controlled units is limited. In the present work, improved models of thermal prediction and control were sought. Temperatures are predicted by thermal analysis software using empirical temperatures recorded during STS-57. These temperatures are compared to data recorded throughout the mission using Ambient Temperature Recorders (ATRs) located within several payload lockers. Additional test cases are undertaken using controlled ground experiments to more precisely determine the reliability of the thermal model. The approach presented should increase the utility of various spaceflight carriers in the support of biological and material science research and ground control studies done in preparation for flight.
Temperature prediction of space flight experiments by computer thermal analysis.
Birdsong, M B; Luttges, M W
1995-02-01
Life sciences experiments are especially sensitive to temperature. A small temperature difference between otherwise identical samples can cause various differences in biological reaction rates. Knowledge of experimental temperatures and temperature histories help to distinguish the effects of microgravity and temperature on spaceflight experiments compared to ground based studies, and allow appropriate controls and sensitivity tests. Up to the present time, the Orbiter (Space Shuttle) has not generally provided temperature measurement instrumentation inside ambient lockers located in the Mid-deck of the Orbiter, or inside similar facilities such as Spacehab and Spacelab, but many pieces of hardware do have temperature recording capability. Most of these temperatures, however, have only been roughly measured or estimated. Such reported experimental temperatures, while accurate within a range of several degrees Celsius, are of limited utility to biological researchers. The temperature controlled lockers used in spaceflight, such as Commercial-Refrigeration Incubation Modules (C-R/IMs), severely reduce the mass and volume available for test samples and do not necessarily provide uniform thermal environments. While these test carriers avoid some of the experimental temperature variations of the ambient lockers, the number of samples which can be accommodated in these temperature controlled units is limited. In the present work, improved models of thermal prediction and control were sought. Temperatures are predicted by thermal analysis software using empirical temperatures recorded during STS-57. These temperatures are compared to data recorded throughout the mission using Ambient Temperature Recorders (ATRs) located within several payload lockers. Additional test cases are undertaken using controlled ground experiments to more precisely determine the reliability of the thermal model. The approach presented should increase the utility of various spaceflight carriers in the support of biological and material science research and ground control studies done in preparation for flight.
The Starlite Project - Prototyping Real-Time Software.
1992-11-01
by ONR under contract ledge of transactions and a temporal data model. A N00014-91-J-l 102, by DOE, and by NOSC. multiversion data object is one...environment. Section 4 presents experimentations of priority-based synchronization algorithms and multiversion data objects using the prototyping environment...priority-based .yn- chronization algorithms and between a multiversion database and its corresponding single- version database, through the sensitivity
Thermal loading in the laser holography nondestructive testing of a composite structure
NASA Technical Reports Server (NTRS)
Liu, H. K.; Kurtz, R. L.
1975-01-01
A laser holographic interferometry method that has variable sensitivity to surface deformation was applied to the investigation of composite test samples under thermal loading. A successful attempt was made to detect debonds in a fiberglass-epoxy-ceramic plate. Experimental results are presented along with the mathematical analysis of the physical model of the thermal loading and current conduction in the composite material.
Artifacts Of Spectral Analysis Of Instrument Readings
NASA Technical Reports Server (NTRS)
Wise, James H.
1995-01-01
Report presents experimental and theoretical study of some of artifacts introduced by processing outputs of two nominally identical low-frequency-reading instruments; high-sensitivity servo-accelerometers mounted together and operating, in conjunction with signal-conditioning circuits, as seismometers. Processing involved analog-to-digital conversion with anti-aliasing filtering, followed by digital processing including frequency weighting and computation of different measures of power spectral density (PSD).
DSMC Simulations of Hypersonic Flows With Shock Interactions and Validation With Experiments
NASA Technical Reports Server (NTRS)
Moss, James N.; Bird, Graeme A.
2004-01-01
The capabilities of a relatively new direct simulation Monte Carlo (DSMC) code are examined for the problem of hypersonic laminar shock/shock and shock/boundary layer interactions, where boundary layer separation is an important feature of the flow. Flow about two model configurations is considered, where both configurations (a biconic and a hollow cylinder-flare) have recent published experimental measurements. The computations are made by using the DS2V code of Bird, a general two-dimensional/axisymmetric time accurate code that incorporates many of the advances in DSMC over the past decade. The current focus is on flows produced in ground-based facilities at Mach 12 and 16 test conditions with nitrogen as the test gas and the test models at zero incidence. Results presented highlight the sensitivity of the calculations to grid resolutions, sensitivity to physical modeling parameters, and comparison with experimental measurements. Information is provided concerning the flow structure and surface results for the extent of separation, heating, pressure, and skin friction.
DSMC Simulations of Hypersonic Flows With Shock Interactions and Validation With Experiments
NASA Technical Reports Server (NTRS)
Moss, James N.; Bird, Graeme A.
2004-01-01
The capabilities of a relatively new direct simulation Monte Carlo (DSMC) code are examined for the problem of hypersonic laminar shock/shock and shock/boundary layer interactions, where boundary layer separation is an important feature of the flow. Flow about two model configurations is considered, where both configurations (a biconic and a hollow cylinder-flare) have recent published experimental measurements. The computations are made by using the DS2V code of Bird, a general two-dimensional/axisymmetric time accurate code that incorporates many of the advances in DSMC over the past decade. The current focus is on flows produced in ground-based facilities at Mach 12 and 16 test conditions with nitrogen as the test gas and the test models at zero incidence. Results presented highlight the sensitivity of the calculations to grid resolution, sensitivity to physical modeling parameters, and comparison with experimental measurements. Information is provided concerning the flow structure and surface results for the extent of separation, heating, pressure, and skin friction.
Simultaneous Measurement of Thermal Conductivity and Specific Heat in a Single TDTR Experiment
NASA Astrophysics Data System (ADS)
Sun, Fangyuan; Wang, Xinwei; Yang, Ming; Chen, Zhe; Zhang, Hang; Tang, Dawei
2018-01-01
Time-domain thermoreflectance (TDTR) technique is a powerful thermal property measurement method, especially for nano-structures and material interfaces. Thermal properties can be obtained by fitting TDTR experimental data with a proper thermal transport model. In a single TDTR experiment, thermal properties with different sensitivity trends can be extracted simultaneously. However, thermal conductivity and volumetric heat capacity usually have similar trends in sensitivity for most materials; it is difficult to measure them simultaneously. In this work, we present a two-step data fitting method to measure the thermal conductivity and volumetric heat capacity simultaneously from a set of TDTR experimental data at single modulation frequency. This method takes full advantage of the information carried by both amplitude and phase signals; it is a more convenient and effective solution compared with the frequency-domain thermoreflectance method. The relative error is lower than 5 % for most cases. A silicon wafer sample was measured by TDTR method to verify the two-step fitting method.
Preliminary Investigation of Ice Shape Sensitivity to Parameter Variations
NASA Technical Reports Server (NTRS)
Miller, Dean R.; Potapczuk, Mark G.; Langhals, Tammy J.
2005-01-01
A parameter sensitivity study was conducted at the NASA Glenn Research Center's Icing Research Tunnel (IRT) using a 36 in. chord (0.91 m) NACA-0012 airfoil. The objective of this preliminary work was to investigate the feasibility of using ice shape feature changes to define requirements for the simulation and measurement of SLD icing conditions. It was desired to identify the minimum change (threshold) in a parameter value, which yielded an observable change in the ice shape. Liquid Water Content (LWC), drop size distribution (MVD), and tunnel static temperature were varied about a nominal value, and the effects of these parameter changes on the resulting ice shapes were documented. The resulting differences in ice shapes were compared on the basis of qualitative and quantitative criteria (e.g., mass, ice horn thickness, ice horn angle, icing limits, and iced area). This paper will provide a description of the experimental method, present selected experimental results, and conclude with an evaluation of these results, followed by a discussion of recommendations for future research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Detwiler, Russell L.; Glass, Robert J.; Pringle, Scott E.
Understanding of single and multi-phase flow and transport in fractures can be greatly enhanced through experimentation in transparent systems (analogs or replicas) where light transmission techniques yield quantitative measurements of aperture, solute concentration, and phase saturation fields. Here we quanti@ aperture field measurement error and demonstrate the influence of this error on the results of flow and transport simulations (hypothesized experimental results) through saturated and partially saturated fractures. find that precision and accuracy can be balanced to greatly improve the technique and We present a measurement protocol to obtain a minimum error field. Simulation results show an increased sensitivity tomore » error as we move from flow to transport and from saturated to partially saturated conditions. Significant sensitivity under partially saturated conditions results in differences in channeling and multiple-peaked breakthrough curves. These results emphasize the critical importance of defining and minimizing error for studies of flow and transpoti in single fractures.« less
Medium-energy heavy-ion single-event-burnout imaging of power MOSFETs
NASA Astrophysics Data System (ADS)
Musseau, O.; Torres, A.; Campbell, A. B.; Knudson, A. R.; Buchner, S.; Fischer, B.; Schlogl, M.; Briand, P.
1999-12-01
We present the first experimental determination of the SEB sensitive area in a power MOSFET irradiated with a high-LET heavy-ion microbeam. We used a spectroscopy technique to perform coincident measurements of the charge collected in both source and drain junctions together, with a nondestructive technique (current limitation). The resulting charge collection images are related to the physical structure of the individual cells. These experimental data reveal the complex 3-dimensional behavior of a real structure, which can not easily be simulated using available tools. As the drain voltage is increased, the onset of burnout is reached, characterized by a sudden change in the charge collection image. "Hot spots" are observed where the collected charge reaches its maximum value. Those spots, due to burnout triggering events, correspond to areas where the silicon is degraded through thermal effects along a single ion track. This direct observation of SEB sensitive areas as applications for, either device hardening, by modifying doping profiles or layout of the cells, or for code calibration and device simulation.
Experimental Study of Grit Particle Enhancement in Non-Shock Ignition
NASA Astrophysics Data System (ADS)
Browning, Richard V.; Peterson, Paul D.; Roemer, Edward L.; Oldenborg, Michael R.; Thompson, Darla G.; Deluca, Racci
2006-07-01
The drop weight impact test is the most commonly used configuration for evaluating sensitivity of explosives to non-shock ignition. Although developed 60 years ago and widely used both as a material compression test and as a test bed for understanding the ignition process itself, little is known about the flow mechanisms or involvement of grit particles as sensitizing agents. In this paper, we present the results of a series of experiments designed to study the flow mechanisms and events leading up to ignition. The experimental configuration used involves two pellet sizes, 3 and 5 mm in diameter, tested with three conditions: (1) smooth steel anvils, (2) standard flint sandpaper, and (3) shed grit particles loaded between the steel anvils and the pellet faces. Diagnostics include optical micrographs, and scanning electron micrographs. Un-reacted samples show a variety of morphologies, including what appear to be quenched reaction sites, even at very low drop heights. Quasi-static crushing experiments were also done to quantify load-time histories.
Experimental Study of Grit Particle Enhancement in Non-Shock Ignition of PBX 9501
NASA Astrophysics Data System (ADS)
Peterson, Paul
2005-07-01
The drop weight impact test is the most commonly used configuration for evaluating sensitivity of explosives to non-shock ignition. Although developed 60 years ago and widely used both as a material compression test and as a test bed for understanding the ignition process itself, little is known about the flow mechanisms or involvement of grit particles as sensitizing agents. In this paper we present the results of a series of experiments designed to study the flow mechanisms and events leading up to ignition. The experimental configuration used involves two pellet sizes, 3 and 5 mm in diameter, tested in three conditions, (1) with smooth steel anvils, (2) with standard flint sandpaper, and (3) with shed grit particles loaded between the steel anvils and the pellet faces. Diagnostics include optical micrographs, and scanning electron micrographs. Un-reacted samples show a variety of morphologies, including what appear to be quenched reaction sites, even at very low drop heights. Quasi-static crushing experiments were also done to quantify load-time histories.
Miner, Daniel C; Triesch, Jochen
2014-01-01
The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results.
Miner, Daniel C.; Triesch, Jochen
2014-01-01
The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results. PMID:25414647
Subbotsky, Eugene; Slater, Elizabeth
2011-04-01
Six- and nine-yr.-old children (n=28 of each) were divided into equal experimental and control groups. The experimental groups were shown a film with a magical theme, and the control groups were shown a film with a nonmagical theme. All groups then were presented with a choice task requiring them to discriminate between ordinary and fantastic visual displays on a computer screen. Statistical analyses indicated that mean scores for correctly identifying the ordinary and fantastic displays were significantly different between experimental and control groups. The children in the experimental groups who watched the magical film had significantly higher scores on correct identifications than children in the control groups who watched the nonmagical film for both age groups. The results suggest that watching films with a magical theme might enhance children's sensitivity toward the fantasy/reality distinction.
NASA Astrophysics Data System (ADS)
Barone, F.; Giordano, G.; Acernese, F.; Romano, R.
2018-03-01
In this paper, we present some innovative and general strategies for the control of benches and platforms, that the introduction of the new class of monolithic UNISA Folded Pendulum is now making it possible, also in terms of environmental conditions, like ultra-high-vacuum (UHV), cryogenics and harsh environments. In particular, we present and discuss a parametric analysis of the control models in connection with the sensors limitations in terms of sensitivity and band. Finally, we present and discuss some experimental laboratory tests on a laboratory platform, underlining the present advantages and the expected future improvements.
High sensitive pulse oximeter-spectrophotometer for laser-optical dosimetry in biology and medicine
NASA Astrophysics Data System (ADS)
Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.; Mamilov, S. A.; Plaksiy, Yu. S.
2006-03-01
High sensitive multi channel pulse oxymeter - spectrophotometer for control of the local tissue oxygen saturation is presented. Due to an original method of data storing and processing the accuracy of measurements 3-4 times are increased in compare with similar systems. This system is used for registration of the local changes of arterial blood saturation with oxygen under effect of low intensity laser radiation. It is shown that the photodissociation of oxyhemoglobin in cutaneous blood vessels play a dominant role in the mechanism of biostimulating and therapeutic effect of low intensity laser radiation. The results of experimental investigation in vivo the dependence of arterial oxygen blood saturation on temperature and the wavelength of laser radiation are presented. It is suggested that dosimetry for laser therapy could be base on regulation of local concentration of free oxygen in tissue.
NASA Astrophysics Data System (ADS)
De Cesare, M.; Di Leva, A.; Del Vecchio, A.; Gialanella, L.
2018-03-01
Thermal protection systems (TPSs) of spacecrafts, either for single use or reusable, experience wear by ablation and erosion, due to the high heat fluxes during a re-entry phase in the atmosphere. The determination of the wear rate is a crucial point, which is presently mainly possible in aerospace on-ground measurements by means of invasive diagnostics. The purpose of this paper is to present novel contactless, online, high-sensitivity and non-intrusive diagnostics for wear measurements based on radioactive tracers. We propose the technique for future on-ground experiments that might later be developed to perform in-flight TPSs monitoring, thus significantly increasing the safety of the aerospace vehicles. The basic ideas of the method, its sensitivity investigated by GEANT4 simulations, and the future experimental validation are outlined.
SAMPA Chip: the New 32 Channels ASIC for the ALICE TPC and MCH Upgrades
NASA Astrophysics Data System (ADS)
Adolfsson, J.; Ayala Pabon, A.; Bregant, M.; Britton, C.; Brulin, G.; Carvalho, D.; Chambert, V.; Chinellato, D.; Espagnon, B.; Hernandez Herrera, H. D.; Ljubicic, T.; Mahmood, S. M.; Mjörnmark, U.; Moraes, D.; Munhoz, M. G.; Noël, G.; Oskarsson, A.; Osterman, L.; Pilyar, A.; Read, K.; Ruette, A.; Russo, P.; Sanches, B. C. S.; Severo, L.; Silvermyr, D.; Suire, C.; Tambave, G. J.; Tun-Lanoë, K. M. M.; van Noije, W.; Velure, A.; Vereschagin, S.; Wanlin, E.; Weber, T. O.; Zaporozhets, S.
2017-04-01
This paper presents the test results of the second prototype of SAMPA, the ASIC designed for the upgrade of read-out front end electronics of the ALICE Time Projection Chamber (TPC) and Muon Chamber (MCH). SAMPA is made in a 130 nm CMOS technology with 1.25 V nominal voltage supply and provides 32 channels, with selectable input polarity, and three possible combinations of shaping time and sensitivity. Each channel consists of a Charge Sensitive Amplifier, a semi-Gaussian shaper and a 10-bit ADC; a Digital Signal Processor provides digital filtering and compression capability. In the second prototype run both full chip and single test blocks were fabricated, allowing block characterization and full system behaviour studies. Experimental results are here presented showing agreement with requirements for both the blocks and the full chip.
Mizoguchi, Izuru; Ohashi, Mio; Chiba, Yukino; Hasegawa, Hideaki; Xu, Mingli; Owaki, Toshiyuki; Yoshimoto, Takayuki
2017-01-01
The use of animal models in chemical safety testing will be significantly limited due to the recent introduction of the 3Rs principle of animal experimentation in research. Although several in vitro assays to predict the sensitizing potential of chemicals have been developed, these methods cannot distinguish chemical respiratory sensitizers and skin sensitizers. In the present study, we describe a novel in vitro assay that can discriminate respiratory sensitizers from chemical skin sensitizers by taking advantage of the fundamental difference between their modes of action, namely the development of the T helper 2 immune response, which is critically important for respiratory sensitization. First, we established a novel three-dimensional (3D) coculture system of human upper airway epithelium using a commercially available scaffold. It consists of human airway epithelial cell line BEAS-2B, immature dendritic cells (DCs) derived from human peripheral blood CD14 + monocytes, and human lung fibroblast cell line MRC-5. Respective cells were first cultured in individual scaffolds and subsequently assembled into a 3D multi-cell tissue model to more closely mimic the in vivo situation. Then, three typical chemicals that are known respiratory sensitizers (ortho-phthaldialdehyde, hexamethylene diisocyanate, and trimellitic anhydride) and skin sensitizers (oxazolone, formaldehyde, and dinitrochlorobenzene) were added individually to the 3D coculture system. Immunohistochemical analysis revealed that DCs do not migrate into other scaffolds under the experimental conditions. Therefore, the 3D structure was disassembled and real-time reverse transcriptase-PCR analysis was performed in individual scaffolds to analyze the expression levels of molecules critical for Th2 differentiation such as OX40 ligand (OX40L), interleukin (IL)-4, IL-10, IL-33, and thymic stromal lymphopoietin. Both sensitizers showed similarly augmented expression of DC maturation markers (e.g., CD86), but among these molecules, OX40L expression in DCs was most consistently and significantly enhanced by respiratory sensitizers as compared to that by skin sensitizers. Thus, we have established a 3D coculture system mimicking the airway upper epithelium that may be successfully applied to discriminate chemical respiratory sensitizers from skin sensitizers by measuring the critical molecule for Th2 differentiation, OX40L, in DCs.
77 FR 23135 - 2,4-D; Order Denying NRDC's Petition To Revoke Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-18
... cannot be determined (``non-threshold effects''). Because EPA identified only threshold effect risks for... uncertainty or safety factors \\1\\ in conjunction with experimental toxicity data in assessing risk to humans... difference in sensitivity between humans and experimental animals (i.e., inter-species sensitivity) and...
Study of sintering temperature on the structure of silicon carbide membrane
NASA Astrophysics Data System (ADS)
Sadighzadeh, A.; Mashayekhan, Sh.; Nedaie, B.; Ghorashi, A. H.
2014-09-01
Study of the microstructure of silicon carbide (SiC) membrane as a function of sintering temperature and the percentage amount of additive kaolin is the outcome of the experimental fabrications presented in this paper. The SEM micrographs are used to investigate the impact of above parameters on the porosity of membrane. The experimental results show that the rise in the temperature causes more sintering of powder particles, growing granules, augmentation of the number of pores and consequently increasing the total porosity of membrane. Using XRD analyses, it is found that SiC amorphous phase is highly sensitive to the temperature and its crystallization physically grows with temperature increase.
Tracer attenuation in groundwater
NASA Astrophysics Data System (ADS)
Cvetkovic, Vladimir
2011-12-01
The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.
An experimental investigation of Iosipescu specimen for composite materials
NASA Technical Reports Server (NTRS)
Ho, H.; Tsai, M. Y.; Morton, J.; Farley, G. L.
1991-01-01
A detailed experimental evaluation of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Moire interferometry is employed to determine the deformation of unidirectional and cross-ply graphite-epoxy specimens. The results of the moire experiments are compared to those from the traditional strain-gage method. It is shown that the strain-gage readings from one surface of a specimen together with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to twisting. A localized hybrid analysis is introduced to perform efficient reduction of moire data, producing whole-field strain distributions in the specimen test sections.
Experimental measurement of cooling tower emissions using image processing of sensitive papers
NASA Astrophysics Data System (ADS)
Ruiz, J.; Kaiser, A. S.; Ballesta, M.; Gil, A.; Lucas, M.
2013-04-01
Cooling tower emissions are harmful for several reasons such as air polluting, wetting, icing and solid particle deposition, but mainly due to human health hazards (i.e. Legionella). There are several methods for measuring drift drops. This paper is focussed on the sensitive paper technique, which is suitable in low drift scenarios and real conditions. The lack of an automatic classification method motivated the development of a digital image process algorithm for the Sensitive Paper method. This paper presents a detailed description of this method, in which, drop-like elements are identified by means of the Canny edge detector combined with some morphological operations. Afterwards, the application of a J48 decision tree is proposed as one of the most relevant contributions. This classification method allows us to discern between stains whose origin is a drop and stains whose origin is not a drop. The method is applied to a real case and results are presented in terms of drift and PM10 emissions. This involves the calculation of the main features of the droplet distribution at the cooling tower exit surface in terms of drop size distribution data, cumulative mass distribution curve and characteristic drop diameters. The Log-normal and the Rosin-Rammler distribution functions have been fitted to the experimental data collected in the tests and it can been concluded that the first one is the most suitable for experimental data among the functions tested (whereas the second one is less suitable). Realistic PM10 calculations include the measurement of drift emissions and Total Dissolved Solids as well as the size and number of drops. Results are compared to the method proposed by the U.S. Environmental Protection Agency assessing its overestimation. Drift emissions have found to be 0.0517% of the recirculating water, which is over the Spanish standards limit (0.05%).
Doherty, James M.; Frantz, Kyle J.
2012-01-01
Objectives Early onset of heroin use during adolescence might increase chances of later drug addiction. Prior work from our laboratory suggests, however, that adolescent male rats are actually less sensitive than adults to some enduring effects of heroin self-administration. In the present study, we tested two likely correlates of sensitivity to behavioral reinforcement in rats: physical withdrawal and locomotor sensitization. Methods Adolescent (35 days old at start) and adult (79 days old) male Sprague-Dawley rats were administered escalating doses of heroin, increasing from 1.0 to 8.0 mg/kg (i.p.) every 12 hr, across 13 days. Somatic signs of spontaneous withdrawal were scored 12 and 24 hr after the last injection, then every 24 hr for 5 days; locomotion was recorded concurrently. Challenge injections of heroin (1 mg/kg i.p.) were given at 4 points: as the first of the escalating doses (day 1), at days 7 and 13 during the escalating regimen, and after 12 days of forced abstinence. Body mass and food intake were measured throughout experimentation. Results A heroin withdrawal syndrome was not observed among adolescents as it was among adults, including somatic signs as well as reduced locomotion, body mass, and food intake. On the other hand, heroin-induced locomotor sensitization did not differ across ages. Conclusion Reduced withdrawal is consistent with the attenuated reinforcing effects of heroin among adolescent male rats that we reported previously. Thus, it is possible that adolescent rats could reveal important neuroprotective factors for use in treatment of heroin dependence. PMID:22941050
Arnbjerg, Jacob; Paterson, Martin J; Nielsen, Christian B; Jørgensen, Mikkel; Christiansen, Ove; Ogilby, Peter R
2007-07-05
Singlet molecular oxygen, O2(a1Deltag), can be efficiently produced in a photosensitized process using either one- or two-photon irradiation. The aromatic ketone 1-phenalenone (PN) is an established one-photon singlet oxygen sensitizer with many desirable attributes for use as a standard. In the present work, photophysical properties of two other aromatic ketones, pyrene-1,6-dione (PD) and benzo[cd]pyren-5-one (BP), are reported and compared to those of PN. Both PD and BP sensitize the production of singlet oxygen with near unit quantum efficiency in a nonpolar (toluene) and a polar (acetonitrile) solvent. With their more extensive pi networks, the one-photon absorption spectra for PD and BP extend out to longer wavelengths than that for PN, thus providing increased flexibility for sensitizer excitation over the range approximately 300-520 nm. Moreover, PD and BP have much larger two-photon absorption cross sections than PN over the range 655-840 nm which, in turn, results in amounts of singlet oxygen that are readily detected in optical experiments. One- and two-photon absorption spectra of PD and BP obtained using high-level calculations model the salient features of the experimental data well. In particular, the ramifications of molecular symmetry are clearly reflected in both the experimental and calculated spectra. The use of PD and BP as standards for both the one- and two-photon photosensitized production of singlet oxygen is expected to facilitate the development of new sensitizers for application in singlet-oxygen-based imaging experiments.
Ultra-low frequency Raman spectroscopy of SWNTs under high pressure
NASA Astrophysics Data System (ADS)
Shen, Y.; Quirke, N.; Zerulla, D.
2016-09-01
Radial deformation phenomena of carbon nanotubes (CNTs) are attracting increased attention because even minimal changes of the CNT's cross section can result in significant changes of their electronic and optical properties. It is therefore important to have the ability to sensitively probe and characterize this radial deformation. High pressure Raman spectroscopy offers a general and powerful method to study such effects in SWNTs. In this experimental work, we focus in particular on one theoretically predicted Raman vibrational mode, the so-called "Squash Mode" (SM), named after its vibrational mode pattern, which has an E2g symmetry representation and exists at shifts below the radial breathing mode (RBM) region. The Squash mode was predicted to be more sensitive to environmental changes than the RBM. Here we report on a detailed, experimental detection of SMs of aligned SWNT arrays with peaks as close as 18 cm-1 to the laser excitation energy. Furthermore, we investigate how the SM of aligned CNT arrays reacts when exposed to a high pressure environment of up to 9 GPa. The results confirm the theoretical predictions regarding the angular and polarization dependent variations of the SM's intensity with respect to their excitation. Furthermore, clear Raman upshifts of SM under pressures of up to 9 GPa are presented. The relative changes of these upshifts, and hence the sensitivity, are much higher than that of RBMs because of larger radial displacement of some of the participating carbon atoms during the SM vibration. These novel ultra-sensitive Raman SM shifts of SWNTs provide enhanced sensitivity and demonstrate new opportunities for nano-optical sensors applications.
Effect of infrared laser in the prevention and treatment of paresthesia in orthognathic surgery.
Prazeres, Lady Dayane Kalline Travassos; Muniz, Yuri Victor Siqueira; Barros, Keylla Marinho Albuquerque; Gerbi, Marleny Elizabeth Marquez de Martinez; Laureano Filho, José Rodrigues
2013-05-01
Orthognathic surgery is the surgical procedure that makes correcting deformities of the bones in the region of the maxilla and mandible a reality in the Brazilian dentistry. However, this type of surgery usually involves paresthesia in the postoperative period, concerning the surgeons who perform them and generating discomfort to patients. This study aimed at evaluating the effect of infrared laser (830 nm) in the prevention and treatment of paresthesias after orthognathic surgery. Six patients underwent orthognathic surgery: the experimental group composed of 4 patients and the control group that did not receive laser therapy composed of 2 patients. The experimental group received laser applications during the transoperative and 12 postoperative sessions. Tests for mechanical (deep and shallow) and thermal (cold) sensitivity were performed in the preoperative and postoperative period (during 12 sessions) in the lip and chin areas by the same operator. The paresthesia was classified into 1, strong; 2, moderate; 3, mild; and 4, absent, through the patient's response to stimuli. The results showed that all patients had no disturbance of sensitivity in the preoperative period, but paresthesia was presented at various levels in the postoperative period. Both groups showed recovery of deep mechanical sensitivity within a shorter time interval compared with the superficial mechanical and thermal sensitivity. However, at the 12th assessment, patients who underwent the laser therapy showed better reduction in the level of paresthesia or even complete regression of this. The laser, therefore, brought benefits to the treatment of paresthesia, accelerating the return of neurosensorial sensitivity.
NASA Astrophysics Data System (ADS)
Piruzyan, L. A.; Mikhailovskiy, Ye. M.; Piruzyan, A. L.
1999-12-01
The priority concept of the laser histochemical surgery as a potentially novel line in medicine is presented. The histochemical stains, selectively coloring some targets (address substrates), that are cells or their biochemical ingredients, sensitize them to the laser irradiation. Such sensitization to laser irradiation by staining turns the colored targets into targets for the laser beam. The action of the irradiation onto its specific targets beats out of the cell its ingredients which participate in a pathology process. In particular, the beating of a stained ferment out of the general stage of biochemical processes characteristic for the pathology interrupts their currence. The laser beam, when beating out its stained targets without any damage of the unstained tissues, acts like a scalpel that cuts off affected tissues not brushing healthy ones. A scheme for testing stains as sensitizers of the `address substrates' to the laser irradiation is presented. As the criterion of the stain sensitization the fact was chosen of absence or weakness of pathomorphologic and biochemical signs of the disease in an experimental model of the pathology irradiated with laser after a stain use, while the pathology signs are present in a control sample. The basis is done for study of the histochemical stains as potential means for the laser histochemical surgery of disseminated sclerosis, mucopolysaccharidosis, hypercholesterolemia, myocardial infarction, cardiosclerosis, caries and parodontosis.
Research on dual-parameter optical fiber sensor based on few-mode fiber with two down-tapers
NASA Astrophysics Data System (ADS)
Wang, Xue; Tong, Zhengrong; Zhang, Weihua; Xue, Lifang
2017-10-01
A dual-parameter optical fiber sensor, which is fabricated by sandwiching a segment of few-mode fiber (FMF) with two down-tapers between two segments of standard single-mode fibers (SMFs), is investigated theoretically and experimentally. The two down-tapers on the FMF can enhance the evanescent field, making the sensor more sensitive to changes in the external environment. The refractive index (RI) and temperature are measured simultaneously using the different sensitivities of the two dips in this experimental interference spectrum. The measured temperature sensitivities are 0.097 and 0.114 nm/°C, and the RI sensitivities are -97.43 and -108.07 nm/RIU, respectively. Meanwhile, the simple SMF-FMF-SMF structure is also measured. By comparing the experimental results of the two structures, the sensitivities of the proposed structure based on the dual-taper FMF are significantly improved. In addition, the sensor is easy to fabricate and cost effective.
Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goncharov, Vasily; Hall, Gregory
Here, we have developed phase-sensitive signal detection and processing algorithms for Fourier transform spectrometers fitted with supercontinuum sources for applications requiring ultimate sensitivity. Similar to well-established approach of source noise cancellation through balanced detection of monochromatic light, our method is capable of reducing the relative intensity noise of polychromatic light by 40 dB. Unlike conventional balanced detection, which relies on differential absorption measured with a well matched pair of photo-detectors, our algorithm utilizes phase-sensitive differential detection on a single photodiode and is capable of the real-time correction for instabilities in supercontinuum spectral structure over a broad range of wavelengths. Inmore » the resulting method is universal in terms of applicable wavelengths and compatible with commercial spectrometers. We present a proof-of-principle experimental« less
Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode
Goncharov, Vasily; Hall, Gregory
2016-08-25
Here, we have developed phase-sensitive signal detection and processing algorithms for Fourier transform spectrometers fitted with supercontinuum sources for applications requiring ultimate sensitivity. Similar to well-established approach of source noise cancellation through balanced detection of monochromatic light, our method is capable of reducing the relative intensity noise of polychromatic light by 40 dB. Unlike conventional balanced detection, which relies on differential absorption measured with a well matched pair of photo-detectors, our algorithm utilizes phase-sensitive differential detection on a single photodiode and is capable of the real-time correction for instabilities in supercontinuum spectral structure over a broad range of wavelengths. Inmore » the resulting method is universal in terms of applicable wavelengths and compatible with commercial spectrometers. We present a proof-of-principle experimental« less
LAVA Simulations for the AIAA Sonic Boom Prediction Workshop
NASA Technical Reports Server (NTRS)
Housman, Jeffrey A.; Sozer, Emre; Moini-Yekta , Shayan; Kiris, Cetin C.
2014-01-01
Computational simulations using the Launch Ascent and Vehicle Aerodynamics (LAVA) framework are presented for the First AIAA Sonic Boom Prediction Workshop test cases. The framework is utilized with both structured overset and unstructured meshing approaches. The three workshop test cases include an axisymmetric body, a Delta Wing-Body model, and a complete low-boom supersonic transport concept. Solution sensitivity to mesh type and sizing, and several numerical convective flux discretization choices are presented and discussed. Favorable comparison between the computational simulations and experimental data of nearand mid-field pressure signatures were obtained.
TeV radiation from the Crab nebula and other matters
NASA Technical Reports Server (NTRS)
Lamb, R. C.
1990-01-01
The detection of the Crab Nebula via the Cherenkov imaging technique places TeV astronomy on a secure observational footing. The motivation for TeV observations, a discussion of the atmospheric Cherenkov technique, the experimental details of the Crab Nebula detection, and its scientific implications are presented. The present dilemma of VHE/UHE astronomy is that the Crab appears to be the only source whose showers match theoretical expectations. The situation will be clarified as improved ground-based detectors come on-line with sensitivities matching those of the GRO (Gamma Ray Observatory) instruments.
Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer.
Das, Bhargab; Chandra, Vikash
2016-10-10
We present an experimental comparative study of the two most commonly used fiber Bragg grating (FBG) sensor interrogation techniques: a charge-coupled device (CCD) spectrometer and a fiber Mach-Zehnder interferometer (F-MZI). Although the interferometric interrogation technique is historically known to offer the highest sensitivity measurements, very little information exists regarding how it compares with the current commercially available spectral-characteristics-based interrogation systems. It is experimentally established here that the performance of a modern-day CCD spectrometer interrogator is very close to a F-MZI interrogator with the capability of measuring Bragg wavelength shifts with sub-picometer-level accuracy. The results presented in this research study can further be used as a guideline for choosing between the two FBG sensor interrogator types for small-amplitude dynamic perturbation measurements down to nano-level strain.
Imprints of fluctuating proton shapes on flow in proton-lead collisions at the LHC
NASA Astrophysics Data System (ADS)
Mäntysaari, Heikki; Schenke, Björn; Shen, Chun; Tribedy, Prithwish
2017-09-01
Results for particle production in √{ s} = 5.02TeV p + Pb collisions at the Large Hadron Collider within a combined classical Yang-Mills and relativistic viscous hydrodynamic calculation are presented. We emphasize the importance of sub-nucleon scale fluctuations in the proton projectile to describe the experimentally observed azimuthal harmonic coefficients vn, demonstrating their sensitivity to the proton shape. We stress that the proton shape and its fluctuations are not free parameters in our calculations. Instead, they have been constrained using experimental data from HERA on exclusive vector meson production. Including temperature dependent shear and bulk viscosities, as well as UrQMD for the low temperature regime, we present results for mean transverse momenta, harmonic flow coefficients for charged hadrons and identified particles, as well as Hanbury-Brown-Twiss radii.
NASA Astrophysics Data System (ADS)
Wu, Yu; Zhang, Hongpeng
2017-12-01
A new microfluidic chip is presented to enhance the sensitivity of a micro inductive sensor, and an approach to coil inductance change calculation is introduced for metal particle detection in lubrication oil. Electromagnetic knowledge is used to establish a mathematical model of an inductive sensor for metal particle detection, and the analytic expression of coil inductance change is obtained by a magnetic vector potential. Experimental verification is carried out. The results show that copper particles 50-52 µm in diameter have been detected; the relative errors between the theoretical and experimental values are 7.68% and 10.02% at particle diameters of 108-110 µm and 50-52 µm, respectively. The approach presented here can provide a theoretical basis for an inductive sensor in metal particle detection in oil and other areas of application.
The ALBA spectroscopic LEEM-PEEM experimental station: layout and performance
Aballe, Lucia; Foerster, Michael; Pellegrin, Eric; Nicolas, Josep; Ferrer, Salvador
2015-01-01
The spectroscopic LEEM-PEEM experimental station at the CIRCE helical undulator beamline, which started user operation at the ALBA Synchrotron Light Facility in 2012, is presented. This station, based on an Elmitec LEEM III microscope with electron imaging energy analyzer, permits surfaces to be imaged with chemical, structural and magnetic sensitivity down to a lateral spatial resolution better than 20 nm with X-ray excited photoelectrons and 10 nm in LEEM and UV-PEEM modes. Rotation around the surface normal and application of electric and (weak) magnetic fields are possible in the microscope chamber. In situ surface preparation capabilities include ion sputtering, high-temperature flashing, exposure to gases, and metal evaporation with quick evaporator exchange. Results from experiments in a variety of fields and imaging modes will be presented in order to illustrate the ALBA XPEEM capabilities. PMID:25931092
Solar atmospheric neutrinos and the sensitivity floor for solar dark matter annihilation searches
DOE Office of Scientific and Technical Information (OSTI.GOV)
Argüelles, C.A.; De Wasseige, G.; Fedynitch, A.
Cosmic rays interacting in the solar atmosphere produce showers that result in a flux of high-energy neutrinos from the Sun. These form an irreducible background to indirect solar WIMP self-annihilation searches, which look for heavy dark matter particles annihilating into final states containing neutrinos in the Solar core. This background will eventually create a sensitivity floor for indirect WIMP self-annihilation searches analogous to that imposed by low-energy solar neutrino interactions for direct dark matter detection experiments. We present a new calculation of the flux of solar atmospheric neutrinos with a detailed treatment of systematic uncertainties inherent in solar atmospheric showermore » evolution, and we use this to derive the sensitivity floor for indirect solar WIMP annihilation analyses. We find that the floor lies less than one order of magnitude beyond the present experimental limits on spin-dependent WIMP-proton cross sections for some mass points, and that the high-energy solar atmospheric neutrino flux may be observable with running and future neutrino telescopes.« less
Geometry optimization for micro-pressure sensor considering dynamic interference
NASA Astrophysics Data System (ADS)
Yu, Zhongliang; Zhao, Yulong; Li, Lili; Tian, Bian; Li, Cun
2014-09-01
Presented is the geometry optimization for piezoresistive absolute micro-pressure sensor. A figure of merit called the performance factor (PF) is defined as a quantitative index to describe the comprehensive performances of a sensor including sensitivity, resonant frequency, and acceleration interference. Three geometries are proposed through introducing islands and sensitive beams into typical flat diaphragm. The stress distributions of sensitive elements are analyzed by finite element method. Multivariate fittings based on ANSYS simulation results are performed to establish the equations about surface stress, deflection, and resonant frequency. Optimization by MATLAB is carried out to determine the dimensions of the geometries. Convex corner undercutting is evaluated. Each PF of the three geometries with the determined dimensions is calculated and compared. Silicon bulk micromachining is utilized to fabricate the prototypes of the sensors. The outputs of the sensors under both static and dynamic conditions are tested. Experimental results demonstrate the rationality of the defined performance factor and reveal that the geometry with quad islands presents the highest PF of 210.947 Hz1/4. The favorable overall performances enable the sensor more suitable for altimetry.
NASA Technical Reports Server (NTRS)
Boyadjian, N. G.; Dallakyan, P. Y.; Garyaka, A. P.; Mamidjanian, E. A.
1985-01-01
A method for calculating the average spatial and energy characteristics of hadron-lepton cascades in the atmosphere is described. The results of calculations for various strong interaction models of primary protons and nuclei are presented. The sensitivity of the experimentally observed extensive air showers (EAS) characteristics to variations of the elementary act parameters is analyzed.
ERIC Educational Resources Information Center
Brown, Robert T., Ed.; Clark, Barbara G., Ed.
This guide contains a collection of laboratory and field inquiries designed to promote ecological awareness, sensitivity, and understanding. The activities compiled by 28 teachers are for use in teaching biology at the secondary level. They are presented in a "recipe" form to make it possible for teachers without prior experience or training to…
High-Rate Strong-Signal Quantum Cryptography
NASA Technical Reports Server (NTRS)
Yuen, Horace P.
1996-01-01
Several quantum cryptosystems utilizing different kinds of nonclassical lights, which can accommodate high intensity fields and high data rate, are described. However, they are all sensitive to loss and both the high rate and the strong-signal character rapidly disappear. A squeezed light homodyne detection scheme is proposed which, with present-day technology, leads to more than two orders of magnitude data rate improvement over other current experimental systems for moderate loss.
ERIC Educational Resources Information Center
Taber, Douglass F.; Frankowski, Kevin J.
2006-01-01
A modified experimental procedure for the one-step synthesis that is suitable for the undergraduate organic lab is presented. In the course of work towards the more routine use of air-sensitive organometallic complexes such as the Grubb's catalyst, the natural product (E)-4-(4-hydroxy-3-methoxyphenyl) but-2-en-ol, 4, was synthesized.
Nanoparticle light scattering on interferometric surfaces
NASA Astrophysics Data System (ADS)
Hayrapetyan, K.; Arif, K. M.; Savran, C. A.; Nolte, D. D.
2011-03-01
We present a model based on Mie Surface Double Interaction (MSDI) to explore bead-based detection mechanisms using imaging and scanning. The application goal of this work is to explore the trade-offs between the sensitivity and throughput among various detection methods. Experimentally we use thermal oxide on silicon to establish and control surface interferometric conditions. Surface-captured gold beads are detected using Molecular Interferometric Imaging (MI2) and Spinning-Disc Interferometry (SDI).
PMT waveform modeling at the Daya Bay experiment
NASA Astrophysics Data System (ADS)
Sören, Jetter; Dan, Dwyer; Jiang, Wen-Qi; Liu, Da-Wei; Wang, Yi-Fang; Wang, Zhi-Min; Wen, Liang-Jian
2012-08-01
Detailed measurements of Hamamatsu R5912 photomultiplier signals are presented, including the single photoelectron charge response, waveform shape, nonlinearity, saturation, overshoot, oscillation, prepulsing, and afterpulsing. The results were used to build a detailed model of the PMT signal characteristics over a wide range of light intensities. Including the PMT model in simulated Daya Bay particle interactions shows no significant systematic effects that are detrimental to the experimental sensitivity.
Shearlet Features for Registration of Remotely Sensed Multitemporal Images
NASA Technical Reports Server (NTRS)
Murphy, James M.; Le Moigne, Jacqueline
2015-01-01
We investigate the role of anisotropic feature extraction methods for automatic image registration of remotely sensed multitemporal images. Building on the classical use of wavelets in image registration, we develop an algorithm based on shearlets, a mathematical generalization of wavelets that offers increased directional sensitivity. Initial experimental results on LANDSAT images are presented, which indicate superior performance of the shearlet algorithm when compared to classical wavelet algorithms.
Experimental Investigation of a High Pressure Ratio Aspirated Fan Stage
NASA Technical Reports Server (NTRS)
Merchant, Ali; Kerrebrock, Jack L.; Adamczyk, John J.; Braunscheidel, Edward
2004-01-01
The experimental investigation of an aspirated fan stage designed to achieve a pressure ratio of 3.4:1 at 1500 ft/sec is presented in this paper. The low-energy viscous flow is aspirated from diffusion-limiting locations on the blades and flowpath surfaces of the stage, enabling a very high pressure ratio to be achieved in a single stage. The fan stage performance was mapped at various operating speeds from choke to stall in a compressor facility at fully simulated engine conditions. The experimentally determined stage performance, in terms of pressure ratio and corresponding inlet mass flow rate, was found to be in good agreement with the three-dimensional viscous computational prediction, and in turn close to the design intent. Stage pressure ratios exceeding 3:1 were achieved at design speed, with an aspiration flow fraction of 3.5 percent of the stage inlet mass flow. The experimental performance of the stage at various operating conditions, including detailed flowfield measurements, are presented and discussed in the context of the computational analyses. The sensitivity of the stage performance and operability to reduced aspiration flow rates at design and off design conditions are also discussed.
Torsional Vibration in the National Wind Technology Center’s 2.5-Megawatt Dynamometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sethuraman, Latha; Keller, Jonathan; Wallen, Robb
2016-08-31
This report documents the torsional drivetrain dynamics of the NWTC's 2.5-megawatt dynamometer as identified experimentally and as calculated using lumped parameter models using known inertia and stiffness parameters. The report is presented in two parts beginning with the identification of the primary torsional modes followed by the investigation of approaches to damp the torsional vibrations. The key mechanical parameters for the lumped parameter models and justification for the element grouping used in the derivation of the torsional modes are presented. The sensitivities of the torsional modes to different test article properties are discussed. The oscillations observed from the low-speed andmore » generator torque measurements were used to identify the extent of damping inherently achieved through active and passive compensation techniques. A simplified Simulink model of the dynamometer test article integrating the electro-mechanical power conversion and control features was established to emulate the torque behavior that was observed during testing. The torque response in the high-speed, low-speed, and generator shafts were tested and validated against experimental measurements involving step changes in load with the dynamometer operating under speed-regulation mode. The Simulink model serves as a ready reference to identify the torque sensitivities to various system parameters and to explore opportunities to improve torsional damping under different conditions.« less
Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop
NASA Astrophysics Data System (ADS)
Geslot, Benoit; Gruel, Adrien; Bréaud, Stéphane; Leconte, Pierre; Blaise, Patrick
2018-01-01
Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop) and another one where the power is free to drift (open loop). First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.
High sensitivity test of the Pauli Exclusion Principle for electrons with X-ray spectroscopy (VIP2)
NASA Astrophysics Data System (ADS)
Marton, Johann; VIP2 Collaboration
2015-10-01
The Pauli Exclusion Principle (PEP) is one of the most fundamental rules in physics and it has various important consequences ranging from atomic and subatomic systems to the stability of matter and stellar objects like neutron stars. Due to many observations This rule must be valid to an extremely high degree and consequently no violations were found so far. On the other hand a simple explanation of PEP is still missing. Many experimental investigations based on different assumptions were performed to search for a tiny PEP violation in various systems. The experiment VIP2 at the Gran Sasso underground laboratory (LNGS of INFN) is designed to test the PEP for electrons with high sensitivity by searching for forbidden X-ray transitions in copper atoms. This experiment aims to improve the PEP violation limit obtained with our preceding experiment VIP by orders of magnitude. The experimental method, comparison of the VIP result with different PEP searches and the present status of the VIP2 experiment will be presented. We acknowledge the support from the: HadronPhysics FP6 (506078), HadronPhysics2 FP7 (227431), HadronPhysics3 (283286) projects, EU COST Action 1006 (Fundamental Problems in Quantum Physics) and the Austrian Science Fund (FWF).
Polarization-polarization correlation measurement --- Experimental test of the PPCO methods
NASA Astrophysics Data System (ADS)
Droste, Ch.; Starosta, K.; Wierzchucka, A.; Morek, T.; Rohoziński, S. G.; Srebrny, J.; Wesolowski, E.; Bergstrem, M.; Herskind, B.
1998-04-01
A significant fraction of modern multidetector arrays used for "in-beam" gamma-ray spectroscopy consist of a detectors which are sensitive to linear polarization of gamma quanta. This yields the opportunity to carry out correlation measurements between the gamma rays registered in polarimeters to get information concerning spins and parities of excited nuclear states. The aim of the present work was to study the ability of the polarization- polarization correlation method (the PPCO method). The correlation between the linear polarization of one gamma quantum and the polarization of the second quantum emitted in a cascade from an oriented nucleus (due to a heavy ion reaction) was studied in detail. The appropriate formulae and methods of analysis are presented. The experimental test of the method was performed using the EUROGAM II array. The CLOVER detectors are the parts of the array used as polarimeters. The ^164Yb nucleus was produced via the ^138Ba(^30Si, 4n) reaction. It was found that the PPCO method together with the standard DCO analysis and the polarization- direction correlation method (PDCO) can be helpful for spin, parity and multipolarity assignments. The results suggest that the PPCO method can be applied to modern spectrometers in which a large number of detectors (e.g. CLOVER) are sensitive to polarization of gamma rays.
Fernandes, R O; Dreher, G J; Schenkel, P C; Fernandes, T R G; Ribeiro, M F M; Araujo, A S R; Belló-Klein, A
2011-10-01
This study was conducted to analyse the redox status and redox-sensitive proteins that may contribute to a non-genomic mechanism of cardiac hypertrophy induction by hyperthyroidism. Wistar rats, treated with L-thyroxine (T4) during 2 weeks (12 mg·l(-1) in drinking water), presented cardiac hypertrophy (68% higher than control), without signals of liver or lung congestion. Myocardial reduction of the reduced glutathione: oxidized glutathione (GSSG) ratio (45%) (redox status) and elevation in hydrogen peroxide concentration (H(2) O(2) ) (28%) were observed in hyperthyroid as compared with the control. No significant difference was found in thioredoxin (Trx), Trx reductase activity and Nrf2 (a transcriptional factor) protein expression between groups. Redox-sensitive proteins, quantified using Western blot, presented the following results: increased p-ERK: total extracellular-regulated kinase (ERK) (200%) and Bax:Bcl-2 (62%) ratios and reduced total-Akt (63%) and p-Akt (53%) expressions in the hyperthyroid rats as compared with the control. The redox imbalance, associated with increased immunocontent of a protein related to maladaptative growth (ERK) and reduced immunocontent of protein related to cytoprotection/survival (Akt), may suggest that the molecular scenario could favour the decompensation process of cardiac hypertrophy induced by experimental hyperthyroidism. Copyright © 2011 John Wiley & Sons, Ltd.
What experimental experience affects dogs' comprehension of human communicative actions?
Hauser, Marc D; Comins, Jordan A; Pytka, Lisa M; Cahill, Donal P; Velez-Calderon, Sofia
2011-01-01
Studies of dogs report that individuals reliably respond to the goal-directed communicative actions (e.g., pointing) of human experimenters. All of these studies use some version of a multi-trial approach, thereby allowing for the possibility of rapid learning within an experimental session. The experiments reported here ask whether dogs can respond correctly to a communicative action based on only a single presentation, thereby eliminating the possibility of learning within the experimental context. We tested 173 dogs. For each dog reaching our test criteria, we used a single presentation of six different goal-directed actions within a session, asking whether they correctly follow to a target goal (container with concealed food) a (1) distal hand point, (2) step toward one container, (3) hand point to one container followed by step toward the other, (4) step toward one container and point to the other, (5) distal foot point with the experimenter's hands free, and (6) distal foot point with the experimenter's hands occupied. Given only a single presentation, dogs selected the correct container when the experimenter hand pointed, foot pointed with hands occupied, or stepped closer to the target container, but failed on the other actions, despite using the same method. The fact that dogs correctly followed foot pointing with hands occupied, but not hands free, suggests that they are sensitive to environmental constraints, and use this information to infer rational, goal-directed action. We discuss these results in light of the role of experience in recognizing communicative gestures, as well as the significance of coding criteria for studies of canine competence. Copyright © 2010 Elsevier B.V. All rights reserved.
Test-retest reliability of infant event related potentials evoked by faces.
Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C
2017-04-05
Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Piezoresistive in-line integrated force sensors for on-chip measurement and control
NASA Astrophysics Data System (ADS)
Teichert, Kendall; Waterfall, Tyler; Jensen, Brian; Howell, Larry; McLain, Tim
2007-04-01
This paper presents the design, fabrication, and testing of a force sensor for integrated use with thermomechanical in-plane microactuators. The force sensor is designed to be integrated with the actuator and fabricated in the same batch fabrication process. This sensor uses the piezoresistive property of silicon as a sensing signal by directing the actuation force through two thin legs, producing a tensile stress. This tensile load produces a resistance change in the thin legs by the piezoresistive effect. The resistance change is linearly correlated with the applied force. The device presented was designed by considering both its piezoresistive sensitivity and out-of- plane torsional stability. A design trade-off exists between these two objectives in that longer legs are more sensitive yet less stable. Fabrication of the sensor design was done using the MUMPs process. This paper presents experimental results from this device and a basic model for comparison with previously attained piezoresistive data. The results validate the concept of integral sensing using the piezoresistive property of silicon.
On the role of cost-sensitive learning in multi-class brain-computer interfaces.
Devlaminck, Dieter; Waegeman, Willem; Wyns, Bart; Otte, Georges; Santens, Patrick
2010-06-01
Brain-computer interfaces (BCIs) present an alternative way of communication for people with severe disabilities. One of the shortcomings in current BCI systems, recently put forward in the fourth BCI competition, is the asynchronous detection of motor imagery versus resting state. We investigated this extension to the three-class case, in which the resting state is considered virtually lying between two motor classes, resulting in a large penalty when one motor task is misclassified into the other motor class. We particularly focus on the behavior of different machine-learning techniques and on the role of multi-class cost-sensitive learning in such a context. To this end, four different kernel methods are empirically compared, namely pairwise multi-class support vector machines (SVMs), two cost-sensitive multi-class SVMs and kernel-based ordinal regression. The experimental results illustrate that ordinal regression performs better than the other three approaches when a cost-sensitive performance measure such as the mean-squared error is considered. By contrast, multi-class cost-sensitive learning enables us to control the number of large errors made between two motor tasks.
High-sensitivity bend angle measurements using optical fiber gratings.
Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang
2013-07-20
We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.
Pramipexole-induced disruption of behavioral processes fundamental to intertemporal choice.
Johnson, Patrick S; Stein, Jeffrey S; Smits, Rochelle R; Madden, Gregory J
2013-05-01
Evaluating the effects of presession drug administration on intertemporal choice in nonhumans is a useful approach for identifying compounds that promote impulsive behavior in clinical populations, such as those prescribed the dopamine agonist pramipexole (PPX). Based on the results of previous studies, it is unclear whether PPX increases rats' impulsive choice or attenuates aspects of stimulus control. The present study was designed to experimentally isolate behavioral processes fundamental to intertemporal choice and challenge them pharmacologically with PPX administration. In Experiment 1, the hypothesis that PPX increases impulsive choice as a result of enhanced sensitivity to reinforcer delays was tested and disconfirmed. That is, acute PPX diminished delay sensitivity in a manner consistent with disruption of stimulus control whereas repeated PPX had no effect on delay sensitivity. Experiments 2 and 3 elaborated upon this finding by examining the effects of repeated PPX on rats' discrimination of response-reinforcer contingencies and reinforcer amounts, respectively. Accuracy of both discriminations was reduced by PPX. Collectively these results provide no support for past studies that have suggested PPX increases impulsive choice. Instead, PPX impairs stimulus control over choice behavior. The behavioral approach adopted herein could be profitably integrated with genetic and other biobehavioral models to advance our understanding of impulsive behavior associated with drug administration. © Society for the Experimental Analysis of Behavior.
Henderson, Rory; Day-Lewis, Frederick D.; Abarca, Elena; Harvey, Charles F.; Karam, Hanan N.; Liu, Lanbo; Lane, John W.
2010-01-01
Electrical resistivity imaging has been used in coastal settings to characterize fresh submarine groundwater discharge and the position of the freshwater/salt-water interface because of the relation of bulk electrical conductivity to pore-fluid conductivity, which in turn is a function of salinity. Interpretation of tomograms for hydrologic processes is complicated by inversion artifacts, uncertainty associated with survey geometry limitations, measurement errors, and choice of regularization method. Variation of seawater over tidal cycles poses unique challenges for inversion. The capabilities and limitations of resistivity imaging are presented for characterizing the distribution of freshwater and saltwater beneath a beach. The experimental results provide new insight into fresh submarine groundwater discharge at Waquoit Bay National Estuarine Research Reserve, East Falmouth, Massachusetts (USA). Tomograms from the experimental data indicate that fresh submarine groundwater discharge may shut down at high tide, whereas temperature data indicate that the discharge continues throughout the tidal cycle. Sensitivity analysis and synthetic modeling provide insight into resolving power in the presence of a time-varying saline water layer. In general, vertical electrodes and cross-hole measurements improve the inversion results regardless of the tidal level, whereas the resolution of surface arrays is more sensitive to time-varying saline water layer.
Volkow, Nora D; Wang, Gene-Jack; Fowler, Joanna S; Tomasi, Dardo; Telang, Frank; Baler, Ruben
2010-09-01
Based on brain imaging findings, we present a model according to which addiction emerges as an imbalance in the information processing and integration among various brain circuits and functions. The dysfunctions reflect (a) decreased sensitivity of reward circuits, (b) enhanced sensitivity of memory circuits to conditioned expectations to drugs and drug cues, stress reactivity, and (c) negative mood, and a weakened control circuit. Although initial experimentation with a drug of abuse is largely a voluntary behavior, continued drug use can eventually impair neuronal circuits in the brain that are involved in free will, turning drug use into an automatic compulsive behavior. The ability of addictive drugs to co-opt neurotransmitter signals between neurons (including dopamine, glutamate, and GABA) modifies the function of different neuronal circuits, which begin to falter at different stages of an addiction trajectory. Upon exposure to the drug, drug cues or stress this results in unrestrained hyperactivation of the motivation/drive circuit that results in the compulsive drug intake that characterizes addiction.
Detonation properties of nitromethane/diethylenetriamine solution
NASA Astrophysics Data System (ADS)
Mochalova, V.; Utkin, A.; Lapin, S.
2017-01-01
The results of the experimental determination of the detonation parameters of nitromethane (NM) with diethylenetriamine (DETA) solution are presented in this work. With the using of a laser interferometer VISAR the stability of detonation waves, the detonation velocity and the reaction time at the concentration of DETA from 0 to 60 weight percentage were investigated. It is shown that the stability of detonation waves is retained up to 25% DETA, at that the characteristic reaction time is reduced by about half at the addition of several percentage of the sensitizer to NM and then remains almost constant. The increase of the detonation velocity in the vicinity of the small, about 0.1%, concentrations of sensitizer is recorded.
2013-01-01
As a highly sensitive strain gauge element, GaAs-based resonant tunneling diode (RTD) has already been applied in microelectromechanical system (MEMS) sensors. Due to poor mechanical properties and high cost, GaAs-based material has been limited in applications as the substrate for MEMS. In this work, we present a method to fabricate the GaAs-based RTD on Si substrate. From the experimental results, it can be concluded that the piezoresistive coefficient achieved with this method reached 3.42 × 10−9 m2/N, which is about an order of magnitude higher than the Si-based semiconductor piezoresistors. PMID:23651496
NASA Astrophysics Data System (ADS)
Rachevski, Alexandre; Ahangarianabhari, Mahdi; Bellutti, Pierluigi; Bertuccio, Giuseppe; Brigo, Elena; Bufon, Jernej; Carrato, Sergio; Castoldi, Andrea; Cautero, Giuseppe; Fabiani, Sergio; Giacomini, Gabriele; Gianoncelli, Alessandra; Giuressi, Dario; Guazzoni, Chiara; Kourousias, George; Liu, Chang; Menk, Ralf Hendrik; Montemurro, Giuseppe Vito; Picciotto, Antonino; Piemonte, Claudio; Rashevskaya, Irina; Shi, Yongbiao; Stolfa, Andrea; Vacchi, Andrea; Zampa, Gianluigi; Zampa, Nicola; Zorzi, Nicola
2016-07-01
We developed a trapezoidal shaped matrix with 8 cells of Silicon Drift Detectors (SDD) featuring a very low leakage current (below 180 pA/cm2 at 20 °C) and a shallow uniformly implanted p+ entrance window that enables sensitivity down to few hundreds of eV. The matrix consists of a completely depleted volume of silicon wafer subdivided into 4 square cells and 4 half-size triangular cells. The energy resolution of a single square cell, readout by the ultra-low noise SIRIO charge sensitive preamplifier, is 158 eV FWHM at 5.9 keV and 0 °C. The total sensitive area of the matrix is 231 mm2 and the wafer thickness is 450 μm. The detector was developed in the frame of the INFN R&D project ReDSoX in collaboration with FBK, Trento. Its trapezoidal shape was chosen in order to optimize the detection geometry for the experimental requirements of low energy X-ray fluorescence (LEXRF) spectroscopy, aiming at achieving a large detection angle. We plan to exploit the complete detector at the TwinMic spectromicroscopy beamline at the Elettra Synchrotron (Trieste, Italy). The complete system, composed of 4 matrices, increases the solid angle coverage of the isotropic photoemission hemisphere about 4 times over the present detector configuration. We report on the layout of the SDD matrix and of the experimental set-up, as well as the spectroscopic performance measured both in the laboratory and at the experimental beamline.
A model of excitation and adaptation in bacterial chemotaxis.
Hauri, D C; Ross, J
1995-01-01
We present a model of the chemotactic mechanism of Escherichia coli that exhibits both initial excitation and eventual complete adaptation to any and all levels of stimulus ("exact" adaptation). In setting up the reaction network, we use only known interactions and experimentally determined cytosolic concentrations. Whenever possible, rate coefficients are first assigned experimentally measured values; second, we permit some variation in these rate coefficients by using a multiple-well optimization technique and incremental adjustment to obtain values that are sufficient to engender initial response to stimuli (excitation) and an eventual return of behavior to baseline (adaptation). The predictions of the model are similar to the observed behavior of wild-type bacteria in regard to the time scale of excitation in the presence of both attractant and repellent. The model predicts a weaker response to attractant than that observed experimentally, and the time scale of adaptation does not depend as strongly upon stimulant concentration as does that for wild-type bacteria. The mechanism responsible for long-term adaptation is local rather than global: on addition of a repellent or attractant, the receptor types not sensitive to that attractant or repellent do not change their average methylation level in the long term, although transient changes do occur. By carrying out a phenomenological simulation of bacterial chemotaxis, we find that the model is insufficiently sensitive to effect taxis in a gradient of attractant. However, by arbitrarily increasing the sensitivity of the motor to the tumble effector (phosphorylated CheY), we can obtain chemotactic behavior. Images FIGURE 6 FIGURE 7 PMID:7696522
Racial and ethnic differences in experimental pain sensitivity: systematic review and meta-analysis.
Kim, Hee Jun; Yang, Gee Su; Greenspan, Joel D; Downton, Katherine D; Griffith, Kathleen A; Renn, Cynthia L; Johantgen, Meg; Dorsey, Susan G
2017-02-01
Our objective was to describe the racial and ethnic differences in experimental pain sensitivity. Four databases (PubMed, EMBASE, the Cochrane Central Register of Controlled Trials, and PsycINFO) were searched for studies examining racial/ethnic differences in experimental pain sensitivity. Thermal-heat, cold-pressor, pressure, ischemic, mechanical cutaneous, electrical, and chemical experimental pain modalities were assessed. Risk of bias was assessed using the Agency for Healthcare Research and Quality guideline. Meta-analysis was used to calculate standardized mean differences (SMDs) by pain sensitivity measures. Studies comparing African Americans (AAs) and non-Hispanic whites (NHWs) were included for meta-analyses because of high heterogeneity in other racial/ethnic group comparisons. Statistical heterogeneity was assessed by subgroup analyses by sex, sample size, sample characteristics, and pain modalities. A total of 41 studies met the review criteria. Overall, AAs, Asians, and Hispanics had higher pain sensitivity compared with NHWs, particularly lower pain tolerance, higher pain ratings, and greater temporal summation of pain. Meta-analyses revealed that AAs had lower pain tolerance (SMD: -0.90, 95% confidence intervals [CIs]: -1.10 to -0.70) and higher pain ratings (SMD: 0.50, 95% CI: 0.30-0.69) but no significant differences in pain threshold (SMD: -0.06, 95% CI: -0.23 to 0.10) compared with NHWs. Estimates did not vary by pain modalities, nor by other demographic factors; however, SMDs were significantly different based on the sample size. Racial/ethnic differences in experimental pain sensitivity were more pronounced with suprathreshold than with threshold stimuli, which is important in clinical pain treatment. Additional studies examining mechanisms to explain such differences in pain tolerance and pain ratings are needed.
Night-shift work is associated with increased pain perception.
Matre, Dagfinn; Knardahl, Stein; Nilsen, Kristian Bernhard
2017-05-01
Objectives The aim of the present study was to determine whether shift workers exhibit increased perception of experimentally induced pain after working night shifts. Methods The study was a paired cross-over design with two sleep conditions, after at least two nights of habitual sleep and after two consecutive night shifts at work. Fifty-three nurses in rotating shift work participated. The sensitivity to electrically induced pain, heat pain, cold pain, pressure pain and pain inhibition was determined experimentally in each sleep condition. Sleepiness and vigilance were also assessed. Results Night-shift work (NSW) increased the sensitivity to electrically induced pain and heat pain (P≤0.001). Relative to habitual sleep, electrically induced pain increased by 22.3% and heat pain increased by 26.5%. The sensitivity to cold and pressure pain did not change, changes relative to habitual sleep was <5% (P>0.5). Pain inhibition was 66.9% stronger after NSW versus after habitual sleep (P<0.001). Sleepiness (measured with the Karolinska Sleepiness Scale) increased from 4.1 after habitual sleep to 6.9 after NSW (P<0.001). Vigilance decreased after NSW, measured as a 0.03-second decrease in reaction time (P<0.005). Conclusions Changes in pain sensitivity after NSW is measurable with clinically relevant effect sizes and may be an important marker for studies comparing the physiological effects of different shift work schedules. Explanations for the differential effect on different pain modalities should be a focus for future studies.
NASA Astrophysics Data System (ADS)
Fu, Guangwei; Li, Qifeng; Li, Yunpu; Yang, Jiandong; Fu, Xinghu; Bi, Weihong; Li, Yanjun
2016-10-01
A tension sensor of Photonic Crystal Fiber(PCF) is presented based on core-offset splicing and waist-enlarged fiber taper. The tension response characteristics of the sensor are studied experimentally. To analyzing the modal interference, many samples with different PCF lengths between the two splicing areas, different core-offset distances and different waist-enlarged fiber taper diameters are fabricated and tested. When the tension range is 0 to 4000μɛ, the results show that the spectrum is blue shift with the increasing of the axial tension. The sensitivity is-2.1 pm/μɛ. The experimental results show that the tension sensitivity can be not influenced by the PCF lengths, the core-offset distances.The waist-enlarged fiber taper diameters and the tension sensor is very sensitive to axial tension and the relationship between the wavelength shift and tension is linearity. To determine the number of the interfering modes, the transmission spectra of these sensor is transformed by the fast fourier transform (FFT) method. There are several peaks in the spatial frequency spectra at these sensors. Only one cladding mode is dominantly excited, while the other cladding modes are weak. The spatial frequency is proportional to the differential mode group index. Compared with the traditional fiber sensor, this sensor has some advantages including the easily fabricated, simple structure and high sensitivity. It can be used in industrial production, building monitoring, aerospace and other fields.
de Freitas, Patricia Moreira; Menezes, Andressa Nery; da Mota, Ana Carolina Costa; Simões, Alyne; Mendes, Fausto Medeiros; Lago, Andrea Dias Neves; Ferreira, Leila Soares; Ramos-Oliveira, Thayanne Monteiro
2016-01-01
The present study investigated how a hybrid light source (LED/laser) influences temperature variation on the enamel surfaces during 35% hydrogen peroxide (HP) bleaching. Effects on the whitening effectiveness and tooth sensitivity were analyzed. Twenty-two volunteers were randomly assigned to two different treatments in a split-mouth experimental model: group 1 (control), 35% HP; group 2 (experimental), 35% HP + LED/laser. Color evaluation was performed before treatment, and 7 and 14 days after completion of bleaching, using a color shade scale. Tooth sensitivity was assessed using a visual analog scale (VAS; before, immediately, and 24 hours after bleaching). During the bleaching treatment, thermocouple channels positioned on the tooth surfaces recorded the temperature. Data on color and temperature changes were subjected to statistical analysis (α = 5%). Tooth sensitivity data were evaluated descriptively. Groups 1 and 2 showed mean temperatures (± standard deviation) of 30.7 ± 1.2 °C and 34.1 ± 1.3 °C, respectively. It was found that there were statistically significant differences between the groups, with group 2 showing higher mean variation (P < .0001). The highest temperature variation occurred for group 2, with an increase of 5.3 °C at the enamel surface. The color change results showed no differences in bleaching between the two treatment groups (P = .177). The variation of the average temperature during the treatments was not statistically associated with color variation (P = .079). Immediately after bleaching, it was found that 36.4% of the subjects in group 2 had mild to moderate sensitivity. In group 1, 45.5% showed moderate sensitivity. In both groups, the sensitivity ceased within 24 hours. Hybrid light source (LED/ laser) influences temperature variation on the enamel surface during 35% HP bleaching and is not related to greater tooth sensitivity.
Experimental evidence of human recreational disturbance effects on bird-territory establishment.
Bötsch, Yves; Tablado, Zulima; Jenni, Lukas
2017-07-12
The worldwide increase in human outdoor activities raises concerns for wildlife. Human disturbances, even at low levels, are likely to impact species during sensitive periods of the annual cycle. However, experimental studies during the putative sensitive period of territory establishment of birds which not only investigate low disturbance levels, but which also exclude the effect of habitat modification (e.g. walking trails) are lacking. Here, we experimentally disturbed birds in forest plots by walking through twice a day during territory establishment. Later we compared the breeding bird community of experimentally disturbed plots with that of undisturbed control plots. We discovered that the number of territories (-15.0%) and species richness (-15.2%) in disturbed plots were substantially reduced compared with control plots. Species most affected included those sensitive to human presence (assessed by flight-initiation distances), open-cup nesters and above-ground foragers. Long-distance migrants, however, were unaffected due to their arrival after experimental disturbance took place. These findings highlight how territory establishment is a sensitive period for birds, when even low levels of human recreation may be perceived as threatening, and alter settlement decisions. This can have important implications for the conservation of species, which might go unnoticed when focusing only on already established birds. © 2017 The Author(s).
Analysis of Photothermal Characterization of Layered Materials: Design of Optimal Experiments
NASA Technical Reports Server (NTRS)
Cole, Kevin D.
2003-01-01
In this paper numerical calculations are presented for the steady-periodic temperature in layered materials and functionally-graded materials to simulate photothermal methods for the measurement of thermal properties. No laboratory experiments were performed. The temperature is found from a new Green s function formulation which is particularly well-suited to machine calculation. The simulation method is verified by comparison with literature data for a layered material. The method is applied to a class of two-component functionally-graded materials and results for temperature and sensitivity coefficients are presented. An optimality criterion, based on the sensitivity coefficients, is used for choosing what experimental conditions will be needed for photothermal measurements to determine the spatial distribution of thermal properties. This method for optimal experiment design is completely general and may be applied to any photothermal technique and to any functionally-graded material.
Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises
Chen, Xiyuan; Zhang, Hong; Zou, Sheng
2016-01-01
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz1/2 was successfully achieved by suppressing noises and optimizing parameters. PMID:27322272
How to specify and measure sensitivity in Distributed Acoustic Sensing (DAS)?
NASA Astrophysics Data System (ADS)
Gabai, Haniel; Eyal, Avishay
2017-04-01
In Rayleigh-scattering-based Distributed Acoustic Sensing (DAS) an optical fiber is transformed into an array of thousands of 'virtual microphones'. This approach has gained tremendous popularity in recent years and is one of the most successful examples of a fiber-optic sensing method which made its way from the academia to the market. Despite the great amount of work done in this field, sensitivity, which is ones of the most critical parameters of any sensing technique, was rarely investigated in this context. In particular, little attention was given to its random characteristics. Without careful consideration of the random aspects of DAS, any attempt to specify its sensitivity or to compare between different DAS modalities is of limited value. Recently we introduced a new statistical parameter which defines DAS sensitivity and enables comparison between the performances of different DAS systems. In this paper we generalize the previous parameter and give a broader, simple and intuitive definition to DAS sensitivity. An important attribute of these parameters is that they can be easily extracted from the static backscatter profile of the sensing fiber. In the paper we derive the relation between DAS sensitivity and the static backscatter profile and present an experimental verification of this relation.
Allergic sensitization: screening methods
2014-01-01
Experimental in silico, in vitro, and rodent models for screening and predicting protein sensitizing potential are discussed, including whether there is evidence of new sensitizations and allergies since the introduction of genetically modified crops in 1996, the importance of linear versus conformational epitopes, and protein families that become allergens. Some common challenges for predicting protein sensitization are addressed: (a) exposure routes; (b) frequency and dose of exposure; (c) dose-response relationships; (d) role of digestion, food processing, and the food matrix; (e) role of infection; (f) role of the gut microbiota; (g) influence of the structure and physicochemical properties of the protein; and (h) the genetic background and physiology of consumers. The consensus view is that sensitization screening models are not yet validated to definitively predict the de novo sensitizing potential of a novel protein. However, they would be extremely useful in the discovery and research phases of understanding the mechanisms of food allergy development, and may prove fruitful to provide information regarding potential allergenicity risk assessment of future products on a case by case basis. These data and findings were presented at a 2012 international symposium in Prague organized by the Protein Allergenicity Technical Committee of the International Life Sciences Institute’s Health and Environmental Sciences Institute. PMID:24739743
Polymer/silica hybrid waveguide temperature sensor based on asymmetric Mach-Zehnder interferometer
NASA Astrophysics Data System (ADS)
Niu, Donghai; Wang, Xibin; Sun, Shiqi; Jiang, Minghui; Xu, Qiang; Wang, Fei; Wu, Yuanda; Zhang, Daming
2018-04-01
A highly sensitive waveguide temperature sensor based on asymmetric Mach-Zehnder interferometer was designed and experimentally demonstrated. The interferometer is based on the polymer/silica hybrid waveguide structure, and Norland Optical Adhesive 73 (NOA 73) was employed as the waveguide core to enhance the temperature sensitivity. The influence of the different length differences between the two interferometer arms on the sensitivity of the sensor was systemically studied. It is shown that the maximum temperature sensitivity of -431 pm °C-1 can be obtained in the range of 25 °C-75 °C, while the length difference is 92 μm. Moreover, the temperature sensitivity contributions from different core materials were also investigated experimentally. It is shown that the waveguide material and microstructure of the device have significant influences on the sensitivity of the waveguide temperature sensor.
NASA Astrophysics Data System (ADS)
Vendittozzi, Cristian; Felli, Ferdinando; Lupi, Carla
2018-05-01
Fiber optics with photo-imprinted Bragg grating have been studied in order to be used as temperature sensors in cryogenic applications. The main disadvantage presented by Fiber Bragg Grating (FBG) sensors is the significant drop in sensitivity as temperature decreases, mainly due to the critical lowering of the thermo-optic coefficient of the fiber and the very low thermal expansion coefficient (CTE) of fused silica at cryogenic temperatures. Thus, especially for the latter, it is important to enhance sensitivity to temperature by depositing a metal coating presenting higher CTE. In this work the thermal sensitivity of metal-coated FBG sensors has been evaluated by considering their elongation within temperature variations in the cryogenic range, as compared to bare fiber sensors. To this purpose, a theoretical model simulating elongation of metal-coated sensors has been developed. The model has been used to evaluate the behaviour of different metals which can be used as coating (Ni, Cu, Al, Zn, Pb and In). The optimal coating thickness has been calculated at different fixed temperature (from 5 K to 100 K) for each metal. It has been found that the metal coating effectiveness depends on thickness and operating temperature in accordance to our previous experimental work and theory suggest.
Kottapalli, Ajay Giri Prakash; Bora, Meghali; Asadnia, Mohsen; Miao, Jianmin; Venkatraman, Subbu S.; Triantafyllou, Michael
2016-01-01
We present the development and testing of superficial neuromast-inspired flow sensors that also attain high sensitivity and resolution through a biomimetic hyaulronic acid-based hydrogel cupula dressing. The inspiration comes from the spatially distributed neuromasts of the blind cavefish that live in completely dark undersea caves; the sensors enable the fish to form three-dimensional flow and object maps, enabling them to maneuver efficiently in cluttered environments. A canopy shaped electrospun nanofibril scaffold, inspired by the cupular fibrils, assists the drop-casting process allowing the formation of a prolate spheroid-shaped artificial cupula. Rheological and nanoindentation characterizations showed that the Young’s modulus of the artificial cupula closely matches the biological cupula (10–100 Pa). A comparative experimental study conducted to evaluate the sensitivities of the naked hair cell sensor and the cupula-dressed sensor in sensing steady-state flows demonstrated a sensitivity enhancement by 3.5–5 times due to the presence of hydrogel cupula. The novel strategies of sensor development presented in this report are applicable to the design and fabrication of other biomimetic sensors as well. The developed sensors can be used in the navigation and maneuvering of underwater robots, but can also find applications in biomedical and microfluidic devices. PMID:26763299
Investigation of an optical sensor for small tilt angle detection of a precision linear stage
NASA Astrophysics Data System (ADS)
Saito, Yusuke; Arai, Yoshikazu; Gao, Wei
2010-05-01
This paper presents evaluation results of the characteristics of the angle sensor based on the laser autocollimation method for small tilt angle detection of a precision linear stage. The sensor consists of a laser diode (LD) as the light source, and a quadrant photodiode (QPD) as the position-sensing detector. A small plane mirror is mounted on the moving table of the stage as a target mirror for the sensor. This optical system has advantages of high sensitivity, fast response speed and the ability for two-axis angle detection. On the other hand, the sensitivity of the sensor is determined by the size of the optical spot focused on the QPD, which is a function of the diameter of the laser beam projected onto the target mirror. Because the diameter is influenced by the divergence of the laser beam, this paper focuses on the relationship between the sensor sensitivity and the moving position of the target mirror (sensor working distance) over the moving stroke of the stage. The main error components that influence the sensor sensitivity are discussed and the optimal conditions of the optical system of the sensor are analyzed. The experimental result about evaluation of the effective working distance is also presented.
ERIC Educational Resources Information Center
Perkins, Kyle
In this paper four classes of procedures for measuring the instructional sensitivity of reading comprehension test items are reviewed. True experimental designs are not recommended because some of the most important reading comprehension variables do not lend themselves to experimental manipulation. "Ex post facto" factorial designs are…
ERIC Educational Resources Information Center
Donovan, Wilberta; Leavitt, Lewis; Taylor, Nicole
2005-01-01
The impact of differences in maternal self-efficacy and infant difficulty on mothers' sensitivity to small changes in the fundamental frequency of an audiotaped infant's cry was explored in 2 experiments. The experiments share in common experimental manipulations of infant difficulty, a laboratory derived measure of maternal efficacy (low,…
Rodrigues, C; Portugal, F C M; Nogueira, J M F
2012-01-30
Static headspace sorptive extraction using polyurethane foams (HSSE(PU)) followed by gas chromatography coupled to mass spectrometry is proposed for volatile analysis. The application of this novel analytical approach to characterize the volatiles profile from roasted coffee samples, selected as model system, revealed remarkable advantages under convenient experimental conditions. The comparison of HSSE(PU) with other well-established procedures, such as headspace sorptive extraction using polydimethylsiloxane (HSSE(PDMS)) and headspace solid phase microextraction using carboxen/polydimethylsiloxane fibers (HS-SPME(CAR/PDMS)), showed that the former presented much higher capacity, sensitivity and even selectivity, where larger abundance and number of roasted coffee volatile compounds (e.g. furans, pyrazines, ketones, acids and pyrroles) could be achieved, under similar experimental conditions. The data presented herein proved, for the first time, that PU foams present great performance for static headspace sorption-based procedures, showing to be an alternative polymeric phase for volatile analysis. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ilchen, M.; Hartmann, G.; Rupprecht, P.
The angle-resolved inner-shell photoionization of R-trifluoromethyloxirane, C 3H 3F 3O, is studied experimentally and theoretically. Thereby, we investigate the photoelectron circular dichroism (PECD) for nearly symmetric O 1s and F 1s electronic orbitals, which are localized on different molecular sites. The respective dichroic β 1 and angular distribution β 2 parameters are measured at the photoelectron kinetic energies from 1 to 16 eV by using variably polarized synchrotron radiation and velocity map imaging spectroscopy. The present experimental results are in good agreement with the outcome of ab initio electronic structure calculations. We report a sizable chiral asymmetry β 1 ofmore » up to about 9% for the K -shell photoionization of oxygen atom. For the individual fluorine atoms, the present calculations predict asymmetries of similar size. However, being averaged over all fluorine atoms, it drops down to about 2%, as also observed in the present experiment. Our study demonstrates a strong emitter and site sensitivity of PECD in the one-photon inner-shell ionization of this chiral molecule.« less
Neutron-antineutron oscillations: Theoretical status and experimental prospects
Phillips, D. G.; Snow, W. M.; Babu, K.; ...
2016-02-01
This paper summarizes the relevant theoretical developments, outlines some ideas to improve experimental searches for free neutron-antineutron oscillations, and suggests avenues for future improvement in the experimental sensitivity.
NASA Astrophysics Data System (ADS)
Liu, Lei; zhang, Zhihua; Wang, Ya; Qin, hao
2018-03-01
The study on the pressure resistance performance of emulsion explosives in deep water can provide theoretical basis for underwater blasting, deep-hole blasting and emulsion explosives development. The sensitizer is an important component of emulsion explosives. By using reusable experimental devices to simulate the charge environment in deep water, the influence of the content of chemical sensitizer on the deep-water pressure resistance performance of emulsion explosives was studied. The experimental results show that with the increasing of the content of chemical sensitizer, the deep-water pressure resistance performance of emulsion explosives gradually improves, and when the pressure is fairly large, the effect is particularly pronounced; in a certain range, with the increase of the content of chemical sensitizer, that emulsion explosives’ explosion performance also gradually improve, but when the content reaches a certain value, the explosion properties declined instead; under the same emulsion matrix condition, when the content of NANO2 is 0.2%, that the emulsion explosives has good resistance to water pressure and good explosion properties. The correctness of the results above was testified in model blasting.
The dye-sensitized solar cell database.
Venkatraman, Vishwesh; Raju, Rajesh; Oikonomopoulos, Solon P; Alsberg, Bjørn K
2018-04-03
Dye-sensitized solar cells (DSSCs) have garnered a lot of attention in recent years. The solar energy to power conversion efficiency of a DSSC is influenced by various components of the cell such as the dye, electrolyte, electrodes and additives among others leading to varying experimental configurations. A large number of metal-based and metal-free dye sensitizers have now been reported and tools using such data to indicate new directions for design and development are on the rise. DSSCDB, the first of its kind dye-sensitized solar cell database, aims to provide users with up-to-date information from publications on the molecular structures of the dyes, experimental details and reported measurements (efficiencies and spectral properties) and thereby facilitate a comprehensive and critical evaluation of the data. Currently, the DSSCDB contains over 4000 experimental observations spanning multiple dye classes such as triphenylamines, carbazoles, coumarins, phenothiazines, ruthenium and porphyrins. The DSSCDB offers a web-based, comprehensive source of property data for dye sensitized solar cells. Access to the database is available through the following URL: www.dyedb.com .
Highly sensitive force sensor based on balloon-like interferometer
NASA Astrophysics Data System (ADS)
Wu, Yue; Xiao, Shiying; Xu, Yao; Shen, Ya; Jiang, Youchao; Jin, Wenxing; Yang, Yuguang; Jian, Shuisheng
2018-07-01
An all-fiber highly sensitive force sensor based on modal interferometer has been presented and demonstrated. The single-mode fiber (SMF) with coating stripped is designed into a balloon-like shape to form a modal interferometer. Due to the bent SMF, the interference occurs between the core mode and cladding modes. With variation of the force applied to the balloon-like interferometer, the bending diameter changes, which caused the wavelength shift of the modal interference. Thus the measurement of the force variation can be achieved by monitoring the wavelength shift. The performances of the interferometer with different bending diameter are experimentally investigated, and the maximum force sensitivity of 24.9 pm/ μ N can be achieved with the bending diameter 14 mm ranging from 0 μ N to 1464.12 μ N. Furthermore, the proposed fiber sensor exhibits the advantages of easy fabrication and low cost, making it a suitable candidate in the optical fiber sensing field.
Numerical Simulation and Mechanical Design for TPS Electron Beam Position Monitors
NASA Astrophysics Data System (ADS)
Hsueh, H. P.; Kuan, C. K.; Ueng, T. S.; Hsiung, G. Y.; Chen, J. R.
2007-01-01
Comprehensive study on the mechanical design and numerical simulation for the high resolution electron beam position monitors are key steps to build the newly proposed 3rd generation synchrotron radiation research facility, Taiwan Photon Source (TPS). With more advanced electromagnetic simulation tool like MAFIA tailored specifically for particle accelerator, the design for the high resolution electron beam position monitors can be tested in such environment before they are experimentally tested. The design goal of our high resolution electron beam position monitors is to get the best resolution through sensitivity and signal optimization. The definitions and differences between resolution and sensitivity of electron beam position monitors will be explained. The design consideration is also explained. Prototype deign has been carried out and the related simulations were also carried out with MAFIA. The results are presented here. Sensitivity as high as 200 in x direction has been achieved in x direction at 500 MHz.
Detector Development for the MARE Neutrino Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galeazzi, M.; Bogorin, D.; Molina, R.
2009-12-16
The MARE experiment is designed to measure the mass of the neutrino with sub-eV sensitivity by measuring the beta decay of {sup 187}Re with cryogenic microcalorimeters. A preliminary analysis shows that, to achieve the necessary statistics, between 10,000 and 50,000 detectors are likely necessary. We have fabricated and characterized Iridium transition edge sensors with high reproducibility and uniformity for such a large scale experiment. We have also started a full scale simulation of the experimental setup for MARE, including thermalization in the absorber, detector response, and optimum filter analysis, to understand the issues related to reaching a sub-eV sensitivity andmore » to optimize the design of the MARE experiment. We present our characterization of the Ir devices, including reproducibility, uniformity, and sensitivity, and we discuss the implementation and capabilities of our full scale simulation.« less
Liu, Bing-Hong; Jiang, Yong-Xiang; Zhu, Xiao-Song; Tang, Xiao-Li; Shi, Yi-Wei
2013-12-30
A new kind of surface plasmon resonance (SPR) sensor based on silver-coated hollow fiber (HF) structure for the detection of liquids with high refractive index (RI) is presented. Liquid sensed medium with high RI is filled in the hollow core of the HF and its RI can be detected by measuring the transmission spectra of the HF SPR sensor. The designed sensors with different silver thicknesses are fabricated and the transmission spectra for filled liquids with different RI are measured to investigate the performances of the sensors. Theoretical analysis is also carried out to evaluate the performance. The simulation results agree well with the experimental results. Factors that might affect sensitivity and detection accuracy of the sensor are discussed. The highest sensitivity achieved is 6,607 nm/RIU, which is comparable to the sensitivities of the other reported fiber SPR sensors.
Vargas-Rodriguez, Everardo; Guzman-Chavez, Ana Dinora; Baeza-Serrato, Roberto
2018-06-04
In this work, a novel tailored algorithm to enhance the overall sensitivity of gas concentration sensors based on the Direct Absorption Tunable Laser Absorption Spectroscopy (DA-ATLAS) method is presented. By using this algorithm, the sensor sensitivity can be custom-designed to be quasi constant over a much larger dynamic range compared with that obtained by typical methods based on a single statistics feature of the sensor signal output (peak amplitude, area under the curve, mean or RMS). Additionally, it is shown that with our algorithm, an optimal function can be tailored to get a quasi linear relationship between the concentration and some specific statistics features over a wider dynamic range. In order to test the viability of our algorithm, a basic C 2 H 2 sensor based on DA-ATLAS was implemented, and its experimental measurements support the simulated results provided by our algorithm.
Operant conditioning of facial displays of pain.
Kunz, Miriam; Rainville, Pierre; Lautenbacher, Stefan
2011-06-01
The operant model of chronic pain posits that nonverbal pain behavior, such as facial expressions, is sensitive to reinforcement, but experimental evidence supporting this assumption is sparse. The aim of the present study was to investigate in a healthy population a) whether facial pain behavior can indeed be operantly conditioned using a discriminative reinforcement schedule to increase and decrease facial pain behavior and b) to what extent these changes affect pain experience indexed by self-ratings. In the experimental group (n = 29), the participants were reinforced every time that they showed pain-indicative facial behavior (up-conditioning) or a neutral expression (down-conditioning) in response to painful heat stimulation. Once facial pain behavior was successfully up- or down-conditioned, respectively (which occurred in 72% of participants), facial pain displays and self-report ratings were assessed. In addition, a control group (n = 11) was used that was yoked to the reinforcement plans of the experimental group. During the conditioning phases, reinforcement led to significant changes in facial pain behavior in the majority of the experimental group (p < .001) but not in the yoked control group (p > .136). Fine-grained analyses of facial muscle movements revealed a similar picture. Furthermore, the decline in facial pain displays (as observed during down-conditioning) strongly predicted changes in pain ratings (R(2) = 0.329). These results suggest that a) facial pain displays are sensitive to reinforcement and b) that changes in facial pain displays can affect self-report ratings.
Finite element simulations of the Portevin Le Chatelier effect in aluminium alloy
NASA Astrophysics Data System (ADS)
Hopperstad, O. S.; Børvik, T.; Berstad, T.; Benallal, A.
2006-08-01
Finite element simulations of the Portevin-Le Chatelier effect in aluminium alloy 5083-H116 are presented and evaluated against existing experimental results. The constitutive model of McCormick (1988) for materials exhibiting negative steady-state strain-rate sensitivity is incorporated into an elastic-viscoplastic model for large plastic deformations and implemented in LS-DYNA for use with the explicit or implicit solver. Axisymmetric tensile specimens loaded at different strain rates are studied numerically, and it is shown that the model predicts the experimental behaviour with reasonable accuracy; including serrated yielding and propagating bands of localized plastic deformation along the gauge length of the specimen at intermediate strain rates.
NASA Technical Reports Server (NTRS)
Stewart, Mark E. M.; Moder, Jeffrey P.
2016-01-01
This paper presents ANSYS Fluent simulation results and analysis for self-pressurization of a flightweight, cryogenic, liquid hydrogen tank in 1-g. These results are compared with experimental data, in particular, pressure evolution and temperature measurements at a set of sensors. The simulations can be analyzed to identify and quantify heat flows in the tank. Heat flows change over time and influence the self-pressurization process. The initial rate of self-pressurization is sensitive to the initial temperature profile near the interface. Uncertainty in saturation pressure data and the accuracy of experimental measurements complicate simulation of self-pressurization. Numerical issues encountered, and their resolution, are also explained.
Effect of amylin in various experimental models of gastric ulcer.
Clementi, G; Caruso, A; Cutuli, V M; Prato, A; de Bernardis, E; Amico-Roxas, M
1997-08-06
Subcutaneous administration of amylin (20-40 micrograms/kg) prevented, in a dose-dependent manner, reserpine- and serotonin-induced gastric damage, but the anti-ulcer effect was not present when lesions were induced by pylorus ligation. The protective effect of amylin was inhibited by pretreatment with capsicin as well as CGRP-(8-37), a calcitonin gene-related peptide (CGRP) and amylin receptor antagonist, and was significantly reduced by domperidone, a dopamine D2 receptor antagonist, or neostigmine, an inhibitor of acetylcholinesterase. Our data suggest that the gastroprotective activity of amylin in some experimental models of gastric ulcers involves capsaicin-sensitive fibers and CGRP receptors. Moreover, the peptide interferes, at least in part, with the dopaminergic and parasympathetic systems.
Time-accurate simulations of a shear layer forced at a single frequency
NASA Technical Reports Server (NTRS)
Claus, R. W.; Huang, P. G.; Macinnes, J. M.
1988-01-01
Calculations are presented for the forced shear layer studied experimentally by Oster and Wygnanski, and Weisbrot. Two different computational approaches are examined: Direct Numerical Simulation (DNS) and Large Eddy Simulation (LES). The DNS approach solves the full three dimensional Navier-Stokes equations for a temporally evolving mixing layer, while the LES approach solves the two dimensional Navier-Stokes equations with a subgrid scale turbulence model. While the comparison between these calculations and experimental data was hampered by a lack of information on the inflow boundary conditions, the calculations are shown to qualitatively agree with several aspects of the experiment. The sensitivity of these calculations to factors such as mesh refinement and Reynolds number is illustrated.
NASA Astrophysics Data System (ADS)
Godinez, H. C.; Rougier, E.; Osthus, D.; Srinivasan, G.
2017-12-01
Fracture propagation play a key role for a number of application of interest to the scientific community. From dynamic fracture processes like spall and fragmentation in metals and detection of gas flow in static fractures in rock and the subsurface, the dynamics of fracture propagation is important to various engineering and scientific disciplines. In this work we implement a global sensitivity analysis test to the Hybrid Optimization Software Suite (HOSS), a multi-physics software tool based on the combined finite-discrete element method, that is used to describe material deformation and failure (i.e., fracture and fragmentation) under a number of user-prescribed boundary conditions. We explore the sensitivity of HOSS for various model parameters that influence how fracture are propagated through a material of interest. The parameters control the softening curve that the model relies to determine fractures within each element in the mesh, as well a other internal parameters which influence fracture behavior. The sensitivity method we apply is the Fourier Amplitude Sensitivity Test (FAST), which is a global sensitivity method to explore how each parameter influence the model fracture and to determine the key model parameters that have the most impact on the model. We present several sensitivity experiments for different combination of model parameters and compare against experimental data for verification.
Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification
Oh, Kyudam; Pak, Nikita; Saunders, D. Curtis; Conrardy, Christina; Landers, James P.; Tong, Suxiang; Forest, Craig R.
2016-01-01
Sensitive identification of the etiology of viral diseases is key to implementing appropriate prevention and treatment. The gold standard for virus identification is the polymerase chain reaction (PCR), a technique that allows for highly specific and sensitive detection of pathogens by exponentially amplifying a specific region of DNA from as little as a single copy through thermocycling a biochemical cocktail. Today, molecular biology laboratories use commercial instruments that operate in 0.5–2 h/analysis using reaction volumes of 5–50 μL contained within polymer tubes or chambers. Towards reducing this volume and maintaining performance, we present a semi-quantitative, systematic experimental study of how PCR yield is affected by tube/chamber substrate, surface-area-to-volume ratio (SA:V), and passivation methods. We perform PCR experiments using traditional PCR tubes as well as using disposable polymer microchips with 1 μL reaction volumes thermocycled using water baths. We report the first oil encapsulation microfluidic PCR method without fluid flow and its application to the first microfluidic amplification of Epstein Barr virus using consensus degenerate primers, a powerful and broad PCR method to screen for both known and novel members of a viral family. The limit of detection is measured as 140 starting copies of DNA from a starting concentration of 3×105 copies/mL, regarded as an accepted sensitivity threshold for diagnostic purposes, and reaction specificity was improved as compared to conventional methods. Also notable, these experiments were conducted with conventional reagent concentrations, rather than commonly spiked enzyme and/or template mixtures. This experimental study of the effects of substrate, SA:V, and passivation, together with sensitive and specific microfluidic PCR with consensus degenerate primers represent advances towards lower cost and higher throughput pathogen screening. PMID:23080522
Classic conditioning of the ventilatory responses in rats.
Nsegbe, E; Vardon, G; Perruchet, P; Gallego, J
1997-10-01
Recent authors have stressed the role of conditioning in the control of breathing, but experimental evidence of this role is still sparse and contradictory. To establish that classic conditioning of the ventilatory responses can occur in rats, we performed a controlled experiment in which a 1-min tone [conditioned stimulus (CS)] was paired with a hypercapnic stimulus [8.5% CO2, unconditioned stimulus (US)]. The experimental group (n = 9) received five paired CS-US presentations, followed by one CS alone to test conditioning. This sequence was repeated six times. The control group (n = 7) received the same number of CS and US, but each US was delivered 3 min after the CS. We observed that after the CS alone, breath duration was significantly longer in the experimental than in the control group and mean ventilation was significantly lower, thus showing inhibitory conditioning. This conditioning may have resulted from the association between the CS and the inhibitory and aversive effects of CO2. The present results confirmed the high sensitivity of the respiratory controller to conditioning processes.
Double beta decay: yesterday, today, tomorrow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fiorini, Ettore
2011-12-16
After a brief introduction on the main features of Double Beta Decay (DBD) and on its origin, its importance is stressed in view of the recent results of experiments on neutrino oscillations. The present experimental situation is reported with special reference to direct experiments and to the comparison of their results with theory. The expectations of the future experiments aiming to reach the sensitivity indicated by neutrino oscillations in the inverse hierarchy hypothesis are discussed.
Linear Self-Referencing Techiques for Short-Optical-Pulse Characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorrer, C.; Kang, I.
2008-04-04
Linear self-referencing techniques for the characterization of the electric field of short optical pulses are presented. The theoretical and practical advantages of these techniques are developed. Experimental implementations are described, and their performance is compared to the performance of their nonlinear counterparts. Linear techniques demonstrate unprecedented sensitivity and are a perfect fit in many domains where the precise, accurate measurement of the electric field of an optical pulse is required.
Tokita, Daisuke; Ebihara, Arata; Nishijo, Miki; Miyara, Kana; Okiji, Takashi
2017-10-01
The purpose of the present study was to compare 2 modes of reciprocal movement (torque-sensitive and time-dependent reciprocal rotation) with continuous rotation in terms of torque and apical force generation during nickel-titanium rotary root canal instrumentation. A custom-made automated root canal instrumentation and torque/force analyzing device was used to prepare simulated canals in resin blocks and monitor the torque and apical force generated in the blocks during preparation. Experimental groups (n = 7, each) consisted of (1) torque-sensitive reciprocal rotation with torque-sensitive vertical movement (group TqR), (2) time-dependent reciprocal rotation with time-dependent vertical movement (group TmR), and (3) continuous rotation with time-dependent vertical movement (group CR). The canals were instrumented with TF Adaptive SM1 and SM2 rotary files (SybronEndo, Orange, CA), and the torque and apical force were measured during instrumentation with SM2. The mean and maximum torque and apical force values were statistically analyzed using 1-way analysis of variance and the Tukey test (α = 0.05). The recordings showed intermittent increases of upward apical force and clockwise torque, indicating the generation and release of screw-in forces. The maximum upward apical force values in group TmR were significantly smaller than those in group CR (P < .05). The maximum torque values in clockwise and counterclockwise directions in groups TqR and TmR were significantly smaller than those in group CR (P < .05). Under the present experimental conditions using TF Adaptive instruments, both torque-sensitive and time-dependent reciprocal rotation generated significantly lower maximum torque and may have advantages in reducing stress generation caused by screw-in forces when compared with continuous rotation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Yasir, Muhammad Naveed; Koh, Bong-Hwan
2018-01-01
This paper presents the local mean decomposition (LMD) integrated with multi-scale permutation entropy (MPE), also known as LMD-MPE, to investigate the rolling element bearing (REB) fault diagnosis from measured vibration signals. First, the LMD decomposed the vibration data or acceleration measurement into separate product functions that are composed of both amplitude and frequency modulation. MPE then calculated the statistical permutation entropy from the product functions to extract the nonlinear features to assess and classify the condition of the healthy and damaged REB system. The comparative experimental results of the conventional LMD-based multi-scale entropy and MPE were presented to verify the authenticity of the proposed technique. The study found that LMD-MPE’s integrated approach provides reliable, damage-sensitive features when analyzing the bearing condition. The results of REB experimental datasets show that the proposed approach yields more vigorous outcomes than existing methods. PMID:29690526
Survey of Experimental Results in High-Contrast Imaging for Future Exoplanet Missions
NASA Technical Reports Server (NTRS)
Lawson, P. R.; Belikov, R.; Cash, W.; Clampin, M.; Glassman, T.; Guyon, O.; Kasdin, N. J.; Kern, B. D.; Lyon, R.; Mawet, D.;
2013-01-01
We present and compare experimental results in high contrast imaging representing the state of the art in coronagraph and starshade technology. These experiments have been undertaken with the goal of demonstrating the capability of detecting Earth-like planets around nearby Sun-like stars. The contrast of an Earth seen in reflected light around a Sun-like star would be about 1.2 x 10(exp -10). Several of the current candidate technologies now yield raw contrasts of 1.0 x 10(exp -9) or better, and so should enable the detection of Earths, assuming a gain in sensitivity in post-processing of a factor of 10. We present results of coronagraph and starshade experiments conducted at visible and infrared wavelengths. Cross-sections of dark fields are directly compared as a function of field angle and bandwidth. The strength and differences of the techniques are compared.
Imprints of fluctuating proton shapes on flow in proton-lead collisions at the LHC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mantysaari, Heikki; Schenke, Bjorn; Shen, Chun
Results for particle production inmore » $$\\sqrt{s}$$ = 5.02 TeV p+Pb collisions at the Large Hadron Collider within a combined classical Yang-Mills and relativistic viscous hydrodynamic calculation are presented. We emphasize the importance of sub-nucleon scale fluctuations in the proton projectile to describe the experimentally observed azimuthal harmonic coefficients v n, demonstrating their sensitivity to the proton shape. We stress that the proton shape and its fluctuations are not free parameters in our calculations. Instead, they have been constrained using experimental data from HERA on exclusive vector meson production. Including temperature dependent shear and bulk viscosities, as well as UrQMD for the low temperature regime, we present results for mean trans-verse momenta, harmonic flow coefficients for charged hadrons and identified particles, as well as Hanbury-Brown-Twiss radii.« less
Yasir, Muhammad Naveed; Koh, Bong-Hwan
2018-04-21
This paper presents the local mean decomposition (LMD) integrated with multi-scale permutation entropy (MPE), also known as LMD-MPE, to investigate the rolling element bearing (REB) fault diagnosis from measured vibration signals. First, the LMD decomposed the vibration data or acceleration measurement into separate product functions that are composed of both amplitude and frequency modulation. MPE then calculated the statistical permutation entropy from the product functions to extract the nonlinear features to assess and classify the condition of the healthy and damaged REB system. The comparative experimental results of the conventional LMD-based multi-scale entropy and MPE were presented to verify the authenticity of the proposed technique. The study found that LMD-MPE’s integrated approach provides reliable, damage-sensitive features when analyzing the bearing condition. The results of REB experimental datasets show that the proposed approach yields more vigorous outcomes than existing methods.
Imprints of fluctuating proton shapes on flow in proton-lead collisions at the LHC
Mantysaari, Heikki; Schenke, Bjorn; Shen, Chun; ...
2017-07-21
Results for particle production inmore » $$\\sqrt{s}$$ = 5.02 TeV p+Pb collisions at the Large Hadron Collider within a combined classical Yang-Mills and relativistic viscous hydrodynamic calculation are presented. We emphasize the importance of sub-nucleon scale fluctuations in the proton projectile to describe the experimentally observed azimuthal harmonic coefficients v n, demonstrating their sensitivity to the proton shape. We stress that the proton shape and its fluctuations are not free parameters in our calculations. Instead, they have been constrained using experimental data from HERA on exclusive vector meson production. Including temperature dependent shear and bulk viscosities, as well as UrQMD for the low temperature regime, we present results for mean trans-verse momenta, harmonic flow coefficients for charged hadrons and identified particles, as well as Hanbury-Brown-Twiss radii.« less
Focusing effect of bent GaAs crystals for γ-ray Laue lenses: Monte Carlo and experimental results
NASA Astrophysics Data System (ADS)
Virgilli, E.; Frontera, F.; Rosati, P.; Bonnini, E.; Buffagni, E.; Ferrari, C.; Stephen, J. B.; Caroli, E.; Auricchio, N.; Basili, A.; Silvestri, S.
2016-02-01
We report on results of observation of the focusing effect from the planes (220) of Gallium Arsenide (GaAs) crystals. We have compared the experimental results with the Monte Carlo simulations of the focusing capability of GaAs tiles performed with a dedicated ray-tracer. The GaAs tiles were bent using a lapping process developed at the cnr/imem - Parma (Italy) in the framework of the laue project, funded by ASI, dedicated to build a broad band Laue lens prototype for astrophysical applications in the hard X-/soft γ-ray energy range (80-600 keV). We present and discuss the results obtained from their characterization, mainly in terms of focusing capability. Bent crystals will significantly increase the signal to noise ratio of a telescope based on a Laue lens, consequently leading to an unprecedented enhancement of sensitivity with respect to the present non focusing instrumentation.
Nishi, Fernanda Ayache; de Oliveira Motta Maia, Flávia; de Souza Santos, Itamar; de Almeida Lopes Monteiro da Cruz, Dina
2017-06-01
Triage is the first assessment and sorting process used to prioritize patients arriving in the emergency department (ED). As a triage tool, the Manchester Triage System (MTS) must have a high sensitivity to minimize the occurrence of under-triage, but must not compromise specificity to avoid the occurrence of overtriage. Sensitivity and specificity of the MTS can be calculated using the frequency of appropriately assigned clinical priority levels for patients presenting to the ED. However, although there are well established criteria for the prioritization of patients with suspected acute coronary syndrome (ACS), several studies have reported difficulties when evaluating patients with this condition. The objective of this review was to synthesize the best available evidence on assessing the sensitivity and specificity of the MTS for screening high-level priority adult patients presenting to the ED with ACS. The current review considered studies that evaluated the use of the MTS in the risk classification of adult patients in the ED. In this review, studies that investigated the priority level, as established by the MTS to screen patients under suspicion of ACS or the sensitivity and specificity of the MTS, for screening patients before the medical diagnosis of ACS were included. This review included both experimental and epidemiological study designs. The results were presented in a narrative synthesis. Six studies were appraised by the independent reviewers. All appraised studies enrolled a consecutive or random sample of patients and presented an overall moderate methodological quality, and all of them were included in this review. A total of 54,176 participants were included in the six studies. All studies were retrospective. Studies included in this review varied in content and data reporting. Only two studies reported sensitivity and specificity values or all the necessary data to calculate sensitivity and specificity. The remaining four studies presented either a sensitivity analysis or the number of true positives and false negatives. However, these four studies were conducted considering only data from patients diagnosed with ACS. Sensitivity values were relatively uniform among the studies: 0.70-0.80. A specificity of 0.59 was reported in the study including only patients with non-traumatic chest pain. On the other hand, in the study that included patients with any complaint, the specificity of MTS to screen patients with ACS was 0.97. The current review demonstrates that the MTS has a moderate sensitivity to evaluate patients with ACS. This may compromise time to treatment in the ED, an important variable in the prognosis of ACS. Atypical presentation of ACS, or high specificity, may also explain the moderate sensitivity demonstrated in this review. However, because of minimal data, it is not possible to confirm this hypothesis. It is difficult to determine the acceptable level of sensitivity or specificity to ensure that a certain triage system is safe.
Solar axion search technique with correlated signals from multiple detectors
Xu, Wenqin; Elliott, Steven R.
2017-01-25
The coherent Bragg scattering of photons converted from solar axions inside crystals would boost the signal for axion-photon coupling enhancing experimental sensitivity for these hypothetical particles. Knowledge of the scattering angle of solar axions with respect to the crystal lattice is required to make theoretical predications of signal strength. Hence, both the lattice axis angle within a crystal and the absolute angle between the crystal and the Sun must be known. In this paper, we examine how the experimental sensitivity changes with respect to various experimental parameters. We also demonstrate that, in a multiple-crystal setup, knowledge of the relative axismore » orientation between multiple crystals can improve the experimental sensitivity, or equivalently, relax the precision on the absolute solar angle measurement. However, if absolute angles of all crystal axes are measured, we find that a precision of 2°–4° will suffice for an energy resolution of σ E = 0.04E and a flat background. Lastly, we also show that, given a minimum number of detectors, a signal model averaged over angles can substitute for precise crystal angular measurements, with some loss of sensitivity.« less
Medium-energy heavy-ion single-event-burnout imaging of power MOSFETs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musseau, O.; Torres, A.; Campbell, A.B.
The authors present the first experimental determination of the SEB sensitive area in a power MOSFET irradiated with a high-LET heavy-ion microbeam. They used a spectroscopy technique to perform coincident measurements of the charge collected in both source and drain junctions together, with a non-destructive technique (current limitation). The resulting charge collection images are related to the physical structure of the individual cells. These experimental data reveal the complex 3-dimensional behavior of a real structure, which can not easily be simulated using available tools. As the drain voltage is increased, the onset of burnout is reached, characterized by a suddenmore » change in the charge collection image. Hot spots are observed where the collected charge reaches its maximum value. Those spots, due to burnout triggering events, correspond to areas where the silicon is degraded through thermal effects along a single ion track. This direct observation of SEB sensitive areas as applications for, either device hardening, by modifying doping profiles or layout of the cells, or for code calibration and device simulation.« less
Lee, Edward H.; Bennett, Jesse H.
1982-01-01
An experimental chemical N-[2-(2-oxo-1-imidazolidinyl)ethyl]-N′-phenylurea (EDU), is an effective protectant against acute and chronic foliar injury due to ozone (03) when sprayed on intact leaves or supplied to the plants through soil application. An 03-sensitive snap bean cultivar (Phaseolus vulgaris L. `Bush Blue Lake 290') was systemically treated with EDU (0, 25, 50, and 100 milligrams per 15-centimeter diameter pot) to determine if EDU-induced or activated protective oxyradical and peroxyl scavenging enzymes. EDU-enhanced tolerance to O3 injury always correlated with increases in superoxide dismutase (SOD) and catalase activities in the leaves. Peroxidase levels correlated more closely with foliar injury. Greater SOD levels in young leves compared to older leaves were associated with lower ozone sensitivities in these tissues. Polyacrylamide slab gel electrophoresis separations and specific determinations of SOD activity showed that EDU-treated plants possessed markedly greater SOD activity than non-treated plants. Tolerant plant tissues may have enhanced enzyme scavenging capabilities for the protection against toxic oxyradicals. Experimental confirmation for the oxyradical theory for O3 phytotoxicity and SOD involvement in the detoxification process are presented. Images PMID:16662420
NASA Astrophysics Data System (ADS)
Hui, Yu; Rinaldi, Matteo
2013-03-01
This letter presents a miniaturized, fast, and high resolution thermal detector, in which a heat absorbing element and a temperature sensitive microelectromechanical system (MEMS) resonator are perfectly overlapped but separated by a microscale air gap. This unique design guarantees efficient and fast (˜10s μs) heat transfer from the absorbing element to the temperature sensitive device and enables high resolution thermal power detection (˜nW), thanks to the low noise performance of the high quality factor (Q = 2305) MEMS resonant thermal detector. A device prototype was fabricated, and its detection capabilities were experimentally characterized. A thermal power as low as 150 nW was experimentally measured, and a noise equivalent power of 6.5 nW/Hz1/2 was extracted. A device thermal time constant of only 350 μs was measured (smallest ever reported for MEMS resonant thermal detectors), indicating the great potential of the proposed technology for the implementation of ultra-fast and high resolution un-cooled resonant thermal detectors.
Zheng, Lina; Kulkarni, Pramod; Zavvos, Konstantinos; Liang, Huayan; Birch, M. Eileen; Dionysiou, Dionysios D.
2017-01-01
Efficient microconcentration of aerosols to a substrate is essential for effectively coupling the collected particles to microscale optical spectroscopies such as laser-induced or spark microplasma, or micro-Raman or infrared spectroscopies. In this study, we present detailed characterization of a corona-based aerosol microconcentration technique developed previously (Diwakar and Kulkarni, 2012). The method involves two coaxial electrodes separated by a few millimeters, one held at a high electrical potential and the other grounded. The particles are collected on the collection (i.e., ground) electrode from a coaxial aerosol flow in a one-step charge-and-collect scheme using corona discharge and electrical precipitation between the two electrodes. Performance of the corona microconcentration method was determined experimentally by measuring collection efficiency, wall losses, and particle deposition density. An intrinsic spectroscopic sensitivity was experimentally determined for the aerosol microconcentrator. Using this sensitivity, we show that corona-based microconcentration is much superior to alternative methods, including filtration, focused impaction using aerodynamic lens, and spot collection using condensational growth. The method offers unique advantages for compact, hand-held aerosol analytical instrumentation. PMID:28626243
Polarisation vision: overcoming challenges of working with a property of light we barely see
NASA Astrophysics Data System (ADS)
Foster, James J.; Temple, Shelby E.; How, Martin J.; Daly, Ilse M.; Sharkey, Camilla R.; Wilby, David; Roberts, Nicholas W.
2018-04-01
In recent years, the study of polarisation vision in animals has seen numerous breakthroughs, not just in terms of what is known about the function of this sensory ability, but also in the experimental methods by which polarisation can be controlled, presented and measured. Once thought to be limited to only a few animal species, polarisation sensitivity is now known to be widespread across many taxonomic groups, and advances in experimental techniques are, in part, responsible for these discoveries. Nevertheless, its study remains challenging, perhaps because of our own poor sensitivity to the polarisation of light, but equally as a result of the slow spread of new practices and methodological innovations within the field. In this review, we introduce the most important steps in designing and calibrating polarised stimuli, within the broader context of areas of current research and the applications of new techniques to key questions. Our aim is to provide a constructive guide to help researchers, particularly those with no background in the physics of polarisation, to design robust experiments that are free from confounding factors.
Anderson localization of shear waves observed by magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Papazoglou, S.; Klatt, D.; Braun, J.; Sack, I.
2010-07-01
In this letter we present for the first time an experimental investigation of shear wave localization using motion-sensitive magnetic resonance imaging (MRI). Shear wave localization was studied in gel phantoms containing arrays of randomly positioned parallel glass rods. The phantoms were exposed to continuous harmonic vibrations in a frequency range from 25 to 175 Hz, yielding wavelengths on the order of the elastic mean free path, i.e. the Ioffe-Regel criterion of Anderson localization was satisfied. The experimental setup was further chosen such that purely shear horizontal waves were induced to avoid effects due to mode conversion and pressure waves. Analysis of the distribution of shear wave intensity in experiments and simulations revealed a significant deviation from Rayleigh statistics indicating that shear wave energy is localized. This observation is further supported by experiments on weakly scattering samples exhibiting Rayleigh statistics and an analysis of the multifractality of wave functions. Our results suggest that motion-sensitive MRI is a promising tool for studying Anderson localization of time-harmonic shear waves, which are increasingly used in dynamic elastography.
Kerr, Abigail L.; Tennant, Kelly A.
2014-01-01
Mouse models have become increasingly popular in the field of behavioral neuroscience, and specifically in studies of experimental stroke. As models advance, it is important to develop sensitive behavioral measures specific to the mouse. The present protocol describes a skilled motor task for use in mouse models of stroke. The Pasta Matrix Reaching Task functions as a versatile and sensitive behavioral assay that permits experimenters to collect accurate outcome data and manipulate limb use to mimic human clinical phenomena including compensatory strategies (i.e., learned non-use) and focused rehabilitative training. When combined with neuroanatomical tools, this task also permits researchers to explore the mechanisms that support behavioral recovery of function (or lack thereof) following stroke. The task is both simple and affordable to set up and conduct, offering a variety of training and testing options for numerous research questions concerning functional outcome following injury. Though the task has been applied to mouse models of stroke, it may also be beneficial in studies of functional outcome in other upper extremity injury models. PMID:25045916
Supercritical water oxidation of quinazoline: Reaction kinetics and modeling.
Gong, Yanmeng; Guo, Yang; Wang, Shuzhong; Song, Wenhan; Xu, Donghai
2017-03-01
This paper presents a first quantitative kinetic model for supercritical water oxidation (SCWO) of quinazoline that describes the formation and interconversion of intermediates and final products at 673-873 K. The set of 11 reaction pathways for phenol, pyrimidine, naphthalene, NH 3 , etc, involved in the simplified reaction network proved sufficient for fitting the experimental results satisfactorily. We validated the model prediction ability on CO 2 yields at initial quinazoline loading not used in the parameter estimation. Reaction rate analysis and sensitivity analysis indicate that nearly all reactions reach their thermodynamic equilibrium within 300 s. The pyrimidine yielding from quinazoline is the dominant ring-opening pathway and provides a significant contribution to CO 2 formation. Low sensitivity of NH 3 decomposition rate to concentration confirms its refractory nature in SCWO. Nitrogen content in liquid products decreases whereas that in gaseous phase increases as reaction time prolonged. The nitrogen predicted by the model in gaseous phase combined with the experimental nitrogen in liquid products gives an accurate nitrogen balance of conversion process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Integrated amplifying nanowire FET for surface and bulk sensing
NASA Astrophysics Data System (ADS)
Chui, Chi On; Shin, Kyeong-Sik
2011-10-01
For over one decade, numerous research have been performed on field-effect transistor (FET) sensors with a quasi-onedimensional (1D) nanostructure channel demonstrating highly sensitive surface and bulk sensing. The high surface and bulk sensing sensitivity respectively arises from the inherently large surface area-to-volume ratio and tiny channel volume. The generic nanowire FET sensors, however, have limitations such as impractically low output current levels especially near the limit of detection (LOD) that would require downstream remote amplification with an appreciable amount of added noise. We have recently proposed and experimentally demonstrated an innovative amplifying nanowire FET sensor structure that seamlessly integrates therein a sensing nanowire and a nanowire FET amplifier. This novel sensor structure embraces the same geometrical advantage in quasi-1D nanostructure yet it offers unprecedented closeproximity signal amplification with the lowest possible added noise. In this paper, we review the device operating principle and amplification mechanism. We also present the prototype fabrication procedures, and surface and bulk sensing experimental results showing significantly enhanced output current level difference as predicted.
Sequential experimental design based generalised ANOVA
NASA Astrophysics Data System (ADS)
Chakraborty, Souvik; Chowdhury, Rajib
2016-07-01
Over the last decade, surrogate modelling technique has gained wide popularity in the field of uncertainty quantification, optimization, model exploration and sensitivity analysis. This approach relies on experimental design to generate training points and regression/interpolation for generating the surrogate. In this work, it is argued that conventional experimental design may render a surrogate model inefficient. In order to address this issue, this paper presents a novel distribution adaptive sequential experimental design (DA-SED). The proposed DA-SED has been coupled with a variant of generalised analysis of variance (G-ANOVA), developed by representing the component function using the generalised polynomial chaos expansion. Moreover, generalised analytical expressions for calculating the first two statistical moments of the response, which are utilized in predicting the probability of failure, have also been developed. The proposed approach has been utilized in predicting probability of failure of three structural mechanics problems. It is observed that the proposed approach yields accurate and computationally efficient estimate of the failure probability.
Sequential experimental design based generalised ANOVA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Souvik, E-mail: csouvik41@gmail.com; Chowdhury, Rajib, E-mail: rajibfce@iitr.ac.in
Over the last decade, surrogate modelling technique has gained wide popularity in the field of uncertainty quantification, optimization, model exploration and sensitivity analysis. This approach relies on experimental design to generate training points and regression/interpolation for generating the surrogate. In this work, it is argued that conventional experimental design may render a surrogate model inefficient. In order to address this issue, this paper presents a novel distribution adaptive sequential experimental design (DA-SED). The proposed DA-SED has been coupled with a variant of generalised analysis of variance (G-ANOVA), developed by representing the component function using the generalised polynomial chaos expansion. Moreover,more » generalised analytical expressions for calculating the first two statistical moments of the response, which are utilized in predicting the probability of failure, have also been developed. The proposed approach has been utilized in predicting probability of failure of three structural mechanics problems. It is observed that the proposed approach yields accurate and computationally efficient estimate of the failure probability.« less
The Effect of Molecular Orientation to Solid-Solid and Melting Transitions
NASA Astrophysics Data System (ADS)
Yazici, Mustafa; Özgan, Şükrü
The thermodynamics of solid-solid and solid-liquid transitions are investigated with an account of the number of molecular orientation. The variations of the positional and orientational orders with the reduced temperature are studied. It is found out that orientational order parameter is very sensitive to the number of allowed orientation. The reduced transition temperatures, volume changes and entropy changes of the phase transitions and theoretical phase diagrams are obtained. The entropy changes of melting transitions for different numbers of allowed orientation of the present model are compared with the theoretical results and some experimental data. The quantitative predictions of the model are compared with experimental results for plastic crystals and agreement between predictions of the model and the experimental results are approximately good. Also, different numbers of allowed orientation D correspond to different experimental results HI, HBr, H2S for D = 2; HBr, CCl4, HI for D = 4; C2H12 for D = 6; CH4, PH3 for D = 20.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazaretski, E.; Yan, H.; Lauer, K.
2016-08-30
The Hard X-ray Nanoprobe (HXN) beamline at NSLS-II has been designed and constructed to enable imaging experiments with unprecedented spatial resolution and detection sensitivity. The HXN X-ray Microscope is a key instrument for the beamline, providing a suite of experimental capabilities which includes scanning fluorescence, diffraction, differential phase contrast and ptychography utilizing Multilayer Laue Lenses (MLL) and zoneplate (ZP) as nanofocusing optics. In this paper, we present technical requirements for the MLL-based scanning microscope, outline the development concept and present first ~15 x 15 nm 2 spatial resolution x-ray fluorescence images.
NASA Technical Reports Server (NTRS)
Friedl, Randall R. (Editor)
1997-01-01
This first interim assessment of the subsonic assessment (SASS) project attempts to summarize concisely the status of our knowledge concerning the impacts of present and future subsonic aircraft fleets. It also highlights the major areas of scientific uncertainty, through review of existing data bases and model-based sensitivity studies. In view of the need for substantial improvements in both model formulations and experimental databases, this interim assessment cannot provide confident numerical predictions of aviation impacts. However, a number of quantitative estimates are presented, which provide some guidance to policy makers.
NASA Technical Reports Server (NTRS)
Baxa, E. G., Jr.
1974-01-01
A theoretical formulation of differential and composite OMEGA error is presented to establish hypotheses about the functional relationships between various parameters and OMEGA navigational errors. Computer software developed to provide for extensive statistical analysis of the phase data is described. Results from the regression analysis used to conduct parameter sensitivity studies on differential OMEGA error tend to validate the theoretically based hypothesis concerning the relationship between uncorrected differential OMEGA error and receiver separation range and azimuth. Limited results of measurement of receiver repeatability error and line of position measurement error are also presented.
Sensitivity improvements of a resonance-based tactile sensor.
Murayama, Yoshinobu; Lindahl, Olof A
2017-02-01
Resonance-based contact-impedance measurement refers to the application of resonance sensors based on the measurement of the changes in the resonance curve of an ultrasonic resonator in contact with a surface. The advantage of the resonance sensor is that it is very sensitive to small changes in the contact impedance. A sensitive micro tactile sensor (MTS) was developed, which measured the elasticity of soft living tissues at the single-cell level. In the present paper, we studied the method of improving the touch and stiffness sensitivity of the MTS. First, the dependence of touch sensitivity in relation to the resonator length was studied by calculating the sensitivity coefficient at each length ranging from 9 to 40 mm. The highest touch sensitivity was obtained with a 30-mm-long glass needle driven at a resonance frequency of 100 kHz. Next, the numerical calculation of contact impedance showed that the highest stiffness sensitivity was achieved when the driving frequency was 100 kHz and the contact-tip diameter of the MTS was 10 μm. The theoretical model was then confirmed experimentally using a phase-locked-loop-based digital feedback oscillation circuit. It was found that the developed MTS, whose resonant frequency was 97.030 kHz, performed with the highest sensitivity of 53.2 × 10 6 Hz/N at the driving frequency of 97.986 kHz, i.e. the highest sensitivity was achieved at 956 Hz above the resonant frequency.
Shalev, Gil; Rosenwaks, Yossi; Levy, Ilan
2012-01-15
We present experimental results in order to establish a correlation between pH sensitivity of immunologically modified nano-scaled field-effect transistor (NS-ImmunoFET) with their sensing capacity for label-free detection. The NS-ImmunoFETs are fabricated from silicon-on-insulator (SOI) wafers and are fully-depleted with thickness of ~20 nm. The data shows that higher sensitivity to pH entails enhanced sensitivity to analyte detection. This suggests that the mechanism of analyte detection as pure electrostatic perturbation induced by antibody-analyte interaction is over simplified. The fundamental assumption, in existing models for field-effect sensing mechanism assumes that the analyte molecules do not directly interact with the surface but rather stand 'deep' in the solution and away from the dielectric surface. Recent studies clearly provide contradicting evidence demonstrating that antibodies lie down flat on the surface. These observations led us to propose that the proteins that cover the gate area intimately interact with active sites on the surface thus forming a network of interacting sites. Since sensitivity to pH is directly correlated with the amount of amphoteric sites, we witness a direct correlation between sensitivity to pH and analyte detection. The highest and lowest threshold voltage shift for a label-free and specific detection of 6.5 nM IgG were 40 mV and 2.3 mV for NS-ImmunoFETs with pH sensitivity of 35 mV/decade and 15 mV/decade, respectively. Finally, physical modeling of the NS-ImmunoFET is presented and charge of a single IgG protein at pH 6 is calculated. The obtained value is consistent with charge of IgG protein cited in literature. Copyright © 2011 Elsevier B.V. All rights reserved.
Revisiting inconsistency in large pharmacogenomic studies
Safikhani, Zhaleh; Smirnov, Petr; Freeman, Mark; El-Hachem, Nehme; She, Adrian; Rene, Quevedo; Goldenberg, Anna; Birkbak, Nicolai J.; Hatzis, Christos; Shi, Leming; Beck, Andrew H.; Aerts, Hugo J.W.L.; Quackenbush, John; Haibe-Kains, Benjamin
2017-01-01
In 2013, we published a comparative analysis of mutation and gene expression profiles and drug sensitivity measurements for 15 drugs characterized in the 471 cancer cell lines screened in the Genomics of Drug Sensitivity in Cancer (GDSC) and Cancer Cell Line Encyclopedia (CCLE). While we found good concordance in gene expression profiles, there was substantial inconsistency in the drug responses reported by the GDSC and CCLE projects. We received extensive feedback on the comparisons that we performed. This feedback, along with the release of new data, prompted us to revisit our initial analysis. We present a new analysis using these expanded data, where we address the most significant suggestions for improvements on our published analysis — that targeted therapies and broad cytotoxic drugs should have been treated differently in assessing consistency, that consistency of both molecular profiles and drug sensitivity measurements should be compared across cell lines, and that the software analysis tools provided should have been easier to run, particularly as the GDSC and CCLE released additional data. Our re-analysis supports our previous finding that gene expression data are significantly more consistent than drug sensitivity measurements. Using new statistics to assess data consistency allowed identification of two broad effect drugs and three targeted drugs with moderate to good consistency in drug sensitivity data between GDSC and CCLE. For three other targeted drugs, there were not enough sensitive cell lines to assess the consistency of the pharmacological profiles. We found evidence of inconsistencies in pharmacological phenotypes for the remaining eight drugs. Overall, our findings suggest that the drug sensitivity data in GDSC and CCLE continue to present challenges for robust biomarker discovery. This re-analysis provides additional support for the argument that experimental standardization and validation of pharmacogenomic response will be necessary to advance the broad use of large pharmacogenomic screens. PMID:28928933
Greenspan, Joel D.; Slade, Gary D.; Bair, Eric; Dubner, Ronald; Fillingim, Roger B.; Ohrbach, Richard; Knott, Charlie; Mulkey, Flora; Rothwell, Rebecca; Maixner, William
2011-01-01
Many studies report that people with temporomandibular disorders (TMD) are more sensitive to experimental pain stimuli than TMD-free controls. Such differences in sensitivity are observed in remote body sites as well as in the orofacial region, suggesting a generalized upregulation of nociceptive processing in TMD cases. This large case-control study of 185 adults with TMD and 1,633 TMD-free controls measured sensitivity to painful pressure, mechanical cutaneous, and heat stimuli, using multiple testing protocols. Based on an unprecedented 36 experimental pain measures, 28 showed statistically significantly greater pain sensitivity in TMD cases than controls. The largest effects were seen for pressure pain thresholds at multiple body sites and cutaneous mechanical pain threshold. The other mechanical cutaneous pain measures and many of the heat pain measures showed significant differences, but with lesser effect sizes. Principal component analysis (PCA) of the pain measures derived from 1,633 controls identified five components labeled: (1) heat pain ratings, (2) heat pain aftersensations and tolerance, (3) mechanical cutaneous pain sensitivity, (4) pressure pain thresholds, and (5) heat pain temporal summation. These results demonstrate that, compared to TMD-free controls, chronic TMD cases are more sensitive to many experimental noxious stimuli at extra-cranial body sites, and provides for the first time the ability to directly compare the case-control effect sizes of a wide range of pain sensitivity measures. PMID:22074753
Attention-based long-lasting sensitization and suppression of colors.
Tseng, Chia-Huei; Vidnyanszky, Zoltan; Papathomas, Thomas; Sperling, George
2010-02-22
In contrast to the short-duration and quick reversibility of attention, a long-term sensitization to color based on protracted attention in a visual search task was reported by Tseng, Gobell, and Sperling (2004). When subjects were trained for a few hours to search for a red object among colored distracters, sensitivity to red was increased for weeks. This sensitization was quantified using ambiguous motion displays containing isoluminant red-green and texture-contrast gratings, in which the perceived motion-direction depended both on the attended color and on the relative red-green saturation. Such long-term effects could result from either sensitization of the attended color, or suppression of unattended colors, or a combination of the two. Here we unconfound these effects by eliminating one of the paired colors of the motion display from the search task. The other paired color in the motion display can then be either a target or a distracter in the search task. Thereby, we separately measure the effect of attention on sensitizing the target color or suppressing distracter colors. The results indicate that only sensitization of the target color in the search task is statistically significant for the present experimental conditions. We conclude that selective attention to a color in our visual search task caused long-term sensitization to the attended color but not significant long-term suppression of the unattended color. Copyright 2009 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wilkie, W. Keats; Langston, Chester W.; Mirick, Paul H.; Singleton, Jeffrey D.; Wilbur, Matthew L.; Yeager, William T., Jr.
1991-01-01
The sensitivity of blade tracking in hover to variations in root pitch was examined for two rotor configurations. Tests were conducted using a four bladed articulated rotor mounted on the NASA-Army aeroelastic rotor experimental system (ARES). Two rotor configurations were tested: one consisting of a blade set with flexible fiberglass spars and one with stiffer (by a factor of five in flapwise and torsional stiffnesses) aluminum spars. Both blade sets were identical in planform and airfoil distribution and were untwisted. The two configurations were ballasted to the same Lock number so that a direct comparison of the tracking sensitivity to a gross change in blade stiffness could be made. Experimental results show no large differences between the two sets of blades in the sensitivity of the blade tracking to root pitch adjustments. However, a measurable reduction in intrack coning of the fiberglass spar blades with respect to the aluminum blades is noted at higher rotor thrust conditions.
Keenan, Kevin G; Valero-Cuevas, Francisco J
2007-09-01
Computational models of motor-unit populations are the objective implementations of the hypothesized mechanisms by which neural and muscle properties give rise to electromyograms (EMGs) and force. However, the variability/uncertainty of the parameters used in these models--and how they affect predictions--confounds assessing these hypothesized mechanisms. We perform a large-scale computational sensitivity analysis on the state-of-the-art computational model of surface EMG, force, and force variability by combining a comprehensive review of published experimental data with Monte Carlo simulations. To exhaustively explore model performance and robustness, we ran numerous iterative simulations each using a random set of values for nine commonly measured motor neuron and muscle parameters. Parameter values were sampled across their reported experimental ranges. Convergence after 439 simulations found that only 3 simulations met our two fitness criteria: approximating the well-established experimental relations for the scaling of EMG amplitude and force variability with mean force. An additional 424 simulations preferentially sampling the neighborhood of those 3 valid simulations converged to reveal 65 additional sets of parameter values for which the model predictions approximate the experimentally known relations. We find the model is not sensitive to muscle properties but very sensitive to several motor neuron properties--especially peak discharge rates and recruitment ranges. Therefore to advance our understanding of EMG and muscle force, it is critical to evaluate the hypothesized neural mechanisms as implemented in today's state-of-the-art models of motor unit function. We discuss experimental and analytical avenues to do so as well as new features that may be added in future implementations of motor-unit models to improve their experimental validity.
NASA Astrophysics Data System (ADS)
Weiß-Borkowski, Nathalie; Lian, Junhe; Camberg, Alan; Tröster, Thomas; Münstermann, Sebastian; Bleck, Wolfgang; Gese, Helmut; Richter, Helmut
2018-05-01
Determination of forming limit curves (FLC) to describe the multi-axial forming behaviour is possible via either experimental measurements or theoretical calculations. In case of theoretical determination, different models are available and some of them consider the influence of strain rate in the quasi-static and dynamic strain rate regime. Consideration of the strain rate effect is necessary as many material characteristics such as yield strength and failure strain are affected by loading speed. In addition, the start of instability and necking depends not only on the strain hardening coefficient but also on the strain rate sensitivity parameter. Therefore, the strain rate dependency of materials for both plasticity and the failure behaviour is taken into account in crash simulations for strain rates up to 1000 s-1 and FLC can be used for the description of the material's instability behaviour at multi-axial loading. In this context, due to the strain rate dependency of the material behaviour, an extrapolation of the quasi-static FLC to dynamic loading condition is not reliable. Therefore, experimental high-speed Nakajima tests or theoretical models shall be used to determine the FLC at high strain rates. In this study, two theoretical models for determination of FLC at high strain rates and results of experimental high-speed Nakajima tests for a DP600 are presented. One of the theoretical models is the numerical algorithm CRACH as part of the modular material and failure model MF GenYld+CrachFEM 4.2, which is based on an initial imperfection. Furthermore, the extended modified maximum force criterion considering the strain rate effect is also used to predict the FLC. These two models are calibrated by the quasi-static and dynamic uniaxial tensile tests and bulge tests. The predictions for the quasi-static and dynamic FLC by both models are presented and compared with the experimental results.
NASA Astrophysics Data System (ADS)
Tsiokos, Dimitris M.; Dabos, George; Ketzaki, Dimitra; Weeber, Jean-Claude; Markey, Laurent; Dereux, Alain; Giesecke, Anna Lena; Porschatis, Caroline; Chmielak, Bartos; Wahlbrink, Thorsten; Rochracher, Karl; Pleros, Nikos
2017-05-01
Silicon photonics meet most fabrication requirements of standard CMOS process lines encompassing the photonics-electronics consolidation vision. Despite this remarkable progress, further miniaturization of PICs for common integration with electronics and for increasing PIC functional density is bounded by the inherent diffraction limit of light imposed by optical waveguides. Instead, Surface Plasmon Polariton (SPP) waveguides can guide light at sub-wavelength scales at the metal surface providing unique light-matter interaction properties, exploiting at the same time their metallic nature to naturally integrate with electronics in high-performance ASPICs. In this article, we demonstrate the main goals of the recently introduced H2020 project PlasmoFab towards addressing the ever increasing needs for low energy, small size and high performance mass manufactured PICs by developing a revolutionary yet CMOS-compatible fabrication platform for seamless co-integration of plasmonics with photonic and supporting electronic. We demonstrate recent advances on the hosting SiN photonic hosting platform reporting on low-loss passive SiN waveguide and Grating Coupler circuits for both the TM and TE polarization states. We also present experimental results of plasmonic gold thin-film and hybrid slot waveguide configurations that can allow for high-sensitivity sensing, providing also the ongoing activities towards replacing gold with Cu, Al or TiN metal in order to yield the same functionality over a CMOS metallic structure. Finally, the first experimental results on the co-integrated SiN+plasmonic platform are demonstrated, concluding to an initial theoretical performance analysis of the CMOS plasmo-photonic biosensor that has the potential to allow for sensitivities beyond 150000nm/RIU.
Serra, Montserrat; Brazís, Pilar; Fondati, Alessandra; Puigdemont, Anna
2006-11-01
To assess binding of IgE to native, whole hydrolyzed, and separated hydrolyzed fractions of soy protein in serum obtained from dogs with experimentally induced soy protein hypersensitivity. 8 naïve Beagles (6 experimentally sensitized to native soy protein and 2 control dogs). 6 dogs were sensitized against soy protein by administration of allergens during a 90-day period. After the sensitization protocol was completed, serum concentrations of soy-specific IgE were measured and intradermal skin tests were performed in all 6 dogs to confirm that the dogs were sensitized against soy protein. Serum samples from each sensitized and control dog underwent western blot analysis to assess the molecular mass band pattern of the different allergenic soy fractions and evaluate reactivities to native and hydrolyzed soy protein. In sera from sensitized dogs, a characteristic band pattern with 2 major bands (approx 75 and 50 kd) and 2 minor bands (approx 31 and 20 kd) was detected, whereas only a diffuse band pattern associated with whole hydrolyzed soy protein was detected in the most reactive dog. Reactivity was evident only for the higher molecular mass peptide fraction. In control dogs, no IgE reaction to native or hydrolyzed soy protein was detected. Data suggest that the binding of soy-specific IgE to the hydrolyzed soy protein used in the study was significantly reduced, compared with binding of soy-specific IgE to the native soy protein, in dogs with experimentally induced soy hypersensitivity.
Radiation noise in a high sensitivity star sensor
NASA Technical Reports Server (NTRS)
Parkinson, J. B.; Gordon, E.
1972-01-01
An extremely accurate attitude determination was developed for space applications. This system uses a high sensitivity star sensor in which the photomultiplier tube is subject to noise generated by space radiations. The space radiation induced noise arises from trapped electrons, solar protons and other ionizing radiations, as well as from dim star background. The solar activity and hence the electron and proton environments are predicted through the end of the twentieth century. The available data for the response of the phototube to proton, electron, gamma ray, and bremsstrahlung radiations are reviewed and new experimental data is presented. A simulation was developed which represents the characteristics of the effect of radiations on the star sensor, including the non-stationarity of the backgrounds.
In-Pile Sub-Miniature Fission Chambers Testing in BR2
NASA Astrophysics Data System (ADS)
Vermeeren, L.; Wéber, M.; Blandin, Ch.; Breaud, S.
2003-06-01
Three innovative sub-miniature fission chambers (SMFC), designed and manufactured at the Nuclear Measurement Systems Laboratory (LSMN) of CEA/Cadarache, were extensively tested in the BR2 research reactor at SCK•CEN, Mol. We present the experimental results for the (thermal) neutron sensitivity, the gamma-induced signal, the signal due to activation, the current picked up by the signal cable, the global current/voltage characteristics and the long term behaviour up to a thermal neutron fluence of 2.7·1021 n/cm2. We also compare the data with results from calculations with our FCD computer code. The onset of the saturation domain is well predicted by FCD; the neutron sensitivities can be accounted for perfectly after a refinement of the FCD model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Bhisham N.; Naragani, Diwakar; Nguyen, Ba Nghiep
We present a detailed methodology for experimental measurement of fiber orientation distribution (FOD) in injection-molded discontinuous fiber composites using the method of ellipses on 2D cross sections. Best practices to avoid biases occurring during surface preparation and optical imaging of carbon-fiber-reinforced thermoplastics are discussed. A marker-based watershed transform routine for efficient image segmentation and the separation of touching fiber ellipses is developed. The sensitivity of the averaged orientation tensor to the image sample size is studied for the case of long-fiber thermoplastics. A Mori-Tanaka implementation of the Eshelby model is then employed to quantify the sensitivity of elastic stiffness predictionsmore » to biases in the FOD measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Bhisham N.; Naragani, Diwakar; Nguyen, Ba Nghiep
Here, we present a detailed methodology for experimental measurement of fiber orientation distribution in injection-molded discontinuous fiber composites using the method of ellipses on two-dimensional cross sections. Best practices to avoid biases occurring during surface preparation and optical imaging of carbon-fiber-reinforced thermoplastics are discussed. We developed a marker-based watershed transform routine for efficient image segmentation and the separation of touching fiber ellipses. The sensitivity of the averaged orientation tensor to the image sample size is studied for the case of long-fiber thermoplastics. A Mori–Tanaka implementation of the Eshelby model is then employed to quantify the sensitivity of elastic stiffness predictionsmore » to biases in the fiber orientation distribution measurements.« less
Villiger, Martin; Zhang, Ellen Ziyi; Nadkarni, Seemantini K.; Oh, Wang-Yuhl; Vakoc, Benjamin J.; Bouma, Brett E.
2013-01-01
Polarization mode dispersion (PMD) has been recognized as a significant barrier to sensitive and reproducible birefringence measurements with fiber-based, polarization-sensitive optical coherence tomography systems. Here, we present a signal processing strategy that reconstructs the local retardation robustly in the presence of system PMD. The algorithm uses a spectral binning approach to limit the detrimental impact of system PMD and benefits from the final averaging of the PMD-corrected retardation vectors of the spectral bins. The algorithm was validated with numerical simulations and experimental measurements of a rubber phantom. When applied to the imaging of human cadaveric coronary arteries, the algorithm was found to yield a substantial improvement in the reconstructed birefringence maps. PMID:23938487
Sharma, Bhisham N.; Naragani, Diwakar; Nguyen, Ba Nghiep; ...
2017-09-28
Here, we present a detailed methodology for experimental measurement of fiber orientation distribution in injection-molded discontinuous fiber composites using the method of ellipses on two-dimensional cross sections. Best practices to avoid biases occurring during surface preparation and optical imaging of carbon-fiber-reinforced thermoplastics are discussed. We developed a marker-based watershed transform routine for efficient image segmentation and the separation of touching fiber ellipses. The sensitivity of the averaged orientation tensor to the image sample size is studied for the case of long-fiber thermoplastics. A Mori–Tanaka implementation of the Eshelby model is then employed to quantify the sensitivity of elastic stiffness predictionsmore » to biases in the fiber orientation distribution measurements.« less
Sergé, Arnauld; Bernard, Anne-Marie; Phélipot, Marie-Claire; Bertaux, Nicolas; Fallet, Mathieu; Grenot, Pierre; Marguet, Didier; He, Hai-Tao; Hamon, Yannick
2013-01-01
We introduce a series of experimental procedures enabling sensitive calcium monitoring in T cell populations by confocal video-microscopy. Tracking and post-acquisition analysis was performed using Methods for Automated and Accurate Analysis of Cell Signals (MAAACS), a fully customized program that associates a high throughput tracking algorithm, an intuitive reconnection routine and a statistical platform to provide, at a glance, the calcium barcode of a population of individual T-cells. Combined with a sensitive calcium probe, this method allowed us to unravel the heterogeneity in shape and intensity of the calcium response in T cell populations and especially in naive T cells, which display intracellular calcium oscillations upon stimulation by antigen presenting cells. PMID:24086124
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brice, S. J.; Cooper, R. L.; DeJongh, F.
2014-04-03
We present an experimental method for measuring the process of coherent elastic neutrino-nucleus scattering (CENNS). This method uses a detector situated transverse to a high-energy neutrino beam production target. This detector would be sensitive to the low-energy neutrinos arising from decay-at-rest pions in the target. We discuss the physics motivation for making this measurement and outline the predicted backgrounds and sensitivities using this approach. We report a measurement of neutron backgrounds as found in an off-axis surface location of the Fermilab Booster Neutrino Beam (BNB) target. The results indicate that the Fermilab BNB target is a favorable location for amore » CENNS experiment.« less
Framing sound: Using expectations to reduce environmental noise annoyance.
Crichton, Fiona; Dodd, George; Schmid, Gian; Petrie, Keith J
2015-10-01
Annoyance reactions to environmental noise, such as wind turbine sound, have public health implications given associations between annoyance and symptoms related to psychological distress. In the case of wind farms, factors contributing to noise annoyance have been theorised to include wind turbine sound characteristics, the noise sensitivity of residents, and contextual aspects, such as receiving information creating negative expectations about sound exposure. The experimental aim was to assess whether receiving positive or negative expectations about wind farm sound would differentially influence annoyance reactions during exposure to wind farm sound, and also influence associations between perceived noise sensitivity and noise annoyance. Sixty volunteers were randomly assigned to receive either negative or positive expectations about wind farm sound. Participants in the negative expectation group viewed a presentation which incorporated internet material indicating that exposure to wind turbine sound, particularly infrasound, might present a health risk. Positive expectation participants viewed a DVD which framed wind farm sound positively and included internet information about the health benefits of infrasound exposure. Participants were then simultaneously exposed to sub-audible infrasound and audible wind farm sound during two 7 min exposure sessions, during which they assessed their experience of annoyance. Positive expectation participants were significantly less annoyed than negative expectation participants, while noise sensitivity only predicted annoyance in the negative group. Findings suggest accessing negative information about sound is likely to trigger annoyance, particularly in noise sensitive people and, importantly, portraying sound positively may reduce annoyance reactions, even in noise sensitive individuals. Copyright © 2015 Elsevier Inc. All rights reserved.
Vibrational Spectroscopy on Photoexcited Dye-Sensitized Films via Pump-Degenerate Four-Wave Mixing.
Abraham, Baxter; Fan, Hao; Galoppini, Elena; Gundlach, Lars
2018-03-01
Molecular sensitization of semiconductor films is an important technology for energy and environmental applications including solar energy conversion, photocatalytic hydrogen production, and water purification. Dye-sensitized films are also scientifically complex and interesting systems with a long history of research. In most applications, photoinduced heterogeneous electron transfer (HET) at the molecule/semiconductor interface is of critical importance, and while great progress has been made in understanding HET, many open questions remain. Of particular interest is the role of combined electronic and vibrational effects and coherence of the dye during HET. The ultrafast nature of the process, the rapid intramolecular vibrational energy redistribution, and vibrational cooling present complications in the study of vibronic coupling in HET. We present the application of a time domain vibrational spectroscopy-pump-degenerate four-wave mixing (pump-DFWM)-to dye-sensitized solid-state semiconductor films. Pump-DFWM can measure Raman-active vibrational modes that are triggered by excitation of the sample with an actinic pump pulse. Modifications to the instrument for solid-state samples and its application to an anatase TiO 2 film sensitized by a Zn-porphyrin dye are discussed. We show an effective combination of experimental techniques to overcome typical challenges in measuring solid-state samples with laser spectroscopy and observe molecular vibrations following HET in a picosecond time window. The cation spectrum of the dye shows modes that can be assigned to the linker group and a mode that is localized on the Zn-phorphyrin chromophore and that is connected to photoexcitation.
Reward Sensitivity for a Palatable Food Reward Peaks During Pubertal Developmental in Rats
Friemel, Chris M.; Spanagel, Rainer; Schneider, Miriam
2010-01-01
Puberty is a critical period for the initiation of drug use and abuse. Because early drug use onset often accounts for a more severe progression of addiction, it is of importance to understand the underlying mechanisms and neurodevelopmental changes during puberty that are contributing to enhanced reward processing in teenagers. The present study investigated the progression of reward sensitivity toward a natural food reward over the whole course of adolescence in male rats (postnatal days 30–90) by monitoring consummatory, motivational behavior and neurobiological correlates of reward. Using a limited-free intake paradigm, consumption of sweetened condensed milk (SCM) was measured repeatedly in adolescent and adult rats. Additionally, early- and mid-pubertal animals were tested in Progressive Ratio responding for SCM and c-fos protein expression in reward-associated brain structures was examined after odor conditioning for SCM. We found a transient increase in SCM consumption and motivational incentive for SCM during puberty. This increased reward sensitivity was most pronounced around mid-puberty. The behavioral findings are paralleled by enhanced c-fos staining in reward-related structures revealing an intensified neuronal response after reward-cue presentation, distinctive for pubertal animals. Taken together, these data indicate an increase in reward sensitivity during adolescence accompanied by enhanced responsiveness of reward-associated brain structures to incentive stimuli, and it seems that both is strongly pronounced around mid-puberty. Therefore, higher reward sensitivity during pubertal maturation might contribute to the enhanced vulnerability of teenagers for the initiation of experimental drug use. PMID:20700386
Mohammed, Monzoorul Haque; Ghosh, Tarini Shankar; Chadaram, Sudha; Mande, Sharmila S
2011-11-30
Obtaining accurate estimates of microbial diversity using rDNA profiling is the first step in most metagenomics projects. Consequently, most metagenomic projects spend considerable amounts of time, money and manpower for experimentally cloning, amplifying and sequencing the rDNA content in a metagenomic sample. In the second step, the entire genomic content of the metagenome is extracted, sequenced and analyzed. Since DNA sequences obtained in this second step also contain rDNA fragments, rapid in silico identification of these rDNA fragments would drastically reduce the cost, time and effort of current metagenomic projects by entirely bypassing the experimental steps of primer based rDNA amplification, cloning and sequencing. In this study, we present an algorithm called i-rDNA that can facilitate the rapid detection of 16S rDNA fragments from amongst millions of sequences in metagenomic data sets with high detection sensitivity. Performance evaluation with data sets/database variants simulating typical metagenomic scenarios indicates the significantly high detection sensitivity of i-rDNA. Moreover, i-rDNA can process a million sequences in less than an hour on a simple desktop with modest hardware specifications. In addition to the speed of execution, high sensitivity and low false positive rate, the utility of the algorithmic approach discussed in this paper is immense given that it would help in bypassing the entire experimental step of primer-based rDNA amplification, cloning and sequencing. Application of this algorithmic approach would thus drastically reduce the cost, time and human efforts invested in all metagenomic projects. A web-server for the i-rDNA algorithm is available at http://metagenomics.atc.tcs.com/i-rDNA/
Space-charge-sustained microbunch structure in the Los Alamos Proton Storage Ring
NASA Astrophysics Data System (ADS)
Cousineau, S.; Danilov, V.; Holmes, J.; Macek, R.
2004-09-01
We present experimental data from the Los Alamos Proton Storage Ring (PSR) showing long-lived linac microbunch structure during beam storage with no rf bunching. Analysis of the experimental data and particle-in-cell simulations of the experiments indicate that space charge, coupled with energy spread effects, is responsible for the sustained microbunch structure. The simulated longitudinal phase space of the beam reveals a well-defined separatrix in the phase space between linac microbunches, with particles executing unbounded motion outside of the separatrix. We show that the longitudinal phase space of the beam was near steady state during the PSR experiments, such that the separatrix persisted for long periods of time. Our simulations indicate that the steady state is very sensitive to the experimental conditions. Finally, we solve the steady-state problem in an analytic, self-consistent fashion for a set of periodic longitudinal space-charge potentials.
Experimental results on the ω- and η'-nucleus potential - on the way to mesic states
NASA Astrophysics Data System (ADS)
Nanova, Mariana
2015-06-01
Different experimental approaches to determine the meson-nucleus optical potential are discussed. The experiments have been performed with the Crystal Barrel/TAPS detector system at the ELSA accelerator in Bonn and the Crystal Ball/TAPS at the MAMI accelerator in Mainz. Experimental results about the real and imaginary part of the η'- and ω-nucleus optical potential are presented. The imaginary part of the meson-nucleus optical potential is determined from the in-medium width of the meson by the measurement of the transparency ratio. Information on the real part of the optical potential is deduced from measurements of the excitation function and momentum distribution which are sensitive to the sign and depth of the potential. The results are discussed and compared to theoretical predictions. The data for both mesons are consistent with a weakly attractive potential. The formation and population of ω-nucleus and η'-nucleus bound states is additionally discussed.
Hydrostatic Pressure Sensing with High Birefringence Photonic Crystal Fibers
Fávero, Fernando C.; Quintero, Sully M. M.; Martelli, Cicero; Braga, Arthur M.B.; Silva, Vinícius V.; Carvalho, Isabel C. S.; Llerena, Roberth W. A.; Valente, Luiz C. G.
2010-01-01
The effect of hydrostatic pressure on the waveguiding properties of high birefringence photonic crystal fibers (HiBi PCF) is evaluated both numerically and experimentally. A fiber design presenting form birefringence induced by two enlarged holes in the innermost ring defining the fiber core is investigated. Numerical results show that modal sensitivity to the applied pressure depends on the diameters of the holes, and can be tailored by independently varying the sizes of the large or small holes. Numerical and experimental results are compared showing excellent agreement. A hydrostatic pressure sensor is proposed and demonstrated using an in-fiber modal interferometer where the two orthogonally polarized modes of a HiBi PCF generate fringes over the optical spectrum of a broad band source. From the analysis of experimental results, it is concluded that, in principle, an operating limit of 92 MPa in pressure could be achieved with 0.0003% of full scale resolution. PMID:22163435
NASA Astrophysics Data System (ADS)
Liang, Jing; Yu, Jian-xing; Yu, Yang; Lam, W.; Zhao, Yi-yu; Duan, Jing-hui
2016-06-01
Energy transfer ratio is the basic-factor affecting the level of pipe damage during the impact between dropped object and submarine pipe. For the purpose of studying energy transfer and damage mechanism of submarine pipe impacted by dropped objects, series of experiments are designed and carried out. The effective yield strength is deduced to make the quasi-static analysis more reliable, and the normal distribution of energy transfer ratio caused by lateral impact on pipes is presented by statistic analysis of experimental results based on the effective yield strength, which provides experimental and theoretical basis for the risk analysis of submarine pipe system impacted by dropped objects. Failure strains of pipe material are confirmed by comparing experimental results with finite element simulation. In addition, impact contact area and impact time are proved to be the major influence factors of energy transfer by sensitivity analysis of the finite element simulation.
Experimental Observations and Theoretical Modeling of VLF Scattering During LEP Events
NASA Astrophysics Data System (ADS)
Mitchell, M. F.; Moore, R. C.
2012-12-01
Recent experimental observations of very low frequency (VLF) scattering during lightning-induced election precipitation (LEP) events are presented. A spread spectrum analysis technique is applied to these observations, demonstrating a significant dependence on frequency. For LEP events, the scattered field amplitude and phase both exhibit strong frequency dependence, as do the event onset delays (relative to the causative lightning flash) and the event onset durations. The experimental observations are compared with the predictions of an Earth-ionosphere waveguide propagation and scattering model. The Long-Wave Propagation Capability (LWPC) code is used to demonstrate that the scattered field amplitude and phase depend sensitively on the electrical properties of the scattering body and the ionosphere between the scatterer and the receiver. The observed frequency-dependent onset times and durations, on the other hand, are attributed to the scattering source characteristics. These measurements can also be used to study radiation belt dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tarasova, E. A.; Obolenskaya, E. S., E-mail: obolensk@rf.unn.ru; Hananova, A. V.
The sensitivity of classical n{sup +}/n{sup –} GaAs and AlGaN/GaN structures with a 2D electron gas (HEMT) and field-effect transistors based on these structures to γ-neutron exposure is studied. The levels of their radiation hardness were determined. A method for experimental study of the structures on the basis of a differential analysis of their current–voltage characteristics is developed. This method makes it possible to determine the structure of the layers in which radiation-induced defects accumulate. A procedure taking into account changes in the plate area of the experimentally measured barrier-contact capacitance associated with the emergence of clusters of radiation-induced defectsmore » that form dielectric inclusions in the 2D-electron-gas layer is presented for the first time.« less
NASA Astrophysics Data System (ADS)
Sandoval-Santana, J. C.; Ibarra-Sierra, V. G.; Azaizia, S.; Carrère, H.; Bakaleinikov, L. A.; Kalevich, V. K.; Ivchenko, E. L.; Marie, X.; Amand, T.; Balocchi, A.; Kunold, A.
2018-03-01
We propose an experimental procedure to track the evolution of electronic and nuclear spins in Ga2+ centers in GaAsN dilute semiconductors. The method is based on a pump-probe scheme that enables to monitor the time evolution of the three components of the electronic and nuclear spin variables. In contrast to other characterization methods, as nuclear magnetic resonance, this one only needs moderate magnetic fields (B≈ 10 mT), and does not require microwave irradiation. Specifically, we carry out a series of tests for different experimental conditions in order to optimize the procedure for maximum sensitivity in the measurement of the circular degree of polarization. Based on previous experimental results and the theoretical calculations presented here, we estimate that the method could yield a time resolution of about 10ps.
Length matters: Improved high field EEG-fMRI recordings using shorter EEG cables.
Assecondi, Sara; Lavallee, Christina; Ferrari, Paolo; Jovicich, Jorge
2016-08-30
The use of concurrent EEG-fMRI recordings has increased in recent years, allowing new avenues of medical and cognitive neuroscience research; however, currently used setups present problems with data quality and reproducibility. We propose a compact experimental setup for concurrent EEG-fMRI at 4T and compare it to a more standard reference setup. The compact setup uses short EEG cables connecting to the amplifiers, which are placed right at the back of the head RF coil on a form-fitting extension force-locked to the patient MR bed. We compare the two setups in terms of sensitivity to MR-room environmental noise, interferences between measuring devices (EEG or fMRI), and sensitivity to functional responses in a visual stimulation paradigm. The compact setup reduces the system sensitivity to both external noise and MR-induced artefacts by at least 60%, with negligible EEG noise induced from the mechanical vibrations of the cryogenic cooling compression pump. The compact setup improved EEG data quality and the overall performance of MR-artifact correction techniques. Both setups were similar in terms of the fMRI data, with higher reproducibility for cable placement within the scanner in the compact setup. This improved compact setup may be relevant to MR laboratories interested in reducing the sensitivity of their EEG-fMRI experimental setup to external noise sources, setting up an EEG-fMRI workplace for the first time, or for creating a more reproducible configuration of equipment and cables. Implications for safety and ergonomics are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Central sensitization: Implications for the diagnosis and treatment of pain
Woolf, Clifford J
2010-01-01
Nociceptor inputs can trigger a prolonged but reversible increase in the excitability and synaptic efficacy of neurons in central nociceptive pathways, the phenomenon of central sensitization. Central sensitization manifests as pain hypersensitivity, particularly dynamic tactile allodynia, secondary punctate or pressure hyperalgesia, aftersensations, and enhanced temporal summation. It can be readily and rapidly elicited in human volunteers by diverse experimental noxious conditioning stimuli to skin, muscles or viscera, and in addition to producing pain hypersensitivity, results in secondary changes in brain activity that can be detected by electrophysiological or imaging techniques. Studies in clinical cohorts reveal changes in pain sensitivity that have been interpreted as revealing an important contribution of central sensitization to the pain phenotype in patients with fibromyalgia, osteoarthritis, musculoskeletal disorders with generalized pain hypersensitivity, headache, temporomandibular joint disorders, dental pain, neuropathic pain, visceral pain hypersensitivity disorders and postsurgical pain. The comorbidity of those pain hypersensitivity syndromes that present in the absence of inflammation or a neural lesion, their similar pattern of clinical presentation and response to centrally acting analgesics, may reflect a commonality of central sensitization to their pathophysiology. An important question that still needs to be determined is whether there are individuals with a higher inherited propensity for developing central sensitization than others, and if so, whether this conveys an increased risk both of developing conditions with pain hypersensitivity, and their chronification. Diagnostic criteria to establish the presence of central sensitization in patients will greatly assist the phenotyping of patients for choosing treatments that produce analgesia by normalizing hyperexcitable central neural activity. We have certainly come a long way since the first discovery of activity-dependent synaptic plasticity in the spinal cord and the revelation that it occurs and produces pain hypersensitivity in patients. Nevertheless, discovering the genetic and environmental contributors to and objective biomarkers of central sensitization will be highly beneficial, as will additional treatment options to prevent or reduce this prevalent and promiscuous form of pain plasticity. PMID:20961685
Myopathic Alterations in Extraocular Muscle of Rats Subchronically Fed Pyridostigmine Bromide
1990-01-01
myasthenia gravis and could be used by U.S. mil- sis. Ultrastructurally, in muscles such as diaphragm, itary personnel and their allies as part of a...cleft were common features. This last feature has changes at the NMJ of diaphragm and soleus mus- been reported in human myasthenia gravis in the cles...greater sensitivity to PB, VA (1976). The motor end plate in myasthenia gravis as severe morphologic alterations are still present and in experimental
Three-Signal Method for Accurate Measurements of Depolarization Ratio with Lidar
NASA Technical Reports Server (NTRS)
Reichardt, Jens; Baumgart, Rudolf; McGee, Thomsa J.
2003-01-01
A method is presented that permits the determination of atmospheric depolarization-ratio profiles from three elastic-backscatter lidar signals with different sensitivity to the state of polarization of the backscattered light. The three-signal method is insensitive to experimental errors and does not require calibration of the measurement, which could cause large systematic uncertainties of the results, as is the case in the lidar technique conventionally used for the observation of depolarization ratios.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael; Abel, Joshua; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.
NASA Technical Reports Server (NTRS)
Woronowicz, Michael S.; Abel, Joshua C.; Autrey, David; Blackmon, Rebecca; Bond, Tim; Brown, Martin; Buffington, Jesse; Cheng, Edward; DeLatte, Danielle; Garcia, Kelvin;
2014-01-01
The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.
NASA Astrophysics Data System (ADS)
Seah, M. P.; Gilmore, I. S.
2006-05-01
An analysis is provided of the x-ray photoelectron spectroscopy (XPS) intensities measured in the National Physical Laboratory (NPL) XPS database for 46 solid elements. This present analysis does not change our previous conclusions concerning the excellent correlation between experimental intensities, following deconvolving the spectra with angle-averaged reflection electron energy loss data, and the theoretical intensities involving the dipole approximation using Scofield’s cross sections. Here, more recent calculations for cross sections by Trzhaskovskaya involving quadrupole terms are evaluated and it is shown that their cross sections diverge from the experimental database results by up to a factor of 5. The quadrupole angular terms lead to small corrections that are close to our measurement limit but do appear to be supported in the present analysis. Measurements of the extent of shake-up for the 46 elements broadly agree with the calculations of Yarzhemsky but not in detail. The predicted constancy in the shake-up contribution by Yarzhemsky implies that the use of the Shirley background will lead to a peak area that is a constant fraction of the true peak area including the shake-up intensities. However, the measured variability of the shake-up contribution makes the Shirley background invalid for quantification except for situations where the sensitivity factors are from reference samples similar to those being analyzed.
Dynamic response of active twist rotor blades
NASA Astrophysics Data System (ADS)
Cesnik, Carlos E. S.; Shin, Sang Joon; Wilbur, Matthew L.
2001-02-01
Dynamic characteristics of active twist rotor (ATR) blades are investigated analytically and experimentally in this paper. The ATR system is intended for vibration and potentially for noise reductions in helicopters through individual blade control. An aeroelastic model is developed to identify frequency response characteristics of the ATR blade with integral, generally anisotropic, strain actuators embedded in its composite construction. An ATR prototype blade was designed and manufactured to experimentally study the vibration reduction capabilities of such systems. Several bench and hover tests were conducted and those results are presented and discussed here. Selected results on sensitivity of the ATR system to collective setting (i.e. blade loading), blade rpm (i.e. centrifugal force and blade station velocity), and media density (i.e. altitude) are presented. They indicated that the twist actuation authority of the ATR blade is independent of the collective setting up to approximately 10P, and dependent on rotational speed and altitude near the torsional resonance frequency due to its dependency on the aerodynamic damping. The proposed model captures very well the physics and sensitivities to selected test parameters of the ATR system. The numerical result of the blade torsional loads show an average error of 20% in magnitude and virtually no difference in phase for the blade frequency response. Overall, the active blade model is in very good agreement with the experiments and can be used to analyze and design future active helicopter blade systems.
Dynamic curvature sensing employing ionic-polymer-metal composite sensors
NASA Astrophysics Data System (ADS)
Bahramzadeh, Yousef; Shahinpoor, Mohsen
2011-09-01
A dynamic curvature sensor is presented based on ionic-polymer-metal composite (IPMC) for curvature monitoring of deployable/inflatable dynamic space structures. Monitoring the curvature variation is of high importance in various engineering structures including shape monitoring of deployable/inflatable space structures in which the structural boundaries undergo a dynamic deployment process. The high sensitivity of IPMCs to the applied deformations as well as its flexibility make IPMCs a promising candidate for sensing of dynamic curvature changes. Herein, we explore the dynamic response of an IPMC sensor strip with respect to controlled curvature deformations subjected to different forms of input functions. Using a specially designed experimental setup, the voltage recovery effect, phase delay, and rate dependency of the output voltage signal of an IPMC curvature sensor are analyzed. Experimental results show that the IPMC sensor maintains the linearity, sensitivity, and repeatability required for curvature sensing. Besides, in order to describe the dynamic phenomena such as the rate dependency of the IPMC sensor, a chemo-electro-mechanical model based on the Poisson-Nernst-Planck (PNP) equation for the kinetics of ion diffusion is presented. By solving the governing partial differential equations the frequency response of the IPMC sensor is derived. The physical model is able to describe the dynamic properties of the IPMC sensor and the dependency of the signal on rate of excitations.
Probing infrared detectors through energy-absorption interferometry
NASA Astrophysics Data System (ADS)
Moinard, Dan; Withington, Stafford; Thomas, Christopher N.
2017-08-01
We describe an interferometric technique capable of fully characterizing the optical response of few-mode and multi-mode detectors using only power measurements, and its implementation at 1550 nm wavelength. EnergyAbsorption Interferometry (EAI) is an experimental procedure where the system under test is excited with two coherent, phase-locked sources. As the relative phase between the sources is varied, a fringe is observed in the detector output. Iterating over source positions, the fringes' complex visibilities allow the two-point detector response function to be retrieved: this correlation function corresponds to the state of coherence to which the detector is maximally sensitive. This detector response function can then be decomposed into a set of natural modes, in which the detector is incoherently sensitive to power. EAI therefore allows the reconstruction of the individual degrees of freedom through which the detector can absorb energy, including their relative sensitivities and full spatial forms. Coupling mechanisms into absorbing structures and their underlying solidstate phenomena can thus be studied, with direct applications in improving current infrared detector technology. EAI has previously been demonstrated for millimeter wavelength. Here, we outline the theoretical basis of EAI, and present a room-temperature 1550 nm wavelength infrared experiment we have constructed. Finally, we discuss how this experimental system will allow us to study optical coupling into fiber-based systems and near-infrared detectors.
Francis, Laurent A; Friedt, Jean-Michel; Zhou, Cheng; Bertrand, Patrick
2006-06-15
We show the theoretical and experimental combination of acoustic and optical methods for the in situ quantitative evaluation of the density, the viscosity, and the thickness of soft layers adsorbed on chemically tailored metal surfaces. For the highest sensitivity and an operation in liquids, a Love mode surface acoustic wave (SAW) sensor with a hydrophobized gold-coated sensing area is the acoustic method, while surface plasmon resonance (SPR) on the same gold surface as the optical method is monitored simultaneously in a single setup for the real-time and label-free measurement of the parameters of adsorbed soft layers, which means for layers with a predominant viscous behavior. A general mathematical modeling in equivalent viscoelastic transmission lines is presented to determine the correlation between experimental SAW signal shifts and the waveguide structure including the presence of the adsorbed layer and the supporting liquid from which it segregates. A methodology is presented to identify from SAW and SPR simulations the parameters representatives of the soft layer. During the absorption of a soft layer, thickness or viscosity changes are observed in the experimental ratio of the SAW signal attenuation to the SAW signal phase and are correlated with the theoretical model. As application example, the simulation method is applied to study the thermal behavior of physisorbed PNIPAAm, a polymer whose conformation is sensitive to temperature, under a cycling variation of temperature between 20 and 40 degrees C. Under the assumption of the bulk density and the bulk refractive index of PNIPAAm, thickness and viscosity of the film are obtained from simulations; the viscosity is correlated to the solvent content of the physisorbed layer.
Pant, Sanjay
2018-05-01
A new class of functions, called the 'information sensitivity functions' (ISFs), which quantify the information gain about the parameters through the measurements/observables of a dynamical system are presented. These functions can be easily computed through classical sensitivity functions alone and are based on Bayesian and information-theoretic approaches. While marginal information gain is quantified by decrease in differential entropy, correlations between arbitrary sets of parameters are assessed through mutual information. For individual parameters, these information gains are also presented as marginal posterior variances, and, to assess the effect of correlations, as conditional variances when other parameters are given. The easy to interpret ISFs can be used to (a) identify time intervals or regions in dynamical system behaviour where information about the parameters is concentrated; (b) assess the effect of measurement noise on the information gain for the parameters; (c) assess whether sufficient information in an experimental protocol (input, measurements and their frequency) is available to identify the parameters; (d) assess correlation in the posterior distribution of the parameters to identify the sets of parameters that are likely to be indistinguishable; and (e) assess identifiability problems for particular sets of parameters. © 2018 The Authors.
Slotted Photonic Crystal Sensors
Scullion, Mark G.; Krauss, Thomas F.; Di Falco, Andrea
2013-01-01
Optical biosensors are increasingly being considered for lab-on-a-chip applications due to their benefits such as small size, biocompatibility, passive behaviour and lack of the need for fluorescent labels. The light guiding mechanisms used by many of them results in poor overlap of the optical field with the target molecules, reducing the maximum sensitivity achievable. This review article presents a new platform for optical biosensors, namely slotted photonic crystals, which provide higher sensitivities due to their ability to confine, spatially and temporally, the optical mode peak within the analyte itself. Loss measurements showed values comparable to standard photonic crystals, confirming their ability to be used in real devices. A novel resonant coupler was designed, simulated, and experimentally tested, and was found to perform better than other solutions within the literature. Combining with cavities, microfluidics and biological functionalization allowed proof-of-principle demonstrations of protein binding to be carried out. Higher sensitivities were observed in smaller structures than possible with most competing devices reported in the literature. This body of work presents slotted photonic crystals as a realistic platform for complete on-chip biosensing; addressing key design, performance and application issues, whilst also opening up exciting new ideas for future study. PMID:23503295
ERIC Educational Resources Information Center
Barden, Sejal M.; Shannonhouse, Laura; Mobley, Keith
2015-01-01
Scholars (e.g., Bemak & Chung, 2004) underscore the need for group workers to be culturally sensitive. One group training strategy, cultural immersion, is often employed to develop cultural sensitivity. However, no studies have utilized quasi-experimental methodologies to assess differences in cultural sensitivity between trainees that immerse…
Methods for the quantification of pseudo-vibration sensitivities in laser vibrometry
NASA Astrophysics Data System (ADS)
Martin, P.; Rothberg, S. J.
2011-03-01
Pseudo-vibration sensitivities in laser vibrometry are the consequence of measurement noise generated by surface motions other than that on-axis with the incident laser beam(s), such as transverse and tilt vibrations or rotation. On rougher surfaces, laser speckle is the cause but similar noise is observed in measurements from smoother surfaces. This paper's principal aim is to introduce two experimental methods for quantification, including dedicated data processing, to deliver sensitivities in three forms: a spectral map, a mean level per order and a total rms level. Single and parallel beam vibrometers and different surface roughness or treatment are accommodated, with sensitivities presented for two commercial instruments (beam diameters 90 and 520 µm). For transverse sensitivity, a total rms level around 0.05% is found for the larger beam, a quarter of the level for the smaller beam. For tilt sensitivity, advantage shifts to the smaller beam with a total rms level around 0.45 µm s-1/deg s-1, less than one-third of that for the larger beam. Levels hold fairly constant across the rougher surfaces, reducing only for a polished surface. For rotation sensitivities (radial vibrations), advantage remains with the smaller beam with a total rms level around 2 µm s-1/deg s-1, compared to 5 µm s-1/deg s-1 for the larger beam, while sensitivity reduces with diminishing roughness. These sensitivities are especially valuable to vibrometer users in instrumentation selection and data analysis.
Acerbo, Martin J.; Johnson, Alan Kim
2011-01-01
Behavioral sensitization involves increases in the magnitude of a response to a stimulus after repeated exposures to the same response initiator. Administration of psychomotor stimulants and the induction of appetitive motivational states associated with natural reinforcers like sugar and salt are among experimental manipulations producing behavioral sensitization. In rats, repeated administration of the mineralocorticoid agonist deoxycorticosterone acetate (DOCA) initially induces incremental increases in daily hypertonic saline consumption (i.e., sensitization of sodium appetite) in spite of the retention of sodium. The present studies investigated whether sodium appetite sensitization induced by DOCA shares mechanisms similar to those of psychomotor stimulant-induced sensitization, and whether there is evidence for reciprocal cross-sensitization. In Experiments 1 and 3, rats received control or cocaine treatments to induce locomotor sensitization. A week later DOCA (or vehicle) was administered to generate a sodium appetite. Animals pretreated with cocaine showed a greater sodium appetite. In Experiment 2, the order of the putative sensitizing treatments was reversed. Rats first received either a series of DOCA or vehicle treatments either with or without access to saline and were later tested for sensitization of the locomotor response to cocaine. Animals pretreated with DOCA without access to saline showed greater locomotor responses to cocaine than animals receiving vehicle treatments. Together these experiments indicate that treatments generating a sustained salt appetite and producing cocaine-induced psychomotor responses show reciprocal behavioral cross-sensitization. The underlying mechanisms accounting for this relationship may be the fact that psychostimulants and an unresolved craving for sodium can act as potent stressors. PMID:21352848
Wittmann, C; Heinzle, E
2001-04-01
Experimental design of (13)C-tracer studies for metabolic flux analysis with mass spectrometric determination of labeling patterns was performed for the central metabolism of Corynebacterium glutamicum comprising various flux scenarios. Ratio measurement of mass isotopomer pools of Corynebacterium products lysine, alanine, and trehalose is sufficient to quantify the flux partitioning ratios (i) between glycolysis and pentose phosphate pathways (Phi(PPP)), (ii) between the split pathways in the lysine biosynthesis (Phi(DH)), (iii) at the pyruvate node (Phi(PC)), and reversibilities of (iv) glucose 6-phosphate isomerase (zeta(PGI)), (v) at the pyruvate node (zeta(PC/PEPCK)), and (vi) of transaldolase and transketolases in the PPP. Weighted sensitivities for flux parameters were derived from partial derivatives to quantitatively evaluate experimental approaches and predict precision for estimated flux parameters. Deviation of intensity ratios from ideal values of 1 was used as weighting function. Weighted flux sensitivities can be used to identify optimal type and degree of tracer labeling or potential intensity ratios to be measured. Experimental design for lysine-producing strain C. glutamicum MH 20-22B (Marx et al., Biotechnol. Bioeng. 49, 111-129, 1996) and various potential mutants with different alterations in the flux pattern showed that specific tracer labelings are optimal to quantify a certain flux parameter uninfluenced by the overall flux situation. Identified substrates of choice are [1-(13)C]glucose for the estimation of Phi(PPP) and zeta(PGI) and a 1 : 1 mixture of [U-(12)C/U-(13)C]glucose for the determination of zeta(PC/PEPCK). Phi(PC) can be quantified by feeding [4-(13)C]glucose or [U-(12)C/U-(13)C]glucose (1 : 1), whereas Phi(DH) is accessible via [4-(13)C]glucose. The sensitivity for the quantification of a certain flux parameter can be influenced by superposition through other flux parameters in the network, but substrate and measured mass isotopomers of choice remain the same. In special cases, reduced labeling degree of the tracer substrate can increase the precision of flux analysis. Enhanced precision and flux information can be achieved via multiply labeled substrates. The presented approach can be applied for effective experimental design of (13)C tracer studies for metabolic flux analysis. Intensity ratios of other products such as glutamate, valine, phenylalanine, and riboflavin also sensitively reflect flux parameters, which underlines the great potential of mass spectrometry for flux analysis. Copyright 2001 Academic Press.
Meng, Xiawei; Zhao, Yulong
2016-01-01
A piezoresistive pressure sensor with a beam-membrane-dual-island structure is developed for micro-pressure monitoring in the field of aviation, which requires great sensitivity and overload resistance capacity. The design, fabrication, and test of the sensor are presented in this paper. By analyzing the stress distribution of sensitive elements using the finite element method, a novel structure incorporating sensitive beams with a traditional bossed diaphragm is built up. The proposed structure proved to be advantageous in terms of high sensitivity and high overload resistance compared with the conventional bossed diaphragm and flat diaphragm structures. Curve fittings of surface stress and deflection based on ANSYS simulation results are performed to establish the sensor equations. Fabricated on an n-type single crystal silicon wafer, the sensor chips are wire-bonded to a printed circuit board (PCB) and packaged for experiments. The static and dynamic characteristics are tested and discussed. Experimental results show that the sensor has a sensitivity as high as 17.339 μV/V/Pa in the range of 500 Pa at room temperature, and a high overload resistance of 200 times overpressure. Due to the excellent performance, the sensor can be applied in measuring micro-pressure lower than 500 Pa. PMID:27005627
An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.
Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans
2014-09-01
Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.
NASA Astrophysics Data System (ADS)
Chen, Tao; Ye, Meng-li; Liu, Shu-liang; Deng, Yan
2018-03-01
In view of the principle for occurrence of cross-sensitivity, a series of calibration experiments are carried out to solve the cross-sensitivity problem of embedded fiber Bragg gratings (FBGs) using the reference grating method. Moreover, an ultrasonic-vibration-assisted grinding (UVAG) model is established, and finite element analysis (FEA) is carried out under the monitoring environment of embedded temperature measurement system. In addition, the related temperature acquisition tests are set in accordance with requirements of the reference grating method. Finally, comparative analyses of the simulation and experimental results are performed, and it may be concluded that the reference grating method may be utilized to effectively solve the cross-sensitivity of embedded FBGs.
Low energy probes of PeV scale sfermions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altmannshofer, Wolfgang; Harnik, Roni; Zupan, Jure
2013-11-27
We derive bounds on squark and slepton masses in mini-split supersymmetry scenario using low energy experiments. In this setup gauginos are at the TeV scale, while sfermions are heavier by a loop factor. We cover the most sensitive low energy probes including electric dipole moments (EDMs), meson oscillations and charged lepton flavor violation (LFV) transitions. A leading log resummation of the large logs of gluino to sfermion mass ratio is performed. A sensitivity to PeV squark masses is obtained at present from kaon mixing measurements. A number of observables, including neutron EDMs, mu->e transitions and charmed meson mixing, will startmore » probing sfermion masses in the 100 TeV-1000 TeV range with the projected improvements in the experimental sensitivities. We also discuss the implications of our results for a variety of models that address the flavor hierarchy of quarks and leptons. We find that EDM searches will be a robust probe of models in which fermion masses are generated radiatively, while LFV searches remain sensitive to simple-texture based flavor models.« less
A Novel High-Sensitivity, Low-Power, Liquid Crystal Temperature Sensor
Algorri, José Francisco; Urruchi, Virginia; Bennis, Noureddine; Sánchez-Pena, José Manuel
2014-01-01
A novel temperature sensor based on nematic liquid crystal permittivity as a sensing magnitude, is presented. This sensor consists of a specific micrometric structure that gives considerable advantages from other previous related liquid crystal (LC) sensors. The analytical study reveals that permittivity change with temperature is introduced in a hyperbolic cosine function, increasing the sensitivity term considerably. The experimental data has been obtained for ranges from −6 °C to 100 °C. Despite this, following the LC datasheet, theoretical ranges from −40 °C to 109 °C could be achieved. These results have revealed maximum sensitivities of 33 mVrms/°C for certain temperature ranges; three times more than of most silicon temperature sensors. As it was predicted by the analytical study, the micrometric size of the proposed structure produces a high output voltage. Moreover the voltage's sensitivity to temperature response can be controlled by the applied voltage. This response allows temperature measurements to be carried out without any amplification or conditioning circuitry, with very low power consumption. PMID:24721771
Cold Pressor Pain Sensitivity in Twins Discordant for Chronic Fatigue Syndrome
Ullrich, Phil; Afari, Niloofar; Jacobsen, Clemma; Goldberg, Jack; Buchwald, Dedra
2010-01-01
Objective Individuals with chronic fatigue syndrome (CFS) experience many pain symptoms. The present study examined whether pain and fatigue ratings and pain threshold and tolerance levels for cold pain differed between twins with CFS and their cotwins without CFS. Design Cotwin control design to assess cold pain sensitivity, pain, and fatigue in monozygotic twins discordant for CFS. Patients and Setting Fifteen twin pairs discordant for CFS recruited from the volunteer Chronic Fatigue Twin Registry at the University of Washington. Results Although cold pain threshold and tolerance levels were slightly lower in twins with CFS than their cotwins without CFS, these differences failed to reach statistical significance. Subjective ratings of pain and fatigue at multiple time points during the experimental protocol among twins with CFS were significantly higher than ratings of pain (p = 0.003) and fatigue (p < 0.001) by their cotwins without CFS. Conclusions These results, while preliminary, highlight the perceptual and cognitive components to the pain experience in CFS. Future studies should focus on examining the heritability of pain sensitivity and the underlying mechanisms involved in the perception of pain sensitivity in CFS. PMID:17371408
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karaulanov, Todor; Savukov, Igor; Kim, Young Jin
We constructed a spin-exchange relaxation-free (SERF) magnetometer with a small angle between the pump and probe beams facilitating a multi-channel design with a flat pancake cell. This configuration provides almost complete overlap of the beams in the cell, and prevents the pump beam from entering the probe detection channel. By coupling the lasers in multi-mode fibers, without an optical isolator or field modulation, we demonstrate a sensitivity of 10 fTmore » $$/\\sqrt{\\text{Hz}}$$ for frequencies between 10 Hz and 100 Hz. In addition to the experimental study of sensitivity, we present a theoretical analysis of SERF magnetometer response to magnetic fields for small-angle and parallel-beam configurations, and show that at optimal DC offset fields the magnetometer response is comparable to that in the orthogonal-beam configuration. Based on the analysis, we also derive fundamental and probe-limited sensitivities for the arbitrary non-orthogonal geometry. The expected practical and fundamental sensitivities are of the same order as those in the orthogonal geometry. As a result, we anticipate that our design will be useful for magnetoencephalography (MEG) and magnetocardiography (MCG) applications.« less
Prediction of coefficients of thermal expansion for unidirectional composites
NASA Technical Reports Server (NTRS)
Bowles, David E.; Tompkins, Stephen S.
1989-01-01
Several analyses for predicting the longitudinal, alpha(1), and transverse, alpha(2), coefficients of thermal expansion of unidirectional composites were compared with each other, and with experimental data on different graphite fiber reinforced resin, metal, and ceramic matrix composites. Analytical and numerical analyses that accurately accounted for Poisson restraining effects in the transverse direction were in consistently better agreement with experimental data for alpha(2), than the less rigorous analyses. All of the analyses predicted similar values of alpha(1), and were in good agreement with the experimental data. A sensitivity analysis was conducted to determine the relative influence of constituent properties on the predicted values of alpha(1), and alpha(2). As would be expected, the prediction of alpha(1) was most sensitive to longitudinal fiber properties and the prediction of alpha(2) was most sensitive to matrix properties.
High-sensitivity pressure sensor based on fiber Mach-Zehnder interferometer
NASA Astrophysics Data System (ADS)
Wu, Yue; Xu, Yao; Yang, Yuguang; Jin, Wenxing; Jiang, Youchao; Shen, Ya; Jian, Shuisheng
2017-10-01
In this paper we propose and experimentally demonstrate an optical fiber structure sensor based on a Mach-Zehnder interferometer for pressure measurement. The fiber sensor is composed of a single-mode-no-core-single-mode structure, a section of capillary pure silica tube and refractive index matching fluid (RIMF). As the pressure decreases, the sealed air in the tube expands and the liquid level of the RIMF increases, which causes a wavelength shift of the interferometer. The measurement of the pressure variation can thus be achieved by monitoring the wavelength shift. The experimental results agree well with the numerical simulation, and a maximum pressure sensitivity of 266.6 nm Mpa-1 is achieved experimentally. Furthermore, the proposed fiber sensor has the potential to obtain higher sensitivity by enlarging the length of the air cavity.
Optically pre-amplified lidar-radar
NASA Astrophysics Data System (ADS)
Morvan, Loic; Dolfi, Daniel; Huignard, Jean-Pierre
2001-09-01
We present the concept of an optically pre-amplified intensity modulated lidar, where the modulation frequency is in the microwave domain (1-10 GHz). Such a system permits to combine directivity of laser beams with mature radar processing. As an intensity modulated or dual-frequency laser beam is directed on a target, the backscattered intensity is collected by an optical system, pass through an optical preamplifier, and is detected on a high speed photodiode in a direct detection scheme. A radar type processing permits then to extract range, speed and identification information. The association of spatially multimode amplifier and direct detection allows low sensitivity to atmospheric turbulence and large field of view. We demonstrated theoretically that optical pre-amplification can greatly enhance sensitivity, even in spatially multimode amplifiers, such as free-space amplifier or multimode doped fiber. Computed range estimates based on this concept are presented. Laboratory demonstrations using 1 to 3 GHz modulated laser sources and >20 dB gain in multimode amplifiers are detailed. Preliminary experimental results on range and speed measurements and possible use for large amplitude vibrometry will be presented.
Incidental fear cues increase monetary loss aversion.
Schulreich, Stefan; Gerhardt, Holger; Heekeren, Hauke R
2016-04-01
In many everyday decisions, people exhibit loss aversion-a greater sensitivity to losses relative to gains of equal size. Loss aversion is thought to be (at least partly) mediated by emotional--in particular, fear-related--processes. Decision research has shown that even incidental emotions, which are unrelated to the decision at hand, can influence decision making. The effect of incidental fear on loss aversion, however, is thus far unclear. In two studies, we experimentally investigated how incidental fear cues, presented during (Study 1) or before (Study 2) choices to accept or reject mixed gambles over real monetary stakes, influence monetary loss aversion. We find that the presentation of fearful faces, relative to the presentation of neutral faces, increased risk aversion-an effect that could be attributed to increased loss aversion. The size of this effect was moderated by psychopathic personality: Fearless dominance, in particular its interpersonal facet, but not self-centered impulsivity, attenuated the effect of incidental fear cues on loss aversion, consistent with reduced fear reactivity. Together, these results highlight the sensitivity of loss aversion to the affective context. (c) 2016 APA, all rights reserved).
Tao, Yunwen; Zou, Wenli; Cremer, Dieter; Kraka, Elfi
2017-10-26
A novel approach is presented to assess chemical similarity based the local vibrational mode analysis developed by Konkoli and Cremer. The local mode frequency shifts are introduced as similarity descriptors that are sensitive to any electronic structure change. In this work, 59 different monosubstituted benzenes are compared. For a subset of 43 compounds, for which experimental data was available, the ortho-/para- and meta-directing effect in electrophilic aromatic substitution reactions could be correctly reproduced, proving the robustness of the new similarity index. For the remaining 16 compounds, the directing effect was predicted. The new approach is broadly applicable to all compounds for which either experimental or calculated vibrational frequency information is available.
Fabry-Perot cavity cascaded sagnac loops for temperature and strain measurements
NASA Astrophysics Data System (ADS)
Shangguan, Chunmei; Zhang, Wen; Hei, Wei; Luo, Fei; Zhu, Lianqing
2018-04-01
The fabrication process and temperature and strain characterizations of an all-fiber sensor are presented. The sensing structure based on a Fabry-Perot cavity (FPC) and sagnac loops was proposed and experimentally demonstrated for measurements of temperature and strain. The FPC consists of a micropiece of chemical etched multimode fiber end face, welded with another single mode fiber. Then, the sagnac loops composed of polarization maintaining fiber was connected to the FPC. The sensor was fabricated and tested for temperature and strain. Experimental results show that sensitivity of temperature and strain is 0.71 ± 0.03 nm / ° C and 1.30 ± 0.01 pm / μɛ, respectively; the linearity are 0.9970 and 0.9996, respectively.
Principle, system, and applications of tip-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Zhang, MingQian; Wang, Rui; Wu, XiaoBin; Wang, Jia
2012-08-01
Raman spectroscopy is a powerful technique in chemical information characterization. However, this spectral method is subject to two obstacles in nano-material detection. One is diffraction limited spatial resolution, and the other is its inherent small Raman cross section and weak signaling. To resolve these problems, a new approach has been developed, denoted as tip-enhanced Raman spectroscopy (TERS). TERS is capable of high-resolution and high-sensitivity detection and demonstrated to be a promising spectroscopic and micro-topographic method to characterize nano-materials and nanostructures. In this paper, the principle and experimental system of TERS are discussed. The latest application of TERS in molecule detection, biological specimen identification, nanao-material characterization, and semi-conductor material determination with some specific experimental examples are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
López C, Diana C.; Wozny, Günter; Flores-Tlacuahuac, Antonio
2016-03-23
The lack of informative experimental data and the complexity of first-principles battery models make the recovery of kinetic, transport, and thermodynamic parameters complicated. We present a computational framework that combines sensitivity, singular value, and Monte Carlo analysis to explore how different sources of experimental data affect parameter structural ill conditioning and identifiability. Our study is conducted on a modified version of the Doyle-Fuller-Newman model. We demonstrate that the use of voltage discharge curves only enables the identification of a small parameter subset, regardless of the number of experiments considered. Furthermore, we show that the inclusion of a single electrolyte concentrationmore » measurement significantly aids identifiability and mitigates ill-conditioning.« less
Beauty photoproduction at HERA: k{sub T}-factorization versus experimental data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lipatov, A.V.; Zotov, N.P.
We present calculations of the beauty photoproduction at HERA collider in the framework of the k{sub T}-factorization approach. Both direct and resolved photon contributions are taken into account. The unintegrated gluon densities in a proton and in a photon are obtained from the full CCFM, from unified BFKL-DGLAP evolution equations as well as from the Kimber-Martin-Ryskin prescription. We investigate different production rates (both inclusive and associated with hadronic jets) and compare our theoretical predictions with the recent experimental data taken by the H1 and ZEUS collaborations. Special attention is put on the x{sub {gamma}}{sup obs} variable which is sensitive tomore » the relative contributions to the beauty production cross section.« less
Effect of an entrained air bubble on the acoustics of an ink channel.
Jeurissen, Roger; de Jong, Jos; Reinten, Hans; van den Berg, Marc; Wijshoff, Herman; Versluis, Michel; Lohse, Detlef
2008-05-01
Piezo-driven inkjet systems are very sensitive to air entrapment. The entrapped air bubbles grow by rectified diffusion in the ink channel and finally result in nozzle failure. Experimental results on the dynamics of fully grown air bubbles are presented. It is found that the bubble counteracts the pressure buildup necessary for the droplet formation. The channel acoustics and the air bubble dynamics are modeled. For good agreement with the experimental data it is crucial to include the confined geometry into the model: The air bubble acts back on the acoustic field in the channel and thus on its own dynamics. This two-way coupling limits further bubble growth and thus determines the saturation size of the bubble.
NASA Astrophysics Data System (ADS)
Grigorie, Teodor Lucian; Corcau, Ileana Jenica; Tudosie, Alexandru Nicolae
2017-06-01
The paper presents a way to obtain an intelligent miniaturized three-axial accelerometric sensor, based on the on-line estimation and compensation of the sensor errors generated by the environmental temperature variation. Taking into account that this error's value is a strongly nonlinear complex function of the values of environmental temperature and of the acceleration exciting the sensor, its correction may not be done off-line and it requires the presence of an additional temperature sensor. The proposed identification methodology for the error model is based on the least square method which process off-line the numerical values obtained from the accelerometer experimental testing for different values of acceleration applied to its axes of sensitivity and for different values of operating temperature. A final analysis of the error level after the compensation highlights the best variant for the matrix in the error model. In the sections of the paper are shown the results of the experimental testing of the accelerometer on all the three sensitivity axes, the identification of the error models on each axis by using the least square method, and the validation of the obtained models with experimental values. For all of the three detection channels was obtained a reduction by almost two orders of magnitude of the acceleration absolute maximum error due to environmental temperature variation.
Refractive Index Sensing Using Visible Electromagnetic Resonances of Supported Cu2O Particles.
Susman, Mariano D; Vaskevich, Alexander; Rubinstein, Israel
2017-03-08
Plasmonic metal nanostructures, in colloidal or surface-supported forms, have been extensively studied in the context of metamaterials design and applications, in particular as refractometric sensing platforms. Recently, high refractive index (high-n) dielectric subwavelength structures have been experimentally shown to support strong Mie scattering resonances, predicted to exhibit analogous refractive index sensing capabilities. Here we present the first experimental demonstration of the use of supported high-n dielectric nano/microparticle ensembles as refractive index sensing platforms, using cuprous oxide as a model high-n material. Single-crystalline Cu 2 O particles were deposited on transparent substrates using a chemical deposition scheme, showing well-defined electric and magnetic dipolar resonances (EDR and MDR, respectively) in the visible range, which change in intensity and wavelength upon changing the medium refractive index (n m ). The significant modulation of the MDR intensity when n m is modified appears to be the most valuable empirical sensing parameter. The Mie scattering properties of Cu 2 O particles, particularly the spectral dependence of the MDR on n m , are theoretically modeled to support the experimental observations. MDR extinction changes (i.e., refractive index sensitivity) per particle are >100 times higher compared to localized surface plasmon resonance (LSPR) changes in supported Au nanoislands, encouraging the evaluation of Cu 2 O and other high-n dielectric particles and sensing modes in order to improve the sensitivity in optical (bio)sensing applications.
An improved Overhauser magnetometer for Earth's magnetic field observation
NASA Astrophysics Data System (ADS)
Fan, Shifang; Chen, Shudong; Zhang, Shuang; Guo, Xin; Cao, Qiong
2016-09-01
Overhauser magnetometer is a kind of high-precision devices for magnetostatic field measurement. It is widely used in geological survey, earth field variations, UXO detection etc. However, the original Overhauser magnetometer JOM-2 shows great shortcomings of low signal to noise ratio (SNR) and high power consumption, which directly affect the performance of the device. In order to increase the sensitivity and reduce power consumption, we present an improved Overhauser magnetometer. Firstly, compared with the original power board which suffers from heavy noise for improper EMC design, an improved power broad with 20mV peak to peak noise is presented in this paper. Then, the junction field effect transistor (JFET) is used as pre-amplifier in our new design, to overcome the higher current noise produced by the original instrumentation amplifier. By adjusting the parameters carefully low noise factor down to 0.5 dB can be obtained. Finally, the new architecture of ARM + CPLD is adopted to replace the original one with DSP+CPLD. So lower power consumption and greater flash memory can be realized. With these measures, an improved Overhauser magnetometer with higher sensitivity and lower power consumption is design here. The experimental results indicate that the sensitivity of the improved Overhauser magnetometer is 0.071nT, which confirms that the new magnetometer is sensitive to earth field measurement.
Appelbaum, L Gregory; Cain, Matthew S; Darling, Elise F; Mitroff, Stephen R
2013-08-01
Action video game playing has been experimentally linked to a number of perceptual and cognitive improvements. These benefits are captured through a wide range of psychometric tasks and have led to the proposition that action video game experience may promote the ability to extract statistical evidence from sensory stimuli. Such an advantage could arise from a number of possible mechanisms: improvements in visual sensitivity, enhancements in the capacity or duration for which information is retained in visual memory, or higher-level strategic use of information for decision making. The present study measured the capacity and time course of visual sensory memory using a partial report performance task as a means to distinguish between these three possible mechanisms. Sensitivity measures and parameter estimates that describe sensory memory capacity and the rate of memory decay were compared between individuals who reported high evels and low levels of action video game experience. Our results revealed a uniform increase in partial report accuracy at all stimulus-to-cue delays for action video game players but no difference in the rate or time course of the memory decay. The present findings suggest that action video game playing may be related to enhancements in the initial sensitivity to visual stimuli, but not to a greater retention of information in iconic memory buffers.
NASA Astrophysics Data System (ADS)
Masychev, Viktor I.; Risovannaya, Olga N.
2005-03-01
Results of in vivo experiments have shown the maximum effectiveness of combined use of photo sensitizer 0,1% gel Radachlorine simultaneously with continuous and super pulse low energy irradiation of the diode laser with energy density 400 J/cm2, and power 1W. Given parameters have lead to complete elimination of Streptococcus pyogenes from inflammation foci in oral cavity of experimental animals.
Photonic Jets for Strained-Layer Superlattice Infrared Photodetector Enhancement
2014-06-25
top of a 40 µm photodetector fixed into position using a silicone rubber . As illustrated in Fig. 2, the spectral response was characterized before and...midwave-infrared spectral band (3-5 ?m). We optimized the design of these structures and experimentally demonstrated the increased sensitivity compared to...midwave-infrared spectral band (3-5 ?m). We optimized the design of these structures and experimentally demonstrated the increased sensitivity
Reduction and Uncertainty Analysis of Chemical Mechanisms Based on Local and Global Sensitivities
NASA Astrophysics Data System (ADS)
Esposito, Gaetano
Numerical simulations of critical reacting flow phenomena in hypersonic propulsion devices require accurate representation of finite-rate chemical kinetics. The chemical kinetic models available for hydrocarbon fuel combustion are rather large, involving hundreds of species and thousands of reactions. As a consequence, they cannot be used in multi-dimensional computational fluid dynamic calculations in the foreseeable future due to the prohibitive computational cost. In addition to the computational difficulties, it is also known that some fundamental chemical kinetic parameters of detailed models have significant level of uncertainty due to limited experimental data available and to poor understanding of interactions among kinetic parameters. In the present investigation, local and global sensitivity analysis techniques are employed to develop a systematic approach of reducing and analyzing detailed chemical kinetic models. Unlike previous studies in which skeletal model reduction was based on the separate analysis of simple cases, in this work a novel strategy based on Principal Component Analysis of local sensitivity values is presented. This new approach is capable of simultaneously taking into account all the relevant canonical combustion configurations over different composition, temperature and pressure conditions. Moreover, the procedure developed in this work represents the first documented inclusion of non-premixed extinction phenomena, which is of great relevance in hypersonic combustors, in an automated reduction algorithm. The application of the skeletal reduction to a detailed kinetic model consisting of 111 species in 784 reactions is demonstrated. The resulting reduced skeletal model of 37--38 species showed that the global ignition/propagation/extinction phenomena of ethylene-air mixtures can be predicted within an accuracy of 2% of the full detailed model. The problems of both understanding non-linear interactions between kinetic parameters and identifying sources of uncertainty affecting relevant reaction pathways are usually addressed by resorting to Global Sensitivity Analysis (GSA) techniques. In particular, the most sensitive reactions controlling combustion phenomena are first identified using the Morris Method and then analyzed under the Random Sampling -- High Dimensional Model Representation (RS-HDMR) framework. The HDMR decomposition shows that 10% of the variance seen in the extinction strain rate of non-premixed flames is due to second-order effects between parameters, whereas the maximum concentration of acetylene, a key soot precursor, is affected by mostly only first-order contributions. Moreover, the analysis of the global sensitivity indices demonstrates that improving the accuracy of the reaction rates including the vinyl radical, C2H3, can drastically reduce the uncertainty of predicting targeted flame properties. Finally, the back-propagation of the experimental uncertainty of the extinction strain rate to the parameter space is also performed. This exercise, achieved by recycling the numerical solutions of the RS-HDMR, shows that some regions of the parameter space have a high probability of reproducing the experimental value of the extinction strain rate between its own uncertainty bounds. Therefore this study demonstrates that the uncertainty analysis of bulk flame properties can effectively provide information on relevant chemical reactions.
2D-Raman-THz spectroscopy: A sensitive test of polarizable water models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamm, Peter, E-mail: peter.hamm@chem.uzh.ch
2014-11-14
In a recent paper, the experimental 2D-Raman-THz response of liquid water at ambient conditions has been presented [J. Savolainen, S. Ahmed, and P. Hamm, Proc. Natl. Acad. Sci. U. S. A. 110, 20402 (2013)]. Here, all-atom molecular dynamics simulations are performed with the goal to reproduce the experimental results. To that end, the molecular response functions are calculated in a first step, and are then convoluted with the laser pulses in order to enable a direct comparison with the experimental results. The molecular dynamics simulation are performed with several different water models: TIP4P/2005, SWM4-NDP, and TL4P. As polarizability is essentialmore » to describe the 2D-Raman-THz response, the TIP4P/2005 water molecules are amended with either an isotropic or a anisotropic polarizability a posteriori after the molecular dynamics simulation. In contrast, SWM4-NDP and TL4P are intrinsically polarizable, and hence the 2D-Raman-THz response can be calculated in a self-consistent way, using the same force field as during the molecular dynamics simulation. It is found that the 2D-Raman-THz response depends extremely sensitively on details of the water model, and in particular on details of the description of polarizability. Despite the limited time resolution of the experiment, it could easily distinguish between various water models. Albeit not perfect, the overall best agreement with the experimental data is obtained for the TL4P water model.« less
Improvements to the YbF electron electric dipole moment experiment
NASA Astrophysics Data System (ADS)
Sauer, B. E.; Rabey, I. M.; Devlin, J. A.; Tarbutt, M. R.; Ho, C. J.; Hinds, E. A.
2017-04-01
The standard model of particle physics predicts that the permanent electric dipole moment (EDM) of the electron is very nearly zero. Many extensions to the standard model predict an electron EDM just below current experimental limits. We are currently working to improve the sensitivity of the Imperial College YbF experiment. We have implemented combined laser-radiofrequency pumping techniques which both increase the number of molecules which participate in the EDM experiment and also increase the probability of detection. Combined, these techniques give nearly two orders of magnitude increase in the experimental sensitivity. At this enhanced sensitivity magnetic effects which were negligible become important. We have developed a new way to construct the electrodes for electric field plates which minimizes the effect of magnetic Johnson noise. The new YbF experiment is expected to comparable in sensitivity to the most sensitive measurements of the electron EDM to date. We will also discuss laser cooling techniques which promise an even larger increase in sensitivity.
Highly sensitive magnetic field sensor based on microfiber coupler with magnetic fluid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Longfeng; Pu, Shengli, E-mail: shlpu@usst.edu.cn; Tang, Jiali
2015-05-11
A kind of magnetic field sensor using a microfiber coupler (MFC) surrounded with magnetic fluid (MF) is proposed and experimentally demonstrated. As the MFC is strongly sensitive to the surrounding refractive index (RI) and MF's RI is sensitive to magnetic field, the magnetic field sensing function of the proposed structure is realized. Interrogation of magnetic field strength is achieved by measuring the dip wavelength shift and transmission loss change of the transmission spectrum. The experimental results show that the sensitivity of the sensor is wavelength-dependent. The maximum sensitivity of 191.8 pm/Oe is achieved at wavelength of around 1537 nm in this work.more » In addition, a sensitivity of −0.037 dB/Oe is achieved by monitoring variation of the fringe visibility. These suggest the potential applications of the proposed structure in tunable all-in-fiber photonic devices such as magneto-optical modulator, filter, and sensing.« less
Sundling, Vibeke; Gulbrandsen, Pål; Straand, Jørund
2013-01-10
In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a "gold standard", images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education.
2013-01-01
Background In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. Methods This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a “gold standard”, images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). Results The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. Conclusions The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education. PMID:23305337
Vigil, Jacob M; Rowell, Lauren N; Chouteau, Simone; Chavez, Alexandre; Jaramillo, Elisa; Neal, Michael; Waid, David
2013-01-01
This is the first study to examine how both structural and functional components of individuals' social networks may moderate the association between biological sex and experimental pain sensitivity. One hundred and fifty-two healthy adults (mean age = 22yrs., 53% males) were measured for cold pressor task (CPT) pain sensitivity (i.e., intensity ratings) and core aspects of social networks (e.g., proportion of friends vs. family, affection, affirmation, and aid). Results showed consistent sex differences in how social network structures and intimate relationship functioning modulated pain sensitivity. Females showed higher pain sensitivity when their social networks consisted of a higher proportion of intimate types of relationship partners (e.g., kin vs. non kin), when they had known their network partners for a longer period of time, and when they reported higher levels of logistical support from their significant other (e.g., romantic partner). Conversely, males showed distinct patterns in the opposite direction, including an association between higher levels of logistical support from one's significant other and lower CPT pain intensity. These findings show for the first time that the direction of sex differences in exogenous pain sensitivity is likely dependent on fundamental components of the individual's social environment. The utility of a social-signaling perspective of pain behaviors for examining, comparing, and interpreting individual and group differences in experimental and clinical pain reports is discussed.
Vigil, Jacob M.; Rowell, Lauren N.; Chouteau, Simone; Chavez, Alexandre; Jaramillo, Elisa; Neal, Michael; Waid, David
2013-01-01
This is the first study to examine how both structural and functional components of individuals’ social networks may moderate the association between biological sex and experimental pain sensitivity. One hundred and fifty-two healthy adults (mean age = 22yrs., 53% males) were measured for cold pressor task (CPT) pain sensitivity (i.e., intensity ratings) and core aspects of social networks (e.g., proportion of friends vs. family, affection, affirmation, and aid). Results showed consistent sex differences in how social network structures and intimate relationship functioning modulated pain sensitivity. Females showed higher pain sensitivity when their social networks consisted of a higher proportion of intimate types of relationship partners (e.g., kin vs. non kin), when they had known their network partners for a longer period of time, and when they reported higher levels of logistical support from their significant other (e.g., romantic partner). Conversely, males showed distinct patterns in the opposite direction, including an association between higher levels of logistical support from one’s significant other and lower CPT pain intensity. These findings show for the first time that the direction of sex differences in exogenous pain sensitivity is likely dependent on fundamental components of the individual’s social environment. The utility of a social-signaling perspective of pain behaviors for examining, comparing, and interpreting individual and group differences in experimental and clinical pain reports is discussed. PMID:24223836
Overview of processing activities aimed at higher efficiencies and economical production
NASA Technical Reports Server (NTRS)
Bickler, D. B.
1985-01-01
An overview of processing activities aimed at higher efficiencies and economical production were presented. Present focus is on low-cost process technology for higher-efficiency cells of up to 18% or higher. Process development concerns center on the use of less than optimum silicon sheet, the control of production yields, and making uniformly efficient large-area cells. High-efficiency cell factors that require process development are bulk material perfection, very shallow junction formation, front-surface passivation, and finely detailed metallization. Better bulk properties of the silicon sheet and the keeping of those qualities throughout large areas during cell processing are required so that minority carrier lifetimes are maintained and cell performance is not degraded by high doping levels. When very shallow junctions are formed, the process must be sensitive to metallizatin punch-through, series resisitance in the cell, and control of dopant leaching during surface passivation. There is a need to determine the sensitivity to processing by mathematical modeling and experimental activities.
Photoacoustic sensor for medical diagnostics
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann
2004-03-01
The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.
Optimization of Passive Low Power Wireless Electromagnetic Energy Harvesters
Nimo, Antwi; Grgić, Dario; Reindl, Leonhard M.
2012-01-01
This work presents the optimization of antenna captured low power radio frequency (RF) to direct current (DC) power converters using Schottky diodes for powering remote wireless sensors. Linearized models using scattering parameters show that an antenna and a matched diode rectifier can be described as a form of coupled resonator with different individual resonator properties. The analytical models show that the maximum voltage gain of the coupled resonators is mainly related to the antenna, diode and load (remote sensor) resistances at matched conditions or resonance. The analytical models were verified with experimental results. Different passive wireless RF power harvesters offering high selectivity, broadband response and high voltage sensitivity are presented. Measured results show that with an optimal resistance of antenna and diode, it is possible to achieve high RF to DC voltage sensitivity of 0.5 V and efficiency of 20% at −30 dBm antenna input power. Additionally, a wireless harvester (rectenna) is built and tested for receiving range performance. PMID:23202014
Optimization of passive low power wireless electromagnetic energy harvesters.
Nimo, Antwi; Grgić, Dario; Reindl, Leonhard M
2012-10-11
This work presents the optimization of antenna captured low power radio frequency (RF) to direct current (DC) power converters using Schottky diodes for powering remote wireless sensors. Linearized models using scattering parameters show that an antenna and a matched diode rectifier can be described as a form of coupled resonator with different individual resonator properties. The analytical models show that the maximum voltage gain of the coupled resonators is mainly related to the antenna, diode and load (remote sensor) resistances at matched conditions or resonance. The analytical models were verified with experimental results. Different passive wireless RF power harvesters offering high selectivity, broadband response and high voltage sensitivity are presented. Measured results show that with an optimal resistance of antenna and diode, it is possible to achieve high RF to DC voltage sensitivity of 0.5 V and efficiency of 20% at -30 dBm antenna input power. Additionally, a wireless harvester (rectenna) is built and tested for receiving range performance.
NASA Technical Reports Server (NTRS)
Lim, Kair Chuan
1986-01-01
Low frequency combustion instability, known as chugging, is consistently experienced during shutdown in the fuel and oxidizer preburners of the Space Shuttle Main Engines. Such problems always occur during the helium purge of the residual oxidizer from the preburner manifolds during the shutdown sequence. Possible causes and triggering mechanisms are analyzed and details in modeling the fuel preburner chug are presented. A linearized chugging model, based on the foundation of previous models, capable of predicting the chug occurrence is discussed and the predicted results are presented and compared to experimental work performed by NASA. Sensitivity parameters such as chamber pressure, fuel and oxidizer temperatures, and the effective bulk modulus of the liquid oxidizer are considered in analyzing the fuel preburner chug. The computer program CHUGTEST is utilized to generate the stability boundary for each sensitivity study and the region for stable operation is identified.
Parallel Force Assay for Protein-Protein Interactions
Aschenbrenner, Daniela; Pippig, Diana A.; Klamecka, Kamila; Limmer, Katja; Leonhardt, Heinrich; Gaub, Hermann E.
2014-01-01
Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay. PMID:25546146
Parallel force assay for protein-protein interactions.
Aschenbrenner, Daniela; Pippig, Diana A; Klamecka, Kamila; Limmer, Katja; Leonhardt, Heinrich; Gaub, Hermann E
2014-01-01
Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay.
Orthogonal fluxgate mechanism operated with dc biased excitation
NASA Astrophysics Data System (ADS)
Sasada, I.
2002-05-01
A mode of operation is presented for an orthogonal fluxgate built with a thin magnetic wire. By adding a proper dc bias to the wire excitation, the new mode is easily established. In this case, the fundamental component of the induced voltage at the sensing coil (secondary voltage) is made sensitive to the axial magnetic field, compared to the second harmonic in a conventional orthogonal fluxgate. The operating principle is explained using a magnetization rotation model. A method is proposed to cancel the offset that is inevitable when the magnetic anisotropy is present in a magnetic wire at an angle to its circumference. Experimental results are shown for a sensor head consisting of a 2-cm-long Co-based amorphous wire 120 μm in diameter with a 220-turn sensing coil. The sensitivity obtained is higher than that obtained using a conventional type of the orthogonal fluxgate built with the same sensor head. It is also demonstrated that the proposed method for canceling the offset works well.
A MEMS-based Benzene Gas Sensor with a Self-heating WO3 Sensing Layer
Ke, Ming-Tsun; Lee, Mu-Tsun; Lee, Chia-Yen; Fu, Lung-Ming
2009-01-01
In the study, a MEMS-based benzene gas sensor is presented, consisting of a quartz substrate, a thin-film WO3 sensing layer, an integrated Pt micro-heater, and Pt interdigitated electrodes (IDEs). When benzene is present in the atmosphere, oxidation occurs on the heated WO3 sensing layer. This causes a change in the electrical conductivity of the WO3 film, and hence changes the resistance between the IDEs. The benzene concentration is then computed from the change in the measured resistance. A specific orientation of the WO3 layer is obtained by optimizing the sputtering process parameters. It is found that the sensitivity of the gas sensor is optimized at a working temperature of 300 °C. At the optimal working temperature, the experimental results show that the sensor has a high degree of sensitivity (1.0 KΩ ppm−1), a low detection limit (0.2 ppm) and a rapid response time (35 s). PMID:22574052
Optoelectronics research for communication programs at the Goddard Space Flight Center
NASA Technical Reports Server (NTRS)
Krainak, Michael A.
1991-01-01
Current optoelectronics research and development of high-power, high-bandwidth laser transmitters, high-bandwidth, high-sensitivity optical receivers, pointing, acquisition and tracking components, and experimental and theoretical system modeling at the NASA Goddard Space Flight Center is reviewed. Program hardware and space flight milestones are presented. It is believed that these experiments will pave the way for intersatellite optical communications links for both the NASA Advanced Tracking and Data Relay Satellite System and commercial users in the 21st century.
NASA Technical Reports Server (NTRS)
1983-01-01
A computer code which can account for plastic deformation effects on stress generated in silicon sheet grown at high speeds is fully operative. Stress and strain rate distributions are presented for two different sheet temperature profiles. The calculations show that residual stress levels are very sensitive to details of the cooling profile in a sheet with creep. Experimental work has been started in several areas to improve understanding of ribbon temperature profiles and stress distributions associated with a 10 cm wide ribbon cartridge system.
Growth of Staphylococcus aureus and Fungi in Beef Snacks at Various Levels of Water Activity
1988-01-01
concentration, the detection methods used were sensitive to 0.1 yg/mL. The assay method used in the present study detects 0.1 to 1 ng/mL of...DoD 5200.1-R, Information Security Program Regulation, Chapter IX For Unclassified/Limited Distribution Documents: Destroy by any method that...CONTENTS PREFACE iii LIST OF FI8ÜRES v LIST OF TABLES . v INTRODUCTION 1 MATERIALS AND METHODS 1 Bee-f snack production 1 Experimental samples 1
NASA Astrophysics Data System (ADS)
Ismailov, N. D.; Talipov, N. Kh.; Voitsekhovskii, A. V.
2018-04-01
The results of an experimental study of photoelectric characteristics of two-layer photoresistors based on p-Cd x Hg1- x Te (x = 0.24-0.28) with a thin near-surface layer of n-type obtained by treatment in atmospheric gas plasma are presented. It is shown that the presence of a potential barrier between the p- and n-regions causes high photosensitivity and speed of operation of such photoresistors at T = 77 K
Strain gauge using Si-based optical microring resonator.
Lei, Longhai; Tang, Jun; Zhang, Tianen; Guo, Hao; Li, Yanna; Xie, Chengfeng; Shang, Chenglong; Bi, Yu; Zhang, Wendong; Xue, Chenyang; Liu, Jun
2014-12-20
This paper presents a strain gauge using the mechanical-optical coupling method. The Si-based optical microring resonator was employed as the sensing element, which was embedded on the microcantilevers. The experimental results show that applying external strain triggers a clear redshift of the output resonant spectrum of the structure. The sensitivity of 93.72 pm/MPa was achieved, which also was verified using theoretical simulations. This paper provides what we believe is a new method to develop micro-opto-electromechanical system (MOEMS) sensors.
Orientation selectivity based structure for texture classification
NASA Astrophysics Data System (ADS)
Wu, Jinjian; Lin, Weisi; Shi, Guangming; Zhang, Yazhong; Lu, Liu
2014-10-01
Local structure, e.g., local binary pattern (LBP), is widely used in texture classification. However, LBP is too sensitive to disturbance. In this paper, we introduce a novel structure for texture classification. Researches on cognitive neuroscience indicate that the primary visual cortex presents remarkable orientation selectivity for visual information extraction. Inspired by this, we investigate the orientation similarities among neighbor pixels, and propose an orientation selectivity based pattern for local structure description. Experimental results on texture classification demonstrate that the proposed structure descriptor is quite robust to disturbance.
Collisionless dissociation and isotopic enrichment of SF6 using high-powered CO2 laser radiation
NASA Technical Reports Server (NTRS)
Gower, M. C.; Billman, K. W.
1977-01-01
Dissociation of S-32F6 and the resultant isotopic enrichment of S-34F6 using high-powered CO2 laser radiation has been studied with higher experimental sensitivity than previously reported. Enrichment factors have been measured as a function of laser pulse number, wavelength, energy and time duration. A geometry independent dissociation cross section is introduced and measured values are presented. Threshold energy densities, below which no dissociation was observed, were also determined.
NASA Astrophysics Data System (ADS)
Arregui, Francisco J.; Matias, Ignacio R.; Bariain, Candido; Lopez-Amo, Manuel
1998-06-01
Tapered optical fibers are used to design couplers, wavelength division multiplexers, near field scanning optical microscopy, just to mention a few. Moreover, and due to its strong transmission dependence to external medium the tapered fiber may also be used to sense distinct parameters such as temperature, humidity, PH, etc. In this work bending effects in tapers are exploited to achieved displacement sensors and to present design rules for implementing these sensors according to the desired both range and sensitivity.
High-Sensitive Two-Layer Photoresistors Based on p-Cd x Hg1-x Te with a Converted Near-Surface Layer
NASA Astrophysics Data System (ADS)
Ismailov, N. D.; Talipov, N. Kh.; Voitsekhovskii, A. V.
2018-04-01
The results of an experimental study of photoelectric characteristics of two-layer photoresistors based on p-Cd x Hg1-x Te (x = 0.24-0.28) with a thin near-surface layer of n-type obtained by treatment in atmospheric gas plasma are presented. It is shown that the presence of a potential barrier between the p- and n-regions causes high photosensitivity and speed of operation of such photoresistors at T = 77 K
Simulation of synaptic coupling of neuron-like generators via a memristive device
NASA Astrophysics Data System (ADS)
Gerasimova, S. A.; Mikhaylov, A. N.; Belov, A. I.; Korolev, D. S.; Gorshkov, O. N.; Kazantsev, V. B.
2017-08-01
A physical model of synaptically coupled neuron-like generators interacting via a memristive device has been presented. The model simulates the synaptic transmission of pulsed signals between brain neurons. The action on the receiving generator has been performed via a memristive device that demonstrates adaptive behavior. It has been established that the proposed coupling channel provides the forced synchronization with the parameters depending on the memristive device sensitivity. Synchronization modes 1: 1 and 2: 1 have been experimentally observed.
Transport Test Problems for Hybrid Methods Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaver, Mark W.; Miller, Erin A.; Wittman, Richard S.
2011-12-28
This report presents 9 test problems to guide testing and development of hybrid calculations for the ADVANTG code at ORNL. These test cases can be used for comparing different types of radiation transport calculations, as well as for guiding the development of variance reduction methods. Cases are drawn primarily from existing or previous calculations with a preference for cases which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22.
Contactless ultrasonic device to measure surface acoustic wave velocities versus temperature.
Hubert, C; Nadal, M H; Ravel-Chapuis, G; Oltra, R
2007-02-01
A complete optical experimental setup for generating and detecting surface acoustic waves [Rayleigh waves (RWs)] in metals versus temperature up to the melting point is described. The RWs were excited by a pulsed Nd:YAG laser and detected by a high sensitivity subangstrom heterodyne interferometer. A special furnace was used to heat the sample using infrared radiation with a regulation of the sample temperature less than 0.1 K. First measurements on an aluminum alloy sample are presented to validate the setup.
NASA Astrophysics Data System (ADS)
Vandenboomgaerde, M.; Liberatore, S.; Galmiche, D.; Casner, A.; Huser, G.; Jadaud, J. P.; Villette, B.
2008-05-01
Implosion of inertial confinement fusion (ICF) capsule is very sensitive to the growth of sphericity perturbations. The control of the feeding of such perturbations and their transport ('feedthrough') through the ablator is a key point to reach ignition. Since 2002 [1, 2], experiments have been designed and performed on the Omega laser facility in order to study these phenomena in planar geometry. A new 'rugby shaped' hohlraum was used [3, 4]. We present experimental results and comparisons with numerical simulations.
Nonrotational states in isotonic chains of heavy nuclei
NASA Astrophysics Data System (ADS)
Adamian, G. G.; Malov, L. A.; Antonenko, N. V.; Jolos, R. V.
2018-03-01
The ground-state deformations of heavy nuclei are explored with the microscopic-macroscopic approach using the single-particle Woods-Saxon potential of the quasiparticle-phonon model. The calculations of the energies of low-lying nonrotational states take into account the residual pairing and phonon-quasiparticle interactions. The spectra of these states are presented for the N =147 -161 isotones. The sensitivity of the calculated results to the parameters of the model is studied. A rather good description of the available experimental data is demonstrated.
Distributed measurement of birefringence dispersion in polarization-maintaining fibers
NASA Astrophysics Data System (ADS)
Tang, Feng; Wang, Xiang-Zhao; Zhang, Yimo; Jing, Wencai
2006-12-01
A new method to measure the birefringence dispersion in high-birefringence polarization-maintaining fibers is presented using white-light interferometry. By analyzing broadening of low-coherence interferograms obtained in a scanning Michelson interferometer, the birefringence dispersion and its variation along different fiber sections are acquired with high sensitivity and accuracy. Birefringence dispersions of two PANDA fibers at their operation wavelength are measured to be 0.011 ps/(km nm) and 0.018 ps/(km nm), respectively. Distributed measurement capability of the method is also verified experimentally.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steill, Jeffrey D.; Huang, Haifeng; Hoops, Alexandra A.
This report summarizes our development of spectroscopic chemical analysis techniques and spectral modeling for trace-gas measurements of highly-regulated low-concentration species present in flue gas emissions from utility coal boilers such as HCl under conditions of high humidity. Detailed spectral modeling of the spectroscopy of HCl and other important combustion and atmospheric species such as H 2 O, CO 2 , N 2 O, NO 2 , SO 2 , and CH 4 demonstrates that IR-laser spectroscopy is a sensitive multi-component analysis strategy. Experimental measurements from techniques based on IR laser spectroscopy are presented that demonstrate sub-ppm sensitivity levels to thesemore » species. Photoacoustic infrared spectroscopy is used to detect and quantify HCl at ppm levels with extremely high signal-to-noise even under conditions of high relative humidity. Additionally, cavity ring-down IR spectroscopy is used to achieve an extremely high sensitivity to combustion trace gases in this spectral region; ppm level CH 4 is one demonstrated example. The importance of spectral resolution in the sensitivity of a trace-gas measurement is examined by spectral modeling in the mid- and near-IR, and efforts to improve measurement resolution through novel instrument development are described. While previous project reports focused on benefits and complexities of the dual-etalon cavity ring-down infrared spectrometer, here details on steps taken to implement this unique and potentially revolutionary instrument are described. This report also illustrates and critiques the general strategy of IR- laser photodetection of trace gases leading to the conclusion that mid-IR laser spectroscopy techniques provide a promising basis for further instrument development and implementation that will enable cost-effective sensitive detection of multiple key contaminant species simultaneously.« less
The Study of High-Speed Surface Dynamics Using a Pulsed Proton Beam
NASA Astrophysics Data System (ADS)
Buttler, William; Stone, Benjamin; Oro, David; Dimonte, Guy; Preston, Dean; Cherne, Frank; Germann, Timothy; Terrones, Guillermo; Tupa, Dale
2011-06-01
Los Alamos National Laboratory is presently engaged in development and implementation of ejecta source term and transport models for integration into LANL hydrodynamic computer codes. Experimental support for the effort spans a broad array of activities, including ejecta source term measurements from machine roughened Sn surfaces shocked by HE or flyer plates. Because the underlying postulate for ejecta formation is that ejecta are characterized by Richtmyer-Meshkov instability (RMI) phenomena, a key element of the theory and modeling effort centers on validation and verification RMI experiments at the LANSCE Proton Radiography Facility (pRad) to compare with modeled ejecta measurements. Here we present experimental results used to define and validate a physics based ejecta model together with remarkable, unexpected results of Sn instability growth in vacuum and gasses, and Sn and Cu RM growth that reveals the sensitivity of the RM instability to the yield strength of the material, Cu. The motivation of this last subject, RM growth linked to material strength, is to probe the shock pressure regions over which ejecta begins to form. Presenter
Emitter-site-selective photoelectron circular dichroism of trifluoromethyloxirane
Ilchen, M.; Hartmann, G.; Rupprecht, P.; ...
2017-05-30
The angle-resolved inner-shell photoionization of R-trifluoromethyloxirane, C 3H 3F 3O, is studied experimentally and theoretically. Thereby, we investigate the photoelectron circular dichroism (PECD) for nearly symmetric O 1s and F 1s electronic orbitals, which are localized on different molecular sites. The respective dichroic β 1 and angular distribution β 2 parameters are measured at the photoelectron kinetic energies from 1 to 16 eV by using variably polarized synchrotron radiation and velocity map imaging spectroscopy. The present experimental results are in good agreement with the outcome of ab initio electronic structure calculations. We report a sizable chiral asymmetry β 1 ofmore » up to about 9% for the K -shell photoionization of oxygen atom. For the individual fluorine atoms, the present calculations predict asymmetries of similar size. However, being averaged over all fluorine atoms, it drops down to about 2%, as also observed in the present experiment. Our study demonstrates a strong emitter and site sensitivity of PECD in the one-photon inner-shell ionization of this chiral molecule.« less
NASA Astrophysics Data System (ADS)
Zhao, Yong; Xia, Feng; Hu, Hai-feng; Chen, Mao-qing
2017-11-01
A novel refractive index (RI) sensor based on photonic crystal fiber Mach-Zehnder interferometer (PCF-MZI) was proposed. It was realized by cascading a section of PCF with half-taper collapse regions (HTCRs) between two single mode fibers (SMFs). The relationship between RI sensitivity and interference length of the PCF-MZI was firstly investigated. Both simulation and experimental results showed that RI sensitivity increased with the increase of interference length. Afterwards, influence of HTCR parameters on RI sensitivity was experimentally investigated to further improve the sensitivity. With intensification of arc discharge intensity in HTCR fabrication process, HTCR with larger maximum taper diameter and longer collapsed region length was obtained, which enhanced evanescent field of the PCF-MZI and then generated higher RI sensitivity. Consequently, a high RI sensitivity of 181.96 nm/refractive index unit (RIU) was achieved in the RI range of 1.3333-1.3574. Increasing arc discharge intensity in HTCR fabrication process has the capacity to improve RI sensitivity of PCF-MZI and meanwhile provides higher mechanical strength and longer sensor life compared to the traditional method of tapering the fiber, which improves the RI sensitivity at the cost of reducing mechanical strength of the sensor. This PCF-MZI was characterized by high RI sensitivity, ease of fabrication, high mechanical strength, and robustness.
Modeling off-frequency binaural masking for short- and long-duration signals.
Nitschmann, Marc; Yasin, Ifat; Henning, G Bruce; Verhey, Jesko L
2017-08-01
Experimental binaural masking-pattern data are presented together with model simulations for 12- and 600-ms signals. The masker was a diotic 11-Hz wide noise centered on 500 Hz. The tonal signal was presented either diotically or dichotically (180° interaural phase difference) with frequencies ranging from 400 to 600 Hz. The results and the modeling agree with previous data and hypotheses; simulations with a binaural model sensitive to monaural modulation cues show that the effect of duration on off-frequency binaural masking-level differences is mainly a result of modulation cues which are only available in the monaural detection of long signals.
Nanophotonics: Energy Transfer towards Enhanced Luminescent Chemosensing
Aad, Roy; Couteau, Christophe; Lérondel, Gilles
2015-01-01
We discuss a recently proposed novel photonic approach for enhancing the fluorescence of extremely thin chemosensing polymer layers. We present theoretical and experimental results demonstrating the concept of gain-assisted waveguided energy transfer (G-WET) on a very thin polymer nanolayer spincoated on an active ZnO thin film. The G-WET approach is shown to result in an 8-fold increase in polymer fluorescence. We then extend the G-WET concept to nanostructured media. The benefits of using active nanostructured substrates on the sensitivity and fluorescence of chemosensing polymers are discussed. Preliminary theoretical results on enlarged sensing surface and photonic band-gap are presented. PMID:28788025
NASA Technical Reports Server (NTRS)
Abbas, M. M.; Kostiuk, T.; Ogilvie, K. W.
1975-01-01
The performance of an upconversion system is examined for observation of astronomical sources in the low to middle infrared spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in view of the conversion efficiencies, spectral resolution, field of view, minimum detectable source brightness and source flux. Experimental results of blackbody measurements and molecular absorption spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates of the expected optimum sensitivity of an upconversion device which may be built with the presently available components are given.
Landenberger, Kira B; Bolton, Onas; Matzger, Adam J
2015-04-22
Here we report a series of energetic-energetic cocrystals that incorporate the primary explosive diacetone diperoxide (DADP) with a series of trihalotrinitrobenzene explosives: 1:1 DADP/1,3,5-trichloro-2,4,6-trinitrobenzene (TCTNB), 1:1 DADP/1,3,5-tribromo-2,4,6-trinitrobenzene (TBTNB), and 1:1 DADP/1,3,5-triiodo-2,4,6-trinitrobenzene (TITNB). Acetone peroxides are attractive for their inexpensive and facile synthesis, but undesirable properties such as poor stability, intractably high sensitivity and low density, an indicator for low explosive power, have limited their application. Here through cocrystallization the density, oxygen balance, and stability of DADP are dramatically improved. Regarding sensitivity, in the case of the DADP/TCTNB cocrystal, the high impact sensitivity of DADP is retained by the cocrystal, making it a denser and less volatile form of DADP that remains viable as a primary explosive. Conversely, the DADP/TITNB cocrystal features impact sensitivity that is greatly reduced relative to both pure DADP and pure TITNB, demonstrating for the first time an energetic cocrystal that is less sensitive to impact than either of its pure components. This dramatic difference in cocrystal sensitivities may stem from the significantly different halogen-peroxide interactions seen in each cocrystal structure. These results highlight how sensitivity is defined by complex relationships between inherent bond strengths and solid-state properties, and cocrystal series such as that presented here provide a powerful experimental platform to probe this relationship.
NASA Technical Reports Server (NTRS)
Avery, D. E.
1985-01-01
The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally by using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold wall heating rate data for laminar and turbulent flow were obtained in the Langley 8 foot high Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300R, a free stream unit Reynolds number from 3.4 x 10 sup 5 to 2.2 10 sup 6 per foot, and a free stream dynamic pressure from 2.1 to 9.0 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads. For the conditions of the present study, the results show that localized and total heating are sensitive to changes in flow angle only for the test conditions of turbulent boundary layer flow with high kinetic energy and that a flow angle from 30 deg to 50 deg will minimize the local heating.
Real-time image processing for particle tracking velocimetry
NASA Astrophysics Data System (ADS)
Kreizer, Mark; Ratner, David; Liberzon, Alex
2010-01-01
We present a novel high-speed particle tracking velocimetry (PTV) experimental system. Its novelty is due to the FPGA-based, real-time image processing "on camera". Instead of an image, the camera transfers to the computer using a network card, only the relevant information of the identified flow tracers. Therefore, the system is ideal for the remote particle tracking systems in research and industrial applications, while the camera can be controlled and data can be transferred over any high-bandwidth network. We present the hardware and the open source software aspects of the PTV experiments. The tracking results of the new experimental system has been compared to the flow visualization and particle image velocimetry measurements. The canonical flow in the central cross section of a a cubic cavity (1:1:1 aspect ratio) in our lid-driven cavity apparatus is used for validation purposes. The downstream secondary eddy (DSE) is the sensitive portion of this flow and its size was measured with increasing Reynolds number (via increasing belt velocity). The size of DSE estimated from the flow visualization, PIV and compressed PTV is shown to agree within the experimental uncertainty of the methods applied.
Sun, Chunran; Wang, Muguang; Jian, Shuisheng
2017-08-21
In this paper, a novel quasi-fan Solc structure filter based on elliptical-core spun fiber for twist sensing has been experimentally investigated and theoretically analyzed. The discrete model of spun fiber has been built to analyze the transmission characteristics of proposed sensor. Both experimental and simulated results indicate that the extinction ratio of the comb spectrum based on quasi-fan Solc birefringent fiber filter varies with twist angle and agrees well with each other. Based on the intensity modulation, the proposed twist sensor exhibits a high sensitivity of 0.02219 dB/(°/m). Moreover, thanks to the invariability of the fiber birefringence and the state of polarization of the input light, the proposed twist sensor has a very low temperature and strain sensitivity, which can avoid the cross-sensitivity problem existing in most twist sensors.
NASA Astrophysics Data System (ADS)
Balaji, P. A.
1999-07-01
A cricket's ear is a directional acoustic sensor. It has a remarkable level of sensitivity to the direction of sound propagation in a narrow frequency bandwidth of 4-5 KHz. Because of its complexity, the directional sensitivity has long intrigued researchers. The cricket's ear is a four-acoustic-inputs/two-vibration-outputs system. In this dissertation, this system is examined in depth, both experimentally and theoretically, with a primary goal to understand the mechanics involved in directional hearing. Experimental identification of the system is done by using random signal processing techniques. Theoretical identification of the system is accomplished by analyzing sound transmission through complex trachea of the ear. Finally, a description of how the cricket achieves directional hearing sensitivity is proposed. The fundamental principle involved in directional heating of the cricket has been utilized to design a device to obtain a directional signal from non- directional inputs.
NASA Astrophysics Data System (ADS)
Xie, Nanjie; Zhang, Hao; Liu, Bo; Wu, Jixuan; Song, Binbin; Han, Tingting
2017-11-01
A highly sensitive microfluidic sensor based on a microfiber-assisted Mach-Zehnder interferometer (MAMZI) is proposed and experimentally demonstrated for the detection of low-concentration glucose solution. A segment of microfiber tapered from standard single-mode fiber (SMF) is spliced between two SMFs with pre-designed lateral offset to constitute the miniaturized MAMZI probe. The transmission spectral response to environmental refractive index variation has been experimentally investigated for glucose concentration ranges of 300 mg dL-1 to 3000 mg dL-1 and 0 to 270 mg dL-1 and the glucose concentration detection limit is 3 mg dL-1, and the experimentally observed transmission spectral responses are in accordance with our theoretical simulation results. Owing to its high sensitivity, non-enzymatic operation method, ease of fabrication and compact size, our proposed MAMZI for glucose sensing is anticipated to be employed in biomedical applications.
Hu, Pengbing; Dong, Xinyong; Wong, Wei Chang; Chen, Li Han; Ni, Kai; Chan, Chi Chiu
2015-04-01
We present a simple photonic crystal fiber interferometer (PCFI) that operates in reflection mode for pH measurement. The sensor is made by coating polyvinyl alcohol/polyacrylic acid (PVA/PAA) hydrogel onto the surface of the PCFI, constructed by splicing a stub of PCF at the distal end of a single-mode fiber with its free end airhole collapsed. The experimental results demonstrate a high average sensitivity of 0.9 nm/pH unit for the 11 wt.% PVA/PAA coated sensor in the pH range from 2.5 to 6.5. The sensor also displays high repeatability and stability and low cross-sensitivity to temperature. Fast, reversible rise and fall times of 12 s and 18 s, respectively, are achieved for the sensor time response.
NASA Astrophysics Data System (ADS)
de Andrade, Rocelito Lopes; de Oliveira, Matheus Costa; Kohlrausch, Emerson Cristofer; Santos, Marcos José Leite
2018-05-01
This work presents a new and simple method for determining IPH (current source dependent on luminance), I0 (reverse saturation current), n (ideality factor), RP and RS, (parallel and series resistance) to build an electrical model for dye sensitized solar cells (DSSCs). The electrical circuit parameters used in the simulation and to generate theoretical curves for the single diode electrical model were extracted from I-V curves of assembled DSSCs. Model validation was performed by assembling five different types of DSSCs and evaluating the following parameters: effect of a TiO2 blocking/adhesive layer, thickness of the TiO2 layer and the presence of a light scattering layer. In addition, irradiance, temperature, series and parallel resistance, ideality factor and reverse saturation current were simulated.
NASA Astrophysics Data System (ADS)
Raj, Prasoon; Angelone, Maurizio; Döring, Toralf; Eberhardt, Klaus; Fischer, Ulrich; Klix, Axel; Schwengner, Ronald
2018-01-01
Neutron and gamma flux measurements in designated positions in the test blanket modules (TBM) of ITER will be important tasks during ITER's campaigns. As part of the ongoing task on development of nuclear instrumentation for application in European ITER TBMs, experimental investigations on self-powered detectors (SPD) are undertaken. This paper reports the findings of neutron and photon irradiation tests performed with a test SPD in flat sandwich-like geometry. Whereas both neutrons and gammas can be detected with appropriate optimization of geometries, materials and sizes of the components, the present sandwich-like design is more sensitive to gammas than 14 MeV neutrons. Range of SPD current signals achievable under TBM conditions are predicted based on the SPD sensitivities measured in this work.
Qian, Linyong; Zhang, Dawei; Dai, Bo; Wang, Qi; Huang, Yuanshen; Zhuang, Songlin
2015-07-13
A novel bandwidth-tunable notch filter is proposed based on the guided-mode resonance effect. The notch is created due to the superposition spectra response of two guided-mode resonant filters. The compact, bandwidth tuning capability is realized by taking advantage the effect of spectra-to-polarization sensitivity in one-dimensional classical guided-mode resonance filter, and using a liquid crystal polarization rotator for precise and simple polarization control. The operation principle and the design of the device are presented, and we demonstrate it experimentally. The central wavelength is fixed at 766.4 nm with a relatively symmetric profile. The full width at half maximum bandwidth could be tuned from 8.6 nm to 18.2 nm by controlling the applied voltage in electrically-driving polarization rotator.
NASA Technical Reports Server (NTRS)
Rivers, S. M. B.; Wahls, R. A.; Owens, L. R.
2001-01-01
A computational study focused on leading-edge radius effects and associated Reynolds number sensitivity for a High Speed Civil Transport configuration at transonic conditions was conducted as part of NASA's High Speed Research Program. The primary purposes were to assess the capabilities of computational fluid dynamics to predict Reynolds number effects for a range of leading-edge radius distributions on a second-generation supersonic transport configuration, and to evaluate the potential performance benefits of each at the transonic cruise condition. Five leading-edge radius distributions are described, and the potential performance benefit including the Reynolds number sensitivity for each is presented. Computational results for two leading-edge radius distributions are compared with experimental results acquired in the National Transonic Facility over a broad Reynolds number range.
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aguilar-Arevalo, A.; Amidei, D.; Bertou, X.
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eVmore » $$c^{-2}$$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $$\\kappa$$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$$\\times$$$10^{-14}$$ at 17 eV$$c^{-2}$$. These results are the most stringent direct detection constraints on hidden-photon dark matter with masses 3-12 eV$$c^{-2}$$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.« less
Experimental realization of a metamaterial detector focal plane array.
Shrekenhamer, David; Xu, Wangren; Venkatesh, Suresh; Schurig, David; Sonkusale, Sameer; Padilla, Willie J
2012-10-26
We present a metamaterial absorber detector array that enables room-temperature, narrow-band detection of gigahertz (GHz) radiation in the S band (2-4 GHz). The system is implemented in a commercial printed circuit board process and we characterize the detector sensitivity and angular dependence. A modified metamaterial absorber geometry allows for each unit cell to act as an isolated detector pixel and to collectively form a focal plane array . Each pixel can have a dedicated microwave receiver chain and functions together as a hybrid device tuned to maximize the efficiency of detected power. The demonstrated subwavelength pixel shows detected sensitivity of -77 dBm, corresponding to a radiation power density of 27 nW/m(2), with pixel to pixel coupling interference below -14 dB at 2.5 GHz.